HomeMy WebLinkAbout1302 P St - BuildingElectrical Permit
1302 P St
12 -1541
INSPECTION TYPE
DATE:
RESULTS:
INSPECTOR:
DITCH
SERVICE
ROUGH -IN
it 10 f )2_
ce
1 1 1 1 4 4
FINAL
W3
COMMENTS:
Application Number
Application pin number
Property Address
ASSESSOR PARCEL NUMBER:
Application type description
Subdivision Name
Property Use
Property Zoning
Application valuation
Owner
PA PARTNERS LLC
705 DONOVAN AVE
BELLINGHAM
(360) 303 -8748
Permit
Additional desc
Permit Fee
Issue Date
Expiration Date
Permit Fee Total
Plan Check Total
Grand Total
WA 98225
Fee summary Charged
56.00
.00
56.00
12- 00001541
693007
1302 P ST
06-30-01-8-0- 0150 -0000-
ELECTRICAL ONLY
RS9 RESDNTL SINGLE FAMILY
0
Contractor
ELECTRICAL ALTER RESIDENTIAL
T -STAT
56.00
11/28/12
5/27/13
Qty Unit Charge Per
1.00 56.0000 ECH EL- LVT- THERMOSTAT
56.00
.00
56.00
PERMIT WILL EXPIRE SIX (6) MONTHS FROM LAST INSPECTION
ELECTRICAL PERMIT
CITY OF PORT ANGELES
360 417 -4735
INDOOR COMFORT SYSTEMS INC.
118 VIOLET MEADOWS ST. S.
TACOMA WA 98444
(253) 539 -1424
Plan Check Fee
Valuation
Paid Credited Due
.00
.00
.00
Date 11/28/12
.0 0
0
Extension
56.00
.00
.00
.00
REPORT SALES TAX
on your excise tax form
to the City of Port Angeles
(Location Code 0502)
Signature of owner or Electrical Contractor X Date:
G: \EXCHANGE \BUILDING
CITY OF PORT ANGELES PERMIT APPLICATION
Building Division /Electrical Inspections
321 East Fifth Street P.O. Box 1150 Port Angeles Washington, 98362
Ph: (360) 417-4735 Fax: (360) 417 -4711
Date: l I t 13\1 1 2 Single Family Dwelling
Plan Review May Be Required, Please Cmm.10 Plortrical_Plan Review Information Sheet
Job Address: 130 3 P s� A1\c e s r W.A ci 63ib a
Building Square Footage: I log to
Description of above 1.. .3 \co 4 %t ■.q Ra s, d e,N c
Owner Information
Name: 9 A Vacirers \..:W (Kms
Mailin Address: 10 S D ra-1 Peq e-
City: e\1vri\n State: W A Zip: R 5
Phone: Fax:
License Exp.
Contractor Information
Name: Zr
Mailing Address: tt'?a Cote,*
City: To-c.s State: 1*) Zip: a f% k4 4
Phone: Qs3- S39 -i'Fa4 Fax: X53- cttl
License Exp. o cc-s uo S t 3 t Lt.
Item Unit Charge (3yt
Service /Feeder 200 Amp. 120.00
Service /Feeder 201 -400 Amp. 146.00
Service /Feeder 401 -600 Amp 205.00
Service /Feeder 601 -1000 Amp. 262.00
Service /Feeder over 1000 Amp. 373.00
Branch Circuit W/ Service Feeder 5.00
Branch Circuit W/O Service Feeder 63.00
Each Additional Branch Circuit 5.00
Branch Circuits 1-4 75.00
Temp. Service/ Feeder 200 Amp. 93.00
Temp. Service /Feeder 201 -400 Amp. 110.00
Temp. Service /Feeder 401 -600 Amp. 149.00
Temp. Service /Feeder 601 -1000 Amp 168.00
Portal to Portal Hourly 96.00
Signal Circuit/ Limited Energy -1 2 Family Dwelling 64.00
Manufactured Home Connection 120.00
Renewable Electrical Energy 5KVA System or Less 102.00
Thermostat 56.00
Note: $5.00 for each additional T -Stat
NEW CONSTRUCTION ONLY:
First 1300 Square Ft. 120.00
Each Additional 500 Square Ft. or Portion of 40.00
Each Outbuilding or Detached Garage 74.00
Each Swimming Pool or Hot Tub 110.00
Total (Qty Multiplied by Unit Charge)
Sl 0
SZ,.vv Total
Owner as defined by RCW.19.28.261: (1) Owner will occupy the structure for two years after this electrical permit is finalized. (2) Owner is required
to hire an electrical contractor if above said property is for sale, rent or lease. Permit expires after six months of last inspection.
After reading the above statement, I hereby certify that I am the owner of the above named property or a licensed electrical contractor. I am making
the electrical installation or alteration in compliance with the electrical laws, N.E.C., RCW. Chapter 19.28, WAC. Chapter 296 -46B, The City of Port
Angeles Municipal Code, and Utility Specifications and PAMC 14.05.050 regarding Electrical Permit Applications.
Signature of owner, electrical contractor or electrical administrator: Cash Check
Credit Card
Dated: G 0110112012
Electrical Permit
1302 P St
12 -1498
INSPECTION TYPE
DATE:
.RESULTS:
INSPECTOR:
DITCH
SERVICE
011ie 6,
tfrii 2+
2 /214 6 3
de
�G P
ROUGH -IN
1 k IPP
FINAL
COMMENTS:
Application Number
Application pin number
Property Address
ASSESSOR PARCEL NUMBER:
Application type description
Subdivision Name
Property Use
Property Zoning
Application valuation
Application desc
New home 2236 sqft
Owner
PA PARTNERS LLC
705 DONOVAN AVE
BELLINGHAM
(360) 303 -8748
Permit Fee Total
Plan Check Total
Grand Total
WA 98225
Permit ELECTRICAL NEW RESIDENTIAL
Additional desc 1
Permit Fee 200.00
Issue Date 11/14/12
Expiration Date 5/13/13
Fee summary Charged
200.00
.00
200.00
PERMIT WILL EXPIRE SIX (6) MONTHS FROM LAST INSPECTION
Signature of owner or Electrical Contractor X
G: \EXCHANGE \BUILDING
ELECTRICAL PERMIT
CITY OF PORT ANGELES
360-417-4735
12- 00001498
823686
1302 P ST
06-30-01-8-0- 0150 -0000-
ELECTRICAL ONLY
RS9 RESDNTL SINGLE FAMILY
0
200.00
.00
200.00
Contractor
A/C ELECTRICAL INC
PO BOX 44465
TACOMA
(253) 820-8612
Plan Check Fee
Valuation
Qty Unit Charge Per
1.00 120.0000 ECH EL -R -SQFT FIRST 1300
2.00 40.0000 ECH EL -R -SQFT ADDITIONAL 500
Paid Credited Due
.00
.00
.00
Date 11/14/12
WA 98448
.00
0
Extension
120.00
80.00
.00
.00
.00
REPORT SALES TAX
on your excise tax form
to the City of Port Angeles
(Location Code 0502)
Date:
N
tt\.
DATE:
PERMIT#
I SPECTSR
OWNER
CONTRA OR
A �L ML -E-Cr I e L I mac
A
ADDRESS
ELECTRICAL INSPECTION
WIRING REPORT
417 -4735
APPROVED NOT APPROVED
DITCH
ROUGH IN /COVER
SERVICE
FINAL
CORRECTIONS 1 t s rl�tu 1L'F2
RECTIONS NEEDED: c�
NOTIFY INSPECTOR WHEN CORRECTIONS
ARE COMPLETED WITHIN 15 DAYS
DO NOT REMOVE
/t1A),tu gv__Ou t (1 W.-24A
6r-c. I 7514 LOAD 5117 d An. E_ GFGZ)
62.c JJ'
CITY OF PORT ANGELES PERMIT APPLICATION
Building Division/Electrical Inspections
321 East Fifth Street P.O. Box 1150 Port Angeles Washington, 98362
Ph: (360) 417 -4735 Fax: (360) 417 -4711
Date: ►t /141 1 2 Single Family Dwelling
Plan Review May Be Reguired, Please Complete Electrical Plan Review Information Sheet
Job Address: 130,E r. S4-reef
Building Square Footage: 0236
Description of above mil;, cn 1roC �r
Item
Service/Feeder 200 Amp.
Service/Feeder 201 -400 Amp.
Service/Feeder 401 -600 Amp
Service/Feeder 601 -1000 Amp.
Service/Feeder over 1000 Amp.
Branch Circuit W/ Service Feeder
Branch Circuit W/O Service Feeder
Each Additional Branch Circuit
Branch Circuits 1-4
Temp. Service/ Feeder 200 Amp.
Temp. Service/Feeder 201 -400 Amp.
Temp. Service/Feeder 401 -600 Amp.
Temp. Service/Feeder 601 -1000 Amp
Portal to Portal Hourly
Signal Circuit/ Limited Energy -1 2 Family Dwelling
Manufactured Home Connection
Renewable Electrical Energy 5KVA System or Less
Thermostat
Note: $5.00 for each additional T -Stat
NEW CONSTRUCTION ONLY:
First 1300 Square Ft.
Each Additional 500 Square Ft. or Portion of
Each Outbuilding or Detached Garage
Each Swimming Pool or Hot Tub
Owner Information
Name: K4 k- Thome,
Mailing Address: 1 %O2 P S 4 Lo+ 15
City: rcr-+ fl ein State: Wcr Zip: 'P9362
Phone: Fax:
License Exp
Unit Charge
120.00
146.00
205.00
262.00
373.00
5.00
63.00
5.00
75.00
93.00
110.00
149.00
168.00
96.00
64.00
120.00
102.00
56.00
120.00
40.00
74.00
110.00
Contractor Information
Name: Ale Clef 4444 me
Mailing Address: 1p° 'I4'16M
City: Vicok4x, Zip: e: w r 414V 8
Phone: x53.20 -66/2 Fax
License /Exp. ACaL EX`t61 SF j /7 /2oiy
Total (Qty Multiplied by Unit Charge)
r�cz�
01/01/2012
2tti Total
Owner as defined by RCW.19.28.261: (1) Owner will occupy the structure for two years after this electrical permit is finalized. (2) Owner is required
to hire an electrical contractor if above said property is for sale, rent or lease. Permit expires after six months of last inspection.
After reading the above statement, I hereby certify that I am the owner of the above named property or a licensed electrical contractor.1 am making
the electrical installation or alteration in compliance with the electrical laws, N.E.C., RCW. Chapter 19.28, WAC. Chapter 296 -46B, The City of Port
Angeles Municipal Code, and Utility Specifications and PAMC 14.05.050 regarding Electrical Permit Applications.
Signature of owner, electrical contractor or electrical administrator: Cash Check
91 Credit Card
Applicant Information
Permanent service:
Name and address of party
responsible for permanent
service billing?
Name: ga 1 711,1,1
Street: 1°302 P St red (o1 /S
City State ZIP: po 4 P k k qp n 2.
t
Daytime Phone: Home Phone:
Contact Information
(if other than above)
Name: Title:
Site contact:
Daytime Phone:
Contractor:
Name: i4 /c filer •u, b.c. Company:
Daytime Phone:
Electrician:
Name: 1; K,;.,, Company: A. lc g tec,4,r, .re, ,Tit C
Daytime Phone: 2S 1- 25
Excavator:
Name: Company:
Daytime Phone:
Project Type
Existing New
❑Multi-family residence; of units
IT.Single- family residence
Commercial
Overhead service
Underground service
Project Information
Street address lot number:
❑Subdivision; of lots
❑General service
ElOther:
Description of work: en o r
i302 P s- creel Le+ i5
Nearest cross street:
Desired connection date:
Electrical transformer serving property is: g on a pole on the ground
Electrical Load
sq. ft. Main disconnect size: Zoo amps
Total square footage: 2236
Voltage: K120/240 1ph ❑120/208 3ph ❑277/480 3ph
120/240 3ph 0480 3W 3ph Other
Check all that apply:
No Load Change
Supporting Documentation
ti] Standard residential loads (Lighting, refrigerator, dishwasher, washer)
A/C ton) n Range /Oven Hot Tub
►4 Clothes Dryer n Heating Pumps Hp)
roZI Water Heater Elevator Hp) Other
Please provide a copy of the following:
*Detailed plot plan (.dwg or .dxf format mandatory for subdivisions).
*Electrical one -line drawing showing the service entrance panel and location.
*Connected load data.
*Size and locked rotor amps all otors over 50hp.
Applicant's Signature: Date: JI /y1 /7..
Please complete and return to Public Works Utilities Department
MAIL OR DELIVER COMPLETED FORM TO: 321 E 5TH STREET; PORT ANGELES, WA 98362
FAX TO: 360 417 -4711
Information form.xls
N: \PWKS \LIGHT\ENGR\#Originals \Information form
Electrical Information Form
Public Works Utilities Department (360) 417 -4700
City Electrical inspector (360) 417 -4735
WS
WF
Revised 1 -15 -09
Electrical Permit
1302 P St
12 -1439
INSPECTION TYPE
DATE:
RESULTS:
INSPECTOR:
DITCH
11 ti `)Z
SERVICE
11.)16/17_...
r"1'
q,t e
V
ROUGH -IN
FINAL
iZ he it
qq$1
1�W
COMMENTS:
Owner
Application Number
Application pin number
Property Address
ASSESSOR PARCEL NUMBER:
Application type description
Subdivision Name
Property Use
Property Zoning
Application valuation
Application desc
Underground for service
PA PARTNERS LLC
705 DONOVAN AVE
BELLINGHAM
(360) 303 -8748
Permit
Additional desc
Permit Fee
Issue Date
Expiration Date
WA 98225
Fee summary Charged
ELECTRICAL NEW RESIDENTIAL
120.00
11/01/12
5/29/13
Qty Unit Charge Per
1.00 120.0000 ECH EL -0 -200 SRV FEEDER
Permit Fee Total 120.00
Plan Check Total .00
Grand Total 120.00
PERMIT WILL EXPIRE SIX (6) MONTHS FROM LAST INSPECTION
Signature of owner or Electrical Contractor X
G:\EXCHANGE1BUILDING
ELECTRICAL PERMIT
CITY OF PORT ANGELES
360 417 -4735
12- 00001439 Date 12/14/12
976909
1302 P ST
06-30-01-8-0- 0150 -0000-
ELECTRICAL ONLY
RS9 RESDNTL SINGLE FAMILY
0
120.00
.00
120.00
Contractor
STRAITS ELECTRIC
PO BOX 2914
PORT ANGELES
(360) 452 -9104
Plan Check Fee .00
Valuation
Paid Credited Due
.00
.00
.00
WA 98362
.00
.00
.00
0
Extension
120.00
REPORT SALES TAX
on your excise tax form
to the City of Port Angeles
(Location Code 0502)
Date:
DATE:
ali I 12.7
PERMIT
tZ 14. 9$
INSPECTOR
OWNE
VA
c C r1S 1-4, c,.
CONTRACTOR
L
y 1 e-74- PL
ADDRESS
ELECTRICAL INSPECTION
WIRING REPORT
417 -4735
APPROVED NOT APPROVED
DITCH
ROUGH IN /COVER
SERVICE
FINAL
CORRECTIONS NEEDED: M.1ZTIZR. S 1-4141 L-
Lc,ci W 1 k `T tai 1 E C .f G, tt a1t
612,ia -V1E- VA c.3 iN c_. ?,96 -Lag 2SO t
QU C- 'GE 6,2_ c u tz_gm D c�J LTi j, l t�f
S' im Sly ss_.
NOTIFY INSPECTOR WHEN CORRECTIONS
ARE COMPLETED WITHIN 15 DAYS
DO NOT REMOVE
Electrical Permit
1302 P St
12 -1439
INSPECTION TYPE
DATE:
RESULTS:
INSPECTOR:
DITCH
Gd i Z
SERVICE
ROUGH -IN
FINAL
-W C1 2
1 4 0
1
W
COMMENTS:
Application Number
Application pin number
Property Address
ASSESSOR PARCEL NUMBER:
Application type description
Subdivision Name
Property Use
Property Zoning
Application valuation
Application desc
Underground for service
Owner
PA PARTNERS LLC
705 DONOVAN AVE
BELLINGHAM
(360) 303 -8748
Permit
Additional desc
Permit Fee
Issue Date
Expiration Date
WA 98225
Fee summary Charged
Permit Fee Total
Plan Check Total
Grand Total
ELECTRICAL NEW RESIDENTIAL
120.00
11/01/12
4/30/13
Qty Unit Charge Per
1.00 120.0000 ECH EL -0 -200
120.00
.00
120.00
ELECTRICAL PERMIT
CITY OF PORT ANGELES
360 417 -4735
12- 00001439
976909
1302 P ST
06-30-01-8-0- 0150 -0000-
ELECTRICAL ONLY
RS9 RESDNTL SINGLE FAMILY
0
Contractor
STRAITS ELECTRIC
PO BOX 2914
PORT ANGELES
(360) 452 -9104
Plan Check Fee
Valuation
SRV FEEDER
Paid Credited Due
120.00
.00
120.00
PERMIT WILL EXPIRE SIX (6) MONTHS FROM LAST INSPECTION
.00
.00
.00
Date 11/01/12
WA 98362
Extension
120.00
.00
.00
.00
.00
0
REPORT SALES TAX
on your excise tax form
to the City of Port Angeles
(Location Code 0502)
Signature of owner or Electrical Contractor X
G: \EXCHANGE \BUILDING
Date:
DATED
1
PERMIT
INSPECT
OWNER
CONTRACTOR
G✓ i2p CAS
ADDRESS
/302
s-v-
O• PORT 4,
c' Nair ORKS 6
APPROVED
NOT APPROVED
0/3)/Z., DITCH
ROUGH IN /COVER
SERVICE
FINAL
CORRECTIONS NEEDED:
ELECTRICAL INSPECTION
WIRING REPORT
417 -4735
NOTIFY INSPECTOR WHEN CORRECTIONS
ARE COMPLETED WITHIN 15 DAYS
DO NOT REMOVE
Oct 31 12 01:20p
Straits Electric 3604520741
CITY OF PORT ANGELES PERMIT APPLICATION
Building Division/Electrical Inspections
321 East Fifth Street P.O. Box 1150 Port Angeles Washington, 98362
Ph: (360) 417 -4735 Fax: (360) 417 -4711
Date: C J t
Plan Review MF% Require¢„ P
Job Address: Y
Building Square Footage:
Description of above
Si
PI
Compl te.Electrical Plan Review Information Sheet
Owner Information. P JL4
Name:
Mailing Address:
City: State: Zip:
Phone: Fax:
License #1 Exp,
Item
Service /Feeder 200 Amp.
Service /Feeder 201 -400 Amp.
ServicelFeeder 401.600 Amp
ServicelFeeder 601 -1000 Amp.
Service /Feeder over 1000 Amp.
Branch Circuit W/ Service Feeder
Branch Circuit W10 Service Feeder
Each Additional Branch Circuit
Branch Circuits 1-4
Temp. Service/ Feeder 200 Amp.
Temp. ServicelFeeder 201.400 Amp.
Temp. ServicelFeeder 401 -600 Amp.
Temp. ServicelFeeder 601 -1000 Amp
Portal to Portal Hourly
Signal Circuit/ Limited Energy -1 2 Family Dwelling
Manufactured Nome Connection
Renewable Electrical Energy 5KVA System or Less
Thermostat
Note: S5.00 for each additional T-Stat
NEW CONSTRUCTION ONLY:
First 1300 Square FL
Each Additional 500 Square Ft. or Portion of
Each Outbuilding or Detached Garage
Each Swimming Pool or Hot Tub
Unit Charge
120.00
146.00
205.00
262.00
373.00
5.00
63.00
5.00
75.00
93.00
110.00
149.00
168.00
96.00
64.00
120.00
102.00
56.00
1 2 Single Family Dwelling
Y �-N X\GW` L L
$120.00
40.00 8
74.00
110.00
$_'otal
Owner as defined by RCW.19.28.261: (1) Owner will occupy the structure for two years after this electrical permit is finalized. (2) Owner is required
to hire an electrical contractor if above said property is for sale, rent or lease. Permit expires after six months of last inspection.
After reading e above statement, I hereby certify that I am the owner of the above named property or a licensed electrical contractor. I am making
the electric. •tallation or alteration in compliance with the electrical laws, N. E.C., RCW. Chapter 19.28, WAC. Chapter296 46B, The City of Port
An. -les M L 'al Code, and Utility Specifications and PAMC 14.05.050 regarding Electrical Permit Applications.
nature
ner, electrical contractor or electrical administrator:
Dated:
RECIEVELO
OCT 31, 2012
ELECTICAL
INSPECTIONS
L"a`�T�i�.�l�r'itt
Contractor Information
Name:
Mailing Address:
City: State: Zip:
Phone:
License #lExp. STK -6- c 7 Z eci
Total f u Unit Charge'
Fax:
Cash Check
t Card N
01/0112012
p.1
dre-
Fire Permit
1302 P St
12 -1374
CITY OF PORT ANGELES
FIRE DEPARTMENT PERMIT
321 East 5`' Street, Port Angeles, WA 98362
Application Number 12- 00001374 Date 10/30/12
Application pin number 327296
Property Address 1302 P ST
ASSESSOR PARCEL NUMBER: 06-30-01-8-0- 0150 -0000-
Application type description FIRE SPRINKLER SYSTEM
Subdivision Name
Property Use
Property Zoning RS9 RESDNTL SINGLE FAMILY
Application valuation 3200
Application desc
RESIDENTIAL FIRE SPRINKLER SYSTEM
Owner Contractor
PA PARTNERS LLC
705 DONOVAN AVE
BELLINGHAM
(360) 303 -8748
WA 98225
Permit FIRE SPRINKLER RESIDENTIAL
Additional desc RES. OPEN SPRINKLER SYSTEM
TRU -FLOW SYSTEMS
1551 E MESA VIEW LN
PORT ANGELES WA 98362
(360) 452 -6983
Permit Fee .00 Plan Check Fee
Issue Date 10/30/12 Valuation
Expiration Date 4/28/13
Qty Unit Charge Per Extension
1.00 .0000 ECH FIRE INSPECTION RES SPRINKLER .00
Special Notes and Comments
October 18, 2012 1:57:41 PM Jake Patterson.
Fire Department Required.Inspections:
1. Sprinkler placement prior to sheet rock installation
2. Flow test: minimum 13gpm from 2 most remote heads
3. Alarm bell test
EXTERNAL ALARM BELL REQUIRED. jp
Fee summary
Charged Paid Credited
Due
Permit Fee Total .00 .00 .00 .00
Plan Check Total .00 .00 .00 .00
Grand Total .00 .00 .00 .00
.00
3200
This permit becomes null and void if work authorized is not commenced within 180 days, if work is suspended or
abandoned for a period of 180 days afer the work has commenced, or if required inspections have not been requested with
180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be
true and correct. All provisions of recognized standards, laws and ordinances governing this type of work will be compled
with whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel
the provisions of any state or local law regulating the work specified in the permit.
.gnature of Contractor or Authorized Agent Date Signature of Owner (if Owner is builder) Date
Inspection Type
Date Passed
Comments
FIRE SPRINKLER
Underground piping hydrostatically tested
Underground piping flushed
Interior piping hydrostatically tested
Interior piping inspection
Dry system air tested at 40 psi (24 hours)
Sprinkler final
FIRE ALARM
Rough -in inspection
Alarm final
LP -GAS
Completed by Contractor:
Test #1
Piping pressure test
psi
Underground piping inspection /pressure test
Above ground piping inspection/pressure test
Time initiated
Tank (container) inspection
Test #2
Piping pressure test
psi
Appliance inspection
Time initiated
LP -gas final
UNDERGROUND STORAGE TANK (UST) ABANDONMENT
Removal of flammable /combustible liquids
Tank appropriately abandoned
UST abandonment final
PERMIT OTHER (specify)
permit final
FIRE PERMIT INSPECTION RECORD
Call 360-417-4655 for fire inspections. Please provide a minimum 24 -hour notice. It is unlawful to cover, insulate
or conceal any work before inspected and accepted. Post permit in a conspicuous location.
KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE
GENERAL COMMENTS:
2/15/00
Applicant
Project Business Name
Fire Alarm System
Check all that apply
Fire Sprinkler System
Check all that apply
FIRE-RELATED PERMIT APPLICATION
CITY OF PORT ANGELES
Attn: Building Permit Technician
321 E. Fifth St., Port Angeles, WA 98362
(360) 417 -4815 fax (360) 417 -4711
w "1"
Property Owner A te c y�� Phone
Property Owner's Address )302_ '3
Contractor j L -Ut,) jc.' r 5 Phone
Contractor's Address -7
License /06 Expires )Z'- E -mail ri^� M
PROJECT ADDRESS /3e,
One addressable loop
One zone
Additional .zones
List quantity of additional zones
PROJECT VALUATION (labor materials)
Briefly describe the pro ect:
Installing backflow protection device(s)? /k(4 1- I '114•1707.1 +t- tJ 7
yes ifsno 7 r .5 5
<2 inch water line (list quantity of devices)
>2 inch water line (list quantity of devices)
PROJECT VALUATION (labor materials)
Hood Duct Fire Suppression System
Check all that apply
Will only the fire suppression system be installed or altered?
yes no
Will a hood and /or ductwork be installed or altered?
yes* o no
If yes, a mechanical permit will also be needed.
PROJECT VALUATION (labor materials)
Residential Multi- family Commercial Industrial
Briefly describe the project:
For City Use
Date Received /6 'try
Permit p 74
Phone 3(000
/Residential Multi- family Commercial Industrial
Residential
Commercial
Multi- family
Industrial
Briefly describe the project:
I have read and completed this application and know it to be true and correct. 1 am authorized to apply for this permit and understand
that it is my responsibility to determine what permits are required, and to obtain permits prior to working on projects.
Date/6 Print Name jTl� Signature
T:Forms /Building /Fire related permit application
PREPARED 4/01/13, 12:16:03
PROGRAM BP521L
CITY OF PORT ANGELES
APPLICATION PROPERTY ADDRESS
STRUCTR PERMIT
12 00001374
INSPECTION HISTORY REPORT
0 /00 /00 THRU 0 /00 /00
ASSESSOR PARCEL NUMBER
INSPECTION
1302 P ST 06-30-01-8-0- 0150 -0000-
000 000 FSPK 00 FIRE SPRINKLER RESIDENTIAL FPL 0001 FIRE PLACEMENT
REQ COMM: November 20, 2012 4:0
RES COMM: November 20, 2012 4:10:37 PM jpatters.
000 000 FSPK 00 FIRE SPRINKLER RESIDENTIAL FFLW 0001 FIRE FLOW TEST
REQ COMM: November 20, 2012 4:1
RES COMM: November 20, 2012 4:11:41 PM jpatters.
000 000 FSPK 00 FIRE SPRINKLER RESIDENTIAL FFNL 0001 FIRE FINAL
REQ COMM: March 7, 2013 11:06:4
RES COMM: March 7, 2013 11:07:55 AM- dchastai.
ALTERNATE ID
RESULT DATE /STATUS
063001800150
11/20/12 APPROVED
9:39 PM jpatters.
11/20/12 APPROVED
1:19 PM jpatters.
3/07/13 APPROVED
1 AM dchastai.
PAGE 1
INSPECTOR
JP
JP
DRC
Electrical Permit
1302 P St
12 -1248
INSPECTION TYPE
DATE:
RESULTS:
INSPECTOR:
DITCH
SERVICE
1A2/ I
0
I
ROUGH -IN
FINAL
1/lb hZ-
1.411
COMMENTS:
Application Number 12- 00001248
Application pin number 736032
Property Address 1302 P ST
ASSESSOR PARCEL NUMBER: 06-30-01-8-0- 0150 -0000-
Application type description ELECTRICAL ONLY
Subdivision Name
Property Use
Property Zoning RS9 RESDNTL SINGLE FAMILY
Application valuation 0
Application desc
Temp power pole
Owner
PA PARTNERS LLC
705 DONOVAN AVE
BELLINGHAM
(360) 303 -8748
Permit
Additional desc
Permit Fee
Issue Date
Expiration Date
WA 98225
Fee summary Charged
Permit Fee Total
Plan Check Total
Grand Total
Contractor
ELECTRICAL TEMPORARY SERVICE
93.00
9/25/12
3/24/13
93.00
.00
93.00
93.00
.00
93.00
PERMIT WILL EXPIRE SIX (6) MONTHS FROM LAST INSPECTION
Signature of owner or Electrical Contractor X
G: \EXCHANGE \BUILDING
ELECTRICAL PERMIT
CITY OF PORT ANGELES
360 417 -4735
STRAITS ELECTRIC
PO BOX 2914
PORT ANGELES WA 98362
(360) 452 -9104 45 /514
Plan Check Fee
Valuation
Qty Unit Charge Per
1.00 93.0000 ECH EL -TEMP SRV 0 -200 SRV FDR
Paid Credited
.00
.00
.00
Date 9/25/12
Due
.00
.00
.00
.00
0
Extension
93.00
REPORT SALES TAX
on your excise tax form
to the City of Port Angeles
(Location Code 0502)
Date:
Sep 24 12 09:38a Straits Electric
CITY OF PORT ANGELES PERMIT APPLICATION
Building Division/Electrical Inspections
321 East Fifth Street —P.O. Box 1150 Port Angeles Washington, 98362
Ph: (360) 417 -4735 Fax: (360) 417 4711
Date: 9
a G.
Owner Information
Name: P rPrRTf 1 6-11Z
Mailing Address:
City: State: Zia
Phone: Fax:
License t Exp
Item Unit Charge
ServicelFeeder 200 Amp. S 120.00
Service/Feeder 201 -400 Amp. 146.00
ServicelFeeder 401-600 Amp 205.00
ServicelFeeder 601 -1000 Amp. 262.00
Service/Feeder over 1000 Amp. 373.00
Branch Circuit W/ Service Feeder 5.00
Branch Circuit W/0 Service Feeder 63.00
Each Additional Branch Circuit 5 5.00
Branch Circuits 1-4 75.00
Temp. Service/ Feeder 200 Amp. 93.00
Temp. Service /Feeder 201.400 Amp. 110.00
Temp. Service /Feeder 401.600 Amp. 149.00
Temp. Service/Feeder 601.1000 Amp 168.00
Portal to Portal Hourly 96.00
Signal Circuit/ Limited Energy -1 2 Family Dwelling 64.00
Manufactured Home Connection 120.00
Renewable Electrical Energy 5KVA System or Less 102.00
Thermostat 56.00
Note: $5.00 for each additional T -Stat
NEW CONSTRUCTION ONLY:
First 1300 Square FL $120.00
Each Additional 500 Square Ft. or Portion of 40.00
Each Outbuilding or Detached Garage 74.00
Each Swimming Pool or Hot Tub 5110.00
egi 1 2 Single Family Dwelling
Plan Review Mae Required, PI se Compete Electrical Plan Review Information Sheet
Job Address: O a.
Building Square Footage:
Description of above
�rl�lG�i£��I'T•�IlL4>�1��� lt/�lir�
Contra .1 1.n
Name: ..7". I C.
Mailing dr s: 101P:4� JL
City: State: Zip:
Phone: Fax:
License Exp. 5 J- P
3604520741 p.1
Off. PORT 4.
ELECTRICAL
INSPECTIONS
Total (Qty Multiplied by Unit Chargel
C ��Total
Owner as defined by RCW.1 9.28.261: (1) Owner will occupy the structure for two years after this electrical permit is finalized. (2) Owner is required
to hire an electrical contractor if above said property is for sale, rent or lease. Permit expires after six months of last inspection.
After reading the above statement, I hereby certify that I am the owner of the above named property or a licensed electrical contractor. I am making
the elec ical installation or alteration in compliance with the electrical laws, N.E.C., RCW. Chapter 19.28, WAC. Chapter 296 -46B, The City of Port
ngele. M nicipaf Code, and Utility Specifications and PAMC 14.05.050 regarding Electrical Permit Applications.
Sign: re e f owner, electrical contractor or electrical administrator: Cash Check
Credit Card 1
Dated: q
01 101/201 2
Building Permit
1302 P St
12 -1199
CITY OF PORT ANGELES
DEPARTMENT OF COMMUNITY ECONOMIC DEVELOPMENT BUILDING DIVISION
321 EAST 5TH STREET, PORT ANGELES, WA 98362
Application Number 12- 00001199
Application pin number 646084
Property Address 1302 P ST
ASSESSOR PARCEL NUMBER: 06-30-01-8-0- 0150 -0000-
Application type description RES NEW SFR
Subdivision Name
Property Use
Property Zoning RS9 RESDNTL SINGLE FAMILY.
Application valuation 156668
Application desc
1676 SFR, 440 ATTACHED GAR, 84 SQ PORCH
Owner
PA PARTNERS LLC
705 DONOVAN AVE
BELLINGHAM
(360) 303 -8748
Permit MECHANICAL PERMIT
Additional desc NEW SFR
Permit Fee 97.20
Issue Date 10/01/12
Expiration Date 3/30/13
Permit
Additional desc
Permit Fee
Issue Date
Expiration Date
T:Forms /Building Division /Building Permit
WA 98225
Contractor
Date 10/01/12
TRUE BUILD HOME INC
2522 N PROCTOR PMB 32
TACOMA WA 98406
(253) 272 -5300
Permit BUILDING PERMIT RESIDENTIAL
Additional desc 1676 SQ SFR, 440 SQ GAR, 84 SQ
Permit Fee 1339.45 Plan Check Fee
Issue Date 10/01/12 Valuation
Expiration Date 3/30/13
Qty Unit Charge Per
BASE FEE
57.00 5.6000 THOU BL- 100,001 -500K (5.60 PER K)
Qty Unit Charge Per
BASE FEE
8.00 7.0000 EA PL- PLUMBING TRAP
1.00 7.0000 EA PL -WATER LINE
4.00 7.0000 EA PL -DRAIN VENT PIPING
1.00 15.0000 EA PL -SEWER LINE
870.64
156668
Extension
1020.25
319.20
Plan Check Fee .00
Valuation 0
Qty Unit Charge Per Extension
BASE FEE 50.00
1.00 14.8000 EA ME- FURN /HP /FAU OR 5 TON 14.80
3.00 7.2500 EA ME -VENT FAN (SINGLE DUCT) 21.75
1.00 10.6500 EA ME -HOOD /DUCT -MECH. EXHAUST 10.65
PLUMBING PERMIT
NEW SFR'
163.00 Plan Check Fee .00
10/01/12 Valuation 0
3/30/13
Extension
50.00
56.00
7.00
28.00
15.00
REPORT SALES TAX
on your state excise tax form
to the City of Port Angeles
(Location Code 0502)
Separate Permits are required forelectrical work, SEPA, Shoreline, ESA, utilities, private and public improvements. This permit becomes
null and void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned
for a period of 180 days after the work has commenced, or if required inspections have not been requested within 180 days from the
last inspection. I hereby certify that 1 have read and examined this application and know the same to be true and correct. All provisions
of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does
not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construction.
1 roc,n Sl'eA( fL
Date Print Name Signature of Contractor or Authorized Agent Signature of Owner (if owner is builder)
Inspection Type
Date
Accepted By
Comments
FOUNDATION:
Electrical
Footings
Stemwall
PW Engineering
417 -4831
Foundation Drainage Downspouts
Fire
Piers
417 -4653
Planning
Post Holes (Pole Bldgs.)
417 -4750
PLUMBING:
FINAL Date
Accepted by
Under Floor Slab
Rough -In
Water Line (Meter to Bldg)
Gas Line
Back Flow Water
AIR SEAL:
Walls
Ceiling
FRAMING:
Joists Girders Under Floor
Shear Wall Hold Downs
Walls Roof Ceiling
Drywall (Interior Braced Panel Only)
T -Bar
INSULATION:
Slab
Wall Floor Ceiling
MECHANICAL:
FINAL Date
Accepted by
Heat Pump Furnace FAU Ducts
Rough -In
Gas Line
Wood Stove Pellet Chimney
Commercial Hood Ducts
MANUFACTURED HOMES:
Footing Slab
Blocking Hold Downs
Skirting
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/ USE
SEPA:
ESA:
SHORELINE:
Inspection Type
Date
Accepted By
Electrical
417 -4735
Construction R.W.
PW Engineering
417 -4831
Fire
417 -4653
Planning
417 -4750
Building
417 -4815
PLANNING DEPT. Separate Permit its
SEPA:
ESA:
SHORELINE:
Parking Lighting
Landscaping
T.Cnrmc /RI iId,rr, fli,icinn /Rn ilrlinn Darrnit
BUILDING PERMIT INSPECTION RECORD
PLEASE PROVIDE A MINIMUM 24 -HOUR NOTICE FOR INSPECTIONS
Building Inspections 417 -4815 Electrical Inspections 417 -4735
Public Works Utilities 417 -4831 Backflow Prevention Inspections 417 -4886
IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED
POST PERMIT IN CONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE.
Application Number
Application pin number
Qty Unit Charge Per
1.00 7.0000 EA PL -WATER HEATER
Special Notes and Comments
September 17, 2012 12:59:14 PM rbecker.
If the fire system is a closed system, it will need to have
a double check valve assembly installed. If the fire system
is an open system(vented to the tolet) it will not need a
backflow assembly.
If you have any questions call Ron Becker at 417 -4886,
Fax:452 -4972, or E- mail:rbecker @cityofpa.us
September 17, 2012 4:16:00 PM sroberds.
The permit will result in a new sfr in the RS -11 with lot
'coverage of 18% and site coverage of 23 No land use
issues anticipated.
Electrical load calculations and electrical permits are
required.
Ditches 12" culverts will be installed to City Stanards.
See Public Works Engineering for Standards.
Sanitary sewer connection inspection is required by
Public Works prior to back fill of ditch. 24 hour advance
notice is required. Public Works Inspection request line
417 -4831
Construct driveway to City Standards.
Concrete with exposed aggregate or other non- standard
finishes(including colors or dyes)are not allowed in the
City road right of way. Broom finish only. An inspection by
Public Works Engineering is required prior to pouring
concrete. Public Works inspection request line 417 -4831
September 27, 2012 12:27:40 PM rvess.
All construction work within the City right of way requires
a separate Right of Way Construction application to be
completed by the contractor and approved by Public Works
Engineering prior to the start of work.
Other Fees
Fee summary
Permit Fee Total
Plan Check Total
Other Fee Total
Grand Total
T:Forms /Building Division /Building Permit
CITY OF PORT ANGELES
DEPARTMENT OF COMMUNITY ECONOMIC DEVELOPMENT BUILDING DIVISION
321 EAST 5TH STREET, PORT ANGELES, WA 98362
12- 00001199
646084
RES UNDERGRND SERVICE FEE
MILW DRIVE ASSESSMENT
SEWER SYSTEM DELV CHARGE
STATE SURCHARGE
PW WATER SYSTEM USE FEE
Charged Paid Credited
1599.65 1599.65 .00
870.64 870.64 .00
5534.50 5534.50 .00
8004.79 8004.79 .00
Page 2
Date 10/01/12
Extension
7.00
770.00
240.00
2260.00
4.50
2260.00
Due
.00
.00
.00
.00
REPORT SALES TAX
on your state excise tax form
to the City of Port Angeles
(Location Code 0502)
Separate Permits are required for electrical work, SEPA, Shoreline, ESA, utilities, private and public improvements. This permit becomes
null and void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned
for a period of 180 days after the work has commenced, or if required inspections have not been requested within 180 days from the
last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions
of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does
not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construction.
Date Print Name Signature of Contractor or Authorized Agent Signature of Owner (if owner is builder)
Inspection Type
Date
Accepted By
Comments
FOUNDATION:
Electrical
Footings
Stemwall
PW Engineering
417 -4831
Foundation Drainage Downspouts
Fire
Piers
417 -4653
Planning
Post Holes (Pole Bldgs.)
417 -4750
PLUMBING:
Building
Accepted by
Under Floor Slab
Rough -In
Water Line (Meter to Bldg)
Gas Line
Back Flow Water
FINAL Date
AIR SEAL:
Walls
Ceiling
FRAMING:
Joists Girders Under Floor
Shear Wall Hold Downs
Walls Roof Ceiling
Drywall (Interior Braced Panel Only)
T -Bar
INSULATION:
Slab
Wall Floor Ceiling
MECHANICAL:
FINAL Date
Accepted by
Heat Pump Furnace FAU Ducts
Rough -In
Gas Line
Wood Stove Pellet Chimney
Commercial Hood Ducts
MANUFACTURED HOMES:
Footing Slab
Blocking Ho g 8 Hold Downs
Skirting
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/ USE
SEPA:
ESA:
SHORELINE:
Inspection Type
Date
Accepted By
Electrical
417 -4735
Construction R.W.
PW Engineering
417 -4831
Fire
417 -4653
Planning
417 -4750
Building
417 -4815
PLANNING DEPT. Separate Permit #s
SEPA:
ESA:
SHORELINE:
Parking Lighting
Landscaping
T•rnrrno /Ps ,ibiinn flivic innI iI Jinn Pormi4
BUILDING PERMIT INSPECTION RECORD
PLEASE PROVIDE A MINIMUM 24 -HOUR NOTICE FOR INSPECT IONS
Building Inspections 417 -4815 Electrical Inspections 417 -4735
Public Works Utilities 417 4831 Backflow Prevention Inspections 417 -4886
IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED
POST PERMIT IN CONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE.
i
Application Number
Application pin number
Property Address
ASSESSOR PARCEL NUMBER:
Application type description
Subdivision Name
Property Use
Property Zoning
Application valuation
Application desc
1676 SFR, 440 ATTACHED GAR, 84 SQ PORCH
Owner
PA PARTNERS LLC
705 DONOVAN AVE
BELLINGHAM
(360) 303 -8748
Permit
Additional desc
Permit Fee
Issue Date
Expiration Date
Qty Unit Charge Per
T: Forms /Building Division /Public Works Permit
WA 98225
12- 00001199
646084
1302 P ST
06-30-01-8-0- 0150 -0000-
RES NEW SFR
RS9 RESDNTL SINGLE FAMILY
156668
DRIVEWAY INSTALLATION
180.00
10/01/12
3/30/13
BASE FEE
CITY OF PORT ANGELES
PUBLIC WORKS UTILITIES
321 EAST 5TH STREET, PORT ANGELES, WA 98362
Contractor
TRUE BUILD HOME INC
2522 N PROCTOR PMB 32
TACOMA WA 98406
(253) 272 -5300
Plan Check Fee
Valuation
Permit PUBLIC WORKS RES WATER SERV
Additional desc 3/4" DROP IN METER
Permit Fee 420.00 Plan Check Fee
Issue Date 10/01/12 Valuation
Expiration Date 3/30/13
Special Notes and Comments
September 17, 2012 12:59:14 PM rbecker.
If the fire system is a closed system, it will need to have
a double check valve assembly installed. If the fire system
is an open system(vented to the tolet) it will not need a
backflow assembly.
If you have any questions call Ron Becker at 417 -4886,
Date 10/01/12
.0 0
0
Extension
180.00
.00
156668
Qty Unit Charge Per Extension
1.00 420.0000 EA PW WATER METER DROP IN 420.00
Permit SANITARY SEWER HOOK UP
Additional desc
Permit Fee 150.00 Plan Check Fee .00
Issue Date 10/01/12 Valuation 156668
Expiration Date 3/30/13
Qty Unit Charge Per Extension
1.00 150.0000 EA SAN SEWER HOOKUP 150.00
REPORT SALES TAX
on your state excise tax form
to the City of Port Angeles
(Location Code 0502)
Separate Permits are required for electrical work, SEPA, Shoreline, ESA, utilities, private and public improvements. This permit becomes
null and void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned
for a period of 180 days after the work as commenced, or if required inspections have not been requested within 180 days from the last
inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of
laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not
presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construction.
Signature of Contract •r or Authorized Agent Date
Signature of Owner (if owner is builder) Date
INSPECTION TYPE
DATE
ACCEPTED
COMMENTS
YES I NO
PW UTILITIES (Engineering Division)
WATERLINE METER
SEWER CONNECTION
SANITARY
STORM
SITE DRAINAGE
SITE EROSION CONTROL
PARKING
SIDEWALK
CURB GUTTER
DRIVEWAY APPROACH
BACK -FLOW DEVICE
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY /USE
RESIDENTIAL
DATE
YES
NO
COMMERCIAL
DATE
ACCEPTED..
YES
NO
CONSTRUCTION R.W. PW/
ENGINEERING 417 -4807
CONSTRUCTION R.W.
PW ENGINEERING
FIRE 417 -4653
FIRE DEPT.
PLANNING DEPT. 417 -4750
PLANNING DEPT.
BUILDING 417-
4815
BUILDING
PERMIT INSPECTION RECORD
CALL 417 -4831 FOR UTILITY INSPECTIONS. PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAWFUL TO CO
INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT IN A CONSPICUOUS LOCATION.
KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE
T:Forms /Building Division /Public Works Permit
r m, ORT,
ALA
Application Number
Application pin number
Special Notes and Comments
Fax:452 -4972, or E- mail:rbecker @cityofpa.us
September 17, 2012 4:16:00 PM sroberds.
The permit will result in a new sfr in the RS -11 with lot
coverage of 18% and site coverage of 230. No land use
issues anticipated.
Electrical load calculations and electrical permits are
required.
Ditches 12" culverts will be installed to City Stanards.
See Public Works Engineering for Standards.
Sanitary sewer connection inspection is required by
Public Works prior to back fill of ditch. 24 hour advance
notice is required. Public Works Inspection request line
417 -4831
Construct driveway to City Standards.
Concrete with exposed aggregate or other non standard
finishes(including colors or dyes)are not allowed in the
City road right of way. Broom finish only. An inspection by
Public Works Engineering is required prior to pouring
concrete. Public Works inspection request line 417 -4831
September 27, 2012 12:27:40 PM rvess.
All construction work within the City right of way requires
a separate Right of Way Construction application to be
completed by the contractor and approved by Public Works
Engineering prior to the start of work.
Other Fees
Fee summary Due
Permit Fee Total
Plan Check Total
Other Fee Total
Grand Total
Separate Permits are required for electrical work, SEPA, Shoreline, ESA, utilities, private and public improvements. This permit becomes
null and void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned
for a period of 180 days after the work as commenced, or if required inspections have not been requested within 180 days from the last
inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of
laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not
presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construction.
Signature of Contractor or Authorized Agent Date Signature of Owner (if owner is builder) Date
T:Forms /Building Division/Public Works Permit
CITY OF PORT ANGELES
PUBLIC WORKS UTILITIES
321 EAST 5TH STREET, PORT ANGELES, WA 98362
12- 00001199
646084
RES UNDERGRND SERVICE FEE
MILW DRIVE ASSESSMENT
SEWER SYSTEM DELV CHARGE
STATE SURCHARGE
PW WATER SYSTEM USE FEE
Charged Paid Credited
750.00 750.00 .00
.00 .00 .00
5534.50 5534.50 .00
6284.50 6284.50 .00
Page 2
Date 10/01/12
770.00
240.00
2260.00
4.50
2260.0.0
.00
.00
.00
.00
REPORT SALES TAX
on your state excise tax form
to the City of Port Angeles
(Location Code 0502)
INSPECTION TYPE
DATE
ACCEPTED
COMMENTS
YES NO
PW UTILITIES (Engineering Division)
WATERLINE METER
SEWER CONNECTION
SANITARY
STORM
SITE DRAINAGE
SITE EROSION CONTROL
PARKING
SIDEWALK
CURB GUTTER
DRIVEWAY APPROACH
BACK -FLOW DEVICE
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY /USE
RESIDENTIAL
DATE
YES
NO
COMMERCIAL
DATE
ACCEPTED
YES
NO
CONSTRUCTION R.W. PW/
ENGINEERING 417 -4807
CONSTRUCTION R.W.
PW ENGINEERING
FIRE 417 -4653
FIRE DEPT.
PLANNING DEPT. 417 -4750
PLANNING DEPT.
BUILDING 417-
4815
BUILDING
PERMIT INSPECTION RECORD
CALL 417 -4831 FOR UTILITY INSPECTIONS. PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAWFUL TO CO
INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT IN A CONSPICUOUS LOCATION.
T:Forms /Building Division /Public Works Permit
KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE
Contact person: 1✓t c r S r i =nl R-
Phone: 3 roo SinS (0Z,
Property owner:
14 117 1 rho f`+\.aS I' P- FARcrAl S 1 -L-C. Phone: 3 Goo -30'3- tZ 1 cb
Property owner's'mailing address:
7c..- s o,Jo.i AJg 1... WI\ `1 )622 -5
o Industrial
o Multi- family
Project Business Name:
(for commercial, industrial, or multi family protects)
Contractor's business name: --nix) 3v+ i. c No
(or property owners name if he /she is doing /overseeing the work)
Phone:
253- 1,-71,-
5
3
1
Contractors mailing address:
2 522 Pi- c R yr.)s32_, TAc N`F\ WA 1 a4oto
Lot
Contractor's L &I license number:
LC,- ctZV E- l5 sSY192 -5 c fl
Expiration date:
2 1 i 1
Project Address:
1302 P s
Project Type: 114 Residential o Commercial
o Industrial
o Multi- family
Project Business Name:
(for commercial, industrial, or multi family protects)
Zoning:
7-5- l 1
Parcel
0 co3 b ei B0dJ6000aO
Lot
BUILDING PLUMBING MECHANICAL PERMIT APPLICATION LONG FORM
(To be used for projects that require plan review.)
Please print in ink.
City of Port Angeles
Attn: Building Permit Technician
321 E. 5 St., Port Angeles, WA 98362
360 417 -4815 fax: 360- 417 -4711 Credit card payments are accepted Mon -Fri 8 -5 pm (no Am;' an Express)
Hours: Mon through Fri 8 5 pm Cash checks are accepted Mon -Thurs 8:30 -4 pm Fri 8:30 -12:30 pm
Complete. only the portions of this permit that are relevant to your project.
Date Rece
Permit
Date Appr
Approved b
*If an architect or engineer drew the plans or calculations, include at least one "wet stamped" set of plans
and /or calculations.
T:Forms/Building Division /Building/Plumbing/Mechanical Permit Application Long Form (Revised 2011)
Page 1 of 4
17
Pay the plan check fee .(based on the valuation of the project) at the time of submittal
Residential Pyojects submit:
(1) Two sets of plans* (including engineering calcs, geotech reports, etc. if applicable)
Prescriptive Approach Simple Form (confirming conformance to the Energy Code)
Commercial Projects submit:
Three sets of plans* (including engineering calcs, geotech reports, etc. if applicable)
Paperwork confirming conformance to the Energy Code
For large projects, a pre construction meeting with various City department
personnel is highly recommended, To schedule a pre construction meeting,' contact
the Planning Manager at (360) 417 -4750.
Additional information may need to be submitted including:
landscape plan, parking plan (including ADA spaces, ramps; etc.), utilities
(existing proposed), curbs, sidewalks, storm water.plan, etc.
For Additions New Structures also submit:
Site plan (8 1/2" x 11 showing all structures (existing proposed), setbacks, new driveways
A
Repair /Solar Panels Miscellaneous: (explain the project) N) A
Remodel: (explain the project, includin how the building space is currently being used and what the new,
remodeled use will be) J-rk
Project Valuation
If the space will change from commercial to residential, submit:
"Checklist Converting Commercial Space into Residential Space'
Addition: (explain the project and complete submit page 3) Ni J A
Maximum height of the new addition feet Project Valuation
New Structure: (explain the proiect and complete submit page 3)
11 I (p1lo SF 514 c F-NM 1-.L_111(x, VJ 1T43
A— c ccCk L4 v sr- G, G. A w!J c, st-re. c,g_iaf)
Ar D CsAc -Tzc
Maximum height of the new structure c p feet Project Valuation 1 SLn
PLUMBING PERMIT: Will there be ANY plumbing changes (items moved, added, replaced, or altered)
Check one:
No Yes Xi If yes, complete submit page 4 "Plumbing Changes"
MECHANICAL PERMIT:: Will there be ANY mechanical changes (items moved, added, replaced, or altered)
Check one:
No Yeses_ V If yes, complete submit page 4 "Mechanical Changes"
Will a lawn sprinkler system be installed?
Will a fire sprinkler system be installed?
Project Valuation
Occupancy group of bedrooms 3
Occupant load of full baths Z
Construction type of half baths QS
*Homeowner: If you will be doing overseeing the work, then the project valuation will be determined by doubling the
cost of materials, to reflect the value the repair adds to your props
Cost of materials x 2 Project Valuation rA
1 have read and completed this application and know it to be true and correct l am authorized to apply for this permit
and understand that it is my responsibility to determine what permits are required, and to obtain permits prior to
working on projects.
Date 9 t■ iz Signature
Print Name
Page 2 of 4
Floor Areas
Basement x
1st Floor
2 Floor
3 Floor
Garage
Carport
Covered Porch
Deck
30" high)*
Deck
(5 30" highe
Shed
Other
Other
*Walking surface of the deck above ground
For residential building projects the minimum square foot valuation we accept is:
Dwelling $85.00 per sq. ft. garage /utility/misc.structure $30.00 per sq. ft. porch /deck/carport $12.00 per sq. ft.
Lot coverage is the amount or percent of ground area on which buildings are located.
It includes: houses, garages, carports, covered patios, cantilevered portions of buildings, roof overhangs that are longer
than 30- inches, uncovered decks or porches having walking surfaces higher than 30- inches off the ground, etc.
Total footprint of structures 2 sq. ft. lot size IZ ,213 sq.ft. Lot coverage
Site Coverage is the amount of impervious surface on a parcel, including structures, paved driveways, sidewalks,
patios, and other impervious surfaces. (see Port Angeles Municipal Code 17.94.135 for exemptions)
Does the project include a new driveway? 'Ayes no
If yes, what will the driveway be made of? cement asphalt gravel other
(NOTE: 18 feet is the recommended minimum driveway length for residential projects)
Does this project include a new parking pad? yes A no
If yes, what will the parking pad be made of? o cement asphalt gravel other
Page 3 of 4
Existing square New square Price per new
footage footage square foot
LOT COVERAGE SITE COVERAGE
Remodel project valuation
TOTAL VALUATION
a) Total footprint of structures 2. ,Z0c..) sq. ft. (existing new)
b): Total concrete, asphalt, other impervious surfaces (o sq. ft. (existing new)
c) Add lines "a" "b" above to get the total impervious 2... sq. ft. (existing new)
Total impervious sq. ft. .Iot It 2tt' sq. ft. Site coverage? A
PLUMBING CHANGES
Check "No" or "Yes" (and enter quantities) for each line item.
Type
Sink (hand, mop, floor etc.)
Toilet
Bathtub
Shower
Washing Machine
Hot Water Heater
Water Line (meter to structure)
Re -plumb the structure
Sewer Line
Backflow Prevention Device Types:
Beverage Machine
Landscape Watering System
Fire Sprinkler System 5 2 inch line
Fire Sprinkler System 2 inch line
Plumbing Changes (Moved, Added, Replaced,
or Altered
No )o Yes _3 Quantity
No )C Yes 2- Quantity
No X Yes 2 Quantity
X No Yes Quantity
No X Yes J Quantity
No is Yes 1. Quantity
No )d Yes 1 Quantity
No )C Yes Quantity
No k Yes Quantity
No Yes Quantity
X No Yes Quantity
No Yes Quantity
)�_No Yes Quantity
Please f all other planned plumbing changes or additions that aren't listed above.
MECHANICAL CHANGES
Check "No" or "Yes" (and enter quantities) for each line item.
Tyne 'Mechanical Changes
Furnace, heat pump, or
forced air unit 5 5 tons No Yes
Furnace, heat pump, or
forced air unit 5 tons k No Yes
Ductless heat pump "l No Yes
Wall (recessed) heater No Yes
Baseboard heater )c No Yes
Steffes room heater x No Yes
Wood- burning stove X No Yes
Pellet stove _s No Yes
Radiant floor heat ,__,K_No Yes
Gas fireplace or freestanding stove No Yes
Gas cooking stove X No Yes
Propane tank set k No Yes
Gas line A No Yes
Boiler N No Yes
Clothes Dryer No 4 Yes
Ventilation fan (single duct) No k Yes
Hood &duct mechanical exhaust No k'- Yes
Ventilation system (not part of a heating or air
conditioning system) X No Yes
Air handler k No Yes
Evaporative cooler (non portable) x No Yes
Please list all other planned mechanical changes or additions that aren't listed above.
CIA
Page 4 of 4
(Moved, Added, Replaced,
or Altered
I Quantity
Quantity
Quantity
Quantity
Quantity
Quantity
Quantity
Quantity
Quantity
Quantity
Quantity
Quantity
Quantity
Quantity
Quantity
.43 Quantity
Quantity
Quantity
Quantity
Quantity
s
L� F
5
..e,3":
TIGHTLINE TIED TO
e DOWNSPOUTS
N. o FrG DRAIN
0
0
N N, .Q
WATER LINE
ELECTRICAL
PA PARTNERS
LLC
705 DONOVAN AVE
BELLINGHAM, WA 98225
EXISTING
DRAINAGE SWALE
SITE PLAN
CULVERT
JUAN de FUCA BLUFFS
1302 P STREET
PORT ANGELES, WA 98363
CONC
DRIVE
SIDEWALK
SCALE: 1" 30' -0"
A
SITE PLAN
Al
Option
Glazing
:Area
Glazing U- Factor
Door
Vaulted
Wall
Wall
Interior
W al
E)tterlor
Slab en
F oor..
Vertical
Overhead
Factor
Ceiling
Ceiling
Grade`
Below
Grade
Bellow
Grade
Concrete
R-49
III
Unlimited
0.30
0.50
0,20
or
R -38
R -21
R -21
R -10
R -301
R -10
R 38
adv
int
TB
U =0.029
2'
CRY GOVERNMENT
Lot:
Site Information:
Address: 130 z 5 rQtW.T
City: Pat -T 04dc., �5
State: v/.p Zip: °1 1)3(23
Contact: To 1:›D 5 PE7�C IL
Phone: 3(00 S1 (02(0
Phone 2: 3.
FAX: n) I
WSEC Table 6 -1
PRESCRIPTIVE REQUIREMENTS. FOR SINGLE FAMILY RESIDENTIAL OR DUPLEX
CLIMATE ZONE 1
(Unlimited Glazing Option Only)
This Project complies with the following:
The project is. single family residence or duplex.
11 The project is a wood frame OR all of the insulation is interior or exterior of the framing.
4 All building components meet the requirements listed above.
4 The project will meet all other provisions of the WSEC and VIAQ.
The Project will take advantage of the following exceptions to the prescriptive option.
602.6 Exception 2. One unlabeled or untested exterior swinging door, 24 sq.ft. or less, may be
installed per unit for ornamental, security, or architectural purposes.
Location of the door taking this exception:
602.6 Exception 2. If a door is mostly glass, it should meet the requirement of the vertical
glazing U- factor listed above.
Location of the door(s) taking exception:
Type of Heat Source:
T:Forms/Building Division/Prescriptive Approach Simple Form
?R S RJPTWE APPROACH- SIMPLE FORM
For the Washington State Energy Code (WSEC) 2009 Edition
Climate Zone 1
Building Department Use Only:
Permit
Notes:
SITE CRITERIA
DESIGN
ROOF SNOW
LOAD
WIND
SPEED
(MPH)
WIND
EXPOSURE
(IBC) SEISMIC
DESIGN
CATEGORY
SOIL
PROFILE
OCCUPANCY
CATEGORY
30 PSF
100 MPH
D
D
D
11
SLOPE
PER
OWNER
SPECIAL SITE
CONDITIONS
PER OWNER
GEOTECH
REPORT PER
OWNER
SEISMIC
SPECTRAL
RESPONSE Si
SEISMIC
SPECTRAL
RESPONSE Ss
MULTIPLE
SITES
<15%
NONE
NONE
0.500g
1.163g
NO
2009 IBC LATERAL ANALYSIS AND
GRAVITY LOAD ENGINEERING
FOR: TRUE BUILT HOMES
PLAN: THOMAS WINDAM HILL
SITE:
LOT 15 JUAN DE FUCA BLUFFS
PORT ANGELES, WA 98362
TRUSS MANUFACTURER SHOP
DRAWINGS PROVIDED FOR
ENGINEERING REVIEW: NONE
SINGLE SITE ENGINEERING
THIS ENGINEERING IS FOR
THE SITE AND CONDITIONS LISTED ABOVE ONLY
FILE
PROJECT NUMBER
John Hodge, P.E
2615 Jahn Ave. N.W.
Suite E5
Gig Harbor,WA 98335
Phone: (253) 857 -7055
Fax (253)857 -7599
12.0494
DATE
9.18.12
ORIGINAL STAMP MUST
BE RED TO BE VALID
I
I I I
1 I I
CoPrRGHT020@
HGDGE ENGINEERING. DJC.
DO NOT ACCEPT FOR PERMIT
UNLESS AN ORIGINAL RED SEAL
DO NOT ACCEPT COPY
1 of 34
Hodge
engineering inc.
Engineering Calculations Package
For Plans Examiner
This engineering calculations package contains lateral engineering, gravity load engineering, or
both as stated on the cover and full size engineering sheets. All engineered load bearing
structural members are shown on the full size engineering sheets. The enclosed engineering
calculations document the analysis used. The engineering calculations are not required to be
referenced for construction. These calculations are to demonstrate to the plans examiner that
the engineering was completed following the 2009 IBC. The cover sheet of the engineering
specifies the engineering scope as lateral engineering, gravity load engineering, or both.
Lateral engineering involves determining what the seismic and wind loads are, applying these
loads to the structure, and determining the design of the lateral structural elements to resist
these loads. These structural elements are sheathing, nailing, holdowns, and connections
between loaded members and shear resisting elements.
LATERAL ENGINEERING: Lateral load modeling was completed with Wood Works Design
Office 8 (www.woodworks•software.com 800 844 1275). Wood Works was developed in
conjunction with the American Forest Paper Association. The AF &PA is the same
professional organization that produces the National Design Specification (NDS) for Wood
Construction, the Allowable Stress Design (ASD) manual for engineered wood construction,
Wood Frame Construction Manual (WFCM) for one -and two- family dwellings, and the Load and
Resistance Factor Design (LFRD) manual for engineered wood construction.
Seismic: Seismic load engineering follows the ASCE 7 -05 equivalent lateral force procedure.
Per ASCE 7 the analysis consists of the application of equivalent static lateral forces to a linear
mathematical model of the structure. The total forces applied in each direction are the total
base shear. Refer to ASCE 7 -05 for a description of this procedure. The engineering
calculations include a USGS determination of the seismic spectral response accelerations.
These numbers, S and Ss, are used in the lateral model to determine seismic loading to the
shearwalls. Woodworks Design Office was used to make the linear mathematical model.
Wind: Wind load engineering follows the ASCE 7 -05 general analytic method for all buildings.
The wind loading is determined from the wind exposure and wind speed. This loading is applied
to surfaces of the structure as modeled. Total loadings for each shear line, wall line, and full
height shearwall are determined. Required shear strength for each shearwall is calculated then
sheathing and nailing patterns are chosen to resist design loads. Holdowns are applied where
the nailing of the sheathing to the mudsill or lower floor is not adequate to resist shear panel
overturning.
GRAVITY LOAD ENGINEERING: If included in the scope of engineering gravity loads from
snow, structure, occupants, etc. meeting the requirements of the 2009 IBC have been traced
through the structure. See the legend on the engineering sheets showing how the point and line
loads are depicted. All loads are supported and traced through the structure. Load supporting
members have been numbered and calculated. Calculations for each beam are included. Post
and column calculations for typical members are also included. Loads to the foundation or soil
have reinforced footings where required.
Every attempt has been made to make the engineering calculations and specifications as clear
as possible.for the plans examiner, builder, and building inspector.
2 of 34
�:l:t ,S f`:�pa'tJiGt;ini�ni
.1;3 7E76,%o'
(S aII 91 Cim)
3 of 34
Conterminous 48 States
2003 NEHRP Seismic Design Provisions
Latitude 47.950659
Longitude 123.345607
Spectral Response Accelerations Ss and S1
Ss and S1 Mapped Spectral Acceleration Values
Site Class B Fa 1.0 ,Fv 1.0
Data are based on a 0.01 deg grid spacing
Period Sa
(sec) (g)
0.2 1.163 (Ss, Site Class B)
1.0 0.500 (S1, Site Class B)
Conterminous 48 States
2003 NEHRP Seismic Design Provisions
Latitude 47.950659
Longitude 123.345607
Spectral Response Accelerations Ss and S1
Ss and S1 Mapped Spectral Acceleration Values
Site Class B Fa 1.0 ,Fv 1.0
Data are based on a 0.01 deg grid spacing
Period Sa
(sec) (g)
0.2 1.163 (Ss, Site Class B)
4 of 34
LATERAL ANALYSIS.wsw
Level 1 of 1
N
m:
N
N;
WoodWorks® Shearwalls
SOFTWARE FOR WOOD DESIGN
148.4
98.4-- 187 5- 187,5 -102.8
Factored shearline force (Ibs) 1 t t 1
Factored holddown force (Ibs)
C Compression force exists 0
Vertical element required
Loads Shown: W; Forces: W 1.0D.
48.
70 o
N
AN Nr
-D-2 -'o
s 6'
48:
ammmimmor
7 6 00 o
4.8 98% 98. a ..6 98.4 98:4
98.4 156.0.1 100.6
Unfactored applied shear load (plf)
Unfactored dead load (plf,lbs)
Uplift wind load (plf,lbs)
Applied point load or discontinuous shearline force (Ibs)
0.2
.4
Sep. 6, 2012 16:56:29
n
to
co
m_.. 47' 6"
N
v _.._45'
42'_6"
-40'
..37' 6"
35'
-32' 6"
30'
27' 6"
co
25'
22' 6"
0
0
0
5 of 34
70'
67' 6"
65'
62' 6"
60'
57' 6"
55'
52' 6"
50'
20'
17' 6"
m
15'
12' 6"
10'
7' 6"
5'
2' 6"
0'
-2' 6"
-5'
-7' 6"
-10'
-12' 6"
-17'6
-20'
22'.6
-25'
11512' 6- 10' -7' 6 -5' -2', 0' 2' 6" 5' 7' 6" 10'12' 6 '15'17' 6'2022' 62527' 6'30'32' 625'37' 6'40'42' 6'45'47' 6'5052' 6'55'57' 6'60'62' 6'6667' 6'70'
Design Code Wind Standard Seismic Standard
IBC 2009 ASCE 7 05 All heights ASCE 7 05
Wind Capacity Increase
Shear C &C Panels
1.40 1.60
Load Combinations
0.70 Seismic
1.00 Wind
Building Code Capacity Reduction
Wind Seismic
1.00 1.00
Nail Withdrawal Modification
Duration Temperature Moisture Content
Factor Range Fabrication Service
1.60 T< =100F =19% =19%
Max Shearwall Offset [ft]
Plan Elevation
(within story) (between stories)
4.00
Maximum Height -to -width Ratio
Wood panels Fiberboard Lumber Gypsum
Wind Seismic Wind Seismic Blocked Unblocked
3.5 3.5
Ignore non wood -panel shear resistance contribution...
Wind Seismic
Never Always
Collector forces based on...
Hold -downs Applied loads
Drag struts Applied loads
Shearwall Relative Rigidity: Designed capacity using flexible distribution
Design ShearwallForce /Length: Based on wall rigidity /length
Case 2 rigid diaphragm load distribution: 75% loads, torsional moment
IBC Occupancy ASCE 7 Equivalent
Category II All others Category II All others
Wind
ASCE 7 05 general analytic method for all bldgs
Seismic
ASCE 7 05 equivalent lateral force procedure
Design Wind Speed l0omph
Exposure Exposure D
Enclosure Enclosed
Structure Type Regular
Design Category D
Site Class D
Topographic Information [ft]
Shape Height Length
Site Location:
Spectral Response Acceleration
S1: 0.500g Ss:1.160g
Fundamental Period E -W N -S
T Used 0.095s 0.095s
Approximate Ta 0.095s 0.095s
Maximum T 0.114s 0.114 s
Response Factor 6.50 6.50
Fa: 1.04 Fv: 1.50
Company
Project
HODGE ENGINEERING
2615 JAHN AVE NW SUITE
GIG HARBOR, WA 98335
(253)- 857 -7055
E5
LATERAL ANALYSIS
ATION
WoodWorks® Shearwalls
WoodWorks® Shearwalls 8.21
Project Information
SOFTWARE FOR WOOD DESIGN
Sep. 18, 2012 13:27:49
6 of 34
WoodWorks® Shearwalls
LATERAL ANALYSIS Sep. 18, 2012 13:27:49
STORY INFORMATION
Structural Data
BLOCK and ROOF INFORMATION
7 of 34
Block
Dimensions [ft]
Floor /Ceiling
Depth [in]
Face
Type
Roof Panels
Slope
Overhang [ft]
Block 1
1 Story
E -W Ridge
Location X,Y
0.00
21.50
North
Side
30.0
1.00
Extent X,Y
53.50
31.50
South
Side
30.0
1.00
Ridge Y Location, Offset
37.00
0.00
East
Gable
90.0
1.00
Ridge Elevation, Height
20.00
9.00
West
Gable
90.0
1.00
Block 2
1 Story
N -S Ridge
Location X,Y
0.50
-0.50
North
Joined
150.0
1.00
Extent X,Y
20.50
22.00
South
Gable
90.0
1.00
Ridge X Location, Offset
10.50
0.00
East
side
30.0
1.00
Ridge Elevation, Height
16.50
6.00
West
side
30.0
1.00
Block 3
1 Story
N -S Ridge
Location X,Y
28.50
16.50
North
Joined
150.0
1.00
Extent X,Y
12.00
5.00
South
Gable
90.0
1.00
Ridge X Location, Offset
34.50
0.00
East
side
30.0
1.00
Ridge Elevation, Height
19.00
3.50
West
Side
30.0
1.00
WoodWorks® Shearwalls
LATERAL ANALYSIS Sep. 18, 2012 13:27:49
STORY INFORMATION
Structural Data
BLOCK and ROOF INFORMATION
7 of 34
Story
Elev [ft]
Floor /Ceiling
Depth [in]
Wall
Height [ft]
Ceiling
Level
Foundation
11.00
3.00
2.00
0.0
10.0
8.00
WoodWorks® Shearwalls
LATERAL ANALYSIS Sep. 18, 2012 13:27:49
STORY INFORMATION
Structural Data
BLOCK and ROOF INFORMATION
7 of 34
Wall
Sheathing [in]
Fasteners
Spcg [in]
Framing Members [in]
Apply
Grp Surf
Material
Thick
Orient
Size
Type
Edg
Fld
Blkg
Species
G
Spc
Notes
1 Ext
Struct Shthg
7/16
Vert
8d
Nail
6
12
yes
Hem -Fir
0.43
16
1,3
WoodWorks® Shearwalls
LATERAL ANALYSIS Sep. 18, 2012 13:27:49
Legend:
Grp Wall Design Group; Surf Exterior or interior surface of exterior wall; Spcg Edge or field nail spacing; Blkg Blocked; G Specific gravity;
Spc Wall stud spacing
Notes:
1. Capacity has been reduced according to IBC specific gravity adjustment.
3. Shear capacity for current design has been increased to the value for 15/32" sheathing with same nailing because stud spacing is 16" max. or
panel orientation is horizontal.
8 of 34
North -south
Shearlines
Type
Wall
Group(s)
Location
X [ft]
Extent [ft]
Start End
Length
[ft]
FHS [ft]
Wind Seismic
Height
[ft]
Line 1
Level 1
Line 1
Seg
1
0.00
0.00
52.50
52.50
47.25
47.25
8.00
Wall 1 -1
Seg
1
0.00
0.00
52.50
52.50
47.25
47.25
Opening 1
16.25
18.75
2.50
8.00
Opening 2
23.25
26.00
2.75
8.00
Line 2
Level 1
Line 2
NSW
14.00
49.00
52.50
3.50
0.00
0.00
8.00
Wall 2 -1
NSW
14.00
49.00
52.50
3.50
3.50
3.50
Line 3
Level 1
Line 3
Seg
1
20.00
0.00
49.00
49.00
23.25
23.25
8.00
Wall 3 -1
Seg
1
20.00
0.00
23.25
23.25
23.25
23.25
Line 4
Level 1
Line 4
NSW
28.00
17.00
52.50
35.50
0.00
0.00
8.00
Wall 4 -1
NSW
28.00
17.00
23.25
6.25
6.25
6.25
Wall 4 -2
NSW
29.50
49.00
52.50
3.50
3.50
3.50
Line 5
Level 1
Line 5
NSW
40.00
17.00
20.75
3.75
0.00
0.00
8.00
Wall 5 -1
NSW
40.00
17.00
20.75
3.75
3.75
3.75
Line 6
Level 1
Line 6
Seg
1
53.50
20.75
52.50
31.75
29.75
29.75
8.00
Wall 6 -1
Seg
1
53.50
20.75
52.50
31.75
29.75
29.75
Opening 1
34.50
36.50
2.00
8.00
East -west
Type
Wall
Location
Extent [ft]
Length
FHS [ft]
Height
Shearlines
Group(s)
Y [ft]
Start
End
[ft]
Wind Seismic
[ft]
Line A
Level 1
Line A
Seg
1
0.00
0.00
20.00
20.00
6.00
6.00
8.00
Wall A -1
Seg
1
0.00
0.00
20.00
20.00
6.00
6.00
Opening 1
3.00
17.00
14.00
8.00
Line B
Level 1
Line B
Seg
1
19.00
28.00
53.50
25.50
15.50
15.50
8.00
Wall B -1
Seg
1
17.00
28.00
40.00
12.00
7.00
7.00
Opening 1
31.25
36.25
5.00
8.00
Wall B -2
Seg
1
21.00
40.00
53.50
13.50
8.50
8.50
Opening 1
44.25
49.25
5.00
8.00
Line C
Level 1
Line C
Seg
1
22.00
0.00
20.00
20.00
12.00
12.00
8.00
Wall C -1
Seg
1
22.00
0.00
12.00
12.00
12.00
12.00
Wall C -2
NSW
23.50
20.00
28.00
8.00
8.00
8.00
Line D
Level 1
Line D
Seg
1
51.50
0.00
53.50
53.50
25.00
25.00
8.00
Wall D -2
Seg
1
49.00
14.00
29.25
15.25
7.50
7.50
Opening 1
17.50
25.25
7.75
8.00
Wall D -3
Seg
1
52.50
29.25
53.50
24.25
9.50
9.50
Opening 1
30.25
39.00
8.75
8.00
Opening 2
45.25
50.25
5.00
8.00
Wall D -1
Seg
1
52.50
0.00
14.00
14.00
8.00
8.00
Opening 1
4.00
10.00
6.00
8.00
WoodWorks® Shearwalls
LATERAL ANALYSIS Sep. 18, 2012 13:27:49
SHEARLINE, WALL and OPENING DIMENSIONS
Legend:
Type Seg segmented, prf perforated, NSW non- shearwall; Location dimension perp. to wall; FHS length of full height sheathing; Wall
Group(s) refer to Materials by Wall Group table, refer to Shear Results tables for each design case if more than one group
9 of 34
North -South
Shearlines
W
Gp
For
Dir
Ld. Case
Shear Force [plf]
V [Ibs] vmax
V /FHS
Int
Allowable Shear [plf]
Ext Co C Total
V [Ibs]
Crit.
Resp.
Line 1
Level 1
Lnl, Levl
1
S >N
1
3050 64.5
64.5
339 1.00 S 339
15995
0.19
1
N ->S
1
2758 58.4
58.4
339 1.00 S 339
15995
0.17
Line 3
Ln3, Levl
1
S ->N
1
7243 311.5
311.5
339 1.00 S 339
7871
0.92
1
N >S
1
6812 293.0
293.0
339 1.00 S 339
7871
0.87
Line 6
Ln6, Levl
1
S >N
1
4412 148.3
148.3
339 1.00 S 339
10071
0.44
1
N >S
1
4324 145.3
145.3
339 1.00 S 339
10071
0.43
East -West
W
For
Shear Force [plf]
Allowable Shear [pit]
Crit.
Shearlines
Gp
Dir
Ld. Case
V [Ibs] vmax
V /FHS
Int
Ext Co C Total
V [Ibs]
Resp.
Line A
Level 1
LnA, Levl
1
Both
1
1943 323.9
323.9
339 1.00 S 339
2031
0.96
Line B
LnB, Levl
1
Both
1
2626
169.4
339 1.00 S 339
5247
0.50
Wall B -1
1
Both
1
1186 169.4
169.4
339 1.00 339
2370
0.50
Wall B -2
1
Both
1
1440 169.4
169.4
339 1.00 339
2877
0.50
Line C
LnC, Levl
1
Both
1
3907
325.6
339 1.00 S 339
4062
0.96
Line D
LnD, Levi
1
Both
1
3316
132.6
339 1.00 S 339
8463
0.39
Wall D -2
1
Both
1
995 132.6
132.6
339 1.00 339
2539
0.39
Wall D -3
1
Both
1
1260 132.6
132.6
339 1.00 339
3216
0.39
Wall D -1
1
Both
1
1061 132.6
132.6
339 1.00 339
2708
0.39
WoodWorks® Shearwalls
LATERAL ANALYSIS Sep. 18, 2012 13:27:49
Flexible Diaphragm Wind Design
Legend:
W Grp Wall group as listed in Materials table; For Dir Direction of wind force along shearline; Ld. case Critical load case: ASCE 7 All heights
Case 1 or 2, ASCE 7 low rise T Transverse, L Longitudinal, all other results are for this load case; V Factored shear force applied to entire line
and amount taken by each wall; vmax Base shear V /FHS /Co Factored shear force per unit full height sheathing, divided by perforation factor Co
as per SDPWS eqn. 4.3 -6, and IBC eqn. 23 -4.
Following values marked with means that value for shearline is the one for wall with critical design response on line; V /FHS* Design shear force
factored shear force per unit full height sheathing, Int* Unit shear capacity of interior sheathing; Ext* Unit shear capacity of exterior sheathing
Co* Perforation factor; C Sheathing combination rule, A Add capacities, S Strongest side only, X Strongest side or twice weakest; Total*
Combined unit shear capacity inc. perforation factor; V Combined shear capacity of wall or total capacity of shearline Crit Resp* Critical
response Vapp /FHSNcap design shear force /unit shear capacity
Notes:
V /FHS shown is shear force for use in shearwall design. Vmax shown is V /FHS divided by perforation factor Co; it is the base shear to be used in
connection and collector design using IBC 2305.3.8.2.5 and SDPWS 4.3.6.4.1.1.
Refer to Elevation View diagrams for individual level for uplift anchorage force t for perforated walls given by IBC 2305.3.8.2.6,8 and SDPWS
4.3.6.4.2,4.
10 of 34
North -South
Shearlines
W
Gp
For
Dir
H/W Fact.
Int Ext
Shear Force [pit]
V [Ibs] vmax
V /FHS
Int
Allowable Shear [plf]
Ext Co C Total
V [lbs]
Crit.
Resp.
Line 1
Level 1
Lnl, Levl
1
Both
1.0 1.0
1477 31.3
31.3
242 1.00 S 242
11425
0.13
Line 3
Ln3, Levl
1
Both
1.0 1.0
2422 104.2
104.2
242 1.00 S 242
5622
0.43
Line 6
Ln6, Levl
1
Both
1.0 1.0
1461 49.1
49.1
242 1.00 S 242
7194
0.20
East -West
W
For
H/W Fact.
Shear Force [pH]
Allowable Shear [pit]
Crit.
Shearlines
Gp
Dir
Int Ext
V [lbs] vmax
V /FHS
Int
Ext Co C Total
V [lbs]
Resp.
Line A
Level 1
LnA, Levl
1
Both
1.0 .75
614 102.3
102.3
181 1.00 S 181
1088
0.56
Line B
LnB, Levl
1
Both
1.0 .81
739
47.7
196 1.00 S 196
3544
0.24
Wall B -1
1
Both
1.0 .81
334 47.7
47.7
196 1.00 196
1489
0.24
Wall B -2
1
Both
1.0 1.0
406 47.7
47.7
242 1.00 242
2055
0.20
Line C
LnC, Levl
1
Both
1.0 1.0
1958
163.2
242 1.00 S 242
2902
0.67
Line D
LnD, Levl
1
Both
1.0 .81
2049
81.9
196 1.00 S 196
5792
0.42
Wall D -2
1
Both
1.0 .87
615 81.9
81.9
196 1.00 212
1708
0.39
Wall D -3
1
Both
1.0 .81
778 81.9
81.9
196 1.00 196
2150
0.42
Wall D -1
1
Both
1.0 1.0
656 81.9
81.9
242 1.00 242
1934
0.34
WoodWorks® Shearwalls
LATERAL ANALYSIS Sep. 18, 2012 13:27:49
SEISMIC INFORMATION
Flexible Diaphragm Seismic Design
Notes:
Vertical Earthquake Load Ev 0.2 Sds D; Sds 0.80 Ev 0.160 D unfactored; 0.112 D factored; total dead load factor: 0.6 0.112 0.488
tension, 1.0 0.112 1.112 compression.
SHEAR RESULTS
Legend:
W Grp Wall group as listed in Materials table; For Dir force direction, always "both H/W factor Factor due to shearwall height -to -width ratio for
interior and exterior wall sheathing; V Factored shear force applied to entire line and amount taken by each wall; vmax Base shear V /FHS /Co
Factored shear force per unit full height sheathing, divided by perforation factor Co as per SDPWS eqn. 4.3 -6, and IBC eqn. 23 -4.
Following values marked with means that value for shearline is the one for wall with critical design response on line; V /FHS* Design shear force
factored shear force per unit full height sheathing, Int* Unit shear capacity of interior sheathing; Ext* Unit shear capacity of exterior sheathing
Co* Perforation factor; C Sheathing combination rule, A Add capacities, S Strongest side only, X Strongest side or twice weakest; Total*
Combined unit shear capacity inc. perforation factor and H/W factor; V Combined shear capacity of wall or total capacity of shearline Crit Resp*
Critical response Vapp /FHSNcap design shear force /unit shear capacity
Notes:
V /FHS shown is shear force for use in shearwall design. Vmax shown is V /FHS divided by perforation factor Co; it is the base shear to be used in
connection and collector design using IBC 2305.3.8.2.5 and SDPWS 4.3.6.4.1.1.
Refer to Elevation View diagrams for individual level for uplift anchorage force t for perforated walls given by IBC 2305.3.8.2.6,8 and SDPWS
4.3.6.4.2,4.
11 of 34
Building Area
Mass [lbs] [sq.ft]
Story Shear [lbs]
E -W N -S
Reliability Factor p
E -W N -S
Level1
Structure
62129 2086
62129
7658 7658
7658 7658
1.00 1.00
WoodWorks® Shearwalls
LATERAL ANALYSIS Sep. 18, 2012 13:27:49
SEISMIC INFORMATION
Flexible Diaphragm Seismic Design
Notes:
Vertical Earthquake Load Ev 0.2 Sds D; Sds 0.80 Ev 0.160 D unfactored; 0.112 D factored; total dead load factor: 0.6 0.112 0.488
tension, 1.0 0.112 1.112 compression.
SHEAR RESULTS
Legend:
W Grp Wall group as listed in Materials table; For Dir force direction, always "both H/W factor Factor due to shearwall height -to -width ratio for
interior and exterior wall sheathing; V Factored shear force applied to entire line and amount taken by each wall; vmax Base shear V /FHS /Co
Factored shear force per unit full height sheathing, divided by perforation factor Co as per SDPWS eqn. 4.3 -6, and IBC eqn. 23 -4.
Following values marked with means that value for shearline is the one for wall with critical design response on line; V /FHS* Design shear force
factored shear force per unit full height sheathing, Int* Unit shear capacity of interior sheathing; Ext* Unit shear capacity of exterior sheathing
Co* Perforation factor; C Sheathing combination rule, A Add capacities, S Strongest side only, X Strongest side or twice weakest; Total*
Combined unit shear capacity inc. perforation factor and H/W factor; V Combined shear capacity of wall or total capacity of shearline Crit Resp*
Critical response Vapp /FHSNcap design shear force /unit shear capacity
Notes:
V /FHS shown is shear force for use in shearwall design. Vmax shown is V /FHS divided by perforation factor Co; it is the base shear to be used in
connection and collector design using IBC 2305.3.8.2.5 and SDPWS 4.3.6.4.1.1.
Refer to Elevation View diagrams for individual level for uplift anchorage force t for perforated walls given by IBC 2305.3.8.2.6,8 and SDPWS
4.3.6.4.2,4.
11 of 34
0
engineering
e
inc,
COMPANY
Hodge Engineering
2615 Jahn Ave NW
Gig Harbor, WA 98335
(253)- 857 -7055
Sep. 6, 2012 17:36
PROJECT
THOMAS WINDAM HILL
R1
Design Check Calculation Sheet
Sizer 8.3
LOADS:
Load
Type
Distribution
Pat-
tern
Location [ft]
Start End
Magnitude
Start End
Unit
Loadl
Load2
Dead
Snow
Full Area
Full Area
15.00 (2.00)*
30.00 (2.00)*
psf
psf
*Tributary Width (ft)
MAXIMUM REACTIONS (Ibs) and BEARING LENGTHS (in)
1 0' 16
Unfactored:
Dead
Other
Factored:
Total
Bearing:
Load Comb
Length
Cb
315
480
315
480
795
795
#2
0.50*
1.00
0.50*
1.00
*Min. bearing length for beams is 1/2" for exterior supports
Lumber -soft, D.Fir -L, No.2, 4x12"
Self- weight of 9.35 plf included in loads;
Lateral support: top= full, bottom= at supports;
Analysis vs. Allowable Stress (psi) and Deflection n) using NDS 2005
Criterion
Analysis Value
Design Value
Analysis /Design
Shear
Bending(
Live Defl'n
Total Defl'n
fv 27
fb 517
0.13 <L/999
0.26 L/726
Fv' 207
Fb' 1138
0.53 L/360
0.80 L/240
fv /Fv' 0.13
fb /Fb' 0.45
0.25
0.33
DESIGN NOTES:
1. Please verify that the default deflection limits are appropriate for your application.
2. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1.
12 of 34
H odg e engineering Inc.
COMPANY
Hodge Engineering
Ave e (253)- 857 -7055
Sep. 6, 2012 17:38
PROJECT
THOMAS WINDAM HILL
Design Check Calculation Sheet
Sizer 8.3
LOADS:
Load
Type
Distribution
Pat-
tern
Location [ft]
Start End
Magnitude
Start End
Unit
Loadl
Load2
Dead
Snow
Full Area
Full Area
15.00(13.75)*
30.00(13.75)*
psf
psf
*Tributary Width (ft)
MAXIMUM RE/1rTInA1e /11.a+1 ...,.d DCACIAIr_` 1 CAI(_TIJQ l:..1
I0' 31
Unfactored:
Dead
Other
Factored:
Total
Bearing:
Load Comb
Length
Cb
318
619
318
619
937
937
#2
0.50*
1.00
#2
0.50*
1.00
*Min. bearing length for beams is 1/2" for exterior supports
Lumber -soft, D.Fir -L, No.2, 4x8"
Self- weight of 6.03 plf included in loads;
Lateral support: top= full, bottom= at supports;
Analysis vs. Allowable Stress (psi) and Deflection (n) using NDS 2005
Criterion
Analysis Value
Design Value
Analysis /Design
Shear
Bending(
Live Defl'n
Total Defl'n
fv 33
fb 275
0.00 <L/999
0.01 <L/999
Fv' 207
Fb' 1345
0.10 L/360
0.15 L/240
fv /Fv' 0.16
fb /Fb' 0.20
0.04
0.05
DESIGN NOTES:
1. Please verify that the default deflection limits are appropriate for your application.
2. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1.
13 of 34
odl e
engineering inc.
COMPANY
Hodge Engineering
2615 Jahn Ave NW
Gig Harbor, WA 98335
253)- 857 -7055
Sep. 6, 2012 17:42
PROJECT
THOMAS WINDAM HILL
R3
Design Check Calculation Sheet
Sizer 8.3
LOADS:
Load
Type
Distribution
Pat-
tern
Location [ft]
Start End
Magnitude
Start End
Unit
Loadl
Load2
Dead
Snow
Full Area
Full Area
15.00 (3.50)*
30.00 (3.50)*
psf
psf
*Tributary Width (ft)
MAXIMUM REACTIONS (Ibs) and BEARING LENGTHS (in)
10. 5
Unfactored:
Dead
Other
Factored:
Total
Bearing:
Load Comb
Length
Cb
146
263
146
263
409
409
#2
0.50*
1.00
#2
0.50*
1.00
*Min. bearing length for beams is 1/2" for exterior supports
Lumber -soft, D.Fir -L, No.2, 4x8"
Self- weight of 6.03 plf included in loads;
Lateral support: top= full, bottom= at supports;
Analysis vs. Allowable Stress (psi) and Deflection n) using NDS 2005
Criterion
Analysis Value
Design Value
Analysis /Design
Shear
Bending(
Live Defl'n
Total Defl'n
fv 18
fb 200
0.01 <L/999
0.02 <L/999
Fv' 207
Fb' 1345
0.17 L/360
0.25 L/240
fv /Fv' 0.09
fb /Fb' 0.15
0.05
0.06
DESIGN NOTES:
1. Please verify that the default deflection limits are appropriate for your application.
2. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1.
14 of 34
engineering inc.
COMPANY
Hodge Engineering
2615 Jahn Ave 98
Gig Harbor, 98335
(253)- 857 -7055
Sep. 6, 2012 17:44
PROJECT
THOMAS WINDAM HILL
R4
Design Check Calculation Sheet
Sizer 8.3
LOADS:
Load
Type
Distribution
Pat-
tern
Location [ft]
Start End
Magnitude
Start End
Unit
Loadl
Load2
Dead
Snow
Full Area
Full Area
15.00 (3.50)*
30.00 (3.50)*
psf
psf
*Tributary Width (ft)
MAXIMUM REACTIONS (Ibs) and BEARING LENGTHS (in)
1
I0 81
Unfactored:
Dead
Other
Factored:
Total
Bearing:
Load Comb
Length
Cb
234
420
234
420
654
654
#2
0.50*
1.00
#2
0.50*
1.00
*Min. bearing length for beams is 1/2" for exterior supports
Lumber -soft, D.Fir -L, No.2, 4x8"
Self- weight of 6.03 plf included in loads;
Lateral support: top= full, bottom= at supports;
Analysis vs. Allowable Stress (psi) and Deflection n) using NDS 2005
Criterion
Analysis Value
Design Value
Analysis /Design
Shear
Bending(
Live Defl'n
Total Defl'n
fv 33
fb 512
0.05 <L/999
0.10 L/960
Fv' 207
Fb' 1345
0.27 L/360
0.40 L/240
fv /Fv' 0.16
fb /Fb' 0.38
0.20
0.25
DESIGN NOTES:
1. Please verify that the default deflection limits are appropriate for your application.
2. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1.
15 of 34
d> H odig e engineeringinc.
COMPANY
Hodge Engineering
2615 Jahn Ave NW
(253)-857-7055
Sep. 6, 2012 17:45
PROJECT
THOMAS WINDAM HILL
R5
Design Check Calculation Sheet
Sizer 8.3
LOADS:
Load
Type
Distribution
Pat-
tern
Location [ft]
Start End
Magnitude
Start End
Unit
Loadl
Load2
Dead
Snow
Full Area
Full Area
15.00(17.00)*
30.00(17.00)*
psf
psf
*Tributary Width (ft)
MAXIMUM REACTIONS Ibs and BEARING LENGTHS (in)
o
0 51
Unfactored:
Dead
Other
Factored:
Total
Bearing:
Load Comb
Length
Cb
653
1275
653
1275
1928
1928
#2
0.88
1.00
#2
0.88
1.00
Lumber -soft, D.Fir -L, No.2, 4x8"
Self- weight of 6.03 plf included in loads;
Lateral support: top= full, bottom= at supports;
Analysis vs. Allowable Stress (psi) and Deflection n) using NDS 2005
Criterion
Analysis Value
fv 86
fb 943
0.04 <L/999
0.07 L/841
Design Value
Fv' 207
Fb' 1345
0.17 L/360
0.25 L/240
Analysis /Design
fv /Fv' 0.42
fb /Fb' 0.70
0.24
0.29
Shear
Bending(
Live Defl'n
Total Defl'n
DESIGN NOTES:
1. Please verify that the default deflection limits are appropriate for your application.
2. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1.
16 of 34
H odge
engineering Inc.
COMPANY
Hodge Engineering
Gig Harbor, WA 98335
Gig 98
(253)- 857 -7055
Sep. 6, 2012 17:49
PROJECT
THOMAS WINDAM HILL
R6
Design Check Calculation Sheet
Sizer 8.3
LOADS:
Load
Type
Distribution
Pat-
tern
Location [ft]
Start End
Magnitude
Start End
Unit
Loadl
Load2
Dead
Snow
Full Area
Full Area
15.00 (2.00)*
30.00 (2.00)*
psf
psf
*Tributary Width (ft)
MAXIMUM RE)
10' 21
Unfactored:
Dead
Other
Factored:
Total
Bearing:
Load Comb
Length
Cb
36
60
36
60
96
96
#2
0.50*
1.00
#2
0.50*
1.00
*Min. bearing length for beams is 1/2" for exterior supports
Lumber -soft, D.Fir -L, No.2, 4x8"
Self- weight of 6.03 plf included in loads;
Lateral support: top= full, bottom= at supports;
Analysis vs. Allowable Stress (psi) and Deflection n) using NDS 2005
Criterion
Analysis Value
Design Value
Analysis /Design
Shear
Bending(
Live Defl'n
Total Defl'n
fv 2
fb 19
0.00 <L/999
0.00 <L/999
Fv' 207
Fb' 1345
0.07 L/360
0.10 L/240
fv /Fv' 0.01
fb /Fb' 0.01
0.00
0.00
DESIGN NOTES:
1. Please verify that the default deflection limits are appropriate for your application.
2. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1.
17 of 34
H odg e
engineering nc.
COMPANY
Hodge Engineering
2 6198
Gig Harbor, WA 98335
(253)- 857 -7055
Sep. 6, 2012 17:54
PROJECT
THOMAS WINDAM HILL
R7
Design Check Calculation Sheet
Sizer 8.3
LOADS:
Load
Type
Distribution
Pat-
tern
Location [ft]
Start End
Magnitude
Start End
Unit
Loadl
Load2
Dead
Snow
Full Area
Full Area
15.00 (3.00)*
30.00 (3.00)*
psf
psf
*Tributary Width (ft)
MAXIMUM REACTIONS (lbs) and BEARING LENGTHS (in)
A' 5A 101
Unfactored:
Dead
Other
Factored:
Total
Bearing:
Load Comb
Length
Cb
128
225
128
225
353
353
#2
0.50*
1.00
0.50*
1.00
*Min. bearing length for beams is 1/2" for exterior supports
Lumber -soft, D.Fir -L, No.2, 4x8"
Self- weight of 6.03 plf included in loads;
Lateral support: top= full, bottom= at supports;
Analysis vs. Allowable Stress (psi) and Deflection (in) using NDS 2005
Criterion
Analysis Value
fv 16
fb 172
0.01 <L/999
0.01 <L/999
Design Value
Fv' 207
Fb' 1345
0.17 L/360
0.25 L/240
Analysis /Design
fv /Fv' 0.08
fb /Fb' 0.13
0.04
.0.05
Shear
Bending(
Live Defl'n
Total Defl'n
DESIGN NOTES:
1. Please verify that the default deflection limits are appropriate for your application.
2. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1.
18 of 34
,6
H Odg e engineering inc.
COMPANY
Hodge Engineering
(253)- 857 -7055
Sep. 6, 2012 17:52
PROJECT
THOMAS WINDAM HILL
Design Check Calculation Sheet
Sizer 8.3
LOADS:
Load
Type
Distribution
Pat-
tern
Location [ft]
Start End
Magnitude
Start End
Unit
Loadl
Load2
Dead
Snow
Full Area
Full Area
15.00(20.00)*
30.00(20.00)*
psf
psf
*Tributary Width (ft)
MAXIMUM REACTIONS (Ibs) and BEARING LENGTHS (in)
I p' 81
Unfactored:
Dead
Other
Factored:
Total
Bearing:
Load Comb
Length
Cb
1260
2400
1260
2400
3660
3660
#2
1.06
1.00
#2
1.06
1.00
Timber -soft, D.Fir -L, No.2, 6x12"
Self- weight of 15.02 plf included in loads;
Lateral support: top= full, bottom= at supports;
Analysis vs. Allowable Stress (psi) and Deflection n) using NDS 2005
Criterion
Analysis Value
Design Value
Analysis /Design
Shear
Bending(
Live Defl'n
Total Defl'n
fv 66
fb 725
0.06 <L/999
0.11 L/880
Fv' 195
Fb' 1006
0.27 L/360
0.40 L/240
fv /Fv' 0.34
fb /Fb' 0.72
0.23
0.27
DESIGN NOTES:
1. Please verify that the default deflection limits are appropriate for your application.
2. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1.
19 of 34
H odg e
engineering inc.
COMPANY
Hodge Engineering
G 9Gr 9335
Sep. 6, 2012 17:57
PROJECT
THOMAS WINDAM HILL
Design Check Calculation Sheet
Sizer 8.3
LOADS:
Load
Type
Distribution
Pat-
tern
Location [ft]
Start End
Magnitude
Start End
Unit
Loadl
Load2
Dead
Snow
Full Area
Full Area
15.00 (3.50)*
30.00 (3.50)*
psf
psf
*Tributary Width (ft)
MAXIMUM REACTIONS (Ibs) and BEARING LENGTHS (in)
IO'
15
Unfactored:
Dead
Other
Factored:
Total
Bearing:
Load Comb
Length
Cb
464
788
464
788
1251
1251
#2
0.57
1.00
#2
0.57
1.00
Lumber -soft, D.Fir -L, No.2, 4x12"
Self- weight of 9.35 plf included in loads;
Lateral support: top= full, bottom= at supports;
Analysis vs. Allowable Stress (psi) and Deflection n) using NDS 2005
Criterion
Analysis Value
fv 42
fb 763
0.18 <L/999
0.34 L /530
Design Value
Fv' 207
Fb' 1138
0.50 L/360
0.75 L/240
Analysis /Design
fv /Fv' 0.20
fb /Fb' 0.67
0.36
0.45
Shear
Bending(
Live Defl'n
Total Defl'n
DESIGN NOTES:
1. Please verify that the default deflection limits are appropriate for your application.
2. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1.
20 of 34
H odg e
engineering nc.
COMPANY
Hodge Engineering
G Harbor, WA 98335
(253)- 857 -7055
Sep. 6, 2012 17:56
PROJECT
THOMAS WINDAM HILL
Design Check Calculation Sheet
Sizer 8.3
LOADS:
Load
Type
Distribution
Pat-
tern
Location [ft]
Start End
Magnitude
Start End
Unit
Loadl
Load2
Dead
Snow
Full Area
Full Area
15.00(16.50)*
30.00(16.50)*
psf
psf
*Tributary Width (ft)
MAXIMUM REACTIONS (Ibs) and BEARING LENGTHS (in)
10' 61
Unfactored:
Dead
Other
Factored:
Total
Bearing:
Load Comb
Length
Cb
766
1485
766
1485
2251
2251
#2
1.03
1.00
#2
1.03
1.00
Lumber -soft, D.Fir -L, No.2, 4x10"
Self- weight of 7.69 plf included in loads;
Lateral support: top= full, bottom= at supports;
Analysis vs. Allowable Stress (psi) and Deflection n) using NDS 2005
Criterion
Analysis Value
Design Value
Analysis /Design
Shear
Bending(
Live Defl'n
Total Defl'n
fv 77
fb 812
0.04 <L/999
0.07 <L/999
Fv' 207
Fb' 1242
0.20 L/360
0.30 L/240
fv /Fv' 0.37
fb /Fb' 0.65
0.20
0.23
DESIGN NOTES:
1. Please verify that the default deflection limits are appropriate for your application.
2. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1.
21 of 34
H odg e
engineering inc.
COMPANY
Hodge Engineering
2698
Gig Harbor, WA 98335
(253)- 857 -7055
Sep. 6, 2012 17:59
PROJECT
THOMAS WINDAM HILL
R11
Design Check Calculation Sheet
Sizer 8.3
LOADS:
Load
Type
Distribution
Pat-
tern
Location (ft)
Start End
Magnitude
Start End
Unit
Loadl
Load2
Dead
Snow.
Full Area
Full Area
15.00 (2.00)*
30.00 (2.00)*
psf
psf
*Tributary Width (ft)
,4 QCnoIAI(_` 1 CAIP!TUC
MAXIMUM RE
1 34
Unfactored:
Dead
Other
Factored:
Total
Bearing:
Load Comb
Length
Cb
54
90
54
90
144
144
#2
0.50*
1.00
#2
0.50*
1.00
*Min. bearing length for beams is 1/2" for exterior supports
Lumber -soft, D.Fir -L, No.2, 4x8"
Self- weight of 6.03 plf included in loads;
Lateral support: top= full, bottom= at supports;
Analysis vs. Allowable Stress (psi) and Deflection n) using NDS 2005
Criterion
Analysis Value
Design Value
Analysis /Design
Shear
Bending(
Live Defl'n
Total Defl'n
fv 5
fb 42
0.00 <L/999
0.00 <L/999
Fv' 207
Fb' 1345
0.10 L/360
0.15 L/240
fv /Fv' 0.02
fb /Fb' 0.03
0.01
0.01
DESIGN NOTES:
1. Please verify that the default deflection limits are appropriate for your application.
2. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1.
22 of 34
H
engineering inc.
COMPANY
Hodge Engineering
335
(253) 857 -7055
Sep. 6, 2012 18:00
PROJECT
THOMAS WINDAM HILL
Design Check Calculation Sheet
Sizer 8.3
LOADS:
Load
Type
Distribution
Pat-
tern
Location [ft]
Start End
Magnitude
Start End
Unit
Loadl
Load2
Dead
Snow
Full Area
Full Area
15.00(11.50)*
30.00(11.50)*
psf
psf
*Tributary Width (ft)
MAXIMUM REI
'TI %MC III. ......1 QCACIAIf_ 1 CAM(`TUC f:..\
1 3
Unfactored:
Dead
Other
Factored:
Total
Bearing:
Load Comb
Length
Cb
268
517
268
517
785
785
#2
0.50*
1.00
#2
0.50*
1.00
*Min. bearing length for beams is 1/2" for exterior supports
Lumber -soft, D.Fir -L, No.2, 4x8"
Self- weight of 6.03 plf included in Toads;
Lateral support: top= full, bottom= at supports;
Analysis vs. Allowable Stress (psi) and Deflection n) using NDS 2005
Criterion
Analysis Value
Design Value
Analysis /Design
Shear
Bending(
Live Defl'n
Total Defl'n
fv 28
fb 231
0.00 <L/999
0.01 <L/999
Fv' 207
Fb' 1345
0.10 L/360
0.15 L/240
fv /Fv' 0.13
fb /Fb' 0.17
0.04
0.04
DESIGN NOTES:
1. Please verify that the default deflection limits are appropriate for your application.
2. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1.
23 of 34
H cod a e
engineering inc.
COMPANY
Hodge Engineering
2615 Jahn Ave NW
Gig Harbor, WA 98335
(253)-857-7055
Sep. 6, 2012 18:01
PROJECT
THOMAS WINDAM HILL
R13
Design Check Calculation Sheet
Sizer 8.3
LOADS:
Load
Type
Distribution
Pat-
tern
Location [ft]
Start End
Magnitude
Start End
Unit
Loadl
Load2
Dead
Snow
Full Area
Full Area
15.00(13.00)*
30.00(13.00)*
psf
psf
*Tributary Width (ft)
uh..V ■4 QCADIAIt• I CAIr-rue i:.,a
MAXIMUM REP•TrnMrc
1 0 31 R
Unfactored:
Dead
Other
Factored:
Total
Bearing:
Load Comb
Length
Cb
302
585
302
585
887
887
#2
0.50*
1.00
#2
0.50*
1.00
*Min. bearing length for beams is 1/2" for exterior supports
Lumber -soft, D.Fir -L, No.2, 4x8"
Self- weight of 6.03 plf included in loads;
Lateral support: top= full, bottom= at supports;
Analysis vs. Allowable Stress (psi) and Deflection n) using NDS 2005
Criterion
Analysis Value
Design Value
Analysis /Design
Shear
Bending(
Live Defl'n
Total Defl'n
fv 31
fb 260
0.00 <L/999
0.01 <L/999
Fv' 207
Fb' 1345
0.10 L/360
0.15 L/240
fv /Fv' 0.15
fb /Fb' 0.19
0.04
0.05
DESIGN NOTES:
1. Please verify that the default deflection limits are appropriate for your application.
2. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1.
24 of 34
Ramie
Lumber
Perp to
rain;
P ,L (Ibs)
3280
.Compression Capacity Parallel to Grain, Pe(tbs) (100).
Compression Capacity Parallel to Grain P c (Ibs) (160),
Size
2x4
Grade
a2
IVirainaI Top to Heightl1t)
Nc ritinal Top Plate Hei j h1(1t)
8
3170
5285
2680
4305
1 l
2120
0
3535
1765
12
1490
2485
8
X3345
557
9
2680
4470
10
2180
3 635
11
1 '5
3010
12
1520
2530
4.1nch
Wall
3x4
42
t
5470
2945
2 2x4
12
1
6565
6340
5165
4240
3535
2985
6685 1
5365
4360
3610
3040
4x4
12
i.
7655
73 95
6025
4945
4126
3480
1800
6260
5090
4215
3545
3 2x4
62
1
9845
9510
7745
6360
5300
4475
10030
8045
6545
5420
4555
4x6
12
12030
11540
942
7745
6460
5460
122:15.
9810
7980
6610
5560
4x8
12
15860
15090
12345
10165
8485
7175
16035 .1
12890
10500
8700
7320
4x10
1 12
t
20235
19080
15650
12910
10790
9130
20365 1
16395
13360
11080
9325
6-Inc llr
2x6
12
5155'
97 s
7975
6 5
050
X60
110030
18385
9280
15465
7780'
12965
6570
10950
5600
9335
3x6
92
8595
14945
13290
11610
19085
8765
2.2x6
e2
10315
47935;,;
1x 0
13935
42106
x'10505
220611
25735
18560
21554
,15560
18155
13140
15334
11240
13 070
4x6
'02
P
12030
20Y925
181305
1!8255
14120
12270
3.2x6.
12
1
15470
26905
239
20900
18155
15775
33090
27840
23340
19 15
16840 <a;
°19535
26640
6x6
11
18905
.-252i6p
34450
23 80
32125
��21565'
,29410
1 9480
26560
17435
3 4
46715
30165
41130
6140
35650
22675
30785
6x8
X3`1
1
25780
23775
Post Capacities
See footnotes
Post Allowable Compression Load Tables:
strongtie .com /post_capacities.asp
Post Capacities
Post Allowable Compression Loads for Douglas Fir Larch
Post Allowable Compression Loads for Southern Pine
roll over images below
to see larger image
HD3B Vertical HTT4 Vertical
Installation Installation
Typical CbSQ- HDU Vertical
SDS2 lnstallation Installation
www.strongtie.com
Post Compression Loads
for Douglas Fir Larch
for Southern Pine
for Spruce Pine Fir
for Hem Fir
Post Tension Loads
for Douglas Fir Larch
for Southern Pine
for Spruce Pine Fir
for Hem Fir
Catalog pages (PDF)
Help for dow nloads
25 of 34
SIMPSON
Framing
Lumber
Compression .Capacity Parallel to Grain, Pc (ins); (100)
Perp lo
Grain,
(Ibs)
Compression Capacity ParaIetto Grain, P (ibs) (100),
Compression Capacity Parallel to Grain, P (Ibs) (160)
Sire
Grade
i .P
Nominal Top Plate Height (ft)
No mina Top Plate Height 01
8
9
10
1 1
12
8
9
10
11
12
4 -1nch
Will
2x4
1 2
1 2125
2630
2115
3525
1730
1435
2395
1210
2020
2745 tr
2180.
1770
1465
2440
1230
2050
3x4
12
1
3545
4385;
2880
4 70
36341
2950
2.2x4
12
4255
5260
4230
3460
3475
2425
5485
60400 a'=
".8230
4200
435$
3540
2925
2460
2870
44
12
4960
8140
4935
4035
3355
2830
"5085"
6535:
4125
5305
3415
4390
3-2x4
12395
g
6380
X890'
6340
5185
4310
3635
369
4 -20
12
6 -1nch
1It
8605
10625-
7950
313250
15900,
18559
23855:
8455
6880
11470
13765
16055
20615.
6915
5905
9840
X11810 y
13780
17715
5759
4850
114970
9385 1'.
8715
7735
7075
5855 4920
8996 7635
110790 9165
125911 10690s
16185... 6374
6-Inch
Inch
2x6
3340
5065
0 4365
3x6
12
1
5570
8 40
101
11820
15195
7270
8725
10180_
t <13090,
18785
21895
28150
4
128
.154fiG
18045
2 3 2 0 5
10710
12854
14995
2'2x6
#2.
�1._
.6685:
3.2x62
7745
4 -2i6
°12
1:..
10025.
1 75,
Fran in9
Lumber I pap to
Compression .Capacity Parallel to Grain, Pc (ins); (100)
Compression Capacity Parallel to Grain, Pc (Ibs) (160)
Size
2x4
Grade .p o 0s1
Grade
No ina
Top to Height (ft)
Nerniael•Top Plate Height Ht)
8
10
11
12
8 9 10' 11
9
4-lnch
Wall
12 1 2965
3200`
2580
2115
1765
1490
3360 2675
2175
1800
1515
3x4
12 5955
5330.
4305
3530
2940
2480
5600 '1 4455
6720" 5345
3620
4345
3000
3600
2520
31)25
2 -2x4
12 1 5935
6400
5165
4235
3525
2975
4x4
12 1 6920
7465 ;,1
6025
4640
4115
3475
7840 6240
5070
6520
4200
3530
4540
3-2x4
11/12 5205
4x6
12 1 10875
11680
9435
7745
10 85
6455
6455
5450
5
.52290 12875
960
6590
8680
0
5545
7300
4x8
12 14335
1 8
12395
4x10
/2 1 18290
19445
15760
12960
10810 9140
20560 1 16395
13350
11060
9310
6 -1nch
1It
2x6
.12 46601
9345
f 819
13650.
3095,. u
11830
613 Q� 5305
10215 8840'
112 9375
18800 15620
22564 18746
21$74
33 28120
30025 26824
40940 3657,5.
7825
°,13045'
;15655.
°18280'
.23480
23595
.�32l 0
_a •6595
10990
.13185
15385
19780
20510
2 106,
5610
3x6
2.2x&
4a6
12 7770
02 9325
a2 10875
15570
'9350
18685
,16380
14195
6550"
122'80 106tH
14300 12375 .26325..,
1 1220
13090:'
1600s
19 10
3 =2x6'
#2 -13985
28030
495
X29315
24570"
2027
27640
21290
r;18835r'�4
25680
18385 15910;'
17 0 .15655
23540 21345
16830.
17975°
245115.
6x6..
6x5
11 �t_ 17090
1 23305
Framing
Lumber` 1
°Pero to
Grain,
Pc.l.(Ibs)
C(impression CapacityPara lie l to Grain, P (tbs) (100)
.Compression Capaolty,Parattol to Grain, P (lb sy (160)
Size
Grade
Nomina Tap Plate Height (ft)
Nomina Top Plato Height (It)
8
10
11
°'12
6
9
4 -1nch
Wall
2x4
11/12 2230
2775.
22 0
1850
n 1540
1305,-
2930
w. ,2340
1905
..1575
1325..
3x4
11/12 1 3720
4025
3745
3080
2570
2170
,,4SB5
58x'
3175
2630
2210
2.2x4
01/02 4465
5545
.44 195
3695
3085
3595
2605
3040
5865
#0
4675
5455
7015
3805
4440
5710
3155
3680
4730
2655
3095
3980
4x4
11/12 5205
.6470:
52 4
4310
3 -2x4
#1/12 I 6695
8320'
°6745,'
5545
4625
3910
8795"
11 30
4.2x4
1/12
01/42
1 8925
Hogs
l45
12905
15485
8990.
7395
'6035
10060
"12070.
6165
.`.'5265=
87!60
..10515:.
5215
457
7625
9150
7615
.1..;16770 N,°
111280
6310
5725:,
954 5.E
11450
5310
0
9770
6 •I rch
loch
2x6.
f 3505
.6685
11475
13770
160
.19200
80;5
43425
16110
3x6
#1/ #2 1 5845
2.2x6
#.1/12 7015
13540
3 -2x 1'
4.2x6.
11
8180
18065
23;230'
16070
2 •660
.14 85
518110
1 65
15770
10675
13730'
22395
28795
24
2030
13360_
17180
11400
`14660,
11/12-
i s 10520
Pnct Canaritiac
See footnotes
Post Allowable Compression Loads for Spruce Pine Fir
See footnotes
Post Allowable Compression Loads for Hem Fir
See footnotes
Post Tension Load Tables:
Post Tension Loads for Douglas Fir Larch
strongtie .com /post_capacities.asp
top
26 of 34
Framing
Lumber
Aliow able Tension
Pt, (Ibs) (160)
Size
Grade
Bolt Diameter (in)
1
4 -Inch
Wall
2x4
#2
7245
6080
5820
5305
5045
3x4
#2
12075
10135
9705
8840
8410
2 -2x4
#2
14490
12160
11645
10610
10090
4x4
#2
16905
14190
13585
12375
11775
3 -2x4
#2
21735
18240
17465
15915
15135
4x6
#2
23025
19325
18500
16855
16035
4x8
#2
28015
23510
22510
20510
19510
4x10
#2
32765
27500
26330
23990
22815
6-Inch
Wall
2x6
#2
9865 m
8860
8635
8185
7960
3x6
#2
16445
14765
14390
13640
13270
2 -2x6
#2
19735.
17715
17265
16370
15920
4x6
#2
23025
20670
20145
19100
18575
3-2x6
#2
29600'
26575
25900
24555
23885
6x6
#1
39930
35845
34940
33125
32215
6x8
#1
54450
48880
47645
45170
43930
Framing
Lumber
Allowable Tension
Pt, (Ibs) (160)
Size
Grade
Bolt Diameter( in)
1
4 -Inch
Wall
2x4
#2
7245
6080
5820
5305
5045
3x4
#2
12075
10135
9705
8840
8410
2 -2x4
#2
14490
12160
11645
10610
10090
4x4
#2
16905
14190
13585
12375
11775
3 -2x4
#2
21735
18240
17465
15915
15135
4x6
#2
23025
19325
18500
16855
16035
4x8
#2
28015
23510
22510
20510
19510
4x10
#2
32765
27500
26330
23990
22815
6-Inch
Wall
2x6
#2
9865
8860
8635
8185
.7960
3x6
#2
16445
14765
14390
13640
13270
2 -2x6
#2
19735
17715
17265
16370
15920
4x6
#2
23025.
20670
20145
19100
18575
3 -2x6
#2
29600
'26575
25900
24555
23885
6x6
#1
39930.
35845
34940
33125.
32215
6x8
#1
54450
48880
47645
45170
43930
See footnotes
Post Tension Loads for Southern Pine
See footnotes
Post Tension Loads for Spruce Pine Fir
strongtie .com /post_capacities.asp
27 of 34
Framing
Lumber
Allowable Tension
Pt, Ibs. (160)
Size
Grade
Bolt Diameter
6
'✓2
Size
Grade
1.13
(in)
0
',z
Vs
7,4
1_
4845
2x4
#1/ #2
5670
4760
4555
4150
3950
7680
3x4
#1/ #2
9450
7930
7595
6920
6580
4 -Inch
2 -2x4
#1/ #2
11340
9520
9115
8305
7900
Wall
4x4
#1/ #2
13230
11105
10630
9685
9215
26460
3 -2x4
#1/ #2
17010
14275
13670
12455
11845
9010
4 -2x4
#1/#2
22680
19035
18225
16605
15795
13480
2x6
#1/ #2
7720
6930
6755:
6405
6230
15765
3x6
#1/ #2
12870
11555
11260
10675
10385
6 -Inch
Wall
2 -2x6
#1/ #2
15445
13865
13515
12810
12460
3 -2x6
#1/ #2
18020
16175
15765
14945
14535
4-2x6
#1/ #2
23165
20795
20270
19215
18690
Framing
Lumber
"AHo cable Tension
Pt, lbs. (160)
Size
Grade
Bolt Diameter (in).
6
'✓2
7/8
1.13
4 -Inch
Wall
2x4
#2
6615
5550
5315
4845
4605
3x4
#2
11025
9255
8860
8070
7680
2 2x4
#2
13230
11105
10630
9685
9215
4x4
#2
15435
12955
12405
11300
10750
3 -2x4
#2
19845
16655
15945
14530
13820
4 -2x4
#2
26460
22210
21265
19375
18430
6 -Inch
Wall
2x6
#2
9010
8090
7885
7475
7270
3x6
#2
15015
13480
13140
12455
.12115
2 -2x6
#2
18020
16175
15765
14945
14535
3-2x6
#2
21020
18870
18395"
17440'
16960
21805:
4 -2x6.
#2,:.
27025
24265
23650
,22420
lb (in)
1.5
.2.5.
3
3.5
4.5
5.5
6
Cb
1,25
1.15
1.13
1.11
1.08
1.07
1
See footnotes
Post Tension Loads for Hem Fir
1. Allow able (ASD) loads are based on the 2005 National Design Specification for Wood Construction (NDS) for lumber w ith a moisture content of
19% or less.
2. Compression parallel to grain loads are based on an effective post height, le, equal to the nominal height plus 1 1/8" (due to the most common pre
cut stud lengths) minus 4 1/2" (thickness of 3 2x plates). Ud ratio is based on d 3 1/2" for 4 -inch w all
and d 5 1/2" for 6 -inch w all.
3. Shaded values are limited by the Fbrpendicular to Grain bearing allow able load, P L, w hen posts bear on wood sill plates. Where posts and sill
plates are different species, Designer shall limit allow able load to the lower of the post capacity or the perpendicular to grain capacity for each
species used.
4. Perpendicular to grain allow able loads do not include the NDS Bearing Area Factor, Cb. For posts w hose bearing area is not closer than 3" from the
end of a sill plate, the PC values may be multiplied by Cb.
strongtie .com /post_capacities.asp
lb Bearing Length (post thickness)
Cb Bearing Area Factor per NDS 3.10.4
28 of 34
5/3/2011 Post Capacities
5. Allow able tension loads are based on net section assuming hole size equal to bolt diameter plus 1/16" with the hole drilled on the 3 1/2" face of post
for a 4 -inch w all and on the 5 1/2" face of post for a 6 -inch w all. Tension loads have been increased for w ind or seismic loading w ith no further
increase allowed. Reduce w here other loads govern.
6. Values do not consider combined axial and out -of -plane bending.
Printed May 3, 2011 fromhttp /www.strongtie.com/products /connectors post_capacities.asp 2011 Simpson Strong-Tee
strongtie .com /post_capacities.asp
29 of 34
.i top
Lic. KW- 06007122
Licensee :>'HODGE ENGINEERING INC
ENERCALC, INC. 1983 Build:6.12.3.14, Ver :6.12.3.14
Description Point load on continuous foundation
Material Properties
fc
fr= fc /2 7.50
kJ Density
X, LtWt Factor
Elastic Modulus
fy Main Rebar
E Main Rebar
Overall MAXimum
D Only
L Only
S Only
L +S
D+L
D +S
D+L +S
Hodge Engineering, Inc.
2615 Jahn Ave NW
Suite IIIW E5
Gig Harbor, WA
Gngin o c- :nC inc._ 253 -857 -7055
Ho
2.50 ksi
375.0 psi
145.0 pcf
1.0
3,122.0 ksi
Fy Stirrups
40.0 ksi E Stirrups
29,000.0 ksi Stirrup Bar Size
Number of Resisting Legs Per Stirrup
Load Combination 2006 IBC ASCE 7 -05
t Cross Section 8� Reinforcing Details
r Applied Loads
Beam self weight calculated and added to loads
Load for Span Number 1
Uniform Load D 0.50, S 1.0 k/ft, Tributary Width 1.0 ft
Point Load L 7.0 k a 2.50 ft
DESIGN SUMMARY
Maximum Bending Stress Ratio 0.842: 1
Section used for this span Typical Section
Mu Applied 17.981 k -ft
Mn Phi Allowable
Load Combination
Location of maximum on span
Span where maximum occurs
Vertical Reactions Unfactored
Load Combination Support 1
21.351 k -ft
+1 .20 D +1.60 L+0.50 S +1.60 H
2,500ft
Span 1
7.613
1.613
3.500
2.500
6.000
5.113
4.113
7.613
d) Phi Values Flexure
Shear:
R1
Support 2
7.612
1.612
3.500
2.500
6.000
5.112
4.112
7.612
0.90
0.750
0.850
40.0 ksi
29,000.0 ksi
3
2
L(7)
Span =5.0 ft
Title
Engineer:
Project Desc.:
Inverted Tee Section, Stem Width 6.0 in, Total Height 18.0 in, Top Flange Width 12.0 in,
Span #1 Reinforcing....
244 at 3.0 in from Bottom, from 0.0 to 5.0 ft in this span
144 at 3.0 in from Top, from 0.0 to 5.0 ft in this span
i Shear Stirrup Requirements 1
Between 0.00 to 0.68 ft, PhiVc Vu, Req'd Vs 0.009011, use stirrups spaced at 7.000 in
Between 0.69 to 4.31 ft, PhiVc/2 Vu PhiVc, Req'd Vs Not Reqd 11.5.6.1, use stirrups spaced at 0.000 in
Between 4.32 to 4.99 ft, PhiVc Vu, Req'd Vs 0.87 25, use stirrups spaced at 7.000 in
1, Maximum Stresses for Load Combinations
Calculations per ACI 318 -08, IBC 2009, CBC 2010, ASCE 7 -05
Flange Thickness 6.0 in
144 at 8.0 in from Top, from 0.0 to 5.0 ft in this span
Job
Printed: 1 MAY 2012, 3:36PM
Service loads entered. Load Factors will be applied for calculations.
Maximum Deflection
Max Downward L +Lr +S Deflection
Max Upward L +Lr +S Deflection
Max Downward Total Deflection
Max Upward Total Deflection
Support notation Far left is #1
Desi; n OK
0.004 in Ratio
0.000 in Ratio
0.005 in Ratio
0.000 in Ratio
30 of 34
13802
0 <360
11826
999
Description
Load Combination
Hodge Engineering, Inc.
2615 Jahn Ave NW
Suite E5
IIIW Gig Harbor, WA
c17.•ginoc :.nc ark 1 Yli,, 253- 857 -7055
Ho
ea
Bending Stress Results (k -ft
Point load on continuous foundation
Title
Engineer:
Project Desc.:
Lic. KW- 06007122 �t Licensee HODGE ENGINEERING INC
onc re
ENERCALCINC.,1983- 2011, Build :6.12.314, Ver:6.12.3.14"
Location (ft)
Segment Length Span in Span Mu Max phi *Mnx Stress Ratio
MAXimum BENDING Envelope
Span 1 1 2.500 17.98 21.35 0.84
+1.40D
Span 1 1 2.500 2.82 21.35 0.13
+1.20D+0.50Lr +1.60L +1.60H
Span 1 1 2.500 16.42 21.35 0.77
+1.20D +1.60L+0.50S +1.60H
Span 1 1 2.500 17.98 21.35 0.84
+1.20D +1.60Lr+0.50L
Span 1 1 2.500 679 21.35 0.32
+1.20D+0.50L +1.60S
Span 1 1 2.500 11.79 21.35 0.55
+1.20D +1.60S+0.80W
Span 1 1 2.500 7.42 21.35 0.35
+1.20D+0.50Lr+0.50L +1.60W
Span 1 1 2.500 6.79 21.35 0.32
+1.20D+0.50L+0.50S +1.60W
Span 1 1 2.500 8.36 21.35 0.39
+1 .20 D+O.50 L+O.20 S+E
Span 1 1 2.500 7.42 21.35 0.35
Overall Maximum Deflections .Urifactored Loads
Load Combination Span Max. Defl Location in Span
Load Combination
Job
Printed: 1 MAY 2012, 3•36PM
Max. Defl Location in Span
D+L +S 1 0.0051 2.450 0.0000 0.000
31 of 34
Lic. KW- 06007122'
ncre
Description
aterlal P roperties
f c 2.50 ksi
fr= fc 7.50 375.0 psi
y/ Density 145.0 pcf
LtWt Factor
Elastic Modulus
fy Main Rebar
E Main Rebar
Ho
1.0
3,122.0 ksi
Load Combination 2006 IBC ASCE 7 -05
ross Section_& Reinforrcing'Details
Inverted Tee Section, Stem Width 8.0 in, Total Height= 24
Span #1 Reinforcing....
2-#4 at 3.0 in from Bottom, from 0.0 to 4,0 ft in this span
144 at 3.0 in from Top, from 0.0 to 4.0 ft in this span
A'pplted Loads
Beam self weight calculated and added to Toads
Load for Span Number 1
Uniform Load D 0.50, S 1.0 k /ft, Tributary Width= 1.0 ft
Point Load: L= 12.0 k 0 2.0ft
D ESIGN SUMMARY'
Maximum Bending Stress Ratio 0.691: 1
Section used for this span Typical Section
Mu Applied 22.019 k -ft
Mn Phi Allowable 31.852 k
Load Combination
Location of maximum on span
Span where maximum occurs
Vertical Reactions.,
Overall MAXimum
D Only
L Only
S Only
L +S
D+L
D +S
D+L +S
MAXimum BENDING Envelope
Span 1 1
Hodge Engineering, Inc.
2615 Jahn Ave NW
Suite E5
Gig Harbor, WA
C n g a n c c': n' I n c 253- 857 -7055
Point load on continuous foundation two story
d Phi Values
R1
Fy Stirrups
40.0 ksi E Stirrups
29,000.0 ksi Stirrup Bar Size
Number of Resisting Legs. Per Stirrup
Load Combination Support 1
9.516
1.516
6.000
2.000
8.000
7.516
3.516
9.516
Shear Stirrup Requirements
Entire Beam Span Length PhiVc/2 Vu PhiVc,
17 M aximum Forces' &.Stresses for Load
Load Combination
Segment Length Span in Span
+1 .20 D +1.60 L+0.50 S +1.60 H
2.000 ft
Span 1
Support 2
9.516
1.516
6.000
2.000
8.000
7.516
3.516
9.516
Location (ft)
2.000 22.02
Flexure
Shear:
40.0 ksi
29,000.0 ksi
3
2
0.90
0.750
0.850
8 "wx24 "h
Span =4.0 ft
Title
Engineer:
Project Desc.:
Support notation Far left is #1
Req'd Vs Not Reqd 11.5.6.1, use stirrups spaced at
Combinations
Bending Stress Results (k -ft
Mu Max Phi *Mnx Stress Ratio
31.85 0.69
e: c IUsers\John` Data Files \foundation ec6
ENERCALC,KINC.' 1983 -2011 BuiId,6.12,3A4;Ver6.12.
'L "see,:: ENGINEERING INC'
Calculations per ACI 318 -08, IBC 2009, CBC 2010, ASCE 7 -05
0.000 in
Maximum Deflection
Max Downward L +Lr +S Deflection
Max Upward L +Lr +S Deflection
Max Downward Total Deflection
Max Upward Total Deflection
Job
Printed: 1 MAY 2012, 3:48PM
.0 in, Top Flange Width 16.0 in, Flange Thickness 8.0 in
1-#4 at 12.0 in from Top, from 0.0 to 4.0 ft in this span
Service Toads entered. Load Factors will be applied for calculations.
si.n4
0.000 in Ratio
0.000 in Ratio
0.000 in Ratio
0.000 in Ratio
.32 of 34
0 <360
0 <360
999
999
D+L +S
Hodge Engineering, Inc.
2615 Jahn Ave NW
Suite E5
IIW Gig Harbor, WA
engiri�C__PYc irii„ 253- 857 -7055
Description
Load Combination
Segment Length
Ho
Licensee HODGE ENGINEERING INC
Point load on continuous foundation two story
Location (ft)
Span in Span
+1.40D
Span 1 1 2,000
+1.20D+0.50Lr +1.60L +1.60H
Span 1 1 2.000
+1.20D +1.60L+0.50S +1.60H
Span 1 1 2.000
+1.20D +1.60Lr+0.50L
Span 1 1 2.000
+1.20D+0.50L +1.60S
Span 1 1 2.000
+1.20D +1.60S+0.80W
Span 1 1 2.000
+1.20D+0.50Lr+0.50L +1.60W
Span 1 1 2.000
+1.20D+0.50L+0.50S +1.60W
Span 1 1 2.000
+1.20D+0.50L+0.20S+E
Span 1 1 2.000
1
2.12
21.02
22.02
7.82
11.02
5.02
7.82
8.82
8.22
Overall Maximum Deflections ,Unfactored Loads;;
Load Combination Span Max. Defl
Bending Stress Results (k -ft
Title
Engineer:
Project Desc.:
Mu Max Phi *Mnx Stress Ratio
Location in Span
0.0010 2.040
31.85 0.07
31.85 0.66
31.85 0.69
31.85 0.25
31.85 0.35
31.85 0.16
31.85 0.25
31.85 0.28
31.85 0.26
Job
Printed: 1 MAY 2012, 3:48PM
ile: c IUsers\John Hodge \Do cuments\ENERCALC Data Files\foundation calcs e66
ENERCALC, INC;1983 -2011, Build 6.12.3:1 Ver.6.12.3.14
Load Combination Max. Defl Location in Span
0.0000 0.000
33 of 34
Items with are re•uired.
Description of Problem:
Mailing Address:
Billing Address:
ongineerin inc.
Please complete the information below, sign this request form, and fax to:
Hodge Engineering at 253 857 -7599
Client Request for Engineering Support
et1 nform
*Company:
*Contact: Fax:
*Hodge Engineering Proj Mobile:
Architect Plan Email Address:
*Site Address:
eject in formati
1 authorize the above requested work and associated charges.
Client Signature (ok to start Work):
Client Name (please print):
*Phone:
Hod •e use onl
2615 Jahn Ave NW Suite E5 Gig Harbor, WA 98335
Tel: 253 857 -7055 Fax: 253 857 -7599
www.hodoeenc 3 a.com
PREPAF,D 4/01/13, 11:45:20 INSPECTION HISTORY REPORT PAGE 1
PROGRAM BP521L 0 /00 /00 THRU 0 /00 /00
CITY OF PORT ANGELES
APPLICATION PROPERTY ADDRESS
ASSESSOR PARCEL NUMBER ALTERNATE ID
STRUCTR PERMIT INSPECTION RESULT DATE /STATUS INSPECTOR
12 00001199 1302 P ST 06- 30- 01 -8 -0- 0150 -0000- 063001800150
000 000 BPR 00 BUILDING PERMIT RESIDENTIAL BLFW 0001 BLDG FOUND FTG /STEM WALL 10/25/12 APPROVED JLL
REQ COMM: October 25, 2012 8:45:44 AM pbarthol.
REQ COMM: James 253 686 -6132
REQ COMM:
REQ COMM: LATE AM
RES COMM: October 25, 2012 4:01:.26 PM jlierly.
000 000 BPR 00 BUILDING PERMIT RESIDENTIAL BFF 0001 BLDG FLOOR FRAMING 11/01/12 APPROVED JLL
REQ COMM: November 1, 2012 8:18:39 AM pbarthol.
REQ COMM: Karl 253- 906 -4585
RES COMM: November 1, 2012 4:27:14 PM jlierly.
000 000 BPR 00 BUILDING PERMIT RESIDENTIAL BLHD 0001 BLDG FRAMING HOLD DOWNS 11/08/12 APPROVED JLL
REQ COMM: November 9, 2012 2:36:55 PM jlierly.
RES COMM:
000 000 BPR 00 BUILDING PERMIT RESIDENTIAL
REQ COMM:
RES COMM:
BLSH 0001 BLDG SHEATHING 11/08/12 APPROVED
November 9, 2012 2:37:27 PM jlierly.
000 000 BPR 00 BUILDING PERMIT RESIDENTIAL BL3 0001 BLDG FRAMING 11/30/12 APPROVED
REQ COMM: November 30, 2012 1:20:27 PM jlierly.
RES COMM: November 30, 2012 1:21:49 PM jlierly.
000 000 BPR 00 BUILDING PERMIT RESIDENTIAL BAIR 0001 BLDG AIR SEAL 12/04/12 APPROVED
REQ COMM: December 4, 2012 8:13:41 AM pbarthol.
REQ COMM: Darren 253- 255 -4097
RES COMM: December 4, 2012 3:54:19 PM pbarthol.
000 000 BPR 00 BUILDING PERMIT RESIDENTIAL BLI 0001 BLDG INSULATION 12/06/12 APPROVED
REQ COMM: December 6, 2012 3:28:00 PM pbarthol.
REQ COMM: paul 253 272 -5300
RES COMM: December 6, 2012 4:06:44 PM pbarthol.
000 000 BPR 00 BUILDING PERMIT RESIDENTIAL BLDR 0001 BLDG DRYWALL IBWP 12/11/12 APPROVED JLL
REQ COMM: December 11, 2012 8:26:01 AM pbarthol.
REQ COMM: Darrell 253- 255 -4097
REQ COMM: Please call and let him know if it passed the inspection
RES COMM: December 11, 2012 4:47:56 PM jlierly.
000 000 BPR 00 BUILDING PERMIT RESIDENTIAL FFNL 0001 FIRE FINAL 3/01/13 APPROVED
REQ COMM: March 1, 2013 9:12:03 AM dchastai.
RES COMM: March 1, 2013 9:13:40 AM dchastai.
000 000 BPR 00 BUILDING PERMIT RESIDENTIAL BL99 0001 BLDG FINAL 3/07/13 APPROVED
REQ COMM: March 7, 2013 10:29:38 AM pbarthol.
REQ COMM: Paul 253- 272 -5300
RES COMM: March 7, 2013 4:15:43 PM jlierly.
000 000 BPR 00 BUILDING PERMIT RESIDENTIAL PW99 0001 PUBLIC WORKS FINAL 3/07/13 APPROVED
REQ COMM: March 7, 2013 3:20:31 PM rvess.
JLL
JLL
PB
PB
DRC
JLL
RV
.x PREPA' D 4/01/13, 11:45:20
PROGRAM BP521L
CITY OF PORT ANGELES
INSPECTION HISTORY REPORT
0 /00 /00 THRU 0 /00 /00
PAGE 2
APPLICATION PROPERTY ADDRESS ASSESSOR PARCEL NUMBER ALTERNATE ID
STRUCTR PERMIT INSPECTION RESULT DATE /STATUS INSPECTOR
12 00001199 CONTINUED
RES COMM: March 7, 2013 3:20:50 PM rvess.
000 000 ME 00 MECHANICAL PERMIT ME1 0001 MECHANICAL ROUGH -IN 11/30/12 APPROVED JLL
REQ COMM: November 30, 2012 1:20:56 PM jlierly.
RES COMM: November 30, 2012 1:21:49 PM jlierly.
000 000 ME 00 MECHANICAL PERMIT ME99 0001 MECHANICAL FINAL 3/07/13 APPROVED JLL
REQ COMM: March 7, 2013 10:30:04 AM pbarthol.
REQ COMM: Paul 253- 272 -5300
RES COMM: March 7, 2013 4:15:43 PM jlierly.
000 000 PL 00 PLUMBING PERMIT PL6 0001 PLUMBING WATER SUPPLY 10/30/12 APPROVED JLL
REQ COMM: October 30, 2012 12:49:00 PM jlierly.
RES COMM: October 30, 2012 4:23:11 PM jlierly.
000 000 PL 00 PLUMBING PERMIT PL2 0001 PLUMBING ROUGH -IN 11/30/12 APPROVED JLL
REQ COMM: November 30, 2012 1:21:22 PM jlierly.
RES COMM: November 30, 2012 1:21:49 PM jlierly.
000 000 PL 00 PLUMBING PERMIT PL99 0001 PLUMBING FINAL 3/07/13 APPROVED JLL
REQ COMM: March 7, 2013 10:30:14 AM pbarthol.
REQ COMM: Paul 253- 272 -5300
RES COMM: March 7, 2013 4:15:43 PM jlierly.
000 000 SSHU 00 SANITARY SEWER HOOK UP PW2 0001 PUBLIC WORKS SEWER CONNEC 10/30/12 APPROVED RV
REQ COMM: January 7, 2013 7:49:02 AM rvess.
RES COMM: January 7, 2013 7:49:25 AM rvess.
8
RECEIVED .�`�� YjSN�,�
CITY OF PORT ANGELES PERMIT APPLICATION`
MAY 11. 2015
r®)
a
Building .Division /Electrical Inspections
�►
321 East Fifth Street -- P.O. Box 1150 / Port Angeles Washington, 98362 ELECTRICAL
RICAL
Ph: (360) 417 -4735 Fax: (360) 417 -4711 INSPECTIONS
Date: S FS-1 _ 1 & 2 Single Family Dwelling
* Plan Review May Be Iletred, Please Complete Electrical Plan Review Information Sheet
p
Job Address: �
Building Square Footage; V00 I
DesaCi tion f above Q S
-
-
Owner 1 formatlat Contractor Information
Name: Gam/ Name:
Mailin Address: d Mailing Address:
City: \r CQ.vvae e_Q ttaate Zip: �$� City: State
Zip:
Phon ' Phone: Fax:
License # 1 Exp, License # ! Exp.
Item Unit Charge (qty Total (Qty Multiplied by Unit Char gel
Service/Feeder 200 Amp. $120.00
$
Service/Feeder 201 -400 Amp. $146.00
$
ServicelFeeder 401.600 Amp $ 205.00
$
Service/Feeder 601.1000 Amp. $ 262.00
$
ServicelFeeder over 1000 Amp. $ 373.00
$
Branch Circuit Wl Service Feeder $ 5.00
$
Branch Circuit W/O Service Feeder $ 63.00
Each Additional Branch Circuit $ 5,00
$
Branch Circuits 1 -4 $ 75.00 _
$
Temp. Service/ Feeder 200 Amp. $ 93,00
$ __
Temp, Service/Feeder 201 -400 Amp $110.00
$
Temp. Service/Feeder 401 -600 Amp $149.00
$
Temp. Service/Feeder 601 -1000 Amp , $168.00
$
Portal to Portal Hourly $ 96.00
$
Signal Circuit/ Limited Energy -1 & 2 Family Dwelling $ 64.00
$
Manufactured Home Connection $120.00
$
Renewable Electrical Energy - 5KVA System or Less $102.00 _
$
Thermostat $ 56.00 _
$
Note; $5,00 for each additiorai T -Stat
NEW CONSTRUCTION ONLY:
First 1300 Square Ft. $120,00
$
Each Additional 500 Square Ft. or Portion of $ 40,00
$
Each Outbuilding or Detached Garage $ 74.00 1
$
Each Swimming Pool or Hot Tub $11000
$
$ Total
Owner as defined by RCW.19.28,261: (1) Owner will occupy the structure for two years after this electrical permit
is finalized, (2) Owner is required
to hire an electrical contractor if above said property is for sale, rent or lease, Permit expires after six months of last
inspection,
After reading the above statement, I hereby certify that I am the owner of the above named property or a licensed
electrical contractor. I am making
the electrical installation or alteration in compliance with the electrical laws, N.E,C,, RCW. Chapter 19.28, WAC. Chapter 296 -4613, The City of Port
Angeles Municipal Code, and Utility Specifications and PAMC 14,05,050 regarding Electrical Permit Applications.
Signature of owner, electrical contractor or electrical administrator: ❑ Cash ❑ check
❑ Credit Card #
�� S
x Dated: —.
0110112012
ELECTRICAL PERMIT
CITY OF PORT ANGELES
360 -417 -4735
Application Number . . . . T5- 00000503 Date 5/12/15
Application pin number 625512
Prcperty•Address 1302 P ST
ASSESSOR PARCEL NUMBER; 05-30-01-8-0- 0150 -0000-
Application type description ELECTRICAL ONLY
Subdivision Name
Property Use . , . . . . . .
Property Zoning . , . . . , . RS9 RESONTL SINGLE FAMILY
Application valuation . . . . 0
Application desc
New detached garage
Owner Contractor
------------------------
RAYMOND LEE. /NANCY KAY SILCOX OWNER
1302 P ST
PORT ANGELES WA 98363
Permit . . . . . ELECTRICAL NEW RESIDENTIAL
Additional desc .
Permit Fee . . . 74.00 Plan Check Pee .00
Issue Date , . . . 5/12/15 Valuation , , , . 0
Expiration Date 11/08/15
Qty Unit Charge Per Extension
1.00 74.0000 ECH 'EL- R- OUT3D /DTCH GAR IN /SEP 74.00
Fee summary Charged Paid Credited Due
Permit Pee Total 74,00 74.00 ,00 ,00
Plan Check Total DO OO 00 .00
Grand Total 74.00 74.00 .00 .00
REPORT SALES TAX
on your excise tax form
to the City of Port Angeles
(Location Code 0502)
INSPECTION TYPE
DATE:
RESULTS:
INSPECTOR:
DITCH
SERVICE
ROUGII -IN
FINAL
V
COMMENTS:
PEA MIT WILL EXP=L SIX (6) MONTHS FROM LAST INSPECTION
Signature of owner or Electrical Contractor X
G: IEXCHANGEIBUILDING