HomeMy WebLinkAbout306 W 3rd St - Building RECEIV
iCiTy IMF PORT.ANGELES.PERmrr APPI.IcAnm JUN 2 6 1
2013
Building Division/Electric tl.Inspections
321 East Fifth Street—P.O.Box 11501 Port Angeles Washington,98362
Ph:(360)417-4735 Fax-('350)417-471€ INSPECTIONS
�
INS��'t��'f0�S
Date: lam:_: t /1&2 Single Family DmIling
Plan Review May Be Retired,Please Complete Electrical Plan Review Information Sheet
Job Address: 7
SuVding Square Footage;
Descr plion of above frv..z i t_3 at r. s -
Owner info titan Contractor Information .
Name: �4�Y t�:o i1 �,�� _ Name:4LX&4 r1�oLe 1 e'-h j let4*4
Mailing Address: "r.; MaIIing Address: Y1 E,_9MCAff
City: "°' State:�i!t Zrn .. _ _ city: ? 4 . Slime_WA-21p: 149%2_
Phone: �� _
license#1 xp. t.icense#1Fxp XT!!�,+m7-4�Rr.
Item Unit Chartte d,�,,t Total M ltl ll d b unit Gh sr e
Servicelf-aeder20UAmp, $120,00 ____
Service/Feeder 201-400 Amp. $146.00
ServicelFeeder 401-600 Amp $205,00
ServicslFeeder 601-11700 Amp. $262.00 $_
SarvicelFeedar over 1000Amp. $573.06
BramhCircuaVVI Service Feeder $ 5.06 $�—_--
Branch Circuit VV/0 Service Feeder $ 63,00 Y Each Additional Additional Branch Circuit $ 5,00 $�
Branch Circuits 14 $ 75,60
Temp.Servtael Feeder 200 Amp. $ 93.00 °---
Temp,Serviceifeeder 201400 Amp. $110.00 $.-
Tamp.ServicelFeeder4ol- O Amp. $149,00 $ -A
Temp.Service/Feeder 6101-1000 Amp. $168.00 _� $
Portal to Portal Hourly $ 96.00 � $�
Signal Circuit/Limited Energy-1&2 C artlily Dwelling $ 64.00
Manufactured Home Connection $1200.00 $
Renewable Electrical Energy.5KVA System or less '$102.00 $
Thermostat $ 56.00 _-
Note:$5.00 for each additional T-.Stat
NSW ONSTR1:CTION ONLY
First 1300 Square Ft. $120.00
Each Additional 500 Square F1,or PorlJon of $ ,40,00
Each Outbuilding or Detadk Game $ 74.00
Each Swimming Pool or Hot Tub $'110.00 � $ _
$�Total
Owner as defined by RM 19.28.261:(1)Owner Will occupy the stricture for two years after this electrical permit is finalized.(2)Owner is required
to hire an electrical contractor if above said property is for sale,rent or lease.Permit expires after six months of last inspect€on.
After reading the above statement,I hereby certify that 1 am the owner of the above named property or a licensed electrical contractor.I am making
the eleolricai installation or alter Lion in compliance with the electrical laws,N.E.C.,RCw.Chapter 19.28,WAC.Chapter 296468,The City of Port
Angeles Municipal Cade,and t3triity Spec"rfications and PAMC 14,05.050 regarding Electrical Permit Applications.
Signature of o er electrical cointmctor or electrical administrators 0 ca'sh Q chat
17 CMMcW0
naraa: �. etrrr�rzll�x��
ELECTRICAL PERMIT
CITY OF PORT ANGELES 1
360-417-4735
Application Number , , , , , 13-00000698 Date 6/26/13
Application pin number . . . 672968
Property Address , . . . , 306 W 3RD ST REPORT SALES TAX
ASSESSOR PARCEL NUMBERr 06-30-00-0-D-7205-0000- [ "�
Application type description ELECTRICAL ONLY on your excise tax form !l
Subdivision. Name . . . . to the City of Port Angeles
Property Use
Property Zoning , . . . , , . RESIDENTTA5 HIGH DENSITY (Location Code 0502)
Application valuation , . , . 0
Application desc
Ductless heat pump, wire repairs attic
Owner Contractor
CAROLYN WILCOX AND LINDSEY SCH EXTRA MTLF TECH & ELECT. , LLC � �1
306 W 3RD ST 418 N, RACE ST. J�
PORT ANGELES WA 98362 PORT ANGELES WA 98362
(360) 457`0198
-------------------------- .__---- -------------------
Permit , . . , . . ELECTRICAL ALTER RESIDENTIAL
Additional desc 1-4 CIRCUITS
Permit Fee 75.00 Plan Check Fee .00
Issue Date 6/26/13 Valuation , , , , 0
Expiration Date 12/23/13
Qty Unit Charge Per Extension
BASE F'E'E 75.00
-------------------------------- -
Fee summary Charged Paid Credited Due
Permit Fee Total 75,00 75,00 .00 .00
Plan Check Total .DO 00 .00 .00
Grand Total 75.00 75.OD 00 .00
INSPECTION TYPE DATE: RESULTS: INSPECTOR:
DITCH
SERVICE
ROUGH-1N I
Ae AR)
FINAL ,
COMMENTS:
PERMIT WILL EXPIRE SIX(6)MONTHS FROM LAST INSPECTION
Signature of owner or Electrical Contractor X Date:
c-A1HxCr-1nNOFNiuILDING
Public Works and Utilities Department
321 E. 5th Street, Port Angeles, WA 98362
360.417.4735 | www.cityofpa.us | electricalpermits@cityofpa.us
EL1-2 SF 1 - 2 SINGLE-FAMILY
ELECTRICAL PERMIT APPLICATION
Project Address:
Project Description: □Single-Family Residential □ Duplex / ARU Building Square footage:
OWNER INFORMATION
Name: Email:
Mailing Address: Phone:
ELECTRICAL CONTRACTOR INFORMATION
Name: License:
Mailing Address: Expiration Date:
Email: Phone:
PROJECT DETAILS
Item Unit Charge Quantity Total (Quantity x Unit Charge)
Service/Feeder 200 Amp.$120.00 $
Service/Feeder 201-400 Amp.$146.00 $
Service/Feeder 401-600 Amp.$205.00 $
Service/Feeder 601-1000 Amp.$262.00 $
Service/Feeder over 1000 Amp.$373.00 $
Branch Circuit W/ Service Feeder $5.00 $
Branch Circuit W/O Service Feeder $63.00 $
Each Additional Branch Circuit $5.00 $
Branch Circuits 1-4 $75.00 $
Temp. Service/Feeder 200 Amp.$93.00 $
Temp. Service/Feeder 201-400 Amp.$110.00 $
Temp. Service/Feeder 401-600 Amp.$149.00 $
Temp. Service/Feeder 601-1000 Amp.$168.00 $
Portal to Portal Hourly $96.00 $
Signal Circuit/Limited Energy - 1&2 DU.$64.00 $
Manufactured Home Connection $120.00 $
Renewable Elec. Energy: 5KVA System or less $102.00 $
Thermostat (Note: $5 for each additional)$56.00 $
First 1300 Square Feet $120.00 $
Each Additional 500 square feet``$40.00 $
Each Outbuilding / Detached Garage $74.00 $
Each Swimming Pool / Hot Tub $110.00 $
TOTAL $
Owner as defined by RCW.19.28.261: (1) Owner will occupy the structure for two years after this electrical permit is finalized. (2) Owner is
required to hire an electrical contractor if above said property is for sale, rent or lease. Permit expires after six months of last inspection.
After reading the above statement, I hereby certify that I am the owner of the above named property or a licensed electrical contractor. I
am making the electrical installation or alteration in compliance with the electrical laws, N.E.C., RCW. Chapter 19.28, WAC. Chapter 296-
46B, The City of Port Angeles Municipal Code, and Utility Specifications and PAMC 14.05.050 regarding Electrical Permit Applications.
Date Print Name Signature (□Owner □Electrical Contractor / Administrator)Permit #: New
Construction
Only
[Electrical Permit Applications may be submitted to City Hall or epermits@cityofpa.us or faxed to 360.417.4711]
PREPARED 8/15/23, 8:08:05 PAYMENT DUE
CITY OF PORT ANGELES PROGRAM BP820L
---------------------------------------------------------------------------
APPLICATION NUMBER:23-00000876 306 W 3RD ST
FEE DESCRIPTION AMOUNT DUE
---------------------------------------------------------------------------
ELECTRICAL ALTER RESIDENTIAL 248.00
TOTAL DUE 248.00
Please present reciept to the cashier with full payment
LINDSEY SCHROMEN-WAWRIN
RESPONSE LETTER
Listed below are the revisions we have made to the design and engineering letter document for
our residential solar installation for LINDSEY SCHROMEN-WAWRIN.
Design Page 2:SITE PLAN
•Updated and reflected the changes of the panel's placement.
Design Page 3 &4:ROOF ATTACHMENTS &MOUNTING DETAIL
•Updated the equipment information.
AERIAL VIEW:MAP VIEW:
GENERAL NOTES
1. INSTALLATION OF SOLAR PHOTOVOLTAIC SYSTEM SHALL BE IN ACCORDANCE WITH NEC ARTICLE
690, AND ALL OTHER APPLICABLE NEC CODES WHERE NOTED OR EXISTING
2. PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL
EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110
3. ALL WIRES, INCLUDING THE GROUNDING ELECTRODE CONDUCTOR SHALL BE PROTECTED FROM
PHYSICAL DAMAGE IN ACCORDANCE WITH NEC ARTICLE 250
4. THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE; THIS SYSTEM IS UTILITY INTERACTIVE PER
UL 1741 AND DOES NOT INCLUDE STORAGE BATTERIES OR OTHER ALTERNATIVE STORAGE SOURCES
5. ALL DC WIRES SHALL BE SIZED ACCORDING TO [NEC 690.8]
6. DC CONDUCTORS SHALL BE WITHIN PROTECTED RACEWAYS IN ACCORDANCE WITH [NEC 690.31]
7. ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL JURISDICTIONAL BUILDING CODE
PHOTOVOLTAIC (PV) SYSTEM SPECIFICATIONS
APPLICABLE GOVERNING CODES
SITE SPECIFICATIONS
OCCUPANCY: R-3
ZONING: RESIDENTIAL
COVER PAGE - PV01
SITE INFORMATION
LINDSEY SCHROMEN-WAWRIN
306 W 3RD ST
PORT ANGELES, WA 98362
DC System Size: 6.40 kW DC
Lat, 48.11890
Long, -123.43968
(16) VSUN 400-108BMH (400W)
PV Modules
Inverter(s)
UTILITY: CITY OF PORT ANGELES
DRAWN BY: M. BOBO
DATE:
6/14/2023
9981 West 190th St
Unit K Mokena IL 60448
T: 708-995-1643
Revolution Energy Systems Inc.
(4)HOYMILES HM-1200N (240V)
(2) HOYMILES HM-300N (240V)
AC System Size: 5.40 kW AC / 5.40 kVA
AHJ: CITY OF PORT ANGELES
2020 NEC
2018 IRC
2018 IMC
2018 IFGC
EQUIPMENT:
AC System Size: 5.40 kW AC / 5.40 kVA
DC SYSTEM SIZE: 6.40 kW DC
(16)VSUN 400-108BMH (400W) PV Modules
(4)HOYMILES HM-1200N (240V) Inverters
(2) HOYMILES HM-300N (240V) Inverters
RACKING: S-5! MINI/S BRACKET - 48" O.C.
SHEET INDEX:
PV01 COVER PAGE
PV02 SITE PLAN
PV03 ROOF ATTACHMENTS
PV04 MOUNTING DETAIL
PV05 LINE DIAGRAM
PV06 ELECTRICAL CALCS
PV07 LABELS
PV08 PLACARD
PV09 SITE PHOTOS
DESIGN CRITERIA
SNOW LOAD: 25 PSF
WIND SPEED: 110 MPH
AC
M
MS
P
LC
JB
PV
AC
M
MS
P
LC
JB
PV
SITE INFORMATION
LINDSEY SCHROMEN-WAWRIN
306 W 3RD ST
PORT ANGELES, WA 98362
DC System Size: 6.40 kW DC
Lat, 48.11890
Long, -123.43968
(16) VSUN 400-108BMH (400W)
PV Modules
Inverter(s)
UTILITY: CITY OF PORT ANGELES
DRAWN BY: M. BOBO
DATE:
6/14/2023
9981 West 190th St
Unit K Mokena IL 60448
T: 708-995-1643
Revolution Energy Systems Inc.
(4) HOYMILES HM-1200N (240V)
(2) HOYMILES HM-300N (240V)
AC System Size: 5.40 kW AC / 5.40 kVA
AHJ: CITY OF PORT ANGELES
SITE PLAN - PV02
MOUNTING PLANE:
MP1
ARRAY DETAILS:
AZIMUTH:
212°
TILT:
30°
MP2 32°30°
VISIBLE, LOCKABLE,
LABELED AC DISCONNECT
LOCATED WITHIN 10'
OF UTILITY METER
CLOSE UP OF HOUSE
MSP
M UTILITY METER
PV
AC VISIBLE, LOCKABLE, LABELED
AC DISCONNECT
METER SOCKET
(For utility PV meter)
INV
C
INVERTER
EQUIPMENT LEGEND:
SUB PANEL
COMBINER BOX LC BATT
MSD
JB
PV MODULES
PROPERTY LINE
SUB
LOAD CENTER BATTERY(IES)JUNCTION BOXMAIN SERVICE
PANEL
MAIN SERVICE
DISCONNECT SS SMART SWITCH
(IQ System Controller)
FIRE ACCESS
PATHWAY (3' TYP)
ATS AUTOMATIC
TRANSFER SWITCH
D
R
I
V
E
W
A
Y
P
R
O
P
E
R
T
Y
L
I
N
E
~
4
0
'
-
1
'
'
W
3
R
D
S
T
P
R
O
P
E
R
T
Y
L
I
N
E
~
4
0
'
-
1
'
'PROPERTY LINE ~133'-7''PROPERTY LINE ~133'-9''MP1
MP2
90'-4"
7'-3"
2'-6"
1'-10"
AC
M
MS
P
LC
JB
PV
SITE INFORMATION
LINDSEY SCHROMEN-WAWRIN
306 W 3RD ST
PORT ANGELES, WA 98362
DC System Size: 6.40 kW DC
Lat, 48.11890
Long, -123.43968
(16) VSUN 400-108BMH (400W)
PV Modules
Inverter(s)
UTILITY: CITY OF PORT ANGELES
DRAWN BY: M. BOBO
DATE:
6/14/2023
9981 West 190th St
Unit K Mokena IL 60448
T: 708-995-1643
Revolution Energy Systems Inc.
(4) HOYMILES HM-1200N (240V)
(2) HOYMILES HM-300N (240V)
AC System Size: 5.40 kW AC / 5.40 kVA
AHJ: CITY OF PORT ANGELES
ROOF ATTACHMENTS - PV03
PV MODULE COUNT:
ARRAY AREA:
ROOF AREA:
16
PERCENT OF ROOF COVERED:
ARRAY WEIGHT:
POINT LOAD:
DISTRIBUTED LOAD: (lbs/ft²)
1237.24 ft²
27%
MODULE COUNT * 21.02 ft² = 336.32
MODULE COUNT * 47.18 lbs = 754.88 lbs
ARRAY LBS/ATTACHMENTS = 20.97
(ARRAY) WEIGHT/AREA = 2.2 lbs/ft²
PHOTOVOLTAIC ARRAY STRUCTURAL CRITERIA:
HOUSE ELEVATION
EQUIPMENT INFORMATION:
RAIL MANUFACTURER:
RAIL PART NUMBER:
ATTACHMENTS
ATTACHMENT QTY:
SPLICE QTY:
MIDCLAMP QTY:
ENDCLAMP QTY:
CHIKO
7-RB
S-5! MINI/S BRACKET
36
8
36
21
ROOF TYPE:
ROOF FRAMING:
RAFTER/TOP CHORD SIZE:
RAFTER/TOP CHORD SPACING:
ATTACHMENT SPACING:
ROOF INFORMATION
METAL ROOF
MANUFACTURED TRUSS
2" X 4"
24"
48"
34'-11"
36'-1"
18" TYP
3' TYP
11'-9"
17'-6"
±12'-11"
±15'-11"
35'-9"
H O Y M I L E S M I C R O I N V E R T E R L E G E N D S :
HM-1200N ( 4 panels per 1 microinverter)
HM-300N (1 panel per 1 microinverter)
1-1
1-1
1-1
1-1
1-2
1-2
1-2
1-3
2-2
2-2
2-2
2-1
2-1
2-1
2-1
2-3
SITE INFORMATION
LINDSEY SCHROMEN-WAWRIN
306 W 3RD ST
PORT ANGELES, WA 98362
DC System Size: 6.40 kW DC
Lat, 48.11890
Long, -123.43968
(16) VSUN 400-108BMH (400W)
PV Modules
Inverter(s)
UTILITY: CITY OF PORT ANGELES
DRAWN BY: M. BOBO
DATE:
6/14/2023
9981 West 190th St
Unit K Mokena IL 60448
T: 708-995-1643
Revolution Energy Systems Inc.
(4) HOYMILES HM-1200N (240V)
(2) HOYMILES HM-300N (240V)
AC System Size: 5.40 kW AC / 5.40 kVA
AHJ: CITY OF PORT ANGELES
CHIKO
END CLAMP
CHIKO
MID CLAMP
1 2
PV MODULE
RAIL
PV MODULE
RAIL
PV MODULE
1'-8"
MAX.
RAIL FRONT VIEW
1 END CLAMP DETAILS 2 MID CLAMP DETAILS
RAIL
S-5 MINI/S BRACKET
10" MIN -
1'-4"
MAX
2'-8" MIN -
3'-10" MAX
(E) RAFTER/TOP CHORD
2'-8" MIN -
3'-10" MAX
3
10" MIN -
1'-4"
MAX
(E) RAFTER/TOP CHORDS
48" MAX SPAN
SIDE VIEW
3
DETAIL, MOUNTING
MOUNTING DETAIL - PV04
PV MODULE COUNT:
ARRAY AREA:
ROOF AREA:
16
PERCENT OF ROOF COVERED:
ARRAY WEIGHT:
POINT LOAD:
DISTRIBUTED LOAD: (lbs/ft²)
1237.24 ft²
27%
MODULE COUNT * 21.02 ft² = 336.32
MODULE COUNT * 47.18 lbs = 754.88 lbs
ARRAY LBS/ATTACHMENTS = 20.97
(ARRAY) WEIGHT/AREA = 2.2 lbs/ft²
PHOTOVOLTAIC ARRAY STRUCTURAL CRITERIA:EQUIPMENT INFORMATION:
RAIL MANUFACTURER:
RAIL PART NUMBER:
ATTACHMENTS
ATTACHMENT QTY:
SPLICE QTY:
MIDCLAMP QTY:
ENDCLAMP QTY:
CHIKO
7-RB
S-5! MINI/S BRACKET
36
8
36
21
ROOF TYPE:
ROOF FRAMING:
RAFTER/TOP CHORD SIZE:
RAFTER/TOP CHORD SPACING:
ATTACHMENT SPACING:
ROOF INFORMATION
METAL ROOF
MANUFACTURED TRUSS
2" X 4"
24"
48"
SITE INFORMATION
LINDSEY SCHROMEN-WAWRIN
306 W 3RD ST
PORT ANGELES, WA 98362
DC System Size: 6.40 kW DC
Lat, 48.11890
Long, -123.43968
(16) VSUN 400-108BMH (400W)
PV Modules
Inverter(s)
UTILITY: CITY OF PORT ANGELES
DRAWN BY: M. BOBO
DATE:
6/14/2023
9981 West 190th St
Unit K Mokena IL 60448
T: 708-995-1643
Revolution Energy Systems Inc.
(4) HOYMILES HM-1200N (240V)
(2) HOYMILES HM-300N (240V)
AC System Size: 5.40 kW AC / 5.40 kVA
AHJ: CITY OF PORT ANGELES
LINE DIAGRAM - PV05
TYPE:
MODULES:
INVERTERS:
AC DISCONNECTS:
QTY:
(16)
(1)
DESCRIPTION:
VSUN 400-108BMH 400
PV AC Disconnect, 240V, 2-Pole
RATING:
400 W
30 A
Equipment Schedule
PV AC DISCONNECT
30A VISIBLE, LOCKABLE,
LABELED, OPEN
240V, 2-POLE
N
G
1
(2)
(1)BARE CU - (GROUND)N/A - FREE AIR
2
(2)
(1)10 AWG (90°C)
THHN/THWN-2, COPPER - (L1, L2)
THWN-2 COPPER - (GROUND)
3/4" EMT
TAG QTY WIRE GAUGE
Conduit & Conductor Schedule
DESCRIPTION CONDUIT SIZE
VSUN 400-108BMH 400 Specs
POWER MAX (PMAX):
OPEN CIRCUIT VOLTAGE (VOC):
MAX POWER-POINT CURRENT (IMP):
MAX POWER-POINT VOLTAGE (VMP):
SHORT CIRCUIT CURRENT (ISC):
SERIES FUSE RATING:
400W
20A
37.2V
12.84A
31.17V
13.68A
(E)
G
(E) UTILITY METER
(E) GROUNDING
ELECTRODE
N
(E) LOADS
(N) 225A MAIN SERVICE PANEL
120/240 VAC
TO UTILITY GRID
(N) 30A-2P
(N) 200A-2P
HOYMILES HM-1200N (240V)1200 W(4)
HOYMILES : HM-1200N (240V) Specs
MAX INPUT VOLTAGE:
MAX INPUT CURRENT:
NOMINAL DC INPUT VOLTAGE:
MAXIMUM OUTPUT POWER:
NOM. OUTPUT VOLTAGE:
MAX OUTPUT CURRENT:
1-Phase, 60 HZ, UL 1741 Listed
60 V
20 A
60 V
1200 W
240 V
5.00 A
AC-CABLE , COPPER (L1, L2)
4
LOAD CENTER:(1)PV LOAD CENTER, NEMA 3R RATED
VISIBLE, LOCKABLE,
LABELED AC DISCONNECT
LOCATED WITHIN 10'
OF UTILITY METER
125 A
10 AWG (90°C)
12 AWG (90°C)
J-BOX
3
N
GND
2P - 20A
(N) 125A PV LOAD CENTER,
NEMA 3R RATED
J-BOX
4 MODULES
1-HM1200N
=
STRING (1): 20.0A (8 MODULES)
3 MODULES
1-HM1200N
=
1 2
J-BOX
=
STRING (2): 20.0A (8 MODULES)
=
1 2
4 MODULES
1-HM1200N
3 MODULES
1-HM1200N
690.12 RAPID
SHUTDOWN COMPLIANT
2P - 20A
1 MODULE
1-HM300N
=
=
1 MODULE
1-HM300N
EXCESS PORT WILL NEED TO BE CAPPED
EXCESS PORT WILL NEED TO BE CAPPED
INVERTERS:HOYMILES HM-300N (240V)300 W(2)
HOYMILES : HM-300N (240V) Specs
MAX INPUT VOLTAGE:
MAX INPUT CURRENT:
NOMINAL DC INPUT VOLTAGE:
MAXIMUM OUTPUT POWER:
NOM. OUTPUT VOLTAGE:
MAX OUTPUT CURRENT:
1-Phase, 60 HZ, UL 1741 Listed
60 V
20 A
60 V
300 W
240 V
1.25 A
12 AWG (90°C)
METER #: 12571
10 AWG (75°C)
10 AWG (75°C)
THHN/THWN-2, COPPER - (L1, L2, NEUTRAL)
THWN-2 COPPER - (GROUND)5
(3)
(1)
10 AWG (90°C)
10 AWG (90°C)
THHN/THWN-2, COPPER - (L1, L2, NEUTRAL)
THWN-2 COPPER - (GROUND)
3/4" PVC4
(3)
(1)
10 AWG (90°C)
10 AWG (90°C)
THHN/THWN-2, COPPER - (L1, L2)
THWN-2 COPPER - (GROUND)
3/4" EMT3
(4)
(1)
3/4" PVC
LOAD SIDE
UTILITY PV PRODUCTION
METER BASE
LINE SIDE
5 5
ELECTRICAL CALCS - PV06
SYSTEM OCPD CALCULATIONS
INVERTER MODEL(S):
# OF INVERTER(S):
(# OF INVERTERS) X (MAX OUTPUT CURRENT):
(# OF INVERTERS) X (MAX OUTPUT CURRENT) X 125% <= OCPD RATING
SITE INFORMATION
LINDSEY SCHROMEN-WAWRIN
306 W 3RD ST
PORT ANGELES, WA 98362
DC System Size: 6.40 kW DC
Lat, 48.11890
Long, -123.43968
(16) VSUN 400-108BMH (400W)
PV Modules
Inverter(s)
UTILITY: CITY OF PORT ANGELES
DRAWN BY: M. BOBO
DATE:
6/14/2023
9981 West 190th St
Unit K Mokena IL 60448
T: 708-995-1643
Revolution Energy Systems Inc.
(4) HOYMILES HM-1200N (240V)
(2) HOYMILES HM-300N (240V)
AC System Size: 5.40 kW AC / 5.40 kVA
AHJ: CITY OF PORT ANGELES
BUSBAR CALCULATIONS - 120% RULE
225A
200A
30A
(MAIN BUS RATING X 120%) - MAIN DISCONNECT RATING >= OCPD RATING
(225A X 1.2) - 200A = 70A, >= 30A, OK
PV OCPD RATING:
MAIN BUS BAR RATING:
MAIN DISCONNECT RATING:
PV OCPD RATING:
4
5.00A
HOYMILES HM-1200N (240V)
(22.50A X 1.25) = 28.13A <= 30A, OK
STRING CALCULATIONS
HOYMILES : HM-1200N (240V), HM-300N (240V)
MAX AC CURRENT
MICRO INVERTER(S) IN SERIES:
NOMINAL VOLTAGE / RANGE²:
MAX AC OUTPUT POWER:
ARRAY DC POWER:
TOTAL MAX AC CURRENT:
6400W
22.50A
STRING #1
(2) HM-1200N ; (1) HM-300N
2700W
STRING #2
211V - 264V
TAG QTY DESCRIPTION CONDUIT SIZE CONDUCTOR RATING
Conduit & Conductor Schedule
CONDUCTOR TEMP. RATE AMBIENT TEMP # OF CONDUCTORS
DERATE
CONDUCTOR RATING
W/DERATES CONDUIT FILLTEMP. DERATEWIRE GAUGE
10 AWG
10 AWG
3/4" EMT 40A 90°C 11.45%
THHN/THWN-2, COPPER - (L1, L2)
THWN-2 COPPER - (GROUND)25°C 1.0(1)
(2)
1 (1)
(2)12 AWG
BARE CU - (GROUND)N/A - FREE AIR 30A 90°C 25°C 1.04 N/A - FREE AIR 31.2A N/A - FREE AIR
2
10 AWG
10 AWG
3/4" EMT 40A 90°C
THHN/THWN-2, COPPER - (L1, L2)
THWN-2 COPPER - (GROUND)3 25°C 0.8
(4)
(1)
41.6A
AC-CABLE , COPPER (L1, L2)
14.06A
NUMBER OF CURRENT CARRYING CONDUCTORS
4-6
7-9
10-20
PERCENT OF VALUES
.80
.70
.50
GROUNDING & GENERAL NOTES:
1. PV INVERTER IS UNGROUNDED, TRANSFORMER-LESS TYPE.
2. DC GEC AND AC EGC TO BE SPLICED TO EXISTING ELECTRODE
3. ANY EXISTING WIRING INVOLVED WITH PV SYSTEM CONNECTION THAT IS FOUND TO
BE INADEQUATE PER CODE SHALL BE CORRECTED PRIOR TO FINAL INSPECTION.
4. JUNCTION BOX QUANTITIES, AND PLACEMENT SUBJECT TO CHANGE IN THE FIELD -
JUNCTION BOXES DEPICTED ON ELECTRICAL DIAGRAM REPRESENT WIRE TYPE
TRANSITIONS.
5. AC DISCONNECT NOTED IN EQUIPMENT SCHEDULE OPTIONAL IF OTHER
AC DISCONNECTING MEANS IS LOCATED WITHIN 10' OF SERVICE DISCONNECT.
INTERCONNECTION NOTES:
1. INTERCONNECTION SIZING, LIMITATIONS AND COMPLIANCE DETERMINED IN ACCORDANCE WITH [NEC
705.12], AND [NEC 690.64].
2. GROUND FAULT PROTECTION IN ACCORDANCE WITH [NEC 215.9], [NEC 230.95] AND [NEC 690.5]
3. ALL EQUIPMENT TO BE RATED FOR BACKFEEDING.
4. PV BREAKER TO BE POSITIONED AT THE OPPOSITE END OF THE BUSBAR RELATIVE TO THE MAIN BREAKER.
DISCONNECT NOTES
1. DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS OPENED THE CONDUCTORS
REMAINING LIVE ARE CONNECTED TO THE TERMINALS MARKED “LINE SIDE” (TYPICALLY THE UPPER TERMINALS)
2. AC DISCONNECT MUST BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BE LOCKABLE, AND BE A
VISIBLE-BREAK SWITCH
MAX OUTPUT CURRENT:
2
1.25A
HOYMILES HM-300N (240V)
20.00A 2.50A
(2) HM-1200N ; (1) HM-300N
2700W
211V - 264V
14.06A
12 AWG
10 AWG
10 AWG
35A 75°C 1.05
THHN/THWN-2, COPPER - (L1, L2, NEUTRAL)
THWN-2 COPPER - (GROUND)5
(3)
(1)25°C 1.0
90°C10 AWG
10 AWG
40A
THHN/THWN-2, COPPER - (L1, L2, NEUTRAL)
THWN-2 COPPER - (GROUND)4
(3)
(1)
25°C 1.03/4" PVC
3/4" PVC
1.04
1.04
1.04
33.28A
41.6A
36.75A
19.09%
16.04%
16.04%
RATED AC OUTPUT CURRENT:
NOMINAL OPERATING AC VOLTAGE:
PHOTOVOLTAIC AC DISCONNECT
240 V
7
LABELING NOTES:
1. LABELS CALLED OUT ACCORDING TO ALL COMMON CONFIGURATIONS. ELECTRICIAN TO DETERMINE EXACT
REQUIREMENTS IN THE FIELD PER CURRENT NEC AND LOCAL CODES AND MAKE APPROPRIATE ADJUSTMENTS.
2. LABELING REQUIREMENTS BASED ON THE 2020 NATIONAL ELECTRIC CODE, OSHA STANDARD 19010.145, ANSI
Z535.
3. MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION.
4. LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED [NEC 110.21(B)(3)]
5. LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8", WHITE ON RED BACKGROUND; REFLECTIVE, AND
PERMANENTLY AFFIXED [IFC 605.11.1.1]
5
(ONLY IF PV
INTERCONNECTION
CONSISTS OF LOAD
SIDE BREAKER)
3
5
(ONLY IF PV
INTERCONNECTION
CONSISTS OF LOAD
SIDE BREAKER)
9 1
6
INTEGRATED DC DISCONNECT
*ELECTRICAL DIAGRAM SHOWN ABOVE IS FOR LABELING PURPOSES ONLY. NOT AN ACTUAL REPRESENATION OF EQUIPMENT AND CONNECTIONS TO BE INSTALLED. LABEL LOCATIONS
PRESENTED MAY VERY DEPENDING ON TYPE OF INTERCONNECTION METHOD AND LOCATION PRESENTED ON THE ELECTRICAL DIAGRAM PAGE.
6
4
LABEL 1
[NEC 690.13(B) AND NEC 690.15(C) ]
LABEL 2
[NEC 705.12 (B) (3) (3)]
TURN RAPID SHUTDOWN
SWICH TO THE OFF
POSITION TO SHUT DOWN
PV SYSTEM AND REDUCE
SHOCK HAZARD IN ARRAY
LABEL 7
[NEC 690.56 (B), 690.4 (D) AND 705.10]
LABEL 6
AT DIRECT-CURRENT EXPOSED RACEWAYS, CABLE TRAYS, COVERS AND
ENCLOSURES OF JUNCTION BOXES, AND OTHER WIRING METHODS; SPACED
AT MAXIMUM 10FT SECTION OR WHERE SEPARATED BY ENCLOSURES, WALLS,
PARTITIONS, CEILINGS, OR FLOORS.
[NEC 690.31(G)(3&4)]
LABEL 3 TURN RAPID SHUTDOWN
SWITCH TO THE OFF
POSITION TO SHUT DOWN
CONDUCTORS OUTSIDE
THE ARRAY. CONDUCTORS
WITHIN THE ARRAY REMAIN
ENERGIZED IN SUNLIGHT
LABEL 8
FOR PV SYSTEMS THAT ONLY SHUT DOWN CONDUCTORS
LEAVING THE ARRAY:
SIGN TO BE LOCATED ON OR NO MORE THAN 3 FT AWAY
FROM SERVICE DISCONNECTING MEANS TO WHICH THE
PV SYSTEMS ARE CONNECTED AND SHALL INDICATE THE
LOCATION OF ALL IDENTIFIED RAPID SHUTDOWN
SWITCHES IF NOT AT THE SAME LOCATION.
[NEC 690.56 (C) (1) (B)]
LABEL 4
EQUIPMENT CONTAINING OVERCURRENT
DEVICES IN CIRCUITS SUPPLYING POWER TO A
BUSBAR OR CONDUCTOR SUPPLIED FROM
MULTIPLE SOURCES SHALL BE MARKED TO
INDICATE THE PRESENCE OF ALL SOURCES
[NEC 705.10]
MAIN SERVICE PANEL
LABELING DIAGRAM:1
LABEL 5
[NEC 690.54]
3
2
4
EXISTING SUB PANEL
(IF WHERE POINT OF
INTERCONNECTION
IS MADE)
1 2
PV COMBINER
SUBPANEL -
AC DISCONNECT
1 5
IF USED TO COMBINE
PV OUTPUT CIRCUITS
1
3
4
INVERTER (S)
LABEL 9
A RAPID SHUTDOWN SWITCH SHALL HAVE A LABEL
LOCATED ON OR NO MORE THAN 3 FT FROM THE SWITCH
THAT INCLUDES THIS WORDING. THE LABEL SHALL BE
REFLECTIVE, WITH ALL LETTERS CAPITALIZED AND HAVING A
MINIMUM HEIGHT OF 3/8 IN., IN WHITE ON RED
BACKGROUND.
[NEC 690.56 (C)]
AC JUNCTION BOX
OR COMBINER BOX
DC
ELECTRIC SHOCK HAZARD
WARNING
TERMINALS ON BOTH LINE AND
LOAD SIDES MAY BE ENERGIZED IN
THE OPEN POSITION
!
THIS EQUIPMENT IS FED BY MULTIPLE
SOURCES. TOTAL RATING OF ALL
OVERCURRENT DEVICES, EXCLUDING
MAIN SUPPLY OVERCURRENT
DEVICE, SHALL NOT EXCEED
AMPACITY OF BUSBAR.
!
WARNING!
DUAL POWER SUPPLY
WARNING
SOURCES: UTILITY GRID AND PV
SOLAR ELECTRIC SYSTEM
!
8
WARNING: PHOTOVOLTAIC
POWER SOURCE
SOLAR PV SYSTEM EQUIPPED
WITH RAPID SHUTDOWN
SOLAR PV SYSTEM EQUIPPED
WITH RAPID SHUTDOWN
SOLAR ELECTRIC
PV PANELS
SOLAR ELECTRIC
PV PANELS
RAPID SHUTDOWN
SWITCH FOR
SOLAR PV SYSTEM
2
2
2 2
LABEL 10
EACH PV SYSTEM DISCONNECTING MEANS SHALL PLAINLY
INDICATE WHETHER IN THE OPEN (OFF) OR CLOSED (ON)
POSITION AND BE PERMANENTLY MARKED:
“PV SYSTEM DISCONNECT” OR EQUIVALENT.
[NEC 690.13(B), 690.15 AND 705.20]
10
WHERE ALL TERMINALS OF THE DISCONNECTINGS
MEANS MAY BE ENERGIZED IN THE OPEN POSITION, A
WARNING SIGN SHALL BE MOUNTED ON OR ADJACENT
TO THE DISCONNECTING MEANS.
ALL INTERACTIVE SYSTEM(S) POINTS OF
INTERCONNECTION WITH OTHER SOURCES SHALL
BE MARKED AT AN ACCESSIBLE LOCATION AT THE
DISCONNECTING MEANS AS A POWER SOURCE
AND WITH THE RATED AC OUTPUT CURRENT AND
THE NOMINAL OPERATING AC VOLTAGE.
PERMANENT WARNING LABELS SHALL BE APPLIED TO
DISTRIBUTION EQUIPMENT.
A PERMANENT WARNING LABEL SHALL BE
APPLIED TO THE DISTRIBUTION EQUIPMENT
ADJACENT TO THE BACK-FED BREAKER FROM
THE INVERTER.
[NEC 705.12 (B) (3) (2)]
BUILDINGS WITH PV SYSTEMS SHALL HAVE A PERMANENT
LABEL LOCATED AT EACH SERVICE EQUIPMENT LOCATION
TO WHICH THE PV SYSTEMS ARE CONNECTED OR AT AN
APPROVED READILY VISIBLE LOCATION AND SHALL INDICATE
THE LOCATION OF RAPID SHUTDOWN INITIATION DEVICES.
THE LABEL SHALL INCLUDE A SIMPLE DIAGRAM OF A BUILDING
WITH A ROOF AND SHALL INCLUDE THE FOLLOWING WORDS:
THE TITLE “SOLAR PV SYSTEM IS EQUIPPED WITH
RAPID SHUTDOWN” SHALL UTILIZE CAPITALIZED
CHARACTERS WITH A MINIMUM HEIGHT OF 3/8 IN. IN
BLACK ON YELLOW BACKGROUND, AND THE REMAINING
CHARACTERS SHALL BE CAPITALIZED WITH A MINIMUM
HEIGHT OF 3/16 IN. IN BLACK ON WHITE BACKGROUND.
(1) BUILDINGS WITH MORE THAN ONE RAPID SHUTDOWN TYPE. FOR BUILDINGS THAT HAVE PV SYSTEMS
WITH BOTH RAPID SHUTDOWN TYPES OR A PV SYSTEM WITH A RAPID SHUTDOWN TYPE AND A PV SYSTEM
WITH NO RAPID SHUTDOWN, A DETAILED PLAN VIEW DIAGRAM OF THE ROOF SHALL BE PROVIDED SHOWING
EACH DIFFERENT PV SYSTEM AND A DOTTED LINE AROUND AREAS THAT REMAIN ENERGIZED AFTER THE RAPID
SHUTDOWN SWITCH IS OPERATED.
INVERTER OUTPUT CONNECTION
DO NOT RELOCATE THIS OVER
CURRENT DEVICE
MAIN PHOTOVOLTAIC
SERVICE DISCONNECT
PHOTOVOLTAIC
AC DISCONNECT
WARNING
SITE INFORMATION
LINDSEY SCHROMEN-WAWRIN
306 W 3RD ST
PORT ANGELES, WA 98362
DC System Size: 6.40 kW DC
Lat, 48.11890
Long, -123.43968
(16) VSUN 400-108BMH (400W)
PV Modules
Inverter(s)
UTILITY: CITY OF PORT ANGELES
DRAWN BY: M. BOBO
DATE:
6/14/2023
9981 West 190th St
Unit K Mokena IL 60448
T: 708-995-1643
Revolution Energy Systems Inc.
(4) HOYMILES HM-1200N (240V)
(2) HOYMILES HM-300N (240V)
AC System Size: 5.40 kW AC / 5.40 kVA
AHJ: CITY OF PORT ANGELES
LABELS - PV07
22.50 A
AC
M
MS
P
LC
JB
PV
SITE INFORMATION
LINDSEY SCHROMEN-WAWRIN
306 W 3RD ST
PORT ANGELES, WA 98362
DC System Size: 6.40 kW DC
Lat, 48.11890
Long, -123.43968
(16) VSUN 400-108BMH (400W)
PV Modules
Inverter(s)
UTILITY: CITY OF PORT ANGELES
DRAWN BY: M. BOBO
DATE:
6/14/2023
9981 West 190th St
Unit K Mokena IL 60448
T: 708-995-1643
Revolution Energy Systems Inc.
(4) HOYMILES HM-1200N (240V)
(2) HOYMILES HM-300N (240V)
AC System Size: 5.40 kW AC / 5.40 kVA
AHJ: CITY OF PORT ANGELES
PLACARD - PV08
CAUTION
POWER TO THIS BUILDING IS ALSO SUPPLIED FROM ROOF MOUNTED SOLAR
ARRAYS WITH SAFETY DISCONNECTS AS SHOWN:
306 W 3RD ST, PORT ANGELES, WA 98362
DIRECTORY
PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF THE
SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM.
(ALL PLAQUES AND SIGNAGE WILL BE INSTALLED AS OUTLINED WITHIN:
NEC 690.56(B)&(C), [NEC 705.10])
MAIN DISTRIBUTION
UTILITY DISCONNECT
PV METER
LOAD CENTER
UTILITY METER
PV ARRAY
AC DISCONNECT
(PLACARD SHOULD BE RED WITH WHITE LETTERING)
SITE INFORMATION
LINDSEY SCHROMEN-WAWRIN
306 W 3RD ST
PORT ANGELES, WA 98362
DC System Size: 6.40 kW DC
Lat, 48.11890
Long, -123.43968
(16) VSUN 400-108BMH (400W)
PV Modules
Inverter(s)
UTILITY: CITY OF PORT ANGELES
DRAWN BY: M. BOBO
DATE:
6/14/2023
9981 West 190th St
Unit K Mokena IL 60448
T: 708-995-1643
Revolution Energy Systems Inc.
(4) HOYMILES HM-1200N (240V)
(2) HOYMILES HM-300N (240V)
AC System Size: 5.40 kW AC / 5.40 kVA
AHJ: CITY OF PORT ANGELES
SITE PHOTOS - PV09
SITE PHOTOS:
AERIAL VIEW:MAP VIEW:
GENERAL NOTES
1. INSTALLATION OF SOLAR PHOTOVOLTAIC SYSTEM SHALL BE IN ACCORDANCE WITH NEC ARTICLE
690, AND ALL OTHER APPLICABLE NEC CODES WHERE NOTED OR EXISTING
2. PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL
EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110
3. ALL WIRES, INCLUDING THE GROUNDING ELECTRODE CONDUCTOR SHALL BE PROTECTED FROM
PHYSICAL DAMAGE IN ACCORDANCE WITH NEC ARTICLE 250
4. THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE; THIS SYSTEM SHALL COMPLY WITH IEEE 1547
ANTI-ISLANDING GRID PROFILE,NOT UTILITY INTERACTIVE PROFILE OF UL 1741 (CA RULE 21)
5. ALL DC WIRES SHALL BE SIZED ACCORDING TO [NEC 690.8]
6. DC CONDUCTORS SHALL BE WITHIN PROTECTED RACEWAYS IN ACCORDANCE WITH [NEC 690.31]
7. ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL JURISDICTIONAL BUILDING CODE
PHOTOVOLTAIC (PV) SYSTEM SPECIFICATIONS
APPLICABLE GOVERNING CODES
SITE SPECIFICATIONS
OCCUPANCY: R-3
ZONING: RESIDENTIAL
COVER PAGE - PV01
SITE INFORMATION
LINDSEY SCHROMEN-WAWRIN
306 W 3RD ST
PORT ANGELES, WA 98362
DC System Size: 6.46 kW DC
Lat, 48.11890
Long, -123.43968
(17) SOLAR4 AMERICA S4AI-120B-380C (380W)
PV Modules
Inverter(s)
UTILITY: CITY OF PORT ANGELES
DRAWN BY: M. BOBO
DATE:
10/9/2023
9981 West 190th St
Unit K Mokena IL 60448
T: 708-995-1643
Revolution Energy Systems Inc.
(4) HOYMILES HM-1200N (240V)
(1) HOYMILES HM-600N (240V)
AC System Size: 5.70 kW AC / 5.70 kVA
AHJ: CITY OF PORT ANGELES
(1) HOYMILES HM-300N (240V)
"AS-BUILT"
2020 NEC
2018 IRC
2018 IMC
2018 IFGC
EQUIPMENT:
AC System Size: 5.70 kW AC / 5.70 kVA
DC SYSTEM SIZE: 6.46 kW DC
(17) SOLAR4 AMERICA S4AI-120B-380C (380W) PV Modules
(4) HOYMILES HM-1200N (240V) Inverters
(1) HOYMILES HM-600N (240V) Inverters
(1) HOYMILES HM-300N (240V) Inverters
RACKING: S-5-N 1.5 CLAMP - 48" O.C.
SHEET INDEX:
PV01 COVER PAGE
PV02 SITE PLAN
PV03 ROOF ATTACHMENTS
PV04 MOUNTING DETAIL
PV05 LINE DIAGRAM
PV06 ELECTRICAL CALCS
PV07 LABELS
PV08 PLACARD
PV09 SITE PHOTOS
DESIGN CRITERIA
SNOW LOAD: 25 PSF
WIND SPEED: 110 MPH
AND DOES NOT INCLUDE STORAGE BATTERIES OR OTHER ALTERNATIVE STORAGE SOURCES
M
MS
P
LC
JB
AC
M
MS
P
LC
JB
AC
SITE INFORMATION
LINDSEY SCHROMEN-WAWRIN
306 W 3RD ST
PORT ANGELES, WA 98362
DC System Size: 6.46 kW DC
Lat, 48.11890
Long, -123.43968
(17) SOLAR4 AMERICA S4AI-120B-380C (380W)
PV Modules
Inverter(s)
UTILITY: CITY OF PORT ANGELES
DRAWN BY: M. BOBO
DATE:
10/9/2023
9981 West 190th St
Unit K Mokena IL 60448
T: 708-995-1643
Revolution Energy Systems Inc.
(4) HOYMILES HM-1200N (240V)
(1) HOYMILES HM-600N (240V)
AC System Size: 5.70 kW AC / 5.70 kVA
AHJ: CITY OF PORT ANGELES
(1) HOYMILES HM-300N (240V)
"AS-BUILT"
SITE PLAN - PV02
MOUNTING PLANE:
MP1
ARRAY DETAILS:
AZIMUTH:
212°
TILT:
30°
MP2 32°30°
VISIBLE, LOCKABLE,
LABELED AC DISCONNECT
LOCATED WITHIN 10'
OF UTILITY METER
CLOSE UP OF HOUSE
MSP
M UTILITY METER
PV
AC VISIBLE, LOCKABLE, LABELED
AC DISCONNECT
METER SOCKET
(For utility PV meter)
INV
C
INVERTER
EQUIPMENT LEGEND:
SUB PANEL
COMBINER BOX LC BATT
MSD
JB
PV MODULES
PROPERTY LINE
SUB
LOAD CENTER BATTERY(IES)JUNCTION BOXMAIN SERVICE
PANEL
MAIN SERVICE
DISCONNECT SS SMART SWITCH
(IQ System Controller)
FIRE ACCESS
PATHWAY (3' TYP)
ATS AUTOMATIC
TRANSFER SWITCH
D
R
I
V
E
W
A
Y
P
R
O
P
E
R
T
Y
L
I
N
E
~
4
0
'
-
1
'
'
W
3
R
D
S
T
P
R
O
P
E
R
T
Y
L
I
N
E
~
4
0
'
-
1
'
'PROPERTY LINE ~133'-7''PROPERTY LINE ~133'-9''MP1
MP2
90'-4"
7'-3"
2'-6"
1'-10"
M
M
S
P
LC
JB
AC
SITE INFORMATION
LINDSEY SCHROMEN-WAWRIN
306 W 3RD ST
PORT ANGELES, WA 98362
DC System Size: 6.46 kW DC
Lat, 48.11890
Long, -123.43968
(17) SOLAR4 AMERICA S4AI-120B-380C (380W)
PV Modules
Inverter(s)
UTILITY: CITY OF PORT ANGELES
DRAWN BY: M. BOBO
DATE:
10/9/2023
9981 West 190th St
Unit K Mokena IL 60448
T: 708-995-1643
Revolution Energy Systems Inc.
(4) HOYMILES HM-1200N (240V)
(1) HOYMILES HM-600N (240V)
AC System Size: 5.70 kW AC / 5.70 kVA
AHJ: CITY OF PORT ANGELES
(1) HOYMILES HM-300N (240V)
"AS-BUILT"
ROOF ATTACHMENTS - PV03
PV MODULE COUNT:
ARRAY AREA:
ROOF AREA:
17
PERCENT OF ROOF COVERED:
ARRAY WEIGHT:
POINT LOAD:
DISTRIBUTED LOAD: (lbs/ft²)
1237.24 ft²
27%
MODULE COUNT * 19.66 ft² = 334.22
MODULE COUNT * 42.99 lbs = 730.83 lbs
ARRAY LBS/ATTACHMENTS = 18.74
(ARRAY) WEIGHT/AREA = 2.2 lbs/ft²
PHOTOVOLTAIC ARRAY STRUCTURAL CRITERIA:
HOUSE ELEVATION
EQUIPMENT INFORMATION:
RAIL MANUFACTURER:
RAIL PART NUMBER:
ATTACHMENTS
ATTACHMENT QTY:
SPLICE QTY:
MIDCLAMP QTY:
ENDCLAMP QTY:
CHIKO
7-RB
S-5-N 1.5 CLAMP
39
9
36
25
ROOF TYPE:
ROOF FRAMING:
RAFTER/TOP CHORD SIZE:
RAFTER/TOP CHORD SPACING:
ATTACHMENT SPACING:
ROOF INFORMATION
METAL ROOF
MANUFACTURED TRUSS
2" X 4"
24"
48"
34'-11"
36'-1"
18" TYP
3' TYP
11'-9"
15'-9"
±12'-11"
±15'-11"
35'-9"
H O Y M I L E S M I C R O I N V E R T E R L E G E N D S :
HM-1200N ( 4 panels per 1 microinverter)
HM-600N ( 2 panels per 1 microinverter)
HM-300N (1 panel per 1 microinverter)
1-3
1-3
2-1
1-1
1-1
1-2
1-3
1-1
1-1
1-2
2-2
2-2
2-2
2-2
2-3
2-3
2-3
SITE INFORMATION
LINDSEY SCHROMEN-WAWRIN
306 W 3RD ST
PORT ANGELES, WA 98362
DC System Size: 6.46 kW DC
Lat, 48.11890
Long, -123.43968
(17) SOLAR4 AMERICA S4AI-120B-380C (380W)
PV Modules
Inverter(s)
UTILITY: CITY OF PORT ANGELES
DRAWN BY: M. BOBO
DATE:
10/9/2023
9981 West 190th St
Unit K Mokena IL 60448
T: 708-995-1643
Revolution Energy Systems Inc.
(4) HOYMILES HM-1200N (240V)
(1) HOYMILES HM-600N (240V)
AC System Size: 5.70 kW AC / 5.70 kVA
AHJ: CITY OF PORT ANGELES
(1) HOYMILES HM-300N (240V)
"AS-BUILT"
MOUNTING DETAIL - PV04
EQUIPMENT INFORMATION:
RAIL MANUFACTURER:
RAIL PART NUMBER:
ATTACHMENTS
ATTACHMENT QTY:
SPLICE QTY:
MIDCLAMP QTY:
ENDCLAMP QTY:
CHIKO
7-RB
S-5-N 1.5 CLAMP
39
9
36
25
ROOF TYPE:
ROOF FRAMING:
RAFTER/TOP CHORD SIZE:
RAFTER/TOP CHORD SPACING:
ATTACHMENT SPACING:
ROOF INFORMATION
METAL ROOF
MANUFACTURED TRUSS
2" X 4"
24"
48"
PV MODULE COUNT:
ARRAY AREA:
ROOF AREA:
17
PERCENT OF ROOF COVERED:
ARRAY WEIGHT:
POINT LOAD:
DISTRIBUTED LOAD: (lbs/ft²)
1237.24 ft²
27%
MODULE COUNT * 19.66 ft² = 334.22
MODULE COUNT * 42.99 lbs = 730.83 lbs
ARRAY LBS/ATTACHMENTS = 18.74
(ARRAY) WEIGHT/AREA = 2.2 lbs/ft²
PHOTOVOLTAIC ARRAY STRUCTURAL CRITERIA:
CHIKO
END CLAMP
CHIKO
MID CLAMP
1 2
PV MODULE
RAIL
PV MODULE
RAIL
PV MODULE
1'-8"
MAX.
RAIL FRONT VIEW
1 END CLAMP DETAILS 2 MID CLAMP DETAILS
RAIL
S-5 MINI/S BRACKET
10" MIN -
1'-4"
MAX
2'-8" MIN -
3'-10" MAX
(E) RAFTER/TOP CHORD
2'-8" MIN -
3'-10" MAX
3
10" MIN -
1'-4"
MAX
(E) RAFTER/TOP CHORDS
48" MAX SPAN
SIDE VIEW
3
DETAIL, MOUNTING
SITE INFORMATION
LINDSEY SCHROMEN-WAWRIN
306 W 3RD ST
PORT ANGELES, WA 98362
DC System Size: 6.46 kW DC
Lat, 48.11890
Long, -123.43968
(17) SOLAR4 AMERICA S4AI-120B-380C (380W)
PV Modules
Inverter(s)
UTILITY: CITY OF PORT ANGELES
DRAWN BY: M. BOBO
DATE:
10/9/2023
9981 West 190th St
Unit K Mokena IL 60448
T: 708-995-1643
Revolution Energy Systems Inc.
(4) HOYMILES HM-1200N (240V)
(1) HOYMILES HM-600N (240V)
AC System Size: 5.70 kW AC / 5.70 kVA
AHJ: CITY OF PORT ANGELES
(1) HOYMILES HM-300N (240V)
"AS-BUILT"
LINE DIAGRAM - PV05
TYPE:
MODULES:
INVERTERS:
AC DISCONNECTS:
QTY:
(17)
(1)
DESCRIPTION:
SOLAR4 AMERICA S4AI-120B-380C 380
PV AC Disconnect, 240V, 2-Pole, With 30A Fuses
RATING:
380 W
60 A
Equipment Schedule
1
(2)
(1)BARE CU - (GROUND)N/A - FREE AIR
2
(2)
(1)10 AWG (90°C)
THHN/THWN-2, COPPER - (L1, L2)
THWN-2 COPPER - (GROUND)
3/4" EMT
TAG QTY WIRE GAUGE
Conduit & Conductor Schedule
DESCRIPTION CONDUIT SIZE
SOLAR4 AMERICA S4AI-120B-380C 380 Specs
POWER MAX (PMAX):
OPEN CIRCUIT VOLTAGE (VOC):
MAX POWER-POINT CURRENT (IMP):
MAX POWER-POINT VOLTAGE (VMP):
SHORT CIRCUIT CURRENT (ISC):
SERIES FUSE RATING:
380W
20A
HOYMILES HM-1200N (240V)1200 W(4)
HOYMILES : HM-1200N (240V) Specs
MAX INPUT VOLTAGE:
MAX INPUT CURRENT:
NOMINAL DC INPUT VOLTAGE:
MAXIMUM OUTPUT POWER:
NOM. OUTPUT VOLTAGE:
MAX OUTPUT CURRENT:
1-Phase, 60 HZ, UL 1741 Listed
60 V
20 A
60 V
1200 W
240 V
5.00 A
AC-CABLE , COPPER (L1, L2)
4
LOAD CENTER:(1)PV LOAD CENTER, NEMA 3R RATED
VISIBLE, LOCKABLE,
LABELED AC DISCONNECT
LOCATED WITHIN 10'
OF UTILITY METER
125 A
10 AWG (90°C)
12 AWG (90°C)
J-BOX
3
GND
2P - 20A
(N) 125A PV LOAD CENTER,
NEMA 3R RATED
J-BOX
4 MODULES
1-HM1200N
=
STRING (1): 20.0A (9 MODULES)
2 MODULES
1-HM600N
=
1 2
J-BOX
=
STRING (2): 20.0A (8 MODULES)
=
1 2
1 MODULE
1-HM300N
4 MODULES
1-HM1200N
690.12 RAPID
SHUTDOWN COMPLIANT
2P - 20A
=
3 MODULES
1-HM1200N
INVERTERS:HOYMILES HM-600N (240V)600 W(1)
HOYMILES : HM-300N (240V) Specs
MAX INPUT VOLTAGE:
MAX INPUT CURRENT:
NOMINAL DC INPUT VOLTAGE:
MAXIMUM OUTPUT POWER:
NOM. OUTPUT VOLTAGE:
MAX OUTPUT CURRENT:
1-Phase, 60 HZ, UL 1741 Listed
60 V
20 A
60 V
300 W
240 V
1.25 A
12 AWG (90°C)
6 AWG (75°C)
6 AWG (75°C)
THHN/THWN-2, COPPER - (L1, L2, NEUTRAL)
THWN-2 COPPER - (GROUND)5
(3)
(1)
10 AWG (90°C)
10 AWG (90°C)
THHN/THWN-2, COPPER - (L1, L2)
THWN-2 COPPER - (GROUND)
3/4" PVC4(1)
(2)
10 AWG (90°C)
10 AWG (90°C)
THHN/THWN-2, COPPER - (L1, L2)
THWN-2 COPPER - (GROUND)
3/4" EMT3
(4)
(1)
3/4" PVC
5
AC DISCONNECTS:(1)PV AC Disconnect, 240V, 2-Pole 200 A
HOYMILES : HM-600N (240V) Specs
MAX INPUT VOLTAGE:
MAX INPUT CURRENT:
NOMINAL DC INPUT VOLTAGE:
MAXIMUM OUTPUT POWER:
NOM. OUTPUT VOLTAGE:
MAX OUTPUT CURRENT:
1-Phase, 60 HZ, UL 1741 Listed
60 V
20 A
60 V
600 W
240 V
2.5 A
41.7V
10.99A
34.6V
11.98A INVERTERS:HOYMILES HM-300N (240V)300 W(1)
EXCESS PORT WILL BE CAPPED
=
3 MODULES
1-HM1200N
EXCESS PORT WILL BE CAPPED
LINE SIDE TAP
USING INSULATION
PEIRCING 705.12(A)
(E)
G
(E) UTILITY METER
(E) GROUNDING
ELECTRODE
N
(E) LOADS
(E) 200A MAIN SERVICE PANEL
(E) 200A-2P
120/240 VAC
TO UTILITY GRID
(E) LOADS
CONNECTION AS A LINE/SUPPLY
SIDE CONNECTION - NEC
705.12(A)
METER #: 12571
PV AC DISCONNECT
60A VISIBLE, LOCKABLE,
LABELED, OPEN
240V, 2-POLE
WITH 30A FUSES
N
G
(N) METER BASE
(N) WEATHER HEAD
ELECTRICAL CALCS - PV06
SYSTEM OCPD CALCULATIONS
INVERTER MODEL(S):
# OF INVERTER(S):
(# OF INVERTERS) X (MAX OUTPUT CURRENT):
(# OF INVERTERS) X (MAX OUTPUT CURRENT) X 125% <= OCPD RATING
SITE INFORMATION
LINDSEY SCHROMEN-WAWRIN
306 W 3RD ST
PORT ANGELES, WA 98362
DC System Size: 6.46 kW DC
Lat, 48.11890
Long, -123.43968
(17) SOLAR4 AMERICA S4AI-120B-380C (380W)
PV Modules
Inverter(s)
UTILITY: CITY OF PORT ANGELES
DRAWN BY: M. BOBO
DATE:
10/9/2023
9981 West 190th St
Unit K Mokena IL 60448
T: 708-995-1643
Revolution Energy Systems Inc.
(4) HOYMILES HM-1200N (240V)
(1) HOYMILES HM-600N (240V)
AC System Size: 5.70 kW AC / 5.70 kVA
AHJ: CITY OF PORT ANGELES
(1) HOYMILES HM-300N (240V)
"AS-BUILT"
4
5.00A
HOYMILES HM-1200N (240V)
(23.75A X 1.25) = 29.68A <= 30A, OK
STRING CALCULATIONS
HOYMILES : HM-1200N,HM-600N, HM-300N
MAX AC CURRENT
MICRO INVERTER(S) IN SERIES:
NOMINAL VOLTAGE / RANGE²:
MAX AC OUTPUT POWER:
ARRAY DC POWER:
TOTAL MAX AC CURRENT:
6460W
23.75A
STRING #1
(2) HM-1200N ; (1) HM-600N
3000W
STRING #2
211V - 264V
TAG QTY DESCRIPTION CONDUIT SIZE CONDUCTOR RATING
Conduit & Conductor Schedule
CONDUCTOR TEMP. RATE AMBIENT TEMP # OF CONDUCTORS
DERATE
CONDUCTOR RATING
W/DERATES CONDUIT FILLTEMP. DERATEWIRE GAUGE
10 AWG
10 AWG
3/4" EMT 40A 90°C 11.45%
THHN/THWN-2, COPPER - (L1, L2)
THWN-2 COPPER - (GROUND)25°C 1.0(1)
(2)
1 (1)
(2)12 AWG
BARE CU - (GROUND)N/A - FREE AIR 30A 90°C 25°C 1.04 N/A - FREE AIR 31.2A N/A - FREE AIR
2
10 AWG
10 AWG
3/4" EMT 40A 90°C
THHN/THWN-2, COPPER - (L1, L2)
THWN-2 COPPER - (GROUND)3 25°C 0.8
(4)
(1)
41.6A
AC-CABLE , COPPER (L1, L2)
15.62A
NUMBER OF CURRENT CARRYING CONDUCTORS
4-6
7-9
10-20
PERCENT OF VALUES
.80
.70
.50
GROUNDING & GENERAL NOTES:
1. PV INVERTER IS UNGROUNDED, TRANSFORMER-LESS TYPE.
2. DC GEC AND AC EGC TO BE SPLICED TO EXISTING ELECTRODE
3. ANY EXISTING WIRING INVOLVED WITH PV SYSTEM CONNECTION THAT IS FOUND TO
BE INADEQUATE PER CODE SHALL BE CORRECTED PRIOR TO FINAL INSPECTION.
4. JUNCTION BOX QUANTITIES, AND PLACEMENT SUBJECT TO CHANGE IN THE FIELD -
JUNCTION BOXES DEPICTED ON ELECTRICAL DIAGRAM REPRESENT WIRE TYPE
TRANSITIONS.
5. AC DISCONNECT NOTED IN EQUIPMENT SCHEDULE OPTIONAL IF OTHER
AC DISCONNECTING MEANS IS LOCATED WITHIN 10' OF SERVICE DISCONNECT.
INTERCONNECTION NOTES:
1. INTERCONNECTION SIZING, LIMITATIONS AND COMPLIANCE DETERMINED IN ACCORDANCE WITH [NEC
705.12], AND [NEC 690.64].
2. GROUND FAULT PROTECTION IN ACCORDANCE WITH [NEC 215.9], [NEC 230.95] AND [NEC 690.5]
3. ALL EQUIPMENT TO BE RATED FOR BACKFEEDING.
4. PV BREAKER TO BE POSITIONED AT THE OPPOSITE END OF THE BUSBAR RELATIVE TO THE MAIN BREAKER.
DISCONNECT NOTES
1. DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS OPENED THE CONDUCTORS
REMAINING LIVE ARE CONNECTED TO THE TERMINALS MARKED “LINE SIDE” (TYPICALLY THE UPPER TERMINALS)
2. AC DISCONNECT MUST BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BE LOCKABLE, AND BE A
VISIBLE-BREAK SWITCH
MAX OUTPUT CURRENT:
1
2.5A
HOYMILES HM-600N (240V)
20.00A 2.5A
(2) HM-1200N ; (1) HM-300N
2700W
211V - 264V
14.06A
12 AWG
90°C10 AWG
10 AWG
40A
THHN/THWN-2, COPPER - (L1, L2)
THWN-2 COPPER - (GROUND)4
(2)
(1)
25°C 1.03/4" PVC
1.04
1.04
1.04
33.28A
41.6A
19.09%
12.03%
1
1.25A
HOYMILES HM-300N (240V)
1.25A
PV LOAD CALCULATIONS: SUPPLY SIDE TIE-IN
FEEDER WIRE RATING:
(FEEDER RATING ÷ 1.25)
200A
160.0000A (FEEDER WIRES ALLOWABLE SOLAR)
160.0000A (AVAILABLE FOR PV)
ALLOWABLE SOLAR CALCULATION
75°C 1.05
THHN/THWN-2, COPPER - (L1, L2, NEUTRAL)
THWN-2 COPPER - (GROUND)5
(3)
(1)25°C 1.0 38.37%6 AWG
6 AWG
65A 68.25A3/4" PVC
RATED AC OUTPUT CURRENT:
NOMINAL OPERATING AC VOLTAGE:
PHOTOVOLTAIC AC DISCONNECT
240 V
7
LABELING NOTES:
1. LABELS CALLED OUT ACCORDING TO ALL COMMON CONFIGURATIONS. ELECTRICIAN TO DETERMINE EXACT
REQUIREMENTS IN THE FIELD PER CURRENT NEC AND LOCAL CODES AND MAKE APPROPRIATE ADJUSTMENTS.
2. LABELING REQUIREMENTS BASED ON THE 2020 NATIONAL ELECTRIC CODE, OSHA STANDARD 19010.145, ANSI
Z535.
3. MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION.
4. LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED [NEC 110.21(B)(3)]
5. LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8", WHITE ON RED BACKGROUND; REFLECTIVE, AND
PERMANENTLY AFFIXED [IFC 605.11.1.1]
5
(ONLY IF PV
INTERCONNECTION
CONSISTS OF LOAD
SIDE BREAKER)
3
5
(ONLY IF PV
INTERCONNECTION
CONSISTS OF LOAD
SIDE BREAKER)
9 1
6
INTEGRATED DC DISCONNECT
*ELECTRICAL DIAGRAM SHOWN ABOVE IS FOR LABELING PURPOSES ONLY. NOT AN ACTUAL REPRESENATION OF EQUIPMENT AND CONNECTIONS TO BE INSTALLED. LABEL LOCATIONS
PRESENTED MAY VERY DEPENDING ON TYPE OF INTERCONNECTION METHOD AND LOCATION PRESENTED ON THE ELECTRICAL DIAGRAM PAGE.
6
4
LABEL 1
[NEC 690.13(B) AND NEC 690.15(C) ]
LABEL 2
[NEC 705.12 (B) (3) (3)]
TURN RAPID SHUTDOWN
SWICH TO THE OFF
POSITION TO SHUT DOWN
PV SYSTEM AND REDUCE
SHOCK HAZARD IN ARRAY
LABEL 7
[NEC 690.56 (B), 690.4 (D) AND 705.10]
LABEL 6
AT DIRECT-CURRENT EXPOSED RACEWAYS, CABLE TRAYS, COVERS AND
ENCLOSURES OF JUNCTION BOXES, AND OTHER WIRING METHODS; SPACED
AT MAXIMUM 10FT SECTION OR WHERE SEPARATED BY ENCLOSURES, WALLS,
PARTITIONS, CEILINGS, OR FLOORS.
[NEC 690.31(G)(3&4)]
LABEL 3 TURN RAPID SHUTDOWN
SWITCH TO THE OFF
POSITION TO SHUT DOWN
CONDUCTORS OUTSIDE
THE ARRAY. CONDUCTORS
WITHIN THE ARRAY REMAIN
ENERGIZED IN SUNLIGHT
LABEL 8
FOR PV SYSTEMS THAT ONLY SHUT DOWN CONDUCTORS
LEAVING THE ARRAY:
SIGN TO BE LOCATED ON OR NO MORE THAN 3 FT AWAY
FROM SERVICE DISCONNECTING MEANS TO WHICH THE
PV SYSTEMS ARE CONNECTED AND SHALL INDICATE THE
LOCATION OF ALL IDENTIFIED RAPID SHUTDOWN
SWITCHES IF NOT AT THE SAME LOCATION.
[NEC 690.56 (C) (1) (B)]
LABEL 4
EQUIPMENT CONTAINING OVERCURRENT
DEVICES IN CIRCUITS SUPPLYING POWER TO A
BUSBAR OR CONDUCTOR SUPPLIED FROM
MULTIPLE SOURCES SHALL BE MARKED TO
INDICATE THE PRESENCE OF ALL SOURCES
[NEC 705.10]
MAIN SERVICE PANEL
LABELING DIAGRAM:1
LABEL 5
[NEC 690.54]
3
2
4
EXISTING SUB PANEL
(IF WHERE POINT OF
INTERCONNECTION
IS MADE)
1 2
PV COMBINER
SUBPANEL -
AC DISCONNECT
1 5
IF USED TO COMBINE
PV OUTPUT CIRCUITS
1
3
4
INVERTER (S)
LABEL 9
A RAPID SHUTDOWN SWITCH SHALL HAVE A LABEL
LOCATED ON OR NO MORE THAN 3 FT FROM THE SWITCH
THAT INCLUDES THIS WORDING. THE LABEL SHALL BE
REFLECTIVE, WITH ALL LETTERS CAPITALIZED AND HAVING A
MINIMUM HEIGHT OF 3/8 IN., IN WHITE ON RED
BACKGROUND.
[NEC 690.56 (C)]
AC JUNCTION BOX
OR COMBINER BOX
DC
ELECTRIC SHOCK HAZARD
WARNING
TERMINALS ON BOTH LINE AND
LOAD SIDES MAY BE ENERGIZED IN
THE OPEN POSITION
!
THIS EQUIPMENT IS FED BY MULTIPLE
SOURCES. TOTAL RATING OF ALL
OVERCURRENT DEVICES, EXCLUDING
MAIN SUPPLY OVERCURRENT
DEVICE, SHALL NOT EXCEED
AMPACITY OF BUSBAR.
!
WARNING!
DUAL POWER SUPPLY
WARNING
SOURCES: UTILITY GRID AND PV
SOLAR ELECTRIC SYSTEM
!
8
WARNING: PHOTOVOLTAIC
POWER SOURCE
SOLAR PV SYSTEM EQUIPPED
WITH RAPID SHUTDOWN
SOLAR PV SYSTEM EQUIPPED
WITH RAPID SHUTDOWN
SOLAR ELECTRIC
PV PANELS
SOLAR ELECTRIC
PV PANELS
RAPID SHUTDOWN
SWITCH FOR
SOLAR PV SYSTEM
2
2
2 2
LABEL 10
EACH PV SYSTEM DISCONNECTING MEANS SHALL PLAINLY
INDICATE WHETHER IN THE OPEN (OFF) OR CLOSED (ON)
POSITION AND BE PERMANENTLY MARKED:
“PV SYSTEM DISCONNECT” OR EQUIVALENT.
[NEC 690.13(B), 690.15 AND 705.20]
10
WHERE ALL TERMINALS OF THE DISCONNECTINGS
MEANS MAY BE ENERGIZED IN THE OPEN POSITION, A
WARNING SIGN SHALL BE MOUNTED ON OR ADJACENT
TO THE DISCONNECTING MEANS.
ALL INTERACTIVE SYSTEM(S) POINTS OF
INTERCONNECTION WITH OTHER SOURCES SHALL
BE MARKED AT AN ACCESSIBLE LOCATION AT THE
DISCONNECTING MEANS AS A POWER SOURCE
AND WITH THE RATED AC OUTPUT CURRENT AND
THE NOMINAL OPERATING AC VOLTAGE.
PERMANENT WARNING LABELS SHALL BE APPLIED TO
DISTRIBUTION EQUIPMENT.
A PERMANENT WARNING LABEL SHALL BE
APPLIED TO THE DISTRIBUTION EQUIPMENT
ADJACENT TO THE BACK-FED BREAKER FROM
THE INVERTER.
[NEC 705.12 (B) (3) (2)]
BUILDINGS WITH PV SYSTEMS SHALL HAVE A PERMANENT
LABEL LOCATED AT EACH SERVICE EQUIPMENT LOCATION
TO WHICH THE PV SYSTEMS ARE CONNECTED OR AT AN
APPROVED READILY VISIBLE LOCATION AND SHALL INDICATE
THE LOCATION OF RAPID SHUTDOWN INITIATION DEVICES.
THE LABEL SHALL INCLUDE A SIMPLE DIAGRAM OF A BUILDING
WITH A ROOF AND SHALL INCLUDE THE FOLLOWING WORDS:
THE TITLE “SOLAR PV SYSTEM IS EQUIPPED WITH
RAPID SHUTDOWN” SHALL UTILIZE CAPITALIZED
CHARACTERS WITH A MINIMUM HEIGHT OF 3/8 IN. IN
BLACK ON YELLOW BACKGROUND, AND THE REMAINING
CHARACTERS SHALL BE CAPITALIZED WITH A MINIMUM
HEIGHT OF 3/16 IN. IN BLACK ON WHITE BACKGROUND.
(1) BUILDINGS WITH MORE THAN ONE RAPID SHUTDOWN TYPE. FOR BUILDINGS THAT HAVE PV SYSTEMS
WITH BOTH RAPID SHUTDOWN TYPES OR A PV SYSTEM WITH A RAPID SHUTDOWN TYPE AND A PV SYSTEM
WITH NO RAPID SHUTDOWN, A DETAILED PLAN VIEW DIAGRAM OF THE ROOF SHALL BE PROVIDED SHOWING
EACH DIFFERENT PV SYSTEM AND A DOTTED LINE AROUND AREAS THAT REMAIN ENERGIZED AFTER THE RAPID
SHUTDOWN SWITCH IS OPERATED.
INVERTER OUTPUT CONNECTION
DO NOT RELOCATE THIS OVER
CURRENT DEVICE
MAIN PHOTOVOLTAIC
SERVICE DISCONNECT
PHOTOVOLTAIC
AC DISCONNECT
WARNING
SITE INFORMATION
LINDSEY SCHROMEN-WAWRIN
306 W 3RD ST
PORT ANGELES, WA 98362
DC System Size: 6.46 kW DC
Lat, 48.11890
Long, -123.43968
(17) SOLAR4 AMERICA S4AI-120B-380C (380W)
PV Modules
Inverter(s)
UTILITY: CITY OF PORT ANGELES
DRAWN BY: M. BOBO
DATE:
10/9/2023
9981 West 190th St
Unit K Mokena IL 60448
T: 708-995-1643
Revolution Energy Systems Inc.
(4) HOYMILES HM-1200N (240V)
(1) HOYMILES HM-600N (240V)
AC System Size: 5.70 kW AC / 5.70 kVA
AHJ: CITY OF PORT ANGELES
(1) HOYMILES HM-300N (240V)
"AS-BUILT"
LABELS - PV07
23.75 A
M
MS
P
LC
JB
AC
SITE INFORMATION
LINDSEY SCHROMEN-WAWRIN
306 W 3RD ST
PORT ANGELES, WA 98362
DC System Size: 6.46 kW DC
Lat, 48.11890
Long, -123.43968
(17) SOLAR4 AMERICA S4AI-120B-380C (380W)
PV Modules
Inverter(s)
UTILITY: CITY OF PORT ANGELES
DRAWN BY: M. BOBO
DATE:
10/9/2023
9981 West 190th St
Unit K Mokena IL 60448
T: 708-995-1643
Revolution Energy Systems Inc.
(4) HOYMILES HM-1200N (240V)
(1) HOYMILES HM-600N (240V)
AC System Size: 5.70 kW AC / 5.70 kVA
AHJ: CITY OF PORT ANGELES
(1) HOYMILES HM-300N (240V)
"AS-BUILT"
PLACARD - PV08
CAUTION
POWER TO THIS BUILDING IS ALSO SUPPLIED FROM ROOF MOUNTED SOLAR
ARRAYS WITH SAFETY DISCONNECTS AS SHOWN:
306 W 3RD ST, PORT ANGELES, WA 98362
DIRECTORY
PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF THE
SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM.
(ALL PLAQUES AND SIGNAGE WILL BE INSTALLED AS OUTLINED WITHIN:
NEC 690.56(B)&(C), [NEC 705.10])
MAIN DISTRIBUTION
UTILITY DISCONNECT
LOAD CENTER
UTILITY METER
PV ARRAY
(PLACARD SHOULD BE RED WITH WHITE LETTERING)
AC DISCONNECT
SITE INFORMATION
LINDSEY SCHROMEN-WAWRIN
306 W 3RD ST
PORT ANGELES, WA 98362
DC System Size: 6.46 kW DC
Lat, 48.11890
Long, -123.43968
(17) SOLAR4 AMERICA S4AI-120B-380C (380W)
PV Modules
Inverter(s)
UTILITY: CITY OF PORT ANGELES
DRAWN BY: M. BOBO
DATE:
10/9/2023
9981 West 190th St
Unit K Mokena IL 60448
T: 708-995-1643
Revolution Energy Systems Inc.
(4) HOYMILES HM-1200N (240V)
(1) HOYMILES HM-600N (240V)
AC System Size: 5.70 kW AC / 5.70 kVA
AHJ: CITY OF PORT ANGELES
(1) HOYMILES HM-300N (240V)
"AS-BUILT"
SITE PHOTOS - PV09
SITE PHOTOS:
The S-5-N 1.5 clamp is
designed for use on the
most popular 1.5" nail strip
metal roofs.The right way to attach almost anything to metal roofs! 888-825-3432 | www.S-5.com | S-5-N 1.5 and S-5-N 1.5 MiniS-5-N 1.5 Clamp
S-5-N 1.5 and S-5-N 1.5 Mini clamps
were designed with patented S-5!®
zero-penetration technology for
application on the popular 1.5" nail strip
metal roof profiles and roofing types
with similar profiles. The clamp boasts
an angular throat that accommodates
most nail strip profiles, minimizing the
need to field crimp. An angled wall with
a nose permits the S-5-N 1.5 to engage
the triangle type profiles during the
installation process—there is no longer
a need to hold the clamp in place while
setscrews are tensioned. The combination
of these two features allows the clamp
to sit straighter on the seam. Nail strip
profiles just got a whole lot simpler!
S-5-N 1.5 Mini Clamp
The S-5-N 1.5 Mini is a bit shorter
than the S-5-N 1.5 and has one
setscrew rather than two. The mini is
the choice for attaching all kinds of
rooftop accessories: signs, walkways,
satellite dishes, antennas, rooftop
lighting, lightning protection systems,
solar arrays, exhaust stack bracing,
conduit, condensate lines, mechanical
equipment—just about anything!*
*S-5! Mini clamps are not compatible with, and should not
be used with, S-5! SnoRail™/SnoFence™ or ColorGard® snow
retention systems.
Distributed byS-5!® Warning! Please use this product responsibly!
Products are protected by multiple U.S. and foreign patents. Visit the website at www.S-5.com for
complete information on patents and trademarks. Consult the S-5! website at www.S-5.com for
published data regarding installation instructions and holding strength.
Copyright 2021, Metal Roof Innovations, Ltd. S-5! products are patent protected.
S-5! aggressively protects its patents, trademarks, and copyrights. Version 083021.
The S-5-N 1.5 boasts a angular throat that accommodates most nail strip
profiles, minimizing the need to field crimp.
S-5-N 1.5 Mini Clamp
S-5-N 1.5 Clamp
Two M8-1.25
Threaded Holes
Two 3/8-24 X 0.80"
Round Point
Setscrews
M8-1.25 X 16.00 mm
Hex Flange Bolt
The S-5-N 1.5 and S-5-N 1.5 Mini clamps are each
furnished with the hardware shown to the right. Each
box also includes a bit tip for tightening setscrews
using an electric screw gun. A structural aluminum
attachment clamp, the S-5-N 1.5 is compatible with most
common metal roofing materials excluding copper. All
included hardware is 300 series stainless steel. Please
visit www.S-5.com for more information including CAD
details, metallurgical compatibilities, and specifications.
The S-5-N 1.5 clamp has been tested for load-to-failure
results on most major brands of 1.5" nail strip profiles of
standing seam roofing. The independent lab test data
found at www.S-5.com can be used for load-critical
designs and applications. S-5!® holding strength is
unmatched in the industry.
Example Profiles
ELECTRICAL INSPECTION WIRING REPORT
APPROVED NOT APPROVED
DITCH
ROUGH IN/COVER
SERVICE
FINAL
COMMENTS
Provide proper working clearance in front of combiner panel and disconnect.
NEC 110.26
NOTIFY INSPECTOR at (360) 808-2613
WHEN CORRECTIONS ARE COMPLETED
WITHIN 15 DAYS
DATE PERMIT # INSPECTOR
11/29/2023 23-876 TAP
OWNER
CONTRACTOR
Revolution Energy
PROJECT ADDRESS
306 W 3rd St
ELECTRICAL INSPECTION WIRING REPORT
APPROVED NOT APPROVED
DITCH
ROUGH IN/COVER
SERVICE
FINAL
COMMENTS
NOTIFY INSPECTOR at (360) 808-2613
WHEN CORRECTIONS ARE COMPLETED
WITHIN 15 DAYS
DATE PERMIT # INSPECTOR
12/06/2023 23-876 TAP
OWNER
CONTRACTOR
Revolution Energy
PROJECT ADDRESS
306 W 3rd ST