HomeMy WebLinkAbout4217 Fairmount Ave - Engineering
s
~~
CITY OF PORT ANGELES
PUBLIC WORKS - BUILDING DMSION
321 EAST 5TH STREET, PORT ANGELES, WA 98362
PUBILlC WORKS & R/W PERMIT
D Attached Notes
OWNER/APPLICANT
DENA CRANE
4217 FAIRMOUNT
Port Angeles, WA 98363
000/604-7903
PROJECT INFO
Work is
Plans Required
Contractor'
Performance Bond Required
Proof of Insurance
Work to Perform
Issued
12/05/2001
Permit No
Work Order'
1227
o
Value Work.
$000
PROPERTY LOCATION
4217 FAIRMOUNT AVE
Lot: 11-13
Subdivision PENN PARK
Parcel No 063008581460000
Block: 14
D Long Legal
Start Date.
Amount:
I I
Finish Date.
0001000-0000
$000
D Misc
IZI Install
D Repair
D Watermain
IZI Sanitary Sewer
D Storm Drain
D Underground Tele/Elec
PROJECT NOTES
CONNECT INTO SANITARY SEWER IN GLENWOOD NO CHARGE FOR
CONNECTION CUSTOMER HAS BEEN PAYING SAN. SEWER CHARGES
RIGHT OF WAY PERMIT AND RESTORATION ONLY TO BE CHARGED
I I
RECEIPT#8584
FEES ASSESSMENT-
1 ) R/W Excav'
2.) Sidewalk.
3 ) Curb/Gutter'
4 ) Driveway'
5 ) Dwy Culvert:
6 ) Street Cut:
7 ) Other R/W
8 ) Fire Hydrant:
9) Res Water Servo
10) Comm Water Servo
11 ) Other Water Service
12.)Water System Dev'
13 ) San Sewer SFR
14 ) San Sewer MFR
add unit: 0
$45 00
$000
$000
$000
$000
$230 00
$000
$000
$000
$000
$000
$000
$000
$000
Receipt No
Inspection Fee
RW SANITARY
g'5M
$000
WATER
15 ) Other San Sewer'
16) Sew Tap Wye/Man Tap
17 ) Sew Capl W 1M Removal
18.) Alter Repair Sewer'
19 ) Storm Drain.
20) Catch Basin per ea.
21 ) Sewer System Dev'
22.) Milwaukee Dr Sew Ass
23 ) R/W Use Perm
24 ) Admin Cost (0 RA)
25 ) 0 RA.
26 ) Misc:
TOTAL FEE.
Amount Paid
$000
$000
$000
$000
$000
$000
$000
$000
$000
$000
$000
$000
$275.00
$275 00
Balance Due.
DWY
STORM
DRA
$0.00
OTHER
Separate Permits are required for electrical work, utilities, private and public improvements. This permit becomes null and void if work or
construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned for a period of 180 days after
the work as commenced, or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have
read and examined this application and know the same to be true and correct All provisions of laws and ordinances governing this type of work
will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the
provisions of any state or local law regulating construction or the performance of construction.
Sionature of Contractor or Authorized Aoent
Date
Date
Sianature of Owner (if owner is builderl
CITY OF PORT ANGELES
DEPARTMENT dF PUBLIC WORKS
. . . . . . INSPECT"ION REPORT. . .
REQUEST
Date
Time
Received by
(phone, person)
1t/7 r~
location of Work to be inspected
Name of person requesting inspection
Address of person requesting inspection
~. e of I:nspection (circle appropriate one)
~~oundation Framing Chimney
Phone No
Permit No
Plumbing Final Sewer Excav Other
/Z2-7
Inspected
Remarks
Time
INSPECTION NOTES
/
Date
P 0'\
ByC-1A k/
RESTORATION REQUIRED
NO
YES X
j
t+
~
I~
I
~.o.
\
,1
t I
I \l
1
t
.L.
~
<.J
-.,
\)......
b<' ~
,'::"
..:-.---------
\"
"-
--.
K::;
Q
--- ~-- -------.._-".'--.~.~..._,....
'()
-- -ll
r;-;;~-:#-:-d-
c'
'" t,...
( I.'
,~
r-\
/ vi-
..(-<'
'"
l>
"
U"
\;>1
-'(e\~ \ ",e-'<
1 ~o-
I
pt)
cY---
~
/75
SURFACE RESTORATION ( 3 .K b )
SURFACE TYPE 0 Unimproved D Gravel [KJ Asphalt D pce
o Repaired by City
[] Repaired by Permittee
[] No Damage Found
/6S!rpef I ~hMo,
(Cohtinue re erse side if necessary) I
D Other
Work Order #
~ COMPlETE~
D INCOMPLETE
-(~ $ - <6-0 '2-
rr
STREET SUPERINTENDENT (DATE)
MEMO
PUBLIC WORKS
& UTILITIES
DEPARTMENT
Glenn A. Cutler
Director [4801]
Phyllis Rasler
Administrative Assistant
[4800]
Cate Rinehart
Administrative Assistant
[4700]
Ken Ridout
Deputy Director [4802]
Gary Kenworthy
Deputy Director
and
City Engineer [4803]
Scott McLain
Deputy Director [4703]
Jim Harper
Electrical Engineering Mgr
[4702]
Larry Dunbar
Power Resources Mgr
[4710]
Doyle McGinley
Water Wastewater Collection
Superintendent [4855]
Pete Burrett
Equipment Services
Superintendent [4835]
Dave Ireland
Light Operations Manager
[4731]
Jeff D Young
Treat. Plant Superintendent
[4845]
Tom McCabe
Solid Waste
Superintendent [4872]
Steve Evans
Landfill Supervisor [4873]
Mike Horton
Street Maintenance Supervisor
[4825]
~ORTANGELES
WAS H I N G TON, USA
DATE
12/11/01
TO
FILE 4217 F AIRMOUNT AVE.
FROM.
WAYNE GROFF
RE
SEWER HOOK-UP
I arnved on SIte at approXImately 1.30 Upon amval I notIced a metal structure about
3 5 feet m dIameter WhICh was level wIth the surface of the ground and full of sewer water
It appeared to be a failed septIc tank. The contractor had a dItch 7 5 feet deep and 3 feet
WIde that exposed the mam. The dItch was dug at the pomt that had been located by a City
crew that accordmg to the map should have been an eXIstmg wye. There was not a wye
at thIS locatIOn. I mstructed the contractor that Ifhe was tofnter the dItch agam, he would
eIther have to put shonng m or relIeve the SIdes of the dItch at a one to one startmg,four feet
up from the bottom of the dItch. He agreed to relIeve the SIdes. Upon relIevmg the east SIde
of the dItch, a slIce of matenal fell off exposmg an eXIstmg 6" concrete pIpe about 3' east of
the dItch SIde The pIpe headed m the general dIrectIOn of the reSIdence at 4217 FamTIount
Ave. Not knowmg the mtegnty of the 6" concrete pIpe, I mstructed t~~~tractor to tap the
mam sewer lIne and connect the new 6" PVC lIne to the saddle He~o and backfilled
the hole about half way WIth pea gravel then filled and compacted the remamder of the hole
WIth crushed rock.
~ /L~
WA~F
INSPECTOR
CITY OF PORT ANGELES
BUILDING PERMIT INSPECTION RECORD
CALL 417-4815 FOR BUILDING INSPECTIONS. PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLA WFUL TO COllER,
INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT IN A CONSPICUOUS LOCATION
KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE
INSPECTION TYPE DATE ACCEPTED COMMENTS
YES I NO
FOUNDATION:
FOOTINGS
WALLS
FOUNDATION DRAINAGE
ELECTRICAL (LIGHT DEFT)
ROUGH-IN I
PLUMBING
UNDER FLOOR I SLAB
ROUGH-IN
WATERLINE
BACK FLOW I WATER
AIR SEAL
WALLS
CEILING I
FRAMING
JOISTS I GIRDERS
SHEAR WALL
WALLS I ROOF I CEILING
DRYWALL
T-BAR
INSULATION
SLAB
WALL I FLOOR I CEILING I
MECHANICAL
CHIMNEY
WooDSTOVE I PELLET
DUCTS
PW UTILITIES I SITE WORK (Engineering Division)
WATERLINE I METER
SEWER CONNECTION
SANITARY
STORM
SITE DRAINAGE I EROSION CONTROL
PARKING
OTIlER
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCYIUSE
RESIDENTIAL DATE YES NO COMMERCIAL DATE ACCEPTED
YES NO
ELECTRICAL LIGHT DEPT 417-4746 ELECTRICAL
LIGHT DEPT
CONSTRUCTIONR.W IPWI CONSTRUCTION R. W
ENGINEERING 417-4807 PW I ENGINEERING
FIRE (MUL TI-F AM. ONLY) 417-4654 FIRE DEPT
BUILDING 417-4815 BUILDING
GENERAL COMMENTS:
PW-1l02.15 (4196]