HomeMy WebLinkAbout316 W 9TH ST - Building (2)ELECTRICAL PERMIT
CITY OF PORT ANGELES
360-417-4735
Application Number . . . . . 18-00000718 Date 5/10/18
Application pin number . . . 958002
Property Address . . . . . . 316 W 9TH ST
ASSESSOR PARCEL NUMBER: 06 -30 -00 -0 -2 -9415 -0000 -
Application type description ELECTRICAL ONLY
Subdivision Name . . . . .
Property Use . . . . . . . .
Property Zoning . . . . . . . RS7 RESDNTL SINGLE FAMILY
Application valuation . . . . 0
----------------------------------------------------------------------------
Application desc
PV system
----------------------------------------------------------------------------
Owner Contractor
------------------------ ------------------------
PAMELA WILDER/DAVID S MATTERN POWER TRIP ENERGY CORP.
316 W 9TH ST 83 DENNY AVE
PORT ANGELES WA 98362 PORT TOWNSEND WA 98368
(206) 300-1798 (360) 643-3080
----------------------------------------------------------------------------
Permit . . . . . . ELECTRICAL ALTER RESIDENTIAL
Additional desc . .
Permit Fee . . . . 165.00 Plan Check Fee .00
Issue Date . . . . 5/10/18 Valuation . . . . 0
Expiration Date . . 11/06/18
Qty Unit Charge Per Extension
1.00 102.0000 ECH EL -RENEWABLE 5-KVA OR LESS 102.00
1.00 63.0000 BCH EL -R- BRANCH CIR WO/ SER FEED 63.00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
------------------------------------- ---------- ----------
Permit Fee Total 165.00 165.00 .00 .00
Phan Check Total .00 .00 .00 .00
Grand Total 165.00 165.00 .00 .00
INSPECTION TYPE
DATE:
DITCH
SERVICE
ROUGH -IN
FINAL
COMMENTS:
PERMIT WILL EXPIRE SIX (6) MONTHS FROM LAST INSPECTION
Signature of owner or Electrical Contractor X
RESULTS:
to
REPORT STATE SALES TAX
on your excise tax form
to the City of Port Angeles
(Location Code 0502)
INSPECTOR:
Date:
CITY OF PORT ANGELES PERMIT APPt,icA'T'lON
Building Division/Electrical Inspections
321 Fast Filth Street — P.O. Box 1150 / Port Angeles Washington, 98362
Ph: (360) 317-4735 Fax: (360) 417-4711
Date 2/13/2418
__ 1 & 2 Single Family Dwelling
` Plan Review May Be Required, Please Complete Electrical Plan Review Information Sheet
Job Address 3-16 WEST_ -9THSTREET,-
PORT ANGELES,__ . WA 98362
Budding Square Footage:
Descrption of above
GRUY-TI - ROui, muum,Eij
PV- -- -
Owner Information
Contractor Information
Name David Mattern an(3 Pameis
Wilde~ Name Powe?
tytadm Address 8I 9Tfl_IF1=J,
g
PORT A",
Flailing Address _ "' "r r
. .
F+'•' °_ — -- --
C:ity -- -State 111(A Zip ...._
98 62— rJt r.. t .. State
-- —
:;, ZIP
Phone �F-t17g8 Fax ---- -
-- hone j :. -.Y ; �. ;Fax
License #'Exp
License V. Exp
1< EXP 4 i-• µ
1WM
Unit Charge Sky Total
(Qty Multiplied by Unit Charge)
Service/Feeder 200 Amp
S 12000
S __
Service/Feeder 201-400 Amp.
S 146.00 _
S _ -
ServiceiFeeder 401 600 Amp
S 205 00
S-
Service'Feeder 601-1Ci00 Amp
S26200
S
ServicelFeeder over 1000 Amp
$ 373 00
$
Branch Circuit Wi Service Feeder
S 5 00
S
Branch Circuit W10 Service Feeder
S 6300
Each Additional Branch Circuit
S 500
Branch Circuits 1 4
S 75 00
$
Temp Servicef Feeder 200 Amp
S 9300
Tenlp ServicelFeeder 201400 Ainp.
S 11000
S
I emp Service?Feeder 401.600 Amp
S 149 00
S_ —
Temp Service!Feeder 601-1000 Amp
S 168 0C'
Portal to Portal Hourly
S 96 00 _
$
Signal Circuit Limited Energy 1 & 2 Family Dwelling
S 6400
Manufactured Home Connection
$ 12000
Renewable Electrical Energy - SKVA System or Less
S 10200 '
S__ ._ 1
Thermostat
$ %00 _ _
S
Note S5 00 for each additional T-Stat
NEW CONSTRUCTION ONLY:
First 1300 Square Ft.
S 120..10
Each Additional 500 Square Ft or Portion of
S 40, DO
Each Oulbuildmg or Detached Garage
S 74 00
Each Swimming Pool or Hot Tub
S 11000
Total
Owner as defined by RCW 19.28.261 (1) Owner
will occupy the structure for two years after this electrical permit
is finalized (2) Owner is required
to hire an electrical contractor if above said property is for sale, rent or lease Permit expires after six months of last inspection
After reading the above statement. I hereby certify that I am the owner of the above named property or a licensed electrical contractor I am making
the electrical installation or alteration in compliance with the electrical laws. N E C . RCW Chapter 19 28, WAC Chapter 296-46B The City of Port
Angeles Municipal Code. and Utility Specifications and PAMC 14 05 050 regarding Electrical Permit Applications.
Signature of owner, electrical con
,liactor or electrical administrator: cash Check
% rl Credit Card #
A 7 r f Dated: r + 0110112012
Notes: Upgrading Main Service Panel
-,r
,,,ties. WA 98362
. .j, is -lied Roof Mounted Solar
(24)Sun:Power
SPR -X21 -335 -C -AC
Modules with
integrated
Micretriverters'bri
East Fach*W.Roof
Design -Driven Advantages
#1 module aesthetics and efficiency'
Unmatched module reliabilityz
No electrolytic capacitors
25 -year Combined Power and Product
Warranty
Maximize Value for Roof
Size system for roof, not string inverter
Optimize performance of each module
Expand Deployment Options
Complex roofs and partial shading
Small systems
System expandability
Simplify & Speed Installation
Factory -integrated microinverter
Robust, double-IockingAC connectors
Design flexibility offsite and onsite
No DC string sizing process
Fewer: nsallation steps than competing
systems
Intuitive commissioning
Component of Complete System
Built for use with SunPowerO' InvisiMount1m
and the SunPower Monitoring System
Superior system reliability and aesthetics
Optimize System and Installation Efficiency
SERIES
SunPower` AC Modules, whi& ;rclude a factory -integrated
SunPower microinver.er, provide a revolutionary combination of high
efficiency, high reliability, and module -level DC -to -AC power conversion.
Desigred specifically for use with SunPower InvisiMountTm and the
SunPower Monitoring System, SunPower AC Modules eraole rapid
installation, best -in -class system aesthetics, and intuitive visibility into
system performance. All this cores with the best Combined Power
and Product Warranty it the industry.
sunpower.com
Ftfi�r Data
SPRA21-335-131-K-C-AC SPR-)UG-327-131LK C AC
Nominal Power'(Pnom) 335 W 327 'JJ
Power Tolerance +5/-0% +5/-0%
Avg. Panel Efficiency° 21.0% 20.4%
Temp. Coe`. (Power) -0.29%/°C
Three bypass diodes
Shade Tolerance • Integrated module -level maximum power
point tracking
No active phase balancing for 3 prase
installations
Mechanical Data
Output @ 240 V (min./nom /max.)
211/240/264 V
Output @ 208 V (min /nom./max.)
183/208/229 V
Operating Frequency (min./nom.1max.)
59.3/60.0/60.5 Hz
Output Power Factor (min.)
0.99
AC Max. Continuous Output Current @ 240 V
1.33 A
AC Max. Continuous Output Current @ 208 V
54 A
AC Max Cont. Output Power
320 W
DC/AC CEC Ccnve,slon Efficiency
96.0%
Max. t r is Per 20 A Branch Circuit @ 240 V
2 (single phase)
Max. Units Per 20 A Branch Circuit @ 208 V
0 (two pole)
No active phase balancing for 3 prase
installations
i-igi,es tit �,,r 3,204 A car sola, ranee .,-hutnn`.lnduh- >,.r. e,mar 2'� I -i
#1 rarb m 'P;'AA,1, L,uraotla,, 'na lro— I iclic Pepor<,, F,aurl c. e, :3 -rr, "!13 -ire _t of
the :2p eight lar5est manufacturers+sere tesed Cemr�ea I' i , r,l \ r°.:,ne P,'.or:ule
Seg ,dation Rate' sur: ow, e hite paper, =eo 20"I gee nwvv ;,,npo`ne :^m n t3 for jetai(s
d - s. ).. ,.;i„: rr3diance, a'.' 1 -1 2> -1 9F'. ,auti-,., r. s[. -torr . AV,
all l_-.;It.3?s a+uli, rnI,it t vi,h,r rr
Eased^r a' _ ;,=e',i rr ea,,.reJ r^v,ti .,1bat-.-:r,rma or^o..crv,nr
Pd Oaerating i til
Operat ng Temp. -40° F to -1 85° F (-40° C to *85° C)
Max Amblen.t
j Temp. 122° F (50° q
Max Loao Wind 62 psf, 3000 Pa, 305 kg/m2 front & back
Snow: 125 psf, 6000 Pa, 611 kg/m- front
1 Inch ,25 mm) diameter nail at 52 mph (23
Impar' Resistance
j S)
WarraOties • Certifications
'Nan °hues 25 -year im ted power warranty
25 -year limited product warranty
U1_ listed �L 1741, rd,:c't' :
IEEE1547/ 547a and IEEE1547 1/1547 is Utility
Interactive
PV Rapid Shutdown Equipment
Equipment Grourding
6703, UL 9703 Connectors and cables (ioao
break disconnection)
UL 1703 PV Modules (Type 2 fire raying;
Certifications Enabies nstallation In accordance'vitli:
NEC 690.6
NEC 690.12 Rapid Shutdc,,vn (inside and outside
the array)
NEC 691u.'5 All Connectors, 690.33(A) - ;E)(1)
FCC and ICES -003 Class B
W ,en used with Inv sl`vlcunt racking (UL 2703)
Integrated grounding and bonding
Cass Afire rated
PIC 'es. Potent'al-induced degradation Tree
♦
280-_
(1 1,02 rnj
o6 ] inx
[.13 6 in1046 mm
1 at Z rnj
i 30 mm
'.1 2 in7
1558 mm
(613,,7 —__--- - - ---
Please read the safety and installation instructions for details
dee"Pla sbrp7,e, .or'i`acis to,—cl '_ ('ta. er:= r.I^,,r-. L,[
-or r'c-e retails, see e xtencec oatasheet www s,;r Fowe' _nr, wrasFeets Document # 515216 Rev D iL fR us
Mechanical Data
Sdar Cells
96 Mo-�ocrystalllne Maxeorl Gen Ili
Front Glass
-Ign-='ansmission tempered glass wit,
anti -reflective coating
Envimnme^tai Rating
Outdoor rated
Frame
Cass 1 black anodizea (h gnest AAMA
atirg)
Weight
45 5 bs (20.6 kg)
Max..Recommencec
Module S, ng
.3 In. (33 mm)
i-igi,es tit �,,r 3,204 A car sola, ranee .,-hutnn`.lnduh- >,.r. e,mar 2'� I -i
#1 rarb m 'P;'AA,1, L,uraotla,, 'na lro— I iclic Pepor<,, F,aurl c. e, :3 -rr, "!13 -ire _t of
the :2p eight lar5est manufacturers+sere tesed Cemr�ea I' i , r,l \ r°.:,ne P,'.or:ule
Seg ,dation Rate' sur: ow, e hite paper, =eo 20"I gee nwvv ;,,npo`ne :^m n t3 for jetai(s
d - s. ).. ,.;i„: rr3diance, a'.' 1 -1 2> -1 9F'. ,auti-,., r. s[. -torr . AV,
all l_-.;It.3?s a+uli, rnI,it t vi,h,r rr
Eased^r a' _ ;,=e',i rr ea,,.reJ r^v,ti .,1bat-.-:r,rma or^o..crv,nr
Pd Oaerating i til
Operat ng Temp. -40° F to -1 85° F (-40° C to *85° C)
Max Amblen.t
j Temp. 122° F (50° q
Max Loao Wind 62 psf, 3000 Pa, 305 kg/m2 front & back
Snow: 125 psf, 6000 Pa, 611 kg/m- front
1 Inch ,25 mm) diameter nail at 52 mph (23
Impar' Resistance
j S)
WarraOties • Certifications
'Nan °hues 25 -year im ted power warranty
25 -year limited product warranty
U1_ listed �L 1741, rd,:c't' :
IEEE1547/ 547a and IEEE1547 1/1547 is Utility
Interactive
PV Rapid Shutdown Equipment
Equipment Grourding
6703, UL 9703 Connectors and cables (ioao
break disconnection)
UL 1703 PV Modules (Type 2 fire raying;
Certifications Enabies nstallation In accordance'vitli:
NEC 690.6
NEC 690.12 Rapid Shutdc,,vn (inside and outside
the array)
NEC 691u.'5 All Connectors, 690.33(A) - ;E)(1)
FCC and ICES -003 Class B
W ,en used with Inv sl`vlcunt racking (UL 2703)
Integrated grounding and bonding
Cass Afire rated
PIC 'es. Potent'al-induced degradation Tree
♦
280-_
(1 1,02 rnj
o6 ] inx
[.13 6 in1046 mm
1 at Z rnj
i 30 mm
'.1 2 in7
1558 mm
(613,,7 —__--- - - ---
Please read the safety and installation instructions for details
dee"Pla sbrp7,e, .or'i`acis to,—cl '_ ('ta. er:= r.I^,,r-. L,[
-or r'c-e retails, see e xtencec oatasheet www s,;r Fowe' _nr, wrasFeets Document # 515216 Rev D iL fR us
ELECTRICAL PERMIT
CITY OF PORT ANGELES
364-417-4735
Application Number . . . . . 18-00000718 Date 5/10/18
Application pin number . . . 958002
Property Address . . . . . . 316 W 9TH ST
ASSESSOR PARCEL NUMBER: 06 -30 -00 -0 -2 -9415 -0000 -
Application type description ELECTRICAL ONLY
Subdivision Name . . . . .
Property Use . . . . . . . .
Property Zoning . . . . . . . RS7 RESDNTL SINGLE FAMILY
Application valuation . . . . 0
----------------------------------------------------------------------------
Application desc
PV system
----------------------------------------------------------------------------
Owner Contractor
------------------------ ------------------------
PAMELA WILDER/DAVID S MATTERN POWER TRIP ENERGY CORP.
316 W 9TH ST 83 DENNY AVE
PORT ANGELES WA 98362 PORT TOWNSEND WA 98368
(206) 300-1798 (360) 643-3080
----------------------------------------------------------------------------
Permit . . . . . . ELECTRICAL ALTER RESIDENTIAL
Additional desc . .
Permit Fee . . . . 165.00 Plan Check Fee .00
Issue Date . . . . 5/10/18 Valuation . . . . 0
Expiration Date 11/06/18
Qty Unit Charge Per Extension
1.00 102.0000 ECH EL -RENEWABLE 5-KVA OR LESS 102.00
1.00 63.0000 BCH EL -R- BRANCH CIR WO/ SER FEED 63.00
--------^--------------- 7 ---------------------------------------------------
Fee summary Charged Paid Credited Due
Permit Fee Total 165.00 165.00 .00 .00
Plan Check Total .00 .00 .00 .00
Grand Total 165.00 165.00 .00 .00
,0
REPORT STATE SALES TAX
on your excise tax form
to the City of Port Angeles
(Location Code 0502)
1
/f
INSPECTION TYPE DATE: RESULTS: INSPECTOR:
DITCH
SERVICE
ROUGH -IN 5 , A / l g
FINAL A
COMMENTS:
PERMIT WILL EXPIRE SIX (6) MONTHS FROM LAST INSPECTION
Signature of owner or Electrical Contractor X
is —
Date:
l
—j
CITY OF PORT ANGELES PERMIT APPLICATION
Building Division/Electrical Inspections
321 Fast Fifth Street — P.O. Box 1150 / Port Angeles Washington, 98362
Ph: (360) 317-4735 Fax: (360) 417-3711
Date 2113120.18
1 & 2 Single Family Dwelling
` Plan Review May Be Regw_ired, Please Complete Electrical Plan Review Information Sheet
Job Address _316 WES _ 9TH STREET,_ POR_ T_ ANGEL_ ES,-- WA 983_-62_
Building Square Footage .
:$PROX- 3-0 SQF`F -- - - - - ---
Description of above-
GRTIS TIED -RUUr' MUuNTED PV- --
Owner Information
Name
g David Mattern anti Pamela wieder
(lading ORTSA to ._ T_ __81REET -
.rtv P_�-__ . _..--- State VVA - Zip __-98362_
Phone 206-300-1798 Fax
License Al I Exp
r
Contractor information
Name Power c eri : qY _ i n
Mailing Address
,ty r .:a State _ hA Zip n
Phone s ',-Fax
License # . Exp ._ P,: W _H ='E ),A, t. EXP 4 ,
Rom
Unit Charge
Qty Total {Qty Multiplied by Unit Charge)
Service/Feeder 200 Amp
S 12000
S -.--__
ServicelFeeder 201-400 Amp
S 146.00
- - _ S _ _ -
Service;Feeder 401 600 Amp
S 20S 00
5 _ --
Service Feeder 601-1000 Amp
S 252 00
5
Service Feeder over 1000 Amp.
$ 37300
_ S
Branch Circuit * Service Feeder
S 5100
Branch Circuit WO Service Feeder
S 63 OU
S
Each Additional Branch Circuit
S 500
_-, ._ $
Branch Circuits 1-4
S 7506
$
Temp Service? Feeder 200 Amp
S 9300
S
Temo Service/Feeder 201400 Amp.
S 110 00
Temp Service�Feeder 401.600 Amp
S 149 CA)
- S-_- - ----
Temp Service'Feeder 601-1000 Amp
S 138 00
$
Portal to Portal Hourly
S 96 00
_ S
Signal Circuit" Limited Energy _ 1 & 2 Family Dwelling
S 6400
_ S-_
Manufactured Home Connection
$ 120 00
S
Renewable Electrical Energy 5KVA System or Less
S 10200
Thermostat
S 56
Note S5 00 for each additional T-Stat
CONSTRUCTION ONLY:
NEW
First 1300 Square Ft.
S 120 10
Each Additional 500 Square Fl or Portion of
S 40 00
Each Outbuilding or Detached Garage
S '4 00
S __
Each Swimming Pool or Hol Tub
S 11000
$
$ i `, `, Total
Owner as defined by RCW 19.28.261 (1) Owner will
occupy the structure for two years after this electrical permit is finalized (2) Owner is required
to hire an electrical contractor if above said property is for sale, rent or lease Permit expires after six months of last inspection
After reading the above statement. I hereby certify that I am the owner of the above named property or a licensed electrical contractor I am making
the electrical installation or alteration in compliance with the electrical laws. N E C . RCW Chapter 19 28, WAC Chapter 29646B, The City of Port
Angeles Municipal Code, and Utility Specifications and PAMC 14 05 050 regarding Electrical Permit Applications,
Signature of owner, electrical cont4actor or electrical administrator: C: cash check
7
Credit Card R
1 L -rte. i f 1
1.. L / Oated r 1 f 01101/2012
Notes: Upgrading Main Service Panel
— . r.%l 1geles. WA 98362
urid-Tied Roof Mounted Solar
(24)SunPower
SPR -X21 -335 -C -AC
Modules with
integrated
4
Microinverters on
EastFacing
Design -Driven Advantages
#1 module aesthetics and efficiency'
Unmatched module reliabilityz
No electrolytic capacitors
25 -year Combined Power and Product
Warranty
Maximize Value for Roof
Size system for roof, not string inverter
Optimize performance of each module
Expand Deployment Options
Complex roofs and partial shading
Small systems
System expandability
Simplify & Speed Installation
Factory -integrated microinverter
Robust, double-IockingAC connectors
Design flexibility offsite and onsite
No DC string sizing process
Fewer installation steps than competing
systems
Intuitive commissioning
Component of Complete System
Built for use with SunPowerO InvisiMountlm
and the SunPower Monitoring System
Superior system reliability and aesthetics
Optimize System and Installation Efficiency
SERIES
SunPower' AC Modules, which include a factory -integrated
SunPower microinverter, provide a revolutionary combination of high
efficiency, high reliability, and module -level DC -to -AC power conversior.
Designed specifically for use with SunPower !rvisiMountlm and the
SunPower Monitoring System, SunPower AC Modules enable rapid
installatior, best -in -class system aesthetics, and intuitive visibility into
system performance. All -his comes with the best Combined Power
and Product Warranty in the industry.
sunpower.com
Power,Data
SPRA21-335-BLKC-AC SPR-X20-327-BLK-C-AC
Nominal Power'(Prom) 335 W 327 W
Power Tolerance +5/-0% -5/-0%
Avg. Panel Efficiency' 21.0% 20.4%
;
Temp. Coe ;Power) -0.29%/'C
Three bypass diodes
Shade Tolerance Integrated module -level maximum power
point tracking
AC Electrical Data
Mechanical D.
Output @ 240 V (min./nom./max.)
211/240/264 V
Output @ 208 V (min./nom./max.)
183/208/229 V
Operating Frequency (min./nom./max.)
59.3/60.0/60.5 Hz
Output Power Factor (min.)
0.99
li AC Max. Cor-in�ous Output Current @ 240 V
1 33 A
AC Max Continuous Output Current @ 208 V
154 A
AC Max. Cort. Output Power
320 W
DC/AC CEC Conversion Efficiency
96.0%
Max. ,;nits Per 20 A Branch Circuit @ 240 V
2 (single phase)
Max. Units Per 20 A Branch Circuit @ 208 V
10 (two pole)
No active phase balancing for 3 phase
installations
1"gli 3 0n,[icon snisi ojnel`, �Mlun Vodule 3�,.e, =eb 20 u
x1 rark in 'PV vuci,le .,rau [it, nm -u rt P ubI r pepnrC' . ra note C;r. �-n ?013 =ee rI of
the rpp Pirii arges, mdrufact.,re-,'+,er-cestea Campeau,.'_ =t,,i �_wiPnod'uIe
Deg, icatinn Rate" - ,r--wei ,vi,rte raper =en 20 i i >e, NAw,unpowcr mo, f, -:_r; `r,, stat IIs
.9nbrtinr3,i '_� .Lr �=ir�:diarv_ 4', _ _. _,. •.RS r:ii'r -„�r rrc.r7. A-, collage 4 �2 = .;,iGae s t,.lh = ntain i rd , i ri-� �,:nul,
reas., ,ire,•. _, an.c_ ....•erg c:
Pd Onnratlne Cone
Operating Temp. -40' F to -185' F (-40' C to -85' Q
Mai., Ambient 22o F (50' Q
Temp.
Max 'Load
Wand. 62 psf, 3000 Pa, 305 sig/m2 front & back
Snow: 125 psf, 6000 Pa, 61 1 kg/ml front
nch (25 mm) diameter nail at 52 mph (23
Impact Resistance
Warranties i Certifications
iia—anttes
25-year'Im,ted power warranty
25 -year limited prods ct vvarrar'ty
UL listed tc _L 17=11. rc!t;cing:
IEEE1 547/1 547a and IEEE1547 ' 547 1 a Utility
Interactive
PV Rapid Shutdown Equipment
Equ;pn;e^t Grounding
U! 6703, UL 9703 Connec*ors and cables (loae
break disconnection)
1703 PV Modules (Type 2 fire rating`,
Certifications Enables Installation it accordance with:
NEC 690.6
NEC 690.12 Rapid Shutdown (inside and octside
I
the array)
NEC 690 15 AC Connectors, 690 HA) - (E)(1)
FCC and ICES -003 Class B
When ,sea ✓-h InvislMount racrirg;UL 2703)
Integrated grounoirg and bcrding
--''ass A fire rates
PIG Tes: Potential -Induced degracat or `ree
280 mm
11 12 .n1
[10 107 mm " 11 II
6 in) tu46 mm �Iillullll�
;41 ? in]
__ 30 mm
n7
r
1558 mm
[61 3 int ----- --�"
Please read the safety and Installation instructions for details
-ee n,.;n„surpcve, _nr^rSsc's to, rnn,e iefe—r-e raci-aTinr
for ^cre details, see exterce7 datasneet w,,,PN surpowr, ,-^r-,/raatasheets Docwnent # 515316 Rev D /LTR_US
Mechanical D.
Solar Cei!s
96 Monocrystaiiine Vlaxeon Gen III
n J t Glass
_lgh-tra^smission tempered glass with
arti-reflective coating
Environmental Rating
Ou:ecor rated
Frame
Cass 1 clac. anodized (r:grestAAIMA
rating)
Weight
45 5 bs ;20.6 kg)
Max Recomrre-.ced
.3 in. (33 mm)
MocL-!e Spacing
1"gli 3 0n,[icon snisi ojnel`, �Mlun Vodule 3�,.e, =eb 20 u
x1 rark in 'PV vuci,le .,rau [it, nm -u rt P ubI r pepnrC' . ra note C;r. �-n ?013 =ee rI of
the rpp Pirii arges, mdrufact.,re-,'+,er-cestea Campeau,.'_ =t,,i �_wiPnod'uIe
Deg, icatinn Rate" - ,r--wei ,vi,rte raper =en 20 i i >e, NAw,unpowcr mo, f, -:_r; `r,, stat IIs
.9nbrtinr3,i '_� .Lr �=ir�:diarv_ 4', _ _. _,. •.RS r:ii'r -„�r rrc.r7. A-, collage 4 �2 = .;,iGae s t,.lh = ntain i rd , i ri-� �,:nul,
reas., ,ire,•. _, an.c_ ....•erg c:
Pd Onnratlne Cone
Operating Temp. -40' F to -185' F (-40' C to -85' Q
Mai., Ambient 22o F (50' Q
Temp.
Max 'Load
Wand. 62 psf, 3000 Pa, 305 sig/m2 front & back
Snow: 125 psf, 6000 Pa, 61 1 kg/ml front
nch (25 mm) diameter nail at 52 mph (23
Impact Resistance
Warranties i Certifications
iia—anttes
25-year'Im,ted power warranty
25 -year limited prods ct vvarrar'ty
UL listed tc _L 17=11. rc!t;cing:
IEEE1 547/1 547a and IEEE1547 ' 547 1 a Utility
Interactive
PV Rapid Shutdown Equipment
Equ;pn;e^t Grounding
U! 6703, UL 9703 Connec*ors and cables (loae
break disconnection)
1703 PV Modules (Type 2 fire rating`,
Certifications Enables Installation it accordance with:
NEC 690.6
NEC 690.12 Rapid Shutdown (inside and octside
I
the array)
NEC 690 15 AC Connectors, 690 HA) - (E)(1)
FCC and ICES -003 Class B
When ,sea ✓-h InvislMount racrirg;UL 2703)
Integrated grounoirg and bcrding
--''ass A fire rates
PIG Tes: Potential -Induced degracat or `ree
280 mm
11 12 .n1
[10 107 mm " 11 II
6 in) tu46 mm �Iillullll�
;41 ? in]
__ 30 mm
n7
r
1558 mm
[61 3 int ----- --�"
Please read the safety and Installation instructions for details
-ee n,.;n„surpcve, _nr^rSsc's to, rnn,e iefe—r-e raci-aTinr
for ^cre details, see exterce7 datasneet w,,,PN surpowr, ,-^r-,/raatasheets Docwnent # 515316 Rev D /LTR_US
INSPECTION TYPE
DATE:
DITCH
SERVICE
o
ROUGH -IN
to 1,g) Its
FINAL
COMMENTS:
A%RMIT WILL EXPIRE SIX (6) MONTHS FROM LAST INSPECTION
Sipature of owner or Electrical Contractor X
RESULTS:
REPORT STATE SALES TAX
Cit? y9or axd$&tax form
to the City Cif Pod Angeles
(Location Code 0502)
INSPECTOR:
Date:
ELECTRICAL PERMIT
CITY OF PORT ANGELES
300-417-4735
Application Number . . . . ..
18-00000373 Date 3/21/18
Application pin number . . .
375541
Property Address . . . . . .
316 W 9TH ST
ASSESSOR PARCEL NUMBER:
06 -30 -00 -0 -2 -9415 -0000 -
Application type description
ELECTRICAL ONLY
Subdivision Name . . . . . .
Property Use . . . . . . . .
Property Zoning . . . . . . .
RS7 RESDNTL SINGLE FAMILY
Application valuation . . . .
0
-------------------------------------
Application desc
7 --------------------------------------
Hood fan
----------------------------------------------------------------------------
Owner
Contractor
------------------------
PAMELA WILDER/DAVID S MATTERN
-----------------------
EXTRA MILE TECH & ELECT., LLC
316 W 9TH ST
418 N. RACE ST.
PORT ANGELES WA 98362
PORT ANGELES WA 98362
(206) 300-1798
(360) 457-5222
---------------------- : --------------------- 7 --------------------------------
Permit . . . . . . ELECTRICAL ALTER RESIDENTIAL
Additional desc . .
Permit Fee . . . . 63.00
Plan Ch6ck Fee .00
Issue Date . . . . 3/21/18
valuation . . . . 0
Expiration Date . . 9/17/18
Qty Unit Charge Per
Extension
1.00 63,0000 BCH EL -R-
BRANCH CIR WO/ SER FEED 63.00
----------------------------------------------------------------------------
Fee summary charged
-----------------
Paid Credited Due
----------
Permit Fee Total 63.00
---------- ---------- ----------
63.00 .00 .00
.Plan Check Total .00
.00 .00
Grand Total 63.00
63.00 .00 .00
INSPECTION TYPE
DATE:
DITCH
SERVICE
o
ROUGH -IN
to 1,g) Its
FINAL
COMMENTS:
A%RMIT WILL EXPIRE SIX (6) MONTHS FROM LAST INSPECTION
Sipature of owner or Electrical Contractor X
RESULTS:
REPORT STATE SALES TAX
Cit? y9or axd$&tax form
to the City Cif Pod Angeles
(Location Code 0502)
INSPECTOR:
Date:
1
yam:
1 — 2 SINGLE—FAMILY IMAR 1 c, 2oni
ELECTRICAL PERMIT APPLICATION EjECTROL
Public Works and Utilities Department INSPECTIONS
1 � 321 E. 5th Street, Port Angeles, WA 98362
360.417.4735 1 www.cityofpa.us I electricalpermits@cityofpa.us
ProjectAdd,ress: 31(,
-i ►c,¢/a�}
Pro' Descripfion: 1N -e- t'Zc-w
'S/
*0fit�od
�/1�
Single -Family Residential ❑ Duplex / ARU
Budding Square footage:
Name:
Email: 10 / x
Mailing Address: 31 tl�tsfr q
�"`� S{'r� -
phone: .0- O 4 -3 oo " (7 g f
Igo
Name: FX7'24 l►'[: L,E —1
t3 9 le,_f-► cq I
tjcense:,'XrR407r 973 R �
Mailing Address: P-0- 3 0A 3 I X8
SPA Q 9 3 (P?-
Expiration Date: 112-A40-2011
Email: S -X f zA- h7 ♦ LE (F O /vol a
Ks. NET'
Phone:
Unit Chargg
jg[ (Qua m ft x Unit Cterge)
ServiCelFeeder 200 Amp.
$120.00
$
ServicelFeeder 201-400 Arra.
$146.00
$
Servic elFeeder 401-6W Amp
$205.00
$
Sir 601-1000 Amp.
$26200
$
ServiceiFeeder over 10W Amp.
$37300
$
Branch Circuit W1 Service Feeder
$5.W
$
Branch Circuit VM Service Feeder
$63.00 _�
$ �3 • `�
Each Additional Branch Circuit
$5.00
$
Branch Cacuits 1-4
$75.00
$
Temp. Secvic afFe iter 200 Amp.
$9300
$
Temp. ServicelFeeder 201-400 Amp.
$110.00
$
Temp. ServiceiFeeder401-600 Amp.
$149.00
$
Temp. Servk&TbWer601-1000 Amp.
$168.00
$
Portal to Portai Hourly
$.96.00
$
Signal Cirauitlt.imited Energy -182 DU.
$64.00
$
Manufactured Hoare Connection
$120.00
$
Renewable Elec. Energy. 5KVA SyMem or less
$10200
$
Thermostat (Nobe: $5 for each additional)
$56.00
$
Fust 1300 Square Feet
$120.00
S
Each Additional 500 square feet'
$40.00
$
Each Oulbuildmg 1 Detached Garage
$74.00
$
Each Shwrrtrtuirug Pool 1 HotTub
$110.00
$
TOTAL $ rv� • ' `�
Owner as defined by RCW.1928261: (1) Owner will occupy the structure for two years after this electrical permit is finalized. (2) Owner is
required to We an electrical contractor if above said property is for sale. Wert or lease. Permit expires atter six months of last inspection.
After reading the above statement, I hereby certify that 1 am the owner of the above named property or a licensed electrical contractor. l
am making the electrical installation or allemtion in compliance with the electrical laws, N _E.C_, RCW. Chapter 19.28, WAC. Chapter 296-
468, The City of Port Angeles Municipal and Utility Specifications and PAMC 14.071eccftal
Elecb'ical Permit Applications.
Date Print Dame Signature([] OwnerContractor i Administrator)
[Electrical PermitAppiications may be submitted to City Hall or electricalpermitsCatyofpa us or faxed to 360.417.4711]
m
3
7�