HomeMy WebLinkAbout1902 W 6TH ST - Building (2)ELECTRICAL PERMIT
CITY OF PORT ANGELES
360-417-4735
Application Number . . . . . 17-00001617 Date 11/03/17
Application pin number . . . 990317
Property Address . . . . . . 1902 W 6TH ST
ASSESSOR PARCEL NUMBER: 06 -30 -00 -8 -5 -0100 -0000 -
Application type description ELECTRICAL ONLY
Subdivision Name . . . . . .
Property Use . . . . . . . .
Property Zoning . . . . . . . RS7 RESDNTL SINGLE FAMILY
Application valuation . . . . 0,
---------7------------------------------------------------------------------
Application desc
PV system
-----------=----------------------------------------------------------------
Owner Contractor
CAMMY AND JOHN THOMAS SMART ENERGY TODAY,
INC
1902 W 6TH ST 2120 STATE AVE NE STE 103
PORT ANGELES WA 983631610 OLYMPIA
WA 98506
(360) 431-3103' (888) 405-8689
----------------------------------------------------------------------------
Permit . . . . . . ELECTRICAL ALTER RESIDENTIAL
Additional desc . .
Permit Fee . . . . 102.00 Plan Check Fee
.00
Issue Date . . . . 11/03/17 Valuation . . .
. 0
Expiration Date 5/02/18
Qty Unit Charge Per
Extension
1.00 102.0000 ECH EL -RENEWABLE 5-KVA OR LESS
102.00
- --------------------------------------------------------------------------
Fee summary Charged Paid Credited
-------------------- ---------- ----------
Due
-----------------
Permit Fee Total 102.00 102.00 .00
.00
Plan Check Total .00 .00 .00
.00
Grand Total 102.00 102.00 .00
.00
REPORT STATE SALES TAX
on your excise tax form
to the City of Port Angeles
(Location Code 0502)
INSPECTION TYPE DATE: RESULTS: 1 INSPECTOR:
DITCH
SERVICE
ROUGH -IN �-7' 05
FINALCAW
COMMENTS:
PERMIT WILL EXPIRE SIX (6) MONTHS FROM LAST INSPECTION
Signature of owner or ElectricalCotoactor X Date:
�F z
After reading the above statement, I hereby certify that I am the owner of the above named property or a licensed electrical contractor. I am making
the electrical installation or alteration in compliance with the electrical laws, N.E.C., RCW. Chapter 19.28, WAC. Chapter 296-46B, The City of Port
Angeles Municipal Code, and Utility Specifications and PAMC 14.05.050 regarding Electrical Permit Applications.
Signature of owner, electrical contractor or electrical administrator: ❑ cash V Check
❑ Credit Card #
X /� r Dated: /0/;3/17 0110112012
pukt
CITY OF PORT ANGELES PERMIT
APPLICATION
��•
Building Division/Electrical Inspections
321 East Fifth Street — P.O. Box 1150 / Port Angeles Washington, 98362
Ph: (360) 417-4735 Fax: (360) 417-4711
Date: 10193117
V 1 & 2 Single Family Dwelling
* Plan Review May Be Required, Please Complete
Electrical Plan Review Information Sheet
Job Address: 1902 W 6th St Port Anaeles. WA 98363
Building Square Footage: 1 nn9 qq ft
Description of above Single family residence
Owner Information
Contractor Information
Name: John & Cammv Thomas
Name: Smart Enerav
Todav
Mailing Address: 1902 W 6th St
Mailing Address: 1001 C000er Point Rd SW Ste. 140-290
City: Port Angeles State: WA Zip: 98363
City: CH nin
State: WA Zip: 98502
Phone: (360) 431-3103 Fax:
Phone: 360-339-6660
Fax:
License # / Exp.
License # / Exp. SMARTET869RJ
Item
Unit Charge Qty
Total (Qtv Multiplied by Unit Charae)
ServicelFeeder 200 Amp.
$120.00
$
ServicelFeeder 201-400 Amp.
$ 146.00
$
Service/Feeder 401-600 Amp
$ 205.00
$
Service/Feeder 601-1000 Amp.
$ 262.00
$
Service/Feeder over 1000 Amp.
$ 373.00
$
Branch Circuit W/ Service Feeder
$ 5.00
$
Branch Circuit W/O Service Feeder
$ 63.00
$
Each Additional Branch Circuit
$ 5.00
$
Branch Circuits 14
$ 75.00
$
Temp. Service/ Feeder 200 Amp.
$ 93.00
$
Temp. Service/Feeder 201-400 Amp.
$110.00
$
Temp. Service/Feeder 401-600 Amp.
$ 149.00
$
Temp. Service/Feeder 601-1000 Amp.
$168.00
$
Portal to Portal Hourly
$ 96.00
$
Signal Circuit/ Limited Energy -1 & 2 Family Dwelling
$ 64.00
$
Manufactured Home Connection
$ 120.00
$
Renewable Electrical Energy - 5KVA System or Less
$ 102.00 Z
$ 102.00
Thermostat
$ 56.00
$
Note: $5.00 for each additional T-Stat
NEW CONSTRUCTION ONLY:
First 1300 Square Ft.
$ 120.00
$
Each Additional 500 Square Ft. or Portion of
$ 40.00
$
Each Outbuilding or Detached Garage
$ 74.00
$
Each Swimming Pool or Hot Tub
$ 110.00
$
$ 102.0o Total
Owner as defined by RCW.19.28.261: (1) Owner will
occupy the structure for two years after this electrical permit is finalized. (2) Owner is required
to hire an electrical contractor if above said property is for sale, rent or lease. Permit expires after six months
of last inspection.
After reading the above statement, I hereby certify that I am the owner of the above named property or a licensed electrical contractor. I am making
the electrical installation or alteration in compliance with the electrical laws, N.E.C., RCW. Chapter 19.28, WAC. Chapter 296-46B, The City of Port
Angeles Municipal Code, and Utility Specifications and PAMC 14.05.050 regarding Electrical Permit Applications.
Signature of owner, electrical contractor or electrical administrator: ❑ cash V Check
❑ Credit Card #
X /� r Dated: /0/;3/17 0110112012
SCOPE OF WORK
GENERAL NOTES:
PHOTOVOLTAIC SYSTEM SUMMARY
1 AN INVERTER OR AN AC MODULE IN AN INTERACTIVE PHOTOVOLTAIC SYSTEM SHALL AUTOMATIC ALL DE -ENERGIZE ITS OUTPUT TO THE
CONNECTED ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK UPON LOSS OF VOLTAGE IN THAT SYSTEM AND SHALL REMAIN IN
SYSTEM SIZE DC STC -4 80 KW
THAT STATE UNTIL THE ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK VOLTAGE HAS BEEN RESTORED (NEC 690361)
MODULES (16) ITEK ENERGY IT300-SE SOLAR MODULE
2 ALL EXTERIOR ELECTRICAL METALLIC TUBING(EMT) CONDUIT FITTING SHALL BE RAIN TIGHT THREAD -LESS COMPRESSION TYPE
MODULE MX POWER (P/MAX) 30OW
3 MODULES AND SUPPORT STRUCTURES SHALL BE GROUNDED
4 NAMEPLATES SHALL BE PROVIDED FOR ALL CIRCUITS IN THE SERVICE DISTRIBUTION AND POWER DISTRIBUTION SWITCH BOARDS,
INVERTER (8) APS YC500A-MIW
MICROINVERTER
PANEL BOARDS, DISCONNECTING SWITCHES, TERMINAL CABINETS, ETC ALL NAMEPLATES SHALL BE PERMANENTLY ATTACHED AND BE
OF SUFFICIENT CAPACITY TO WITHSTAND THE WEATHER
ARRAY TILT 22'
5 JUNCTION BOX/COMBINER BOX HAVE TO USE COMPRESSION TYPE STRAIN RELIEF POSITIONED FOR APPROPRIATE WATER RUN OFF
AZIMUTH 120° & 210°
6 CONDUIT RUNS SHALL BE PROVIDED WITH SUFFICIENT WEATHERPROOF PULL BOXES OF JUNCTION BOX/COMBINER BOXES PER
ELECTRICAL INFORMATION
APPROPRIATE NEC REQUIREMENTS
COUNTY CLALLAM
7SEE PROVIDED CUT SHEETS FOR ADDITIONAL EQUIPMENT SPECIFICATIONS
UTILITY COMPANY PORT ANGELES
8 WIRING MATERIALS SHALL BE SUITABLE FOR THE SUN EXPOSURE AND WET LOCATIONS FIELD APPLIED PROTECTIVE COATINGS ARE
MAIN SERVICE AMPERAGE 200A
NOT ACCEPTABLE
9 JUNCTION, PULL AND OUTLET BOXES LOCATED BEHIND MODULES SHALL BE SO INSTALLED THAT THE WIRING CONTAINED IN THEM CAN
BUILDING INFORMATION ONE STORY HOUSE
BE RENDERED ACCESSIBLE DIRECTLY OR BY DISPLACEMENT OF MODULE(S) SECURED BY REMOVABLE FASTENERS AND CONNECTED
ROOF COMPOSITE SHINGLEBY
A FLEXIBLE WIRING SYSTEM (NEC 690 34)
NUMBER OF LAYERS 01
10 IN AN UNDERGROUND PHOTOVOLTAIC SYSTEM, THE POWER SOURCE SHALL BE LABELED WITH THE FOLLOWING WARNING AT EACH
ANNUAL AVERAGE WIND SPEED 110 MPH
JUNCTION BOX, COMBINER BOX, DISCONNECT AND DEVICE WHERE THE UNGROUNDED CIRCUITS MAYBE EXPOSED DURING SERVICE "
GROUND SNOW LOAD N/A
WARNING - ELECTRIC SHOCK HAZARD THE CURRENT CIRCUIT CONDUCTORS OF THIS PHOTOVOLTAIC POWER SYSTEM ARE
UNGROUNDED BUT MAY BE ENERGIZED WITH THE RESPECT TO GROUND DUE TO LEAKAGE PATHS AND/OR GROUND FAULTS "(NEC
690 35(F))
CODE SUM MARY
11 ALL PHOTOVOLTAIC MODULES AND ASSOCIATED EQUIPMENT AND WIRING MATERIAL SHALL BE PROTECTED FROM ANY PHYSICAL
DAMAGE
2015 WASHINGTON STATE BUILDING CODE (2015 IBC)
12 ALL ELECTRICAL DEVICES AND UTILIZATION EQUIPMENT SHALL BE LISTED BY AN APPROVED TESTING AGENCY
2015 WASHINGTON STATE ENERGY CODE (20151ECC)
13 OUTDOOR EQUIPMENT SHALL BE AT LEAST NEMA 3R RATED
2015 WASHINGTON STATE RESIDENTIAL CODE
14 ALL SPECIFIED WIRING IS BASED ON THE USE OF COPPER
(2015 1NTERNATIONAL RESIDENTIAL CODE WASHINGTON
15 CONTRACTOR SHALL OBTAIN ELECTRICAL PERMITS AND SHALL COORDINATE ALL INSPECTION, COMMISSIONING AND ACCEPTANCE
AMENDMENTS 2014 WAC51-51-2300 SECTION M2302)
WITH THE CLIENT, UTILITY CO AND CITY INSPECTORS AS NEEDED
2017 WAC 296-46B (2017 NEC)
18 DRAWINGS ARE DIAGRAMMATIC ONLY, ROUTING OF RACEWAYS SHALL BE AT THE OPTION OF THE CONTRACTOR UNLESS OTHERWISE
2015 WASHINGTON STATE MECHANICAL CODE(2015 UMC )
NOTED AND SHALL BE COORDINATED WITH OTHER TRADE
2015 WASHINGTON STATE PLUMBING CODE (2015 UPC)
17 IF DISTANCES OF CABLE RUNS ARE DIFFERENT THAN SHOWN, THE CONTRACTOR SHALL NOTIFY ELECTRICAL ENGINEER TO VALIDATE
2015 WASHINGTON STATE FIRE CODE (20151FC)THE
WIRE SIZE FINAL DRAWINGS WILL BE RED -LINED AND UPDATED AS APPROPRIATE
18 WHENEVER A DISCREPANCY IN QUANTITY OF EQUIPMENT, ARISES ON THE DRAWINGS OR SPECIFICATIONS, THE CONTRACTOR SHALL
BE RESPONSIBLE FOR PROVIDING AND INSTALLING ALL MATERIAL AND SERVICES REQUIRED BY THE STRICTEST CONDITIONS NOTED
SHEET
ON THE ECIFI TIONS TO ENDURE COMPLETE COMPLIANCE AND LONGEVITY OF THE OPERABLE SYSTEM
P
INDEX
D BY THE ARCHITECT ER
PV -0 COVER SHEET
19 ALL BROCHURES, OPERATION MANUALS, CATALOGS, SHOP DRAWINGS, ETC SHALL BE HANDED OVER TO THE OWNER'S
PV -1 PLOT PLAN WITH ROOF PLANS
REPRESENTATIVE AT THE COMPLETION OR WORK
20 ALL WIRING CONCEALED IN WALL AND CEILING SPACES SHALL BE IN METAL CONDUIT
PV -2 ROOF PLAN WITH MODULES
21 THE SEISMIC BRACING AND ANCHORAGE OF ELECTRICAL CONDUITS SHALL BE IN ACCORDANCE WITH THE "SMACNA"-GUIDLINES FOR
PV- 3 ATTACHMENT DETAIL
SEISMIC RESTRAINS OF MECHANICAL SYSTEMS AND PLUMING PIPING SYSTEMS
PV -4 ELECTRICAL LINE DIAGRAM
22 ALL OF THE LISTED SYSTEMS REQUIRED THAT THE SEISMIC LATERAL FORCE F INCLUDING CONSIDERATION OF a"P AND OP BE
PV -5 PLACARDS
PVMANUFACTURER SPEC
DETERMINED AT EACH LEVEL OF THE BUILDING SO THAT BRACE SPACING CAN BE CALCULATED THE DISTRICT STRUCTURAL ENGINEER
SHEET
CAN APPROVE THE SEISMIC LATERAL FORCE DETERMINATION
23 A COPY OF THE CHOSEN BRACING SYSTEM(S) INSTALLATION GUIDE/MANUAL SHALL BE ON THE JOB SITE PRIOR TO STARTING THE
INSTALLING OFHANGERS AND/OR BRACES
24 WHEN INSTALLING DRILLED -IN ANCHORS AND/OR POWDER DRIVEN PINS IN EXISTING NON -PRESTRESSED REINFORCED CONCRETE, USE
CARE AND CAUTION TO AVOID CUTTING OR DAMAGING THE REINFORCED BARS WHEN INSTALLING THEM INTO EXISTING
PRE -STRESSED CONCRETE TENDONS BY USING A NON-DESTRUCTIVE METHOD PRIOR TO INSTALLATION EXERCISE EXTREME CARE
AND CAUTION TO AVOID CUTTING OR DAMAGING THE TENDONS DURING INSTALLATION MAINTAIN A MINIMUM CLEARANCE OF ONE INCH
BETWEEN THE REINFORCEMENT AND THE DRILLED -IN ANCHOR
25 THE WORKING CLEARANCES AROUND THE EXISTING ELECTRICAL EQUIPMENT AS WELL AS THE NEW ELECTRICAL EQUIPMENT WILL BE
MAINTAINED INACCORDANCE WITH NEC 110 2fi
26 CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT (NEC 300 6 01, 310 8 D
27 GROUNDING BUSHINGS ARE REQUIRED AROUND PRE -PUNCHED CONCENTRIC KNOCKOUTS ON THE DC SIDE OF THE SYSTEM (NEC
250 97)
28 THE GROUNDING ELECTRODE CONDUCTOR MUST BE PROTECTED FROM PHYSICAL DAMAGE IF SMALLER THAN #6 COPPER WIRE (NEC
250 64 B)
29 GROUNDING ELECTRODE CONDUCTOR WILL BE CONTINUOUS, EXCEPT FOR SPLICES OR JOINTS AT BUSBARS WITHIN LISTED
EQUIPMENT (NEC 250 64 C)
30RACEWAY FOR GROUNDING ELECTRODE CONDUCTOR SHALL BE BONDED AT EACH END (NEC 25064 (E)
31 WHERE ALL TERMINALS OF THE DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, A SIGN WILL BE PROVIDED
WARNING OF THE HAZARD PER NEC 69017 34 EACH UNGROUNDED CONDUCTOR OF THE MULT-IWIRE BRANCH CIRCUIT WILL BE
IDENTIFIED PER PHASE AND SYSTEM PER NEC210 5
32 CIRCUITS OVER 250V TO GROUND SHALL COMPLY WITH NEC250 97 8 250 92 (B) & LAMC 93 250 97
33 DC CONDUCTORS EITHER DO NOT ENTER THE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR ENCLOSURES TO THE FIRST
ACCESSIBLE DC DISCONNECTING MEANS PER NEC 690 31 (E), LAMC 93690 31 (E)
34 ALL METALLIC FRAME RAILS AND OTHER CURRENT CARRYING METALLIC COMPONENTS (CONDUIT, JUNCTION 8 PULL BOXES, RACEWAY,
ETC) SHALL BE SOLIDLY GROUNDED PER THE MANUFACTURER'S INSTALLATION INSTRUCTIONS LAMC 93 690 110 3 & 93 110 3(B)
35 SCREWS, NUTS, BOLTS & WASHERS THAT ATTACH EQUIPMENT GROUNDING LUGS SHALL BE STAINLESS STEEL LAMC 93 110 3(B)
36 NO PIPING, DUCTS OR EQUIPMENT FOREIGN TO ELECTRICAL EQUIPMENT SHALL BE PERMITTED TO BE LOCATED WITHIN THE
DEDICATED SPACE ABOVE THE ELECTRICAL EQUIPMENT
37 ALL FIELD INSTALLED JUNCTION, PULL AND OUTLET BOXED LOCATED BEHIND MODULES OR PANELS SHALL BE ACCESSIBLE DIRECTLY
OR BY DISPLACEMENT OF A MODULE (S) OR PANEL (S) SECURED BY REMOVABLE FASTENERS
38 REMOVAL OF A DWP-INTERACTIVE INVERTER OR OTHER EQUIPMENT SHALL NOT DISCONNECT THE BONDING CONNECTION BETWEEN
THE GROUNDING ELECTRODE CONDUCTOR AND THE PHOTOVOLTAIC SOURCE AND/OR OUTPUT CIRCUIT GROUNDED CONDUCTOR
39 THE ROOF MOUNTED PHOTOVOLTAIC MODULES, PANELS, OR SOLAR VOLTAIC ROLL ROOFING MATERIAL SHALL HAVE THE SAME OR
BETTER LISTED FIRE -RESISTANCE RATING THAN THE BUILDING ROOF -COVERING MATERIAL
40 ALL ROOF MOUNTED CONDUIT WILL BE A MINIMUM 6" OFF THE ROOF SURFACE
PV -0 I SCALE: NTS
2 VICINITY MAP
PV -0 SCALE. NTS
��
Smart Energy Today Inc:"
SOLAR
1001 Cooper Point Rd SW,
Suite 140-290
Olympia, WA 98502
Phone 888-405-8689
Fax 855-350-9430
support@smarten ergytoday net
REVISIONS
DESCRIPTION I GATE REV
INITIAL 11033-1017 01
I
I
Signature with Seal
PROJECT NAME 8 ADDRESS
SHEET NAME
COVER SHEET
SHEET SIZL
ANSI B
11" X 17"
SHEET NUMBER
PV -0
0 ROOF ACCESS POINT SHALL BE LOCATED IN AREAS THAT DO NOT
REQUIRE THE PLACEMENT OF GROUND LADDERS OVER OPENINGS
SUCH AS WINDOWS OR DOORS, AND LOCATED AT STRONG POINTS
OF BUILDING CONSTRUCTION IN LOCATIONS WHERE THE ACCESS
POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH
AS TREE LIMBS, WIRES OR SIGNS49,
ROOF #1
(12) iTEK ENERGY iT300-SE SOLAR MODULE
(6) APS YC50OA-MIW INVERTER
'EVERY 2 MODULES WITH 1 MICRO INVERTER
1 PLOT PLAN WITH ROOF PLAN
PV -1 SCALE. 1116" = 1'-0"
O
�O
1I
ROOF #2
(4) iTEK ENERGY iT300-SE SOLAR MODULE
(2) APS YC50OA-MIW INVERTER
`EVERY 2 MODULES WITH 1 MICRO INVERTER
vl
CO
(E) MAIN SERVICE PANEL (INSIDE)
Smart Energy Today Inc:"'
■ SgLAR
t '
1001 Cooper Point Rd SW,
Suite140-290
Olympia, WA 98602
Phone 888-405-8689
Fax 855-350-9430
support® smarten e rgytoday net
REVISIONS
DESCRIPTION DATE REV
INITIAL 10-2320 01
Signature with Seal
PROJECT NAME 8 ADDRESS
SHEET NAME
PLOT PLAN &
ROOF PLAN
SHEET SIZE
ANSI B
11" X 17"
SHEET NUMBER
PV -1
MODULE TYPE, DIMENSIONS & WEIGHT
NUMBER OF MODULES = 16 MODULES
MODULE TYPE = iTEK ENERGY iT300-SE SOLAR MODULE
MODULE WEIGHT = 43 LBS / 19.5 KG.
MODULE DIMENSIONS = 65.94'k 39.41" = 18 05 SF
UNIT WEIGHT OF ARRAY = 2.38 PSF
ROOF DESCRIPTION
IROOF TYPE
COMPOSITE SHINGLE
]ROOF LAYER
1 LAYER
IRAFTER FRAMING
2x11 ]
ROOF
ROOF TILT
AZIMUTH
#1 22'
210'
#2 I 22' I 120'
ARRAY AREA
ARRAY ROOF ROOF
ROOF AREA AREA AREA COVERED
MODULES
(Sq. Ft ) (Sq. Ft.) BY ARRAY (%)
1 #1 12 2166 2899 74.72 1
1 #2 4 722 2675 2699
MOUNTING CALCULATIONS
A MOUNTING SYSTEM AND MANUFACTURER SPIDER RAX MOUNTING
] B TOTAL WEIGHT OF MODULES
783,00
LBS I
I MODULE WEIGHT X NUMBER OF MODULES 43 X 16 MODULES
68800
LBS
I CLAMPS 25 LBS X 38 POINTS
9500
C TOTAL NUMBER OF ATTACHMENTS POINTS
38
D WEIGHT PER ATTACHMENT POINT(B/C) -NOT EXCEED 45 LBS
2061 1 LBS
lMAXIMUM SPACING BETWEEN POINTS ON A RAFTER SPACING IS 24" ON
E
4 0
RAIL CENTER
F TOTAL SURFACE AREA OF PV MODULES 1805 SOFT X 16 MODULES
28880
SO FT
G DISTRIBUTED WEIGHT OF PV MODULE ON 78300 LBS/ 28880 SO FT
ROOF (e/F)
271
PSF
IS+
r
r � 2Or o
n •7n
h
77"
ROOF #1 J
(12) ITEK ENERGY IT300-SE SOLAR MODULE ria,y
(6) APS YC50OA-MIW INVERTER '9t4ir
'EVERY 2 MODULES WITH 1 MICRO INVERTER
(E) MAIN SERVICE PANEL (INSIDE)
(E) UTILITY METER
(N) FUSED AC DISCONNECT
LEGEND (N) PV PRODUCTION METER
(N) SOLAR AC COMBINER PANEL
JB -JUNCTION BOX
IA,PI AC COMBINER PANEL
ACD -AC DISCONNECT
PM -PRODUCTION METER
UM - UTILITY METER
MSP - MAIN SERVICE PANEL
O ❑ - VENT, ATTIC FAN (ROOF OBSTRUCTION)
--- -CONDUIT
,�39.41"I,� eq
ITEK ENERGY �4
IT300-SE SOLAR
MODULESIlk-
D
Vl/ �
6'
SFJ F r�ST
s, �otiT r
r
h ti
O4�ry�'R
� OH
ROOF #2
(4) ITEK ENERGY iT300-SE SOLAR MODULE
(2) APS YC50OA-MIW INVERTER
'EVERY 2 MODULES WITH 1 MICRO INVERTER
(N) JUNCTION BOX
(N) 3/4" PVC CONDUIT RUN
1ROOF PLAN & MODULES
PV -2 SCALE 118" = V-0"
1
Shirai Energy Today Ino.`"
SOLAR
1001 CooperPoint Rd SW,
Suite 140-290
Olympia, WA 98502
Phone 868-405-8689
Fax 855-350-9430
support@smadenergytoday net
] REVISIONS
DESCRIPTION I GATE REV
IA
INITL ` 10 :3301] 41
] I
I I
Signature with Seal
PROJECT NAME 8 ADDRESS
W
Q t0 M
M �
to �'
O =av
C� LU M
b LLS
C Lu
In 0
Z Z
Q QO
U �a
0
D_
SHEET NAME
ROOF PLAN &
MODULES
SHEET SIZE
ANSI B
11" X 17"
SHEET NUMBER
PV -2
1 I ATTACHMENT DETAIL
PV -3 SCALE. V = V-0"
3/8" X 3" HEX BOLT WITH 3/8"
SERRATED FLANGE NUT WITH
3/8" STAR WASHERS
(STAINLESS STEEL)
TOP CLAMP
BOTTOM CLAMP
3/8" X 1" HEX BOLT 3/8"
SERRATED FLANGE NUT
WITH 3/8" STAR WASHERS
(STAINLESS STEEL)
ALUMINUM L -FEET
3/8" X 3/4" HEX BOLT 3/8"
SERRATED FLANGE NUT
WITH 3/8" STAR WASHERS
(STAINLESS STEEL)
BASE PLATE
2 I ATTACHMENT DETAIL (enlarged vie
PV -3 SCALE
PV MODULES
SPIDER RAX BLACK WIDOW
COMPOSITE (ONE RAIL)
FLASHINGS
1/2" PLYWOOD
"' USE A CORDLESS IMPACT WRENCH FITTED
WITH A 1/4" SOCKET TO SECURE THE MOUNT
TO THE ROOF DECK USING' (STAINLESS STEEL
6 X 1-1/4") SCREWS INCLUDED WITH THE BLACK
WIDOW MOUNT TORQUE ALL SCREWS TO 14
FT -LBS.
. " NOTE.
WASHINGTON 6 SCREWS
CALIFORNIA 5 SCREWS
FLORIDA 8SCREWS
HAWAII 8 SCREWS
TEXAS. 6 SCREWS
I
Smit Energy Today Inc. "
SOLAR
1001 Cooper Point Rd SW,
Suite 140-290
Olympm, WA 98002
Phone 888-405-8689
Fax 855-350-9430
support@smartenergytoday net
REVISIONS
DESCRIRTION I DATE REV
INITIAL 1013-201] 01
Signature with Seal
PROJECT NAME 8 ADDRESS
Q
c
Q 4p M
C O
Q
cn
2 I=-3CF
W M
/J
g �Qz
Z Z
Q QO
U �a
O
a
SHEET NAME
ATTACHMENT
DETAIL
SHEET SIZE
ANSI B
11" X 17"
SHEET NUMBER
PV -3
a
(16) ITEK ENERGY IT300-SE SOLAR MODULE
(i) STRING OF 12 MODULES
(1) STRING OF 4 MODULES
CONNECTED IN SERIES PER STRING
SYSTEM SIZE - 16 x ITEK 30OW = 4 8OkW
WIRE
WIRE
WIRE
TAG #
CONDUIT
CITY
GAUGE:
1
OPEN AIR
4
#12
O2
3/4" PVC
4
#10
OCP:
3/4" PVC
3
#10
O3/4"
PVC
3
#6
SOLAR MODULE SPECIFICATIONS
MANUFACTURER / MODEL #
ITEK ENERGY iT300-SE
VMP
32.9V
IMP
9A
VOC
398V
ISC
9.7A
MODULE DIMENSION
65 94"L x 39.41"W x 1.97"D (In Inch)
MODULE TEMPERATURE
COEFFICIENT OF Vac
029%/°C
PHOTOVOLTAICMICRO-INVERTERS
EQUIPPED WITH AUTOMATIC, RAPID SHUTDOWN
IAW NEC 690 56 (C)
MICROINVERTERS WITH 12 MODULES
BRANCH CIRCUIT 1
I����O��OI 111111/��OI
MICROINVERTERS WITH 4 MOD
APE YC -500A -j
-4_CIRCUIT
ELECTRICAL LINE DIAGRAM
PV -4 SCALE:NTS
MICRO -INVERTER SPECIFICATIONS
TEMP
WIRE
I TEMP
CONDUIT
WIRE
TERMINAL
INVERTER
STRING GRND GRND WIRE
WIRE TYPE
RATING:
AMP
I DE -RATE:
RATED OUTPU POWER
FILL:
OCP:
75'C RATING:
CITY:
NOC: NEC:
AMPS
SIZE
TYPE
47'
NUMBER OF CURRENT
JUNCTION BOX PV SOLAR COMBINER 3 -WIRE, 125A MAXIMUM, t00A
240V, 60AMP FUSED
(E) MAIN BREAKER TO
PANEL 100A, 240V CONTINUOUS
NEMA 3R, 600V
NEMA 3R, UL LISTED
HOUSE 240 V. N/A
TRUNK CABLE
90°C
30
X 1.04
X
0.80
= 24.96A
25
6
x 208 x 1.25 = 15.6A
#8
THHN-2
THHN-2
90°C
40
X .82
X
0.80
= 26.24A
35
6
x 2.08 x 1.25 = 15.6A
#8
THHN-2
THHN-2
90°C
40
X 1.04
X
1
= 41.60A
35
8
x 2.08 x 1.25 = 20.8A
#8
THHN-2
THHN-2
90°C
75
X 1.04
X
1
= 78.00A
65
8
x 2.06 x 1.25 = 20.8A
#8
THHN-2
MICRO -INVERTER SPECIFICATIONS
AMBIENT TEMPERATURE SPECS
LINE SIDE TAP
MANUFACTURER /MODEL #
APS YC -500A MICRO -INVERTER
RECORD LOW TEMP
ELECTRICAL SYSTEM VIA LINE SIDE TAP, LOAD
-6•
NOMINAL OUTPUT CURRENT
2 08 AMP
AMBIENT TEMP (HIGH TEMP 2%)
(E)MAIN SERVICE
25'
RATED OUTPU POWER
240 VAC
CONDUIT HEIGHT
AC FUSED
0.5"
PV PRODUCTION METER
ROOF TOP TEMP
47'
NUMBER OF CURRENT
JUNCTION BOX PV SOLAR COMBINER 3 -WIRE, 125A MAXIMUM, t00A
PERCENT OF CARRYING CONDUCTORS IN TO UTILITY GRID
VALUES EMT a L2N
BO 4-6 BI-DIRECTIONAL UTILITY METER
70 7-9 1 -PHASE, 3-W 12OV/240V
50 10-20 METER NO 130944653 M
30AMP FUSES �7
I 20A J
Li
L2 I LINE LOAAD �� '
NI
15q -
L1
L2
=[N -I -- J 3 3 4
DEC
GROUNDING
ELECTRODE SYSTEM
1 2
SERVICE INFO
UTILITY PROVIDER: PORTANGELES
MAIN SERVICE VOLTAGE:
UTILITY METER BRAND.LANDIS-GYR
METER FREQUENCY FM2S 60HZ1240V
LINE SIDE TAP
CONNECT NEW SOLAR CIRCUITTO EXISTING
MAIN SERVICE PANEL:
200A
ELECTRICAL SYSTEM VIA LINE SIDE TAP, LOAD
N/A
�F
SIDE OF NET METER AND SUPPLY SIDE OFI+
SERVICE FEED SOURCE:
(E)MAIN SERVICE
MAIN SERVICE PANEL IAW 70512(A1, 23082(8),
69013(() a 69015
AC DISCONNECT
VISIBLE LOCKABLE
1 PANEL, 200A RATED,
240V
AC FUSED
E /
,1 i
PV PRODUCTION METER
DISCONNECT WITH
240V AC I60HZ, 1 -PHASE,
EXTERIOR HANDLE,
JUNCTION BOX PV SOLAR COMBINER 3 -WIRE, 125A MAXIMUM, t00A
240V, 60AMP FUSED
(E) MAIN BREAKER TO
PANEL 100A, 240V CONTINUOUS
NEMA 3R, 600V
NEMA 3R, UL LISTED
HOUSE 240 V. N/A
30AMP FUSES �7
I 20A J
Li
L2 I LINE LOAAD �� '
NI
15q -
L1
L2
=[N -I -- J 3 3 4
DEC
GROUNDING
ELECTRODE SYSTEM
1 2
SERVICE INFO
UTILITY PROVIDER: PORTANGELES
MAIN SERVICE VOLTAGE:
240V
MAIN PANEL BRAND:
FEDERAL PACIFIC
MAIN SERVICE PANEL:
200A
MAIN CIRCUIT BREAKER RATING:
N/A
MAIN SERVICE LOCATION:
SOTH
SERVICE FEED SOURCE:
OVERHAED
Smart Energy Today Inc:"
SOLAR
1001 Cooper Point Rd SW,
Suite 140-290
Olympia, WA 98502
Phone 888-405-8689
Fax 855-350-9430
support® smarten argyto6ay net
REVISIONS
DESCRIPTION OATS REV
INITIAL 10-233017 01
Signature with Seal
PROJECT NAME 8 ADDRESS
vJ
Qt0fh
C M
L H coo M
uJ rn
Q
M
HH
> W
C J
LU
L z O
Z
Q Q =
EL
U Of
O
EL
SHEET NAME
ELECTRICAL LINE
DIAGRAM
SHEET SIZE
ANSI B
11" X 17"
SHEET NUMBER
PV -4
•` I IIFVIu FFUU—Smart Energy Today Inc."
POWER SOURCE
CAUTION SOLAR
LABEL LOCATION
JUNCTION BOX
(PER CODE NEC 690 31(G)(3)(4)
TURN RAPID SHUTDOWN
SWITCH TO THE
ADHESIVE FASTENED SIGNS
ill aim
"OFF" POSITION TO
WHERE IT IS INSTALLED
SHUT DOWN PV SYSTEM
AND REDUCE
• WHERE REQUIRED ELSEWHERE IN THIS CODE, ALL FIELD
���•
SHOCK HAZARD
POINT OF INTERCONNECTION, SOLAR BREAKER
�_�•���tii�i���
IN THE ARRAY
MARKING].
LABEL LOCATION
• ADHESIVE FASTENED SIGNS MAY BE ACCEPTABLE IF
•
POINT OF INTERCONNECTION, SOLAR BREAKER(S),
RESISTANT [IFC 60511 1 31
PV COMBINER
LABEL LOCATION
POINT OF INTERCONNECTION, SUPPLY SIDE TAP (IF APPLICABLE)
(PER CODE NEC 69013 (B))
AC DISCONNECT, POINT OF INTERCONNECTION
(PER CODE NEC 690 56(C)(1)(a), IFC 60511 31(1)
I
WARNING
PHOTOVOLTAIC ADISCONNECT
• • • .
TURN OFF PHOTOVOLTAIC
NOMINAL OPERATING , VOLTAGE240
VAC
AC DISCONNECT PRIOR TO
WORKING INSIDE PANEL
LABEL LOCATION
AC DISCONNECT, POINT OF INTERCONNECTION
LABEL LOCATION
(PER CODE NEC 69054)
POINT OF INTERCONNECTION,
SERVICE PANEL, PV COMBINER
(PER CODE NEC 110 27 (C))
' WARNING
ELECTRIC SHOCK HAZARD
AWARNING DUAL POWER SOURCE
TERMINALS ON BOTH LINE AND
LOAD SIDES MAY BE ENERGIZED
LABEL LOCATION
IN THE OPEN POSITION
POINT OF INTERCONNECTION
(PER CODE NEC 705 12(D)(3) NEC 690 59)
LABEL LOCATION
NET METER, PRODUCTION METER
AC DISCONNECT, POINT OF INTERCONNECTION
(PER AHJ, UTILITY OPERATIONS)
PER CODE NEC 69013(B)
'16JI•
LABEL LOCATION
PRODUCTION METER
1\ =1 I =114:1111111
LABEL LOCATION LABEL LOCATION
POINT OF INTERCONNECTION, SOLAR BREAKER (NET METER)
PER CODE NEC 705 12(B)(2)(c) PER CODE NEC 70512(D)(3) NEC 690 59
POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE
FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN
AT: ® MAIN SERVICE PANEL 8 UTILITY METER +
PRODUCTION METER
FUSED AC DISCONNECT
SOLAR AC COMBINER
W 6TH ST
(E) MAIN SERVICE PANEL (INSIDE)
(E) UTILITY METER
(N) FUSED AC DISCONNECT
V �
Vt
(N) PV SOLAR COMBINER
(N) PV PRODUCTION METER
ELECTRICAL NOTES
1.) ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND
LABELED FOR ITS APPLICATION
2.) ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V
AND 90 DEGREE C WET ENVIRONMENT
3.) WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS
SHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE AS
POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY
4.) WORKING CLEARANCES AROUND ALL NEW AND EXISTING
ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110 26
5.) DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF
SYSTEMS. CONTRACTOR SHALL FURNISH ALL NECESSARY
OUTLETS, SUPPORTS, FITTINGS AND ACCESSORIES TO FULFILL
APPLICABLE CODES AND STANDARDS.
6.) WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS
ARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEM
ACCORDINGLY.
7.) ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY
LABELED AND READILY VISIBLE.
8.) MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN
MODULE FRAME AND MODULE SUPPORT RAIL, PER THE
GROUNDING CLIP MANUFACTURER'S INSTRUCTION.
9) MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS
COPPER G.E C VIA WEEB LUG OR ILSCO GBL-4DBT LAY -IN LUG.
10) THE POLARITY OF THE GROUNDED CONDUCTORS IS NEGATIVE
1001 Cooper Point Rd SW,
Suite 140-290
Olympia, WA M2
Phone. 888405-8889
Fax 855-350-9430
support(Memartenergytoday net
REVISIONS
OESCRIPTION DATE REV
INITIAL 10-33SOiT Ot
Signature with Seal
PROJECT NAME 6 ADDRESS
Q
0
Ca Mo
G F C c h
0 r
Q
M
F-
H (0 LU
N J
�Qz
�QO
U �a
O
a
SHEET NAME
PLACARDS
SHEET SIZE
ANSI B
11'r X 17"
SHEET NUMBER
PV -5
ADHESIVE FASTENED SIGNS
• THE LABEL SHALL BE SUITABLE FOR THE ENVIRONMENT
WHERE IT IS INSTALLED
• WHERE REQUIRED ELSEWHERE IN THIS CODE, ALL FIELD
LABEL LOCATION
APPLIED LABELS, WARNINGS, AND MARKING SHOULD
POINT OF INTERCONNECTION, SOLAR BREAKER
COMPLY WITH ANSI Z535 4 [NEC 110 21(B) FIELD
PER CODE NEC 70512(B)(2)(c)
MARKING].
• ADHESIVE FASTENED SIGNS MAY BE ACCEPTABLE IF
•
PROPERLY ADHERED VINYL SIGNS SHALL BE WEATHER
RESISTANT [IFC 60511 1 31
LABEL LOCATION
POINT OF INTERCONNECTION, SUPPLY SIDE TAP (IF APPLICABLE)
PER CODE NEC 705 12(6)(2)(c)
POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE
FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN
AT: ® MAIN SERVICE PANEL 8 UTILITY METER +
PRODUCTION METER
FUSED AC DISCONNECT
SOLAR AC COMBINER
W 6TH ST
(E) MAIN SERVICE PANEL (INSIDE)
(E) UTILITY METER
(N) FUSED AC DISCONNECT
V �
Vt
(N) PV SOLAR COMBINER
(N) PV PRODUCTION METER
ELECTRICAL NOTES
1.) ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND
LABELED FOR ITS APPLICATION
2.) ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V
AND 90 DEGREE C WET ENVIRONMENT
3.) WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS
SHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE AS
POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY
4.) WORKING CLEARANCES AROUND ALL NEW AND EXISTING
ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110 26
5.) DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF
SYSTEMS. CONTRACTOR SHALL FURNISH ALL NECESSARY
OUTLETS, SUPPORTS, FITTINGS AND ACCESSORIES TO FULFILL
APPLICABLE CODES AND STANDARDS.
6.) WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS
ARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEM
ACCORDINGLY.
7.) ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY
LABELED AND READILY VISIBLE.
8.) MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN
MODULE FRAME AND MODULE SUPPORT RAIL, PER THE
GROUNDING CLIP MANUFACTURER'S INSTRUCTION.
9) MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS
COPPER G.E C VIA WEEB LUG OR ILSCO GBL-4DBT LAY -IN LUG.
10) THE POLARITY OF THE GROUNDED CONDUCTORS IS NEGATIVE
1001 Cooper Point Rd SW,
Suite 140-290
Olympia, WA M2
Phone. 888405-8889
Fax 855-350-9430
support(Memartenergytoday net
REVISIONS
OESCRIPTION DATE REV
INITIAL 10-33SOiT Ot
Signature with Seal
PROJECT NAME 6 ADDRESS
Q
0
Ca Mo
G F C c h
0 r
Q
M
F-
H (0 LU
N J
�Qz
�QO
U �a
O
a
SHEET NAME
PLACARDS
SHEET SIZE
ANSI B
11'r X 17"
SHEET NUMBER
PV -5
Lauumy tnul exceeu performance expecTaTlons
at an affordable price.
Connectwith us:
www.itekenergy.com I info®itekenergy.com
=l .
k ek rsTk
MA OMIN AMEft^CA Multi
ao A t and TAA M
Sao, P'IroJecldCompllaM 1703
itek S
E N E R G Y
Building Solar I Powering The Future
itek LE Solar Module
CM Type •60 high efficlency monocryooline p type calk
High -efficiency monocrystalline silicon
- - •6x10 CeN rnohbi
PERC cells
OCertified
PID -free above and beyond
• Tempered, with low on content
the industry standard
• Am -glare prismatic subsurface texture
Full quality check of every module
ladiii • MUM layeretl
along the production line
• Englne.ed atlhasion la mawmum weather prolecfron
Impact -resistant, anti -glare solar glass
Ramp • High -&-tit conn io—stont on000ed olummum
25 -year power output warranty
VVw
10 -year workmanship warranty
Connectwith us:
www.itekenergy.com I info®itekenergy.com
=l .
k ek rsTk
MA OMIN AMEft^CA Multi
ao A t and TAA M
Sao, P'IroJecldCompllaM 1703
itek S
E N E R G Y
Building Solar I Powering The Future
itek LE Solar Module
CM Type •60 high efficlency monocryooline p type calk
Op. -Ii Tenp.olwe
- - •6x10 CeN rnohbi
MabWnlSpt.n Vdlsp
Solt, Gk. • Ullm-ciom Hflcfiv freafinent
Derma lood (M I
• Tempered, with low on content
Magnum loop (UL 170)
• Am -glare prismatic subsurface texture
Magnum Wind Loon
ladiii • MUM layeretl
M-SM.WNR."
• Englne.ed atlhasion la mawmum weather prolecfron
Mas Re9.w Cun.B
Ramp • High -&-tit conn io—stont on000ed olummum
Terrlpetdile(WM
• Compafibte w th st hdord ru d g...... m odating both
top down
clamps and bottom tong. mounting
Tanperwmco~ot Vac
CdA. • 42" 90'C I2 WG PV wire
TarnpwMue Ca/Iltlert Of 6
Jusoean las • 3 bypass diodes • 1000 VDC MC4 connecfon
T.Eip.dale CoelRdeMor V_
G-.dkV • Certified for wMey F Ironies WEER- grountling cNps
• Eight standard grounding locations per mWule for
reduced ground wk.lersglh
0L Lwv UL 17M
Ile RaRq Tpe2
PID Fee 500- no
ARRA. MA and TM ct,rprml
MagnAn PpAer-P... Mpl 280 285 290 295
300
Makilurl PbA�Vdlage--M 323 324 326 328
329
MtMriun Posserpp.H-Ir•W 86 8.7 9.8 89
9.0
arses ClNVaMpe-V«m 39.2 393 395 39.7
39.8
Je 0"ou lOIneM-taut 93 94 95 96
97
..dAeW it,lY 1670% 1699% 1729% 1759%
1789%
Mormon
1001 mm X 1675mm X 50mm
W -Wo -- 431bs
Op. -Ii Tenp.olwe
40._+WC
MabWnlSpt.n Vdlsp
IWOVDC
Derma lood (M I
Up to 113 lbs/ftp
Magnum loop (UL 170)
551 kg/m2 (5400 Pal
Magnum Wind Loon
113 lbs/h'
M-SM.WNR."
ISA
Mas Re9.w Cun.B
i5A
Terrlpetdile(WM
i,
Terlp.aMe CooNow of P.
0 3,%,_
Tanperwmco~ot Vac
-i'2?%P"
TarnpwMue Ca/Iltlert Of 6
)4A/'i_
T.Eip.dale CoelRdeMor V_
Smart Energy Today Inc."
SOLAR
1001 Cooper Point Rd SW,
Suite 140-290
Olympia, WA 98502
Phone 888-405-8689
Fax 855-350-9430
support@smanenergytoday net
REVISIONS
DESCRIPTION DATE IREV
INITIAL 10.23-20t) I 81
I
I I �
Signature with Seal
PROJECT NAME 8 ADDRESS
U)
e�
Q cp M
M C3
F 'ODD M
F O F
H �W$
J v
�z0
Z
Q Q
U �a
0
a
SHEET NAME
EQUIPMENT
SPECIFICATION
SHEET SIZE
ANSI B
11" X 17"
SHEET NUMBER
PV -6
APsystems
r ALT E N E R G Y P O WE R Leading the Industry in
Solar Microinverter Technology
DIMENSIONS
ea s LSOm'"' Our flagship product, the APsystems YC500A is a grid -tied
microinverter with Intelligent networking and monitoring
systems to ensure maximum efficiency. Highly dependable
1—• L
EB_ _._ and cost effective, the YCSOOA handles up to 310W
i as„�r,ml modules with negligible clipping, delivering 250W AC per
1= module with dual MPPT Half the inverters and half the
installation means real cost savings for residential and
commercial customers.
Smart Energy Today Inc. °
SOLAR
1001 Cooper Point RC SW,
Suite 140-290
, •
APsystemsPhone
.
Olympia, WA 98(92
•
888-405-8689
Fax 855-350-9430
support@$ martenergyto day net
INPUT DATA (DC)
I REVISIONS
Recommended PV Module Power Range (STC)
180-31OW
I DES."PnoN DATE Rev
MPPT Voltage Range
22-45V
NITIAL ,0 23 2017 of
Maximum Input Voltage
55V
Maximum Input Current
12A X 2
OUTPUT DATA (AC)
Signature with Seal
Rated Output Power
50OW
Maximum Output Current
2 OBA'o. 240V 2.4A fm208V
Nominal Output Voltage/Range - 240V
240V/211V-264V*
Nominal Output Voltage/Range - 208V
208V/183V-229V'
Nominal Output Frequency/Range
60H2/ 59.3-60.5H2'
Power Factor
>0.99
Total Harmonic Distortion
<3%
PROJECT NAME & ADDRESS
Maximum Units Per Branch
7 per 20A ,. 240V 6 per 20Aa 208V
EFFICIENCY
Peak Efficiency
95.5%
CEC Weighted Efficiency"
95%
Nominal MPP Tracking Efficiency
99.5%
<
MECHANICAL DATA
(n
Storage Temperature Range
-40°F to +185"F (-40°C to +85aC)
co
Q t0+) O
Operating Temperature Range
-40'F to +149°F (-40°C to +65°C)
1.-:000 (h
Dimensions (WxHxD) Inches
8.75' x 6.5" x 1.1"
V) Q M
O
'�
Dimensions (WxHxD) mm
221mm x 167mm x 29mm
=
Weight
5.5 Itis (2.5kg)
t:0 O
Enclosure Rating
NEMA 6>
LU M
Cooling
Natural Convection - No Fans
C -j
U ZO
FEATURES & COMPLIANCE
Communication
Power line (PLC)
Q Q 2
Warranty
10 years standard, extendable to 25 years
U d
Emissions & Immunity (EMC) Compliance
FCC PART 15, ANSI C634 2003, ICES -003
Q
Safety Class Compliance
UL 1741, CSA C22 2, No 1071-01, NEC2014 69012
(L
Grid Connection Compliance
IEEE 1547
e<,n<anons :�eien to monge wrtnout nou�e <e enw,n w� =re u. n1 t e
ea
- Programmame oer <ustomei and unoty requnemencs
most ,ecen, upaat+found ai www AFrratem. cem
All -V'191 UL approved
"CEC registn,ed 1s Altenergy Power System in<
SHEET NAME
12 115 ,an R,gnls aaserven
EQUIPMENT
SPECIFICATION
SHEET SIZE
i.cu, t ,.-«,,,n n.,• Nt :un,: +nn ;..nice wn 18110 vn,r n,a. ,,, APsYxtrmx
wm *,, APsystems
ANSI B
ALTENERGY POWER
11" X 17"
SHEET NUMBER
PV -7
TOP CLAMP
RAIL
BOTTOM CLAMP
INTEGRATED ILSCO
GROUND LUG -
COMPATIBLE WITH #4, #8,
#8 & #10 BARE AND
STRANDED COPPER WIRE
S HOOK
BASE PLATE
SPIDER -RAX BLACK WIDOW COMPOSITE
RACKING SYSTEM DETAIL (NTS)
Smart Energy Today Inc."'
SOLAR
1001 Cooper Point Rd SW,
Sults 140-290
Olympia, WA 98502
Phone 888-405-8689
Fax 855-350-9430
support@smartenergytoday net
REVISIONS
DESCRIPTION I REV
INITIAL 10-23.201] 01
Signature with Seal
PROJECT NAME 8 ADDRESS
Q rD M
M (0
� � r
Q
M
_ o
>- 3W
J
W
Ur z
�z
o
Q Q
U F- (L
0
Q.
FSHEET NAME
QUIPMENT
ECIFICATION
SHEET SIZE
ANSI B e
11" X 17
SHEET NUMBER
PV -8
Smart Energy Today Inc.
SOLAR
SAGroup
((p f"
Grow
1001 Cooper Point RJSW,
Su to 140-290
III
Olympia, WA 91
Phone 888-405-8689
Fax 855-350-9430
Certificate of Compliance
Certificate: 2763733 Master Contract: 262043
support@smartenergytoday net
REVISIONS
Project: 2763733 Date Issued: June 4, 2015 I
DESCRIPTION DATE REV
Certifleate: 2763733 Master Contract: 262043
j
INITIAL mo -v -eon o+
Project: 2763733 Date Issued: lune 4, 2015
Devices, Clamping/Retention Devices, and Ground Lugs
Issued to: Spider RAX Inc
signature with seal
for use with Flat -Plate Photovoltaic Modules and Panels.
38713 Tierra Subida, 200-622
Palmdale, CA 93551
-
USA
Attention: Todd Ayers
[
f
The products listed below are eligible to bear theCSA
Mark shown with adjacent indicators V and rUJ r for
PROJECT NAME 8 ADDRESS
Canada and US or with adjacent indicator "US"for
US only or without either indicator for Canada only.
a
I to
® 7'�anaGctionjw-
� r�
Stoj-scwijev r,
rCOi
Q o
GCIP
US Issued by: Tatjana Galonja-Stcjsa vljevic
F- op
pt`?
c
PRODUCTS
O
CLASS531302 - POWF.RSUPPLIES-PHOTOVOLTAICS--[IV Racking
N
> LU
CLASS 5313 82 -POWER SUPPLIES- PHOTOVOLTAICS - PV Racking and clamping
} J
systems -Certified to US Standards
p W tyj
U Z
PV Racking Systems. models Red Widow, Black Widow, Tarantula and Wolf Spider, suitable for use with
Z O
approved flat -plate photovoltaic modules with maximum size of 1.96 meters by 0.98 meters and a minimum
Q Q =
ltame height of 35 mm and a maximum (tame height of 40inm and it series fuse rating of 20 A.
F- a
0
a
Notes:
The products are approved as a component only and subject to final approval by authorities having jurisdiction.
APPLICABLE, REOUIRE:MENTS
LTR Ali -001-2012 - Photovoltaic Module and Panel Racking Systems.
SHEET NAME
UL Subject 2703 (Issue Number 2) - Outline of Investigation for Mounting Systems, Mounting
EQUIPMENT
SPECIFICATION
SHEET SIZE
ANSI B
2012 i'exe, I
DOD 50'+R,, 201245 22 P.,ae :
11 " X 17"
WD 507 Re, -IIS 22
....___.-._-_._..._.._...,_....___..m.._,......_.�.-.._W_..,,.... _...._._..._ �...._.d...._._SHEET
NUMBER
Pill