HomeMy WebLinkAbout1401 Aurora Ct - Building
CITY OF PORT ANGELES
DEP ARTMENT OF COMMUNITY DEVELOPMENT - BUILDING DNISION
321 EAST 5TH STREET, PORT ANGELES, W A 98362
05-00000964 Date
658940
1401 AURORA CT
T6-30-00-1-0-7800-0007-
LOT 7
RES NEW SFR
11/30/05
Application Number
Application pin number
Property Address
ASSESSOR PARCEL NUMBER:
Tenant nbr, name
Application type description
Subdivision Name
Property Use
Property Zoning . . .
Application valuation
RS9 RESDNTL SINGLE FAMILY
189240
RIJtr1t(!
II/b/o6
Separate Permits are required for electrical work, SEPA, Shoreline, ESA, utilities, private and public improvements. This permit becomes
null and void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned
for a period of 180 days after the work as commenced, or if required inspections have not been requested within 180 days from the last
inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of
laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not
presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construction.
7
/
Owner
Contractor
OLYMPIC LAND DEVELOPMENT INC.
259403 HWY 101
SEQUIM WA 98382
(360) 457-7222
Other struct info
WANT ACTION CONSTRUCTION
P. O. BOX 1425
SEQUIM
(360) 681-3992
TOTAL % LOT COVERAGE
NUMBER OF STORIES
LOT SIZE
TOTAL LOT COVERAGE
NUMBER OF' UNITS
INC.
WA 98382
27.00
1. 00
9008.00
2398.00
1. 00
Permit . . . . .
Additional desc .
Permit pin number
Permit Fee
Issue Date
Expiration Date
BUILDING PERMIT -RESIDENTIAL
63719
1521. 25
11/30/05
5/29/06
Plan Check Fee
Valuation
608.50
189240
Qty Unit Charge Per
Extension
1017.25
504.00
90.00
BASE FEE
5.6000 THOU BL-100,OOl-500K (5.60 PER K)
Permit . . . . .
Additional desc .
Permit pin number
Permit Fee
Issue Date
Expiration Date
ELECTRICAL NEW RESIDENTIAL
63735
36.40
11/30/05
5/29/06
Plan Check Fee
Valuation
.00
o
Qty Unit Charge Per
1.00 36.4000 EC EL-LOW VOLTAGE
Extension
36.40
Permit MECHANICAL PERMIT
Additional desc
Permit pin number 63727
Permit Fee 101. 35 Plan Check Fee .00
Issue Date 11/30/05 Valuation 0
Expiration Date 5/29/06
Qty Unit Charge Per Extension
BASE FEE 47.00
1.00 14.7000 ECH ME- INSTALL 100- FAU 14.70
4.00 7.2500 ECH ME-VENT FAN 29.00
1.00 10.6500 ECH ME-GAS PIPE 1 TO 5 10.65
Permit PLUMBING PERMIT
Additional desc . .
1/- S{)-a5
Date
Signature of Owner (if owner is builder)
tractor or Authorized Agent
T:\Policies\11 02_15 building permit inspection record05. wpd [1/4/2005]
~
,
s:;
$-
'\)l
"
t.,
.\~
~
\...,J
D-Y
_ 0:::--
L~
s:~
~
~
\
Dat~\
BUILDING PERMIT INSPECTION RECORD
CALL 417-4815 FOR BUILDING INSPECTIONS. CALL 417-4735 FOR ELECTRICAL INSPECTIONS.
CALL 417-4807 FOR PUBLIC WORKS UTILITIES
PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLA WFUL TO COVER, INSULA TE OR CONCEAL ANY WORK BEFORE
INSPECTED AND ACCEPTED. POST PERMIT IN A CONSPICUOUS LOCATION.
KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE.
...
INSPECTION TYPE DATE ACCEPTED COMMENTS
.
YES NO
FOUNDATION:
FOOTINGS 't ' ," ,
, -
WALLS .
FOUNDATION DRAINAGE 1 DOWN SPOUTS
PIERS
POST HOLES (POLE BLDGS.)
PLUMBING
UNDER FLOOR 1 SLAB
ROUGH-IN
WATER LINE (METER TO BLDG)
GAS LINE FINAL DATE ACCEPTED BY:
BACK FLOW 1 WATER
AIR SEAL
WALLS
CEILING I
FRAMING
JOISTS / GIRDERS
SHEAR W ALL/HOLD DOWNS
WALLS 1 ROOF 1 CEILING
DRYWALL(INTE~ORBRACEDPANELONLD
T-BAR
INSULATION
SLAB
WALL / FLOOR 1 CEILING I
MECHANICAL
HEAT PUMP 1 FURNACE I DUCTS
GAS LINE
WOOD STOVE I PELLET I CHIMNEY FINAL DATE ACCEPTED BY:
COMMERCIAL HOOD I DUCTS
MANUFACTURED HOMES
FOOTING I SLAB
BLOCKING & HOLD DOWNS
SKIRTING
PLANNING DEPT. SEPARATE PERMIT #'s SEPA:
PARKINGILIGHTING ESA:
LANDSCAPING SHORELINE:
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCYIUSE
RESIDENTIAL DATE YES NO COMMERCIAL DATE ACCEPTED
YES NO
ELECT~CAL - LIGHT DEPT. 417-4735 ELECT~CAL
LIGHT DEPT
CONSTRUCTION R. W.I PWI CONSTRUCTION - R.W.
ENGINEERING 417-4807 PW I ENGINEERING
FIRE 417-4653 FIRE DEPT.
PLANNING DEPT. 417-4750 PLANNING DEPT.
BUILDING 417-4815 BUILDING
T:\Policies\1102_15 building permit inspection record05.wpd [1/412005]
.
- .,
f pORT ~
:aJ'~O~~
~
"-~
~
~-~
CITY OF PORT ANGELES
DEP ARTMENT OF COMMUNITY DEVELOPMENT - BUILDING DIVISION
321 EAST 5TH STREET, PORT ANGELES, WA 98362
Application Number
Application pin number
Permit pin number 63743
Permit Fee 146.00
Issue Date 11/30/05
Expiration Date 5/29/06
05-00000964
658940
Page
Date
2
11/30/05
Plan Check Fee
Valuation
.00
o
Qty Unit Charge Per
BASE FEE
10.00 7.0000 ECH PL- EA.FIXTURE ON ONE TRAP
1.00 7,0000 ECH PL- EA. INSTALL WATER PIPE
1.00 15.0000 ECH PL- EA. BLDG SEWER
1. 00 7.0000 ECH PL- EA.WATER HEATER
Extension
47,00
70,00
7.00
15.00
7.00
Special Notes and Comments
Building address sign shall not be less than 6" & not more
than 12" in height, Numbers colors must contrast with wall
color they are mounted on. (Ord. 14.36.050-E)
When roof gutters are installed, drains will located in dry
wells or piped to approved storm drain location, No
pressurized or pumping to curbs are allowed. An inspection
by Building Department is required prior to backfill.
Address numbers shall be plainly visible from the street,
Address numbers shall be a minimum of six inches high and be
of contrasting color from the background.
All homes in new subdivisions that are outside of the Fire
Department four~minute response area shall be equipped with
residential fire sprinkler systems that comply with the
International Fire Code (IFC) and National Fire Protection
Association (NFPA),
10/25/2005 01:15 PM SROBERDS -- The proposal will result
in a new sfr w/attached garage for total lot coverage of
27%. NO occupancy will be issued until all road and
utility improvements have been installed and approved.
Electrical load calculations and elctrical permits are
required.
Electrical connection fee required of $222.00,
10/19/2005 11:47 AM GMCLAIN ----------------------------
Ditches & 12" culverts will be installed to City Stanards.
See Public Works Engineering for Standards.
Sanitary sewer connection inspection is required by
Public Works prior to back fill of ditch. 24 hour advance
notice is required.
Construct driveway and Sidewalks to City Standards,
No concrete.with exposed, aggregate allowed in the City
road right of way, An inspection by Public Works
Engineering is required prior to prouring concrete.
Other Fees
SEWER SYSTEM DELV CHARGE
STATE SURCHARGE
PW WATER SYSTEM USE FEE
745,00
4.50
1025,00
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 1805.00 1805.00 ,00 .00
Plan Check Total 608.50 608.50 .00 .00
Other Fee Total 1774.50 1774.50 ,00 ,00
Grand Total 4188,00 4188.00 ,00 ,00
Separate Permits are required for electrical work, SEPA, Shoreline, ESA, utilities, private and public improvements, This permit becomes
null and void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned
for a period of 180 days after the work as commenced, or if required inspections have not been requested within 180 days from the last
inspection, I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of
laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not
presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construc~.
L II ~:SO 'd5-
Signature 0 Date Signature of Owner (if owner is builder) Date
T:\Policies\1102_15 building permit inspection record05.wpd [1/4/2005]
BUILDING PERMIT INSPECTION RECORD
.. ..' . , -
CALL 417-4815 FOR BUILDING INSPECTIONS. CALL 417-4735 FOR ELECTRICAL INSPECTIONS.
CALL 417-4807 FOR PUBLIC WORKS UTILITIES
PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLA WFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE
INSPECTED AND ACCEPTED. POST PERMIT IN A CONSPICUOUS LOCATION.
KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE,
~
~
-D
~
+
INSPECTION TYPE DATE ACCEPTED COMMENTS
YES NO
FOUNDATION:
FOOTINGS It. .IC'J-\ 0L{.- ~~ 7'~ lor. UlA.-/
WALLS fa-/i;q () ~ J!fIff
FOUNDATION DRAINAGE 1 DOWN SPOUTS
PIERS
POST HOLES (POLE BLDGS.)
PLUMBING
UNDER FLOOR 1 SLAB ~
ROUGH-IN pltl. I ~c. '1~
WATER LINE (METER TO BLDG) '),7 r I (l(... l 'T JA., ,(bloc DATE ~ ACCEPTED BY:
GAS LINE FINAL
BACK FLOW 1 WATER
AIR SEAL
WALLS ?J7/ /0'(, J"W
CEILING I
FRAMING le;wp. 3/U /b(;. ~
JOISTS 1 GIRDERS
SHEAR W ALL/HOLD DOWNS .
WALLS 1 ROOF 1 CEILING p.v, J 0(" a/{,;
DRYWALL (INTE~OR BRACED PANEL ONL D 7J/U /0(;, T"fA.....-
T-BAR
INSULATION
SLAB .
WALL 1 FLOOR 1 CEILING Q/'? fa, JW I
MECHANICAL
HEAT PUMP 1 FURNACE 1 DUCTS
GAS LINE t/6/X
WOOD STOVE 1 PELLET 1 CHIMNEY FINAL 'DATE ~ ACCEPTED BY:
..
COMMERCIAL HOOD 1 DUCTS
MANUFACTURED HOMES
FOOTING 1 SLAB
BLOCKING & HOLD DOWNS
SKIRTING
PLANNING DEPT. SEPARATE PERMIT #'s SEPA:
PARKING/LIGHTING ESA:
LANDSCAPING SHORELINE:
FINALJNSPECTIONS REQUIRED PRIOR TO OCCUPANCYIUSE
RESIDENTIAL DATE YES NO COMMERCIAL DATE ACCEPTED
YES NO
ELECT~CAL - LIGHT DEPT. 417-4735 ELECT~CAL
LIGHT DEPT
CONSTRUCTION R. W.I PWI CONSTRUCTION - R. W.
ENGINEERING 417-4807 PW 1 ENGINEERING
FIRE 417-4653 FIRE DEPT.
PLANNING DEPT. 417-4750 I I ~ PLANNING DEPT.
BUILDING 417-4815 ell 7;;[,Oh 0VV BUILDING
T:\Policies\1102_15 building ermit ins ction record05. d 1141200rs1
~
t
-
l~
~~
~
p
pe
wp[
~
f';>ORT ""v.
$~O~~~
,.
"'-~
~
~C~
CITY OF PORT ANGELES
PUBLIC WORKS - UTILITIES DIVISION
321 EAST 5TH STREET, PORT ANGELES, WA 98362
Application Number
Application pin number
Property Address
ASSESSOR PARCEL NUMBER:
Tenant nbr, name
Application type description
Subdivision Name
Property Use
Property Zoning . . ,
Application valuation
05-00000964 Date 11/30/05
658940
_1401 AURORA CT
T6-30-00-1-0-7800-0007-
LOT 7
RES NEW SFR
RS9 RESDNTL SINGLE FAMILY
189240
Owner
Contractor
OLYMPIC LAND DEVELOPMENT INC,
259403 HWY 101
SEQUIM WA 98382
(360) 457-7222
Other struct info
WANT ACTION CONSTRUCTION
P. 0, BOX 1425
SEQUIM
(360) 681-3992
TOTAL % LOT COVERAGE
NUMBER OF STORIES
LOT SIZE
TOTAL LOT COVERAGE
NUMBER OF UNITS
INC.
WA 98382
27.00
1.00
9008.00
2398.00
1.00
Permit PUBLIC WORKS RES WATER SERV
Additional desc 3/4" DROP IN WATER METER
Permit pin number 63024
Permit Fee 195,00 Plan Check Fee
Issue Date 11/30/05 Valuation
Expiration Date 5/29/06
,00
189240
Qty Unit Charge Per
1. 00 195.0000 EA PW W/M SFR 3/4"
Extension
195,00
Permit . . . , .
Additional desc .
Permit pin number
Permit Fee
Issue Date
Expiration Date
RIGHT OF WAY
63008
50,00
11/30/05
5/29/06
plan Check Fee
Valuation
,00
189240
Qty Unit Charge Per
1.00 50.0000 ECH RIGHT OF WAY PERMIT
Extension
50.00
Permit . , . . .
Additional desc .
Permit pin number
Permit Fee
Issue Date
Expiration Date
SANITARY SEWER HOOK UP
63016
110,00
11/30/05
5/29/06
Plan Check Fee
Valuation
.00
189240
Qty Unit Charge Per
1.00 110.0000 EA SAN SEWER HOOKUP
Extension
110.00
Special Notes and Comments
Building address sign shall not be less than 6" & not more
than 12" in height. Numbers colors must contrast with wall
color they are mounted on. (Ord. 14.36.050-E)
When roof gutters are installed, drains will located in dry
wells or piped to approved storm drain location. No
Separate Permits are required for electrical work, SEPA, Shoreline, ESA, utilities, private and public improvements, This permit becomes
null and void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned
for a period of 180 days after the work as commenced, or if required inspections have not been requested within 180 days from the last
inspection, I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of
laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not
presume to give authority to viola!e or cancel the provisions of any state or local law regulating construction or the performance of
construjPj"'
.ifw~ i1/1 f];/ltYf jl-~)-OS-
Signature of tractor or Authorized Agent Date Signature of Owner (if owner is builder) Date
T:\Policies\1102.15R [1105]
PERMIT INSPECTION RECORD
CALL 417-4807 FOR UTILITY INSPECTIONS. PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAWFUL TO COVER,
INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT IN A CONSPICUOUS LOCATION.
KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE
INSPECTION TYPE DATE ACCEPTED COMMENTS
YES NO
PW UTILITIES (Engineering Division)
WATERLINE 1 METER
SEWER CONNECTION
SANITARY
STORM
SITE DRAINAGE
SITE EROSION CONTROL
PARKING
SIDEW ALK
CURB & GUTTER
DRIVEWAY APPROACH
BACK-FLOW DEVICE I
I
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCYIUSE
RESIDENTIAL DATE YES NO COMMERCIAL DATE ACCEPTED
YES NO
CONSTRUCTION R.W.I PWI CONSTRUCTION - R.W.
ENGINEE~G 417-4807 PW 1 ENGINEE~G
FIRE 417-4653 FIRE DEPT.
PLANNING DEPT. 417-4750 PLANNING DEPT.
BUILDING 417-4815 BUILDING
T:\Policies\1102.15R [1/05]
f~'oRT~
,*,4.0~~""
O~~
'IL -=.:It'
~
~.,~
CITY OF PORT ANGELES
PUBLIC WORKS - UTILITIES DIVISION
321 EAST 5TH STREET, PORT ANGELES, WA 98362
Application Number , , . . , 05-00000964
Application pin number 658940
Page 2
Date 11/30/05
Special Notes and Comments
pressurized or pumping to curbs are allowed. An inspection
by Building Department is required prior to backfill.
Address numbers shall be plainly visible from the street,
Address numbers shall be a minimum of six inches high and be
of contrasting color from the background.
All homes in new subdivisions that are outside of the Fire
Department four-minute response area shall be equipped with
residential fire sprinkler systems that comply with the
International Fire Code (IFC) and National Fire Protection
Association (NFPA).
10/25/2005 01:15 PM SROBERDS -- The proposal will result
in a new sfr w/attached garage for total lot coverage of
27%. NO occupancy will be issued until all road and
utility improvements have been installed and approved.
Electrical load calculations and elctrical permits are
required.
Electrical connection fee required of $222.00,
10/19/2005 11:47 AM GMCLAIN ----------------------------
Ditches & 12" culverts will be installed to City Stanards.
See Public Works Engineering for Standards.
Sanitary sewer connection inspection is required by
Public Works prior to back fill of ditch, 24 hour advance
notice is required.
Construct driveway and Sidewalks to City Standards.
No concrete with exposed aggregate allowed in the City
road right of way. An inspection by Public Works
Engineering is required prior to prouring concrete,
Other Fees . , . . . , . .. SEWER SYSTEM DELV CHARGE
STATE SURCHARGE
PW WATER SYSTEM USE FEE
745,00
4,50
1025,00
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
pe'rmi t Fee Total 355.00 355.00 .00 .00
Plan Check Total .00 .00 ,00 .00
Other Fee Total 1774,50 1774.50 ,00 .00
Grand Total 2129.50 2129,50 .00 .00
Separate Permits are required for electrical work, SEPA, Shoreline, ESA, utilities, private and public improvements, This permit becomes
null and void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned
for a period of 180 days after the work as commenced, or if required inspections have not been requested within 180 days from the last
inspection, I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of
laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not
presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
constru~ion,
'/
U;' I
Sighature pf ontractor or Authorized Agent
/ L ft !rrF
1/- SO --(JS-
Date
Signature of Owner (if owner is builder)
Date
T:\Policies\1102_15R [1/05]
PERMIT INSPECTION RECORD
CALL 417-4807 FOR UTILITY INSPECTIONS. PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAWFUL TO COVER,
INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT IN A CONSPICUOUS LOCATION.
KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE
INSPECTION TYPE DATE. ACCEPTED COMMENTS
YES NO
PW UTILITIES (Engineering Division)
WATERLINE 1 METER
SEWER CONNECTION
SANIT AR Y
STORM
SITE DRAINAGE
SITE EROSION CONTROL
PARKING
SlDEW ALK
CURB & GUTTER
DRIVEWAY APPROACH
BACK-FLOW DEVICE I I
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE
RESIDENTIAL DATE YES NO COMMERCIAL DATE ACCEPTED
YES NO
CONSTRUCTION R.W.I PWI CONSTRUCTION - R.W.
ENGINEE~G 417-4807 PW 1 ENGINEE~G
FIRE 417-4653 FIRE DEPT.
PLANNING DEPT. 417-4750 PLANNING DEPT.
BUILDING 417-4815 BUILDING
T:\Policies\1102.15R [1/05]
M'"
o
.......
'"
o
.......
....
....
"''''
DE-<
-0:-0:
Po. 0
NN
OIN
OIN
Mr-
, ,
....r-
co III
"''''
><
..1
0:
'"
H
..1
..1
E-<
",en
~'"
8~
E-<...,
Z
00:
HO
E-<E-<
UU
"''''
Po. Po.
en en
ZZ
H H
00
"''''
MM
:>
H
o
~
en
"''''
ZZ
00
"''''
Po. Po.
E-<
U
,
'-0:
'0:
'0
Q) (J) : 8
"',~
-..1 ,
"'''',
oD'
::,~:
o ,
.......E-<'
rl ~ I a::: a:::
.-lOt . en a::: . ~
Po. , Z 0 ~
~~:CJ)..tJ .~
I ~ 0 , 00 E-< -0: ..1 Z
~~: ~~~~tJ~
LE-<' ozz~~Po.
g:u:~~8o~~
----
UU
ZZ
H H
o
N
ZE-<
o Z r a:::
H~O~
E-1::EoCll
UPo.O
~003:
a::: ~ 1M
E-<"'oZ
en:>r-
Z~oC/)
OQoM
U '0:
o III
8~~~
H...:l . 0\
E-< ....0
(JUoo
~ H 10
t' 0400
rl E-t::EMO
~t;~:3J,~
.-l...:l~Ooo
N
N
....
N
01
III
r-
o
'"
::;:
H
E-<
o
o
'"
00
~
o
'"
Z
'"
Po.
o
o
E-<
en
E-<
~ ~
HZ::;:
~OO
HU
E-<.......
QPo.OO
HHE-<
CIlO:S
~~en
"''''
100:
I-<
....
~Po.~
Po.en~
Zoo
t!lH'"
IZi 0:
....
~
....00
::J",,,,
~E-<E-<
en'"
g!:lo:
0::;:
"'0
I>:~U
Po.
l%I
'"
o
.......
01
0'
....... ,
N ,
0'
,
.. ,
"',
~ ~ : 0 ~
H OQ 0 M
E-<8 >< 8 80 [3 >< 88 8 8~f3 >< 8 8 ~f3><
~ ~ ~ ~~o:~ ~ ~~ ~ ~....~ ~ ~ ~OO:~~
00::: ~ a::: ~ ~(J) M ~~ a::: ~..(J)~M a::: a:::o~CIlM
~~ ~ ~ ~~~~ ~ ~~ ~ ~~~:~ ~ ~~g~~
E-t~ ~H~ ~::E(J)O ~ ~~ ~ ~HQa~ ~ ~rl O~
o H H< ~ , N
o < E-t >t C"I...........
~~ ~3:~ ~ o~ ~ ~~ ~ ~ ~~~~~ ~~....~~
Z Z >< Z ~ H..1
o ~ 0 H~ 0 ~ H E-t...:l
H~~t'H~ OOH m ~HNN rlHM ~ 0 rl ~rl~
E-t..-lo;f'NE-to l!1-=I:ZLn lI1<LllI11l?M l11E-tM .,...,....:1"11' Lll Uo;f'o;r
-0: .. 0 .. -0: .. III .. 3: ",.. .. '" .. .. Z .. III .. -0: ":Ii ....1.... .. ..
oo;rt~OO\"I1'O\a:::~~ ~C/)"I1'~Hrl"l1'''I1'Hrl~~<rlO~HNMM
So~oSo~o~~o~oa:::oO~.-l~O~rlMO~rl~O~~OO
~l!1ool!1~l11~l11~M~~~~~~~~~~~~~~~~~~~~~~
00000001000000 ozo OriO 000
00 O~OQ)Ol?HOQ)Ol?OOl?ooool?o ol?owol?~oo
ZN NZN NZP::NONZNNZN NZNONZN"I1'NZ~NN
H......... .........H......... .........Hp::.........OO.........H..................H......... .........H.........Z.........H......... .........H ..................
9~~~9~~~9~~ ~9~89~ 89~E-t69~ ~9~~6
H.........H.........H.........~.........HO.........~.........H..................H.........~.........H.........~.........H.........::E.........Hm"
~rl~N~NMN~ N~N~MM~N~M~M~M~MOM~~~~
~~~~~~m~~~o~o~oo~o~o~o~o~o~o~oo~~
M
....
I-<
~
I
,
,
,
,
,
,
,
,
,
,
'..1
'..1Po.
,...,-0:
,
,
,
,
'Llllll
'00
, ..............
,........
100
, ..............
'NN
,........
,
,
,
,....
0'0
en,
....... ,
Po. , ....
>< , ..1
I-< , ~
M
..1
~
H
..1
~
..1
..1 Po.
...,-0:
..1
..1 Po.
...,-0:
~
..1
..1 Po.
""-0:
..1
..1 Po.
...,-0:
..1
..1 Po.
...,-0:
..1
..1 Po.
...,-0:
"''''
00
..............
mOl
00
..............
NN
"''''
00
..............
........
00
..............
M M
"''''
00
..............
MM
00
..............
MM
III III
00
..............
0....
NN
..............
NN
........
"''''
00
..............
........
00
..............
MM
"''''
00
..............
........
NN
..............
MM
'"
o
.......
'"
o
.......
....
....
....
o
....
o
....
o
....
o
....
o
....
o
0:
o
..1
~
....
o
~
:;c
~
01
01
..1
~
01
..1
~
N
'"
~
....,
0'
.. ,
'" ,
....'
,
.. ,
"',
::;:,
H ,
E-<'
, ,
, ,
, ,
, ""
, 0'
, .......,
, M
, ....,
, .......'
, N'
, 0'
, ,
I .. I
, "',
, E-<'
.O~l
'00
:~ ~
:.... ~
, .. [3 en
'~~~
Heno
E-<<':
><
0::;:
Po.
"'><
Z~
H .-i N N~
~Zo M~<q'<q'
'" "-0:
(J)~o:t o:tZMM
~~OLflOHOO
~~ ~ ~
'"
~OOI.OOI.O~\.D\.D
~Clo I o~oo
UHOO'\OUOO
HO::NONHNN
~~~co~~~~
::r::>~S::~:I:OO
UO........l1S........U................
00 NMNoo.-i~
~~omo::!:~~
CJ)
E-<
rJ
;;:
Z::;:
00
HU
E-<.......
Po.CJ)
HE-<
~..1
U;J
en 00
"''''
1-<00:
~
Po. E-<
Po...1
6en;J
Zoo
HCi/
~o:
CiI"''''
:EE-<E-<
en",
c"''''
c~'"
0::;:
"'0
o:u
~
I-<
~
Po.
..1
..1 Po.
...,-0:
"''''
00
..............
"''''
........
""
NN
o
en
.......
Po.
><
E-<
....
o
'"
Ci/
::;:
'"
N
I
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
, ,
><0;><
..10 ..1
0:.. 0:
ooMooOO
H.-i~H
'" ><..1
"""0""
'"
::;:
::;:H::;:::;:
PolE-tlllPol
I
I
I
1
I
~
I
I
I
I
I
,
I
I
I
,
I
I
I
1
I
II-<
i~
I Po.
'"
o
.......
'"
o
"
....
....
....
o
01
m
'"
::;:
1
1
1
1
1
, I
1
1
1
1
1
I
,
,
I
I
1
I
I
I
I
I
I
,
I
I
I
I
I
I
I
1
I
I
I
I
I
I
00
E-<
Z
Ci/
::;:
Z::;:
00
HU
E-<.......
Po. 00
HE-<
5s
en en
"'Ci1
o~
I-<
....
~Po.~
Po.OO~
Zen
t!lH'"
IZi 0:
....
~oo
..1"''''
Po.E-<E-<
en",
~~o:
0;;:
"'0
<>:u
...
Po.
'"
~
Po.
E-<
><
'"
Z
o
E-<
Z
o
o
'"
;J
Z
H
E-<
Z
o
U
o
00
.......
Po.
><
E-<
~
.,.\0
o
......
\0
o
......
ri
ri
r.<lr.<l
elE-<
od:od:
000
><
..:l
<>:
r.<l
H
..:l
..:l
E-<
r.<lCll
~r.<l
~~
E-<~
Z ..
0<>:
HO
E-<E-<'
UU
r.<lr.<l
0000
CIlCll
ZZ
HH
o
N
N
N
'"
CIl
r.<l
...:l
\Or.<l
oel
~~
o
......E-<
ri<>:
riO
00
o
r.<l~
<>:0
od:
00><
r.<lE-<
<>:H
OoU
NN
"'N
"'N
"'''
, ,
ri"
"'011
\0'"
00
\0\0
"''''
~
o
[g
en
r.<lr.<l
ZZ
00
XX
0000
UU
~~
ZE-<
o Z ' <>:
H~O~
f-t::EoC1l
UOoo
::>00;3;
ll:: ~ I ~
E-<r.<loZ
en:>"
Zr.<loen
E-< 000r.<l
U U I ~
0011
a~~~
H.4IO\
E-< riO
(JUOO
.ct H 10
t'-- Oloo
...... f-t::EMO
~b~~~~
rlH:J:OOO
od:
<>:
o
f3
od:
<>: <>:
. <II <>: . r.<l
ZO <II
gJ E-<'~ ..:l ~
~~E-<&l[L
o~~~~g;
;i!E-<UOOood:
r.<l
E-<
..:
o
~g ~
i;J,;;<>:?i
~rl::>CI)
~ .. ?i ~
~r.<leno
:0:":
H><
><:0: :O:E-<O:O:
HA.L/lp,. AI
00 011 ><
00.,. <II
::>\DOO\Z M N M'<1'
tnlfl'MHZO M 'l:;f'o;;;f'
.. 0'\ .. I ~ ..
ll::NO~:Z:::'::'<1' '<1'..:JMM
1YI0COOC!)..:(OLllo-=C00
E-< ::>E-<.,. Z
I':( 0 o;;;f' H
~\O:Z:\OP::;M\DO\D~\D\D
OlJ.tO c:lOIQ 00
C!)o OCJHOO\Ot'JOO
ZN~NZP::;NONZNN
~::t~~~~-;:;-CX):;~~::;-
~~Z.::.~~~~~~~~
Hr-IONH N..-iN...:!..-lr-l
A!OZOo.."'Ort!OAi....-iM
o
o
'"
ri
r.<l
:0: en
Hod:
E-<><
o
en
E-<
Z
r.<l
:0:
Z:O:
00
HU
E-<......
00 en
HE-<
els
en en
r.<lr.<l
0<>:
E-<
Oo..:l
en::>
zen
Hr.<l
<>:
..:l
..:l00
~od:
..:l
..:l00
~od:
00
r.<lr.<l
E-<E-<
enr.<l
r.<l..:l
::>Po
0:0:
r.<l0
<>:U
\0\0
00
............
ri ri
00
............
NN
\0\0
00
............
.,..,.
riri
............
NN
o
en
......
Po
><
E-<
ri
o
ri
o
\0
..:l
00
N
..:l
Po
N
ri
N'
o ,
.. ,
\0,
ri'
,
.. ,
r.<l'
:0:'
H ,
E-<'
\0
o
......
'"
ri
......
N
o
>< ><
..:l ..:l
<>:0 <>:
IilOCl)Iil
H..~H
HM)-lH
~riO~
en
r.<l
E-<
o
Z
o
~
:O:r.<l:O::O:
00:0:0000
H
E-<
en
E-<
Z
r.<l
:0:
:0;:
o
U
,
,
,
,
,
,
,
,
,
~
1+-:
o ,
,... ,
,
o ,
...... ,
ri ' ,
ri ,
,
,
,
ri ,
o ,
,
'" ,
'" ,
..:l ,
0. ,
11/05/2005 15:21
3505813992
WANT ACTION CONST
.
PAGE 02
lo...-~il.....- ~~_a;-~:=~---'"
-j~. --,..-
\{
............
t
..........-.
~
~
~
\\
~
\.
....\0 ,
0 ,
....... , ....
.... , N
N ,
....... , '" ,
M , LIl ,
, .. ,
, r- ,
, 0 ,
, ,
r>1r>1 , .. ,
el[-< , r>1 ,
<t:<t: , :0: ,
I><Q , H ,
, [-< ,
, ,
, ,
, ,
, \0 ,
, 0 ,
NN , ....... ,
"'N , '" ,
"'N , 0 0 ,
Mr- , 0 ....... , ~
' , , .. N ,
....r- , M 0 ,
CDLIl , .... , ~ '"
\O'<l' , .. ,
, .. r>1 , '-
, r>1 [-< ,
>< 00 , :0: <t: , 0
..:l \0\0 H OQ 0 ~
<>: "'M [-<..:l ..:l O~ ~ ..:l ..:l 8';;~
r>1 0 >< 0 >< 00 0 0 )
H :I: ..:l :I: :I:'" ..:l :I::I: :I: :I:.... ..:l :I:
..:l [-< <>: [-< ~""!3en <>: [-<[-< [-< [-< <>: [-<
:> 2~ r>1 <>: r>1 ~~ ~ p:: .. en Lll rI1 ~ "-
..:l H r>1r>1 H <t: ~~~~ H <t:r>1<t:'<l'H
[-< Q ZZ HIIl ..:l III ..:l IIlIIl III 1Il:O:><'<l'..:l III en 'Q
r>1en ~ 00 [-<I>< '"o..:ll>< l><:o:enQ '"0 1><1>< I>< ~H~OI-J I>< r>1
~r>1 :X::X: 0 ..:l H<t: .... , ....
~~ en 1><1>< 0 <t: ....>< '" 0 \~\
"-:0: ~~~ ~ Q~ :0: :0::0: ~ :0: ~~~~~ Z
....'"0 I>< I>< 1><1>< I><
Z Z >< Z III ~
Z 0 LIl 0 ..:l1Il 0 "" H ~
0<>: t H r......~. r- H .., CD"" '" "'HNN ....HM '<l'
HO en f-tr-l...tNE-tO I.fI~ZU1 ltl,::(LllLllC!JM Lllf-lr"J ....,H..,
........ .... <t: .. 0 .. <t: .. LIl .. ~ r>1.. .. r>1 .. .. Z .. LIl .. <t: ":I: ....:l .. en
uu Z ~"'l..,om..,m~~r- ..,cn"''''Hr-4'''~Sr-4~''',::(MO .... ~
r>1r>1 ~ r>1 omoSo..,o ,::(OLllO OO~M"'O 1""""4 O~M~ Z
1><1>< HZ~ o 0 WE-t .., p:: 0 en W ~ m r>1
en en ~LllOOU1~Lll~I.fI~W~6~~~~~~~~~~~~~~~ ~
ZZ ffioO
H H UU HU 0 o 000 0.010 00 000 OZO OM 0
~~ ........... elo OC!JOoooC!JHoroaC!JooC!JoroaC!Jo oC!Jo~ U "-
Ql><en ZN NZN NZP::NONZNN'ZN N'ZNON'ZN'"
HH.... H....... 'H' 'HP::,ro'H"H' 'H'Z'H' ,
Z[-< en<>:..:l ~oZrlOO r-Iowm mOMMOro ~ON MOM ,
OZ ,<>: [:lUO HM~OHN~NH>O~OHOOHNjOHOE-tOHN ,
HrI10~ en en H'H'H'~'HO' 'H"H' 'H'~'H'~ ,
E-t:EoCJ) r>1r>1 ~MHN~NMN~ NHN~M""~N ""~MrI1M~MO ,
UI><O 1Q<>: mM,::(MmM~Mm.o,::(omoomo,::(omOHomOE-t ,
OOO~ ,
P::: H I rI1 [-< ,
E-<r>1OZ H ~t ,
en:>r- ~I><~ ,
Zr>1oen ,
0 [-< OOoW ,
N U U ,<>: p<eno ,
Z~~'<l' zen ..:l ..:l ..:l ..:l ..:l ..:l ,
.... <t: C!lHr>1 ..:lP< ..:ll>< ..:ll>< ..:ll>< ..:ll>< ..:ll>< ,
'<l' <>: o r-\O :z; <>: '"o<t: '"o<t: '"o<t: '"o<t: '"o<t: '"o<t: ,
0 H..:l ,'" H ,
.... !3 E-< ....0 ~ ~
....en (JUOO
r>1 <t: <t:H '0 HQQ
-..:l r- 1><00 =>r>1r>1 LIlLll LIlLll \0\0 \0\0 \0\0 \0\0
\Or>1 .... E-t:t:MO 1IlE-<E-< 00 00 00 00 00 00 o ,
oel ~b~:3~~ enr>1 .............. .............. .............. .............. .............. .............. ....... ,
::.~ g[:l~ ........ 0.... "'''' ........ ........ "'''' .... ,
MH3=OOO 00 NN 00 00 00 00 N ,
N 0:0: .............. .............. .............. .............. .............. .............. ....... ,
.......E-< r>10 NN NN NN MM MM MM M ,
M<>: <>: <>: <>:<>:U ........ ........ ,
0 '1Il <>: -r>1 P< ,
I>< ZO III III ,
Q E-< . ~ ,
r>1"- en -U .... .... .... .... .... .... .... ,
<>:0 enE-<;2 ..:l !-< a 0 0 0 0 0 0 0 ,
<t: ~~E-<~tl..:l H en ,
1><>< ~ ....... <>: <>: ,
r>1E-< Q1.1si~~ I>< .... N '" H '" H Q ,
<>:H >< ..:l ..:l ..:l <t: ..:l ..:l ..:l ,
I><U ~E-<UOI><<t: P< E-< III III III III III III III ,
M\D
o
......
M
o
......
M
0l0l
~E-<
.0:.0:
0.0
NN
OIN
OIN
M....
, ,
........
lDlI1
\D""
><
..:l
<>:
Ol
H
..:l
..:l
E-<
OlUl
~Ol
8~
E-<'J
Z ..
0<>:
HO
E-<E-<
UU
0l0l
0.0.
UlUl
ZZ
H H
00
\D \D
MM
~
H
o
gJ
Ul
0l0l
ZZ
00
:X::X:
0.0.
UU
~~
01
....
....
o
ZE-<
8ffi~g:
E-t::EoOO
uo.o
::000;3'
0:: ~ r ru
E-<OloZ
~&i~CI)
E-< Ooor>l
U U ,<>:
Z~~""
o ....\D
H '01
E-< ....0
UUOO
tc( H 10
["'- t::Lloo
rl f-'l:EMO
~~~~~~
r-f~:J:OOO
;:!
o
is
.0:
M
....Ul
r>l
-..:l
\DOl
o~
~~
o
......E-<
M<>:
o
0.
o
0lC>.
<>:0
.0:
0.><
OlE-<
<>:H
o.U
<>: <>:
. <Il <>: . Ol
ZO <Il
~ E-<-~ ..:l ~
~~E-<gjtl..:l
offi~~~g:
~E-<uoo..o:
Ul
E-<
~ ffi
HZ~
1:88
SlE-<......
Oo.Ul
HHE-<
m<>:s
~~Ul
Olr>l
'0<>:
E-t
....
~o.~
o.Ul::O
ZUl
(!lHOl
:z; <>:
....
~
SfiH'l
1IlE-tE-<
Ulr>l
ggJ~
0:;:
010
<>:<>:u
0.
<Il
E-t
i
0.
....
N
01'
lI1'
.. ,
....,
o ,
,
.. ,
Ol'
:;:,
H ,
E-<'
,
,
,
\D'
0'
...... ,
01'
o 0 ,
o ...... ,
N'
M 0 ,
.... ,
,
Ol'
Ol E-< ,
::t tc( I 0
H 00 0
E-<5 >< 5 o~ !3 >< 05 5 OM
~ ~ ~ ~~~~ ~ ~~ ~ ~....~
i~ ~ ~ ~.. ~ ~ ~~ ~ ~~~~
Hm ~ m moo ~ H moo m oo::t~~
E-<o. 'J..:lo. o.:;:UlQ 'J 0.0. 0. o.HOO
o ~ Htc( ~ 1
o tc( E-t~ m
C>.~ ~~~ ~ O~ ~ ~~ ~ ~ ~~
Z Z >< Z
o ~ 0 HOO 0 ~
H["'-~["'-H~ OOH m ~HNN M r-fHM
~~~~~~~~~ffi~ ~~~~~~~~~~~
~~l~om~mo::~~ ~m~~Hr-f~~Hr-f~
omoZo~otc(tc(o~o OO~r-f~O~r-f
o ~ 0 ~E-t ~ 0:: ~ a en 00
~~OO~~~~~ffiM~~~~~~~~~~~~~
000000010 ao coo az
00 oOoooaOHooooOaaOooooOa
ZN NZN NZO::NONZNNZN NZNO
H' 'H' 'HO::'OO,H"H' 'H'Z
QaZr-fQo r-fooom mQr-fr-fQoo r-fON
HMWaHN~NH>ajaHaaHNZOHaE-t
H'H'H'~'HO' 'H"H,tc('H'~
~r-fHN~NMN~ N N~MM~NHM~MM
mr-ftc(r-fOOr-fmr-fOO~otc(aooaooootc(omOH
Ul
Ol
E-<
o
Z
o
~
Ul
E-<
Z
Ol
~
o
u
..:l
..:lo.
'J.o:
..:l
..:lo.
'J.o:
..:l
..:lo.
'J.o:
..:l ..:l
..:lo. ..:lo.
'J.o: 'J.o:
1I1111
00
............
........
00
............
NN
........
\D\D
00
............
........
00
............
MM
~
1I1111
00
............
0....
NN
............
NN
........
\D\D
00
............
mOl
00
............
NN
\D\D
00
............
........
00
............
MM
o
Ul
......
0.
><
E-<
....
o
....
o
....
o
....
o
....
o
....
o
<>:
:;:
<Il
....
..:l
<Il
01
..:l
<Il
N
..:l
<Il
M
..:l
<Il
H
..:l
<Il
r--
..'"
0
...... ....
.... '"
0
...... '" ,
'" '" ,
.. ,
.... ,
0 ,
,
r.lr.l .. ,
~E-< r.l ,
..;..; ::E ,
o..Q H ,
E-< ,
,
,
,
'" ,
0 ,
"'''' ...... ,
"'''' '" ,
"'''' 0 0 ,
"'.... 0 ...... ,
, , '" ,
........ '" 0 ,
"'''' .... ,
"'.. .. ,
r.l ,
r.l E-< ,
>0 00 ::E ..; ,
..:I "'''' H OQ ~
0>: "'''' E-<..:I ..:I ..:10 ~ ..:I
r.l 0 >0 0 0" >0 0
H :x: ..:I :x: i'i:::~ ..:I :x:
..:I E-< 0>: E-< 0>: E-<
;> ~~ r.l ~ ~.. ~ r.l ~
..:I H r.lr.l H H
E-< Q ZZ H~ ..:I ~ 1Ilr.l >0 ..:I III UJ
filUJ gJ 00 E-<o.. 'J..:Io.. o..::EUJQ 'J 0.. fil ~
l><:r.l ::r:::r: 0 ..:I H"; E-<
~:i! UJ 0..0.. 0 ..; E-<>O 0
r..::E iP:i! :i! Q:i! ::E :i! Z
E-<'J 0.. 0..
Z Z >0 ~
Z .. 0 '" 0 ..:I1Il
00>: Ht"'o::JIt"'-H"'" "'..:I '" ..
HO UJ E-+M~NE-+O IJ1A;ZLll If'lClr<)
E-<E-< E-< ..; .. 0 ....; .. '" .. ~ r.l.. .. Z .. '" UJ
uu Z 0..:' I o:t~",oqoO'\~~r-- ~Hrl~ E-<
r.lr.l ~ r.l Somo O~O ..:x:01I10~.-i~ Z
0..0.. HZ~ o 0 ~E-+ ~ 0 r.l
UJUJ o co 0 I ~ 'O;Jl I ~
ZZ ~OO ~ll'l 1J1~l.t'lmltl(()M\"oolJ)t:r.,,\.OO\
H H UU HU 0 0 000 00 10 00 0
ZZ E-<...... ~o oOocooOHoooaCloco U
H H i:lo..UJ ZN NZ", NZ~NONZN
HHE-< H...... ......H...... ......Hp:;......CO.........H........
ZE-< UJO>:S 00:;2;1'""'400 r-lQOOm "'Q'"
o Z I ~ ~~UJ ~~~.::~~~~~g.::~.::~~~
HMot:r." 4.
E-t);oU) r.lfil ::Jr-l.....:lN::JN......N:::J NHN::>NH
Uo..o 'QO>: ~rllC(rllXl..-l rnr-llIJ'" oIC(OIXlOlC(
::>OO~ E-<
0>:..:1 'r.l
E-<filoZ H
UJ;>.... ~o..~ ~
Zr.loUJ
'" E-< OQor.l
.. U U '0>: ll<UJ
z~~~ t!l~gJ ..:I ..:I ..:I ..:I
N ..; ..:10. ..:10. ..:10. ..:I
.. 0>: o ....'" :z: 0>: 'J"; 'J"; 'J"; 'J ,
0 H..:I ,'" H ,
'" ~ E-< ....0 ~ ,
....UJ UUoo -*
r.l ";H '0 ~QQ
-..:I .... 0..00 r.lr.l ''''''' "'''' "''''
"'r.l .... E-t::!:MO E-<E-< '00 00 00 ~ , :
o~ ~~~~~~ UJr.l , ............ ............ ............
::.~ g~~ ,........ 0.... "'''' .... ,
r-lH~OOO '00 "'''' 00 o .... ,
0 0:';: , ............ ............ ............ ...... ,
......E-< r.lO ''''N "'''' "'''' '" ,
"'0>: 0>: 0>: i>lo>:U ,........ ........ ,
0 '1Il 0>: 'r.l p., , ,
0. ZO III i%l , ,
Q E-< ,
r.lr.. UJ -U ~ , .... .... .... ....
~O UJE-<~ ..:I E-< 0 , 0 0 0 0
~~E-<<J..:I H UJ ,
0.>0 ~ ...... ,
filE-< Qi:l~~~g: 0.. , .... '" '" '"
O>:H >0 , ..:I ..:I ..:I ..:I
o..U ~E-<UOOo"; Po E-< , III III III III
"''''
o
.......
'"
...
.......
N
MOO
OE-o
<<
"'Q
NN
"'N
"'N
M....
, ,
.......
<Xllll
"''''
><
..:I
I>:
00
H
..:I
..:I
E-o
MOO
:':00
8~
E-o">
Z oo
01>:
HO
E-oE-o
UU
MOO
"''''
0000
ZZ
H H
00
"''''
MM
:>
H
Q
gJ
00
MOO
ZZ
00
:I::I:
"''''
UU
ZZ
H H
'"
o
ZE-o
o Z , I>:
H~Orr..,
E-t:EoCll
U"'o
::>003:
P::: ~ I ~
E-oMOZ
~~~cn
E-o OQoM
CJ U I P:::
Qlll
~~~~
H ~ I C\
E-o ...0
UUoo
,::( H 10
r-- 114oo
.-I E-t:EMO
~~~:s~~
MH:J:OOO
N
M
M
...00
00
...:1
"'00
00
:;:~
...
.......E-o
NI>:
o
'"
Q
M~
1>:0
<
"'><
ME-o
I>:H
"'U
;2
o
!3
<
I>: I>:
. lJJ P: . tJJ
ZO III
oo.t; .~
gjE-o;2dlZ
I>:~E-oMU..:I
Qfa~~~g:
~E-oUO"'<
00
E-o
Z
00
Z~
00
HU
E-o.......
"'00
HE-o
1>:..:1
u::>
0000
MOO
!-tQI>:
i
'" E-o
"'..:I
600::>
zoo
HM
~Q:
MMM
lEE-oE-o
0000
000..:1
0::>'"
0:>;:
000
I>:U
~
!-t
i
'"
'"
N
...,
0'
oo ,
""
...,
,
oo ,
00'
:>;:,
H ,
E-o'
,
'"
o
.......
M
...
.......
N
o
00
. E-o
'0<
'OQ
:~ ~
:... ~
:M!3~
1:E~)-t
IHCIlO
'E-o<
, ><
. Q:>;:
, '"
.00><
ZIIl
H ...
..:IZo
00 oo
00:':'"
-=C.c:COlll
OE-o '"
'"
H~\OO
<QOI
(JHom
H!l::NO
~gj;:'<Xl
O~.:::~
00 N'"
::E:'" 0 res
,
,
,
,
,..:I
'..:1
.,,>
.
,
,
1
,'"
'0
, .......
''''
,...
1 .......
IN
1
,
,
,
,...
010
00'
....... ,
'" , '"
>< 1 00
E-o , :>;:
00
E-o
Z
00
:>;:
Z:>;:
00
HU
E-o.......
"'00
HE-o
eJS
0000
MOO
I'll>:
!-t
...
~"'~
"'00::>
ZOO
OHM
:z: I>:
...
~QQ
~MM
"'E-oE-o
0000
g[g~
0:>;:
000
I>:U
..:I
'"
!-t
i
'"
.
,
,
,
0'
0'
oo ,
~!3
M~
:>;:00
H<
E-o><
Q
N
...
N'
0'
oo ,
""
...,
,
1
00'
:>;:1
H 1
E-o'
'"
o
.......
M
...
.......
N
o
00
E-o
<
Q
o
><0
..:I oo
ei~g;cn
~ oo ~ ~
,,>MOOQ
:>;:<
H><
><:>;: :>;:E-oQ:>;:
HPlll'l~ ll4
'" III ><
'" '" III
=:>\OOO\Z r-l
CIlLn I MHZO
.. m .. I rI1 ..
P:::NO o::r::r:::.=:..,.
[IlOCDOCJlC(OU)
E-o ::>E-o '"
< 0 '"
~\O::r:\OP::M\OO
O~O QO_
CJo OClHom
ZNt;lJNZP:NO
~::t~::t;:Q~:;;-aJ
~~z~~g;.:::~
~.-IONH N......
Cl!aZoa....o!U
o
00
.......
'"
><
E-o
"''''
00
..............
......
00
..............
NN
..:I
..:I'"
"><
~t
~
...
o
...
o
'"
..:I
'"
N
..:I
'"
00
00
E-o
o
Z
Q
~
00
E-o
fa
~
o
U
CITY OF PORT ANGELES.
FIRE DEPARTMENT PERMIT
321 East 51h Street, Port Angeles, W A 98362
Application Number
Application pin number
Property Address
ASSESSOR PARCEL NUMBER:
Tenant nbr, name
Application type description
Subdivision Name
Property Use
Property Zoning . , .
Application valuation
05-00000964 Date
658940
1401 AURORA CT
06-30-01-7-5-0070-0000-
LOT 7
RES NEW SFR
2/15/06
RS9 RESDNTL SINGLE FAMILY
189240
Owner
Contractor
OLYMPIC LAND DEVELOPMENT INC.
259403 HWY 101
SEQUIM WA 98382
(360) 457-7222
Other struct info
WANT ACTION CONSTRUCTION
P. 0, BOX 1425
SEQUIM
(360) 681-3992
TOTAL % LOT COVERAGE
NUMBER OF STORIES
LOT SIZE
TOTAL LOT COVERAGE
NUMBER OF UNITS
INC,
WA 98382
27.00
1. 00
9008,00
2398,00
1. 00
Permit FIRE SPRINKLER RESID
Additional desc
Permit pin number 70847
Permit Fee .00 Plan Check Fee ,00
Issue Date 2/15/06 valuation 0
Expiration Date 8/14/06
Special Notes and Comments
Building address sign shall not be less than 6" & not more
than 12" in height. N~ers colors must contrast with wall
color they are mounted on, (Ord. 14.36.050-E) .
When roof gutters are installed, drains will located ~n dry
wells or piped to approved storm drain location. No
pressurized or pumping to curbs are allowed. An inspection
by Building Department is required prior to backfill,
Address numbers shall be plainly visible from the street,
Address numbers shall be a minimum of six inches high and be
of contrasting color from the background,
All homes in new subdivisions that are outside of the Fire
Department four-minute response area shall be eq~ipped with
residential fire sprinkler systems that comply w~th the
International Fire Code (IFC) and National Fire Protection
Association (NFPA),
10/25/2005 01:15 PM SROBERDS -- The proposal will result
in a new sfr w/attached garage for total lot coverage of
27%. NO occupancy will be issued until all road and
utility improvements have been installed and approved,
Electrical load calculations and elctrical permits are
required,
Electrical connection fee required of $222.00.
10/19/2005 11:47 AM GMCLAIN ----------------------------
Ditches & 12" culverts will be installed to City Stanards.
See Public Works Engineering for Standards.
Sanitary sewer connection inspection is required by
Public Works prior to back fill of ditch, 24 hour advance
notice is required,
This penn it becomes null and void if work authorized is not commenced within 180 days, if work is suspended or
abandoned for a period of 180 days afer the work has commenced, or if required inspections have not been requested with
180 days from the last inspection. I hereby certify that I have read and examintrl this application and know the same to be
true and correct. All provisions of recognized standards, laws and ordinances governing this type of work will be compled
with whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel
the provisions of any state or local law regulating the work specified in the permit.
OG
te Signature of Owner (if Owner is builder)
Date
Signature of Contractor or Autho Ized Agent
FIRE PERMIT INSPECTION RECORD
Call 360-417-4655 for fire inspections. Please provide a minimum 24-hour notice. It is unlawful to cover, insulate
or conceal any work before inspected and accepted. Post permit in a conspicuous location.
KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE
FIRE SPRINKLER
Underground piping hydrostatically tested
Underground piping flushed
Interior piping hydrostatically tested
Interior piping inspection
Dry system air tested at 40 psi (24 hours)
Sprinkler final
FIRE ALARM
Rough-in inspection
Alarm final
LP-GAS Completed by Contractor:
Underground piping inspection/pressure test Test #1
Above ground piping inspection/pressure test Piping pressure test ' pSI
Tank (container) inspection Time initiated
Test #2
Appliance inspection Piping pressure test pSI
Time initiated
LP-gas final
UNDERGROUND STORAGE TANK (UST) ABANDONMENT
Removal of flammable/combustible liquids
Tank appropriately abandoned
UST abandonment final
PERMIT OTHER (specify)
permit final
Inspection Type
I Date Passed I
Comments
GENERAL COMMENTS:
2/15/00
CITY OF PORT ANGELES
FIRE DEPARTMENT PERMIT
321 East 51h Street, Port Angeles, WA 98362
Application Number , , , , , 05-00000964
Application pin number 658940
Page 2
Date 2/15/06
Special Notes and Comments
Construct driveway and Sidewalks to City Standards,
No concrete with exposed aggregate allowed in the City
road right of way. An inspection by Public Works
Engineering is required prior to prouring concrete.
Other Fees . . . . . , , , ,
SEWER SYSTEM DELV CHARGE
STATE SURCHARGE
PW WATER SYSTEM USE FEE
745,00
4.50
1025.00
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total ,00 ,00 ,00 ,00
Plan Check Total ,00 .00 .00 .00
Other Fee Total 1774,50 1774,50 .00 .00
Grand Total 1774,50 1774,50 ,00 ,00
This permit becomes null and void if work authorized is not commenced within 180 days, if work is suspended or
abandoned for a period of 180 days afer the work has commenced, or if required inspections have not been requested with
180 days from the last inspection, I hereby certify that I have read and examimrl this application and know the same to be
true and correct. All provisions of recognized standards, laws and ordinances governing this type of work will be compled
with whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel
the provisions of any state or local law regulating the work specified in the permit.
Signature of Contractor or Authorized Agent
Date
Signature of Owner (if Owner is builder)
Date
FIRE PERMIT INSPECTION RECORD
Call 360-417-4655 for fire inspections. Please provide a minimum 24-hour notice. It is unlawful to cover, insulate
or conceal any work before inspected and accepted. Post permit in a conspicuous location.
KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE
FIRE SPRINKLER
Underground piping hydrostatically tested
Underground piping flushed
Interior piping hydrostatically tested
Interior piping inspection
Dry system air tested at 40 psi (24 hours)
Sprinkler final
FIRE ALARM
Rough-in inspection
Alarm final
LP-GAS Completed by Contractor:
Underground piping inspection/pressure test Test # I
Above ground piping inspection/pressure test Piping pressure test ' pSI
Tank (container) inspection Time initiated
Test #2
Appliance inspection Piping pressure test pSI
Time initiated
LP-gas final
UNDERGROUND STORAGE TANK (UST) ABANDONMENT
Removal of flammable/combustible liquids
Tank appropriately abandoned
UST abandonment final
PERMIT OTHER (specify)
permit final
Inspection Type
I Date Passed I
Comments
GENERAL COMMENTS:
2/15/00
,---~-
PORT ANGELES FIRE DEPARTMENT
102 East Fifth Street, Port Angeles, Washington 98362
(360) 417-4650 FAX (360) 417-4659
Fire Sprinkler System Plan Review
Project Name: Private Residence Address: 1401 Aurora Ct.
Installer: Innovated Fire Sprinkler Installer Telephone: 452-7583
Type of System: Open 130 13RO 13D~
Date: 2.10.2006 P AFD Permit #: 06-14
We have checked this plan and find that it conforms to the requirements of the code.
Additional Comments:
All systems, including underground mains, shall be installed by a state licensed and certified
company, Systems shall be installed per the applicable NFP A Standard,
All electrical components shall be compatible with the fire alarm system,
A design sprinkler flow test and alarm test are required for all 13D systems.
Before final acceptance of the system, an inspection will be conducted to ensure that the
installation complies with the applicable NFP A Standard, This 13D system will require a
measured flow test.
Contractor
Reviewed by: ~QD ~
Date: ~'\c'a6
o
~
o
Building Department
Fire Department
BUILDING PERMIT - APPLICATION
Fill out COMPLETELY and in INK. Your application and site plan MUST BE
COM:PLETE to be accepted for review. If you have any questions, call
PERMITS (360) 417-4815 FAX(360)417-4711
Applicant or Agent: V~ Y\.C-9-V\.f- ~ e., ++~ ~ Phone: '-I.) 2 -7-S 83
. Owner: I.A/RAlTn /}-Cr / ON c..OAIS7R. Phone:
Address: f~ 0, [SOX 1'-I2S City: Se..~ L~J~ Zip: 993~ 2-
Architect/Engineer: Phone:
Contractor I NNOJ/A-T.GtJ '::/~ State License #:JA//V()jlqo lfli!I(~/;Z/66 Phone: 4S2 - 7.s8"l
. , ,
III ~ IJ o...cJ .e.-t..., k. l.-. City: Po,,}- /i'--:j.Q &.. .f Zip: CZ ~ J 6 '<-
PROJECT-ADDRESS: ,,1 '101 ' It ~ Co'-"-V' .f-
7"
Address: 8 J
ZONING:
LEGAL DESCRIPTION: Lot:
CLALLAM COUNTY PARCEL NUM:.BER:
Block
Subdivision:
Credit Card Holder Name:
Billing Address:
Credit Card Type VISA MC #
TI..'PE OF WORK:
?5:' Residential 0 New Constr. 0 Re-roof
o Multi-family 0 Addition 0 Move
o Commercial 0 Remodel 0 Demolition
o Repair 0 Sign
BRIEF DESCRIPTION OF THE PROJECT:
City:
Exp. Date:
o Stove
o Garage
o Deck
o Other
F- .
iV-~
SIZE/V ALUATION:
SF. @ $ /SF. = $
SF. @ $ /SF. = $
SF, @ $ JSF, = $
\ T01AL VALUATION J $ 2..2-00.
Srv-.1..1. k'RI' S~ t::g '^-
ocJ
COMMERCIALIRESIDENTIAL: Occupancy Group:
No, of Stories: _ Lot Size: Existing Sq. Ft.
Total lot coverage %
Occupant Load:
& Proposed Sq. Ft.
Construction Type:
= TOTAL Sq. Ft.
APPROVALS:
PLAN:
,BLDG:
DPWU:
FIRE:
OTHER:_
PLANNING USE ONLY:
ESA/Wetland(s): 0 Yes 0 No SEPA Checklist required? 0 Yes 0 No Other:
VALUATION OF CONSTRlJCTION: In all cases, a valuation amount must be entered by the applicant. This figure will be 'reviewed
and may berevised by the Building Division to comply with current fee schedules, Contact the Permit Coordinator at 417-4815 for assistance.
PLAN CHECK FEE: IF-a plan check fee is due it mustbesubmitted at the time the building permit application and Construction plans are
submitted. All other permit fees are due at the time of permit issuance,
EXPIRATION OF PLAN REVIEW: Ifno permit is issued within 180 days of the date of application, the application will expire. The
Building Official can extend the time for action by the applicant up to 180 days upon written request by the applicant (see Section Rl 05.3.2
of the International BuildinglResidential Code, 2003). No application can be e},.1ended more than once,
J hereby certify that J have read and examined this application and know the same to be true and correct. J am authorized to apply for this permit and
understand that ft is my respDnsibiDty tD deteJi": what pennits are required ,nDt the CitY', and fha~ } must Dbloin such pennits prior to worlr.
np"lioi~\B["I102_13.wpd Appli",,'" ~~ I /J~ z J 7/ d <;.
~ OG:,-I 'f
\0\0
0
, M
'" N
0
, '"
N U'l
....
0
MM
OE-o M
<(<( :(
0.0 H
E-o
\0
0
NN ,
"'N '"
"'N 0 0
M.... 0 ,
, , N
M.... M 0
COU'l M
\0'"
M
M E-o
>< 00 :( <(
..:I \0\0 H 00
I>: MM E-o..:l O~ ~
M 0 >< 0
H :I: ..:I :I: i5~~
..:I E-o I>: E-o
;> [;g~ M ~ ~.. ~
..:I H MM H
E-o 0 ZZ Hill ..:I III IIlM >< en
Men gj 00 E-oo. ">..:10. o.:(eno M
:<:M :I::I: 0 ..:I H<( E-o
~~ en 0.0. 0 <( E-o>< 0
0.:( ~3~ ~ O~ Z
E-o"> 0.
Z Z >< 0
Z .. 0 U'l 0 ..:I III :J!
01>: Hr--~r--H~ CO..:l '"
HO en ~~~~~~LJl~~ffi~
E-oE-o E-o en
UU &i ~ '" , '" ~ '" '" "'~:<:.... E-o
MM ~ 00'\0 o~o Il:(OU"l &i
0.0. o 0 ME--i ~
en en HZ~ 0 co 0 , :I: '" ~
ZZ ffiOO 0.U'l It)tJ.,,lt)O'\UlOOM\OO
H H UU HU 0 0 000 00' 0
~~ E-o' 00 OClOCDOC)HOCD U
o 0. en ZN NZN NZ~NO
HHE-o H' 'H' .........He::.........a>
ZE-o enl>:S OOffir-lQO 1-Ij:~Mm
o Z , I>: ~~en ~,..., O~Nt::NH:>Oj
HMOrz.. H.......~.......H.........ns.......HO.......
E-o:(oen MM ~riHN~N.-iN::> N
Uo.o 101>: i:Ori~r-llIlr-lmMlII.o~
::>003 E-o
C::...l 1M
E-oMOZ H
en;>.... ~o.~ ~i
ZMoen
U'l E-o OOoM
0 U U II>: 0. en
z~~~ zen ..:I ..:I
0 ;:! OHM ..:10. ..:10.
M o ....\0 Z I>: "><( "><(
0 H...l 10'\ H
M 13 E-o MO ~
Men UUoo
M <( IC( H 10 t;l00 ~
...:1 .... 0.00 MM U'lU'l U'lU'l
\OM M E--i:EMO IIlE-oE-o 00 00
00 ~b~~~~ enM " "
~:J! g~~ MM OM
r-l...:!:J:Ooo 00 NN
0 0:( " "
'E-o MO NN NN
NI>: I>: I>: ll:I>:U MM MM
0 . III I>: 'M 0.
0. ZO III III
0 E-o
Mo. en . U ~ M M M
~O enE-o;:! ..:I E-o 0 0 0 0
... en
0.>< g]:J!E-01:ltJ..:I ~ ,
ME-o O&is~~~ 0. M N '"
I>:H >< ..:I ..:I ..:I
o.U ~E-oUOo.<( 0. E-o III III III
"'ID
o
.....
....
o
.....
N
MM
~E-<
<(<(
"'Cl
NN
"'N
"'N
""r-
, ,
....r-
"''''
ID.,.
><
..:I
P:
M
H
..:I
..:I
E-<
MOO
:<:M
~~
E-<~
Z ..
OP:
HO
E-<E-<
UU
MM'
"''''
0000
ZZ
H H
00
IDID
""""
;>
H
Cl
gJ
00
MM
ZZ
00
:>::>:
"''''
UU
ZZ
H H
o
.,.
ZI-<
8Ea~g:
f-l:E:ocn
U"'o
::>Oo~
p:: ~ I ~
E-<MOZ
OO;>r-
ZMoCJ)
E-< OCloM
U U 'll::
<( Z~~'"
p:: 0 ['\0
o H I 0\
p:: E-t ....0
8 UUoo
..... < H 10
r-- ~oo
.... f-l:E:MO
~~~~~~
r-t~~Ooo
o
""
N
....00
M
-..:I
IDM
o~
::.-~
o
.....1-<
NP:
o
'"
Cl
Mr>.
~o
"'><
ME-<
P:H
"'U
P: P:
. III P: ' M
ZO III
00 . tJ . ~
OOE-<~ ..:IZ
g]~E-<<J..:I
Cli:1S~~g;
~E-<UO"'<(
00
E-<
Z
M
Z~
00
HU
E-<.....
"'00
HE-<
!JS
0000
MM
ClP:
E-<
H
~"'~
"'00::>
ZOO
~HM
~ P:
iClCl i~
~WOOI\O
Cl.l f-l f-l 10
OOM'
~ ~i : ....
OlE:'
MOl N
P:U'
..:l ,
'" ,
,
, ....
0'0
00'
..... ,
'" , ID
>< , ..:I
E-< , '"
E-o
i
'"
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
0'
0'
.. ,
~~
lE:OO
H<(
E-<><
Cl
00
M
I-<
o
Z
Cl
~
><lE:
..:I"''''
'" '"
'" .,.
::>IDO
00""
.. '"
P:NO
Mo",
E-<
<(
~ID:>:
0'"
~O
ZNM
~';4~
~~Z
..:1....0
"'OZ
00
E-<
Z
M
~
o
U
...1Il
...0
......
0
N
......
N
...
MM
~f-<
..;..;
"'0
NN
"'N
"'N 0
..,r- 0
, ,
...r- ..,
<Dill ...
\0"" ,
, ..
, M
>< 00 :E
..:I \0\0 H
I>: ..,.., f-<..:I ..:I
M 0 >< 0
H :I: ..:I :I:
..:I f-< I>: f-<
~ rg~ M ~
..:I MM H
f-< 0 ZZ HIIl ..:I III Ul
MUl gJ 00 f-<'" ":>..:1'" M
:<M :I::I: 0 .., ,...
8:ii Ul "'''' 0 ..; 0
"':E ~~:ii Z
f-<":> '"
Z Z ~
Z .. 0 III 0
01>: Hr--~r--H~
HO Ul f.4r-t...,.Nf-tO
E-<E-< E-< ,:::( .. 0 .. ~ .. l/1 Ul
UU Z 0""'1""'00"1...,. E-<
MM ~ M SO~OSO;; Z
"'''' HZ~ M
UlUl 0 <D 0 , ~
~~ ~OO "'Ill ll'l f.l,IlIl m
UU HU 0 0 00 0
ZZ E-<...... ~o OC)OCO U
H H Q"'Ul ZN NZN
HHE-< H...... ......H......
ZE-< UlI>:S ~~&18~~~
o Z 10:: ~~Ul
HMo~ H.........~.......H........"'
f-4::EOCl) MM ::Jri~N::JN"""
U"'o '01>: IIlrl..:(r-lC!Jr-tlU
::>Oo~ E-<
0:: ~ I ~
E-<MOZ H
Ul;>r- ~"'~ d-
ZMoCl)
"" f-< OOoM
0 U U 'I>: a..Ul
Z~~"" ZUl ..:I
"" ';:i ~HM ..:I'"
"" o r-\O :z: I>: ":>..;
0 H ,'" H
.., !3 E-< ...0 ~
"'Ul (JUOO ~
M ..; ";H '0 SOO
-..:I r- "'00 MM III III
IIlM rot f-t~MO 1IlE-<E-< 00
O~ ~~~~~~ UlM , ............
~~ g~~ ,......
ri~~OOO '00
N O:E , ............
......E-< MO 'NN
NI>: I>: I>: I>:I>:U ,......
"'0 . III I>: .M '" ,
'" ZO III III ,
0 E-< .~ ,
M'" Ul -U , ... ...
~O gjE-<;:idjZ E-< 0 , 0 0
I>:~E-<MU..:I H Ul ,
a..>< ~ ...... ,
ME-< offi~i~g; '" , ... N
I>:H >< , ..:I ..:I
"'U ~E-<UOa....; '" E-< , III III
'D1I1
0
......
....
0
......
N
....
f>lf>l
t7...
<C<C
"'0
NN
"'N
"'N . 0
M.... , 0
, , I ..
........ , M
Cllll1 , ....
'D"" ,
, ..
, f>l
>< 00 , :t:
..:l 'D'D H
<>: MM .....:l
f>l 0
H :x:
..:l ...
~ t7<>:
..:l f>lf>l Z<C
... 0 ZZ HIII 00
f>lcn gj 00 ...'" f>l
:<:f>l :X::X: 0 ...
~~ 00 "'''' 0 0
"':t: Z
......, '"
Z 0
Z .. 0 1I1 ~
01>: H......,.
HO 00 t .........,.
...... ... , ,c:( .. 0 00
UU Z , 0.,. , ...
f>lf>l ~ f>l t SO~ Z
"'''' :t: , f>l
0000 HZ:t: , 0 Cll :t:
ZZ EOO t "'1I1 :t:
H H UU HU t 0 0
ZZ ......... , t70 U
H H OlloOO , ZN
HH", , H......
Z... OO<>:..:l I OOZ
o Z 10:: gjU::> , ..:lMf>l
HMr--tLo 0000 , H........:l
E-l~a(l) f>lf>l , ::>......:l
U"'o '0<>: , III....<C
::>Oo~ ,
I>:..:l 'f>l ... ,
...f>lOZ H !"~
oo~O ~~~
ZWco{J}
Cll 1-< 00....f>l
N U U .<>: "'00::>
00 ZOO
'D <C S~~~ t7Hf>l t..:l
.... <>: i2: I>: ,...,
0 H..:l ,'" H i-I
M !3 1-< 00 ~
....00 UCJoo
f>l <C <CH , 0 HOO
-..:l .... "'00 ::>f>lf>l
1I1f>l .... f-t::E:MO 1%11-<1-< '0
0t7 ~~~:s~~ OOf>l , ......
::.~ Of>l..:l ,....
......:l~01-<0 0::>'" '0
0 o:t: , ......
......... f>l0 'N
N<>: <>: <>: ~<>:u ,....
....0 . III <>: .f>l '" ,
Ilo zo III 1%1
0 1-< ~~
f>l'" 00 -u rl
<>:0 OO1-<<C ... 0 0
<C ~~~&l[j..:l H 00
Ilo>< ~ ......
f>l... O1J15i~g: '" ....
I>:H >< ..:l
IloU ~1-<UOllo<C '" 1-< III
~
o
Scale:
120'
5e 11 + Il V\: e. I C;OL,t r- 1-
1" = 120'
240' 360'
,
~0-.<"O~
OL Y fYJ PI<=-
HG1t5/J
1-
~
~
'-
~
11
"'-
~
....
~
'7'
~
~ ~ t
~ ~ ""i
~ ~ ~
~'~
~ ~
~
~ ~
~
~3. 7 3 -'
0\
~ '"
, ~
-..1 ...
,
103.73 I
"""""'II
~~~
~~;j
~~[)
~~~
:,\n~
~~~
,,~
Prescriptive Approach - Simple Form
For the Washington State Energy Code (2003 Edition)
Climate Zone 1
Lot: -=I/=- (
Address: I fo ( Au.ro"'-~ c +
City: port- Ar17d c.s
State: lJA. Zip: q o3fe 2 ~
Contact: .s u.. Z-L2/tJ? r:t 'lor
Phone: q-S 7 7':<-^"
Permit#:
Building Department Use Only
05 -16L.(
"i:~
Site Information
'Notes:
ice7.';""
,j:j',;,
. i ~ .. ~ I;'
':, ii. .:;~"
",""c;',,:,,', ..:"';
""",,,,,',.;,.:,.,...,i,;...
riP, );...' '~"'~~l'!~~': ",l
;"
:; :1;:, ~
~~ '~'~,:?\l!., ~,:d):,
Phone 2:
'to;
,- \' ,. ~1
'~l. ~;:il;ij ;j;~_~. ~l, 'Ii fl
:1;;: ~I
);. ',,:,;h.. ...
",-c' <;;"I':~~: ..'\i \'"
Fax:
"l;LLj~!lH~<.'" ~,"j.>, Ai, f;
,,~; '::~"H~;i;iI";_"r;~:ft i1rp:
.'- ,.J ''"'''''~''''',"< r.J i"- 0;
. '" ",,,,..i.. .;",",-.., _~ .' ...",'. :...
f;:1I~:.1' ~;>!I~}:'; ~!:l!;;l~, ,1;:ji1i ::~"iH~'I'n'h'iW';~;j ::; i:UPil;!b.~::;!;.;!~h
"~; 'ft!. :H. I.", ,': f', ~~.. : Ii!~;: ;n~ =: ',1 ,I;;", ~;:l; i1,;P::tl' ~~i! ~~,. ,'.';: ~,\; l:~;, !;'~,) '~::.' t:! L,o'; ..l';; u~ ,~'" q;f:l~t;' ,Hl;:i. '"
n Imlte azmg )J tlon nly)
Glazing Glazing U-Factor Door9 Wall Wall Wall Slab4
Option Area 10 U- Ceiling2 Vaulted Above Int4 Ext4 Floors On
% of Floor Vertical Overhead I I factor Ceiling3 Grade Below Below Grade
Grade Grade
III Unlimited
Group R-3 OAO 0.58 0,20 R-38 R-30 R-21 R-21 R-IO R-30 R-lO
Occupancy
Only
Table 6-1
PRESCRIPTIVE REQUIREMENTS 0,1 FOR GROUP R OCCUPANCY
CLIMATE ZONE 1
(U r ' d GI ' O' 0 I )
See the code text for footnote references
This project complies with the following:
,/ The project is a single family residence or duplex.
,/ The project is wood frame OR all of the insulation is interior or exterior of the framing.
,/ All building components meet the requirements listed in Table 6-1, Option III.
,/ The project will meet all other provisions of the WSEC and VIAQ.
The project will take advantage of the following exceptions to the prescriptive option:
o 602.6 Exception 1. One door, that is 24 ft.2 or less, that does not meet the standards is allowed,
Location of the door taking this exception
o 602.6 Exception 2. Doors with a U-factor of 0.40 allowed without calculations, Option III only.
Location of the door(s) taking this exception
Copyright 2002. WSUCEEP02-056
Copied by permission from the Washington State University Extension Energy Program
Prescriptive - Simple Form - Climate Zone 1
7/26/2004
-..
~~o~
.$'HING"
'Vashington State Energy Code
Plan Review Checklist
Applicant please Check. write in N/ A. or fill in value on boxes or lines,
Project Address: Ii c> f
Au.rvrtL C1-.
Compliance Approach:(check one) 0 Systems analysis
o Component perfomlance }(Prescriptive path
REA TING SYSTEM
o Zone Heating ~Electric Fumace
DHeat Pump
FOUNDATION PHASE
o Slab R- _ Exterior down to ii'ostline/slab bottom; Interior 24" horizontal or vertical; or, If radiant under entire slab
o Below grade exterior wall insulation: R- _ (If interior -see Insulation Phase)
FRAMING PHASE
W'Standard 0 Intermediate 0 Advanced
j8:'Standard air seal: sole plate/sub floor; rim joist; window & door frames; wires, plumbing, ducts, light fixtures
fJK SOUIce specific exhaust fans: bath & laundry(50 cfm) kitchen(lOO cfm)
~ Whole house exhaust fan _ cfm intern-rittent system has manual & auto controls: Outdoor air supply reg. for habitable rooms
or
o Integrated forced -air system, fal1_ dm, outside air duct(with motor damper) allowing .35 and .5 ACH
INSULA nON PHASE
o R-U Wall insulation(above grade)
o R-U Wall insulation(below grade): Interior wall insulation
DR-3D Floor insulation
o R~ Ceiling insulation: Including attic hatch
o R3JL Vaulted Ceiling insulation
o Vapar retarders: Walls, Ceiling: 0 4 mil poly MPerrn rated paint Okraft faced batts
o Vapar retarders: Floors: 0 4 mil poly Dkraft faced batts
'$.Ground cover: 6 mil Black polyethylene, 12" lap at joints & extending to foundation wall
T:\ROGER\BLDG-FORMS-BROCHURESIE-I\'ERGYPLANREVIEW
Over: Fill in back side also,
r'
BUILDING PERMIT - APPLICATION /~
Fill out COMPLETELY and in INK. Your application and site plan MUST it /
COMPLETE to be accepted for review. If you have any questions, cali-f1
PERMITS (360) 417-4815 FAX(360)417-4711 j/
FOR OFFICIAL USE ONLY:
Date Rec.: 9- 30 - oS
Permit #: {)!3 -1&1{;-
ate Approved: cJ~
Date Issued: '
. .
Applicant or Agent: ~ I(~ ~. Phone: 3{ao/ t' bC; -ol../Ll- c./
Owner: ()(l.{ nL.pIL UFlt1 OeVe..lqoV710?f- Phone: l{s 1-- 7U z....
Address: p.O. Box ,<5&[5 City: {t:b..../~.b?r~ WA Zip: c;l32..V
Architect/En,gineer: Phone: ffoq ---044- S
I. "Yt/lQ _ f ,_ f -.i...-.,A w.{AJT;1q II / ~ C
Co~ctor---L\C'T7tJ,., LCV1~7H.('L.71PYJStateLicense#: q~.l..13..3 Exp: /.:27!j)b Phone: (jl() /-3Q92......
Address: fo. Box 1'f2S City: $;e1 uJI'n W A Zip: 'r 0 .3 g ~
PROJECT ADDRESS: ILIa I AUfz>rA.. C+- ZONING: RSCj'
LEGAL DESCRIPTION: Lot::Jt 7 Block: Subdivision: 01 y Yh I'lL, /{e.iqh~
CLALLAM COUNTY PARCEL NUI\.1BER:
Credit Card Holder Name:
Billing Address:
Credit Card Type VISA MC #
,!~E OF WORK: SIZEN ALUATION:
pi(.Residential ~New Constr, 0 Re-roof 0 Stove /7 Do SF, @ $ 10D /SF, = $
o Multi-family 0 Addition 0 Move 0 Garage ~ SF. @ $ ,~D /SF. = $
o Commercial 0 Remodel, 0 Demolition 0 Deck 170 SF. @ $;2.() /SF, = $
D Repair 0 Sign 0 OtheI_ tlOTAL VALUATION $
BRIEF DESCRIPTION OF THE PROJECT: 5: (/it:) (p fl;t.-t7l-1( 't rCS/danCR I/)
tluJdo.oYJ1eJZT of 32 home.S
,
COMMERCIAL/RESIDENTIAL: Occupancy Group:
No, of Stories: -L Lot Size: Cf'oo ~ Existing Sq, Ft. 0
Total lot coverage ?-7 %
City:
Exp. Date:
170, tJCl). Dl>
~~
I 0;. ,:2w .....;
Occupant Load: Construction Type:
& Proposed Sq. Ft..:2.3 ~ K = TOTAL Sq, Ft..2.3? 8
APPROVALS:
PLAN:
BLDG:
DPWU:
FIRE:
OTHER:_
PLANNING USE ONLY:
ESAlWetland(s): DYes 0 No SEPA Checklist required? 0 Yes 0 No Other:
BUILDING PERMIT APPLICATION SUBMITTAL: The Building Division can provide you with information on the application and
plan submittal requirements if you have questions,
VALUATION OF CONSTRUCTION: In all cases, a valuation amount must be entered by the applicant. This figure will be reviewed
and may be revised by the Building Division to comply with current fee schedules, Contact the Permit Coordinator at 417 -48 15 for assistance,
PLAN CHECK FEE: IF a plan check fee is due it must be submitted at the time the building permit application and construction plans are
submitted. All other permit fees are due at the time of permit issuance,
EXPIRATION OF PLAN REVIEW: 1fno permit is issued within 180 days of the date of application, the application will expire. The
Building Official can extend the time for action by the applicant up to 180 days upon written request by the applicant (see Section Rl 05.3.2
of the International Building/Residential Code, 2003). No application can be extended more than once,
I hereby certify that I have read and examined this application and know the same to be true and correct. I am authorized to apply for this permit and
understand that it is my responsibility to determine what permits are required ,not the City's, and that must obtain such permits prior to work.
T:\RVESS\BLDG-forms-brochures\2003-Buildingpermit.wpd Applicant: ~ ~~ Date: 7/:xI as-
~
Fire Sprinkler System Plan
"
Innovated Fire
Sprinkler Systems
81 New Haven Lane
Port Angeles, WA., k~
98362 ~ \)~.; ~
(360) 452-7583
February 7, 2006
For: Want Action Construction
P.O. Box 1425
Sequim, WA. 98382
Location: 1401 Aurora Court
Port Angeles, WA., 98362
12.
13.
14.
1'5.
F p- 9 C
..
'-I'.i'
,
l~JJ ttrUKAULIC .CALC~ATION~.
Worksheet
For 1" CPVC Pipe
't
Two heads require 26 gpm flow at designed pressure. [+ 5 gpm domestic u~
One head requires 18 gpm flow at designed pressure.
1.
2.
3.
4.
5.
~ ~
Pipe site = 11- J CPVC (friction loss .1067). "
Water pressure at street (2/ = ~S psi.
Meter friction loss (3) = " psi (see Table 4..4.3d NFPA 13/
(2) G S minus (3) , 9 (4) - s-G psi remainir
L~ss from street main to control valve = 70 feet X , .106T I = 2. ~II
feet (see friction loss chart).
(4) ~~ (;.' m~nus (5)' 7, '-1) - = (6) Lf 8. S.:]
Elevation loss (building & street) = : J 2. feet X .434 =
(6) <--18, S.J minus (7) S.. 2 I: . _'-I 3. ~?2-
Total length of pipe from control valve to the farthest sprinkler =
X I ."10671 = 0j ~ q I psi.
(8) ,- '-I 3.. 12 minus (9) 1-/, '7 ," _ .s 8, ~l) psi remarnrn!
Equivalent length for valves and fittings(m~ter to fa~hest sprinkler head):
Type Number Eauivalent
1 " T run 8 X m =
1" T Branch -3' X m =
1" 90 Elbo.w 3 X W =
1" Coupling I X m =
1" 45 Elbow 0 X IT] =
1" Gate Valve / X IT] =
(11) To~al Feet LJ G
6.
7.
8.
9.
psi remainin(
~. 2.,/ p~
psi remainin
'-I b fe
10.
11.
8
IS
2-/
/
o
/.
f
f ~
fee~~~'\"
~~t1clJ~
Loss in fittings (11) '--I G feet X '.1067' _ L/, CZ I ps.'
(10) :I 8. '1/ . TDinus (12) L"l. 7 I _ 33, SO psi remaining
PSI remaining (13) .3 J.S 0 minus 3, i.f (loss in riser) parts = SO ./0 .
(14) .3 0 ~ to is more than the minimum, design psi required for 2 or 1 sprinkler
heads operating.
Riser Parts
Potter flow switch 2.4 psi
Soft seat valve 1.0 psi
Needed Information:
Type of sprinkler head L
GPM & pressure 1 st head I
GPM & pressure 2nd head Cb .
3/4" water meter or no)
Revised 5/29/91
.. ",:
. f '. '~'. J-:" . ,.' .', . ..' .,.'...... _ . . ... .
f:,: '.:'. , . :..Sp:R-1N.K:L.:E.R..... .MA,N \ I="OL 0
. '
~
. ~
.-
. .
.....-. -..-.--... -- -.-. --- .... . ~
- pvc - >
--' .-... .....-..-.--. ....
. ._ To ..J-:l..EAD~ ., ,
.-............. --.......- .....-.. -.-."
. .. ...-. .. ..- .-. ..'-. .... .-..-.....- - ..-.- ~ -. ....
--.-. --- ... .--- -_.-_._..__._.-~. .-..--.-.--..---- -.-. --.. - ...
~/~ ~~.I ~.~__ ._____
- -.--. -- ..-....-. .-- -... . --------.--- .--.-., ... --- - ".-.
.__ __ __ ..__ _.. ... _ . ._... h.. .. ... ... .--.. - ._- . .. .
~ '
.:.... . - .... .-- -... ....-.--- ~ - .-. .... ,. . . '. ~' ""- . R. -. '-" .:.-;.. .. ..... .
.~.~.. . """ .____ ,_ '.__,__ ._ .__..._._. . ... () .A.Il\t R.\.l::.ST..VALV
I. . .. .. ." '. . ,... . _ ._..__.._. . ..- .--- - .. .(PL.Vl\f\B.l;.O .TO., OVT,s/.DE.)
.' ___ ._._.._ ._.. .._ __'. .n,,_ ....__.. .._._.. ... . _. .. .. ...-
~~l< :. .'
I.\J.~...... ._
.... . ___E.l;O_\!~L._SW_LT.~H_ -. ,- -... ,. .
. .._ . ._._.___.. ...._h____.______.._. -.. .... .-..
-. . . . -.- ... - - . - . .--..- -- . . . - - - .... .. .. ...
.- . -..--..---.--.-.--..------..--...- -.. .-.__.-.--_._-.. .--. -------.-.-
. .
'"--.---.. ..-.. -..--.-...--.......-.---. .._- .-.. -.... ----.. -. ..-..-.. .-...---..--------.-. -_.- .---. .----.. .... ..
.-.. 0
1.0_.. _n.... _.
. .
; -
, .- .". :-\ -- ...----,------.--------. .
.-------....-..--- ....- .....-....--..--.---.- -----.-- .-
.
.
. . . - . . ..- .-. -....
.. . . .
.-.. --- ::e~-. ~ I .-.... . ..; ~~n~ u. .,. - .. . ---.. - -,,'--' " .'
..' _.. ;,~..~:... ~ ~Jq I 6 r - .. .,__ '~G~ r.. __'_n' _.h.__ ._ ..... ' . .
'--'--'" ............-.... -- ~.., -'. .---_. .-' ...., .
.- ._...__ ,._ .... 1..' (..P\.P€. .' .
.
.._- --.....- .,. ----.--. .-.-. -.. --. -. -;---_. -... ---...-....... '-"'- .. - -
=-S.l.G:N~ D ....BY.:._. ..__.;. . ..:. ._.. .. ..: """ ..,.. ... ... ..'--" ..'. ..' - . '.'
. .. __. _ _.. ._ . __. _. .......,.' _.._ .... .... _. .. . . '" _.. ..' F ~OJY\ . ...
f\!f\lOVATED F,\,RE.., S.?,R\l\\KLERS. __.......,_,.:lY'E1E..~:~.._
'). .
~ ..
~T ..
. \to
.....1 . '
3
. . ,
tqeD / Fire & Building
/ Products
Direct Sales (Central): Tel: (800) 523-65121 Fax: (215) 362-5385
Distribution Sales (Gem/Star): Tel: (800) 558-52361 Fax: (800) 8n-1295
Technical Services: Tel: (800) 381-93121 Fax: (800) 791-5500
,-
Series LF" Residential
Concealed Pendent Sprinklers, Flat Plate
4.2 K-factor
General
Description
The Series LFII (TY2596) Residential
Concealed Pendent Sprinklers are
decorative, fast response, fusible sol-
der sprinklers designed for use in resi-
dential occupancies such as homes,
apartments, dormitories, and hotels.
The cover plate assembly conceals the
sprinkler operating components above
the ceiling, The flat profile of the cover
plate provides the optimum aestheti-
cally appealing sprinkler design. In ad-
dition, the concealed design of the Se-
ries LFII (TY2596) provides 1/4 inch
(6,4 mm) vertical adjustment. This ad-
justment reduces the accuracy to
which the fixed pipe drops to the sprin-
klers must be cut to help assure a
perfect fit installation.
The Series LFII are to be used in wet
pipe residential sprinkler systems for
one- and two-family dwellings and mo-
bile homes per NFPA 13D; wet pipe
residential sprinkler systems for resi-
dential occupancies up to and includ-
ing four stories in height per NFPA
13R; or, wet pipe sprinkler systems for
the residential portions of any occu-
pancy per NFPA 13.
The Series LFIl (TY2596) has a 4.2
(60,5) K-factor that provides the re-
quired residential flow rates at reduced
pressures, enabling smaller pipe sizes
and water supply requirements.
The Series LFII (TY2596) has been
designed with heat sensitivity and
water distribution characteristics
proven to help in the control of residen-
tial fires and to improve the chance for
occupants to escape or be evacuated.
The Series LFII (TY2596) Residential
Concealed Pendent Sprinklers are
shipped with a Disposable Protective
Cap. The Protective Cap is temporarily
removed for installation, and then it
ca~ be repl?ced to help protect the
spnnkler while the ceiling is being in-
Page 1 of 4
stalled or finished. The tip of the Pro-
tective Cap can also be used to mark
the center of the ceiling hole into pias-
ter board, ceiling tiles, etc. by gently
pushing the ceiling product against the
Protective Cap. When the ceiling in-
stallation is complete the Protective
Cap is removed and the Cover Plate
Assembly installed.
WARNINGS
The Series LF/! (TY2596) Residential
Concealed Pendent Sprinklers de-
scribed herein must be installed and
maintained in compliance with this
document, as well as with the applica-
ble standards of the National Fire Pro-
tection Association, in addition to the
standards of any other authorities hav-
ing jurisdiction. Failure to do so may
impair the integrity of these devices.
The owner is responsible for maintain-
ing their fire protection system and de-
vices in proper operating condition.
The installing contractor or sprinkler '
manufacturer should be contacted
relative to any questions.
Sprinkler !Model
Identification'
Number
SIN TV2596
Technical
Data
Approvals:
UL and C-UL Listed.
Maximum Working Pressure:
175 psi (12,1 bar)
Discharge Coefficient:
K = 4.2 GPMlpsi112 (60.5 LPMlbarl12)
Temperature Ratlng~
160oFn10C Sprinkler with
1350F/570C Cover Plate
.JULY, 2002
-
--'--.--~~~.:. .
;:~~,~,),~~,
..,~ .\.,.._ . ;Z:"~"":'{:':;::(':';"-.:.-';"
Vertical Adjustment:
1/4 inch (6,4 mm)
Finishes:
Cover Plate:
Rat White, Bright White, Chrome, or
Custom
Physical Characteristics:
Body _ . . , . . . . . .
Cap. . . . , . _ , . . , . .
Saddle . , . . . , . . . . .
Sealing Assembly . . , . . .
. . . . , Beryllium Nickel wI Teflont
Soldered Link Halves . Nickel
Lever . . . . . . ... . . . . . Bronze
Compression Screw . . . , . . Brass
Deflector . . . . , , . . , . _ Bronze
Guide Arm Frame , . . . . . Bronze
Guide Arms . Stainless Steel
Support Cup . . . . . . _ . ., Steel
Cover Plate ,...,.... Copper
Retainer . . , . . . . . . . . . Brass
Cover Plate Ejection Spring ....
. . . . . . . . . . , , Stainless Steel
. Brass
Bronze
. Brass
tDuPont Registered Trademark
TFP440
'.
. ... . .
. .,
~: -)>.ge 2 of .4
,. .
c'....' ."
Operation
When exposed to heat from a fire, the
Cover Plate, which is normally sol-
dered to the Support Cup at three
points, falls away to expose the Sprin-
kler Assembly. At this point the Deflec-
tor supported by the Arms drops down
to its operated position. The fusible link
of the Sprinkler Assembly is com-
prised of two link halves that are sol-
dered together with a thin layer of sol-
der. ,When the rated temperature is
reached, the solder melts and the two
link halves separate allowing the sprin-
kler to activate and flow water.
Design
Criteria
The Series LFII (TY2596) Residential
Concealed Pendent Sprinklers are UL
and C-UL Usted for installation in ac-
cordance with the following criteria.
NOTE
When conditions exist that are outside
the scope of the provided criteria, refer
to the Residential Sprinkler Design
Guide TFP490 for the manufacturer's
recommendations that may be accept-
able to the Authority Having Jurisdic-
tion.
System Type. Only wet pipe systems
may be utilized.
Hydraulic Design. The minimum re-
quired sprinkler flow rate for systems
designed to NFPA 13D or NFPA 13R
are given in Table A as a function of
temperature rating and the maximum
allowable coverage areas. The sprin-
kler flow rate is the minimum required
discharge from each of the total
number of Odesign sprinklers" as speci-
fied in NFPA 130 or NFPA 13R
For systems designed to NFPA 13, the
number of design sprinklers is to be
the the four most hydraulically de-
..manding sprinklers. The minimum re-
quired discharge from each of the four
sprinklers is to be the greater of the
following: ,
· The flow rates given in Table A for
NFPA 130 and 13R as a function of
temperature rating and the maxi-
mum allowable coverage area.
· A minimum discharge of 0,1 gpm/sq,
ft. over the "design area" comprised
of the four most hydraulically de-
manding sprinklers for the actual
coverage areas being protected by
the four sprinklers.
Obstruction To Water Distribution.
Locations of sprinklers are to be in
~
TFP440
y
Minimum Flow (b) and Minimum Flow (b} and
Maximum Maximum Residual Pressure Residual Pressure
Coverage Spacing For HorIzontal Ceiling For Sloped CeIling
Area (al Ft. (Max. 2 tnch Rise (Max. 8 Inch Rise
Ft.xFt. (m) for 12 Inch Run) for 12 Inch Run)
(m x m)
1600Fm oC 160oFmoC
Sprinkter Sprinkler
12 x 12 12 13 GPM (49,2LPM) 18GPM (68,1lPM)
(3,7 x 3,7) (3,7) 9.6 psi (0.66 bar) 18.4 psi (1,27 bar)
14 x 14 14 14 GPM (53,0 LPM) 18 GPM (68,1lPM)
(4,3 x 4,3) (4,3) 11.1 psi (0,77 bar) 18.4 psi (1,27 bar)
/'IOXH:i J 16 16 GPM (60,6 LPM) 18 GPM (68.1lPM)
(4,9 x 4,9) (4.9) 14.5 psi (1.00 bar) 18.4 psi (1:2.7 bar)
'- 1A}( 1R...o""" 18 20 GPM [15,7 LPM) N1A
(5,5 x 5,5) (5,5) 22.7 psi (1.57 bar)
2Ox2O 20 24 GPM (90,8 LPM) N1A
(6,1 x 6,1) (6.1) 32.7 psi (2,25 bar)
(a) For coverage area dimensions less than or between those indicated, it is
necessary to use the minimum required flow for the next highest coverage area
for which hydraulic design criteria are stated.
(b) Requirement is based On minimum flow in GPM (LPM) from each sprinkler. The
associated residual pressures are calculated using the nominal K-factor. Refer to
Hydraulic Design Criteria Section for details,
TABLE A
NFPA t3D AND NFPA t3R HYDRAULIC DESIGN CRITERIA
FOR THE SERIES LFII (TY2596)
RESIDENTIAL CONCEALED PENDENT SPRINKLER
accordance with the obstruction rules
of NFPA 13 for residential sprinklers.
Operational Sensitivity. The sprin-
klers are to be installed relative to the
ceiling mounting surface as shown in
Figure 3.
Sprinkler Spacing. The minimum
spacing between sprinklers is 8 feet
(2,4 m), The maximum spacing be-
tween sprinklers cannot exceed the
length of the coverage area (Ref. Table
A) being hydraulically calculated (e,g.,
maximum 12 feet for a 12 ft. x 12 ft.
coverage area, or 20 feet for a 20 ft. x
20 ft. coverage area).
Installation
The Series LFII (TY2596) must be in-
stalled in accordance with the follow-
ing instructions:
NOTES
Damage to the fusible Link Assembly
during installation can be avoided by
handling the sprinkler by the frame
arms only (i.e., do not apply pressure
to the fusible link Assembly).
A leak tight 1/2 inch NPT sprinkler joint
should be obtained with a torque of 7
to 14 tt-ibs. (9,S to 19,0 Nm). A maxi-
mum of 21 tt.lbs. (28,S Nm) of torque
is to be used to install sprinklers.
Higher levels of torque may distort the
sprinkler inlet with consequent leak-
age or impairment of the sprinkler.
Do not attempt to compensate for in-
sufficient adjustment in an Escutcheon
Plate by under- or over-tightening the
Sprinkler. Readjust the position of the
sprinkler fitting to suit.
Step 1. The sprinkler must only be
installed in the pendent position and
with the centerline of the sprinkler per-
pendicular to the mounting surface.
Step 2. Remove the Protective Cap.
Step 3. With pipe thread sealant ap-
plied to the pipe threads, and using
the W- Type 18 Wrench shown in Figure
2, install and tighten the SprinklerlSup-
port Cup Assembly into the fitting. The
W-Type 18 Wrench will accept a 1/2
inch ratchet drive.
Step 4. Replace the Protective Cap by
pushing it upwards until it bottoms out
against the Support Cup, The Protec-
tive Cap helps prevent damage to the
Deflector and Arms during ceiling in-
stallation and/or during application of
-..,
."~ 1.,.' . . ,
. . . ". TFP440
~. \....
4 ..
. .
BODY
(112' NPl)
CAP
SADDLE
GUIDE
ARM
GUIDE ARM
FRAME
I I
I I
I I
I I
I I
~ I I
"'.... I I
,J LJ" "'-..J L,
L....._.,;----....I"""--""""-....."J
SPRINKLERlSUPPORT CUP
ASSEMBLY
THREAD INTO
SUPPORT CUP
UNTIL MOUNTING
SURFACE IS
FLUSH WITH
CEILING
o
o
SOLDER
TABS (3)
COVER PLATElRETAINER
ASSEMBLY
FIGURE 1
SERIES LFII (TY2596) RESIDENTIAL
CONCEALED PENDENT SPRINKLER
FACE OF
SPRINKLER
FITTING
1-718'%118'
(47,6 mm
%.3,2 mm)
COVER- SPRINKLER-
RETAINER SUPPORT CUP
ASSEMBLY ASSEMBLY
3-114' DIA,
(82,6 mm)
=', MOUNTING
3116' J SURFACE
(4,8 mm)
Page 3 of 4
s
"
SEAUNG
ASSEMBLY
WRENCH
RECESS
SPRINKLER
WRENCHING
AREA
D
COMPRESSION
SCREW
PUSH WRENCH
IN TO ENSURE
ENGAGEMENT
WITH SPRINKLER
WRENCHING AREA
LEVER
FIGURE 2
W-TYPE 18
SPRINKLER WRENCH
DEFLECTOR
(OPERATED
POSITION)
RETAINER
WITH THREAD
DIMPLES
EJECTION
SPRING
COVER
PLATE
SPRINKLER-
SUPPORT CUP
ASSEMBLY
OPERATED
SPRINKLER
COVER
PLATE
RETAINER
~
~
718' (22.2 mm)
1-118' (28,6 mm)
TIP
DEFLECTOR IN
OPERATED POSITION
1
FIGURE 3
SERIES LRI (TY2596) RESIDENTIAL CONCEALED PENDENT SPRINKLER
INSTALLA TlON DIMENSIONS / PROTECTIVE CAP / ACTIVA TED DEFLECTOR
:"t ., .
: v. ...,
, . ": ~ilge 4 of 4
-,.
.. ':..
the finish coating of the ceiling. It may
also be used to locate the center of the
clearance hole by gently pushing the
ceiling material against the center
point of the Cap.
NOTE
As long as the protective Cap remains
In place, the system is considered to
be "Out Of Service"..
Step 5. After the ceiling has been com-
pleted with the 2-1/2 inch (63 mm)
diameter clearance hole and in prepa-
ration for installing the Cover Plate As-
sembly, remove and discard the Pro-
tective Cap, and verify that the
Deflector moves up and down freely.
If the Sprinkler has been damaged and
the Deflector does not move up and
down freely, replace the entire Sprin-
kler assembly. Do not attempt to mod-
ify or repair a damaged sprinkler.
Step 6. Screw on the Cover Plate As-
sembly until its flange comes in con-
tact with the ceiling.
Do not continue to screw on the Cover
Plate Assembly such that it lifts a ceil-
ing panel out of its normal position.
If the Cover Plate Assembly cannot be
engaged with the Mounting Cup or the
Cover Plate Assembly cannot be en-
gaged sufficiently to contact the ceil-
ing, the Sprinkler Fitting must be repo-
sitioned.
Care and
Maintenance
The Series LFII (TY2596) must be
maintained and serviced in accord-
ance with the following instructions:
NOTES
Absence of an Escutcheon Plate may
delay the sprinkler operation in a fire
situation.
Before closing a fire protection system
main control valve for maintenance
work on the fire protection system
which it controls, pennission to shut
down the affected fire protection sys-
tem must be obtained from the proper
authorities and all personnel who may
be affected by this action must be no-
tified.
Sprinklers which are found to be leak-
ing or exhibiting visible signs of corro-
sion must be replaced.
Automatic sprinklers must never be
shipped or stored where the tempera-
ture will exceed 100oF/380C and they
must never be painted, plated, coated,
or otherwise altered after leaving the
factory. Modified or over heated sprin-
klers must be replaced.
~,
Care must be exercised to avoid dam-
age - before, during, and after instal-
lation. Sprinklers damaged by drop-
ping, striking, wrench twisVslippage,
or the like, must be replaced.
The owner is responsible for the in-
spection, testing, and maintenance of
their fire protection system and de-
vices in compliance with this docu-
ment, as well as with the applicable
standards of the National Rre Protec-
tion Association (e.g., NFPA 25), in
addition to the standards of any other
authorities having jurisdiction. The in-
stalling contractor or sprinkler manu-
facturer should be contacted relative to
any questions.
NOTE
The owner must assure that the sprin-
klers are not used for hanging of any
objects and that the sprinklers are only
cleaned by means of gently dusting
with a feather duster; otherwise, non-
operation in the event of a fire or inad-
vertent operation may resuh.
It is recommended that automatic
sprinkler systems be inspected,
tested, and maintained by a qualified
Inspection Service.
Limited
Warranty
Products manufactured by Tyco Fire
Products are warranted solely to the
original Buyer for ten (10) years
against defects in material and work-
manship when paid for and properly
installed and maintained under normal
use and service. This warranty will ex-
pire ten (10) years from date of ship-
ment by Tyco Fire Products. No war-
ranty is given for products or
components manufactured by compa-
nies not affiliated by ownership with
Tyco Fire Products or for products and
components which have been subject
to misuse, improper installation, corro-
sion, or which have not been installed,
maintained, modified or repaired in ac-
cordance with applicable Standards of
the National Fire Protection Associa-
tion, andlor the standards of any other
Authorities Having Jurisdiction. Mate-
rials found by Tyco Fire Products to be
defective shall be either repaired or
replaced, at Tyco Rre Products' sole
option. Tyco Fire Products neither as-
sumes, nor authorizes any person to
assume for it, any other obligation in
connection with the sale of products or
parts of products. Tyco Fire Products
shall not be responsible for sprinkler
system design errors or inaccurate or
incomplete information supplied by
Buyer or Buyer's representatives.
TFP440
G
IN NO EVENT SHALL TYCO FIRE
PRODUCTS BE LIABLE, IN CON-
TRACT, TORT, STRICT LIABILITY OR
UNDER ANY OTHER LEGAL THE-
ORY, FOR INCIDENTAL. INDIRECT,
SPECIAL OR CONSEQUENTIAL
DAMAGES, INCLUDING BUT NOT
LIMITED TO LABOR CHARGES, RE-
GARDLESS OF WHETHER TYCO
FIRE PRODUCTS WAS INFORMED
ABOUT THE POSSIBILITY OF SUCH
DAMAGES, AND IN NO EVENT
SHALL TYCO FIRE PRODUCTS' LI-
ABILITY EXCEED AN AMOUNT
EQUAL TO THE SALES PRICE.
THE FOREGOING WARRANTY IS
MADE IN LIEU OF ANY AND ALL
OTHER WARRANTlESEXPRESSOR
IMPLIED. INCLUDING WARRANTIES
OF MERCHANTABILITY AND FIT-
NESS FOR A PARTICULAR PUR-
~
Ordering
Procedure
When placing an order, indicate the full
product name. Contact your local dis-
tributor for availability..
Sprinkler Assembly:
Series LFII (TY2596), K=4.2, Residen-
tial Concealed Pendent Sprinkler with-
out Cover Plate Assembly,
PIN 51-122-1-160.
Cover Plate Assembly:
Cover Plate Assembly having a (spec-
ify) finish for the Series LFII (TY2596),
K=4.2, Residential Concealed Pen-
dent Sprinkler, PIN (specify).
Chrome. . . . . . , . . , . . , , . . ., PIN 56-122-9-135
~htVVhtte......,........ PIN 56-122-4-135
Rat VVhite .............. .. PIN 56-122-5-135
Custom ..... .... .... .. ... PIN 56-122-X-135
Sprinkler Wrench:
Specify: W-Type 18 Sprinkler Wrench,
PIN 56-000-1-265,
TYCO ARE PROOVCTS, 451 Nonh Cannon Avenue, Lansdale, Pennsylvania 19446
,O't
-
.~ . . .
- .
. ~...
.-.
. .'.....
.....
"',
@
~POTTER
BELLS
PBA-AC & PBD~DC
Potter Electric Signal Company
2081 Craig Rdo/P.O. Box 28480
S1. Louis, MO 63146 '
(314)878~3211 (800) 325-3936
. .: "'~
....
Potter Electric Signal & Mfg. 1. TO
1967 Leslie Street -
Don Mills, Ontario, Canada M382M3
(416) 441-1833
UL USTED, FM APPROVED
Sizes Avallable:G:) 8-, and 10-
Voltages Available: ~
(I2QVAG)
12VOC (10.2 to 1506) Polarized
24VOC (20.4 fo 31.2) Polariz~d
Service Use: Rre Alarm
General Signaling
Burglar Alarm
Environment: Indoor or Outdoor Use (See Note 1)
-400 to 1500F (outdoor use require
weatherproof bacl<box)
Termination: 4 No. 18 AWG stranded wires
i ~~.;'j :,.J~~:1ll~~~~~L .
, . ,. .,' , ,':, 4i~'t~tl~ "... ". ,.... '.
..~. : <~ ;)~~j{':?:~'-~'~:.~ ~~:~~~~~ .:: ........~: ;~::~}/.: .....~::-::..
. '. '.' .~. ~....,:...;c:,r..,:..:J;:r.~.,.,~ '':' . '. .-' . . ....
",::, .'..;::2~.(.~.,\ ~~~~1?~?;.):':<';'~3:1A':'/',,,:,.:,:,,~~;::,,;: ...
,.., '..." ...,. ...."f~."'.. . .::::c;K'~ '" ,....
.00 0::, . .~:. >.~.~,;.::'_ .. ~~~",.~t~~._.. ....~.~i?~~:f:.\J :70,: :... ":: .~ Of
. .: t".. '.";. ..... . ,', .~...-':.~"""'..'~":\'. .;..\q~f;j\ J~ .~-."..'.'... '.' ..
....
6" BELL Sl10WN
Finish: Red powder coating
Optional: Model BBK-l weatherproof backbox
fhese vibrating type bells are designed for use as fire. burglar. or general signaling devices. They have low power
::onsumption and high decibel ratings. The unit mounts on a standard 4- square electrical box for indoor use. or 00 a model
38K-1 weatherproof backbox for outdoor applications.
ALL DC BEllS ARE POLARIZED AND HAVE BUILT-IN TRANSIENT PROTECTION:
StZE TYPICAL dB MINIMUM dB
VOLTAGE MOOEL NO. STOCK NO. CURRENT (MAX) c 10 FT. C 10 FT_
6 l2VOC PBOl26 1706012 _12A 85 75
8 12VOC PBOl28 1706012 .12A 90 75
10 12VOC PB01210 1710012 _12A 92 75
6 24VOC PB0246 1706024 .06A 87 75
8 24VOC PB0248 1706024 _06A 91 79
10 24VOC PB02410 1710024 .06A ~ 79
6 24VAC PBA246 1806024 .17A 91 75
8 24V AC PBA248 1808024 _17A 94 75
- 10 24V AC PBA2410 181002-4 .17A 94 75
~ 6 120VAC PBA 1206 1806120 _OSA 92 82
8 120VAC PeA 1206 1806120 .OSA 99 82
10 120VAC PBA12010 1610120 _OSA 99 85
Weatherproof backbox model 88K.l Stk. No. 1SOOOO1.
<coe.,s:
I. e.cinimum d8 '~I"'9s ale ~lcuUl"d Io-om integraled sound p<essure measurements made at U__..,.. Labotalories as ~... Ul. Sla...s..ld 46-4. UL
1lempe1~IUf" I~nge is .:JO- 10 I SO'f.
~. TrP'c" csa 'al"'O~ ale cal(;u1~I~ II.,.... tn<!.SU<~s made...-. a c.onvenIional sound IeveC mele< and afe indc....... of 0UCpuI levees... an actual instatUloO<'.
'RINTEO IN USA
-
MKT. <<8850001- REV K
PAGE 10F2
'"\. .
.,. .. .,.
.... ....
. , . .... .,
.., . .
(e).POTIER
Potter Electric Signal Company
2081 Craig Road · P,O, Box 28480
St. Louis, MO 63146-4161
(314) 878-4321 .. (800) 32~936
{
G)
FOR SMALL PIPE
VSR-SF
VANE lYPE WATER FLOW
ALARM SWITCH WITH RETARD
Potter Electric Signal & Mfg. L TO
1967 Leslie street
Don Mills, Ontario, Canada M382M3
(416) 441-1833
STK. NO. 1113000
U.S. PAT. NO. 3921989, CANADIAN PAT_ NO_ 1009680
OTHER PATENTS PENDING.
Ul., ULC, CSFM USTED and NYMEA ACCEPTED
Secvfce Pressure: Up to 2SO PSI
Minimum Row Rate for Alann: 10 GPM
Maximum Surge: 18 FPS
Enclosure: ~ red enamel finish
Cover held in place with tamper resistant screws
Contact Ratings: 2 sets of SPOT (Fonn C)
15.0 Amps at 1251250 VAC
2.0 Amps at ().3() VOC
Conduit Entrances: 2 knockouts provided fof 112:' cooduit
Usage: Usted Plastic. Copper and Schedule 40 Iron Pipe
Fits pipe sizes -1"" 1 U4", and 1112:'
Note: 8 paddles are furnished with each unit. one for each
pipe size of threaded or sweat TEE. one for 1" CPVC.
and one for 1112" poIybutyIene (CTS~ppertubing size)
environmental Specifications:
Suitabte for indoor or outdoor use with factory installed
gasket and die-cast housing.
NEMA 4 Rated Eodosure -use with appropriate conduit fitting.
Temperature Range: 40" F/l20" F (4.5" Cl49" C)
Caution: This device is not intended for applications in
explosive environments
Service U=
Automatic Sprinlder NFP A-13
One or two family dwelling NFPA-130
Residentiar'occupancy up to four stories NFPA-13R
National Fcre Alarm Code NFPA-72
Optional: Cover Tamper Switch. or(Jer Stk. No. 0090018
the Model VSR-SF is a vane type waterllow switch for use on wet
sprinkler systems that use 1',1 1/4', or 1 112' pipe size. 'The unit
may also be used as a sectional W3terllow detector on large
systems. .
The unit contains two single pole double throw snap action
switches and an adjustable. instantly recyding pneumatic retard.
the switches are actuated when a now of 10 gallons per minute or
more occurs downstream of the device. The flow condition must
exist lor a period of time necessal)' to overcome the selected retard
period.
INST At.LA TION: These devices may be mounted in horizontal or
vertical pipe. 00 horizontal pipe they should be installed on the top
side of the pipe where they will be accessible. The uoits should not
be installed within 6' of a valve. drain or fitting which changes the
direction of the waterllow. The unit has a 1" NPT bushing for
threading into a non~rrosive TEE. See Fig. 2 for proper TEE
size. type and installation.
Screw the device ioto the TEE fftting as shown io Fig. 2. Care must
be taken to propel1yorient the device for the c:fcrection of watenlow.
The vane must not rub the inside of the TEE or bind in any way.
The stem should move freely when operated by hand.
The device can also be used in copper or plastic pipe installations
with the proper adapters so that the specified TEE fitting may be
installed on the pipe run.
INSPECTION AND TESTING: Oled< the operation of the unit by
opening the inspector" test vatve at the end of the sprinkler line or
the drain and test connection. if an inspector"s test valve is not
provided.
II there are no provisions lor testing the operation of the flow
. detection device 00 the system. application of the VSR-SF is not
recommended or advisable
The frequency 01 the inspection and lesting and its associated
protective monitoring system should be in accordance with the
applicable NFPA Codes and Standards and/or authority having
;uriS<ftCtioo (manufacturer recommends quartel1y or more
Il'equeotly).
PRINTED IN USA
PAGE 1 OF 2
MKT. <<8800003. REV J
MFG. <<5400802 - 819S
(jI'ORT"",
{~~~
r-Bii
L --
""""""
CITY OF PORT ANGELES
PUBLIC WORKS - UTILITIES DIVISION
321 EAST 5TH STREET, PORT ANGELES, WA 98362
os -q~
Application Number
Application pin number
Property Address . . .
ASSESSOR PARCEL NUMBER:
Tenant nbr, name
Application type description
Subdivision Name
property Use
Property Zoning . . .
Application valuation
05-00000964 Date
658940
1401 AURORA CT
T6-30-00-1-0-7800-0007-
LOT 7
RES NEW SFR
ll/30/05
14D/~t6
RS9 RESDNTL SINGLE FAMILY
189240
Owner
Contractor
()~L~Dw
OLYMPIC LAND DEVELOPMENT INC.
259403 HWY 101
SEQUIM WA 98382
(360) 457-7222
Other struct info
WANT ACTION CONSTRUCTION
P. O. BOX 1425
SEQUIM
(360) 681-3992
TOTAL % LOT COVERAGE
NUMBER OF STORIES
LOT SIZE
TOTAL LOT COVERAGE
NUMBER OF UNITS
INC.
WA 98382
27.00
1. 00
9008.00
2398.00
1. 00
Permit PUBLIC WORKS RES WATER SERV
Additional desc 3/4" DROP IN WATER METER
Permit pin number 63024
Permit Fee 195.00 Plan Check Fee .00
Issue Date ll/30/05 Valuation 189240
Expiration Date 5/29/06
_...__._:~~~___~~~~=~~~~~~_~;::__~~_~~~_~~~_:~~:________________.~t~;~:~
Permit . . . . .
Additional desc .
Permit pin number
Permit Fee
Issue Date
Expiration Date
RIGHT OF WAY
63008
50.00
11/30/05
5/29/06
Plan Check Fee
Valuation
.00
189240
+; i1cJ0
1A"'-O~
IF"V'
Qty Unit Charge Per ~
1.00 50.0000 ECH RIGHT OF WAY PERMIT ~
-----;~~~~--~-~-~-~-~-~--;~~;~;-;;~;;-~~~;-~;---------------- -------- -
Additional desc .
Permit pin number
Permit Fee
Issue Date
Expiration Date
63016
110.00
ll/30/05
5/29/06
Plan Check Fee
valuation
.00
189240
Qty
1. 00
Unit Charge Per
110.0000 EA SAN SEWER HOOKUP
Exte
110.00
Special Notes and Comments
Building address sign shall not be less than 6" & not more
than 12" in height. Numbers colors must contrast with wall
color they are mounted on. (Ord. 14.36. 050-E)
When roof gutters are installed, drains will located in dry
wells or piped to approved storm drain location. No
Separate Permits are required for electrical work, SEPA, Shoreline, ESA, utilities, private and public improvements. This permit becomes
null and void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned
for a period of 180 days after the work as commenced, or if required inspections have not been requested within 180 days from the last
inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of
laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not
presume to give authority to violate or cancel the provisions of any state or local law reguiating construction or the performance of
construction.
Signature of Contractor or Authorized Agent
Date
Signature of Owner (if owner is builder)
Date
T:\Policies\J J02.J5R [1/05]
~,ORT .......
lO~,\~
h!ii
L~
~
"'<~
CITY OF PORT ANGELES
PUBLIC WORKS - UTILITIES DIVISION
32 J EAST 5TH STREET, PORT ANGELES, W A 98362
Application Number . . . . . 05-00000964
Application pin number 658940
Page 2
Date 11/30/05
Special Notes and Comments
pressurized or pumping to curbs are allowed. An inspection
by Building Department is required prior to backfill.
Address numbers shall be plainly visible from the street.
Address numbers shall be a minimum of six inches high and be
of contrasting color from the background.
All homes in new subdivisions that are outside of the Fire
Department four-minute response area shall be equipped with
residential fire sprinkler systems that .comply with the
International Fire Code (IFC) and National Fire Protection
Association (NFPA).
10/25/2005 01:15 PM SROBERDS -- The proposal will result
in a new sfr w/attached garage for total lot coverage of
27%. NO occupancy will be issued until all road and
utility improvements have been installed and approved.
Electrical load calculations and elctrical permits are
required.
Electrical connection fee required of $222.00.
10/19/2005 11:47 AM GMCLAIN ----------------------------
Ditches & 12" culverts will be installed to City Stanards.
See Public works Engineering for Standards.
Sanitary sewer connection inspection is required by
public Works prior to back fill of ditch. 24 hour advance
notice is required.
Construct driveway and Sidewalks to City Standards.
No concrete with exposed aggregate allowed in the City
road right of way. An inspection by Public Works
Engineering is required prior to prouring concrete.
Other Fees
SEWER SYSTEM DELV CHARG
STATE SURCHARGE
PW WATER SYSTEM USE FEE
745.00
1025.00.
Fee summary Charged Paid Credited Due
----------~------ ---------- ---------- ---------- ----------
Permit Fee Total 355.00 355.00 .00 .00
Plan Check Total .00 .00 .00 .00
Other Fee Total 1774.50 1774.50 .00 .00
Grand Total 2129.50 2129.50 .00 .00
Separate Permits are required for electrical work, SEPA, Shoreline, ESA, utilities, private and public improvements. This permit becomes
null and void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned
for a period of 180 days after the work as commenced, or if required inspections have not been requested within 180 days from the last
inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of
laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not
presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construction.
Signature of Contractor or Authorized Agent
Date
Signature of Owner (if owner is builder)
Date
T:\Policies\II02.15R [1105]
CITY OF PORT ANGELES
DEPARTMENT OF PUBLIC WORKS
. . . . . . . . . . . INSPECTION REPORT. . . . . . . . . . .
REQUEST: J )
Date I .?{ D J.<1 Time
Location of Work to be inspected
Name of person requesting inspection
Address of person requesting inspection
Type of Inspection (circle appropriate one):
~~ Foundation Framing Chimney
1r
xJ:~L!;~ALt1fiA
Phone No. 'i?tJ1 -o4C;C;
Permit No. O"5-q~
Plumbing Final Sewer Excav. Other
Received by
(phone, person)
INSPECTION NOTES: ) )
Inspected: Date I~. Vv Time
Remarks: 'ill ?vc. ,c<,>,^",e.c-i,'",,,, to ~";5t/''''j
L/ I rl Q..<e p
By ~/ftI.
(, 'I N~ 1~t-vQ L.a." Pi'of'eAy I.'",-e.....
RESTORATION REQUIRED. . . . .. YES NO
j L t
tV
(CjR 5{~"Q.T .
M(tt
, ,
~ct.,'^
1
'-II; r
t r
6.... PfL
IJ( 27' ~/6 '1.f~~
.' /
/... /. 1.v /' .::+:- N 5"'-
u 6 ~~'"f /1::' '(I/ ~7 'fl""
I! J i'rc:.
e xi'~.. ,',-
e -' b""'P c-
.::; 14~
~ Pll A c.-(
SURFACE RESTORATION:
SURFACE TYPE: 0 Unimproved OGravel o Asphalt OPCC
o Other
o Repaired by City
o Repaired by Permittee
o No Damage Found
Work Order #
o COMPLETE
D INCOMPLETE
lr.:nntintJA.on.rAverSQ,side.if nec:ess:nv)
"......""........"........................................
CITY OF PORT ANGELES
DEPARTMENT OF PUBLIC WORKS
. . . . INSPECTION REPORT. . . . . . . .
REQUEST:
Date II -"5 - D ~
Time
Received by
RV
(phone, person)
Location of Work to be inspected I '-t D I A bLr t9 ra.. c.. +-
Name of person requesting inspection <;'l-L'i.()""VI,Q 'PI' tr> T
Address of person requesting inspection Phone No. L./ f, (') - 1112
Type of Inspection (circle appropriate one): Permit No. i:)<;- - q b i
Sewer Foundation Framing Chimney Plumbing(Fi~ Sewer Excav, Other
INSPECTION NOTES:
Inspected: Date 1/- b - D (0 Time
Remarks: <;;euJQr- I-~t- Ob
I/-b-b
-+ (> .siov vu.. bro...' ""
By
72; V
11-4:, -0(".
RESTORATION REQUIRED. . . . .. YES
NO ><-
SURFACE RESTORATION:
SURFACE TYPE: 0 Unimproved OGravel o Asphalt OPCC
o Other
o Repaired by City
o Repaired by Permittee
o No Damage Found
Work Order #
o COMPLETE
o INCOMPLETE
'~
w
CITY OF PORT ANGELES
PUBLIC WORKS - ELECTRICAL DIVISION
121 EAST 5TH STREET. PORT ANGELES. WA 98362
Application Number
Application pin number
Property Address
ASSESSOR PARCEL NUMBER
Tenant nbr, name
Appl~cat~on type description
Subdivision Name
Property Use
Property Zoning
Application valuation
05-00000964 Date
658940
1401 AURORA CT
06-30-01-7-5-0070-0000-
LOT 7
RES NEW SFR
2/07/06
RS9 RESDNTL SINGLE FAMILY
189240
Owner
Contractor
OLYMPIC LAND DEVELOPMENT INC
259403 HWY 101
SEQUIM WA 98382
(360) 457-7222
Other struct info
WANT ACTION CONSTRUCTION
P O. BOX 1425
SEQUIM
(360) 681-3992
TOTAL % LOT COVERAGE
NUMBER OF STORIES
LOT SIZE
TOTAL LOT COVERAGE
NUMBER OF UNITS
INC.
WA 98382
27 00
1 00
9008 00
2398 00
1. 00
Permit
Add~tional desc
Perm~t pin number
Sub Contractor
Permit Fee
Issue Date
Expiration Date
ELECTRICAL NEW RESIDENTIAL
JARMUTH/ 2228 SQ FT SFR
70532
JARMUTH ELECTRIC
119 80
2/07/06
8/06/06
Plan Check Fee
Valuation
00
o
~
~
L
I
~
~
~
~
Qty
1 00
2 00
Unit Charge Per
73 0000 ECH
23 4000 5C
EL-R-SQFT FIRST 1300
EL-R-SQFT ADDITIONAL 500
Extension
73.00
46 80
Special Notes and Comments
Bu~ld~ng address sign shall not be less than 6" & not more
than 12" ~n he~ght Numbers colors must contrast w~th wall
color they are mounted on (Ord. 14 36 OsO-E)
When roof gutters are installed, drains will located in dry
wells or piped to approved storm drain location. No
pressurized or pumping to curbs are allowed An inspect~on
by Build~ng Department is required prior to backfill.
Address numbers shall be plainly visible from the street.
Address numbers shall be a minimum of six inches high and be
of contrasting color from the background
All homes ~n new subdivis~ons that are outside of the Fire
Department four-minute response area shall be equipped with
residential fire sprinkler systems that comply w~th the
International Fire Code (IFC) and Nat~onal F~re Protect~on
Assoc~at~on (NFPA)
10/25/2005 01.15 PM SROBERDS -- The proposal will result
~n a new sfr w/attached garage for total lot coverage of
27% NO occupancy will be issued until all road and
util~ty improv~ments have been installed and approved
Electr~cal load calculations and elctrical permits are
required
Electrical connection fee required of $222 00
10/19/2005 11 47 AM GMCLAIN ----------------------------
R
COMMENTS/ ACTION NEEDED
g
~
CITY OF PORT ANGELES
PUBLIC WORKS - ELECTRICAL DIVISION
nl EAST 5TH STREET. PORT ANGELES. WA 98362
.
Application Number
Appllcation pin number
05-00000964
658940
Page
Date
2
2/07/06
Speclal Notes and Comments
Ditches & 12" culverts will be installed to City Stanards
See Public Works Engineering for Standards
Sanltary sewer connection inspection is required by
Publlc Works prior to back fill of ditch 24 hour advance
notlce lS requlred
Construct driveway and Sidewalks to City Standards
No concrete with exposed aggregate allowed in the City
road right of way An inspection by Public Works
Engineering is required prior to prouring concrete.
Other Fees
SEWER SYSTEM DELV CHARGE
STATE SURCHARGE
PW WATER SYSTEM USE FEE
745.00
4.50
1025.00
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 119 80 119 80 00 00
Plan Check Total .00 00 00 00
Other Fee Total 1774 50 1774.50 00 00
Grand Total 1894.30 1894 30 .00 00
COMMENTSI ACTION NEEDED
\
ELECTRICAL PERMIT INSPECTION RECORD
CALL 417-4735 FOR ELECTRICAL INSPECTIONS. PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLA WFUL TO COVER,
INSULA TE OR CONCEAL ANY WORK BEFORE IT IS INSPECTED AND ACCEPTED.
KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE
INSPECTION TYPE DATE ACCEPTED COMMENTS
YES NO
DITCH
~()T IlyH_lN I CUV.hK
~.hK V lCh
'T>. ,-rT~ fo - q - () "I ~A-i:J"'Jl
GENERAL COMMENTS:
PW.ll02 U 14196]
02/02/2006 08:34
360-681-7272
JARMUTH ELECTRIC
PAGE 04
-
(;t'11/)
g{lectrteR' CookRdor
C ADD.U.. Permlt a Alarlll
. ELECTRICAL WORKPERMIT APPUCA110N I
o Oo;::lval 0 Commercial ~Ideatlal 0 ReBldeallal Malot. 0 Sip. 0 TberolD...t IJ ll:locom.
Job ..Ired by
EledrleR' CaDtnetor 0 Owoer
In.lallation deleriptioa \
~ S~ ,r,.,J-- ?t!'.$/"I ~e -c.
EI.~~:;tcl.r .ame r.-J.r. . -r LiceDac numbar
IA .u- j;J~ 1t:...JJI c::-
Purdlaoer', mailing addro.. ~ 0 f
3~'f W vu..~ 11-1 ...7
City la'e ZIP
5~ fJ'h WA- o/r?'~ 2.-
Telephone ber FAX n\lmber
-:2 Z.
. ])'t} t' (t'fmvn.1-
C~
n\:>o
S"l.g
z.."L'Z.8 r.:p ~r
o Cash 0 Check #
I her<by cenify that I om the owner of the above lllllIled property or n Iicenoed _./ d' Card
I.lt'Cre It Visa MlI8tercard Discover
electrical contractor (or the finn's authorized fl8ent) and lIIP making the electrical
iDslal1ation or alteration in compliance with the elecmcallaw. Cbapter 19.28 RCW. Card # . ~..Ll- Rk _' _ _ _ _' _ _ __
x
ExpiIation Date
of card
o
WAlLS
In.ulation Only
CElUNG
Inl"larion Only
THERMOSTAT
SERVICE
2- /, '" / IX, 4cCJ
~ Appmwd8y
I' U!.IJI!A
D_ ApJIIond By
#~ -.".....,
. :z.. Cover ~1:;Q
OtiC AftPfO"t Y
D.uo "","WIll By
z../z-:S/D"cover ,hn
I OAt ~J'y
IJO'(]I
;) '&>'b~ kn,
D'III ~
Dab ~By
EllIctrlCRI Load AddltlonR and or aubtl'llctlonl
o NO LOAD CHANGES
IJ Ilooe_rd ICN
lin'urnaco ~ KW
lIfIaot Pump 2- Too _ LAR
IJ Fan-Wan _ICN
o OVemoad Servloa
IJ Tamp Servico
I!'Undarground Servloa
Service Infonnatlon
VoIlaga 1~/'IfD
PhRM Iln 0'3
S.rvtca Slza: ~ J
F_r SI..: ~'21
Inapcction
Date
Area, lIuilding or Equipmenllnspectecl
Action Taken
Electrical
Inspector
-z. 'I 00
-.
ee.-- roD
41 9- z.-"'L-
0.1-.
L
~p
. .,
ElECTR~CAlINSPECTION
WIRING REPORT
417-4735
PERMIT #
c..
APPROVED NOT APPROVED
o .................... DITCH. . . . . . . . . . . . . . . . . . . . 0
D. . . . . . . . . . . . . . . . ROUGH IN/COVER. . . . . . . . . . . . . . . 0
D. .-: . . . . . . . . . . . . . . . . . SERVICE. . . . . . . . . . . . . . . . . . . 0
D.................... . FINAL ................... X
CORRECTIONS NEEDED: @ ;::/ LL-~ ~~
eJ.fL A-'~ fI'...." ~ ,~"P.Ar..$
,
~,,~s.a Ui/I/<J~ ~_ Lrs.
@
,~~./.
/;'v'f.JC. J...A~AF<;'
"""/.$ ~ NY c..
(jJ h7/SS1#c. c.~tA- ~A-5~-- 5/fr7/-
~# rf71-ct-. <:;r- ~A-.N
~~ .I"J-v ,,#L.L ~~.." ,<;
~ ~"~ ~: n~=
@ EX?7Uf ;t?OK- B: /-U .w//f~
& /tf!!,4NS~~ (A1er /lO-~
NOTIFY INSPECTOR WHEN CORRECTIONS
t1f;) ARE COMPLETED WITHIN 15 DAYS
l.g/ na "fL&>>PO~W.(~~MO~cr- z,Jodd?b
OLYMPIC PRINTERS, INC. (360) 452-1381
ELECTRICAL INSPECTION' "'
WIRING REPORT
417-4735
'1
APPROVED NOT APPROVED
o .' 11 '.: . ~ . . . . . . . . . . . DITCH. . . . . . . . . . . . . . . . . . . . 0
)t. . f1f,N(J;. lb. . . . . ROUGH IN/COVER. . . . . . . . . . . . . . . 0
C~'. '.~I~~'. '. '. ...... '. S:~V~~E : : : : : : : : : : : : : : : : : : ~
~~ ~~~?
CORRECTIONS NEEDED: ~./ AA~1 t"'.L)t/~ +
/A/:s77/-u- ~/LA~.M' r'~ or- ~CJ
.
/ft?n J - L.l;O
:~ -U~ :~s~
<'
~
t%-L-
vJ#bkl
6h"",oUd _
"
AI IF -/f/J/.iJ (;J f~ c;.;E.
('..{7u/J UN {;,
I
fJe:CMT?4L'
NOTIFY INSPECTOR WHEN CORRECTIONS
ARE COMPLETED WITHIN 15 DAYS
- DO NOT REMOVE -
OLYMPIC PRINTERS, INC. (360) 452-1381
11/09/2005
12:43
350-581-7272
JARMUTH ELECTRIC
PAGE: _.01
:,~ ....'.~:.,'>""'.....~~j,.f, M':;""..';l:O; A..~
I . . :~-' ,( -
I' .j.
ELECTlUCAL WORkPDMrr AP'PtICATlON
r ;!
'.
,
. ......;.~:~" 4' 'I'l!
'. ...'" ~,~, ., .. t. ".
,.....',"\r".,"!l'."",,.. ,:~,~'.I~ .1""\'- i~."
~C"hWdor OOwaer.
CJ 0..11...... CJ Alarm CJ CanJv.1 lJ Co_erdll ~"U'I' CJ b1dollllal~. O!l.... ill TIle
.;
r- _..h____ - - ..
" --_.--._.
--
i;.
caw...
j." wlMl by
o Electrk:el CHti'llCtor CJ Ow."
h1ota1l._ deocrlptlol, .
~~ :5~~~rr~
I!"~"nlr_ '''''i::b Lic....~
tartn 1.1 F/~c..ft..~('_ I'IC-
_'Imallla&_
--R~ l3D1 ./4 ~,S-
CllJ S S.... ZIP
~ e~(A.ivY\. (,.VA- "~9 >
1'o1lp_. be. FAX_
/..
l.
x
O~ OCbeckIl
II'Credit Card Visa . MulI:rcard DheO\'el'
Cardll. -LIbJ$:L-r:;_,____"____
ExpirlltlOll Dele
or card
...,..rion ....
S
I boreby certify that I BIll tho owner of III. above 11IIII0<1 properlY or a Iioonolid
<<IoclricoI 00Il_ (01' tile h'. IllIhorized _I) ODd BIll maIdDa tIIo .loeIricaI
lDIlallatiou or aIleratio. in eomplimc:e wllll tIIo .1ettrlea1Iaw, Cboplor 19.28 RCW.
WALLS
luulaliOll. Only
cmJNG
lnaulatloo Only
'I1IERMOSIAT
SDVD
Cover
Cover
mal
~ ~~
.~
D.. ~ By
~ AfIPI'I"'IdB)"
D.. """"'" By
....
........'"
DIl'
~BJ
...
-.
...
.....,._1 L...... A.ddHlona .nd IIr .UbtrllctloM
lJ NO LOAD CHANGES
a"_rd KW
a Furnue =KW
a_Pump _ Ton_LAR
a F.n-Well _ KW
L.. L61nfo.._11wl
CJ g.6theod s.......
trTemp S......
o UnclII'gI'Ound _
Vollege
P_0103
SeiWle SIn:_
FIIdo< SIze:
Jnlpec:tton
Date
ARo, Building or Equipment Inapecled
f
6J4,1L---
~
If - -oS-
d'~'~
~
a~
CITY OF PORT ANGELES
PUBLIC WORKS . ELECTRICAL DIVISION
m EAST STH STREET. PORT ANGELES. WA983(,2
Application Number
Application pin number
Property Address
ASSESSOR PARCEL NUMBER:
Application type description
Subdivision Name
Property Use
Property Zoning
Application valuation
05-00001105 Date 11/14/05
237960
14 0 1 AURORA CT
T6-30-0Q-I-O-780Q-0007-
ELECTRICAL ONLY
RS9 RESDNTL SINGLE FAMILY
o
Owner
Contractor
OLYMPIC LAND DEVELOPMENT INC.
259403 HWY 101
SEQUIM WA 98382
(360) 457-7222
JARMUTH ELECTRIC
PO BOX 635 SEQUIM
SEQUIM
(360) 683-4104
WA 98382
Permit
Additional desc
Permit pin number
Sub Contractor
Permit Fee
Issue Date
Expiration Date
ELECTRICAL TEMPORARY SERVICE
JARMUTH/ 60A TEMP SVC.
65037
JARMUTH ELECTRIC
42.20
11/14/05
5/13/06
plan Check Fee
Valuation
.00
o
Qty
1. 00
Unit Charge Per
42.2000 ECH EL-TEMP SRV - 0-60 SRV FDR
Extension
42.20
Fee summary Charged Paid Credited Due
------------ ---------- ---~~---- ---------- ----------
Permit Fee Total 42 .20 42 .20 .00 .00
Plan Check Total .00 .00 .00 .00
Grand Total 42 .20 42. 20 .00 .00
COMMENTSI ACTION NEEDED
Application Number . . . . . 23-00000998 Date 9/19/23
Application pin number . . . 754200
Property Address . . . . . . 1401 AURORA CT
ASSESSOR PARCEL NUMBER: 06-30-01-7-5-0070-0000-
Application type description ELECTRICAL ONLY
Subdivision Name . . . . . .
Property Use . . . . . . . .
Property Zoning . . . . . . . RS9 RESDNTL SINGLE FAMILY
Application valuation . . . . 0
----------------------------------------------------------------------------
Application desc
T-stat
----------------------------------------------------------------------------
Owner Contractor
------------------------ ------------------------
RICHARD L AND DAWN I FRENCH DAVE'S HTG & COOLING SRVC INC
1401 N AURORA CT PO BOX 413
PORT ANGELES WA 98363 PORT ANGELES WA 98362
(360) 452-0939
----------------------------------------------------------------------------
Permit . . . . . . ELECTRICAL ALTER RESIDENTIAL
Additional desc . .
Permit Fee . . . . 56.00 Plan Check Fee . . .00
Issue Date . . . . 9/19/23 Valuation . . . . 0
Expiration Date . . 3/17/24
Qty Unit Charge Per Extension
1.00 56.0000 ECH EL-LVT-THERMOSTAT 56.00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 56.00 56.00 .00 .00
Plan Check Total .00 .00 .00 .00
Grand Total 56.00 56.00 .00 .00
1 - 2 SINGLE-FAMILY
ELECIBICAL PERMIT AeP_LJCAIIO~.
Public \Yorks and lJLilities Department
321 E. 5th Street. Port Angeles, WA 98362
360 .417.4715 I www.cityofpa.us / clectricalperruitsrc.cityofpa.us
1401 Aurora Ct
Project Address:--------------------------------------
. , • Low voltage thermostat wire for thermostat as part of a ducted heat pump system
Project Description:-------------------------------------
0 Single-Family Residential D Duplex/ ARU Building Square footage: ...:.1.c..7=-28~-------
Name: Richard French
Mailing Address: 1401 Aurora Ct, Port Angeles, WA 98363
Email: th_e frenches@hotmail.com
Phone: 20099291247
Name: Dave's Heating & Cooling Services, Inc.
Mailing Address: PO Box 413, Port Angeles, WA 98362
Email: davesheatinq@.wavecable.com
License: DAVESHC9912C
Expiration Date: _0_5/_2_0_2_;._5 _
Phone: 3604520939
11!.m
Serv ice/Feeder 200 Am p.
Serv ice/Feeder 201-4 00 Am p.
Serv ice/Feeder 401-600 A m p.
Serv ice/Feeder 601-1000 Am p.
Serv ice/Feeder over 1000 A m p.
Branch Circuit W/ Serv ice Feeder
Branch Circuit W/O Serv ice Feeder
Each Additional Bra nch Circuit
Branch Circuits 1-4
Tem p. Serv ice/Feeder 200 A m p.
Tem p. Serv ice/Feeder 201-400 Am p.
Tem p. Serv ice/Feeder 401-600 Am p.
Tem p. Serv ice/Feeder 601-1000 A m p.
Portal to Port al Hourly
Signal CircuiULim ited Energy - 1 &2 DU.
M anufactured Hom e Connection
Renew able Elec. Energy: 5K VA System or less
Therm ostat (Note: $5 for each additional)
First 1'300 Square Feet
Each Addition al 500 square feef'
Each Outbuilding / Detached Garage
Each Swimming Poof/ Hot Tu b
Unit Charg l!i 2ua o1illl
$120.00
$146.00
$205.00
$262.00
$373.00
$5.00
$63.00
$5.00
$75.00
$93.00
$110.00
$14 9.00
$168.00
$96.00
$64.00
$120.00
$10 2.00
$56.00 1
$120.00
$4 0.00
$74.00
$110.00
TOTAL
To.1il (Q u a n tity x U n it C h a rg e )
$ _
$ _
$ _
$ _
$ _
$ _
$ _
$ _
$ _
$ _
$ _
$ _
$ _
$ _
$ _
$ _
$ _
$ 56.00
$ -;
$ .:___
$ _
$ ------------ $ _
Ow ner as defined by RCW.19 .28.261: (1) Ow ner will occupy the struct ure fo r tw o years after this electrical perm it is finalized. (2) Ow ner is
required to hire an electrical contractor if above said property is for sale, rent or lease. Permit expires after six months of last inspection.
A fter reading the above statem ent, I hereby certify that I am the ow er f the ve nam ed property or a licensed electrical contractor. I
am m aking the electrical installation or alteration in compliance wi h he e ctri al la ., CW. Chapter 19.28, WAC. Chapter 296-
468, The City of Port Angeles Municipal Code, and Utility Specific · s d A egarding Electrical Permit Applications.
9/15/23 Laci Williams
Date Print Name Electrical Contractor/ Administrator)
[Electrical Permit Applications may be submitted to City Hall or electricalpermits@cityofpa.us]
ELECTRICAL INSPECTION WIRING REPORT
APPROVED NOT APPROVED
DITCH
ROUGH IN/COVER
SERVICE
FINAL
COMMENTS
NOTIFY INSPECTOR at (360) 808-2613
WHEN CORRECTIONS ARE COMPLETED
WITHIN 15 DAYS
DATE PERMIT # INSPECTOR
10/4/2023 23-998 TAP
OWNER
CONTRACTOR
Dave’s Heating
PROJECT ADDRESS
1401 Aurora Ct