HomeMy WebLinkAbout432 E Ahlvers Rd - BuildingNovember 29, 2010
—Mr. _Jan_Didrickson
430 E. Ahlvers Road
Port Angeles, WA 98362
Re Building Permit 07 -46
430 E Ahlvers Road
Dear Mr Didrickson
With reference to the sewer line that was discovered running under your residence (430 E Ahlvers
Road), as you know the old line serves the residence at 432 E Ahlvers Road Although the City
requested that the newly found line be capped, this action will result in a cessation of sewer service
to 432 E. Ahlvers Road Without cooperation from that property owner we realize you cannot
disconnect the service, and so it remains.
This letter is to acknowledge that, while you were willing to cap the line, you were not able to do so
without cooperation of the receiving property owner at 432..E Ahlvers Road Therefore, this letter
is meant to memorialize the previous :conversations and actions, and to give notice that, should the
line fail, it is.a.private line and not the responsibility of the City In the event of failure, the property
owner at 432 E Ahlvers Road will be required to make a new connection into the 8' line west of
the property to which your new sewer is now connected If the line fails, once the new connection
is made by the neighboring property owner you will need to cap the line at that time
If you have any questions with this information, please don't hesitate to contact this Department.
Once again, this letter is only to notify you and the neighbor of the situation s� we can close the file
and final your long overdue building, permit.
W A S H I N G T O N U S A
Community Economic Development Department
Sue Roberds
Planning Manager
Cc: Jennifer Zavodney 432 E. Ahlvers Road
Phone 360 -417 -4750 Fax: 360 417 4711
Website: www cityofpa.us Email smartgrowth@cityofpa.us
321 East Fifth Street P 0 Box 1150 Port Angeles WA 98362 -0217
CITY OF PORT ANGELES
PUBLIC WORKS ELECTRICAL DIVISION
321 EAST 5TH STREET. PORT ANGELES. WA 98362
Application Number 07- 00000650 Date 6/07/07
Application pin number 508350
Property Address 432 E AHLVERS RD
ASSESSOR PARCEL NUMBER: 06-30-15-3-1- 9080 -0000-
Application type description ELECTRICAL ONLY
Subdivision Name
Property Use
Property Zoning RS9 RESDNTL SINGLE FAMILY
Application valuation 0
Owner Contractor
BALLARD BARRY SUZETTE
432 E AHLVERS RD
PORT ANGELES WA 983623708
OWNER
Permit ELECTRICAL NEW RESIDENTIAL
Additional desc OWNER/ OH TO UG
Permit pin number 104109
Permit Fee 75.00 Plan Check Fee .00
Issue Date 6/07/07 Valuation 0
Expiration Date 12/04/07
Qty Unit Charge Per Extension
1.00 75.0000 ECH EL -RM -0 -200 1ST SRV FEEDER 75.00
Fee summary Charged Paid Credited Due
Permit Fee Total 75.00 75.00 .00 .00
Plan Check Total .00 .00 .00 .00
Grand Total 75.00 75.00 .00 .00
COMMENTS /ACTION NEEDED
ELECTRICAL PERMIT INSPECTION RECORD
CALL 417 -4735 FOR ELECTRICAL INSPECTIONS. PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAWFUL TO COYER,
INSULATE OR CONCEAL ANY WORK BEFORE IT IS INSPECTED AND ACCEPTED.
FINAL
GENERAL COMMENTS:
KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE
INSPECTION TYPE DATE ACCEPTED
YES 1 NO
DITCH I I
ROUGH I
S.bRV ICE I I
COMMENTS
PW- 1102.I5 1v96)
ILDING PERMIT
OWNER/APPLICANT
BARRY BALLARD
432 AHLVERS
Port Angeles, WA 98362
360/452 -1602
T:
CONTRACTOR ARCHITECT
PENINSULA HEAT N/A
502 W. 8th Street
Port Angeles, WA 98363 98360 -0000
360/457 -2775 360/000 -0000
PROJECT INFO
Project Value: $2,101.00 SFD Units: 0 Commercial: 0
Project Type: HEAT PUMP ADD SFD SQ FT: 0 Industrial: 0
Occupancy Type: RESIDENTIAL Garage: 0
Occupancy Group: MFD Units: 0
Construction Type: MFD SQ FT: 0
Zoning Use: RS9
PROJECT NOTES
INSTALL HEAT PUMP AND LOW VOLTAGE THERMOSTAT
RECEIPT#9102
CITY OF PORT ANGELES
DEPARTMENT OF COMMUNITY DEVELOPMENT BUILDING DIVISION
321 EAST 5TH STREET, PORT ANGELES, WA 98362
ISSI 1Ffl 5/92/200 PERMIT NO: 13444
S:
PROPERTY LOCATION
432 AHLVERS RD E
Lot: 21 22
Block: Long Legal
Subdivision: TPA
Parcel No: 063015319080000
FEES ASSESSMENT
Building Permit: $0.00 Misc Fee 1: THERMOSTAT $34.40
Plan Check: $0.00 Misc Fee 2: $0.00
State Surcharge: $0.00 Misc Fee 3: $0.00
House Moving: $0.00
Manufactured Home: $0.00
Sign: $0.00 TOTAL FEE: $68.55
Plumbing: $0.00 AMOUNT PAID: $68.55
Mechanical: $34.15 BALANCE DUE: $0.00
Radon: $0.00
Separate Permits are required for electrical work, SEPA, Shoreline, ESA, utilities, private and public improvements. This permit becomes
null and void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned
for a period of 180 days after the work as commenced, or if required inspections have not been requested within 180 days from the last
inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of
laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not
presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construction.
(j A/ F// E
Signature of Contractor or Authorized Agent Date Signature of Owner (if owner is builder) Date
T: \PLANNING \FORMS \1102.15 [4/2002]
BUILDING PERMIT INSPECTION RECORD
CALL 417 -4815 FOR BUILDING INSPECTIONS. PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAWFUL TO COVER,
INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT IN A CONSPICUOUS LOCATION.
INSPECTION TYPE
KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE
DATE ACCEPTED
FOUNDATION:
FOOTINGS
WALLS
FOUNDATION DRAINAGE
ELECTRICAL (LIGHT DEPT) SEPARATE PERMIT:
ROUGH -IN
PLUMBING
UNDERFLOOR /SLAB
ROUGH -IN
WATER LINE
GAS LINE
BACK FLOW WATER
AIR SEAL
WALLS
CEILING
FRAMING
JOISTS GIRDERS
SHEAR WALL
WALLS ROOF CEILING
DRYWALL
T -BAR
INSULATION
SLAB
WALL FLOOR CEILING
MECHANICAL
HEAT PUMP
WOOD STOVE PELLET CHIMNEY
HOOD /DUCTS
PW UTILITIES SITE WORK (Engineering Division) SEPARATE PERMIT #'s:
WATERLINE METER
SEWER CONNECTION
SANITARY
STORM
PLANNING DEPT SEPARATE PERMIT #'s
PARKING /LIGHTING
LANDSCAPING
YES NO
SEPA:
ESA:
SHORELINE:
COMMENTS
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE
RESIDENTIAL DATE I YES NO COMMERCIAL DATE ACCEPTED I
YES 1 NO
ELECTRICAL LIGHT DEPT. 417 -4735 I I
LIGHT ELECTRICAL
CONSTRUCTION R.W. PW/ CONSTRUCTION R. W.
ENGINEERING 417 -4807 PW ENGINEERING
FIRE 417 -4653 I FIRE DEPT.
PLANNING DEPT. 417 -4750 I I 7/ I PLANNING DEPT.
BUILDING 417 -4815 17 I /(3.61- n 1 BUILDING 1
77
T:\PLANNING \FORMS \1102.15 [4/2002]
LI Irina
BUILDING PERMIT PREAPPLICATION
The Budding Permit Preapplicatlon must be f frd out Corrtpleteiy.
Please type or print in ink. If you have any questions, please call 417 -4815
Applicant and/or Agent: e&iittio le i' ndvrson)
Owner &$Y7 ,641//4rd/
Address: flee
Architect/Elmer:
Contractor I'b,7.tn4u/LIYCGC' ,.TtC— Licens
Address:50A W ,P± City:
PROJECT ADDRESS: 4 iL E teer
LEGAL DESCRIPTION: Lot: 2 2 2 Block:
QG,3A
TYPJ -OF WORK:
esideitiai New Constr. Reroof Woodstgve
Multi- family Addition Move Garage
Commercial Remodel Demolition Deck
Repair Sign
BRIEF DESCRIPTION OF THE PROJECT: /7e
J
COMMERCIALIRESIDENTIAL: Occupancy Group:
No. of Stories: Lot Size: Lot Coverage:
Existing Lot Coverage: /sq. R Proposed Lot Coverage:
PLANNING USE ONLY:
Permits Required:
Max Height: Setbacks:
Site Plan and Use Approved by:
ESA/Wetland(s): Yes No SEPA Checklist required/ Yes o No
pu:CADATAt W TKEEPERS\BIDAPP. FRM
City: �D ft rl9Pl�s
SubdivisionA
SIZE/VALUATION:
SF. S /SF. F
SF. QS /SF. =S
SK /SF.
y q VrATIQN
gear u in
Applicant:
Occupant Load:
/sq. ft. TOTAL LOT COVERAGE:
Notes:
Zoning:
Date:
Other:
FOR OFFICIAL USE ONLY:
Data R-^•
Pamir a: 3
?m-Ap Complete?
Date Approved
Phone: 4 /57-2 77.5
Phone: 4/5.2 —1 40_7-
Zip:43b.—
Phone:
Phone:4 `7 2ZC
Zip: .9'731i
ZONING
51 79 tz\
Construction Type:
APPROVALS: PLAN
BLDG
DPW
FIRE
OTHER
/sq.ft
PREAPPLICATION SUBMITTAL.: Your application and site plan mast befdle.d out completely to be accepted for review. The Building
Division can provide you with more detailed information on the application and plan submittal requirements.
BUILDING PERMIT APPLICATION SUBMITTAL: Your completed application, site plan (for additions) and building construction
plans are to be submitted to the Building Division. Any addition larger than 500 sq. ft. will need a Preappllcation Review.
VALUATION 01? CONSTRUCTION: In all cases, a valuation amount must be entered by the applicant. This figure will be reviewed and
may be revised by the Building Div. to comply with current fee schedules. Contact the Permit Coordinator at 417 -4815 for assistance.
PLAN CHECK FEE: Your plan check fee is due at the time the building pernut application and construction plans are submitted. All other
perntit fees are due at the time of permit issuance.
EXPIRATION OF PLAN REVIEW: If no permit is issued within 180 days of the date of application, this application will expire by
limitatia s. The Building Official can extend the time for action by the applicant up to 180 days, on written request by the applicant (see Section
304(d) of the Uniform Building Code, current edition). No application can be extended more than once.
I herebycern/y that I haw read and examined this application and know the same to be true and correct, and 1 am authorized to apply/or
this permit. 1 understand it is not the City's legal responsibility to detennine7l+at permits are fired; it remains the applicant's
responsibility to determine what permits are required and to obtain such.
s rte: M
PW.1107.03(m.9/%I
:a/' ti .yyo7
-561 so j
ow 88°
rata
f ad enR �i tnitpa i ow joe:rmarjara-huschlopowzra mr_._rli:Ineriereinejeitarrust ,jesnairroglude°141114. a t f r 1 4sulegulugninalln. 1::::::r3:14€34Crif4.27:.
Wan
:ealS -0190,3 06%0 pfectiestil CI
145 WM
awn modati 7.
____-----------t4 't'S atild* ar:94.4 r: °aro 1,e,de VAI 5 'Pain. ,:..awevsnlalinattod
—97 AO
el 1140---"a5tna)laraard 10
Mat sauod sugrina au
few
s 1, SG
r
6106
vn
„lu
r
Job wired by
'Premises owner's name
-SE.-tree. 2 A-t/ o ht'i
Address of inspection
'13Z Avb-vc.is 1 XD
Electrical Contractor G(Owner
License number Date Expires
Electrical contractor name
Purchaser's mailing address
-AA—) 1111SwcJ 50∎) ?.o. Box 3i 13
City State ZIP
2o( P .)G t�A 9 G2
Telephone number FAX number
3c-o) 1 177- 73o7
Commercial
New
ELECTRICAL WORK PERMIT APPLICATION
'\,Installation description
Residential
a Altered /Addition
ac. Eyos7t..sc,
OgEQl -lAJa7 SERotC£ LJ/
City
I P- 4.Ec
Phone nn ber to schedule inspection:
t n k77 -43o7
Owner as elefined hr ROY 19.28,261:(1) Owner will occupy the structure for two
fears after this electrical permtit is finalised. (2) Owner is required to hire an electrical p J
contractor if above said property is for sale. rent or lease. Cash E Check 33' 1t 7
After reading the above statement, I hereby certify that I am the owner of the above
named property or a licensed electrical contractor. I am making the electrical instal- Credit Card Visa Mastercard Discover
lation or alteration in compliance with the electrical laws, N.E.C., RCW Chapter
19.28, WAC. Chapter 296 -46B, The City of Port Angeles Municipal Code, and Card
Utility Specifications.
/Signature of owner, electrical contractor or electrical administrator X Expiration Date
Inspection fee
a X Date: S'S /\of card KS 75 2s
Service Information
Electrical Load Additions and or subtractions
NO LOAD CHANGES
Baseboard KW Voltage
Furnace KW Overhead Service Phase 0 1 0 3
Heat Pump Ton LAR ❑/emp Service Service Size:
Fan -Wall KW 0 Underground Service Feeder Size:
SAME DAY INSPECTION, CALL BEFORE 7:00 AM 360 417 -4735
ROUGH -IN THERMOSTAT SERVICE
Inspection
Date
Doe Approved By y
FINAL
_4-a-1- 07
prCEI'JEO
JUIV 7 :,uut
Doe
Approved By
DITCH
Area, Building or Equipment Inspected
Approved By
Date
FEEDER
Approved By
Date .2 Dore Approved By
Action Taken
Electrical
Inspector
6-8-07 AN to /72_ v„,s.5`f71 /ol .VO flwijar REF f