PREPARED 7/18/14, 13:23:59 INSPECTION TICKET PAGE 3
CITY OF PORT ANGELES INSPECTOR: JAMES LIERLY DATE 7/18/14
------------------------------------------------------------------------------------------------
ADDRESS . : 111 OAKCREST AVE SUBDIV:
CONTRACTOR ROOF MANAGEMENT PHONE (360) 683-2272
OWNER PLOURDE GERTRUDE PHONE
PARCEL 06-30-16-5-3-0010-0000-
APPL NUMBER: 14-00000674 RE-ROOF
------------------------------------------------------------------------------------------------
PERMIT: BNOP 00 BUILDING PERMIT - NO PR FEE
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
-------------------------------------------------------------------
BL99 01 7/18/14 J L BLDG FINAL
July 18, 2014 10:27:19 AM pbarthol.
683-1832
-------------------------- -- -------- COMMENTS AND NOTES --------------------------------------
=^ CITY OF PORT ANGELES
DEPARTMENT OF COMMUNITY& ECONOMIC DEVELOPMENT- BUILDING DIVISION
321 EAST 5TH STREET, PORT ANGELES, WA 98362
Application Number . . . . . 14-00000674 Date 6/09/14
Application pin number . . . 073818
(� Property Address . . . . . . 111 OAKCREST AVE
VASSESSOR PARCEL NUMBER: 06-30-16-5-3-0010-0000- REPORT SALES TAX
Application type description RE-ROOF
Subdivision Name on your state excise tax form
Property Use . .. . . . . . . to the City of Port Angeles
Property Zoning RS7 RESDNTL SINGLE FAMILY
OApplication valuation _ 5971 (Location Code 0502)
Application desc
reroof SFR
----------------------------------------------------------------------------
Owner Contractor
PLOURDE GERTRUDE ROOF MANAGEMENT
111 OAKCREST AVE 325 E WASHINGTON ST. PMB 131
PORT ANGELES WA 983626928 SEQUIM WA 98382
(360) 683-2272
----------------------------------------------------------------------------
Permit . . . . . . BUILDING:PERMIT - NO PR FEE
Additional desc . . REROOF
Permit Fee . . . . 151.75 Plan Check Fee .00
Issue Date . . . . 6/09/14 Valuation . . . . 5971
Expiration Date 12/06/14
Qty Unit Charge Per Extension
BASE FEE 95.75
4.00 14.0000 THOU BL-2001-25K (14 PER K) 56.00
-----------------------------------
Other Fees . . . . . . . . . STATE SURCHARGE 4.50
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
Permit Fee Total 151.75 151.75 .00 . .00
Plan Check Total .00 .00 .00 .00
Other Fee Total 4.50 4.50 .00 .00
Grand Total 156.25 156.25 .00 .00
Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes
V null and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned
for a period of 180 days after the work has commenced, or if required inspections have not been requested within 180 days from the
last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions
of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does
not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construction.
L.— , Z—/ / y tv �� asp n
\ Date Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder)
Tforms/Building Division/Building Permit
BUILDING PERMIT INSPECTION RECORD a?
. a
— PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS--
Building Inspections 417-4815 Electrical Inspections 417-4735 �-
Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886
IT IS UNLAWFUL TO COVER,INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. G
POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE.
Inspection Type Date Accepted By Comments
FOUNDATION:
Footings
Stemwall
Foundation Drainage/Downspouts
Piers
Post Holes(Pole Bldgs.)
PLUMBING:
Under Floor/Slab
Rough-In
Water Line Meter to Bldg)
Gas Line
Back Flow/Water FINAL Date Accepted b
AIR SEAL:
Walls
Ceiling
FRAMING:
Joists/Girders/Under Floor
Shear Wall/Hold Downs
Walls/Roof/Ceiling
Drywall interior Braced Panel Only)
T-Bar
INSULATION:
Slab
Wall/Floor/Ceiling
MECHANICAL:
Heat Pum /Furnace/FAU/Ducts
Rough-in
Gas Line
Wood Stove/Pellet/Chimney
Commercial Hood/Ducts FINAL Date Accepted b
MANUFACTURED HOMES:
4
Footing/Slab
Blocking&Hold Downs
Skirting
PLANNING DEPT. Separate Permit#s SEPA: <
0
Parkin /Lighting ESA:
Landscaping SHORELINE: { Nl
3
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE ,
Inspection Type Date Accepted Byn
Electrical 417-4735 ' 1
Construction-R.W. PW /Engineering 417-4831
Fire 417-4653 a
Planning 417-4750
Building 417-4815
T:Forms/Building Division/Building Permit
THE For City Use
CITY OF y a$.• k:
Permit#
W A s H 1 N G T o N. U. S. Date Received:
321 E 51h Street Date Approved
Port Angeles,WA 9836
P:360-417-4817 F:360-417-4711
Email:permits Ocityofpa.us BUILDING PERMIT APPLICATION
Project Address: l ���k v'�Sfi ��L� ������ l�(� �� jt)(A
Phone: 3 G a L Y3 Z z 7 z
Primary Contact: Gi n Gl e tv e Iq Email:
Name Phone
Property Mailing Address Email
Owner
City State Zip
Na C PSL f- Phone i 8-3 2 2 7 Z
Contractor Add re ,C O_ _,o Email C9
Information city /� C � C jC Z State _C� Zip
Lcontractor,ficense# VO 6 f 114 Exp.Date: 1-7 _ j y
Legal Description: Zoning: Tax Parcel# Project Value: (materials and labor)
$ 5—e-7 / , Ov
' Residential Commercial ❑ Industrial ❑ Public ❑
Permit Demolition ❑ Fire ❑ Repair Reroof(tear /lay ove ) IM ,e tCZ7�
Classification For the following.fill out both pages of permit application:
(check New Construction ❑ Exterior Remodel ❑ Addition ❑ Tenant Improvement ❑
appropriate) Mechanical ❑ Plumbing ❑ Other ❑
Will a fire sprinkler system be installedIrrigation System? Proposed Bathrooms Proposed Bedrooms
or modified? Yes 13No 13 Yes ❑ No ❑
Project Description
Is project in a Flood Zone: Yes a NoE� Flood Zone Type:
If in a Flood Zone, what is the value of the structure before proposed improvement? $
I have.read and completed the application and know it to be true and correct. I am authorized to apply for
this permit and understand that it is my responsibility to determine what permits are required and to
obtain permits prior to work. I understand that plan review fees are not refundable after review has
occurred. I understand that I will forfeit review fees if I withdraw the application before the permit is
issued. I understand that if the permit isnot picked up/issued within i8o days of submittal,the application
will be considered abandoned and the fees will be forfeited.
.6- �9_ i y Ck(P 11 w L 10 S-e
Date Print Name Signature
Residential Structures
For Office Use
Area Description(SQ FT) Existing Proposed $$value
Basement
First Floor
Second Floor
Covered Deck/Porch/Entry
Deck(over 30"or a° floor)
Garage
Carport
Other(describe)
Area Totals
Commercial Structures
Proposed For Office Use
Area Descriptions(SQ FT) Existing Proposed ss Value
Existing Structure(s)
Proposed Addition
Tenant Improvement?
Other work(describe)
Site Area Totals
•
Lot/Site Coverage Calculations
Lot Size (sq ft) Lot Coverage(sq ft) %Lot Coverage(Total lot coverage=lot size)
Site Coverage(Sq Ft of all impervious) %of Site Coverage(total site coverage_lot size)
Mechanical Fixtures
Indicate how many of each-type of fixture to be installed or relocated as part of this project.
Air Handler Size: # Haz/Non-Haz Piping Outlets:
Appliance Exhaust Fan # Heater(Suspended,Floor,Recessed wall) #
Boiler/Compressor Size: # Heating/Cooling appliance #
re
ration
Evaporative
Evaporative Cooler(attached,not # Pellet Stove/Wood-burning/Gas #
portable) Fireplace Gas Stove/Gas Cook Stove/Misc.
Fuel Gas Piping #of Outlets: Ventilation Fan,single duct #
Furnace/Heat Pump/ Size: # Ventilation System #
Forced Air Unit I ,
Plumbing Fixtures
Indicate how many of each type of fixture to be installed or relocated
Plumbing Traps # Fuel gas piping #of Outlets:
Water Heater # Medical gas piping #of Outlets:
Water Line # Plumbing Vent piping #
Sewer Line # Industrial waste pretreatment
interceptor Grease Trap) Size
Other(describe):
T:\BUILDING\APPLICATION FORMS\Current BP Application\Building Permit 4-17.13.docx
Application Number . . . . . 23-00001288 Date 12/06/23
Application pin number . . . 232648
Property Address . . . . . . 111 OAKCREST AVE
ASSESSOR PARCEL NUMBER: 06-30-16-5-3-0010-0000-
Application type description ELECTRICAL ONLY
Subdivision Name . . . . . .
Property Use . . . . . . . .
Property Zoning . . . . . . . RS7 RESDNTL SINGLE FAMILY
Application valuation . . . . 0
----------------------------------------------------------------------------
Application desc
PV system
----------------------------------------------------------------------------
Owner Contractor
------------------------ ------------------------
SUZANNE MARIE MCCOY LUMIO HX, INC
111 OAKCREST AVE 1550 W DIGITAL DR
PORT ANGELES WA 983626928 LEHI UT 84043
(360) 909-4508 (360) 637-4343
----------------------------------------------------------------------------
Permit . . . . . . ELECTRICAL ALTER RESIDENTIAL
Additional desc . .
Permit Fee . . . . 120.00 Plan Check Fee . . .00
Issue Date . . . . 12/06/23 Valuation . . . . 0
Expiration Date . . 6/03/24
Qty Unit Charge Per Extension
1.00 120.0000 ECH EL-0-200 SRV FEEDER 120.00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 120.00 120.00 .00 .00
Plan Check Total .00 .00 .00 .00
Grand Total 120.00 120.00 .00 .00
Public Works and Utilities Department
321 E. 5th Street, Port Angeles, WA 98362
360.417.4735 | www.cityofpa.us | electricalpermits@cityofpa.us
EL1-2 SF 1 - 2 SINGLE-FAMILY
ELECTRICAL PERMIT APPLICATION
Project Address:
Project Description:
Ƒ Single-Family Residential Ƒ Duplex / ARU Building Square footage:
OWNER INFORMATION
Name: Email:
Mailing Address: Phone:
ELECTRICAL CONTRACTOR INFORMATION
Name: License:
Mailing Address: Expiration Date:
Email: Phone:
PROJECT DETAILS
Item Unit Charge Quantity Total (Quantity x Unit Charge)
Service/Feeder 200 Amp. $120.00 $
Service/Feeder 201-400 Amp. $146.00 $
Service/Feeder 401-600 Amp. $205.00 $
Service/Feeder 601-1000 Amp. $262.00 $
Service/Feeder over 1000 Amp. $373.00 $
Branch Circuit W/ Service Feeder $5.00 $
Branch Circuit W/O Service Feeder $63.00 $
Each Additional Branch Circuit $5.00 $
Branch Circuits 1-4 $75.00 $
Temp. Service/Feeder 200 Amp. $93.00 $
Temp. Service/Feeder 201-400 Amp. $110.00 $
Temp. Service/Feeder 401-600 Amp. $149.00 $
Temp. Service/Feeder 601-1000 Amp. $168.00 $
Portal to Portal Hourly $96.00 $
Signal Circuit/Limited Energy - 1&2 DU. $64.00 $
Manufactured Home Connection $120.00 $
Renewable Elec. Energy: 5KVA System or less $102.00 $
Thermostat (Note: $5 for each additional) $56.00 $
First 1300 Square Feet $120.00 $
Each Additional 500 square feet`` $40.00 $
Each Outbuilding / Detached Garage $74.00 $
Each Swimming Pool / Hot Tub $110.00 $
TOTAL $
2ZQHUDVGH¿QHGE\5&:2ZQHUZLOORFFXS\WKHVWUXFWXUHIRUWZR\HDUVDIWHUWKLVHOHFWULFDOSHUPLWLV¿QDOL]HG2ZQHULV
required to hire an electrical contractor if above said property is for sale, rent or lease. Permit expires after six months of last inspection.
After reading the above statement, I hereby certify that I am the owner of the above named property or a licensed electrical contractor. I
am making the electrical installation or alteration in compliance with the electrical laws, N.E.C., RCW. Chapter 19.28, WAC. Chapter 296-
%7KH&LW\RI3RUW$QJHOHV0XQLFLSDO&RGHDQG8WLOLW\6SHFL¿FDWLRQVDQG3$0&UHJDUGLQJ(OHFWULFDO3HUPLW$SSOLFDWLRQV
Date Print Name Signature (ƑOwner ƑElectrical Contractor / Administrator)
Pe
r
m
i
t
#
:
New
Construction
Only
[Electrical Permit Applications may be submitted to City Hall or electricalpermits@cityofpa.us or faxed to 360.417.4711]
QVDQG3$0&UHJD
ture (ƑOwner ƑElect
111 West Oakcrest Avenue Port Angeles, Washington 98362
3.20kWDC Rooftop Photovoltaic Solar Installation
✔1,264
Suzanne Mccoy mccoys4567@yahoo.com
111 West Oakcrest Avenue Port Angeles, Washington 98362 (360) 909-4508
Lumio HX, Inc LUMIOHI78K4
2500 Mottman RD SW Tumwater WA 98512 1/04/25
PNW.Permitting@Lumio.com 360-777-6681
1 120
120
12/05/2023 Jesus Familia
✔
PREPARED 12/05/23,13:39:15 PAYMENT DUE
CITY OF PORT ANGELES PROGRAM BP820L
---------------------------------------------------------------------------
APPLICATION NUMBER:23-00001288 111 OAKCREST AVE
FEE DESCRIPTION AMOUNT DUE
---------------------------------------------------------------------------
ELECTRICAL ALTER RESIDENTIAL 120.00
TOTAL DUE 120.00
Please present reciept to the cashier with full payment
COVER SHEET
PHOTOVOLTAIC ROOF MOUNT SYSTEM
111 W OAKCREST AVE, PORT ANGELES, WA 98362, USA
REVDATEDESCRIPTION
VERSION
UR04/11/2023INITIAL RELEASE
SHEET NAME
SHEET NUMBER
PV-0
PROJECT NAME
SHEET SIZE
ANSI B
11" X 17"
SU
Z
A
N
N
E
M
C
C
O
Y
11
1
W
O
A
K
C
R
E
S
T
A
V
E
,
PO
R
T
A
N
G
E
L
E
S
,
WA
9
8
3
6
2
,
U
S
A
AP
N
#
06
3
0
1
6
5
3
0
0
1
0
0
0
0
0
UT
I
L
I
T
Y
:
CI
T
Y
O
F
P
O
R
T
A
N
G
E
L
E
S
AH
J
:
CI
T
Y
O
F
P
O
R
T
A
N
G
E
L
E
S
PR
O
J
E
C
T
N
U
M
B
E
R
:
P-
0
0
9
0
3
5
9
08 MODULES-ROOF MOUNTED - 3.200 kWDC, 2.320 kWAC
GOVERNING CODES:
2020 NATIONAL ELECTRICAL CODE (NEC)
2018 INTERNATIONAL BUILDING CODE
2018 INTERNATIONAL EXISTING BUILDING CODE
2018 INTERNATIONAL SWIMMING POOL AND SPA CODE
2018 INTERNATIONAL FIRE CODE
2018 WASHINGTON STATE ENERGY CODE
2018 INTERNATIONAL RESIDENTIAL CODE
2018 INTERNATIONAL MECHANICAL CODE
2018 UNIFORM PLUMBING CODE
2 VICINITY MAP
SCALE: NTSPV-0
1 AERIAL PHOTO
SCALE: NTSPV-0
SHEET INDEX
PV-0 COVER SHEET
PV-1 SITE PLAN WITH ROOF PLAN
PV-2 ROOF PLAN WITH MODULES
PV-3 ATTACHMENT DETAILS
PV-4 ELECTRICAL LINE DIAGRAM WITH
CALCULATION
PV-5 WARNING LABELS & PLACARD
PV-6 SAFETY PLAN
PV-7+EQUIPMENT SPEC SHEETS
NOTES:
1.PHOTOVOLTAIC SYSTEM EQUIPMENT SHALL BE INSTALLED IN
ACCORDANCE WITH NEC 2020 ARTICLES 690 AND 705, AND THE 2018
IRC/IBC & 2018 INTERNATIONAL FIRE CODE, AND APPLICABLE
REQUIREMENTS OF THE SERVICE UTILITY AND AUTHORITY HAVING
JURISDICTION. PHOTOVOLTAIC SYSTEM EQUIPMENT WILL BE POSTED
WITH APPLICABLE WARNINGS, SIGNAGE AND PLAQUES PER NEC 690.13,
705.10 AND 706.15.
2.PHOTOVOLTAIC SOURCE AND OUTPUT CIRCUITS SHALL COMPLY WITH
THE WIRING METHODS AND INSTALLATION AND MARKING
REQUIREMENTS OF NEC 690.31(D).
3.BREAKER LABELED "PHOTOVOLTAIC ELECTRIC POWER SOURCE" AND
"BREAKERS ARE BACK FED" PER NEC 705.12(D) & NEC 690.59. BREAKER
ALSO LABELED "MAXIMUM AC OUTPUT CURRENT AND OPERATING AC
VOLTAGE" PER NEC 690.54. BREAKER SHALL BE POSITIONED AT THE
OPPOSITE (LOAD) END FROM THE INPUT FEEDER OR MAIN CIRCUIT
BREAKER LOCATION, AND LABELED "WARNING INVERTER OUTPUT
CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE", PER
NEC 705.12 (B)(3)(2).
4.WARNING SIGN PER NEC 706.15(C)(4) and NEC 690.13(B) READING
"WARNING - ELECTRIC SHOCK HAZARD - TERMINALS ON BOTH LINE AND
LOAD SIDES MAY BE ENERGIZED IN THE OFF POSITION."
5.LABEL "PHOTOVOLTAIC SYSTEM UTILITY DISCONNECT SWITCH." SWITCH
TO BE LOCKED PER NEC 690.13(B). SWITCH TO BE VISIBLE BLADE
DISCONNECT PER UTILITY REQUIREMENTS AND CONFORM TO NEC
705.22.
6.LABEL "PHOTOVOLTAIC ARRAY DC DISCONNECT SWITCH" PER NEC
690.13(B). LABEL WITH OPERATING CURRENT, OPERATING VOLTAGE,
MAXIMUM SYSTEM VOLTAGE, AND SHORT CIRCUIT CURRENT PER NEC
690.53. SWITCH LOCKED PER NEC 690.13(B).
7.LISTING AGENCY NAMES AND NUMBERS TO BE INDICATED ON POWER
INVERTER(S) AND SOLAR MODULES PER NEC 110.3 (B).
8.LABELED PHOTOVOLTAIC SYSTEM DEDICATED KWH METER. (NOT USED)
9.BI-DIRECTIONAL METER TO BE INSTALLED BY UTILITY.
10.DEDICATED PHOTOVOLTAIC COMBINER SUB-PANEL. LABEL "LOADS NOT
TO BE ADDED TO THIS PANEL."
11.ALL LABELS EXPOSED TO SUNLIGHT MUST BE ENGRAVED AND
ATTACHED PER APPROVED METHOD.
12.LABEL "BREAKER HAS BEEN DE-RATED PER NEC 705.12(D)(2)." NO NEW
LOADS.
13.EXISTING EQUIPMENT IS NOTED WITH A DASHED LINE. SOLID LINES
DENOTE EQUIPMENT INSTALLED BY ELECTRICAL CONTRACTOR.
14.WIRE MAY BE RUN SHORT DISTANCES OUTSIDE OF CONDUIT IF WIRE
READS "SUNLIGHT RESISTANT."
15.THE GROUNDING ELECTRODE CONDUCTOR SHALL BE CONTINUOUS AND
TERMINATE WITH AN IRREVERSIBLE CONNECTION TO THE AC
GROUNDING ELECTRODE SYSTEM PER NEC 250.64(B).
16.AMBIENT TEMPERATURE ADJUSTED FOR CONDUITS EXPOSED TO
SUNLIGHT ON OR ABOVE ROOFTOPS PER TABLE 310.15 (B)(2). CONDUIT
ELEVATED MIN. 1/2"; ADDER 33 DEG F.
17.ALL EXTERIOR EQUIPMENT TO BE NEMA 3R.
18.THE PHOTOVOLTAIC POWER SOURCE SHALL BE LABELED WITH THE
FOLLOWING WARNING AT EACH JUNCTION BOX, COMBINER BOX,
DISCONNECT AND DEVICE WHERE ENERGIZED, UNGROUNDED CIRCUITS
MAY BE EXPOSED DURING SERVICE:
WARNING: ELECTRIC SHOCK HAZARD. THE DC CONDUCTORS OF THIS
PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED
SYSTEM SUMMARY:
(N) 08 - HANWHA Q CELLS Q.PEAK DUO BLK ML-G10+ / t (400W) MODULES
(N) 08 - ENPHASE ENERGY IQ8PLUS-72-2-US MICRO-INVERTERS [240V]
(N) JUNCTION BOX
(E) 200A MAIN SERVICE PANEL WITH (E) 200A MAIN BREAKER
(N) ENPHASE IQ COMBINER 4 [240V]
X2-IQ-AM1-240-4 (IEEE 1547:2018)
(N) 60A FUSED AC DISCONNECT [240V]
ROOF TYPE: - ASPHALT SHINGLES
NUMBER OF LAYERS: - 01
ROOF FRAME: - 2"X6" TRUSSES @ 24" O.C.
STORY: - ONE STORY
SNOW LOAD : - 25 PSF
WIND SPEED :- 110 MPH
WIND EXPOSURE:- C
RISK CATEGORY:- II
COORDINATE:- 48.099718, -123.446284
DESIGN CRITERIA:
UTILITY METER NO: 28 356 811
AC
D
MS
P
UM
JB
CB
~89.68'
~9
5
.
1
6
'
~9
5
.
1
6
'
~89.68'
15'-2"
31
'
-
0
"
15
'
-
1
1
"
17'-5"
AC
D
MS
P
UM
JB
CB
SITE PLAN WITH ROOF PLAN
REVDATEDESCRIPTION
VERSION
UR04/11/2023INITIAL RELEASE
SHEET NAME
SHEET NUMBER
PV-1
PROJECT NAME
SHEET SIZE
ANSI B
11" X 17"
SU
Z
A
N
N
E
M
C
C
O
Y
11
1
W
O
A
K
C
R
E
S
T
A
V
E
,
PO
R
T
A
N
G
E
L
E
S
,
WA
9
8
3
6
2
,
U
S
A
AP
N
#
06
3
0
1
6
5
3
0
0
1
0
0
0
0
0
UT
I
L
I
T
Y
:
CI
T
Y
O
F
P
O
R
T
A
N
G
E
L
E
S
AH
J
:
CI
T
Y
O
F
P
O
R
T
A
N
G
E
L
E
S
PR
O
J
E
C
T
N
U
M
B
E
R
:
P-
0
0
9
0
3
5
9
SITE PLAN WITH
ROOF PLAN
1 SCALE: 1/16" = 1'-0"
ROOF ACCESS POINT SHALL BE LOCATED IN AREAS THAT DO NOT REQUIRE THE
PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS WINDOWS OR
DOORS, AND LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION IN
LOCATIONS WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD
OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES OR SIGNS.
NOTE: THE AC DISCONNECT IS LOCATED
WITHIN 10FT OF UTILITY METER
NOTE:
3/4" OR GREATER EMT CONDUIT
RUN (7/8" ABOVE ROOF SURFACE)
LEGEND
JUNCTION BOXJB
MSP MAIN SERVICE PANEL
GATE
FENCE
TREES
ENPHASE IQ COMBINER 4
X2-IQ-AM1-240-4 (IEEE 1547:2018)CB
UTILITY METERUM
VENT, ATTIC FAN (ROOF OBSTRUCTION)
PROPERTY LINE
AC DISCONNECTACD
W OAKCREST AVE
ONE- STORY
HOUSE
EXISTING
DRIVEWAY
(E) STRUCTURE
ROOF ACCESS POINT
AC
D
MS
P
UM
JB
CB
4'-5"20'-3"11'-8"
1'
-
3
"
8'
-
1
1
"
2'
-
6
"
REVDATEDESCRIPTION
VERSION
UR04/11/2023INITIAL RELEASE
SHEET NAME
SHEET NUMBER
PV-2
PROJECT NAME
SHEET SIZE
ANSI B
11" X 17"
SU
Z
A
N
N
E
M
C
C
O
Y
11
1
W
O
A
K
C
R
E
S
T
A
V
E
,
PO
R
T
A
N
G
E
L
E
S
,
WA
9
8
3
6
2
,
U
S
A
AP
N
#
06
3
0
1
6
5
3
0
0
1
0
0
0
0
0
UT
I
L
I
T
Y
:
CI
T
Y
O
F
P
O
R
T
A
N
G
E
L
E
S
AH
J
:
CI
T
Y
O
F
P
O
R
T
A
N
G
E
L
E
S
PR
O
J
E
C
T
N
U
M
B
E
R
:
P-
0
0
9
0
3
5
9
ROOF PLAN WITH
MODULES
ROOF PLAN WITH MODULES
SCALE: 1/8" = 1'-0"1
MODULE TYPE, DIMENSIONS & WEIGHT
NUMBER OF MODULES = 08 MODULES
MODULE TYPE = HANWHA Q CELLS Q.PEAK DUO BLK ML-G10+ / t
(400W) MODULES
MODULE WEIGHT = 48.5 LBS / 22.0 KG.
MODULE DIMENSIONS = 74.0"X 41.1" = 21.12 SF
UNIT WEIGHT OF ARRAY = 2.30 PSF
NOTE: ACTUAL ROOF CONDITIONS AND
TRUSSES LOCATIONS MAY VARY. INSTALL
PER MANUFACTURER(S) INSTALLATION
GUIDELINES AND ENGINEERED SPANS FOR
ATTACHMENTS
· PLUMBING VENTS, SKYLIGHTS AND MECHANICAL VENTS SHALL
NOT BE COVERED, MOVED, RE-ROUTED OR RE-LOCATED.
NOTE: THE AC DISCONNECT IS LOCATED
WITHIN 10FT OF UTILITY METER
NOTE:
3/4" OR GREATER EMT CONDUIT
RUN (7/8" ABOVE ROOF SURFACE)
ARRAY AREA & ROOF AREA CALC'S
AREA OF NEW ARRAY
(Sq. Ft.)
AREA OF ROOF(PLAN
VIEW)
(Sq. Ft.)
TOTAL ROOF AREA
COVERED BY ARRAY %
168.97 2184.72 7.73%
ARRAY AREA & ROOF AREA CALC'S
ROOF # OF
MODULES
ARRAY
AREA
(Sq. Ft.)
ROOF
AREA
(Sq. Ft.)
ROOF
AREA
COVERED BY
ARRAY (%)
#1 08 168.97 380.05 44.46
ROOF DESCRIPTION
ROOF TYPE ASPHALT SHINGLES
ROOF
ROOF ROOF
TILT AZIMUTH TRUSSES
SIZE
TRUSSES
SPACING
#1 23°181°2"x6"24" O.C.
LEGEND
VENT, ATTIC FAN
(ROOF OBSTRUCTION)
ROOF ATTACHMENT UNIRAC STRONGHOLD
BUTYL @ 48", 72" O.C.
TRUSSES
JUNCTION BOXJB
MSP MAIN SERVICE PANEL
FIRE PATHWAY
UNIRAC NXT UMOUNT RAIL
ENPHASE ENERGY IQ8PLUS-72-2-US
MICRO-INVERTERS
ENPHASE IQ COMBINER 4
X2-IQ-AM1-240-4 (IEEE 1547:2018)CB
UTILITY METERUM
AC DISCONNECTACD
BILL OF MATERIALS
EQUIPMENT QTY DESCRIPTION
RAIL 06 UNIRAC NXT UMOUNT RAIL 168" DRK
RAIL SPLICE 02 NXT UMOUNT RAIL SPLICE
UNIVERSAL CLAMP 22 NXT UMOUNT COMBO CLAMP DRK
ROOF
ATTACHMENTS 22 UNIRAC STRONGHOLD BUTYL
ACCESSORIES 12 NXT UMOUNT RL & CLMP CAP KIT
MLPE & GROUNDING 11 NXT UMOUNT MLPE & LUG CLAMP
W OAKCREST AVE
FRONT YARD
REAR YARD
18" FIRE PATHWAY
18" FIRE PATHWAY
1
8
"
F
I
R
E
P
A
T
H
W
A
Y
1
8
"
F
I
R
E
P
A
T
H
W
A
Y
36
"
F
I
R
E
P
A
T
H
W
A
Y
ROOF #1
REVDATEDESCRIPTION
VERSION
UR04/11/2023INITIAL RELEASE
SHEET NAME
SHEET NUMBER
PV-3
PROJECT NAME
SHEET SIZE
ANSI B
11" X 17"
SU
Z
A
N
N
E
M
C
C
O
Y
11
1
W
O
A
K
C
R
E
S
T
A
V
E
,
PO
R
T
A
N
G
E
L
E
S
,
WA
9
8
3
6
2
,
U
S
A
AP
N
#
06
3
0
1
6
5
3
0
0
1
0
0
0
0
0
UT
I
L
I
T
Y
:
CI
T
Y
O
F
P
O
R
T
A
N
G
E
L
E
S
AH
J
:
CI
T
Y
O
F
P
O
R
T
A
N
G
E
L
E
S
PR
O
J
E
C
T
N
U
M
B
E
R
:
P-
0
0
9
0
3
5
9
ATTACHMENT
DETAIL
ATTACHMENT DETAIL
SCALE: NTS1
ATTACHMENT DETAIL (ENLARGED VIEW)
SCALE: NTS2
NOTE: ACTUAL ROOF CONDITIONS AND TRUSSES (OR SEAM)
LOCATIONS MAY VARY. INSTALL PER MANUFACTURER(S)
INSTALLATION GUIDELINES AND ENGINEERED SPANS FOR
ATTACHMENTS
(E) 2"X6"
TRUSS
E
S
@ 24" O.CENLARGE VIEW
(N) PV MODULES
(E) ASPHALT SHINGLES ROOF
(N) NXT UMOUNT COMBO CLAMP
(N) PV MODULES
(N) NXT UMOUNT RAIL
(N) NXT UMOUNT RAIL CLAMP ASSY
(E) ROOF / DECK MEMBRANE
(E) ASPHALT SHINGLES ROOF
5/16"-18 x 2"
SERRATED FLANGE HEX SCREW
~4
"
~
4
"
1-3/4" MIN.
EMBEDMENT
1
.
2
6
"
1.
2
6
"
(N) DTD BUTYL ATT ASSY (1/8" BUTYL)
2X12-14 SCREW, HWH, SS, SELF-DR
W/ #12 EPDM WASHER
(N) STRONGHOLD BUTYL ATTACHMENTS, DRK
REVDATEDESCRIPTION
VERSION
UR04/11/2023INITIAL RELEASE
SHEET NAME
SHEET NUMBER
PV-4
PROJECT NAME
SHEET SIZE
ANSI B
11" X 17"
SU
Z
A
N
N
E
M
C
C
O
Y
11
1
W
O
A
K
C
R
E
S
T
A
V
E
,
PO
R
T
A
N
G
E
L
E
S
,
WA
9
8
3
6
2
,
U
S
A
AP
N
#
06
3
0
1
6
5
3
0
0
1
0
0
0
0
0
UT
I
L
I
T
Y
:
CI
T
Y
O
F
P
O
R
T
A
N
G
E
L
E
S
AH
J
:
CI
T
Y
O
F
P
O
R
T
A
N
G
E
L
E
S
PR
O
J
E
C
T
N
U
M
B
E
R
:
P-
0
0
9
0
3
5
9
ELECTRICAL LINE
DIAGRAM &
CALCULATION
ELECTRICAL LINE DIAGRAM WITH CALCULATION
SCALE: NTS1
L
200A
(E) MAIN BREAKER
200A/2P, 240V
(E) MAIN
SERVICE PANEL,
200A RATED,
120/240V
EXISTING
GROUNDING
SYSTEM
BI-DIRECTIONAL
UTILITY METER
1-PHASE, 3-W,
120V/240V, 60Hz
(N) 60A FUSED AC
DISCONNECT, WITH 20A
FUSES,
240 VAC
G
N N
L2
L1
L2
L1
20A FUSES
AC DISCONNECT SHALL BE
LOCATED WITHIN 10' OF
UTILITY METER
LINE SIDE
CONNECTION
NOTE-TAP CONDUCTORS SHALL BE 10' OR
LESS PER NEC 705.31
C
NOTE: THE AC DISCONNECT IS LOCATED
WITHIN 10FT OF UTILITY METER
·GAS METER LOCATED IN PROXIMITY OF THE PV INSTALLATION, LOAD CENTER, AND/OR
DISCONNECTS. DISCONNECTS SHALL BE LOCATED IN COMPLIANCE WITH UTILITY AND THE AHJ
(AUTHORITY HAVING JURISDICTION). PV INSTALLATION SHALL COMPLY WITH ALL APPLICABLE
CODES.
·WIRE RATED AND AMPACITY CALCULATED @ 90°C FOR ROOFTOP INSTALLATION AND ATTIC RUN
TO INVERTER.
·PER NEC REQUIRMENTS GROUNDING CONDUCTORS SMALLER THAN 6AWG SHALL BE
PROTECTED IN A CONDUIT, RACEWAY, OR ARMORED PROTECTIVE SHEATHING (NEC 250.64).
·THE WORKING CLEARANCES AROUND THE EXISTING ELECTRICAL EQUIPMENT AS WELL AS THE
NEW ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN ACCORDANCE WITH NEC 110.26.
·ANY CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT. (NEC
300.6 C1, 310.8 D).
·ROOM FOR EQUIPMENT WITHIN 5 FEET FROM MSP.
·ALL CONDUIT SHALL BE EMT 3/4" IN DIAMETER UNLESS OTHERWISE STATED.
·CONFIGURE FOR IEEE 1547 ANTI-ISLANDING GRID PROFILE.
UTILITY PROVIDER:
MAIN SERVICE VOLTAGE:
MAIN PANEL BRAND:
MAIN SERVICE PANEL:
MAIN CIRCUIT BREAKER RATING:
MAIN SERVICE LOCATION:
SERVICE FEED SOURCE:
CITY OF PORT ANGELES
240V
CUTLER-HAMMER
(E) 200A
(E) 200A
WEST
SERVICE INFO.
OVERHEAD
NOTE:
3/4" OR GREATER EMT CONDUIT
RUN (7/8" ABOVE ROOF SURFACE)
SYSTEM SIZE:- 08 x 400W = 3.200 kWDC
08 x 290VA = 2.320 kWAC
INVERTER SPECIFICATIONS
MANUFACTURER / MODEL #QUANTITY NOMINAL OUTPUT
VOLTAGE
NOMINAL OUTPUT
CURRENT
ENPHASE ENERGY
IQ8PLUS-72-2-US 08 240 VAC 1.21A
(08) ENPHASE ENERGY
IQ8PLUS-72-2-US
MICRO-INVERTERS (240V)
(LOCATED UNDER EACH PANEL)
(N) JUNCTION BOX
G
N
G
TERMINATOR CAP ON LAST CABLE
CONNECTOR Q- CABLE (TYP)
10A/15A
M*IQ-GATEWAY
20A
08 MICRO-INVERTERS IN BRANCH #1
L1L1
L2L2
(N) ENPHASE IQ
COMBINER BOX 4
X2-IQ-AM1-240-4
(IEEE1547:2018) [240V]
A B
AMBIENT TEMPERATURE SPECIFICATIONS
RECORD
LOW TEMP
AMBIENT TEMP
(HIGH TEMP 2%)
CONDUCTOR
TEMPERATURE
RATE
-6°25°90°
NOTE-EQUIPMENT RATED AT 75 DEGREES
Wire Tag Conduit Wire Qty Wire
Gauge Wire Type Temp.
Rating
Wire
Ampacity (A)
Temp.
Derate
Conduit
Fill Derate
Derated
Ampacity (A)
Inverter
Qty NOC (A)NEC
Correction
Design
Current (A)
Ground
Size
Ground Wire
Type
A OPEN AIR 1 12 AWG Q Cable 90°C 30 1.04 N/A 31.20 08 1.21 1.25 12.10 06 AWG BARE CU
B 3/4" EMT 2 12 AWG THWN-2 90°C 30 1.04 1.0 31.20 08 1.21 1.25 12.10 06 AWG THWN-2
C 3/4" EMT 3 6 AWG THWN-2 90°C 75 1.04 1.0 78.00 08 1.21 1.25 12.10 06 AWG THWN-2
D 3/4" PVC 3 6 AWG THWN-2 90°C 75 1.04 1.0 78.00 08 1.21 1.25 12.10 06 AWG THWN-2
UTILITY METER NO: 28 356 811
SOLAR MODULE SPECIFICATIONS
MANUFACTURER / MODEL #VMP
(V)
IMP
(A)
VOC
(V)
ISC
(A)
TEMPERATURE
COEFFICIENT
OF Voc
# OF
MODULES
HANWHA Q CELLS Q.PEAK DUO
BLK ML-G10+ / t (400W)38.09 10.50 45.55 11.07 -0.27%/K 08
MODULE DIMENSION 74.0" L x 41.1" W x 1.26" D
D
REVDATEDESCRIPTION
VERSION
UR04/11/2023INITIAL RELEASE
SHEET NAME
SHEET NUMBER
PV-5
PROJECT NAME
SHEET SIZE
ANSI B
11" X 17"
SU
Z
A
N
N
E
M
C
C
O
Y
11
1
W
O
A
K
C
R
E
S
T
A
V
E
,
PO
R
T
A
N
G
E
L
E
S
,
WA
9
8
3
6
2
,
U
S
A
AP
N
#
06
3
0
1
6
5
3
0
0
1
0
0
0
0
0
UT
I
L
I
T
Y
:
CI
T
Y
O
F
P
O
R
T
A
N
G
E
L
E
S
AH
J
:
CI
T
Y
O
F
P
O
R
T
A
N
G
E
L
E
S
PR
O
J
E
C
T
N
U
M
B
E
R
:
P-
0
0
9
0
3
5
9
WARNING LABELS &
PLACARD
POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE
FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN
11
1
W
O
A
K
C
R
E
S
T
A
V
E
(E) 200A MAIN SERVICE PANEL
WITH (E) 200A MAIN BREAKER
(E) UTILITY METER
(N) 60A FUSED AC DISCONNECT
(N) ENPHASE IQ COMBINER BOX 4
(N) PV MODULES
CAUTION !
MULTIPLE SOURCES OF POWER
WARNING DUAL POWER SOURCE
SECOND SOURCE IS PHOTOVOLTAIC SYSTEM
LABEL LOCATION:
EMT/CONDUIT RACEWAYS
(PER CODE: NEC690.31(D)(2)
PHOTOVOLTAIC POWER SOURCE
LABEL LOCATION:
POINT OF INTERCONNECTION
PRODUCTION METER
NEC 705.12(D)(3) & NEC 690.59)
NOTES AND SPECIFICATIONS:
·SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE
2020 ARTICLE 110.21(B), UNLESS SPECIFIC INSTRUCTIONS
ARE REQUIRED BY SECTION 690, OR IF REQUESTED BY THE
LOCAL AHJ.
·SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS
USING EFFECTIVE WORDS, COLORS AND SYMBOLS.
·LABELS SHALL BE PERMANENTLY AFFIXED TO THE
EQUIPMENT OR WIRING METHOD AND SHALL NOT BE HAND
WRITTEN.
·LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND
THE ENVIRONMENT INVOLVED.
·SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011,
PRODUCT SAFETY SIGNS AND LABELS, UNLESS OTHERWISE
SPECIFIED.
·DO NOT COVER EXISTING MANUFACTURER LABELS.
ELECTRICAL SHOCK HAZARD
WARNING
TERMINALS ON LINE AND LOAD
SIDES MAY BE ENERGIZED IN
THE OPEN POSITION
LABEL LOCATION:
INVERTER(S), AC DISCONNECT(S), AC
COMBINER PANEL (IF APPLICABLE).
PER CODE(S): NEC 2020: NEC 690.13(B)
& NEC 690.15(C)
MAXIMUM AC OPERATING CURRENT:
NOMINAL OPERATING AC VOLTAGE:
9.68 AMPS
240 VAC
LABEL LOCATION:
AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF
INTERCONNECTION.
PER CODE(S): NEC 2020: 690.54
SOLAR PV SYSTEM EQUIPPED
WITH RAPID SHUTDOWN
SOLAR ELECTRIC
PV PANELS
TURN RAPID SHUTDOWN
SWITCH TO THE "OFF"
POSITION TO SHUT DOWN
PV SYSTEM AND REDUCE
SHOCK HAZARD IN THE
ARRAY.
!
3"
3"
PHOTOVOLTAIC SYSTEM AC DISCONNECT
MAIN PHOTOVOLTAIC
SYSTEM DISCONNECT
LABEL LOCATION:
MAIN SERVICE DISCONNECT / UTILITY METER
(PER CODE: NEC 690.13(B))
RAPID SHUTDOWN SWITCH
FOR SOLAR PV SYSTEM
!
WARNING
THE DISCONNECTION OF THE
GROUNDED CONDUCTOR(S)
MAY RESULT IN OVERVOLTAGE
ON THE EQUIPMENT
!
LABEL LOCATION:
COMBINER BOX
PER CODE: NEC 690.31(E)
PHOTOVOLTAIC
AC DISCONNECT
LABEL LOCATION:
AC DISCONNECT
NEC 690.13(B)
LABEL LOCATION:
MAIN SERVICE PANEL
PER CODE(S): NEC 2020: IFC 605.11.3.1(1) & 690.56(C)
LABEL LOCATION:
UTILITY SERVICE ENTRANCE/METER,
INVERTER/DC DISCONNECT IF REQUIRED BY
LOCAL AHJ, OR OTHER LOCATIONS (WITHIN 3 FT)
AS REQUIRED BY LOCAL AHJ.
PER CODE(S): NEC 2020: 690.56(C)(2)
REVDATEDESCRIPTION
VERSION
UR04/11/2023INITIAL RELEASE
SHEET NAME
SHEET NUMBER
PV-6
PROJECT NAME
SHEET SIZE
ANSI B
11" X 17"
SU
Z
A
N
N
E
M
C
C
O
Y
11
1
W
O
A
K
C
R
E
S
T
A
V
E
,
PO
R
T
A
N
G
E
L
E
S
,
WA
9
8
3
6
2
,
U
S
A
AP
N
#
06
3
0
1
6
5
3
0
0
1
0
0
0
0
0
UT
I
L
I
T
Y
:
CI
T
Y
O
F
P
O
R
T
A
N
G
E
L
E
S
AH
J
:
CI
T
Y
O
F
P
O
R
T
A
N
G
E
L
E
S
PR
O
J
E
C
T
N
U
M
B
E
R
:
P-
0
0
9
0
3
5
9
SAFETY PLAN
SYSTEM SIZE:- 08 x 400W = 3.200 kWDC
08 x 290VA = 2.320 kWAC
SAFETY PLAN
SCALE: NTS1
INSPECT ENTIRE JOB SITE FOR HAZARDS
SAFETY PLAN CHECKLIST ABBR.
INDICATE PARKING LOCATION FOR COMPANY VEHICLES
SD
CV
INDICATE LOCATION OF SAFETY DOCUMENTS
FIRE EXTINGUISHER LOCATION FE
H
FIRST AID KIT LOCATION FA
EYE WASH LOCATION EW
DRINKING WATER LOCATION DW
IDENTIFY HARD HAT ZONE HHZ
DRAW FALL PROTECTION ANCHOR LOCATION X
DRAW LADDER & ROOF ACCESS LOCATION L
DRAW LADDER ANCHOR LOCATION LA
IDENTIFY ELECTRICAL HAZARD AREAS EH
INDICATE OTHER HAZARD LOCATION AND SPECIFY
(E.G. WATER,TRIPPING,ANIMALS,INSECTS,ETC.)
WEATHER FORECAST
HOURLY
HEAT INDEX HIPP MEASURES
7 AM
8 AM
9 AM
10 AM
11 AM
12 AM
1 AM
2 AM
3 AM
4 AM
5 AM
OTHER WEATHER RELATED HAZARDS & MEASURES
WET OR ICY SURFACES
HIGH WINDS
THUNDER STOMS
WILDFIRE SMOKE
OTHER
ADDRESS & PHONE NUMBER OF CLOSEST URGENT CARE FACILTY
CREW LEAD SIGNATURE & DATE(S)
CREW LEAD SIGNATURE & DATE(S)
NOTE: CREW LEAD MUST CONDUCT A DAILY MEETING TO REVIEW ALL SAFTEY ITEMS.
1
2
3
4
5
NOTE: FOR MULTIPLE DAY JOBS,SAFETY MEETINGS MUST BE CONDUCTED EACH DAY.
INDICATE BY INITIALING NEXT TO YOUR SIGNATURE FOR EACH ADDITIONAL DAY.
W OAKCREST AVE
REVDATEDESCRIPTION
VERSION
UR04/11/2023INITIAL RELEASE
SHEET NAME
SHEET NUMBER
PV-7
PROJECT NAME
SHEET SIZE
ANSI B
11" X 17"
SU
Z
A
N
N
E
M
C
C
O
Y
11
1
W
O
A
K
C
R
E
S
T
A
V
E
,
PO
R
T
A
N
G
E
L
E
S
,
WA
9
8
3
6
2
,
U
S
A
AP
N
#
06
3
0
1
6
5
3
0
0
1
0
0
0
0
0
UT
I
L
I
T
Y
:
CI
T
Y
O
F
P
O
R
T
A
N
G
E
L
E
S
AH
J
:
CI
T
Y
O
F
P
O
R
T
A
N
G
E
L
E
S
PR
O
J
E
C
T
N
U
M
B
E
R
:
P-
0
0
9
0
3
5
9
SPEC SHEETS
REVDATEDESCRIPTION
VERSION
UR04/11/2023INITIAL RELEASE
SHEET NAME
SHEET NUMBER
PV-8
PROJECT NAME
SHEET SIZE
ANSI B
11" X 17"
SU
Z
A
N
N
E
M
C
C
O
Y
11
1
W
O
A
K
C
R
E
S
T
A
V
E
,
PO
R
T
A
N
G
E
L
E
S
,
WA
9
8
3
6
2
,
U
S
A
AP
N
#
06
3
0
1
6
5
3
0
0
1
0
0
0
0
0
UT
I
L
I
T
Y
:
CI
T
Y
O
F
P
O
R
T
A
N
G
E
L
E
S
AH
J
:
CI
T
Y
O
F
P
O
R
T
A
N
G
E
L
E
S
PR
O
J
E
C
T
N
U
M
B
E
R
:
P-
0
0
9
0
3
5
9
SPEC SHEETS
REVDATEDESCRIPTION
VERSION
UR04/11/2023INITIAL RELEASE
SHEET NAME
SHEET NUMBER
PV-9
PROJECT NAME
SHEET SIZE
ANSI B
11" X 17"
SU
Z
A
N
N
E
M
C
C
O
Y
11
1
W
O
A
K
C
R
E
S
T
A
V
E
,
PO
R
T
A
N
G
E
L
E
S
,
WA
9
8
3
6
2
,
U
S
A
AP
N
#
06
3
0
1
6
5
3
0
0
1
0
0
0
0
0
UT
I
L
I
T
Y
:
CI
T
Y
O
F
P
O
R
T
A
N
G
E
L
E
S
AH
J
:
CI
T
Y
O
F
P
O
R
T
A
N
G
E
L
E
S
PR
O
J
E
C
T
N
U
M
B
E
R
:
P-
0
0
9
0
3
5
9
SPEC SHEETS
REVDATEDESCRIPTION
VERSION
UR04/11/2023INITIAL RELEASE
SHEET NAME
SHEET NUMBER
PV-10
PROJECT NAME
SHEET SIZE
ANSI B
11" X 17"
SU
Z
A
N
N
E
M
C
C
O
Y
11
1
W
O
A
K
C
R
E
S
T
A
V
E
,
PO
R
T
A
N
G
E
L
E
S
,
WA
9
8
3
6
2
,
U
S
A
AP
N
#
06
3
0
1
6
5
3
0
0
1
0
0
0
0
0
UT
I
L
I
T
Y
:
CI
T
Y
O
F
P
O
R
T
A
N
G
E
L
E
S
AH
J
:
CI
T
Y
O
F
P
O
R
T
A
N
G
E
L
E
S
PR
O
J
E
C
T
N
U
M
B
E
R
:
P-
0
0
9
0
3
5
9
SPEC SHEETS
REVDATEDESCRIPTION
VERSION
UR04/11/2023INITIAL RELEASE
SHEET NAME
SHEET NUMBER
PV-11
PROJECT NAME
SHEET SIZE
ANSI B
11" X 17"
SU
Z
A
N
N
E
M
C
C
O
Y
11
1
W
O
A
K
C
R
E
S
T
A
V
E
,
PO
R
T
A
N
G
E
L
E
S
,
WA
9
8
3
6
2
,
U
S
A
AP
N
#
06
3
0
1
6
5
3
0
0
1
0
0
0
0
0
UT
I
L
I
T
Y
:
CI
T
Y
O
F
P
O
R
T
A
N
G
E
L
E
S
AH
J
:
CI
T
Y
O
F
P
O
R
T
A
N
G
E
L
E
S
PR
O
J
E
C
T
N
U
M
B
E
R
:
P-
0
0
9
0
3
5
9
SPEC SHEETS
REVDATEDESCRIPTION
VERSION
UR04/11/2023INITIAL RELEASE
SHEET NAME
SHEET NUMBER
PV-12
PROJECT NAME
SHEET SIZE
ANSI B
11" X 17"
SU
Z
A
N
N
E
M
C
C
O
Y
11
1
W
O
A
K
C
R
E
S
T
A
V
E
,
PO
R
T
A
N
G
E
L
E
S
,
WA
9
8
3
6
2
,
U
S
A
AP
N
#
06
3
0
1
6
5
3
0
0
1
0
0
0
0
0
UT
I
L
I
T
Y
:
CI
T
Y
O
F
P
O
R
T
A
N
G
E
L
E
S
AH
J
:
CI
T
Y
O
F
P
O
R
T
A
N
G
E
L
E
S
PR
O
J
E
C
T
N
U
M
B
E
R
:
P-
0
0
9
0
3
5
9
SPEC SHEETS
REVDATEDESCRIPTION
VERSION
UR04/11/2023INITIAL RELEASE
SHEET NAME
SHEET NUMBER
PV-13
PROJECT NAME
SHEET SIZE
ANSI B
11" X 17"
SU
Z
A
N
N
E
M
C
C
O
Y
11
1
W
O
A
K
C
R
E
S
T
A
V
E
,
PO
R
T
A
N
G
E
L
E
S
,
WA
9
8
3
6
2
,
U
S
A
AP
N
#
06
3
0
1
6
5
3
0
0
1
0
0
0
0
0
UT
I
L
I
T
Y
:
CI
T
Y
O
F
P
O
R
T
A
N
G
E
L
E
S
AH
J
:
CI
T
Y
O
F
P
O
R
T
A
N
G
E
L
E
S
PR
O
J
E
C
T
N
U
M
B
E
R
:
P-
0
0
9
0
3
5
9
SPEC SHEETS
REVDATEDESCRIPTION
VERSION
UR04/11/2023INITIAL RELEASE
SHEET NAME
SHEET NUMBER
PV-14
PROJECT NAME
SHEET SIZE
ANSI B
11" X 17"
SU
Z
A
N
N
E
M
C
C
O
Y
11
1
W
O
A
K
C
R
E
S
T
A
V
E
,
PO
R
T
A
N
G
E
L
E
S
,
WA
9
8
3
6
2
,
U
S
A
AP
N
#
06
3
0
1
6
5
3
0
0
1
0
0
0
0
0
UT
I
L
I
T
Y
:
CI
T
Y
O
F
P
O
R
T
A
N
G
E
L
E
S
AH
J
:
CI
T
Y
O
F
P
O
R
T
A
N
G
E
L
E
S
PR
O
J
E
C
T
N
U
M
B
E
R
:
P-
0
0
9
0
3
5
9
SPEC SHEETS
REVDATEDESCRIPTION
VERSION
UR04/11/2023INITIAL RELEASE
SHEET NAME
SHEET NUMBER
PV-15
PROJECT NAME
SHEET SIZE
ANSI B
11" X 17"
SU
Z
A
N
N
E
M
C
C
O
Y
11
1
W
O
A
K
C
R
E
S
T
A
V
E
,
PO
R
T
A
N
G
E
L
E
S
,
WA
9
8
3
6
2
,
U
S
A
AP
N
#
06
3
0
1
6
5
3
0
0
1
0
0
0
0
0
UT
I
L
I
T
Y
:
CI
T
Y
O
F
P
O
R
T
A
N
G
E
L
E
S
AH
J
:
CI
T
Y
O
F
P
O
R
T
A
N
G
E
L
E
S
PR
O
J
E
C
T
N
U
M
B
E
R
:
P-
0
0
9
0
3
5
9
SPEC SHEETS
REVDATEDESCRIPTION
VERSION
UR04/11/2023INITIAL RELEASE
SHEET NAME
SHEET NUMBER
PV-16
PROJECT NAME
SHEET SIZE
ANSI B
11" X 17"
SU
Z
A
N
N
E
M
C
C
O
Y
11
1
W
O
A
K
C
R
E
S
T
A
V
E
,
PO
R
T
A
N
G
E
L
E
S
,
WA
9
8
3
6
2
,
U
S
A
AP
N
#
06
3
0
1
6
5
3
0
0
1
0
0
0
0
0
UT
I
L
I
T
Y
:
CI
T
Y
O
F
P
O
R
T
A
N
G
E
L
E
S
AH
J
:
CI
T
Y
O
F
P
O
R
T
A
N
G
E
L
E
S
PR
O
J
E
C
T
N
U
M
B
E
R
:
P-
0
0
9
0
3
5
9
SPEC SHEETS
REVDATEDESCRIPTION
VERSION
UR04/11/2023INITIAL RELEASE
SHEET NAME
SHEET NUMBER
PV-17
PROJECT NAME
SHEET SIZE
ANSI B
11" X 17"
SU
Z
A
N
N
E
M
C
C
O
Y
11
1
W
O
A
K
C
R
E
S
T
A
V
E
,
PO
R
T
A
N
G
E
L
E
S
,
WA
9
8
3
6
2
,
U
S
A
AP
N
#
06
3
0
1
6
5
3
0
0
1
0
0
0
0
0
UT
I
L
I
T
Y
:
CI
T
Y
O
F
P
O
R
T
A
N
G
E
L
E
S
AH
J
:
CI
T
Y
O
F
P
O
R
T
A
N
G
E
L
E
S
PR
O
J
E
C
T
N
U
M
B
E
R
:
P-
0
0
9
0
3
5
9
SPEC SHEETS
COVER SHEET
PHOTOVOLTAIC ROOF MOUNT SYSTEM
111 W OAKCREST AVE, PORT ANGELES, WA 98362, USA
REVDATEDESCRIPTION
VERSION
UR04/11/2023INITIAL RELEASE
SHEET NAME
SHEET NUMBER
PV-0
PROJECT NAME
SHEET SIZE
ANSI B
11" X 17"
SU
Z
A
N
N
E
M
C
C
O
Y
11
1
W
O
A
K
C
R
E
S
T
A
V
E
,
PO
R
T
A
N
G
E
L
E
S
,
WA
9
8
3
6
2
,
U
S
A
AP
N
#
06
3
0
1
6
5
3
0
0
1
0
0
0
0
0
UT
I
L
I
T
Y
:
CI
T
Y
O
F
P
O
R
T
A
N
G
E
L
E
S
AH
J
:
CI
T
Y
O
F
P
O
R
T
A
N
G
E
L
E
S
PR
O
J
E
C
T
N
U
M
B
E
R
:
P-
0
0
9
0
3
5
9
14/12/2023LAYOUT CHANGE A
08 MODULES-ROOF MOUNTED - 3.200 kWDC, 2.320 kWAC
GOVERNING CODES:
2020 NATIONAL ELECTRICAL CODE (NEC)
2018 INTERNATIONAL BUILDING CODE
2018 INTERNATIONAL EXISTING BUILDING CODE
2018 INTERNATIONAL SWIMMING POOL AND SPA CODE
2018 INTERNATIONAL FIRE CODE
2018 WASHINGTON STATE ENERGY CODE
2018 INTERNATIONAL RESIDENTIAL CODE
2018 INTERNATIONAL MECHANICAL CODE
2018 UNIFORM PLUMBING CODE
2 VICINITY MAP
SCALE: NTSPV-0
1 AERIAL PHOTO
SCALE: NTSPV-0
SHEET INDEX
PV-0 COVER SHEET
PV-1 SITE PLAN WITH ROOF PLAN
PV-2 ROOF PLAN WITH MODULES
PV-3 ATTACHMENT DETAILS
PV-4 ELECTRICAL LINE DIAGRAM WITH
CALCULATION
PV-5 WARNING LABELS & PLACARD
PV-6 SAFETY PLAN
PV-7+EQUIPMENT SPEC SHEETS
NOTES:
1.PHOTOVOLTAIC SYSTEM EQUIPMENT SHALL BE INSTALLED IN
ACCORDANCE WITH NEC 2020 ARTICLES 690 AND 705, AND THE 2018
IRC/IBC & 2018 INTERNATIONAL FIRE CODE, AND APPLICABLE
REQUIREMENTS OF THE SERVICE UTILITY AND AUTHORITY HAVING
JURISDICTION. PHOTOVOLTAIC SYSTEM EQUIPMENT WILL BE POSTED
WITH APPLICABLE WARNINGS, SIGNAGE AND PLAQUES PER NEC 690.13,
705.10 AND 706.15.
2.PHOTOVOLTAIC SOURCE AND OUTPUT CIRCUITS SHALL COMPLY WITH
THE WIRING METHODS AND INSTALLATION AND MARKING
REQUIREMENTS OF NEC 690.31(D).
3.BREAKER LABELED "PHOTOVOLTAIC ELECTRIC POWER SOURCE" AND
"BREAKERS ARE BACK FED" PER NEC 705.12(D) & NEC 690.59. BREAKER
ALSO LABELED "MAXIMUM AC OUTPUT CURRENT AND OPERATING AC
VOLTAGE" PER NEC 690.54. BREAKER SHALL BE POSITIONED AT THE
OPPOSITE (LOAD) END FROM THE INPUT FEEDER OR MAIN CIRCUIT
BREAKER LOCATION, AND LABELED "WARNING INVERTER OUTPUT
CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE", PER
NEC 705.12 (B)(3)(2).
4.WARNING SIGN PER NEC 706.15(C)(4) and NEC 690.13(B) READING
"WARNING - ELECTRIC SHOCK HAZARD - TERMINALS ON BOTH LINE AND
LOAD SIDES MAY BE ENERGIZED IN THE OFF POSITION."
5.LABEL "PHOTOVOLTAIC SYSTEM UTILITY DISCONNECT SWITCH." SWITCH
TO BE LOCKED PER NEC 690.13(B). SWITCH TO BE VISIBLE BLADE
DISCONNECT PER UTILITY REQUIREMENTS AND CONFORM TO NEC
705.22.
6.LABEL "PHOTOVOLTAIC ARRAY DC DISCONNECT SWITCH" PER NEC
690.13(B). LABEL WITH OPERATING CURRENT, OPERATING VOLTAGE,
MAXIMUM SYSTEM VOLTAGE, AND SHORT CIRCUIT CURRENT PER NEC
690.53. SWITCH LOCKED PER NEC 690.13(B).
7.LISTING AGENCY NAMES AND NUMBERS TO BE INDICATED ON POWER
INVERTER(S) AND SOLAR MODULES PER NEC 110.3 (B).
8.LABELED PHOTOVOLTAIC SYSTEM DEDICATED KWH METER. (NOT USED)
9.BI-DIRECTIONAL METER TO BE INSTALLED BY UTILITY.
10.DEDICATED PHOTOVOLTAIC COMBINER SUB-PANEL. LABEL "LOADS NOT
TO BE ADDED TO THIS PANEL."
11.ALL LABELS EXPOSED TO SUNLIGHT MUST BE ENGRAVED AND
ATTACHED PER APPROVED METHOD.
12.LABEL "BREAKER HAS BEEN DE-RATED PER NEC 705.12(D)(2)." NO NEW
LOADS.
13.EXISTING EQUIPMENT IS NOTED WITH A DASHED LINE. SOLID LINES
DENOTE EQUIPMENT INSTALLED BY ELECTRICAL CONTRACTOR.
14.WIRE MAY BE RUN SHORT DISTANCES OUTSIDE OF CONDUIT IF WIRE
READS "SUNLIGHT RESISTANT."
15.THE GROUNDING ELECTRODE CONDUCTOR SHALL BE CONTINUOUS AND
TERMINATE WITH AN IRREVERSIBLE CONNECTION TO THE AC
GROUNDING ELECTRODE SYSTEM PER NEC 250.64(B).
16.AMBIENT TEMPERATURE ADJUSTED FOR CONDUITS EXPOSED TO
SUNLIGHT ON OR ABOVE ROOFTOPS PER TABLE 310.15 (B)(2). CONDUIT
ELEVATED MIN. 1/2"; ADDER 33 DEG F.
17.ALL EXTERIOR EQUIPMENT TO BE NEMA 3R.
18.THE PHOTOVOLTAIC POWER SOURCE SHALL BE LABELED WITH THE
FOLLOWING WARNING AT EACH JUNCTION BOX, COMBINER BOX,
DISCONNECT AND DEVICE WHERE ENERGIZED, UNGROUNDED CIRCUITS
MAY BE EXPOSED DURING SERVICE:
WARNING: ELECTRIC SHOCK HAZARD. THE DC CONDUCTORS OF THIS
PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED
SYSTEM SUMMARY:
(N) 08 - HANWHA Q CELLS Q.PEAK DUO BLK ML-G10+ / t (400W) MODULES
(N) 08 - ENPHASE ENERGY IQ8PLUS-72-2-US MICRO-INVERTERS [240V]
(N) JUNCTION BOX
(E) 200A MAIN SERVICE PANEL WITH (E) 200A MAIN BREAKER
(N) ENPHASE IQ COMBINER 4 [240V]
X2-IQ-AM1-240-4 (IEEE 1547:2018)
(N) 60A FUSED AC DISCONNECT [240V]
ROOF TYPE: - ASPHALT SHINGLES
NUMBER OF LAYERS: - 01
ROOF FRAME: - 2"X6" TRUSSES @ 24" O.C.
STORY: - ONE STORY
SNOW LOAD : - 25 PSF
WIND SPEED :- 110 MPH
WIND EXPOSURE:- C
RISK CATEGORY:- II
COORDINATE:- 48.099718, -123.446284
DESIGN CRITERIA:
UTILITY METER NO: 28 356 811
20-DEC-2023
EXP.:15-DEC-2025
STRUCTURAL ONLY
AC
D
MS
P
UM
JB
CB
~89.68'
~9
5
.
1
6
'
~9
5
.
1
6
'
~89.68'
15'-2"
31
'
-
0
"
15
'
-
1
1
"
17'-5"
AC
D
MS
P
UM
JB
CB
SITE PLAN WITH ROOF PLAN
REVDATEDESCRIPTION
VERSION
UR04/11/2023INITIAL RELEASE
SHEET NAME
SHEET NUMBER
PV-1
PROJECT NAME
SHEET SIZE
ANSI B
11" X 17"
SU
Z
A
N
N
E
M
C
C
O
Y
11
1
W
O
A
K
C
R
E
S
T
A
V
E
,
PO
R
T
A
N
G
E
L
E
S
,
WA
9
8
3
6
2
,
U
S
A
AP
N
#
06
3
0
1
6
5
3
0
0
1
0
0
0
0
0
UT
I
L
I
T
Y
:
CI
T
Y
O
F
P
O
R
T
A
N
G
E
L
E
S
AH
J
:
CI
T
Y
O
F
P
O
R
T
A
N
G
E
L
E
S
PR
O
J
E
C
T
N
U
M
B
E
R
:
P-
0
0
9
0
3
5
9
14/12/2023LAYOUT CHANGE A
SITE PLAN WITH
ROOF PLAN
1 SCALE: 1/16" = 1'-0"
ROOF ACCESS POINT SHALL BE LOCATED IN AREAS THAT DO NOT REQUIRE THE
PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS WINDOWS OR
DOORS, AND LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION IN
LOCATIONS WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD
OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES OR SIGNS.
NOTE: THE AC DISCONNECT IS LOCATED
WITHIN 10FT OF UTILITY METER
NOTE:
3/4" OR GREATER EMT CONDUIT
RUN (7/8" ABOVE ROOF SURFACE)
LEGEND
JUNCTION BOXJB
MSP MAIN SERVICE PANEL
GATE
FENCE
TREES
ENPHASE IQ COMBINER 4
X2-IQ-AM1-240-4 (IEEE 1547:2018)CB
UTILITY METERUM
VENT, ATTIC FAN (ROOF OBSTRUCTION)
PROPERTY LINE
AC DISCONNECTACD
W OAKCREST AVE
ONE- STORY
HOUSE
EXISTING
DRIVEWAY
(E) STRUCTURE
ROOF ACCESS POINT
A
20-DEC-2023
EXP.:15-DEC-2025
STRUCTURAL ONLY
AC
D
MS
P
UM
JB
CB
4'-5"18'-8"13'-2"
1'
-
3
"
8'
-
1
1
"
2'
-
6
"
REVDATEDESCRIPTION
VERSION
UR04/11/2023INITIAL RELEASE
SHEET NAME
SHEET NUMBER
PV-2
PROJECT NAME
SHEET SIZE
ANSI B
11" X 17"
SU
Z
A
N
N
E
M
C
C
O
Y
11
1
W
O
A
K
C
R
E
S
T
A
V
E
,
PO
R
T
A
N
G
E
L
E
S
,
WA
9
8
3
6
2
,
U
S
A
AP
N
#
06
3
0
1
6
5
3
0
0
1
0
0
0
0
0
UT
I
L
I
T
Y
:
CI
T
Y
O
F
P
O
R
T
A
N
G
E
L
E
S
AH
J
:
CI
T
Y
O
F
P
O
R
T
A
N
G
E
L
E
S
PR
O
J
E
C
T
N
U
M
B
E
R
:
P-
0
0
9
0
3
5
9
14/12/2023LAYOUT CHANGE A
ROOF PLAN WITH
MODULES
ROOF PLAN WITH MODULES
SCALE: 1/8" = 1'-0"1
MODULE TYPE, DIMENSIONS & WEIGHT
NUMBER OF MODULES = 08 MODULES
MODULE TYPE = HANWHA Q CELLS Q.PEAK DUO BLK ML-G10+ / t
(400W) MODULES
MODULE WEIGHT = 48.5 LBS / 22.0 KG.
MODULE DIMENSIONS = 74.0"X 41.1" = 21.12 SF
UNIT WEIGHT OF ARRAY = 2.30 PSF
NOTE: ACTUAL ROOF CONDITIONS AND
TRUSSES LOCATIONS MAY VARY. INSTALL
PER MANUFACTURER(S) INSTALLATION
GUIDELINES AND ENGINEERED SPANS FOR
ATTACHMENTS
· PLUMBING VENTS, SKYLIGHTS AND MECHANICAL VENTS SHALL
NOT BE COVERED, MOVED, RE-ROUTED OR RE-LOCATED.
NOTE: THE AC DISCONNECT IS LOCATED
WITHIN 10FT OF UTILITY METER
NOTE:
3/4" OR GREATER EMT CONDUIT
RUN (7/8" ABOVE ROOF SURFACE)
ARRAY AREA & ROOF AREA CALC'S
AREA OF NEW ARRAY
(Sq. Ft.)
AREA OF ROOF(PLAN
VIEW)
(Sq. Ft.)
TOTAL ROOF AREA
COVERED BY ARRAY %
168.97 2184.72 7.73%
ARRAY AREA & ROOF AREA CALC'S
ROOF # OF
MODULES
ARRAY
AREA
(Sq. Ft.)
ROOF
AREA
(Sq. Ft.)
ROOF
AREA
COVERED BY
ARRAY (%)
#1 08 168.97 380.05 44.46
ROOF DESCRIPTION
ROOF TYPE ASPHALT SHINGLES
ROOF
ROOF ROOF
TILT AZIMUTH TRUSSES
SIZE
TRUSSES
SPACING
#1 23°181°2"x6"24" O.C.
LEGEND
VENT, ATTIC FAN
(ROOF OBSTRUCTION)
ROOF ATTACHMENT UNIRAC STRONGHOLD
BUTYL @ 48", 72" O.C.
TRUSSES
JUNCTION BOXJB
MSP MAIN SERVICE PANEL
FIRE PATHWAY
UNIRAC NXT UMOUNT RAIL
ENPHASE ENERGY IQ8PLUS-72-2-US
MICRO-INVERTERS
ENPHASE IQ COMBINER 4
X2-IQ-AM1-240-4 (IEEE 1547:2018)CB
UTILITY METERUM
AC DISCONNECTACD
BILL OF MATERIALS
EQUIPMENT QTY DESCRIPTION
RAIL 06 UNIRAC NXT UMOUNT RAIL 168" DRK
RAIL SPLICE 4 NXT UMOUNT RAIL SPLICE
UNIVERSAL CLAMP 20 NXT UMOUNT COMBO CLAMP DRK
ROOF
ATTACHMENTS 20 UNIRAC STRONGHOLD BUTYL
ACCESSORIES 8 NXT UMOUNT RL & CLMP CAP KIT
MLPE & GROUNDING 10 NXT UMOUNT MLPE & LUG CLAMP
W OAKCREST AVE
FRONT YARD
REAR YARD
18" FIRE PATHWAY
18" FIRE PATHWAY
1
8
"
F
I
R
E
P
A
T
H
W
A
Y
1
8
"
F
I
R
E
P
A
T
H
W
A
Y
36
"
F
I
R
E
P
A
T
H
W
A
Y
ROOF #1
A
A
20-DEC-2023
EXP.:15-DEC-2025
STRUCTURAL ONLY
PV RACKING DESIGNED BY OTHER
REVDATEDESCRIPTION
VERSION
UR04/11/2023INITIAL RELEASE
SHEET NAME
SHEET NUMBER
PV-3
PROJECT NAME
SHEET SIZE
ANSI B
11" X 17"
SU
Z
A
N
N
E
M
C
C
O
Y
11
1
W
O
A
K
C
R
E
S
T
A
V
E
,
PO
R
T
A
N
G
E
L
E
S
,
WA
9
8
3
6
2
,
U
S
A
AP
N
#
06
3
0
1
6
5
3
0
0
1
0
0
0
0
0
UT
I
L
I
T
Y
:
CI
T
Y
O
F
P
O
R
T
A
N
G
E
L
E
S
AH
J
:
CI
T
Y
O
F
P
O
R
T
A
N
G
E
L
E
S
PR
O
J
E
C
T
N
U
M
B
E
R
:
P-
0
0
9
0
3
5
9
14/12/2023LAYOUT CHANGE A
ATTACHMENT
DETAIL
ATTACHMENT DETAIL
SCALE: NTS1
ATTACHMENT DETAIL (ENLARGED VIEW)
SCALE: NTS2
NOTE: ACTUAL ROOF CONDITIONS AND TRUSSES (OR SEAM)
LOCATIONS MAY VARY. INSTALL PER MANUFACTURER(S)
INSTALLATION GUIDELINES AND ENGINEERED SPANS FOR
ATTACHMENTS
(E) 2"X6"
TRUSS
E
S
@ 24" O.CENLARGE VIEW
(N) PV MODULES
(E) ASPHALT SHINGLES ROOF
(N) NXT UMOUNT COMBO CLAMP
(N) PV MODULES
(N) NXT UMOUNT RAIL
(N) NXT UMOUNT RAIL CLAMP ASSY
(E) ROOF / DECK MEMBRANE
(E) ASPHALT SHINGLES ROOF
5/16"-18 x 2"
SERRATED FLANGE HEX SCREW
~4
"
~
4
"
1-3/4" MIN.
EMBEDMENT
1
.
2
6
"
1.
2
6
"
(N) DTD BUTYL ATT ASSY (1/8" BUTYL)
2X12-14 SCREW, HWH, SS, SELF-DR
W/ #12 EPDM WASHER
(N) STRONGHOLD BUTYL ATTACHMENTS, DRK
20-DEC-2023
EXP.:15-DEC-2025
STRUCTURAL ONLY
REVDATEDESCRIPTION
VERSION
UR04/11/2023INITIAL RELEASE
SHEET NAME
SHEET NUMBER
PV-4
PROJECT NAME
SHEET SIZE
ANSI B
11" X 17"
SU
Z
A
N
N
E
M
C
C
O
Y
11
1
W
O
A
K
C
R
E
S
T
A
V
E
,
PO
R
T
A
N
G
E
L
E
S
,
WA
9
8
3
6
2
,
U
S
A
AP
N
#
06
3
0
1
6
5
3
0
0
1
0
0
0
0
0
UT
I
L
I
T
Y
:
CI
T
Y
O
F
P
O
R
T
A
N
G
E
L
E
S
AH
J
:
CI
T
Y
O
F
P
O
R
T
A
N
G
E
L
E
S
PR
O
J
E
C
T
N
U
M
B
E
R
:
P-
0
0
9
0
3
5
9
14/12/2023LAYOUT CHANGE A
ELECTRICAL LINE
DIAGRAM &
CALCULATION
ELECTRICAL LINE DIAGRAM WITH CALCULATION
SCALE: NTS1
L
200A
(E) MAIN BREAKER
200A/2P, 240V
(E) MAIN
SERVICE PANEL,
200A RATED,
120/240V
EXISTING
GROUNDING
SYSTEM
BI-DIRECTIONAL
UTILITY METER
1-PHASE, 3-W,
120V/240V, 60Hz
(N) 60A FUSED AC
DISCONNECT, WITH 20A
FUSES,
240 VAC
G
N N
L2
L1
L2
L1
20A FUSES
AC DISCONNECT SHALL BE
LOCATED WITHIN 10' OF
UTILITY METER
LINE SIDE
CONNECTION
NOTE-TAP CONDUCTORS SHALL BE 10' OR
LESS PER NEC 705.31
C
NOTE: THE AC DISCONNECT IS LOCATED
WITHIN 10FT OF UTILITY METER
·GAS METER LOCATED IN PROXIMITY OF THE PV INSTALLATION, LOAD CENTER, AND/OR
DISCONNECTS. DISCONNECTS SHALL BE LOCATED IN COMPLIANCE WITH UTILITY AND THE AHJ
(AUTHORITY HAVING JURISDICTION). PV INSTALLATION SHALL COMPLY WITH ALL APPLICABLE
CODES.
·WIRE RATED AND AMPACITY CALCULATED @ 90°C FOR ROOFTOP INSTALLATION AND ATTIC RUN
TO INVERTER.
·PER NEC REQUIRMENTS GROUNDING CONDUCTORS SMALLER THAN 6AWG SHALL BE
PROTECTED IN A CONDUIT, RACEWAY, OR ARMORED PROTECTIVE SHEATHING (NEC 250.64).
·THE WORKING CLEARANCES AROUND THE EXISTING ELECTRICAL EQUIPMENT AS WELL AS THE
NEW ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN ACCORDANCE WITH NEC 110.26.
·ANY CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT. (NEC
300.6 C1, 310.8 D).
·ROOM FOR EQUIPMENT WITHIN 5 FEET FROM MSP.
·ALL CONDUIT SHALL BE EMT 3/4" IN DIAMETER UNLESS OTHERWISE STATED.
·CONFIGURE FOR IEEE 1547 ANTI-ISLANDING GRID PROFILE.
UTILITY PROVIDER:
MAIN SERVICE VOLTAGE:
MAIN PANEL BRAND:
MAIN SERVICE PANEL:
MAIN CIRCUIT BREAKER RATING:
MAIN SERVICE LOCATION:
SERVICE FEED SOURCE:
CITY OF PORT ANGELES
240V
CUTLER-HAMMER
(E) 200A
(E) 200A
WEST
SERVICE INFO.
OVERHEAD
NOTE:
3/4" OR GREATER EMT CONDUIT
RUN (7/8" ABOVE ROOF SURFACE)
SYSTEM SIZE:- 08 x 400W = 3.200 kWDC
08 x 290VA = 2.320 kWAC
INVERTER SPECIFICATIONS
MANUFACTURER / MODEL #QUANTITY NOMINAL OUTPUT
VOLTAGE
NOMINAL OUTPUT
CURRENT
ENPHASE ENERGY
IQ8PLUS-72-2-US 08 240 VAC 1.21A
(08) ENPHASE ENERGY
IQ8PLUS-72-2-US
MICRO-INVERTERS (240V)
(LOCATED UNDER EACH PANEL)
(N) JUNCTION BOX
G
N
G
TERMINATOR CAP ON LAST CABLE
CONNECTOR Q- CABLE (TYP)
10A/15A
M*IQ-GATEWAY
20A
08 MICRO-INVERTERS IN BRANCH #1
L1L1
L2L2
(N) ENPHASE IQ
COMBINER BOX 4
X2-IQ-AM1-240-4
(IEEE1547:2018) [240V]
A B
AMBIENT TEMPERATURE SPECIFICATIONS
RECORD
LOW TEMP
AMBIENT TEMP
(HIGH TEMP 2%)
CONDUCTOR
TEMPERATURE
RATE
-6°25°90°
NOTE-EQUIPMENT RATED AT 75 DEGREES
Wire Tag Conduit Wire Qty Wire
Gauge Wire Type Temp.
Rating
Wire
Ampacity (A)
Temp.
Derate
Conduit
Fill Derate
Derated
Ampacity (A)
Inverter
Qty NOC (A)NEC
Correction
Design
Current (A)
Ground
Size
Ground Wire
Type
A OPEN AIR 1 12 AWG Q Cable 90°C 30 1.04 N/A 31.20 08 1.21 1.25 12.10 06 AWG BARE CU
B 3/4" EMT 2 12 AWG THWN-2 90°C 30 1.04 1.0 31.20 08 1.21 1.25 12.10 06 AWG THWN-2
C 3/4" EMT 3 6 AWG THWN-2 90°C 75 1.04 1.0 78.00 08 1.21 1.25 12.10 06 AWG THWN-2
D 3/4" PVC 3 6 AWG THWN-2 90°C 75 1.04 1.0 78.00 08 1.21 1.25 12.10 06 AWG THWN-2
UTILITY METER NO: 28 356 811
SOLAR MODULE SPECIFICATIONS
MANUFACTURER / MODEL #VMP
(V)
IMP
(A)
VOC
(V)
ISC
(A)
TEMPERATURE
COEFFICIENT
OF Voc
# OF
MODULES
HANWHA Q CELLS Q.PEAK DUO
BLK ML-G10+ / t (400W)38.09 10.50 45.55 11.07 -0.27%/K 08
MODULE DIMENSION 74.0" L x 41.1" W x 1.26" D
D
CONSUMPTION CT's
REVDATEDESCRIPTION
VERSION
UR04/11/2023INITIAL RELEASE
SHEET NAME
SHEET NUMBER
PV-5
PROJECT NAME
SHEET SIZE
ANSI B
11" X 17"
SU
Z
A
N
N
E
M
C
C
O
Y
11
1
W
O
A
K
C
R
E
S
T
A
V
E
,
PO
R
T
A
N
G
E
L
E
S
,
WA
9
8
3
6
2
,
U
S
A
AP
N
#
06
3
0
1
6
5
3
0
0
1
0
0
0
0
0
UT
I
L
I
T
Y
:
CI
T
Y
O
F
P
O
R
T
A
N
G
E
L
E
S
AH
J
:
CI
T
Y
O
F
P
O
R
T
A
N
G
E
L
E
S
PR
O
J
E
C
T
N
U
M
B
E
R
:
P-
0
0
9
0
3
5
9
14/12/2023LAYOUT CHANGE A
WARNING LABELS &
PLACARD
POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE
FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN
11
1
W
O
A
K
C
R
E
S
T
A
V
E
(E) 200A MAIN SERVICE PANEL
WITH (E) 200A MAIN BREAKER
(E) UTILITY METER
(N) 60A FUSED AC DISCONNECT
(N) ENPHASE IQ COMBINER BOX 4
(N) PV MODULES
CAUTION !
MULTIPLE SOURCES OF POWER
WARNING DUAL POWER SOURCE
SECOND SOURCE IS PHOTOVOLTAIC SYSTEM
LABEL LOCATION:
EMT/CONDUIT RACEWAYS
(PER CODE: NEC690.31(D)(2)
PHOTOVOLTAIC POWER SOURCE
LABEL LOCATION:
POINT OF INTERCONNECTION
PRODUCTION METER
NEC 705.12(D)(3) & NEC 690.59)
NOTES AND SPECIFICATIONS:
·SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE
2020 ARTICLE 110.21(B), UNLESS SPECIFIC INSTRUCTIONS
ARE REQUIRED BY SECTION 690, OR IF REQUESTED BY THE
LOCAL AHJ.
·SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS
USING EFFECTIVE WORDS, COLORS AND SYMBOLS.
·LABELS SHALL BE PERMANENTLY AFFIXED TO THE
EQUIPMENT OR WIRING METHOD AND SHALL NOT BE HAND
WRITTEN.
·LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND
THE ENVIRONMENT INVOLVED.
·SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011,
PRODUCT SAFETY SIGNS AND LABELS, UNLESS OTHERWISE
SPECIFIED.
·DO NOT COVER EXISTING MANUFACTURER LABELS.
ELECTRICAL SHOCK HAZARD
WARNING
TERMINALS ON LINE AND LOAD
SIDES MAY BE ENERGIZED IN
THE OPEN POSITION
LABEL LOCATION:
INVERTER(S), AC DISCONNECT(S), AC
COMBINER PANEL (IF APPLICABLE).
PER CODE(S): NEC 2020: NEC 690.13(B)
& NEC 690.15(C)
MAXIMUM AC OPERATING CURRENT:
NOMINAL OPERATING AC VOLTAGE:
9.68 AMPS
240 VAC
LABEL LOCATION:
AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF
INTERCONNECTION.
PER CODE(S): NEC 2020: 690.54
SOLAR PV SYSTEM EQUIPPED
WITH RAPID SHUTDOWN
SOLAR ELECTRIC
PV PANELS
TURN RAPID SHUTDOWN
SWITCH TO THE "OFF"
POSITION TO SHUT DOWN
PV SYSTEM AND REDUCE
SHOCK HAZARD IN THE
ARRAY.
!
3"
3"
PHOTOVOLTAIC SYSTEM AC DISCONNECT
MAIN PHOTOVOLTAIC
SYSTEM DISCONNECT
LABEL LOCATION:
MAIN SERVICE DISCONNECT / UTILITY METER
(PER CODE: NEC 690.13(B))
RAPID SHUTDOWN SWITCH
FOR SOLAR PV SYSTEM
!
WARNING
THE DISCONNECTION OF THE
GROUNDED CONDUCTOR(S)
MAY RESULT IN OVERVOLTAGE
ON THE EQUIPMENT
!
LABEL LOCATION:
COMBINER BOX
PER CODE: NEC 690.31(E)
PHOTOVOLTAIC
AC DISCONNECT
LABEL LOCATION:
AC DISCONNECT
NEC 690.13(B)
LABEL LOCATION:
MAIN SERVICE PANEL
PER CODE(S): NEC 2020: IFC 605.11.3.1(1) & 690.56(C)
LABEL LOCATION:
UTILITY SERVICE ENTRANCE/METER,
INVERTER/DC DISCONNECT IF REQUIRED BY
LOCAL AHJ, OR OTHER LOCATIONS (WITHIN 3 FT)
AS REQUIRED BY LOCAL AHJ.
PER CODE(S): NEC 2020: 690.56(C)(2)
A
REVDATEDESCRIPTION
VERSION
UR04/11/2023INITIAL RELEASE
SHEET NAME
SHEET NUMBER
PV-6
PROJECT NAME
SHEET SIZE
ANSI B
11" X 17"
SU
Z
A
N
N
E
M
C
C
O
Y
11
1
W
O
A
K
C
R
E
S
T
A
V
E
,
PO
R
T
A
N
G
E
L
E
S
,
WA
9
8
3
6
2
,
U
S
A
AP
N
#
06
3
0
1
6
5
3
0
0
1
0
0
0
0
0
UT
I
L
I
T
Y
:
CI
T
Y
O
F
P
O
R
T
A
N
G
E
L
E
S
AH
J
:
CI
T
Y
O
F
P
O
R
T
A
N
G
E
L
E
S
PR
O
J
E
C
T
N
U
M
B
E
R
:
P-
0
0
9
0
3
5
9
14/12/2023LAYOUT CHANGE A
SAFETY PLAN
SYSTEM SIZE:- 08 x 400W = 3.200 kWDC
08 x 290VA = 2.320 kWAC
SAFETY PLAN
SCALE: NTS1
INSPECT ENTIRE JOB SITE FOR HAZARDS
SAFETY PLAN CHECKLIST ABBR.
INDICATE PARKING LOCATION FOR COMPANY VEHICLES
SD
CV
INDICATE LOCATION OF SAFETY DOCUMENTS
FIRE EXTINGUISHER LOCATION FE
H
FIRST AID KIT LOCATION FA
EYE WASH LOCATION EW
DRINKING WATER LOCATION DW
IDENTIFY HARD HAT ZONE HHZ
DRAW FALL PROTECTION ANCHOR LOCATION X
DRAW LADDER & ROOF ACCESS LOCATION L
DRAW LADDER ANCHOR LOCATION LA
IDENTIFY ELECTRICAL HAZARD AREAS EH
INDICATE OTHER HAZARD LOCATION AND SPECIFY
(E.G. WATER,TRIPPING,ANIMALS,INSECTS,ETC.)
WEATHER FORECAST
HOURLY
HEAT INDEX HIPP MEASURES
7 AM
8 AM
9 AM
10 AM
11 AM
12 AM
1 AM
2 AM
3 AM
4 AM
5 AM
OTHER WEATHER RELATED HAZARDS & MEASURES
WET OR ICY SURFACES
HIGH WINDS
THUNDER STOMS
WILDFIRE SMOKE
OTHER
ADDRESS & PHONE NUMBER OF CLOSEST URGENT CARE FACILTY
CREW LEAD SIGNATURE & DATE(S)
CREW LEAD SIGNATURE & DATE(S)
NOTE: CREW LEAD MUST CONDUCT A DAILY MEETING TO REVIEW ALL SAFTEY ITEMS.
1
2
3
4
5
NOTE: FOR MULTIPLE DAY JOBS,SAFETY MEETINGS MUST BE CONDUCTED EACH DAY.
INDICATE BY INITIALING NEXT TO YOUR SIGNATURE FOR EACH ADDITIONAL DAY.
W OAKCREST AVE
A
REVDATEDESCRIPTION
VERSION
UR04/11/2023INITIAL RELEASE
SHEET NAME
SHEET NUMBER
PV-7
PROJECT NAME
SHEET SIZE
ANSI B
11" X 17"
SU
Z
A
N
N
E
M
C
C
O
Y
11
1
W
O
A
K
C
R
E
S
T
A
V
E
,
PO
R
T
A
N
G
E
L
E
S
,
WA
9
8
3
6
2
,
U
S
A
AP
N
#
06
3
0
1
6
5
3
0
0
1
0
0
0
0
0
UT
I
L
I
T
Y
:
CI
T
Y
O
F
P
O
R
T
A
N
G
E
L
E
S
AH
J
:
CI
T
Y
O
F
P
O
R
T
A
N
G
E
L
E
S
PR
O
J
E
C
T
N
U
M
B
E
R
:
P-
0
0
9
0
3
5
9
14/12/2023LAYOUT CHANGE A
SPEC SHEETS
REVDATEDESCRIPTION
VERSION
UR04/11/2023INITIAL RELEASE
SHEET NAME
SHEET NUMBER
PV-8
PROJECT NAME
SHEET SIZE
ANSI B
11" X 17"
SU
Z
A
N
N
E
M
C
C
O
Y
11
1
W
O
A
K
C
R
E
S
T
A
V
E
,
PO
R
T
A
N
G
E
L
E
S
,
WA
9
8
3
6
2
,
U
S
A
AP
N
#
06
3
0
1
6
5
3
0
0
1
0
0
0
0
0
UT
I
L
I
T
Y
:
CI
T
Y
O
F
P
O
R
T
A
N
G
E
L
E
S
AH
J
:
CI
T
Y
O
F
P
O
R
T
A
N
G
E
L
E
S
PR
O
J
E
C
T
N
U
M
B
E
R
:
P-
0
0
9
0
3
5
9
14/12/2023LAYOUT CHANGE A
SPEC SHEETS
REVDATEDESCRIPTION
VERSION
UR04/11/2023INITIAL RELEASE
SHEET NAME
SHEET NUMBER
PV-9
PROJECT NAME
SHEET SIZE
ANSI B
11" X 17"
SU
Z
A
N
N
E
M
C
C
O
Y
11
1
W
O
A
K
C
R
E
S
T
A
V
E
,
PO
R
T
A
N
G
E
L
E
S
,
WA
9
8
3
6
2
,
U
S
A
AP
N
#
06
3
0
1
6
5
3
0
0
1
0
0
0
0
0
UT
I
L
I
T
Y
:
CI
T
Y
O
F
P
O
R
T
A
N
G
E
L
E
S
AH
J
:
CI
T
Y
O
F
P
O
R
T
A
N
G
E
L
E
S
PR
O
J
E
C
T
N
U
M
B
E
R
:
P-
0
0
9
0
3
5
9
14/12/2023LAYOUT CHANGE A
SPEC SHEETS
REVDATEDESCRIPTION
VERSION
UR04/11/2023INITIAL RELEASE
SHEET NAME
SHEET NUMBER
PV-10
PROJECT NAME
SHEET SIZE
ANSI B
11" X 17"
SU
Z
A
N
N
E
M
C
C
O
Y
11
1
W
O
A
K
C
R
E
S
T
A
V
E
,
PO
R
T
A
N
G
E
L
E
S
,
WA
9
8
3
6
2
,
U
S
A
AP
N
#
06
3
0
1
6
5
3
0
0
1
0
0
0
0
0
UT
I
L
I
T
Y
:
CI
T
Y
O
F
P
O
R
T
A
N
G
E
L
E
S
AH
J
:
CI
T
Y
O
F
P
O
R
T
A
N
G
E
L
E
S
PR
O
J
E
C
T
N
U
M
B
E
R
:
P-
0
0
9
0
3
5
9
14/12/2023LAYOUT CHANGE A
SPEC SHEETS
REVDATEDESCRIPTION
VERSION
UR04/11/2023INITIAL RELEASE
SHEET NAME
SHEET NUMBER
PV-11
PROJECT NAME
SHEET SIZE
ANSI B
11" X 17"
SU
Z
A
N
N
E
M
C
C
O
Y
11
1
W
O
A
K
C
R
E
S
T
A
V
E
,
PO
R
T
A
N
G
E
L
E
S
,
WA
9
8
3
6
2
,
U
S
A
AP
N
#
06
3
0
1
6
5
3
0
0
1
0
0
0
0
0
UT
I
L
I
T
Y
:
CI
T
Y
O
F
P
O
R
T
A
N
G
E
L
E
S
AH
J
:
CI
T
Y
O
F
P
O
R
T
A
N
G
E
L
E
S
PR
O
J
E
C
T
N
U
M
B
E
R
:
P-
0
0
9
0
3
5
9
14/12/2023LAYOUT CHANGE A
SPEC SHEETS
REVDATEDESCRIPTION
VERSION
UR04/11/2023INITIAL RELEASE
SHEET NAME
SHEET NUMBER
PV-12
PROJECT NAME
SHEET SIZE
ANSI B
11" X 17"
SU
Z
A
N
N
E
M
C
C
O
Y
11
1
W
O
A
K
C
R
E
S
T
A
V
E
,
PO
R
T
A
N
G
E
L
E
S
,
WA
9
8
3
6
2
,
U
S
A
AP
N
#
06
3
0
1
6
5
3
0
0
1
0
0
0
0
0
UT
I
L
I
T
Y
:
CI
T
Y
O
F
P
O
R
T
A
N
G
E
L
E
S
AH
J
:
CI
T
Y
O
F
P
O
R
T
A
N
G
E
L
E
S
PR
O
J
E
C
T
N
U
M
B
E
R
:
P-
0
0
9
0
3
5
9
14/12/2023LAYOUT CHANGE A
SPEC SHEETS
REVDATEDESCRIPTION
VERSION
UR04/11/2023INITIAL RELEASE
SHEET NAME
SHEET NUMBER
PV-13
PROJECT NAME
SHEET SIZE
ANSI B
11" X 17"
SU
Z
A
N
N
E
M
C
C
O
Y
11
1
W
O
A
K
C
R
E
S
T
A
V
E
,
PO
R
T
A
N
G
E
L
E
S
,
WA
9
8
3
6
2
,
U
S
A
AP
N
#
06
3
0
1
6
5
3
0
0
1
0
0
0
0
0
UT
I
L
I
T
Y
:
CI
T
Y
O
F
P
O
R
T
A
N
G
E
L
E
S
AH
J
:
CI
T
Y
O
F
P
O
R
T
A
N
G
E
L
E
S
PR
O
J
E
C
T
N
U
M
B
E
R
:
P-
0
0
9
0
3
5
9
14/12/2023LAYOUT CHANGE A
SPEC SHEETS
REVDATEDESCRIPTION
VERSION
UR04/11/2023INITIAL RELEASE
SHEET NAME
SHEET NUMBER
PV-14
PROJECT NAME
SHEET SIZE
ANSI B
11" X 17"
SU
Z
A
N
N
E
M
C
C
O
Y
11
1
W
O
A
K
C
R
E
S
T
A
V
E
,
PO
R
T
A
N
G
E
L
E
S
,
WA
9
8
3
6
2
,
U
S
A
AP
N
#
06
3
0
1
6
5
3
0
0
1
0
0
0
0
0
UT
I
L
I
T
Y
:
CI
T
Y
O
F
P
O
R
T
A
N
G
E
L
E
S
AH
J
:
CI
T
Y
O
F
P
O
R
T
A
N
G
E
L
E
S
PR
O
J
E
C
T
N
U
M
B
E
R
:
P-
0
0
9
0
3
5
9
14/12/2023LAYOUT CHANGE A
SPEC SHEETS
REVDATEDESCRIPTION
VERSION
UR04/11/2023INITIAL RELEASE
SHEET NAME
SHEET NUMBER
PV-15
PROJECT NAME
SHEET SIZE
ANSI B
11" X 17"
SU
Z
A
N
N
E
M
C
C
O
Y
11
1
W
O
A
K
C
R
E
S
T
A
V
E
,
PO
R
T
A
N
G
E
L
E
S
,
WA
9
8
3
6
2
,
U
S
A
AP
N
#
06
3
0
1
6
5
3
0
0
1
0
0
0
0
0
UT
I
L
I
T
Y
:
CI
T
Y
O
F
P
O
R
T
A
N
G
E
L
E
S
AH
J
:
CI
T
Y
O
F
P
O
R
T
A
N
G
E
L
E
S
PR
O
J
E
C
T
N
U
M
B
E
R
:
P-
0
0
9
0
3
5
9
14/12/2023LAYOUT CHANGE A
SPEC SHEETS
REVDATEDESCRIPTION
VERSION
UR04/11/2023INITIAL RELEASE
SHEET NAME
SHEET NUMBER
PV-16
PROJECT NAME
SHEET SIZE
ANSI B
11" X 17"
SU
Z
A
N
N
E
M
C
C
O
Y
11
1
W
O
A
K
C
R
E
S
T
A
V
E
,
PO
R
T
A
N
G
E
L
E
S
,
WA
9
8
3
6
2
,
U
S
A
AP
N
#
06
3
0
1
6
5
3
0
0
1
0
0
0
0
0
UT
I
L
I
T
Y
:
CI
T
Y
O
F
P
O
R
T
A
N
G
E
L
E
S
AH
J
:
CI
T
Y
O
F
P
O
R
T
A
N
G
E
L
E
S
PR
O
J
E
C
T
N
U
M
B
E
R
:
P-
0
0
9
0
3
5
9
14/12/2023LAYOUT CHANGE A
SPEC SHEETS
REVDATEDESCRIPTION
VERSION
UR04/11/2023INITIAL RELEASE
SHEET NAME
SHEET NUMBER
PV-17
PROJECT NAME
SHEET SIZE
ANSI B
11" X 17"
SU
Z
A
N
N
E
M
C
C
O
Y
11
1
W
O
A
K
C
R
E
S
T
A
V
E
,
PO
R
T
A
N
G
E
L
E
S
,
WA
9
8
3
6
2
,
U
S
A
AP
N
#
06
3
0
1
6
5
3
0
0
1
0
0
0
0
0
UT
I
L
I
T
Y
:
CI
T
Y
O
F
P
O
R
T
A
N
G
E
L
E
S
AH
J
:
CI
T
Y
O
F
P
O
R
T
A
N
G
E
L
E
S
PR
O
J
E
C
T
N
U
M
B
E
R
:
P-
0
0
9
0
3
5
9
14/12/2023LAYOUT CHANGE A
SPEC SHEETS
ELECTRICAL INSPECTION WIRING REPORT
APPROVED NOT APPROVED
DITCH
ROUGH IN/COVER
SERVICE
FINAL
COMMENTS
NOTIFY INSPECTOR at (360) 808-2613
WHEN CORRECTIONS ARE COMPLETED
WITHIN 15 DAYS
DATE PERMIT # INSPECTOR
2/5/2024 23-1288 TAP
OWNER
CONTRACTOR
Lumio
PROJECT ADDRESS
111 W Oakcrest Ave