HomeMy WebLinkAbout1125 Highland Avenue Address:
1125 Highland Avenue
PREPARED 1/30/15, 9:41:59 INSPECTION TICKET PAGE 3 C�
CITY OF PORT ANGELES -- - INSPECTOR: JAMES LIERLY DATE 1/30/15
- ^
ADDRESS : 1125 HIGHLAND AVE SUBDIV: U
CONTRACTOR C ANDERSON HOMES & DEV INC PHONE (425) 770-1477
OWNER RALSTON JOHN M/GAIL T PHONE
PARCEL 06-30-14-6-9-0050-0000-
APPL NUMBER: 14-00001367 RES NEW SFR
------------------------------------------------------------------------------------------------
PERMIT: BPR 00 BUILDING PERMIT - RESIDENTIAL
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------- -----------------------------------------
BLFW O1 11/19/14 JLL BLDG FOUND FTG/STEM WALL
11/19/14 AP November 19, 2014 9:01:16 AM pbarthol.
Chris 425-770-1477
+x+++xxx+xxxxxxx+ AM +++++xxxxxxxxxxxxx+++x
November 19, 2014 4:46:35 PM jlierly.
DSD O1 11/24/14 JLL BLDG DOWN SPOUT DRAINS
11/24/14 AP November 24, 2014 9:29:13 AM jlierly.
chris
November 24, 2014 4:30:37 PM jlierly.
DRW O1 11/25/14 JLL BLDG DRYWELL
11/25/14 AP November 25, 2014 9:20:04 AM jlierly.
November 25, 2014 3:45:43 PM jlierly.
BFF O1 11/26/14 JLL BLDG FLOOR FRAMING
11/26/14 AP November 26, 2014 10:00:24 AM jlierly.
November 26, 2014 4:05:32 PM jlierly.
BL9 01 12/05/14 JLL BLDG SHEARWALL
12/05/14 AP December 5, 2014 8:52:00 AM pbarthol.
Chris
December 5, 2014 4:04:15 PM jlierly.
BL3 01 12/15/14 JLL BLDG FRAMING
12/15/14 AP December 15, 2014 9:04:55 AM pbarthol.
CHRIS 425-770-1477
December 15, 2014 4:10:26 PM jlierly.
BLI O1 12/17/14 JLL BLDG INSULATION
12/17/14 AP December 16, 2014 10:35:01 AM jlierly.
chris
December 17, 2014 3:00:40 PM jlierly. _
BL99 01 1/30/15 bTL� BLDG FINAL
--��\�¢(J\�, January 30, 2015 9:40:45 AM jlierly.
chris
---------------------- ---------------------------------------------------------
PERMIT: ME 00 MECHANICAL PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
ME1 01 12/15/14 JLL MECHANICAL ROUGH-IN
12/15/14 AP December 15, 2014 9:05:46 AM pbarthol.
December 15, 2014 4:10:26 PM jlierly.
ME99 01 1/30/15 MECHANICAL FINAL
January 30, 2015 9:41:16 AM jlierly.
---
PERMIT: PL 00 PLUMBING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------ -------- -----------
PL6 01 11/25/14 JLL PLUMBING WATER SUPPLY
----------------------------------- CONTINUED ONTO NEXT PAGE -------------------
----------------
PREPARED 1/30/15, 9:41:59 INSPECTION TICKET PAGE 4 .
CITY OF PORT ANGELES INSPECTOR: JAMES LIERLY DATE 1/30/15
------------------------------------------------------------------------------------------------
ADDRESS . : 1125 HIGHLAND AVE SUBDIV:
CONTRACTOR C ANDERSON HOMES & DEV INC PHONE (425) 770-1477
OWNER RALSTON JOHN M/GAIL T PHONE :
PARCEL : 06-30-14-6-9-0050-0000-
APPL NUMBER: 14-00001367 RES NEW SFR
------------------------------------------------------------------------------------------------
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------- ---------------------- .
11/25/14 AP November 25, 2014 9:20:24 AM jlierly.
November 25, 2014 3:45:43 PM jlierly.
PL2 01 12/15/14 JLL PLUMBING ROUGH-IN
12/15/14 AP December 15, 2014 9:05:23 AM pbarthOl.
December 15, 2014 4:10:26 PM jlierly.
PL99 01 1/30/15 L PLUMBING FINAL
January 30, 2015 9:41:30 AM jlierly.
-------------------------- ---------- COMMENTS AND NOTES
-ate CITY OF PORT ANGELES
DEPARTMENT OF COMMUNITY&ECONOMIC DEVELOPMENT-BUILDING DIVISION
321 EAST 5TH STREET, PORT ANGELES,WA 98362
® (ri
Application Number . . . . . 14-00001367 Date 11/18/14
Application pin number . . . 700577
Property Address . . . . . . 1125 HIGHLAND AVE
ASSESSOR PARCEL NUMBER: 06-30-14-6-9-0050-0000- REPORT SALES TAX
Application type description RES NEW SFR
Subdivision Name . . . . . . on your spate excise tax form
Property Use . . . . . . . . to the Cit of Port Angeles
Property Zoning RS7 RESDNTL SINGLE FAMILY s Y y
Application valuation . . . . 147804 (Location Code 0502)
----------------------------------------------------------------------------
Application desc
2303 sq ft SFR
-------------------------------------------------------------------- )
Owner Contractor
------------------------ ------------------------
RALSTON JOHN M/GAIL T C ANDERSON HOMES & DEV INC c�
PO BOX 1405 1400 W. WASHINGTON ST.
PORT ANGELES WA 983620259 STE. 104-178
SEQUIM WA 98382
----- (425) 770-1477
-------------------------------------- ------------------------------
Permit . . . . . . BUILDING PERMIT -RESIDENTIAL
Additional desc . . 2303 SQ FT SFR
Permit Fee . . . . 1289.05 Plan Check Fee 837.88
Issue Date . . . . 11/18/14 Valuation . . . . 147804 1N
Expiration Date 5/17/15
Qty Unit Charge Per Extension
BASE FEE 1020.25
48.00 5.6000 THOU BL-100,001-500K (5.60 PER K) 268.80
----------------------------------------------------------------------------
Permit . . . . . . MECHANICAL PERMIT
Additional desc SFR MECHANICAL
Permit Fee . . . . 171.20 Plan Check Fee .00
Issue Date . . . . 11/18/14 Valuation . . . . 0
Expiration Date 5/17/15
Qty Unit Charge Per Extension
BASE FEE 50.00
1.00 14.8000 EA ME-FURN/HP/FAU < OR = 5 TON 14.80
3.00 7.2500 EA ME-VENT FAN (SINGLE DUCT) 21.75
1.00 10.6500 EA ME-HOOD/DUCT-MECH. EXHAUST 10.65
5.00 14.8000 EA ME-HEATER(SUSP/WALL/FLOOR-MTD)-- 74.00
- ----------------------------------
Permit . . . . . . PLUMBING PERMIT S"
Additional desc SFR PLUMBING
Permit Fee 163.00 Plan Check Fee .00
Issue Date . . . . 11/18/14 Valuation . . . . 0
Expiration Date 5/17/15
Qty Unit Charge Per Extension
BASE FEE 50.00
8.00 7.0000 EA PL-PLUMBING TRAP 56.00
1.00 7.0000 EA PL-WATER LINE 7.00
Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes
null and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned
for a period of 180 days after the work has commenced, or if required inspections have not been requested within 180 days from the
last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions
of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does
not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construction.
Date Print Name Signature of Contractor or A horized Agent Signature of Owner(if owner is builder)
T:Forms/Building Division/Building Permit
PW a
BUILDING PERMIT INSPECTION RECORD
PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS—
Building Inspections 417-4815 Electrical Inspections 417-4735
Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886
IT IS UNLAWFUL TO COVER,INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED.
POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE.
Inspection Type Date Accepted By Comments
FOUNDATION:
Footings
Stemwall
Foundation Drainage/Downspouts
Piers
Post Holes(Pole Bldgs.)
PLUMBING:
Under Floor/Slab
Rough-In
Water Line Meter to Bldg)
Gas Line
Back Flow/Water FINAL Date Accepted b
AIR SEAL:
Walls
Ceiling
FRAMING:
Joists/Girders/Under Floor
Shear Wall/Hold Downs
Walls/Roof/Ceiling
Drywall Interior Braced Panel Only)
T-Bar
INSULATION:
Slab
Wall/Floor/Ceiling
MECHANICAL:
Heat Pum /Furnace/FAU/Ducts
Rough-in
Gas Line
Wood Stove/Pellet/Chimney
Commercial Hood/Ducts FINAL Date Accepted b
MANUFACTURED HOMES:
Footing/Slab
Blocking&Hold Downs
Skirting
PLANNING DEPT. Separate Permit#s SEPA:
Parkin /Lighting ESA:
Landscaping SHORELINE:
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE
Inspection Type Date Accepted By
Electrical 417-4735
Construction-R.W. PW I Engineering 417-4831
Fire 417-4653
Planning 417-4750
Building 417-4815
T:Forms/Building Division/Building Permit
CITY OF PORT ANGELES
DEPARTMENT OF COMMUNITY& ECONOMIC DEVELOPMENT- BUILDING DIVISION
321 EAST 5TH STREET, PORT ANGELES,WA 98362
Page 2
Application Number . . . . . 14-00001367 Date 11/18/14
Application pin number 700577
Qty Unit Charge Per Extension REPORT SALES TAX
4.00 7.0000 EA PL-DRAIN VENT PIPING 28.00 on your state excise tax form
1.00 15.0000 EA PL-SEWER LINE 15.00 to the Cit of Port Angeles
1.00 7.0000 EA PL-WATER HEATER 7.00 Y
-------------------------------------------------------------- -------------- (Location Code 0502)
Special Notes and Comments
N tuber 10, 2014 12:17:30 PM sroberds.
The p al as shown�exceeds lot 5 sq.ft. o %
2$. This is n on. There should not be a nee
viation at thNovember 10, 2014 9:1M tamiot.
ELECTRICAL PERMIT WILL BE REQUIRED.
ELECTRICAL SERVICE SHALL BE UNDERGROUND TO THE EXISTING
PEDESTAL AT THE SOUTH/WEST CORNER, NOT THE TRANSFORMER.
November 10, 2014 7:25:55 AM rbecker.
If you are installing a lawn or fire sprinkler system, you
will need to install a backflow assembly.
Call Ron Becker @360-417-4886, fax:360-452-4972, or
E-mail:rbecker@cityofpa.us
Address numbers shall be plainly visible from the street.
Address numbers shall be a minimum of six inches high and be
of contrasting color from the background.
November 10, 2014 12:12:25 PM sroberds.
As proposed, the construction exceeds lot coverage by 165
sq.ft. or 2%. This is new development so should not require
a minor deviation as the developer can reduce the foot print
at this point.
November 17, 2014 3:37:15 PM sroberds.
The proposal will result in a new sfr in the RS-7 for total
lot cov of 29% and site cov of 41%. No land use issues
anticipated as proposed.
1. Establishing Construction Access.
2. Install sediment controls BMPs.
3. Stabilize exposed soils.
4. Protect slopes from erosion.
5. Protect drain inlets.
6. Control pollutants including but not limited to spills,
concrete wash out, exposed aggregate processes, concrete
grinding and saw cut waste water.
7. Maintain temporary and permanent erosion control BMPS
during project.
Consider applying for the City Green Infrastructure Rebate
of up to $750.00 towards the materials to install rain
garden to control roof and driveway runoff. Also rebates
available for downspout disconnections.Contact Jonathan
Boehme at 360 417-4811
Trench safety per applicable laws. Temp erosion control and
surface restoration responsibility of applicant. Contact
City inspector prior to start of work @ 360 417-4831. No
attachment to sanitary sewer of stormwater roof leaders,
foundation drains, yard drains, or any other CSO
Separate Permits are required forelectrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes
null and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned
for a period of 180 days after the work has commenced, or if required inspections have not been requested within 180 days from the
last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions
of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does
not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construction.
Date Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder)
T:Forms/Building Division/Building Permit
BUILDING PERMIT INSPECTION RECORD
PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS-
Building Inspections 417-4815 Electrical Inspections 417-4735
Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886
IT IS UNLAWFUL TO COVER,INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED.
POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE.
Inspection Type Date Accepted By Comments
FOUNDATION:
Footings
Stemwall
Foundation Drainage/Downspouts
Piers
Post Holes(Pole Bldgs.)
PLUMBING:
Under Floor/Slab
Rough-In
Water Line Meter to Bldg)
Gas Line
Back Flow/Water FINAL Date Accepted b
AIR SEAL:
Walls
Ceiling
FRAMING:
Joists/Girders/Under Floor
Shear Wall/Hold Downs
Walls/Roof/Ceiling
Drywall Interior Braced Panel Only)
T-Bar
INSULATION:
Slab
Wall/Floor/Ceiling
MECHANICAL:
Heat Pum /Furnace/FAU/Ducts
Rough-in
Gas Line
Wood Stove/Pellet/Chimney
Commercial Hood/Ducts FINAL Date Accepted b
MANUFACTURED HOMES:
Footing/Slab
Blocking&Hold Downs
Skirting
PLANNING DEPT. Separate Permit#s SEPA:
Parkin /Lighting ESA:
Landscaping SHORELINE:
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE
Inspection Type Date Accepted By
Electrical 417-4735
Construction-R.W. PW I Engineering 417-4831
Fire 417-4653
Planning 417-4750
Building 417-4815
T:Forms/Building Division/Building Permit
CITY OF PORT ANGELES
�. DEPARTMENT OF COMMUNITY&ECONOMIC DEVELOPMENT- BUILDING DIVISION
�-- 321 EAST 5TH STREET, PORT ANGELES,WA 98362
Page 3
Application Number . . . . . 14-00001367 Date 11/18/14
Application pin number . . . 700577
---------------------------------------------------------------------------- REPORT SALES TAX
Special Notes and Comments
contribution is allowed. on your state excise tax form
Sanitary sewer connection inspection is required by to the City of Port Angeles
Public Works prior to back fill of ditch. 24 hour advance
notice is required. Public Works Inspection request line (Location Code 0502)
417-4831
Utilize existing driveway opening at it's current location.
Construct driveway to City Standards. Concrete with exposed
aggregate or other non-standard finishes(including colors or
dyes)are not allowed in the City road right of way. Broom
finish only. An inspection by Public Works Engineering is
required prior to pouring concrete. Public Works inspection
request line 417-4831
A separate Right of Way Construction permit is required by
the contractor for driveway work.
----------------------------------------------------------------------------
Other Fees . . . . . . . . RES UNDERGRND SERVICE FEE 770.00
SEWER SYSTEM DELV CHARGE 2260.00
STATE SURCHARGE 4.50
PW WATER SYSTEM USE FEE 2260.00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 1623.25 1623.25 .00 .00
Plan Check Total 837.88 837.88 .00 .00
Other Fee Total 5294.50 5294.50 .00 .00
Grand Total 7755.63 7755.63 .00 .00
Separate Permits are required forelectrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes
null and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned
for a period of 180 days after the work has commenced, or if required inspections have not been requested within 180 days from the
last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions
of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does
not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construction.
Date Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder)
T:Forms/Building Division/Building Permit
BUILDING PERMIT INSPECTION RECORD
-- PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS--
Building Inspections 417-4815 Electrical Inspections 417-4735
Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886
IT IS UNLAWFUL TO COVER,INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED.
POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE.
Inspection Type Date Accepted By Comments
FOUNDATION:
Footings
Stemwall
Foundation Drainage/Downspouts
Piers
Post Holes(Pole Bldgs.)
PLUMBING:
Under Floor/Slab
Rou h-In
Water Line Meter to Bldg)
Gas Line
Back Flow/Water FINAL Date Accepted b
AIR SEAL:
Walls
Ceiling
FRAMING:
Joists/Girders/Under Floor
Shear Wall/Hold Downs
Walls/Roof/Ceiling
Drywall Interior Braced Panel Only)
T-Bar
INSULATION:
Slab
Wall/Floor/Ceiling
MECHANICAL:
Heat Pum /Furnace/FAU/Ducts
Rough-In
Gas Line
Wood Stove/Pellet/Chimney
Commercial Hood/Ducts FINAL Date Accepted b
MANUFACTURED HOMES:
Footing/Slab
Blocking 8 Hold Downs
Skirting
PLANNING DEPT. Separate Permit#s SEPA:
Parkin /Lighting ESA:
Landscaping SHORELINE:
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE
Inspection Type Date Accepted By
Electrical 417-4735
Construction-R.W. PW I Engineering 417-4831
Fire 417-4653
Planning 417-4750
Building 417-4815
T:Forms/Building Division/Building Permit
• °`� °F� CITY OF PORT ANGELES
PUBLIC WORKS &UTILITIES
321 EAST 5TH STREET, PORT ANGELES,WA 98362
Application Number . . . . . 14-00001367 Date 11/18/14
Application pin number . . . 700577
Property Address . . . . . . 1125 HIGHLAND AVE
ASSESSOR PARCEL NUMBER: 06-30-14-6-9-0050-0000- REPORT SALES TAX
Application type description RES NEW SFR
Subdivision Name . . . . . . on your State excise tax form
Property Use . . . . . . . . to the City of Port Angeles
Property Zoning . . . . . . . RS7 RESDNTL SINGLE FAMILY
Application valuation . . . . 147804 (Location Code 0502)
----------------------------------------------------------------------------
Application desc
2303 sq ft SFR
----------------------------------------------------------------------------
Owner Contractor
------------------------ ------------------------
RALSTON JOHN M/GAIL T C ANDERSON HOMES & DEV INC
PO BOX 1405 1400 W. WASHINGTON ST.
PORT ANGELES WA 983620259 STE. 104-178
SEQUIM WA 98382
(425) 770-1477
----------------------------------------------------------------------------
Permit . . . . . . DRIVEWAY INSTALLATION
Additional desc . .
Permit Fee . . . . 180.00 Plan Check Fee .00
Issue Date . . . . 11/18/14 Valuation . . . . 0
Expiration Date . . 5/17/15
Qty Unit Charge Per Extension
BASE FEE 180.00
----------------------------------------------------------------------------
Permit . . . . . . PUBLIC WORKS RES WATER SERV
Additional desc . . 5/8" DROP IN METER
Permit Fee . . . . 420.00 Plan Check Fee .00
Issue Date . . . . 11/18/14 Valuation . . . . 150156
Expiration Date 5/17/15
Qty Unit Charge Per Extension
1.00 420.0000 EA PW WATER METER DROP IN 420.00
----------------------------------------------------------------------------
Permit . . . . . . SANITARY SEWER HOOK UP
Additional desc . .
Permit Fee . . . . 150.00 Plan Check Fee .00
Issue Date . . . . 11/18/14 Valuation . . . 150156
Expiration Date . . 5/17/15
Qty Unit Charge Per Extension
1.00 150.0000 EA SAN SEWER HOOKUP 150.00
----------------------------------------------------------------------------
Special Notes and Comments
November 10, 2014 12:17:30 PM sroberds.
The proposal as shown exceeds lot coverage by 165 sq.ft. or
2t. This is new construction. There should not be a need
for a deviation at this point.
November 10, 2014 9:18:26 AM tamiot.
Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes
null and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned
for a period of 180 days after the work as commenced,or if required inspections have not been requested within 180 days from the last
inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of
laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not
presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construction.
ignature of ContractoCWr Authorized Agent Date Signature of Owner(if owner is builder) Date
T:Forms/Building Division/Public Works Permit
PERMIT INSPECTION RECORD
CALL 417-4831 FOR UTILITY INSPECTIONS. PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAWFUL TO COVER,
INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT INA CONSPICUOUS LOCATION.
KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE
INSPECTION TYPE DATE ACCEPTED COMMENTS
YES NO
PW UTILITIES (Engineering Division)
WATERLINE/METER
SEWER CONNECTION
SANITARY
STORM
SITE DRAINAGE
SITE EROSION CONTROL
PARKING
SIDEWALK
CURB&GUTTER
DRIVEWAY APPROACH
BACK-FLOW DEVICE
r
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE
RESIDENTIAL DATE YES NO COMMERCIAL DATE ACCEPTED
YES NO
CONSTRUCTION R.W./PW/ CONSTRUCTION-R.W.
ENGINEERING 4174807 PW/ENGINEERING
FIRE 417.4653 FIRE DEPT.
PLANNING DEPT. 417-4750 PLANNING DEPT.
BUILDING 4'17- BUILDING
4815
T:Fortns/Building Division/Public Works Permit
CITY OF PORT ANGELES
PUBLIC WORKS & UTILITIES
321 EAST 5TH STREET, PORT ANGELES, WA 98362
Page 2
Application Number . . . . . 14-00001367 Date 11/18/14
Application pin number . . . 700577
---------------------------------------------------------------------------- REPORT SALES TAX
Special Notes and Comments our state excise tax form
ELECTRICAL PERMIT WILL BE REQUIRED. on Y
ELECTRICAL SERVICE SHALL BE UNDERGROUND TO THE EXISTING to the City of Port Angeles
PEDESTAL AT THE SOUTH/WEST CORNER, NOT THE TRANSFORMER.
November 10, 2014 7:25:55 AM rbecker. (Location Codec 0502
If you are installing a lawn or fire sprinkler system, you
will need to install a backflow assembly.
Call Ron Becker @360-417-4886, fax:360-452-4972, or
E-mail:rbecker@cityofpa.us
Address numbers shall be plainly visible from the street.
Address numbers shall be a minimum of six inches high and be
of contrasting color from the background.
November 10, 2014 12:12:25 PM sroberds.
As proposed, the construction exceeds lot coverage by 165
sq.ft. or 2t. This is new development so should not require
a minor deviation as the developer can reduce the foot print
at this point.
November 17, 2014 3:37:15 PM sroberds.
The proposal will result in a new sfr in the RS-7 for total
lot cov of 29t and site cov of 41t. No land use issues
anticipated as proposed.
1. Establishing Construction Access.
2. Install sediment controls BMPs.
3. Stabilize exposed soils.
4. Protect slopes from erosion.
5. Protect drain inlets.
6. Control pollutants including but not limited to spills,
concrete wash out, exposed aggregate processes, concrete
grinding and saw cut waste water.
7. Maintain temporary and permanent erosion control BMPS
during project.
Consider applying for the City Green Infrastructure Rebate
of up to $750.00 towards the materials to install rain
garden to control roof and driveway runoff. Also rebates
available for downspout disconnections.Contact Jonathan
Boehme at 360 417-4811
Trench safety per applicable laws. Temp erosion control and
surface restoration responsibility of applicant. Contact
City inspector prior to start of work @ 360 417-4831. No
attachment to sanitary sewer of stormwater roof leaders,
foundation drains, yard drains, or any other CSO
contribution is allowed.
Sanitary sewer connection inspection is required by
Public Works prior to back fill of ditch. 24 hour advance
notice is required. Public Works Inspection request line
417-4831
Utilize existing driveway opening at it's current location.
Construct driveway to City Standards. Concrete with exposed
aggregate or other non-standard finishes(including colors or
dyes)are not allowed in the City road right of way. Broom
finish only. An inspection by Public Works Engineering is
Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements.This permit becomes
null and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned
for a period of 180 days after the work as commenced,or if required inspections have not been requested within 180 days from the last
inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of
laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not
presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construction.
Signature of Contractor or Authorized Agent Date Signature of Owner(if owner is builder) Date
T:Forms/Building Division/Public Works Permit
PERMIT INSPECTION RECORD
CALL 4174831 FOR UTILITY INSPECTIONS. PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAWFUL TO COVER,
INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT INA CONSPICUOUS LOCATION.
KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE
INSPECTION TYPE DATE ACCEPTED COMMENTS
YES NO
PW UTILITIES (Engineering Division)
WATERLINE/METER
SEWER CONNECTION
SANITARY
STORM
SITE DRAINAGE
SITE EROSION CONTROL
PARKING
SIDEWALK
CURB&GUTTER
DRIVEWAY APPROACH
BACK-FLOW DEVICE
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE
RESIDENTIAL DATE YES NO COMMERCIAL DATE ACCEPTED
YES NO
CONSTRUCTION R.W./PW/ CONSTRUCTION-R.W.
ENGINEERING 417-4807 PW/ENGINEERING
FIRE 417-4653 FIRE DEPT.
PLANNING DEPT. 4174750 PLANNING DEPT.
BUILDING 4'17- BUILDING
4815
T:Fonns/Building Division/Public Works Permit
• 4~OF PO��kN
CITY OF PORT ANGELES
PUBLIC WORKS & UTILITIES
321 EAST 5TH STREET, PORT ANGELES,WA 98362
Page 3
Application Number . . . . . 14-00001367 Date 11/18/14
Application pin number . . . 700577
---------------------------------------------------------------------------- REPORT SALES TAX
Special Notes and Comments
required prior to pouring concrete. Public Works inspection on your state excise tax form
request line 417-4831 to the City of Port Angeles
A separate Right of Way Construction permit is required by
the contractor for driveway work. (Location Code 0502)
----------------------------------------------------------------------------
Other Fees . . . . . . . . . RES UNDERGRND SERVICE FEE 770.00
SEWER SYSTEM DELV CHARGE 2260.00
STATE SURCHARGE 4.50
PW WATER SYSTEM USE FEE 2260.00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 750.00 750.00 .00 .00
Plan Check Total .00 .00 .00 .00
Other Fee Total 5294.50 5294.50 .00 .00
Grand Total 6044.50 6044.50 .00 .00
Separate Permits are required forelectrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes
null and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned
for a period of 180 days after the work as commenced,or if required inspections have not been requested within 180 days from the last
inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of
laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not
presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construction.
Signature of Contractor or Authorized Agent Date Signature of Owner(if owner is builder) Date
T:Forms/Building Division/Public Works Permit
PERMIT INSPECTION RECORD
CALL 417-4831 FOR UTILITY INSPECTIONS. PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAWFUL TO COVER,
INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT INA CONSPICUOUS LOCATION.
KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE
INSPECTION TYPE DATE ACCEPTED COMMENTS
YES NO
PW UTILITIES (Engineering Division)
WATERLINE/METER
SEWER CONNECTION
SANITARY
STORM
SITE DRAINAGE
SITE EROSION CONTROL
PARKING
SIDEWALK
CURB&GUTTER
DRIVEWAY APPROACH
BACK-FLOW DEVICE
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE
RESIDENTIAL DATE YES NO COMMERCIAL DATE ACCEPTED
YES NO
CONSTRUCTION R.W./PW/ CONSTRUCTION-R.W.
ENGINEERING 417-4807 PW/ENGINEERING
FIRE 417.4653 FIRE DEPT.
PLANNING DEPT. 4174750 PLANNING DEPT.
BUILDING 07- BUILDING
4815
T:Forms/Building Division/Public Works Permit
THF-
"'OLES
CITY OF _ For City Use
0- A�
W A S H I N G T O N} U �
Permit# le-l-t3
Date Received: //_ 7-
321 East 51' Street '
Port Angeles, WA 98362 , Date Approved /� 5/1 C/
P: 360-417-4817 F: 360-417-4711
permits@cityofpa.us
Building Permit Applic tion
Project Address:
1125 Highland Avenue, Port Angeles WA 98362
Main Contact: Phone # 360-504-1198
Christopher Anderson
E-Mail: Chris@candersonhomes.com
Property Name John M and Gail T Ralston Phone 360-504-1198
Owner Mailing Address Email
495 W. Spruce St., Suite 3 chris@candersonhomes.com
city Sequim,WA 98382 state WA Zip 98382
Contractor Na1e C. Anderson Homes&Development, Inc. Phone 360-504-1198
Mailing Address 495 W. Spruce St. Suite 3 Email
p , Chris@candersonhomes.com
city Sequim,WA 98382 state WA Zip 98382
Contractor License# Expiration:
CANEAH943DG March 17,2016 j
Project Value: Zoning: Tax Parcel# Lot#
$ 119,000.00 06-30-14-69-0050 7
Type of Residential ® Commercial ❑ Industrial ❑ Public ❑
Permit Demolition ❑ Fire ❑ Repair ❑ Reroof(tear off/lay over) ❑
For the following,fill out both pages of permit application:
New Construction M Remodel ❑ Addition ❑ Tenant Improvement ❑
Mechanical ❑ Plumbing ❑ Other ❑
Existing Fire Sprinkler System? Maximum height of structure Proposed Bedrooms Proposed Bathrooms
Yes [3No ® T 15' 2 2
Project New Single Family Construction
Description
I have read and completed the application and know it to be true and correct.I am authorized to apply for this
permit. I understand that it is my responsibility to determine what permits are required and to obtain permits
prior to working on projects. I understand that the plan review fee is not refundable after plan review has
occurred. I understand that I will forfeit the review fee if I cancel or withdraw the application before the
permit is issued. I understand that if the permit is not issued within 180 days of receipt,the application will be
considered abandoned and the fees forfeit.
Date Print Name Signatur -�
11-07-14 Christopher Anderson
Residential Structures
For Office Use
Area Description(SQ FT) Existing Proposed $$value
Basement 0 0
First Floor 0 1548 /l1/S t O
econd Floor 0 0
Covered Deck/Porch/Entry 0
Deck 0 0
Garage 0 528
Carport 0 0
Other(describe) 0 0
Area Totals 0 - f Icl-7 f!V
Commercial Structures
For Office Use
Area Descriptions(SQ FT) Existing Proposed $$Value
Existing Structure(s)
Proposed Addition
Tenant Improvement?
Other work(describe)
Area Totals
LotlSite Coverage Calculations
Footprint(SQ FT)of all Structures: Lot Size: %Lot Coverage p
, 2>� (0 7,165
SQ FT Site coverage fall impe�47
+ 7,165 %Site Coverage
structures 3 .8
Mechanical Fixtures
Indicate how many of each type of fixture to be installed or relocated as part of this promect.
Air Handler Size: # 0 Haz/Non-Haz Piping #of Outlets:
Appliance Vent # 1 Heater(Suspended,Floor,Recessed wall) # 5
Boiler/Compressor Size: # 0 Heating/Cooling appliance # 0
repair/alteration
Evaporative Cooler(attached,not # 0 Pellet Stove/Wood-burning/Gas # 0
portable) Fireplace/Gas Stove Gas Cook Stove/Misc.
Fuel Gas Piping . #of Outlets: Ventilation Fan,single duct # 3
Furnace/Heat Pump/ Size: # 1 Ventilation System # 0
Forced Air Unit Ductless Mini
Plumbing Fixtures
Indicate how many of each type of fixture to be installed or relocated
Plumbing Traps # g Fuel gas piping #of Outlets: 0
Water Heater # 1 Medical gas piping #of Outlets: 0
Water Line # 1 Vent piping # 4
Sewer Line # 1 Industrial waste pretreatment # 0
interceptor
Other(describe):
T:\BUILDING\APPLICATION FORMS\BUILDING PERMIT 081212.DOCX
64.04' P. L .
N/ N/
20.00' S.B.
o CA-1548 I �)
ca N .
!V rW _ LOT 7 N
71165 Sq. Ft.
Jv is
20.00' S.B.
6 3.9 1 ° P. L .
1125 Highland Ave
CA
HOMES AO
PLAN# Lot 7-1125 Highland Ave,Port Angeles,WA 98362 Cad@'
CA-1125Presold Spec Home V_101.0•
X1'(34
1142
p
3
5
t�. 2
d
d
s
F
t
ryti
4 id 6 �'kK't � wWk2 ���
,T
X137.
4
Highland-A ve--,-,.� F
(16
� r
rr
1122" r 113$
1132
r
f
111
6 ._
Prescriptive Energy Code Compliance for All Climate Zones in Washington
Project Information Contact Information
Lot 7 12 i' Aver °` ° ,Andersaq Hames
Port Angeles 11tR 98362 ': . E Christopher Antlerson .
John M OAMd ll T Ralston
This project will use the requirements of the Prescriptive Path below and incorporate the
the minimum values listed. In addition, based on the size of the structure,the appropriate
number of additional credits are checked as chosen by the permit applicant.
Authorized Representative Date
All Climate Zones
R-Valuea U-Factor'
Fenestration U-Factorb n/a 0.30
Skylight U-Factor n/a 0.50
Glazed Fenestration SHGCb,e n/a n/a
Ceiling 49' 0.026
Wood Frame Wali9,k.' 21 int 0.056
Mass Wall R-Value' 21/21' 0.056
Floor 309 0.029
Below Grade Wall`,k 10/15/21 int+TB 0.042
Slab R-Value&Depth 10,2 ft n/a
*Table R402.1.1 and Table R402.1.3 Footnotes included on Page 2.
Each dwelling unit in one and two-family dwellings and townhouses,as defined in Section 101.2 of the
International Residential Code shall comply with sufficient options from Table R406.2 so as to achieve the
following minimum number of credits:
❑1.Small Dwelling Unit: 0.5 points
Dwelling units less than 1500 square feet in conditioned floor area with less than 300 square feet of fenestration
area. Additions to existing building that are less than 750 square feet of heated floor area.
02. Medium Dwelling Unit: 1.5 points
All dwelling units that are not included in#1 or#3, including additions over 750 square feet.
❑3. Large Dwelling Unit: 2.5 points
Dwelling units exceeding 5000 square feet of conditioned floor area.
Table R406.2 Summary
Option Description Credit(s)
la Efficient Building Envelope 1 a 0.5 ❑
lb Efficient Building Envelope lb 1.0 ❑
1c Efficient Building Envelope 1c 2.0 ❑
2a Air Leakage Control and Efficient Ventilation 2a 0.5 ❑
2b Air Leakage Control and Efficient Ventilation 2b 1.0 ❑
2c Air Leakage Control and Efficient Ventilation 2c 1.5 ❑
3a High Efficiency HVAC 3a 0.5 ❑
3b High Efficiency HVAC 3b 1.0 ❑
3c High Efficiency HVAC 3c 2.0 ❑
3d High Efficiency HVAC 3d 1.0 0 1.0
4 High Efficiency HVAC Distribution System 1.0 ❑
5a Efficient Water Heating 0.5 0 0.5
5b Efficient Water Heating 1.5 ❑ ,
6 Renewable Electric Energy 0.5 *1200 kwh 0.0
Total Credits 1.50
*Please refer to Table R406.2 for complete option descriptions
http://www.energy.wsu.edu/Documents/2012%20Res%20Energy.pdf
` TM:
Table R402.1.1 Footnotes
• For SI: 1 foot.=304.8 mm, ci .= continuous insulation, int .= intermediate framing.
a R-values are minimums. U-factors and SHGC are maximums.When insulation is installed in a cavity which is
less than the label or design thickness of the insulation,the compressed R-value of the insulation from
Appendix Table A101.4 shall not be less than the R-value specified in the table.
b The fenestration U-factor column excludes skylights.The SHGC column applies to all glazed fenestration.
Exception:.Skylights may be excluded from glazed fenestration SHGC requirements in Climate Zones 1
through 3 where the SHGC for such skylights does not exceed 0.30.
"10/15/21.+TB" means R-10 continuous insulation on the exterior of the wall,or R-15 on the continuous
insulation on the interior of the wall, or R-21 cavity insulation plus a thermal break between the slab and the
basement wall at the interior of the basement wall. "10/15/21.+TB" shall be permitted to be met with R-13
cavity insulation on the interior of the basement wall plus R-5 continuous insulation on the interior or
exterior of the wall. "10/13" means R-10 continuous insulation on the interior or exterior of the home or R-
13 cavity insulation at the interior of the basement wall. "TB" means thermal break between floor slab and
basement wall.
d R-10 continuous insulation is required under heated slab on grade floors.See R402.2.9.1.
e There are no SHGC requirements in the Marine Zone.
f Basement wall insulation is not required in warm-humid locations as defined by Figure R301.1 and Table
R301.1.
g Reserved.
h First value is cavity insulation, second is continuous insulation or insulated siding, so "13.+5" means R-13
cavity insulation plus R-5 continuous insulation or insulated sidin;.:. If structural sheathing covers 40 percent
or less of the exterior, continuous insulation R-value shall be permitted to be reduced by no more than R-3 in
the locations where structural sheathing is used to maintain a consistent total sheathing thickness.
'The second R-value applies when more than half the insulation is on the interior of the mass wall.
For single rafter-or joist-vaulted ceilings,the insulation may be reduced to R-38.
k Int. (intermediate framing)denotes standard framing 16 inches on center with headers insulated with a
minimum of R-10 insulation.
Log and solid timber walls with a minimum average thickness of 3.5 inches are exempt from this insulation
requirement.
Table R402.1.3 Footnote
a Nonfenestration U-factors shall be obtained from measurement, calculation or an approved source or as
specified in Section R402.1.3.
Glazing Schedule
Project Information Contact Information
Lot 7-1125 Highland Avenue IC.Anderson Homes
Port Angeles,WA 98362 1 Christopher Anderson
John M and Gail T Ralston 360-504-1198
R402.3.3 Exception(15 sq.ft.max.)
Vertical Glazing(Windows and glazed doors)
Plan Component Glazing Width Height Glazing
ID Description Ref. U-factor Qt. Feet Inch Feet inch Area UA
•;
Naster..Bedroom,. . 77720.0 6.00
Bedroom#1„ ,..... ' 030• 1:`... 4. . 4.., 13.0 4.80
n
0.30__ . 1`'° .5ll, :Pk,„141 '. 20.0 6.00
s
eatrvgin.2-n' 0:30.,, a1 8 w. i- ° 40.0 12.00
m� 77
ET_ L?ItUTt'Root , .. -= 0:30..,." 1 5 o 6 :A� 34.2 10.25
Kttcher�..- 12.0 3.60
EWE ��' Master Bath E 0.30,,. E 4-` ° 4 • 16.0 4.80
0.0 0.00
. , 0.0 0.00
0.0 0.00
0.0 0.00
74
zN ' 1 0.01 0.00
, .. ` 0.0 0.00
�. 0.0 0.00
Mi
0.0 0.00
77
0.0 0.00
0.0 0.00
ti .-
"w„ 0.0 0.00
A
0.0 0.00
. 0.0 0.00
0.0 0.00
77
0.0 0.00
6:., ! „ = 0.0 0.00
0.0 0.00
177771
77 0.0 0.00
, „ 0.0 0.00
., ,. 'x 0.01 0.00
0.0 0.00
0.0 0.00
.a, ... 0.0 0.00
�.
r ,. ..: Alx"� � .. � �... 0.0 0.00
�= a 0.0 0.00
MA "t� °� .,...,r.-� . _ >�" 0.0 0.00
.Si' = . 0.0 0.00
0.0 0.00
0.0 0.00
y 0.0 0.00
0.0 0.00
0.0 0.00
777 0.0 0.00
7777
0.0 0.00
% \ 'W,:1 _ ,.. 0.0 0.00
Sum of Area and UA 1 158.21 47.45
Area Weighted U=UA/Area 1 0.30
Simple Heating System Size:Washington State
This heating system sizing calculator is based on the Prescriptive Requirements of the 2012 Washington State Energy Code(WSEC)and ACCA
Manuals J and S.This calculator will calculate heating loads only.ACCA procedures for sizing cooling systems should be used to determine cooling
loads.
The glazing(window)and door portion of this calculator assumes the installed glazing and door products have an area weighted average U-factor of
0.30. The incorporated insulation requirements are the minimum prescriptive amounts specified by the 2012 WSEC.
Please fill out all of the green drop-downs and boxes that are applicable to your project.As you make selections in the drop-downs for each section,
some values will be calculated for you.If you do not see the selection you need in the drop-down options,please call the WSU Energy Extension
Program at(360)956-2042 for assistance.
Project Information Contact Information
... Pc
17110 .GiAntlersa em
L°ot 1-_• 5Highland.Ave__ ot H_
_:
Port`Angeles.WA 98362 „j- .._ :` Christopher Antlerson
John M and Gail"T.Etalsta`' yF:" `: .�.. . . .... 360-404'414&
Heating System Type: ( II Other Systems OHeat Pump
To see detailed instructions for each section,place your cursor on the word"Instructions".
Design Temperature
Instruction �,fr Design Temperature Difference(OT) 42
Port Angeles AT=Indoor(70 degrees)-Outdoor Design Temp
Area of Building
Conditioned Floor Area
Instructions Conditioned Floor Area(sq ft) _, 1 548
Average Ceiling Height Conditioned Volume
Instrua tions Average Ceiling Height(ft) '` �X8:0 12,384
Glazing and Doors J-;:actor X Area UA
Instructions
0.30 w 1 a8 47.46
Skylights U-Factor X Area UA
3:�strur.4icsns 0.50 �•; 0 :.._:. ---
Insulation
Attic U-Factor X Area UA
Instructions
R-49 0.026 .1,548:., 40.25
Single Rafter or Joist Vaulted Ceilings LI-Factor X Area UA
.._
instructions
No Vaulted Ceilings in this project. ___�v�:;� a`,�'�i.
Above Grade Walls(see Figure 1) U-Factor X Area UA
Instructions `
R 27 Intermediate 0.0561 r46';' 81.54
Floors U-Factor X Area UA
Instructions 0.029 ``'::1548 44.89
R-30 :z
Below Grade Walls(see Figure'1) LI-Factor X Area UA
(nsti'11r.4icsn�, No Below Grade Walls in this project. •' --- ---
Slab Below Grade(see Figure a F-Factor XLon th UA
• No Slab Below Grade in this project.
Slab on Grade(see Figure 1) F-Factor XLeh UA
Insirtict.t ns "'
No Slab on Grade in this project. v n ; �••�'
Location of Ducts
Instructions r.—._ - ---- •"" Duct Leakage Coefficient
Unconditioned Space ,
1.1
Sum of UA 214.14
Envelope Heat Load 8,994 Btu/Hour
Figure 1. SumofuaxeT
Air Leakage Heat Load 5,617 Btu/Hour
VolumeX 0.6XATX.018
Above Grade Building Design Heat Load 14,611 Btu/Hour
Air Leakage+Envelope Heat Loss
Building and Duct Heat Load 16,072 Btu/Hour
Ducts in unconditioned space:Sum of Building Heat Loss X 1.10
Ducts in conditioned space:Sum of Building Heat Loss X 1
Maximum Heat Equipment Output 22,501 Btu/Hour
Building and Duct Heat Loss X 1.40 for Forced Air Furnace
Building and Duct Heat Loss X 1.25 for Heat Pump
(07/01/13)
SOUND STRUCTURAL SOLUTIONS
E N G I N E E R S
November 17, 2014
To: Chris Anderson, C Anderson Homes & Development
From: Damon Fleming, PE
Re: Plan CA-1548
Remove porch roof
SSS# s1411002
Removing the porch roof does not change the shearwall design. All shearwall and
holdown specifications remain the same on structural plans dated 11/7/2014 whether
the roof is constructed or not.
If you have any questions or require additional information, please call.
FL-9
of S"
4
42
6628 212th Street SW,Suite 205 - Lynnwood,WA 98036 - Ph:425-778-1023 - Fax:206-260-7490
MITSUBISHI .� M Ir.SS II� M®
ELECTRIC
Split ductless A/C and Heat Pumps
SUBMITTAL DATA: MSZ-FE12NA & ` 12,000 BTU/H WALL-MOUNTED HEAT PUMP SYSTEM
,lob Name: 1125 Highland Avenue Location: Port Angeles, WA Date: 11-07-14
Purchaser: C. Anderson Homes Engineer: Absolute Air
Submitted to: City Of Port Angeles For ❑Reference ❑Approval ❑■Construction
Unit Designation: Great Room Schedule No.:
GENERAL FEATURES
•Highly energy-efficient system that features 92%heating capacity 1
at 5°F,75%at-4•F,and 58%at-13•F '
•Updated sleek,compact indoor unit design
•Includes Standard,Platinum Deodorizing,and Anti-allergy Enzyme
filters for a complete air purifying system
"Powerful Mode"function permits system to temporarily run at -
a lower/higher temperature with an increased fan speed,Which _ Indoor Unit:MSZ-FE12NA f
quickly brings the room to the optimum comfort level
•Integrated i-see Sensor automatically adjusts the unit's operation 191
according to temperature differences detected between the floor G1
and the intake air,ensuring optimum comfort and energy usage
•Wireless remote controller
•Base heater is available as an option Controller
Limited
- r
•Limited warranty:five years on parts and defects and seven years on
compressors -- Outdoor Unit:MUZ-FE12NA
OPTIONAL ACCESSORIES Indoor Unit
Outdoor Unit MCA.. .. . . . .. .. . .... .. .. .. .. . ... .. . .. .. ..... . .. ....
•Base Heater(MAC-640BH-U)
Fan Motor ... . .. . ... ... .... .. ... . .. ... ....... . 0.76 F.L.A.
•Drain Socket(MAC-851 DS) Airflow
Indoor Unit Cooling(Lo-Med-Hi-Powerfuq ....162-226-381 -410 Dry CFM
•
Indoor
Adapter(MAC-399117) 144-202-350-367 Wet CFM
•M- Contact of Adapter
Interface(MAC-397117) Heating(Lo-Med-Hi-Powerful) ....166-240-399-420 Dry CFM
• Sound Pressure Level
Wired Remote Controller(PAR-21 MAA;Requires MAC-3971 F)
• Cooling(Lo-Med-Hi-Powerful).......22-33-43-45 dB(A)
Condensate Pump(S13100-230;23OV) Powerful)
•Replacement Platinum Deodorizing Filter(MAC-308FT) Heating(Lo-Med-Hi-Powerful).. .....22-33-43-44 d6(A)
•Replacement Anti-allergy Enzyme Filter(MAC-418FT;MERV 8)
Cooling" DIMENSIONS UNIT INCHES/MM
Rated Capacity... .... . . .... . ........ . . . ......12,000 Btu/h W 31-7/16/799
Minimum Capacity . .. .......... .. . .... . .. 2,800 Btu/h D 10-1/8/257
SEER..... ...... .. .. ..... . .. .. . .. ....... . .23.0 Btu/h/W
H 11-5/8/295
Total Input........ .... ......... .. .. ... .... .. .. .. . .930 W
Heating at 47°F` Weight ... :. .... .. .. .. ... .... . .. ........ . . .27 lbs. / 12 kg
Rated Capacity........ .. .. ..... .. ......... .. .13,600 Btu/h External Finish ... .. ................Munsell No. 1.0Y 9.2/0.2
Minimum Capacity . .... .. ... . ............. .....3,000 Btu/h Field Drainpipe Size O.D......... . ..... ..... . 5/8" / 15.88 mm
HSPF ............... .... ..... . .............10.6 Btu/h/W Remote Controller .. ..... ........ ... .. .. .. ... ....Wireless
Total Input........ ........ .................... ... . .950 W
Heating at 17°F" Outdoor Unit
Rated Capacity...... ...... .... ... .. .. . . .. .. .. .8,300 Btu/h Compressor . .. ... ... .. . .:: . . . DC Inverter-driven Twin Rotary
Rated Total Input ... .. ....... .. .. . ..... . .. .. ...... .800 W MCA... .. .. .. .... .... . .12 A
Maximum Capacity.... ...... .... ...13,600 Btu/h Fan Motor. . ... .. . ........ .. .. . .. . . ... ........ . 0.56 F.L.A.
Maximum Total Input .. ....... .... ... ... . ......... 1,780 W Sound Pressure Level
•Rating Conditions(Cooling)-Indoor.80•F(27•C)DB,671F(19•C)WB;Outdoor.95°17 Cooling . .... ... .... ........ . ... ... .... . ..... ..48 d6 A)
(35°C)DB,75^F(24^C)WB. Heating .. .... ... ........ ...49 dB A)
(Heating at47°F)-Indoor.70•F(21•C)DB,60°F(16•C)WB;Outdoor:47.17(80C)DB,43.17(6•C)WB.
(Heating at 17°17)-Indoor:70.17(21•C)DB,60•F(161C)WB;Outdoor 17•F(-8•C)DB,15•F(J9°C)WB.
Heating at 5°'F DIMENSIONS INCHES/MM
Maximum Capacity...... ..... .. .. . ..... .. .....12,507 Btu/h W 31-1/2/800
D 11-1/4/286
Electrical Requirements H 21-518/549
Power Supply........ ............208/230V, 1-Phase,60 Hz
Breaker Size........ .. ........... .. ... . ........... ..15 A Weight ... ........ .. .. ....... ... ..... . .. ...80 lbs. /36 kg
External Finish ................... ..Munsell No. 3.OY 7.8/ 1.1
Voltage Refrigerant Type.... .. .. ......... . .. ... ... ... .... .. R41 OA
9 Refrigerant Pipe Size O.D.
Indoor-Outdoor S1-S2 ..... .... ... ..... . ....AC 208/230V Gas Side .. .. . . . ...... ... .. ... .... . .. .. .. . 3/8"/9.52 mm
Indoor-Outdoor S2-S3 ..... ....... .. ... . .......DC 12-24V Liquid Side. .. . ..... ... ... .. ...... .... .... . 1/4"/6.35 mm
Wireless Remote Controller........ . ...... ....... .... DC Max.Refrigerant Pipe Length........ ...... .. .. ....65' / 20 m
OPERATING RANGE Max.Refrigerant Pipe Height Difference ... .... . . ....40' / 12 m
Connection Method ............. ... ... ... ... .... ....Flared
Indoor IntakeAlr Temp. Outdoor Intake Air Temp.
Madmum 90•F(32•C)DB,73•F(23•C)WB 115•F(46•C)DB
Cooling Minimum 67•F(19•C)DB,57•F(14•C)WB 14•F(-10•C)DB
Madmum 80•F(27•C)DB,67•F(19•C)WB 75•F(24•C)DB,65°17(18°C)WB
Heating Minimum 70•F(21•C)DB,60•F(16•C)WB -13°17(-25•C)DB,-15T(26°C)WB'• K K
"System cuts out at-18•F(-28•C)to avoid thermistor error,but recovers from cutout
operation and automatically restarts at-13•F(-25•C).
11 -_,�. .
MSZ-FE12NA Unit: inch
31-3/8 7/16 X 1 Oblong hole 7/16 X 13/16 Oblong hole
30-7/8 1/2
2-1/2 8-7/8 8-7/8 0
Installation plate
n
co
I I I d' Go
Lwalpial
d>
04
ao
-1/ 13-9/16
Indoo.unit _14
IT 2011/16
Air in Wall hole 2-9/16
N u;1
11
10-1/ F/4 Installation late
8
27-1/16 2-3/16 Pi in
0
r N
co
`O Drain hose
3-3/8
o,9!�
01-3/8 O.D 3-1 /16
c01/4 19-11/16 Flared connection e1/4 Alr outr03/8 16-15/16 Flared connection o3/8
Drain hose Insulation 01-1/8 0.0 Connected part 05/8 O.D
MUZ-FE12NA Unit: inch
15-3/4 Drain hole 01-5/8
Air in REQUIRED SPACE Basically open 4 inch or more
without any obstruction in front
g
and on both sides of the unit.
cq �
Air in rJ 0 + rn or 001e
47n°rte
�
Air out
7/8
/2--3/8-113116 6 Oval hole
F 8l0 e r
o o
0%mot �Oj9
handle 29/32 11-1/4
Open two sides of left,
right,or rear side.
ao
N N
M
Liquid pipe :1/4(flared)
M 11.29/32 Gas pipe :3/8(flared)
7 1511 19-11/16
31-1/2 2-23/32 6 23132
MITSUBISHI
ELECTRIC
HVAC Advanced Products Division
3400 Lawrenceville Suwanee Rd
n/STESuwanee,GA 30024
Tele:678-376-2900•Fax:800.889-9904
Toll Free:800-433-4822(#3)
www.mehvac.com
C SD-MSZ-FE12NA/MUZ-FEI2NA-200908 0 MITSUBISHI ELECTRIC/HVAC 2009 Specifications are subject to change without notice.
SOUND STRUCTURAL SOLUTIONS
E N G T N E E R
I
C.Anderson Homes& Development
Chris Anderson
Client 495 W Spruce St, Ste 3 F
Sequim, WA 983820 W /LPr'L
360-504-1198 phone
360-504-1199 fax
SSS#I s1411002
Project Plan CA-1548 X., -1
Identification 1 Story SFR SJA�
WAC 196-23-070
Section Engineering Calculations
1 Wind & Earthquake Design
2 Partial Framing Design
6628 212th Street SW,Suite 205 - Lynnwood,WA 98036 - Ph:425.778-1023 - Fax:206-260-7490
i y
WUSGSDesign Maps Summary Report
User-Specified Input
Building Code Reference Document ASCE 7-10 Standard
(which utilizes USGS hazard data available in 2008)
Site Coordinates 48.101190N, 123.41989°W
Site Soil Classification Site Class D - "Stiff Soil"
Risk Category I/II/III
5mi
5000m
=PE,13WIA TE R
AY ..
Cott Angeles
M Part Angslga
A
a
101V
� Fd
\ r X201 f @ NlaipQuest
USGS-Provided Output
SS = 1.602 g SMS = 1.602 g Sos = 1.068 g
Sl = 0.640 g SMl = 0.961 g Sol = 0.640 g
For information on how the SS and S1 values above have been calculated from probabilistic (risk-targeted) and
deterministic ground motions in the direction of maximum horizontal response, please return to the application and
select the"2009 NEHRP" building code reference document.
MCEft Response Spectrum Design Response Spectrum
1.37
1.70 1.16
1.53 0.99
1.36 6.89 i
1.15 0.77
OY 1.02 Cfi 6.66
An 0.95 0,55-
0,44-
0,51--
.550.440.51 0.33--
034-- 0,22--
0.17--
0.00
.220.17 0.00 0.00
1.60 0.20 0.40 0.60 0.80 1.06 1.20 1.40 1.60 1.90 2.60 0.06 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 1.90 2.00
Period,T(set) Period, T(sec)
For PGAM, TL, CRS, and CR1 values, please view the detailed report.
Although this information is a product of the U.S.Geological Survey,we provide no warranty,expressed or implied,as to the accuracy of
the data contained therein.This tool is not a substitute for technical subject-matter knowledge.
Section 1
Lateral Analysis
s1411002
Number of Diaphragms 1
Code 12 IBC 2012 International Building code & 2010 ASCE7
General Design Criteria
Design Loads Dead Live Snow Seismic
s Mass
Roof 15 25 15
Floor 10 40
10
Wall 10 10
Risk Category II
Wind Design Criteria
Wind Load Design Procedure 2010 Envelope Procedure
Basic Wind Speed 130 mph
Surface Roughness C
Wind Exposure Category C
Topographic Factor Kzt 1.00
Enclosure Classification Enclosed Building
Internal Pressure Coefficient +/- 0.18
Seismic Design Data
Seismic Load Design Procedure 2010 Equiv. Lateral Force Procedure
Seismic Design Category D
Mapped Saectral Accelerations, MSA
Short Period Acceleration Ss 1.602
1-Second Accelleration Sl 0.640
Long-Period Transition Period TL 6 sec.
Spectral response coefficient SDs 1.07
Spectral response coefficient SDI 0.64
Site Classification D
Seis. Force Resisting System Table ..2.2-1: A-13
Transverse Longitudinal
Response Modification Factor R 6.5 6.5
Seismic Response Coefficient Cs 0.164 0.164
Design Base Shear 10882 10882 lbs
Overstrength Factor no 2.5
141106 SSSlateral 140507s'1411002 Section 1 DC
Wind Loads Wind Loads Help
Ridge Elevation 15 ft
Eave Height 8.333 ft
Mean Roof Height, h 11.667 ft
Least Horizontal Dimension, LHD 49 ft
Transverse Direction Longitudinal Direction
B Dimension 60 ft B Dimension 49 ft
L Dimension 49 ft L Dimension 60 ft
End Zone, 2a 6 ft End Zone, 2a 6 ft
Wall Areas Transverse Direction (WW) Longitudinal Direction (WW)
Roof Pitch 6 :12 Roof Pitch 5 :12
LEVEL Wall Area Roof Area LEVEL Wall Area Roof Area
(sq ft) (Horiz Proj) (sq ft) (Horiz Proj)
1 343 sq ft 256 sq ft 1 314 sq ft 228 sq ft
Transverse Direction (LW) Longitudinal Direction (LW)
Roof Pitch 6 :12 Roof Pitch 5 :12
LEVEL Wall Area Roof Area LEVEL Wall Area Roof Area
(sq ft (Horiz Proj) (sq ft) (Horiz Proj)
1 343 sq ft 256 sq ft 1 314 sq ft 228 sq ft
Wind Variables
Basic Wind Speed,V 130 mph Topographic Factor,Kzt 1.00
Directionality Factor,Kd 0.85 Velocity Pres.Exp.Coeff.Kz 0.85'
Velocity Pressure,g� 31.26 psf
Main Wind Force Resisting System - Diaphragm Design Loads
2010 Envelope Procedure
Direction Transverse Longitudinal
SUM 11689 9854
Load Case 1 17
1 11689 9854
141106_SSSlateral 140507_s1411002 Section 1 WF(2)
Seismic Loads
Effective seismic wei ht at Story x
roof area(ft) floor area(ft) story height(ft) trans-wall(ft) lona-wall(ft) misc load trans-wX long-wX
Diaphragm 1 2607 0 7.75 150 200
(lbs) 39105 0 11625 15500 46855 44918
Mapped Spectral Accelerations
Ss 1.602 Fa 1.000 SDs 1.07
St 0.640 Fv 1.500 SDI 0.64
Seismic Design Category D
Seismic Use Group II
Seismic Importance Factor IE 1.00
Site Classification D
Response Modification Coefficient Diaphragm Trans CsLong Cs
1 6.5 0.16 6.5 0.16
2010 Eauiv. Lateral Force Procedure
Transverse Longitudinal
Seismic Response Coeff. Ct= 0.020 0.020
X= 0.75 0.75
T= 0.102 sec 0.102 sec
hn= 9 ft
TL= 6 sec
Transverse Longitudinal
Cs= 0.164 0.164 lbs EQ 12.8-2
(Maximum) CS= 0.968 0.968 lbs EQ 12.8-3/8.4
(Minimum) Cs= 0.047 0.047 lbs EQ 12.8-5
(Minimum) Cs= 0.010 0.010 lbs EQ 12.8-5
(Minimum) Cs= 0.049 0.049 lbs EQ 12.8-6
Transverse Longitudinal
Base Shear V= 10882 lbs 10882 lbs
141106 SSSlateral 140507s14111002 Section 1 EF
Vertical Distribution,Forces at each level 12.8.3
k= 1.00
Transverse Longitudinal
Diaphragm hX w, w.hXk C. wX w,,h"k I C,'.
1 1 8.75 46855 1409981.251 1.000 44918 1393028.1251 1.000
409981.25 393028.125
Diaphragm Transverse Longitudinal
1 1 10882 1 10882 jibs
141106 SSSlateral 140507s1411002 Section 1 EF
Allowable Stress Design Loads
2010 Envelope Procedure 2010 Equiv.Lateral Force Procedure
Wind Load Combination Seismic Load Combination
0.6D+0.6W+H (0.6-0.14SDS)D+0.7pQE+H
%of DL used in OT %of DL used in OT
60% 45%
Wind Design Loads Fx Seismic Design Loads,FX
p= 1.30 123.4.E
TransverseLon itudinal Transverse Longitudinal
Diaphragm Force(lbs) Force(lbs) Diaphragm Force(lbs) Force(lbs)
1 7014 5913 1 1 9903 9903
Principle of Mechanics-cont.
Where, v= shear per linear foot of shearwall F
w= width of shearwall D
h= height of shearwall
D= resisting dead load centered over shearwall (y=b
P= resisting dead load at end of shearwall
Shearwall calculations follow,where,
V. Total force in the diaphragm above story(x), pounds(lbs) h
% Percent of VX tributary to the shearwalls(SW)in the wall line
VDx Force from the diaphragm above that transfers to the SW's,lbs
VTx+1 Force from the SW's above that transfers to the SW's,lbs sum 110101N
VTx Total force in the SW's(VD,+VT,.,),lbs ABOUT 0011 t
L Total length of SW's(7-w), feet(ft)
V Linear force in the SW's(VTX/L),pounds per foot(plf) rll
VF Greater of v induced by wind or earthquake,ph
Max Tx Maximum uplift force of the SW's,lbs Free Body Diagram of a ShearWall
V, Greater of v in the sheathing induced by wind per 2306.4.1 or earthquake per 2305.3.4,plf
w Width of SW,ft
h Height of SW,ft
dr Tributary distance of roof(used to calculate D)along the width of the SW,ft
dna Tributary distance of roof(used to calculate P)adjacent to the width of the SW,ft
df Tributary distance of floor(used to calculate D)along the width of the SW,ft
dfa Tributary distance of floor(used to calculate P)adjacent to the width of the SW,ft
TWX-1 Wind uplift force of the SW above that transfers to the SW,lbs
Twx Wind uplift force of the SW,lbs
Tex., Earthquake uplift force of the SW above that transfars to the SW,lbs
Tex Earthquake uplift force of the SW,lbs
141106 SSSlateral 140507s1411002 Section 1 DL
Wall Line Story(x) Direction Sheathing SW Dimensions Trit-AM Dead Loads Wind Uplift Earthquake Uplift
Shear
1 1 Trans vs w h dr dra df dfa Twx+, Twx TeX+, Tex
WIND E-QUAKE 140 16.00 7.75 2 2 63 645
VTX+i 140 13.33 7.75 16 2 -691 1 79
VDx 2455 4106
VTX 2455 4106
v 84 140
Max Tx 63 645
L VF VS
29.33 140 140
Wall Line Story(x) Direction Sheathing SW Dimensions Tributary Dead Loads Wind Uplift Earthquake Uplift
Shear
2 1 Trans vs w h dr dra df dfa Twx+, Twx Tex,, Tex
WIND E-QUAKE 176 17.10 7.75 15 2 -616 177
VTX+, 176 5.50 7.75 2 2 720 1180
VD, 3507 4951 176 5.50 7.75 2 2 720 1180
VTx 3507 4951
V 125 176
Max Tx 720 1180
L VF Vs
28.10 176 176
Wall Line Story(x) Direction Sheathing SW Dimensions Tributary Dead Loads Wind Uplift Earthquake Uplift
Shear
3 1 Trans vs w h dr dra df dfa Twx+, Twx Tex+, Tex
WIND E-QUAKE 207 2.81 7.75 2 2 1289 1044
VTX+l 207 2.81 7.75 2 2 1 1289 1 1044
VD, 1052 845
VTX 1052 845
v 187 150
Max Tx 1289 1044
L VF Vs
5.63 187 207
I
1411 06SSSlateral 1140507s1411002 Section 1 FR
Wall Line Story(x) Direction Sheathing SW Dimensions Tributary Dead Loads Wind Uplift Earthquake Uplift
Shear
A 1 Long vs w h dr d. df df. Twx,, Twx TeX+f TeX
WIND E-QUAKE 55 14.00 7.75 2 2 -320 37
VTX+1 55 9.33 7.75 2 2 1 -169 1 150
V DX 1327 2817 55 27.67 7.75 2 2 -760 -294
VTX 1327 2817—
v 26 55
Max Tx 150
L VF VS
51.00 55 55
Wall Line Story(x) Direction Sheathing SW Dimensions Tributary Dead Loads Wind Uplift Earthquake Uplift
Shear
B 1 Long VS w h dr d. df df. Twx+j Twx Tex., Tex
WIND E-QUAKE 206 24.00 7.75 12 2 -996 134
VT..,
V Dx 2956 4951
VTX 2956 4951
v 123 206
Max TX 134
L VF vs
24.00 206 206
Wall Line Story(x) Direction Sheathing SW Dimensions Tributary Dead Loads Wind Uplift Earthquake Uplift
Shear
C 1 Long vs w h dr dna df df. Twx+j Twx Tex., Tex
WIND E-QUAKE 74 4.31 7.75 2 2 227 414
VTx+1 74 24.69 7.75 2 2 -431 -80
V Dx 1629 2134
VTX 1629 2134
v 56 74
Max Tx 227 414
L VF Vs
29.00 74 74
1411 06SSSlateral 140507s'1411002 Section 1 SS
Shear Transfer Connections
Fasteners and Spacing
H N Vf N (A Ln (n N N N N N (A
N %0 co N
1Q V- -1 t%0 M [t NN lLn 00 1.4 k0 M
M . i � 4 ,^(
� U
3 ^ - ^ _ ^ 2x Plates 3x Plates
^ u u -- u to u =
u Ln �J X X X X
C1 G1 N (0 M
Ln .
Y N = ~ O O
Q fa O 2 0 Ln V- m 00 m 0) ca , i m
Z C O N Q -- Q u Q u Q u
fa C 0 cu
Ln fl. Ln C fY0 fa ate.+ fa ate.+ fa 2
� E N E a CL $a � (° 'a ns �
W `�° N 2 ~ M in -- -- -- moo_
,-� Ln Ln
A 150 11 9 55 27 12 38 16 101 75 110
B 213 8 \ 39 19 8 27 11 57 53 77
265 6 \\M 31 15 6 21 9 42 42 62
332 5 ��\\` 25 12 5 17 7 31 34 49
350 4 N23 11 5 16 7 29 32 47 \ �
450 3 \\ 18 9 4 12 5 21 12 18
600 2 13 6 3 9 4 15 9 13
780 2 \\\ 10 5 2 7 3 11 � �\: `� � 17 26
900 1.5 "`\?"" 9 4 2 6 2 10 `'." 15 22
935 1.5 \ " 8 4 1 6 2 9 "'' \\` 14 21
1190 1.0 \\ 7 3 1 4 2 7 17
Shearwall Capacities from ANSI/AF&PA SDPWS-2008 Table 4.3A
o MINIMUM
m NOMINAL PANEL DF DF
3 THICKNESS Nail or Staple size @ 16" oc @ 24" oc
o �
R (inch)
6 240 7/16" 8d @ 6"oc 260 240 6
350 7/16" 8d @ 4"oc 380 350 4
450 7/16" 8d @ 3"oc 490 450 3
585 7/16" 8d @ 2"oc 640 585 2
700 7/16" BOTH SIDES 8d @ 4"oc 760 700 44
900 7/16" BOTH SIDES 8d @ Yoc 980 900 33
1170 7/16" BOTH SIDES 8d @ 2"oc 1280 1170 22
The above allowable capacities were reduced by 2 for 2. Shears are
ASD and are for Seismic loads. Allowable Wind loads permitted to
are 1.4 greater. This office decreases the wind be increased 3. G=0.43
sheathing shear, v s, demand by this factor rather to values [1-(0.5-0.43)]
shown for = 0.93
than using the increased capacity. That way, only one 15/32-inch
set of capacities is needed for simplicity. sheathing...
141106 SSSiateral 140507s1411002 Section 1 ST
Shear Transfer Notes
[1] TABLE 11N [pg97 NDS] Z=89 lbs for a 16d box nail (D=0.135) in Hem-Fir G=0.43 and
multiplied by the load duration factor TABLE 10.3.1 [pg58 NDS] for wind/earthquake which is
CD=1.6 found in TABLE 2.3.2 [pg9 NDS]
[2] Value from note 1 then multiplied by the Toe-Nail Factor SECTION 11.5.4 [pg78 NDS] for
nominal lateral design values Ctn=0.83
[3] the A35 is used in loading condition 4 in an F1 direction of load according to Simpson
designations for SPF/HF Lateral(133/160) Z=450 lbs [pg146 C-2005]
[4]
[5] for SPSF/HF Lateral(133/160)Z=130 lbs [pg142 C-2005]
[6] the H1 is used in an F1 loading according to Simpson designations for SPF/HF
Lateral(133/160) Z=415 lbs [pg142 C-2005]
[7] the DTC is used in an F2 loading according to Simpson designations for SPF/HF
Lateral(133/160) Z=210 lbs [pg112 C-2005]
[8] TABLE 11E [pg85 NDS] Z=570 lbs for a 1/2" diameter bolt in 1-1/2" side member of Hem-Fir
G=0.43 and multiplied by the load duration factor TABLE 10.3.1 [pg58 NDS] for wind/earthquake
which is CD=1.6 found in TABLE 2.3.2 [pg9 NDS] Sill plates resisting a design load greater than
350 plf shall not be less than a 3-inch nominal member. Exception: With design load less than
600plf the sill plate is permitted to be a 2-inch nominal member if the sill plate is anchored by
two times the number of bolts requiredby design.
[9]TABLE 11E [pg85 NDS] Z=830 lbs for a 5/8" diameter bolt in 1-1/2" side member of Hem-Fir
G=0.43 and multiplied by the load duration factor TABLE 10.3.1 [pg58 NDS] for wind/earthquake
which is CD=1.6 found in TABLE 2.3.2 [pg9 NDS] Sill plates resisting a design load greater than
350 plf shall not be less than a 3-inch nominal member. Exception: With design load less than
600plf the sill plate is permitted to be a 2-inch nominal member if the sill plate is anchored by
two times the number of bolts requiredby design.
[10]TABLE 11E [pg85 NDS] Z=700 lbs for a 1/2" diameter bolt in 2-1/2" side member of Hem-Fir
G=0.43 and multiplied by the load duration factor TABLE 10.3.'1 [;pg58 NDS] for wind/earthquake
which is CD=1.6 found in TABLE 2.3.2 [pg9 NDS]
[11]TABLE 11E [pg85 NDS] Z=1040 lbs for a 5/8" diameter bolt in 2-1j2" side member of Hem-
Fir G=0.43 and multiplied by the load duration factor TABLE 10.3.1 [pg58 NDS] for
wind/earthquake which is CD=1.6 found in TABLE 2.3.2 [pg9 NDS]
141106 SSSlateral 140507s1411002 Section 1 ST
Horizontal Diaphragm Calculations
ANSI/AF&PA SDPWS-2008 Unblocked DF Unblocked HF
Table 4.2C
Panel Thickness Nails Case 1 All other Case 1 All other
Roof Diaphragm 7/16" 8d 230 170 213.9 158.1
Floor Diaphragm 1 23/32" (19/32") 10d 285 215 265.05 199.95
The minimum depth of horizontal diaphragm required to
provide shear capacity for SEISMIC forces
The minimum depth of horizontal diaphragm required to
provide shear capacity for WIND forces
Specify Shear Shear
Middle Roof or Shear a Stress Stress
Line Story Wind Seismic or end Floor Case Cap' Length wind Seis
1 1 2,455 4,106 E R All other 158.1 15.5 26.0
2.1 3,507 4,951 M R All other 158.1 11.1 15.7
31 1,052 845 E R All other 158.1 6.7 5.3
A 1 1,327 2,817 E R All other 158.1 8.4 17.8
B 1 2,956 4,951 E R All other 158.1 18.7 31.3
C 1 1,629 2,134 E R All other 1 158.1 10.3 13.5
1411 06SSSlateral 140507s1411002 Section 1 HD
Shear Wall Summary
Bio Bio
a -2C/)
Width SW VF Stressed vs Stressed Uplift W Uplift E Holdown Notes
iD 1 1 29.33 A 6 140 93% 140 58%
2 1 28.10 B 6 176 83% 176 7'% 1180 HUD2 at 5.5'walls
3 1 5.63 B 6 187 88% 207 86% 1289 1044 HDU2
A 1 51.00 A 6 55 37% 55 23%
B 1 24.00 B 6 206 97% 206 86%
C 1 29.00 A 6 74 49% 74 31%
y _ draw attention to the fact that 80% demand (corresponding to a 125% capacity) has
Gray 5cated Areas
F� � S been specified to address horizontal irregularities.
141106 SSSlateral 1140507s1411002 Section 1 SW
WOOC� Be1t11 File=\\ServersssUobs1s141s1411\$14110-2\W01411-11141106-1.EC6
ENERCALC,INC.1983-2014,Build:6.14.9.18,Ver:6.14.9.18
Description: 1-1
CODE REFERENCES
Calculations per NDS 2012, IBC 2012, CBC 2013,ASCE 7-10
Load Combination Set:ASCE 7-10
Material Properties
Analysis Method: Allowable Stress Design Fb-Tension 875.0 psi E:Modulus of Elasticity
Load Combination ASCE 7-10 Fb-Compr 875.0 psi Ebend-xx 1,300.0 ksi
Fc-Prll 600.0 psi Eminbend-xx 470.0 ksi
Wood Species : Douglas Fir-Larch Fc-Perp 625.0 psi
Wood Grade :No.2 Fv 170.0 psi
Ft 425.0 psi Density 32.210 pcf
Beam Bracing : Beam is Fully Braced against lateral-torsion buckling
D 0 2175 S 0 3625
t
i yr
6x8
Span=5.0 ft
Applied Loads Service loads entered.Load Factors will be applied for calculations.
Uniform Load: D=0.0150, S=0.0250 ksf, Tributary Width=14.50 ft,(ROOF)
DESIGN SUMMARY
Maximum Bending Stress Ratio = 0.419: 1 Maximum Shear Stress Ratio = 0.270 : 1
Section used for this span 6x8 Section used for this span 6x8
fb:Actual 421.82 psi fv:Actual 52.73 psi
FB:Allowable 1,006.25 psi Fv:Allowable 195.50 psi
Load Combination +D+S Load Combination +D+S
Location of maximum on span = 2.500ft Location of maximum on span = 0.000 ft
Span#where maximum occurs = Span#1 Span#where maximum occurs = Span#1
Maximum Deflection
Max Downward L+Lr+S Deflection 0.020 in Ratio= 2941
Max Upward L+Lr+S Deflection 0.000 in Ratio= 0<360
Max Downward Total Deflection 0.033 in Ratio= 18: 3
Max Upward Total Deflection 0.000 in Ratio= 0<240
......................... .. ...................................._........................_._._._._.
Overall Maximum Deflections
Load Combination Span Max.""Defl Location in Span Load Combination Max."+'Defl Location in Span
+D+S 1 0.0326 2.518 0.0000 0.000
Vertical Reactions Support notation:Far left is#1 Values in KIPS
Load Combination Support 1 Support 2
Overall MAXimum 1.450 1.450
Overall MINimum 0.326 0.326
D Only 0.544 0.544
+D+L 0.544 0.544
+D+Lr 0.544 0.544
+D+S 1.450 1.450
+D+0.750Lr+0.750L 0.544 0.544
+D+0.750L+0.750S 1.223 1.223
+D+0.60W 0.544 0.544
Section 2
Wood Beam File=\1ServeAsssWobs1s141s14111614110-21W01411-1\141106-1.EC6
ENERCALC,INC.1983-2014,Build:6.14.9.18,Ver.6.14.9.18
Description
Vertical Reactions Support notatic,;:=ar left is#1 Values in KIPS
Load Combination Support 1 Support 2
+D+0.70E 0.544 0.544
+D+0.750Lr+0.750L+0.450W 0.544 0.544
+D+0.750L+0.750S+0.450W 1.223 1.223
+D+0.750L+0.750S+0.5250E 1.223 1.223
+0.60D+0.60W 0.326 0.326
+0.60D+0.70E 0.326 0.326
D Only 0.544 0.544
Lr Only
L Only
S Only 0.906 0.906
W Only
E Only
H Only
Section 2
Wood Beam File=1\Serverlsss\Jobs1s141s14111S14110-�21W01411--11141106-1.EC6
ENERCALC,INC.1983-2014,Build:6.14.9.18,Ver.6.14.9.18
MINEMEEMo r s o
Description; 1-2
CODE REFERENCES
Calculations per NDS 2012, IBC 2012, CBC 2013,ASCE 7-10
Load Combination Set:ASCE 7-10
Material Properties
Analysis Method: Allowable Stress Design Fb-Tension 875.0 psi E:Modulus of Elasticity
Load Combination ASCE 7-10 Fb-Compr 875.0 psi Ebend-xx 1,300.0 ksi
Fc-Prll 600.0 psi Eminbend-xx 470.0 ksi
Wood Species : Douglas Fir-Larch Fc-Perp 625.0 psi
Wood Grade ;No.2 Fv 170.0 psi
Ft 425.0 psi Density 32.210 pcf
Beam Bracing : Beam is Fully Braced against lateral-torsion buckling
_........ D 0.03 S 0.05
i
f
1
1
6X8
i
Span=8.0 ft
Applied Loads Service loads entered. Load Factors will be applied for calculations.
Uniform Load: D=0.0150, S=0.0250 ksf, Tributary Width=2.0 ft,(ROOF)
DESIGN SUMMARY
;Maximum Bending Stress Ratio = 0.14±3 1 Maximum Shear Stress Ratio �= 0.060 : 1
Section used for this span 6x8 Section used for this span 6x8
fb:Actual 148.95 psi fv:Actual 11.64 psi
FB:Allowable 1,006.25 psi Fv:Allowable 195.50 psi
Load Combination +D+S Load Combination +D+S
Location of maximum on span = 4.000ft Location of maximum on span = 0.000ft
Span#where maximum occurs = Span#1 Span#where maximum occurs = Span#1
Maximum Deflection
Max Downward L+Lr+S Deflection 0.018 in Ratio= 52. 6
Max Upward L+Lr+S Deflection 0.000 in Ratio= 0<360
Max Downward Total Deflection 0.030 in Ratio= 3254
Max Upward Total Deflection 0.000 in Ratio= 0<240
i
...............................
i
Overall Maximum Deflections
Load Combination Span Max.""Defl Location in Span Load Combination Max."+"Defl Location in Span
+D+S 1 0.0295 4.029 0.0000 0.000
Vertical Reactions Support notation:Far left is#1 Values in KIPS
Load Combination Support 1 Support 2
Overall MAXimum 0.320 0.320
Overall MINimum 0.072 0.072
D Only 0.120 0.120
+D+L 0.120 0.120
+D+Lr 0.120 0.120
+D+S 0.320 0.320
+D+0.750Lr+0.750L 0.120 0.120
+D+0.750L+0.750S 0.270 0.270
+D+0.60W 0.120 0.120
Section 2
Wood Beam File=\\Serverlsss\Jobs1s141s14111514110-21W01411-11141106-1.EC6
ENERCALC,INC.1983-2014,Build:6.14.9.18,Ver:6.14.9.18
s r
Description: 1-2
Vertical Reactions Support notation:Far left is#1 Values in KIPS
Load Combination Support 1 Support 2
+D+0.70E 0.120 0.120
+D+0.750Lr+0.750L+0.450W 0.120 0.120
+D+0.750L+0.750S+0.450W 0.270 0.270
+D+0.750L+0.750S+0.5250E 0.270 0.270
+0.60D+0.60W 0.072 0.072
+0.60D+0.70E 0.072 0.072
D Only 0.120 0.120
Lr Only
L Only
S Only 0.200 0.200
W Only
E Only
H Only
Section 2
VIIOOd Beat11 File=\kServeftss\Jobs1s141s141104110-200141 1�-11141106-1.EC6
ENERCALC,INC.1983-2014,Build:6.14.9.18,Ver:6.14.9.18
Description: 1-3
CODE REFERENCES
Calculations per NDS 2012, IBC 2012, CBC 2013,ASCE 7-10
Load Combination Set:ASCE 7-10
Material Properties
Analysis Method: Allowable Stress Design Fb-Tension 900.0 psi E:Modulus of Elasticity
Load Combination ASCE?-10 Fb-Compr 900.0 psi Ebend-xx 1,600.0ksi
Fc-Prll 1,350.0 psi Eminbend-xx 580.0 ksi
Wood Species : Douglas Fir-Larch Fc-Perp 625.0 psi
Wood Grade :No.2 Fv 180.0 psi
Ft 575.0 psi Density 32.210pcf
Beam Bracing : Beam is Fully Braced against lateral-torsion buckling
_..._............
D 0.03 S 0.05
Mpm
F gg
2
4x12
i
i
Span=16.50 ft
f
Applied Loads Service loads entered. Load Factors will be applied for calculations.
Uniform Load: D=0.0150, S=0.0250 ksf, Tributary Width=2.0 ft,(ROOF)
DESIGNSUMMARY
:Maximum Bending Stress Ratio = 0.389. 1 Maximum Shear Stress Ratio = 0.121 : 1
Section used for this span 4x12 Section used for this span 4x12
fb:Actual = 442.51 psi fv:Actual = 25.14 psi
FB:Allowable 1,138.50 psi Fv:Allowable = 207.00 psi
Load Combination +D+S Load Combination +D+S
Location of maximum on span = 8.250ft Location of maximum on span = 0.000ft
Span#where maximum occurs = Span#1 Span#where maximum occurs = Span#1
Maximum Deflection
Max Downward L+Lr+S Deflection 0.126 in Ratio= 1568
Max Upward L+Lr+S Deflection 0.000 in Ratio= 0<360
Max Downward Total Deflection 0.202 in Ratio= 980 j
Max Upward Total Deflection 0.000 in Ratio= 0<240 `
Overall Maximum Deflections
Load Combination Span Max.""Defl Location in Span Load Combination Max."+"Defl Location in Span
+D+S 1 0.2020 8.310 0.0000 0.000
Vertical Reactions Support notation:Far left is#1 Values in KIPS
Load Combination Support 1 Support 2
Overall MAXimum 0.660 0.660
Overall MINimum 0.149 0.149
D Only 0.248 0.248
+D+L 0.248 0.248
+D+Lr 0.248 0.248
+D+S 0.660 0.660
+D-4750Lr+0.750L 0.248 0.248
+D+0.750L+0.750S 0.557 0.557
+D+0.60W 0.248 0.248
Section 2
Wood B@1111 File='11ServeftssWobsls141s14111514110-�2\W01411-11141106-1.EC6
ENERCALC,INC.1983-2014,Build:6.14.9.18,Ver:6.14.9:18
Description: 1-3
Vertical Reactions Support notation:Far left is#1 Values in KIPS
Load Combination Support 1 Support 2
+D+0.70E 0.248 0.248
+D+0.750Lr+0.750L+0.45OW 0.248 0.248
+D+0.750L+0.750S+0.450W 0.557 0.557
+D+0.750L+0.750S+0.5250E 0.557 0.557
+0.60D+0.60W 0.149 0.149
+0.60D+0.70E 0.149 0.149
D Only 0.248 0.248
Lr Only
L Only
S Only 0.413 0.413
W Only
E Only
H Only
Section 2
1
WOOCI' Bean1 File=llServerlsssWobs1s141s14111S14110-21W01411-�11141106-1.EC6
ENERCALC,INC.1983-2014,Build:6.14.9.18,Ver:6.14.9.18
e.ee.. • e ® a}
Description: 1-4
CODE REFERENCES
Calculations per NDS 2012, IBC 2012, CBC 2013,ASCE 7-10
Load Combination Set:ASCE 7-10
Material Properties
Analysis Method: Allowable Stress Design Fb-Tension 900.0 psi E:Modulus of Elasticity
Load Combination ASCE 7-10 Fb-Compr 900.0 psi Ebend-xx 1,600.0 ksi
Fc-Pdl 1,350.0 psi Eminbend-xx 580.0 ksi
Wood Species : Douglas Fir-Larch Fc-Perp 625.0 psi
Wood Grade ;No.2 Fv 180.0 psi
Ft 575.0 psi Density 32.210 pcf
Beam Bracing : Beam is Fully Braced against lateral-torsion buckling
D 0.16875 S 0.28125
W,
r
i
i
i
4X12
1
-- ----- Span=10.0 ft --
Applied Loads Service loads entered. Load Factors will be applied for calculations.
Uniform Load: D=0.0150, S=0.0250 ksf, Tributary Width=11.250 ft,(ROOF;
DES/GN SUMMARY _ ®'
Maximum Bending Stress Ratio = 0.8031 Maximum Shear Stress Ratio = 0.414 : 1
Section used for this span 4x12 Section used for this span 4x12
fb:Actual = 914.29 psi fv:Actual 85.71 psi
FIB:Allowable 1,138.50 psi Fv:Allowable = 207.00 psi
Load Combination +D+S Load Combination +D+S
Location of maximum on span = 5.000ft Location of maximum on span = 0.000ft
Span#where maximum occurs = Span#1 S.)a:i#where maximum occurs = Span#1
Maximum Deflection
Max Downward L+Lr+S Deflection 0.096 in Ratio= 1252
Max Upward L+Lr+S Deflection 0.000 in Ratio= 0<360
Max Downward Total Deflection 0.153 in Ratio= 782
Max Upward Total Deflection 0.000 in Ratio= 0<240
Overall Maximum Deflections
Load Combination Span Max.""Defl Location in Span Load Combination Max."+"Defl Location in Span
+D+S 1 0.1533 5.036 0.0000 0.000
Vertical Reactions Support notation:Far left is#1 Values in KIPS
Load Combination Support 1 Support 2
Overall MAXimum 2.250 2.250
Overall MINimum 0.506 0.506
D Only 0.844 0.844
+D+L 0.844 0.844
+D+Lr 0.844 0.844
+D+S 2.250 2.250
+D+0.750Lr+0.750L 0.844 0.844
+D+0.750L+0.750S 1.898 1.898
+D+0.60W 0.844 0.844
Section 2
Wood Beam File=\1ServersssWobsls141s14111514110-21W01411-11141106-1.EC6
ENERCALC,INC.1983-2014,Build:6.14.9.18,Ver:6.14.9.18
MR-MIGMIMMI • r e
Description: 1-4
Vertical Reactions Support notation:Far left is#1 Values in KIPS
Load Combination Support 1 Support 2
+D+0.70E 0.844 0.844
+0+0.750Lr+0.750L+0.450W 0.844 0.844
+D+0.750L+0.750S+0.450W 1.898 1.898
+D+0.750L+0.750S+0.5250E 1.898 1.898
+0.60D+0.60W 0.506 0.506
+0.60D+0.70E 0.506 0.506
D Only 0.844 0.844
Lr Only
L Only
S Only 1.406 1.406
W Only
E Only
H Only
Section 2
Wood BeamFile=1\Server\sss\Jobs\sl41sl4ll\S14110-�21W01411--1\141106-1.EC6
ENERCALC,INC.1983-2014,Build:6.14.9.18,Ver.6.14.9.18
TOM o 0
Description: 1-5
CODE REFERENCES
Calculations per NDS 2012, IBC 2012, CBC 2013,ASCE 7-10
Load Combination Set:ASCE 7-10
Material Properties
Analysis Method: Allowable Stress Design Fb-Tension 900.0 psi E:Modulus of Elasticity
Load Combination ASCE 7-10 Fb-Compr 900.0 psi Ebend-xx 1,600.0 ksi
Fc-Prll 1,350.0 psi Eminbend-xx 580.0 ksi
Wood Species : Douglas Fir-Larch Fc-Perp 625.0 psi
Wood Grade :No.2 Fv 180.0 psi
Ft 575.0 psi Density 32.210pcf
Beam Bracing : Beam is Fully Braced against lateral-torsion buckling
D 0.05 0
D 0.03 5 0.05
` tAoil
4x12
I
Span=19.330 ft
Applied Loads Service loads entered. Load Factors will be applied for calculations.
Uniform Load: D=0.0150, S=0.0250 ksf, Tributary Width=2.0 ft,(ROOF)
Varyinq Uniform Load: D(S,E)=0.050->0.0 k/ft,Extent=0.0 »19.330 ft, Trib Width=1.0 f
DESIGN SUMMARY
_.____..__.._.._....___._.___......_.._.____..____...__....._..._.._..__._____...........__.... ... __..... _.._.__.._.__....__...._...._......._...._...._.._........_..__..___._...._......_....._..._.....__..__....__.............._............_............_...._......._...._........__......
Maximum Bending Stress Ratio = 0.701: 1 Maximum Shear Stress Ratio = 0.202 : 1
Section used for this span 4x12 Section used for this span 4x12
fb:Actual = 798.36 psi fv:Actual 41.73 psi
FIB:Allowable 1,138.50 psi Fv:Allowable = 207.00 psi
Load Combination +D+S Lad Combination +D+S
Location of maximum on span = 9.312ft Location of maximum on span = 0.000ft
Span#where maximum occurs = Span#1 Span#where maximum occurs = Span#1
Maximum Deflection
Max Downward L+Lr+S Deflection 0.238 in Ratio= 975
Max Upward L+Lr+S Deflection 0.000 in Ratio= 0<360
Max Downward Total Deflection 0.499 in Ratio= 464
Max Upward Total Deflection 0.000 in Ratio= 0<240
i
Overall Maximum Deflections
Load Combination Span Max.%"Def! Location in Span Load Combination Max."+"Defl Location in Span
+D+S 1 0.4994 9.594 0.0000 0.000
Vertical Reactions Support notation:Far left is#1 Values in KIPS
Load Combination Support 1 Support 2
Overall MAXimum 1.095 0.934
Overall MINimum 0.367 0.271
D Only 0.612 0.451
+D+L 0.612 0.451
+D+Lr 0.612 0.451
+D+S 1.095 0.934
+D+0.750Lr+0.750L 0.612 0.451
+D+0.750L+0.750S 0.975 0.813
Section 2
Wood Beam File NServer\sssUobs\s14\s1411\514110--2\W01411--1\141106-1EC6
ENERCALC,INC.1983-2014,Build:6:14.9.1�Ver:6.14W.1�8lm
Description: 1-5
Vertical Reactions Support notation:Far left is#1 Values in KIPS
Load Combination Support 1 Support 2
+D+0.60W 0.612 0.451
+D+0.70E 0.612 0.451
+D+0.750Lr+0.750L+0.450W 0.612 0.451
+D+0.750L+0.750S+0.450W 0.975 0.813
+D+0.750L+0.750S+0.5250E 0.975 0.813
+0.60D+0.60W 0.367 0.271
+0.60D+0.70E 0.367 0.271
D Only 0.612 0.451
Lr Only
L Only
S Only 0.483 0.483
W Only
E Only
H Only
Section 2