117 E 3rd Street
PREPARED 12/21/16, 8:50:14 INSPECTION TICKET PAGE 3
CITY OF PORT ANGELES INSPECTOR: JAMES LIERLY DATE 12/21/16
------------------------------------------------------------------------------------------------
ADDRESS . : 117 E 3RD ST SUBDIV:
CONTRACTOR SOUND CONSTRUCTION PHONE (360) 461-9912
OWNER DEREK / JAQUELINE MEDINA PHONE (360) 461-9912
PARCEL 06-30-00-0-0-5455-0000-
APPL NUMBER: 16-00000705 RES REMODEL
------------------------------------------------------------------------------------------------
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
BL99 03 12/21/16L BLDG FINAL
December 21, 2016 8:18:09 AM jlierly.
Chad 461-9912
-------------------------------------- COMMENTS AND NOTES ----------
PREPARED 12/21/16, 8:50:14 INSPECTION TICKET PAGE 2
CITY OF PORT ANGELES INSPECTOR: JAMES LIERLY DATE 12/21/16
ADDRESS . : 117 E 3RD ST SUBDIV:
CONTRACTOR SOUND CONSTRUCTION PHONE (360) 461-9912
OWNER : DEREK / JAQUELINE MEDINA PHONE (360) 461-9912
PARCEL : 06-30-00-0-0-5455-0000-
APPL NUMBER: 16-00000705 RES REMODEL
------------------------------------------------------------------------------------------------
PERMIT: BPC 00 BUILDING PERMIT - COMMERCIAL
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
—----------------------------------------- ------------------—---------------------------
BFF 01 7/11/16 JLL BLDG FLOOR FRAMING
7/11/16 AP July 11, 2016 10:22:39 AM jlierly.
Chad 461-9916
July 11, 2016 4:37:27 PM jlierly.
BL3 01 7/26/16 JLL BLDG FRAMING
7/26/16 DA July 26, 2016 8:24:19 AM jlierly.
Chad 461-9912
July 26, 2016 4:10:53 PM jlierly.
Electrical and plumbing rough in required before frame can
be approved. JLL
BL3 02 8/11/16 JLL BLDG FRAMING
8/11/16 DA August 11, 2016 9:07:56 AM jlierly.
August 11, 2016 4:28:36 PM jlierly.
Electrical rough in required / Hangers on 2nd flr ceiling
joist / Burnt or rotten ceiling joist need to be replaced/
nail hangers not supported by top plate / Plumbing vent 2nd
flr will need to be protected or moved into attic space /
jll
BL3 04 8/12/16 JLL BLDG FRAMING
9/01/16 AP August 19, 2016 8:43:42 AM jlierly.
August 19, 2016 8:47:35 AM jlierly.
September 1, 2016 9:52:04 AM jlierly.
BL3 03 8/15/16 JLL BLDG FRAMING
8/15/16 DA August 15, 2016 9:22:24 AM jlierly.
chad
August 15, 2016 5:03:10 PM jlierly.
Electrical inspection has not been approved. Framing
inspection would pass otherwise. Call for frame and
insulation once elec has been approved/ill
BLWS 01 11/09/16 JLL BLDG INSULATION WALL/FLOOR
11/09/16 AP November 9, 2016 10:07:16 AM jlierly.
November 9, 2016 10:08:40 AM jlierly.
BL99 01 11/09/16 JLL BLDG FINAL
11/10/16 DA November 9, 2016 10:10:34 AM jlierly.
Chad 461-9912
November 10, 2016 8:48:22 AM jlierly.
Soil reqd to slope away from fnd/ strap w/h/ ex fan in
kitchen/ cc detectors in hall and at top of stairs/ missing
siding/ t&P termination needs a 90 deg elbow soldered on the
end of the drain./ jll
BL99 02 12/16/16 JLL BLDG FINAL
12/16/16 DA December 16, 2016 8:33:02 AM jlierly.
Chad 461-9912
December 16, 2016 3:41:59 PM jlierly.
3 items on list not complete, back fill around foundation
was completed on this inspection/jll
----------------------------------- CONTINUED ONTO NEXT PAGE -----------------------------------
CITY OF PORT ANGELES
DEPARTMENT OF COMMUNITY & ECONOMIC DEVELOPMENT- BUILDING DIVISION
321 EAST 5TH STREET, PORT ANGELES, WA 98362
a
Application Number . . . . . 16-00000705 Date 7/07/16
Application pin number . . . 518955
Property Address . . . . . . 117 E 3RD ST REPORT SALES TAX
ASSESSOR PARCEL NUMBER: 06-30-00-0-0-5455-0000-
Application type description RES REMODEL on your state excise tax form
Property
Name . . . . . . to the City of Port Angeles
Pro ert Use
Property Zoning . . . . . . . COMMUNITY SHOPPING DISTR (Location Code 0502)
Application valuation 30000
Application desc
residential remodel
----------------------------------------------------------------------------
Owner Contractor
.� ------------------------ ------------------------
DEREK / JAQUELINE MEDINA SOUND CONSTRDCTION
730 W 4TH ST 126 HANCOCK AVE
PORT ANGELES WA 98362 PORT ANGELES WA 98362
-----(360) 461-9912 -(360) 461-9912
-------------------------=------- -------------------------------
M Permit . . . . . . BUILDING PERMIT - COMMERCIAL
Additional desc REMODEL OFFICE
Permit Fee . . . . 468.25 Plan Check Fee 304.36
Issue Date . . . . 7/07/16 Valuation . . . . 30000
Expiration Date 1/03/17
Qty Unit Charge Per Extension
BASE FEE 417.75
5.00 10.1000 THOU BL-25,001-50K (10.10 PER K) 50.50
----------------------------------------------------------------------------
Permit . . . . PLUMBING PERMIT
Additional desc .
Permit Fee . . . . 78.00 Plan Check Fee .00
Issue Date 7/07/16 Valuation . . . . 0
Expiration Date 1/03/17
Qty Unit Charge Per Extension
BASE FEE 50.00
2.00 7.0000 EA PL-PLUMBING TRAP 14.00
1.00 7.0000 EA PL-WATER LINE . 7.00
1.00 7.0000 EA PL-DRAIN VENT PIPING 7.00
----------------------------------------------------------------------------
Special Notes and Comments
May 18, 2016 1:05:14 PM tamiot.
ELECTRICAL PERMIT REQUIRED.
OVERHEAD SERVICE CONDUCTORS REQUIRE 18FT CLEARANCE OVER
PARKING AREAS. INSTALLATION OF A UTILITY SERVICE POLE AT THE
NE PROPERTY CORNER AT THE EXPENSE OF THE OWNER.
May 18, 2016 1:09:20 PM tamiot.
June 21, 2016 4:43:00 PM tamiot.
Q June 23, 2016 10:42:48 AM rbe,ker.
With this being a commercial building, is there any plans of
installing a fire sprinkler system? A closed fire system
1 requires a double check valve assembly. An open fire system
Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes
null and void if work or construction authorized is not commenced within.180 days,if construction or work is suspended or abandoned
for a period of 180 days after the work has commenced, or if required inspections have not been requested within 180 days from the
last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions
of laws and ordinances governing this type of work will be complied iK whether specified herein or not. The granting of a permit does
not presume to give authority to violate or cancel the provisiqnsjaf any state or local law regulating construction or the performance of
construction.
CCS D /`1 (=1Cv S �C
Date`7!7 f Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder)
T:Forms/Building Division/Building Permit
BUILDING PERMIT INSPECTION RECORD
PLEASE PROVIDE MINIMUM 24-HOUR NOTICE FOR INSPECTIONS—
Building Inspections 417-4815 Electrical Inspections 417-4735
Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886
IT IS UNLAWFUL TO COVER,INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED.
POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE.
Inspection Type Date Accepted By Comments
FOUNDATION:
Footings
Stemwall
Foundation Drainage I Downspouts
Piers
Post Holes(Pole Bldgs.)
PLUMBING:
Under Floor/Slab
Rough-in
Water Line Meter to Bldg)
Gas Line a
Back Flow/Water
AIR SEAL:
Walls
Ceiling
FRAMING:
Joists/Girders/Under Floor
Shear Wall/Hold Downs
Walls/Roof/Ceiling
Drywall Interior Braced Panel Only)
T-Bar
INSULATION:
Slab
Wall/Floor/Ceiling
MECHANICAL:
Heat Pump/Fumace/FAU/Ducts
Rough-In
Gas Line
Wood Stove/Pellet/Chimney
Commercial Hood/Ducts
MANUFACTURED HOMES:
Footing/Slab
Blocking&Hold Downs
Skirting
PLANNING DEPT. Separate Permit#s SEPA:
Parkin /Lighting ESA:
Landscaping SHORELINE:
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE
Inspection Type _ Date Accepted By
Electrical 417-4735
Construction -R.W. PW I Engineering 417-4831
Fire 417-4653
Planning 417-4750
Building 417-4815
%�► CITY OF PORT ANGELES
�'�i DEPARTMENT OF COMMUNITY& ECONOMIC DEVELOPMENT- BUILDING DIVISION
321 EAST 5TH STREET, PORT ANGELES, WA 98362
Page 2
Application Number . . . . . 16-00000705 Date 7/07/16
Application pin number . . . 518955
--------------------------------- -------------------------- REPORT SALES TAX
Special Notes and Comments on your state excise tax form
does not require a backflow assembly.
If you have any questions, call Ron Becker at 417-4886, to the City of Port Angeles
fax:360-452-4972, or E-mail:rbecker@cityofpa.us (Location Code 0502)
May 31, 2016 2:54:18 PM permits.
approved
Public Works Utility Engineering has no requirements for
this plan review.
----------------------------------------------------------------------------
Other Fees . . . . . . . . . STATE SURCHARGE 4.50
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- -------=-- ----------
Permit Fee Total 546.25 546.25 .00 .00
Plan Check Total 304.36 304.36 .00 .00
Other Fee Total 4.;50 4.50 .00 .00
Grand Total 855.11 855.11 .00 .00
Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements.This permit becomes
null and void if work or construction authorized isnot commenced within 180 days,if construction or work is suspended or abandoned
fora period of 180 days after the work has commenced, or if required inspections have not been requested within 180 days from the
last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions
of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does
not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construction.
Date Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder)
T:Forms/Building Division/Building Permit
BUILDING PERMIT INSPECTION RECORD
— PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS—
Building Inspections 417-4815 Electrical Inspections 417-4735
Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886
IT IS UNLAWFUL TO COVER,INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED.
POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE.
Inspection Type Date Accepted By Comments
FOUNDATION:
Footings
Stemwall
Foundation Drainage/Downspouts
Piers
Post Holes(Pole Bldgs.)
PLUMBING:
Under Floor/Slab
Rough-In
Water Line Meter to Bldg)
Gas Line
Back Flow/Water
AIR SEAL:
Walls
Ceiling
FRAMING:
Joists/Girders/Under Floor
Shear Wall/Hold Downs
Walls/Roof/Ceiling
Drywall Interior Braced Panel Only)
T-Bar
INSULATION:
Slab
Wall/Floor/Ceiling
MECHANICAL:
Heat Pump/Furnace/FAU/Ducts
Rough-in
Gas Line
Wood Stove/Pellet/Chimney
Commercial Hood/Ducts
MANUFACTURED HOMES:
Footing/Slab
Blocking&Hold Downs
Skirting
PLANNING DEPT. Separate Permit#s SEPA:
Parkin /Lighting ESA:
Landscaping SHORELINE:
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE
Inspection Type _ Date Accepted By
Electrical 417-4735
Construction - R.W. PW I Engineering 417-4831
Fire 417-4653
Planning 417-4750
Building 417-4815
1
THE
ORT
C TP---':Y OFN,�NGELES" For City Use —
Permit# b
WASH 1 N G T O N , U . S. '�
/ Date Received:
321 E 51h Street I ate Approved I it
Port Angeles,WA 9836
P:360-417-4817 F:360-417-4711
Email:permits@cityoflaa.us BUILDING PERMIT PLICATION
Pro'ec_t Address: 3 j PO I2 /C5
Phone: 3 U 2 1 1'2-
Primary
2Prima Contact: G��►� 11Je 1(o,S fL Email: 2 KOS k ,zA ao ,Ga,
Name ve re / „ ^ e ,� Phone
Property Mailing !Address ` r Email
Owner //7 r'o. - 32
City PO '4 n e e-) `# State �R- Zip
Name S'OU/l orlSTfCiG�//"-L) Phone 9GO _�� 1 — 171 2
Contractor Address r��•/ Email C..Q h/Q�co�l� 14�� �►.eKss6o 0
Information cityfp r f �,� e �cS c✓ state zip �g3� ,
Contractor License# too/1 (' 7I`L C Exp.Date: J Ul
Legal Description: Zoning: Tax Parcel# Project lue: (materials and labor)
Ca 6 a =
Residential ❑ Commercial A Industrial ❑ Public ❑
Permit Demolition JDL Fire ❑ Repair g� Reroof(tear off/lay over) ❑
Classification For the following,fill out both pages of permit application:
(check New Construction ❑ Exterior Remodel ❑ Addition ❑ Tenant Improvement ❑
appropriate) Mechanical ❑ Plumbing ❑ Other Ja
Fire Sprinkler System Proposed Irrigation System Proposed or Proposed Bathrooms Proposed Bedrooms
or Existing? Yes ❑ No ❑ Existing? Yes ❑ No ❑
In addition to standard hard copy submittals please send a PDF copy of all Stormwater plans and Engineering to
w-ww.stormwater(&citvo a.us
Project Description d = f 6 C/
6' LX
Is project in a Flood Zone: Yes No❑ Flood Zone Type:
If in a Flood Zone,what is the value of the structure before proposed improvement? $
I have read and completed the application and know it to be true and correct.I am authorized to apply for
this permit and understand that it is my responsibility to determine what permits are required and to
obtain permits prior to work. I understand that plan review fees are not refundable after review has
occurred. I understand that I will forfeit review fees if I withdraw the application before the permit is
issued. I understand that if the permit is not picked up/issued within 18o days of submittal,the application
will be considered abandoned and the fees will be forfeited.
Date Print Name Signature
r Residential Structures
�• Existing Proposed Construction For Office Use
Area Descriptions(SQ'FT) Floor area Floor area $Value new area
Basement
First Floor
Second Floor
Covered Deck/Porch/Entry
Deck(over 30"or 2'd floor)
Garage
Carport
Other(describe)
Area Totals
Commercial Structures
Area Descriptions(SQ FT) Existing Proposed . Construction For Office Use
Floor area Floor area $Value new area
Existing Structure(s)
Proposed Addition
Tenant Improvement?
Other work(describe)
Site Area Totals
f
Lot/Site Coverage Calculations
Lot Size (sq ft) Lot Coverage(sq ft)foot print of %Lot Coverage(Total lot cov_lot size) Max Bldg Height ,(
all structures s ft
Site Coverage(Sq Ft of all impervious) %of Site Coverage(total site cov_lot size)
Mechanical Fixtures
Indicate how many of each type of fixture to be installed or relocated as part of this project.
Air Handler Size: # Haz/Non-Haz Piping Outlets:
Appliance Exhaust Fan # Heater(Suspended,Floor,Recessed wall) #
Boiler/Compressor Size: # Heating/Cooling appliance #
repair/alteration
Evaporative Cooler(attached,not # Pellet Stove/Wood-burning/Gas #
portable) Fireplace/Gas Stove/Gas Cook Stove/Misc.
Fuel Gas Piping #of Outlets: Ventilation Fan,single duct #
Furnace/Heat Pump/ Size: # Ventilation System #
Forced Air Unit
Plumbing Fixtures
Indicate how many of each type of fixture to be installed or relocated
Plumbing Traps # Water Heater #
Plumbing Vent piping # j Medical gas piping #of Outlets:
Water Line # ! Fuel gas piping #of Outlets:
Sewer Line # Industrial waste pretreatment
interceptor Grease Trap) Size
Other(describe):
T:\Forms\2015 CED Form Updates\Building&Permitting\BP\Building Permit 20150415.docx
Residential Structures
Existing Proposed Construction For Office Use
Area Descriptions(SQ FT) Floor area Floor area $Value new area
Basement
First Floor
Second Floor
Covered Deck/Porch/Entry
Deck(over 30"or a° floor)
Garage
Carport
Other(describe)
Area Totals
Commercial Structures
Area Descriptions(SQ FT) Existing Proposed . Construction For Office Use
Floor area Floor area $Value new area
Existing Structure(s)
Proposed Addition
Tenant Improvement?
Other work(describe)
Site Area Totals
- r
Lot/Site Coverage Calculations
Lot Size (sq ft) Lot Coverage(sq ft)foot print of %Lot Coverage(Total lot cov=lot size) Max Bldg Height
all structures sq ft
Site Coverage(Sq Ft of all impervious) %of Site Coverage(total site cov_lot size)
Mechanical Fixtures
Indicate how many of each type of fixture to be installed or relocated as part of this project.
Air Handler Size: # Haz/Non-Haz Piping Outlets:
Appliance Exhaust Fan # Heater(Suspended,Floor,Recessed wall) #
Boiler/Compressor Size: # Heating/Cooling appliance #
repair/alteration
Evaporative Cooler(attached,not # Pellet Stove/Wood-burning/Gas #
portable) Fireplace/Gas Stove/Gas Cook Stove/Misc.
Fuel Gas Piping #of Outlets: Ventilation Fan,single duct #
Furnace/Heat Pump/ Size: # Ventilation System #
Forced Air Unit
Plumbing Fixtures
Indicate how many of each type of fixture to be installed or relocated
Plumbing Traps # Water Heater #
Plumbing Vent piping # % Medical gas piping #of Outlets:
Water Line # I Fuel gas piping #of Outlets:
Sewer Line # Industrial waste pretreatment
interceptor Grease Trap) Size
Other(describe):
T:\Forms\2015 CED Form Updates\Building&Permitting\BP\Building Permit 20150415.docx
ALLEY
1
I
i
S
e�
A �.
v
, 1
j
l
} _ 10'x 0'PARKING 5 AGE5
a
i
l
IL
_N
W
R
I ao
I a ui
i
• I
I _
I.
I
I I
y I [J I
� I
I I I
t I I I I
I I
I �—
I
iL
LU
I I
w
W
v
Z w
O Cl
Q to
E.3RD 5T. SIDEWALK
PLOT PLAN 1 oe ® 10'
Small Project Drainage Plan for Parking Lots Less than 5000 SF
Provide a plan that shows how you will collect rainwater from hard surfaces. The conventional method
is to use a catch basin to collect the rain water and connect to the municipal stormwater system. Note
pipe location and elevations. This plan should also show how you will provide temporary control of rain
water and disturbed soil during construction.
An alternative to this method uses low impact development such as a rain garden,.permeable pavement
or swale as pretreatment to a dry well. This option will require a minimal effort from a design
professional. The following are details you can provide your design professional to meet applicable
requirements.
How-to Checklist to Install LID Infiltration Feature
1. Determine Soil Infiltration Abilities by Professional Engineer or Septic System Designer, Certified
• by Clallam County. For approved method descriptions see Ecology Stormwater Management
Manual for Western Washington 2005(SMMWW)Volume III,Section 3.3.6:
a. USDA Soil Textural Classification
b. ASTM Gradation Testing, based on D10 Size
c. In-situ Infiltration (Pilot Infiltration Test)
2. Size Infiltration Facility, Calculations stamped by Professional Engineer
a. Stormwater discharges shall match developed discharge durations to predeveloped
(existing land cover) discharge rates for the range of from 50%of the 2 year to the full
50-year peak flow(Urban Service Standards 5.04.07.03)This standard requirement is
waved for sites that will reliably infiltrate all the runoff from impervious surfaces and
converted pervious surfaces.
b. Runoff from parking lot must receive pretreatment before reaching infiltration facility
i. This could be by dispersion over a grassy area or through rain garden soil mix
(See SMMWW Volume III,Section 3.3.11 for other options)
3. Provide Plan that shows proposed drainage features (Plan does not have to be prepared by
Professional Engineer but must accurately reflect proposed work)
a. Temporary erosion and tracking control measures(such as silt fence,construction
entrance- use of existing hard surfaces such as a garage pad, paved driveway, etc.)
b. Location and Details of LID Infiltration Feature. Standard details from Volume III,
Chapter 3 of the current edition of the SMMWW may be provided with or referenced on
the plan.
c. Size, location, relative invert elevations, and cover of overflow pipe (if through curb line,
pipe size less than or equal to 3")
d. Maintenance schedule (what is needed,when, and by who). Guidance for maintenance
requirements can be found in Volume III, Chapter 3 of the current edition of the
Stormwater Management Manual for Western Washington.
The current edition of the Stormwater Management Manual for Western Washington is available on line
at: http://www.cityofpa.us/PDFs/Stormwater/StormwaterManualComplete.pdf
dv� �'
1....L`� <<2 �,C/��G�2r�- C-s ���i7�s Odd,
`•.
_.
a •
133 122 124 :
�R 131 2 ki� 104 ;'1 105 ,
,.
, 07111
127 '
02
,6 117 104 ��6i�n 123 127 112
do 06
C
d o
110 yS! �+►
73�. 106
126 12 116 b 129
3 v
122el118
120 s �
., of
114 �► 111 124 �
101
1 136
6, 1 110
132 � p
o' ' ,a1',S!) 1 _ ,�• °'`34� ` 119 .'� ,�V D �
108 208 �. If l .' I121 4 " 108
u
t
15 13 ,... va,,� 102
�
a• 214 ` 11
4
12
fo 218 N� ?� 112 18 130 Cr '
416, �v {�
r
110 0
105 , 202 i p
. 111
J �
104
s
117
125 205 v
105
220 215
ft N ," 217 .:
,2W
1� � '.vn �•�TV '0A - a).' Q� ��r - >oc �-�T r�^�r. '�
y .•. � 'x '� ` � fin.,. � �'
72i�� „��
110
c4` s 402 t;
223
r
408 ,
"J
. ! 412
i
• 418 ,
/ 403 210/'
e 112
118 .E;
112 ~►
217 � >
X
3..
s
202
121 k
r
4 s
220
Lu
C( Vu;" .
z ;
d °° °
34' = z 0
m W z
10'-4 1/2" T-0 1/2" 5'-l" 116 b w o o
2'- 0 2'-10" 2'-4" 2'-b" 5'
2'-4" b' = - —F—3' z
0 < <
]068 5029FX
LL cV
— -- c'f) -- m C(1
6060 3010L5 210305H
o -- UTILITY I S
825R 5896 82411R '-4"x 8'-0"
5
C14BATH
� � 4
CONFERENCE
= ROOM �� T-31/2" o y
I
� - 10'-0°x 12'-0° 4'-5 1/2" KITCHEN -
a � �
T-3"X 12'-5" V o
E 4
n ry' OFFICE r I m '
b'-4"X T-9"
Ll I IL
G
.36i I
W
-- ---- _.- — 'O 0
ry 5' 4'-9 1/2" 3'-3 1/2" = 19'-5 1/2" N m °-
ry I
2068 16"
N Z
I H
w
z
LOBBY i ry
o OFFICE 1b'-1"x 12'-7 LU
I
�3'-l"X 10'-1" Up I I °_° Z I I W
z O
I � �
W
U
J
2'-q 1/2" a' 4'-6"
13'-11 1/211—5 112" 5' 14'-4"
34'
FLOOR PLAN 1/4 = 1 ' LII 5AREA A'
�L
5TORAGE
11'-6"X 10'-1"
ry � DN
ae
5' -- - --- 24, 5,
I
I
I --
L _ _._ _ _. - 603085 - - - -- - - 603OL5 -..
— -- 34' -
LIVING AREA
643 50 FT
2ND FLOOR PLAN 1/4" = 1 '
I