PREPARED 8/07/15, 9:46:16 INSPECTION TICKET PAGE 2
CITY OF PORT ANGELES INSPECTOR: JAMES LIERLY DATE 8/07/15
---------------- ---
ADDRESS . : 1217 DUTCH DR SUBDIV:
CONTRACTOR DUTCH DRIVE DEVELOPMENT LLC PHONE (360) 565-6269
OWNER PA PARTNERS LLC PHONE (360) 303-8748
PARCEL 06-30-01-8-0-0130-0000-
APPL NUMBER: 15-00000343 RES NEW SFR
------------------------------------------------------------------------------------------------
PERMIT: BPR 00 BUILDING PERMIT - RESIDENTIAL
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
----—---------------------------------------—--------------------------—--------------------
BL1 01 4/30/15 JLL BLDG FOUNDATION FOOTING
4/30/15 AP April 30, 2015 8:27:36 AM jlierly.
reid moore
April 30, 2015 4:53:09 PM jlierly.
BL2 01 5/04/15 JLL BLDG FOUNDATION STEM WALL
5/04/15 AP May 4, 2015 10:01:25 AM jlierly.
reid 460-4561
May 4, 2015 4:08:28 PM jlierly.
BFF 01 5/18/15 JLL BLDG FLOOR FRAMING
5/18/15 AP May 18, 2015 9:51:36 AM jlierly.
Reid 460-4561
May 18, 2015 3:53:00 PM jlierly.
BLSH 01 6/03/15 JLL BLDG SHEATHING
6/03/15 AP June 3, 2015 8:49:54 AM jlierly.
reid
June 3, 2015 3:21:05 PM jlierly.
BAIR 01 6/24/15 PB BLDG AIR SEAL
6/24/15 AP June 24, 2015 8:44:57 AM pbarthol.
June 24, 2015 4:43:47 PM pbarthol.
BL3 01 6/24/15 PB BLDG FRAMING
6/24/15 AP June 24, 2015 8:44:34 AM pbarthol.
Todd 565-6269
June 24, 2015 4:43:47 PM pbarthol.
BLI 01 6/29/15 JLL BLDG INSULATION
7/21/15 AP June 29, 2015 9:32:15 AM jlierly.
July 21, 2015 2:11:30 PM jlierly.
BLDR 01 7/06/15 JLL BLDG DRYWALL IBWP
7/06/15 AP July 6, 2015 9:17:35 AM jlierly.
Larry
July 6, 2015 4:15:32 PM jlierly.
FFNL O1 8/04/15 KDD FIRE FINAL
8/04/15 AP August 4, 2015 11:32:07 AM kdubuc.
August 4, 2015 11:32:25 AM kdubuc.
BL99 01 8/07/15 AmOA BLDG FINAL
August 7, 2015 9:36:38 AM jlierly.
PERMIT: ME 00 MEI PERMIT
REQUESTEDAI SP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
--------------------------—----------—------
ME1 01 6/24/15 PB MECHANICAL ROUGH-IN
6/24/15 AP June 24, 2015 4:43:16 PM pbarthol.
June 24, 2015 4:43:47 PM pbarthol.
ME99 01 8/07/15 J 1� MECHANICAL FINAL
August 7, 2015 9:36:51 AM jlierly.
-------------------------------------------------------------------
PERMIT: PL 00 PLUMBIN PE IT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
----------------------------------- CONTINUED ONTO NEXT PAGE -----------------------------------
PREPARED 8/07/15, 9:46:16 INSPECTION TICKET PAGE 3
CITY OF PORT ANGELES INSPECTOR: JAMES LIERLY DATE 8/07/15
------------------------------------------------------------------------------------------------
ADDRESS . : 1217 DUTCH DR SUBDIV:
CONTRACTOR DUTCH DRIVE DEVELOPMENT LLC PHONE (360) 565-6269
OWNER PA PARTNERS LLC PHONE (360) 303-8748
PARCEL 06-30-01-8-0-0130-0000-
APPL NUMBER: 15-00000343 RES NEW SFR
------------------------------------------------------------------------------------------------
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
---------------------------— - --
PL6 01 5/15/15 JLL PLUMBING WATER SUPPLY
5/15/15 AP May 15, 2015 9:33:07 AM Jlierly.
danny
May 15, 2015 4:28:13 PM Jlierly.
PL2 01 6/23/15 JLL PLUMBING ROUGH-IN
7/21/15 AP June 23, 2015 9:07:45 AM jlierly.
460-5721
July 21, 2015 2:11:11 PM jlierly.
PL99 01 8/07/15 L PLUMBING FINAL
August 7, 2015 9:37:03 AM jlierly.
----------------------�-7 ---------- COMMENTS AND NOTES JL
CC CITY OF PORT ANGELES
DEPARTMENT OF COMMUNITY& ECONOMIC DEVELOPMENT- BUILDING DIVISION
321 EAST 5TH STREET, PORT ANGELES, WA 98362
Application Number . . . . . 15-00000343 Date 4/29/15
Application pin number . . . 231476
Property Address . . . . . . 1217 DUTCH DR
ASSESSOR PARCEL NUMBER: 06-30-01-8-0-0130-0000- REPORT SALES TAX W
Application type description RES NEW SFR
Subdivision Name . . . . . . on your state excise tax form
Property Use . . . to the City of Port Angeles
Property Zoning . . . . . . . RS9 RESDNTL SINGLE FAMILY
Application valuation . . . . 156169 (Location Code 0502)
----------------------------------------------------------------------------
Application desc
1609 sq ft 1 story sfr with attached garage
----------------------------------------------------------------------------
Owner Contractor
PA PARTNERS LLC DUTCH DRIVE DEVELOPMENT LLC
710 LARRABEE AVE 710 LARRABEE AVE
BELLINGHAM WA 98225 BELLINGHAM
(360) 303-8748 BELLINGHAM WA 98225
(360) 565-6269
----------------------------------------------------------------------------
Permit . . . . . . BUILDING PERMIT -RESIDENTIAL
Additional desc . . 1609 SQ FT SFR
Permit Fee . . . . 1339.45 Plan Check Fee 870.64
Issue Date . . . . 4/29/15. Valuation . . . . 156169
Expiration Date 10/26/15
v
Qty Unit Charge Per Extension
BASE FEE 1020.25 Q�
57.00 5.6000 THOU BL-100,001-500K (5.60 PER K) 319.20
-------------------------------------------------------
Permit . . . . . . MECHANICAL PERMIT
Additional desc . . SFR MECHANICAL
Permit Fee . . . . 171.20 Plan Check Fee .00
4 Issue Date . . . . 4/29/15 Valuation . . . 0
_\\ Expiration Date 10/26/15
Qty Unit Charge Per Extension
BASE FEE 50.00
1.00 14.8000 EA ME-FURN/HP/FAU < OR = 5 TON 14.80
3.00 7.2500 EA ME-VENT FAN (SINGLE-'DUCT) 21.75
1.00 10.6500 EA ME-HOOD/DUCT-MECH. EXHAUST 10.65
5.00 14.8000 EA ME-HEATER(SUSP/WALL/FLOOR-MTD) 74.00
J ----------------------------------- -
Permit . . . . . . PLUMBING .PERMIT
!� Additional desc SFR PLUMBING
Permit Fee 170.00 Plan Check Fee .00
!� Issue Date . . . . 4/29/15 Valuation 0
Expiration Date . . 10/26/15
Qty Unit Charge Per Extension
BASE FEE 50.00
9.00 7.0000 EA PL-PLUMBING TRAP 63.00
1.00 7.0000 EA PL-WATER LINE 7.00
Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes
null and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned
for a period of 180 days after the work has commenced, or if required inspections have not been requested within 180 days from the
last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions
of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does V
not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construction.
Y 'Z) &1IC �-
Date Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder)
T:Forms/Building Division/Building Permit
•E
BUILDING PERMIT INSPECTION RECORD
-- PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS —
Building Inspections 417-4815 Electrical Inspections 417-4735
Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886
IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED.
POST PERMIT IN CONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE.
Inspection Type Date Accepted By Comments
FOUNDATION:
Footings
Stemwall
Foundation Drainage/Downspouts
Piers
Post Holes(Pole Bldgs.)
PLUMBING:
Under Floor/Slab
Rough-In
Water Line Meter to Bldg)
Gas Line
Back Flow/Water FINAL Date Accepted b
AIR SEAL:
Walls
Ceiling
FRAMING:
Joists/Girders/Under Floor
Shear Wall/Hold Downs
Walls/Roof/Ceiling
Drywall Interior Braced Panel Only)
T-Bar
INSULATION:
Slab
Wall/Floor/Ceiling
MECHANICAL:
Heat Pum /Furnace/FAU/Ducts
Rough-in
Gas Line
Wood Stove/Pellet/Chimney
Commercial Hood/Ducts FINAL Date Accepted b
MANUFACTURED HOMES:
Footing/Slab
Blocking&Hold Downs
Skirting
PLANNING DEPT. Separate Permit#s SEPA:
Parkin /Lighting ESA:
Landscaping SHORELINE:
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE
Inspection Type Date Accepted By
Electrical 417-4735
Construction-R.W. PW I Engineering 417-4831
Fire 417-4653
Planning 417-4750
Building 417-4815
T:Forms/Building Division/Building Permit
CITY OF PORT ANGELES
DEPARTMENT OF COMMUNITY& ECONOMIC DEVELOPMENT- BUILDING DIVISION
_ 321 EAST 5TH STREET, PORT ANGELES,WA 98362
Page 2
Application Number . . . . . 15-00000343 Date 4/29/15
Application pin number . . . 231476
REPORT SALES TAX
Qty Unit Charge Per Extension our state excise tax form
4.00 7.0000 EA PL-DRAINon VENT PIPING 28.00 Y
1.00 15.0000 EA PL-SEWER LINE 15.00 to the City of Port Angeles
1.00 7.0000 PL-WATER HEATER 7.00
-- -- Location Code 0502)
Special Notes and Comments
April 8, 2015 8:10:17 AM rbecker.
For your lawn sprinkler system, you will need to install a
double check valve assembly. If your fire sprinkler system
is a closed system, you will need to install a double check
valve asssembly. If the fire system is an open system, you
do not need a backflow assembly.
If you have any questions call Ron Becker at 360-417-4886,
fax:360-452-4972, or E-mail: rbecker@cityofpa.us
Address numbers shall be plainly visible from the street.
Address numbers shall be a minimum of six inches high and be
of contrasting color from the background.
All homes in new subdivisions that are outside of the Fire
Department four-minute response area shall be equipped with
residential fire sprinkler systems that comply with the
International Fire Code (IFC) and National Fire Protection
Association (NFPA) .
This project will require seperate permit and fire
sprinkler plans for review.
Call for cover inspection for all sprinkler installations.
A full acceptance test will be required for the fire
sprinkler system.
Owner is responsible for ongoing fire sprinkler system
inspection and testing per the current addition of NFPA 25.
April 7, 2015 2:58:36 PM sroberds.
The proposal will result in a new sfr in the RS-11 zone for
total lot cov of 21°s and site cov of 280. No land use
issues anticipated.
Electrical load calculations and electrical permits are
required.
Ditches & 12" culverts will be installed to City Stanards.
See Public Works Engineering for Standards.
1. Establishing Construction Access.
2. Install sediment controls BMPs.
3. Stabilize exposed soils.
4. Protect slopes from erosion.
S. Protect drain inlets.
6. Control pollutants including but not limited to spills,
concrete wash out, exposed aggregate processes, concrete
grinding and saw cut waste water.
7. Maintain temporary and permanent erosion control BMPS
during project.
All disturbed area's on site not covered by new improvements
should meet the attached soil quality and depth BMP T5.13.
Consider applying for the City Green Infrastructure Rebate
Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes
null and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned
for a period of 180 days after the work has commenced, or if required inspections have not been requested within 180 days from the
last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions
of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does
not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construction.
Date Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder)
--]
T:Forms/Building Division/Building Permit
BUILDING PERMIT INSPECTION RECORD
PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS—
Building Inspections 417-4815 Electrical Inspections 417-4735
Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886
IT IS UNLAWFUL TO COVER,INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED.
POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE.
Inspection Type Date Accepted By Comments
FOUNDATION:
Footings
Stemwall
Foundation Drainage/Downspouts
Piers
Post Holes(Pole Bldgs.)
PLUMBING:
Under Floor/Slab
Rough-In
Water Line Meter to Bldg)
Gas Line
Back Flow/Water FINAL Date Accepted b
AIR SEAL:
Walls
Ceiling
FRAMING:
Joists/Girders/Under Floor
Shear Wall/Hold Downs
Walls/Roof/Ceiling
v
Drywall Interior Braced Panel Only)
T-Bar
INSULATION:
Slab
Wall/Floor/Ceiling
MECHANICAL:
Heat Pum /Furnace/FAU/Ducts
Rough-in
Gas Line
Wood Stove/Pellet/Chimney
Commercial Hood/Ducts FINAL Date Accepted b
MANUFACTURED HOMES:
Footing/Slab
Blocking&Hold Downs
Skirting
PLANNING DEPT. Separate Permit#s SEPA:
Parkin /Lighting ESA:
Landscaping SHORELINE:
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE
Inspection Type Date Accepted By
Electrical 417-4735
Construction- R.W. PW I Engineering 417-4831
Fire 417-4653
Planning 417-4750
Building 417-4815
T:Forms/Building Division/Building Permit
CITY OF PORT ANGELES
DEPARTMENT OF COMMUNITY & ECONOMIC DEVELOPMENT- BUILDING DIVISION
321 EAST 5TH STREET, PORT ANGELES, WA 98362
Page 3
Application Number . . . . . 15-00000343 Date 4/29/15
Application pin number . . . 231476
----------- -------------------- ------------ - REPORT SALES TAX
Special Notes and Comments
of up to $750.00 towards the materials to install rain on your state excise tax form
garden to control roof and driveway runoff. Also rebates to the City of Port Angeles
available for downspout disconnections.Contact Jonathan
Boehme at 360 417-4811 (Location Code 0502)
All construction work within the City right of way requires
a separate Right of Way Construction application to be
completed by the contractor and approved by Public Works
Engineering prior to the start of work. A pedestrian or
traffic control plan is to be submitted for approval with
the application as necessary.
Trench safety per applicable laws. Temp erosion control and
surface restoration responsibility of applicant. Contact
City inspector prior to start of work @ 360 417-4831. No
attachment to sanitary sewer of stormwater roof leaders,
foundation drains, yard drains, or any other CSO
contribution is allowed.
Sanitary sewer connection inspection is required by
Public Works prior to back fill of ditch. 24 hour advance
notice is required. Public Works Inspection request line
417-4831
The contractor making the connection to an existing water
meter is responsible to adjust water meter depth so that
there.is a minimum of 4 to 6 inches of clearance between the
bottom of the meter box lid and the top of the meter at
finish grade.
Construct driveway and Sidewalks to City Standards.
Concrete with exposed aggregate or other non-standard
finishes(including colors or dyes)are not allowed in the
City road right of way. Broom finish only. An inspection by
Public Works Engineering is required prior to pouring
concrete. Public Works inspection request line 417-4831
----------------------------------------------------------------------------
Other Fees . . . . . . . . . RES UNDERGRND SERVICE FEE 770.00
MILW DRIVE ASSESSMENT 240.00
SEWER SYSTEM DELV CHARGE 2260.00
STATE SURCHARGE 4.50
PW WATER SYSTEM-USE FEE 2260.00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
Permit Fee Total 1680.65 1680.65 .00 .00
Plan Check Total 870.64 870.64 .00 .00
Other Fee Total 5534.50 5534.50 .00 .00
Grand Total 8085.79 8085.79 .00 .00
Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes
null and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned
for a period of 180 days after the work has commenced, or if required inspections have not been requested within 180 days from the
last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions
of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does
not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construction.
Date Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder)
T:Forms/Building Division/Building Permit
♦ ^O
BUILDING PERMIT INSPECTION RECORD
- PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS—
Building Inspections 417-4815 Electrical Inspections 417-4735
Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886
IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED.
POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE.
Inspection Type Date Accepted By Comments
FOUNDATION:
Footings
Stemwall
Foundation Drainage/Downspouts
Piers
Post Holes(Pole Bldgs.)
PLUMBING:
Under Floor/Slab
Rough-In
Water Line Meter to Bldg)
Gas Line
Back Flow/Water FINAL Date Accepted b
AIR SEAL:
Walls
Ceiling
FRAMING:
Joists/Girders/Under Floor
Shear Wall/Hold Downs
Walls/Roof/Ceiling
1
Drywall Interior Braced Panel Only)
T-Bar
INSULATION:
Slab
Wall/Floor/Ceiling
MECHANICAL:
Heat Pum /Furnace/FAU/Ducts
Rough-In
Gas Line
Wood Stove/Pellet/Chimney
Commercial Hood/Ducts FINAL Date Accepted b
MANUFACTURED HOMES:
Footing/Slab
Blocking&Hold Downs
Skirting
PLANNING DEPT. Separate Permit#s SEPA:
Parkin /Lighting ESA:
Landscaping SHORELINE:
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE
Inspection Type Date Accepted By
Electrical 417-4735
Construction-R.W. PW /Engineering 417-4831
Fire 417-4653
Planning 417-4750
Building 417-4815
T:Forms/Building Division/Building Permit
THS ��1T ;,�N-GELES For City Use
CITY of � � _
Permit#
W ASH I N G r o N, U . S . Date Received:
321 E Slh Street /Date Approved
Port Angeles,WA 9836
P:360-417-4817 F:360-417-4711
Email: Verrnits(@cityofpa.us BUILDING PERMIT PPLICATION
Project Address: 1224-7 0- ziAA
Phone: 3(0o
Primary Contact: --rt of--,�, SrnlCEP— Email:rrDvp (>f, os, c
Name Phone
.FN Pp'1Z7r [Eg-S 3(O Z) -303
Property Mailing Address Email
Owner -7 b I-P,P,9s 'des- JN
City State Zip
r3t!!:c l/ c�ta POc \d P t 225
Name Phone
�D v 7C N iD R,A\J a 'D �(x P ,�T _3P(00
- Z
Contractor Address Email
—7/0 L-a i�r�3 C;G AJ(✓ 'To�D v PEk-L - .$Yv P AS LU I'
Information city�c ham//r� A State wA zip Z
d 8' z
Contractor License# Exp.Date:
Legal Description: Zoning: Tax Parcel # Project Value: (materials and labor)
Residential 1 Commercial ❑ Industrial ❑ Public ❑
Permit Demolition ❑ Fire ❑ Repair ❑ Reroof(tear off/lay over) ❑
Classification For the following,fill out both pages of permit application:
(check New Construction 'd Exterior Remodel ❑ Addition ❑ Tenant Improvement ❑
appropriate) Mechanical ❑ Plumbing ❑ Other ❑
Fire Sprinkler System Proposed Irrigation System Proposed or Proposed Bathrooms Proposed Bedrooms
or Existing? Yes 0 No D Existing? Yes 1A No 13 Z 3
In addition to standard hard copy submittals please send a PDF copy of all Stormwater plans and Engineering to
wwNv.stormwater@citvo(pa.us
Project Description
�� ) to o
Z G� tZ GP2��v
Is project in a Flood Zone: Yes ® Non Flood Zone Type:
If in a Flood Zone, what is the value of the structure before proposed improvement? $
I have read and completed the application and know it to be true and correct. I am authorized to apply for
1 this permit and understand that it is my responsibility to determine what permits are required and to
obtain permits prior to work. I understand that plan review fees are not refundable after review has
occurred. I understand that I will forfeit review fees if I withdraw the application before the permit is
I issued. I understand that if the permit is not picked up/issued within 18o days of submittal,the application
will be considered abandoned and the fees will be forfeited.
6--A1 CC- /L-
Date A 1'3/ 1 C Print Name Signature
Residential Structures
Existing Proposed Construction For Office Use
Area Descriptions($Q FT) Floor area Floor area $Value new area
Basement
First Floor , &�
Second Floor
Covered Deck/Porch/Entry
Deck(over 30"or 2'dfloor) �J
Garage
Carport
Other(describe)
r
Area Totals
Commercial Structures
Area Descriptions(SQ FT) Existing Proposed Construction For Office Use
Floor area Floor area $Value new area
Existing Structure (s)
Proposed Addition
Tenant Improvement?
Other work(describe) _----_---_--- _--- -_--_-- -- - -- - - _ - _
Site Area Totals
Lot/Site Covera a Calculations y
Lot Size (sq ft) Lot Coverage(sq ft)foot print of %Lot Coverage(Total lot cov_lot size) Max Bldg Height
11 3 3 � all structures 'Z3 s ft 2s) , % /5
Site Coverage(Sq Ft of all impervious) %of Site Coverage(total site cov_lot size)
31 AP "7-?, b .-
Mechanical Fixtures
Indicate how many of each type of fixture to be installed or relocated as part of this project.
Air Handler Size: # Haz/Non-Haz Piping Outlets:
Appliance Exhaust Fan # Heater(Suspended, Floor,Recessed wall) #
Boiler/Compressor Size: # Heating/Cooling appliance #
repair/alteration
Evaporative Cooler(attached,not # Pellet Stove/Wood-burning/Gas #
portable) Fireplace/Gas Stove/Gas Cook Stove/Misc.
Fuel Gas Piping #of Outlets: Ventilation Fan,single duct #
3
Furnace/Heat Pump/ Size: # Ventilation System #
Forced Air Unit 'L V- g;J j
Plumbing Fixtures
Indicate how many of each type of fixture to be installed or relocated
Plumbing Traps # Water Heater #
Plumbing Vent piping # Medical gas piping #of Outlets:
Water Line # Fuel gas piping #of Outlets:
Sewer Line # Industrial waste pretreatment
interceptor Grease Trap) Size
Other(describe):
T:\BUILDING\APPLICATION FORMS\Current BP Application\Building Permit 4-17-13.docx
TIGHTLINE TIED TO - - - - - -
D WN P • °•
/ 0 S OUTS G ' I
/ DRAIN-DA HT
/ TO DIT
CULVE 0,
CONDENSER ON
CONC PAD0 Lu
I i
\ - / I WATER LINE
bo
SEWE i
81-011
/ELEC 46AL31*
SETBACK L — — — — — —
/ / ^ \ EW - - - - -
// \ \ I
\
- - - - - - - - - - - - - SE-�g�G
m
E N t— - - - - - - -
- - - - - - - - - - - -- - v
SITE PLAN =
1"=30' _
JUAN de FUCA BLUFFS
1217 DUTCH DRIVE SUE PIAN
PORT ANGELES, WA 98363 Al
'tes,�giptive Energy Code C6rripiia4ce;for:AB Cl.irnat6.Zon'es iti Washington'::
! ProjectArlorination;� - �Coirtact•tafvirrratan:'
�.+Ct'��+�. fi.�i �E51�L'",.�3..��3�..7 r _.S a �' �wm. .m�`�" �i'�° y!'. ,.k s mna..,r�...,.�.� .v.I��'s��;'4s43 ,�-•.--�-•.--�» '_
:This project will use'the:requirements of the Piescriptive Path below,acid incorporate the•. : : : : : : : : : : : : : : :
: the:minimurri values:listed:In addition,:based oh•the:siie vf1he•structiure,the appropriate:;: : : :
:nrimher'df•additional credits are checked:as chosen by the permit:aPplicant' : : ::: : ::::: :-: : :::
Authoiized:Representative: :;Date
•R-Veluea:' :U-Facfara
Fenestration:U'Fadorb: n/a 0.30
Skylight U-Factor: n/a 0.50
Glazed;FenestratlDn:SHGC° n/a n/a
Ceilin 49' 0.026
Wood:Fram e'Wall9"�' 21 int 0.056
Mas V66 R-Valbe'.- 21/21" 0.056
Floor 309 0.029
Below Grade Wall``: 10/15/21 int+TB 0.042
Slab°R-Value&Ce'th;' 10,2 ft n/a
:`Table 8402:1•.1 and:Table R402.1.3:Fdotnotes:indutled:dn Page:2.:
Each dwelling unit in one and two-family dwellings and townhouses,as defined in Section 1012 of the International Residential Code shall comply with
: sufficient options from Table R406.2 so as to achieve the following minimum number of credits:
❑.Small Dwelling Unit: 0.5 points
Dwelling units less than 1500 square feet in conditioned floor area with less than 300 square feet of fenestration area Additions to existing building that
are less than 750 square feet of heated floor area.
r7�1.Medium Dwelling Unit: 1.5 points
All dwelling units that are not included in#1 or#3,including additions over 750 square feet.
Large Dwelling Unit: 2.5 points
Dwelling units exceeding 5000 square feet of conditioned floor area.
-Table 8406.2^Summary:
Optio De•sciiptiori :Credit(s):
1a:- ;Efficient-Building Envelcpe�1a: 0�5• :Q•S',
1b:` :Efficient'Building Envelope:lb:
1E-' •Effrcient:Buildin`9 Ehvelo e:1d 20:
P.
. - '�
2a. Air:CeEfferent Vent lation 2a• D;5 :❑
2b• Air:L•eakbge•Cobtrol•and Effrcierit•Ventilation 2b: :1 0
2c:• :Air-Leakage:Control:and Efficient_Ventilation'2c- J-5
3a. High EfficiencyHVAC3a: 0'5'
3b•` High Efficiency HVAC 36 •Q,.
3c: :High Efficiency.HVAC-3c: 20
:38•' High EfficiendyHVAC 3d•'
4: ;High Efficiency_HVAC Distribution System• 1�0
5a:' Effcient'Water.Heating
5b-' j Efficient:Water-Heatirig: :1:5
Renewable Electric Energy. D S `-1200 :Q•Q':
:Totel:Credits
*Please:refer:to Table R406 2-for'.complete:option de'scr'iptions:
http://www.energy.wsu.edu/Documents/201 2%20Res%20Energy_pdf
Table R402.1.1 Footnotes
For A 1 foot .= 304.8 mm, ci .=continuous insulation, int.= intermediate framing.
a R-values are minimums. U-factors and SHGC are maximums. When insulation is installed in a cavity which is less than the label
or design thickness of the insulation, the compressed R-value of the insulation from Appendix Table Al 01.4 shall not be less
than the R-value specified in the table.
b The fenestration U-factor column excludes skylights.The SHGC column applies to all glazed fenestration. Exception: Skylights
may be excluded from glazed fenestration SHGC requirements in Climate Zones 1 through 3 where the SHGC for such skylights
does not exceed 0.30.
"'10/15/21-.+TB" means R-10 continuous insulation on the exterior of the wall, or R-15 on the continuous insulation on the
interior of the wall, or R-21 cavity insulation plus a thermal break between the slab and the basement wall at the interior of the
basement wall. "10/15/21.+TB" shall be permitted to be met with R-13 cavity insulation on the interior of the basement wall
plus R-5 continuous insulation on the interior or exterior of the wall. "10/13" means R-10 continuous insulation on the interior
or exterior of the home or R-13 cavity insulation at the interior of the basement wall. "TB" means thermal break between floor
slab and basement wall.
d R-10 continuous insulation is required under heated slab on grade floors. See R402.2.9.1.
e There are no SHGC requirements in the Marine Zone.
f Basement wall insulation is not required in warm-humid locations as defined by Figure R301.1 and Table R301.1.
9 Reserved.
h First value is cavity insulation, second is continuous insulation or insulated siding, so "13.+5" means R-13 cavity insulation.
plus R-5 continuous insulation or insulated siding. If structural sheathing covers 40 percent or less of the exterior, continuous
insulation R-value shall be permitted to be reduced by no more than R-3 in the locations where structural sheathing is used to
maintain a consistent total sheathing thickness.
'The second R-value applies when more than half the insulation is on the interior of the mass wall.
i For single rafter-or joist-vaulted ceilings, the insulation may be reduced to R-38.
k Int. (intermediate framing) denotes standard framing 16 inches on center with headers insulated with a minimum of R-10
insulation.
Log and solid timber walls with a minimum average thickness of 3.5 inches are exempt from this insulation requirement.
Table R402.1.3 Footnote
a Nonfenestration U-factors shall be obtained from measurement, calculation or an approved source or as specified in Section
R402.1.3.
BRACE ® WALL LINE CALCULATI ® NS
BWL A BASED ON WIND(100 MPH): BWL I BASED ON WIND(100 MPH):
BWL SPACING=18' =2.8' BWL SPACING=20' =4.0'
FACTORS: FACTORS:
EXPOSURE D: 1.50 EXPOSURE D: 1.50
RIDGE HEIGHT=6: x.73 RIDGE HEIGHT=6': -0.73
WALL HEIGHT=8': 0.90 WALL HEIGHT=9: 0.90
#BWL=4: 1.45 #BWL=4: 1.45
TOTAL FACTOR: 1.43 TOTAL FACTOR: 1.43
TOTAL BWP=2.8-1.43 =4.00' TOTAL BWP=4.0"1.43 =5.77
BASED ON SDC(D2) BASED ON SDC(D2)
BWL LENGTH=63' =13.33' BWL LENGTH=18' =3.86'
FACTORS: FACTORS:
STORY HEIGHT=8': 1.00 STORY HEIGHT=8': 1.00
BWL SPACING=18': 1.00 BWL SPACING=20': 1.00
WALL DEAD LOAD=<15 PSF: 1.00 WALL DEAD LOAD=<15 PSF: 1.00
ROOF/CEILING DEAD LOAD=<15 PSF(ROOF ONLY): 1_00 ROOF/CEILING DEAD LOAD=<15 PSF(ROOF ONLY): 1.00
TOTAL FACTOR: 1.00 TOTAL FACTOR: 1.00
TOTAL BWP=13.33'•1.00 =13.33' TOTAL BWP=3.86'`1.00 =3.86'
BWL B BASED ON WIND(100 MPH): BWL 2 BASED ON WIND(100 MPH):
BWL SPACING=16' =2.8' BWL SPACING=20' =4.0'
FACTORS: FACTORS:
EXPOSURE D: 1.50 EXPOSURE D: 1.50
RIDGE HEIGHT=6': 0.73 RIDGE HEIGHT=6': 0.73
WALL HEIGHT=IT: 0.90 WALL HEIGHT=8': 0.90
#BWL=4: 1.45 #BWL=4: 1.45
TOTAL FACTOR: 1.43 TOTAL FACTOR: 1.43
TOTAL BWP=2.8"1.43 =4.00' TOTAL BWP=4.0"1.43 =5.72'
BASED ON SDC(D2) BASED ON SDC(D2)
BWL LENGTH=63' =13.33' BWL LENGTH=53' =11.23'
FACTORS: FACTORS:
STORY HEIGHT=8': 1.00 STORY HEIGHT=B': 1.00
BWL SPACING=18': 1.00 BWL SPACING=20': 1.00
WALL DEAD LOAD=<15 PSF: 1.00 WALL DEAD LOAD=<15 PSF: 1.00
ROOF/CEILING DEAD LOAD=<15 PSF(ROOF ONLY): 1.00 ROOF/CEILING DEAD LOAD=<15 PSF(ROOF ONLY): 1.00
TOTAL FACTOR: 1.00 TOTAL FACTOR: 1.00
TOTAL BWP=13.33"1.00 =13.33' TOTAL BWP=3.86"1.00 =1113'
BWL C BASED ON WIND(100 MPH): BWL 3 BASED ON WIND(100 MPH):
BWL SPACING=21' =4.2' BWL SPACING=25' =5.0'
FACTORS: FACTORS:
EXPOSURE D: 1.50 EXPOSURE D: 1.50
RIDGE HEIGHT=6': 0.73 RIDGE HEIGHT=6': 0.73
WALL HEIGHT=6': 0.90 WALL HEIGHT=8': 0.90
#BWL=4: 1.45 #BWL=4: 1.45
TOTAL FACTOR: 1.43 TOTAL FACTOR: 1.43
TOTAL BWP=4.2"1.43- =6.01' TOTAL BWP=5.0"1.43 =5.00'
BASED ON SDC(132) BASED ON SDC(D2)
BWL LENGTH=46 =9.76' BWL LENGTH=53' =11.23'
FACTORS: FACTORS:
STORY HEIGHT=8': 1.00 STORY HEIGHT=8': 1.00
BWL SPACING=21': 1.00 BWL SPACING=20': 1.00
WALL DEAD LOAD=<15 PSF: 1.00 WALL DEAD LOAD=<15 PSF: 1.00
ROOF/CEILING DEAD LOAD=<15 PSF(ROOF ONLY): 1.00 ROOF/CEILING DEAD LOAD=<15 PSF(ROOF ONLY): 1.00
TOTAL FACTOR: 1.00 TOTAL FACTOR: 1.00
TOTAL BWP=9.76"1.00 =9.76' TOTAL BWP=3.86"1.00 =11.23'
BWL D BASED ON WIND(100 MPH): BWL 4 BASED ON WIND(100 MPH):
BWL SPACING=21' =4.2' BWL SPACING=25' =5.0'
FACTORS: FACTORS:
EXPOSURE D: 1.50 EXPOSURE D: 1:50
RIDGE HEIGHT=6': 0.73 RIDGE HEIGHT=6': 0.73
WALL HEIGHT=8': 0.90 WALL HEIGHT=8': 0.90
#BWL=4: 1.45 #BWL=4: 1.45
TOTAL FACTOR: 1.43 TOTAL FACTOR: 1.43
TOTAL BWP=4.2-11.43 =6.01' TOTAL BWP=5.0-1.43 =5.00'
BASED ON SDC(D2) BASED ON SDC(D2)
BWL LENGTH=24' =5.14' BWL LENGTH=32' =6.82'
FACTORS: FACTORS:
STORY HEIGHT=8': 1.00 STORY HEIGHT=8': 1.00
BWL SPACING=21': 1.00 BWL SPACING=20': 1.00
WALL DEAD LOAD=<15 PSF: 1.00 WALL DEAD LOAD=<15 PSF: 1.00
ROOF/CEILING DEAD LOAD=<15 PSF(ROOF ONLY): 1.00 ROOF/CEILING DEAD LOAD=<15 PSF(ROOF ONLY): 1.00
TOTAL FACTOR: 1.00 TOTAL FACTOR: 1.00
TOTAL BWP=5.14"1.00 =5.14' TOTAL 13WP=6.82"1.00 =6.82'