PREPARED 12/02/16, 8:50:18 INSPECTION TICKET PAGE 2
CITY OF PORT ANGELES INSPECTOR: JAMES LIERLY DATE 12/02/16
------------------------------------------------------------------------------------------------
ADDRESS . : 1315 DUTCH DR SUBDIV:
CONTRACTOR DUTCH DRIVE DEVELOPMENT LLC PHONE (360) 565-6269
OWNER : PA PARTNERS LLC PHONE
PARCEL 06-30-01-8-0-0200-0000-
APPL NUMBER: 15-00001174 RES NEW SFR
----------------------- ---
PERMIT: BPR 00 BUILDING PERMIT - RESIDENTTAT•
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------ ---------
BL1 01 5/23/16 JLL BLDG FOUNDATION FOOTING
5/23/16 AP May 23, 2016 9:16:49 AM jlierly.
Todd 565-6269
May 23, 2016 4:07:23 PM jlierly.
BL2 01 5/27/16 JLL BLDG FOUNDATION STEM WALL
5/27/16 AP May 27, 2016 8:39:52 AM jlierly.
ERIC 808-5647
May 27, 2016 4:14:54 PM jlierly.
BFF 01 7/01/16 PB BLDG FLOOR FRAMING
7/05/16 AP July 1, 2016 12:06:01 PM pbarthol.
todd 565-6269
July 5, 2016 9:29:26 AM pbarthol.
BEXS 01 8/18/16 JLL BLDG EXTERIOR SHEETING _
8/18/16 AP August 18, 2016 8:10:24 AM jlierly.
Todd 565-6269
August 18, 2016 4:50:01 PM jlierly.
BEXS 02 8/30/16 JLL BLDG EXTERIOR SHEETING
_ 8/31/16 AP August 30, 2016 8:37:05 AM jlierly.
todd 565-6269
August 31, 2016 8:27:20 AM jlierly.
BAIR O1 10/17/16 JLL BLDG AIR SEAL
10/17/16 AP October 17, 2016 1:58:18 PM jlierly.
Todd 565-6249
October 17, 2016 3:41:02 PM jlierly.
BL3 01 10/17/16 JLL BLDG FRAMING
10/17/16 AP October 17, 2016 1:58:50 PM jlierly.
October 17, 2016 3:41:02 PM jlierly.
BLWS 01 10/20/16 JLL BLDG INSULATION WALL/FLOOR
10/20/16 AP October 20, 2016 9:20:06 AM jlierly.
Todd 565-6266
October 20, 2016.4:23:26 PM jlierly.
PW99 01 11/30/16 RV PUBLIC WORKS FINAL
12/01/16 AP December 1, 2016 10:03:32 AM rvess.
December 1, 2016 10:04:20 AM rvess.
BL99 01 12/02/16 BLDG FINAL
December 2, 2016 8:54:15 AM jlierly.
Todd 775-241-8809
PERMIT: ME 00 MECHANICAL PERMIT
REQUESTED - INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
ME1 01 10/17/16 JLL MECHANICAL ROUGH-IN .
10/17/16 AP October 17, 2016 2:01:05 PM jlierly.
October 17, 2016 3:41:02 PM jlierly.
ME99 01 12/02/16 JLL MECHANICAL FINAL
----------------------------------- CONTINUED ONTO NEXT PAGE ---------------------------------
PREPARED 12/02/16, 8:50:18 INSPECTION TICKET PAGE 3
CITY OF PORT ANGELES INSPECTOR: JAMES LIERLY DATE 12/02/16
--------------- -
ADDRESS : 1315 DUTCH DR SUBDIV:
CONTRACTOR DUTCH DRIVE DEVELOPMENT LLC PHONE (360) 565-6269
OWNER PA PARTNERS LLC PHONE
PARCEL 06-30-01-8-0-0200-0000-
APPL NUMBER: 15-00001174 RES NEW SFR
-------------------------—--------------—----------------------------—----------------------
REQUESTED fNS DESCRIPTION
TYP/SQ COMPLETED RESULTS/COMMENTS
------- - - - --------- -- --------
--------------------- ---- —
December 2, 2016 8:54:47 AM jlierly.—
PERMIT: PL 00 PLUMBING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
PL2 .01 10/17/16 JLL PLUMBING ROUGH-IN
10/17/16 AP October 17, 2016 2:01:24 PM jlierly.
October 17, 2016 3:41:02 PM jlierly. -
PL99 01 12/02/16PLUMBING FINAL
December 2, 2016 8:54:58 AM jlierly.
--------------------
-- -------- -- ------------ COMMENTS AND NOTES --------------------------------------
►. CITY OF PORT ANGELES
DEPARTMENT OF COMMUNITY & ECONOMIC DEVELOPMENT- BUILDIN VISION.
32,1 EAST 5TH STREET, PORT ANGELES, WA 98362
Application Number . . . . . 15-00001174 Date 4/27/16
Application pin number . . . 408200
Property Address . . . . . . 1315 DUTCH DR REPORT SALES TAX
ASSESSOR PARCEL NUMBER: 06-30-01-8-0-0200-0000-
Application type description RES NEW SFR on your state excise tax form
Property
Name . . . . . . to the City of Port Angeles
Pro ert Use
Property Zoning . . . . . . . RS9 RESDNTL SINGLE FAMILY (Location Code 0502
Application valuation . . . . 152792
-----------------------------------------------------------
Application desc
1 STY 3BED 2 BATH 1580SF SFR W/566SF GARAGE
----------------------------------------------------------------------------
Owner Contractor
------------------------ ------------------------
PA PARTNERS LLC DUTCH DRIVE bEVELOPMENT LLC
710 LARRABEE AVE 710 LARRABEE AVE
BELLINGHAM WA 98225 BELLINGHAM
BELLINGHAM WA 98225
(3 60) 565-6269
----------------------------------------------------------------------------
Permit . . . . . . BUILDING PERMIT -RESIDENTIAL
Additional desc 2272SF 1 STRY SFR
Permit Fee . . . . 1317.05 Plan Check Fee 856.08
Issue Date . . . . 4/27/16 Valuation . . . . 152792
Expiration Date 10/24/16
(. Qty Unit Charge Per Extension
BASE FEE 1020.25
53.00 5.6000 THOU BL-100,001-500K (5.60 PER K) 296.80
y ----------------------------------------------------------------------------
�' Permit . . . . . . MECHANICAL PERMIT
r Additional desc SFR MECHANICAL
Permit Fee . . . . 97.20 Plan Check Fee .00
4 Issue Date . . . . 4/27/16 Valuation . . . . 0
S Expiration Date 10/24/16
* Qty Unit Charge Per Extension
BASE FEE 50.00
1.00 14.8000 EA ME-FURN/HP/FAU < OR = 5 TON 14.80
'^ 3.00 7.2500 EA ME-VENT FAN (S,INGLE DUCT) 21.75
v 1 1.00 10.6500 EA ME-HOOD/DUCT-MECH. EXHAUST 10.65
----------------------------------------------------------------------------
`vJ Permit . . . . PLUMBING PERMIT
�- Additional desc SFR PLUMBING
Permit Fee . . . . 149.00 Plan Check Fee .00
Issue Date . . . 4/27/16 Valuation . . . . 0
Expiration Date 10/24/16
Qty Unit Charge Per Extension
BASE FEE 50.00
7.00 7.0000 EA PL-PLUMBING TRAP 49.00
1.00 7.0000 EA PL-WATER LINE 7.00
i 3.00 7.0000 EA PL-DRAIN VENT PIPING 21.00
ff`
t/� Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes
null and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned
for a period of 180 days after the work has commenced, or if required inspections have not been requested within 180 days from the
last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions
of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does
not presume to give authority to violate or cancel the provisions of any state or local law regulating construct' rmance of
const5pictiop.
Date Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder)
T:Forms/Building Division/Building Permit
t
.BUILDING PERMIT INSPECTION RECORD
+�. R ASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS—
Buik g Inspections 417-4815 Electrical Inspections 417-4735
Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886
IT IS UNLAWFUL TO COVER,INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED.
POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE.
Inspection Type Date Accepted By Comments
FOUNDATION:
Footings
Stemwall
Foundation Drainage/Downspouts
Piers
Post Holes(Pole Bldgs.)
PLUMBING:
Under Floor/Slab
Rough-In
Water Line Meter to Bldg)
Gas Line
Back Flow/Water
AIR SEAL:
Walls
Ceiling
FRAMING:
Joists/Girders/Under Floor
Shear Wall/Hold Downs
Walls/Roof/Ceiling
Drywall Interior Braced Panel Only)
T-Bar
INSULATION:
Slab
Wall/Floor/Ceiling
MECHANICAL:
Heat Pump/Furnace/FAU/Ducts
Rough-In
Gas Line
Wood Stove/Pellet/Chimney
Commercial Hood/Ducts
MANUFACTURED HOMES:
Footing/Slab
Blocking&Hold Downs
Skirting
PLANNING DEPT. Separate Permit#s SEPA:
Parkin /Lighting ESA:
a
Lndscaping SHORELINE:
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE
Inspection Type _ Date Accepted By
Electrical 417-4735
Construction -R.W. PW /Engineering 417-4831
Fire 417-4653
Planning 417-4750
Building 417-4815
n�E
CITY OF PORT ANGELES
go; DEPARTMENT OF COMMUNITY & ECONOMIC DEVELOPMENT- BUILDING DIVISION
321 EAST 5TH STREET, PORT ANGELES, WA 98362
Page 2 ,
Application Number . . . . . 15-00001174 Date 4/27/16
Application pin number . . . 408200 REPORT SALES TAX
Qty Unit Charge Per Extension on your state excise tax form
1.00 15.0000 EA PL-SEWER LINE
1
1.00 7.0000 EA PL-WATER HEATER 7.00 to the City of Port Angeles
---------------------------------------------------------------
Special Notes and Comments (Location Code 0502)
September 24, 2015 9:11:59 AM rbecker.
If you are installing a closed fire system, you will need to
install a double check valve assembly. If you are installing
an open fire system, then you do noy need to install a
backflow assembly.
If you have any questions call Ron Becker at 360-417-4886,
Fax:366-452-4972, or E-mail:rbecker@cityofpa.us
Address numbers shall be plainly visible from the street.
Address numbers shall be a minimum of six inches high and be
of contrasting color from-.the background.
Call for cover inspection for all sprinkler installations.
A full acceptance test will be required for the fire
sprinkler system.
This project will require seperate permit and fire
sprinkler plans for review.
October 7, 2015 9:56:53 AM pbarthol.
project will result in a single story 2272sf SFR with 20.6%
lot coverage and 24.6% site coverage. Setbacks ok per the
Site plan provided.
Electrical load calculations and electrical permits are
required.
Ditches & 12" culverts will be installed to City Standards.
See Public Works Engineering for Standards.
r 1. Establishing Construction Access.
2. Install sediment controls BMPs.
3. Stabilize exposed soils.
4. Protect slopes from erosion.
5. Protect drain inlets.
G. Control pollutants including but not limited to spills,
concrete wash out, exposed aggregate processes, concrete
grinding and saw cut waste water.
7. Maintain.temporary and permanent erosion control BMPS
during project.
All disturbed area's on site not covered by new improvements
should meet the attached soil quality and depth standard. "
Consider applying for the City Green Infrastructure Rebate
of up to $750.00 towards the materials to install rain
garden to control roof and driveway runoff. Also rebates
available for downspout disconnections.Contact Jonathan
Boehme at 360 417-4811
All construction work within the City right of way requires
a separate Right of Way Construction application to be
completed by the contractor and approved by Public Works
Engineering prior to the start of work. A pedestrian or
Separate Permits are required forelectrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes
null and void if work or construction authorized isnot commenced within 180 days,if construction or work is suspended or abandoned
for a period of 180 days after the work has commenced, or if required inspections have not been requested within 180 days from the
last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions
of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does
not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construction.
Date Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder)
T:Forms/Building Division/Building Permit
BUILDING PERMIT INSPECTION RECORD
PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS—
Building Inspections 417-4815 Electrical Inspections 417-4735
Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886
IT IS UNLAWFUL TO COVER,INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED.
POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE.
Inspection Type Date Accepted By Comments
FOUNDATION:
Footings
Stemwall
Foundation Drainage/Downspouts
Piers
Post Holes(Pole Bldgs.)
PLUMBING:
Under Floor/Slab
Rough-in
Water Line Meter to Bldg)
Gas Line
Back Flow/Water
AIR SEAL:
Walls
Ceiling
FRAMING:
Joists/Girders/Under Floor
Shear Wall/Hold Downs
Walls/Roof/Ceiling
Drywall Interior Braced Panel Only)
T-Bar
INSULATION:
Slab
Wall/Floor/Ceiling
MECHANICAL:
Heat Pum /Furnace/FAU/Ducts
Rough-in
Gas Line
Wood Stove/Pellet/Chimney
Commercial Hood/Ducts
MANUFACTURED HOMES:
Footing/Slab
Blocking&Hold Downs
Skirting
PLANNING DEPT. Separate Permit#s SEPA:
Parkin /Lighting ESA:
Landscaping I ISHORELINE:
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE
Inspection Type _ Date Accepted By
Electrical 417-4735
Construction -R.W. PW /Engineering 417-4831
Fire 417-4653
Planning 417-4750
Building 417-4815
%' CITY OF PORT ANGELES
� DEPARTMENT OF COMMUNITY & ECONOMIC DEVELOPMENT- BUILDING DIVISION
t. r�
321 EAST 5TH STREET, PORT ANGELES, WA 98362
Page 3
Application Number . . . . . 15-00001174 Date 4/27/16
Application pin number . . . 408200
----------------------- ---------------------------------- REPORT SALES TAX
Special Notes and Comments on your state excise tax form
traffic control plan is to be submitted for approval with to the Cit of Port Angeles
the application as necessary. y 9
Sanitary sewer connection inspection is required by (LOCaIf/O/ii COC@ 0502)
Public Works prior to back fill of ditch. 24 hour advance
notice is required. Public Works Inspection request line
417-4831
Trench safety per applicable laws. Temp erosion control and
surface restoration responsibility of applicant. Contact
City inspector prior to start of work @ 360 417-4831. No
attachment to sanitary sewer of stormwater roof leaders,
foundation drains, yard drains, or any other CSO
contribution is allowed.
Construct driveway to City Standards. Concrete with exposed
aggregate or other non-standard finishes(including colors or
dyes)are not allowed in the City road right of way. Broom
finish only. An inspection'by Public Works Engineering is
required prior to pouring concrete. Public Works inspection
- request line 417-4831
The contractor making the connection to an existing water
meter is responsible to adjust water meter depth so that
there is a minimum of 4 to 6 inches of clearance between the
bottom of the meter box lid and the top of the meter at
finish grade.
----------------------------------------------------------------------------
Other Fees . . . . . . . . . RES UNDERGRND SERVICE FEE 770.00
MILW DRIVE ASSESSMENT 240.00
SEWER SYSTEM DELV CHARGE 2260.00
STATE SURCHARGE 4.50
PW WATER SYSTEM USE FEE 2260.00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 1563.25 1563.25 .00 .00
Plan Check Total 856.08 856.08 .00 .00
Other Fee Total 5534.50 5534.50 .00 .00
Grand Total 7953.83 7953.83. .00 .00
Separate Permits are required forelectrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes
null and void if work or construction authorized isnot commenced within.180 days,if construction or work is suspended or abandoned
for a period of 180 days after the work has commenced, or if required inspections have not been requested within 180 days from the
last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions
of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does
not presume to give authority to violate or cancel the provisions 9 9
9 Y of an state or local
P y o law regulating construction or the performance of
construction.
Date Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder)
T:Forms/Building Division/Building Permit
BUILDING PERMIT INSPECTION RECORD
PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS—
Building Inspections 417-4815 Electrical Inspections 417-4735
Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886
IT IS UNLAWFUL TO COVER,INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED.
POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE.
Inspection Type Date Accepted By Comments
FOUNDATION:
Footings
Stemwall
Foundation Drainage/Downspouts
Piers
Post Holes(Pole Bldgs.)
PLUMBING:
Under Floor/Slab
Rough-In
Water Line Meter to Bldg)
Gas Line
Back Flow/Water
AIR SEAL:
Walls
Ceiling
FRAMING:
Joists/Girders/Under Floor
Shear Wall/Hold Downs
Walls/Roof/Ceiling
Drywall Interior Braced Panel Only)
T-Bar
INSULATION:
Slab
Wall/Floor/Ceiling
MECHANICAL:
Heat Pump/Furnace/FAU/Ducts
Rough-in
Gas Line
Wood Stove/Pellet/Chimney
Commercial Hood/Ducts
MANUFACTURED HOMES:
Footing/Slab
Blocking&Hold Downs
Skirting
PLANNING DEPT. Separate Permit#s SEPA:
Parkin /Lighting ESA:
Landscaping SHORELINE:
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE
Inspection Type _ Date Accepted By
Electrical 417-4735
Construction - R.W. PW I Engineering 417-4831
Fire 417-4653
Planning 417-4750
Building 417-4815
CIT �RT NGELES ; For City Use
CITY OF a
_ _ - - Permit#
W A s H INGTO N, U. S. ^tl Date Received:
321 E 51h Street f ate Approved
Port Angeles,WA 9836
P:360-417-4817 F:360-417-4711
Email:permits0citvofpa.us BUILDING PERMI APPLICATION
Project Address: )3!!57' --r C -> J s
Phone: 3(6?O .s
Primary Contact:—Tp (, Email:
Name Phone
0A 3(ao
Property Mailing Address Email
Owner ?I o t-�4 iZRA i C- &JG
City State Zip
92.ZS�
Name Phone
tpv-rc�A JIF- DC Lts�►Mme/ - 300 o
Contractor Address Email
Information -710 La`���'
City EI--. )At' State �Irj� Zip 22
Contractor License# Exp.Date:
Legal Description: Zoning: Tax Parcel # Project Value: (materials and labor)
�T ZD -39 r VCa s3LQ._rs U3W 18G®-4-o 0 1 s 16-2— 792--
Residential Commercial ❑ Industrial ❑ Public ❑
Permit Demolition ❑ Fire ❑ Repair ❑ Reroof(tear off/lay over) ❑
Classification For the following, fill out both pages of permit application:
(check New Construction/�Q Exterior Remodel ❑ Addition ❑ Tenant Improvement ❑
appropriate) Mechanical ❑ Plumbing ❑ Other ❑
Fire Sprinkler System Proposed Irrigation System Proposed or Proposed Bathrooms Proposed Bedrooms
or Existing? Yes ANo 0 Existing? Yes O No 2 3
In addition to standard hard copy submittals please send a PDF copy of all Stormwater plans and Engineering to
www.stormwaterocityofpa.us
Project Description
I�C: i LJ—� '-tc9Z- — w C-06,h P"A
Is project in a Flood Zone: Yes 0 Noig Flood Zone Type:
If in a Flood Zone, what is the value of the structure before proposed improvement? $
I have read and completed the application and know it to be true and correct. I am authorized to apply for
this permit and understand that it is my responsibility to determine what permits are required and to
obtain permits prior to work. I understand that plan review fees are not refundable after review has
occurred. I understand that I will forfeit review fees if I withdraw the application before the permit is
issued. I understand that if the permit is not picked up/issued within iSo days of submittal,the application
will be considered abandoned and the fees will be forfeited.
�� �, — ,� s,�e ,•� CC lZ
Date Print Name Signature
Residential Structures
Existing Proposed Construction For Office Use
Area DesdriprigrLgs(SQ FT) Floor area Floor area $Value new area
Basement
First Floor p 2j
ISY�U
Second Floor
Covered Deck/Porch/Entry
Deck(over 30"or 2 Id floor)
Garage
Carport
Other(describe)
Area Totals ,Z -� /SZ ?Z1
Commercial Structures
Area Descriptions(SQ FT) Existing Proposed Construction For Office Use
Floor area Floor area $Value new area
Existing Structure (s)
Proposed Addition
Tenant Improvement?
Other work(describe)
Site Area Totals
Lot/Site Coverage Calculations
Lot Size(sq ft) Lot Coverage(sq ft)foot print of %Lot Coverage(Total lot cov=lot size) Max Bidg/Height
11 t7 L;-2— all structures 2°L'7'Z sq ft 2a r (U,% /5
Site Coverage(Sq Ft of all impervious) %of Sitee Coverage(total site cov_lot size)
Mechanical Fixtures
Indicate how many of each type of fixture to be installed or relocated as part of this project.
Air HandlerSize: # Haz/Non-Haz Piping Outlets:
Appliance Exhaust Fan # Heater(Suspended,Floor,Recessed wall) #
Boiler/Compressor Size: # Heating/Cooling appliance #
repair/alteration
Evaporative Cooler(attached,not # Pellet Stove/Wood-burning/Gas #
portable) Fireplace/Gas Stove/Gas Cook Stove/Misc.
Fuel Gas Piping #of Outlets: Ventilation Fan,single duct #
Furnace/Heat Pump/ Size: # Ventilation System #
Forced Air Unit IIZ-V- `T U
Plumbing Fixtures
Indicate how many of each type of fixture to be installed or relocated
Plumbing Traps # I Water Heater #
Plumbing Vent piping # Medical gas piping #of Outlets:
Water Line # Fuel gas piping #of Outlets:
Sewer Line # j Industrial waste pretreatment
interceptor Grease Trap) Size
Other describe
T:\BUILDING\APPLICATION FORMS\Current BP Application\Building Permit 4-17-13.docx
DUTCH DRIVE
WATER LINE CULVERT
EXIST DRAINAGE
•
DITCH-
84j:
ITCH-
• z
Q� w. w
�5..
18_011 \�� N 3:o n N ELECTRICAL
SETBACK — < / — i SEWER
COVERED
LgRY NEW SFD
CONDENSER ON
CONC PAD
LJLu ♦ \\ I
COVERED PATIOS I I
o \
-011
,-I I ° S I�TBACK
\ TIGHTLINE TIED TO
\\ I I DOWNSPOUTS&FTG
DRAIN-DAYLIGHT
\ % I \TO DITCH
I I I I I i
SITE PLAN NORTH
1" = 30'
JUAN de FUr%..,/-%A BLUFFS
1315 DUTCH DRIVE SITE PLAN
PORT ANGELES, WA 98363 Al
I
60'-8" I
I I
12
WC I
1 SINK DW II SHOWE -
W II
MSTR BATH
11'-0"x 9'-4"
i I Q P I Sv CPT
GREAT ROOM ,r---- L J I 75 dm I I
15'-0"x 20'-10" KITCHEN to I vaNrrY
-------------- --
CATHEDRAL CEILING 3 ;; 9'-11"x 15'-6" 5 I I _ . LINEN MASTER BEDROOM
--------------------
------ �+;-- -------- '-
® 15 8"x12 6"
LLJCATHEDRAL CEILING
WI C ® I
T12"X 5'-0"
ii PANTRY DESK L--- EM ENCY
U ESCA
3I
I o
-------- -------- --------------�--- rii 5 113 I I �I I ® CLOSET w/R&S I F-
L13 Jit 3 L❑-J - I I 3 3 rn
ii vii q � I LU of
HB I :o ry I i L " • �, CLOS I I w ;-4
I I-- - I- x r -1 a = r, >
I F, w 'P I T� . I F<-lx I
DN 0 I x I °° - i� BEDROOM 3 I BEDROOM 2
., LU 75 I 12'-3"x 10'-10'
I > �' 3 W 1 3 12'-3"X 11'-2"
O N DRY 75 cfm
Ln
6 Fu
x T-7" I-1 I
�U - -
T - - - - - -
STEP 8 EMERGENCY I EMERGENCY
Q ESCAPE ESCAPE
I I
- HW HTR
I
I
I
I
� I I
Prescriptive Energy Code Compliance for All Climate Zones in Washington
Project Information Contact Infouna6on
Lot 20 Juan de Fuca Bluffs Todd Spencer
1311 Dutch Drive Upperleft Studios
Port Angeles WA 98363 todd@upperleftstudios.com 360-565-6269
This project will use the requirements of the Prescriptive Path below and incorporate the
the minimum values listed.In addition,based on the size of the structure,the appropriate
number of additional credits are checked as chosen by the permit applicant.
Authorized Representative Date
All Climate Zones
R-Value U-Factor''
Fenestration U-Factor° n/a 0.30
Skylight U-Factor n/a 0.50
Glazed Fenestration SHGC°" n/a n/a
Ceiling 49' 0.026
Wood Frame Wall"' 21 int 0.056
Mass Wall R-Value' 21/21" 0.056
Floor 309 0.029
Below Grade Wall" 10/15/21 int+TB 0.042
Slab°R-Value&Depth 10,2 ft n/a
*Table R402.1.1 and Table R402.1.3 Footnotes included on Page 2.
Each dwelling unit in one and two-family dwellings and townhouses,as defined in Section 101.2 of the International Residential Code shall comply with
sufficient options from Table R406.2 so as to achieve the following minimum number of credits:
❑ Small Dwelling Unit: 0.5 points
Dwelling units less than 1500 square feet in conditioned floor area with less than 300 square feet of fenestration area. Additions to existing building that
are less than 750 square feet of heated floor area.
C7t.Medium Dwelling Unit: 1.5 points
Idl All dwelling units that are not included in#1 or#3,including additions over 750 square feet.
I.Large Dwelling Unit: 2.5 points
Dwelling units exceeding 5000 square feet of conditioned floor area.
Table R406.2 Summary
Option Description Credit(s)
1a Efficient Building Envelope 1a 0.5 0.5
11b Efficient Building Envelope 1b 1.0
1c Efficient Building Envelope 1c 2.0
2a Air Leakage Control and Efficient Ventilation 2a 0.5
21b Air Leakage Control and Efficient Ventilation 21b 1.0
2c Air Leakage Control and Efficient Ventilation 2c 1.5
3a High Efficiency HVAC 3a 0.5
31b High Efficiency HVAC 3b 1.0 1.0
3c High Efficiency HVAC 3c 2.0
3d High Efficiency HVAC 3d 1.0
4 High Efficiency HVAC Distribution System 1.0
5a Efficient Water Heating 0.5
5b Efficient Water Heating 1.5
6 1 Renewable Electric Energy 0.5 1200wrl 0.0
Total Credits 1.50
*Please refer to Table R406.2 for complete option descriptions
http://www.energy.wsu.edu/Documents/2012%2ORes%2OEnergy.pdf
Table R402.1.1 Footnotes
For SI: 1 foot.= 304.8 mm, ci .=continuous insulation, int.= intermediate framing.
e R-values are minimums. U-factors and SHGC are maximums. When insulation is installed in a cavity which is less than the label
or design thickness of the insulation,the compressed R-value of the insulation from Appendix Table A101.4 shall not be less
than the R-value specified in the table.
b The fenestration U-factor column excludes skylights.The SHGC column applies to all glazed fenestration. Exception: Skylights
may be excluded from glazed fenestration SHGC requirements in Climate Zones 1 through 3 where the SHGC for such skylights
does not exceed 0.30.
"10/15/21.+TB" means R-10 continuous insulation on the exterior of the wall, or R-15 on the continuous insulation on the
interior of the wall, or R-21 cavity insulation plus a thermal break between the slab and the basement wall at the interior of the
basement wall. "10/15/21.+TB" shall be permitted to be met with R-13 cavity insulation on the interior of the basement wall
plus R-5 continuous insulation on the interior or exterior of the wall. "10/13" means R-10 continuous insulation on the interior
or exterior of the home or R-13 cavity insulation at the interior of the basement wall. "TB" means thermal break between floor
slab and basement wall.
d R-10 continuous insulation is required under heated slab on grade floors. See R402.2.9.1.
e There are no SHGC requirements in the Marine Zone.
f Basement wall insulation is not required in warm-humid locations as defined by Figure R301.1 and Table R301.1.
9 Reserved.
h First value is cavity insulation, second is continuous insulation or insulated siding, so "13.+5" means R-13 cavity insulation
plus R-5 continuous insulation or insulated siding. If structural sheathing covers 40 percent or less of the exterior, continuous
insulation R-value shall be permitted to be reduced by no more than R-3 in the locations where structural sheathing is used to
maintain a consistent total sheathing thickness.
1 The second R-value applies when more than half the insulation is on the interior of the mass wall.
J For single rafter-or joist-vaulted ceilings, the insulation may be reduced to R-38.
k Int. (intermediate framing) denotes standard framing 16 inches on center with headers insulated with a minimum of R-10
insulation.
• 1 Log and solid timber walls with a minimum average thickness of 3.5 inches are exempt from this insulation requirement.
Table R402.1.3 Footnote
a Nonfenestration U-factors shall be obtained from measurement, calculation or an approved source or as specified in Section
R402.1.3.
BRACED WALL LINE CALCULATIONS
BWL A BASED ON WIND(100 MPH): BWL 2 BASED ON WIND(100 MPH):
BWL SPACING=25 =3.0' BWL SPACING=24' =4.80'
FACTORS: FACTORS:
EXPOSURE D: 1.50 EXPOSURE D: 1.50
RIDGE HEIGHT=10': 1.00 RIDGE HEIGHT=10': 1.00
WALL HEIGHT=8': 0.90 WALL HEIGHT=8': 0.90
#BWL=3: 1.30 #BWL=2: 1.00
INTERIOR GWB: 1.00 INTERIOR GWB: 1_00
TOTAL FACTOR: 1.76 TOTAL FACTOR: 1.35
TOTAL BWP=3.0"1.76 =5.28' TOTAL BWP=4.80-1.35 =6.48'
BASED ON SDC(D2) BASED ON SDC(D2)
BWL LENGTH=61' =12.91' BWL LENGTH=35' =7.45'
FACTORS: FACTORS:
STORY HEIGHT=8': 1.00 STORY HEIGHT=8': 1.00
BWL SPACING=25': 1.20 BWL SPACING=24': 1.00
WALL DEAD LOAD=<15 PSF: 1.00 WALL DEAD LOAD=<15 PSF: 1.00
ROOF/CEILING DEAD LOAD=<15 PSF(ROOF ONLY): 1.00 ROOF/CEILING DEAD LOAD=<15 PSF(ROOF ONLY): 1.00
INTERIOR GWB: 1.00 INTERIOR GWB: 1.00
TOTAL FACTOR: 1.00 TOTAL FACTOR: 1.00
TOTAL BWP=12.91'•1.20 =15.49' TOTAL BWP=7.45''1.00 =7.45' j
BWL B BASED ON WIND(100 MPH): BWL 3 BASED ON WIND(100 Mn 1
BWL SPACING=25' =3.0' BWL SPACING=24' =4.80'
FACTORS: FACTORS:
EXPOSURE D: 1.50 EXPOSURE D: 1.50
RIDGE HEIGHT=10': 1.00 RIDGE HEIGHT=19: 1.00
WALL HEIGHT=8': 0.90 WALL HEIGHT=8': 0.90
#BWL=3: 1.30 #BWL=2: 1.00
INTERIOR GWB: 1.00 INTERIOR GWB: 1.00
TOTAL FACTOR: 1.76 TOTAL FACTOR: 1.35
TOTAL BWP=3.0-1.76 =5.28' TOTAL BWP=4.80-1.35 =6.48'
BASED ON SDC(D2) BASED ON SDC(D2)
BWL LENGTH=48' =10.18' BWL LENGTH=35' =7.45
FACTORS: FACTORS:
STORY HEIGHT=8': 1.00 STORY HEIGHT=8': 1.00
BWL SPACING=25: 1.20 BWL SPACING=24': 1.00
• WALL DEAD LOAD=<15 PSF: 1.00 WALL DEAD LOAD=<15 PSF: 1.00
ROOF/CEILING DEAD LOAD=<15 PSF(ROOF ONLY): 1.00 ROOF/CEILING DEAD LOAD=<15 PSF(ROOF ONLY): 1.00
INTERIOR GWB: 1_00 INTERIOR GWB: 1.00
TOTAL FACTOR: 1.00 TOTAL FACTOR: 1.00
TOTAL BWP=10.18"1.20 =12.22' TOTAL BWP=7.45"1.00 =7.45'
BWL C BASED ON WIND(100 MPH): BWL 4 BASED ON WIND(100 MPH):
BWL SPACING=25 =3.0' BWL SPACING=35' =6.75'
FACTORS: FACTORS:
EXPOSURE D: 1.50 EXPOSURE D: 1.50
RIDGE HEIGHT=10': 1.00 RIDGE HEIGHT=10': 1.00
WALL HEIGHT=8': 0.90 WALL HEIGHT=8': 0.90
#BWL=3: 1.30 #BWL=3: 1.30
INTERIOR GWB: 1.00 INTERIOR GWB: 1.00
TOTAL FACTOR: 1.76 TOTAL FACTOR: 1.76
TOTAL BWP=3.0"1.76 =5.26' TOTAL BWP=6.75"1.76 =11.88
BASED ON SDC(D2)
BASED ON SDC(D2) BWL LENGTH=30' =6.40'
BWL LENGTH=24' =5.14' FACTORS:
FACTORS: STORY HEIGHT=8': 1.00
STORY HEIGHT=8': 1.00 BWL SPACING=35': 1.40
BWL SPACING=25': 1.20 WALL DEAD LOAD=<15 PSF: 1.00
WALL DEAD LOAD=<15 PSF: 1.00 ROOF/CEILING DEAD LOAD=<15 PSF(ROOF ONLY): 1.00
ROOF/CEILING DEAD LOAD=<15 PSF(ROOF ONLY): 1.00 INTERIOR GWB: 1_00
INTERIOR GWB: 1.00 TOTAL FACTOR: 1.40
TOTAL FACTOR: 1.00 TOTAL BWP=6.40' 1.40 =8.96'
TOTAL BWP=5.14'•1.20 =6.17'
BWL'I BASED ON WIND(100 MPH): BWL 5 BASED ON WIND(100 Mn
BWL SPACING=4' =2.50' BWL SPACING=18' =3.70'
FACTORS: FACTORS:
EXPOSURE D: 1.50 EXPOSURE D: 1.50
RIDGE HEIGHT=10': 1.00 RIDGE HEIGHT=10': 1.00
WALL HEIGHT=8': 0.90 WALL HEIGHT=8': 0.90
#BWL=5: 1.60 #BWL=3: 1.30
INTERIOR GWB: 1_00 INTERIOR GWB: 1_00
TOTAL FACTOR: 2.16 TOTAL FACTOR: 1.76
TOTAL BWP=2.50-2.16 =5.40' TOTAL BWP=3.70-1.76 =6.51
BASED ON SDC(D2) BASED ON SDC(D2)
BWL LENGTH=19' =4.08' BWL LENGTH=30' =6.40'
FACTORS: FACTORS:
STORY HEIGHT=8': 1.00 STORY HEIGHT=8': 1.00
BWL SPACING=4': 1.00 BWL SPACING=18': 1.00
WALL DEAD LOAD=<15 PSF: 1.00 WALL DEAD LOAD=<15 PSF: 1.00
ROOF/CEILING DEAD LOAD=<15 PSF(ROOF ONLY): 1.00 ROOF/CEILING DEAD LOAD=<15 PSF(ROOF ONLY): 1.00
INTERIOR GWB: 1.00 INTERIOR GWB: 1.00
TOTAL FACTOR: 1.00 TOTAL FACTOR: 1.00
TOTAL BWP=4.08-1.00 =4.08 TOTAL BWP=6.40"1.00 =6.40'
Prescriptive Energy Code Compliance for All Climate Zones in Washington
Project Information Contact Information
Todd Spencer
T!A-d-Ala---- Upperleft Studios
ios.com 360-565-6269
This project will use the requirements of the Prescriptive Path below and Incorporate the
the minimum values listed.In addition,based on the size of the structure,the appropriate
number of additional credits are checked as chosen by the permit applicant.
Authorized Representative Date
All Climate Zones
R-Valuea U-Factor'
Fenestration U-Factor° n/a 0.30
Skylight U-Factor n/a 0.50
Glazed Fenestration SHGC" n/a n/a
Ceiling 49' 0.026
Wood Frame Wall,."' 21 int 0.056
Mass Wall R-Value' 21/21" 0.056
Floor 309 0.029
Below Grade Wall" 10/15/21 int+TB 0.042
Slab'R-Value&Depth 10,2 It n/a
'Table R402.1.1 and Table R402.1.3 Footnotes included on Page 2.
Each dwelling unit in one and two-family dwellings and townhouses,as defined In Section 101.2 of the International Residential Code shall comply with
sufficient options from Table R406.2 so as to achieve the following minimum number of credits:
F-1.Small Dwelling Unit: 0.5 points
Dwelling units less than 1500 square feet in conditioned floor area with less than 300 square feet of fenestration area. Additions to existing building that
are less than 750 square feet of heated floor area.
I77t.Medium Dwelling Unit: 1.5 points
ISI All dwelling units that are not included in#1 or#3,including additions over 750 square feet.
�.Large Dwelling Unit: 2.5 points
Dwelling units exceeding 5000 square feet of conditioned floor area.
Table R406.2 Summary
Option Description Credit(s)
1a Efficient Building Envelope 1a 0.5 0.5
1b Efficient Building Envelope 1b 1.0
1c Efficient Building Envelope 1c 2.0
2a Air Leakage Control and Efficient Ventilation 2a 0.5
2b Air Leakage Control and Efficient Ventilation 21b 1.0
2c Air Leakage Control and Efficient Ventilation 2c 1.5
3a i High Efficiency HVAC 3a 0.5
3b High Efficiency HVAC 3b 1.0 1.0
3c High Efficiency HVAC 3c 2.0
3d High Efficiency HVAC 3d 1.0
4 High Efficiency HVAC Distribution System 1.0
5a Efficient Water Heating 0.5
5b Efficient Water Heating 1.5
61 Renewable Electric Energy 0.5 '1200 Rwri 0.0
Total Credits 1.50
*Please refer to Table R406.2 for complete option descriptions
http://www.energy.wsu.edu/Documents/2012%2ORes%2OEnergy.Pdf
I
Table R402.1.1 Footnotes
For SI: 1 foot.= 304.8 mm, ci .=continuous insulation, int.= intermediate framing.
a R-values are minimums. U-factors and SHGC are maximums.When insulation is installed in a cavity which is less than the label
or design thickness of the insulation,the compressed R-value of the insulation from Appendix Table All 01.4 shall not be less
than the R-value specified in the table.
b The fenestration U-factor column excludes skylights.The SHGC column applies to all glazed fenestration. Exception: Skylights
may be excluded from glazed fenestration SHGC requirements in Climate Zones 1 through 3 where the SHGC for such skylights
does not exceed 0.30.
"10/15/21.+TB" means R-10 continuous insulation on the exterior of the wall, or R-15 on the continuous insulation on the
interior of the wall, or R-21 cavity insulation plus a thermal break between the slab and the basement wall at the interior of the
basement wall. "10/15/21.+TB"shall be permitted to be met with R-13 cavity insulation on the interior of the basement wall
plus R-5 continuous insulation on the interior or exterior of the wall. "10/13" means R-10 continuous insulation on the interior
or exterior of the home or R-13 cavity insulation at the interior of the basement wall. "TB" means thermal break between floor
slab and basement wall.
d R-10 continuous insulation is required under heated slab on grade floors. See R402.2.9.1.
e There are no SHGC requirements in the Marine Zone.
f Basement wall insulation is not required in warm-humid locations as defined by Figure R301.1 and Table R301.1.
9 Reserved.
h First value is cavity insulation, second is continuous insulation or insulated siding,so"13.+5" means R-13 cavity insulation
plus R-5 continuous insulation or insulated siding. If structural sheathing covers 40 percent or less of the exterior,continuous
insulation R-value shall be permitted to be reduced by no more than R-3 in the locations where structural sheathing is used to
maintain a consistent total sheathing thickness.
1 The second R-value applies when more than half the insulation is on the interior of the mass wall.
J For single rafter-or joist-vaulted ceilings,the insulation may be reduced to R-38.
k Int. (intermediate framing) denotes standard framing 16 inches on center with headers insulated with a minimum of R-10
insulation.
• Log and solid timber walls with a minimum average thickness of 3.5 inches are exempt from this insulation requirement.
Table R402.1.3 Footnote
a Nonfenestration U-factors shall be obtained from measurement,calculation or an approved source or as specified in Section
R402.1.3.