HomeMy WebLinkAbout1316 Morning Court Address:
1316 Morning Court
PREPARED 3/01/17, 8:24:12 INSPECTION TICKET PAGE 2
CITY OF PORT ANGELES INSPECTOR: JAMES LIERLY DATE 3/01/17
------------------------------------------------------------------------------------------------
ADDRESS . : 1316 MORNING CT SUBDIV:
CONTRACTOR GREEN CROW CONSTRUCTION LLC PHONE (360) 417-3661
OWNER GREEN CROW PROPERTIES INC PHONE
PARCEL 06-30-14-6-7-0480-0000-
APPL NUMBER: 16-00000921 RES NEW SFR
------------------------------------------------------------------------------------------------
PERMIT: BPR 00 BUILDING PERMIT - RESIDENTIAL
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
-—- --------—---------------— -- --' --------------'- -—--------------- -
BL1 01 8/15/16 JLL BLDG FOUNDATION FOOTING
8/15/16 AP August 15, 2016 9:12:45 AM jlierly.
Scott 775-4593
August 15, 2016 5:02:48 PM jlierly.
20 UFR installed/jll
BL2 01 8/19/16 JLL BLDG FOUNDATION STEM WALL
8/22/16 AP August 19, 2016 8:32:11 AM jlierly.
Wilson 670-8062
August 22, 2016 10:19:13 AM jlierly.
BFF 01 9/16/16 JLL BLDG FLOOR FRAMING
9/16/16 AP September 16, 2016 8:21:13 AM jlierly.
Derrick 461-8319
September 16, 2016 4:23:26 PM jlierly.
BL9 01 11/01/16 PB BLDG SHEARWALL
11/03/16 AP November 1, 2016 10:30:17 AM pbarthol.
Derik
November 3, 2016 4:11:52 PM pbarthol.
BAIR 01 12/02/16 - JLL BLDG AIR SEAL
12/02/16 AP December 2, 2016 8:42:51 AM jlierly.
Derrick 461-8319
December 2, 2016 4:48:08 PM jlierly.
BL3 01 12/02/16 JLL BLDG FRAMING
12/02/16 AP December 2, 2016 8:43:18 AM jlierly.
December 2, 2016 4:48:08 PM jlierly.
BLI 01 12/06/16 JLL BLDG INSULATION
12/21/16 AP December 6, 2016 2:01:26 PM jlierly.
Derrick 461-8319
December 21, 2016 4:06:45 PM jlierly.
PW99 01 2/28/17 RV PUBLIC WORKS FINAL -
2/28/17 AP February 28, 2017 9:36:23 AM rvess. ',
February 28, 2017 9:36:42 AM rvess.
BL99 01 3/01/17 JLL
` BLDG FINAL
March 1, 2017 8:17:55 AM jlierly.
Derick
------------------------------------------------------------------------------------------------
PERMIT: ME 00 MECHANICAL PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
-------------------------------------------------------------- -------------------------
ME1 01 12/02/16 JLL MECHANICAL ROUGH-IN
12/02/16 AP December 2, 2016 8:43:51 AM jlierly.
December 2, 2016 4:48:08 PM jlierly.
ME6 01 12/02/16 JLL MECHANICAL GAS LINE
12/02/16 AP December 2, 2016 8:43:38 AM jlierly.
December 2, 2016 4:48:08 PM jlierly.
ME99 01 _ 3/01/17 JLL MECHANICAL FINAL
----------------------------------- CONTINUED ONTO NEXT PAGE -----------------------------------
PREPARED 3/01/-17, 8:24:12 INSPECTION TICKET PAGE 3
CITY OF PORT ANGELES INSPECTOR: JAMES LIERLY DATE 3/01/17
------------------------------------------------------------------------------------------------
ADDRESS . : 1316 MORNING CT SUBDIV:
CONTRACTOR GREEN CROW CONSTRUCTION LLC PHONE (360) 417-3661
OWNER GREEN CROW PROPERTIES INC PHONE
PARCEL 06-30-14-6-7-0480-0000-
APPL NUMBER: 16-00000921 RES NEW SFR
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
--------------------- March 1, 2017 8 18:18 AM
- -------------------------------
PERMIT: PL 00 PLUMBING P IT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
PL2 01 8/24/16 PB PLUMBING ROUGH-IN
8/25/16 AP August 24, 2016 10:45:25 AM pbarthol.
Kurt 360-775-5450
August 25, 2016 1:50:29 PM pbarthol.
PL2 02 11/08/16 JLL PLUMBING ROUGH-IN
11/09/16 AP November 8, 2016 8:34:55 AM jlierly.
Jp 460-6902
November 9, 2016 10:14:51 AM jlierly.
PL99 01 3/01/17PLUMBING FINAL
March 1, 2017 8:18:31 AM jlierly.
------------------------- --------- COMMENTS AND NOTES --------------------------------------
CITY OF PORT ANGELES J
DEPARTMENT OF COMMUNITY & ECONOMIC DEVELOPMENT- BUILDING DIVISION
321 EAST 5TH STREET, PORT ANGELES, WA 9=62
Application Number . . . . Date 7/26/16
Application pin number 145
Property Address . . . . . . 1316 MORNING CT
ASSESSOR PARCEL NUMBER: 06-30-14-6-7-0480-0000- REPORT SALES TAX
Application type description RES NEW SFR
r Subdivision Name . . . . . . on your State excise tax form
Property Use
Property Zoning . . RS9 RESDNTL SINGLE FAMILY to the City of Port Angeles
Application valuation . . . . 156699 (Location Code 0502)
----------------------------------------------------------------------------
Application desc
new 1641 sfr w/ garage attached
--
------------------- ---------- - -----------------------------------------
Owner Contractor
------------------------ ------------------------
O GREEN CROW PROPERTIES INC GREEN CROW CONSTRUCTION LLC
PO BOX 2439 PO BOX 2439
PORT ANGELES WA 983620312 PORT ANGELES WA 98362
(3 60) 417-3661
----------------------------------------------------------------------------
�� Permit . . . . . . BUILDING PERMIT -RESIDENTIAL
Additional desc .
`�-- Permit Fee . . . . 1339.45 Plan Check Fee 870.64
Issue Date . . . . 7/26/16 Valuation . . . . 156699
Expiration Date 1/22/17
Qty Unit Charge Per Extension
BASE FEE 1020.25
57.00 5.6000 THOU BL-100,001-500K (5.60 PER K), 319.20
-----------------------------------------------------------------------------
Permit . . . . . . MECHANICAL PERMIT
Additional desc .
Permit Fee . . . . 167.35 Plan Check Fee .00
Issue Date . . . . 7/26/16 Valuation . . . . 0
Expiration Date 1/22/17
Qty Unit Charge Per Extension
BASE FEE 50.00
1.00 14.8000 EA ME-FURN/HP/FAU < OR = 5 TON 14.80
1.00 7.2500 EA I ME-VENT FAN (SINGLE DUCT) 7.25
1.00 10.6500 EA ME-HOOD/DUCT-MECH. EXHAUST 10.65
1.00 10.6500 EA ME-FUEL GAS PIPING,1-5 OUTLETS 10.65
5.00 14.8000 EA ME-HEATER(SUSP/WALL/FLOOR-MTD) 74.00
----------------------------------------------------------------------------
Permit . . . . . . PLUMBING PERMIT
Additional desc .
Permit Fee . . . . 195.00 Plan Check Fee .00
Issue Date . . . 7/26/16 Valuation . . . . 0
Expiration Date 1/22/17
Y
Qty Unit Charge Per Extension
w BASE FEE 50.00
v 10.00 7.0000 EA PL-PLUMBING TRAP 70.00
1.00 7.0000 EA PL-WATER LINE 7.00
Separate Permits are required forelectrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes
null and void if work or construction authorized isnot commenced within 180 days,if construction or work is suspended or abandoned
for a period of 180 days after the work has commenced, or if required inspections have not been requested within 180 days from the
last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions
of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does
not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construction.
7�( rt4 c Gil
Date Print Name Signature of Contractor or Authorize Agent Signature of Owner(if owner is builder)
T:Forms/Building Division/Building Permit
BUILDING PERMIT INSPECTION RECORD
- PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS-
Building Inspections 417-4815 Electrical Inspections 417-4735
Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886
IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED.
POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE.
Inspection Type Date Accepted By Comments
FOUNDATION:
Footings
Stemwall
Foundation Drainage/Downspouts
Piers
Post Holes(Pole Bldgs.)
PLUMBING:
Under Floor/Slab
Rough-in
Water Line Meter to Bldg)
Gas Line
Back Flow/Water
AIR SEAL:
Walls
Ceiling
FRAMING:
Joists/Girders/Under Floor
Shear Wall/Hold Downs
Walls/Roof/Ceiling
Drywall Interior Braced Panel Only)
T-Bar
INSULATION:
Slab
Wall/Floor/Ceiling
MECHANICAL:
Heat Pump/Furnace/FAU/Ducts
Rough-in
Gas Line
Wood Stove/Pellet/Chimney
Commercial Hood/Ducts
MANUFACTURED HOMES:
Footing/Slab
Blocking&Hold Downs
Skirting
PLANNING DEPT. Separate Permit#s SEPA:
Parkin /Lighting ESA:
Landscaping SHORELINE:
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE
Inspection Type Date Accepted By
Electrical 417-4735
Construction - R.W. PW /Engineering 417-4831 3 '
Fire 417-4653 _�y
Planning 417-4750
Building 417-4815
CITY OF PORT ANGELES
lr7v
DEPARTMENT OF COMMUNITY & ECONOMIC DEVELOPMENT- BUILDING DIVISION
321 EAST 5TH STREET, PORT ANGELES, WA 98362
Page 2
Application Number . . . . . 16-00000921 Date 7/26/16
Application pin number . . . 260145
REPORT SALES TAX
Qty Unit Charge Per Extension On our state excise tax form
5.00 7.0000 EA PL-DRAIN VENT PIPING 35.00 Y
1.00 15.0000 EA PL-SEWER LINE 15.00 to the City of Port Angeles
1.00 7.0000 EA PL-WATER HEATER 7.00
1.00 10.6500 EA PL-FUEL GAS PIPE, 1-5 OUTLETS 11.00 (Location Code 0502)
--------------------------------------------------------------------------
Special Notes and Comments
v June 24, 2016 10:04:37 AM tamiot.
ELECTRICAL SERVICE SHALL COME FROM THE EXISTING PEDESTAL
EAST OF THE TRANSFORMER IN THE SOUTH/WEST CORNER OF THE
PROPERTY.
July 25, 2016 4:31:41 PM pbarthol.
Project will result in a single story 2285sf SFR.
Lot coverage 16.7W. Site coverage 23W
Ditches & 8" culverts will be installed to City Standards.
See Public Works Engineering for Standards.
1. Establishing Construction Access.
2. Install sediment controls BMPs.
3. Stabilize exposed soils.
4. Protect slopes from erosion.
5. Protect drain inlets.
6. Control pollutants including but not limited to spills,
concrete wash out, exposed aggregate processes, concrete
_. grinding and saw cut waste water.
7. Maintain temporary and permanent erosion control BMPS = -•-•-- -
during project.
All disturbed area's on site not covered by new improvements
should meet the attached soil quality and depth standard.
Consider applying for the City Green Infrastructure Rebate
of up to $750.00 towards the materials to install rain
garden to control roof and driveway runoff. Also rebates
available for downspout disconnections.Contact Jonathan
Boehme at 360 417-4811
All construction work within the City right of way requires
a separate Right of Way Construction application to be
completed by the contractor and approved by Public Works
Engineering prior to the start of work. A pedestrian or
traffic control plan is to be submitted for approval with
the application as necessary.
Sanitary sewer connection inspection is required by
Public Works prior to back fill of ditch. 24 hour advance
notice is required. Public Works Inspection request line
417-4831
Trench safety per applicable laws. Temp erosion control and
surface restoration responsibility of applicant. Contact
City inspector prior to start of work @ 360 417-4831. No
attachment to sanitary sewer of stormwater roof leaders,
foundation drains, yard drains, or any other CSO
contribution is allowed.
The contractor making the connection to an existing water
Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes
null and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned
for a period of 180 days after the work has commenced, or if required inspections have not been requested within 180 days from the
last inspection. 1 hereby certify that I have read and examined this application and know the same to be true and correct. All provisions
of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does
not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construction.
Date Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder)
T:Forms/Building Division/Building Permit
BUILDING PERMIT INSPECTION RECORD
PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS-
Building Inspections 417-4815 Electrical Inspections 417-4735
Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886
IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED.
POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE.
Inspection Type Date Accepted By Comments
FOUNDATION:
Footings
Stemwall
Foundation Drainage/Downspouts
Piers
Post Holes(Pole Bldgs.)
PLUMBING:
Under Floor/Slab
Rough-in
Water Line Meter to Bldg)
Gas Line
Back Flow/Water
AIR SEAL:
Walls
Ceiling
FRAMING:
Joists/Girders/Under Floor
Shear Wall/Hold Downs
Walls/Roof/Ceilin
Drywall Interior Braced Panel Only)
T-Bar
INSULATION:
Slab
Wall/Floor/Ceiling
MECHANICAL:
Heat Pump/Furnace/FAU/Ducts
Rough-in
Gas Line
Wood Stove/Pellet/Chimney
Commercial Hood/Ducts
MANUFACTURED HOMES:
Footing/Slab
Blocking&Hold Downs
Skirting
PLANNING DEPT. Separate Permit#s SEPA:
Parkin /Lighting ESA:
Landscaping SHORELINE:
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE
Inspection Type Date Accepted By
Electrical 417-4735
Construction - R.W. PW /Engineering 417-4831
Fire 417-4653
Planning 417-4750
Building 417-4815
CITY OF PORT ANGELES
DEPARTMENT OF COMMUNITY & ECONOMIC DEVELOPMENT- BUILDING DIVISION
v. 321 EAST 5TH STREET, PORT ANGELES, WA 98362
Page 3
Application Number . . . . . 16-00000921 Date 7/26/16
Application pin number 260145
----------------------------------------------------------- REPORT SALES TAX
Y Special Notes and Comments ony our state excise tax form
meter is responsible to adjust water meter depth so that
there is a minimum of 4 to 6 inches of clearance between the to the City of Port Angeles '
bottom of the meter box lid and the top of the meter at
finish grade. (Location Code 0502)
Construct driveway and Sidewalks to City Standards.
Concrete with exposed aggregate or other non-standard
finishes(including colors or dyes)are not allowed in the
City road right of way. Broom finish only. An inspection by
Public Works Engineering is required prior to pouring
concrete. Public Works inspection request line 417-4831
----------------------------------------------------------------------------
""- Other Fees . . . . . . . . . SEWER SYSTEM DELV CHARGE 2260.00
STATE SURCHARGE 4.50
PW WATER SYSTEM USE FEE 2260.00
--------------------------------------=-------------------------------------
+� Fee summary Charged Paid Credited Due
-
=--------------- ---------- ---------- ---------- ----------
Permit Fee Total 1701.80 1701.80 .00 .00
Plan Check Total 870.64 870.64 .00 .00
Other Fee Total 4524.50 4524.50 .00 .00
Grand Total 7096.94 . 7096.94 .00 .00
Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes
null and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned
for a period of 180 days after the work has commenced, or if required inspections have not been requested within 180 days from the
last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions
of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of,a permit does
not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construction.
Date Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder)
T:Forms/Building Division/Building Permit
BUILDING PERMIT INSPECTION RECORD
— PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS
Building Inspections 417-4815 Electrical Inspections 417-4735
Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886
IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED.
POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE.
Inspection Type Date Accepted By Comments
FOUNDATION:
Footings
Stemwall
Foundation Drainage/Downspouts
Piers
Post Holes(Pole Bldgs.)
PLUMBING:
Under Floor/Slab
Rough-in
Water Line Meter to Bldg)
Gas Line
Back Flow/Water
AIR SEAL:
Walls
Ceiling
FRAMING:
Joists/Girders/Under Floor
Shear Wall/Hold Downs
Walls/Roof/Ceilin
Drywall Interior Braced Panel Only)
T-Bar
INSULATION:
Slab
Wall/Floor/Ceiling
MECHANICAL:
Heat Pump/Furnace/FAU/Ducts
Rough-in
Gas Line
Wood Stove/Pellet/Chimney
Commercial Hood/Ducts
MANUFACTURED HOMES:
Footing/Slab
Blocking&Hold Downs
Skirting
PLANNING DEPT. Separate Permit#s SEPA:
Parkin /Lighting ESA:
Landscaping SHORELINE:
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE
Inspection Type Date Accepted By
Electrical 417-4735
Construction - R.W. PW I Engineering 417-4831
Fire 417-4653
Planning 417-4750
Building 417-4815
THET� For City Use
CITY OF SORT NOL' ■ S,
Permit#
WASHI N G T o N, U. S. Date Received:
321E 5lh Street Date Approved
Port Angeles,WA 9836
P:360-417-4817 F:360-417-4711
Email:permitsOciWflia.us BUILDING PERMI PPLICATION
Project Address: 1316 Morning Court
Phone:360-417-3669
Prima Bruce Emery Contact: Email:bruce@greencrow.com
Name Green Crow Investments LLC phone 360-417-3669
Property Mailing Address Email
Owner P.O. Box 2439 bruce@greencrow.com
City Port Angeles State WA zip 98362
Name Greebn Crow Construction LLC Phone 360-417-3669
Contractor Address P.O. Box 2439 Email bruce@greencrow.com
Information City Port Angeles State WA zip 98362
Contractor License#GREENCC933CZ Exp.Date:3/7/2017
Legal Description: Zoning: Tax Parcel# Project Value: (materials and labor)
Lot 48, Riedell ll, Ph. 3, V15 P51 RS-9 063014-670480 $ 156,699
Residential 8 Commercial ❑ Industrial ❑ Public ❑
Permit Demolition ❑ Fire ❑ Repair ❑ Reroof(tear off/lay over) ❑
Classification For the following,fill out both pages of permit application:
(check New Construction 8 Exterior Remodel ❑ Addition ❑ Tenant Improvement ❑
appropriate) Mechanical El Plumbing ❑ Other 11Fire Sprinkler System Proposed Irrigation System Proposed or Proposed Bathrooms Proposed Bedrooms
or Existing? Yes 0 No D I Existing? Yes 0 No El 2 2
In addition to standard hard copy submittals please send a PDF copy of all Stormwater plans and Engineering to
www.stormwater@-cityofpa-us
Project Description Construct a 1,641 SF single family residence with attached garage
Is project in a Flood Zone: Yes ❑ No8 Flood Zone Type:
If in a Flood Zone, what is the value of the structure before proposed improvement? $
I have read and completed the application and know it to be true and correct. I am authorized to apply for
this permit and understand that it is my responsibility to determine what permits are required and to
obtain permits prior to work. I understand that plan review fees are not refundable after review has
occurred. I understand that I will forfeit review fees if I withdraw the application before the permit is
issued. I understand that if the permit is not picked up/issued within i8o days of submittal,the application
will be considered abandoned and the fees will be forfeited.
6/21/16 Bruce Emery
W�7ol J
Date Print Name Signature �"
Residential Structures
Existing Proposed Construction For Office Use
Area Descriptions(SQ FT) Floor area Floor area $Value new area
Basement
First Floor
1,641 139,485
Second Floor
Covered Deck/Porch/Entry 117 1,404
Deck(over 30"or 2" floor)
Garage 527 15,810
Carport
Other(describe)
Area Totals 2,285 156,699
Commercial Structures
Area Descriptions(SQ FT) Existing Proposed Construction For Office Use
Floor area Floor area $Value new area
Existing Structure(s)
Proposed Addition
Tenant Improvement?
Other work(describe)
Site Area Totals
Lot/Site Coverage Calculations
Lot Size (sq ft) Lot Coverage(sq ft)foot print of %Lot Coverage(Total lot cov-lot size) Max Bldg Height
13,678 1 all structures Z�, :457 sq ft 16.7% 117-4"
Site Coverage(Sq Ft of all impervious) %of Site Coverage(total site cov-lot size)
3,152 23.0 %
Mechanical Fixtures
Indicate how many of each type of fixture to be installed or relocated as part of this project.
Air Handler Size: O Haz/Non-Haz Piping Outlets:
Appliance Exhaust Fan # Heater(Suspended,Floor,Recessed wall) #
1 5
Boiler/Compressor Size: # Heating/Cooling appliance #
0 re air/alteration 0
Evaporative Cooler(attached,not # Pellet Stove/Wood-burning/Gas #
ortable) 0 Fireplace/Gas Stove/Gas Cook Stove/Misc. 0
Fuel Gas Piping 1 1#of Outlets: Ventilation Fan,single duct #
S
Foram/He t Pump/ Size: # Ventilation System #
EorcedAkljjjit 12,000 btu 1 0
Plumbing Fixtures
Indicate how many of each type of fixture to be installed or relocated
Plumbing Traps 0 Water Heater # 1
Plumbing Vent piping # Medical gas piping #of Outlets:
5 0
Water Line ,# Fuel gas piping #of Outlets: 1
Sewer Line # Industrial waste pretreatment
1 interceptor Grease Trap) Size
Other(describe):
T:\Forms\2015 CED Form Updates\Building&Permitting\BP\Building Permit 20150415.docx
U
A NIEW RESIDENCE FOR DESICsN LOADS a NOTES Z
DISCREPANCIES:
GREFIN (CROW PROPER=, Ema IN CASE OF D15CREPANCIES BETWEEN THE PLANS,
9 REFERENCED STANDARDS,AND GOVERNING CODES,THE MORE STRINGENT [x] C
T 7f 71��7I+ i�y�7ID ANGELES,
7C�+ REQUIREMENT SHALL GOVERN. ALL DISCREPANCIES SHALL BE BROUGHT TO
1Ldyy)L 48 MORNING (COURT,y PORT lill�(�p)L;�.ES, WA THE ATTENTION OF THE ARCHITECT AND ENGINEER PRIOR TO PROCEEDING E•-I b
WITH ANY WORK INVOLVED. :4
DESIGN LIVE LOADS: W H
ROOF 30 PSF(SNOW) O
FLOOR 40 PSF a
D�V A W I NCz INDEX: DESIGN DEAD LOADS: P E
ROOF15 PSF a0 ]
A-I SITE PLAN FLOOR 15PSF w
0
DESIGN WMD LOAD: W
,4-2 FOUNDATION PLAN BASIC WIND SPEED 100 MPH,EXPOSURE C W a z
14-3 FLOOR PLAN DESIGNSEISMICLOAD: A 0
CATEGORY D1 a
A-4 ROOF FRAU"ZINC. PLANW
SECTIOUND
N FOATIONS: wT
W a
DESIGN SOIL PRESSURE= 00 PSF(ASSUMED)
15
ALL FOOTINGS 514
ALL BE PLACED A MINIMUM OF 18"BELOW FINISHED GRADE Q s
A-5 EXTERIOR ELEVATIONS AND BEAR ON FIR1,UNDISTURBEDSOIL. LOWER FOOTINGS TO FIRM
BEARING IF SUITABLE SOIL 15 NOT FOUND AT MINIMUM FOOTING DEPTHS.
!al
IREATED WOOD: :y�
I ALL WOOD PLATES IN DIRECT CONTACT WITH CONCRETE,MASONRY,
EARTH,OR WITHIN EIGHT INCHES OF EARTH SHALL BE PRESSURE TREATED
IN ACCORDANCE WITH AWPB-FDN AND BEAR THAT QUALITY MARC. -,
PROVIDE TWD LAYER5 OF ASPHALT IMPREGNATED BUILDING PAPER
I SANITARY _ BETWEEN UNTREATED WOOD LEDGERS,BLOCKING,ETC AND CONCRETE,
I -
SELLER BiUBB MASONRY,OR EXTERIOR STEEL.
1 �_ _
/ 3
CONNECT31
SETBACK `S 78• - 4 9
TO STORI
I / .I mss\ _ _ 8
GOVERED
PORCH
DECK
4i I II S-4 a
I = I I WANALK
O t / 9
I U I P 'I // LOT 48
ASPHALT I I HOUSEDRIVEWA
I -,l
' I 7O'E 70'
CAI' NC.APRLN II
WATER
I GARAGE li
METER
_ A
GENERAL PROJECT NOTES:
POWER
ILi1L1T} PHONE 1 _' `_�JII / // D D�RaD)Ye ae:PaRneLL�DlduewndiE:axp oo xor xFtfmDReY bau au rpgnRw,
E45EIgNi CABLE - / cR rF,xTDs a raniRrilw TN:conRDciaR DNaLL w!¢mdu ne Ru ecaE L
_ / s, ,IE D]Rc d'D E,nL dLL[QCVFNI910 FIxER d5 d[pPtElEp PFURCi. � C-'
. S la•3T'pp �_ —� $�_ •p� v aL wRc lNRL ruraa+,D,wF roa RIETwdrlrauL RESIwnNL rnDE.'o.x,Lex cmE!oR GI
E 149.71, -�__ o C�7' coerExlD,w,.Lr�arsirwc rT`1
� __ // xD,Y.dLE DFmNt6 rFlai dLL eFWIOB N,If ffDD dm xD,RY dRCN,ECt q
_ lTfDldrtLi R iNi DD6EEE,YED. D FCj-xy-\i!
- - MECHANICAL NOTES:
BE_x&A—IC F:k4
AIC:k4 N N DY!/RWED lPdcED e)ID&YLL DE EOIPPEDiNM L
' C�CRpRAPt DUT4RS
),dLL IME&CD Dxut BE REEif PR05 WDx 9,CxiLDY P.RE,4u'IER
!,PRDrq[dqt DdP di DIDIWSiFR
® u Dqr prcER vgrt,D onlwE uCM d PUCu+LexD,x P N'D'. F—i
SITE PLAN NFDDED�ED,D�ED�DRPaI,INeEeEL.E+sDeDRP
BI N
e, „.11-
1 DE1EttoR!DRKL fEDEr.E DEIP PRRWRr PIIUFR Hqn RE Eulpvn tRUY wix
OCALEE•I" lo'_G°
NORTH
ABdFT
v PgOviDE BE WxD—T—b d,IW,ER N DRIP PM
I , .
y� (V
t `
�w x
y
` 9
�41
IRA #!, R
n
co
{F.
a �
M N
o '
M ,
rn
M � .
t
------ - - _= I
-----------
I
7— — —
4M PW I I
C —_
I—:
I'° rome'tawWAM I
`n"W
L J L J—,_,—,F7*., *."...
—,
ORMIL
36- 40-
16 C=F
l` D I•. to c steam .'..'. .. .. I .i . .. `ir•a ..-7.
�. � RYIi NPAN I@NLIICPtl WpR.. _
I I :, a m�r►�ee1m NBaR ue �'
II
I. I
— I ,., ' wc°"°aa'`+r�vw •.. I �
r— .
;— ----- II': II
'� � III � � I L.:.. ,, . :.. '•,, ;'• ,'` "I I
wnL� ,,,0J.
e'•e' e'•e' 6'-0' ��'O' i{18P TOTAL CRALLI/FQ:A
LMM
141 DIVIDED BY W.e SP NET VENT AMA REOID
16'x9°VENT.0!e EP a DNlM EY Oe3.1 VHNTe REO'D
1 V"eF m CN DRAM
ALL V"TO"A 6CFW*
LOT.tR MG
FLOOR PL,4N I �o'-a n"
NORTH
--�. .�.�.:,. __ ��_-...::.. � ,, A) � ��- w�m� Zi mpg�►� ��T� �
WbLZ a} 2s arch �'j� 3" PO-,V- WIT)' �7�mp5or� t77"rZ �
M.ampbon M.eAT14 Pdjr7 V2"1 A,Pi )o �Y,1v i�MlnvT.
i
�°
LO J iaNr� Sl w�p svr S�iT�j I�P
I --- E TD) 3`i F?O'X-- will-' Si`mJx,oN ' I�hl�1r✓ -5> Z°5
ONMG �� mow;lt -° PNh 51 m p5li►� sZ,p,
n�5U7445.5 li LAINDRY A
Atio
61
-5 �sirn��or� ° °°° s 2
tvdLL (� 1 b ps.,5 is-51753 BEDRXM
3 ;� BAtH
wA LL ,# ---- 3
. _
w
mom C6
-
wn� � Z
AWM
LOT Y FtG
FLOOR PL,4N
OCALS.vs^ , r-O^
NORTFI
Simple Heating System Size: Washington State
This heating system sizing calculator is based on the Prescriptive Requirements of the 2015 Washington State Energy Code(WSEC)and ACCA
Manuals J and S.This calculator will calculate heating loads only.ACCA procedures for sizing cooling systems should be used to determine cooling
loads.
The glazing(window)and door portion of this calculator assumes the installed glazing and door products have an area weighted average U-factor of
0.30. The incorporated insulation requirements are the minimum prescriptive amounts specified by the 2015 WSEC.
Please fill out all of the green drop-downs and boxes that are applicable to your project.As you make selections in the drop-downs for each section,
some values will be calculated for you. If you do not see the selection you need in the drop-down options,please call the WSU Energy Extension
Program at(360)956-2042 for assistance.
Project Information Contact Information
w
1316 Morning Court . .t Kurt Hansen .®
m' 7755450 JVA
JJVW.
Heating System Type: *All Other systems OHeat Pump
To see detailed instructions for each section,place your cursor on the word"Instructions".
Design Temperature
Instructions w....-
Port Angeles Design Temperature Difference(4T) 42
F�
AT=Indoor(70 degrees)-Outdoor Design Temp
Area of Building
Conditioned Floor Area
Instructions Conditioned Floor Area(sq ft) _ 1,641
Average Ceiling Height Conditioned Volume
Instructions Average Ceiling Height(ft) Ism, 9.0 14,769
Glazinq and Doors U-Factor X Area = UA
Instructions .
0.30 288 86.34
Skylights U-Factor X Area = UA
Instructions 0.50 -
Insulation
Attic U-Factor X Area = UA
Instructions 0.026 61;641, 42.67
Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA
Instructions
Select R-Value NO selection ---
Above Grade Walls(see Figure 1) U-Factor X Area UA
Instructions a 0.056 1611,287 1 72.07
R-21 Intermediate
Floors U-Factor X Area UA
Instructions
R-30 0.029 _1;641 . 47.59
��
Below Grade Walls(see Figure 1) U-Factor X Area UA
Instructions
Select R-value l-M No selection 0 ---
Slab Below Grade(see�oure 1) F-Factor XLen th UA
Instructions
Select conditioning No selection Ulm, ---
i im u
Slab on Grade(see Figure a F-Factor X Length UA
Instructions - NO Selection `'A
Select R-Value � ---
Location of Ducts
InstructionsDuDuct Leakage Coefficient
No cts,
1.00
Sum of UA 248.67
Envelope Heat Load 10,444 Btu/Hour
Figure 1. Sum ofUAXAT
Air Leakage Heat Load 6,699 Btu/Hour
Volume X 0.6 X AT X.018
AboveG de r Building Design Heat Load 17,143 Btu/Hour
Air Leakage+Envelope Heat Loss
Building and Duct Heat Load 17,143 Btu/Hour
Ducts in unconditioned space:Sum of Building Heat Loss X 1.10
Ducts in conditioned space:Sum of Building Heat Loss X 1
Maximum Heat Equipment Output 24,001 Btu/Hour
Building and Duct Heat Loss X 1.40 for Forced Air Furnace
Building and Duct Heat Loss X 1.25 for Heat Pump
(07/01/13)
Prescriptive Energy Code Compliance for All Climate Zones in Washington
Project Information Contact Information
1316 Morning Court Green CrovVProperties
Port Angeles WA, 98362 AWN E,", Kurt Hansen
� 360-775-5450 w
This project will use the requirements of the Prescriptive Path below and incorporate the
the minimum values listed. In addition, based on the size of the structure,the appropriate
number of additional credits are checked as chosen by the permit applicant.
Authorized Representative Date
All Climate Zones° w
R-Value U-Factor
Fenestration U-Factorb n/a 0.30
Skylight U-Factor n/a 0.50
Glazed Fenestration SHGCb,e n/a n/a
Ceiling 49' 0.026
Wood Frame Wall9,kJ 21 int 0.056
Mass Wall R-Value' 21/21h 0.056
Floor 309 0.029
Below Grade Wall°,k 10/15/21 int+TB 0.042
Slabd R-Value& Depth 10,2 ft n/a
"Table R402.1.1 and Table R402.1.3 Footnotes included on Page 2.
Each dwelling unit in one and two-family dwellings and townhouses,as defined in Section 101.2 of the
International Residential Code shall comply with sufficient options from Table R406.2 so as to achieve the
following minimum number of credits:
❑1.Small Dwelling Unit: 0.5 points
Dwelling units less than 1500 square feet in conditioned floor area with less than 300 square feet of fenestration
area. Additions to existing building that are less than 750 square feet of heated floor area.
P]2. Medium Dwelling Unit: 1.5 points
All dwelling units that are not included in#1 or#3, including additions over 750 square feet.
❑3. Large Dwelling Unit: 2.5 points
Dwelling units exceeding 5000 square feet of conditioned floor area.
❑4. Dwelling unit other than one and two-family dwellings and townhouses: Exempt
As defined in Section 101.2 of the International Residential Code
Table R406.2 Summary
Option Description Credit(s)
1a Efficient Building Envelope 1a 0.5 ❑
1 b Efficient Building Envelope lb 1.0 ❑
1c Efficient Building Envelope 1c 2.0 ❑
2a Air Leakage Control and Efficient Ventilation 2a 0.5 ❑
2b Air Leakage Control and Efficient Ventilation 2b 1.0 ❑
2c Air Leakage Control and Efficient Ventilation 2c 1.5 ❑
3a High Efficiency HVAC 3a 0.5 ❑
3b High Efficiency HVAC 3b 1.0 121 1.0
3c High Efficiency HVAC 3c 2.0 ❑
3d lHigh Efficiency HVAC 3d 1.0 ❑
4 High Efficiency HVAC Distribution System 1.0 ❑
5a Efficient Water Heating 0.5 0.5
5b Efficient Water Heating 1.5 ❑
6 Renewable Electric Energy 0.5 "1200 kwh 0.0
Total Credits 1.50
*Please refer to Table R406.2 for complete option descriptions
http:/Iwww.energy.wsu.edu/Documents/Table 406 2 Energy Credits 2012 WSEC pdf
FOUNDATION PHASE
COMPLIANCE REQUIRED INSPECTED APPROVED
❑ 1. Slab insulation R10 required ❑
a. Exterior
b. Interior—from top of slab—24" vertically or horizontally—2" nailer
allowed.
0 2. Radiant Slab Insulation R-10 required under entire slab. ❑
❑ 3. Thermal break(s)shall be placed in the slab between conditioned and unconditioned ❑
space checked below:
a. dwelling/garage
b. dwelling/connected space
c. slab edge and foundation wall
MECHANICAL AND PLUMBING PHASE
❑ 4. Exhaust ventilation shall be provided for each dwelling unit as follows: ❑
Location Minimum CFM Manufacturer CFM(A W.G.)
Intermittent/Continuous
Kitchen Fan 100 CFM /25 CFM KenMore Khs2040 300
Bathroom fan 50 CFM /20 CFM NuTone QTN110E 110
Bathroom fan 50 CFM /20 CFM NuTone QTN110EL 110
Bathroom fan 50 CFM /20 CFM
Laundry fan 50 CFM /20 CFM NuTone QTN110E 110
WHOLE HOUSE FAN — Continuous Operation
45 CFM (1 —3 bedrooms, <1500 SF)
60 CFM (2—4 bedrooms, <3,000 SF)
90 CFM (3—5 bedrooms, <4,500 SF)
Whole house fan required in all new houses/dwelling units and all additions> 500 square feet.
Whole house fan must be ultra-quiet and must be labeled "Whole House Ventilation".
W'5. Whole house fan: ;
Location: Laundry Sone Rating (.1 W. G.) 1.0
a. Whole house fan must be readily accessible and operating instructions provided to
occupant
b. Whole house fan shall be listed and labeled "for continuous use"
C. Whole house fan shall be labeled"Whole House Ventilation (see operating instructions)"
❑ 6. Mechanical exhaust fan ducts shall be >4" and property sized. ❑
❑ 7. Mechanical exhaust fan ducts shall be insulated to R-4 in unconditioned spaces. ❑
0 8. Mechanical fresh air ducts shall be insulated to R-4 in conditioned spaced. ❑
9. Heating system requirements will be met with the following: �0
,
Type of heat: Ductless Heat pump
6
Mfr. FuiNsu Model#Inside unit:AOUI2RLEC.Outside unit:AUURLF
Output 12,000 BTU Fuel Type elec. Efficiency rating (AFUE) HSPF 12.2
❑ 10. Supply and return air ducts shall have sealed joints and seams in unconditioned spaces. ❑
Tapes and mastics listed in accordance with UL181A or B—NO DUCT TAPE PERMITTED
❑ 11. HVAC plenums, supply, and return air ducts insulated to R-8. ❑
❑ 12. Water heaters shall have: ❑
a. Separate power, or gas shut-off
b. Non-compressible R-10 pad(electric in unheated spaces or on concrete floors)
c. Temperature setting of 120° F
FRAMING PHASE
❑ 13. Glazing efficiency required shall be Maximum U-factor= .30 ❑
L� 14. Window specifications:
Manufacturer U-Factor
MilGard Style Line(opening windows) .30
MilGard Style Line(Picture windows) .28
a---1-5. Skylight specifications—Maximum U-factor= .50 ❑
# of Skylights Manufacturer Area U-Factor
❑ 16. Windows and door air leakage measures shall be met as follows: ❑
a. Exterior joints sealed caulked, gasketed or weather stripped.
❑ 17. Insulation shall be placed in concealed places such as: ❑
a. Behind shower/tub
b. Behind partition studs/comers
❑ 18. Standard air leakage is complete and installed in the following: ❑
a. Between sole plate/subfloor
b. Wring/plumbing/duct register penetrations
c. Rim joists/mud sills (heated lower floors)
d. Partition stud penetrations
e. Around window/door frames
INSULATION PHASE
❑ 19. Exterior slab insulation shall be R-10 and approved for below grade use. ❑
❑ 20. Walls, including rim joists, shall be insulated to: ❑
o R-21 with Intermediate Framing—headers insulated with R-10
❑ 21. Interior below grade walls shall be insulated to: 0
o R-21 with an R-5 thermal break OR
o R-10 Rigid insulation on the exterior OR
o R-15 Rigid insulation on the interior
❑ 22. Skylight wall insulation equivalent to the wall R-values. ❑
7
❑ 23. Insulation baffles shall be placed in ceilings to maintain at least 1" ventilation space ❑
and extend 6"vertically above batts or 12" vertically above loose fill insulation.
❑ 24. Vapor retarders shall be installed toward the warm surface and required to be rated ❑
at 1 perm dry cup or less. Select one option for floors, walls and ceilings:
Floors: Plywood w/exterior g u OR Poly > 4 mil, OR Backed batts
Walls: Poly>4 mil, OR Face-stapled backed batts, OR aor Retarder Paint(Not PV
Ceilings: Not required where ventilation space> 12"above insulation.
If less than 12": Face stapled backed batts, OR Poly> 4 Mil, OR Vapor Retarder Paint(Not PVA)
FINAL PHASE
❑ 25. Envelop floors shall be insulated to R-30. 0
❑ 26. Ceilings with attic above shall be insulated to R49. ❑
❑ 27. Single rafter or joist vaulted ceilings shall be insulated to R-38. 0
❑ 28. Door systems shall meet: ❑
o U-value= .20(Metal insulated or fiberglass insulated only(wood doors do not meet this
u-value)
Door No. 1: Codel Fiberglass Front Door.20
Door No. 2: Codel Fiberglass Kitchen Door.20
One exempt door allowed, Door No. 3:
❑ 29. Fresh air shall be provided for each dwelling unit as follows, choose option: 0
❑-/Tested, screened, controllable, through wall port
N Vented window frames
C Integrated with Central Forced Air Furnace which delivers outside makeup air through
ducting system and requires furnace fan to be controlled by a timer set at 8 hours/day.
❑ 30. Fresh air shall be provided for each dwelling unit as follows: ❑
a. Each bedroom
b. Each recreation room
c. Overall living area
d. Other"habitable" rooms
❑ 31. Exposed foam insulation shall comply as follows: ❑
a. Protected w/metal or plastic flashing that extended below grade.
b. Be approved for subgrade, exterior use and properly installed.
❑ 32. Air flow between fresh air ports and whole house fan ensures by 1/2" undercut doors/grills. ❑
❑ 33. Loose fill insulation OK if maximum ceiling slope no >3:12 and there is > 30" clear 0
distance from top to bottom chord to underside of roof sheathing at the roof ridge.
❑ 34. 6 mil black poly ground cover, lapped 12"at joints. 0
❑ 35. Clearances shall meet listed, minimums between insulation and chimney. 0
❑ 36. Attic hatch insulated to ceiling R-value and weather stripped. ❑
❑ 37. Attic access shall have wood dam to retain loose fill insulation. 0
❑ 38. All exterior doors to be weather stripped. 0
❑ 39. Heat pump thermostat shall have programmable capability. ❑
8
❑ 40. Caulking is installed around light fixtures and flue penetrations. ❑
❑ 41. Service hot and cold water piping to be insulated to R-3 in unconditioned spaces. ❑
❑ 42. Service recirculation hot water piping shall be insulated per code. ❑
❑ 43. Supply ducts shall have volume dampers to balance the system. ❑
❑ 44. Programmable thermostat with a minimum 5—2 schedule for main HVAC system. ❑
❑ 45. Readily accessible, automatic or manual means provided to restrict or shut off heating ❑
input to each zone or floor.
❑ 46. Backup heat prohibits simultaneous operation of primary system. ❑
❑ 47. Spot exhaust fans to have timer, dehumidisat, or switch. ❑
❑ 48. Showers and lavatories shall limit floor to <2.5 gallons per minute. ❑
❑ 49. All fire places shall have: ❑
a. 6 sq. in. of combustion air supply duct with damper connected to fire box
b. Tight fitting ceramic glass or metal doors
c. Tight fitting flue damper
❑ 50. Solid fuel burning appliances shall have: ❑
a. Tight fitting ceramic glass or metal door
b. Outside combustion air source directly connected to fire box
c. Exceptions—see code.
❑ 51. Recessed lighting fixtures shall be IC rated and labeled under ASTM E328 with tested ❑
air leakage <2.0 CFM, no slots or holes in cans, caulked or sealed between can and ceiling.
❑ 52. Indoor lighting shall be 50%compact fluorescent(pin based, or screw)or T-8 ❑
or smaller lamps.
❑ 53. All outdoor lighting permanently mounted to a building shall be high efficacy, or have ❑
a motion sensor and photo daylight control.
9
Window, Skylight and Door Schedule
Project Information Contact Information
11316',Moming Court Kurt Hansenx
7.7575,450
k
Width Height
Ref. U-factor Qt. Feet Inch Feet Inch Area UA
Exempt Swinging Door(24 sq. ft. max.) Manuf 020 1 13 1"74167P 20.01 4.00
Exempt Glazed Fenestration (15 sq. ft. max.) Q , 0.0 0.00
Vertical Fenestration (Windows and doors)
Component Width Height
Description Ref. U-factor Qt. Feet Inch Feet Inch Area UA
Mil aid?S feline Pic. 4 Man-f 0'28.v 1 2 =. 6 012.01 3.36
Mil ard'%le;line SH �. Manuf 0.30 3 3 �_j U 5 ° 45.0 13.50
Mil and S yl&line Pic. ' Manuf 0.28 2 °' 3,,U 9A 5 ° 30.0 8.40
_m � Mil and Style line Pic.' R§W Manuf 0:28 3 3 a 6 ° 60.0 16.80
Mil ard;Style,line SH 30 Manuf 0' . 1 2 ° 6`' ° 12.0 3.60
Mil arafStl eEline HS �_ Manuf 030 1� 6 ° 4 ° 24.0 7.20
Mil and"Stl a 6e SH 210k, Manufi 0.30 ;1L 2 AM 4 6 9.0 2.70
w' Mil and S'le line HSANINS& Manufc 0.30 1.' 512 4 . 6 22.5 6.75
� �. Mil and Style line SGD Manuf 028 1 8 ° 6r 6 53.3 14.93
h
-M Fri0.0 0.00
n$ 0.0 0.00
0.0 0.00
�. 0.0 0.00
"t AN&Ly ,. TA 0.0 0.00
"- 0.0 0.00
r
MEW- • � 0.0 0.00
.a AL Am 0.0 0.00
_. �..
� . 0.0 0.00
filo} " sow" 0.0 0.00
a #
F g -, $ 0.0 0.00
b 0.0 0.00
, xIL 0.0 0.00
. ..,: . Aim, . 0.0 0.00
0.01 0.00
a 0.0 0.00
WA 0.0 0.00
- a 0.0 0.00
0.01 0.00
0.0 0.00
0.0 0.00
IWAYr. ; ,IN '' 0.0 0.00
P
0.0 0.00
I 0.0 0.00
M, w 0.0 0.00
0.0 0.00
p 0.0 0.00
a 0.0 0.00
a 0.0 0.00
0.0 0.00
°r uti - 0.0 0.00
0.0 .00
� t 0.0EO-00
Sum of Vertical Fenestration Area and UA 1 267.81 77.24
Vertical Fenestration Area Weighted U= UA/Area 0.29
Overhead Glazing (Skylights)
Component Width Height
Description Ref. U-factor Qt. Feet "°h Feet "0h Area UA
v ,.
0.01 0.00
a" INA IS 1001 IS0.0 0.00
Y= NEW 0.0 0.00
. owl;% is 0.0 0.00
` , 1-11010 E 0.0 0.00
0.01 0.00
Sum of Overhead Glazing Area and UA 1 0.01 0.00
Overhead Glazing Area Weighted U= UA/Area 1 0.00
Total Sum of Fenestration Area and UA (for heating system sizing calculations) 1 287.81 81.24
LIID13IF I L
4 _
A R C H I _ �$
319 s.peabody,suite bi port an eles wa 98362
360.452.6116/fax 360.452.7064 w_:;, .t .yer
P�o'ect: dmtO4.#pW L4r Pro'ect No.
Sjbiect L1411! BY:
Date: )\,A ;_:;Ip I Sheet of
i
LINDBER(f,8NUM
A R C H 1 - C T S-
319 S.Peabody,Smite B.,Port Angeles,WA 98362
360.452.6116/fax 360.4517064
contact(a?,lindarclLcorn/ww-w.lindarclr.corn
Project: Pra ectNo.
Subject: B
Date: ' '�•13t / •S et o
- r
SHEAR WALL SL 4MARY
W L H V V(L SW VH-WL/2 POST HOLD DOWN
�3 rJ Z r
Z311 —Orr.2
qv
• ��5 l�(ol 2�.$ ��' 0) tom
695 lv p 101 -" 1�bW Z-
b 6- 15'/ 511 5,0b :3'k x-50
2 . 3 I ll GvG pj:20 A
• � A � � `? � 252 ,, 3�J 5 �1r�¢ 3' �7"7"� �
-VALLOF1T)r1 FoaFoP-MSISBEARWAL
5"E4R UJ4LL �
2. MAXIMUM SNEAK = 200 P.L R
USE 1/2" 5NEATiN6 e ONE SIDE OF !!BALL. INIAIL ALL EDGES illi N 6j, NAIL
A o"
Of, EOR FRA. iNG, USE DF NO,2. PROVIDE i/2'' D!AMEiER AN:ICOR
BOLT a AT 4r^z„ f i IM C
/'} _ O.G. , IAXIMUi SP.4C�hG AI/` �!-!L_ y OuNVA"ION.
FOR TIE 11ni'I' I �:i A EAC. ! END .niF T-ii� �.J . 4` 1 �d-� /'i�i�'�I/� 1,
Kri. dam/ iI�� R I" Nj.
3. MAXIMUM SSI=AR a 2-0 F).L. .
4`iNG� !ALL. N. !L A D-
,i —
4, e 0.�. OR FRAMING: UaE DIF NO,2, ='ROVI�E 1!1'' DIAMETER A�G�OR
BOLTS 4T 32 O.G. 'AXIMUM GAGING 4 Ta!=E FOUNDATION.
FOR i iE DO�UJNS AT EAC-1k END OF T i-IE ,UALL, SEE �R,4 G'Si E4F �L,�N-
MAXIMUM SHEAR = 31S P.L.F.
USE 1/2'' 5HEATING - ONE 51DE OF 'ALL � r f
�, NAIL ALS E�i�E� lJi T N 8a
A.T 5" O.G. FOR- =R SSE DF NO2. PROVIDE /2" DIAMETER 4NC;40R
BOLTS rT 32" 0r�`, A- T�� c T
f -�- i , �.JND f- . ON.
FOR T I= ✓O 1N1 I �, �`! � 1D Gi I� e' , 5�� `1�CF�. 'I ��
MAXIMUM 5l--fE.4R = 3
i/l ✓Wt AT :s0, n!
4`'
' O �R , J,2. ' /!Di � � ,
f= E^: i'�I'
,fes i�7 t=,!/24" ��
sem': •, .0 sem'✓VJF`t / f-`.�' a.e'"y J' IN'
r-': XiMUM 5i-
E4�C_�g _
_iH 1/2" 5�4=_ (S-4I � :s+�'s� vi 6� `�� :.J.^— �., Ni,
'-� C.c.s. �'� —Kr-I�i N� Iry ✓,'� +~ I��✓ / L t :.e �—�.�' s:✓I
b Y r �� 1� ✓ _ 6r. i J
-'A�" %i.i'..-',ETER ER ACI iR 5 rO; -c -
0UND4Ti0N_ FOR TIEE '`.0
SEE FR.4^1!NGiS 'EAR FLANS.
i. MAXIMUM SMEAR = 5&0 .LF.
USEi/2" 5.!E ATING - ONE SIDE OF 114LL. N41L ALL EDGr=S WI HiCd. N41-IS
LT 3j'"j C.C: FCR FRAMING, USE 3X DF N0.2. DC!UBLE 5i OM FL>A T ES ARE
ANC�GR G!
r.-YE D1A iE ER ¢;NG GR ECLTti A 2�' C.'-, r iAXi"I'UM ar-ACING 4T jL E
FCUNDLTICN. SCR T IE CL LTE
u'E /L' S QA-;r�G - CNE vi ✓E OF LUALI N4 4L L �
tV�. Gii ;Go Nva'' G
� .; ! L:.
AT t i/2' C.G. S AGCsERE D. FCR FRLI INS USE 3X DF NG.2. -' CUBLE BCTTG
FSA Ev ARE REc�U Rte,., BCS THROUGH TlL-' A 4 ,G' !_-G
E Ui' ''CR ::G;
PRCVIDE S/E" DIAMETER ANGOR BCL TS :^T 20" G.G. ' IAX!MUr'' CFACING
LT THE FOUNDATION. FOR TIE DO!NNS AT EACH END OF N IE WALL,
SEE FRAMING/5PlEAR FLANS.
9. MAXIMUM SHEAR = 170 P.L.F.
USE 1/2" SHEATING - ONE SIDE OF WALL. NAIL ALL EDGES WITH IOd NAILS
AT 2" O.C. STAGGERED. FOR FRAMING, USE 3X DF NO2. DOUBLE BOTTOM
PLATES ARE REQUIRED, BOLT THROUGH BOTH PLATES WITH ANCHOR BOLTS.
PROVIDE 5/8" DIAMETER ANCHOR BOLTS AT IS" O.C. MAXIMUM SPACING
AT THE FOUNDATION. FOR TIE DOWNS AT EACH END OF THE WALL,
SEE FRAMING/SHEAR PLANS,
10. MAXIMUM SHEAR = 8l0 P.L.F.
USE 1/2" SHEATING - BOTH SIDES OF WALL. NAIL ALL EDGES WITH Sd NAILS
AT 3 1/2" O.G. STAGGERED. FOR FRAMING, USE 3X DF NO.2. DOUBLE BOTTOM
PLATES ARE REQUIRED, BOLT THROUGH BOTH PLATES WITH ANCHOR BOLTS.
PROVIDE 3/4" DIAMETER ANCHOR BOLTS AT 20" O.G. MAXIMUM SPACING
AT THE FOUNDATION. FOR TIE DOWNS AT EACH END OF THE WALL,
SEE FRAMING/SHEAR PLANS.
I1. MAXIMUM SHEAR = 980 P.L.F.
USE 1/2" SHEATING - BOTH SIDES OF WALL. NAIL ALL EDGES WITH 86 NAILS
AT 3" O.C. STAGGERED. FOR FRAMING, USE 3X DF NO.2. DOUBLE BOTTOM
PLATES ARE REQUIRED, BOLT THROUGH BOTH PLATES WITH ANCHOR BOLTS.
PROVIDE 3/4" DIAMETER ANCHOR BOLTS AT 18" O.C. MAXIMUM SPACING
AT THE FOUNDATION. FOR TIE DOWNS AT EACH END OF THE WALL,
SEE FRAMING/SHEAR PLANS.
12. MAXIMUM SHEAR = 1,200 P.L.F.
USE 1/2" SHEATING - BOTH SIDES OF WALL. NAIL ALL EDGES WITH IOd NAILS
AT 3" O.C. STAGGERED, FOR FRAMING, USE 3X DF NO.2. DOUBLE BOTTOM
PLATES ARE REQUIRED, BOLT THROUGH BOTH PLATES WITH ANCHOR BOLTS.
PROVIDE 3/4" DIAMETER ANCHOR BOLTS AT 14" O.G. MAXIMUM SPAGING
AT THE FOUNDATION. FOR TIE DOWNS AT EACH END OF THE WALL,
SEE FRAMING/SHEAR PLANS.
13, MAXIMUM SHEAR = 1,540 P.L.F.
USE 1/2" SHEATING - BOTH SIDES OF WALL. NAIL ALL EDGES WITH 10d NAILS
AT 2" O.G. STAGGERED. FOR FRAMING, USE 3X DF NO2. DOUBLE BOTTOM
PLATES ARE REQUIRED, BOLT THROUGH BOTH PLATES WITH ANCHOR BOLTS,
PROVIDE 3/4" DIAMETER ANCHOR BOLTS AT 11" O.G. MAXIMUM SPACING
AT THE FOUNDATION. FOR TIE DOWNS AT EACH END OF THE WALL,
SEE FRAMING/SHEAR PLANS.
14. MAXIMUM SHEAR = 1,140 P.L.F.
USE 5/8" SHEATING - BOTH SIDES OF WALL. NAIL ALL EDGES WITH lOd NAILS
AT 2" O.G. STAGGERED. FOR FRAMING, USE 3X DF NO2. DOUBLE BOTTOM
PLATES ARE REQUIRED, BOLT THROUGH BOTH PLATES WITH ANCHOR BOLTS.
PROVIDE 3/4" DIAMETER ANCHOR BOLTS AT 9" O.G. MAXIMUM SPACING
AT THE FOUNDATION. FOR TIE DOWNS AT EACH END OF THE WALL,
SEE FRAMING/SHEAR PLANS.
EDGE NAIL SHEATHING PLYWD ROOF SHEATHING FRAME BETWEEN TRUSSES &
TO TOP PLATE EXTEND WALL SHEATHING
BLOCK AROUND TRUSSES TO ROOF
& EDGE NAIL
0 0 0 0 0 0 0 0 0
/ I I \, III II •/ I I \
/ 10 01 \ I 1 10 of Io °I \
I 1 1 1 I 1 I I I 1
to ofto of I I •/ to of
to 11 11 of 1 to of
— o oL - - - 1-1—� _ Jo o __ � J1 --- 10 a - -
0 0 0 O 0 0 0 0 0 0 0 0
--- - - - -- - -�- -- — — —— ——— —
- -
I j I j \TRuss I j I j TRUSS
II II \ / II II
II II \ /� II 11
II II /\ II II
SHEAR WALL DETAIL
SCALE: 1 " = 1'-0" RFDET080.DWG
----------
PROVINF 1Od X 2 1/1
NAZI -i Al 6"
STAGGFRFN
NOLIBI F ? X 6 .`;f I INS ---- .1
FOR :3" POSTS
� 6
1
SINE VIEW FACE 'VFW
[K) UBLE U T U D
SCAI__E: 'I = 1' -0"
- ROOF EDGE NAILING
O
O
WALL EDGE NAILING - - -
AT TRUSS
PLYWOOD SHEATHING -
SEE SHEAR WALL SCHEDUI.-F--��
---- ----- TRUSS
WALL EDGE NAILING ----�.�
AT TRUSS
WALL EDGE NAILING - -
TO TOP PLATE
DBL. 2x6 TOP PI ATE -- --�
WALL// R00F D TA D
-- — — DI VIAIf\ Dr)OE- CLIC A TUINVI C D A kdC DCTME l-NI TI7I ICCL—Q V.
DOUBLE TOP
PLATE ° °
°i SIMPSON MSTA36 ° °
' STRAP FORM STUDS
ABOVE BEAM TO
BELOW 0 °
DOOR HEADER 0 °
CONTINUOUS FORM
°l SIDE WALL TO
SIDE WALL VERIFY
SEE FRAMING PLAN
(2) 2X STUDS °
AT EDGE OF DOOR
END OF DOOR OR WINDOW CENTER WALL SUPPORT
SHEAR WAE� @ HEADER
SCALE.
�b Wp L-L S
,O W,Ol
A ) M-e7 7-c,
Z
a'
WALL 'Z aoanMw 1 3�' OW- W1Q)J -27 Agp7": O6TJ b7 J ZIQTCHEN
z2
_ M.MlRlXm M.BATF► 0 otj r-7 '/2t1 A,P7
pc.�T- wc�� cj� tynpgaN IJhL�2
600 O
Polr- will-' �1`Mr otv ' lat7tl)�'--51xj2 �5
DMMG a CLOSET IIS Wo LANDRY ANO `71M p,�PON 2Z+
if
At,)&iv -t;r-1/165
!v u(o
An�p
5�� s1 rrt�SoN �° W° 2
w1�LL !� l b � bS«�r, -5b53 i eEDRooM �
-70-]
BBATH
LIVNG Q Re 9b6 ne
r----
= s
3
) •d �+ naa+ -
SP�, 7'' 14 g s
2033 L � r------i 7
---J
DEN
Cs.4RA�
t
'I37 —
_ _
W AIL � � 1 90'x70
CONC,IFlI011
VuQ & �-� �o
L�-
f=L
LOT 40 MC aofg ff � f
ACAL '�L Al�
NOIlTI.1
�.W giro
7—yf!RAD!
. _ - -- . — . — ,
+_., _ I
CWT)�iA,War
' roar Ada1oR -d� .
--- - L _ aoe;• I I r r
I— I �
in in I I - - - - - -
'24 _ _ _
a ar cart eTar•wa l V"AMN vert16 CMRAP
— . — —• — • — • — .I TIPICAL
--- - '8th.
7-7
ON=T@DeaRADe
6'•s- 20'x 7d
CM~
wALG
z - V-
r�A�I SPACE lMTM pry0 Atirus-
6'•6" 212'-O" hi841 V TOTAL.CRAWL AREA
841 DIVIDED DT 90"6 V NET VMT AREA AND �
441-V I61xb"VENT■On SP 6 DIVIDED BT 099"1 YM REQ'D
1 YWM BNOIW ON M"
ALL VM TO HAUL°SCREW
LOT 41 MG ® '
6C64Lts 1/4" • 1'-O• G-
NORZTI.1