PREPARED 3/26/15, 13:31:02 INSPECTION TICKET PAGE 5
CITY OF PORT ANGELES INSPECTOR: JAMES LIERLY DATE 3/26/15
------------------------------------------------------------------------------------------------
ADDRESS . : 139 W 2ND ST SUBDIV:
CONTRACTOR PELLET HEAT CO. PHONE (360) 457-4406
OWNER : JON & IANTHA FRAZER PHONE (360) 460-1071
PARCEL 06-30-00-0-0-3235-0000-
APPL NUMBER: 15-00000287 RES MECHANICAL PERMIT
------------------------------------------------------------------------------------------------
PERMIT: ME 00 MECHANICAL PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
---------------------—----- --------- - ----------------------------------
ME99 01 . 3/26/15 L MECHANICAL FINAL
March 26, 2015 9:37:43 AM pbarthol.
Fireplace insert
Mike 457-4406
-------------------------------------- COMMENTS AND NOTES ------------------------------
CITY OF PORT ANGELES
DEPARTMENT OF COMMUNITY & ECONOMIC DEVELOPMENT- BUILDING DIVISION
321 EAST 5TH STREET, PORT ANGELES, WA 98362
Application Number . . . . . 15-00000287 Date 3/25/15
Application pin number . . . 498618
Property Address . . . . . . 139 W 2ND ST
ASSESSOR PARCEL NUMBER: 06-30-00-0-0-3235-0000- REPORT SALES TAX
Application type description RES MECHANICAL PERMIT on your state excise tax form
SubdProperty
Name . . . . . . to the City of Port Angeles
Pro ert Use
Property Zoning . . . . . . (Location Code 0502)
Application valuation . . . . 3600
Application desc
GAS FIREPLACE INSERT AND TANK SET
----------------------------------------------------------------------------
Owner Contractor
JON & IANTHA FRAZER PELLET HEAT CO.
139 W 2ND ST 230C EAST 1ST ST
PORT ANGELES WA 98362 PORT ANGELES WA 98362
(360) 460-1071 (360) 457-4406
----------------------------------------------------------------------------
Permit . . . . . . MECHANICAL PERMIT
Additional desc . . GAS INSERT AND TANK SET
Permit Fee . . . . 121.30 Plan Check Fee .00
Issue Date . . . . 3/25/15 Valuation . . . . 0
Expiration Date 9/21/15
Qty Unit Charge Per Extension
BASE FEE 50.00
1.00 10.6500 EA ME-STOVE/FIREPLACE/MISC. APP, 10.65
1.00 10.6500 EA ME-FUEL GAS PIPING,1-5 OUTLETS 10.65
1.00 50.0000 HR ME-INSPECTION, MIN 1 HR 50.00
----------------------- ------ ------- -----
Special Notes and Comments
Per Washington State Code 51-51-315,
installation of Carbon Monoxide
detector(s) is required if you are W
installing or replacing a fuel burning
appliance (wood, pellet, gas)and must be
in place prior to the final inspection
of this permit. They are required to be
place directly outside of each sleeping
area and at least one on each floor of
the house.
-------------- ------- -------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit
--Permit Fee Total 121.30 121.30 .00 .00
Plan Check Total .00 .00 .00 .00
Grand Total 121.30 121.30 .00 .00
Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes
null and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned
for a period of 180 days after the work has commenced, or if required inspections have not been requested within 180 days from the
last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions
of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does
not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construction.
�4ate Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder)
T:Forms/Building Division/Building Permit
BUILDING PERMIT INSPECTION RECORD
PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS—
Building Inspections 417-4815 Electrical Inspections 417-4735
Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886
IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED.
POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE.
Inspection Type Date Accepted By Comments
FOUNDATION:
Footings
Stemwall
Foundation Drainage/Downspouts
Piers
Post Holes(Pole Bldgs.)
PLUMBING:
Under Floor/Slab
Rough-in
Water Line(Meter to Bldg)
Gas Line
Back Flow/Water FINAL Date Accepted b
AIR SEAL:
a Walls
Ceiling
FRAMING:
Joists/Girders/Under Floor
Shear Wall/Hold Downs
Walls/Roof/Ceiling
Drywall Interior Braced Panel Only)
T-Bar
INSULATION:
Slab
Wall/Floor/Ceiling
MECHANICAL:
Heat Pum /Furnace/FAU/Ducts
Rough-In
Gas Line
Wood Stove/Pellet/Chimney
Commercial Hood/Ducts FINAL Date Accepted b
MANUFACTURED HOMES:
Footing/Slab
Blocking&Hold Downs
Skirting
PLANNING DEPT. Separate Permit#s SEPA:
Parkin /Lighting ESA:
Landscaping SHORELINE:
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE
Inspection Type Date Accepted By
Electrical 417-4735
Construction- R.W. PW /Engineering 417-4831
Fire 417-4653
Planning 417-4750
Building 417-4815
T:Forms/Building Division/Building Permit
Mar, 18. 2015 11 : 15AM SPA SHOP & PHC No. 8743 - P. 1
BUILDING/PLUMBING/MECHANICAL PERMIT APPLICATION - SHORT FORM e
(To be used for projpcts that do not require plan review.)
Date Received, (
Permit#% _
City of Port Angeles Please print in ink, Date Apprdved
Attn: Building Permit Technician Approved by
321 E. 5" St Port Angeles,WA 98362
350-417-4815 fax: 3607417.4711 Credit card payments are accepted Mon'=Fri 8-5-pm (no American Express)
Hours: Mon through Fri 8—5 pm Cash &checks are accepted Mon-Thurs 8:30-4 pm & Fri 8:30-12:30 pm
EContacton: Phone: 7,� 6 Ger:
fvN Phone: D (00 - ® 7/
Property owner's mailing address:
/` g tip/ Ste-tit Lw'vor_kk.".Y
Contractor's business narne: P�/�t /�c�r �e�ePhone:or ro ert owner's name if he/she'is doin /overseeln the �d 6
Contractor's mailing address:.
'Z 3 o`e .: RS �r t, S" a Aet e
Contractor's L&I license number: Expiration date:
Project Address: . 3 9 L��s t- ,2 � /
Project Type: ra Residential. 0 Commercial _ p Indpst6ali EM'01646mily
rt
Mechanical Permit: (explain thepoiect)
Lf� TAS F!rC ela" x"01"I¢ Qftef Vg.. 1te+11'-�
LP TaNlc ZXAfSkA1.14-E/ 06Y FL,r re-// a45' .
Project Valuation $ .a;0 U�
I have read and completed this application and know it to be true and correct. I am authorized to apply for this permit
and understand that it is my responsibilityto determine what permits are required, and to obtain permits prior to
working on projects.
Date�3 -42 -/S Signature -
Print Name /27�ir,44 e-L c�r /�
Page 2 of 2
Address:
139 W 2nd Street
PREPARED 6/05/15, 10:20:19 INSPECTION TICKET PAGE 5
CITY OF PORT ANGELES INSPECTOR: JAMES LIERLY DATE 6/05/15
------ -----------------
ADDRESS . : 139 W 2ND ST SUBDIV:
CONTRACTOR POWER TRIP ENERGY CORP PHONE (360) 643-3080
OWNER JON & IANTHA FRAZER PHONE (360) 460-1071
PARCEL 06-30-00-0-0-3235-0000-
APPL NUMBER: 15-00000632 RES SOLAR PROJECT
------------------------------------------------------------------------------------------------
PERMIT: BSOL 00 BUILDING PERMIT - SOLAR
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
-------------------------- ------------------------------------------ --- ---
BL99 01 6/05/15 L BLDG FINAL
June 5, 2015 10:21:06 AM jlierly.
wi 460-1070
------------------------ ------------ COMMENTS AND NOTES --------------------------------------
PREPARED 4/23/15, 9:59:55 INSPECTION TICKET PAGE 2
CITY OF PORT ANGELES INSPECTOR: JAMES LIERLY DATE 4/23/15
------------------------------------------------------------------------------------------------
ADDRESS 139 W 2ND ST SUBDIV:
CONTRACTOR PELLET HEAT CO. PHONE (360) 457-4406
OWNER JON & IANTHA FRAZER PHONE (360) 460-1071
PARCEL 06-30-00-0-0-3235-0000-
APPL NUMBER: 15-00000287 RES MECHANICAL PERMIT
------------------------------------------------------------------------------------------------
PERMIT: ME 00 MECHANICAL PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
ME6 01 3/26/15 JLL MECHANICAL GAS LINE
3/26/15 AP April 23, 2015 10:02:00 AM jlierly.
ME99 01 4/23/15L MECHANICAL FINAL
April 23, 2015 10:03:09 AM jlierly.
John 460-1071
-------------------------------------- COMMENTS AND NOTES --------------------------------------
CITY OF PORT ANGELES
DEPARTMENT OF COMMUNITY & ECONOMIC DEVELOPMENT- BUILDING DIVISION o
321 EAST 5TH STREET, PORT ANGELES, WA 98362
t�
Application Number . . . . . 15-00000632 Date 6/04/15
Application pin number . . . 455000
Property Address . . . . . . 139 W 2ND ST
ASSESSOR PARCEL NUMBER: 06-30-00-0-0-3235-0000- REPORT SALES TAX
Application type description RES SOLAR PROJECT
Subdivision Name . . . . . . on your state excise tax form
Property Use . . . . . . . . to the City of Port Angeles
Property Zoning .
Application valuation . . . . 16573 (Location Code 0502)
----------------------------------------------------------------------------
Application desc
REWSIDENTIAL ROOF MOUNTED PV SOLAR ARRAY
----------------------------------------------------------------------------
Owner Contractor
JON & IANTHA FRAZER POWER TRIP ENERGY CORP
139 W 2ND ST 83 DENNY AVE
PORT ANGELES WA 98362 PORT TOWNSEND WA 98368
(360) 460-1071 (360) 643-3080
----------------------------------------------------------------------------
Permit . . . . . . BUILDING PERMIT - SOLAR
Additional desc . . GRID TIE ROOF MOUNTED PV
Permit Fee . . . . 130.00 Plan Check Fee 00
Issue Date . . . . 6/04/15 Valuation . . . . 16573
Expiration Date 12/01/15
Qty Unit Charge Per Extension
BASE FEE 130.00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due 1
Permit Fee Total 130.00 130.00 .00 .00
Plan Check Total .00 .00 .00 .00 S
Grand Total 130.00 130.00 .00 .00 s
T./
�L
Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes
null and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned
for a period of 180 days after the work has commenced, or if required inspections have not been requested within 180 days from the
last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions
of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does
not presume to give authority to violate or cancel the provisio s of any state or local law regulating construction or the performance of
construction.
ate Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder)
T:Forms/Building Division/Building Permit
BUILDING PERMIT INSPECTION RECORD
-- PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS—
Building Inspections 417-4815 Electrical Inspections 417-4735
Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886
IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED.
POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE.
Inspection Type Date Accepted By Comments
FOUNDATION:
Footings
Stemwall
Foundation Drainage/Downspouts
Piers
Post Holes(Pole Bldgs.)
PLUMBING:
Under Floor/Slab
Rough-In
Water Line Meter to Bldg)
Gas Line
Back Flow/Water FINAL Date Accepted b
AIR SEAL:
Walls
Ceiling
FRAMING:
Joists/Girders/Under Floor
Shear Wall/Hold Downs
Walls/Roof/Ceiling
Drywall Interior Braced Panel Only)
T-Bar
INSULATION:
Slab
Wall/Floor/Ceiling
MECHANICAL:
Heat Pum /Furnace/FAU/Ducts
Rough-In
Gas Line
Wood Stove/Pellet/Chimney
Commercial Hood/Ducts FINAL Date Accepted b
MANUFACTURED HOMES:
Footing/Slab
Blocking&Hold Downs
Skirting
PLANNING DEPT. Separate Permit#s SEPA:
Parkin /Lighting ESA:
Landscaping SHORELINE:
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE
Inspection Type Date Accepted By
Electrical 417-4735
Construction-R.W. PW I Engineering 417-4831
Fire 417-4653
Planning 417-4750
Building 417-4815
T:Forms/Building Division/Building Permit
r
r
For City Use
CITY OFi A\
� ELES _
T Permit# �Z`� ' �8 -2—
WASH f N G T O N. U. S. Date Received: Gv /'5-
321 E 50,Street Date Approved l_g • 3'
Port Angeles,WA 4836
P:360-417-4817 F:360-417-4711
Email:permitsOcitypba.us BUILDING PERMIT APPLICATION
Pro'ect Address: t 3 q \N E>— -Z ST f For—:1— Ao(, .t,C,s
Pewe: --TMP E"eP-44 f Ce-,- Phone: 3C,c,-6 3� c�c� oFf+tr 3r;oK5Z�y cu�
Prima Contact: .VcKt, Ft., t-wAC Email: TCKt4 T'�w t2z'FLi(�C 3�t.= ry .God
Name�ANTKA .-!om FA&fwfL Phone F10 '14&V- `J"q
Property Mailing-Address 'J D Email
Owner r-5 W 65 Z i•2500 FR/--t=1L+ &y t4AL-C 0P%
city?cP-:r /rtil(nt:L15rJ State W,4 Zip CIO-31f"
Name{' W 0 II�J P EN 1:-�&l t-f�. Phone��Ql 3 ?✓ U
Contractor Address AAE Email B1CN �'czwt'�TRt�'CN �C
Information city P�i T-Cwm s C Nt> state Vv 4 Zip
Contractors License. PGW EQ T L q3 if a ff Exp.Date: jt1 Z-0 t i7
Legal Description: lrt- It Zoning: Tax Parcel#66; 000- Project Value: (materials and labor)
gi,<:c�-3z 'TPA P QKD ov373500co Is l(oS�3-10
Residential ® Commercial ❑ Industrial ❑ Public ❑
Permit Demolition ❑ Fire ❑ Repair ❑ Reroof(tear off/lay over) ® Soy
Classification For the following fill out both Rages of permit alnnlication:
(check New Construction. ❑ Exterior Remodel ❑ Addition ❑ Tenant Improvement ❑
appropriate) Mechanical ❑ Plumbing ❑ Other ❑
Fire Sprinkler System? Irrigation System? Proposed Bathrooms Proposed Bedrooms
Yes Ci No UL Yes CI No M
Project Description bei JAouNTC b f 6jR-ib;' Tib b PVPnvtaVcLtR'tc:s -5oi4
Et-��t�t.cc
Is project in a Flood Zone: Yes ® NoR Flood Zone Type:
If in a Flood Zone, what is the value of the structure before proposed improvement? $
1 have read and completed the application and know it to be true and correct.I am authorized to apply for
this permit and understand that it is my responsibility to determine what permits are required and to
obtain permits prior to work. I understand that plan review fees are not refundable after review has
occurred. I understand that I will forfeit review fees if I withdraw the application before the permit is
issued. I understand that if the permit is not picked up/issued within i8o days of submittal,the application
will be considered abandoned and the fees will be forfeited.
q/�C/�o
Date Print Name Signature
j-
HTE
y APprv'd 3 r f
$130 Fee
Application and Checklist for Roof Mounted Residential Solar Panels
Project Information:
Property Owner
Name: :fo,4 �, T�AN IFik FRA'-zEg-
Project Address: I'Sq WEr5T- Z'JD -ST NXT At,�kvt-E5 Phone: 36.04-60 - JO T1
Contractor Name ��;,.,C� I±'�i I-Pacil Co Registration#ppW1M-jf_,?3/+QF,
Contractor Phone: 3�a
PV system iZcvf HvmPtL-5b C� ►b'tlED S.Z3 Kw Mfg/model#of major equip: Su,%&?'owL--9_.
description 1(o (40D jLU5; C7 Kw 1NJrv9;VI0K 37,7•WATT PV
awe�LONE)5PR.-6 np-TI_ r.V-1014irea .
Per WAC 51-51-2300,if the answer to the following questions is"yes"a building permit will be
issued for simple(10-15kw output) PV systems without further engineering.
Section M2302.2.1-Where solar panels are installed on roofs,the roof structure shall be deemed adequate to
support the load of the rooftop if all of the following are met:
Yes No
1. PV system is designed and proposed for a single family or detached accessory structure ❑
2. The photovoltaic panels and modules and supporting structure shall be constructed of ❑
noncombustible materials or fire-retardant treated wood equivalent to that required for the
roof construction. The installation shall meet the requirements of the International Fire Code
as amended by WA State. PV modules are listed and labeled with a fire classification in
accordance with UL 1703
3. The PV system is designed for the wind speed of the local area and will be installed per the
manufacturer's specifications.
4. The ground snow load does not exceed 70 pounds per square foot.The PV system is designed Dq ❑
for the wind speed of the local area,and will be installed per the manufacturer's specifications.
5. Total dead load of modules,supports, mountings, raceways and all other appurtenanc s wel h ❑
no more than four pounds per square foot.Enter total dead load of system(lbs/ft"). I� Qsf
6. Supports for solar modules are installed to spread the dead load across as many roof-framing ❑
members as needed to ensure that no point load exceeds fifty(50) pounds. Modules are
mounted no higher than 18"above the surface of the roofing to which they are affixed and do
not exceed the highest point of the roof unless approved by the local jurisdiction.
NOTE: If site inspection indicates a concern that the roof structure is not adequate to
support the PV module(s),engineering may be required prior to final of the permit.
As the property owner or authorized representative of the above listed property, I attest that all
information in this checklist is accurate to the best of my knowledge.
Applicant Signature: Date: 57/Z-I/
Applicant Name(Please Print): T_6_RtJ 5. Ft_EM IPP - / Fo-IA' l,t,P ENOA4-J
Relationship to Property Owner:
T:\BUILDING\APPLICATION FORMS\SOLAR PERMIT CHECKLIST.DOCx
s0( -
A�
-
Seo�J,c�e
AtAiC(
rn1AAJ 4 Y
� A � o") ria
q tll�� 4914 51,
PwI4 4T(e,,�, V,�j
Zoo—z*o F93 6 2-
360 -4160,
V
SUNPOWER OFFERS THE BEST COMBINED POWER AND PRODUCT WARRANTY
POWER WARRANTY PRODUCT WARRANTY
N
IY�y,
y/�
v'acrs dear.,
More guaranteed power:95%for first 5 years, sQ ¢ Combined Power and Product defect 25 year coverage
-0.4%/yr.to year 25.8 that includ s panel replacement costs.
S'T'EM S 3 �
ELECTRICAL DATA OPERATING CONDITION AND MECHANICAL DATA
E20-327 E19-320 Temperature -40aF to+185aF(-40°C to+85°C)
Nominal Power12(Pnom) 327 W 320 W Max load Wind:50 psf, 400 Pa,245 kg/m2 front&back
Power Tolerance +5/-0%a +5/-0% Snow: 112 psf 400 Pa,550 kg/m2 front
Avg. Panel Efficiency13 20.4% 19.8% Impact resistance 1 inch (25mm)diameter hail at 52 mph(23 m/s).
Rated Voltage(Vmpp) 54.7 V 54.7 V Appearance Class A
Rated Current(Impp) 5.98 A 5.86 A Solar Cells 96 Monocrystalline Maxeon Gen II
Open-Circuit Voltage(Voc) 64.9 V 64.8 V Tempered Glass High transmission tempered Anti-Reflective
Short-Circuit Current(Isc) 6.46 A 6.24 A Junction Box IP-65 Rated
Max. System Voltage 600 V UL& 1000 V IEC Connectors MC4 Compatible Connectors
Frame Class 1 black anodized(highest AAMA rating)
Maximum Series Fuse 15 A
Power Temp Coef. -0.38%/°C Weight 41 lbs(18.6 kg)
:V-Te K Z
Voltage Temp Coef. -176.6 mV/°C TESTS AND CERTIFICATIONS
Current Temp Coef. 3.5 mA/aC Standard tests UL1703 (Type 2 fire Rating IEC 61215, IEC 61730
REFERENCES: Quality tests ISO 9001:2008, ISO 14001:2004
1 All comparisons are SPR-E20327 vs.a representative conventional panel:250W, EHS Compliance RoHS,OHSAS 18001:2007,lead free
approx. 1.6 m2, 15.3%efficiency. Ammonia test IEC 62716
2 PVEvolution Labs"SunPower Shading Study,"Feb 2013. Salt Spray test IEC 61701 (passed maximum severity)
3 Typically 7-95%more energy per watt, BEW/DNV Engineering "SunPower Yield to
Report,"Jan 2013. PID test Potential-Induced Degradation free: l 000V
10
SunPower 0.25%/yr degradation vs. 1.09'./yr conv. panel. Campeau, Z. et al. Available listings UL,CEC,CSA,TUV,JET, KEMCO,MCS,FSEC
"SunPower Module Degradation Rate," SunPower white paper,Feb 2013;Jordan,
Dirk"SunPower Test Report,"NREL,Oct 2012.
5"SunPower Module 40-Year Useful Life"SunPower white paper,Feb 2013.Useful
life is 99 out of 100 panels operating at more than 70%.of rated power.
6 Second highest, after SunPower XSeries, of over 3,200 silicon solar panels,
Photon Module Survey,Feb 2014. 1046 mm
7 8%more energy than the average of the top 10 panel companies Rested in 2012 [41.2 in]
(151 panels, 102 companies),Photon International,Feb 2013.
8 Compared with the top 15 manufacturers. SunPower Warranty Review, Feb
2013.
9 Some exclusions apply.See warranty for details.
10 5 of top 8 panel manufacturers from 2013 report were tested, 3 additional 46 mm ►{ j__ 1559 mm------�
silicon solar panels for the 2014. Ferrara, C., et al. "Fraunhofer PV Durability [1.S in] f [61.4inl
Initiative for Solar Modules:Part 2".Photovoltaics International,77-85. 2014.
11 Compared with the non-stress-tested control panel. Atlas 25+ Durability test
report, Feb 2013.from 2013 report were tested, 3 additional silicon solar panels
for the 2014. Ferrara, C., et al. "Fraunhofer PV Durability Initiative for Solar
Modules:Part 2".Photovoltaics International,77-85. 2014.
12 Standard Test Conditions(1000 W/m2 irradiance,AM 1.5,25°C).
13 Based on overage of measured power values during production
See hitp://www.sunpower.com/facts for more reference information.
For more details,see extended datosheet:www.sunpower.com/datashests.Read safety and installation instructions before using this product, www.sunpower.com
®December 2014 SunPower Corporation.All rights reserved.SUNPOWER,the SUNPOWER logo,MAXEON,MORE ENERGY,FOR LIFE.,and SIGNATURE are trademarks or registered Document#504860 li v D/LTR_US
trademarks of SunPower Corporation.Specifications included in this dotasheet are subject to change without notice.
SUNPOWER
HIGH PERFORMANCE & EXCELLENT DURABILITY
x�
�Jr
• 20.4%efficiency
Ideal for roofs where space is at a premium
or where future expansion might be E20 327 PANEL
needed.
• High performance HIGH EFFICIENCY"
Delivers excellent performance in real world Generate more energyr square foot
conditions, such as high temperatures, � q
clouds and low light.'-2,1 E-Series residential panels convert more sunlight to electricity producing
36% more power per panel,' and 60% more energy per square foot
• Proven value over 25 years.3,4
Designed for residential rooftops, E-Series
panels deliver the features, value and HIGH ENERGY PRODUCTION'
performance for any home. Produce more energy per rated watt
High year one performance delivers 7-9%more energy per rated watt.-
This advantage increases over time, producing 20% more energy over
the first 25 years to meet your needs.°
6 120,0
More Energy
110% er Roie `Fort
c
MaxeonO Solar Cells:Fundamentally better. �°� t 00%� w y
Engineered for performance,designed for durability. o qpo, 1 35' more.
I year 25
Engineered for peace of mind
m
Designed to deliver consistent, trouble-freeLU
7p°'° -
energy over a very long lifetime.4.5 y 60%
r
Designed for dura6ilityN sown
o s 10 i s 20 2s
The SunPower Maxeon Solar Cell is the Years
only cell built on a solid copper foundation. 0 10%
Virtually impervious to the corrosion and 3 i g o`- FF
i Maintains High �
Power at High Temps
cracking that degrade Conventional 8% i
Panels-',' o I No Light-Induced PHOTON
a 6% Oegrodation riL^r4
#1 Ranked in Fraunhofer durability test.10 '
� � _ -{ High Average Watts
Q
100% power maintained in Atlas 25+ 4% Better Low-Light and
comprehensive PVDI Durability test." Spectral Response
2 F
High-Performance
6 € Anti-Reflective Glass
} 0%
www.sunpower.com
Friday,January 31,2014
Snap rack-
SnapNrack
No r m a n 775 Fiero Lane,Suite 200
San Luis Obispo,CA 93401
"Series 100 Roof Mount'Cover Letter
3cheel
To Whom It May Concern,
We have performed calculations for the 100 series roof mount PV system based on
Structural the information provided by SnapNrack. Included with this letter are the report and
calculations. We did the calculations in accordance with the 2012 IBC,ASCE 7-10,
2012 NDS, and guidelines stated in the Solar America Board for Codes and
Standards.
nd
JUJn gin e e r Some of the components in the SnapNrack test data were used to determine the
capacity and section properties of materials. We collected the test data using the
5022 Sunrise Blvd. procedures outlined in the 2012 IBC Chapter 17.
Fair Oaks,CA 95628
(916)536-9585
(916)536-0260(fax) We included the following types of load combinations and building parameters into
our calculations:
1989-2013
24 years of e-rcellence , ASCE 7-10 wind speeds from 110 mph to 190 for B and C exposure
categories
• ASCE 7-10 Seismic Design Category E
• ASCE 7-10 Snow Loads up to 120 psf ground snow
• Buildings with mean roof heights up to 60 foot tilt angles / roof pitches
Norman Scheel,S.E. from 0 degrees to 60 degrees.
LEED AP BD+C
LEED AP Homes The calculations have also been completed in accordance with the 2006 IBC,2009
Fellow—SEAOC IBC, and ASCE 7-05. To use the data contained in this packet for projects that are
Fellow-ASCE
E-mail:norm(aasse-com being evaluated to the older ASCE 7-05 wind speeds,refer to Appendix A for a
wind speed conversion chart. Find the ASCE 7-05 (IBC 2006/2009)wind speed in
Rob Coon
General Manager the Chart in Appendix A,identify the corresponding ASCE 7-10(IBC 2012)wind
E-mail:rohcoan0nsse.com speed value,and proceed with using the charts contained in this packet with the
Steve Smith P.E. adjusted wind speed value.
Project Manager
E-mail:stevesmith(a-mssc.com In our opinion, the mounting system, outlined by SnapNrack Series 100 PV
Mounting System Code Compliance Installation Manual, is acceptable and meets
Steven Cooksey the loading requirements as stated above. See the report and calculations included
CAD Supervisor
E-mail:stcvc(a'•nsse.com with this letter for more information.
•?L,
If there are any further questions,please contact Norm Scheel. ''
Jackie Winslow
Office Manager
E-mail:jackic a-nssc.com Norman Scheel PE, SE -
LEED-AP BD+C,LEED-AP Homes
Fellow S OC
Fellow C.E.
id0.282 !'
EXPIRES DE'EMBER 26, ZVkn
n�SnapNrack Series 100
*' ac
Project Info:
Dealer: Power Trip Energy_ Project Name: Frazer
Create Date: 2015-05-29T11:09:57-0700 BOM#: 32127
PV Module Data:
Module BrandSunPower Length 61.39 inches
Modell SPR-327NE-WHT-D Width 41.18 inches
Depth 1.81 inches
Environmental Requirements: Weight 41.00 pounds
Topographic Condition Standard Rated power @ STC 327.00 W
Standard IBC 2012 Rail Color' Black
Item 4
Snow Load 21-30 psf checklist Racking Color Clear
item 4
Wind Speed 130 mph checklist
Rafter Spacing 24 inches
Roof Attachment Flashed L-Foot
System Style:
Rail Finish Black Anodized
End Clamp Type Universal
Grounding Method UL 2703 Listed item 2 checklist
Micro Attachment Kits No
Edge Screen Trim? No I if"Yes",4"or 8"screen? Screen Height inches
Tilt Up?J No
Sub-Arrays: UL2743 Yes Premium Aloy Rail No Bulk Customer No
Sub-Array Sub-Array 122" Rail 162"Rail Rail Mid End Edge Roof
Modules Splices Clamps Clamps Screen Attachments
1 16 6 4 8 28 8 0 32
2
TOTALS 16 6 4 8 28 8 0 32
Page 1 of 3
Frazer Solar Racking
SnapNrack Series 100 Calculator
Proposed Bill of Materials
Part Number Description Qty
015-09822 SNAPNRACK,STANDARD RAIL SET,1221N,BLACK,6 PC 1
015-09818 SNAPNRACK,STANDARD RAIL SET,1621N,BLACK,2 PC 2
242-04015 SNAPNRACK,BONDING STANDARD RAIL SPLICE ASSEMBLY,BLACK 8
242-02055 SNAPNRACK,BONDING MID CLAMP ASSEMBLY,1.50-2.00IN,BLACK 28
242-02063 SNAPNRACK,BONDING UNIVERSAL END CLAMP ASSEMBLY 8
232-01023 SNAPNRACK RAIL END CAP,STANDARD,BLACK 8
242-02700 SNAPNRACK,BONDING L-FOOT KIT W/BASE AND FLASHING,CLEAR L-FOOT 32
242-02101 SNAPNRACK,GROUNDING LUG ASSEMBLY 2
Total Weight: 125.74 lbs
System Total Weight: 830.00 lbs
Array Area=16 modules x(41.2"x 61.4"/144 sq.inch per sf)=281 sf
Pounds per Square Foot of Array=830 lbs/281 sf=2:95 psf item 5 checklist
Pounds per attachment=830 lbs/32=26 Ibs per attachment Item 6 checklist
Page 2 of 3
Modules Per 8 Array Pitch(degrees) 12 Sub-Array Modules 16
Row
Module 2 Building Height(ft) 12 Edge Screen(ft) 0
Row
Orientation Portrait Attachment Spacing 72 Attachment Spacing 48 Array Power(kW) 5,232
inches Override inches
The maximum recommended rail span for this sub-array is 72 inches.The rail span for modules located in edge zones is reduced by 24 inches to 48 inches
Group 1 Rail Group 2 Rail Group 3 Rail Group 4 Rail Group S Rail 122'Rail 162"Rail Row Mid Row End Row Attach- Module Rail
len th Len th Lenath Len h Length Qtv QtvClams Clams Splices ments Bonding Bonding
332.44 3 2 14 4 4 16 0 1 � QaQ
332.44 3 2 14 4 4 16 0 1 � ��❑ a
Sub-Array 6 4 28 8 8 32 0 2
Totals
Page 3 of 3
• 4���'t-s
rv�� PV install Checklist Solar Agent: Jeff Randall Client Name: Raymond Jon Frazer
Power Trip Energy Corp
83 Denny Ave
Port Townsend,WA 98368
(360) 643-3080
www.powertripenergy.com
Lie#POWERTE964JN
Project: Frazer Residence
Date: May 29,2015
Client: (Raymond)Jon Frazer
Phones: 360-460-5499&(360)460-1071
Address: 139 West 2nd Street, Port Angeles,WA 98362
System Description: 5.23KW Grid tied PV
Line Drawing:
Solar Modules
5.23 kW PV Array System DC Disconnect
Mounted on South house roof. Built into inverter
- 16 SunPower 327 watt
monocrystalline modules(SPR-
820-327)
Inverter
SunPower 6 kW synchronous inverter. Location
west interior house wall(attached garage).
SPR-6000p-TL
Max output: 6,000 watts
Operating voltage: 240 VAC
AC System Disconnect—Visibly
Open&Lockable(Line)
City of Port Angeles Located on west exterior house wall
Grid adjacent to city of Port Angeles
revenue meter.
City of PA Net Meter
Located on west exterior house
wall
Meter#: 14012
Production Meter Line I Line 2
Main Service Panel Located on west exterior
(Load) house wall adjacent to city
200 Amps located on
of Port Angeles revenue Load t Lia 2
west interior wall of meter.
house wall(in attached
garage).