PREPARED 9/12/16, 9:22:55 INSPECTION TICKET PAGE 5
CITY OF PORT ANGELES INSPECTOR: JAMES LIERLY DATE 9/12/16
------------------------------------------------------------------------------------------------
ADDRESS . : 1401 PENDLEY CT SUBDIV:
CONTRACTOR THURMAN SUPPLY PHONE (360) 457-8591
OWNER ROBERT C BRIGGS PHONE
PARCEL 06-30-01-8-6-0140-0000-
APPL NUMBER: 16-00001314 RES MECHANICAL PERMIT
---------------------------------------------—---------------------------------------------
PERMIT: ME 00 MECHANICAL PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
--------- --——----------—---—-—-------------——----------- ----------
ME99 01 9/12/16 MECHANICAL FINAL -
��✓(–�(\/— September 12, 2016 8:19:14 AM jlierly.
907-750-8652 Robert /Wood stove
-------------------------------------- COMMENTS AND NOTES --------------------------------------
CITY OF PORT ANGELES
i�►+�� DEPARTMENT OF COMMUNITY & ECONOMIC DEVELOPMENT- BUILDING DIVISION
321 EAST 5TH STREET, PORT ANGELES, WA 98362
Application Number . . . . . 16-00001314 Date 8/31/16
Application pin number . . . 312428
Property Address . . . . . . 1401 PENDLEY CT REPORT SALES TAX
ASSESSOR PARCEL NUMBER: 06-30-01-8-6-0140-0000-
Application type description RES MECHANICAL PERMIT on your state excise tax form
Subdivision Name . . . . . . to the Cit of Port Angeles
Property Use Y 9
Property Zoning . . . . . . . RS9 RESDNTL SINGLE FAMILY (Location Code 0502)
Application valuation . . . . 1800
----------------------------------------------------------------------------
Application desc
install customer supplied free standing wood stove
----------------------------------------------------------------------------
Owner Contractor
ROBERT C BRIGGS THURMAN SUPPLY
1401 PENDLEY CT 1807 E. FRONT ST.
PORT ANGELES WA 98363 PORT,ANGELES WA 98362
(360) 457-8591
Permit . . . . . . MECHANICAL PERMIT
Additional desc FREESTANDING WOOD STOVE
Permit Fee . . . . 60.65 Plan Check Fee . . .00
Issue Date . . . . 8/31/16 Valuation . . . . 0
Expiration Date 2/27/17
Qty Unit Charge Per Extension
BASE FEE 50.00
- -1.00-------10.6500 EA ME-STOVE/FIREPLACE/MISC. APP. 10.65
--------------------------
Special Notes and Comments
Per Washington State Code 51-51-315,
installation of Carbon Monoxide
detector(s) is required if you are
installing or replacing a fuel burning
appliance (wood, pellet, gas)and must be
in place prior to the final inspection
of this permit. They are required to be
place directly outside of each sleeping
area and at least one on each floor of
the house:
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 60.65 60.65 .00 .00
Plan Check Total .00 .00 .00 .00
Grand Total 60.65 60.65 .00 .00
�vl
Separate Permits are required forelectrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes
null and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned
for a period of 180 days after the work has commenced, or if required inspections have not been requested within 180 days from the
last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions
of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does
not presume to give authority to violate or cancel the provisions 9 Y p s of any state or local law regulating construction or the performance of
construction.
08 31 2d16 -��—Obertc,
Date Print Name Signature of Contractor or Authorized Agent Signature of Owner(i owner is builder)
T:Forms/Building Division/Building Permit
BUILDING PERMIT INSPECTION RECORD
-- PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS-
Building Inspections 417-4815 Electrical Inspections 417-4735
Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886
IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED.
POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE.
Inspection Type Date Accepted By Comments
FOUNDATION:
Footings
Stemwal I
Foundation Drainage/Downspouts
Piers
Post Holes(Pole Bldgs.)
PLUMBING:
Under Floor/Slab
Rough-fn
Water Line Meter to Bldg)
Gas Line
Back Flow/Water
AIR SEAL:
Walls
Ceiling
a
FRAMING:
Joists/Girders/Under Floor
a Shear Wall/Hold Downs
Walls/Roof/Ceiling
Drywall Interior Braced Panel Only)
T-Bar
INSULATION:
Slab
Wall/Floor/Ceiling
MECHANICAL:
Heat Pum /Furnace/FAU/Ducts
Rough-In
Gas Line
Wood Stove/Pellet/Chimney
Commercial Hood/Ducts
MANUFACTURED HOMES:
Footing/Slab
IBlocking&Hold Downs
Skirting
PLANNING DEPT. Separate Permit#s SEPA:
Parkin /Lighting ESA:
Landscaping SHORELINE:
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE
Inspection Type Date Accepted By
Electrical 417-4735
Construction - R.W. PW I Engineering 417-4831
Fire 417-4653
Planning 417-4750
Building 417-4815
THE For City Use
CITY OF
Permit# 3f 7
W A S H I N G T O N , U. S. Date Received:
321 E 51h Street Date Approved -.3/-/Jo
Port Angeles,WA 9836
P:360-417-4817 F:360-417-4711
Email:permits@cityofpa.us BUILDING PERMIT APPLICATION
Project Address: &J-r�
/ Phone: q07 750-
Primary
Prima Contact: e,, R01995 Email: P,
NameI i �'�� Phone V 50 w
6 57-2
Property Mailing Ad sEmail
Owner C �O� 1l� C�' xJ4rCe MA04com
jJ h' �
City xt E I� State j„ l�S//I d/G I U'4/ Zip 78363
Name V�� E�2C ffl ` 1 Phone�V
Contractor Address ( F Email
Information city State zip
Contractor License# Exp.Date:
Legal Description: Zoning: Tax Parcel# Project Value: (materials and labor)
$ 1.
Residential $I Commercial ❑ Industrial ❑ Public ❑
Permit Demolition ❑ Fire ❑ Repair ❑ Reroof(tear off/lay over) ❑
Classification For the following,fill out both pages of permit application:
(check New Construction ❑ Exterior Remodel ❑ Addition ❑ Tenant Improvement ❑
appropriate) Mechanical IS Plumbing ❑ Other ❑
-j Fire Sprinkler System Proposed Irrigation System Proposed or Proposed Bathrooms Proposed Bedrooms
or Existing? Yes 8 No ❑ Existing? Yes ❑ No M
In addition to standard hard copy submittals please send a PDF copy of all Stormwater plans and Engineering to
www.stormwater ci o a.us
Project Description (, oo
Is project in a Flood Zone: Yes ❑ No13 Flood Zone Type:
If in a Flood Zone, what is the value of the structure before proposed improvement? $
I have read and completed the application and know it to be true and correct.I am authorized to apply for
this permit and understand that it is my responsibility to determine what permits are required and to
obtain permits prior to work. I understand that plan review fees are not refundable after review has
occurred. I understand that I will forfeit review fees if I withdraw the application before the permit is
issued. I understand that if the permit is not picked up/issued within i8o days of submittal,the application
will be considered abandoned and the fees will be forfeited.
1-311 2D V
VV 40C
Date Print Name Signature
Residential Structures
Existing Proposed Construction For Office Use
Area Descriptions(SQ FT) Floor area Floor area $Value new area
Basement
First Floor
Second Floor
Covered Deck/Porch/Entry
Deck(over 30"or 2" floor)
Garage
Carport
Other(describe)
Area Totals
Commercial Structures
Area Descriptions(SQ FT) Existing Proposed Construction For Office Use
Floor area Floor area $Value new area
Existing Structure(s)
Proposed Addition
Tenant Improvement?
Other work(describe)
Site Area Totals "
Lot/Site Coverage Calculations
Lot Size (sq ft) Lot Coverage(sq ft)foot print of %Lot Coverage(Total lot cov_lot size) Max Bldg Height
all structures sq ft
Site Coverage(Sq Ft of all impervious) %of Site Coverage(total site cov_lot size)
Mechanical Fixtures
Indicate how many of each type of fixture to be installed or relocated as part of this project.
Air Handler Size: # Haz/Non-Haz Piping Outlets:
Appliance Exhaust Fan # Heater(Suspended,Floor,Recessed wall) #
Boiler/Compressor Size: # Heating/Cooling appliance #
repair/alteration
Evaporative Cooler(attached,not # Pellet Stove/Wood-burning/Gas #
portable) Fireplace/Gas Stove/Gas Cook Stove/Misc.
Fuel Gas Piping #of Outlets: Ventilation Fan,single duct #
Furnace/Heat Pump/ Size: # Ventilation System #
Forced Air Unit
Plumbing Fixtures
Indicate how many of each type of fixture to be installed or relocated
Plumbing Traps # Water Heater #
Plumbing Vent piping # Medical gas piping #of Outlets:
Water Line # Fuel gas piping #of Outlets:
Sewer Line # Industrial waste pretreatment
interceptor Grease Trap) Size
Other(describe):
T:\Forms\2015 CED Form Updates\Building&Permitting\BP\Building Permit 20150415.docx
Address:
1401 Pendley Court
PREPARED 5/25/16, 8:20:49 INSPECTION TICKET -• PAGE 1
CITY OF PORT ANGELES INSPECTOR: JAMES LIERLY DATE 5/25/16
ADDRESS . : 1401 PENDLEY CT SUBDIV:
CONTRACTOR : PHONE
OWNER ROBERT C BRIGGS PHONE
PARCEL 06-30-01-8-6-0140-0000-
APPL NUMBER: 15-00000409 RES NEW SFR
---------------------- ---
PERMIT: BPR 00 BUILDING PERMIT - RESIDENTIAL
REQUESTED INSP ' DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
--------------------------------------------------' ------—------—---—---------
BL1 01 8/26/15 JLL BLDG FOUNDATION FOOTING
8/26/15 AP August 26, 2015 9:19:10 AM jlierly.
August 26, 2015 5:08:05 PM jlierly.
BL2 01 9/01/15 JLL BLDG FOUNDATION STEM WALL
9/01/15 AP September 1, 2015 10:17:16 AM jlierly.
Bruce
September 1, 2015 4:08:45 PM jlierly.
DSD O1 9/16/15 JLL BLDG DOWN SPOUT DRAINS
9/16/15 AP September 16, 2015 10:09:59 AM jlierly.
September 16, 2015 5:00:08 PM jlierly.
BFF O1 10/08/15 JLL BLDG FLOOR FRAMING
10/08/15 AP October 8, 2015 9:19:39 AM jlierly.
Bruce 912-0079
October 8, 2015 3:43:13 PM jlierly.
BEXS 01 12/10/15 JLL BLDG EXTERIOR SHEETING
12/10/15 AP December 10, 2015 9:13:57 AM jlierly.
bruce 912-0079
December 10, 2015 4:07:38 PM jlierly.
BAIR 01 2/04/16 JLL BLDG AIR SEAL
2/04/16 AP February 4, 2016 8:32:29 AM jlierly.
February 4, 2016 4:12:30 PM 'jlierly.
BL3 01 2/04/16 JLL BLDG FRAMING
2/04/16 AP February 4, 2016 8:32:46 AM jlierly.
Bruce
February 4, 2016 4:12:30 PM jlierly.
BLI O1 2/12/16 JLL BLDG INSULATION
2/12/16 AP February 12, 2016 9:13:05 AM jlierly.
Bruce
February 12, 2016 4:53:24 PM jlierly.
FD99 01 5/16/16 MCS FIRE DEPARTMENT FINAL
5/16/16 AP May 16, 2016 2:45:37 PM msanders.
May 16, 2016 2:46:17 PM msanders.
BL99 01 5/25/16 BLDG FINAL
0 May 24, 2016 12:03:50 PM jlierly.
Bruce 912-0079
--- -----------------------------------------
PERMIT: ME 00 MECHANICAL PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------- - - ---------
ME99 01 5/25/16 MECHANICAL FINAL
May 24, 2016 12:04:30 PM jlierly.
---------------------------------------------- ---------
PERMIT: PL 00 PLUMBING P RMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
----------------------------------- CONTINUED ONTO NEXT PAGE
-----------------------------------
CITY OF PORT ANGELES
DEPARTMENT OF COMMUNITY& ECONOMIC DEVELOPMENT- BUILDING DIVISION
321 EAST 5TH STREET, PORT ANGELES, WA 98362
�0
Application Number . . . . . 15-00000409 Date 5/08/15
Application pin number . . . 297987
Property Address . . . . . . 1401 PENDLEY CT 111
ASSESSOR PARCEL NUMBER: 06-30-01-8-6-0140-0000- REPORT SALES TAX
Application type description RES NEW SFR on your state excise tax form
Subdivision Name . . . . . .
Property Use . . . . . . . . to the City of Port Angeles
Property Zoning . . . . . . . RS9 RESDNTL SINGLE FAMILY (Location Code 0502)
Application valuation . . . . . 114302
Application desc
1196SF 1 STRY SFR W/116SF COV PRCH, 375 GARAGE
----------------------------------------------------------------------------
Owner Contractor
ROBERT C BRIGGS OWNER
1401 PENDLEY CT
PORT ANGELES WA 98363
--- Structure Information 000 000 1687SQ FT SINGLE STORY SFR ---
Other struct info . . . . LOT SIZE 9015.00
PROPOSED LOT COVERAGE 1687.00
TOTAL LOT COVERAGE 1687.00
Permit . . . . . . BUILDING PERMIT -RESIDENTIAL
Additional desc . . 1 STORY 1687 SF SFR 3 BED 2 BA
Permit Fee . . . . 1104.25 Plan Check Fee 717.76
Issue Date . . . . 5/08/15 Valuation . . . . 114302
Expiration Date 11/04/15
Qty Unit Charge Per Extension
BASE FEE 1020.25
15.00 5.6000 THOU BL-100,001-500K (5.60 PER K) 84.00
Permit . . . . . . MECHANICAL PERMIT
Additional desc . . MECHANICAL SFR
Permit Fee . . . . 141.60 Plan Check Fee .00
Issue Date . . . . 5/08/15 Valuation . . . . 0
Expiration Date 11/04/15
Qty Unit Charge Per Extension
BASE FEE 50.00
1.00 14.8000 EA ME-FURN/HP/FAU < OR = 5 TON 14.80
3.00 7.2500 EA ME-VENT FAN (SINGLE DUCT) 21.75
1.00 10.6500 EA ME-HOOD/DUCT-MECH. EXHAUST 10.65
3.00 14.8000 EA ME-HEATER(SUSP/WALL/FLOOR-MTD) 44.40
------------------ ----------------------------------------------------------
Permit . . . . . . PLUMBING PERMIT
Additional desc . .
Permit Fee . . . . 149.00 Plan Check Fee .00
Issue Date . . . . 5/08/15 valuation . . . . 0
Expiration Date . . 11/04/15
Qty Unit Charge Per Extension
Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes
null and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned
for a period of 180 days after the work has commenced, or if required inspections have not been requested within 180 days from the
last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions
of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does
not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
const uction.
���� s� /3P— Jc'L n-7 _Ll
Date Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder)
T:Forms/Building Division/Building Permit
s _
BUILDING PERMIT INSPECTION RECORD
-- PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS—
Building Inspections 417-4815 Electrical Inspections 417-4735
Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886
IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED.
POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE.
Inspection Type Date Accepted By Comments
FOUNDATION:
Footings
Stemwail
Foundation Drainage/Downspouts
Piers
Post Holes(Pole Bldgs.)
PLUMBING:
Under Floor/Slab
Rough-In
Water Line(Meter to Bldg)
Gas Line
Back Flow/Water FINAL Date Accepted b
AIR SEAL:
Walls
Ceiling
FRAMING:
Joists/Girders/Under Floor
Shear Wall/Hold Downs
Walls/Roof/Ceiling
Drywall Interior Braced Panel Only)_
T-Bar
INSULATION:
Slab
Wall/Floor/Ceiling
MECHANICAL:
Heat Pum /Furnace/FAU/Ducts
Rough-In
Gas Line
Wood Stove/Pellet/Chimney
Commercial Hood/Ducts FINAL Dale Accepted b
MANUFACTURED HOMES:
Footing/Slab
Blocking&Hold Downs
Skirting
PLANNING DEPT. Separate Permit#s SEPA:
Parkin /Lighting ESA:
Landscaping SHORELINE:
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE
Inspection Type Date Accepted By
Electrical 417-4735
Construction- R.W. PW /Engineering 417-4831
Fire 417-4653
Planning 417-4750
Building 417-4815
T:Forms/Building Division/Building Permit
CITY OF PORT ANGELES
r '- DEPARTMENT OF COMMUNITY& ECONOMIC DEVELOPMENT- BUILDING DIVISION
321 EAST 5TH STREET, PORT ANGELES, WA 98362
Page 2
Application Number . . . . . 15-00000409 Date 5/08/15
Application pin number . . . 297987 REPORT SALES TAX
Qty Unit Charge Per Extension on your state excise tax form
.00
6.00 7.0000 EA PLS42.00E FEE 0PLUMBING TRAP to the City of Port Angeles
1.00 7.0000 EA PL-WATER LINE 7.00 (Location Code 0502)
4.00 7.0000 EA PL-DRAIN VENT PIPING' 28.00
1.00 15.0000 EA PL-SEWER LINE 15.00
1.00 7.0000 EA PL-WATER HEATER 7.00
----------------------------------------------------------------------------
Special Notes and Comments
Address numbers shall be plainly visible from the street.
Address numbers shall be a minimum of six inches high and be
of contrasting color from the background.
All homes in new subdivisions that are outside of the Fire
Department four-minute response area shall be equipped with
residential fire sprinkler systems that comply with the
International Fire Code (IFC) and National Fire Protection
Association (NFPA) .
Electrical load calculations and electrical permits are
required.
Ditches & 12" culverts will be installed to City Stanards.
See Public Works Engineering for Standards.
1) Standard Stormwater Comments for temporary erosion
control. This is part of a larger plan of development,
greater than 1 acre.
This includes
1. Mark Clearing Limits
2. Establishing Construction Access
3. Control Flow Rates
4. Install sediment controls BMPs.
S. Stabilize exposed soils
6. Protect slopes from erosion
7. Protect drain inlets
8. Control pollutants including but not limited to spills,
concrete wash out, exposed aggregate processes, concrete
grinding and saw cut waste water. A marked contained
concrete washout area is required may not discharge truck
wash water to sewer, ditches or ground.
9. Maintain temporary and permanent erosion control BMPS
during project
10. Update TESL plans as changes take place
No downspouts shall be connected to sanitary sewer.
Also include: Consider applying for the City Green
Infrastructure Rebate of up to $750 towards the materials to
install a rain garden to control roof or driveway runoff.
Trench safety per applicable laws. Temp erosion control and
surface restoration responsibility of applicant. Contact
City inspector prior to start of work @ 360 417-4831. No
attachment to sanitary sewer of stormwater roof leaders,
foundation drains, yard drains, or any other CSO
contribution is allowed.
Sanitary sewer connection inspection is required by
Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes
null and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned
for a period of 180 days after the work has commenced, or if required inspections have not been requested within 180 days from the
last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions
of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does
not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construction.
Date Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder)
T:Forms/Building Division/Building Permit
BUILDING PERMIT INSPECTION RECORD
— PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS —
Building Inspections 417-4815 Electrical Inspections 417-4735
Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886
IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED.
POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE.
Inspection Type Date Accepted By Comments
FOUNDATION:
Footings
Stemwall
Foundation Drainage/Downspouts
Piers
Post Holes(Pole Bldgs.)
PLUMBING:
Under Floor/Slab
Rough-in
Water Line Meter to Bldg)
Gas Line
Back Flow/Water FINAL Date Accepted b
AIR SEAL:
Walls
Ceiling
FRAMING:
Joists/Girders/Under Floor
Shear Wall/Hold Downs
Walls/Roof/Ceiling
Drywall Interior Braced Panel Only)
T-Bar
INSULATION:
Slab
Wall/Floor/Ceiling
MECHANICAL:
Heat Pum /Furnace/FAU/Ducts
Rough-In
Gas Line
Wood Stove/Pellet/Chimney
Commercial Hood/Ducts FINAL Date Accepted b
MANUFACTURED HOMES:
Footing/Slab
Blocking&Hold Downs
Skirting
PLANNING DEPT. Separate Permit#s SEPA:
Parkin /Lighting ESA:
Landscaping SHORELINE:
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE
Inspection Type Date Accepted By
Electrical 417-4735
Construction- R.W. PW I Engineering 417-4831
Fire 417-4653
Planning 417-4750
Building 417-4815
T:Forms/Building Division/Building Permit
CITY OF PORT ANGELES
DEPARTMENT OF COMMUNITY & ECONOMIC DEVELOPMENT- BUILDING DIVISION
321 EAST 5TH STREET, PORT ANGELES, WA 98362
Page 3
Application Number . . . . . 15-00000409 Date 5/08/15
Application pin number 297987 REPORT SALES TAX
Special Notes and Comments on your state excise tax form
Public Works prior to back fill of ditch. 24 hour advance
notice is required. Public Works Inspection request line to the City of Port Angeles
417-4831 (Location Code 0502)
The contractor making the connection to an existing water
meter is responsible to adjust water meter depth so that
there is a minimum of 4 to 6 inches of clearance between the
bottom of the meter box lid and the top of the meter at
finish grade.
Construct driveway and Sidewalks to City Standards.
Concrete with exposed aggregate or other non-standard
finishes(including colors or dyes)are not allowed in the
City road right of way. Broom finish only. An inspection by
Public Works Engineering is required prior to pouring
concrete. Public Works inspection request line 417-4831
22 foot easement on east property line to remain clear at
all times.
Separate Right of Way Construction permit required for
driveway and culverts.
---------- ---------- --
Other Fees . . . . . . . . RES UNDERGRND SERVICE FEE 770.00
SEWER SYSTEM DELV CHARGE 2260.00
STATE SURCHARGE 4.50
PW WATER SYSTEM USE FEE 2260.00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 1394.85 1394.85 .00 .00
Plan Check Total 717.76 717.76 .00 .00
Other Fee Total 5294.50 5294.50 .00 .00
Grand Total 7407.11 7407.11 .00 .00
Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes
null and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned
for a period of 180 days after the work has commenced, or if required inspections have not been requested within 180 days from the
last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions
of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does
not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construction.
Date Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder)
T:Forms/Building Division/Building Permit
BUILDING PERMIT INSPECTION RECORD
- PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS--
Building Inspections 417-4815 Electrical Inspections 417-4735
Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886
IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED.
POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE.
Inspection Type Date Accepted By Comments
FOUNDATION:
Footings
Stemwall
Foundation Drainage/Downspouts
Piers
Post Holes(Pole Bldgs.)
PLUMBING:
Under Floor/Slab
Rough-in
Water Line Meter to Bldg)
Gas Line
Back Flow/Water FINAL Date Accepted b
AIR SEAL:
Walls
Ceiling
FRAMING:
Joists/Girders/Under Floor
Shear Wall/Hold Downs
Walls/Roof/Ceiling
Drywall Interior Braced Panel Only)__
T-Bar
INSULATION:
Slab
Wall/Floor/Ceiling
MECHANICAL:
Heat Pum /Furnace/FAU/Ducts
Rough-in
Gas Line
Wood Stove/Pellet/Chimney
Commercial Hood/Ducts FINAL Date Accepted b
MANUFACTURED HOMES:
Footing/Slab
Blocking&Hold Downs
Skirting
PLANNING DEPT. Separate Permit#s SEPA:
Parkin /Lighting ESA:
Landscaping SHORELINE:
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE
Inspection Type Date Accepted By
Electrical 417-4735
Construction- R.W. PW /Engineering 417-4831
Fire 417-4653
Planning 417-4750
Building 417-4815
T:Forms/Building Division/Building Permit
TH F x 3 For City Use
Ce r csFES
/
: � £`. Permit# /'S ' 540
W A S H 1 N o � Date Received:
321 E 51h Street Date ApprovedI SC
Port Angeles,WA 9836
P:360-417-4817 F:360-417-4711
Email:permitsOcityofpa.us BUILDING PER t.� e4t-F -?I-►o aio
PLICATION -k i6 �-
l5- 4 s O if= t(
Project Address: 1401 Pendley Court Port Angeles, WA 98363
Phone:360-912-0079
Prima Contact: PHA Construction Supervisor Email:bmcco en eninsula ha.or
Nam Robert C. Briggs Phone 907-750-852
Property Mailing address 728 W. 6th Street Emailtxbrel4@yahoo.com
Owner
city Port Angeles state WA Zip 98363
Name Owner/Builder Phone
Contractor Address Email
Information city State zip
Contractor License# Exp.Date:
Legal Description: Zoning: Tax Parcel# Project Value: (materials and labor)
Jpf y &4- e 114,302.00
esidential 8 Commercial ❑ Industrial ❑ Public ❑
Permit Demolition ❑ Fire ❑ Repair ❑ Reroof(tear off/lay over) ❑
Classification For the following,fill out both pages of permit application:
(check New Construction 8 Exterior Remodel ❑ Addition ❑ Tenant Improvement ❑
appropriate) Mechanical ❑ Plumbing ❑ Other ❑
Fire Sprinkler System Proposed Irrigation System Proposed or Proposed Bathrooms Proposed Bedrooms
or Existing? Yes ❑ No D Existing? Yes [3 No 1] 2 3
In addition to standard hard copy submittals please send a PDF copy of all Stormwater plans and Engineering to
www.stormwatergskyof
pa.us
Project Description New single residence with attach garb
New single residence with attach garage
`0,3�s 9LkM=L _-e�>
Is project in a Flood Zone: Yes ❑ No@ Flood Zone Type:
If in a Flood Zone, what is the value of the structure before proposed improvement? $
I have read and completed the application and know it to be true and correct. I am authorized to apply for
this permit and understand that it is my responsibility to determine what permits are required and to
obtain permits prior to work. I understand that plan review fees are not refundable after review has
occurred. I understand that I will forfeit review fees if I withdraw the application before the permit is
issued. I understand that if the permit is not picked up/issued within i8o days of submittal,the application
will be considered abandoned and the fees will be forfeited.
4�0[f5_ A - 6 P
Date Print Name Signature
Residential Structures
Existing Proposed Construction For Office Use
Area Descriptions(SQ FT) Floor area Floor area $Value new area
Basement
First Floor 1196 $101,660.00
Second Floor
Covered Deck/Porch/Entry 116 $1,392.00
Deck(over 30"or i" floor)
Garage 375 $11,250.00
Carport
Other(describe)
Area Totals 1687 $114,302.00
Commercial Structures
Area Descriptions(SQ FT) Existing Proposed Construction For Office Use
Floor area Floor area $Value new area
Existing Structure(s)
Proposed Addition
Tenant Improvement?
Other work(describe)
Site Area Totals
Lot/Site Coverage Calculations
Lot Size(sq ft) Lot Coverage(sq ft)foot print of %Lot Coverage(Total lot cov_lot size) Max Bldg Height
9015 all structures sq ft 18.7
Site Coverage(Sq Ft of all impervious) %of Site Coverage (total site cov-lot size)
3669 40.7
Mechanical Fixtures
Indicate how many of each type of fixture to be installed or relocated as part of this project.
Air Handler Size: # Haz/Non-Haz Piping Outlets:
Appliance Exhaust Fan # Heater(Suspended,Floor,Recessed wall) #
3
Boiler/Compressor Size: # Heating/Cooling appliance #
repair/alteration
Evaporative Cooler(attached,not # Pellet Stove/Wood-burning/Gas #
portable)' Fireplace/Gas Stove/Gas Cook Stove/Misc.
Fuel Gas Piping #of Outlets: Ventilation Fan,single duct #
3
Furnace/Heat Pump/ Size: # Ventilation System #
Forced Air Unit 112k BTU 1
Plumbing Fixtures
Indicate how many of each type of fixture to be installed or relocated
Plumbing Traps # Water Heater # I
s
Plumbing Vent piping # Medical gas piping #of Outlets:
Water Line # Fuel gas piping #of Outlets:
Sewer Line # Industrial waste pretreatment
1
interceptor Grease Trap) Size
Other(describe):
T:\BUILDING\APPLICATION FORMS\Current BP Application\Building Permit 4-17-13.docx
40 n� 17r 25
/ 52 7"
4
1
6` 6 2 33 �� 2 X 16 r. P6 17 08 27 1 f
3 /
17 3223 is 22
2. 28 2 1304 4
/ G 32
i2 31 32 32 14 1307 d
30 29 71 s 23 a
�q ^, '�� 2 3,3 25 1322 5
321 • 0
f 6 61 14, 0
z� / V` 27406 31 30� 21 p
n� 4\J �� 26 31
a� 11gr 06 20
3 6 5 127 33- 32
1 910 1 'l0
9
3 3 0
�2 41 9
5
10
14 -1 j 29 �� 8 2
N.
7 30
��a 14 Sf 31
231 Q� �.k6 ..
13
/Z S 15 13
7 a is \ 3
/:(? 14 5 2s
5 14 s11 1402.," -
' 19
1 1 .
8
7 91 1 G�
1 On
13 16-- 91 9 i
14 \\ 2/lI 0 4092 416
15 /
15
12 10 j 173 8
6Y2 142 / 4 ,
11 �w fs
2301 315 1 14 s0
to 30 \ �6f / 112 11 �. 2 9b'
1534 Sf 2',F25
30 t31 1
r 1511 9
� 11 � 20 32 12
t4 U 1•� 30 `,8
2 �f z 2 1
6 4
r l 5
30
9 14
10 3 10
` 2202 20 tt 2
'J• 12
s ^
" \ S
20 62 62 r' 13 2 1114
_ .........
Prescriptive Ener ' Code:Compliance for All Climate Zones in Washington
Project lriformationContact Information
Bob Br► s. f'enmsula Fious►n Auth r
, 99.�: v � _._. _= .,_ _. n 9�
1401Pendley Court ` v2603Francis� _ >
PortAngeles"A'98363 X Port An eles WA98362
This project will use the requirements of the Prescriptive Path below and incorporate the
the minimum values listed. In addition, based on the size of the structure,the appropriate
number of additional credits are checked as chosen by the permit applicant.
Authorized Representative Date
All Climate Zones
_.
. .. .. .......
R-Value' U-Factora
Fenestration U-Factorb n/a 0.30
Skylight U-Factor n/a 0.50
Glazed Fenestration SHGCb.e n/a n/a
Ceiling 44 0.026
Wood Frame Wall9,k,l 21 int 0.056
Mass Wall R-Value' 21/21' 0.056
Floor 309 0.029
Below Grade Wall°.k 10/15/21 int+TB 0.042
Slabs R-Value& Depth 10, 2 ft n/a
*Table R402.1.1 and Table R402.1.3 Footnotes included on Page 2.
Each dwelling unit in one and two-family dwellings and townhouses,as defined in Section 101.2 of the
International Residential Code shall comply with sufficient options from Table R406.2 so as to achieve the
following minimum number of credits:
01.Small Dwelling Unit: 0.5 points
Dwelling units less than 1500 square feet in conditioned floor area with less than 300 square feet of fenestration
area. Additions to existing building that are less than 750 square feet of heated floor area.
❑2. Medium Dwelling Unit: 1.5 points
All dwelling units that are not included in#1 or#3, including additions over 750 square feet.
❑3. Large Dwelling Unit: 2.5 points
Dwelling units exceeding 5000 square feet of conditioned floor area.
❑4. Dwelling unit other than one and two-family dwellings and townhouses: Exempt
As defined in Section 101.2 of the International Residential Code
Table R406.2 Summary
Option Description Credit(s)
1a Efficient Building Envelope 1a 0.5 ❑
1b Efficient Building Envelope 1b 1.0 ❑
1c Efficient Building Envelope 1c 2.0 ❑
2a Air Leakage Control and Efficient Ventilation 2a 0.5 ❑
2b Air Leakage Control and Efficient Ventilation 2b 1.0 ❑
2c Air Leakage Control and Efficient Ventilation 2c 1.5 ❑
3a High Efficiency HVAC 3a 0.5 ❑
3b High Efficiency HVAC 3b 1.0 ❑
3c High Efficiency HVAC 3c 2.0 ❑
3d High Efficiency HVAC 3d 1.0 F 1.0
4 High Efficiency HVAC Distribution System 1.0 ❑
5a Efficient Water Heating 0.5 ❑
5b Efficient Water Heating 1.5 ❑
6 Renewable Electric Energy 0.5 *1200 kwh 0.0
Total Credits - 1.00
*Please refer to Table R406.2 for complete option descriptions
http://www.energy.wsu.edu/Documents/Table 406:2 Energy Credits 2012. WSEC.pdf
10
C
?AA's y�l
rz
'\ rTGjnRAIiJ
Ndl Mi
dJ p \ PI 4A ijF5 -
�tu J
I
s
ig-
-761
N � SCJ
r=200
1+01 POMEt r-*eWP No2T�1
POIZT AM;P— -S.VA* 9$363
COUNTY OF CLALLA
PLNPLE.Y COU LOT lit
LOT COV r- 1687/90156F = 18.7%
SITE COVQZA�L 3669/90155F = 4079
HOUSE STYL11E.'NEIL-U
� ' � .3a ,
• f I I i I 1 � i I � ' }-r-i.-�._. � i (t.� i r 4_._-�-_� i ' ' i j I �-
JAIf LII
r
Af--
-.F
•—; t s$1 i _1 4L � /0
i f i I I i I
- --� -I —32777-�
( r I
-�--
If
7'
--- - -, -- --�- -- - ` +fir•-rQ-t.ff.:-!__
-• - —�--. ---i� - - --�- -� - i-r-=;- ---j-- i-tet Cy3SY�..�':-s-!�-*.--^-I-,� --%- -Y--� F _,-_ -.
, t 1 �i A
r
---�— - I- ---� kd.t f �J --, €�3'•:c���� 3!-"p'�.t� � s°7`cv7•`�}�r��'� i----1--- ,— ---- 7-_ —r----- ---
r
7
-�� 11 �------+-
4
---�-,-iii-'-t i �'�-�--'f--�--i--I =--i-i j I ; ! � �--�--_.•_ - - ! -�---;-+-
-
'
--Ij---t--
- : - - - -
-
- -( Coe -- -- -i-F-
VV
i
Z1� Lel.
_ ) *
I j Y I -- -:
!
IVA
UrV/ (3 W
/11 to
_ 1414
17 , ' I ��---- - - -
- t
V
� r
+
I _
j L
`! =Y/,`'� f
I i
--
-- r-- --- -z ; - - -I--
—1—'——! 1--.•—�_ i '—}� ?_. 1 � J ( , i I � �� I i 1 t � I_ � I ! �� + s � 1 I ..—.
1
JG
Ml
l7v I
VL
t;J
,,-{-�----rte - - '- �- f /�� S -{
r j
r
T4
Ell
TY
1 - -
:
11 4
I
r—i � ,--,--i— t'` '���r—�--��I 1_��_.—Y_� _llt,i,� (—�� f L��_I_I_ + ��— � .—� _�•. i i� ---- ,
i
I !
"
,
i i +
r ,
r-
I !
i s
ILI
If
if
`���� �"�-�1 T-i , �__�___-- � t 4 ' ! l- �- - � I -}---•moi-� +
! ! ---i---- +
7-1
k 9-
W IC�C�C�+x_17,
-
i
i
•
1
I
1=-I"�`--•�"-'"---T---�.-�---r-.��j-/��-�� I !-� L��LS-_' �{.��+ 1 C% l�l�-�-F�-�_4--•-_
• { { I { { L+ � ' I I I Y ' I I I I 1 i 1' I � { � ' I '/ ' 1
JT
�_4" L
77
-77
_77 7t 77-L 7�71 Z_i-/-- "
55
, I
� i I
y e
_
' { —r—; ice_—i `' � f j � I � i —� � { i 1 � I I L_ •-
T •
rr'
t
2
Aby?�-1 - - - - - -
- .
t
YS3.
Y7,17 T
--
'
7 71
6'T 'ti(\ VY• lSl?-
�akA t' 5'
-I� 1 V 1..__ '���� ��1 � 1 ' 1 1 I i 1 1 I ' I ' i � , f ; •--
01Y_
3Y�3__ 1 �pio
-
X
RX 66 4
MECAWind Version 2 . 1 . 0 . 5 per ASCE 7-05
Developed by MECA Enterprises, Inc. Copyright 2012 www.mecaenterprises.ccm
Date 10/11/2012 Project No. 12176
Company Name ZENOVIC & ASSOCIATES, INC. Designed By SRH
Address 301 EAST 6TH STREET, SUITE 1 Description 28x40 SFR
City PORT ANGELES Customer Name PENINSULA HOUSING AUTHORITY
State WA Proj Location CLALLAM COUNTY, WA
File Location: X:\12176 HOUSING AUTHORITY\ENGR\Structual\28x40 SFR.wnd
Detailed Wind Load Design (Method 2) per ASCE 7-05
Basic Wind Speed(V) = 100.00 mph Structure Type = Building
Structural Category = II Exposure Category = C
Natural Frequency = N/A Flexible Structure = No
Importance Factor = 1.00 Kd Directional Factor = 0.85
Alpha = 9.50 Zg = 900.00 ft
At = 0.11 Bt = 1.00
Am = 0.15 Bm = 0.65
Cc = 0.20 1 = 500.00 ft
Epsilon = 0.20 Zmin = 15.00 ft
Slope of Roof = 4 : 12 Slope of Roof(Theta) = 18.45 Deg
Ht: Mean Roof Ht = 10.34 ft Type of Roof = Gabled
RHt: Ridge Ht = 12. 67 ft Eht: Eave Height = 8.00 ft
OH: Roof Overhang at Eave= .00 ft Roof Area = 1181.00 ft^
2
Bldg Length Along Ridge = 40.00 ft Bldg Width Across Ridge= 28 .00 ft
Gust Factor Category I Rigid Structures - Simplified Method
Gustl: For Rigid Structures (Nat. Freq.>1 Hz) use 0.85 = 0.85
Gust Factor Category II Rigid Structures - Complete Analysis
Zm: 0. 6*Ht = 15.00 ft
lzm: Cc* (33/Zm) ^0.167 = 0.23
Lzm: 1* (Zm/33) ^Epsilon = 427.06 ft
Q: (1/ (1+0. 63* ( (B+Ht) /Lzm) ^0.63) ) ^0.5 = 0. 94
Gust2: 0.925* ( (1+1.7*lzm*3.4*Q) / (1+1.7*3.4*lzm) ) = 0.89
Gust Factor Summary
Not a Flexible Structure use the Lessor of Gustl or Gust2 = 0.85
Figure 6-5 Internal Pressure Coefficients for Buildings, GCpi
GCPi : Internal Pressure Coefficient = +/-0.18
Figure 6-6 External Pressure Coefficients
Cp - Loads on Main Wind-Force Resisting Systems(Method 2)
heta
h
L
z
B -
Kh: 2.01* (Ht/Zg) ^ (2/Alpha) = 0.85
Kht: Topographic Factor (Figure 6-4) = 1.00
Qh: .00256* (V) ^2*I*Kh*Kht*Kd = 18.47 psf
Cpww: Windward Wall Cp(Ref Fig 6-6) = 0.80
Roof Area = 1181.00 ft^2
Reduction Factor based on Roof Area = 0.80
MWFRS-Wall Pressures for Wind Normal to 40 ft wall (Normal to Ridge)
Wall Cp Pressure Pressure
+Gcpi (psf) -Gcpi (psf)
--------------- ------ ----------- -----------
Leeward Wall -0.50 -11.18 -4.53
Side Walls -0.70 -14.32 -7.67
Wall Elev Kz Kzt qz Press Press Total Shear Moment
ft psf +GCpi -GCPi +/-Gcpi Kip K-ft
--------------------------------------------------------------------------------
Windward 12.67 0.85 1.00 18.47 9.24 15.89 20.41 10.34 65.53
Note: 1) Total = Leeward GCPi + Windward GCPi
2) Shear and Moment are sum of forces (Leeward+Windard) acting on bldg walls.
Note that the shear & moment don't consider loads on roof or end gable.
Roof Location Cp +Gcpi(psf) -GCpi(psf)
----------------------- ------- ---------- ----------
Windward - Min Cp -0.42 -9.92 -3.27
Windward - Max Cp 0.05 -2.54 4.11`
Leeward Perp to Ridge -0.57 -12.27 -5.62
Overhang Top (Windward) -0.42 -6.59 -6.59
Overhang Top (Leeward) -0.57 -8.95 -8.95
Overhang (Windward only) 0.80 12.56 12.56
MWFRS-Wall Pressures for Wind Normal to 28 ft wall (Along Ridge)
Wall Cp Pressure Pressure
+GCpi (psf) -Gcpi (psf)
MecaWind Pro v2 . 2 . 4 . 5 per ASCE 7-10
Developed by MECA Enterprises, Inc. Copyright wwa.mecaenterorises.com
Date 9/18/2014 Project No. JobNo
Company Name True Designed By Engineer
Address Address Description Description
City City Customer Name : Customer
State State Proj Location Location
File Location: C:\Users\TRACY\AppData\Roaming\MecaWind\Defauit.crnd
Directional Procedure Simplified Diaphragm Building (Ch 27 Part 2)
Basic Wind Speed(V) = 130.00 mph
Structural Category = III Exposure Category = C
Natural Frequency = N/A Flexible Structure = No
Importance Factor = 1.00 Kd Directional Factor = 0.85
Alpha = 9.50 Zg = 900.00 ft
At = 0.11 Bt = 1.00
Am = 0.15 Bm = 0.65
Cc = 0.20 1 = 500.00 ft
Epsilon = 0.20 Zmin = 15.00 ft
Slope of Roof = 4 : 12 Slope of Roof(Theta) = 18.43 Deg
Ht: Mean Roof Ht = 10.33 ft Type of Roof = GABLED
RHt: Ridge Ht = 12.67 ft Eht: Eave Height = 8.00 ft
OH: Roof Overhang at Eave= .00 ft Overhead Type = No Overhang
Bldg Length Along Ridge = 40.00 ft Bldg Width Across Ridge= 28.00 ft
Gust Factor Calculations
Gust Factor Category I Rigid Structures - Simplified Method
Gustl: For Rigid Structures (Nat. Freq.>1 Hz) use 0.85 = 0.85
Gust Factor Category II Rigid Structures - Complete Analysis
Zm: 0.6*Ht = 15.00 ft
lzm: Cc*(33/Zm)^0.167 = 0.23
Lzm: 1*(Zm/33)^Epsilon = 427.06 ft
Q: (1/(1+0.63*((B+Ht)/Lzm)^0.63))^0.5 = 0.94
Gust2: 0.925*((1+1.7*lzm*3.4*Q)/(1+1.7*3.4*lzm)) = 0.89
Gust Factor Summary
Not a Flexible Structure use the Lessor of Gustl or Gust2 = 0.85
Table 26.11-1 Internal Pressure Coefficients for Buildings, GCpi
GCPi Internal Pressure Coefficient = +/-0.18
Topographic Adjustment
0.33*z = 1.00
Kzt (0.33*z) : Topographic factor at elevation 0.33*z = 1.00
Vtopo: Adjust V per Para 27.5.2: V * [Kzt(0.33*z)]^0.5 = 130.00 mph
MWFRS Diaphragm Building Wind Pressures per Ch 27 Pt 2
All pressures shown are based upon ASD Design, with a Load Factor of .6
MWFRS Pressures for TWind Normal to 40 ft wall (Normal to Ridge)
WALL PRESSURES PER TABLE 27.6-1
L/B: Bldg Dim in wind Dir / Bldg Dim Normal to Wind Dir = 0.70
h: Height to top of Windward Wall = 8.00 ft
ph: Net Pressure at top of wall (windward + leeward) = 21.18 psf
p0: Net Pressure at bottom of wall (windward + leeward) = 21.18 psf
ps: Side wall pressure acting away from wall = .54 * ph = -11.44 psf
pl: Leeward wall pressure acting away from wall = .38 * ph = -8.05 psf
pwh: Windward wall press @ top acting toward wall = ph-pl = 13.13 psf
pw0: Windward wall press @ bot acting toward wall = p0-pl = 13.13 psf
ROOF PRESSURES PER TABLE 27.6-2
h: Mean Roof Height = 10.334 ft
Lambda: Exposure Adjustment Factor = 1.000
Slope: Roof Slope = 18.43 Deg
Zone Load Casel Load Case2
psf psf
1 -15.99 5.54
2 -12.90 -5.70
3 -19.86 .00
4 -17.70 .00
5 -14.52 .00
Note: A value of '0' indicates that the zone/load case is not applicable.
Notes - Normal to Ridge
Note (1) X= Along Building ridge, Y = Normal to Building Ridge, Z = Vertical
Note (2) MIN = Minimum pressures on Walls = 9.6 psf and Roof = 4.8 psf
Note (3) Area* = Area of the surface projected onto a vertical plane normal to wind.
MWFRS Pressures for Wind Normal to 28 ft wall (Along Ridge)
WALL PRESSURES PER TABLE 27.6-1
L/B: Bldg Dim in Wind Dir / Bldg Dim Normal to Wind Dir = 1.43
h: Height to top of Windward Wall = 12.67 ft
ph: Net Pressure at top of wall (windward + leeward) = 19.97 psf
p0: Net Pressure at bottom of wall (windward + leeward) = 19.97 psf
ps: Side wall pressure acting away from wall = .58 * ph = -11.64 psf
p1: Leeward wall pressure acting away from wall = .33 * ph = -6.65 psf
pwh: Windward wall press @ top acting toward wail = ph-pl = 13.32 psf
pw0: Windward wall press @ bot acting toward wall = p0-pl = 13.32 psf
ROOF PRESSURES PER TABLE 27.6-2
h: Mean Roof Height = 10.334 ft
Lambda: Exposure Adjustment Factor = 1.000
Slope: Roof Slope = 18.43 Deg
Zone Load Casel Load Case2
psf psf
---- ---------- ----------
1 -15.99 5.54 t
2 -12.90 -5.70
3 -19.86 .00
4 -17.70 .00
5 -14.52 .00
Note: A value of 10' indicates that the zone/load case is not applicable.
Notes - Along Ridge
Note (1) X= Along Building ridge, Y = Normal to Building Ridge, Z = vertical
Note (2) MIN = Minimum pressures on Walls = 9.6 psf and Roof = 4.8 psf
Note (3) Area* = Area of the surface projected onto a vertical plane normal to wind.
Total Base Reaction Summary
Description FX FY Fz Mx My MZ
Kip Kip Kip K-ft K-ft K-£t
--------------------------------------------------------------------------------------
Normal to Ridge Walls+Roof +GCpi .0 6.2 16.2 33.3 .0 .0
Normal to Ridge Walls Only +GCpi .0 6.8 .0 27.1 .0 .0
Normal to Ridge Walls+Roof -GCpi .0 8.9 0.1 4.7 .0 .0
Normal to Ridge Walls Only -GCpi .0 6.8 .0 27.1 .0 .0
Normal to Ridge Walls+Roof MIN .0 .0 .0 .0 .0 .0
Along Ridge Walls+Roof +GCpi 5.8 .0 17.5 .0 -49.5 .0
Along Ridge Walls Only +GCpi 5.8 .0 .0 .0 -30.4 .0
Along Ridge Walls+Roof -GCpi 5.8 .0 .0 .0 -30.4 .0
Along Ridge Walls Only -GCpi 5.8 .0 .0 .0 -30.4 .0
Along Ridge Walls+Roof MIN .0 .0 .0 .0 .0 .0
Notes Applying to MWFRS Reactions:
Note (1) Per Fig 27.4-1, Note 9, Use greater of Shear calculated with or without roof.
Note (2) X= Along Building ridge, Y = Normal to Building Ridge, Z = Vertical
Note (3) MIN = Minimum pressures on Walls = 9.6 psf and Roof = 4.8 psf
Note (4) MIN area is the area of the surface onto a vertical plane normal to wind.
Note (5) Total Roof Area (incl OH Top) = 1180.59 sq. ft
Note (6) LC = Load Case (Some pressures can be zero, ref ASCE 7-10 Ch 27 Pt 2)