HomeMy WebLinkAbout1401 W. 7th Street Address:
1401 W 7t" Street
/� o ) ki 7 5 -
PREPARED 9/17/13, 13:26:27 INSPECTION TICKET PAGE 1
CITY OF PORT ANGELES INSPECTOR: JAMES LIERLY DATE 9/17/13
'---------- ------------------
ADDRESS . : 1401 W 7TH ST SUBDIV:
CONTRACTOR : PHONE :
OWNER GENE H UNGER PHONE : (360) 452-2098
PARCEL 06-30-00-0-1-5292-0000-
APPL NUMBER: 13-00000095 RES DETACHED GARAGE
-------
PERMIT: BPR 00 BUILDING PERMIT - RESIDENTIAL
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
-------------------------------------------------------------------------------------------------
BL1 01 3/12/13 PB BLDG FOUNDATION FOOTING
3/12/13 AP March 11, 2013 3:49:05 PM pbarthol.
Gene 452-2098
March 12, 2013 4:34:15 PM pbarthol.
BL3 01 7/22/13 JLL BLDG FRAMING
7/22/13 AP July 22, 2013 8:28:22 AM pbarthol.
Gene 452-2098
July 22, 2013 3:57:19 PM jlierly.
BL99 01 9/17/13 BLDG FINAL
September 17, 2013 8:11:26 AM pbarthol.
Gene 452-2098
Permit in carport
-------------------------------------- COMMENTS AND NOTES --------------------------------------
BUILDING PERMIT INSPECTION RECORD
W
PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS-
Building Inspections 417-4815 Electrical Inspections 417-4735
Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886
IT IS UNLAWFUL.TO COVER,INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED.
POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE.
Inspection Type Date Accepted By Comments ea
FOUNDATION:
Footings
Stemwall
Foundation Drainage/Downspouts
Piers
Post Holes(Pole Bldgs.)
PLUMBING:
Under Floor/Slab
Rough-In
Water Line Meter to Bldg)
Gas Line
Back Flow/Water FINAL Date Accepted b
AIR SEAL:
Walls
Ceiling
FRAMING:
Joists/Girders/Under Floor
Shear Wall/Hold Downs
Walls/Roof/Ceiling
Drywall Interior Braced Panel Only)
T-Bar
INSULATION:
Slab
Wall/Floor/Ceiling
MECHANICAL:
Heat Pum /Furnace/FAU/Ducts
Rough-in
Gas Line
Wood Stove/Pellet/Chimney
Commercial Hood/Ducts FINAL Date Accepted b
MANUFACTURED HOMES:
Footing/Slab
Blocking&Hold Downs
Skirting O
PLANNING DEPT. Separate Permit#s SEPA:
Parkin /Lighting ESA:
Landscaping SHORELINE:
FINAL'INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE
a
Inspection Type Date Accepted By
Electrical 417-4735
Construction-R.W. PW I Engineering 417-4831
Fire 417-4653
Planning 417-4750
Building 417-4815
T:Forms/Building Division/Building Permit
CITY OF PORT ANGELES
i DEPARTMENT OF COMMUNITY
& ECONOMIC DEVELOPMENT-BUILDING DIVISION
321 EAST 5TH STREET, PORT ANGELES,WA 98362
Application Number . . . . . 13-00000095 Date 2/06/13
Application pin number . . . 262035
Property Address . . . . . . 1401 W 7TH ST
ASSESSOR PARCEL NUMBER: 06-30-00-0-1-5292-0000- REPORT SALES TAX
Application type description RES DETACHED GARAGE
Subdivision Name . . . . . . on your state excise tax form
Property Use . . . . . . . . to the City of Port Angeles
Property Zoning . . . . . . . RS7 RESDNTL SINGLE FAMILY (Location Code O$O2)
Application valuation . . . . 3360
---------
Application desc
CARPORT ATTACHED TO EXISTING GARAGE
----------------------------------------------------------------------------
Owner Contractor
------------------------ ------------------------
GENE H UNGER OWNER
1401 W 7TH ST
PORT ANGELES WA 983635401
(360) 452-2098
Other struct info . . . . . HARD SURFACE AREA
---------------------------------- -----------------------------------------
Permit . . . . . . BUILDING PERMIT -RESIDENTIAL
Additional desc . . CARPORT ATTACHED TO GARAGE
Permit Fee . . . . 123.75 Plan Check Fee 80.44
Issue Date . . . . 2/06/13 Valuation . . . . 3360
Expiration Date `.' 8/05/13
Qty Unit Charge Per Extension
BASE FEE 95.75
--------2.00 14.0000 THOU BL-2001-25K (14 PER K) 28.00
-------------------------------------------------------------------
-
Special Notes and Comments
January 31, 2013 10:31:28 AM sroberds.
The proposal will add an additional carport in the RS-7 for
total lot coverage of 27% and site coverage of 310. No land
use issues anticipated.
Electrical load calculations and electrical permits are
required.
The existing building sewer may be located at the same
location of the proposed construction. Any.modification or
damage to the existing building sewer will require other
permits and inspections.
----------------------------------------------------------------------------
Other Fees . . . . . . . . . STATE SURCHARGE 4.50
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 123.75 123.75 .00 .00
Plan Check Total 80.44 80.44 .00 .00
Other Fee Total 4.50 4.50 .00 .00
Grand Total 208.69 208.6.9 .00 .00
Separate Permits are required forelectrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes
null and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned
for a period of 180 days after the work has commenced, or if required inspections have not been-requested within 180 days from the
last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions
of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does
not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construction.
Date Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder)
T:Forms/Building Division/Building Permit
THE
CITY OF
1 ` EL For City Use
W A S H I N G T O N , U . S .
Permit#
321 East 51 Street Date Received:
Port Angeles, WA 98362 Date Approved 1,1,4112
P: 360-417-4817 F: 360-417-4711
permits@cityofpa.us
Building Permit Applicat on
Project Address:
Main Contact: Phone #
�,e,Pf H, tl-vicer E-Mail: (pP n+s ►� . oma►
Property NamePhone
Owner & ��''e— 1�`
Mailing Address J Email
City State Zip
- � ✓r P l�2 14/
Contractor Name Phone
Mailing Address Email
City State Zip ,
Contractor License # Expiration:
Project Value: Zoning: Tax Parcel # Lot# A/ei<1,
$ -��-4 3 D 6 3Ddp ala i�29 Z 1 `l ' ze
Type of Residential M Commercial ❑ Industrial ❑ Public ❑
Permit Demolition ❑ Fire ❑ Repair ❑ Reroof(tear off/lay over) ❑
For the following, fill out both pages of permit application:
New Construction ❑ Remodel ❑ Addition E3 Tenant Improvement ❑
Mechanical ❑ Plumbing ❑ Other ❑
Existing Fire Sprinkler System? Maximum height of structure Proposed Bedrooms Proposed Bathrooms
Yes
El
Project
Description s C�
I have read and completed the application and know it to be true and correct. I am authorized to apply for this
permit. I understand that it is my responsibility to determine what permits are required and to obtain permits
prior to working on projects. I understand that the plan review fee is not refundable after plan review has
occurred. I understand that I will forfeit the review fee if I cancel or withdraw the application before the
permit is issued. I understand that if the permit is not issued within 180 days of receipt,the application will be
considered abandoned and the fees forfeit.
Date Print Name Signature
Residential Structures
For Office Use
Area Description (SQ FT) Existing Proposed $$value
Basement
First Floor
2D��, LGB,,(
Second Floor j
Covered beck�'P&?ch'Entry
Deck
Garage
leDd (0 � G
Carport
;7zp .5�Q
Other(describe)
Area Totals ��36 3716
Commercial Structures
For Office Use
Area Descriptions (SQ FT) Existing Proposed $$Value
Existing Structure (s)
Proposed Addition
Tenant Improvement?
Other work(describe)
Area Totals
Lot/Site Coverage Calculations
Footprint(SQ FT) of all Structures: Lot Size: %Lot Coverage
SQ FT Site coverage (all impervious+ %Site Coverage
structures Q QO
Mechanical Fixtures
Indicate how many of each type of fixture to be installed or relocated as part of this project.
Air Handler Size: # Haz/Non-Haz Piping #of Outlets:
-------Heater(Suspendd Floor,Recessed wall) 4V ---
Boiler/Compressor Size: # Heating/Cooling appliance #
repair/alt ration
Evaporative Cooler(attached,not # Pellet Stove/Wood-burning/Gas #
portable) Fireplace/Gas Stove Gas Cook Stove/Misc.
Fuel Gas Piping #of Outlets: Ventilation Fan,single duct #
Furnace/Heat Pump/ Size: # Ventilation System #
Forced Air Unit
Plumbing Fixtures
Indicate how many of each type of fixture to be installed or relocated
Plumbing Traps # Fuel gas piping #of Outlets:
Water Heater # Medical gas piping #of Outlets:
Water Line # Vent piping #
Sewer Line # Industrial waste pretreatment #
interceptor
Other describe):
T:\BUILDING\APPLICATION FORMS\BUILDING PERMIT 081212.DOCX
77777777
Z,741-
.r. �� �
i
»r
� .L0. f`Y ^rM�{ $ - e• ' GGs� 5r� P 'mY� � � fi� �A`e
7,0
SI
41
4 g
�R�
40
R " ta�
;Xa
C�'r
x
reC 'P a Na, f ,$ -split`�.
r
,k"' t
on
01
lit
C
0 low
-
vow
,i$
o
1'e a .r f r s A e E�"
�
VXV
Afft
;fix
¢:,.a� g}caq,K� ��`x�'
WcF. a �. R `K
'Fl
ARPY Revisions:
13'-6.40'1--14' I 1
--i I Hedge Legal Description.
N I I I Lots 19 & 20
—10'—I--- Block 152 00
Garage I I New Townsite of Port Angeles (7)
11080 sq.ftt Car I Car0 1 Parcel No, 063000 0015292 CD M
Por. Port N
270 280 sfiLJJ L M
Pa I king LO M
I ! I o
Lawn `D Q
Lot coverage, ( ) 3
House 2086
Garage 1080
Carport 270 U Ul
Garden I Deck I New Carport 280
I 1 I ( Total = 3716 ~ +'
G)
L I Lot = 14000 Q
Percentage = 26.5
j mo�_ 'q- 0�
I I I I V L LJ
I i I House i 4-->
I I I 2086 sf I m
I I I I m , �
+
� +> _
I I Q Q
c5 n� �
I I I
Lot 20
I I ICL -C11 :1 �
I I I Q) CD o
L - - - - - - - - - - - - - - - - - - - -J (�
v
CITY OF POPT ANG CLES—Con", -T
f'13r,� T
The Issuance of this ermit f" SNE H UNG ~ U
P d upon these plans,specifi• �' OF WA Scale:
Scale:
P'
cations and other data sn, l;not P'S'.""t the building official �� tiC� 1'=2 0'
from thereafter requir'ig the corrPC":M of errors in said AT
Plans, specifications and other data, or from preventing Job;
building operations being carried on hereunder when in 12 0 0 7 S P
violation of all codes ar;i or'6,e ecs of this jurisdiction. Date
Seventh Street fetes 7
Approval Date y 14439 4; Mar 2 012
By ���F FFG/STEREO \�<v Sheet
SS/ONAL ENG
Site Pian rr
T11;7
— �� g �,�� 1
Alley Lot Line Revisions.
— Legal Description:
Lots 19 & 20
Block 152
Township of Port Angeles CO
O (Y)
Lot coverage, `D
House 2086 i M
Garage 1080 L L� CO
Patio Pavers o Hedge Carport 270 �`
r New Carport 280 �.
CD
Total = 3716 ,D Q
C-
Lot = 14000 v
U T
Percentage = 26.5_
_
1� +->
r �CD
4x12 DF-L #2 v W 0
Fence
❑HGD ❑HGD
110x70 100x70 °' M
Flower Bed m+, M
(ij CO
0) (T�
s
Garage +>
Q � Q
110 >1s 3
Car New L�
Port Car _d 7- > a)
270 sf Port n 06
280 sf - �
= 3
20 x20'x8° Footing <
o (1) +.>CB 4 w/PT4x4 post
EC 44 to beam O �:: o L
Ty )icat 4 aJ O
4x12 DF-L #2 0 a-
v c
v
----- GENE H.
P OF WA S, Scale:
V-4'
Lawn °ti Job:
L3/- 101- - 12007FP
Date:
Joan,,2013
R
-- ----. °�F FFG/STEES Sheet
SS/ONAL ENG
New S1te Pian pjg '1 2
of 4
Revisions:
m
CD
Cd
I �
Cu CC)
W �
12 � CD Q
-� C: C 3
W
Q
� n � o 0
- — ® Wlq-
A cl-
East Elevation South Elevation o)+, �,D
n) CO
0) Q,
+->
Q � Q
New O 06
d = 3 �
CD
0) O
a-
ili
U
- I �P�OF WASc�' Scale:
IE1"=8'
�2 Job:
12007EL
Date:
Jan,,2013
North Elevation F SFO�STFR, �� Sheet
NAL
3
of 4
Revisions:
Continuous Ridge Vent 00
011
Trusses @ 2' o,c, CD
"
OSB sheeting i
30# tar paper OJ OC)
30 lb. comp, roofing U-) Q"
0
12 `fl 3
l6
U Vi
H S �
Fascia with gutter W 4
downspout to infiltration �✓
under planter area C: 0J
a, 3 <
� c �
mo �
�—Cointinuous vent (DO
' Cedar rough tex W
Garage Door ECC44 brackets 4x4 posts
4x12 DF-L #2 I
H2,5 Clips to trusses E M
+'
10' min, Alley Q Q
>1 3
aJ
06
O
e — I
ravers 20"x20"x8' footing � Q
over 4 sand w/6x6 plint 3 +,
w/CB44 U
0) CD O
Section
GENE H NNG� U
OF WASyyj � Scale:
1"-4/
�! �Z Job;
12007Sec
Date:
Jan,)2013
FG/STE Sheet
c� ER ��
SS/ONAL ENG
4
of 4