HomeMy WebLinkAbout1419 Pendley Court Address:
1419 Pendley Court
PREPARED 3/03/15, 12:21:20 INSPECTIONTICKET PAGE 3
CITY OF PORT ANGELES INSPECTOR: JAMES LIERLY DATE 3/03/15
-------------------------------------------------------------------------------------------------
ADDRESS . : 1419 PENDLEY CT SUBDIV:
CONTRACTOR : PHONE
OWNER SARAH SLOTA PHONE
PARCEL 06-30-01-8-6-0120-0000-
APPL NUMBER: 14-00000743 RES NEW SFR
----------------------------------------------—------------——---------------------------
PERMIT: BPR 00 BUILDING PERMIT - RESIDENTIAL
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT * RESULTS/COMMENTS
--—-------------------------------—------—--------------------- --------------------
BL1 01 8/22/14 JLL BLDG FOUNDATION FOOTING
8/22/14 AP August 22, 2014 9:31:07 AM pbarthol.
Bruce 912-0079
August 22, 2014 11:58:33 AM jlierly.
DSD O1 9/12/14 JLL BLDG DOWN SPOUT DRAINS
9/12/14 AP September 12, 2014 12:19:34 PM pbarthol. -
Bruce 912-0079
September 12, 2014 3:56:47 PM jlierly.
BFF O1 9/19/14 JLL BLDG FLOOR FRAMING
9/19/14 AP September 19, 2014 8:37:48 AM pbarthol.
Bruce 912-0079
September 19, 2014 4:23:24 PM jlierly. -
BL9 01 10/24/14 JLL BLDG SHEARWALL
10/24/14 AP October 24, 2014 1:18:24 PM pbarthol.
Bruce 912-0079
October 24, 2014 4:02:44 PM jlierly.
BAIR O1 12/08/14 JLL BLDG AIR SEAL
12/09/14 AP December 8, 2014 9:13:34 AM pbarthol.
Bruce 912-0079
December 9, 2014 9:20:47 AM jlierly.
BL3 01 12/08/14 JLL BLDG FRAMING "
12/09/14 AP December 8, 2014 9:13:18 AM pbarthol.
Bruce 912-0079
December 9, 2014 9:20:47 AM jlierly. _
BLI O1 12/11/14 PB BLDG INSULATION
12/11/14 AP December 11, 2014 8:54:05 AM pbarthol.
December 12, 2014 9:34:14 AM pbarthol.
FFNL O1 2/06/15 KDD FIRE FINAL
2/06/15 AP February 6, 2015 12:19:57 PM kdubuc.
fire final
February 6, 2015 12:20:19 PM kdubuc.
fire final
PW99 01 2/18/15 RV PUBLIC WORKS FINAL
2/18/15 AP February 23, 2015 1:42:38 PM rvess.
February 23, 2015 1:43:01 PM rvess.
BL99 01 2/19/15 JLL BLDG FINAL
2/20/15 DA February 19, 2015 9:11:31 AM pbarthol.
February 20, 2015 4:53:05 PM pbarthol.
impact protection for heat pump unit.
Temp occupancy for 30 days issued, expires 3/19/2015
BL99 02 3/03/15 L BLDG FINAL
March 3, 2015 11:24:20 AM pbarthol.
Bollards in place
-------------------------------------- COMMENTS AND NOTES ----------
CITY OF PORT ANGELES
321 E 5TH STREET
P.O. BOX 1150
PORT ANGELES WA 98362
C E R T I F I C A T E O F O C C U P A N C Y
T E M P O R A R Y
Issue Date . . . . . . 2/19/15
Expiration Date . . . . 3/19/15
Parcel Number . . . . . 06-30-01-8-6-0120-0000-
Property Address . . . 1419 PENDLEY CT
PORT ANGELES WA 98363
Subdivision Name . . .
Legal Description . . . PENDLEY ESTATES SUB LOT 12
VOL15 PG78
Property Zoning . . . . RS9 RESDNTL SINGLE FAMILY
Owner . . . . . . . . . SARAH SLOTA
Contractor . . . . . .
O
Application number 14-00000743 000 000
Description of Work RES NEW SFR
Construction type . . .
Occupancy type
Flood Zone
Special conditions
February 19, 20 : 37 : 23 thol.
Bollards plac to pro c ump it .
Approved . . . . . . .
it i g Official
VOID UNLESS SIGNED BY BUILDING OFFICIAL
CITY OF PORT ANGELES
DEPARTMENT OF COMMUNITY&ECONOMIC DEVELOPMENT- BUILDING DIVISION
321 EAST 5TH STREET, PORT ANGELES, WA 98362
V
Application Number . . . . . 14-00000743 Date 7/16/14
Application pin number . . . 592701
Property Address . . . . . . 1419 PENDLEY CT
ASSESSOR PARCEL NUMBER: 06-30-01-8-6-0120-0000- REPORT SALES TAX
Application type description RES NEW SFR
Subdivision Name . . . . . . On your state excise tax form
Property Use . . . . . . . . to the City of Port Angeles
Property Zoning . . . . . . . RS9 RESDNTL SINGLE FAMILY (Location Code 0502)
Application valuation . . . . 114302
Application desc
1687 SQ FT SFR
----------------------------------------------------------------------------
Owner Contractor
------------------------ ------------------------
SARAH SLOTA OWNER
2202 W 16TH St E6
PORT ANGELES WA 98363 \
----------------------------------------------------------------------------
Permit . . . . BUILDING. PERMIT -RESIDENTIAL
Additional desc . . 1687 SQ FR SFR
Permit Fee . . . . 1104.25 Plan Check Fee 717.76
Q
Issue Date . . . . 7/16/14 Valuation . . . . 114302 {�
Expiration Date 1/12/15-
Qty
/12/15Qty Unit Charge Per Extension n
BASE FEE 1020.25 1�`\
15.00 5.6000 THOU BL-100,001-500K (5.60 PER K) 84.00
---------------------------------------7------------------------------------
Permit . . . . . . MECHANICAL PERMIT
Additional desc . . MECHANICAL SFR
Permit Fee . . . . 141.60 Plan Check Fee .00
Issue Date . . . . 7/16/14 Valuation . . . . 0
Expiration Date . . 1/12/15
Qty Unit Charge Per Extension
BASE FEE 50.00
1.00 14.8000 EA ME-FURN/HP/FAU < OR = 5 TON 14.80
3.00 7.2500 EA ME-VENT FAN (SINGLE DUCT) 21.75
1.00 10.6500 EA ME-HOOD/DUCT-MECH. EXHAUST 10.65
3.00 14.8000 EA ME-HEATER(SUSP/WALL/FLOOR-MTD) 44.40
----------------------------------------------------------------------------
Permit . . . . . . PLUMBING PERMIT
Additional desc . . PLUMBING SFR
Permit Fee . . . . 142.00 Plan Check Fee .00
Issue Date 7/16/14 Valuation . . . . 0
Expiration Date 1/12/15
Qty Unit Charge Per Extension
BASE FEE 50.00
6.00 7.0000 EA PL-PLUMBING TRAP 42.00
1.00 7.0000. EA PL-WATER LINE 7.00
3.00 7.0000 EA PL-DRAIN VENT PIPING 21.00
Separate Permits are required forelectrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes
null and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned
for a period of 180 days after the work has commenced, or if required inspections have not been requested within 180 days from the
last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions
of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does Q
not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construction.
G /
Date Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder)
T:Forms/Building Division/Building Permit
BUILDING PERMIT INSPECTION RECORD
PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS—
Building Inspections 417-4815 Electrical Inspections 417-4735
Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886
IT IS UNLAWFUL TO COVER,INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED.
POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE.
Inspection Type Date Accepted By Comments
FOUNDATION:
Footings
Stemwall
Foundation Drainage/Downspouts
Piers
Post Holes(Pole Bldgs.)
PLUMBING:
Under Floor/Slab
Rough-In
Water Line Meter to Bldg)
Gas Line
Back Flow/Water FINAL Date Accepted b
AIR SEAL:
Walls
Ceiling
FRAMING:
Joists/Girders/Under Floor
Shear Wall/Hold Downs
Walls/Roof/Ceiling
Drywall Interior Braced Panel Only)
T-Bar
INSULATION:
Slab
Wall/Floor/Ceiling
MECHANICAL.
Heat Pum /Furnace/FAU/Ducts
Rough-In
Gas Line
Wood Stove/Pellet/Chimney
Commercial Hood/Ducts FINAL Date Accepted b
MANUFACTURED HOMES:
Footing/Slab
Blocking&Hold Downs
Skirting
PLANNING DEPT. Separate Permit#s SEPA:
Parking/Lighting ESA:
Landscaping SHORELINE:
. r( FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE
Inspection Type Date Accepted By
Electrical 417-4735
Construction- R.W. PW I Engineering 417-4831
Fire 417-4653
Planning 417-4750
Building 417-4815
T:Forms/Building Division/Building Permit
CITY OF PORT ANGELES
'" ® DEPARTMENT OF COMMUNITY&ECONOMIC DEVELOPMENT- BUILDING DIVISION
321 EAST 5TH STREET, PORT ANGELES, WA 98362
Page 2
Application Number . . . . . 14-00000743 Date 7/16/14
Application pin number . . . 592701
REPORT SALES TAX
Qty Unit Charge Per Extension
1.00 15.0000 EA PL-SEWER LINE 15.00 on your state excise tax form
1.00 7.0000 EA PL-WATER HEATER 7.00 to the City of Port Angeles
---------------------------------------------------------------
Special Notes and Comments Location Code 0502)
June 24, 2014 11:49:31 AM pbarthol.
Plan check fees for permits 14-743 and
14-742 pain on permit 14-743. No plan
review charged on 14-742 pb
July 2, 2014 7:35:05 AM rbecker.
You did not mark on your permit, if you were installing a
fire or lawn sprinkler system. If you are installing either
one, you will need to install a backflow assembly.
If you havice any questions call Ron Becker at 360-417-4886,
fax: 360-452-4972, or E-mail: rbecker@cityofpa.us
Address numbers shall be plainly visible from the street.
Address numbers shall be a minimum of six inches high and be
of contrasting color from the background.
A full acceptance test will be required for the fire
sprinkler system.
Call for cover inspection for .all sprinkler installations.
All homes in new subdivisions that are outside of the Fire
Department four-minute response area shall be equipped with
residential fire sprinkler systems that comply with the
International Fire Code (IFC) and National Fire Protection
Association (NFPA) .
July 9, 2014 8:57:30 AM sroberds.
The permit allows for a new sfr in the RS-9 w/attached
garage for total lot cov of 19$ and site cov of 415k. No
land use issues anticipated.
Electrical load calculations and electrical permits are
required.
Ditches & 12" culverts will be installed to City Stanards.
See Public Works Engineering for Standards.
All SWPPP elements must be followed as this is part of a
larger plan of development (Pendley Ct) including:
3.1.1 Element #1 Mark Clearing Limits
3.1.2 Element 42 Establish Construction Access
3.1.3 Element #3 Control Flow Rates
3.1.4 Element #4 Install Sediment Controls
3.1.5 Element #5 Stabilize Soils
3.1.6 Element #6 Protect Slopes
3.1.7 Element #7 Protect Drain Inlets
3.1.8 Element #8 Stabilize Channels and Outlets
3.1.9 Element #9 Control Pollutants
3.1.10 Element #10 Control Dewatering
3.1.11 Element #11 Maintain BMPs
3.1.12 Element #12 Manage the Project
Consider applying for the City Green Infrastructure Rebate
of up to $750.00 towards the materials to install rain
Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes
null and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned
for a period of 180 days after the work has commenced, or if required inspections have not been requested within 180 days from the
last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions
of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does
not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construction.
Date Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder)
T:Forms/Building Division/Building Permit
BUILDING PERMIT INSPECTION RECORD
-- PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS—
Building Inspections 417-4815 Electrical Inspections 417-4735
Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886
IT IS UNLAWFUL TO COVER,INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED.
POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE.
Inspection Type Date Accepted By Comments
FOUNDATION:
Footings
Stemwall
Foundation Drainage/Downspouts
Piers
Post Holes(Pole Bldgs.)
PLUMBING:
Under Floor/Slab
Rough-In
Water Line Meter to Bldg)
Gas Line
Back Flow/Water FINAL Date Accepted b
AIR SEAL:
Walls
Ceiling
FRAMING:
Joists/Girders/Under Floor
Shear Wall/Hold Downs
Walls/Roof/Ceiling
Drywall Interior Braced Panel Only)
T-Bar
INSULATION:
Slab
Wall/Floor/Ceiling
MECHANICAL:
Heat Pum /Furnace/FAU/Ducts
Rough-In
Gas Line
Wood Stove/Pellet/Chimney
Commercial Hood/Ducts FINAL Date Accepted b
MANUFACTURED HOMES:
Footing/Slab
Blocking&Hold Downs
Skirting
PLANNING DEPT. Separate Permit#s SEPA:
Parkin /Lighting ESA:
Landscaping SHORELINE:
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE
Inspection Type Date Accepted By
Electrical 417-4735
Construction-R.W. PW I Engineering 417-4831
Fire 417-4653
Planning 417-4750
Building 417-4815
T:Forms/Building Division/Building Permit
CITY OF PORT ANGELES
. DEPARTMENT OF COMMUNITY&ECONOMIC DEVELOPMENT-BUILDING DIVISION
® 321 EAST 5TH STREET, PORT ANGELES, WA 98362
Page 3
Application Number . . 14-00000743 Date 7/16/14
Application pin number . . . 592701
---------------------------------------------------------------------------- REPORT SALES TAX
Special Notes and Comments on your state excise tax form
garden to control roof and driveway runoff. Also rebates
available for downspout disconnections.Contact Jonathan to the City of Port Angeles
Boehme at 360 11 (Location Code 0502)
All constructionon work within the City right of way requires
a separate Right of Way Construction application to be
completed by the contractor and approved by Public Works
Engineering prior to the start of work. A pedestrian or
traffic control plan is to be submitted for 'approval with
the application as necessary.
Sanitary sewer connection inspection is required by
Public Works prior to back fill of ditch. 24 hour advance
notice is required. Public Works Inspection request line
417-4831
Trench safety per applicable laws. Temp erosion control and
surface restoration responsibility of applicant. Contact
City inspector prior to start of work @ 360 417-4831. No
attachment to sanitary sewer.of stormwater roof leaders,
foundation drains, yard drains, or any other CSO
contribution is allowed.
----------------------------------------------------------------------------
Other Fees . . . . . . . . . RES UNDERGRND SERVICE FEE 770.00
SEWER SYSTEM DELV CHARGE 2260.00
STATE SURCHARGE 4.50
PW WATER SYSTEM USE FEE 2260.00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 1387.85 1387.85 .00 .00
Plan Check Total 717.76 717.76 .00 .00
Other Fee Total 5294.50 5294.50 .00 .00
Grand Total 7400.11 7400.11 .00 .00
Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes
null and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned
for a period of 180 days after the work has commenced, or if required inspections have not been requested within 180 days from the
last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions
of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does
not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construction.
Date Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder)
T:Forms/Building Division/Building Permit
BUILDING PERMIT INSPECTION RECORD
PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS
Building Inspections 417-4815 Electrical Inspections 417-4735
Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886
IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED.
POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE.
Inspection Type Date Accepted By Comments
FOUNDATION:
Footings
Stemwall
Foundation Drainage/Downspouts
Piers
Post Holes(Pole Bldgs.)
PLUMBING:
Under Floor/Slab
Rough-in
Water Line Meter to Bldg)
Gas Line
Back Flow/Water FINAL Date Accepted b
AIR SEAL:
Walls
Ceiling
FRAMING:
Joists/Girders/Under Floor
Shear Wall/Hold Downs
Walls/Roof/Ceiling
Drywall Interior Braced Panel Only)
T-Bar
INSULATION:
Slab
Wall/Floor/Ceiling
MECHANICAL.
Heat Pum /Furnace/FAU/Ducts
Rough-in
Gas Line
Wood Stove/Pellet/Chimney
Commercial Hood/Ducts FINAL Date Accepted b
MANUFACTURED HOMES:
Footing/Slab
Blocking&Hold Downs
Skirting
PLANNING DEPT. Separate Permit#s SEPA:
Parkin /Lighting ESA:
Landscaping SHORELINE:
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE
Inspection Type Date Accepted By
Electrical 417-4735
Construction- R.W. PW I Engineering 417-4831
Fire 417-4653
Planning 417-4750
Building 417-4815
T:Forms/Building Division/Building Permit
0f PORT^"Q CITY OF PORT ANGELES
PUBLIC WORKS & UTILITIES
•
321 EAST 5TH STREET, PORT ANGELES,WA 98362
4ea
Application Number . . . . . 14-00000743 Date 7/16/14
Application pin number . . . 592701
Property Address . . . . . . 1419 PENDLEY CT REPORT SALES TAX
ASSESSOR PARCEL NUMBER: 06-30-01-8-6-0120-0000- on your state excise tax form
Application type description RES NEW SFR
Subdivision Name . . . . . . to the City of Port Angeles
Property Use . . . . . . . . (Location Code 0502)
Property Zoning . . . . . . . RS9 RESDNTL SINGLE FAMILY
Application valuation . . . . 114302
----------------------------------------------------------------------------
Application desc
1687 SQ FT SFR
----------------------------------------------------------------------------
Owner Contractor
------------------------ ------------------------
SARAH SLOTA OWNER
2202 W 16TH St E6
PORT ANGELES WA 98363
----------------------------------------------------------------------------
Permit . . . . . . DRIVEWAY INSTALLATION
Additional desc . . DRIVEWAY AND CULVERT
Permit Fee . . . . 180.00 Plan Check Fee .00
Issue Date 7/16/14 Valuation . . . . 0
Expiration Date 1/12/15
Qty Unit Charge Per Extension
BASE FEE 180.00
----------------------------------------------------------------------------
Permit . . . . . . PUBLIC WORKS RES WATER SERV
Additional desc 3/411 DROP IN WATER METER
Permit Fee . . . . 420.00 Plan Check Fee .00
Issue Date . . . . 7/16/14 Valuation . . . . 114302
Expiration Date . . 1/12/15
Qty Unit Charge Per Extension
1.00 420.0000 EA PW WATER METER DROP IN 420.00
----------------------------------------------------------------------------
Permit . . . . . . SANITARY SEWER HOOK UP
Additional desc . .
Permit Fee . . . . 150.00 Plan Check Fee .00
Issue Date . . . . 7/16/14 Valuation . . . . 114302
Expiration Date . . 1/12/15
Qty Unit Charge Per Extension
1.00 150.0000 EA SAN SEWER HOOKUP 150.00
----------------------------------------------------------------------------
Special Notes and Comments
June 24, 2014 11:49:31 AM pbarthol.
Plan check fees for permits 14-743 and
14-742 pain on permit 14-743. No plan
review charged on 14-742 pb
July 2, 2014 7:35:05 AM rbecker.
You did not mark on your permit, if you were installing a
Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements.This permit becomes
null and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned
for a period of 180 days after the work as-commenced,or if required inspections have not been requested within 180 days from the last
inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of
laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not
presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construction.
-7/1111
Signature of Contract Authorized Agent Date Signature of Owner(if owner is builder) Date
T:\Policies\1102.15[10/08]
PERMIT INSPECTION RECORD
CALL 417-4831 FOR UTILITY INSPECTIONS. PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAWFUL TO COVER,
INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT IN A CONSPICUOUS LOCATION.
KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE
INSPECTION TYPE DATE ACCEPTED COMMENTS
YES NO
PW UTILITIES (Engineering Division)
i
WATERLINE/METER
SEWER CONNECTION
SANITARY
STORM
SITE DRAINAGE
SITE EROSION CONTROL
PARKING
SIDEWALK
CURB&GUTTER
DRIVEWAY APPROACH
BACK-FLOW DEVICE
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE
RESIDENTIAL DATE YES NO COMMERCIAL DATE ACCEPTED
YES NO
CONSTRUCTION R.W./PW/ CONSTRUCTION-R.W.
ENGINEERING 417-4831 PW/ENGINEERING
FIRE 417-4653 FIRE DEPT.
PLANNING DEPT. 417-4750 PLANNING DEPT.
BUILDING 417-4815 BUILDING
T:\Policies\1102.15[10/08]
CITY OF PORT ANGELES
PUBLIC WORKS & UTILITIES
,mss
321 EAST 5TH STREET, PORT ANGELES,WA 98362
Page 2
Application Number . . . . . 14-00000743 Date 7/16/14
Application pin number . . . 592701 REPORT SALES TAX
------------------
--------------------------------------------
Special Notes and Comments on your state excise tax form
fire or lawn sprinkler system. If you are installing either to the City of Port Angeles
one, you will need to install a backflow assembly. Location Code 0502)
If you havice any questions call Ron Becker at 360-417-4886,
fax: 360-452-4972, or E-mail: rbecker@cityofpa.us
Address numbers shall be plainly visible from the street.
Address numbers shall be a minimum of six inches high and be
of contrasting color from the background.
A full acceptance test will be required for the fire
sprinkler system.
Call for cover inspection for all sprinkler installations.
All homes in new subdivisions that are outside of the Fire
Department four-minute response area shall be equipped with
residential fire sprinkler systems that comply with the
International Fire Code (IFC) and National Fire Protection
Association (NFPA) .
July 9, 2014 8:57:30 AM sroberds.
The permit allows for a new sfr in the RS-9 w/attached
garage for total lot cov of 19% and site cov of 41%. No
land use issues anticipated.
Electrical load calculations and electrical permits are
required.
Ditches & 12" culverts will be installed to City Stanards.
See Public Works Engineering for Standards.
All SWPPP elements must be followed as this is part of a
larger plan of development (Pendley Ct) including:
3.1.1 Element #1 Mark Clearing Limits
3.1.2 Element #2 Establish Construction Access
3.1.3 Element #3 Control Flow Rates
3.1.4 Element #4 Install Sediment Controls
3.1.5 Element #5 Stabilize Soils
3.1.6 Element #6 Protect Slopes
3.1.7 Element #7 Protect Drain Inlets
3.1.8 Element #8 Stabilize Channels and Outlets
3.1.9 Element #9 Control Pollutants
3.1.10 Element #10 Control Dewatering
3.1.11 Element #11 Maintain BMPs
3.1.12 Element #12 Manage the Project
Consider applying for the City Green Infrastructure Rebate
of up to $750.00 towards the materials to install rain
garden to control roof and driveway runoff. Also rebates
available for downspout disconnections.Contact Jonathan
Boehme at 360 417-4811
All construction work within the City right of way requires
a separate Right of Way Construction application to be
completed by the contractor and approved by Public Works
Engineering prior to the start of work. A pedestrian or
traffic control plan is to be submitted for approval with
the application as necessary.
Sanitary sewer connection inspection is required by
Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes
null and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned
for a period of 180 days after the work as.commenced,or if required inspections have not been requested within 180 days from the last
inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of
laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not
presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construction.
Signature of Contractor or Authorized Agent Date Signature of Owner(if owner is builder) Date
T:\Policies\1102.15[10/081
PERMIT INSPECTION RECORD
CALL 417-4831 FOR UTILITY INSPECTIONS. PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAWFUL TO COVER,M
INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT INA CONSPICUOUS LOCATION.
KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE
INSPECTION TYPE DATE ACCEPTED COMMENTS
YES NO
PW UTILITIES (Engineering Division)
WATERLINE/METER
SEWER CONNECTION
SANITARY
STORM
SITE DRAINAGE
SITE EROSION CONTROL
PARKING
SIDEWALK
CURB&GUTTER
DRIVEWAY APPROACH
BACK-FLOW DEVICE
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE
RESIDENTIAL DATE YES NO COMMERCIAL DATE ACCEPTED
YES NO
CONSTRUCTION R.W./PW/ CONSTRUCTION-R.W.
ENGINEERING 417-4831 PW/ENGINEERING
FIRE 417-4653 FIRE DEPT.
PLANNING DEPT, 417-4750 PLANNING DEPT.
BUILDING 4174815 BUILDING
T:Tolicies\1102.15(10/081
�pOflT,N,C CITY OF PORT ANGELES
PUBLIC WORKS & UTILITIES
321 EAST 5TH STREET, PORT ANGELES,WA 98362
Page 3
Application Number . . . . . 14-00000743 Date 7/16/14
Application pin number . . . 592701 REPORT SALES TAX
------and----Comments--------
Special Notes --------------------------------------------- on your state excise tax form
Public Works prior to back fill of ditch. 24 hour advance to the City of Port Angeles
notice is required. Public Works Inspection request line (Location Code 0502).
417-4831
Trench safety per applicable laws. Temp erosion control and
surface restoration responsibility of applicant. Contact
City inspector prior to start of work @ 360 417-4831. No
attachment to sanitary sewer of stormwater roof leaders,
foundation drains, yard drains, or any other CSO
contribution is allowed.
----------------------------------------------------------------------------
Other Fees . . . . . . . . . RES UNDERGRND SERVICE FEE 770.00
SEWER SYSTEM DELV CHARGE 2260.00
STATE SURCHARGE 4.50
PW WATER SYSTEM USE FEE 2260.00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 750.00 750.00 .00 .00
Plan Check Total .00 .00 .00 .00
Other Fee Total 5294.50 5294.50 .00 .00
Grand Total 6044.50 6044.50 .00 .00
Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements.This permit becomes
null and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned
for a period of 180 days after the work as.commenced,or if required inspections have not been requested within 180 days from the last
inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of
laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not
presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construction.
Signature of Contractor or Authorized Agent Date Signature of Owner(if owner is builder) Date
T:\Policies\1102.15[10/08]
PERMIT INSPECTION RECORD
CALL 417-4831 FOR UTILITY INSPECTIONS. PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. ITIS UNLAWFUL TO COVER, ~
INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT INA CONSPICUOUS LOCATION.
KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE
INSPECTION TYPE DATE ACCEPTED COMMENTS
YES NO
PW UTILITIES (Engineering Division)
t
WATERLINE/METER
SEWER CONNECTION
SANITARY
STORM
SITE DRAINAGE
SITE EROSION CONTROL
PARKING
SIDEWALK
CURB&GUTTER
DRIVEWAY APPROACH
BACK-FLOW DEVICE
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE
RESIDENTIAL DATE YES NO COMMERCIAL DATE ACCEPTED
YES NO
CONSTRUCTION R.W./PW/ CONSTRUCTION-R.W.
ENGINEERING 417-4831 PW/ENGINEERING
FIRE 417-4653 FIRE DEPT.
PLANNING DEPT. 417-4750 PLANNING DEPT.
BUILDING 417-4815 BUILDING
TAPolicies\1102.15[10/08]
Tw,,E
CITY dF €V x.T�
11]Ew For Cit Use
Y
Permit#
W A S H I N G T 0 N , U . S .
Date Received:
321 East 51' Street
Port Angeles, WA 98362 Date Approved
P: 360-417-4817 F: 360-417-4711
permits@cityofpa.us U 9�
Building Permit Application
Project Address: cc'v
MainContact: ��5 i 2����o� s�� +��s ��Z Phone # 7!)6.0— �l a— o c>?�
!°ter r✓s V1_4 /"'tovs(,✓W lqurH-� le(T7` E-Mail:
Property Name Phone
Owner !i -:3t/'e, -
Mailing Address Email
2z�z �✓gsT G�f ��
City State Zip -
n R� nlG Ez�s L✓ 83� 3 y
Contractor Name Phone
Mailing Address Email
City State Zip
Contractor License# Expiration:
Project Value: Zoning: Tax Parcel # Lot#
$ //y 3-a _ / ,2
Type of Residential Commercial ❑ Industrial ❑ Public ❑
Permit Demolition ❑ Fire ❑ Repair ❑ Reroof(tear off/lay over) ❑
For the following,fill out both pages of permit application:
New Construction 9'__ Remodel ❑ Addition ❑ Tenant Improvement ❑
Mechanical ❑ Plumbing ❑ Other. ❑
Existing Fire Sprinkler System? Maximum height of structure Proposed Bedrooms Proposed Bathrooms
Yes ❑ No ❑
Project
Description
I have read and completed the application and know it to be true and correct.I am authorized to apply for this
permit. I understand that it is my responsibility to determine what permits are required and to obtain permits
prior to working on projects. I understand that the plan review fee is not refundable after plan review has
occurred. I understand that I will forfeit the review fee if I cancel or withdraw the application before the
permit is issued. I understand that if the permit is not issued within 180 days of receipt,the application will be
considered abandoned and the fees forfeit.
Date Print Name Signature
7/16/1 Y & UC �_ I-P7 c ar-%'
Residential Structures �—
For Office Use
Area Description(SQ FT) Existing Proposed $$value
Basement
First Floor 1o/ U0
Second Floor..
Covered'Deck/Porch/Entry -3 Y�Z
Deck .9
Garage 3 7j
Carport
Other(describe)
Area Totals /697
Commercial Structures
For Office Use
Area Descriptions (SQ FT) Existing Proposed $$Value
Existing-Structure(s)
Proposed Addition
Tenant Improvement?
Other work(describe)
Area Totals
Lot/Site Coverage Calculations
Footprint(SQ FT) of all Structures: Lot Size: %Lot Coverage
L/,8 7 900 7 /9, 7
SQ FT Site coverage(all impervious+ %Site Coverage
structures) 1/0,
Mechanical Fixtures
Indicate how many of each type of fixture to be installed or relocated as part of this project.
Air Handler Size: # Haz/Non-Haz Piping #of Outlets:
Appliance Vent # Heater(Suspended,Floor,Recessed wall) # 3
Boiler/Compressor Size: # Heating/Cooling appliance #
repair/alteration
Evaporative Cooler(attached,not # Pellet Stove/Wood-burning/Gas #
portable) Fireplace Gas Stove Gas Cook Stove/Misc.
Fuel Gas Piping #of Outlets: Ventilation Fan,single duct # . 3
Furnace Heat Pu Size: # Ventilation System #
Forced Air nit
Plumbing Fixtures
Indicate how many of each type of fixture to be installed or relocated
Plumbing Traps # Fuel gas piping #of Outlets:
Water Heater # Medical gas piping #of Outlets:
Water Line # Vent piping #
Sewer Line # / Industrial waste pretreatment #
interceptor
Other describe
T:\BUILDING\APPLICATION FORMS\BUILDING PERMIT 081212.DOCX
OF PORT'J'%,�1
.r
PRESCRIPTIVE APPROACH-SIMPLE FORM
For the Washington State Energy Code(WSEC) 2009 Edition.
Climate.Zone 1
MY GOVERNMENT Site Information: - Building Department Use Only:
Lot: *T-1 a / Pew DL gy %Permit #
Address: j y/ /9&n/,DLey coy r� Notes:
City: r0 9--f ygid
State: &/e Zip:
Contact: `-
Phone: 360 - 007 f
Phone 2: 360-
FAX:
60-FAX:
WSEC Table 6-1
PRESCRIPTIVE REQUIREMENTS FOR SINGLE-FAMILY RESIDENTIAL OR DUPLEX
CLIMATE ZONE 1
(Unlimited Glazing Option Only)
Glaiing ,, Glazing U Factor x Door �� � Vaulted fntenor
Wall -Wall
Exterior
Option', Area%of _ U -Ceiling Abovfe Floor Slab on-
FloorVertical ' ;O`verhead Factor , ` 'Ceiling GPade Belovtr� Below Concrete.
R-49
III
or R-21 R-21 R-30/ R-10 Unlimited 0.30 0.50 0.20 R-38 R-38 int T13 R-10 U=0.029 2'
adv
This Project complies with the following:
The project is a single-family residence or duplex.
The project is a wood frame OR all of the insulation is interior or exterior of the framing.
All building components meet the requirements listed above.
The project will meet all other provisions of the WSEC and VIAQ.
The Project will take advantage of the following exceptions to the prescriptive option.
❑ 602.6 Exception 2. One unlabeled or untested exterior swinging door, 24 sq.ft. or less, may be
installed per unit for ornamental, security, or architectural purposes.
Location of the door taking this exception:
❑ 602.6 Exception 2. If a door is mostly glass, it should meet the requirement of the vertical
glazing U-factor listed above.
Location of the door(s)taking exception: .
1—
Type of Heat Source: Dyef-J_2_5s 1J- 10yn_P 3 o„isan 5W ws
T:Forms/Building Division/Prescriptive Approach-Simple Form
cp.,v�c Electrical Information Form
e Public Works&Utilities Department(360)417-4700
City Electrical Inspector(360)417-4735
Please complete and return to Public Works&Utilities Department 3k
• • • •
Permanent service: Name:
Name and address of party Street:
responsible for permanent City I State I ZIP:
service billing? Daytime Phone: Home Phone:
FRIMIQQ9,M711111111 (if other than above)
Site contact: Name: ✓2c.��� /'rjcCoPP J Title: CDA)Sl— 5 V��?vispYL d/9 ,
Daytime Phone: '.3G p1a - 0o7
Contractor: Name: Company:
Daytime Phone:
Electrician: Name: Company:
Daytime Phone:
Excavator: Name: Company:
Daytime Phone:
' ❑Existing ew
ingle-family residence ❑M Iti-family residence;#of units
❑Commercial L7Subdivision; #of lots 0
❑Overhead service El General service
E
service ❑Other:
• • • • Description of work: r.�-✓
Street address/lot number. /(- / f' f+✓(7� Co a ,
uSOT
Nearest cross street: t,)i;5 �/ n> ,
Desired connection date:
Electrical transformer serving property is: ❑on a pole on the ground
Total square footage: $7 sq.ft. Main disconnect size: v amps
Voltage: 20/240 1ph ❑120/208 3ph ❑277/480 3ph
❑120/240 3ph ❑480 3W 3ph ❑ Other
Standard residential loads(Lighting, refrigerator, dishwasher,washer)
Check all that apply: ❑,A/C (_ton) MR-ange/Oven ❑Hot Tub
L'�C,othes Dryer [�Heating ❑Pumps �Hp)
❑No Load Change (Water Heater ❑Elevator C_Hp) ❑Other
• ' • • Please provide a copy of the following:
'Detailed plot plan (.dwg or.dxf format mandatory for subdivisions).
'Electrical one-line drawing showing the service entrance panel and location.
'Connected load data.
'Size and locked rotor amps of all motors over 50hp.
Applicant's Signature: Date:
MAIL OR DELIVER COMPLETED FORM TO: 321 E 5TH STREET; PORT ANGELES, WA 98362
FAX TO: 360-417-4711
WS
Information for^.;.xls
WF
N:''r'WKS1IGHT`.rNGR\?l
G
Lr
77
HM�el
_ ...._.........
--
Qj
J to Plan
r=20.0'
t*4olzlu
PORT ANC,`EI. b.SVA 98363
couNTY of cLALL4m
PENDL[---Y COUIZT LOT 12
LOT COVCR64C. 1687/9007F 18.79
51TE COVERAGE 3669/9007F = ,40.7%
LIOUSE.STYLE:Tflr- NuL-5
cqj
10,20'
_....... -
'Z31`.
DIOF I X40'
os
77 a`
i
I
33'
149-I"
I
y t 45V 4'26-
1S'
KIP,t1p
bite Ilan
r=20.0
I�� lF�L�GoUf�'"' NoRl11 �
PORT ANGELL6.VA 98363
couNTY OF CLALLAM
PC NDLEY COUIZT LOT 12
LOT CO\/I=RAG'[ 1687/9007F- 18.796
6ITL COVEI24G'E 3669/9007F= 40.7%
i lOUSE bTYLE:Tfl['NEIL-6`
:
}
1.7
,
um
l' VM AS
ol
alN
--
- --
r-
- � Z
T— ; T
—
U � � -- -- - -- - - -- -- -
� I T
,
I I
,
a
:
Gn
i
-- — —
I :
:
t
,
t I �
t
t
:
:
: -
,
:
i � I
,
!
1
1 K4
--- - - - -- -- - -' - - - - -
- r
1
;
' I
i V� � X ti4 `7-`scI -- —, -- - i
,
_ - - --rill
,
i
— F vckti '
-- — (= -
's
,
_77-001-yo,
yAl, U � ;i/ZI SaoSw
,
i ,
s
" y r
!
i 1-0-7-
----------
ST
,
-
i _
t
�Nc-
-1 -7
U6--t
-----------
-------------4
---------------
7 V
1124 T
1 1
"17
----------
41-4-
-4j,
LlIv
---------- -------------
�- 'Ute ' �- C�`� �`�tx_ ��� �1 f (� '' ��
Ic-
j ' I
i
� r
_ t
ZLO
car = 1
8 ,�
T _ 71
_
7111
44
L Sip
l r
I
:
- - --
'
`(per
C�r'v�- . (
�
�C C17`f
1 '
53 _
t t ( Z
---- -' -� 17 �X Ly!
i
: I
,
r
I 1
1ST ! YT
-1
ZN
: - I
I + f
I
1..
I
r :
2p
-
I
I 1
7T
-- I-OiY
( j-
-- ---
8Ac�-+-` '6n1S — 3Zd
:
I
-
,
,
__ - __
I :
,
CCS [
I
- - - -- '
A--17
Y
i _
I -
----------- -- - -
,
1
III
i"
,
-- - - -- -
:
Off'
(--z-L
S-Z - Z�z� �� = �� b - 1 s
- - -
� `
:
- -- - -
T
Z T161-
:
IU
:
:
:
� T
1
-
'� -
:
�f
:
L
fff
.� 1. �✓l%�'r�`
MECAWind Version 2 . 1 . 0 . 5 per ASCE 7-05
Developed by MECA Enterprises, Inc. Copyright 2012 www.mecaenterprises.com
Date 10/11/2012 Project No. 12176
Company Name ZENOVIC 6 ASSOCIATES, INC. Designed By SRH
Address 301 EAST 6TH STREET, SUITE 1 Description : 28x40 SFR
City PORT ANGELES Customer Name PENINSULA HOUSING AUTHORITY
State WA Proj Location CLALLAM COUNTY, WA
File Location: X:\12176 HOUSING AUTHORITY\ENGR\Structual\28x40 SFR.wnd
Detailed Wind Load Design(Method 2) per ASCE 7-05
Basic Wind Speed(V) = 100.00 mph Structure Type = Building
Structural Category = II Exposure Category = C
Natural Frequency = N/A Flexible Structure = No
Importance Factor = 1.00 Kd Directional Factor = 0.85
Alpha = 9.50 Zg = 900.00 ft
At = 0.11 Bt = 1.00
Am = 0.15 Bm = 0.65
Cc = 0.20 1 = 500.00 ft
Epsilon = 0.20 Zmin = 15.00 ft
Slope of Roof = 4 : 12 Slope of Roof(Theta) = 18.45 Deg
Ht: Mean Roof Ht = 10.34 ft Type of Roof = Gabled
RHt: Ridge Ht = 12.67 ft Eht: Eave Height = 8.00 ft
OH: Roof Overhang at Eave= .00 ft Roof Area = 1181.00 ft^
2
Bldg Length Along Ridge = 40.00 ft Bldg Width Across Ridge= 28.00 ft
Gust Factor Category I Rigid Structures - Simplified Method
Gustl: For Rigid Structures (Nat. Freq.>l Hz) use 0.85 = 0.85
Gust Factor Category II Rigid Structures - Complete Analysis
Zm: 0.6*Ht = 15.00 ft
lzm: Cc* (33/Zm)^0.167 = 0.23
Lzm: 1* (Zm/33)^Epsilon 427.06 ft
Q: (1/(1+0.63* ( (B+Ht) /Lzm) ^0.63) ) ^0.5 - 0. 94
Gust2: 0.925* ( (1+1.7*lzm*3.4*Q) /(1+1.7*3.4*lzm) ) = 0.89
Gust Factor Summary
Not a Flexible Structure use the Lessor of Gustl or Gust2 = 0.85
Figure 6-5 Internal Pressure Coefficients for Buildings, GCpi
GCPi : Internal Pressure Coefficient = +/-0.18
Figure 6-6 External Pressure Coefficients
Cp - Loads on Main Wind-Force Resisting Systems(Method 2)
eta
h
fig
L
z
Id _� B
B
Kh: 2.01* (Ht/Zg) ^(2/Alpha) = 0.85
Kht: Topographic Factor (Figure 6-4) = 1.00
Qh: .00256* (V)^2*I*Kh*Kht*Kd = 18.47 psf
Cpww: Windward Wall Cp(Ref Fig 6-6) = 0.80
Roof Area = 1181.00 ft^2
Reduction Factor based on Roof Area = 0.80
MWFRS-Wall Pressures for Wind Normal to 40 ft wall (Normal to Ridge)
Wall Cp Pressure Pressure
+GCpi (psf) -GCPi (psf)
--------------- ------ ----------- -----------
Leeward Wall -0.50 -11.18 -4.53
Side Walls -0.70 -14.32 -7.67
Wall Elev Kz Kzt qz Press Press Total Shear Moment
ft psf +GCpi -GCPi +/-GCPi Kip K-ft
--------------------------------------------------------------------------------
Windward 12.67 0.85 1.00 18.47 9.24 15.89 20.41 10.34 65.53
Note: 1) Total = Leeward GCPi + Windward GCPi
2) Shear and Moment are sum of forces (Leeward+Windard) acting on bldg walls.
Note that the shear & moment don't consider loads on roof or end gable.
Roof Location Cp +GCpi(psf) -GCpi(psf)
----------------------- ------- ---------- ----------
Windward - Min Cp -0.42 -9.92 -3.27
Windward - Max Cp 0.05 -2.54 4.11
Leeward Perp to Ridge -0.57 -12.27 -5.62
Overhang Top (Windward) -0.42 -6.59 -6.59
Overhang Top (Leeward) -0.57 -8.95 -8.95
Overhang (Windward only) 0.80 12.56 12.56
MWFRS-Wall Pressures for Wind Normal to 28 ft wall (Along Ridge)
Wall Cp Pressure Pressure
+GCpi (psf) -GCpi (psf)
s
--------------- ------ ----------- -----------
Leeward Wall -0.41 -9.83 -3.18
Side Walls -0.70 -14.32 -7.67
Wall Elev Kz Kzt qz Press Press Total Shear Moment
ft psf +GCpi -GCpi +/-GCpi Kip K-ft
--------------------------------------------------------------------------------
Windward 12.67 0.85 1.00 18.47 9.24 15.89 19.07 6.76 42.85
Note: 1) Total = Leeward GCPi + Windward GCPi
2) Shear and Moment are sum of forces (Leeward+Windard) acting on bldg walls.
Note that the shear & moment don't consider loads on roof or end gable.
Roof - Dist from Windward Edge Cp Pressure Pressure
+GCpi(psf) -GCpi(psf)
--------------------------------- ------ ---------- ----------
0.0 ft to 5.2 ft -0.90 -17.46 -10.81
5.2 ft to 10.3 ft -0.90 -17.46 -10.81
10.3 ft to 20.7 ft -0.50 -11.18 -4.53
20.7 ft to 40.0 ft -0.30 -8.04 -1.39