PREPARED 5/25/16, 8:20:49 INSPECTION TICKET ,PAGE 7
CITY OF PORT ANGELES INSPECTOR: JAMES LIERLY DATE 5/25/16
---' -----------—---------------------------------------------
ADDRESS . : 1428 PENDLEY CT SUBDIV:
CONTRACTOR : PHONE :
OWNER BILL WRIGHT PHONE : (360) 477-6609
PARCEL 06-30-01-8-6-0040-0000-
APPL NUMBER: 15-00000414 RES NEW SFR
- ------------------------------------------------------ ---
PERMIT: BPR 00 BUILDING PERMIT - RESIDENTTAT•
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
--------------------------------------------------------------------------------------
BL1 01 10/30/15 JLL BLDG FOUNDATION FOOTING
10/30/15 AP October 30, 2015 10:13:16 AM jlierly.
bruce 912-0079
October 30, 2015 4:01:41 PM jlierly.
BL2 01 11/02/15 JLL BLDG FOUNDATION STEM WALL
11/02/15 AP November 2, 2015 8:15:09 AM jlierly.
Tommy
November 2, 2015 3:59:25 PM jlierly.
DSD O1 11/13/15 JLL BLDG DOWN SPOUT DRAINS
11/13/15 AP November 13, 2015 9:41:36 AM jlierly.
Bruce
November 13, 2015 12:46:28 PM jlierly.
BFF O1 11/23/15 PB BLDG FLOOR FRAMING
11/24/15 AP November 23, 2015 10:13:54 AM pbarthol.
November 24, 2015 9:23:13 AM pbarthol.
BEXS O1 12/23/15 JLL BLDG EXTERIOR SHEETING
1/04/16 AP December 23, 2015 9:08:27 AM jlierly.
bruce 912-0079
January 4, 2016 4:22:40 PM jlierly.
BAIR O1 2/04/16. JLL BLDG AIR SEAL
2/04/16 AP February 4, 2016 8:33:10 AM jlierly.
February 4, 2016 4:12:30 PM jlierly.
BL3 01 2/04/16 JLL BLDG FRAMING
2/04/16 AP February 4, 2016 8:33:26 AM jlierly.
February 4, 2016 4:12:30 PM jlierly.
BLI O1 2/12/16 JLL BLDG INSULATION
2/12/16 AP February 12, 2016 9:12:14 AM jlierly.
Bruce 912-0079
February 12, 2016 4:53:24 PM jlierly.
FD99 01 5/16/16 MCS FIRE DEPARTMENT FINAL
5/16/16 AP May 16, 2016 2:39:54 PM msanders.
May 16, 2016 2:41:58 PM msanders.
BL99 01 5/25/16 J BLDG FINAL
May 24, 2016 12:08:06 PM jlierly.
Bruce 912-0079
---------------------- - -------
PERMIT: ME 00 MECHANE41M.-
RMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
-- -------—--- --- -------------- --- ----—-—------ -----
ME99 01 5/25/16 MECHANICAL FINAL
May 24, 2016 12:08:43 PM jlierly.
--- - --------------------- ---------------
PERMIT: PL 00 PLUMBIN P RMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
-—-----------------------------—- CONTINUED ONTO NEXT PAGE -----------------------------------
- CITY OF PORT ANGELES
eA� DEPARTMENT OF COMMUNITY& ECONOMIC DEVELOPMENT- BUILDING DIVISION
321 EAST 5TH STREET, PORT ANGELES, WA 98362
Application Number . . . . . 15-00000414 Date 5/08/15
Application pin number . . . 876202
Property Address . . . . . . 1428 PENDLEY CT
ASSESSOR PARCEL NUMBER: 06-30-01-8-6-0040-0000- REPORT SALES TAX
Application type description RES NEW SFR on your state excise tax form
SubdProperty
Name . . . . . . to the City of Port Angeles
Pro ert Use ,,Ie 0502)
Property Zoning . . . . . . . RS9 RESDNTL SINGLE FAMILY (Location valuation . . . . 117568 (Location COd
Application desc
1240SFSFR W/64SF PORCH, 380SF GARAGE 3BED 2 BATH
----------------------------------------------------------------------------
Owner Contractor
BILL WRIGHT OWNER
1428 PENDLEY COURT
PORT ANGELES WA 98363
(360) 477-6609
----------------------------------------------------------------------------
Permit . . . . . . BUILDING PERMIT -RESIDENTIAL
Additional desc . . 1620SF SFR 3BEDROOM 2BATHROOM
Permit Fee .. . . . 1121.05 Plan Check Fee 728.68
Issue Date . . . . 5/08/15 Valuation 117568
Expiration Date 11/04/15
Qty Unit Charge Per Extension
BASE FEE 1020.25
18.00 5.6000 THOU BL-100,001-500K (5.60 PER K) 100.80
------------------- -- ---------------------------------
Permit . . . . MECHANICAL PERMIT
Additional desc SFR MECHANICAL
Permit Fee . . . . 141.60 Plan Check Fee .00
Issue Date 5/08/15 Valuation 0 �Ll
Expiration Date 11/04/15
Qty Unit Charge Per Extension
BASE FEE 50.00
1.00 14.8000 EA ME-FURN/HP/FAU < OR = 5 TON 14.80
3.00 7.2500 EA ME-VENT FAN (SINGLE, DUCT) 21.75
1.00 10.6500 EA ME-HOOD/DUCT-MECH. EXHAUST 10.65
3.00 14.8000 EA ME-HEATER(SUSP/WALL/FLOOR-MTD) 44.40
----------------------------------------------------------------------------
Permit . . . . . . PLUMBING PERMIT
Additional desc . . SFR PLUMBING
Permit Fee . . . . 135.00 Plan Check Fee .00
Issue Date . . 5/08/15 Valuation . . . . 0
Expiration Date 11/04/15
Qty Unit Charge Per Extension
BASE FEE 50.00
5.00 7.0000 EA PL-PLUMBING TRAP 35.00
1.00 7.0000 EA PL-WATER LINE 7.00
3.00 7.0000 EA PL-DRAIN VENT PIPING 21.00
Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes
null and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned
for a period of 180 days after the work has commenced, or if required inspections have not been requested within 180 days from the
last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions
of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does
not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construction.
J 6 fS j 60ZL)C"_ Meeolr /
Date Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder)
T:Forms/Building Division/Building Permit
BUILDING PERMIT INSPECTION RECORD
PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS—
Building Inspections 417-4815 Electrical Inspections 417-4735
Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886
IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED.
POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE.
Inspection Type Date Accepted By Comments
FOUNDATION:
Footings
Stemwall
Foundation Drainage/Downspouts
Piers
Post Holes(Pole Bldgs.)
PLUMBING:
Under Floor/Slab
Rough-In
Water Line Meter to Bldg)
Gas Line
Back Flow/Water FINAL Date Accepted b
AIR SEAL:
Walls
Ceiling
FRAMING:
Joists/Girders/Under Floor
Shear Wall/Hold Downs
Walls/Roof/Ceiling
Drywall Interior Braced Panel Only)_
T-Bar
INSULATION:
Slab
Wall/Floor/Ceiling
MECHANICAL:
Heat Pum /Furnace I FAU/Ducts
Rough-In
Gas Line
Wood Stove/Pellet/Chimney
Commercial Hood/Ducts FINAL Date Accepted b
MANUFACTURED HOMES:
Footing/Slab
Blocking&Hold Downs
Skirting
PLANNING DEPT. Separate Permit#s SEPA:
Parkin /Lighting ESA:
Landscaping SHORELINE:
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE
Inspection Type Date Accepted By
Electrical 417-4735
Construction- R.W. PW /Engineering 417-4831
Fire 417-4653
Planning 417-4750
Building 417-4815
T:Forms/Building Division/Building Permit
-^ CITY OF PORT ANGELES
DEPARTMENT OF COMMUNITY & ECONOMIC DEVELOPMENT- BUILDING DIVISION
321 EAST 5TH STREET, PORT ANGELES, WA 98362
Page 2
Application Number . . . . . 15-00000414 Date 5/08/15
Application pin number . . . 876202 REPORT SALES TAX
Qty Unit Charge Per Extension on your state excise tax form
1.00 15.0000 EA PL-SEWER LINE 15.00
1.00 7.0000 0000 EA PL-WATER HEATER 7.00 to the City of Port Angeles
-- ---_ -------- ------- -- (Location Code 0502)
Special Notes and Comments
April 21, 2015 4:36:34 PM pbarthol.
Plan review paid on this permit for
permits 15-414, 15-415, 15-416.These
three projects used the same plans, so
only one plan review was charged.
Address numbers shall be plainly visible from the street.
Address numbers shall be a minimum of six inches high and be
.of contrasting color from the background.
All homes in new subdivisions that are outside of the Fire
Department four-minute response area shall be equipped with
residential fire sprinkler'.systems that comply with the
International Fire Code (IFC) and National Fire Protection
Association (NFPA) .
Electrical load calculations and electrical permits are
required.
Ditches & 12" culverts will be installed to City Stanards.
See Public Works Engineering for Standards.
1) Standard Stormwater Comments for temporary erosion
control. This is part of a larger plan of development,
greater than 1 acre.
This includes
1. Mark Clearing Limits
2. Establishing Construction Access
3. Control Flow Rates
4. Install sediment controls BMPs.
5. Stabilize exposed soils
6. Protect slopes from erosion
7. Protect drain inlets
8. Control pollutants including but not limited to spills,
concrete wash out, exposed aggregate processes, concrete
grinding and saw cut waste water. A marked contained
concrete washout area is required may not discharge truck
wash water to sewer, ditches or ground.
9. Maintain temporary and permanent erosion control BMPS
during project
10. Update TESC plans as changes take place .
No downspouts shall be connected to sanitary sewer.
Also include: Consider applying for the City Green
Infrastructure Rebate of up to $750 towards the materials to
install a rain garden to control roof or driveway runoff.
Separate Right of Way Construction permit required for
driveway and culverts.
Trench safety per applicable laws. Temp erosion control and
surface restoration responsibility of applicant. Contact
City inspector prior to start of work @ 360 417-4831. No
attachment to sanitary sewer of stormwater roof leaders,
Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes
null and void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned
for a period of 180 days after the work has commenced, or if required inspections have not been requested within 180 days from the
last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions
of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does
not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construction.
Date Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder)
T:Forms/Building Division/Building Permit
i "3a
BUILDING PERMIT INSPECTION RECORD
— PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS—
Building Inspections 417-4815 Electrical Inspections 417-4735
Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886
IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED.
POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE.
Inspection Type Date Accepted By Comments
FOUNDATION:
Footings
Stemwall
Foundation Drainage/Downspouts
Piers
Post Holes(Pole Bldgs.)
PLUMBING:
Under Floor/Slab
Rough-In
Water Line(Meter to Bldg)
Gas Line
Back Flow/Water FINAL Date Accepted b
AIR SEAL:
Walls
Ceiling
FRAMING:
Joists/Girders/Under Floor
Shear Wall/Hold Downs
Walls/Roof/Ceiling
Drywall Interior Braced Panel Only)_
T-Bar
INSULATION:
Slab
Wall/Floor/Ceiling
MECHANICAL:
Heat Pum /Furnace/FAU/Ducts
Rough-In
Gas Line
Wood Stove/Pellet/Chimney
Commercial Hood/Ducts FINAL Date Accepted b
MANUFACTURED HOMES:
Footing/Slab
Blocking&Hold Downs
Skirting
PLANNING DEPT. Separate Permit#s SEPA:
Parkin /Lighting ESA:
Landscaping SHORELINE:
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE
Inspection Type Date Accepted By
Electrical 417-4735
Construction- R.W. PW /Engineering 417-4831
Fire 417-4653
Planning 417-4750
Building 417-4815
T:Forms/Building Division/Building Permit
CITY OF PORT ANGELES
DEPARTMENT OF COMMUNITY & ECONOMIC DEVELOPMENT- BUILDING DIVISION
' 321 EAST 5TH STREET, PORT ANGELES, WA 98362
Page 3
Application Number . . . . . 15-00000414 Date 5/08/15
Application pin number 876202 _ ----- REPORT SALES TAX
Special Notes and Comments on your state excise tax form
foundation drains, yard drains, or any other CSO
contribution is allowed. to the City of Port Angeles
Sanitary sewer connection inspection is required by (Location Code 0502)
Public Works prior to back fill of ditch. 24 hour advance
notice is required. Public Works Inspection request line
417-4831
The contractor making the connection to an existing water
meter is responsible to adjust water meter depth so that
there is a minimum of 4 to 6 inches of clearance between the
bottom of the meter box lid and the top of the meter at
finish grade.
Construct driveway to City Standards. Concrete with exposed
aggregate or other non-standard finishes(including colors or
dyes)are not allowed in the City road right of way. Broom
finish only. An inspection-.Py Public Works Engineering is
required prior to pouring concrete. Public Works inspection
request line 417-4831.
----------------------------------------------------------------------------
Other Fees . . . . . . RES UNDERGRND SERVICE FEE 770.00
SEWER SYSTEM DELV CHARGE 2260.00
STATE SURCHARGE 4.50
PW WATER SYSTEM USE FEE 2260.00
-- -------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ---------- _
Permit Fee Total 1397.65 1397.65 .00 .00
Plan Check Total 728.68 728.68 .00 .00
Other Fee Total 5294.50 5294.50 .00 .00
Grand Total 7420.83 7420.83 .00 .00
Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes
null and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned
for a period of 180 days after the work has commenced, or if required inspections have not been requested within 180 days from the
last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions
of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does
not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construction.
Date Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder)
T:Forms/Building Division/Building Permit
BUILDING PERMIT INSPECTION RECORD
— PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS--
Building Inspections 417-4815 Electrical Inspections 417-4735
Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886
IT IS UNLAWFUL TO COVER,INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED.
POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE.
Inspection Type Date Accepted By Comments
FOUNDATION:
Footings
Stemwall
Foundation Drainage/Downspouts
Piers
Post Holes(Pole Bldgs.)
PLUMBING:
Under Floor/Slab
Rough-In
Water Line Meter to Bldg)
Gas Line
Back Flow/Water FINAL Date Accepted b
AIR SEAL:
Walls
Ceiling
FRAMING:
Joists/Girders/Under Floor
Shear Wall/Hold Downs
Walls/Roof/Ceiling
Drywall Interior Braced Panel Only)
T-Bar
INSULATION:
Slab
Wall/Floor/Ceiling
MECHANICAL:
Heat Pum /Furnace/FAU/Ducts
Rough-In
Gas Line
Wood Stove/Pellet/Chimney
Commercial Hood/Ducts FINAL Date Accepted b
MANUFACTURED HOMES:
Footing/Slab
Blocking&Hold Downs
Skirting
PLANNING DEPT. Separate Permit#s SEPA:
Parkin /Lighting ESA:
Landscaping SHORELINE:
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE
Inspection Type Date Accepted By
Electrical 417-4735
Construction- R.W. PW /Engineering 417-4831
Fire 417-4653
Planning 417-4750
Building 417-4815
T:Forms/Building Division/Building Permit
rtY = For City Use
¢.
CITY OF
k:- Permit# 5
W A s H I -T 0 N, U. S. DkPICATION
ceived:
321 E 51h Street jproved
OQ
Port Angeles,WA 9836 1�
P:360-417-4817 F:360-417-4711
Email:permits@cityofpa.us BUILDING PERMIT
Project Address: 1428 Pendley Court Port Angeles, WA 98363
Phone:360-912-0079
Prima Contact: PHA C nstruction Supervisor Email:bmccoppen@peninsulapha.org
Name ill Wright Phone360-477-6609
Property Mailing Address 1305 E 1 st Street#20 Email billawright@gmail.com
Owner
city Port Angeles State WA zip 98362
Name Owner/Builder Phone
Contractor Address Email
Information city State zip
Contractor License# Exp.Date:
Legal Description: Zoning: Tax Parcel# Project Value: (materials and labor)
Jor 4 KS cl �04-, 000 t ?&o o43 $ 117,568
Residential 8 Commercial ❑ Industrial ❑ Public ❑
Permit Demolition ❑ Fire ❑ Repair ❑ Reroof(tear off/lay over) ❑
Classification For the following, fill out both pages of permit application:
(check New Construction 8 Exterior Remodel ❑ Addition ❑ Tenant Improvement ❑
appropriate) Mechanical ❑ Plumbing ❑ Other ❑
Fire Sprinkler System Proposed Irrigation System Proposed orProposed Bathrooms Proposed Bedrooms
or Existing? Yes ❑ No D Existing? Yes ❑ No 1] 2 3
In addition to standard hard copy submittals please send a PDF copy of all Stormwater plans and Engineering to
M2Aw.stormwater@—ciqofpa.us
Project Description IlVL-w single family residence with attached)garage
lzite I L-w single family residence with attached)garage
/(010 0126 rH r -
Is project in a Flood Zone: Yes ❑ No8 Flood Zone Type:
If in a Flood Zone,what is the value of the structure before proposed improvement? $
I have read and completed the application and know it to be true and correct. I am authorized to apply for
this permit and understand that it is my responsibility to determine what permits are required and to
obtain permits prior to work. I understand that plan review fees are not refundable after review has
occurred. I understand that I will forfeit review fees if I withdraw the application before the permit is
issued. I understand that if the permit is not picked up/issued within i8o days of submittal,the application
will be considered abandoned and the fees will be forfeited.
Date Print Name Signature
� 1
Residential Structures
Existing Proposed Construction For Office Use
Area Descriptions(SQ FT) Floor area Floor area $Value new area
Basement
First Floor 1240 $105,400.00
Second Floor
Covered Deck/Porch/Entry 64 $768.00
Deck(over 30"or a° floor)
Garage 380 $11,400.00
Carport
Other(describe)
Area Totals 1620 $117,568.00
Commercial Structures
Area Descriptions(SQ FT) Existing Proposed Construction For Office Use
Floor area Floor area $Value new area
Existing Structure(s)
Proposed Addition
Tenant Improvement?
Other work(describe)
Site Area Totals
Lot/Site Coverage Calculations
Lot Size (sq ft) Lot Coverage (sq ft)foot print of %Lot Coverage (Total lot cov-lot size) Max Bldg Height
9046 all structures sq ft 18.6
Site Coverage(Sq Ft of all impervious) %of Site Coverage(total site cov=lot size)
2111 23.3
Mechanical Fixtures
Indicate how many of each type of fixture to be installed or relocated as part of this project.
Air Handler Size: # Haz/Non-Haz Piping Outlets:
Appliance Exhaust Fan # Heater(Suspended,Floor,Recessed wall) #
3
Boiler/Compressor Size: # Heating/Cooling appliance #
repair/alteration
Evaporative Cooler(attached,not # Pellet Stove/Wood-burning/Gas #
portable) Fireplace/Gas Stove/Gas Cook Stove/Misc.
Fuel Gas Piping #of Outlets: Ventilation Fan,single duct #
49
Furnace/Heat Pump/ Size: # Ventilation System #
Forced Air Unit 112k BTU 1
Plumbing Fixtures
Indicate how many of each type of fixture to be installed or relocated
Plumbing Traps # Water Heater #
s
Plumbing Vent piping # Medical gas piping #of Outlets:
Water Line # Fuel gas piping #of Outlets:
Sewer Line # Industrial waste pretreatment
1 interceptor Grease Trap) Size
Other(describe):
T:\BUILDING\APPLICATION FORMS\Current BP Application\Building Permit 4-17-13.docx
Prescnpfive Energy Code Compliance for All Climate Zones in::Washington
Pro/ect lnformahon Contact Information
Bi11Wnght y ' fa ;. enirisula ousingAuthanty ,
1428 Pendley Court �� � 2603 Sran"cisme
Port`Angeles WA 98363. x Por geles W.1A 98362
This project will use the requirements of the Prescriptive Path below and incorporate the
the minimum values listed. In addition, based on the size of the structure,the appropriate
number of additional credits are checked as chosen by the permit applicant.
Authorized Representative Date
All Climate Zones
_.
R-Valuea U-Factora
Fenestration U-Fac#orb - n/a 0.30
Skylight U-Factor n/a 0.50
Glazed Fenestration SHGCb a n/a n/a
Ceiling 49' 0.026
Wood Frame Wall"k,' 21 int 0.056
Mass Wall R-Value' 21/21h 0.056
Floor 309 0.029
Below Grade Wall`,k 10/15/21 int+TB 0.042
Slab, R-Value&Depth 10, 2 ft n/a
*Table R402.1.1 and Table R402.1.3 Footnotes included on Page 2.
Each dwelling unit in one and two-family dwellings and townhouses,as defined in Section 101.2 of the
International Residential Code shall comply with sufficient options from Table R406.2 so as to achieve the
following minimum number of credits:
Ell.Small Dwelling Unit: 0.5 points
Dwelling units less than 1500 square feet in conditioned floor area with less than 300 square feet of fenestration
area. Additions to existing building that are less than 750 square feet of heated floor area.
F1 2. Medium Dwelling Unit: 1.5 points
All dwelling units that are not included in#1 or#3, including additions over 750 square feet.
El 3. Large Dwelling Unit: 2.5 points
Dwelling units exceeding 5000 square feet of conditioned floor area.
❑4. Dwelling unit other than one and two-family dwellings and townhouses: Exempt
As defined in Section 101.2 of the International Residential Code
Table R406.2 Summa
_. ry:
Option . :Description Credit(s).
1a Efficient Building Envelope 1a 0.5 ❑
lb Efficient Building Envelope lb 1.0 ❑
1c Efficient Building Envelope 1c 2.0 ❑
2a Air Leakage Control and Efficient Ventilation 2a 0.5. ❑
2b Air Leakage Control and Efficient Ventilation 2b 1.0 ❑
2c Air Leakage Control and Efficient Ventilation 2c 1.5 ❑
3a High Efficiency HVAC 3a 0.5 ❑
3b High Efficiency HVAC 3b 1.0 ❑
3c High Efficiency HVAC 3c 2.0 ❑
3d High Efficiency HVAC 3d 1.0 P-1 1.0
4 High Efficiency HVAC Distribution System 1.0 ❑
5a Efficient Water Heating 0.5 ❑
5b Efficient Water Heating 1.5 ❑
6 Renewable Electric Energy 0.5 *1200 kwh 0.0
Total Credits:. 1.00
*Please refer to Table R406.2 for complete option.:descriptions
http://www:enorgy.wsu.edu/D6cument§/Tablo 406 2. Er ergV Credits '2012.:WSEC:pdf
V.y,-
43 0 25
41Dj rp ! j
16 6 17 8 2 33 X �a� 2. '16 28 ?�`j�trf
27
17 3223 0 15 .22
.2 28 2 130 Q
32
1$ 31 14
32 32 1;M7 d
ee
2 30 29 71 8 23 0
4 `� 3,13 5
l/ Joh 321 0 1322 /
V s1 t
21 a G�� 2405 31 0
Qa 4 �� 26 31
41 1 0 11 5 8
06 20
3 6 f 33 1323
1 910 27 1320
28>: 719 9
z 33 3 0
5 41. g_ 10
14 :1 292 Q` �18 2
12 a .z / O �fh, ` 5 Z 7 n C tt
14 s 31 at.
2 16
31 G13
13
i �7 4 12 �\ 15 3 3
�Jp�5 14 11 26
19
025
1 218
2891
1 On �
230 9 8 c a 1,
1,x28 Q'
16
13 14 , / 91 9 / 4092 416
0
15 �
12 622 11 110 / 73
50 f�to 30 2301 76 315 1112 „ 14 2
1, '{114
15 hsf 34
30 1 131 1
1511
. 220 32 12
01� 30
2
: 2 272/ 1 9
30 2 '; 9 4 y
j 10 �3 10
i 71
2202 20 f 11 2
i j 1 12 \
13
2 14 ` .
y 20 62 62 / 13 /` j 11 15 \t
2301 ,'� � .,
43 244
NORTH
SETBACK LINES
Ul SITE PLAN
1428 PENDLEY COURT
PORT ANGELES, WA
PENDLEY ESTATE LOT
LOT SIZE 9046SF
A LOT COVERAGEi1684/9046=18,67
ti ti SITE COVERAGEs2111/9046=23,37
I / 4' WALK
MAX SLOPE 2% I-
A
813 :� •
GP
U p UGP UGP-UG
- ••
D
PENDLEY COUPT
V-4
+
'41
if
sio
if I I I
J1
Llro f?�,
49X-7r�
4- j
I
7
i-H
E:l
--t--�—j—.._.L.—T—I—�---
_
-t--__�L -I � •---} ice! 7y�1t { t--�-;---�-
`
__`"_.-t----- -I_:--t-�• i _ � l--f—� 1—IL—I[ _ � � ! I � t 1 ! 1 i I I �—i_
!
I Cod,
-77
�_ —�—
it
__�— I i �L�I'>I J������ i �! � �'iia✓ I i ! I I ! I I L � i�; .�.—I—
T t ---
---:, -�
10 I
--.- __ i 1 ..�.;,,._,,_tt�y—.�-•—`____I--;--ice'..—:_—.-E—_�.—�___��--.—.!...�.—;+{_—i—f�� i ! I i !-4.__1.—!---}---I----I----'--
_- - -�1
i
i \M-
!;AIA
q 7f--
r-lTV-
X,,, IT
it
10
1-7
OFT
,/3, -7 1 Ll-
I
6-t!Mr,
cl
-t-4
IL
Yo�-i
.............
fit
-Jr
,A I
§r5 Z,/-
It
if I—
if
Fall
; 1 � l till !
7F
F1
r-
u t � 1
---r--- —r—'--�—r----=—t--l— —t---t—.`—'-'fir--}.-�?---1-- - ' I —�—�--L.-�
` I
i or
it
I
�._i-�--�3--�' F i _ I r 3 _ t� 1 +t G.C..✓ • t j L" �( ' �-1 ...... —
-7 -01,
- -- -
t _( _� , •_- i�-'L-_._��:-i -t __-�-_..._.i_.-,...--...( E- t ±-i� I � � � --i-1-t--.�-L ,
,�-
.—�._�
+
1
j +
r—
�___-___' —+—_._ _ - .�--—_-_...--r. .—_ �_—_ __. - - —._! _ .—_� -_ --•----_—, --_ — �, a }—T .—
MECAWind Version 2 . 1 . 0 . 5 per ASCE 7-05
Developed by MECA Enterprises, Inc. Copyright 2012 www.mecaenterprises.com
Date 10/15/2012 Project No. 12176
Company Name ZENOVIC & ASSOCIATES, INC. Designed By SRH
Address 301 EAST 6TH STREET, SUITE 1 Description 28x40 SFR
City PORT ANGELES Customer Name PENINSULA HOUSING AUTHORITY
State WA Proj Location CLALLAM COUNTY, WA
File Location: X:\12176 HOUSING AUTHORITY\ENGR\Structual\SFR DESIGN B.wnd
Detailed Wind Load Design (Method 2) per ASCE 7-05
Basic Wind Speed(V) = 100.00 mph Structure Type = Building
Structural Category = II Exposure Category = C
Natural Frequency = N/A Flexible Structure = No
Importance Factor = 1.00 Kd Directional Factor = 0.85
Alpha = 9.50 Zg = 900.00 ft
At = 0.11 Bt = 1.00
Am = 0.15 Bm = 0. 65
Cc = 0.20 1 = 500.00 ft
Epsilon = 0.20 Zmin = 15.00 ft
Slope of Roof = 4 : 12 Slope of Roof(Theta) = 18. 45 Deg
Ht: Mean Roof Ht = 10.34 ft Type of Roof = Gabled
RHt: Ridge Ht = 12.67 ft Eht: Eave Height = 8.00 ft
OH: Roof Overhang at Eave= .00 ft Roof Area = 1181.00 ft^
2
Bldg Length Along Ridge = 40.00 ft Bldg Width Across Ridge= 28.00 ft
Gust Factor Category I Rigid Structures - Simplified Method
Gustl: For Rigid Structures (Nat. Freq.>l Hz) use 0.85 = 0.85
Gust Factor Category II Rigid Structures - Complete Analysis
Zm: 0. 6*Ht = 15.00 ft
lzm: Cc* (33/Zm) ^0.167 = 0.23
Lzm: 1* (Zm/33) ^Epsilon = 427.06 ft
Q: (1/ (1+0.63* ( (B+Ht) /Lzm) ^0.63) ) ^0.5 = 0. 94
Gust2: 0. 925* ( (1+1.7*lzm*3.4*Q) / (1+1.7*3.4*lzm) ) = 0.89
Gust Factor Summary
Not a Flexible Structure use the Lessor of Gustl or Gust2 = 0.85
Figure 6-5 Internal Pressure Coefficients for Buildings, GCpi
GCPi : Internal Pressure Coefficient = +/-0.18
Figure 6-6 External Pressure Coefficients
Cp - Loads on Main Wind-Force Resisting Systems(Method 2)
MecaWind Pro v2 . 2 . 4 . 5 per ASCE 7-10
Developed by MECA Enterprises, Inc. Copyright www.mecaenterori- com
Date 9/18/2014 Project No. JobNo
Company Name True Designed By Engineer
Address Address Description Description
City City Customer Name Customer r,n
State State Proj Location Location ('/�✓7�(J
File Location: C:\Users\TRACY\AppData\Roaming\Mecawind\Default.wnd
Directional Procedure Simplified Diaphragm Building (Ch 27 Part 2)
Basic Wind Speed(V) = 130.00 mph
Structural Category = III Exposure Category = C
Natural Frequency = N/A Flexible Structure = No
Importance Factor = 1.00 Kd Directional Factor = 0.85
Alpha = 9.50 Zg = 900.00 ft
At = 0.11 Bt = 1.00
Am = 0.15 Bm = 0.65
Cc = 0.20 1 = 500.00 ft
Epsilon = 0.20 Zmin = 15.00 ft
Slope of Roof = 4 : 12 Slope of Roof(Theta) = 18.43 Deg
Ht: Mean Roof Ht = 10.33 ft Type of Roof = GABLED
RHt: Ridge Ht = 12.67 ft Eht: Eave Height = 8.00 ft
OH: Roof Overhang at Eave= .00 ft Overhead Type = No Overhang
Bldg Length Along Ridge = 40.00 ft Bldg Width Across Ridge= 28.00 ft
Gust Factor Calculations
Gust Factor Category I Rigid Structures - Simplified Method
Gustl: For Rigid Structures (Nat. Freq.>1 Hz) use 0.85 = 0.85
Gust Factor Category II Rigid Structures - Complete Analysis
Zm: 0.6*Ht = 15.00 ft
lzm: Cc*(33/Zm)^0.167 = 0.23
Lzm: 1*(Zm/33)^Epsilon = 427.06 ft
Q: (1/(1+0.63*((B+Ht)/Lzm)^0.63))^0.5 = 0.94
Gust2: 0.925*((1+1.7*lzm*3.4*Q)/(1+1.7*3.4*lzm)) = 0.89
Gust Factor Summary
Not a Flexible Structure use the Lessor of Gustl or Gust2 = 0.85
Table 26.11-1 Internal Pressure Coefficients for Buildings, GCpi
GCPi Internal Pressure Coefficient = +/-0.18
Topographic Adjustment
0.33*z = 1.00
Kzt (0.33*z) : Topographic factor at elevation 0.33*z = 1.00
Vtopo: Adjust V per Para 27.5.2: V * [Kzt(0.33*z)]^0.5 = 130.00 mph
MWFRS Diaphragm Building Wind Pressures per Ch 27 Pt 2
All pressures shown are based upon ASD Design, with a Load Factor of
MWFRS Pressures for Wind Normal to 40 ft wall (Normal to Ridge)
WALL PRESSURES PER TABLE 27.6-1
L/B: Bldg Dim in Wind Dir / Bldg Dim Normal to Wind Dir = 0.70
h: Height to top of Windward Wall = 8.00 ft
ph: Net Pressure at top of wall (windward + leeward) = 21.18 psf
p0: Net Pressure at bottom of wall (windward + leeward) = 21.18 psf
ps: Side wall pressure acting away from wall = .54 * ph = -11.44 psf
pl: Leeward wall pressure acting away from wall = .38 * ph = -8.05 psf
pwh: Windward wall press @ top acting toward wall = ph-pl = 13.13 psf
pw0: Windward wall press @ bot acting toward wall = p0-p1 = 13.13 psf
ROOF PRESSURES PER TABLE 27.6-2
h: Mean Roof Height = 10.334 ft
Lambda: Exposure Adjustment Factor = 1.000
Slope: Roof Slope = 18.43 Deg
Zone Load Casel Load Case2
psf psf
---- ---------- ----------
1 -15.99 5.54
2 -12.90 -5.70
3 -19.86 .00
4 -17.70 .00