HomeMy WebLinkAbout1433 E. 5th Street Address:
1433E 5th Street
PREPARED 6/12/14, 12:08:19 INSPECTION TICKET _PAGE 5 ,
CITY OF PORT ANGELES INSPECTOR: JAMES LIERLY DATE 6/12./14
------------------------------------------------------------------------------------------------
ADDRESS 1433 E 5TH ST SUBDIV:
CONTRACTOR : PHONE
OWNER BOYD MARY E PHONE
PARCEL 06-30-00-0-1-8185-0000-
APPL NUMBER: 13-00001024 RES REPAIR
------------------------------------------------------------------------------------------------
PERMIT: BPR 00 BUILDING PERMIT - RESIDENTIAL
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
BL6 01 9/24/13 JLL BLDG POST/COLUMN FTG
9/24/13 AP September 24, 2013 8:13:04 AM pbarthol.
Kim 461-4949
Call lst
Jn�} September 24, 2013 4:00:51 PM jlierly.
BL99 01 6/12/14 /ILL BLDG FINAL
June 11, 2014 11:12:51 AM pbarthol.
�u Kim 461-4949
Call 1/2 hr ahead so he can let you in for inspection
-------------------------------------- COMMENTS AND NOTES
CITY OF PORT ANGELES
DEPARTMENT OF COMMUNITY & ECONOMIC DEVELOPMENT- BUILDING DIVISION
321 EAST 5TH STREET, PORT ANGELES,WA 98362
Application Number . . . . . 13-00001024 Date 9/19/13 MN
Application pin number . . . 680256
AddressProperty
ASSESSOR PARCELNUMBER: 06330-00-0 -1-8185-0000- REPORT SALES TAX
Application type description RES REPAIR
Subdivision Name
on your state excise tax form
Property Use . . . . . . . . to the City of Port Angeles
Property Zoning . . . . . . . RS7 RESDNTL SINGLE FAMILY ((Location Code OSO2�
Application valuation . . . 4000
Application desc
REBUILD EXISTING DECK
----------------------------------------------------------------------------
Owner Contractor
BOYD MARY E OWNER
1433 E 5TH ST
PORT ANGELES WA 98362
----------------------—------------`---------------------------------------
Permit . . . . . . BUILDING.PERMIT -RESIDENTIAL
Additional desc . . REBUILD EXISTING DECK S
Permit Fee . . . . 123.75 Plan Check Fee 80.44
Issue Date . . . . 9/19/13 Valuation . . . . 4000 A
Expiration Date 3/18/14
Qty Unit Charge Per Extension '!
BASE FEE 95.75
2.00 - 14.0000 THOU BL-2001-25K (14 PER K) 28.00 vW
Special Notes and Comments 11
Public Works Utility Engineering has no requirements for
this plan review.
September 16, 2013 3:00:06 PM tamiot.
12ft clearance required from deck service to electrical
service conductors.
September 18, 2013 11:39:51 AM sroberds.
The project does not involve additional lot coverage. No
land use issues are anticipated.
----------------------------------------------------------------------------
Other Fees . . . . . . . STATE SURCHARGE 4.50
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
Permit Fee Total 123.75 123.75 .00 .00
Plan Check Total 80.44 80.44 .00 .00
Other Fee Total 4.50 4.50 .00 .00
Grand Total 208.69 208.69 .'00 .00
Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes
null and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned
for a period of 180 days after the work has commenced,or if required:inspections have not been-requested within 180 days from the
last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions
of laws and ordinances governing this type of work will be complied with whether specified herein or.not. The granting of a permit does
not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construction.
Y�J
Date Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder)
T:Forms/Building Division/Building Permit
BUILDING PERMIT INSPECTION RECORD
PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS—
Building Inspections 417-4815 Electrical Inspections 417-4735
Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886
IT IS UNLAWFUL.TO COVER,INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED.
POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE.
Inspection Type Date Accepted By Comments
FOUNDATION:
Footings
Stemwall
Foundation Drainage/Downspouts
Piers
Post Holes(Pole Bldgs.)
PLUMBING:
Under Floor/Slab
Rough-in
Water Line(Meter to Bldg)
Gas Line
Back Flow/Water FINAL Date Accepted b
AIR SEAL:
Walls
Ceiling
FRAMING:
Joists/Girders/Under Floor
Shear Wall/Hold Downs
Walls/Roof/Ceiling
Drywall Interior Braced Panel Only)_
T-Bar
INSULATION:
Slab
Wall/Floor/Ceiling
MECHANICAL:
Heat Pum /Furnace/FAU/Ducts
Rough-in
Gas Line
Wood Stove/Pellet/Chimney
Commercial Hood/Ducts FINAL Date Accepted b
MANUFACTURED HOMES:
Footing/Slab
Blocking&Hold Downs
Skirting
PLANNING DEPT. Separate Permit#s SEPA:
Parkin /Lighting ESA:
Landscaping SHORELINE:
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE
Inspection Type Date Accepted By
Electrical 417-4735
Construction-R.W. PW /Engineering 417-4831
Fire 417-4653
Planning 417-4750
Building 417-4815
T:Forms/Building Division/Building Permit
IT O ' ° For City Use
CITo�
ANGELES
Permit#
4 N
w A s H i N G T , U . s . Date Received:
321 E 51h Street ate Approved 9112 h 1Z
Port Angeles,WA 9836
P:360-417-4817 F: 360-417-4711
Email:permitsC@cityofpa.us BUILDING PERMIT- A PLICATION
Project Address: 711 6'1
Phone: ?6d
PrimaryContact: U��� y Email:
Name �/,L'l Phone
Property Mailing Address nD` .-}f l Email i, Y�
Owner j� OX pC(r� L"Ve11 h 6 Ol '-tno mom
City . State 41'.'4,el fee-� �7
Name Phone
(O
Contractor Address Email
Information City State Zip
Contractor License# Exp.Date:
Legal Description: Zoning: Tax Parcel # Project Value: (materials and labor)
Residential Commercial ❑ Industrial ❑ Public ❑
Permit Demolition ❑ Fire ❑ Repair Reroof(tear off/lay over) ❑
Classification For the following fill out both pages of permit application:
(check New Construction ❑ Exterior Remodel ❑ Addition ❑ Tenant Improvement ❑
appropriate) Mechanical ❑ Plumbing ❑ Other ❑
Will a fire sprinkler system be installed Irrigation System? Proposed Bathrooms Proposed Bedrooms
or modified? Yes ❑ No ' Yes ❑ No
Project Description ' !je{v/b tfe
Is project in a Flood Zone: Yes ❑ Nolg/ Flood Zone Type:
If in a Flood Zone, what is the value of the structure before proposed improvement? $
I have read and completed the application and know it to be true and correct. I am authorized to apply for
this permit and understand that it is my responsibility to determine what permits are required and to
obtain permits prior to work. I understand that plan review fees are not refundable after review has
occurred. I understand that I will forfeit review fees if I withdraw the application before the permit is
issued. I understand that if the permit is not picked up/issued within 18o days of submittal,the application
will be considered abandoned and the fees will be forfeited.
q11011-5 M. aft
r� .
Date Print Name Signature
Residential Structures
For Office Use
Area Description(SQ FT) Existing Proposed $$value
Basement
First Floor
Second Floor
Covered Deck/Porch/Entry
Deck(over 30"or i" floor)
Garage
Carport ,
Other(describe)
Area Totals
Commercial Structures
Proposed For Office Use
Area Descriptions(SQ FT) Existing Proposed ss Value
Existing Structure (s)
Proposed Addition
Tenant Improvement?
Other work(describe)
Site Area Totals
f'
Lot/Site Coverage Calculations
Lot Size (sq ft) Lot Coverage (sq ft) %Lot Coverage (Total lot coverage_lot size)
Site Coverage (Sq Ft of all impervious) %of Site Coverage (total site coverage-lot size)
Mechanical Fixtures
Indicate how many of each type of fixture to be installed or relocated as part of this project.
Air Handler Size: # Haz/Non-Haz Piping Outlets:
Appliance Exhaust Fan # Heater(Suspended,Floor, Recessed wall) #
Boiler/Compressor Size: # Heating/Cooling appliance #
repair/alteration
Evaporative Cooler(attached,not # Pellet Stove/Wood-burning/Gas #
portable) Fireplace/Gas Stove/Gas Cook Stove/Misc.
Fuel Gas Piping #of Outlets: Ventilation Fan,single duct #
Furnace/Heat Pump/ Size: # Ventilation System #
Forced Air Unit
Plumbing Fixtures
Indicate how many of each type of fixture to be installed or relocated
Plumbing Traps # Fuel gas piping #of Outlets:
Water Heater # Medical gas piping #of Outlets:
Water Line # Plumbing Vent piping #
Sewer Line # Industrial waste pretreatment
interceptor Grease Trap) Size
Other(describe):
T:\BUILDING\APPLICATION FORMS\Current BP Application\Building Permit 4-17-13.docx
s
g , r
'rry
P '.
y �
0*1
rq
Y 9
t
�br
a
F
k
I
C�TJ-
z <
0m
zSEE SEC. 1003.3.3.6 0�
rm co FOR HANDRAIL REQ.
O ALSO SEE HANDRAIL DETAIL
O
Q
zs
o _
o
--4 yo P� - O
g�QJ\R�O STAIR STRINGERS ARE �u
O i REQUIRED TO BE SUPPORTED —I
AT TOP OR USE APPROVED
METAL HANGARS.) D
r z
PARALLEL FIRE BLOCKING D
0
D �� D r
4"MIN. RISE
' cn
_ 7 3/4" MAX. RISE //' _- 11" MIN.
D D
�' fTl -p
�U � �'/ D UJ
�I r
_ � n
3X3'LANDING REQUIRED. • SECURE A T LANDING
z OCCUPANT LOAD OF 10 OR MORE �
N07ES NOT TO EXTEND MORE
THAN 3 1/2"INTO REQ. U)
1. MAXIMUM CONSTRUCTION VARIANCE PERMITTED : iQ
STAIR WIDTH.
3/8" FOR TREAD RUN.
3/8" FOR RISER HEIGHT. 1 1/2" M/N. m
-' 2. HANDRAILS SHALL BE CON77N000S THE FULL LENGTH OF
THE STAIRS AND EXCEPT FOR PRI VA TF STAIRWA YS. A T
LEAST ONE HANDRAIL SHALL EXTEND IN 77AE DIREC77ON OF 1 1/4
--{ THE STAIR RUN NOT LESS 77-IAN 12" BEYOND 7N " - 2'"DIA.
E TOP HANDRAILRISER OR LESS THAN 12" BEYOND THE BOTTOM RISER. ENDS
SHALL BE RE7URNED OR SHALL 7ERMINATE IN NEWELL
POSTS OR SAFETY 7ERMINALS
---- HANDRAIL D-7-AIL
C) D
G7 FTI
Z 0 n C
Fri cu
O
Frityl
.. j M/D SPAN BLOCK/NG MINIMUM 2" x 4" CAP �
WHEN FL OOR�JOIST GUARDRAIL W/)N7ERMEDIA TFS L OCA TED SO TNA T A
EXCEED 12' 4" SPHERE CANNOT PASS THROUGH
GUARDRAIL HEIGHTS-
COMMERCIAL 42" MIN.
PRO14DE FLASHING PER CODE RESIDENTIAL 36" MIN.
AiA
C7
F9
i DECK/NG MATERIAL - 4'x4 ® - �► ' OR MFC.
G. SPE
FLOOR JOIST (2) 7/16" BOL TS W/ WASHERS O
SECURING POSTS.
O
Z) JOIST HANGER o
T
c� LA 7FRAL RESISTANCE
�= SAME AS POST SIZE NOTES Cf) D
MA 7ERIAL HEADER --I-I z
/k — I. USE HOT DIP ZINC GALVANIZED D
W LEDGER a X!�. FASTENERS IN TREA TED 'WOOD (SEE z m
j WI7H 3/8"x5" POST CAP OR T-S77?AP MFG SPECIFICA77ONS) FOR TREATED [-
LAG BOLTS ® 16" 0.C. WOOD APPLICA TONS D Frl
STAGGERED. � C!)
2. SEE PAGE 3 FOR �
POST, MlN/MUM 4'X4" F9077NGIHEADER/FLOOR JOIST
SPANS �
(SEE PAGE 3)
FLOOR JOIST SPAN 3. SEE PAGE 4 FOR STA/R111YANDRAIL mC
"X ® feet O C DETAILS. D
co
4. WOOD TO BE DECAY RES/STAN T r r
7
1 SEPARA TION
OR TREATED PER 2003 IRC R319. CIOC)5 DECKS SHALL"
2003 /RC. SEE A MEET R 502.2.1 OF
TTA CHED.
w 12"" M/N.
6. ANY SPA OR HOT TUB LOCATED
CONCRETE FOOLING _:; • :� ON DECK SHALL BE ENGINEERED FOR
n LOAD AND LATERAL DESIGN. (f)
O
fr1
-0
WASHINGTON STATE AMENDMENTS
R507.2.2 Alternate deck ledger connections. Deck ledger
connections not conforming to Table R507.2 shall be
attached with approved fasteners having equivalent
withdrawal capacity or be designed in accordance with
accepted engineering practice. Girders supporting deck
joists shall not be supported on deck ledgers or band joists.
Deck ledgers shall not be supported on stone or masonry
veneer.
R507.2.3 Deck lateral load connections. The lateral load
connection required by Section R507.1 shall be permitted to
be in accordance with Figure R507.2.3. Where the lateral
load connection is provided in accordance with Figure
R507.2.3(1),hold-down tension devices shall be installed in
not less than two locations per deck,and each device shall
have an allowable stress design capacity of not less than
1500 pounds(6672 N).
Exceptions:
1. Decks not more than 30 inches above grade at any
point may be unattached.
2. Where a new deck is being added to an existing
structure,the lateral load connection required by
Section R507.1 shall be permitted to be in
accordance with Figure R507.2.3(2).
Siding
Sheathing
Note: Flashing for
This detail is applicable where
floorjoists are parallel to deck water tightness
joists.
�-Decking
Deck joists Table R502.3.1(2)
Approved joist hangers
2"min. Pressure treated 2x ledger with
fasteners per IRC Table R507.2
—y Holdown device min 750#capacity
\ at 4 locations,evenly distributed
Floor joists \� along deck&1 within 2'of each
end of the ledger.Holdown devices
shall fully engage deck joist.
A fully threaded 3/8"diameter lag
screw predrilled w/min 3"penetration
to top plate,studs,or header.
Figure R507.2.3(2)
(Insert Facing Page 146)
Effective July 1, 2013
6 Alrt-t�f � 70
f 44 ,
N 3 1�
O c o n y
Mod
w
♦� Cp m
d
L. A
r
/O6
,,p,c
n
O `_' c L m co