HomeMy WebLinkAbout201 W 1st Street Address:
201 W Is' Street
PREPARED 5/08/17, 9:14:07 INSPECTION TICKET PAGE 4
CITY OF PORT ANGELES INSPECTOR: JAMES LIERLY DATE 5/08/17
------------------------------------------------------------------------------------------------
ADDRESS . : 201 W 1ST ST SUBDIV:
CONTRACTOR SCHMITT'S SHEET METAL INC. PHONE (360) 457-6452
OWNER TINE CONSTRUCTION SERVICE LLC PHONE
PARCEL 06-30-00-0-0-1480-0000-
APPL NUMBER: 16-00001882 COMM MECHANICAL PERMIT
------------------------------------------------------------------------------------------------
PERMIT: ME 00 MECILANICAL PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
ME99 01 5/08/17 MECHANICAL FINAL
o May 8, 2017 9:07:36 AM jlierly.
Dean 457-6452/460-7970
-------------------- ---- --------- COMMENTS AND NOTES --------------------------------------
CFYY OF PORT ANGELES
DEPARTMENT OF COMMUNITY& ECONOMIC DEVELOPMENT- BUILDING DIVISION
321 EAST 5TH STREET, PORT ANGELES, WA 98362
Application Number . . . . . 16-00001882 Date 12/23/16
Application pin number . . . 003338
Property Address . . . . . . 201 W IST ST. REPORT SALES TAX
ASSESSOR PARCEL NUMBER: 06-30-00-0-0-1480-0000- on your state excise tax form
Application type description COMM MECHANICAL PERMIT
Subdivision Name . . . . . . to the City of Port Angeles
Property Use .. . . . . . . . (Location Code 0502)
Property zoning .. . . . . . . CENTRAL BUSINESS DISTRICT
Application valuation . . . . 87000
----------------------------------------------------------------------------
Application desc
Install 11 rooftop HVAC Units
----------------------------------------------------------------------------
Owner Contractor
------------------------ ------------------------
TINE CONSTRUCTION SERVICE LLC SCHMITT'S SHEET METAL INC.
PMB 507 3341 E. HIGHWAY 101
SAMMAMISH WA 980757253 PORT ANGELES WA 98362
(360) 457-6452
---------------------------------------------------------------------
Permit . . .. . . . MECHANICAL PERMIT
Additional desc . . INSTALL 11 ROOFTOP HVAC UNITS
Permit Fee . . . . 212.80 Plan Check Fee .00
Issue Date . . . . 12/23/16 . valuation . . . . 0
Expiration Date 6/21/17
Qty Unit Charge Per Extension
BASE FEE 50.00
11.00 14.8000 EA ME-FURN/HP/FAU < OR 5 TON 162.80
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ----------- -----------
Permit Fee Total 212.80 212.80 .00 .00
Plan Check Total .00 .00 .00 .00
Grand Total 212.80 212.80 .00 .00
Separate Permits are required forelectrical work,SEPA,Shoreline,ESA,utilities,private and'public improvements. This permit becomes
null and void if work or construction authorized is not commenced within.180 days,if construction or work is suspended or abandoned
for a period of 180 days after the work has commenced, or if required inspections have not been requested within 180 days from the
last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions
of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does
not presume to gi.ve authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construction.
Z-Z_�- 6 , ��&/ 12
Date Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder)
T:Forms/Building Division/Building Permit
BUILDING PERMIT INSPECTION RECORD
PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS—
Building Inspections 417-4815 Electrical Inspections 417-4735
Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886
IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED.
POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE.
Inspect ion Type Date Accepted By Comments
FOUNDATION:
Tootings
Stemwall
Foundation Drainage/Downspouts
Piers
Post Holes(Pole Bldgs.)
PLUMBING:
Under Floor/Slab
Rough-in
Water Line(Meter to Bldg)
Gas Line
Back Flow/Water
AIR SEAL:
Walls
Ceiling
FRAMING:
Joists/Girders/Under Floor
Shear Wall/Hold Downs
Walls/Roof/Ceiling
5i��all(Interior Braced Panel Only)
T-Bar
INSULATION:
Slab
Wall/Floor/Ceili ng
MECHANICAL:
Heat Pump/Furnace FAU Ducts
Rough-in
Gas Line
Wood Stove/Pellet Chimney
Commercial Hood/Ducts
MANUFACTURED HOMES:
Footing/Slab
113locking&Hold Downs
ISkirting
PLANNING DEPT. Separate Permit#s SEPA:
Parking/Lighti ESA:
Landscaping jSHORELINE:
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY1 USE
Inspection Type Date Accepted By
Electrical 417-4735
Construction-R.W. PW I Engineering 417-4831
Fire 41.7-4653
Planning 417-4750
Building 417-4815
For City Use
THE:
CITY OF
Permit#
W Date Received: k /Z 3t(6
321 E 5th St Date Approved k 2--3Z 6
Port Angell
P:360-417-4817 F:360-417-4711
Email:permitsOciWoflia.us BUILDING PERMIT APPLICATION
Project Address: 201 W Is' Street
360 457-6452
Primary Contact:Dean Schmitt dschmittoolypen.com
Tine Construction Services LLC 425 417-8800
Property Email
-PO Box 1235 tcsesd@gmail.com
Owner city StateWA 98o38
Maple Valley
Name Phone
Schmitt's Sheet Metal,Inc 36o 457-6452
Address Email
Contractor 32 Prospect Place dschmitt@olypen.com
Information city State Zip
Port Angeles Wa 9836z
Contractor License#SCHMISMIL02Kl Exp.Date:4-4-2oi8
r
Legal Description: Zoning: Tax Parcel# Project Value: (materials and labor)
$ 23 �h , 00
Residential Commercial X2] Industriai 0 Public [:1
Permit Demolition 1:1 Fire 1:1 Repair El Reroof(tear off/lay over) El
Classification For the following,fill out both pages of permit application:
(check New Constru Exterior Remodel F� Addition F I Tenant Improvement F-1
appropriate) I Mechanical 92mbing F1 Other
Will a fire sprinkler system be ins4lled Irrigation System? Proposed Bathrooms Proposed Bedrooms
or modified? Yes El No XEI Yes E] No XE]
Project Description
Replace existing rooftop IHVAC�
units with new. See attached
spreadsheet for electrical changes.
Is project in a Flood Zone: Yes F� NoxF-1 Flood Zone Type:
If in a Flood Zone, what is the value of the structure before proposed improvement? $
I have read and completed the application and know it to be true and correct. I am authorized to apply for
this permit and understand that it is my responsibility to determine what permits are required and to
obtain permits prior to work. I understand that plan review fees are not refundable after review has
occurred. I understand that I will forfeit review fees if I withdraw the application before the permit is
issued. I understand that if the permit is not picked up/issued within 18o days of submittal,the application
will be considered abandoned and the fees will be forfeited.
Date Print Name Signature
Residential Structures
For Office Use
Area Description(SQ FT) Existing Proposed ss value
Basement
First Floor
Second Floor
Covered Deck/Porch/Entry
Deck(over 30"or 2nd floor)
Garage
Carport
Other(describe)
Area Totals
Commercial Structures
Proposed For Office Use
Area Descriptions(SQ FT) Existing Proposed ss Value
Existing Structure (s) 28000
Proposed Addition 0
Tenant Improvement? 0
Other work(describe) 0
Site Area Totals 0
Lot/Site Co erage Calculations
Lot Size (sq ft) TFOt Coverage (sq ft) %Lot Coverage (Total lot coverage lot size)
Site Coverage(Sq Ft of all impervious) %of Site Coverage (total site coverage--. lot size)
Mechanical Fixtures
Indicate how many of each type of fixture to be installed or relocated as part of this project.
Air Handler: Size: # Haz/Non-Haz Piping: Outlets:
12 unit see attachment
Appliance Exhaust Fan: # Heater(Suspended,Floor,Recessed wall): #
Boiler/Compressor Size: # Heating/Cooling appliance #
I repair/alteration
Evaporative Cooler(attached,not # Pellet Stove/Wood-burning/Gas #
portable): Fireplace/Gas Stove/Gas Cook Stove/Misc.
Fuel Gas Piping: #of Outlets: Ventilation Fan,single duct: #
Furnace/Heat Pump/ Size: # Ventilation System: #
ForcedAir Unit: I I
Plumbing Fixtures
Indicate how many of each type of fixture to be installed or relocated
Plumbing Traps # Fuel gas piping #of Outlets:
Water Heater # Medical gas piping #of Outlets:
Water Line # Plumbing Vent piping #
Sewer Line # Industrial waste pretreatment
interceptor(Grease Trap) Size
Other(describe):
T:\BUILDING\APPLICATION FORMS\Current BP Application\Building Permit 4-17-13.docx
DES MODEL Nom Cap CFM Min OSA ESP Aux heat Circuit MCA MOCP Current Service Current Fuses
RTU-1 50KCQA06A2A5-2UOAO 5 2000 367 0.8 7.9 60 58 60 3#6#10 GND 60
RTU-2 50TCQA07A3A5-2UOAO 6 2400 380 0.8 7.9 70 63 70 3#4#8 GND 70
RTU-4 50KCQA06A2A5-2UOAO 5 2000 300 0.8 7.9 60 59 60 3#4#8 GND 70
RTU-5 50KCQA05A2A5-2UOAO 4 1600 300 1 7.9 60 49 50 Install 50 A fuses 3#6#10 GND 60
RTU-6 retained 10 4000 800 1 7.8 90 3#1#6 GND 90
RTU-7 50KCQA06A2A5-2UOAO 5 2000 500 0.8 7.9 60 58 60 3#6#10 GND 60
RTU-8 50KCQA06A2A5-2UOAO 5 2000 650 0.8 7.9 60 58 60 3#6#10 GND 60
RTU-12 50KCQA04A2A5-2UOAO 3 1200 250 0.6 7.9 60 47 50 Install 50 A fuses 3#6#10 GND 60
RTU-10 50KCQA06A2A5-2UOAO 5 2000 630 0.8 7.9 60 58 60 3#6#10 GND 60
RTU-11 50KCQA05A2A5-2UOAO 4 1600 400 0.8 6.5 60 47 50 Install 50 A fuses 3#6#10 GND 60
RTU-9 50KCQA06A2A5-2UOAO 5 2000 205 0.6 7.9 60 58 60 3#6#10 GND 60
RTU-13 50KCQA07A3A5-2UOAO 6 2400 280 0.8 7.9 70 63 70 3#4#8 GND 70