HomeMy WebLinkAbout2140 W. 18th Street Address:
2140 18 Ih Street Bldg-1010
PREPARED 6/25/15, 10:15:S7 INSPECTION TICKET PAGE 2
CITY OF PORT ANGELES INSPECTOR: JAMES LIERLY DATE 6/25/15
------------------------------------------------------------------------------------------------
ADDRESS . : 2140 BLDG 1010 W 18TH ST SUBDIV:
CONTRACTOR CRESCENT MECHANICAL PHONE (253) 833-SO54
OWNER PORT OF PORT ANGELES PHONE (360) 457-8527
PARCEL 06-30-00-1-1-2100-5001-
APPL NUMBER: 15-00000185 COMM MECHANICAL PERMIT
------------------------------------------------------------------------------------------------
PERMIT: ME 00 MECRANICAL PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
ME1 01 6/09/15 JLL MECHANICAL ROUGH-IN
6/09/15 AP June 9, 2015 9:25:44 AM jlierly.
james 253-606-7211
June 9, 2015 4:50:39 PM jlierly.
ME99 01 6/ /15 JLL MECHANICAL FINAL
June 25, 2015 10:17:08 AM pbarthol.
s 253-606-7211
------- ......... .... COMMENTS AND NOTES --------------------------------------
CITY OF PORT ANGELES
DEPARTMENT OF COMMUNITY & ECONOMIC DEVELOPMENT- BUILDING DIVISION
321 EAST 5TH STREET, PORT ANGELES,WA 98362
Application pin number
Application Number . . . . . 15-00000185 Date 5/04/15
. . . 353185
Property Address . . . . . . 2140 BLDG 1010 W 18TH ST
ASSESSOR PARCEL NUMBER: 06-30-00-1-1-2100-5001- REPORT SALES TAX
Application type description COMM MECHANICAL PERMIT
Subdivision Name . . . . . . on your state excise tax form
Property Use . . I . . . . . to the City of Port Angeles
Property Zoning . . . . . . . INDUSTRIAL LIGHT
Application valuation . . . . 55000 (Location Code 0502)
----------------------------------------------------------------------------
Application desc
upgrade to HVAC system, 20 VAV BOXES, AHU
----------------------------------------------------------------------------
Owner Contractor
------------------------ ------------------------
PORT OF PORT ANGELES CRESCENT MECHANICAL
PO BOX
1350 1320 26TH ST NW #16
PORT ANGELES WA 983620251 AUBURN WA 98001
(360) 457-8527 (253) 833-5054
-----------------------------------------------------------------------------
Permit . . . . . . MECHANICAL PERMIT
Additional desc . . HVAC UPGRADE
Permit Fee . . . . 313.80 Plan Check Fee .00
Issue Date . . . . 5/04/15 Valuation . . . . 0
Expiration Date . . 10/31/lS.
Qty Unit Charge Per Extension
BASE FEE 50.00 Q)
1.00 18.1000 EA ME-AIR HAND >10,000 CFM 18.10
2.00 7.2500 EA ME-VENT FAN (SINGLE DUCT) 14.50
20.00 10.6500 EA ME-VENT SYSTEM 213.00
1.00 18,2000 EA ME-FURN/HP/FAU > 5 TON 18.20
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 313.80 313.80 .00 .00
Plan Check Total .00 .00 .00 .00
Grand Total 313.80 313.80 .00 .00
Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes
null and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned
for a period of 180 days after the work has commenced, or if required inspections have not been requested within 180 days from the
last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions
of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does
not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construction.
q
1;4eo
Date Print Name Signature of Con Vactor or Authorized Agent Signature of Owner(if owner is builder)
T:Forms/Building Division/Building Permit
BUILDING PERMIT INSPECTION RECORD
— PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS—
Building Inspections 417-4815 Electrical Inspections 417-4735
Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886
IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED.
POST PERMITIN CONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE.
Inspection Type Date Accepted By Comments
FOUNDATION:
Footings
Sternwall
Foundation Drainage/Downspouts
Piers
Post Holes(Pole BIdgs.)
PLUMBING:
Under Floor/Slab
Rough-in
Water Line(Meter to Bldg)
Gas Line
.Back Flow/Water FINAL Date Accepted by
AIR SEAL:
Walls
Ceiling
FRAMING:
Joists/Girders/Under Floor
Shear Wall/Hold Downs
Walls/Roof/Ceiling
Drywall(interior Braced Panel Only)
T-Bar
INSULATION:
Slab
Wall/Floor/Ceiling
MECHANICAL:
Heat Pump/Furnace/FAU/Ducts
Rough-In
Gas Line
Wood Stove/Pellet/Chimney
Commercial Hood/Ducts FINAL Date Accepted by
MANUFACTURED HOMES:
Footing/Slab
Blocking&Hold Downs
Skirting
PLANNING DEPT. Separate Permit#s SEPA.
Parking/Lighting ELSA:
S ,
Landscaping SHORELINE:
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY1 USE
Inspection Type Date Accepted By
Electrical 417-4735
Construction- R.W. PW I Engineering 417-4831
Fire 417-4653
Planning 417-4750
L Building 417-4815
T:Forms/Building Division/Building Permit
THE: For City Use
CITY F
-)ermit#
0 NSt G5-i"-;,-E,Li;E"'
W A S H 1 0 N, U . S. Date Received:
3 2 1 E Sth Street D e Approved -!:2/.,2!?
Port Angeles,WA 9836
P:360-417-4817 F: 360-417-4711
Email:permits C@cityofp a.us BUILDING PERM11 P/LICATION
1440 l'i to"'� f�m-'OL,4b itko
Project Address: '-'4��-
Guy Hamilton Phone: 253 833-5054
Primary Contact: Email: guy@crescentsheetmetal.com
Name Port of Port Angeles/ Chris Hartman Phone 360 417-3422
Property MailingAddress 338Wlstst. Email
Owner
city Port Angeles State WA z'P 98362
Name Crescent Mechanical Phone 253 833-5054
Contractor Address 1320 26th St. NW#16 Email
Information city Auburn State WA ziP 98001
Econtractors License# CRESCSM003KN Exp.Date: 0522/2015
Legal Description: Zoning: Tax Parcel# Piroject Value: $55,000.00
1,/ $
Residential 11 Commercial E!F' Industrial El Public 11
Permit Demolition 0 Fire 11 Repair 11 Reroof(ted r off/lay over)
Classification For the following,fill out both pages of permit application:
(check New Constru41pn 11 Exterior Remodel 11 Addition 11 Tenant Improvement
appropriate) , Mechanical &PTlumbing 11 Other El
Fire Sprinkler Sf/em? Irrigation Syj�? Proposed Bathrooms Proposed Bedrooms
Yes 0 No Yes 0 No - NA- J - NA-
Project Description _HVAC Upgrade to the building on 4940-T8T179t. Installing new AHU, Exhaust Fan and
VAV Boxes.
-Z 0 ef 0 1(Z
Is project in a Flood Zone: Yes 0 Nok--Flood Zone Type: NA-
If in a Flood Zone, what is the value of the structure before proposed improvement? $
I have read and completed the application and know it to be true and correct. I am authorized to apply for
this permit and understand that it is my responsibility to determine what permits are required and to
obtain permits prior to work. I understand that plan review fees are not refundable after review has
occurred. I understand that I will forfeit review fees if I withdraw the application before the permit is
issued. I understand that if the permit is not picked up/issued within 18o days of submittal,the application
will be considered abandoned and the fees will be forfeited.
02/16/2015 Nancy Hamilton
Date Print Name Signature
A
Residential Structures
�7�a Description(SQ FT) Existing Proposed ss value For Office Use
Basement
First Floor
Second Floor
Covered Deck/Porch/Entry
"d
Deck(over 30"or 2 floor)
Garage
Carport
Other(describe)
Area Totals
Commercial Structures
For Office Use
a Descriptions(SQ FT) Existing Proposed ss Value
Existing Struct3l-'*�
Proposed Addition
Tenant Improvement?
Other work(describe)
Site Area Totals
Lot/Site Co erage Calculations
Lot Size (sq ft) Lot Coverage(sq ft) %Lot Coverage(Total lot coverage-
Site Coverage(Sq Ft of all impervious) %of Site Coverage(total site coverage lot size)
Mechanical Fixtures
Indicate how many of each type of fixture to be installed or relocated as part of this project.
.-, Haz/N
Air Handler,-O--------- Size:- bn�Haz-Piping Outlets:-
Appliance Exhaust Fan # Heater(Suspended,Floor,Recessed wall) #
Boiler/Compressor Size: # Heating/Cooling appliance #
repair/alteration
Evaporative Cooler(attached',not # Pellet Stove/Wood-burning/Gas #
portable) Fireplace/Gas Stove/Gas Cook Stove/Misc.
Fuel Gas Piping #of Outlets: Ventilation Fan,single duct #
Furnace/Heat Pump/ Size: # Ventilation System VAV Boxes # 20
Forced Air Unit I I
�1� Plumbing Fixtures
Indicate 49R�l �of each type of fixture to be installed or relocated
Plumbing Traps # Fuel gas piping #of Outlets:
Water Heater Medical gas piping #of Outlets:
Water Line # �ent piping #
Sewer Line # Industrial waste prerrVMM44L,,.
interceptor(Grease Trap)
Other(describe):
T:\BU1LD1NG\APPL1r-AT10N FORMS\Current 13P Application\Building Permit 4-17-13.docx
To: City of Port Angeles
Building Department
321 E 5 Ih St
Port Angeles, WA 98362
February 20, 2015
From: Nancy Hamilton
Re: Port of Port Angeles 10 10 Building 14VAC Upgrade Project
Please see attached two copies of the drawings and permit application for the
above address. If you have any questions you can contact my-self or Guy
Hamilton and/or cost of permit.
You can contact me at nancy@crescentsheetmetal.com or
guyQcrescentsheetmetal.com
Thank you, I
Nancy Hami�lto
1320 26" St. NW#16 Auburn,WA 98001! 253 833-5054/Fax: 253 833-5144
211 9116 in Channel O.D.
- ------ ----- ------
1 45 1/8 in
< <
Z
90 1/4 in
Chan I C.D.
F- 1 1/2 in
LLJ D
c)
45 1/8 in
A It
-—-— -—-— —-—- -JA
Prime GaW Steel 14 Ga.
------ ----- ------11 1------
---- -------------------IL
71 5/16 in—176 11/16 in Plan
36 in
6 in 4 o 72 in 59 9/16 in 72 in-------1 �-4 in Insulation Plenum Liner 1 1/2 in
HE ------- - ---- ----- ------
It I-,
T--; ii i H
24 in i i i ii
I I R/A S/A
i it ii i 11 1
Floor Pan
6 in 2 in-�
SECTION B-B
106 15116 in 104 5/8 in
SECTION A-A
Send 55 ft.of 1/4 x 1 1/2 Gasketing/Curb Thybar Corporation hyCurb
Qty:1 1 Job# I Tag: El
TC-3 Plenum Horizontal Roof Curb Dwg. By:Tyler Warner IDate:9/21/2012
McQuay MPS040/05OF(Slab Mounted)
Sheet of C�ffi�%RC13WI-RC137�RC13593IRClW93.i� M 1 of 5
159302.4
D D HEATING
D VENTILATING AND
AIR CONDITIONING
COMPOffy EQUIPMENT
3805 108TH AVE NE Suite 210 BELLEVUE,WA 98004
PHONE 425-828-6636—FAX 425-828-3982 EMAIL: sales(dnorbvco.com
1010 BUILDING
PORT ANGELES, WA
SUBMITTAL DATA FOR
ENVIRO-TEC
FAN POWERED VAV BOX
SPEC SECTION 15930
CFR-EH/CFRQ-EH
TAGS: VARIOUS
ENGINEER:
RICE GROUP
LYNNWOOD,WA
SOLD TO:
CRESCENT MECHANICAL
AUBURN,WA
1/28/2015
PROVIDED BY: NOR-BY COMPANY
BELLEVUE,WA
1010 BUILDING
PORT ANGELES,WA
01/28/2015
ENVIRO-TEC VAV TERMINALS - MODEL CFR/()-E
SERIES TYPE FAN
GENERAL NOTES:
FAN POWERED VARIABLE VOLUME TERMINAL FURNISHED WITH
FOIL LINED FACTORY INSULATION, 277v/lph ECM MOTOR,ELECTRIC
HEAT COIL.) MAGNETIC CONTACTOR,FAN RELAY,24 VOLT CONTROL
TRANSFORMER, NON-FUSED DOOR INTERLOCKING DISCONNECT,
SHEETMETAL CONTROL ENCLOSURE FOR FACTORY INSTALLED DDC
CONTROLS (CONTROLS FURNISHED BY OTHERS.)ENTIRE UNIT IS ETL
LISTED.
FURNISHED BY OTHERS IN THIS CONTRACT:
DDC CONTROLS,LABOR WARRANTY.
1010 BUILDING VAV TERMINAL UNIT SCHEDULE
SELECTION RESULTS FAN ELECTRIC HEAT SOUND
MAX MIN FAN INLET SP DOWN SP MOTOR MOTOR FAN FAN HEAT EAT LAT HTR HTR HTR RAD DIS ATTEN
TAG MODEL SIZE CONTROLS PRIMARY PRIMARY CFM in.wg in.wg ARRANGE. TYPE VOLTS FLA HP CFM DEG F DEG F KW AMPS VOLT PH. STEPS MCA MOCP NC NC METHOD
CFM CFM
VAV-1-1 CFRQ-EH 1221E BY OTHERS 1250 280 1250 0.5 0.25 VERIFY ECM 277 5.5 314 1250 66.8 80.7 5.5 6.6 480 3 SCR 15.1 20 28 31 AHRI-885E
VAV-1-2 CFRQ-EH 1221 E BY OTHERS 1250 280 1250 0.5 0.25 VERIFY ECM 277 5.5 314 1250 66.8 80.7 5.5 6.6 480 3 SCR 15.1 20 28 31 AHRI-885E
VAV-1-3 CFRQ-EH 1221E Y OTHERS 1250 280 1250 0.5 0.25 VERIFY ECM 277 5.5 3/4 1250 66.8 80.7 5.5 6.6 480 3 SCR 15.1 20 28 31 AHRI-885E
VAV-2-1 CFRQ-EH 1219E BY OTHERS 1125 300 1125 0.5 0.25 VERIFY ECM 277 4.1 112 1125 66.0 80.0 5.0 6.0 480 3 SCR 12.6 15 30 28 AHRi-885E
VAV-2-2 CFRQ-EH 1219E I BY OTHERS 1125 300 11125 0.5 1 0.25 VERIFY I ECM 277 1 4.1 112 1 1125 1 66.0 80.0 1 5.0 6.0 480 3 SCR 12,6 1 15 30 28 1 AHRI-885E
VAV-3-1 CFR-EH 0811 E BY OTHERS 500 150 500 0,5 0.25 VERIFY ECM 277 2.6 1/3 500 65.1 87.2 3.5 4.2 480 3 SCR 8.5 15 24 21 AHRI-885E
VAV-4-1 CFR-EH 0811E BY OTHERS 650 320 650_ 0.5 0.25 VERIFY ECM 277 2.6 1/3 650 62.3 91.5 6.0 7.2 480 3 SCR 12.3 15 29 25 AHRI-885E
VAV-5-1 CFR-EH 0811E BY OTHERS 450 390 450 0.5 0.25 VERIFY ECM 277 2.6 1/3 450 56.3 87.9 4.5 5.4 480 3 SCR 10.0 15 22 20 AHRI-885E
VAV-6-1 CFR-EH 0811E BY OTHERS 450 225 450 0.5 0.25 VERIFY ECM 277 2.6 1/3 450 61.6 89.7 4.0 zlo._8 480 3 SCR 9.3 15 22 20 AHRI-885E
VAV-7-1 CFRQ-EH 1019E BY OTHERS 850 620 850 0.5 0.25 VERIFY ECM 277 4.1 1/2 850 59.0 81.3 6.0 7.2 480 3 SCR 14,2 15 28 24 AHRI-F85E
VAV-8-1 CFRQ-EH_ 1019E BY OTHERS 800 490 800 0.5 0.25 VERIFY ECM 277_ 4.1 1/2 800 57.8 75.6 4.5 5.4 480 3 SCR 11.9 15 26 22 AHRI-885E
VAV-9-1 CFRQ-EH 1221E BY OTHERS 1200 930 1200 0.5 0.25_ VERIFY ECM 277 5.5 3/4 1200 58.2 81-9 9.0 10.8 480 3 SCR 20.4 25 28 31 AHRI-885E
VAV-10-1 GFRQ-EH 1019E BY OTHERS 950 245 950 0.5 0.25 VERIFY ECM 277 4.1 1/2 950 66.1 81.1 4.5 5.4 480 3 SCR 11.9 15 29 25 AHRI-885E
VAV-10-2 CFRQ-EH 1019E BY OTHERS 950 245 950 0.5 0.25 VERIFY ECM 277 4.1 1/2 950 66.1 81.1 4.5 _5A 480 3 SCR 11.9 15 29 25 ,AHRI-885E
VAV-10-3 CFRQ-EH 1019E BY OTHERS 950 245 950 0.5 0.25 VERIFY ECM 277 4.1 1/2 950 66.1 81.1 4.5 5.4 480 3 SCR 11.9 15 29 25 AHRI-885E
VAV-11-1 CFRQ-EH 1019E BY OTHERS 815 410 815 0.5 0.25 VERIFY ECM 277 815 67.0 86.4 5.0 6.0 480 + SCR 12.
15 26 22 AHRI-885E
VAV-12-1 CFR-EH 0811E BY OTHERS 500 415 500 0.5 0.25 VERIFY ECM 277 660 57.6 82.9 4.0 4.8 480 15 24 21 AHRI-885E
VAV-13-1 CFRQ-EH 1221E BY OTHERS 1210 415 121T 0.5 0.25 VERIFY ECM 277 1210 67. g5!(2 6.0 480 3 SCR 14.4 15 :28 31 JAHRI-885E
2 �2 ) I _T
VAV- 3- CFRQ-EH 1221E Y 2T� 1210 415 1210 0.5 0.25 VERIFY ECM 277 1210 67.0 .011 6.0 480 3 15 8 31 AHRI-885E
V.J�_j CFR-EH 0811E B�OT3E3S 450 210 T50 0.5 0.25 VERIFY ECM 277 450 57.4 71.4 1 2.0 1 2.4 480 3 AHRLAR517
ALL BOXES INCLUDE:
FLAT FILTER&RACK
FOIL LINED FACTORY INSULATION
MAGNETIC CONTACTORS
NON-FUSED DOOR INTERLOCKING DISCONNECT
SHEET METAL ENCLOSURE FOR FACTORY MOUNTED CONTROLS(CONTROLS BY OTHERS)
CONTRACTOR TO VERIFY ALL HANDING PRIOR TO ORDER.
FACTORY STANDARD IS ARRANGEMENT #1.
ELECTRIC HEAT
ELECTRICAL CONTROL ENCLOSURE
CONTROL ENCLOSURE (SEE NOTES)
ni
PRIMARY
INDUCTION L
�> E CFR/CFRQ-EH CFR/CFRQ-EH
INDUCTION
PRIMARY
AIR
u
7ELECTRIC HEAT
'L
ELECTRICAL CONTROL ENCLOSURE
CONTROL ENCLOSURE (SEE NOTES)
ARRANGEMENT 1 El ARRANGEMENT 3
LEFT HAND CONTROL UNIT RIGHT HAND CONTROL UNIT
WITH LEFT HAND PRIMARY WITH RIGHT HAND PRIMARY
NOTES:
1. ELECTRIC HEAT CONTROL ENCLOSURE IS ON THE SAME SIDE AS STANDARD CONTROL ENCLOSURE.
2. ELECTRIC HEAT ONLY AVAILABLE ON ARRANGEMENTS 1 & 3.
3. ELECTRIC HEAT NOT AVAILABLE WITH HW COIL.
rM or4l r=1MVIRO-TEC"
ARRANGEMENTS - MODEL CFR/CFRQ 'A EMN109-11WE311NO FmCW4 EXO�
m ff* I lAl7J SC"' DPAWINO MM
JGH 11/3/04 1-1
00 NOT SCAL.E DRAW--
'M OONOE"MUT NOT= CX~Dn ItEr. 33-80015
UMMnMRM DOMMM.RMNMWXMK OR USE
5 SMMY PRDMM WffHWT=PMN=N 00
THS DROM CONTAPS PROPREEAW DATA.
CATALOG
CFR Series
Fan - Powered , VAV Terminals
NOTES: ELECTRONIC ENCLOSURE
1. Ail dimensions are Inches [millimeters]. TYPICAL ON UNITS WITH El ECTRIC: HEAT
ELECTRONIC CONTROLS,
All dimensions are ±1/4' [6mm]. Metric values are OPTIONAL ON UNITS WrrZH CONTROL ENCLOSURE,
soft conversion. PNEUMATIC CONTROLS (SEE NOTE 2)
2. Provide sufficient clearance to permit access to (SEE NOTE 2
controls and comply with applicable codes and
ordinances. 8
3. 1" (25mm] thick fiberglass TAW filter. See chart for sizes. E203]
This option not suitable for ducted return applications. -------- MAX
4. Inlet and outlet collars must be externally insulated in
the field "by others*, if required. 1.
5. Sizes 0404, 0504 and 0506 uses a single-oxis multi-point B
averaging airflow sensor and inlet collar extends 10-1/2*
[267mm] from unit casing.
6. Electric heater & outlet collar may extend a total of
12' [305] depending on options. $�E
7. Units with internal insulation in the downstream
ductwork should have insulation secured with no r
raw edges exposed to the airstream. OPTIONAL P1 ENUM 1 1
8. See drawing 33-80015 for arrangement details. AIR INLEr FILTER,_1
OPTION NOTES: (SEE NOTE 3) ELECTRIC HEATER,
9. Double wall (DW) option increases V dim. 1-1/2" [38mm] and SUP & DRIVE
reduces inlet and discharge collar length by 3/4" (19mm]. TOP VIEW COLLAR OPTIONAL
10. Low temperature (J) option provides a thermally isolated primary (SEE NOTE 6)
inlet. Inlet collar length is reduced by 3/4' (19mm]. UNIT FILTER SIZE
11. Low temperature (LT) option is suitable for 46! F min. primary SIZE INCHES [MM]
air and max. ambient conditions of 78* F and 60% RH.
0404 Thru 0604 12 X 7 X 1 [305 X 178 X 25]
VAV-3-1,4-1,5-1,6-1,9-1,1 2-1,14-1 0506 Thru 0811 13 X 14 X 1 [330 X 356 X 25]
1011 11 X 14 X 1 [279 X 356 X 25]
VAV-1-1,1-2,1-3,2-1,2-2,7-1,8-1,10-1,10-2,10-3,11-1,13-1,13-2 0818 Thru 1221 15 X 17 X 1 [381 X 432 X 25]
1421 13 X 17 X 1 [330 X 432 X 25]
PLENUM AIR INLET 1224 & 1424 19 X 19 X 1 [483 X 483 X 25
WITH OPTIONAL RADIATED
SOUND DAMPER TYP. 5/8 [16] OUTLET
PRIMARY [2 1 5] FLANGE TYP. (3) SIDES
AIR INLET F 7 C
H/2
I Y
I H-2
I I _j
FLOWSTART" MULTI- L
POINT AIRFLOW
SENSOR WITH 1 6
EXTERNAL BALANCE A 6-1/2 [165] L
TAPS, (SEE NOTE 5) P E25] (SEE NOTES 4,5,9,10) (SEE NOTE 9)___� (152]
_W_ (SEE NOTES 4.6)
INUET EEND NnEW ZFULL BOTTOM ACCESS
SGL PANEL-FAN SZ 04, 06 & 11
(Filter not shown this view) DBL PANEL-FAN SZ 18 & UP
SlDr= Vft-W
DIMENSIONS - In [mml
UNIT H W L X Y A B C P UNIT I
SIZE - 12 18 28 8-3/8 8 6 5 3/4 5 SIZE 3-7/8
0404, 0504, 0604, (305] (457] [711] (2131 [2031 [1521 (127] (19) [127) 04XX (98]
0506, 0606, 0806, 14 23-3/8 35 11 11 6 2-1/4 3/4 11 4-7/i-
0611, 0811 [3561 [5941 (889) [7791 [279] [1521 [57] [19) [279] 05XX (124]
1011 14 23-3/8 35 11 11 7 2-1/4 3/4 5-7/8
(3561 1 [65941 (8891 1 [2791 [2791 1 (178) [57] [191 [2291 06XX [1491
0818, 1018, 1218, 17 29-3/8 40 15 13-1/2 8 2-1/4 3/4 13 7-7/8
1021, 1221 [4,321 [7461 (1018) [381) [343] (2031 [571 (19] 1=1 08XX (200]
17 29-3/8 40 15 13-1/2 9 2-1/4 3/4 11 9-7/8
1421 [4321 [7461 [1018] (381] (343] [2291 [571 (193 (2791 1OXX [2511
1224, 1424 19 38 54 28 15 10 2-1/4 3/4 17 11-7/8
14831 [9653 [13721 (7111 [381] [25*) (571 [19] (4321 12XX [3021
13-7/
14XX [3521
UNIT SIZE:
FIRST 2 DIGITS DENOTE PRIMARY INLET SIZE, SECOND 2 DIGITS DENOTE FAN AND CASING SIZE.
MODEL CFR-EH SERIES FLOW FENVIRO.Trm'
FAN POWERED TERMINAL
SIZES 0404 THRU 1424 BY JOHNSON CONTROLS
ARGT 1 4-� NOTE D101 BY. DATL - No.
TM ORAWW CONNNS PR�ErAAY DATA. 00 NOT SCAL-E DRAW, DVG 10/31/08 1=25
UNAL4HDFd=DMCLCSURF-FRPRODUCT10K OR USE DIMOMM AND DArA ARE SUBJWr TO CHANM WffMUT NOME CKD BY:
Dpa I DAM I/W I KV�1
r.STRICILY MH18M 110MOV WRffM PERMSION COWICT FACMRY FDR CERTIM DPAMGS. 10/3 0 33-80006
ELECTRONIC ENCLOSURE
ELECTRIC HEAT TYPICAL ON UNITS WITH NOTES:
CONTROL ENCLOSURE, ELECTRONIC CONTROLS, 1. All dimensions are Inches [millimeters].
OPTION L ON UNITS WITH All dimensions are ±1/4* [6mm]. Metric values are
(SEE NOTE 2) PNEUMA�TIC CONTROLS soft conversion.
EE NOTE 2) 2. Provide sufficient clearance to permit access to
(2031 controls and comply with applicable codes and
MAX Vinances.
3. 1 [25mm] thick fiberglass TAW filter. See chart for sizes.
This option not suitable for clucted return applications.
4. Inlet and outlet collars must be externally insulated in
_j the field *by others', if required.
8 5. Sizes 0404, 0504 and 0506 uses a single—axis multi—point
averaging airflow sensor and inlet collar extends 10-1/2"
[267mm] from unit casing.
6. Electric heater & outlet collar may extend a total of
X E14 12' (305] depending on options.
4 7. Units with internal insulation in the downstream
ductwork should have insulation secured with no
OPTIONAL PLENUM raw edg?s exposed to the airstream.
I—AIR INLET FILTER. 8. See drawing 33—BOO15 for arrangement details.
(SEE NOTE 3)
ELECTRIC HEATER, OPTION NOTES:
SUP & DRIVE 9. Double wall (DW) option increases "L" dim. 1-1/2" [38mm] and
COLLAR OPTIONAL TOP VIEW reduces inlet and discharge collar length by 3/4" (19mmj.
(SEE NOTE 6) 10. Low temperature (J) option provides a thermally isolated primary
UNIT FILTER SIZE inlet. Inlet collar length is reduced by 3/4" (19mm].
11. Low temperature (J) option is suitable for 46' F min. primary
SIZE INCHES [MM] air and max. ambient conditions of 76 F and 60% RH.
0404 Thru 0604 12 X 7 X 1 [305 X 178 X 25]
0506 Thru 0811 13 X 14 X 1 [330 X 356 X 25]
1011 11 X 14 X 1 [279 X 356 X 25
0818 Thru 1221 15 X 17 X 1 (381 X 432 X 25]
1421 13 X 17 X 1 [330 X 432 X 25]
PLENUM AIR INLET
1224 & 1424 19 X 19 X 1 (483 X 483 X 25] WITH OPTIONAL RADIATED
SOUND DAMPER
5/8 [16] OUTLET [25] PRIMARY
NGE (3) SIDES r TYP. AIR INLET
I I I H/2
H .2 1
_j 1
FLOWSTARr"MULTI—
POINT AIRFLOW
C SENSOR WITH
12 5] A EXTERNAL BALANCE
6 L 6-1/2 (165] w TAPS, (SEE NOTE 5)
(152] — (SEE NOTE 9)— (SEE NOTES 4,5,9,10)
(SEE NOTES 4,15)
FULL BOTTOM ACCESS,�
SGL PANEL—FAN SZ 04, 06 & 11 INUET EENE) V9_:NV
DBL PANEL—FAN SZ 18 & UP (Filter not shown this view)
SIDE VIEW DIMENSIONS - In [mml
UNIT H w L X Y A 8 C P UNIT I
SIZE SIZE
12 is 28 8-3/8 a 6 5 3/4 5 3-7/8
0404, 0504, 0604, 1305] [457) (7111 [2131 (2031 [152] (127] 1191 [127) 04XX 1981
0506, 0606, 0806, 14 23-3/8 35 11 11 6 2-1/4 3/4 11 4-7/8
0611, 0811 (356] [5941 [sag] (2791 [2791 [152] [571 (191 [279] 05XX (124]
1011 14 23-3/8 35 11 11 7 2-1/4 3/4 9 5-7/8
[3561 [85941 (8891 (279] [2791 [178] 1 [57] (191 1 [2291 06XX (149]
0818, 1018, 1218, 17 29-3/8 40 15 13-1/2 8 2-1/4 3/4 13 7-7/8
1021, 1221 14321 [746] [1016] (381] 1301 [203] [57] [19] (330] 08XX [2001
1421 17 29-3/8 40 15 13-1/2 9 2-1/4 3/4 11 iOxX 9-7/8
14321 (7461 [1018] [381] [3431 (2291 [571 [19] [2791 [251]
1224, 1424 19 38 54 28 15 10 2-1/4 3/4 17 11-7/8
[4831 (9651 [13721 [7111 [3811 12541 i2XX
(57) [19] [4321 [_ 13021
14XX 13-7/8
[3521
UNIT SIZE:
FIRST 2 DIGITS DENOTE PRIMARY INLET SIZE, SECOND 2 DIGITS DENOTE FAN AND CASING SIZE.
717M. MODEL CFR—EH SERIES FLOW FEMVIRO-TFEC'
FAN POWERED TERMINAL
SIZES 0404 THRU 1424 BY JOHNSON CONTROLS
ARCT 3 4— NOTE Do Irf: DAM SCA, 0"111111110 N&
DVG 10/31/08 1=25
DM 10/3 02
00 NOT SCAL-E DRAWING CKD BY. DATE' wv�
KNffH0F1IZM DISCLOWRE REF-RODUMON,OR USE XM AM DATA AK SUBJEcr M CK.NM WTTHOUT NOnM
IS SRCMY PRMISM*IM=WRnTM PEM=;0N__T__ cwAcT FAcmw mit cmm oitwic&IT t/08 33-80007
THIS DRAWM CONTAM PROPRIETAV DATA.
U
FAN PERFORMANCE DATA-MODEL CFR, ECMT- MOTOR
E.S.P. UNIT SIZES 0818, 1018, 1218
E.S.F. (IN W.G.)
(IN.W.G.) UNIT SIZES 0611, 0811, 1011 1,0-
0.9
0.9-
0.8-- 0.8-
0.7- 0.7-
0.6- 0.6-
0.5- O�5-
0.4- 0.4-
0.3-- 0.3---
0.2-
0,2
01
0 1
0.0
150 300 450 600 750 900 0,0
AIRFLOW CFM(Standard Density Air) 500 600 700 800 900 1000 1100 1200 1300 1400 1500
AIRFLOW CFM(Standard Density Air)
E.S.P.
(IN W.G.) U NIT SIZES 1021, 1221, 1421
1.0-
0.9-
0.8
0.7
0.6
0.5
0.4
03
0.2
0.1
0.0
600 800 1000 1200 1400 1600 1800 2000
AIRFLOW CFM(Standard Density Air)
UNIT SIZES 0611, 0811, 1011 0818, 1018, 1218 1021, 1221, 1421
HORSEPOWER (HP) 1/3 1/2 3/4
AMPS @ 129 VG6:FG 6.9 7.7 9.6
L AMPS @ 277 VOLTS 2.6 4.1 5.5
NOTES:
1. Each fan curve depicts the actual performance without any additional fan balance adjustment. Actual specified
capacities which fall below the particular fan curve can be obtained by adjustment of the electronic fan speed
controller.
2. Selection can be made anywhere in the non-shaded area.
3. Terminals equipped with a hot water coil require the addition of the coil pressure drop and the specified E.S.P.
prior to making a fan selection.
SUBMITTAL DRAWING TITLE: FAN PERFORMANCE DATA
AffENVIRO-TECO ALL DRAWINGS ARE SUBJECT TO CHANGE
161, WITHOUT PRIOR NOTICE MODEL CFR, ECM MOTOR
BY JOHNSON CONTROLS DO NOT SCALE DRAWING DATE SHEET 1 0 �DRAWING NO REV
THIS DRAWING CONTAINS PROPRIETARY DATA.UNAUTHORIZED DISCLOSURE. DIMENSIONS ARE IN INCHES UNLESS
REPRODUCTION.OR USE IS STRICTLY PROHIBITED WITHOUT WRIT-TEN PERMISSION. OTHERWISE NOTED C PAGE F2 06-80040 00
Catalog: ET130.13-EG4 (908) Series Fan-Powered, VAV Terminals
CONSTRUCTION FEATURES
MODEL CFR
The CFR terminal incorporates many unique features. Most of these standard features are expensive
options for other manufacturers.
Integral discharge collar Electrical devices
simplifies field installation F installed within a
NEMA 1 enclosure,
with single point
power connection
Fan assembly utilizes a forward curved,
dynamically balanced,galvanized wheel
with a direct drive motor
All unit configurations
Mechanical lock construction listed with ETL for
ensures lowest possible safety compliance Galvanized steel casing withstands 125 hour
casing leakage salt spray test per ASTM B-1 17
Product label includes
Mechanically fastened
tagging, airflow, and
insulation for added
electrical information security
3/4"thick fiberglass
Full bottom removable 4
access panels insulation complying
with LIL 181, NFPA 90A,
and ASTM C1 071
Low leakage damper incorporates closed
cell foam gasket
Roll formed inlet collar with integral Patented FlowStarTm airflow sensor
stiffening ribs adds strength and rigidity (Patent#5,481,925)
OPTIONAL CONSTRUCTION FEATURES
• ECMTM fan motor 4
• M001 Itil 19 111 clukutS tu Muctlit dli-tl n ucid I cm yi, y ,ods u, vvii e 1 id,iyen)
• Betible well eemotFinjet2eig
• Scrim reinforced foil faced insulation meeting ASTM C1136 for mold, mildew, and humidity resistance
• BastemeFie elesed eeli fea ' i8t6819
• Filter located at induction inlet
1 IUt W.3te, (eFR W13), steam-,-tyr lelectric heating coils (CFR-EHI mounted at unit discharge.AGG966 plate
bipStFeaffl Of h�'EIFORiS 68il iS StBRE18F .
Lo��ture_construction for use in thermal storage applications. Includes thermally isolated r
"'r "o 'y
inlet and compos le a
to t �*" eum atic
Factory control op ions: analog electronic, eumatic
i
Factory piping pack
itv C full co I a co itio
I r v mD u s
in et gravity damper reduces rad�iated NC level byy up to 2 NC at full cooling condition.
4 Johnson Controls
Series Fan-Powered, VAV Terminals Catalog: ET130.13-EG4 (908)
CONSTRUCTION FEATURES
ACCURATE AND ENERGY-SAVING AIRFLOW CONTROL
WITH THE PATENTED FLOWSTAR TM SENSOR
Many VAV terminals waste energy due to an inferior airflow sensor reduces energy consumption by allowing
airflow sensor design that requires the minimum CFM lower zone minimum CFM setpoints, greatly reducing
setpoint to be much higher than the IAQ calculation or eliminating"reheat", and by imposing less resistance
requirement. This is common with interior spaces that on the primary air fan.
will be effected year round. These interior VAV terminals The ENVIRO-TECO' air valve features the FlowStar TM
waste energy in several ways. First, the primary air fan airflow sensor which has brought new meaning to airflow
(e.g.AHU)supplies more CFM than the building requires. control accuracy.The multi-axis design utilizes between
The higher minimum CFM setpoint overcools the zone 12 and 20 sensing points that sample total
with VAV terminals without integral heat. To maintain pressure at center points within equal concentric cross-
thermal comfort a building engineer would need to
change the minimum setpoint to zero CFM compromis- sectional areas, effectively traversing the air stream in
ing indoor air quality. Interior VAV terminals with integral two planes. Each distinct pressure reading is averaged
heat provide adequate comfort in the space but waste within the center chamber before exiting the sensor to
significant energy as energy is consumed to mechani- the controlling device.
cally cool the primary air only to have more energy This sensor adds a new dimension to signal amplifica-
consumed to heat the cooled primary air. Significant tion. Most differential pressure sensors provide a signal
energy savings is obtained with proper sizing and by between .5 and 2 times the equivalent velocity
making sure approved VAV terminals are capable of pressure signal. The FlowStar TM provides a differential
controlling at low CFM setpoints, providing the minimum pressure signal that is 2.5 to 3 times the equivalent
ventilation requirement. velocity pressure signal. This amplified signal allows
Currently, most DDC controllers have a minimum differ- more accurate and stable airflow control at low airflow
ential pressure limitation between 0.015"and 0.05"w.g. capacities. Low airflow control is critical for indoor air
The major DDC manufacturers can control down to 0.0 15" quality,reheat minimization,and preventing over cooling
w.g. An airflow sensor that does not amplify, e.g., a Pitot during light loads.
tube, requires about 490 FPM to develop 0.015" w.g. Unlike other sensors which use a large probe surface
differential pressure. The FlowStarTm develops 0.015" area to achieve signal amplification, the FlowStarTM
w.g.pressure with only 290 FPM on a size 6 terminal and utilizes an unprecedented streamline design which
less than 325 FPM for a size 16. Consequently, VAV generates amplified signals unrivaled in the industry.
terminals utilizing a non-amplifying type sensor could The streamlined design also generates less pressure
have minimum CFM's that are well over 50%higher than drop and noise.
an ENVIRO-TEC'�'terminal. Many airflow sensors provide The VAV schedule should specify the minimum and
some degree of amplification simply due to the decrease maximum airflow setpoints, maximum sound power
in free area of the inlet from large area of the sensor. levels,and maximum air pressure loss for each terminal.
These VAV terminals still require minimum CFM's up to The specification for the VAV terminal must detail the
30% higher than an ENVIRO-TECO terminal, have high- required performance of the airflow sensor. For maxi-
er sound levels, and higher pressure drop requiring mum building occupant satisfaction, the VAV system
additional energy consumption at the primary air fan. designer should specify the airflow sensor as suggested
A VAV system designed with ENVIRO-TECI" terminals in the Guide Specifications of this catalog.
consumes significantly less energy than a comparable FlowStar Tm Airflow Sensor Patent#5,481,925
system with competitor's terminals. The FlowStarTm
........... Each pressure input signal is routed Field pressure
.... ................... to the center averaging chamber measuring tap
Equal concentric circular areas
....... ......
Sizes 6&8: 3 Circles Airfoil shaped
Sizes 10&12: 4 Circles averaging
Sizes 14&16: 5 Circles(shown) chamber for low
pressure loss rim
and noise
Total pressure measured at the center
of each concentric circle for maximum Pressure output
accuracy,as outlined in ASHRAE is
routed behind
Fundamentals Handbook.
Sizes 6&8: 12 Sensing Points probe to minimize
........... Sizes 10& 12: 16 Sensing Points pressure loss
Sizes 14&16: 20 Sensing Points and noise
Johnson Controls 5
Series Fan-Powered, VAV Terminals Catalog: ET130.13-EG4 (908)
ELECTRIC HEAT
MODEL CFR-EH
STANDARD FEATURES
• cETL listed as an assembly for safety compliance
per UL 1995
• Primary auto-reset high limit
• Secondary high limit
• Hinged control panel
• Ni-Chrome elements
• Primary/secondary power terminations
• Fusing per NEC
• Wiring diagram and ETL label
• Fan interlock device (relay or P.E. switch)
• Single point power connection
• Available kW increments are as follows:
0.5 to 5.0 kW - .25 kW; 5.0 to 10.0 kW - .50 kW; SELECTION PROCEDURE
Above 10 kW - 1.0 kW With standard heater elements, the maximum capacity(kW)
is obtained by dividing the heating (fan) SCFM by 70. In
OPTIONAL FEATURES other words, the terminal must have at least 70 SCFM per
Disconnect (toggle or door interlocking) kW. In addition, each size terminal has a maximum allow-
P.E. switches able kW based upon the specific heater element
Mercury and magnetic contactors configuration (i.e. voltage, phase, number of steps, etc.).
Manual reset secondary limit Contact your ENVIRO-TEC(" representative or refer to the
Proportional control (SSR) ENVIRO-TEC�-_ Winclowsc' based computer selection pro-
24 volt control transformer gram for design assistance.
Airflow switch
Heaters require a minimum of 0.07"w.g. downstream static
MAXIMUM ALLOWABLE KW pressure to ensure proper operation.
UNIT SIZE MAX CFM MAX kW For optimum diffuser performance in overhead heating
0404 250 3 applications, the supply air temperature should be within
0504 350 5 20'F of the desired space temperature. This typically
0604 400 5 requires a higher air capacity which provides higher air
0506 350 5 motion in the space increasing thermal comfort. The electric
0606 550 7 heater should be selected with this in mind, keeping the LAT
0806 700 10 as low as possible.
0611 500 7
0811 1000 14 Selection Equations
1011 1200 17 kW = SCFM x AT x 11.085�
0818 1000 14 3413
1018 1600 22
1218 1800 25 CFM = _kW x 3413
1021 1600 22 AT x 1.085*
1221 2300 30
1421 2300 30 AT = kW x 3413
1224 2300 20 SCFM x 1.085*
1424 2600 25
1230 2300 20 *Air density at sea level-reduce by 0.036
1430 3100 30 for each 1000 feet of altitude above sea level.
1630 3100 30
1440 3100 30 Calculating Line Amperage
1640 4100 35 Single Phase Amps = kWx1000
1644 4100 40 Volts
1844 4600
Three Phase Amps = kW x 1000
Volts x 1.73
Johnson Controls 23
CATALOG
CFRC) Extra Quiet Series Flow
' I I�ft f
Constant Volume Fan Powered
VAV Terminals
NOTES:
1. All dimensions are Inches [millimeters]. ELECTRONIC ENCLOSURE
All dimensions are ±1/4" (6mm]. TYPICAL ON UNITS WITH ELECTRIC HEAT
El ECTRONIC CONTROLS,
Metric values are soft conversion. OPTIONAL ON UNIT wrrH--7 CONTROL ENCLOSURE,
CO�
NTR
2. All drawings subject to change without PNEUMATIC ZOLS SEE NOTE 4
prior notice. SEE NOTE
3. Electric heater may extend to a total of
12* (305mm) depending on options. 8
4. Provide sufficient clearance to permit [2031
access to controls and comply with r----------T_ MAX
applicable codes and ordinances.
5. 1" [25mm] thick fiberglass TAW filter.
See chart for sizes. B
6. Inlet collar and electric heater must
be externally insulated in the field
"by others% if required.
7. Units with internal insulation in the downstream E X
ductwork should have insulation secured with
no raw edges exposed to the airstream. F
8. See drawing 33-80015 fr arrangement details. OPTIONAL PLENUM I I
AIR INLET FILTER,-1
UNIT FILTER SIZE SEE NOTE 5 1 5/8
SIZE INCHES [MM] [16]
TYP.
0606 Thru 0811 13 X 14 X 1 [330 X 356 X 251
TOP VIIIEW
1011 11 X 14 X 1 [279 X 356 X 25]
OPTION NOTES:
0817 Thru 1421 15 X 17 X 1 [381 X 432 X 25] 9. Double wall (DW) option increases V dim. 1-1/2* [38mm] and
-F reduces inlet and discharge collar length by 3/4" [19mm].
1224 & 1424 19 X 19 X 1 [483 X 483 X 25] 10. Low temperature (LT) option provides a thermally isolated primary
inlet. Inlet collar length is reduced by 3/4' [19mm].
11. Low temperature (LT) option is suitable for 46' F min. primary
FLOWSTAR' MULTI-POINT air and max. ambient conditions of 78' F and 60% RH.
AIRFLOW SENSOR WITH
EXTERNAL BALANCE TAPS
PRIMARY PLENUM AIR INLET WITH
AIR INLET RADIATED SOUND DAMPER 5/8 [16] OUTLET
25] FLANGE TYP. (3) SIDES7C -,
TYP.
H/2
H-2 I Y
I L E
L
A P 6-5/8 L 6 [152]
[25] [168] SEE NOTE 3
W ZFULL BOTTOM ACCESS
SGIL PANEL-FAN SZ 06 & 11
INLET END VIEW DBL PANEL-FAN SZ 17 & UP
(Filter not shown this view) 810e y1le1w
DIMENSIONS - In [mml
UNIT UNIT
SIZE H W L X Y A B C P SIZE I
0606, 0806, 14 23-3/8 35 11 11 6 3-1/4 3/4 10-3/8 5-7/8
0611, 0811 [356] [594] (889] [279] [279] (152] 1831 [19] (264] 06XX [149]
14 23-3/8 35 11 11 7 3-1/4 3/4 B-3/8 7-7/8
1011 (356] [594] [889] 1279] [279) (178] [83] [19] [213] O8XX [200]
0817. 1017, 1217 [17] 29-3/8 40 15 13-1/2 8 3-7/8 3/4 12-3/8 9-7/8
432 [746] [1016] [381] (343] (203] 1981 (19] [314) 11OXX [251]
0819, 1019, 1219 17 29-3/8 40 15 13-1/2 8 3-1/2 3/4 12-3/8 11-7/8
14-32] [746] (1016] 1381] [343] (203] (891 [19] [314] 12XX [302]
1021, 1221, 17 35-3/8 40 15 13-1/2 9 11-1/2 2-3/4 12-3/8 13-7/8
1421 [432] [899] (1016] [381] [343] (229] [292] [70] [314] 14XX [352]
1224, 1424 19 47-3/8 [150 [28] 15 9 ] 1 (12 3-1/4 [17
1 1483] 1 [1203] 270] 711 (3811 [229 3 [83] 432
UNIT SIZE: FIRST 2 DIGITS DENOTE PRIMARY INLET SIZE, SECOND 2 DIGITS DENOTE FAN AND CASING SIZE.
T".
MODEL CFRQ-EH EXTRA QUIET 10i r=NV1R0.TF_C*
SERIES FLOW FAN POWERED TERMINAL BY JOHNSON CONTROLS
FAN SIZES 06 THRU 24, ARGT 1 .4— NOTE DRN BY: DATE
DvG 4/1;/09 —1-24
MC� NCMrT 611K=JkLM MPtAk'Anm5i
NOT FOR 0DNsiRuqnoK CDNTACT FACMRY FDR CEITIVIIED DRAWING& CKD VY: DATE:
DRAENSKM AND DATA AK SUBJWT M MANGE WIMOLff NDnM I DPB 4/6/09 oo 33-80040
NOTES:
ELECTRONIC ENCLOSURE 1. All dimensions are Inches [millimetersl-
ELECTRIC HEAT TYPICAL ON UNITS WITH All dimensions are ±11/4" [6mm].
CONTROL ENCLOSURE, ELECTRONIC CONTROLS, Metric values are soft conversion.
OPT 2. All drawings subject to change without
SEE NOTE 4 PNE=,CON UNITS WITH access to controls and comply with
CONTROLS prior notice.
E NOTE 4 3. Electric heater may extend to a total of
12" (305mm) depending on options.
[2031 4. Provide sufficient clearance to permit
MAX 7 applicable codes and ordinances.
T__fl—————— 1 5. 1" [25mm] thick fiberglass TAW filter.
See chart for sizes.
B 6. Inlet collar and electric heater must
AIR be extemally insulated in the field
'W' "by others", if required.
7. Units with internal insulation in the downstream
ductwork should have insulation secured with
no raw edges exposed to the airstream.
OPTIONAL PLENUM 8. See drawing 33-80015 for arrangement details.
I—AIR INLET FILTER, UNIT FILTER SIZE
5/8 SEE NOTE 5 SIZE INCHES [MM]
TYP. 0606 Thru 0811 13 X 14 X 1 (330 X 356 X 25]
TOP VIEW 1011 11 X 14 X 1 (279 X 356 X 25]
OPTION NOTES: 0817 Thru 1421 15 X 17 X 1 [381 X 432 X 251
9. Double wall (DW) option increases V dim. 1-1/2" (38mm] and
reduces inlet and discharge collar length by 3/4" [19mm]. 1224 & 1424 19 X 19 X 1 483 X 483 X 25]
10. Low temperature (J) option provides a thermally isolated primary TI
inlet. Inlet collar length is reduced by 3/4" [19mm].
11. Low temperature (J) option is suitable for 46* F min. primary
air and max. ambient conditions of 78' F and 60% RH. FLOWSTAe MULTI—POINT
AIRFLOW SENSOR WITH
EXTERNAL BALANCE TAPS
PLENUM AIR INLET WITH PRIMARY
5/8 [16] OUTLET RADIATED SOUND DAMPER— AIR INLET
LANGE TYP. (3) SIDES 1
[25]
TYP.I I
H/2
Y 1 2
I—L J-11
L c
6 [152] L 6-5/8 [215] A
SEE NOTE 3— L [168]
FULL BOTTOM ACCESS W
SGL PANEL—FAN SZ 06 & 11 \
DBIL PANEL—FAN SZ 17 & UP INLET END VIEW
SIDE %AEW (Fi Iter not shown this view)
DIMENSIONS In [mm]
UNIT
SIZE H W L X Y A B C P INLET I
0606, 0806, 14 23-3/8 35 11 11 6 3-1/4 3/4 10-3/8 5-7/8
0611, 0811 [356] [594] (889] [279] (279] [1521 [83] [19] [2641 06XX [1491
1011 14 23-3/8 35 11 11 7 3-1/4 3/4 8-3/8 08XX 7-7/8
(356] (594] [889] [279] (279] [178] 1831 [19] (213] [200]
0817, 1017, 1217 17 29-3/8 40 15 13-1/2 8 3-7/8 3/4 12-3/8 1OXX 9-7/8
[4321 [7461 [10161 [381] [3431 (2031 [98] [19] (314) [2511
0819, 1019, 1219 17 29-3/8 40 15 13-1/2 8 3-1/2 3/4 12-3/8 12XX 11-7/8
1432] [746] [1016] [381] (343] [203] [89] (19] (314] [302)
1021, 1221, 17 35-3/8 40 15 13-1/2 9 11-1/2 2-3/4 12-3/8 14XX 13-7/8
1421 [432] (899] [10161 [381] (343] [229] [2921 [701 (3141 [3521
1224, 1424 19 47-3/8 50 28 15 9 12 3-1/4 17
1 [483] 1 [1203] 1 [1270] 1 (711] 1 ( 81] 1 [229] 1 (305] 1 [83] 1 [432]__j
UNIT SIZE:
FIRST 2 DIGITS DENOTE PRIMARY INLET SIZE, SECOND
2 DIGITS DENOTE FAN AND CASING SIZE.
MODEL CFRQ—EH ini r=NVIRO-TF-C'
EXTRA QUIET SERIES FLOW
FAN POWERED TERMINAL FAN BY JOHNSON CONTROLS
M WY: DAM WAI DRAWWO NO.
SIZES 06 THRU 24, ARGT. 34— NOTE
CK:0 w:rr 41C=AJLM CIMAWNCA DVG 4/6/09 1-24
WT FOR CONSTR=10K CWACT FAC�FOR CMM DRAWNGS. C"DY: I DATE:/09 M.
DWOMONS AND DATA ARE SUBJECT TO CKV40E*ITFOff NOME DP8 4/6 1 00 33-80044
4
IjFk4I ENVIRO-TEC
CFRQ CONSTRUCTION FEATURES
BY JOHNSON CONTROLS
Model CFRQ
The CFRQ terminal incorporates many unique features. Most of these standard
features are expensive options for other manufacturers.
Integral discharge
collar simplifies field Electrical devices
installed within a
installation
NEMA 1 enclosure,
with single point
power connection
Fan assembly utilizes a forward curved, dynamically
balanced, galvanized wheel with a direct drive motor
Mechanical lock All unit configurations
construction ensures listed with ETL for
lowest possible safety compliance Galvanized steel casing withstands 125
casing leakage hour salt spray test per ASTM B-1 17
Product label includes Mechanically fastened
tagging, airflow, and insulation for added
electrical information
security
Full bottom removable 3/4" thick fiberglass
access panels insulation complying
22� with UL 181, NFPA 90A,
and ASTM C1 071
Radiated sound damper
Low leakage damper incorporates Patented FlowStarT" airflow sensor
closed cell foam gasket Roll formed inlet collar with (Patent #5,481,925)
integral stiffening ribs adds
strength and rigidity
Optional Construction Features
ECM fan motor
Aq WaEkets te OIEEept all thiPead haFigimg Fe&o; A-F;.vire haRqeFS
AMR EA-RS41-14ime-A
Scrim reinforced foil faced insulation meeting ASTM C1 136 for mold, mildew, and humidity resistance
Elasteme& e ele!qed eel' +aam
Filter located at induction inl
et
* Hot wateF (CPR WC), steam, jelectric heating coils (CFIR-ELF1114 mounted at unit discharge. Acc@&& pla4e ups4eam
. nt!oof-��LQnstruction for use in thermal storage applications. Includes thermally isolat r
inlet and composit'! Timper s a
W - Factory control options: a imatic
pac ages (refer to Piping Packages catalog)
4 Johnson Controls
k"
,44,1 ENVIRO-TEC
CONSTRUCTION FEATURES CFRQ '
BY JOHNSON CONTROLS
Accurate and Energy-Saving Airflow Control
With The Patented FlowStar T11 Sensor
.....................
.................I..................... Each pressure input signal is routed Field pressure
to the center averaging chamber measuring tap
.. .......................
Equal concentric circular areas
.......... ....... Sizes 6&8: 3 Circles
Sizes 10& 12: 4 Circles Airfoil shaped
averaging
Sizes 14&16: 5 Circles(shown) chamber for low
pressure loss
and noise
Total pressure measured at the center
J
of each concentric circle for maximum
..... ....... accuracy,as outlined in ASHRAE Pressure output is
Fundamentals Handbook. routed behind
............. Sizes 6&8: 12 Sensing Points probe to minimize
Sizes 10& 12: 16 Sensing Points pressure loss
Sizes 14& 16: 20 Sensing Points and noise
Many VAV terminals waste ener- ufacturers can control down to The ENVIRO-TEC'air valve features the Flow-
Star"airflow sensor which has brought new
gy due to an inferior airflow 0.015"w.g. An airflow sensor that meaning to airflow control accuracy. The
sensor design that requires the does not amplif�e.g., a Pitot tube, multi-axis design utilizes between 12 and
minimum CFM setpoint to be requires about 490 FPM to devel- 20 sensing points that sample total
much higher than the IAQ cal- op 0.015" w.g. differential pressure at center points within equal
culation requirement. This is pressure. The FlowStar develops concentric cross-sectional areas,effectively
traversing the air stream in two planes. Each
common with interior spaces 0.015"w.g. pressure with only 290 distinct pressure reading is averaged with-
that will be effected year round. FPM on a size 6 terminal and less in the center chamber before exiting the
These inferior VAV terminals waste than 325 FPM for a size 16. Con- sensor to the controlling device.
energy in several ways. First, the sequently,VAV terminals utilizing This sensor adds a new dimension to
primary air fan (e.g.AHU)supplies a non-amplifying type sensor signal amplification. Most differential
more CFM than the building could have minimum CFM's that pressure sensors provide a signal between
requires. The higher minimum are well over 50% higher than an .5 and 2 times the equivalent velocity
CFM setpoint overcools the zone ENVIRO-TEC terminal. Many air- pressure signal. The FlowStar'" provides
with VAV terminals without inte- flow sensors provide some degree a differential pressure signal that is 2.5 to
gral heat. To maintain thermal of amplification simply due to the 3 times the equivalent velocity pressure
signal. This amplified signal allows more
comfort a building engineer would decrease in free area of the inlet accurate and stable airflow control at low
need to change the minimum set- from large area of the sensor. airflow capacities. Low airflow control is
point to zero CFM compromising These VAV terminals still require critical for indoor air quality, reheat
indoor air quality. Inferior VAV minimum CFM's up to 30% high- minimization, and preventing over cool-
terminals with integral heat pro- er than an ENVIRO-TEC terminal, ing during light loads.
vide adequate comfort in the have higher sound levels, and Unlike other Sensors which use a large
space but waste significant ener- higher pressure drop requiring probe surface area to achieve signal
gy as energy is consumed to additional energy consumption at amplification, the FlowStar'" utilizes an
mechanically cool the primary the primary air fan. unprecedented streamline design which
air only to have more energy generates amplified signals unrivaled in the
- industry. The streamlined design also
consumed to heat the cooled A VAV system designed with generates less pressure drop and noise.
primary air. Significant energy sav-
ings is obtained with proper ENVIRO-TEC terminals con- The VAV schedule should specify the
sizing and by making sure sumes significantly less energy minimum and maximum airflow setpoints,
approved VAV terminals are capa- than a comparable system with maximum sound power levels, and
ble of controlling at low CFM competitor's terminals. The maximum air pressure loss for each terminal.
The specification for the VAV terminal must
setpoints, providing the mini- FlowStar airflow sensor reduces detail the required performance of the
mum ventilation requirement. energy consumption by allowing airflow sensor. For maximum building
lower zone minimum CFM set- occupant satisfaction, the VAV system
Currently, most DDC controllers points, greatly reducing designer should specify the airflow sensor
as suggested in the Guide Specifications
have a minimum differential pres- or eliminating"reheat", and by of this catalog.
sure limitation between 0.015"and imposing less resistance on the FlowStar" Airflow Sensor
0.05"w.g. The major DDC man- primary air fan. F Patent #5,481,925
Johnson Controls
ll,F,41 ENVIRO-TEC"
BY JOHNSON CONTROLS FAN PERFORMANCE, E CM TIVI MOTOR CFRQ
General Fan Note
The fan curves depicted on this page are for ECMT" type motors. Actual specified capacities which fall below the
fan curve can be obtained by adjustment of the fan speed controller. Selections should only be made in the
non-shaded areas. The minimum external static pressure requirement is shown for each fan assembly. The unit fan
should not be energized prior to realizing this minimum external static pressure.
Terminals equipped with a hot water heating coil require the addition of the coil pressure drop to the specified
external static pressure before making the fan selection.
E.S.P. F-S.P. UNIT SIZES 0819,1019,1219
(IN.W.G.) UNIT SIZES 0611, 0811, 1011 (IN.W.G.)
1.0- "0
0.9- 0.9
0.8- 0.8
0.7- 03
0.6- 0.6
05- 0.5
0.4- 0.4
0.3- 0.3
0.2- 0.2-
0.1- 0.1-
0.04 0.0
150 300 450 600 750 900 700 Boo 900 1000 1100 1200 1300 1400
AIRFLOW/CFM(Standard Density Air) AIRFLOW/CFM(Standard Density Air)
E.S.P. UNIT SIZES 1021,1221,1421 E.S.P. UNIT SIZES 1224,1424
(IN.W.G.) (IN.W.G.)
1.0 1.0-
.9- 0.9
0.8- 0.8
0.7- 0.7
0.6- 0.6-
0.5- 0.5-
0.4- 0.4-
0.3- 0.3-
0.2- 0.2-
0.1- 0.1-
0.0- 0.0-
1200 1400 1600 1800 2000 1400 1600 1800 2000 2200 2400
AIRFLOW CFM(Standard Density Air) AIRFLOW/CFM�Standard Density Air)
ENVIRO-TEC 19
Q ENVIRO-TECO
CFRQ ELECTRIc HEAT .1$1 r
BY JOHNSON CONTROLS
Model CFRQ-EH
Standard Features IMSelection Procedure
- cETL Listed as an assembly for safety compliance With standard heater elements,the maximum capacity(KW)
per UL 1995 is obtained by dividing the heating (fan) SUM by 70. In
- Primary auto-reset high limit other words,the terminal must have at least 70 SUM per
- Secondary high limit KW. In addition,each size terminal has a maximum allow-
- Hinged control panel able KW based upon the specific heater element configuration
- Ni-Chrome elements (i.e. voltage, phase, number of steps, etc.). Contact your
- Primary/secondary power terminations ENVIRO-TECI representative or refer to the ENVIRO-TEC'
- Fusing per NEC Windows' based computer selection program for design
- Wiring diagram and ETL label assistance.
- Fan interlock device (relay or RE. switch)
- Single point power connection Heaters require a minimum of 0.07"w.g. downstream sta-
- Available kW increments are as follows: tic pressure to ensure proper operation,
0.5 to 5.0 kW - .25 kW; 5.0 to 10.0 kW - .50 kW; For optimum diffuser performance in overhead heating
Above 10 kW - 1.0 kW. applications, the supply air temperature should be with-
Optional Features in 20'F of the desired space temperature. This typically
• Disconnect (toggle or door interlocking) requires a higher air capacity which provides higher air
• P.E. switches motion in the space increasing thermal comfort. The elec-
• Mercury and magnetic contactors tric heater should be selected with this in mind, keeping
• Manual reset secondary limit the LAT as low as possible.
• Proportional control (SSR) Selection Equations
• 24 volt control transformer kW = SUM x AT L( 1.085*
• Airflow switch 3413
Maximum Allowable kW CFM kW x 3413
AT x 1.085*
�NIT SIZE �� MAX CFM MAX Wd
0606,0611 550 7 AT kW x 3413
0806 700 10 SUM x 1.085*
0811,0817,0819 1000 14 Air density at sea level- reduce by 0.036
1011 1200 17 for each 1000 feet of altitude above sea level.
1017,1019,1021 1600 20 Calculating Line Amperage
1217,1219,1221 1800 20 Single Phase Amps kW x 1000
1224 2000 20 Volts
1421 2000 25
1424 2400 25 Three Phase Amps kW x 1000
1230 2300 2 Volts x 1.73
1430,1630 3100 30
20 Johnson Controls
T
,,,41 ErwIRO.TEC"'
m FAN MOTOR OPTION CFRQ
ECM
BY JOHNSON CONTROLS
volume can be field calibrated in two fashions. First, a
The Energy Efficient Solution
potentiometer is provided allowing manual adjustment
ENVIRO-TEC" offers an alternative to the PSC motor using an instrument type screwdriver. In addition, the
that significantly increases theoperating efficiencyof fan volume can be calibrated through the BMS using an
fan terminal units. This motor is frequently referred to analog output (2 to 1OVDC typical) to the speed
as an ECMT" (electronically commutated motor). It is a controller. A fan volume verses DC volts calibration chart
brushless DC (BLDC) motor utilizing a permanent mag- is provided.
net rotor. The motor has been in production for years
and is commonly used in residential HVAC units. Fan speed Designer/ Owner Flexibility
control is accomplished through a microprocessor based The ECIVI' incorporates ball bearings in lieu of sleeve
variable speed controller(inverter) integral to the motor. bearings typically utilized with an induction
The motor provides peak efficiency ratings between 70 motor. Unlike a sleeve bearing
& 80%for most applications. motor, the ECMT" does not have
a minimum RPM requirementfror
ECMTm FEATURES AND BENEFITS bearing lubrication. This allows
Ultra-High Motor & Controller Energy Efficiency it to operate over a much
DC motors are significantly more efficient than AC wider speed range. One
motors. At full load the ECMT" is typically 20%more eff i- motor can handle the
cient than a standard induction motor. Due to acoustical capacity range previ-
considerations, the fan motor on a fan powered termi- ously handled by two
nal typically operates considerably less than full load. At motors, allowing sim-
this condition the overall motor/controller(SCR)efficiency
plification of the
can be cut in half. Due to the permanent magnet, DC product line and con-
design,the ECM T"
maintains a high efficiency at low speeds. siderable flexibility to the
Most fan powered unit selections will have an overall effi- designer. The owner also
ciency greater than 75%. Furthermore, the motor heat benefits since equipment
gain is greatly reduced providing additional energy sav- changes are much less likely with tenant requirement
ings by reducing the cold primary air requirement. changes. A reduced spare parts inventory is another plus.
Pressure Independent Fan Volume Custom Applications—
The integral microprocessor based controller includes a Programmable Fan Operation
feature that provides sensorless(no external feedback)con- Boundless control opportunities arise due to the con-
stant airflow operation by automatically adjusting the speed trollability of a DC motor combined with an integral
and torque in response to system pressure changes. This microprocessor. Various input signals can direct the motor
breakthrough will no doubt have far reaching to behave in an application specific mode. For instance,
benefits and endless applications. For starters, the fan multiple discrete fan capacities can be achieved. In
volume supplied to the space will not significantly change addition, the fan speed can be varied in response to the
as a filter becomes loaded. This provides new opportu- space temperature load. The fan can also be pro-
nities for medical applications where space pressurization grammed for a soft start. The motorstarts ata very low
and HEPA filters are applied. The air balance process will speed and slowly ramps up to the required speed. This
become simpler and more accurate since the fan volume is especially beneficial for parallel flow fan terminals since
will not need to be re-adjusted after the diffuser balance the perceived change in space sound levels is lessened.
is accomplished.
Extended Motor Life
Factory Calibrated Fan Volume The high motor efficiency provides a significantly reduced
Due to the pressure independent feature, the fan operating temperature compared to an induction motor.
capacity can now be calibrated at the factory. Within the The lower temperature increases the longevity of all
published external pressure limits, the fan motor will electrical components and therefore the life of the motor.
automatically adjust to account for the varying static The ball bearings do not require lubrication and do not
pressure requirements associated with different adversely impact the motor life. Most fan powered
downstream duct configurations. This feature should not applications will provide a motor life between 60,000 and
preclude the final field air balance verification process 100,000 hours. A motor life of twenty five years will not
during the commissioning stage of a project. An 10P
be uncommon for a series flow fan terminal and a long
electronic(PWM)speed control device is provided to allow life can be expected for a parallel flow unit.
field changes of the fan capacity as the need arises. Fan
Johnson Controls 17
PRIMARY AIR
INLET SIZE
9000 SIZE 22
800.0 SIZE 19
7000-
6000
500q SIZE 18
SIZE 16
400.0
SIZE 14
3000
2500 SIZE 12
20GO
SIZE 10
1500
1000
SIZE 8
goo
800
:2 700
LL.
C) 600
SIZE 6
3�: 5GQL SIZE 5
0
__j
LL_ 400
30.0 SIZE 4
25.0
200
15 0
14:f
100
7Q
50
41-9
39
.Oi5 o�o o�5 .63 .64 .65 .66 .67.68.69 1 i5 .�O .�5 k .40 .�O .60 .�0.60.60 1'.5
.10 1.0
A P ACROSS PROBE (inches w.g.)
For optimum control accuracy, a straight section of duct at least 1.5 duct diameters long and the same diameter as the
inlet collar should be installed upstream of the terminal inlet. Sizes 6 through 22 utilize FlowstarTm multi—axis center averaging sensor;
Sizes 4 and 5 utilize single—axis, linear averaging multi—point sensor.
ENVIRO- TEC@ SUBMITTAL DATA
MODEL SDR, E)E)R, "1 1, FC FR, C FRQ], DRAM BY., DATE:
P)Tw, N F—P?, AWW 20 NOV 92
WITH ENVIRO-TEC(" ELECTRONIC CONTROLS RE1110: 02 REV DATE.- 20 JUN 97
A P vs CFM @ INLET I APPROVED BY: S.P.I DRAWNG NO: 15883
15780
DAIKIN
AHU-1
SUBMITTAL DATA
for
1010 Bldg HVAC Upgrades
Sold to
Crescent Mechanical
Prepared for
Rice Group
Job Number: FSJ13B Customer PO#:
Prepared by
Norby Company
Jim Pechan
425-828-6636
12/19/2014
Job Number: FSJ13B Page Prepared Date: 12/19/2014
Job Name: 1010 Bldg HVAC Upgrades 1 of 8 www.DaikinApplied.com
or
Table of Contents
TechnicalData Sheet for AHU-1 .................................................................................................................................................3
MPS040-050A Cooling only_Drawing for AHU-1.........................................................................................................................6
MPS 040-050 Cooling Curb_Drawing for AHU-1........................................................................................................................7
Job Number: FSJ13B Page Prepared Date: 12/19/2014
Job Name: 1010 Bldg HVAC Upgrades 2 of 8 www.DaikinApplied.com
N
Technical Data Sheet for AHU-1
JobInformation k JAI
Job Name 1010 Bldg HVAC Upgrades
Date 12/17/2014
Submitted By Jim Pechan
Software Version
Unit Tag AHU-1
Unit Overview
Model Number Itage Design Cooling R AHRI 360 Sta�nndaard
I Capacity Efficiency
MPS040F 460/60/3 493992 Btu/hr 10.1 13 2010 Compliant
Model Number: MPS040F
Model Type: Cooling,Standard Efficiency
Heat Type: None
Application: Variable volume, w/VFD, Duct Pressure Control
Altitude: 0 ft
Approval cETLus
Physical
Unit Dimensions and Weights
Unit Length Unit Height Unit Width Unit Weight
245.5 in 73.2 in 97.5 in 4940 lb
Unit Construction
Exterior: Prepainted Galv Steel Doors: Fan, Filter, Control Panel, and Gas Heat
section
Insulation: R-value of 4.0 Drain Pan Material Stainless Steel
Liners: Double wall construction
Unit Electrical Data
Voltage SCCR MCA MROPD
460/60/3 v 10 kAIC 89.7 A 100A
Return/Outside/Exhaust Air
Outside Air Option
Type Damper Damper Pressure Drop Leakage Rate
0-30%outside air with 2 Low leak with blade and jamb 0.05 inH20 3 cfm/sq ft @1" differential
position damper seals pressure
Ventilation Control: None
Draw Through Filters
Efficiency Quantity/Size Face Area ft' Face Velocity ft/min Air Pressure Drop inH�O
30%MERV 8 8 24 in x 24 in x 2 in, 36.0 444 0.15
4 18 in x 24 in x 2 in
Job Number: FSJ13B Page Prepared Date: 12/19/2014
Job Name: 1010 Bldg HVAC Upgrades 3 of 8 www.DaikinApplied.com
Technical Data Sheet for AHU-1
Cooling Colt
Fins per Inch Rows Face Area Face Velocity Air Pressure drop
ft2 ft/min inH20
12 4 35.7 448 0.44
Cooling Performance
Total Capacity Sensible Capacity Entering Air Temperature Leaving Air Temperature Ambient Air Temp
Btu/hr Btu/hr Dry Bulb Wet Bulb Dry Bulb Wet Bulb -F
-F -F -F -F
493992 383769 80.0 67.0 58.1 57.2 95.0
Fan Section
Type Fan Wheel Diameter Vibration Isolation
AF SWSI 30in 1 inch spring, seismic
Fan Performance
Air Flow Total Static Pressure Fan Speed Brake Horsepower Altitude
16000CFM 2.14 inl-120 1251 RPM 9.1 HP 0 ft
Motor
Horsepower Type Efficiency Full Load Current
10 HP Open drip proof, Premium 91.7 13.0 A
efficiency
Drives
Type Service Factor
Belt Drive 120%
Condensing Section
Compressor
Type Quantity Total Power Capacity Control Refrigerant Type
Scroll 4 37.2 kW 5 steps R410A
Compressor Amps:
Compressor I 18.6A
Compressor 2 18.6A
Compressor 3 13.1 A
Compressor 4 13.1 A
Condenser Coil
Type Fins Per Inch Rows Fin Material Refrigerant Valves
Aluminum tube micro 18 Micro Channel Aluminum None
channel
Condenser Fan Motors
Number of Motors Full Load Current
4 2.OA
AHRI 360 Certified Data at AHRI 360 Standard Conditions
Net Capacity Efficiency ASHRAE 90.1
439000 Btu/hr 10.1 EER 13 1EER 2010 Compliant
Internal Static Pressure Drop Calculation
External Static Pressure: 1.50
Outside Air Damper: 0.05
Filter: 0.15
Cooling Coil: 0.44
Total Static Pressure: 2.14 in H2O
Job Number: FSJ13B Page Prepared Date: 12/19/2014
Job Name: 1010 Bldg HVAC Upgrades 4 of 8 www.DaikinApplied.com
Technical Data Sheet for AHU-1
Sound Power
Inlet
63 Hz 125 Hz 250 Hz 500 Hz 1 kHz 2 kHz 4 kHz 8 kHz
75 78 85 77 73 68 66 63
Outlet
63 Hz 125 Hz 250 Hz 500 Hz 1 kHz 2 kHz 4 kHz 8 kHz
81 85 90 86 82 77 73 69
Radiated
63 Hz 125 Hz 250 Hz 500 Hz 1 kHz 2 kHz 4 kHz 8 kHz
84 94 92 91 88 86 84 83
Electrical
Field Connection: Power Block, Field powered 115V GFI outlet
Power Options: Phase Failure
Controls
Temperature Controls: DDC controls,field installed BACnet/IP card
Warranty
Parts Warranty: Standard one year
Compressor Warranty: Standard one year
AHRI Certification
All equipment is rated and certified in accordance with AHRI 340/360
As a standalone component, unit meets or exceeds the requirements of ASHRAE 90.1.2010. The approving authority is
responsible for compliance of multi-component building systems.
Accessories
Part Number Description
090016709 MT III Com Mod for Applied Rooftops, BACnet IP
Job Number: FSJ13B Page Prepared Date: 12/19/2014
Job Name: 1010 Bldg HVAC Upgrades 5 of 8 www.DaikinApplied.com
MPS040-050A Cooling only_Drawing for AHU-1
Condensate
Drain Side
60.50(1537 mm)From Corner 97.50
5.00(127 mm)From Bottom (2476 mm)
Plenum
Fan Access
Filter/Coil Access 72.88
(1851 mm)
Optional Exhaust
Hood
245.50
(6236 mm)
OA Hood From
Bottom of Unit
31.00(787 mm)
(Optional)
Electric Heat Access
Control Panel
Filter/Coil Access
Return Access
Z',-- 71 M
'Af (1803 mm)
4W..,.;.,Supply Opening
Optional 28.00
Hot Water 5.00 (711 mm)
Chase 60.50 (127 mm) 75.12 Supply Opening
(1905 mm)
(1544 mm)
86.75 Condensate Drain
(2203 mm) ell 30.25
(772 mm)
Return Opening Z�IXZZ5-38 Return Opening
(137 mm) 5.38
(137 mm)
pr�ur
Product Drawing Unit Tag:AHU-1 , DAIKIN
Product: Project Name:1010 Bldg HVAC Upgrades 13600 Industrial Park Blvd.Minneapolis,IVIN 55441
Model:MPS040F Sales Office:Norby Company(Seattle) www.DaikinApplied.com Software Version:04.50
sJn[mm]
Sales Engineer: Dec.19,2014 1 Ver/Rev:, Sheet 1 of 1 Scal,.NTS I T.1e,.nce:+/-0.25� Dwg Units�
No change to this drawing may be made unless approved in writing by Daikin Applied. Purchaser must determine that the equipment is fit and sufficient for the job
specifications.
Job Number: FSJ13B Page Prepared Date: 12/19/2014
Job Name: 1010 Bldg HVAC Upgrades 6 of 8 www.DaikinApplied.com
MPS 040 -050 Cooling Curb_Drawing for AHU-1
200
151 mnn� 30.W 28,25
[778 mm) (718 mm]
2.00
(51 rrim]
SA 71.38
OPNG [1813mm]
87.25 RA
12216 mm] OPNG
(INSIDE CURB)
15.87
2.00 ji too (403 mm)
4---
T 1.63]
69.39 141 mm]
[1763 mml 105.45
[2678 mm)
208.57(INSIDE CURB)
15298 mm]
PLAN VIEW
(a) Unit Base
Curb Gasketing
2.00 2X4 Nailer Strip
(51 mrn] Galvanized Curb
0300
KNOCKOUT N Can't Strip(M furnished)
1.00 (2) Roofing Material(not fumished)
5 0.88
Ridgid Insulation(not furnished)
KNOCKOUT 3,75 AL
(4) 195 ni 2.28 Counter flashing(not furnished)
Ductwork(not furnished)
_Z00
151 rnml
28,92
[735 mm) Z)
KNOCKOUT DETAIL
CURB CROSS SECTION
ProductDrawing Unit Tag:AHU-1 DAIKIN
Product: Project Name:1010 Bldg HVAC Upgrades 13600 Industrial Park Blvd.Minneapolis,MIN 55441
Model:MPS040F Sales Office:Norby Company(Seattle) www.D k A I d-co Software Version:04.50
al InA
Sales Engineer: Dec.19,2014 1 Ver/Rev: Sheet 1 of I Scale:NTS ["Toleearancee:+/-0.25"1 Dwg Units:in[mm]
No change to this drawing may be made unless approved in writing by Daikin Applied. Purchaser must determine that the equipment is fit and sufficient forthejob
specifications.
Job Number: FSJ13B Page Prepared Date: 12/19/2014
Job Name: 1010 Bldg HVAC Upgrades 7 of 8 www.DaikinApplied.com
Address:
12140 W 18 th Street Bldg 1030
PREPARED 6/24/16, 8:29:12 INSPECTION TICKET PAGE) 7
CITY OF PORT ANGELES INSPECTOR: JAMES LIERLY DATE 6./24/16
------------------------------------------------------------------------------------------------
ADDRESS 2140 BLDG 1030 W 18TH ST SUBDIV:
CONTRACTOR STRAIT COMFORT SYSTEMS PHONE (360) 440-8539
OWNER PORT OF PORT ANGELES PHONE (360) 457-8527
PARCEL 06-30-00-1-1-2100-5001-
APPL NUMBER: 16-00000813 COMM MECHANICAL PERMIT
------------------------------------------------------------------------------------------------
PERMIT: ME 00 MECHANICAL PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
ME99 01 6/24/16 JkL MECHANICAL FINAL
June 24, 2016 8:28:30 AM jlierly.
Richard
-------------------------------------- COMMENTS AND NOTES ------------------J—----------- -------
CITY OF PORT ANGELES
hz'mft7a'�
DEPARTMENT OF COMMUNITY 8r- ECONOMIC DEVELOPMENT- BUILDING DIVISION
321 EAST 5TH STREET, PORT ANGELES, WA 98362
Application Number . . . . . 16-00000813 Date 6/07/16
Application pin number . . . 351339
Property Address . . . . . . 2140 BLDG 1030 W 18TH ST
ASSESSOR PARCEL NUMBER: 06-30-00-1-1-2100-5001- REPORT SALES TAX
Application type description COMM MECHANICAL PERMIT on your state excise,tax.fonn.-
Subdivision Name . . . . . .
Property Use . . . . . . . . to the City of Port Ahoeles
Property Zoning . . . . . . . INDUSTRIAL LIGHT (Location Cod� 0�0
Application valuation . . . . 2)
4335
----------------------------------------------------------------------------
Application desc
-t�' Ductless heat pump
-------------------------------------------------------------------------
Owner Contractor
------------------------ ------------------------
PORT OF PORT ANGELES STRAIT COMFORT SYSTEMS
PO BOX 1350 235546 HIGHWAY 101
PORT ANGELES WA 983620251 PORT ANGELES WA 98363
(360) 457-8527 (360) 440-8539
C/') -----------------------------------------------------------------------------
Permit . . . . . . MECHANICAL PERMIT
Additional desc . . DUCTLESS HP
Permit Fee . . . . 64.80 Plan Check Fee .00
Date . . . . 6/07/16 valuation . . . . 0
Expiration Date 12/04/16
Qty Unit Charge Per Extension
BASE FEE 50.00
1.00 14.8000 EA ME-FURN/HP/FAU < OR 5 TON 14.80
---- ------- -- -------------- - -- - - --- -----
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 64.80 64.80 .00 .00
Plan Check Total .00 .00 .00 .00
Grand Total 64.80 64.80 .00 .00
Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes
null and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned
for a period of 180 days after the work has commenced,or if required inspections have not been requested within 180 days from th.e
last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions
of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit..does
not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construction.
Date Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder)
T:Forms/Building Division/Building Permft
BUILDING PERMIT INSPECTION RECORD
PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS—
Building Inspections 417-4815 Electrical Inspections 417-4735
Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886
IT IS UNLAWFUL TO COVER,INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED.
POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE.
Inspection Type Date Accepted By Comments
FOUNDATION:
Footings
Stemwall
Foundation Drainage/Downspouts
Piers
Post Holes(Pole Bldgs.)
PLUMBING:
Under Floor/Slab
Rough-In
Water Line(Meter to Bldg)
Gas Line
Back Flow/Water
AIR SEAL:
Walls
Ceiling
FRAMING:
Joists/Girders/Under Floor i
Shear Wall/Hold Downs
Walls/Roof/Ceiling
Drywall(Interior Braced Panel Only)
T-Bar
INSULATION:
Slab
Wall/Floor I Ceiling
MECHANICAL:
Heat Pump/Fumace/FAU/Ducts
Rough-In
Gas Line
Wood Stove I Pellet/Chimney
Commercial Hood I Ducts
MANUFACTURED HOMES:
Footing/Slab
Blocking&Hold Downs
iSkirting
PLANNING DEPT. Separate Permit#s SEPA:
Parking/Lighti g ESA:
Landscaping ISHORELINE:
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY1 USE
Inspection Type Date Accepted By
Electrical 417-4735
Construction -R.W. PW I Engineering 417-4831
Fire 417-4653
Planning 417-4750
I Building 417-4815
THE
For City We
CATY
or
Ap
Permit#
W A S H I N G T 0 N, U . S. Date Received: W
321 E 51h Street te Approved 6n 26
Port Angeles,WA 9836
P:360-417-4817 F:360-417-4711
Email:permits C@cityofpa.us PLIC
BUILDING PERMIIWAPPLICATION
Project Address: �_t j-g a;�H �F
Phone: qT2 -C77C
Primary Contact: cowvS'/r F&_8oawC_t6J-t'vc Email:
Name Phone
PONF of-
Property Mailing Address Email
Owner
city State zip
POILF V-1011111ft
Name Phone
5TA&T- 52�ET'C-1"r
Contractor Address Email
?_?4_5'Y6 W 1-t
Information -city po�l_ A-V-"-t'AS State Zip
Contractor License# '5'1-'Z'q I C-5� 6 r Z_ L T Exp.Date: 2-017
Legal Description: Zoning: Tax Parcel# Project Value: (materials and labor)
$
Residential 11 Commercial 11 Industrial 11 Public 11
Permit Demolition El Fire El Repair 11 Reroof(tear off/lay over)
Classification For the following,fill out both pages of permit application:
(check New Construction El Exterior Remodel El Addition 11 Tenant improvement
appropriate) Mechanical 11 Plumbing 11 Other El
Fire Sprinkler System Proposed Irrigation System Proposed or Proposed Bathr roposed Bedrooms
.or Existing? Yes 0 No 0 1 Existing? Yes 0 No E3 I
In addition to standard hard copy submittals please send a PDF copy of all Stormwater plans and Engineering to
www.stormwater(&cityo a.us
Project.Description J01/c,7144S!P HE4T Prmlf 1/-' -`414Ea P,�-
Is project in a Flood Zone: Yes 0 NoE3 Flood Zone Type:
If in a Flood Zone,what is the value of the structure before proposed improvement? $
1 have read and completed the application and know it to be true and correct.I am authorized to apply for
this permit and understand that it is my responsibility to determine what permits are required and to
obtain permits prior to work. I understand that plan review fees are not refundable after review has
occurred. I understand that I will forfeit review fees if I withdraw the application before the permit is
issued. I understand that if the permit is not picked up/issued within iAo days of submittal,the application
will be considered abandoned and the fees will be forfeited.
Date er,,oC/,,?/,w/a Print Name Ric-il,41W F IFE Signature /(z&,,
Residential Structures
Existing Proposed Construction For Office Use
Area Descriptions(SQ FT) Floor area Floor area $Value new area
Basement
First Floor
Second Floor
Covered Deck/Porch/Entry
Deck(over 30"or 2'd floor)
Garage
Carport
Other(describe)
Area Totals
Commercial Structures
Area Descriptions(SQ FT) Existing Proposed Construction For Office Use
Floor area Floor area $Value new area
Existing Structure(s)
Proposed Addition
Tenant Improvement?
Other work(describe)
Site Area Totals
Lot/Site Coverage Calculations
Lot Size (sq ft) Lot Coverage(sq ft)foot print of %Lot Coverage(Total lot cov lot size) Max Bldg Height
I all structures sq ft
Site Coverage(Sq Ft of all impervious) %of Site Coverage(total site cov--. lot size)
Mechanical Fixtures
Indicate how many of each type of fixture to be installed or relocated as part of this project.
Air Handler I Size: # Haz/Non-Haz Piping Outlets:
Appliance Exhaust Fan # Heater(Suspended,Floor,Recessed wall) #
Boiler/Compressor Size: # Heating/Cooling appliance #
I repair/alteration
Evaporative Cooler(attached,not # Pellet Stove/Wood-burning/Gas #
portable) Fireplace/Gas Stove/Gas Cook Stove/Misc.
Fuel Gas Piping #of Outlets: Ventilation Fan,single duct #
Furnace/Heat Pump/ Size: # Ventilation System #
Forced Air Unit I I I
Plumbing Fixtures
Indicate how many of each type of fixtu e to be installed or relocated
Plumbing Traps # Water Heater #
Plumbing Vent piping # Medical gas piping #of Outlets:
Wa ter Line # Fuel gas piping #of Outlets:
Sewer Line # Industrial waste pretreatment
interceptor(Grease Trap) Size
Other(describe):
T:\Forms\2015 CED Form Updates\Building&Permitting\BP\Building Permit 2015041S.docx