PREPARED 5/2S/16, 8:20:49 INSPECTION TICKET PAGE 13
CITY OF PORT ANGELES INSPECTOR: JAMES LIERLY DATE 5/2S/16
------------------------------------------------------------------------------------------------
ADDRESS . : 2301 W 16TH ST SUBDIV:
CONTRACTOR : PHONE :
OWNER CHRISTINA WONSEY/ ROBERT WHITE PHONE : (360) 452-6796
PARCEL 06-30-01-8-6-0150-0000-
APPL NUMBER: 1S-00000417 RES NEW SFR
------------------------------------------------------------------------------------------------
PERMIT: BPR 00 BUILDING PERMIT - RESIDENTIAL
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
BL1 01 6/26/15 PB BLDG FOUNDATION FOOTING
G/26/15 AP June 26, 2015 9:01:49 AM pbarthol.
June 29, 2015 8:33:51 AM pbarthol.
BL2 01 7/06/15 JLL BLDG FOUNDATION STEM WALL
7/06/15 AP July G, 2015 9:15:41 AM jlierly.
Bruce
July 6, 2015 4:1S:32 PM jlierly.
BLFD 01 7/17/15 JLL BLDG FOUNDATION DRAINAGE
,7/17/15 AP July 17, 2015 8:59:50 AM jlierly.
July 17, 2015 4:15:47 PM jlierly.
BFF 01 7/23/15 JLL BLDG FLOOR FRAMING
7/24/15 AP July 23, 2015 9:32:18 AM jlierly.
Bruce 912-0079
July 24, 2015 9:39:52 AM jlierly.
BEXS 01 9/09/15 JLL BLDG EXTERIOR SHEETING
9/09/15 AP September 9, 2015 10:29:40 AM jlierly.
mike 775-8601
September 9, 2015 4:16:52 PM jlierly.
BAIR 01 12/17/15 JLL BLDG AIR SEAL
12/17/15 AP December 17, 201S 10:09:25 AM jlierly.
Bruce 912-0079
December 17, 2015 4:08:16 PM jlierly.
BL3 01 12/17/15 JLL BLDG FRAMING
12/17/15 AP December 17, 2015 10:09:49 AM jlierly.
December 17, 2015 4:08:16 PM jlierly.
BLI 01 12/23/15 JLL BLDG INSULATION
1/04/16 AP December 23, 2015 9:10:16 AM jlierly.
��V January 4, 201G 4:22:40 PM jlierly.
BL99 01 5/25/16 BLDG FINAL
May 24, 2016 12:24:27 PM jlierly.
Bruce 912-0057
-------------------------%- ----------------------------------------------------------------------
PERMIT: ME 00 MECHANICAL PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
ME99 01 5/25/16 MECHANICAL FINAL
May 24, 201G 12:25:01 PM jlierly
------------------- -- --- ---- -------- -- --------
PERMIT: PL 00 PLUMBING-I&W-.-IT-
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
PL6 01 7/15/15 JLL PLUMBING WATER SUPPLY
7/15/15 AP July 15, 2015 10:16:49 AM jlierly.
bruce 912-0079
----------------------------------- CONTINUED ONTO NEXT PAGE -----------------------------------
CITY OF PORT ANGELES
DEPARTMENT OF COMMUNITY & ECONOMIC DEVELOPMENT- BUILDING DIVISION
321 EAST 5TH STREET, PORT ANGELES, WA 98362
Application pin number . . . 223131
Application Number . . . . . 15-00000417 Date 5/08/15
Property Address . . . . . . 2301 W 16TH ST
ASSESSOR PARCEL NUMBER: 06-30-01-8-6-0150-0000- REPORT SALES TAX
Application type description RES NEW SFR on your state excise tax form
Subdivision Name . . . . . .
Property Use . . . . . . . . to the City of Port Angeles
Property Zoning . . . . . . . RS9 RESDNTL SINGLE FAMILY
Application valuation 112868 (Location Code 0502)
----------- --------- - - - - ------
Application desc
1196sf SFR W/84 PORCH, 340 GARAGE 3BD 2BTH
----------------------------------------------------------------------------
Owner Contractor
------------------------ ------------------------
CHRISTINA WONSEY/ ROBERT WHITE OWNER
2301 W 16TH ST
PORT ANGELES WA 98363
(360) 452-6796
-------------------------------- -------------------------------------------
Permit . . . . . . BUILDING PERMIT -RESIDENTIAL
Additional desc . . 1620SF 1 STRY SFR 3BD 2BTH
Permit Fee . . . . 1093.05 Plan Check Fee 710.48
Issue Date . . . . 5/08/15 Valuation . . . . 112868
Expiration Date 11/04/15
Qty Unit Charge Per Extension
BASE FEE .1020.25
13.00 S.6000 THOU BL-100,001-500K (5.60 PER K) 72.80
----------------------------------------------------------------------------
Permit . . . . . . MECHANICAL PERMIT
Additional desc . . SFR MECHANICAL
Permit Fee . . . . 141.60 Plan Check Fee .00
Issue Date . . . . 5/08/15 Valuation . . . . 0
Expiration Date . , 11/04/15
Qty Unit Charge Per Extension
BASE FEE 50.00
1.00 14.8000 EA ME-FURN/HP/FAU < OR = 5 TON 14.80
3.00 7.2SOO EA ME-VENT FAN (SINGLE DUCT) 21.75
1.00 10.G500 EA ME-HOOD/DUCT-M ECH. EXHAUST 10.65
3.00 14.8000 EA ME-HEATER(SUSP/WALL/FLOOR-MTD) 44.40
----------------------------------------------------------------------------
Permit . . . . . . PLUMBING PERMIT
Additional desc . . SFR PLUMBING
Permit Fee . . . . 135.00 Plan Check Fee .00
Issue Date *. . . . 5/08/15 Valuation . . . . 0
Expiration Date . . 11/04/15
Qty Unit Charge Per Extension
BASE FEE . 50.00
S.00 7.0000 EA PL-PLUMBING TRAP 35.00
1.00 7.0000 EA PL-WATER LINE 7.00
3.00 7.0000 EA PL-DRAIN VENT PIPING 21.00
Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. Thispermitbecorn es
null and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned
for a period of 180 days after the work has commenced, or if required inspections have not been requested within 180 days from the
last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions
of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does
not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construction.
16 ell /Szu el!�Wl-iLj
Date Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder)
T:Form s/Building Division/Building Permit
BUILDING PERMIT INSPECTION RECORD
— PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS—
Building Inspections 417-4815 Electrical Inspections 417-4735
Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886
IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED.
POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE.
Inspection Type Date Accepted By Comments
FOUNDATION:
Footings
Sternwall
Foundation Drainage/Downspouts
Piers
Post Holes(Pole BIdgs.)
PLUMBING:
Under Floor/Slab
Rough-in
Water Line(Meter to Bldg)
Gas Line
Back Flow/Water FINAL Date Accepted by
AIR SEAL:
Walls
Ceiling
FRAMING:
Joists/Girders/Under Floor
Shear Wall/Hold Downs
Walls/Roof/Ceiling
Drywall(Interior Braced Panel Only)
T-Bar
INSULATION:
Slab
Wall/Floor/Ceiling
MECHANICAL:
Heat Pump/Furnace/FAU/Ducts
Rough-In
Gas Line
Wood Stove/Pellet/Chimney
Commercial Hood I Ducts FINAL Date Accepted by
MANUFACTURED HOMES:
Footing/Slab
Blocking&Hold Downs
Skirting
PLANNING DEPT. Separate Permit#s SEPA:
Parking/Lighting ESA:
Landscaping ISHORELINE:
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY1 USE
Inspection Type Date Accepted By
Electrical 417-4735
Construction- R.W. PW /Engineering 417-4831
Fire 417-4653
Planning 417-4750
L Building 417-4815
T:Forms/Building Division/Building Permit
CITY OF PORT ANGELES
DEPARTMENT OF COMMUNITY & ECONOMIC DEVELOPMENT- BUILDING DIVISION
321 EAST 5TH STREET, PORT ANGELES, WA 98362
Page 2
Application Number . . . . . 15-00000417 Date 5/08/15
Application pin number . . . 223131 REPORT SALES TAX
Qty Unit Charge Per Extension on your state excise tax form
1.00 15,0000 EA PL-SEWER LINE 15.00
1.00 7.0000 EA PL-WATER HEATER 7.00 to the City of Port Angeles
------- ----- --- --------
-----Special-Notes-and-Comments---------------------- ----------------------- (Location Code 0502)
Address numbers shall be plainly visible from the street.
Address numbers shall be a minimum of six inches high and be
of contrasting color from the background.
All homes in new subdivisions that are outside of the Fire
Department four-minute response area shall be equipped with
residential fire sprinkler systems that comply with the
International Fire Code (IFC) and National Fire Protection
Association (NFPA) .
Electrical load calculations and electrical permits are
required.
Ditches & 1211 culverts will. be installed to City Stanards.
See Public Works Engineering for Standards.
1) Standard Stormwater Comments for temporary erosion
control. This is part of a larger plan of development,
greater than 1 acre.
This includes
1. Mark Clearing Limits
2. Establishing Construction Access
3. Control Flow Rates
4. Install sediment controls BMPs.
5. Stabilize exposed soils
6. Protect slopes from erosion
7. Protect drain inlets
8. Control pollutants including but not limited to spills,
concrete wash out, exposed aggregate processes, concrete
grinding and saw cut waste water. A marked contained .
concrete washout area is required may not discharge truck
wash water to sewer, ditches or ground.
9. Maintain temporary and permanent erosion control BMPS
during project
10. Update TESC plans as changes take place
No downspouts shall be connected to sanitarysewer.
Also include: Consider applying for the C ity Green
Infrastructure Rebate of up to $750 towards the materials to
install a rain garden to control roof or driveway runoff.
Separate Right of Way Construction permit required for
driveway and culverts.
Trench safety per applicable laws. Temp erosion control and
surface restoration responsibility of applicant. Contact
City inspector prior to start of work @ 360 417-4831. No
attachment to sanitary sewer of stormwater roof leaders,
foundation drains, yard drains, or any other CSO
contribution is allowed.
Sanitary sewer connection inspection is required by
Public Works prior to back fill of ditch. 24 hour advance
notice is required. Public Works Inspection request line
Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes
null and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned
for a period of 180 days after the work has commenced, or if required inspections have not been requested within 180 days from the
last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions
of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does
not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construction.
Date Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder)
T:Forms/Building Division/Building Permit
BUILDING PERMIT INSPECTION RECORD
— PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS—
Building Inspections 417-4815 Electrical Inspections 417-4735
Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886
IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED.
POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE.
Inspection Type Date Accepted By Comments
FOUNDATION:
Footings
Stemwall
Foundation Drainage/Downspouts
Piers
Post Holes(Pole Bldgs.)
PLUMBING:
Under Floor/Slab
Rough-in
Water Line(Meter to Bldg)
Gas Line
Back Flow/Water FINAL Date Accepted bV
AIR SEAL:
Walls
Ceiling
FRAMING:
Joists/Girders/Under Floor
Shear Wall/Hold Downs
Walls/Roof/Ceiling
Drywall(Interior Braced Panel On]yL_
T-Bar
INSULATION:
Slab
Wall/Floor/Ceiling
MECHANICAL:
Heat Pump/Furnace/FAU/Ducts
Rough-In
Gas Line
Wood Stove/Pellet/Chimney
Commercial Hood/Ducts FINAL Date Accepted by
MANUFACTURED HOMES:
Footing/Slab
Blocking&Hold Downs
,Skirting
PLANNING DEPT. Separate Permit#s SEPA:
Parking/Lighting ESA:
Landscaping ISHORELINE:
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY1 USE
Inspection Type Date Accepted By
Electrical 417-4735
Construction- R.W. PW /Engineering 417-4831
Fire 417-4653
I Planning 417-4750
1 Building 417-4815
T:Forms/Building Division/Building Permit
CITY OF PORT ANGELES
DEPARTMENT OF COMMUNITY& ECONOMIC DEVELOPMENT- BUILDING DIVISION
321 EAST 5TH STREET, PORT ANGELES, WA 98362
Page 3
Application Number . . . . . 15-00000417 Date 5/08/15
Application pin number . . . 223131
---------------------------------------------------------------------------- REPORT SALES TAX
Special Notes and Comments on your state excise tax,form
417-4831
The contractor making the connection to an existing water to the City of Port Angeles
meter is responsible to adjust water meter depth so that (Location Code 0502)
there is a minimum of 4 to G inches of clearance between the
bottom of the meter box lid and the top of the meter at
finish grade.
Construct driveway to City Standards. Concrete with exposed
aggregate or other non-standard finishes(including colors or
dyes)are not allowed in the City road right of way. Broom
finish only. An inspection by Public Works Engineering is
required prior to pouring concrete. Public,Works inspection
request line 417-4831,
----------------------------------------------------------------------------
Other Fees . . . . . . . . . RES UNDERGRND SERVICE FEE 770.00
SEWER SYSTEM DELV CHARGE 2260.00
STATE SURCHARGE 4.50
PW WATER SYSTEM USE FEE 2260.00
------------------------------------- ---------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 1369.65 1369.65 .00 .00
Plan Check Total 710.48 �710.48 .00 .00
Other Fee Total 5294.50 5294.50 .00
Grand Total 7374.63 7374.63 .00
Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes
null and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned
for a period of 180 days after the work has commenced, or if required inspections have not been requested within 180 days from the
last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions
of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does
not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construction.
Date Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder)
T:Forms/Building Division/Building Permit
BUILDING PERMIT INSPECTION RECORD
— PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS—
Building Inspections 417-4815 Electrical Inspections 417-4735
Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886
IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED.
POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE.
Inspection Type Date Accepted By Comments
FOUNDATION:
Footings
Sternwall
Foundation Drainage/Downspouts
Piers
Post Holes(Pole Bldgs.)
PLUMBING:
Under Floor/Slab
Rough-In
Water Line(Meter to Bldg)
Gas Line
Back Flow/Water FINAL Date Accepted by
AIR SEAL:
Walls
Ceiling
FRAMING:
Joists/Girders/Under Floor
Shear Wall/Hol�Downs
Walls/Roof/Ceiling
Drywall(Interior Braced Panel Only)
T-Bar
INSULATION:
Slab
Wall/Floor I Ceiling
MECHANICAL:
Heat Pump/Furnace/FAU/Ducts
Rough-In
Gas Line
Wood Stove/Pellet/Chimney
Commercial Hood/Ducts FINAL Date Accepted by
MANUFACTURED HOMES:
.Footing/Slab
16locking&Hold Downs
ISkirting
PLANNING DEPT. Separate Permit#s SEPA:
Parking/Lighting ESA:
Landscaping ISHORELINE:
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY1 USE
Inspection Type Date Accepted By
Electrical 417-4735
Construction- R.W. PW /Engineering 417-4831
Fire 417-4653
Planning 417-4750 1 1
Building 417-4815
T:Forms/Building Division/Building Permit
T
THF- For City Use
w''
et'V,G-4,
CtTY Or
Permit# 157- 17
Az '
W A S H I N- G- -T 0 N, U. S. Date Received: Z/-
321 E Sth Street Date Approved
Port Angeles,WA 9836 HL E b"0 P V
P:360-417-4817 F:360-417-4711
Email:permitsOcityofpa.us
BUILDING PERIPLICATION
Project Address: 2301 W. 16th Street Port Angeles, WA 98363
PHA Construction Supervisor Phone:360-912-0079
Primary Contact: I--, Email:bmccoppen@peninsulapha.org
Na 7t>dhristina Wonsey & Robert White Phone 360-452-6796
Property -MailingAddress 910 W. 14th Street Email famo4@q.com or robertfamo4@aol.com
Owner
city Port Angeles State WA "P 98363
Name Owner/Builder Phone
Contractor Address Email
Information city State
Contractor License# Exp.Date:
Legal Description: Zoning: Tax Parcel# Project Value: (materials and labor)
?64d6 /C5 '� b&-3Dol Y6- o 15-V $ 112,868.00
I Residential @ Commercial El Industrial El Public 11
Permit Demolition 11 Fire 11 Repair El Reroof(tear off/lay over) El
Classification For the following,fill out both pages of permit application:
(check New Construction R Exterior Remodel El Addition 11 Tenant Improvement 0
appropriate) I Mechanical 11 Plumbing 11 Other El
Fire Sprinkler System Proposed Irrigation System Proposed or Proposed Bathrooms Proposed Bedrooms
Pro'
or Existing? Yes 0 No El Existing? Yes 0 No El 2 3
F
In addition to standard hard copy submittals please send a PDF copy of all Stormwater plans and Engineering to
www.stormwaterC&cltyo a.us
Project Description New family residence with attached garage
11961,, 6y4w gV
Nle-w family residence with attached garage �54ELL-'&'
162y
Is project in a Flood Zone: Yes 11 No@ Flood Zone Type:
If in a Flood Zone, what is the value of the structure before proposed improvement? $
1 have read and completed the application and know it to be true and correct. I am authorized to apply for
this permit and understand that it is my responsibility to determine what permits are required and to
obtain permits prior to work. I understand that plan review fees are not refundable after review has
occurred. I understand that I will forfeit review fees if I withdraw the application before the permit is
issued. I understand that if the permit is not picked up/issued within 18o days of submittal,the application
will be considered abandoned and the fees will be forfeited.
Date Print Name Signature
Residential Structures
Existing Proposed Construction For Office Use
Area Descriptions(SQ FT) Floor area Floor area $Value new area
Basement
First Floor 1196 $101,660.00
Second Floor
Covered Deck/Porch/Entry 84 $1,008.00
Deck(over 30"or 2"d floor)
Garage 340 $10,200.00
Carport
Other(describe)
Area Totals 1620 $112,868.00
Commercial Structures
Area Descriptions(SQ FT) Existing Proposed Construction For Office Use
Floor area Floor area $Value new area
Existing Structure(s)
Proposed Addition
Tenant Improvement?
Other work(describe)
Site Area Totals
Lot/Site Coverage Calculations
Lot Size(sq ft) Lot Coverage(sq ft)foot print of %Lot Coverage(Total lot cov�lot size) Max Bldg Height
9024 1 all structures sq ft 17.9
Site Coverage(Sq Ft of all impervious) %of Site Coverage(total site cov�lot size)
2085 23.1
Mechanical Fixtures
Indicate how ma.ny of each type of ture to be installed or relocated as part of this project.
Air Handler I Size: # Haz/Non-Haz Piping Outlets:
Appliance Exhaust Fan # Heater(Suspended,Floor,Recessed wall) #
3
Boiler/Compressor Size: # Heating/Cooling appliance #
I repair/alteration
Evaporative Cooler(attached,not # Pellet Stove/Wood-burning/Gas #
portable) Fireplace/Gas Stove/Gas Cook Stove/Misc.
Fuel Gas Piping #of Outlets: Ventilation Fan,single duct #
3
Furnace/Heat Pump/ Size: # Ventilation System #
Forced Air Unit 12k BTU 1 1
Plumbing Fixtures
Indicate how many of each type of fixtu e to be installed or relocated
Plumbing Traps # Water Heater #
5
Plumbing Vent piping # Medical gas piping #of Outlets:
Water Line # Fuel gas piping #of Outlets:
Sewer Line # Industrial waste pretreatment
1 interceptor(Grease Trap) Size
Other(describe):
T:\BUILDING\APPLICATION FORMS\Current BP Application\Building Permit 4-17-13.docx
14 2 -%,iq 18 f4- 0 -1 Rf A
415 34 17
52 40 lb
16 33 4.1
4 6, 2 0827 26
3 ff---1 I
10 F32231,0- A15 2
2 28Z 2 1304
W 114 124 0 31 14 32
32 32 1M7
30� 29 71 8 23
2
4 Vlb 313
2 25 1322
21 321 3 61 1317 30
2446 31 0- 31 21
4 26
11 06, 20
1 41 45 13
3 6 27 33
1320
11, 910
33 28 13 T3 7 19 9
2 340
5
14 92 4. 18
3o2
1 411
14 2 /TU 50
4 4 31
2 31 91 '13 16 1�21 2
15 13
4 12 3
142 5 26
5 14 if
19
?-6
1 218
28
/s2o 40
7 -9
1 ol
17
13 2-30q 16 8 11J28 al 9 4
0�- 4092 16
14 50
15 15
12 10 173 0 8
622 142 15
2301 3 5 50 14
10 30 71 T�12 2 14
1 Egi
15 34 2125
30 220 131 1 1511 96
32 12
0 30
2 2
72
Oil 6
30
9 4
10 3 10
20 2
12
12
23
13
2
14
0 62 11 15
116,
2
CD
L
F, 95, 00+1
Ilk— NORTH
-SEWER S33 *1-4 14 7 m
LJ++ %
SITE PLAN
4* wo
MAX 2301 W 16TH
F�ORT ANGELES, W
L-L L�L
PENDLEY ESTATE LOT 15
s
�,D LOT SIZE 9024SF
LOT COVERAGE,1620/9024=17,c)/
SITE COVERAGE,2085/9024=23,17
c4�/ LA
C�
A LINES
In v
cu cu ni cv cu cu
N 33 1>1 4 om4 7 Lo Lo to to to in
......... . ......
.......... .............
::::Ptesdriptiv.e-:EiieraV..�C6de:C6mp.liance:�for:AII:Climate:.Zones�:.in:.Washington 11. .....
P
r9octlnfofhnatidn�
........................ ... ... ........
.................. ..................... ..........-- ........ . ....... .. .. .... .. .....
2,
Al g
'N'
This project will use the requirements of the Prescriptive Path below and incorporate the
the minimum values listed. In addition, based on the size of the structure,the appropriate
number of additional credits are checked as chosen by the permit applicant.
Authorized Representative Date
..... .... ....... .......
All Climate Zones
R-Valuea 1-1-Factora
Fenestration U-Factor b n/a 0.30
Skylight U-Factor n/a 0.50
Glazed Fenestration SHG Cb,, n/a n/a
Ceiling.. 4Y 0.026
Wood Frame Wal 19.kJ 21 int 0.056
Mass,Wall RNalue' 21/21h 0.056
Floor 309 0.029
Below Grade,Wal lc,k 10/15/21 int+TB 0.042
d
ISlab ::R-Value& Depth 1 10,2 ft n/a
*Table R402.1.1 and Table R402.1.3 Footnotes included on Page 2.
Each dwelling unit in one and two-family dwellings and townhouses,as defined in Section 101.2 of the
International Residential Code shall comply with sufficient options from Table R406.2 so as to achieve the
following minimum number of credits:
Ell.Small Dwelling Unit: 0.5 points
Dwelling units less than 1500 square feet in conditioned floor area with less than 300 square feet of fenestration
area. Additions to existing building that are less than 750 square feet of heated floor area.
n2. Medium Dwelling Unit: 1.5 points
All dwelling units that are not included in#1 or#3, including additions over 750 square feet.
El 3. Large Dwelling Unit: 2.5 points
Dwelling units exceeding 5000 square feet of conditioned floor area.
n4. Dwelling unit other than one and two-family dwellings and townhouses: Exempt
As defined in Section 101.2 of the International Residential Code
Table R406.2 Summary
Option.. Description
. . ... . redit(s)
C
la Efficient Building Envelope 1 a 0.5 El
lb Efficient Building Envelope lb 1.0
1c Efficient Building Envelope 1c 2.0
2a Air Leakage Control and Efficient Ventilation 2a 0.5
2b Air Leakage Control and Efficient Ventilation 2b 1.0
2c Air Leakage Control and Efficient Ventilation 2c 1.5 El
3a High Efficiency HVAC 3a 0.5 El
3b High Efficiency HVAC 3b 1.0 El
3c High Efficiency HVAC 3c 2.0 F-1
3d High Efficiency HVAC 3d 1.0 1.0
4 High Efficiency HVAC Distribution System 1.0
5a Efficient Water Heating 0.5
5b Efficient Water Heating 1.5
6 Renewable Electric Energy 0.5 1-1200 kwh 0.0
Total Credits 1.00
*Please refer to Table R406.2 for complete option descriptions
http:llwww.energy.wsu.edu/Documents/`Table 406 2 Energy Credits 2012 WSEC.Pdf
fill
21"
T---T
-4-
R)i
:T L
if
if
t-T ' '
I skbj 6Q49) i
An
r o-
41
(7-7
toi�-)b I
jj
9 f T 71�-7
..........
TTI
-4— -4- -4-4
!Gcl�
�01 - 41-i
LQG jq
Ti
q! '
7 17 LL
7,
It
ITU7GOi"Tf-,�,
ulls
Nil
I
I, T
fl
It Al it
-,r7i f-3
--717
T
—-----------T-
1 L
Z-11
F-L
71-
I i
T %
1 7-
oe
A-L-t
-211-1�16 41 �-I- �-Y
I
fill
ji It
it
It
A , j
166, ZiL# �61 16 '
A mA�
6 FU
L H�-
i
MECAWind Version 2 . 1 . 0 . 5 per ASCE 7-05
Developed by MECA Enterprises, Inc. Copyright 2012 www.mecaente�2rises.co
Date 10/16/2012 Project No. 12176
Company Name ZENOVIC & ASSOCIATES, INC. Designed By SRH
Address 301 EAST 6TH STREET, SUITE 1 Description 28x4O SFR
City PORT ANGELES Customer Name PENINSULA HOUSING AUTHORITY
State WA Proj Location CLALLAM COUNTY, WA
File Location: X:\12176 HOUSING AUTHORITY\ENGR\Structual\SFR DESIGN C.wnd
Detailed Wind Load Design (Method 2) per ASCE 7-05
Basic Wind Speed(V) 100.00 mph Structure Type Building
Structural Category II Exposure Category C
Natural Frequency N/A Flexible Structure No
Importance Factor 1.00 Kd Directional Factor 0.85
Alpha 9.50 Zg 900.00 ft
At 0. 11 Bt 1.00
Am 0.15 Bm. 0. 65
Cc 0.20 1 500.00 ft
Epsilon 0.20 Zmin 15.00 ft
Slope of Roof 4 : 12 Slope of Roof(Theta) 18.43 Deg
Ht: Mean Roof Ht 10.00 ft Type of Roof Gabled
RHt: Ridge Ht 12.00 ft Eht: Eave Height 8.00 ft
OH: Roof Overhang at Eave= .00 ft Roof Area 1316.00 ftA
2
Bldg Length Along Ridge 52.00 ft Bldg Width Across Ridge= 24.00 ft
Gust Factor Category I Rigid Structures Simplified Method
Gustl: For Rigid Structures (Nat. Freq.>1 Hz) use 0.85 = 0.85
Gust Factor Category II Rigid Structures - Complete Analysis
Zm: 0. 6*Ht = 15.00 ft
lzm: Cc* (33/Zm) ^0.167 0.23
Lzm: 1* (Zm/33) ^Epsiion 427.06 ft
Q: (1/ (1+0. 63* ( (B+Ht) /Lzm) ^0.63) ) ^0.5 0. 94
Gust2: 0. 925* ( (1+1.7*lzm*3.4*Q) / (1+1.7*3.4*lzm) ) 0.89
Gust Factor Summary
Not a Flexible Structure use the Lessor of Gustl or Gust2 0.85
Figure 6-5 Internal Pressure Coefficients for Buildings, GCpi
GCPi : Internal Pressure Coefficient +/-0. 18
Figure 6-6 External Pressure Coefficients
Cp - Loads on Main Wind-Force Resisting Systems(Method 2)
-6
heta
A k -4 T T T T T-F" T
h
z
J
Kh: 2.01* (Ht/Zg) ^ (2/Alpha) 0.85
Kht: Topographic Factor (Figure 6-4) 1.00
Qh: .00256* (V) A2*I*Kh*Kht*Kd 18.47 psf
Cpww: Windward Wall Cp(Ref Fig 6-6) 0.80
Roof Area 1316.00 ft^2
Reduction Factor based on Roof Area 0.80
MW'FRS-Wall Pressures for Wind Normal to 52 ft wall (Normal to Ridge)
wall Cp Pressure Pressure
+Gcpi (psf) -Gcpi (Psf)
--------------- ------ ----------- -----------
Leeward Wall -0.50 -11.18 -4.53
Side Walls -0.70 -14.32 -7.67
wall Elev Kz Kzt qz Press Press Total Shear Moment
ft Psf +GCpi -GCpi +/-GCpi Kip K-ft
------------------------------------------------------------- -----------------
Windward 12.00 0.85 1.00 18.47 9.24 15.89 t4l
12.74 76.42
Note: 1) Total = Leeward GCPi + Windward GC2i
2) Shear and Moment are sum of forces (Leeward+Windard) acting on bidg walls.
Note that the shear & moment don't consider loads on roof or end gable.
Roof Location Cp +Gcpi(psf) -GCpi(psf)
----------------------- ------- ---------- ----------
Windward - Min Cp -0.45 -10.39 -3.74
Windward - Max Cp 0.01 -3.17 3.48-7q,10
Leeward Perp to Ridge -0.57 -12.27 -5.62
Overhang Top (Windward) -0.45 -7.07 -7.07
Overhang Top (Leeward) -0.57 -8.95 -8.95
Overhang (Windward only) 0.80 12.56 12.56
MWFRS-Wall Pressures for Wind Normal to 24 ft wall (Along Ridge)
Wall Cp Pressure Pressure
+GCpi (psf) -GCp! (psf)
--------------- ------ ----------- -----------
Leeward Wall -0.29 -7.90 -1.25
Side Walls -0.70 -14.32 -7.67
Wall Elev Kz Kzt qz Press Press Total Shear Moment
ft psf +GCpi -GCpi +/-GCpi Kip K-ft
--------------------------------------------------------------------------------
Windward 12.00 0.85 1.00 18.47 9.24 15.89 17.14 4.94 29.62
Note: 1) Total = Leeward GCPi + Windward GCPi
2) Shear and Moment are sum of forces (Leeward+Windard) acting on bldg walls.
Note that the shear & moment don't consider loads on roof or end gable.
Roof - Dist from Windward Edge CP Pressure Pressure
+GCpi(psf) -GCpi(psf)
--------------------------------- ------ ---------- ----------
0.0 ft to 5.0 ft -0.90 -17.46 -10.81
5.0 ft to 10.0 ft -0.90 -17.46 -10.81
10.0 ft to 20.0 ft -0.50 -11.18 -4.53
20.0 ft to 52.0 ft -0.30 -8.04 -1.39
,5dll L/
MecaWind Pro v2 . 2 . 4 . 5 per ASCE 7-10
Developed by MECA Enterprises, Inc. Copyright www.mecaenterprises.co
Date 9/18/2014 Project No. JobNo
Company Name True Designed By Engineer
Address Address Description Description
City City Customer Name Customer
State State Proj Location Location
File Location: C:\Users\TRACY\ApoDal--a\Poaming\L',IecaW,nd\Defauic.wnd
Directional Procedure Simplified Diaphragm Building (Ch 27 Part 2)
Basic Wind Speed(V) 130.00 mph
Structural Category III Exposure Category C
Natural Frequency N/A Flexible Structure No
Importance Factor 1.00 Kd Directional Factor = 0.85
Alpha 9.50 Zg = 900.00 ft
At 0.11 Bt 1.00
Am 0.15 Bm 0.65
Cc 0.20 1 500.00 ft
Epsilon 0.20 Zmin 15.00 ft
Slope of Roof 4 : 12 Slope of Roof(Theta) 18.43 Deg
Ht: Mean Roof Ht 10.00 ft Type of Roof GABLED
RHt: Ridge Ht 12.00 ft Eht: Eave Height 8.00 ft
OH: Roof Overhang at Eave= .00 ft Overhead Type No Overhang
Bldg Length Along Ridge '= 52.00 ft Bldg Width Across Ridge= 24.00 ft
Gust Factor Calculations
Gust Factor Category I Rigid Structures Simplified Method
Gustl: For Rigid Structures (Nat. Freq.>l Hz) use 0.85 = 0.85
Gust Factor Category II Rigid Structures - Complete Analysis
Zm: 0.6*Ht = 15.00 ft
lzm: Cc*(33/Zm)^0.167 0.23
Lzm: 1*(Zm/33)^Epsilon 427.06 ft
Q: (1/(1+0.63*((B+Ht)/Lzm)^0.63))^0.5 0.94
Gust2: 0.925*((1+1.7*lzm*3.4*Q)/(1+1,7*3.4*izm)) 0.89
Gust Factor Summary
Not a Flexible Structure use the Lessor of Gustl or Gu3t2 0.85
Table 26.11-1 Internal Pressure Coefficients for Buildings, GCpi
GCPi Internal Pressure Coefficient +/-0.18
Topographic Adjustment
0.33*z 1.00
Kzt (0.33*z) : Topographic factor at elevation 0.33*z 1.00
Vtopo: Adjust V per Para 27.5.2: V * [Kzt(O.33*z)]^0.5 130.00 mph
MWFRS Diaphragm Building Wind Pressures per Ch 27 Pt 2
All pressures shown are based upon ASD Design, wiEn a Load Factor of .6
MWFRS Pressures for Wind Normal to 52 ft wall (Normal to Ridge)
WALL PRESSURES PER TABLE 9-7.6-1
L/B: Bldg Dim in Wind Dir / Bldg Dim Normal to Wind Dir 0.46
h: Height to top of Windward Wall 8.00 ft
ph: Net Pressure at top of wall (windward + leeward) 21.18 psf
pO: Net Pressure at bottom of wall (windward + leeward) 21.18 psf
ps: Side wall pressure acting away from wall � .54 * ph -11.44 psf
pl: Leeward wall pressure acting away from wall .38 * ph -8.05 psf
pwh: Windward wall press @ top acting toward wall ph-pl 13.13 psf
pwO: Windward wall press @ bot acting toward wall pO-pl 13.13 psf
ROOF PRESSURES PER TABLE 27.6-2)
h: Mean Roof Height 10.000 ft
Lambda: Exposure Adjustment Factor 1.000
Slope: Roof Slope 18.43 Deg
Zone Load Casel Load Case2
PSE psf
---- ---------- ----------
1 -15.99 5.54
2 -12.90 -b.70
3 -19.86 .00
4 -17.70 .00
'Jd 'q' d//�/
5 -14.52 .00
Note: A value of '0' indicates that the zone/load case is not applicable.
Notes - Normal to Ridge
Note (1) X= Along Building ridge, Y = Normal to Building Ridge, Z = Vertical
Note (2) MIN = Minimum pressures on Walls = 9.6 psf and Roof = 4.8 psf
Note (3) Area* = Area of the surface projected onto a vertical plane normal to wind.
MWFRS Pressures for Wind Normal to 24 ft wall (Along Ridge)
WALL PRESSURES PER TABLE 27.6-1
L/B: Bldg Dim in Wind Dir / Bldg Dim Normal to Wind Dir 2.17
h: Height to top of Windward Wall 12.00 ft
ph: Net Pressure at top of wall (windward + leeward) 18.36 psf
pO: Net Pressure at bottom of wall (windward + leeward) 18.36 psf
ps: Side wall pressure acting away from wall = .64 * ph = -11.75 psf
pl: Leeward wall pressure acting away from wall .27 * ph = -4.96 psf
pwh: Windward wall press @ top acting toward wall ph-pl 13.40 psf
pwO: Windward wall press @ bot acting toward wall pO-pl 13.40 psf
ROOF PRESSURES PER TABLE 27.6-2
h: Mean Roof Height 10.000 ft
Lambda: Exposure Adjustment Factor 1.000
Slope: Roof Slope 18.43 Deg
Zone Load Casel Load Case2
psf PSE
---- ---------- ----------
1 -15.99 5.54
2 -12.90 -5.70
3 -19.86 .00
4 -17.70 .00
5 -14.52 .00
Note: A value of '0' indicates that the zone/load case is not applicable.
Notes - Along Ridge
Note (1) X= Along Building ridge, Y = Normal to Building Ridge, Z Vertical
Note (2) MIN = Minimum pressures on Walls = 9.6 psf and Roof = 4.8 psf
Note (3) Area* = Area of the surface projected onto a vertical plane normal to wind.
Total Base Reaction Summary
Description FX Fy Fz MX MY MZ
Kip Kip Kip K-ft K-ft K-ft
--------------------------------------------------------------------------------------
Normal to Ridge Wall3+Roof +GCpi .0 8.2 18.0 40.4 .0 .0
Normal to Ridge Wails Only +GCpi .0 8.8 .0 35.2 .0 .0
Normal to Ridge Walls+Roof -GCpi .0 11.1 0.1 16.5 .0 .0
Normal to Ridge Walls Only -CCpi .0 8.8 .0 35-2 .0 .0
Normal to Ridge Walls+Roof MIN .0 .0 .0 .0 .0 .0
Along Ridge Walls+Roof +GCpi 4.4 .0 19.1 .0 -44.4 .0
Along Ridge Walls Only +GCpi 4.4 .0 .0 .0 -22.3 .0
Along Ridge Walls+Roof -GCpi 4.4 .0 .0 .0 -22.3 .0
Along Ridge Walls Only -GCpi 4.4 .0 .0 .0 -22.3 .0
Along Ridge Walls+Roof MIN .0 .0 .0 .0 .0 .0
Notes Applying to MWFRS Reactions:
Note (1) Per Fig 27.4-1, Note 9, Use greater of Shear calculated with or without roof.
Note (2) X= Along Building ridge, Y = Normal to Building Ridge, Z Vertical
Note (3) MIN = Minimum pressures on Walls = 9.6 psf and Roof = 4.8 P3f
Note (4) MIN area is the area of the surface onto a vertical plane normal to wind.
Note (5) Total Roof Area (inci OH Top) = 1315.51 sq. ft
Note (6) LC = Load Case (Some pressures can be zero, ref ASCE 7-10 Ch 27 Pt 2)