HomeMy WebLinkAbout3713 Mount Angeles Road Address:
3713 Mount Angeles Road
PREPARED 3/07/16, 12:42:13 INSPECTION TICKET PAGE 6
CITY OF PORT ANGELES INSPECTOR: JAMES LIERLY DATE 3/07/16
------------------------------------------------------------------------------------------------
ADDRESS . : 3713 MT ANGELES RD SUBDIV:
CONTRACTOR : PHONE
OWNER Maureen Sandison PHONE
PARCEL 06-30-14-3-1-9110-0000-
APPL NUMBER: 16-00000252 RES MECHANICAL PERMIT
------------------------------------------------------------------------------------------------
PERMIT: ME 00 MECHANICAL PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
--------------------- ----------------------------------:----------------------------------
L MECHANICAL FINAL
ME99 01 3/07/16 March 7, 2016 9:43:49 AM jlierly.
nKaren 457-4508
---- ----------- COMMENTS AND NOTES --------------------------------------
CITY OF PORT ANGELES
oo DEPARTMENT OF COMMUNITY& ECONOMIC DEVELOPMENT- BUILDING DIVISION
321 EAST 5TH STREET, PORT ANGELES, WA 98362
Application Number . . . . . 16-00000252 Date 2/24/16
Application pin number . . . 143616
Property Address . . . . . . 3713 MT ANGELES RD
ASSESSOR PARCEL NUMBER: 06-30-14-3-1-9110-0000- REPORTSALES TAX
Application type description RES MECHANICAL PERMIT on your state excise tax'form
Subdivision Name . . . . . .
Property Use . . . . . . . . RESIDENTAL SF 9000 to the City of Port Angeles
Property Zoning . . . . . . . RS9 RESDNTL SINGLE FAMILY
Application valuation . . . . 6829 (Location CodeV502) ,
----------------------------------------------------------------------------
y Application desc
REPLACEMENT OF OUTDOOR HEAT PUMP UNIT
----------------------------------------------------------------------------
Owner Contractor
------------------------ ------------------------
Maureen Sandison OWNER
3713 Mt. Angeles
PORT ANGELES WA 98362
— -----------------------------------L-------------------------------------------
Permit . . . . . . MECHANICAL PERMIT
Additional desc . .
Permit Fee . . . . 64.80 Plan Check Fee .00
Issue Date . . . . 2/24/16 Valuation . . . . 0
Expiration Date . . 8/22/16
Qty Unit Charge Per Extension
BASE FEE 50.00
1.00 14.8000 EA ME-FURN/HP/FAU < OR = 5 TON 14.80
----------------------------------------------------------------------------
Special Notes and Comments
Per Washington State Code 51-51-315,
installation of Carbon Monoxide
detector(s) is required if you are
installing or replacing a fuel burning
appliance (wood, pellet, gas)and must be
in place prior to the final inspection
of this permit. They are required to be
place directly outside of each sleeping
area and at least one on each floor of
the house.
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- -------7-- ----------
Permit Fee Total 64.80 64.80 .00 .00
Plan Check Total .00 .00 .00 .00
Grand Total 64.80 64.8Q .00 .00
06
Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes
null and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned
for a period of 180 days after the work has commenced, or if required inspections have not been requested within ISO days from the
last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All.provisions
6f laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does'
not presume to give authority to violate or cancel the provisions of an state or local law regulating construction or the performance of
construction.
Date Print Name Signature��Coynacto 0 Authorized Agent Signature of Owner(if owner is builder)
T:Forms/Building Division/Building Permit
BUILDING PERMIT INSPECTION RECORD
PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS-
Building Inspections 417-4815 Electrical Inspections 417-4735
Public Works Utilities 417-4831 Backfiow Prevention Inspections 417-4886
IT IS UNLAWFUL TO COVER,INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED.
POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE.
Inspection Type Date Accepted By Comments
FOUNDATION:
Footings
Stemwall
Foundation Drainage I Downspouts
Piers
Post Holes(Pole Bldgs.)
PLUMBING:
Under Floor/Slab
Rough-in
Water Line(Meter to Bldg)
Gas Line
Back Flow/Water
AIR SEAL:
Walls
Ceiling
FRAMING:
Joists/Girders/Under Floor
Shear Wall/Hold Downs
Walls/Roof/Ceiling
Drywall(interior Braced Panel Only)
T-Bar
INSULATION:
Slab
Wall/Floor/Ceiling
MECHANICAL:
Heat Pump/Furnace/FAU/Ducts
Rough-In
Gas Line
Wood Stove/Pellet/Chimney
Commercial Hood/Ducts
MANUFACTURED HOMES:
Footing/Slab
Blocking&Hold Downs
jSkirting
PLANNING DEPT. Separate Permit#s SEPA:
Parking/Lighting ESA:
Landscaping SHORELINE:
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY1 USE
Inspection Type Date Accepted By
Electrical 417-4735
Construction -R.W. PW I Engineering 417-4831
Fire 417-4653
Planning 417-4750
1 Building 417-4815
02/22/2016 06:26 13604525177 ALL WEATHER HEATING PAGE 01/03
TmF- For City Use
CITY OFr -Cy-6-�'
Permit#
W A S H I N G T 0 N, U. S. Date Received;
3 2 1 E Sth Street Date Approved '7- 5z— 1 0
Port Angeles,WA 9836
P,360-417-4817 F.360-417-4711
Email.permitUM-0.1yDivam BUILDING PERMIT APPLICATION
Project Address:3713 Mt. Angeles Road
Pbone:360-457-4508
Primag Contact:Maureen Sandison Eynail:
N.vne Maureen Sandison Pharw 360-457-4508
Property MaMing Addreu Eman
Owner city 3713 Mt. Angeles Rd State
Port Angeles WA 7"P 98362
Name All Weather Heating & Cooling, Inc. Phone 360-452-9813
Contractor Addre"302 Kemp Street Email billing@allweatherhc.com
Information c-ity Port Angeles StatewA 71P 98362
ContractorLicen9c4ALLVVEHC150KU J Exp.Date-9116
Legal Description: Zoning: Tax Parcel# Project Value: (materiab;and labor)
1 1 J $ 6829.20
Residential 10 Commercial 11 Industrial 1:1 Public 0
Permit Demolition 11 Fire El Repair 0 Reroof(teat off/lay over) El
Classification For the falla3ldng.B11 out both pages-of permit anglicatiom:
(check New Construction 0 Exterior Remodel 13 Addition 0 Teriant Improvement L3
OPPr"Pr"'t') Mechanical 9 Plumbing El Other 0
F orExisdiog? Yes 13 No sed I Irrigatio —�Posed Bathroom osed Bedrooms
ire Sprinkler Systern Propo n System Proposed o
13 Existing? Yes 0 No 0
In addition to standard hard copy submittalsPlease send a PDF copy of 41.1 Stormwater plans and Engineering to
NNE.Stormwaterp-c"9&a.us
Project Descri]etion Dked replacemnt of outdoor heat pump uinilt,
Diked moacement of outdoor heat pump udlL
Is project in a Flood Zone: Yes El No13 Flood Zone Type:
If in a Flood Zone, what is the value of the structure before proposed improvement? $
1 have read and completed the application and know it to be true and correct. I am authorized to apply for
this permit and understand that it is my responsibility to determine what permits are required and to
obtain permits prior to work. I understand that plan review fees are not reftindable after review has
occurred. Uunderstand that I will.forfeit review fees if T withdraw the application before the permit is
issued. I understand that if the permit is not picked up/issued within.x8o days of submittal,the application
will be considered abandoned and the fees will.be forfeited.
Karen McKeown
Date Print Name �:tgnature
Address:
ount Angeles Road
'9,-713 m� , �-Vpl
PREPARED 7/31/15, 9:31:37 INSPECTION TICKET PAGE 7
CITY OF PORT ANGELES INSPECTOR: JAMES LIERLY DATE 7/31/15
------------------------------------------------------------------------------------------------
ADDRESS . ; 3713 MT ANGELES RD SUBDIV:
CONTRACTOR POWER TRIP ENERGY CORP PHONE (360) 643-3080
OWNER CORN JOE B PHONE
PARCEL 06-30-14-3-1-9110-0000-
APPL NUMBER: 15-00000701 RES SOLAR PROJECT
------------------------------------------------------------------------------------------------
PERMIT: BSOL 00 BUILDING PERMIT - SOLAR
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
BL99 01 7/31/15 L�JLA BLDG FINAL
July 30, 2015 1:04:38 PM jlierly.
360-643-3080 BOBBIE
--------------------------------------
------------------- ---------- COMMENTS AND NOTES
CITY OF PORT ANGELES
DEPARTMENT OF COMMUNITY & ECONOMIC DEVELOPMENT- BUILDING DIVISION
321 EAST 5TH STREET, PORT ANGELES,WA 98362
N
Application Number . . . . . 15-00000701 Date 6/18/15
Application pin number . . . 402644
Property Address . . . . . . 3713 MT ANGELES RD
ASSESSOR PARCEL NUMBER: 06-30-14-3-1-9110-0000- REPORT SALES TAX
Application type description RES SOLAR PROJECT on your state excise tax form
Subdivision Name . . . . . .
Property Use . . . . . . . . RESIDENTAL SF 9000 to the City of Port Angeles
Property Zoning . . . . . . . RS9 RESDNTL SINGLE FAMILY (Location Code 0502)
Application valuation . . . . 17975
---------------------------------------------------------------------------- -
Application desc
RESIDENTIAL ROOF MOUNTS SOLAR ARRAY
-----------------------------------------------------------------------------
Owner Contractor
------------------------ ------------------------
CORN JOE B POWER TRIP ENERGY CORP
1317 E 7TH ST 83 DENNY AVE
PORT ANGELES WA 983626605 PORT TOWNSEND WA 98368
(360) 643-3080
----------------------------------------------------------------------------
Permit . . . . . . BUILDING PERMIT - SOLAR
Additional desc . . RES SOLAR GRID TIE ROOF MOUNTE
Permit Fee . . . . 130.00 Plan Check Fee .00
Issue Date . . . . 6/18/15 Valuation . . . . 17975
Expiration Date . . 12/15/15
Qty Unit Charge Per Extension
BASE FEE 130.00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
------ --- ----- ------ ------ --- ---
Permit Fee Total 130.00 130.00 00 00
Plan Check Total .00 .00 .00 .00
Grand Total 130.00 130.00 .00 .00
Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes
null and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned
for a period of 180 days after the work has commenced, or if required inspections have not been requested within 180 days from the
last inspection. I hereby certify that I have read and examined this application and know the-same to-be true and correct. All provisions
of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does
not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construction.
-�� 11�etpAo
Date Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder)
T:Forms/Building Division/Building Permit
BUILDING PERMIT INSPECTION RECORD
— PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS—
Building Inspections 417-4815 Electrical Inspections 417-4735
Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886
IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED.
POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE.
Inspection Type Date Accepted By Comments
FOUNDATION:
Footings
Stemwall
Foundation Drainage/Downspouts
Piers
Post Holes(Pole Bldgs.)
PLUMBING:
Under Floor/Slab
Rough-in
Water Line(Meter to Bldg)
Gas Line
Back Flow/Water FINAL Date Accepted by
AIR SEAL:
Walls
Ceiling
FRAMING:
Joists/Girders/Under Floor
Shear Wall/Hold Downs
Walls/Roof/Ceiling
Drywall(interior Braced Panel Only)
T-Bar
INSULATION:
Slab
Wall/Floor/Ceiling
MECHANICAL:
Heat Pump/Furnace/FAU/Ducts
Rough-In
Gas Line
Wood Stove/Pellet/Chimney
Commercial Hood/Ducts FINAL Date Accepted by
MANUFACTURED HOMES:
Vooting/Slab
113locking&Hold Downs
ISkirting
PLANNING DEPT. Separate Permit#s SEPA:
Parking/Lighting ESA:
Landscaping ISHORELINE:
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY1 USE
Inspection Type Date Accepted By
Electrical 417-4735
Construction- R.W. PW I Engineering 417-4831
Fire 417-4653
Planning 417-4750
L Building 417-4815
T:Forms/Building Division/Building Permit
CITY OF PORT ANGELES
DEPARTMENT OF COMMUNITY &ECONOMIC DEVELOPMENT-BUILDING DIVISION
321 FAST 5TH STREET, PORT ANGELES,WA 98362
Application Number . . . . . 15-00000701 Date 6/18/15
Application pin number . . . 402644
Property Address . . . . . . 3713 MT ANGELES RD
ASSESSOR PARCEL NUMBER: 06-30-14-3-1-9110-0000- REPORT SALES TAX
Application type description RES SOLAR PROJECT
Subdivision Name . . . . . . on your state excise tax form
Property Use . . . . . . . . RESIDENTAL SF 9000 to the City of Port Angel es
Property Zoning . . . . . . . RS9 RESDNTL SINGLE FAMILY
Application valuation . . . . 17975 (Location Code 0502)
----------------------------------------------------------------------------
Application desc
RESIDENTIAL ROOF MOUNTS SOLAR ARRAY
----------------------------------------------------------------------------
Owner Contractor
------------------------ ------------------------
CORN JOE B POWER TRIP ENERGY CORP
1317 E 7TH ST 83 DENNY AVE
PORT ANGELES WA 983626605 PORT TOWNSEND WA 98368
(360) 643-3080
------------------------------------------------------7---------------------
Permit . . . . . . BUILDING PERMIT - SOLAR
Additional desc . . RES SOLAR GRID TIE ROOF MOUNTE
Permit Fee . . . . 130.00 Plan Check Fee .00
Issue Date . . . . 6/18/15 Valuation 17975
Expiration Date . . 12/15/15-
Qty Unit Charge Per Extension
BASE FEE 130.00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 130,00 130.00 .00 .00
Plan Check Total .00 .00 .00 .00
Grand Total 130.00 130.00 .00 .00
U�v
/1 Ao�
6 Lj
Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements.This permit becomes
null and void ifwork or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned
for a period of 180 days after the work has commenced,or if required Inspections have not been requested within 180 days from the
last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions
of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does
not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construction.
Date Print Name Signaturl Contractor or Qrized Agent Signature of Owner(if owner Is builder)
T:Forms/Building Division/Building Permit
'ORT For City Use
3
THE -r
F i
CfTY 0 1- ;' LES
-J.16- Permit#
W A SH INGTO. N. U. S.
Date Received:
321 E 51b Street Date Approved 6�Y-�q-
Port Angeles,WA 9836
P:360-417-4817 F:360-417-4711
Email:permitsocilyo BUILDING PERMIT APPLICATION
Project Ad&ess: Aakwr AN4-c-,�tF5
70vie�--TP-1p E"ep-49 C-e- Phon e: 3 0 9 0 ro Fk--c IT) 36 o q,3 Lb
PrimaryContact- -,T0Kf-1 FLEt-w4cy �Email: '40W-1 a
Nam�r
C M44�EE�J SAqb1,<,0,q Phone -34�o-45'[ 450�b
Property Mailin Address Email
-7 - C&M
Owner -;;. m.r."
City F6 p- State WA- Zip q?36 7-
Name Phon
PCIV13 0R-Tlu P E14 eA-&l co, '(S(�0)
Contractor Address Email —
Information Put-," AAE . -46hm
city 'FoA:.- T-cwmse�-t4b State Wk zip 9 BSI;2,
Contractors license# ?0W1FkTE 9-34aff Exp.Date: ti
Legal Description: Zoning: Tax Parcel#67jV,--10 Project VaJue: (materials and labor)
$
Residential Commercial ff Industrial Public
Permit Demolition 0 Fire 0 Repair 11 Reroof(tear off/lay over)
Classification For the following,fill out both pages of permit allplication:
(check New Construction El Exterior Remodel El Addition 0 Tenant improvement 0
appropriate) -L Mechanical 1:1 Plumbing 0 Other n
Fire Sprinkler System? Irrigation System? Proposed Bathrooms Proposed Bedrooms
Yes 13 No 5L Yes 13 No S
Project Description Accr- 6ipub�-Tie- b P V
Is project in a Flood Zone: Yes 13 NoIM Flood Zone Type:
If in a Flood Zone, what is the value of the structure before proposed improvement? $
I have 'read and completed the application and know it to be true and correct.I am authorized to apply for
this permit and understand that it is my responsibility to determine what permits are required and to
obtain permits prior to work. I understand that plan review fees are not refundable after review has
occurred. I understand that I will forfeit review fees if I withdraw the application before the permit is
issued. I understand that if the permit is not picked up/issued within i8o days of submittal,the application
will be considered abandoned and the fees will be forfeited.
Date Print Name Signi
.. ,
No
Rec'd
HTE
Apprv'd
$130 Fee
Application and Checklist for Roof Mounted Residential Solar Panels
Project Information:
Property Owner Name: Joe Corn&Maureen Sandison
Project Address: 3713 S. Mt.Angeles Rd, PA Phone:360-457-4508
Contractor Name: Power Trip Energy Co Registration#: POWERTE934QE
Contractor Phone: 360-643-3080
PV system Roof mounted grid tied 6.05 kW Mfg/model#of major equip:SolarWorld
description: 22.modules,6 kW inverter 275 watt Protect PV modules,SMA 6000TIL-
US-22 inverter
Per WAC 51-51-2300,if the answer to the following cluestions is"yes"a building permit will be
issued for simple(10-lSkw output) PV systems without further engineering.
Section M2302.2.1—Where solar panels are installed on roofs,the roof structure shall be deemed adequate to
support the load of the rooftop if all of the following are met:
Yes No
1. PV system is designed and proposed for a single family or detached accessory structure El
2. The photovoltaic panels and modules and supporting structure shall be constructed of
noncombustible materials or fire-retardant treated wood equivalent to that required for the
roof construction. The installation shall meet the requirements of the International Fire Code
as amended by WA State. PV modules are listed and labeled with a fire classification in
accordance with UL 1703
3. The PV system is designed for the wind speed of the local area and will be installed per the
manufacturer's specifications.
4. The ground snow load does not exceed 70 pounds per square foot.The PV system is designed
for the wind speed of the local area,and will be installed per the manufacturer's specifications.
5. Total dead load of modules,supports,mountings,raceways and all other appurtenances weigh El
no more than four pounds per square foot. Enter total dead load of system (IbS/ft). [3.00 PSF
6. Supports for solar modules are installed to spread the dead load across as many roof-framing
members as needed to ensure that no point load exceeds fifty(50) pounds. Modulesare
mounted no higher than 18"above the surface of the roofing to which they are affixed and do
not exceed the highest point of the roof unless approved by the local jurisdiction.
NOTE: If site inspection indicates a concern that the roof structure is not adequate to
support the PV modulle(s), engilne6ring may be required prior to final of the permit.
As the property owner or authorized representative of the above listed property, I attest that all
information in this checklist is accurate to the Oest of my knowledge.
Applicant Signature:
Date: 6/17/2015
Applicant Name(Please Print)- Lj)hn S. Fleming,Power Trip Energy Co
Relationship to Property Owner: Installation Contractor
T:\BUILDING\APPLICATION FORMS\SOLAR PERMIT CHECKLIST.DOCX
Rook Rd
City of PA Litility net
Rook Rd
meter on pedestal
NORTH
South Mt Angeles Rd
New PV array
1;FDII0CF:'C'---z:�. P
Service panels inside
-VI west wall of garage
JOE- COLARIr"
MAUREENSolar production metej�
AC disconnect on west
e rior wall
L'I' M M-06",
Sunmodule;.,/ Protect SOLARWORLD,
SW275 MONO REALVALUE
L
TILIV Power controlled:
Lowest measuring tolerance in industry
Every component is tested to meet
3 times IEC requirements
Designed to withstand heavy
accumulations of snow and ice
Sunmodule Protect:
Positive performance tolerance
30-year linear performance warranty
and 10-year product warranty
Glass with anti-reflective coating
World-class quality
Fully-automated production lines and seamless monitoring of the process and material ensure
the q ua I ity that t he com pany sets a s its ben&ma rk fo r its s ites worldwide.
Innovative glass technologies make extremely weather-resistant and robust solar modules POS-
sible.The Sunmodule Protect offers higher mechanical resilience and a longer Service life,and still
weighs the same as the Sunmodule Plus. C CW1 S
The positive power tolerance guarantees utmost system efficiency.Only modules achieving or UL 1703
exceeding the designated nominal power in performance tests are dispatched.The power toler-
ance ranges between-0 Wp and+5 Wp.
� 7 !
SolarWorld is setting new standards with the ground-breaking 30-year linear performance guar-
antee:a maximum degradation of just 0.35%p.a.provides guaranteed module performance of
90%after 21 years,and 86.85%after 30 years.'
30-year linear performance guarantee
Linear performance guarantee for SolarWorld Sunmodule Protect
Linear performance guarantee for SolarWorld Sunmodule Plus
Competitor's tiered performance guarantee
0%
!'A
3E
0%
1 5 10 is 20 25 30
Ycars
'in accordance with the applicable SolarWorld Limited Warranty at purchase. NIELM—
www.solarworld,com/warranty
MADE IN USA OF US
solarworld.com A.413 WAPORTED PARTS
Sunmodule;/ Protect
SW275 MONO 64-11 REALVALUE
PERFORMANCE UNDER STANDARD TEST CONDITIONS(STC)' PERFORMANCE AT 800 W/M',NOCT,AM 1.5
Maximumpower p- 275 Wp Maximum power p— 205.0 Wp
Open circuit voltage V__ 39.4 V Open circuit voltage V� 36.1 V
Maximum powerpoint voltage V—P 31.0 V Maximum power point voltage V11- 28.4 V
Short circuit current 9.58 A Short circuit current ll� 7.75 A
Maximum power point current 8.94 A Maximum power point current 1�pp 7.22 A
Module efficiency 16.40% Minorreduction in efficiency under pdrtial luad cLfiditiorisat25*C:at200%,V/M2,100%
(+/-2%)of the STC efficiency(1000 W/m�)is achreved-
*STC:1000 W/ml.25'C,AM 1.5
1)Measuring tolerance(P,,,)traceable to TUV Rheinland:t/-2%(TUV Power Controlled), COMPONENT MATERIALS
THERMAL CHARACTERISTICS Cells per module 60
NOCT 46*C Cell type Monocrystalline
TC 1, 0.04%1-C Celldimensions 6.14 in x 6.14 in(156 rnm x 156 mm)
TC V., -0,30%/'C Front Heat treated(EN 6121S)
Tic P, -0.41%/�C Frame Clear anodized aluminum
Operating temperature -40*C to 85*C weight 46.7 1 bs(21.2 kg)
:C-mm S .5 k-4 v*j
SYSTEM INTEGRATION PARAMETERS
1000 WJM2 Maximum system voltage SC I//NEC 1000V
Maximum reverse current 16 A
800 W/m. Number of bypass diodes 3
____600W/rn1____ Design Loads* -a rail system 113 psf downwar
64 psf upward
V
�A
3
,rd
ird
Design Loads* Threerailsystem 170psfdownward
400 Wlmz 71 psf u pwa rd
0 Design Loads* Edge mounting 30 psf downward
200 W/ml 30 psf upward
100 W/m2 Please referto the Sunmodulemstalla'tion instructions'or the details associated with
these load cases
Module voltage M V_ ADDITIONAL DATA
Powersorting' -0 Wp/+5 Wp
-L-x 4 37�44(951) J-Box IP65
Module leads PV wire per UL4703 with H4 connectors
T Module type(UL 1703) 3
11.33(288) Glass Low iron tempered with ARC
39.37(100
VERSION 2.S FRAME
Version Compatible with both"Top-Down"
and"Bottom"mounting methods
2.5frame
65.94(1675) bottom 4Grounding Locations:
mounting 4comers of the frame
holes 4 locations along the length of the
L module in the extended flanget
=L-x4
4.20(107)t
39.41(1001)
U2(31)
All units provided are imperial-Sl units provided in parenthese5_
SolarWorld AG reserves the right to make specification changes without notice, SW-01-6045US 08-2014
Friday,Janum-y 31,2014
Sna �rack-
SnapNrack
o r m a n 775 Fiero Lane,Suite 200
San Luis Obispo,CA 93401
Scheel "Series 100 Roof Mount" Cover Letter
To Whom It May Concern,
We have performed calculations for the 100 series roof mount PV system based on
Structural the information provided by SnapNrack. Included with this letter are the report and
calculations. We did the calculations in accordance with the 2012 IBC, ASCE 7-10,
2112 NDS, and guidelines stated in the Solar America Board for Codes arid
En g i n e e r Standards.
Some of the components in the SnapNrack test data were used to determine the
5022 Sunrise Blvd. capacity and section properties of materials. We collected the test data using the
Fair Oaks,CA 95628 procedures outlined in the 2012 IBC Chapter 17.
(916)536-9585
(916)536-0260(fax) We included the following types of load combinations and building parameters into
our calculations:
1989-2013
24 years of e.rcellence
ASCE 7-10 wind speeds from 110 mph to 190 for B and C exposure
categories
ASCE 7-10 Seismic Design Category E
ASCE 7-10 Snow Loads up to 120 psf ground snow
0 Buildings with mean roof heights up to 60 foot tilt angles / roof pitches
Norman Scheel,S.E. from 0 degrees to 60 degrees.
LEED AP BD+C
LEED AP Homes The calculations have also been completed in accordance with the 2006 IBC,2009
Fellow—SEAOC IBC, and ASCE 7-05. To use the data contained in this packet for projects that are
.Fellow-ASCE
E-mail:norm(i-Ossexo being evaluated to the older ASCE 7-05 wind speeds,refer to Appendix A for a
Rob Coon wind speed conversion chart. Find the ASCE 7-05 (IBC 2006/2009)wind speed in
General Manager the Chart in Appendix A,identify the corresponding ASCE 7-10(IBC 2012)wind
r-mail:Tobcoon(a?nsse.co speed value,and proceed with using the charts contained in this packet with the
Steve Smith P.E. adjusted wind speed value.
Project Manager
E-mail:stevesmith(a-Insse.com In our opinion, the mounting system, outlined by SnapNrack Series 100 PV
Mounting System Code Compliance Installation Manual, is acceptable and meets
Steven Cooksey the loading requirements as stated above. See the report and calculations included
CAD Supervisor
E-mail:stevcnamsse.co with this letter for more information.
Jaclde Winslow If there are any further questions,please contact Norm Scheel. J. SO,
Orfice Manager
E-mail;iockicCalnssc-com Norman Scheel PE, SE
LEED-AP BD+C,LEED-AP Homes
Fellow Sji%kOC
Fellow 1A.C.E.
EXPIRES DECEMBER 26, L.02
!?J
SnapNrack Series 100 Snap rack-
ProjectInfo:
Dealerd Power Trip Energy Co Project Name:1 Joe Corn,Maureen Sandison,Phq
Create Date:1 2015-06-17Tl6:04:17-0700 BOM#:1 33857
PV Module Data:
Module Brand SolarWorld Length 65.94 inches
Model SW275mono Width 39.41 inches
Depth 1.22 inches
Environmental Requirements: Weight 46.70 pounds
Topographic Condition Standard 71 Rated power @ STC 27500 W
Standard IBC 2012 1 Rail Color
Snow Load 21-30 psf — ITE Racking Color
Wind Speed 130 mph — ITSK 'A CH6e-K&:1'*T
Rafter Spacing 24 inches
Roof Attachment Flashed L-Foot
System Style:
Rail Finish Black Anodized
End Clamp Type Adjustable
Grounding Method UL 2703 Listed
Micro Attachment Kits No
Edge Screen Trim?, No if"Yes",4"or 8"screen? Screen Height inches
Tilt Up?[ No
Sub-Arrays: I UL2703 Yes Premium Alloy Ra—i—IFNo Bulk Customer No
Sub-Array Sub-Array 122" Rail 162" Rail Rail Mid End Edge Roof
Modules Splices Clamps Clamps Screen Attachments
1 22 12 2 6 36 16 0 44
TOTALS] 22 12 2 6 16 16 0 44
Page I of 3
Corn-Sandison Solar Racking
SnapNrack Series 100 Calculator
Proposed Bill of Materials
Part Number Description Qty
015-09822 SNAPNRACK,STANDARD RAIL SET,1221N,BLACK,6 PC 2
015-09818 SNAPNRACK,STANDARD RAIL SET,1621N,BLACK,2 PC 1
242-04015 SNAPNRACK,BONDING STANDARD RAIL SPLICE ASSEMBLY,BLACK 6
242-02050 SNAPNRACK,BONDING MID CLAMP ASSEMBLY,1.20-1.48IN,CLEAR 36
242-02065 SNAPNRACK,BONDING ADJUSTABLE X-END CLAMP ASSEMBLY,1.20-1.481N,CLEAR 16
232-01023 SNAPNRACK RAIL END CAP,STANDARD, BLACK 16
242-02700 SNAPNRACK,BONDING L-FOOT KIT W/BASE AND FLASHING,CLEAR L-FOOT 44
242-02101 SNAPNRACK,GROUNDING LUG ASSEMBLY 4
Total'Weight: 1SI.84 lbs
�-System Total Weight: 1240.00 lbs
jArray Area=22 modules x(40.4"x 67"/144 sq.inch per sf)=414 sf
jPounds per Square Foot of Array=1240 lbs/414 sf=3.00 psf Item 5 checklist
jPounds per attachment=1240 lbs/44=28.2 lbs per attachm ent Item 6 checklist
Page 2 of 3
Modules Per 7 Array Pitch(degrees) 0 Sub-Array Modules 22
Row
Nodule 4 Building Height(ft) 0 Edge Screen(ft) 0
Rows
Orientation Portrait Attachment Spacing 72 Attachment Spacing 48 Array Power(kW) 6.05
(inches) Override(inches)
The maximum recommended rail span for this sub-array is 72 inches.The rail span for modules located in edge zones is reduced by 24 inches to 48 inches
Group I Rail Group 2 Rail Group 3 Rail Group 4 Rail Group 5 Rail 122"Rail 162"Rail Row Mid Row End Row Attach- Module Rail
Length Length Length Length Length Qtv City Clamps Clamps Solices ments Bonding Bonding
241.46 4 0 10 4 2 12 0 1
241.46 4 0 10 4 2 12 0 1
241.46 4 0 10 4 2 12 0 1
161.64 0 2 6 4 0 8 0 1 EIFIDDE101:1
Sub-Array 12 2 36 16 6 44 0 4
Totals
Corn-Sandison Solar Racking Page 3 of 3