HomeMy WebLinkAbout402 Marine Drive (4) Address:
402 Marine Drive
PREPARED 10/20/15, 9:53:39 INSPECTION TICKET PAGE 5
CITY OF PORT ANGELES INSPECTOR: JAMES LIERLY DATE 10/20/15
------------------------------------------------------------------------------------------------
ADDRESS . : 402 MARINE DR SUBDIV:
CONTRACTOR : PHONE :
OWNER JUNAIB A RIZVI PHONE : (503) 484-3161
PARCEL 06-30-00-0-0-3503-0000-
APPL NUMBER: 15-00000946 COMM REMODEL
------------------------------------------------------------------------------------------------
PERMIT: BPC 00 BUILDING PERMIT - COMMERCT-AL
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
BL3 01 10/06/15 JLL BLDG FRAMING
10/06/15 DA October 6, 2015 9:22:33 AM jlierly.
Ahmed 301-433-5741
October 6, 2015 4:08:12 PM jlierly.
Support south wall ceiling with stud wall construction or
equal. Sht rock nailers reqd. No loading on ceiling above
office.JLL
BL3 02 10/09/15 PB BLDG FRAMING
10/09/15 AP October 9, 2015 9:09:41 AM pbarthol.
ahmed 301-433-5741
October 9, 2015 4:34:01 PM pbarthol.
BL3 03 10/19/15 JLL BLDG FRAMING
10/19/15 AP October 19, 2015 12:39:52 PM jlierly.
amhed 457-6350
October 19, 2015 3:51:02 PM jlirly.
BL99 01 10/20/15 BLDG FINAL
,07�� October 19, 2015 3:56:09 PM jliexly.
Ahmed 457-6350
-------------------------------------- COMMENTS AND NOTES --------------------------------------
CITY OF PORT ANGELES
DEPARTMENT OF COMMUNITY& ECONOMIC DEVELOPMENT-BUILDING DIVISION
CK ) 3 21 EAST 5TH STREET, PORT ANGELES,WA 983 62
Application Number . . . . . 15-00000946 Date 10/05/15
Application pin number . . . 152688
Property Address . . . . . . 402 MARINE DR
ASSESSOR PARCEL NUMBER: 06-30-00-0-0-3503-0000- REPORT SALES TAX
Application type description COMM REMODEL on your state excise tax fonn
Subdivision Name . . . . . .
Property Use . . . . . . . . to the City of Port Angeles
Property Zoning . . . . . . . COMMERCIAL ARTERIAL
Application valuation . . . . 600 (Location Code 0502)
----------------------------------------------------------------------------
Application desc
add walls for office space
----------------------------------------------------------------------------
Owner Contractor
------------------------ ------------------------
JUNAIB A RIZVI OWNER
402 MARINE DR
PORT ANGELES WA 98363
(503) 484-3161
- -----------------------------------------------------------------------------
Permit . . . . . . BUILDING PERMIT - COMMERCIAL
Additional desc ADD WALLS FOR OFFICE SPACE
Permit Fee 53.05 Plan Check Fee 34.48
Issue Date . . . . 10/05/15 Valuation . . . . 600
Expiration Date 4/02/16
Qty unit charge Per Extension
BASE FEE 50.00
--------1.00--------3.0500_HND___BL-501-2K (3.05-PER C)---------------3.05
---- ------ --- --------- ----- --- -- ----
Other Fees . . . . . . . . . STATE SURCHARGE 4.50
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 53.05 53.05 .00 .00
Plan Check Total 34.48 34.48 .00 .00
Other Fee Total 4.50 4.50 .00 .00
Grand Total 92.03 92.03 .00 .00
Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes
null and void ifwork or construction authorized is not commenced within 180 days,ifconstruction orwork is suspended orabandoned
for a period of 180 days after the work has commenced, or if required inspections have not been requested within 180 days from the
last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions
of laws and ordinances governing this type of work w"complied with whether specified herein or not. The granting of a permit does
not presume to give authority to violate or canc rovisions of any state or local law regulating construction or the performance of
constrvc i
"s-1
H M go IqAw
V
Date Print Name Sig��ture of Contractor or Authorized Agent Signature of Owner(if owner is builder)
T:Forms/Building Division/Building Permit
BUILDING PERMIT INSPECTION RECORD
— PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS—
Building Inspections 417-4815 Electrical Inspections 417-4735
Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886
IT IS UNLAWFUL TO COVER,INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED.
POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE.
Inspection Type Date Accepted By Comments
FOUNDATION:
Footings
Stemwall
Foundation Drainage/Downspouts
Piers
Post Holes(Pole Bldgs.)
PLUMBING:
Under Floor/Slab
Rough-In
Water Line(Meter to Bldg)
Gas Line
Back Flow/Water FINAL Date Accepted bV
AIR SEAL:
Walls
Ceiling
FRAMING:
Joists/Girders/Under Floor
Shear Wall/Hold Downs
Walls/Roof/Ceiling
Drywall(interior Braced Panel Only)
T-Bar
INSULATION:
Slab
Wall/Floor/Ceiling
MECHANICAL:
Heat Pump/Furnace/FAU/Ducts
Rough-In
Gas Line
Wood Stove I Pellet I Chimney
Commercial Hood/Ducts FINAL Date Accepted by
MANUFACTURED HOMES:
Footing/Slab
Blocking&Hold Downs
,Skirting
PLANNING DEPT. Separate Permit#s SEPA:
Parking/Lighting ESA:
Landscaping ISHORELINE:
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY1 USE
Inspection Type Date Accepted By
Electrical 417-4735
Construction-R.W. PW I Engineering 417-4831
Fire 417-4653
Planning 417-4750
Building 417-4815
T-Pnrm.0Rij11rfinn nivi.Rinn/Rifildinn Pprmit
THF- For City Use
'011)11'V
CITY OF 1%�IL
ANGELES
Permit# Ig—
Permitl
W A S H I N G T 0 N, U . S.
P� —'
Date Received: -7,
321 E 5th Street ate Approved
Port Angeles,WA 9836
P:360-417-4817 F:360-417-4711
Email:permitsOciiyofl2a.us BUILDING PERMI kAPLIC.AITION
Project Address: fl719-,e1A)& V4�7-7
Phone:
Primary Contact: *92y02g!J7b F'Mnil-
Name Phone
07W -F&Dzil I
Property Mail- Address Email
Owner J-&/?/Z-V[F 11,97'r2we- (f�- "
Cit
.)�' State
40 W)9 -
Name Phone
Contractor Address Email
Information city State Zip
Contractor License# Exp.Date:
Legal Description: Zoning: Tax Parcel# Proj ect I�AlUe;-(Taterials and labor)
$
Residential 11 Commercial Industrial El Public 1:1
Permit Demolition El Fire 11 Repair 0 Reroof(tear off/lay over) El
Classification For the following,fill out both pages of permit application:
(check New Construction 11 Exterior Remodel 1:1 Addition El Tenant Improvement
appropriate) 1 Mechanical El Plumbing 11 Other El
Fire Sprinkler System Proposed Irrigation System Proposed or Proposed Bathrooms Proposed Bedrooms
or Existing? Yes 0 No ;k Existing? Yes E3 No 11 1
In addition to standard hard copy submittals please send a PDF copy of all Stormwater plans and Engineering to
www.stormwaterocityof�a.us
Project Description O)gIL k7 1)719_A) �L)6(je
&Lmng-�Q
Is project in a Flood Zone: Yes 0 No[3 Flood Zone Type:
If in a Flood Zone,what is the value of the structure before proposed improvement? $
1 have read and completed the application and know it to be true and correct. I am authorized to apply for
this permit and understand that it is my responsibility to determine what permits are required and to
obtain permits prior to work. I understand that plan review fees are not refundable after review has
occurred. I understand that I will forfeit review fees if I withdraw the application before the permit is
issued. I understand that if the permit is not picked up/issued within i8o days of submittal,the application
will be considered abandoned and the fees will be forfeited.
7/,-R(?//!5 Rid< 'OV6,WIAC,�
Date Print Name Signature
Residential Structures A//,4
Existing Proposed Cofistruction For Office Use
Area Descriptions(SQ FT) Floor area Floor area $Value new area
Basement
First Floor
Second Floor
Covered Deck/Porch/Entry
Deck(over 30"or 2"d floor)
Garage
Carport
Other(describe)
Area Totals
Commercial Structures
Area Descriptions(SQ FT) Existing Proposed Construction For,Office Use
Floor area Floor area $Value new area
Existing Structure(s) 1576 0 Sq F=
Proposed Addition
Tenant Improvement?
Other work(describe)
Site Area Totals
Lot/Site Coverage Calculations
Lot Size(sq ft) Lot Coverage(sq ft)foot print of %Lot Coverage(Total lot cov lot size) Max Bldg Height
� all structures sq ft
Site Coverage(Sq Ft of all impervious) %of Site Coverage(total site cov-. lot size)
Mechanical Fixtures
Indicate how many of each type of xture to be installed or relocated as part of this project.
Air Handler I Size: # Haz/Non-Haz Piping Outlets:
Appliance Exhaust Fan # Heater(Suspended,Floor,Recessed wall) #
Boiler/Compressor Size: # Heating/Cooling appliance #
I repair/alteration
Evaporative Cooler(attached,not # Pellet Stove/Wood-burning/Gas #
portable) Fireplace/Gas Stove/Gas Cook Stove/Misc.
Fuel Gas Piping #of Outlets�� Ventilation Fan,single duct #
Furnace/Heat Pump/ Size: # Ventilation System #
Forced Air Unit -49-
Plumbing Fixtures
Indicate how many of each type of fixtu e to be installed or relocated
Plumbing Traps # Water Heater #
Plumbing Vent piping # Medical gas piping #of Outlets:
Water Line # Fuel gas piping #of Outlets:
Sewer Line # Industrial waste pretreatment
interceptor(Grease Trap) Size
Other(describe):
T:\BUILDING\APPLICATION FORMS\Current BP Application\Building Permit 4-17-13.docx
CJrV 6F dArSEL45rS
7Y q(7- q 315
qI-7 - 7 -------
t-YGrMr, COAAn�67F
zt
zo V—(H
S7 (7 '2
CITY OF PORT ANGELES-Construction Plans
Tlyd-Us-wan-denof Jhis��pf-m
specifications and other data shall not prevent the
5 .,-.-,.buiUng--Afficial-from--thereafter-.requiring---thw--�-------
correction of errors in said plans,specifications and
other data,or from preventing building operations
on ereun erw eninvioatoni)y
codes and ordinances of this jurisdiction.
2-15 12--
Address:
402 Marine Drive
PREPARED 9/30/16, 9:13:59 INSPECTION TICKET PAGE 4
CITY OF PORT ANGELES INSPECTOR: JAMES LIERLY DATE 9/30/16
------------------------------------------------------------------------------------------------
ADDRESS 402 MARINE DR SUBDIV:
CONTRACTOR JD CONSTRUCTION PHONE (206) 229-3557
OWNER J. C. COLUMBIA CORP PHONE (206) 245-0237
PARCEL 06-30-00-0-0-3503-0000-
APPL NUMBER: 16-00000630 COMM REMODEL
------------------------------------------------------------------------------------------------
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
7/15/16 AP OVERRIDE TAKEN BY JLIERLY DATE: 07/14/16 TIME: 09:59:06
July 14, 2016 10:07:52 AM jlierly.
chan 206-474-9363
July 15, 2016 4:24:12 PM jlierly.
PL99 01 9/30/16 PLUMBING FINAL
September 30, 2016 9:16:55 AM jlierly.
--------------------------------------
------------------- ------------ COMMENTS AND NOTES
PREPARED 9/30/16, 9:13:59 INSPECTION TICKET -'PAGE 3
CITY OF PORT ANGELES INSPECTOR: JAMES LIERLY DATE 9/30/16
------------------------------------------------------------------------------------------------
ADDRESS . ; 402 MARINE DR SU13DIV:
CONTRACTOR JD CONSTRUCTION PHONE �(206) 229-3557
OWNER J. C. COLUMBIA CORP PHONE (206) 245-0237
PARCEL 06-30-00-0-0-3503-0000-
APPL NUMBER: 16-00000630 COMM REMODEL
------------------------------------------------------------------------------------------------
PERMIT: BPC 00 BUILDING PERMIT - COMMERCIAL
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
BL3 01 7/21/16 JLL BLDG FRAMING
9/01/16 AP July 21, 2016 9:31:28 AN jlierly.
Chan 206-474-9363
September 1, 2016 9:52:04 AM jlierly.
BL99 01 9/30/16 BLDG FINAL
September 30, 2016 9:16:07 AM jlierly.
Mr Chang 206-229-3557
-------- -- -- ----- - - ------
PERMIT: ME---00-MEAICALFPERMIT------- --------------------------------------------------------
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
ME6 01 9/20/16 JLL MECHANICAL GAS LINE
9/20/16 AP September 20, 2016 8:13:54 AM jlierly.
Mr. Chang 206-229-3557
September 20, 2016 4:11:08 PM jlierly.
MGD 01 9/23/16 JLL MECHANICAL GREASE DUCTS
9/23/16 AP September 23, 2016 8:39:22 AM jlierly.
Mr. Chang 206-229-3557
September 23, 2016 4:18:08 PM jlierly.
ME2 01 9/26/16 JLL MECHANICAL HOOD / DUCT
9/27/16 AP September 26, 2016 10:10:15 AM jlierly.
1hr duct wrap inspection . Mr. Chang 206-229-3557
September 27, 2016 8:10:32 AM jlierly.
ME99 01 9/30/16 ECHANICAL FINAL
W Mseptember 30, 2016 9:16:36 Am jlierly.
------------------- - --- ---------------------------------------------------------------
PERMIT: PL 00 PL�JN E IT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
PL1 01 7/08/16 PB PLUMBING UNDER SLAB
7/11/16 DA July 8, 2016 11:02:21 AM pbarthol.
Mark 206-474-9363
July 11, 2016 8:18:08 AM pbarthol.
Prep sink not routed to grease trap.
PL2 01 7/08/16 PB PLUMBING ROUGH-IN
7/11/16 DA July 8, 2016 11:03:01 AM pbarthol.
Mark 206-474-9363
July 11, 2016 8:18:08 AM pbarthol.
Prep sink not routed to grease trap.
PL1 02 7/15/16 JLL PLUMBING UNDER SLAB
7/15/16 AP - OVERRIDE TAKEN BY JLIERLY DATE: 07/14/16 TIME: 10:03:55
July 14, 2016 10:08:55 AM jlierly.
July 15, 2016 4:24:12 PM jlierly.
PL2 03 7/15/16 JLL PLUMBING ROUGH-IN
----------------------------------- CONTINUED ONTO NEXT PAGE -----------------------------------
PREPARED 7/21/16, 9:28:36 INSPECTION TICKET PAGE 1
CITY OF PORT ANGELES INSPECTOR: JAMES LIERLY DATE 7/21/16
------------------------------------------------------------------------------------------------
ADDRESS . : 402 MARINE DR SUBDIV:
CONTRACTOR JD CONSTRUCTION PHONE (206) 229-3557
OWNER J. C. COLUMBIA CORP PHONE (206) 245-0237
PARCEL 06-30-00-0-0-3503-0000-
APPL NUMBER: 16-00000630 COMM REMODEL
------------------------------------------------------------------------------------------------
PERMIT: BPC 00 BUILDING PERMIT - COMMERCIAL
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
BL3 01 7/21/16 BLDG FRAMING
July 21, 2016 9:31:28 AM jlierly.
Chan 206-474-9363
-------------------------------------- COMMENTS AND NOTES --------------------------------------
CITY OF PORT ANGELES
DEPARTMENT OF COMMUNITY & ECONOMIC DEVELOPMENT- BUILDING DIVISION
321 EAST 5TH STREET, PORT ANGELES,WA 98362
Application Number . . . . . 16-00000630 Date 6/03/16 Goo,
Application pin number . . . 233380
Property Address . . . . . . 402 MARI14E DR REPORT SALES TAX
ASSESSOR PARCEL NUMBER: 06-30-00-0-0-3503-0000-
Application type description COMM REMODEL on your state excise tax form
Subdivision Name . . . . . .
Property Use . . . . . . . . to the City of Pod Angeles
Property Zoning . . . . .. . . COMMERCIAL ARTERIAL (Location Code 0502)
Application valuation . . . . 35000
- ----------------------------------------------------------------------------
Application desc
remove partition, build kitchen, new partition
- ----------------------------------------------------------------------------
Owner Contractor
------------------------ ------------------------
J. C. COLUMBIA CORP JD CONSTRUCTION
.: . -402 MARINE DR 15227 34TH DRIVE SE
PORT ANGELES WA 98363 MILL CREEK WA 98012
(206) 245-0237 (206) 229-3557
-------------------------------- -------------------------------------------
Permit . . . . . . BUILDING PERMIT COMMERCIAL
Additional desc NEW KITCHEN
Permit Fee . . . . 518.75 Plan Check Fee 337.19
Issue Date . . . . 6/03/i6 Valuation . . . . 35000
Expiration Date 11/30/16
Qty Unit Charge Per Extension
BASE FEE 417.75
10.00 10.1000 THOU BL-25,001-50K (10.10 PER K) 101.00
----------------------------------------------------------------------------
Permit . . . . . . MECHANICAL PERMIT
Additional desc
Permit Fee . . . . 60.65 Plan Check Fee .00
Issue Date . . . . 6/03/16 Valuation . . . . 0
Expiration Date 11/30/16
Qty Unit Charge Per Extension
BASE FEE 50.00
1.00 10.6500 EA ME-HOOD/DUCT-MECH. EXHAUST 10.65
----------------------------------------------------------------------------
Permit . . . PLUMBING PERMIT
Additional desc . .
Permit Fee . . . . 100.00 Plan Check Fee .00
Issue Date . . . . 6/03/16 valuation 0
Expiration Date 11/30-/16
Qty Unit Charge Per Extension
BASE FEE 50.00
4.00 7.0000 EA PL-PLUMBING TRAP. 28.00
1.00 7.0000 EA PL-DRAIN VENT PIPING 7.00
1.00 15.0000 EA PL-SEWER LINE 15.00
- ------------------------------------------------------------------------------
Special Notes and Comments
A FULL ACCEPTANCE TEST WILL BE REQUIRED FOR THIS HOOD AND
Separate Permits are required forelectrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes
null and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned
for a period of 180 days after the work has commenced,or if required inspectio'ns have not been requested within 180 days from the*
last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisioni
of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does I
not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construction.
S�n7
Date Print Name Signature of Contractor or Authorized Agent ature of Owner(if owner is builder)
T:Forms/Building Division/Building Permit
BUILDING PERMIT INSPECTION RECORD
0 PLEJSE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS—
-Building Inspections 417-4815 Electrical Inspections 417-4735
Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886
IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED.
POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE.
Inspection Type Date Accepted By Comments
FOUNDATION:
Footings
Sternwall
Foundation Drainage/Downspouts
Piers
Post Holes(Pole Bldgs.)
PLUMBING:
Under Floor/Slab
Rough-In
Water Line(Meter to Bldg)
Gas Line
Back Flow/Water
AIR SEAL:
Walls
Ceiling
FRAMING:
Joists/Girders/Under Floor
Shear Wall/Hold Downs
Walls/Roof/Ceiling
Drywall(Interior Braced Panel Only)
T-Bar
INSULATION:
Slab
Wall/Floor/Ceiling
MECHANICAL:
Heat Pump/Furnace/FAU/Ducts
Rough-In
Gas Line
Wood Stove/Pellet/Chimney
Commercial Hood/Ducts
MANUFACTURED HOMES:
Footing I Slab
Blocking&Hold Downs
jSkirting
PLANNING DEPT. Separate Permit#s SEPA:
Parking/Lighting ESA:
Landscaping ISHORELINE:
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY1 USE
Inspection Type Date Accepted By
Electrical 417-4735
Construction -R.W. PW I Engineering 417-4831
Fire 417-4653
Planning 417-4750
I Building 417-4815
CITY OF PORT ANGELES
it0;Q11MI DEPARTMENT OF COMMUNITY & ECONOMIC DEVELOPMENT- BUILDING DIVISION
W_ EW:=_V
321 EAST 5TH STREET, PORT ANGELES, WA 98362
Page 2
Application Number . . . . . 16-00000630 Date 6/03/16
Application pin number . . . 233380 REPORT SALES TAX
----------------------------------------------------------------------------
Special Notes and Comments on your state excise tax form
DUCT FIRE SUPPRESSION SYSTEM. THE TEST WILL INCLUDE A
BALLOON TEST, AS WELL AS A TEST OF THE FUSIBLE LINK, MANUAL to the City of Port Angeles
PULL STATION AND UTILITIES SHUT-OFF. (Location Coda 0502) 1
Electrical load calculations and electrical permits are
required.
fvj, Any modifications to the City's electrical facilities will
be at the customer'
s expense.
----------------------------------------------------------------------------
Other Fees . . . . . . . . . STATE SURCHARGE 4.50
--- ------- ------- ---- -------- ---
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 679.40 679.40 .00 .00
Plan Check Total 337.19 337.19 .00 .00
Other Fee Total 4.-.50 4.50 .00 .00
Grand Total 1021.0 1021.09 .00 .00
Separate Permits are required forelectrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes
null and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned
for a period of 180 days after.the work has commenced, or if required inspections have not been requested within 180 days from the
last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct.-All provisions
of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does;
not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construction.
Date Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder)
T:Forms/Building Division/Building Permit
BUILDING PERMIT INSPECTION RECORD
— PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS—
Building Inspections 417-4815 Electrical Inspections 417-4735
Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886
IT IS UNLAWFUL TO COVER,INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED.
POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE.
Inspection Type Date Accepted By Comments
FOUNDATION:
Footings
Stemwall
Foundation Drainage/Downspouts
Piers
Post Holes(Pole Bldgs.)
PLUMBING:
Under Floor/Slab
Rough-In
Water Line(Meter to Bldg)
Gas Line
Back Flow/Water
AIR SEAL:
Walls
Ceiling
FRAMING:
Joists/Girders/Under Floor
Shear Wall/Hold Downs
Walls/Roof I Ceiling
Drywall(interior Braced Panel Only)
T-Bar
INSULATION:
Slab
Wall/Floor/Ceiling
MECHANICAL:
Heat Pump/Furnace/FAU/Ducts
Rough-In
Gas Line
Wood Stove/Pellet/Chimney
Commercial Hood I Ducts
MANUFACTURED HOMES:
Footing/Slab
Blocking&Hold Downs
,Skirtng
PLANNING DEPT. Separate Permit#s SEPA:
Parking/Lighting [ESA:
S
Landscaping SHORELINE:
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY1 USE
Inspection Type Date Accepted By
Electrical 417-4735
Construction -R.W. PW I Engineering 417-4831
Fire 417-4653
Planning 417-4750
I Building 417-4815
THE For City Use
CITY OF ' RAT,
A Permit#
AS HINGTON, U. S.
Date Received:
321 E 51h Street Date Approved 4:7111-1 Ira
Port Angeles,WA 9836
P:360-417-4817 F:360-417-4711
Email:permits(@cityofpa.us BUILDING PERMIT APPLICATION
ProjectAddress: + ,-2- MAKIME PR,- 4PC>f,-r A&I 1�
5 hone: 0 4= -134
Primary Conta t: tN=A&- L e Email;
NamiZ C=AAC)0 &Kr CA0 I Phone :�360)
Property Mailing Address W Email
Owner 'a'a--2 DF�-
City State Z'
I �C4Z,--l- VC) .
Name Phone
-7- 2:2�JWJ,
1 :!-rEm)
Contractor Address F Email
& 1A 15tA ) k IT[
Information Cit;- State v%j A-
Contract r%Licens.e# —1-h V E.p Date:
T P I# Project Value: (materials and labor)
TWW-6�3SV3
Legal Description:
-0- Nblic El
Residential n;nPr,J-,1 Industrial
Permit Demolition 11 Fire El Repair El Reroof(tear off/lay over) 11
Classification For the following,fill out both pages of permit application:
(check New Construction D Exterior Remodel 11 Addition 11 Tenant Improvement 91
appropriate) Mechanical 11 Plumbing 1:3 Other El
Fire Sprinkler System ProposedT-fr—rigation System Proposed or Proposed Bathroo roposed Bedrooms
or Existing? Yes 0 No 0 1 Existing? Yes 0 No 0 1
In addition to standard hard copy submittals please send a PDF copy of all Stormwater plans and Engineering to
www.stormwaterO a.us
Project Description AJQ
&mmzp� �o-vt-,Iqzm* Vv . :11 fauu-b
V — -1. -
W STWA-2 . k t--fT--W&U rz-V t> I ZI-M�R 10- =P ]a I�N�
Is project in a Flood Zone: Yes 0 Nool Flood Zone Type:
If in a Flood Zone, what is the value of the structure before proposed improvement? $
I have read and completed the application and know it to be true and correct. I am authorized to apply for
this permit and understand that it is my responsibility to determine what permits are required and to
obtain permits prior to work. I understand that plan review fees are not refundable after review has
occurred. I understand that I will forfeit review fees if I withdraw the application before the permit is
issued. I understand that if the permit is not picked up/issued within 18o,days of submittal,the application
will be considered abandoned and the fees will be forfeited.
Date Print Name L-VLiVA-WJL'3 6� Signature Pe
Residential Structures
Existing Proposed Construction For Office Use
Area Descriptions(SQ FT) Floor area' Floor area $Value new area
Basement
First Floor
Second Floor
Covered Deck/Porch/Entry
Deck(over 30"or 2"floor)
Garage
Carport
Other(describe)
Area Totals
Commercial Structures
Area Descriptions(SQ FT) Existing Proposed Construction For Office Use
Floor area Floor area $Value new area
Existing Structure(s)
Proposed Addition
Tenant Improvement? V
Other work(describe)
Site Area Totals
Lot/Site Coverage Calculations
Lot Size(sq ft) Lot Coverage(sq ft)foot print of %Lot Coverage(Total lot cov lot size) Max Bldg Height
I all structures sq ft
Site Coverage(Sq Ft of all impervious) %of Site Coverage(total site cov�lot size)
Mechanical Fixtures
Indicate how many of each type of xtur to be installed or relocated as part of this project.
Air Handler I Size: # Haz/Non-Haz Piping Outlets:
Appliance Exhaust Fan # Heater(Suspended,Floor,Recessed wall) #
Boiler/Compressor Size: # Heating/Cooling appliance #
repair/alteration
Evaporative Cooler(attached,not # Pellet Stove/Wood-burning/Gas #
portable) Fireplace/Gas Stove/Gas Cook Stove/Misc.
Fuel Gas Piping #of Outlets: Ventilation Fan,single duct #
Furnace/Heat Pump/ Siz Ventilation System #
Forced Air Unit 1 #
Plumbing Fixtures
Indicate how many of each type of fixtu e to be installed or relocated
Plumbing Traps #
Water Heater #
Plumbing Vent piping # Medical gas piping #of Outlets:
Water Line # Fuel gas piping #of Outlets:
Sewer Line # Industrial waste pretreatment
interceptor(Grease Trap) Size
Other(describe):
T:\Forms\201S CED Form Updates\Building&Permitting\BP\Building Permit 201SO41S.docx
nil
rmpwmptw& Marine Dr
1st St CE�
ELI-
402
41a
41 409 A
112
N'-
tA
r-A
I 0&� J4 0'4'�'R
PL5hAY SH-MVING
y
so
.jagivis
;VVWIA29 N970M SMOCO Ngdo
jNMG
dO—N
VNVA TO
N
3NIWOVN.Joj
ADDMONAL INFO, FOR TYPE I HOOD ONLY:
I . GREA5E FILTERS 5HALL BE IN5TALLED AT MIN. 45 DEGREE ANGLE AND
EQUIPPED WITH DRIP TRAY AND GUTTER BENEATH LOWER EDGE OF FILTERS.
2. P15TANCE BETWEEN LOWEST EDGE OF GREA5E flLTER5 AND COOFJNG
5URPACE Of GRILL, FKYM AND EXPCOSED FLAME SHALL 13E NOT LE55 THAN
2 FT. EXP05ED CHARCOAL, CHARBROIL SHALL BE NOT LE55 THAN 3 112 FT.
3. TYPE I HOOD AND DUCT 5HALL HAVE CLEARANCE FROM COMBU5Tl5Lf
CON5TRUCTION OF:
UNPROTECTED PROTECTED W1 I HOUR FIRE RATED MATF-FJAL
HOOD MIN. 15 IN, HOOD MIN. 3 IN., DUCT MIN. 3 IN.
DUCT MIN. 15 IN.
4. HOOD5 LE55 THAN 12 IN. FROM CEILINGS OR WALLS 5HALL 13E fLA5HED
50LID.
5. ALL JOINT5 AND 5F-AM5 SHALL BE MADE WTTH CONTINUOU5 LIQUID-TfGHT
WELD OR BRAZE MADE ON THE EXTERNAL 5URFACE Of THE DUCT SY5TEM.
V113RATION INSULATION CONNECTOR MAY BE U5ED PROVIDED IT CON515T5
Of NOWCOMBUSTIBLE PACKJNG IN A METAL.5LEEVE JOINT.
G. CENTRIFUGAL PANS USED FOR D15CHARGING GREASE EXHAU5T 5HALL 13E
P05CTIONED IN A 130TTOM HORIZONTAL DISCHARGE POSIT'ION ONLY. A
DUCT THAT DIVEKT5 THE FAN D15CHARGE 5HALL NOT EXCEED 3 TIME5 THE
DIAMETER Of THE PAN OUTLET5 CONNECTED TO THE FAN OUTLFT. THE DUCT
5HALL BE PROVIDED W7TH AN ADEQUATE DRAIN OPENING AT THE LOWE5T
POINT TO PERMIT DRAINAGE Of GREASE TO A SUITABLE COLLECTION DEV15E.
MAKEUP AIR
1. APPLICANT SHALL PROVIDE MAKEUP AIR NOT LE55 THAN 5CM OF THE EXHAUST.
2.. MAKEUP AIR SYSTEM SHALL BE ELECTRICALLY INTERLOCKED WTnl THE E)(HAU5T
5Y5TI!M SUCH THAT THE MAKEUP AIR SYSTEM WILL OPERATE WHEN THE EXHAUST
SYSTEM 15 IN OPERATION.
3. 1 MAKEUP AIR SHALL BE PROVIDED BY A FAN OR MOTORIZED DAMPER OF 5urriciENT
CW-ACITY. WNDOW5 AND DOOR.OPENINGS SHALL NOT BE USED FOR THE PURP05E
OF PROVIDEING MAKEUP AIR.
4. If MORE THAN 2500 CFM SUPPLIED TO THE SPACE OTHER THAN THE HOOD.
PROVIDE HEATER CAPABLE OF HEATING MAKEUP AIR SUPPLIED TO THE SPACE TO
G5F.
DUCT ENCL05URE
I. DUCT5 PENETRATING A CEILING, WALL OR FLOOR, SHALL BE ENCLOSED IN A DUCT
ENCLOSURE FROM THE POINT OF PENETRATION TO THE OUTSIDE.
2. FOR CODE, COMPLIANCE PURPOSES, IT 15 ACCEPTABLE TO A55UME THAT DUCTS
PENETRATING CONCRETE, BRICKS OR STEEL CEILINGS, WALLS OR FLOORS SHALL
REQUIRE A 2-tIOUR FIRE-RE515TIVE DUCT ENCL05URE� AND FOR OTHERS, IT SHALL
13E I HOUR.
3. DUCT ENCLOSURES SHALL BE 5EPMTED FROM THE DUCT BY AT LEAST 3 AND NOT
MORE THAN 12-.
4. DUCT ENCL05URE SHALL BE SEALED AROUND THE DUCT AT THE POINT Of
PENETRATION AND VENTED TO THE ExTEKJOR THROUGH A WEATHER-MOTECTED
OPENING.
5. DUCT ENCLO5UFZ5 5HALl-,5ERV`f ONLY ONE KITCHEN EXHAUST DUCT.
G. TIGHT-FITTING ACCE55 OPENINGS SHALL BE PROVIDED AT EACH CLEANOUT DOOR-
ACZE55 ENCLOSURE DOOR5 SHALL HAVE A FIRE-RE515TANCE RATING EQUAL TO
THE ENCLOSURE.
J
�JDLIP? ar7a BrOP HOOD SHOP
P10,BOX 1808
CAMBRIDGE,OH 43725
FAX,800-716-1214
TOLL FREE: 800-715-1014
BOX MAKE-UP AIR CANOPY
www.hoodmart.com
General SpecificatIoM. soles@hoodmart.com
•Constructed of 18 gouge steel
4 7/7Z
•All joints are welded liquid tight, rT -Exhaust
without seams by an automatic
mig welder Riser
•Hoods are built In, accordance
with NFPA 96, NSF specifications,
and conforms to the U.L, 710 40— INCAN, CENY
standards supply
•Grease trough is rnade to
receive arease extracted by the Hanging
filters
Brackets
•Grease filtersore 20"baffle type, Length of Hood
they carry a U.L. listing and are
constructed of a light weight
aluminum steel -Make-Up
•',Each, grease trough Is equipped
I cup Air Chamber
with a stainless stee'
*Note: Factory does not cut holes 3" Air Gap
In hood Exhaust
Chamber
Available In:
•Deluxe: All Stainless Steel L-1 00W Pre-Wired Lights
•Hybdd: Front and Sides ore 2T Baffle Grease Filter
Stainless Steel and Top and Back
are Aluminized --Stainless Steel Grease Cup
•Economy: 'All Aluminized
ME�TL LISTED
r
,zX"ALIST HOODS
on COW.RJK4AL
COOKING SWIPMENT
VCHRMS To tFL sm no 0
MEMBEk
NjAe�Ajur Fan,FUNwd,32oo cFK I HP,CopuvicAm A2-G 12-3200 Pap I of 5
Used Restaurant Equipment Design Team Request A OuOte
4.
ALI 4=
Jca.O&JL.n aiiM
4JIM"AMW W111
CaptiveAire A2- SKU i i A"-*)
Requires Flashinq size: 3V' x 31:' (Sold Seoarateiy)
G12-3200 - Make-
Up Air Fan
FiLtered - 3200
CFM
A
U trie CaptiveAire._MseriesMU Spec Sheet7
DownloaJ L,
Download the CaptiveAire A-Series Spec Sheet'�!
DESCRIMON
NAnME7 N 11CWS
CAPTW.PA
CU.-law-va r"Urm"V". T,is-KV
A Series - Kodular Rooftop Filtered Make-up Air Fan
-if-he Air Handier Unit Is the heart of the moduiar fan
system. It is desiqned to deliver fresh outside make up
air jo,- installatt.-io,ris requiring i,requen' a r changes,
Handles hiaher air volurnes thar, standard unit-
A;
3200 CFNI
12" blower
Removable service doers on both sides
v,bravon lz;clakllon
High, efficiency m otors with a variable pitch met-or
Pulley, wt"i& Perm;)ts for system baiancing and fle!_
r L
ad3ustment
5/2/2016
Make-up Air Fan,Filtered, 3200 CFM, I HP, CAptiveAire A2-G12-3200 Page 2 of 5
• Adjustable drive sheaves (belt drive units only which
include pulleys and belts)
• Horizontal or down discharge
• 2" washable filters
• Inlet screen
• G90 galvanized steel
• Removable lid with spring loaded lid latches for full
easy accessibility to all components for inspection,
maintenance and cleaning
• Adjustable drive sheaves
• Disconnect switch
• Lifting points
• ETL Listed under file number 120029811-001 and
complies with UL705 and CSA C22.2, No. 113
Standards
C
ADDITIONAL INFORMATION
FEATURES Air Volume: 3200 CFN71 and 12" Blower
M A N U F ACT U P EP CaptiveAire
MATERIAL Ggo Galvanized Steel
MODEL NUMBER A2-G12-3200
SPEC SHEETS Download the CaptiveAire-AseriesMU
Spec Sheet=
Download the CaptiveAire A-Series
Spec Sheet"-
RELATED PRODUCTS
bnp://www.* -air-&is/capfivesire-a2-gl2-3200-- 5/2/2016
rvaumcm -
Accurex XRLJB--1 W 15-Exhaust Fan for Hood-3,M CFM-Commenial Kftchm Floo,... P*C I of 3
Accurex XRUB-180-15 - Exhaust Fan for Hood
- 3,250 CFM (Belt Drive - 208-230 Volts 3-PH -
1,5 HP
Not quite what you were looking for?Browse nxwe Commercial Kitchen Hood Systems
AI
:Exhaust Fan
• Manufacturer- ACCUREX
• Zesco It= No.:351-D-075
• Mfg.Item No.: XRUB-I W 15
• Usuafly Ships: 10 Days(Business Days)
List Price: $1,940.00 You Pay: $1,193.10 Fach You Save: $746.90(39%)
FREE SHIPPING(To Commercial Address)
Addtocart .1
Add to Favorites
http://www-msco.com/Accurex-XRUB-180-15-Exhaust-Fan-for-Ilood-3-250-CFM-pz351D... 5/2/2016
Accurcx XRUB-1 W15-Exhaust Fait for Hood-3,250 CFM-Commercial Kitchen Hoo... PW2of3
Be the first to review this item!
sm-RE
Description
Related Items(1)
PDFs (1)
Customer Reviews
Accwmx XRUB_1W15-ExIianst Pan for flood-3,M CFM
Belt Drive-209-230 Vohs 3-PH-1.5 HP
This Acc=:K hood=WUM f=W. 4 fan Teed of LOW fipm aod a volume of 23250 CFM at 0.8 in
wg. It has a 30" by 30" f�n base,a 1.5 FIP motor,and Lis UL/CUL 762 fiste&This fan has a belt drive,
the hinged base,curb seal,and heat baffle are attached,and it has a clean-out port and drain
connectiom Youll recerve free shippmg when tbis item is delivered to Ycor commercial address.
Please click the"related hems" above to order a roof curb to use with tins fan if you have a fig roof
Features:-
. Vt*T=b XRUB-I W 15-Exhaust Fan For Hood
- 3,250 CFK Fan Speed.- 1,000 Frpm.
- 1.5 HP
- ULICUL 762 Listed-Power Veniflatom For"Redaurant Exbaust Appliance"
- Adjustable MoW Pulley-Adjustable Motcw Plate
- Fan.Shaft Mounted In Ball Bearing Piltow Blocks-Beanngs Meet Or Exceed Ten4xMtm
Rating OfFan
- Switch,Nema-3r,Toggle,Junction Box Mounted And VtTired
- Attached Hinge Bmac And Curb Sad
- Clean-Out Port
- Attached Heat Baft And Dram Counection
Dimensions: 30"x 30"(BASE),30.38"DIA(FAN HOUSING),35.38"O.A.HT
ElechicaL- L51V-,20&230 Vohs,3Ph-&6,Amps
Warranty: I Yr Pau And Labor Warranty
F_
4 Reviews
(0)
(0)
(0)
(0)
Average Customer Review
0 Stars
Be the first to write a review for this item!
Product Spccifxafions�(PDF Format)
hftD://wwwzewo.caWAccurex-XRtM-IW15-Ex-hmust-Faa-f"-Hood-3-250-CFM-pz35!D,.. 5/2/2016
2M&S 7- 19 x4fr ExhamtHamiCamnen:hdKikhmEztmwtHmd
Your 10' x 48" Exhaust Hood Package -Includes:
Exhaust Fan (1pc)
Mounting Curb Wall / Roof (1pc)
Filters
Pre-Wired Light(s)
Stainless Grease Cup(s)
Hanging Brackets
See more ggbaUd hood pjgb= on Phyterest-
10" x 48" Exhaust Hood Package Features
,t All hoods are constructed of 18 gauge steel
All joints are welded liquid tight, without seams by an automatic Wire fed mig welder
All hoods are built in accordance to NFPA 96, NSF specifications, & U.L 710
specifications
Grease trough is made to receive grease extracted by filters
Grease filters are baffle type (2W' wide), U.L listed, made of Ught weight aluminum steel
A stainless steel cup attaches to the tray that runs beneath the entire length of the hood
1W x 48" Waust Hood Systein OveMew
Commercial kitchen exhaust hoods from Hoodmartcom are the most important and most
commonly underappreciated part of your restaurant and the ventilation system that
connects to it. Our 19 x 48- exhaust hood comes equipped with high-powered fans or
blowers remove odors and improve the indoor air quality inside your kitchen. Commercial
kitchen fans also remove moristure� which can increase the level of humidity. Of course we
all know that high humidity can cause mold, mildew and bacteria growth which ultimately
results in major health code violations.
Veryted kitchen fans help to maintain proper indoor air quality. They also help remove
pollutants, cooking odors, moisture and' grease from the restaurarTt's kitchen. Commercial
kitchen range hoods must deal effectively with grease to expel this odor. One reason that
commercial kitchen fans are so powerful is that they must maintain the proper velocity to
draw all cooking contaminants into the hood. If this is not accomplished properly, grease
gets.deposited throughout the kitchen, creat.ing a severe fire hazard and the risk of a
3/4
2M&&Z W x Ar Eft"HM4 C4nWMwdd KrIdW Embast Hood
kitchen fire. This is how a commercial kitchen exhaust hood differs drastically from a
residential exhaust hood.
Restaurant kitchen fans are important to maintaining indoor air quality. If a commercial
kitchen exhaust hood is property sized, it Will help ensure that 'proper breathing' of the
restaurant kitchen is achieved. These restauraryt and commercial hood systems must be
property installed by certified technicians and-they also must be perf6unance-tested for
pmW ventilation. The many advafftages of these commercial kitchen exhaust hoods make
them a popular choice of professional installers.
Get a quote today for a 19-x 48" exhaust hood for your commercial- kitchen.
Hw Can We He I p You?
Nam
Phom
Get M_6_ r e- -Infb----
PastWZip Code
HoodMart vvill not share information you proVide to any outside
parties,
Customer ftviews Write A Review
& Cgmmercial Kilghen Ventilation STORE
0 HOODS
* Exhaust Hoods
* Makeuj2-Air Hoods
* Mentima Hoods
e !Cg0=iW Hggds
& Pizza Hoods
0 FANS
w Exhay5t Fans
o MakwAr Eana
0 FIRE
0 Fim %WD019go
0 SPEC SHEETS
e Spec 5heets (PDF)
0 QUESTIONS ?
* Conte-K-1 Us
------ 44
9SMUSWIFT
2+ 1
YEAR
"MITED WARRANIV
J ZA
The Saniswift drain pump is used to pump gray water away from a variety of fixtures in residential applications.
The system is able to discharge the waste up to 14 feet vertical and/or 140 feet horizontal.
* Discharges the waste through a V rigid pipe. A non-return valve is included on the discharge fitting assembly provided with the system.
* Has been designed with a VA"vent connection on top of the lid. All plumbing codes require connection to a vent system. Either inlet located
on top of the housing can be used for the vent or as an inlet. Please note that the vent system should be a two-way air vent as air needs to
freely flow both ways. Note:The use of mechanical vents, air admittance valves or similar devices is not permitted.
* Discharges gray water from a kitchen sink,shower,dishwasher,washing machine(indirect connection via laundry sink).The gray water will
drain into the system via three 11/2"inlets,two low inlets(with built-in check valves)on either side of the housing and one on top of the enclosure.
I �1747 f- 7 PF- lGrade
r
0
TECHNICAL SPECIFICATIONS
Pump type:Drain pump
Electrical: 120 V—60 Hz/4.5 Amps(Max)
Motor:0.3 HP oil-filled thermally protected motor
Capacitor rating:30 microfarad
Operating Temperature: 140 F0 Max.
Power cord length:48 inches
Noise level:s 44 dBA(Lp) (measured at 3 ft.)
SANISWIFT PART NO. 021 1 C10
13UW 16C
Discharge pipe diainet6r:
Discharge rate at 14 ft. 18 GPM
Discharge rate at 3 ft:24.GPM 21
Shut-off head:25 ft. Eiia
Normal running time: 3-5.sec6nds.(short bursts)
Capacity:2.75 gallons
inlets: 11/2 (sides),,11/2"vent:(top)
Method of activation: Pressure switch,circuit board 11
Shower/bathtub baseheight.-6"-811min. 9
Weight- 13 lbs.
Certifying agencies:CSA(]PC, NSPC)
Recommended accessories:Descaler
Connections:Sink,shower,washing.machine(indirect),
dishwasher, laundry sink,etc. 3
I OX'
ly",
14
8/4' 15
16
5
9.
22 18
PLEASE CALL US TOLL-FREE AT 800-571-8191 (US)/800-363-5874(CDN)
TO PURCHASE PARTS REFERENCED ABOVE
AN EASY SOLUTION FOR A REMOTE
LAUNDRY ROOM INSTALLATION OR FOR
ANY GRAY WATER APPLICATION
12
Powerful and economical with a compact design and
multiple inlets which makes it perfect for installations
anywhere you can imagine.
The perfect quiet solution designed with low drain inlets
which facilitate the installation of a shower in residential o N"drain
applications. Built-in check valves prevent any backup Min.6-8' oN"draln
into the connecting fixtures. P
<
Enjoy your laundry room addifion with help from Saniflo!
Saniswift Gray Water Pump Page I of 3
Advanced Search
Stol*
WE KNOW SANIFLO!
Free Slow Close Seat & Shipping With Kits
Tax Free Shopping, Expert Support
Call Us at 866-658-0505 or 603-379-8oll
Home Shopping Cart Sign In Register Contact Us
Saniflo Bathroom Kits Saniflo MaceratorS & Grinders Saniflo Toilets Gray Waier Pumps Accesso,ies
Our Products >> Saniflo Saniswift Shopping Cart
Saniflo Saniswift (0)
Possible connections
Interest Free
V "Ink V Shower Financing!
'Nashing?,lachine(indirect e' Dishwasher
connection� Check out the
Interest Free
Financing fironi
11 too 14C't Paypal Credit at the
age
Click To Enlarge
'I lie Sa.niflo Sanisivift is a gray water pump that is suitable for use ill a basement apartlnent Or
Manufacturer's Product anywhere where additional fixtures are wanted. the Saiiiswiftwill pump the gray How do they
Number:021
water wastL awav from a varietv of sources such as�a kitchen sink,laundry sirik,washing work.)
maclune(indirect connection),dishwasher,bar silik-,etc.
1 reviews The modern stvie of the Saniflo Saniswift punip prevails over other bul1v relics.Tlie Sanitlo This is a frequent
Saniswift is a powerful and o-onomical pump with a compact, contemporary deF1'gn. With question from many
unprecedented performance and features, the Saniflo Saniswilt grav water pump is of our DIY customers,
unnuitched ill it's class. one which is best
answered by the
In addition t.o asink,the Sailiswilt pump will also accept and discharge the grav water froin a short video at the
vaTletv of other sailitary fixtures such as:a kitchen sink,a shower,a urinal. bottom of our site.
To get an example of
For more productspecifications and installation instruction,;for the Saniflo Saniswift pump an installation check
pleme visit: out this video I h i,
littp://w%-w.sai-&Io.ckim/hoiiie,t)wners/sfa-prodtict-Iiiie/puinps-tor-kitcheii-and-laundry- Old ffouse'v ideo
room/
Dimensions iHeghtx hitih x 8-214'X 9'X,0- FAQ's/Answers
Depti
If I call who wil I I
Dscharge PIN Diamilter i in be talking with? You
will speak with Mark
Ncharge Rate at A igpml� 24 or Erin. After hours
calls get forwarded
Cacharge Rate at Mv,Heiglit to Mark, he does
ig have kids but will
pick up or return
EWiricai Sjpp�,iV, your call as$0011 a,,;
he can!(We like to
Horizontal Discha,ge�ftj 140 keep In i m oil his fees)
*We Know Saniflo!
H,rgepcwer 01. We are a Factory
Authorized stocking
4lax.Amperage f distributor,unlike
inany people gelling
Jjaxj,njm7em;eratu;e,:F 140 online we actually
have our stock in our
hin 'rayr1h,-all on 4ii,iuval I'A fi— facility,
http://www.saniflostore.com/Saniflo-Saniswift-02 Lhtm 5/2/2016