HomeMy WebLinkAbout606 Milwaukee Drive Address:
606 Milwaukee Drive
PREPARED 8/18/14, 13:06:55 INSPECTION TICKET PAGE 1
CITY OF PORT ANGELES INSPECTOR: JAMES LIERLY DATE 8/18/14
------------------------------------------------------------------------------------------------
ADDRESS 606 MILWAUKEE DR SUBDIV:
CONTRACTOR : PHONE : -
OWNER HALBERG, SHWAN PHONE ; (360) 461-4379
PARCEL 06-30-00-1-0-3910-0000-
APPL NUMBER: 13-00001169 RES ADDITION
------------------------------------------------------------------------------------------------
PERMIT: BPR 00 BUILDING PERMIT - RESIDENTIAL
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
BL1 01 12/18/13 PB BLDG FOUNDATION FOOTING
12/19/13 AP December 18, 2013 10:42:21 AM pbarthol.
alex 460-4248
December 19, 2013 10:00:21 AM pbarthol.
January 7, 2014 8:36:39 AM pbarthol.
BL2 01 1/07/14 PB BLDG FOUNDATION STEM WALL
1/08/14 AP January 7, 2014 8:36:58 AM pbarthol.
Alex 460-4248
January 8, 2014 10:05:07 AM pbarthol-
BL9 01 4/04/14 JLL BLDG SHEARWALL
4/07/14 AP April 4, 2014 11:04:27 AM pbarthol.
Ron 461-4644
April 7, 2014 10:10:42 AM jlierly.
BL3 01 S/29/14 JLL BLDG FRAMING
5/29/14 DA May 29, 2014 9:06:03 AM jlierly.
ron 461-4644
May 29, 2014 2:10:00 PM jlierly.
Framing is ok just need to call electrical rough in first
before frame can be approved/jll
BAIR 01 6/12/14 JLL BLDG AIR SEAL
6/12/14 AP June 12, 2014 10:11:46 AM pbarthol.
June 12, 2014 4:17:14 PM jlierly.
BLI 01 6/12/14 JLL BLDG INSULATION
6/12/14 CA June 12, 2014 10:11:23 AM pbarthol.
June 12, 2014 4:16:34 PM jlierly.
This inspection was needed the following day will
reschedule/jll
BL3 02 6/12/14 JLL BLDG FRAMING
6/12/14 AP June 12, 2014 10:11:04 AM pbarthol-
June 12, 2014 4:17:14 PM jlierly.
BLI 02 6/16/14 JLL BLDG INSULATION
6/16/14 AP June 12, 2014 4:18:52 PM jlierly.
RON
June 13, 2014 1:31:09 PM jlierly.
Contractor called and said they brought the wrong 'i'nsulation
and wanted to push the inspection back till Monday/�jll
June 1G, 2014 4:02:11 PM jlierly.
BL99 01 8/18/14 JLV—\ BLDG FINAL
August 18, 2014 8:58:22 AM pbarthol.
Ron 461-4G44
--------------------- -------------------------------------------------------------------
PERMIT: ME oo KEcHANir-AL'ARMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
ME1 01 6/12/14 JLL MECHANICAL ROUGH-IN
----------------------------------- CONTINUED ONTO NEXT PAGE -----------------------------------
PREPARED 8/18/14, 13:06:SS INSPECTION TICKET PACE 2
CITY OF PORT ANGELES INSPECTOR: JAMES LIERLY DATE 8/18/14
------------------------------------------------------------------------------------------------
ADDRESS . : 606 MILWAUKEE DR SUBDIV:
CONTRACTOR : -PHONE :
OWNER HALBERG, SHWAN PHONE : (360) 461-4379
PARCEL 06-30-00-1-0-3910-0000-
APPL NUMBER: 13-00001169 RES ADDITION
------------------------------------------------------------------------------------------------
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
6/12/14 AP June 12, 2014 10:12:00 AM pbarthol.
June 12, 2014 4:17:14 PM jlierly.
ME99 01 8/18/14 MECHANICAL FINAL
August 18, 2014 8:58:39 AM pbarthol.
Ron 461-4644
--------------------- -------------------------------------------------------------------
PERMIT: PL 00 PLUMBING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
PL2 01 5/29/14 JLL PLUMBING ROUGH-IN
5/29/14 A�, May 29, 2014 9:06:29 AM jlierly.
M.y 29, 2014 2:10:51 PM ilierly.
PL99 01 8/18/14 PLUMBING FINAL
August 18, 2014 8:59:04 AM pbarthol.
Ron 461-4644
---------------------- --------- COMMENTS AND NOTES --------------------------------------
CITY OF PORT ANGELES
DEPARTMENT OF COMMUNITY& ECONOMIC DEVELOPMENT- BUILDING DIVISION
321 EAST 5TH STREET, PORT ANGELES, WA 98362
Application Number . . . . . 13-00001IG9 Date 10/24/13
Application pin number . . . 7GG921
Property Address . . . . . . GOG MILWAUKEE DR
ASSESSOR PARCEL NUMBER: 06-30-00-1-0-3910-0000- REPORT SALES TAX
Application type description RES ADDITION
Subdivision Name . . . . . . on your state excise tax form
Property Use . . . . . . . . to the City of Port Angeles
Property Zoning . . . . . . . RS9 RESDNTL SINGLE FAMILY
Application valuation . . . . 44G47 (Location Code 0502)
----------------------------------------------------------------------------
Application desc
GARAGE/DECK/CARPORT/MASTER BATH ADDITION
----------------------------------------------------------------------------
Owner Contractor
------------------------ ------------------------
HALBERG, SHWAN OWNER
131G WEST 5TH STREET
PORT ANGELES WA 983G3
(360) 461-4379
----------------------------------------------------------------------------
Permit . . . . . . BUILDING PERMIT -RESIDENTIAL
Additional desc . . GARAGE/DECK/CARPORT/MSTR BATH
Permit Fee , . . . G19.75 Plan Check Fee 402.84
Issue Date . . . . 10/24/13 Valuation . . . . 44647
Expiration Date 4/22/14 .
Qty Unit Charge Per Extension
BASE FEE 417.75
20.00 10.1000 THOU BL-25,001-50K (10.10 PER K) 202.00
--------------------------------------------------------7-------------------
Permit . . . . . . MECHANICAL PERMIT
Additional desc . . MSTR BATH/GARAGE/DECK
Permit Fee . . . . 57.25 Plan Check Fee .00
Issue Date . . . . 10/24/13 valuation . . . . 0
Expiration Date 4/22/14
.Qty Unit Charge Per Extension
BASE FEE 50.00
1.00 7.2500 EA ME-VENT FAN (SINGLE DUCT) 7.25
----------------------------------------------------------------------------
Permit . . . . . . PLUMBING PERMIT
Additional desc MASTER BATH ADDITION
Permit Fee . . . . 92.00 Plan Check Fee .00
Issue Date . . . . 10/24/13 Valuation . . . . 0
Expiration Date 4/22/14
Qty Unit Charge Per Extension
BASE FEE 50.00
3.00 7.0000 EA PL-PLUMBING TRAP 21.00
1.00 7.0000 EA PL-WATER LINE 7.00
2.00 7.0000 EA PL-DRAIN VENT PIPING 14.00
----------------------------------------------------------------------------
Special No tes and Comments
October 24, 2013 10:40:11 AM sroberds.
Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes
null and void if work or construction authorized is7not commenced within,180 days,if construction or work is suspended or abandoned
for a period of 180 days after the work has commenced, or if required'inspecti6ns have not been requested within 180 days from the
last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions
of laws,and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does
not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construction.
(0-
Date Print Name Signature of Contractor or Authorized Agent Sig ature ner(if owner is builder)
T:Fo�ms/Building Division/Building Permit
BUILDING PERMIT INSPECTION RECORD
PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS—
Building Inspections. 417-4815 Electrical Inspections 417-4735
Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886
IT IS UNLAWFUL,TO COVER, INSULATE OR CONC�Al-ANY WORK BEFORE INSPECTED AND ACCEPTED.
POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE.
Inspection Type Date Accepted By Comments
FOUNDATION:
Footings
Stemwall
Foundation Drainage/Downspouts
Piers
Post Holes(Pole Bldgs.)
PLUMBING:
Under Floor I Slab
Rough-in
Water Line(Meter to Bldg)
Gas Line
Back Flow/Water FINAL Date Accepted by
AIR SEAL:
Walls
Ceiling
FRAMING:
Joists/Girders/Under Floor
Shear Wall/Hold Downs
Walls/Roof/Ceiling
Drywall(Interior Braced Panel Only)
T-Bar
INSULATION:
Slab
Wall/Floor/Ceiling
MECHANICAL:
Heat Pump/Furnace/FAU/Ducts
Rough-In
Gas Line
Wood Stove/Pellet/Chimney
Commercial Hood/Ducts FINAL Date Accepted by
MANUFACTURED HOMES:
.Footing/Slab
1131ocking&Hold Downs
ISkirting
PLANNING DEPT. Separate Permit#s SEPA:
Parking I Lighting ESA:
Landscaping ISHORELINE:
FINAL INSPECTIONS REQVIREQ PRIOR TO OCCUPANCY1 USE
Inspection Type Date Accepted By
Electrical 417-4735
Construction-R.W. PW Engineering 417-4831
Fire 417-4653
Planning 417-4750
Building 417-4815
T:Forms/Building Division/Building Permit
CITY OF PORT ANGELES
DEPARTMENT OF COMMUNITY& ECONOMIC DEVELOPMENT- BUILDING DIVISION
321 EAST 5TH STREET, PORT ANGELES,WA 98362
Page 2
Application Number . . . . . 13-00001169 Date 10/24/13
Application pin number . . . 766921
---------------------------------------------------------------------------- REPORT SALES TAX
Special Notes and Comments
Small addition/new garage in RS-9 for total of 9% lot cov on your state excise tax form
and 16% site cov. Front yd setback to 101 approved per VAR to the City of Port Angeles
03-09B along Milwaukee Dr.
Electrical load calculations and electrical permits are (Location Code 0502)
required.
Temp erosion control and surface restoration responsibility
of applicant' No attachment to sanitary sewer of stormwater
roof leaders, foundation drains, yard drains, or any other
CSO contribution is allowed. Use existing driveway opening
for site access.
Consider applying for the City Green Infrastructure Rebate
of up to $500.00 towards the materials to install rain
garden to control roof and driveway runoff. Contact Jonathan
Boehme at 360 417-4811
----------------------------------------------------------------------------
Other Fees . . . . . . . . .1� STATE SURCHARGE 4.50
-----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 769.00 769.00 .00 .00
Plan Check Total 402.84 402.84 .00 .00
Other Fee Total 4.50 4.50 � : .00 .00
Grand Total 1176.-34 1176.34 � .00 .00
Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes
null and void if work or construction authorized is:not commenced within.180 days,if construction or.work.is suspended or abandoned
for a period of 180 days after the work has.commenced,or if require-d:insp'e ctidns have' not been.requested within 180 days from the
last inspection. I hereby certffy that I have read and examined this application and know the sameto.be true and correct. All provisions
of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does
not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the.performance of
construction.
Date Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder)
T:Forms/Building Division/Building Permit
BUILDING PERMIT INSPECTION RECORD
PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS—
Building Inspections. 417-4815 Electrical Inspections 417-4735
Public Works Utilities 4174831 Backflow Prevention Inspections 417-4886
IT IS UNLAWFUL TO COVER,INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED.
POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE.
Inspection Type Date Accepted By Comments
FOUNDATION:
Footings
Stemwall
Foundation Drainage/Downspouts
Piers
Post Holes(Pole Bldgs.)
PLUMBING:
Under Floor I Slab
Rough-in
Water Line(Meter to Bldg)
Gas Line
Back Flow/Water FINAL Date Accepted by
AIR SEAL:
Walls
Ceiling
FRAMING:
Joists/Girders/Under Floor
Shear Wall/Hold Downs
Walls/Roof/Ceiling
Drywall(interior Braced Panel Only)
T-Bar
INSULATION:
Slab
Wall/Floor/Ceiling
MECHANICAL:
Heat Pump/Furnace I FAU/Ducts
Rough-in
Gas Line
Wood Stove/Pellet/Chimney
Commercial Hood/Ducts FINAL Date Accepted by
MANUFACTURED HOMES:
Footing/Slab
Blocking&Hold Downs
Skirting
PLANNING DEPT. Separate Permit#s SEPA:
Parking/Lighting ESA:
Landscaping ISHORELINE:
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY1 USE
Inspection Type Date Accepted By
Electrical 417-4735
Construction-R.W. PW I Engineering 417-4831
Fire 417-4653
Planning 417-4750
Building 417-4815
T:Forms/Building Division/Building Permit
THE For City Use
F
CITY POJLA.X
OF A _�LE S Permit# J
W A S H I N G T 0 N , U. S.
Date Received: ('0—'21—
3 2 1 E 51h Street Date Appro"vQed! al 6
Port Angeles,WA 9836
P:360-417-4817 F: 360-417-4711
Email: permits0cityofVa.us BUILDING PERMIT APPLICATION
ProjectAddress: 60(,
3
Phone: (-o #71-3a91/5
Primary Contact: m il.
Email: 1 !� 66, 1 CO
Name
C�7 Phone
S<-C1--\ A- ?(, ()' q� ( (0-7
Property Maili Adduss Email
Owner nt VV\ C�7
City P,�4 State ti Zip
Name Phone
—Cont-rac-tor— Address Email
Information city State Zi
Contractor License# Exp.Date:
tin� Ta
Legal Description: Zoni g: x Parcel# Project Value: (materials and labor)
DL-�00(' 10�"Ilo -17
$ &�L
Residential 7ff Commercial 0 Industrial Public El
Permit Demolition 0 Fire El Repair El Reroof(tear off/lay over) 11
Classification For the followine. fill out both Dages of permit application:
(check New Construction El Exterior Remodel Z Addition 11 Tenant Improvement
appropriate) I Mechanical El Plumbing El Other El
Will a fire sprinkler system be installed Ir-rigation System? Proposed Bathrooms Proposed Bedrooms
or modified? Yes 11 No ,9 Yes 0 NoZ[
Project Description
Is project in a Flood Zone: Yes El Nop Flood Zone Type:
If in a Flood Zone, what is the value of the structure before proposed improvement? $
I have read and completed the application and know it to be true and correct. I am authorized to apply for
this permit and understand that it is my responsibility to determine what permits are required and to
obtain permits prior to work. I understand that plan review fees are not refundable after review has
occurred. I understand that I will forfeit review fees if I withdraw the application before the permit is
issued. I understand that if the permit is not picked up/issued within 18o days of submittal,the application
will be considered abandoned and the fees will be forfeited.
Date Print Name6-r--c) [-("16 Signature
Residential Structures
For Office Use
Area Description(SQ FT) Existing Proposed ss value
Basement
First Floor '00<�
Second Floor
Covered Deck/Porch/Entry
Deck(over 30"or2'd floor)
Garage 0
Carport 0 022
Other(describe)
Area Totals
Commercial Structures
Proposed For Office Use
Area Descriptions(SQ FT) Existing Proposed ss Value
-Existing-Structure-W
Proposed Addition
Tenant Improvement?
Other work(describe)
Site Area Totals
Lot/Site Coverage Calculations
Lot Size (sq ft) Lot Coverage (sq ft) %Lot Coverage (Total lot coverage+lot size)
YI-> �1( 19 C> Wq0' ;0 ,--�'Ll.
Site Coverage (Sq Ft of all impervious) %of Site Coverage (total site coverage+lot size)
-�, 'g'Z 5- ! - /C -'�a
Mechanical Fixtures
Indicate how many of each type of fixture to be installed or relocated as part of this project.
Air Handle Size: # Haz/Non-Haz Piping Outlets:
Appliance Exhaust Fan # Heater(Suspended,Floor,Recessed wall) #
Boiler/Compressor Size: # Heating/Cooling appliance #
repair/alte ation
Evaporative Cooler(attached, not # Pellet Stove/Wood-burniing/Gas #
portable) as Stove/Gas Cook Stove/Misc.
Fuel Gas Piping #of Outlets: Ventilation Fan,single duct #
F Forced Air Unit # Ventilation System #
urnace/Heat Pump
Plumbing Fixtures
Indicate how many of each type of fixtu e to be installed or relocated
Plumbing Traps # Fuel gas piping. #of Outlets:
Water Heater # Medical gas piping #of Outlets:
Water Line # Plumbing Vent piping #
Sewer Line # Industrial waste pretreatment
interceptor(Grease Trap) Size
Other(describe):
T:\BUILDING\APPLICATION FORMS\Current BP Application\Building Permit 4-17-13.docx
Prescriptive Energy Code Compliance for All Climate Zones in Washington
Project Information Contact Information
This project will use the requirements of the Prescriptive Path below and incorporate the
the minimum values listed. In addition, based on the size of the structure, the appropriate
number of additional credits are checked as chosen by the permit applicant.
Authorized Representative Date to
L
Tkil Climate Zones
R-Va.lue' U-Factor a
Fenestration U-Factor b n/a 0.30
Skylight U-Factor n/a 0.50
Glazed Fenestration SHG Cb., n/a n/a
Ceiling 4Y 0.026
Wood Frame Wallg-�" 21 int 0.056
Mass Wall R-Value' 21/2 1 h 0.056
Floor 301 0.029
Below Grade Wa llc,k J 10/15/21 int 0.042
Slab d R-Value& Depth 1 10, 2 ft n/a
*Table R402.1.1 and Table R402.1.3 Footnotes included on Page 2.
Each dwelling unit in one and two-family dwellings and townhouses,as defined in Section 101.2 of the
International Residential Code shall comply with sufficient options from Table R406.2 so as to achieve the
following minimum number of credits:
'*1. Small Dwelling Unit: 0.5 points
Dwelling units less than 1500 square feet in conditioned floor area with less than 300 square feet of fenestration
area. Additions to existing building that are less than 750 square feet of heated floor area.
F-]2. Medium Dwelling Unit: 1.5 points
All dwelling units that are not included in#1 or#3, including additions over 750 square feet.
F-13. Large Dwelling Unit: 2.5 points
Dwelling units exceeding 5000 square feet of conditioned floor area.
Table R406.2 Summary
Option Description Credit(s)
1 a Efficient Building Envelope 1 a 0.5
1 b Efficient Building Envelope 1 b 1.0 F-1
Ic Efficient Building Envelope 1c 2.0
2a Air Leakage Control and Efficient Ventilation 2a 0.5
2b Air Leakage Control and Efficient Ventilation 2b 1.0 F1
2c Air Leakage Control and Efficient Ventilation 2c 1.5 F-1
3a High Efficiency HVAC 3a 0.5 El
3b High Efficiency HVAC 315 1.0 1-1
3c High Efficiency HVAC 3c 2.0 F-1
3d High Efficiency HVAC 3d 1.0
4 High Efficiency HVAC Distribution System 1.0
5a Efficient Water Heating 0.5 F-1
5b Efficient Water Heating 1.5 1-1
Renewable Electric Energy 0.5 *1200 kwh 0.0
Total Credits 0.00
*Please refer to Table R406,2 for complete option descriptions
http://www.energy.wsu.edu/Documents/2012�/�2ORes�/�2OEnergy.pd
Table R402.1.1 Footnotes
For SI: 1 foot .= 304.8 mm, ci .= continuous insulation, int .= intermediate framing.
a R-values are minimums. U-factors and SHGC are maximums. When insulation is installed in a cavity which is
less than the label or design thickness of the insulation, the compressed R-value of the insulation from
Appendix Table A101.4 shall not be less than the R-value specified in the table.
b The fenestration U-factor column excludes skylights. The SHGC column applies to all glazed fenestration.
Exception: Skylights may be excluded from glazed fenestration SHGC requirements in Climate Zones 1
through 3 where the SHGC for such skylights does not exceed 0.30.
C 11 10/15/21.+TB" means R-10 continuous insulation on the exterior of the wall, or R-15 on the continuous
insulation on the interior of the wall, or R-21 cavity insulation plus a thermal break between the slab and the
basement wall at the interior of the basement wall. "10/15/21.+TB" shall be permitted to be met with R-13
cavity insulation on the interior of the basement wall plus R-5 continuous insulation on the interior or
exterior of the wall. "10/13" means R-10 continuous insulation on the interior or exterior of the home or R-
13 cavity insulation at the interior of the basement wall. 713" means thermal break between floor slab and
basement wall.
d R-10 continuous insulation is required under heated slab on grade floors. See R402.2.9.1.
e There are no SHGC requirements in the Marine Zone.
f Basement wall insulation is not required in warm-humid locations as defined by Figure R301.1 and Table
R301.1.
Reserved.
h First value is cavity insulation, second is continuous insulation or insulated siding, so "13.+5" means R-13
cavity insulation plus R-5 continuous insulation or insulated siding. If structural sheathing covers 40 percent
or less of the exterior, continuous insulation R-value shall be permitted to be reduced by no more than R-3 in
the locations where structural sheathing is used to maintain a consistent total sheathing thickness.
The second R-value applies when more than half the insulation is on the interior of the mass wall.
For single rafter- or joist-vaulted ceilings, the insulation may be reduced to R-38.
k Int. (intermediate framing) denotes standard framing 16 inches on center with headers insulated with a
minimum of R-10 insulation.
I Log and solid timber walls with a minimum average thickness of 3.5 inches are exempt from this insulation
requirement.
Table R402.1.3 Footnote
a Nonfenestration U-factors shall be obtained from measurement, calculation or an approved source or as
specified in Section R402.1.3.
PQRT-ANGELIES
W A S H I N G T 0 N, U. -S. A. NOV 10 2005
C'TYOFPORTAN ELES
PUBLI WORKS UTILITI.ES DE RT'MENT Dept.ofCommunit Dev lo ment
November 9, 2005
Mr. Sean Halberg
1507 East Beach Road .
Port Angeles, WA 9836'
RE: Milwaukee Drive Improvements
Dear Sean:
Thank You for your left6rof November 7 2005 regarding the sidewalk
improvements required for your n4r residence. We
er
regarding the extent of frontage improvements that would
had met with you earli
new residence. Normally they would have been required be required for your
frontage of app for the full
extent of your
roximately 414 feet. Due to the shape of the lot
for a boundary adjustmen and the potential
t with the property to the north and east the frontage
improvement requirements were reduced to just beyond your proposed building
with a LID agreement for the re
no protest mainder. With your present driveway 1�3
location this reduced your frontage requirements by 174 feet to approximatel
240 feet.-U i
sing Your construction cost esti
y
mates ($�l.30/L.F.)this reduction will
save you $5,446 plus the cost of pa Vement widening for 174 feet.
K."
The sidewalk improvements were cleady noted on your buil
ding permit. You
could have appealed the requirements when the permit
appealpe was issued, but the
Hod has passed. The street
requirements are fromthe City's Urban
Services for Street and Access Requirements(PAMC 18-08.040D,ordinance '.
2857 adopted 2/17/95)that states "De
Yelopment that creates pedestrian
on any arterial streets and other streets id.entified in the CftYs transportation plan (b
traffic
as school-walking routes shall include
pedestrian sidewalks." Milwaukee Drive is
an arterial and the sidewalk improvern
ents areTequired. In addition Milwaukee
Drive is a.part of the waterfront trail system.
e -
Please call if you have questions.
Sin&re y,
..........
Gary W. K
Y
Deputy Director of Public Works/City Engineer
cc:Genn Cut*,Jim Lierly Trenia Funston
MMMENGINEEMBuild'
ing C0:spmdence\HaIberS wwaukee Side"Jk.doc
321 EAST FIFTH STREET *_P 0. BOX
If 50 0 PORT ANGELES, WA 98362-0217
PHONE: 36,0-417-4805 0 FAX: 360-417-4542 TTY. 360-417-4645
E-MAIL: PUb1iCW0rksCcDcjty0fpa.US
le
I IfIt,,q, Pold
"I GRADE - 14%GRADE
3%GRADE 7Z GRADE
SECTIN
59
SECTIDN D-D
SECTIDN E-E
7'—112
—----------------T r
L -J24
Ln
--------------------------------
------------------—-—
O""'s G R Arj'-::.
COINCRET� SUBI
-OK,�,IAUED FUL
S!-L;�E 10 6001�
El
L -J 30
---------------------------------
L -----------------------------
VERIFY LOCATION OF
TOP OF BLUFF
fPOA,r
10-0 st C/(
fT.
PROPOSED
RESIDENCE
Af 7j,
59,
414.56,
C-1
4 N
CURB CUT PER
CITY OF PORT ANGELES
REQUIRMENTS
APPROXIMATE LINE OF TOP
OF MARINE 13WFF
BLUFF SETBACK LINE P_ER
GEOTECH REPORT
SETBACK FOR ACCESSORY STRUCTURES
BUILDING SETBACK LINES
PC
ZONIN CODE
144.5 REQUESTED ACK UNES
N
PROPERTY Ll
<4
EXISTIN&EDGE-Or 'P,
_,AVEMEJV-r'
------------- +
4p
0�
Wz,
07 -�,V%�
A-w
k� R
t t S,
P
-Iq
14
3850 PR 3068 3850
SH FULL LITE SH
4050 4106:1
TEMP SLII�l:! SH SH
3050 L /oso
SH GREAT ROOM >H
i sos T4050 41068
BEDROOM EMP —SLIDER
SHOWER
C__ 4050
3 3050 S.
AO G IH
TNP
0 0
KITCHEN BATHROOM
F C SET
3030
S.
2036 2036 2036 4 30
C
=pl ATH' TflsE
ASE CASE CASE so
H
3850 PR 3068 3850
SH FULL LITE SH
4a5O 4050
SH 4 50 4050
SH SH SH
4050 3020
SH I FAMILY ROOM SH 06B
BEDROOM BEDROOM ULL
LITE
306
4030 2668
SH 2 611
a,x 16,
OFFICE FLAU.DRl ROOM 0 GARAGE DOOR
HRO M
8 X
P-1 G"IRAG3E' DOOR
0'6 1)16 3016
S", SH
FRAMING & FOUNDATION DIM.
FINISH PER ELEVATION /
AIR INFILTRATION BARRIER
4" CONCRETE SLAB 7 16" OSB SHEATHING OR
4" GRANULAR FILL PE� SHEARWALL SCHEDULE
2X6 STUDS 0 16" O.C.
2X6 P.T. SILL W1 5/8" X 10" A.B.
PER SHEARWALL SCHEDULE OR
L& (48" O.C. TYP.) 12" MAX FROM Ld Pf
ENDS & JOINTS (7" MIN EMBED) —
z
Lc #4 HOR. REBAR @ 24" O.C.
�A FIN. GRADE I 1 0
I.it #4 VERT. REBAR
0 48" O.C.
4" DIA. DOWNSPOUT TIGHTLINE
F11 TO APPROVED DISCHARGE
00 ___T_r7 4" DIA. PERF. PIPE
PEA GRAVEL FILL
WRAP W1 FILTER FABRIC
(2) #4 CONT. @ BOT. FTG.
MIN 3" CLR. TO EARTH
�3/
5��-�30 ANG
TOP
�0�36
CA S 3068 [76C
rIXEII
rEM1
4030 EM IM FSMH 6--1
0 50] SH
[iH
F------7 -T
C!Ty OF PORT ANGELES
PIP is.-,umnce of this perMP4 i,,erd upon these plans,Sp�?-ifil-
cations and other dat? not prp%��nt the building official
tforn thereafter reqLr4:,rjQ -m of errors in -said
g the corre& MY
pn., specifications and other data, ir from prevpnting
building operations being carried on thereunder when in
-,-�—Gs of this jurisdiction.
of all codes aiJ 0_
)EVe-
050] 3850
4050]
SH SH SH PR3068 4[068
FULL
LITE S-IDER
I F SH 3850 4050
3020 F4050 850] SH
PR30168 SH SH PR3068 SH
FULL FULL
LITE LITE
1"A(/l/ F L-c/
3850 PR 3068 3850
SH FULL LITE SH
4050 41068 4050 4050
TEMP SLIDER SH SH
3050 4050
SH GREAT ROOM G-- SH 4050 41068
BEDROOM TEMP SLIDER
SHOWER 4050
30 3050 SH
ANG SH
TOP
-INE
KITCHEN
7 HR
OOM CLOSET
3030
SH
2036 2036 2036 4030
CASE CASE CASE SH
3850 PR 3068 3850
SH FULL LITE SH
4050 4050 F-7:1
SH SH 4050 4050 LL1
L'Al SH SH
-1 81-91 3020
4050 12'-0'- SH
SH FAMILY ROOM G== I PR3068
BEDROOM BEDROOM FULL
LITE
3 4j'
4030 2668 3068
SH r pr-a ; 8' X 16
OFFICE 0 GARAGE DOOR
LAUNDRY ROOM :0 IMTHRO IM
0
2
81 x 81
F- 1 GARAGE DOOR
T 4 4 ------
3016 3016 3016
SH SH SH
V-61"
2
- - - - - - - - - - - - - - - - - - - -
-1
-i
> >
CTJ
- - - - - - - - - - - --- - - - - - - - - - - - - - - - - - - -
-- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
2'-1 5'-10-71
4 4
10' 11
lGi
to
co
F- - - - - - - - - - -- - - - - - - - - - - - - - - - - - - - - --I
� -/75
2'-1 1
2'-6 8'-0 2'-0" 16'-0" 2
,31'-51"
2 8'-0
7-1 1
7 F 7 FF 7 7 F
L _JL _JL JL _J L _J L JIL __j4L__ L_
r- 7 F- 7IF___1 F 7 F F=- F- F-7-F- ---ff r-- "i f----t f
i