HomeMy WebLinkAbout1126 W 12th St - Building
"
~ ~ORT ~
$4.0~~~
,.
'- ~
~
~~
CITY OF PORT ANGELES
DEPARTMENT OF COMMUNITY DEVELOPMENT - BUILDING DIVISION
321 EAST 5TH STREET, PORT ANGELES, WA 98362
Application Number
Application pin number
Property Address
ASSESSOR PARCEL NUMBER:
Tenant nbr, name
Application type description
Subdivision Name
Property Use
Property Zoning . . .
Application valuation
05-00001114 Date 12/01/05
586412
1126 W 12TH ST
06-30-00-0-3-6930-0000-
DOUGLAS GATES
RES DETACHED GARAGE
RS7 RESDNTL SINGLE FAMILY
9097
Owner
Contractor
GATES, III DOUGLAS/CANDI
1126 W 12TH ST
PORT ANGELES WA 98363
Other struct info .
BUILDING BROKERS
P. O. BOX 3831
SEQUIM
(360) 683-6216
TOTAL % LOT COVERAGE
NUMBER OF STORIES
EXISTING LOT COVERAGE
LOT SIZE
PROPOSED LOT COVERAGE
TOTAL LOT COVERAGE
NUMBER OF UNITS
21. 90
1.00
960.00
7000.00
576.00
1536.00
1. 00
CONSTRUCTION
WA 98382
Permit . . . . .
Additional desc .
Permit pin number
Permit Fee
Issue Date
Expiration Date
BUILDING PERMIT -RESIDENTIAL
66167
207.75
12/01/05
5/30/06
Plan Check Fee
Valuation
83.10
9097
Qty Unit Charge Per
Extension
95.75
112.00
BASE FEE
8.00 14.0000 THOU BL-2001-25K (14 PER K)
Special Notes and Comments
11/29/2005 11:50 AM SROBERDS - The proposal will result
in a detached garage in the RS-7 for total lot coverage of
22%. No land use issues are noted.
The Fire Department has reviewed the project application and
has no comments
Electrical load calculations and elctrical permits are
required.
Customer advised to locate the underground service wire -
do not dig into it or build ontop of it.
11/14/2005 04:51 PM GMCLAIN ----------------------------
Asphalt , gravel or concrete driveway to City Standards.
No concrete with exposed aggregate allowed in the City
road right of way. An inspection by Public Works
Engineering is required prior to prouring concrete or
paving.
Other Fees
STATE SURCHARGE
4.50
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 207.75 207.75 .00 .00
Plan Check Total 83.10 83.10 .00 .00
~Al~
~V31 JOC:>
JVL/
...........
.........
~
\\\
t
.......
~
~
VJ
~
f;: ~
Separate Permits are required for electrical work, SEPA, Shoreline, ESA, utilities, private and public improvements. ThiS permit becomes
null and void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned
for a period of 180 days after the work as commenced, or if required inspections have not been requested within 180 days from the last
inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of
laws an ordinances governing this type of work will be complied With whether specified herein or not. The granting of a permit does not
presu . to gi ority to violate or cancel the provisions of any state or local law regulating construction or the performance of
cons uctie1l.
/2 ~ (-(2) <c-
Oate
Signature of Owner (if owner is builder)
Date
T \Pohcles\1102_15 bUlldmg pennlt mspectlon record05.wpd [1/4/20051
..lI"RT ""
t.J.O~~~
ha
"- -=->>'
~
~~
CITY OF PORT ANGELES
DEPARTMENT OF COMMUNITY DEVELOPMENT - BUILDING DMSION
321 EAST 5TH STREET, PORT ANGELES, WA 98362
Application Number . . . . .
Application pin number
Other Fee Total 4.50
Grand Total 295.35
05-00001114
586412
4.50
295.35
Page 2
Date 12/01/05
.00 .00
.00 .00
Separate Permits are required for electrical work, SEPA, Shoreline, ESA, utilities, private and public improvements. This permit becomes
null and void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned
for a period of 180 days after the work as commenced, or if required inspections have not been requested within 180 days from the last
inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of
laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not
presume to give authority to violate or cancel the proviSions of any state or local law regulating construction or the performance of
construction.
Signature of Owner (if owner is builder)
Date
Signature of Contractor or Authorized Agent
Date
T:\Pohcles\1102_15 bUlldmg penmt mspection record05.wpd [1/4/2005]
BUILDING PERMIT INSPECTION RECORD
CALL 417-4815 FOR BUILDING INSPECTIONS CALL 417-4735 FOR ELECTRICAL INSPECTIONS.
CALL 417-4807 FOR PUBLIC WORKS UTILITIES
PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE
INSPECTED AND ACCEPTED. POST PERMIT IN A CONSPICUOUS LOCATION.
KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE
INSPECTION TYPE DATE ACCEPTED COMMENTS
YES NO
FOUNDATION:
FOOTINGS 1.-n,? / or., TLV
WALLS
FOUNDATION DRAINAGE I DOWN SPOUTS
PIERS
POST HOLES (POLE BLDGS.)
PLUMBING
UNDER FLOOR I SLAB
ROUGH-IN
WATER LINE (METER TO BLDG)
GAS LINE FINAL DATE ACCEPTED BY
BACK FLOW I WATER
AIR SEAL
WALLS
CEILING I
FRAMING
JOISTS I GIRDERS
SHEAR W ALL/HOLD DOWNS I -
WALLS I ROOF I CEILING ?/'? '/O~ T./-vc?
DRYWALL (INTERIOR BRACED PANEL ONLY) / r
T-BAR
INSULATION
SLAB
WALL I FLOOR I CEILING
MECHANICAL
HEAT PUMP I FURNACE I DUCTS
GAS LINE
WOOD STOVE I PELLET I CHIMNEY FINAL DATE ACCEPTED BY:
COMMERCIAL HOOD I DUCTS
MANUFACTURED HOMES
FOOTING I SLAB
BLOCKING & HOLD DOWNS
SKIRTING
PLANNING DEPT. SEPARATE PERMIT #'s SEP A'
PARKING/LIGHTING ESA'
LANDSCAPING SHORELINE:
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCYIUSE
RESIDENTIAL DATE YES NO COMMERCIAL DATE ACCEPTED
YES NO
ELECTRICAL - LIGHT DEPT. 417-4735 ELECTRICAL
LIGHT DEPT
CONSTRUCTION R W./ PW/ CONSTRUCTION - R W
ENGINEERING 417-4807 PW / ENGINEERING
FIRE 417-4653 FIRE DEPT.
PLANNING DEPT. 417-4750 I I PLANNING DEPT
BUILDING 417-4815 'O/'?JI/ok J[7{7 BUILDING
T.\Pohcles\1102 15 bUlldm enmt ms ectlOn record05. d r 114/2005
.....
-
~
~
j "
~ N
~ ,j
~ ~
gp
p
wp[
PREPARED 3/31/06, 13 12'55
CITY OF PORT ANGELES
ADDRESS
TENANT, NBR
CONTRACTOR
OWNER
PARCEL
APPL NUMBER
INS1'ECTIOW-TTCKET
INSPECTOR: JAMES L LIERLY
PAGE--8
DATE 3/31/06
1126 W 12TH ST
DOUGLAS GATES
BUILDING BROKERS CONSTRUCTION
GATES, III DOUGLAS/CANDI
06-30-00-0-3-6930-0000-
05-00001114 RES DETACHED GARAGE
PHONE (360) 683-6216
PHONE
SUBDIV:
------------------------------------------------------------------------------------------------
PERMIT: BPR 00 BUILDING PERMIT - RESIDENTIAL
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
BL6 01
2/23/06 JLL
2/24/06 AP
BL99 01
3/29/06 JLL
3/29/06 DA
BL99 02
~
BUILDING POST/COLUMN FTG TIME: 13.00
02/22/2006 12.18 PM DYASUMUR ------------------------___
sean 683-6216
02/24/2006 08 59 AM
BUILDING FINAL TIME
03/24/2006 01 34 PM
chr1st1na 683-6216
03/28/2006 01 39 PM JLIERLY ----------------------------
03/29/2006 04:12 PM PBARTHOL ---------------------------
RECALL AFTER SLAB CAN BE WALKED ON.
BUILDING FINAL TIME: 13.00
03/30/2006 11:20 AM DYASUMUR
CHRISTINE 683-6216
PBARTHOL
13 00
DYASUMUR
-------------------------------------- COMMENTS AND NOTES ---------------------------------_____
~~{~ 1fF~iY\.e
.r
.,
PREPARED 3/29/06, 1230 28----;:.-
CITY OF PORT ANGELES
PAGE
DATE
ADDRESS
TENANT, NBR.
CONTRACTOR
OWNER
PARCEL
APPL NUMBER
,~SPECTION TICKET
INSPECTOR. JAMES L LIERLY
1126 W 12TH ST
DOUGLAS GATES
BUILDING BROKERS CONSTRUCTION
GATES, III DOUGLAS/CANDI
06-30-00-0-3-6930-0000-
05-00001114 RES DETACHED GARAGE
SUBDIV'
PHONE
PHONE
(360) 683-6216
PERMIT: BPR 00 BUILDING PERMIT - RESIDENTIAL
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
17
3/29/06
BL6 01
------------------------------------------------------------------------------------------------
BL99 01
2/23/06 JLL
2/24/06 AP
BUILDING POST/COLUMN FTG TIME
02/22/2006 12 18 PM DYASUMUR
sean 683-6216
02/24/2006 08 59 AM PBARTHOL
BUILDING FINAL TIME. 13'00
03/24/2006 01 34 PM DYASUMUR
chrlstlna 683-6216
03/28/2006 01.39 PM
13:00
3/29/06 JLL
~#
JLIERLY ------------------------____
-------------------------------------- COMMENTS
~T" ~;;;_~Jm__gz;/r/$ --- ( JU- r;,
~ t;J It-tU-
U tAl IIf1> Ut--
~
~~~~I
w~ ~ffVU7A-
~U~)
BUILDI~G DIVISION
CITY OF PORT ANGELES
* *
Correction Notice
,
'--
Job Located at t \ 7-(!.7 \.iLl
\..,
12-~
Inspection of your work revealed that the following is
not in accordance with the codes governing the work in
this jurisdiction:
C OA I P r/lL.-.rtlc--- ~~.....s~-t--
I.d <;;; P s1 tU: ( D tJ. ( LA. ) bf-7 (1 {
4. ~ v'4-J ~tz. ( A \h ~ c,. /)
C~L-
~A~ 9tJjl
C1JJ
These corrections must be made and are not to be
covered until reinspection is made4hen ~rect~ns
have been made, please call 7 - AI(
for inspection.
Date 3J79/0~
/ L
#~1
Inspector for Building Division
DO NOT REMOVE THIS TAG
PREPARED 2/23/06, 14- 19.27
CITY OF PORT ANGELES
INSPECTION TIGKET
INSPECTOR JAMES L LIERLY
PAGE
DATE
6
2/23/06
ADDRESS
TENANT, NBR
CONTRACTOR
OWNER
PARCEL
APPL NUMBER
1126 W 12TH ST
DOUGLAS GATES
BUILDING BROKERS CONSTRUCTION
GATES, III DOUGLAS/CANDI
06-30-00-0-3-6930-0000-
05-00001114 RES DETACHED GARAGE
SUBDIV
PHONE
PHONE
(360) 683-6216
PERMIT: BPR 00 BUILDING PERMIT - RESIDENTIAL
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
BL6 01 2/23/06 JLL BUILDING POST/COLUMN FTG TIME: 13:00
________~~~~___~___:::~~:~:~:::::Sl~DP:OT::A~~~-~~~~~~~~~~~~~~~~~~~~~~~~~~~_____
BUILDING PERMIT - APPLICATION
I
Fill out COMPLETELY and in INK. Your application and site plan MUST BE
C01\1PLETE to be accepted for review. If you have an)' questions, call
PERMITS (360) 417-4815 FAX(360)417-4711
Applicant or Agent~ \ L-~ \ t-.J G ~Q.o~S::. Phone: 2'c,o -(0'6 b - CoOl \ '0
Owner: G A 1" t:.. S II:> O\.J~ L~ S Phone:
Address: 11~(o W. \2~ ~\ Ci;?OE\R-kJ~t:.~
Arclutect/Engineer: E\ S \ Phone: ((DOS") 4- q % -I;;{ C( 0
ContractOI~1:^J' LD \ ~G ~~ State License #~,l()kOll ~xp: -0 t (crt ( 0(, Phone: b<63- h:;)l b
Address:~O.\bo^ 3~6' City: ScQ\JU/\/\ . WA ZIp: q~bg d
PROJECT ADDRESS: l \ Q lo L0, \ -;). ~ & . , 9, {i . I q c;s ~ COd... ZONING:
LEGAL DESCRIPTION: Lot: 4- Block: 36 q SubdivlSlon:
CLALLAM COUNTY PARCEL NUMBER: 0(0 '3 DO DO 36q ~O
ZIp:
Q8.6Co~
TYPE OF WO~
o ResidentIal ~ New Constr. 0 Re-roof
o Multi-family 0 Addition 0 Move
o Commercial 0 Remodel 0 DemolitIon
o Reparr 0 Sign
BRIEF DESCRIPTION OF THE PROJECT:
? '-\: x' d. y )( <6
~Stove
~ Garage
o Deck
o Other
SIZENALUATION:
~=1 b SF. @$/5 .-:t9 /SF. = $
SF. @ $ /SF. = $
SF. @ $ /SF. = $
TOTAL VALUATION $
----
G'A<2.RGE- (YOLE-bO~Q)iDb) I
? - '- I -
ConstructIon Type: oS \ <2 -\- l2f\/1V1 eo
S:J (0 = TOTAL Sq. Ft. I S 38
I
APPROVALS: I
PLAN:
BLDG: I
DPWU: I
FIRE: I
OTHER: I
-,
VALUATION OF CONSTRUCITON: In all case., a valnation amonnt mnst b, entered by th, appli,sm. Tlris figure will b, "vj,wL
and may be revised by the Building Division to comply with current fee schedules. Contact the Permit Coordinator at 417 -4815 for asslstande.
PLAN CHECK FEE: IF a plan check fee.is due It must be submitted at the time the building permit application and construction plans ~e
submitted. All other permit fees are due at the time of permit issuance. I
EXPIRATION OF PLAN REVIEW: If no penmt is issued within 180 days of the date ofapphcation, the application will expire. The
Building Official can extend the time for action by the applicant up to 180 days upon wntten request by the applicant (see SectIon R105.3.2
of the International BuildinglResidential Code, 2003). No apphcation can be extended more than once. I
I hereby certify that I have read and examined this applIcation and know the same to be true and correct. I am authorized to apply for this permit a d
understand that it is my responsibility to dete . what ermits are required ,not the City's, and that I must obtain such permits prior to work.
Date: -J l - g - DS:-
COMMERCIAL/RESIDENTIAL: Occupancy Group:
No. of Stories: i Lot Size: -=l 00 D Existing Sq. Ft.
Total lot coverage' Q. \, q,-\ %
.
Occupant Load:
q Coo & Proposed Sq. Ft.
PLANNING USE ONLY:
ESNWetland(s): 0 Yes 0 No SEPA Checklistrequrred? 0 Yes 0 No Other:
T. \Policies\BL-l102 _13 wpd
Applicant:
Parcel Lookup
Page 1 of 1
Parcel Number 0630000369300000
Site Address 1126 W TWELFTH ST PA
FOu,t-:1 f~Efack I
Taxpayer:
COUNTRYWIDE TSC
ATTN ALLISON COOPER
1757 TAPO CANYON RD #300
MAIL STOP SVW-24
SIMI VALLEY, CA 93063
Title Owner:
GATES, III DOUGLAS/CANOl W 1126 W 12TH ST
PORT ANGELES, WA 98363
Description:
LOT 7 BL 369
92 24X40 ARDMR S#112183
Value Summary:
Note: Listed values do not reflect adjustments made for exemption programs such as
Senior/Disabled or Current Use programs (except Commercial Forestland properties)
Land Value. 31,200
Improvements Value' 56,820
Total Assessed Value. 88,020
Property Characteristics:
Note: Use Code IS for Assessor's purposes only Contact the appropriate planning or
building departments for Zoning and allowable usage of property
Use Code' 1150 MH(REAL)
Land Size (acreage)' .00
Note Acreage IS not listed for all properties In the
Assessor's records More information about land size
Tax Status: Taxable
Tax Code Area.. 0010
Zoning Code' P _RS7
Note ZOning and zoning codes change constantly Verify all
zoning With the appropriate planning or bUilding department
Building Characteristics: (Click on Bldg # for more details)
l BldgJYIllL- Bldg. Style Total S.F. BD BA
01 Mobile Home Double/Triple Wide 952 2 1
Tax History
Sales History
~ rsacki'l
11672,54211
http://65.161.1 0.164/website/sitis--p.pgm?parcel=0630000369300000
11/10/05
Engineering & Technical Services Inc.
Duane Boice P.E.
President
STRUCTRAL CALCULATIONS
COVER SHEET .
Date: 10/27/05
Project: Building Brokers / Gates
Project Location: Port Angeles, Washington
~~~E
E.T.S. Designer: Curtis Smith
Contacts: Gary
Comments:
LOADING: ROOF LOADING= 25/5/0/5
WIND LOAD= 100 MPH EXPOSURE "C"
SEISMIC SITE DESIGN CLASS= D2
Note: THE SEAL AFFIXED TO THIS PAGE APPLIES TO THE COMPLETE SET
OF CALCULATIONS.
Initial Information
~~
/
\l\D
1 :23 PM 10/26/2005
Building Width (ft) =
Building Length (ft) =
Sidewall Height (ft) =
Roof Pitch =
Roof Height (ft) =
24
24
8
4
8.000
Wind Exposure =
Wind Speed (mph) =
Mean Roof Height (ft) =
Roof Angle =
End Zone Width (ft) =
Importance factor (lw) ==
C
100
12.000
18.435
5
1
Desi~n Loads
Horizontal Loads - Transverse Direction *
Height & Exp. Adjusted Importance Design
Location Load (pst) Adiustment Load (pst) *** Factor Load (pst)
End Zone of wall Ptw = 21.36 1.21 25.85 1 25.85
End Zone of roof ** Ptr = -6.05 1.21 -7.32 1 -7.32
Interior Zone of wall Plw= 14.17 1.21 17.15 1 17.15
Interior Zone of roof ** Ptr = -3.38 1.21 -4.09 1 -4.09
Horizontal Loads - Lonqitudinal Direction
Height & Exp. Adjusted Importance Design
Location Load (pst) Adiustment Load (pst) *** Factor Load (pst)
End Zone of wall Plw= 15.90 1.21 19.24 1 19.24
Interior Zone of wall Plw= 10.50 1.21 12.71 1 12.71
Vertical Loads - Transverse Direction *
Height & Exp. Adjusted Importance Design
Location Load (pst) Adjustment Load (pst) *** Factor Load (pst)
End Zone windward roof Pwr= -19.10 1.21 -23.11 1 -23.11
End Zone leeward roof Plr = -13.04 1.21 -15.78 1 -15.78
Interior Zone windward roof Pwr= -13.30 1.21 -16.09 1 -16.09
Interior Zone leeward roof Plr= -9.92 1.21 -12.01 1 -12.01
Vertical Loads - Lonqitudinal Direction
Height & Exp. Adjusted Importance Design
Location Load (ost) Adiustment Load (pst) *** Factor Load (pst)
End Zone windward roof Pwr= -19.10 1.21 -23.11 1 -23.11
End Zone leeward roof Plr = -10.80 1.21 -13.07 1 -13.07
Interior Zone windward roof Pwr= -13.30 1.21 -16.09 1 -16.09
Interior Zone leeward roof Plr = -8.40 1.21 -10.16 1 -10.16
* Pressures for roof angles were interpolated from Table 1609.6.2.1 (1) 2003 IBC.
** If pressure is less than zero, use zero (footnote c. Table 1609.6.2.1(1) 2003 IBC).
*** Positive values are inward acting pressure, negative values are outward acting pressure.
. "._"',":'.'~':'C./S':-L
,f" ,~I '\
ijl '::::..J~ ~ ~ -
~.si, '~:lf~~,,, ~\: 1(
.-.......:..~ ..---:..
T
~~~~:~I'J ~I~~.}:j
~\' 'd U~y
"''ri1\f.J;!->i::J; i' J
'@,!f;\'Jil( 'w
,~~~;;
Ilf n [I'
EngineCi'ing & Technical Seni{.('"~ lnc
Duane D. BoiLc I~E.
Pre~i<lcl\t
27121 4691h Ave. P.O. Box 308 Tea,SD 57064
Phone: (605) 498-1290 Fax: (60S) 498-1299
E-mail: ets I @engtecsrv.com www.engtecsrv.com
LAT'J~~ ~(..
To:__._____.___.__.____.. ____ __.__n _ _... ___
Re:
----------- ---------. -r-'-
Date:
I hereby certify lhal tt'lIS plan, specllicdtloll, or rcporl '
prepared by me or under my dlrecl persollal supelvlsloll
that I am a duly registered plofesslonal erHJlIleer under
laws or the state or._ on .. and thaI I am comPElten
prepare thiS docllment
Slgnalllle__ _ _, __ .. __ _ _ Date ! ,!.. Reg 11.- '7--'
. c::.!'(. ~ \J c. "f' r.:c.c ",oJ.
i
1
II
II
I-I j
Iii
'.1 ~ 1Co..n~..,ot.("~~
d
,I
-n~
;j
I-II -
dl
- !'-II' ..
I,
.- . Ji-
ll/
I'
'11.
"I
J-iL .- . --..
q~-
'flr~ -N:)i(\J._.
-.l~..,.-- .W ,,(~..~_'!.Psf:L~r:t~')__~ _,h_~?~...._______._..__ ....
II.
i.~t - - .<$2. ( .\~~-~~ ~f ~( '(~l? ~ ~.:~. :-.. .~~~.___ .. __ __ ____. __ _ n
pI 6>
. t;l.--- ,-.-- . C \.~.:J~ ~~'?.x. '!'l..l:/...';._. ~~ #__
Iii 8) (,J2,7IP~FX.7'lZ.')::- J78it
- j-ll - ..... - .-. . ..
I.il. c9 (\~.~~~~Y~'A. -(t_OZ:J ~ [?J q
, ,I
, ii ~ =- 110471
'T
~L.
II
ij-
I:
1'L-- .
I.il.. -
111. ..
III
:1
I il-
t;l
.(1~,iS ~f"1..~~~:?~~ -=- ~/7_#
(\1.\.>~FX.4.)(7') ~ 4So~
~ :: 9c; '1"'"
~,\,.
. -1."'-I{'~ -- ::.. '\~S-;?~F":::: r:S~--R.r--"~~--- -. --
J\0~ -
'2.4 ' - '1'
5~ P"P.
4 13:>.P'-'F ~
DESIGNED BY:
~
CHECKED BY:
, J f\~
t.
nATF' /(}-~IO-os-
Building Brokers / Gates
Date and Time: 10/26/2005 1 :29:01 PM
3!\c
MCE Ground Motion - Conterminous 48 States
Zip Code - 98363 Central Latitude = 48.009706
Central Longitude = -123.77836
Period MCE Sa
(see) (%g)
0.2 145.6 MCE Value of Ss, Site Class B
1.0 060.0 MCE Value of S1, Site Class B
Spectral Parameters for Site Class D
0.2 145.6 Sa = FaSs, Fa = 1.00
1.0 090.0 Sa = FvS1, Fv = 1.50
.'. so~ ~ J- ().e.tsu.-) -:::.. O~1\
....>01 0: ( ........
} O.",\Q~ ::. 0.<;;'
.". \)>1:: ':>E.i~~c.. ~'I1'e <-Io.~~ 0.2,
'oJ:: l.'. ~o~
- . y.J
\~
_ 1&~~O:;11
- b,S ~XlS)(t~J'I~'1t IO~Z.""W)
'oJ ~ \1 ~\ ~/ _ 011 t ~ALL ~ y.\\~ ~~eo.r
~ 'fol1\~ 0\9"
:. \.\iftD ~~ ~oJ<a(~ ~~()
1 :23 PM 10/26/2005
4/\G
Max Horizontal Wall Loads - Transverse Direction *
Height & Exp. Adjusted Importance Design
Location Load (pst) Adiustment Load (pst) *** Factor Load (pst)
1E Ptw= 14.60 1.21 17.66 1 17.66
4E Ptw= -12.17 1.21 -14.72 1 -14.72
1 Ptw = 10.59 1.21 12.82 1 12.82
4 Ptw = -9.08 1.21 -10.99 1 -10.99
Max Horizontal Wall Loads - Lonaitudinal Direction
Height & Exp. Adjusted Importance Design
Location Load (pst) Adjustment Load (pst) **if Factor Load (pst)
1E Plw= 12.00 1.21 14.52 1 14.52
4E Plw= -9.30 1.21 -11.25 1 -11.25
1 Plw = 8.80 1.21 10.65 1 10.65
4 Plw= -7.20 1.21 -8.71 1 -871
I
* Pressures for roof angles were interpolated from Table 1609.6.2.1 (1) 2003 IBe.
** If pressure is less than zero, use zero (footnote c. Table 1609.6.2.1(1) 2003 IBe).
*** Positive values are inward acting pressure, negative values are outward acting pressure.
Enginccl-ing & lcc:hnical Service!> !nc-
To-____--=--_ ____ __ ____________ __. _ _____
Re:____________________.__ _____
Du.lIlc D_ Boi<..c I~E_
Prc.\ident
Date:_______________ _____ ___ ___ _____
27121 4691h Ave. P.O. Box 308 Tea,SD 57064
Phone: (605) 498-1290 Fax: (605) 498-1299
E-mail: ets I@engtecsrv.com www.engtecsrv.com
I hereby cerlifj 11101 Ihls [ltall, spcclhcdllon. llJ mpoll
prepared by me or under my dllcct rcrsonnl superv'''lol
Ihal I am a duly registered prnfesBlofldl enyl/leer unclE
laws or Ihe state or_ _ _ . "nd Ihal I <1m compete
I
prepare Ihls documenl
Slgnature_ .nm_ ..__._ _ _ _ Dale __ j _ ._f.. Reg #_~_ ..
I
-I _ St'Q~ ",,~u.. . <:. oc..Ot'W\~
'iI .
'i!Wl...-=: ( 1:2.8~ ~S~;( \.~\)
,
I
,
j
I
i
.J.
,
t
I
-- 11 -
-- - -~t
l'lt..--
l!r
-- w- --.
- t!t.~~~..-: ',. -. . _. --.. --
III-!.o = ,. -..- ~~;;
Ir 7J:fCO~ ~ J.I ~ J?~ -: _('JII~__~ I'l:~ I~ f "_ -
h- "".- __0_ un _ .: O:.,s i.,.. 8# ~~
II!
L!-l ~t'lQc..~~_
lIt ~
'II
III
"I~'
it
f!
I,
11 ..
I'
'It.
;f ~~~:
fI, -.. ~(<J:.m
d..
I,
i!
II
"r
Ii'
"
:i
~~
-= IS4 #/+"t. -':;L
/94Jt S-
. 111.-::. 6
- ,;1$2.. ~,\..
- -- - - -
~Ol.: (.~..~ p ~r.l..t~~XJ'~6) ~_ 5~-~.----_. __.
--.--. --. . UpAD . GoIl16i,.,~ro. .___.
_ _ _ - ..Q.4-> 1)4. _"':'. ~_~__
- .._ . _J)~! c?~~~_~ .t_C){l~_;:t...
-..__ _ ._u_~t~_..._______._.
u-pl. '~T
..
__'~.Q9 ~ ~~'~/21-=-
\\590# =- .S-_'
\:(P(\~o"'~D .
\\s;B~
.'. \J,* Cro')- Zc0 ~ ln~
.tJQJC . Q~. &Jl .I~__ . b~(\ ~
~~---
DESIGNED BY: eu
CHECKFn RV-
ndTI=. IO-2t.-.-rx:-
1 :42 PM 10/26/2005
Building Brokers I Gates
8' Sidewall Columns DL +WL +SL
Bending
width (b)or (d2) =
depth (d) or (d1) =
length (11) or (lU1)=
length (12) or (Iu2)=
Moment (M) =
E=
Actual Bending Stress
fb = (6*M)/(b*(d^2)) =
3.375 inches
4.125 inches
96 inches
24 inches
1232.00 ft*lb
1500000 psi
(weak axis depth)
(strong axis depth)
(strong axis unsupported length)
(weak axis unsupported length)
(modulus of elasticity)
1544.620 psi
Theoretical Bending Capacity
F'b= Fb COCM Ct CL CFCVCfu CiCrCcCf=
Fb=
CD=
CM=
Cl=
CL=
CF=
Cv=
Cfu =
C1=
Cr=
Cc=
. Cf=
1650
1.6
1
1
0.981
1
1
1
1
1
1
1
duration
moisture
temperature
stability
size
volume
flat use
incision
repetitive member
curvature
fo J:Ill
2588.829 psi
Tables
pg 9
pg 53
pg 9
pg 15 (see below)
pg50
pg 34 (see below)
pg 53
pg27
pg27
pg 34
pg 15
from
Figure 3G
pg 18
2001 nds
pg 16 2001 nds
(f; ( \0
stress Ratio = 0.5966
2001 sup
2001 nds
2001 sup Table 4F
2001 nds
2001 nds
2001 sup Table 4E
2001 nds
2001 sup Table 4F
2001 nds
2001 nds
2001 nds
2001 nds
CL and Cv cannot be used at the same time. Use the smaller of the two, and the larger is = to 1.
CL = ((1+(Fbc'Fb*))/1.9)-(sqrt(((1+(FbEIFb*))11.9)^2)-((Fbc'Fb*)/0.95))) = 0.981
KbE=
I-
e-
0.418
189.480
Iuld = lu1/d1 =
(chose higher one) luid2 =
23.272727
7.111,1111
Cv = ~ *(((21/L)^(1/x))*(((12/d)^(1/x))*(((5.125/b)^(1/x)) = 1-278
KL= 1
L= 8
X = 10 (20 for SYP, 10 for everything else)
Fb*=
E'=
Iu to find Ie =
R 2_
B -
FbE=
2640.0
1500000.0
96
68.6
9137.5
(if greater than 1.0 use 1.0)
(for Glue Lam. Only)
1 :42 PM 10/26/2005
Deflection
Allowable (U360)= 0.2667
Allowable (U240)= 0:4000
Allowable (U180)= 0.5333
Capacity = (5wL ^4)/(384EI) =
Capacity = (PL ^3)/(48EI) =
w ratio
1.80
1.20
0.90
0.60
0.45
2.9956258
2.3965006
U360 stress ratio
U240 stress ratio
U180 stress ratio
U120 stress ratio
U90 stress ratio
U600 stress ratio
U480 stress ratio
total load
w = 154.00 plf
P= 0 Ibs
I = 19.740784 in^4
must be less than allowable
0.4793
o
P ratio
o
o
o
o
o
uniform load
point load @ midspan
(live load floor)
(total load floor, live load roof)
(total load roof)
(total load roof)
(total load roof)
live load
154.00
o
19.7407837
1(10
live load only
0.48.
o
w ratio
1.80
1.20
0.90
0.60
0.45
2.99562575
2.3965006
P ratio
O.
o
o
o
o
1 :42 PM 10/26/2005
Building Brokers I Gates
8' Sidewall Columns DL +WL +SL
Compression
width (b)or (d2) =
depth (d) or (d1) =
length (11) =
length (12) =
Area =
Force =
E=
Ke=
3.375 inches
4.125 inches
96 inches
24 inches
13.921875 inches2
5040.01b
1500000 psi
1
(weak axis depth)
(strong axis depth)
(strong axis unsupported length)
(weak axis unsupported length)
(modulus of elasticity)
Effective length (I e1) =
Effective length (I eV =
96 inches
24 inches
Actual Compression
fc = Force/Area =
362.020 psi
stress ratio = 0.348
Theoretical Compression Capacity
F'c= FCCOCMCtCFC,Cp=
1039.580403 psi
14472.90842 Ibs
from
Figure 3G
pg 18
2001 nds
F- 1700 Tables 2001 sup
c-
Co= 1.15 duration pg 9 2001 nds
CM= 1 moisture pg 53 2001 sup Table 4F
Ct= 1 temperature pg 9 2001 nds
CF= 1 size pg 25 2001 nds
C= 1 incision pg 27 2001 nds
I
CT= 1 pg 29 2001 nds
C - 0.5318 pg 19 (see below) 2001 nds
p-
Cp = ((1+(FCE/FC*))/2c)-(sqrt(((1+(FcE/Fc*))/2c)^2)-((FcE/Fc*)/c))) = 0.5318
enter values
KcE=
c=
IJd=
0.418
0.9
23.272727 chose the higher between (Ie1/d1) and (Ie2/d2)
(used to calculate F cE)
Bending and Axial Compression =
(fc/F c')L+fJ(Fb'(1-(fclF cE)))
0.99
(must be < or = to 1.0)
calculated
F/=
E'=
le1/d1 =
leid2 =
F cE1 =
F cE2=
~[\D
1955
1500000
23.27273
7.111111
1158
12399
1 :42 PM 10/26/2005
GIRT - Girts & Purlins
q{~
I
WALL GIRT DESIGN:
GIRT SPACING =
POST SPACING =
DESIGN LOAD =
. CH=
24
12
-22.6
1.5
(in)
(ft)
(pst)
LUMBER TYPE: LUMBER DIMENSION:
df#2 2x6e
Fb= 900 (psi) AREA = 8.25 in^2
Fv= 180 (psi) Sxx= 7.563 in^3
E= 1.6 (psil I e6) Ixx= 20.8 in^4
* (F - flat use & E - on edge use)
BENDING w = 45.20 (Plf)
Mmax = 9763 (in-lbs)
fb = 1291 (psi) <-actual bending stress
LOAD DURA nON - Cd =
SIZE FACTOR -Cf=
FLAT USE FACTOR - Cfu =
REPETmVE USE - Cr =
Pb = Fb(Cd*CL*Cfu*Cr) =
1.6
1.3
1.00
U5
2152.8
<--- MSR & SYF = 1.0
OTHER SAWN = 1.3
BENDING
RA TIO
0.60
(psi) <- allowable bending stress
SHEAR
v = wL / 2 =
fv = 3*V / 2* A =
Fv' = Fv*Cd*CH =
271 (Ibs)
33 (psi)
432 (psi)
<-actual shear
<-allowable shear
SHEAR
RATIO
0.08
DEFLECTION
delta allowable = L/I20=
delta maximum =
1.20 (in)
0.63 (in) (I-span)
DEFL.
RATIO
0.53
CONNECTION
IF GIRTS ARE FLAT ON POSTS USE:
I6d - Hardened Steel Ringshank Nails
4 - per Post / Girt Connection
(note: alternate girt slices at posts)
IF GIRTS ARE ON EDGE BETWEEN POSTS USE: pre-manufactured joist hangers
or blocking between girts
THEREFORE USE:
dfil2
2x6e
@
24
" O/C
I
------T~!I---
I ~ I I I i Ii! : : ! ! ! I ! '
--~- - --~__~______+-~~------ ------- -----1----- - ----__
I I I I I ! I :
I I I I 'I I I
------.. -----~ --- ----- - - --~------ ---l-------r-----...---~------ ~------- -- - --- --- -~- -
,I ': 1 \ I Ii'
--- ---"--- ---- ----- --~-- ------- ---------~----.!_--- ----~ -~---- - -- --- ---- ...-~ -- -- -- -- -- - ----- ---- ----- ---
: :',! , 'I '
_________ __ ___ _ _.. _...b._~~~_.n.MJHHHJI'L._I_.~\Al'~f:rn~vr
r88MMyr J1;r-:' B~~:fL6rMEr JT _..<:1 ASf.i6- :
I ,
-- - -- - ----- ~- ,- ----- --.----~-- -- - --;---- --- - - ~
PERMIT AP~LIC'ATlbN SITE_~LAN _ :
PLEASE SHOW ALL REQUIRED INFORMATION
i ! i ! : I I I I: I I : i i : I I ! I ! ! ! i : ill I I ! i I i I I I I. I I i
-- --- - -i----I-I--IT---:---r - ---I ----:---'----1,---- --1- -~- -1---1 - -I--~ -~ ---i-li-\-i--l-!!---!- \-II-ri-T-i--:~-n
--~----------- - --+______. _____._..u__ -.--- -------,-~----T--- .-----~------.--,---~--:---- --,
I ' , I I I I ' , I' I I I I ' , I I I , I' I
I ; I '~ ':: i I : ! I " I I ! !
----- -- - - ---'--~-'-T- " __nn --, u0~------- -- ---G-~~n' ~~' - I----~,--I----:--'--,--- ,--un;
__ _ __ -_____ --~-_ Applic~nt-' ~ It.-Pi ~~-'1~9- ---'~--..J--Staff-Initialk---;m--' __L_L__ L____~ ___~- __1___1
, ,I I I " : I, I I I I I '" I ' I I I , I i
, \ , Ii. . ! q -? ' ': ',: I" I ' , I, ,
. parcei # ,u,(~)'96ocC::X:)"3q..::)O--:------r --- I Permit # ___________l. - - I
I I I':, I I
-- __n - n___ -- --, --\-- -0------...;----- -,.---~
-; - I ! ' ,\ - t> - D~' , !U~_
'Please Indicate
, Direction
,
Applicant Sig~ature/Date
J
I
--------~, ---
/
,
,
----------
,
---- -- ---
I
- - ----- ---
---- ......-- ----
,
I
I
u_ j
I
_.1
_ _ _ _______l___ __,_ _ _ _
I
_ __.I
I
-- - -- -- .---\--
-------- ---
,
- - -- --- -~----- - -- -
,
,
--- -----------'--
!
- ----~------ -
I
!
I
__J_~_ H__ n ~ __J __ _ __ _~_ I
! I: I
__1______----- ___ _______ _1______ ____~__ ___ ____~_~____ I 1_ _~___________! ___
I 'I I 'I I I I
, I I I, I I I ! . - _ J
-- ---- ---- -. -I ---;----:-----!--TT1-i-I:--1 --!--T----;- -1--i -- 1- _n ~ ,
-- -' ---- - - -,- .----;----1 -- -,--.------------~--r-I---n.I-- -I n -;---'--1-
! I ! i I I I I! I i I I
i _;n u. - u_ - ----- ----------T--,-----.-.--;--r--,---,--l---l-i--r- T --I---i
Uu~~~-!n_:_=:T::.. , . ;'-1-!-:+ j-+T1tj- i-I- r-=:-:-=!-I::--11=I-~Ti-rT fFFf-fFl-i-: .
1---1-- -;- ----.-- ~-T--(-i---TT 1- ---I'-T-T . i - i -- J1___:___ -~~__-j_=_~_-=i._-----r~!--T~-i--l-i~l-l---r--I-l-TI-!-I--1-1--
- --------- m - -- ---- _n___ -------- m_, - --.---- -1-1-- n__ -------'--:- T--I-- +-- ~ -]---1- - - -I -r-'---'-----T-+--T-l--T-i!--l----i---r- --1---:----
"___u_ - -- -----------T.----- ---r T.--~----- ____n_ ------u.'-T------~--- i I ~--+--i-----.--- -;- -\--i-
_~~~-=~=_~-______ _ __ . __ __ __ _w-- _-_- ~_-__~_-_ _~~~ _ -~_~~_--~~=_=-_-_-_~~~=-~~~-_._=_~-~~-L___~~_~-_ _____~_~--~T ~_-; -_ ___ ______ __ -~~_~:-_-_-=-~=-==__=- I_=-~---I----I----I_=T___T~J__~ ~u_i_~I
, , + : '.-L ..l ' I I: I:' I I I " I I I I t -+ I .~i -~, ----+t----'-! --1--": - +-1 ---<-1'--- I I +--i -+1 -+- I I I '--+1- -1--1 --+, -1,---1----.,..-
I I I I------L-- - -+---1-----1. -+----+---'-----r-- 1,- ,n--rn -~-----+-----+, I I ! I, 'I I I I ---; I I :,' I I ' I
I I I I I I ~ i: ' I I!., I I,' , I, I i
-------- ---~----ml--~-I-,-i -1- - ---- -I~-----I n_____ i---..-i- -----.----,-- ~-----------:---I---I-(--i--- -i -- -~- --I ! ---'\- _:_n_, -- u:__\_ -- -[--I I, 'I Ii! ! ! I \ \ i 1-- \1 ---~\----'In---I-l, -- 1,-
___ ___~~__I_ I. __' ___1__ _~~_~_~___ ___~__~_________~_~--.l____________l__ __ _ ~_ _~__I____~__I
: , I I-~'- --:-~I---!--r ! ii, I - -1- - ~---, ---- [-- ~--~--- Ii! , ,ii I _~_ i i I Ii! I I i a - ~ ~~!~-j____~_11 i -Till ~ I 1- J CT-I-i--~i=J~_-_-[- ,
--:---r--T!~!i-.-:T:-!--I-I---~---l--'--f-!--I--,-!- 1--T--;--j-r-T-Ti---fTl--!-~~_=T-!I--:----i---r--i---i---1---:--L~'~.-J_nL_.i i 1-' I I I i IT i J_TJ__LJ_J_I __I.
~I==~--i--p,LEA~0~-T~X~_~h~~-!~~~~V!d~~for!y~~~r_~~eiEl_I~!g-~.~_~ee~~cIy-~e~~_.t~,belJSe~-d~p~h~ing ~~_t~~ ~iZerC(;~PI_~~i~y ofy~~~i~!~~Ct-1-~i.___i_ .\_~. ! I I I i I I SC~le\1"~ ~d~/! I_LL_l_J __~
i i I I I 1_.J~t I~rg,r s~ee~ IS re~I~~~ 6 ~a(iltlo~a~J~p[les eurt Die s~1)1Itt~a. I I I Ii! i I I I I J___L_l_ I I I.J---I-_Jn i I I I I I i I I LJ j I I LJ--'_I-I--i-
--1------- I I I I , I I I I I I i I i I I I I I I I I ! I I I I I : I i I I I I I I -r----II i i I I I I I I I I I I I I I I I I I I I f
-- ---- -- -
I
1
---~- -'-----~---
I
I
I
I
-. - - - m_ __u_ r~' -;-1- --j .
----- -~~-
I,
I
'~
~
CITY OF PORT ANGELES
PUBLIC WORKS - ELECTRICAL DIVISION
~21 EAST 5TH STREET. PORT ANGELES. WA 98~62
Appl~cation Number
Application pin number _
Property Address
ASSESSOR PARCEL NUMBER
Tenant nbr, name
Appl~cat~on type descr~pt~on
Subdivis~on Name
Property Use
Property Zoning .
Application valuation
05-00001114 Date
586412
1126 W 12TH ST
06-30-00-0-3-6930-0000-
DOUGLAS GATES
RES DETACHED GARAGE
3/01/06
RS7 RESDNTL SINGLE FAMILY
9097
Owner
Contractor
GATES, III DOUGLAS/CANDI
1126 W 12TH ST
PORT ANGELES WA 98363
BUILDING BROKERS
P. O. BOX 3831
SEQUIM
(360) 683-6216
TOTAL % LOT COVERAGE
NUMBER OF STORIES
EXISTING LOT COVERAGE
LOT SIZE
PROPOSED LOT COVERAGE
TOTAL LOT COVERAGE
NUMBER OF UNITS
CONSTRUCTION
WA 98382
Other struct info
21 90
1 00
960 00
7000 00
576.00
1536 00
1. 00
Permit
Addit~onal desc
Permit pin number
Permit Fee
Issue Date
Expiration Date
ELECTRICAL NEW RESIDENTIAL
OWNER/ DETACHED GARAGE
70904
48 10
3/01/06
8/28/06
Plan Check Fee
Valuation
00
o
............
~
~~
~(
r
""'-
}.J
t~
Qty
1 00
Unit Charge Per
48 1000 ECH EL-R-OUTBD/DTCH GAR SEP
Extension
48 10
Special Notes and Comments
11/29/2005 11:50 AM SROBERDS - The proposal will result
in a detached garage in the RS-7 for total lot coverage of
22% No land use issues are noted
The Fire Department has reviewed the project application and
has no comments
Electr~cal load calculations and elctrical permits are
required
Customer advised to locate the underground service wire -
do not dig into it or build ontop of it.
11/14/2005 04 51 PM GMCLAIN ----------------------------
Asphalt,gravel or concrete dr~veway to City Standards.
No concrete with exposed aggregate allowed in the City
road right of way An inspection by Public Works
Eng~neer~ng ~s requ~red prior to prouring concrete or
paving
0\
~l
,
-
Other Fees
STATE SURCHARGE
4.50
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 48 10 48 10 .00 .00
Plan Check Total .00 .00 00 00
Other Fee Total 4 50 4 50 00 00
COMMENTS/ACTION NEEDED
~
I
I
I
d'iJ.'~_
J(i~~
D8
"I.tiir~
CITY OF PORT ANGELES
PUBLIC WORKS - ELECTRICAL DIVISION
nl EAST 5TH STREET. PORT ANGELES. WA 98362
Application Number
Application pin number-
Grand Total 52 60
COMMENTS/ACTION NEEDED
Page
Date
2
3/01/06
05-00001114
586412
52 60
.00
00
ELECfRICAL PERMIT I NSPECf ION RECORD
,
CALL 4) 7-4735 FOR ELECTRICAL INSPECTIONS. PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLA WFUL TO COVER.
INSULA TE OR CONCEAL ANY WORK BEFORE IT IS INSPECTED AND ACCEPTED.
KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE
INSPECTION TYPE
DATE
COMMENTS
NO
GENERAL COMMENTS:
PW-II02.U (4'96)
I nstalled By:
CITY OF PORT ANGELES
LIGHT DEPARTMENT
ELECTRICAL PERMIT
PERMIT NO. 3.;< 90
? - :2t-P/
DATE
.
Site Address:
D READY FOR ~ILL CALL FOR
INSPECTION INSPECTION
License Number: Phone:
Owner/Business:
Phone:
Owner/Business Address:
Sq. Ft.
o Residential
Heat KW
o Baseboard 0 Furnace/Boiler
o Heatpump 0 Other
o Commercial/Industrial load
Total Connected load
(attach breakdown)
Total Motor load
(attach breakdown)
o New Construction
o Remodel
o Service update/alter/repair
o Overhead
}( Underground
Voltage
'0'1.0 03
~ervice size
o Temporary
Amps
o Add/alter circuits
o Auxiliary power
(list below)
o Special equipment
(list below)
DetailslDescription:
;no i; -;;.
~e
..5CXt//cf
I
/ hEdCX'
(
.
W.S. No. Service
Capacity: 0 O.K. 0 Not O.K.
.,p Ditch inspection O.K.
o Rough-in/cover O.K.
J,,"^^~ O.K. to connect service
/11" "F Final O.K.
Size
Comments
Date
Hold for: 0 Easement 0 Letter
o Signed up for service/meter
o Meter Department notified for installation
o Fire Department notified of inspection
o Plan Review approved/pending
Installer:
w,
Permit/Receipt No.
3.2 90
Site Address:
,
c...
New Meters
.1
.
Notify the Department of City Light by Street Address and Permit Number when ready for inspection. Work
must not be covered or electrically energized before inspection and O.K. for covering or service has been given
by the Inspector in Writing on the Wiring Report or the Building Permit. PHONE 457.0411, EXT.158 or..,EXT. 224.
. ~ NO OCCUPANCY OR USE ESTABLISHED UNDER THIS PERMIT ~D ~
Inspector Amount paid
WHITE - file by address YELLOW - file by number PINK - Top: Eng, Bottom: Customer GREEN - Top: Inspector, Bottom: City Hall
OLVMPIC PRINTERS. INC.
ELECTRICAL WORK PERMIT APPLICATION
1
Job wired by
o Electrical Contractor )21 Owner
Installation description
[J Commercial ~ Residential
Electrical contractor name
License number
Date Expires
~ew
o Altered! Addition
Purchaser's mailing address
11/".......
Iv
A/..._
City
State ZIP
Telephone number
FAX number
6if' /1..""
2-'1/
,k 2,,1
~"'r~ <!-.
h...,l./-;. .
-
Premises owner's name
\7o"9.\~~. do- c.1".\\~
~ of i~ectlOn
Ltd:tQ.--'W,". -\~
City
\>'~ ~Qe\e~
Phone number to scheaule inspection:
<=\"1-
c; C.... -\e'-..
B
OWl/er as defined by RCw'/9.28.26/:(I) Owner will OCCI/py the structure/or two
years after this electrical permit is fi"ali=ed. (2) Owner is required to hire all electrical
contractor if above said property is for sale. relit or lease.
After reading the above statement, I hereby certify that I am the owner of the above
named property or a licensed electrical contractor. I am making the electrical instal-
lation or alteration in compliance with the electrical laws, N.E.C., RCW. Chapter
19.28, WAC. Chapter 296.46B, The City of Pori Angeles Municipal Code, and
Utility Specifications.
Sig~~_~wner, cleclri I contractor or electrical administrator
X Y"r4, ""'" ~ Date: Z -/c/-G1p
Electrical Load Ad lions and or subtractions
o NO LOAD CHANGES
o Baseboard KW
o Furnace KW
o Heat Pump Ton LAR
o Fan-Wall KW
o Cash 0 Check #
o Credit Card Visa Mastercard (Qiscov0
Card# ~.!!.LL-202~IO 7~-1.z-~
,'.
Expiration Date, I
of card 10/ e;p'l
o Overhead Service
o Temp Service
o Underground Service
Voltage
PhaseD1D3
Service Size:
Feeder Size: ~ A",.
SAME DAY INSPECTION, CALL BEFORE 7:00 AM 360-417-4735
/ ROUGH-IN THERi'VIOSTAT / SERVICE
\. Dale Appro,cd By Dale ^pprol'cd By " Datc Appro'ed By
/ /' /'
FINAL DITCH / FEEDER
g-~- 06 An 2.-.;21 - 0<0 ~y ;5 - CH:> -?7<, A-r:/)
Dale Al'provcdBy/ " Dale \. Dale Approved By
Inspection Area, Building or Equipment Inspected Action Taken Electrical
Date Inspector
Ad/ 7 i,,/,./
"7 7