Loading...
HomeMy WebLinkAbout08 Prescriptive Worksheet Both ZonesPrescriptive Energy Code Compliance for All Climate Zones in Washington Project Information Contact Information This project will use the requirements of the Prescriptive Path below and incorporate the the minimum values listed. In addition, based on the size of the structure, the appropriate number of additional credits are checked as chosen by the permit applicant. Authorized Representative __Jacob Goodfellow/Timeless Contracting_____ Date __7/22/20_________________________ 1. Small Dwelling Unit: 1.5 credits 2. Medium Dwelling Unit: 3.5 credits 3. Large Dwelling Unit: 4.5 credits 4. Additions less than 500 square feet: .5 credits Option Credit(s) 1a Efficient Building Envelope 1a 0.5 1b Efficient Building Envelope 1b 1.0 1c Efficient Building Envelope 1c 2.0 1d Efficient Building Envelope 1d 0.5 2a Air Leakage Control and Efficient Ventilation 2a 0.5 0.5 2b Air Leakage Control and Efficient Ventilation 2b 1.0 2c Air Leakage Control and Efficient Ventilation 2c 1.5 3a High Efficiency HVAC 3a 1.0 3b High Efficiency HVAC 3b 1.0 3c High Efficiency HVAC 3c 1.5 3d High Efficiency HVAC 3d 1.0 1.0 4 High Efficiency HVAC Distribution System 1.0 5a Efficient Water Heating 5a 0.5 0.5 5b Efficient Water Heating 5b 1.0 5c Efficient Water Heating 5c 1.5 1.5 5d Efficient Water Heating 5d 0.5 6 Renewable Electric Energy 0.5 *1200 kwh 0.0 Total Credits 3.50 *Please refer to Table R406.2 for complete option descriptions Slabd R-Value & Depth 49j 21 int 21/21h 30g 10, 2 ft Ceilingk Wood Frame Wallg,m,n Mass Wall R-Valuei Each dwelling unit in a residential building shall comply with sufficient options from Table R406.2 so as to achieve the following minimum number of credits: *Table R402.1.1 and Table R402.1.3 Footnotes included on Page 2. Dwelling units exceeding 5000 square feet of conditioned floor area. Description Table R406.2 Summary Dwelling units less than 1500 square feet in conditioned floor area with less than 300 square feet of fenestration area. Additions to existing building that are greater than 500 square feet of heated floor area but less than 1500 square feet. All dwelling units that are not included in #1 or #3. Exception: Dwelling units serving R-2 occupancies shall require 2.5 credits. DAGNY LORD & SCOTT SCHAEFER PARCEL #: 063000-10-3130 PORT ANGELES, WA 98363 JACOB GOODFELLOW/TIMELESS CONTR. 970-531-2226 jacobtgoodfellow@gmail.com All Climate Zones 0.029 0.042 n/a 10/15/21 int + TB n/a n/a n/a 0.056 0.30 0.50 n/a 0.026 0.056 Floor Below Grade Wallc,m Glazed Fenestration SHGCb,e Fenestration U-Factorb Skylight U-Factor U-FactoraR-Valuea Table R402.1.1 Footnotes For SI: 1 foot .= 304.8 mm, ci .= continuous insulation, int .= intermediate framing. a R‐values are minimums. U‐factors and SHGC are maximums. When insulation is installed in a cavity which is  less than the label or design thickness of the insulation, the compressed R‐value of the insulation from  Appendix Table A101.4 shall not be less than the R‐value specified in the table. b The fenestration U‐factor column excludes skylights. The SHGC column applies to all glazed fenestration.  c "10/15/21.+TB" means R‐10 continuous insulation on the exterior of the wall, or R‐15 on the continuous  insulation on the interior of the wall, or R‐21 cavity insulation plus a thermal break between the slab and the  basement wall at the interior of the basement wall. "10/15/21.+TB" shall be permitted to be met with R‐13  cavity insulation on the interior of the basement wall plus R‐5 continuous insulation on the interior or exterior  of the wall. "10/13" means R‐10 continuous insulation on the interior or exterior of the home or R‐13 cavity  insulation at the interior of the basement wall. "TB" means thermal break between floor slab and basement  wall. d R‐10 continuous insulation is required under heated slab on grade floors. See R402.2.9.1. e There are no SHGC requirements in the Marine Zone. f  Reserved. g Reserved. h Reserved. i The second R‐value applies when more than half the insulation is on the interior of the mass wall. j Reserved. k For single rafter‐ or joist‐vaulted ceilings, the insulation may be reduced to R‐38. l Reserved. m Int. (intermediate framing) denotes standard framing 16 inches on center with headers insulated with a  minimum of R‐10 insulation. Table R402.1.3 Footnote a Nonfenestration U‐factors shall be obtained from measurement, calculation or an approved source or as  specified in Section R402.1.3.