HomeMy WebLinkAbout111 Whidby Avenue - Building pvA.F'-
ELECTRICAL PERMIT
CITY OF PORT ANGELES `
34I7-4735 w
Application Number . . 19-00001934 bate 12/06/19 �—
Application pin number ssosso REPORT STATE SALES TAX
Property Address . . . Ill WHIDBY AVE on your eXCISe tax form
ASSESSOR PARCEli NUMBERS 06-30-10-5-0-1548-0000
Application type description ELECTRICAL ONLY to the City of Port Angeles j
Subdivision Name . . .
Property Use . . . (Location Code 0502)
Property Zoning . . . . . . . RS7 RESDNTL SINGLE FAMILY
Application valuation . . . . 0 j
----------------w
desc
PV syetem and EV Charger
Owner Contractor
FREDERICK JOHNS/HELLE ANDERSEN POWER TRIP BNERGY'_CORP.
111 WHIM AVE 83 DENNY AVE
PORT ANGELES WA 983622556 PORT TOWNSEND WA 98368
(360) 207-7465 (360) 643-3080
Permit . . . ELECTRICAL ALTER RESIDENTIAL
Additional desc .
Permit Fee 285.00 Plan Check Fee .00
Issue Date . . 12/06/19 valuation . . 0
Expiration Date 6/03/20
Qty Unit Charge Per Extension
1.00 102.0000 ECH EL-RENEWABLE 5-KVA OR LESS 102.00
1.00 120.0000 ECH EL-0-200 SRV_FEEDER'' 120.00
1.00 63.0000 ECH EL-R.- BRANCH CIR W4/ SER FEED 63.00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
Permit Fee Total 285.00 285.00 .00 .00
Plan Check Total .00 .00 .00 .00
Grand Total 285.00 285.00 .00 .00
INSP/E N TYPE DATE: RESULTS: INSPECTOR:
DITCH
SERVICE
ROUGH-IN ;
FINAL
COWENTS:
PERMIT WILL EXPIRE SIX(6)MORTM FROM LAST INSPECTION
Signature of owner or Electrical Contractor X Date:
r _.
�. �� ��
r _
��
.. �: -
, ..
j �:� ,�"
,x
/
.
#
ELECTRICAL PERMIT APPLICATION
Pu�l'C \����8 �U� \j{�}�liC3 �)��orbn�Ri `^/'`` '
. ^ ^ ��� ���� d�/' ``
321 [ 501 S(uec{ Port /\niyc|o` \\,A 98162 �?gift,
36U�4l7.4735 / vvvvp�6tyo�` uo | dcctricu|pcnnita6�ci(ynh�ous ~
IAS
111 \8/hid '
Project Address:
Project Description: Residential roof-top, grid tied 9.45.kW solar PV installation and EV Charging Unit
8ing|a'Fami|yReoidontia| [] Dup|mx/ARU Building Square footage: 1268
OWNER INFORNINFION
Name: Rick Johns Email: ardeaco@yahoo.com
Mailing Address: 111 Whidby Ave. Port A | VVA08362 phone: 380-207-74G5
Name: Power Trip Energy-Shawn Dinkuhn License: POWERTE964JN
Mailing Address: 83 Denny Ave. Port Townsend WA 98368 Expiration Date: 4/2020
Email: shawn@powert�ipenergy.com Phone: 360-64-3080
itam Unit Charae Quantily Iqlat(Quantity x Unit Charge)
Branch Circuit W1 Service Feeder $5.00 $
Branch Circuit W/O Service Feeder $63.00 $ 63.00
Each Additional Branch Circuit $5.00 $
Branch Circuits 1-4 *75.00^ $___—_--_+_- �
Temp. Service/Feeder 2UOAmp. $93.00 $_--___----'
Temp. Service/Feeder 2O1-^OU Amp. $110.00 $___------_
Temp. Gomime/Feador4O1~OOOAmp. $149 ��' __�__�� �- ��� $______—_�_
Temp. Service/Feeder AO11OU0Amp.
Portal 0u Portal Hourly ��. �|' � �� � �. � ��� $96-00 ��
Signal Circuit/Limited Energy'1&2DV. $84.00� `� � ____ �� '��
Manufactured H Connection �� � $12000 $Renewable Elec. Energy: 5KVA System or less $102.00 $ 102.00
Thermostat(Note: $5 for each additional) $56.00 $
IMP
Ownerasclefined by RCW.19.28.261: (1)Ownerwill occupy the structure for two years after this electrical permit is finalized.(2)Owneris
required to hire an electrical contractor if above said property is for sale, rent or lease. Permit expires after six months of last inspection.
After reading the above statement, I hereby certify that I am the owner of the above named property or a licensed electrical contractor. I
am making the electrical installation or alteration in compliance with the electrical laws, N.E.C., RCW Chapter 19.28,WAC. Chapter 296-
46B,TheCdyofPort Angeles Municipal Code, and Utility Specifications and PAMC 14.05.050 regarding Electrical Permit Applications.
Date:2019.12.04 1
12/3/2O1�� Shawn 0nkuhn Shawn ��'OkU��K) o��n«»�»em�a»�momx »n
Date Print Name Gk]natuna(E] OwnerC0 Bac��a| Contractor/Adminis�ob�)
��
[Electrical Permit Applications may be submitted to City Hall or electricalpermits@cityofpa.us or faxed to 360.417.4711]
AC PC SYSTEM STATS
PV MODULE Make and model—X21-350-C-AC
INVERTER Make and model—SunPower 320W
Max AC amps— 1.31 A (continuous)
AC volts—240V
AC watts—320W
SYSTEM
# of branch circuits—3
# of inverters in branch circuit— 10, 10, 7
Branch circuit operating amps— 13.1 A, 13.1 A, 9.17A
System operating amps—35.91 A (continuous)
System operating volts—240V
Sizing Conductors and Overcurrent Devices (690.8(B)(1)
Circuit Breaker- (operating amps x 1.25 = 19.65A (20A breaker)
Branch Circuit-#12 THHN minimum
System breaker—continuous output of all inverters x 1.25 —44.21 A
System (from combiner to service panel—#8THHN minimum
45/50A Circuit Breaker
Equipment Grounding Conductor-#12 minimum
This PV system includes AC PV modules. The inverter is built into the module at the
factory and fall under NEC 690,6
rnnnRnrinp
� e9ui}mxnt
- -a THrtr
-LluftiMeer 353. {
77
} i
I
PrCdtxtian--
Cc nh,rrc;Ps.—
t
i iS 1i'5fiA .
10 6_.0 ,
JA ! [
._._.:.:.:..:. ......: ..___ 31A IN13,IA;continuous
1.31A r.W 13.1A;conbnaars
The SPR AOSO n.dule is 1.31A continuous and 12 can be m oref bramh-it fora total or HzF;°i9-'T'.;ATcV�&°'Iu'eaicc+
Tumor,c f the utility paver enfl turn off the in„ertets and cmply wRh raaid shutdeswe require. nts
`3517;MIN lqsw6 T �r a
ELEr PERMIT � I
Y_ ►kr A GELES
y 3
_ j S N ' 1�
on'NOr' 19-00000751 Date 5/22J19 - "�"�
w ,r Afro -p6tio x P fiber 540624 REPOj TSTAV SALES W
PrcYC 'Idaress 1620 D ST Can UI'l,Kt;/Se-tax fOt/n PARCEL NUMBER: 06-30-00-0-44-40as-0000- }�
s*ticu type description ELECTRICAL MY to the City of Port AngelEs'
v�^, p Name . . .
_ (Location Code 9502)
Pr `Zoning RS7 RESDNTL SIMLB FAMILY
P,ppl tion valuation. 0
Aplyli
Hot tubk
-- ------- ------ - ---- --- - ---- - --- - ------ .
Cwner Contractor
-- -- ------------------ __ - - ----------
' .. SUNNY HOLTHE Abt6 LB$ CTRIC
x' 2Q ., 524 E. SST ST.
RT wA � t56 PORT AwakEs wA. 98362
(3601 4S2-9264
ELECTRICAL. RESI;iIAL.
' @ 1-4 CIRCUITS.
8`ee 75.00 P1x.Chack Fee
'011ue Date 5/22/19 Val�attion 0
rtpination 1la 11/18/19
f Unit Charge Per Extension . Y
_ BASE FEE - - 75.00
----------- -
3
Fee s - xi Pam# edited I '
Permit otal y ?5 00 00 R (!0
"Sp al 00 00 .00 Ofl
r Gr Tt�i 75.00 75.00 .00 :00 E
avaov
PA
,
#NSPECTION TYPE DATE; INSPECTOR
DITCH
ROVOIR4N
_ FI A - _
CQ +IlI+IENTS:
Ilk
IRE SIX(6)MONTHS FROM LAST MSPI3 OON
z
signatuivdovv Electrical ContactorX Date:
r
t.
4
i
l
{
I
� t
ua/G'1/ZU19 07:55 FAX 360 452 9265 Angeles Electric
4 0001/0001
SINGLE-FAMILY � ���� V
,
LECTRICAL PERMITAPPLI ATIQN N-�
Public NVarks and,Utilities Department
" ... i
321 E. 5th Street,Part Angeles, WA 98362 I
360.4 t 7.4735 I ww%v-Cityofga.us I electricalpermits(a3cityofpa us
Project Address:
Project Description:
CV-s'ingie-Family Residential C7 Duplex/AFRU Building Square footage:
OWNER INFORMATION
Name: %'�°' Email:
Mailing Address:
CONTRACTORELECTRICAL
Name: License:&14rCL-Y�-.24&Q
Mailing Address: Expiration Date: 6Z-0 1-20 2 Q
Email: .....Y-11- 1p1tr __l .t91ZliY? tdS.d?P Phone: 300- 45242. i►4
PROJECTDETAILS
l2ttB2 Unit Charge 'lttltntlllY If1W(tivant[ty x Unit Charge)
Service/Feeder 200 Amp. $120.00 $
Service/Feeder 201-400 Amp, $146.00
Service/Feeder 401-600 Amp. $205.00 $_
Service/Feeder 601-1000 Amp. $262A0 $
Service/Feeder over 1000 Amp. $373.00 $.w .":
Branch Circuit W/Service Feeder $5:00 $
Branch Circuit W/O Service Feeder $63.00 $
Each Additional Branch Circuit $5.00 $
Branch Circuits 1-4 $75.{}4 . _ $
Temp.Service/Feeder200.Amp. $93:00 $
Temp.Service/Feeder 201-400 Amp. $110.00 $
Temp.Service/FeaiBpf7^ * �- .
Temp.Service/Feed Ott Amp.
Portal to Portal Hourly "
Signal GircuitfUrnited En` -
Manufactured Home Conn '
Renewable Elec,Energy:5KV
Thermostat(Note:$5 for each ad
•
TOTAL S
Owner as defined by RGW.19.28.261:(1)Owner will occupy the stnxture for two years after this electrical permit Is finalized.(2)Owner is
required to hire an electrical contractor If above said property Is for sale.rent or lease.Pemmlt expires after six months of last Inspection.
After reading the above statement.I hereby certify that I am the owner of the above named property or a licensed electrical contractor.I
am making the electrical installation or alteration in compliance with the electrical laws,N.E.C.,RCW.Chapter 19.28,WAC.Chapter 29&
468,The Cyy of Port Angeles Municipal Code,and Utility Specifications and PAMC 14. .050 reyrd in�Electrlcal Permit Applications.
f
Date Print Name Signature(❑ Owner Volffedfrical Contractor 1 Administrator)
[Electrical Permit Applications may be submitted to City Nall or electricalpermits@cityofpa.us or faxed to 360.417.47111