HomeMy WebLinkAbout111 Whidby AveRS7 RESDNTL SINGLE FAMILY
0
REPORT STATE SALES IAX
on your excise tax form
to the City of Poft Angeles
(Location Code 0502)
-o
-.Aw
Application Nunrlcer
Application pin nunber
Property Address
ASSESSOR PARCEL IWMBER:
Applicatsion type description
subdiwision Name
Property Use
Property zoning
Applicacion valuaEion
19 -oooo1934 Date L2/ 06/19
850550
111 W}IIDBY AVE
05 -3 0 - 10- 5 - 0 - 154 8-0000-
ELECTRICAI, ONI,Y
Application desc
PV syetem and EV Charger
ContracEor
FREDERICK .]OHNS/HEILE ANDERSEN
111 WHIDBY AVB
PORT ANGELES '{A 983 522555
136A) 2A7 7465
POI{ER TRIP ENERGY CORP.
83 DENNY A\'E
PORT TOWNSEND WA 983 58
(360) 543-3080
Per:mit
Additional desc
PermiE Fee
lssue Datse
Expiration Date
285.00
t2/a6/19
6/a3/2a
ELECTRICA! ALTER RESIDENTIAL
0
0ry
1.00
1.00
1.00
Unit Charge Per
102.0000 ECH
120.0000 EcH
63 .000 0 ECH
EL-RENEWABLE 5-KVA OR ],ESS
EL-O-2OO SRV FEEDER
EL'R' BRANCH CIR WO/ SER FEED
Extsension
102.00
120.00
63 .00
charged Paid Credited Due
Permit Fee Total
Plan Check Total
Grand Total
285
245
245
245
00
00
00
00
00
00
o0
o0
00
00
00
00
PERMIT WILL EXPIRE SIX (6) MONTHS FROM LAST INSPECIION
INSPECTION TYPE RESULTS:INSPECTOR:
DITCH
SERVICE
ROUGH-IN tz/tz/tt w \GF
t/)zln P \"4
COMMENTS:
Signature ofowner or Electrical Contractor X Date
ELECTRICAL PERMIT
CITY OF PORT ANGELES
360-4r7-4735
Plan Check Fee
Valuatioll
.00
DATE:
FINAL
ELECTRICAL PERIVI IT APPLICATION
Fubli* tr{rorks and Lftilities Deprrl'lm*r:t
3: I D. -(th Strcrt, Pol't i\nqeles. \V,{ 9iJ.1tr2
l(r(),,-l I7..+7.15 I rvwu.citr, olp:r.us ; e lectric r lpcll:r iisir.r. c it;'rfur ^ u s
P€c..,
0q ;;;tc
Proje ctAddress: 1 l1 Whidby Ave. Port Angeles, WA 98362
Project Descript 1on Residential roof-top, grid tied 9.45 kW solar PV installation and EV Charging Unit
Name Rick Johns
Mailing Address 1 11 Whidby Ave. Port An geles WA 98362
Ema il ardeaco@yahoo.com
p6eps. 360-207-7465
Name Power Trip Energy - Shawn Dinkuhn li6snss POWERTE964JN
Mailing Address 83 Denny Ave. Port Townsend WA 98368
Email. shawn@powertripenergy.com
Expi ,^1,6n 9216 412020
phone 360-64-3080
Item
Service/Feeder 200 Amp.
Service/Feeder 201-4OO Amp.
Service/Feeder 401-600 Amp.
Service/Feeder 601-1 000 Amp.
Service/Feeder over 1000 Amp.
Branch Circuit W Service Feeder
Branch Circuit W/O Service Feeder
Each Additional Branch Circuit
Branch Circuits 1-4
Temp. Service/Feeder 200 Amp.
Temp. Service/Feeder 20'1-400 Amp.
Temp. Service/Feeder 40'l-600 Amp
Temp. Service/Feeder 601 -1 000 Amp.
Portalro Portal Hourly
Signal CjrcuiVLimited Energy -'1&2 DU.
Manufactured Home Connectlon
Renewable Elec. Energy sKVA System or less
Themostat (Note $5 for each additional)
Iqih! (Quantity x Unit charge)
s 120.00$120.00
$146 00
$205 00
$262.00
$373.00
$5.00
$63.00
$5.00
$75.00
$93.00
$110 00
$149.00
$168.00
$96.00
$64.00
$120.00
$102.00
$56.00
TOTAL
Owner as def ined by RCW 1 9.28.261 : (1) Owner will occupy the structure for two years after this electrical perm it is finalized. (2) Owner is
required to hire an electrical contractor if above said property is for sale, rent or lease. Permit expires after six months of last inspection.
After readlng the above statement, I hereby certify that I am the owner of the above named property or a licensed electrical contractor. I
am making the electrical installation or alteration in compliance with the electrical laws, N. E.C., RCW Chapter '19.28, WAC. Chapter 296-
468. The City of PortAngeles Municipal Code, and Utility Specifications and PAIIC 14.05.050 regarding Electrical Permit Apptications.
121312019 ShawnDinkuhn Shawn Dinkuhn Digitally signed by Shawn Dinkuhn
Date: 2019 12.04 1510212 08'00'Date Print Name Signature (E Owner p Electrical Contractor /Administrato0
[Eleckical Permit Applications may be submitted to City Hall or electricalpermits@cityofpa. us or faxed to 360.4jZ .47'l1l
1 - 2 SINGLE-FAIVIILY 1lo
=
s
t_L5lr
LO
{ i.lIt-'r
tr Single-Family Residential ! Duplex / ARU Building Square footage: 1 268
GuantiE
1
1
1
$_
E 102.00
$_
q
q
$ 63.00
$_
q
q
c
AC PC SYSTEM STATS
PV MODULE. Make and model - X2l-350-C-AC
INVERTER Make and model - SunPower 320W
Max AC amps - l.3lA (continuous)
AC volts - 240V
AC watts -320W
SYSTEM
# of branch circuits - 3
# of inverters in branch circuit - 10, 10, 7
Branch circuit operating amps - 13.1A, 13.1A,9.17A
System operating amps - 35.91A (continuous)
System operating volts - 240V
Sizing Conductors and Overcurrent Devices (690.8(BXl)
Circuit Breaker - (operating amps x 1.25 - 19.65A (20A breaker)
Branch Circuit - #12 THFIN minimum
System breaker - continuous output of all inverters x1.25-44.21A
Systeni (fronr combiner to service panel - #8THHN nrinimum
45/50A Circuit Breaker
Equipment Grounding Conductor - #12 minimum
This PV system includes AC PV modules. The inverter is built into the module at the
factory and fall under NEC 690.6
rlrsprr:.r&r!Ei(i14.,:nr'.a!a.ri:..r,r!*rr*irliir!.,..irt;r€!,1i;ill,r.$\r.1i.iF,l &r!.*.r ,n ij in l|. *rrrj F.,*r r* r! rtrl, i.i{.*r. ..q!i5i.n!.
I
i
l
I
ll
i
I
I
I