HomeMy WebLinkAbout122 E Front St 200 (2)ELECTRICAL PERMIT
CITY OF PORT ANGELES
360-417-4735
\,
\cN
N
,
Applicatsion Numbe. .
Appfication Pin number
Pr:operty Address
ASSESSOR PARCEI, NUMBER I
Appl icatsion t).pe description
Subdivision Name -
Proper:tsy Use
Properly zoning
Application valuation
2L-ooaot422 DaLe tL/ 04 /21
140s90
122 E FRONT ST AOO
06 -30 -00-5-1- 1510- 0000 -
E],ECTRICAIJ O][l,Y
CENTRAL BUSINESS DISTRICT
0
ADAIVI & THAO KNOTT
403 S. L]NCOI,N ST PMB 62
PORT ANGEIES WA 98362(360) 9 -O474
POWER TRIP ENERGY CORP .
83 DENNY AVE
PORT TOIdNSEND WA 98368
(360 ) 543-3080
Permit
Additional desc
Permit Eee
Issue Date
Expiration Date
120.00
at/04/21
s/03/22
.00
0
ory units charge Per
1.00 120.0000 EcLl EL-0-200 sRV FEEDER
ExEension
120.00
Charged Credited Due
Permits Fee Tolal
Plan check ToEal
Grand Total
120
120
00
00
00
00
00
00
00
00
00
L20
t20
00
00
00
REPORT SALES TN(
on your excise tax form
to the City of Port Angeles
(Location Code 0502)
INSPECTION T\?E DATE RESULTS INSPECTOR:
DiTCH
SERVICE
ROUGH-IN t lw/zz I \U^>
FINAI
"+lm)zz-+P :s9
COMMENTS
PERMIT WILL EXPIRE SIX (6) MONTHS FROM LAST INSPECTION
ApplicaEion desc
PVC sysEem
Plan Check Fee
Valuation
ELECTR]CAI, AITER RESIDENTIAL
Signature of owner or Electrical Contractor X Dato:
C: EXCHANCE BUILDINC --
-3AOyr3U ION OO -
s^vo 9l Nll{lti o:Ll3'ldtroc 3w
sNotrc3uHoc NaHffr 8olc3dsNl AJlloN
__lta4Pr-aa@
olo3lN sNorI93u809
" " " 3ClAH:lS
u:l^oc/Nt Hsnou "-1rf1$4,{ &"a(]
HCUO'''
o3AOUddV 10N
92lt-LL?
ruodSu cNtuun
NOrrc3dsNrtvclurc3l3
tr
tr
tr
tr
o3AOUddV
sslaoovh2-aar** A(_aL,JZ*f,*,,
^i{r
-ZZl',1'(7
:rvo
s2EKc-
W,
'' ' IVN|J tr
'tr
tr
@Z \5 \t<o4 -^ zLl
1 - 2 SINGLE-FAMILY
ELECTRICAL PERIU IT APPLICATION
Pubrtic Works and LTtilities Department
321 E. 5th Street, Port Angeles, \L',{ 98362
360.4t 7.4735 | wrvw'"citorofpa.us I electricalpelnits@citycfpa.us
1lo
=I
D
-EN
J'l
Project Address 122 E Front St Port Anoeles , wA 98362
Project Description 7.0 kW Grid-Tied Roof-Mounted PV
d Singte-famity Residential E Duplex / ARU Building Square footage
Name: Adam Knott
Mailing Address: 90 Farnsworth Place Sequim, WA 98382
Email: kcroston@centurylink.net
phone: (360) 460-3233
112mg. Power Trip Energy License:POWERTE964JN
Expiration Date 4-15-2022
p6sng (360) 643-3080
it Charge)
Mailing Address
gr";1. buddy@
83 ve Port Townsend, WA 98368
.com.
Item
Service/Feeder 200 Amp.
Service/Feeder 201*400 Amp.
Service/Feeder 401600 Amp.
Service/Feeder 601 -1 000 Amp.
Service/Feeder over 1000 Amp.
Branch Circuit W/ Service Feeder
Branch Circuit WO Service Feeder
Each Additional Branch Circuit
Branch Circuits 1-4
Temp. Service/Feeder 200 Amp.
Temp. Service/Feeder 201-4OO Amp.
Temp. Service/Feeder401-600 Amp.
Temp. Service/Feedei 601-l000 Amp.
Portal to Portal Hourly . ..,:l-...
Signal CircuivLimited Energy,,1g2 9g
Manufactured Home Connection-..
unit Charqe
$120.00
$146.00
$205.00
$262.00
$373.00
$5.00
$63.00
$5.00
$75.00
$93.00
$110.00
9149.00
$168.00
$96.00
$64.00
$120.00
Renewable Elec. Energy $102.OO
Thermostat (Note: $5 for $56.00
TOTAL 120.00
Owner as defined by RCW 19.28.261: ('l) Owner will occupy the structure for two years after this electrical permit is finalized. (2) Owner is
required to hire an electrical contractor if above said property is for sale, rent or lease. Permit expires after six months of last inspection.
After reading the above statement, I hereby certify that I am the owner of the above named property or a licensed electrical contractor. I
am making the electrical installation or alteration in compliance with the electrical laws, N.E.C., RCW. Chapter 19.28, WAC. Chapter 296-
468, The City of PortAngeles Municipal Code, and Utility Specifications and PAMC 14.05.050 regarding Electrical Permjt Applications.
10t29t2021 An Cochrane
Date Print Name ignature (E Owner Electrical Contractor / Administrator)
[Electrical Permit Applications may be submitted to City Hall or electricalpermits@cityofpa. us or faxed to 360.417.471'l]
, ,-,- -L { I ll r'. rr "l
EL€er Rl cAL: qpNTRACTO R r N F.OEWSmO N
Ouantitv
I
q
120.00
$_
$_(
q
s_
c
$_
q
$_
$
q
, Solar Agent: MichaelSlater Client Name: Knott Property
Power Trip Energy Corp
83 Denny Ave, Port Townsend, WA 98358
(360)643-3080
www.powertripenergy.com
LIC: POWERTE964JN
Project: Knott Commercial Property- Client: Ken Croston
Phone: (360) 460-3233 Address: 122 E Front 5t., Port Angeles, WA 98352
System Description: 7.0 Commercial Grid-tied PV
Solar Modules:
Branch Circuit B-10 SunPower 350W AC modules
Model: SPR-X2l-350-AC-BLK
Micro inverter max power output 320 watts
Roof
Solar Modules:
Branch Circuit A-10 SunPower 350W AC modules
Model: SPR-X2l-350-AC-BLK
Micro inverter max power output 320 watts
Roof
AC System Disconnect:
(For Rapid Shutdown of AC Modules)
Exterior south wall of building
Utility Grid: City of Port Angeles
Net Meter:
Exterior south wall of building
Meter #: 60288
Customel Owned
Production Meter:
lnterior south wall
of mechanical room
Main Service Panel (IOAD):
lnterior west wall of mechanical
room
3October 5, 2021
Ac Circuit Combiner Panel:
lnterior south wall of mechanical
room
Solbr Agent: Michael Slater Client Name: Knott Property
Flat roof- Lo€ation of 20 SunPower 350W AC modules. Conduit run to AC disconnect in yellow.
Dimensions for module layout
C=604
b=3
October 5, 2021
.=37.:39 B=3OE
Power Tr,p Energy Corp
83 Denny Ave
Port Townsend, WA 98368
(360)643-3080
www.powertripenergy.com
LIC: POWERTE964JN
Project: Knott Commercial Property, Client: Ken Croston
Phone: (360) 460-3233, Address: 122 E Front 5t., Port Angeles, WA 98352
System Description: 7 Commercial Grid-tied PV
Project Photos and Notes:
r:a
5' spacing between rows
30' of roof to work with
-4-
. Solar ABent: Michael Slater Client Name: Knott Property
lnterior west wall of mechanical room- Locatlon of breaker panel
lnterior south wall of mechanical room- Location of combiner panel, production meter and data monitoring
Roof top of residence- Location of 20 SunPower 350W AC modules
Exterior south wall of residence- Location of AC disconnect and utility meter
October 5, 2021
r
j'" l
AC PC SYSTEM STATS
PV MODULE Make and model -X22-350-C-AC
INVERTER Make and model SunPower 320W
Max AC amps - 1.31A (continuous)
AC volts - 240V
AC watts -320W
SYSTEM
# of branch circuits -2
# of inverters in branch circuit - 10, 10
Branch circuit operating amps - 13.1A, 13.IA
System operatin g an,ps - 26.2A (continuous)
System operating volts - 240V
Sizing Conductors and Overcurrent Devices (690.8(BX1)
Circuit Breaker - (operating amps x 1.25 : 19.65A (20A breaker)
Branch Circuit - #12 THHN minimum
System breaker - continuous output of all inverters x | .25 - 32 .7 5 A
System (from combiner to service panel #STHHN minimum
40A Circuit Breaker
Equipment Grounding Conductor - #12 minimum
This PV system includes AC PV modules. The inverter is built into the module at the
factory and fall under NEC 690.6