Loading...
HomeMy WebLinkAbout606 E 4th St - Building .s ~r,~ CITY OF PORT ANGELES PUBLIC WORKS - ELECTRICAL DIVISION 321 EAST 5TH STREET. PORT ANGELES. W A 98362 ELECTRICAL PERMIT Issued: 5/01/97 Permit No: 5911 OWNER/APPLICANT------------------------PROPERTY LOCATION------------------------ SUSAN HOWE 606 E. 4TH STREET Port Angeles, WA 98362 360/452-2924 T: S: 606 Lot: Block: Sub: Parc No: 4TH ST E 8 17,3 Long Legal: TPA CONTRACTOR-----------------------------DESIGNER--------------------------------- BOB'S ELECTRIC 1227 DEER PARK RD. PORT ANGELES, WA 98362 360/457-6887 , 000/000-0000 PROJECT INFO-------------------------------------------------------------------- prj Type: RES.REMODEL prj Value: $0.00 Occ Type: Cnstr Type: ADD CIRCUITS Occ Grp: Occ Load: Land Use: RS7 Electrical Heat Baseboard KW: Furnace KW: Heat Pump KW: Fan/Wall KW: o o o o Service Type Riser X Overhead Service Underground Service Temp Service Voltage: Diameter: Service Size: Feeder Size: 120,240 X-I -3 200 AMPS o AMPS PROJECT NOTES--------------------------------------------------------------_____ wire new utility room PROJECT FEES ASSESSMENT--------------------------------------------_____________ Service: $0.00 Additional Feeders: $0.00 Circuit Wiring: $40.00 Temp Service: $0.00 $0.00 Misc TOTAL FEE: Amount Paid: $40.00 $40.00 ================================= TOTAL FEE: $40.00 Balance Due: $0.00 COMMENTS/ACTION NEEDED ELECTRICAL PERMIT INSPECTION RECORD CALL 417-4735, FOil. ELECTRICAL INSPECTIONS. PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLA WFUL TO COVER, INSULA TE OR CONCEAL ANI' WORK BEFORE IT IS INSPECTED AND ACCEPTED. KEEP PERMIT CARD AND APPROVED pLANS AT JOB SITE [NSPECll0N TYPE DATE COMMENTS :"(0 , f GENERAL COMMENTS, PW-II02."14l96j . CITY OF PORT ANGELES LIGHT DEPARTMENT 321 E. Fifth Street Port Angeles, WA 98362 (206) 457-0411 Site Address: toe z. ~# o READY FOR o WILL CALL FOR INSPECTION INSPECTION Installed By: 30ls 8~ I License Number: Phone: Owner/Business: .--,-.. W/(! /rvt1S= Phone: -1-II.M- Owner/Business Address: Sq. Ft. ELECTRICAL PERMIT PERMIT NO. .s-</77 ..3 /? /y~ DATE ELECTRIC HEAT o BASEBOARD KW _ o FURNACE KW _ o HEAT PUMP KW_ o FAN/WALL KW _ o RESIDENTIAL o COMMERCIAL o NEW CONSTRUCTION o REMODEL ~ADD/ALTER CIRCUITS o SERVICE UPGRADE/REPAIR o TEMPORARY SERVICE o RISER )l'Q OVERHEAD SERVICE o UNDERGROU~D S'3RV}CE VOLTAGE: IZDg.vl9/ Jk'1 rjJ 0 3 rjJ , SERVICE SIZE 2c90 AMPS FEEDER SIZE AMPS DetailslDescription: TI/./sh.-// G-FC-I -10 CJlJ-/d c.J~ MCc;L dea4L Ga1r. J.o :?~C P . tV~ 2 Y//?-GP tU(~L W.S. No. SERVICE SIZE CAPACITY: o O.K. 0 NOT O.K. ACTION REQUIRED: 0 CHANGE TRANSFORMER o INSTALL SERVICE POLE DATE ENGR. o OVERHEAD SERVICE APPROVED o CHANGE SERVICE WIRE o OTHER o Ditch Inspection O.K. o Rough-in/cover O.K. o O.K. to connect service o Final OX Site Address: Permit/Receipt No. S1f7 Installer: New Meters --- . Notify Port Angeles City Light by Street Address and Permit Numberwhen ready for inspection. Work must not be covered before inspection and O.K. for covering has been given by the electrical inspector in writing on either the Wiring Report or on the Building Permit. PHONE 457-0411, EXT. 224. NO OCCUPANCY OR USE ESTABLISHED UNDER THIS PERMIT $ -/~ I . Electrical Inspector &0 I~- Permit Fee WHITE - File by address PINK - Top: Eng, Boltom, Customer GREEN - Top: Meter Dept., Bottom: City Hall OLYMPIC PAINTERS INC. ELECTRICAL PERMIT CITY OF PORT ANGELES 360 -417 -4735 Application Number . . . . 1G- 00000308 Date 3/03/16 Application pin number . . . 664340 Property Address . . . . . . 606 E 4TH ST ASSESSOR PARCEL NUMBER: O6 30 -00 -0 �- 7335 -0000- REPORT STATE SALES TAX Application type description ELECTRICAL ONLY on your excise tax form Subdivision Name. . . . . . . Property Use to the City of Port Angeles Property Zoning . . . . RS7 RESDNTL SINGLE FAMILY (Location Code 0502) Application valuation . . 0 Application desc Security system ---------------------------------------------- --------------- ----- --- - - - - - -- Owner Contractor RESULTS: -- ---- --- --------- - - - HOWE SUSAN L - -- ------------------------ PROTECT YOUR HOME 606 E 4TH ST 3760 PRIORITY WAY SOUTH pRIVE PORT ANGELES WA 98362 9200 ROUGH-IN INDINAPOLIS IN 46244 FINAL (317) 810 -4720 Permit . . . . . . ELECTRICAL ALTER RESTDENTTAL Additional desc . . Permit Zee . . . . 64.00 Plan Check Fee 9'0 Issue Date 3/03/16 Valuation . . . . Q Expiration Date 8/30/16 Qty Unit Charge Per Extension 1,00 64.0000 ECH EL- SINGLE CIR LIMSTED PES 64,00 Fee summary Charged Paid Credited Due Permit Fee Total. 64.00 64.00 .00 .0❑ Plan Check Total .00 00 .00 .00 Grand Total 64.00 64.00 .00 .04 INSPECTION TYPE DATE: RESULTS: INSPECTOR: DITCH SERVICE ROUGH-IN FINAL COMMENTS: PERMIT WILL. EXPIRE SIX (6) MONTHS FROM LAST INSPECTION Signature of owner or Electrical Contractor X Date: Lsr V714 ALI RECEIVE ln�, lJ CITY OF PORT ANGELES PERMIT APPLICATION — Building Diviision/Electrical Impections MAR q "101 ! r•f�� 321 Fst Fifth Strut —P.O. Box 11.501 Dort Angeles Washington, 98362 �V Ph: (360) 417.4735 Pax: (360) 4174711 Late: 03/01/2016 E$�Em 4 �1 � �;�ragle�ly C%ilillg "dataFe ewMtySe _ Vjmm #hStGmode Eledrf iRanPeAswI wi naffm i JobAdkem t}gjlcf�iffAg. Inslallallon of a low voltagehomesecurit,r system ........... _ �_,.��..�.., 0n7W ktfofralation Nam, Susan Howe �ortAngeles �tt3..�#�...�.,., ilt�IE�. 20DAV ; 0MWFeedEr2Df-4WMjX SvicyF eJWW1- 1ADDFns. 8etviOwFeedierow 1c6Ns Warsd7OXIAW Bra xh oAt &Mcel'eecbr F%hAJitfplfat #tC1=A Boxh lo 1-4 Tenp. 5etaicWF8ecbr200Ar* T 6ery3pemT01Jddr2m400A)1p. Tarp 5WmVFesder4ol -=Amp. Temp &NmT9ee*6M4000Anv, tom �g�t tir�i! Ltnitedt�t� yr' 1 &� F+eRiA/ t�liir� l�ane€'arrttcrs F%mmbIaewWcd ate y- �li+lA tarrscxt� Thwymm Me$5,0010ra hadduawT Udi $12DX $14e, $GO $2mw $MOO $ 600 MOD $ gam $110;00 $10 $1moo $ 900 $ MID $ 12040 .$1(206 $ moo $124.86 $ 40,00 $ 74,00 $11000 pmlrirctor Informaga n N"___Protect Your Home_. W(MAdtem 3750 PrIorltv. Wav South Dr Indpls g Ind Zp . _._4624c � 086, 02��_ �1'7 6642547 �rg�y /�, PROTt= YH934RSexp,12f10l2fl73 Tt? #t31. iyUill ljitr�raei .. $ $ S� $ $__L4,00 T gi ss dd'h9d bj FM19Z ,art: (1) Omw W11 sCUW teAtuckris for t w yOrs after ibis dac" p9(r1tt €s tad. (2) 0ArfffsmqJmd to here an decd tutor if said p riy is fasWo, reef tar lee, PWdt e)0ms after six rrcnt d last 1ng)ac . After rax1rgtfeaixe r� lNvebyartlfyM1 Ianm ft ate rlc d lrislai Cxa 0r aeration In ra3rrlsit vwltfit ttre der lc l lam, RE Q, RM CtVer 19MVW, Chaper2ro46Ek11vCftyd PW Angeles fs sfdpW 1 PwM Sgnaiura of omw, ateddcet sontraeor or dectdcal adMnlsfraior: oae -Kwon Roberts coven• 03/01/2016 Application Number . . . . . 22-00000855 Date 7/12/22 Application pin number . . . 830685 Property Address . . . . . . 606 E 4TH ST ASSESSOR PARCEL NUMBER: 06-30-00-0-1-7335-0000- Application type description ELECTRICAL ONLY Subdivision Name . . . . . . Property Use . . . . . . . . Property Zoning . . . . . . . RS7 RESDNTL SINGLE FAMILY Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc DHP's ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ JESSE AHMANN EXTRA MILE TECH & ELECT., LLC 606 E 4TH ST 418 N. RACE ST. PORT ANGELES WA 98362 PORT ANGELES WA 98362 (406) 570-5095 (360) 457-5222 ---------------------------------------------------------------------------- Permit . . . . . . ELECTRICAL ALTER RESIDENTIAL Additional desc . . 1-4 CIRCUITS Permit Fee . . . . 75.00 Plan Check Fee . . .00 Issue Date . . . . 7/12/22 Valuation . . . . 0 Expiration Date . . 1/08/23 Qty Unit Charge Per Extension BASE FEE 75.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 75.00 75.00 .00 .00 Plan Check Total .00 .00 .00 .00 Grand Total 75.00 75.00 .00 .00 1 - 2 SINGLE-FAMILY ELECTRICAL PERMIT APPLICATION Pub! ic \Yorks and ULili ties Department 32 l E. 5th Street. Port ;\ngeles. WJ\ 98362 300.417.47]5 ! www.cilyofjJa us I electricalpcnnitsr21/cityofpa.us Project Address:--------------------------------------­ Project Description:--------------------------------------□Single-Family Residential D Duplex/ ARU Building Square footage: _______________ _ OWNER JNFORMATtON Name: ________________________ Email: ______________ _ Mailing Address: ________________________ Phone: ___________ _ ELECTRfCAL CONTRACTOR fNFORMATION Name: ___________________________ License: ___________ _ Mailing Address: ________________________ Expiration Date: ________ _ Email: Phone: ___________ _ PROJECT DETAILS Item Unit Charge Qy51ntit3£ :To1s.l (Quantity x Unit Charge) Service/Feeder 200 Amp. $120.00 $ Service/Feeder 201-400 Amp. $146.00 $ Service/Feeder 401-600 Amp. $205.00 $ Service/Feeder 601-1000 Amp. $262.00 $ Service/Feeder over 1000 Amp. $373.00 $ Branch Circuit W/ Service Feeder $5.00 $ Branch Circuit W/O Service Feeder $63.00 $ Each Additional Branch Circuit $5.00 $ Branch Circuits 1-4 $75.00 $ Temp. Service/Feeder 200 Amp. $93.00 $ Temp. Service/Feeder 201-400 Amp. $110.00 $ Temp. Service/Feeder 401-600 Amp. $149.00 $ Temp. Service/Feeder 601-1000 Amp. $168.00 $ Portal to Portal Hourly $96.00 $ Signal CircuiULimited Energy - 1 &2 DU. $64.00 $ Manufactured Home Connection $120.00 $ Ren ewable Elec. Energy: 5KVA System or less $102.00 $ Thermostat (Note: $5 for each additional) $56.00 $ First 1300 Sql;Jare Feet $120.00 $ Each Additional 500 square feet" $40.00 $ Each Outbuilding / Detached Garage $74.00 $ Each Swimming Pool/ Hot Tub $110.00 $ TOTAL $ Owner as defined by RCW.19.28.261: (1) Owner will occupy the structure for two years after this electrical permit is finalized. (2) Owner is required to hire an electrical contractor if above said property is for sale, rent or lease. Permit expires after six months of last inspection. After reading the above statement, I hereby certify that I am the owner of the above named property or a licensed electrical contractor. I am making the electrical installation or alteration in compliance with the electrical laws, N.E.C., RCW. Chapter 19.28, WAC. Chapter 296- 468, The City of Port Angeles Municipal Code, and Utility Specifications and PAMC 14.05.050 regarding Electrical Permit Applications. Date Print Name Signature (0 Owner D Electrical Contractor/ Administrator) [Electrical Permit Applications may be submitted to City Hall or electricalpermits@cityofpa.us] '"'CJ CD PREPARED 7/11/22, 7:15:43 PAYMENT DUE CITY OF PORT ANGELES PROGRAM BP820L --------------------------------------------------------------------------- APPLICATION NUMBER:22-00000855 606 E 4TH ST FEE DESCRIPTION AMOUNT DUE --------------------------------------------------------------------------- ELECTRICAL ALTER RESIDENTIAL 75.00 TOTAL DUE 75.00 Please present reciept to the cashier with full payment ELECTRICAL INSPECTION WIRING REPORT APPROVED NOT APPROVED DITCH ROUGH IN/COVER SERVICE FINAL COMMENTS: DHP’s NOTIFY INSPECTOR at (360) 808-2613 WHEN CORRECTIONS ARE COMPLETED WITHIN 15 DAYS DATE PERMIT # INSPECTOR 7/13/2022 22-855 TAP OWNER CONTRACTOR Extra Mile Electric PROJECT ADDRESS 606 E 4th St Application Number . . . . . 23-00000936 Date 9/05/23 Application pin number . . . 007616 Property Address . . . . . . 606 E 4TH ST ASSESSOR PARCEL NUMBER: 06-30-00-0-1-7335-0000- Application type description ELECTRICAL ONLY Subdivision Name . . . . . . Property Use . . . . . . . . Property Zoning . . . . . . . RS7 RESDNTL SINGLE FAMILY Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc PV system and service ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ JESSE AHMANN POWER TRIP ENERGY CORP. 606 E 4TH ST 83 DENNY AVE PORT ANGELES WA 98362 PORT TOWNSEND WA 98368 (406) 570-5095 (360) 643-3080 ---------------------------------------------------------------------------- Permit . . . . . . ELECTRICAL ALTER RESIDENTIAL Additional desc . . Permit Fee . . . . 240.00 Plan Check Fee . . .00 Issue Date . . . . 9/05/23 Valuation . . . . 0 Expiration Date . . 3/03/24 Qty Unit Charge Per Extension 2.00 120.0000 ECH EL-0-200 SRV FEEDER 240.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 240.00 240.00 .00 .00 Plan Check Total .00 .00 .00 .00 Grand Total 240.00 240.00 .00 .00 Public Works and Utilities Department 321 E. 5th Street, Port Angeles, WA 98362 360.417.4735 | www.cityofpa.us | electricalpermits@cityofpa.us EL1-2 SF 1 - 2 SINGLE-FAMILY ELECTRICAL PERMIT APPLICATION Project Address: Project Description: □Single-Family Residential □ Duplex / ARU Building Square footage: OWNER INFORMATION Name: Email: Mailing Address: Phone: ELECTRICAL CONTRACTOR INFORMATION Name: License: Mailing Address: Expiration Date: Email: Phone: PROJECT DETAILS Item Unit Charge Quantity Total (Quantity x Unit Charge) Service/Feeder 200 Amp.$120.00 Service/Feeder 201-400 Amp.$146.00 $ Service/Feeder 401-600 Amp.$205.00 $ Service/Feeder 601-1000 Amp.$262.00 $ Service/Feeder over 1000 Amp.$373.00 $ Branch Circuit W/ Service Feeder $5.00 $ Branch Circuit W/O Service Feeder $63.00 $ Each Additional Branch Circuit $5.00 $ Branch Circuits 1-4 $75.00 $ Temp. Service/Feeder 200 Amp.$93.00 $ Temp. Service/Feeder 201-400 Amp.$110.00 $ Temp. Service/Feeder 401-600 Amp.$149.00 $ Temp. Service/Feeder 601-1000 Amp.$168.00 $ Portal to Portal Hourly $96.00 $ Signal Circuit/Limited Energy - 1&2 DU.$64.00 $ Manufactured Home Connection $120.00 $ Renewable Elec. Energy: 5KVA System or less $102.00 $ Thermostat (Note: $5 for each additional)$56.00 $ First 1300 Square Feet $120.00 $ Each Additional 500 square feet``$40.00 $ Each Outbuilding / Detached Garage $74.00 $ Each Swimming Pool / Hot Tub $110.00 $ TOTAL $ Owner as defined by RCW.19.28.261: (1) Owner will occupy the structure for two years after this electrical permit is finalized. (2) Owner is required to hire an electrical contractor if above said property is for sale, rent or lease. Permit expires after six months of last inspection. After reading the above statement, I hereby certify that I am the owner of the above named property or a licensed electrical contractor. I am making the electrical installation or alteration in compliance with the electrical laws, N.E.C., RCW. Chapter 19.28, WAC. Chapter 296- 46B, The City of Port Angeles Municipal Code, and Utility Specifications and PAMC 14.05.050 regarding Electrical Permit Applications. Date Print Name Signature (□Owner □Electrical Contractor / Administrator) Pe r m i t # : New Construction Only [Electrical Permit Applications may be submitted to City Hall or electricalpermits@cityofpa.us or faxed to 360.417.4711] 606 E 4th St Port Angeles, WA 98362 6.96 kW Grid-Tied Roof-Mounted PV Jesse Ahmann montanacellist@gmail.com 606 E 4th St Port Angeles, WA 98362 (406) 570-5095 Power Trip Energy POWERTE964JN 4-15-202483 Denny Ave Port Townsend, WA 98368 buddy@powertripenergy.com (360) 643-3080 $ 8/31/2023 Andy Cochrane 240.00 2 240.00 Public Works and Utilities Department 321 E. 5th Street, Port Angeles, WA 98362 360.417.4735 | www.cityofpa.us | electricalpermits@cityofpa.us EL1-2 SF 1 - 2 SINGLE-FAMILY ELECTRICAL PERMIT APPLICATION Project Address: Project Description: □Single-Family Residential □ Duplex / ARU Building Square footage: OWNER INFORMATION Name: Email: Mailing Address: Phone: ELECTRICAL CONTRACTOR INFORMATION Name: License: Mailing Address: Expiration Date: Email: Phone: PROJECT DETAILS Item Unit Charge Quantity Total (Quantity x Unit Charge) Service/Feeder 200 Amp.$120.00 Service/Feeder 201-400 Amp.$146.00 $ Service/Feeder 401-600 Amp.$205.00 $ Service/Feeder 601-1000 Amp.$262.00 $ Service/Feeder over 1000 Amp.$373.00 $ Branch Circuit W/ Service Feeder $5.00 $ Branch Circuit W/O Service Feeder $63.00 $ Each Additional Branch Circuit $5.00 $ Branch Circuits 1-4 $75.00 $ Temp. Service/Feeder 200 Amp.$93.00 $ Temp. Service/Feeder 201-400 Amp.$110.00 $ Temp. Service/Feeder 401-600 Amp.$149.00 $ Temp. Service/Feeder 601-1000 Amp.$168.00 $ Portal to Portal Hourly $96.00 $ Signal Circuit/Limited Energy - 1&2 DU.$64.00 $ Manufactured Home Connection $120.00 $ Renewable Elec. Energy: 5KVA System or less $102.00 $ Thermostat (Note: $5 for each additional)$56.00 $ First 1300 Square Feet $120.00 $ Each Additional 500 square feet``$40.00 $ Each Outbuilding / Detached Garage $74.00 $ Each Swimming Pool / Hot Tub $110.00 $ TOTAL $ Owner as defined by RCW.19.28.261: (1) Owner will occupy the structure for two years after this electrical permit is finalized. (2) Owner is required to hire an electrical contractor if above said property is for sale, rent or lease. Permit expires after six months of last inspection. After reading the above statement, I hereby certify that I am the owner of the above named property or a licensed electrical contractor. I am making the electrical installation or alteration in compliance with the electrical laws, N.E.C., RCW. Chapter 19.28, WAC. Chapter 296- 46B, The City of Port Angeles Municipal Code, and Utility Specifications and PAMC 14.05.050 regarding Electrical Permit Applications. Date Print Name Signature (□Owner □Electrical Contractor / Administrator) Pe r m i t # : New Construction Only [Electrical Permit Applications may be submitted to City Hall or electricalpermits@cityofpa.us or faxed to 360.417.4711] 606 E 4th St Port Angeles, WA 98362 6.96 kW Grid-Tied Roof-Mounted PV Jesse Ahmann montanacellist@gmail.com 606 E 4th St Port Angeles, WA 98362 (406) 570-5095 Power Trip Energy POWERTE964JN 4-15-202483 Denny Ave Port Townsend, WA 98368 buddy@powertripenergy.com (360) 643-3080 $ 8/31/2023 Andy Cochrane 120.00 1 120.00 Solar Agent: Rodney Just Client Name: Ahmann Residence August 1, 2023 - 3 - Power Trip Energy Corp 83 Denny Ave, Port Townsend, WA 98368 (360)643-3080 www.powertripenergy.com LIC: POWERTE964JN Project: Ahmann Residence Client: Jesse Ahmann Phone: (406) 570-5095 Address: 606 E 4th St. Port Angeles, WA 98362 System Description: 6.96 Residential Grid-tied PV AC Circuit Combiner Panel: South Exterior Wall on Home Solar Modules: Branch Circuit A - 10 Modules Model: SPR-M435-WHT-AC Micro inverter max power output 384 watts Roof of Home Net Meter: South Exterior Wall on Home Meter #: E13278 Utility Grid: City of Port Angeles AC System Disconnect: (For Rapid Shutdown of AC Modules) South Exterior Wall on Home Main Service Panel (LOAD): South Exterior Wall on Home – Meter Main Solar Modules: Branch Circuit B - 6 Modules Model: SPR-M435-WHT-AC Micro inverter max power output 384 watts Roof of Home Solar Agent: Rodney Just Client Name: Ahmann Residence August 1, 2023 - 4 - Power Trip Energy Corp 83 Denny Ave Port Townsend, WA 98368 (360)643-3080 www.powertripenergy.com LIC: POWERTE964JN Project: Ahmann Residence Client: Jesse Ahmann Phone: (406) 570-5095 Address: 606 E 4th St. Port Angeles, WA 98362 System Description: 6.96 Residential Grid-tied PV Project Photos and Notes: Home Roof – Location of 16 SunPower 435 watt modules Solar Agent: Rodney Just Client Name: Ahmann Residence August 1, 2023 - 5 - South Exterior on Home – Location of AC Disconnect, Combiner Panel, Data Monitoring South Exterior on Home– Location of Utility Meter (To be lowered and replaced with CH Meter Main) South Interior Wall in Home – Location of Electrical Panel Solar Agent: Rodney Just Client Name: Ahmann Residence August 1, 2023 - 6 - South Interior Wall in Home – Location of Electrical Panel (To be replaced with a Cutler Hammer CH42 225A panel) Solar Agent: Rodney Just Client Name: Ahmann Residence August 1, 2023 - 7 - Solar Agent: Rodney Just Client Name: Ahmann Residence August 1, 2023 - 8 - South East Roof Face of Home – Location of 16 SunPower 435 Watt Modules South Exterior Wall on Home – Location of Utility Meter South Exterior Wall on Home – Location of AC Disconnect, Data Monitoring, Combiner Panel South Interior wall in Home – Location of Electrical Panel SunPower® Maxeon® Technology Built specifically for use with the SunPower Equinox® system, the only fully integrated solar solution designed, engineered, and warranted by one company. Highest Power AC Density Available. The patented, solid-copper foundation Maxeon Gen 6 cell is over 5% larger than prior generations, delivering the highest efficiency AC solar panel available.1 Highest Lifetime Energy and Savings Designed to deliver 60% more energy over 25 years in real-world conditions like partial shade and high temperatures.2 Best Reliability, Best Warranty With more than 42.6 million and 15 GW modules deployed around the world, SunPower technology is proven to last. That’s why we stand behind our module and microinverter with the industry’s best 25-year Combined Power and Product Warranty. Datasheet 0510 15 20 25 150% 140% 130% 120% 110% 100% 90% 80% 70% 60%25 - y e a r E n e r g y Y i e l d p e r W a t t Years of Operation Up to 60% More Lifetime Energy Conventional Panel M-Series Part of the SunPower Equinox® Solar System • Compatible with mySunPowerTM monitoring • Seamless aesthetics Factory-integrated Microinverter • Highest-power integrated AC module in solar • Engineered and calibrated by SunPower for SunPower AC modules 6. 3 7 i n [1 6 1 . 7 m m ] 6. 5 4 i n [1 6 6 m m ] 5% larger 420-440W Residential AC Module M-Series: M440 | M435 | M430 | M425 | M420 SunPower® Residential AC Module 1 Based on datasheet review of websites of top 20 manufacturers per Wood Mackenzie US PV Leaderboard Q3 2021. 2 Maxeon 435 W, 22.5% efficient, compared to a Conventional Panel on same-sized arrays (260 W, 16% efficient, approx. 1.6 m²), 7.9% more energy per watt (based on PVSyst pan files for avg. US climate), 0.5%/yr slower degradation rate (Jordan, et. al. “Robust PV Degradation Methodology and Application.”PVSC 2018). 3 Voltage range can be extended beyond nominal if required by the utility. 4 Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. 5 Factory set to IEEE 1547a-2014 default settings. CA Rule 21 default settings profile set during commissioning. 6 Standard Test Conditions (1000 W/m² irradiance, AM 1.5, 25°C). All DC voltage is fully contained within the module. 7 UL Listed as PVRSE and conforms with NEC 2014 and NEC 2017 690.12; and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors; when installed according to manufacturer’s instructions. 8 Please read the safety and installation instructions for more information regarding load ratings and mounting configurations. See www.sunpower.com/company for more reference information. Specifications included in this datasheet are subject to change without notice. ©2022 SunPower Corporation. All rights reserved. SUNPOWER, the SUNPOWER logo, EQUINOX and MYSUNPOWER are trademarks or registered trademarks of SunPower Corporation in the U.S. MAXEON is a registered trademark of Maxeon Solar Technologies, Ltd. For more information visit www.maxeon.com/legal. AC Electrical Data Inverter Model: Type H (Enphase IQ7HS)@240 VAC @208 VAC Max. Continuous Output Power (VA)384 369 Nom. (L–L) Voltage/Range3 (V)240 / 211–264 208 / 183–229 Max. Continuous Output Current (Arms)1.60 1.77 Max. Units per 20 A (L–L) Branch Circuit4 10 9 CEC Weighted Efficiency 97.0%96.5% Nom. Frequency 60 Hz Extended Frequency Range 47–68 Hz AC Short Circuit Fault Current Over 3 Cycles 4.82 A rms Overvoltage Class AC Port III AC Port Backfeed Current 18 mA Power Factor Setting 1.0 Power Factor (adjustable)0.85 (inductive) / 0.85 (capacitive) DC Power Data SPR-M440- H-AC SPR-M435- H-AC SPR-M430- H-AC SPR-M425- H-AC SPR-M420- H-AC Nom. Power6 (Pnom) W 440 435 430 425 420 Power Tolerance +5/−0% Module Efficiency 22.8%22.5%22.3%22.0%21.7% Temp. Coef. (Power)−0.29% / °C Shade Tolerance Integrated module-level max. power point tracking Tested Operating Conditions Operating Temp.-40° F to +185°F (-40°C to +85°C) Max. Ambient Temp.122°F (50°C) Max. Test Load8 Wind: 125 psf, 6000 Pa, 611 kg/m² back Snow: 187 psf, 9000 Pa, 917 kg/m² front Max. Design Load Wind: 75 psf, 3600 Pa, 367 kg/m² back Snow: 125 psf, 6000 Pa, 611 kg/m² front Impact Resistance 1 inch (25 mm) diameter hail at 52 mph (23 m/s) Mechanical Data Solar Cells 66 Maxeon Gen 6 Front Glass High-transmission tempered glass with anti-reflective coating Environmental Rating Outdoor rated Frame Class 1 black anodized (highest AAMA rating) Weight 48 lb (21.8 kg) Recommended Max. Module Spacing 1.3 in. (33 mm) Warranties, Certifications, and Compliance Warranties • 25-year limited power warranty • 25-year limited product warranty Certifications and Compliance • UL 1741 / IEEE-1547 • UL 1741 AC Module (Type 2 fire rated) • UL 61730 • UL 62109-1 / IEC 62109-2 • FCC Part 15 Class B • ICES-0003 Class B • CAN/CSA-C22.2 NO. 107.1-01 • CA Rule 21 (UL 1741 SA)5 (includes Volt/Var and Reactive Power Priority) • UL Listed PV Rapid Shutdown Equipment7 Enables installation in accordance with: • NEC 690.6 (AC module) • NEC 690.12 Rapid Shutdown (inside and outside the array) • NEC 690.15 AC Connectors, 690.33(A)–(E)(1) When used with AC module Q Cables and accessories (UL 6703 and UL 2238)7: • Rated for load break disconnect PID Test 1000 V: IEC 62804 Packaging Configuration Modules per pallet 25 Packaging box dimensions 75.4 × 42.2 × 48.0 in. (1915 × 1072 × 1220 mm) Pallet gross weight 1300.7 lb (590 kg) Pallets per container 32 Net weight per container 41,623 lb (18,880 kg) 1-800-SUNPOWER | sunpower.com 539973 RevB January 2022 Please read the safety and installation instructions for details. ELECTRICAL INSPECTION WIRING REPORT APPROVED NOT APPROVED DITCH ROUGH IN/COVER SERVICE FINAL COMMENTS 1. EMT connectors shall be made tight. NEC 358.42 2. Label rated AC output and operating voltage required. NEC 690.54 3. Label emergency service disconnect required. NEC 230.85 NOTIFY INSPECTOR at (360) 808-2613 WHEN CORRECTIONS ARE COMPLETED WITHIN 15 DAYS DATE PERMIT # INSPECTOR 10/13/2023 23-936 TAP OWNER CONTRACTOR Power Trip Energy PROJECT ADDRESS 606 E 4th St ELECTRICAL INSPECTION WIRING REPORT APPROVED NOT APPROVED DITCH ROUGH IN / COVER SERVICE FINAL CORRECTIONS NEEDED: NOTIFY INSPECTOR at (360) 808-2613 WHEN CORRECTIONS ARE COMPLETED WITHIN 15 DAYS DATE PERMIT # INSPECTOR 12/3/2024 24-936 TMC OWNER Contractor Power Trip ADDRESS 606 E 4th St