Loading...
HomeMy WebLinkAbout1319 Campbell Ave - BuildingApplication Number . . . . . 22-00001189 Date 9/22/22 Application pin number . . . 603190 Property Address . . . . . . 1319 CAMPBELL AVE ASSESSOR PARCEL NUMBER: 06-30-14-5-3-0442-0000- Application type description ELECTRICAL ONLY Subdivision Name . . . . . . Property Use . . . . . . . . Property Zoning . . . . . . . RESIDENTIAL HIGH DENSITY Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc Feeder for hot tub ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ JERRY SAUNDERS JOHNSON ELECTRIC COMPANY 1319 CAMPBELL AVE 3129 S REGENT PORT ANGELES WA 98362 PORT ANGELES WA 98362 (360) 728-4327 ---------------------------------------------------------------------------- Permit . . . . . . ELECTRICAL ALTER RESIDENTIAL Additional desc . . Permit Fee . . . . 145.00 Plan Check Fee . . .00 Issue Date . . . . 9/22/22 Valuation . . . . 0 Expiration Date . . 3/21/23 Qty Unit Charge Per Extension 5.00 5.0000 ECH EL-ECH ADDNT BRANCH CIRCUIT 25.00 1.00 120.0000 ECH EL-0-200 SRV FEEDER 120.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 145.00 145.00 .00 .00 Plan Check Total .00 .00 .00 .00 Grand Total 145.00 145.00 .00 .00 1 - 2 SINGLE-FAMILY ELECTRICAL PERMIT APPLICATION Pub! ic \Yorks and ULili ties Department 32 l E. 5th Street. Port ;\ngeles. WJ\ 98362 300.417.47]5 ! www.cilyofjJa us I electricalpcnnitsr21/cityofpa.us Project Address:--------------------------------------­ Project Description:--------------------------------------□Single-Family Residential D Duplex/ ARU Building Square footage: _______________ _ OWNER JNFORMATtON Name: ________________________ Email: ______________ _ Mailing Address: ________________________ Phone: ___________ _ ELECTRfCAL CONTRACTOR fNFORMATION Name: ___________________________ License: ___________ _ Mailing Address: ________________________ Expiration Date: ________ _ Email: Phone: ___________ _ PROJECT DETAILS Item Unit Charge Qy51ntit3£ :To1s.l (Quantity x Unit Charge) Service/Feeder 200 Amp. $120.00 $ Service/Feeder 201-400 Amp. $146.00 $ Service/Feeder 401-600 Amp. $205.00 $ Service/Feeder 601-1000 Amp. $262.00 $ Service/Feeder over 1000 Amp. $373.00 $ Branch Circuit W/ Service Feeder $5.00 $ Branch Circuit W/O Service Feeder $63.00 $ Each Additional Branch Circuit $5.00 $ Branch Circuits 1-4 $75.00 $ Temp. Service/Feeder 200 Amp. $93.00 $ Temp. Service/Feeder 201-400 Amp. $110.00 $ Temp. Service/Feeder 401-600 Amp. $149.00 $ Temp. Service/Feeder 601-1000 Amp. $168.00 $ Portal to Portal Hourly $96.00 $ Signal CircuiULimited Energy - 1 &2 DU. $64.00 $ Manufactured Home Connection $120.00 $ Ren ewable Elec. Energy: 5KVA System or less $102.00 $ Thermostat (Note: $5 for each additional) $56.00 $ First 1300 Sql;Jare Feet $120.00 $ Each Additional 500 square feet" $40.00 $ Each Outbuilding / Detached Garage $74.00 $ Each Swimming Pool/ Hot Tub $110.00 $ TOTAL $ Owner as defined by RCW.19.28.261: (1) Owner will occupy the structure for two years after this electrical permit is finalized. (2) Owner is required to hire an electrical contractor if above said property is for sale, rent or lease. Permit expires after six months of last inspection. After reading the above statement, I hereby certify that I am the owner of the above named property or a licensed electrical contractor. I am making the electrical installation or alteration in compliance with the electrical laws, N.E.C., RCW. Chapter 19.28, WAC. Chapter 296- 468, The City of Port Angeles Municipal Code, and Utility Specifications and PAMC 14.05.050 regarding Electrical Permit Applications. Date Print Name Signature (0 Owner D Electrical Contractor/ Administrator) [Electrical Permit Applications may be submitted to City Hall or electricalpermits@cityofpa.us] '"'CJ CD PREPARED 9/21/22,13:38:31 PAYMENT DUE CITY OF PORT ANGELES PROGRAM BP820L --------------------------------------------------------------------------- APPLICATION NUMBER:22-00001189 1319 CAMPBELL AVE FEE DESCRIPTION AMOUNT DUE --------------------------------------------------------------------------- ELECTRICAL ALTER RESIDENTIAL 145.00 TOTAL DUE 145.00 Please present reciept to the cashier with full payment Application Number . . . . . 23-00001107 Date 10/13/23 Application pin number . . . 198829 Property Address . . . . . . 1319 CAMPBELL AVE ASSESSOR PARCEL NUMBER: 06-30-14-5-3-0442-0000- Application type description ELECTRICAL ONLY Subdivision Name . . . . . . Property Use . . . . . . . . Property Zoning . . . . . . . RESIDENTIAL HIGH DENSITY Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc PV system ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ JERRY SAUNDERS SOLGEN POWER LLC 1319 CAMPBELL AVE 5715 BEDFORD STREET PORT ANGELES WA 98362 PASCO WA 99301 (509) 931-1663 ---------------------------------------------------------------------------- Permit . . . . . . ELECTRICAL ALTER RESIDENTIAL Additional desc . . Permit Fee . . . . 240.00 Plan Check Fee . . .00 Issue Date . . . . 10/13/23 Valuation . . . . 0 Expiration Date . . 4/10/24 Qty Unit Charge Per Extension 2.00 120.0000 ECH EL-0-200 SRV FEEDER 240.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 240.00 240.00 .00 .00 Plan Check Total .00 .00 .00 .00 Grand Total 240.00 240.00 .00 .00 Public Works and Utilities Department 321 E. 5th Street, Port Angeles, WA 98362 360.417.4735 | www.cityofpa.us | electricalpermits@cityofpa.us EL1-2 SF 1 - 2 SINGLE-FAMILY ELECTRICAL PERMIT APPLICATION Project Address: Project Description: □ Single-Family Residential □ Duplex / ARU Building Square footage: OWNER INFORMATION Name: Email: Mailing Address: Phone: ELECTRICAL CONTRACTOR INFORMATION Name: License: Mailing Address: Expiration Date: Email: Phone: PROJECT DETAILS Item Unit Charge Quantity Total (Quantity x Unit Charge) Service/Feeder 200 Amp.$120.00 $ Service/Feeder 201-400 Amp.$146.00 $ Service/Feeder 401-600 Amp.$205.00 $ Service/Feeder 601-1000 Amp.$262.00 $ Service/Feeder over 1000 Amp.$373.00 $ Branch Circuit W/ Service Feeder $5.00 $ Branch Circuit W/O Service Feeder $63.00 $ Each Additional Branch Circuit $5.00 $ Branch Circuits 1-4 $75.00 $ Temp. Service/Feeder 200 Amp.$93.00 $ Temp. Service/Feeder 201-400 Amp.$110.00 $ Temp. Service/Feeder 401-600 Amp.$149.00 $ Temp. Service/Feeder 601-1000 Amp.$168.00 $ Portal to Portal Hourly $96.00 $ Signal Circuit/Limited Energy - 1&2 DU.$64.00 $ Manufactured Home Connection $120.00 $ Renewable Elec. Energy: 5KVA System or less $102.00 $ Thermostat (Note: $5 for each additional)$56.00 $ First 1300 Square Feet $120.00 $ Each Additional 500 square feet``$40.00 $ Each Outbuilding / Detached Garage $74.00 $ Each Swimming Pool / Hot Tub $110.00 $ TOTAL $ Owner as defined by RCW.19.28.261: (1) Owner will occupy the structure for two years after this electrical permit is finalized. (2) Owner is required to hire an electrical contractor if above said property is for sale, rent or lease. Permit expires after six months of last inspection. After reading the above statement, I hereby certify that I am the owner of the above named property or a licensed electrical contractor. I am making the electrical installation or alteration in compliance with the electrical laws, N.E.C., RCW. Chapter 19.28, WAC. Chapter 296- 46B, The City of Port Angeles Municipal Code, and Utility Specifications and PAMC 14.05.050 regarding Electrical Permit Applications. Date Print Name Signature (□ Owner □ Electrical Contractor / Administrator) Pe r m i t # : New Construction Only [Electrical Permit Applications may be submitted to City Hall or electricalpermits@cityofpa.us or faxed to 360.417.4711] Jerry Saunders 1319 Campbell Ave, Port Angeles, WA 98362 DRAWN BY: DATE:09/10/2023 JB DESIGN SOLGEN POWER 5715 BEDFORD ST, PASCO, WA 99301 P: 509-931-1663 1 PAGE #PV 1 A B C D E F G H 1 2 3 4 5 5 4 3 2 1 GENERAL NOTES 1. PRIOR TO THE COMMENCEMENT OF ANY WORK, THE CONTRACTOR SHALL NOTIFY THE DESIGNER OF ANY DISCREPANCIES WITH THE DESIGN IN ANY CAPACITY. ESPECIALLY RECOMMENDATIONS, CODES, OR REGULATIONS & RULES OF THE AUTHORITY HAVING JURISDICTION, WHICH SUPERSEDED THE NEC. 2. ALL DIMENSIONS TO BE VERIFIED BY CONTRACTOR PRIOR TO COMMENCEMENT OF WORK. 3. CONTRACTOR IS RESPONSIBLE FOR ALL SAFETY PRECAUTIONS, OSHA REQUIREMENTS ETC. FOR THE SITE, INCLUDING EXISTING SITE HAZARDS. 4. SYSTEM IS GRID INTERACTIVE/INTERTIED VIA A UL LISTED POWER-CONDITIONING INVERTER. 5. SYSTEM HAS NO ENERGY STORAGE OF ANY KIND, OR UPS. 6. ALL SOLAR MOUNTING FRAMEWORK TO BE GROUNDED. 7. FOLLOW MANUFACTURERS SUGGESTED INSTALLATION PRACTICES AND WIRING SPECIFICATIONS. 8. ALL WORK TO BE IN COMPLIANCE WITH THE INTERNATIONAL BUILDING CODES. (IBC) 9. ALL ELECTRICAL WORK TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE (NEC). ELECTRICAL NOTES 1. WHERE ALL TERMINALS OF THE DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, A SIGN WILL BE PROVIDED WARNING OF THE HAZARDS. (PER ART. 690.17) 2. EACH UNGROUNDED CONDUCTOR OF THE MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY PHASE AND SYSTEM. (PER ART. 210.5) 3. A NATIONALLY RECOGNIZED TESTING LABORATORY SHALL LIST ALL EQUIPMENT IN COMPLIANCE WITH ARTICLE 110.3. 4. ALL WIRES SHALL BE PROVIDED WITH STRAIN RELIEF AT ALL ENTRY POINTS INTO BOXES AS REQUIRED BY UL LISTING 5. MODULE FRAMES SHALL BE GROUNDED AT THE UL-LISTED LOCATION PROVIDED BY THE MANUFACTURER USING UL-LISTED GROUNDING HARDWARE. 6. MODULE FRAMES, RAIL, AND POSTS SHALL BE BONDED WITH EQUIPMENT GROUND CONDUCTORS AND GROUNDED AT THE MAIN ELECTRICAL PANEL. AERIAL VIEW RESIDENCE PHOTO SHEET INDEX PV 1 COVER PAGE PV 2 SITE PLAN PV 3 ELECTRICAL DIAGRAM PV 6 PLACARD CONFIDENTIAL - THE INFORMATION CONTAINED IN THIS PACKET AND SUBSEQUENT CUTSHEETS SHALL NOT BE USED FOR THE BENEFIT OF ANYONE OUTSIDE SOLGEN POWER. NEITHER SHALL IT BE DISCLOSED TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT WRITTEN CONSENT FROM SOLGEN POWER. CUT SHEETS ATTACHED PV 4 CHIKO MOUNTING PV 5 MOUNTING DIAGRAM 7. THE DC GROUNDING ELECTRODE CONDUCTOR SHALL BE SIZED ACCORDING TO ARTICLE 250.166B & 690.47. 10/9/2023 STRUCTURAL ONLY SYSTEM SUMMARY: (N) 21 - ZNSHINE ZXM6-NH120-360M (360W) MODULES (N) 3 - HOYMILES HM1200 MICRO INVERTERS (N) 4 - HOYMILES HM600 MICRO INVERTERS (N) 1 - HOYMILES HM300 MICRO INVERTERS (N) 1 - 125A PV LOAD CENTER (N) 1 - 60A SQUARE D NON FUSED AC DISCONNECT [240V] (N) JUNCTION BOX (E) 200A MAIN SERVICE PANEL WITH (E) 200A MAIN BREAKER N EW S INDEX: NUMBER OF MODULES:21 MODULE TYPE: INVERTER: MODULES MAIN SERVICE ZNSHINE ZXM6-NH120-360M Hoymiles Series 3 COMBINER BOX 4 1 24" O.C. 2" x 4" TRUSS SPACING: TRUSS SIZE: SYSTEM SIZE DC: SYSTEM SIZE AC: SYSTEM SIZE DC:7.560kW SYSTEM SIZE AC:6.300kW SYSTEM SIZE DC: SYSTEM SIZE AC: AC DISCONNECT 5 UTILITY METER 2 3'3' 3'3' 3' 3' 3'3' 3' Jerry Saunders 1319 Campbell Ave, Port Angeles, WA 98362 DRAWN BY: DATE:09/10/2023 JB A B C D E F G H 1 2 3 4 5 5 4 3 2 1 DESIGN 1 PAGE #PV 2 1/8" = 1'-0" DRAWING SCALE: SOLGEN POWER 5715 BEDFORD ST, PASCO, WA 99301 P: 509-931-1663 CONFIDENTIAL - THE INFORMATION CONTAINED IN THIS PACKET AND SUBSEQUENT CUTSHEETS SHALL NOT BE USED FOR THE BENEFIT OF ANYONE OUTSIDE SOLGEN POWER. NEITHER SHALL IT BE DISCLOSED TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT WRITTEN CONSENT FROM SOLGEN POWER. ROOF AREA: 1034.01Ft2 PV AREA: 412.15Ft2 ROOF %: 39.86%CIRCUIT 1 CIRCUIT 2 SOLAR OFFSET 5 4 2 3 1 IFC 2018 COMP. SHINGLE 10/9/2023 STRUCTURAL ONLY (N) UTILITY AC DISCONNECT 240V/60A NEMA 3R NON-FUSIBLE, VISIBLE-LOCKABLE LABELED (N) PV OCPD 2P - 35A (E) LOADS 200A MAIN DISCONNECT UTILITY SERVICE 120/240V SINGLE PHASE 200A RATED MAIN SERVICE PANEL L1 G N-G 35A LOAD-SIDE SOLAR OCPD (Opposite end of the main disconnect on the busbar - NEC 705.12(B)(3) FACILITY GROUND GROUND ROD NEMA3R RATED JUNCTION BOX: SHALL COMPLY W/ NEC 110.3 & 314.6 (N) 240V/60A PV 125A LOAD CENTER, NEMA 3R RATED 348 12121 8 ZNSHINE ZXM6-NH120-360M MODULES WITH HOYMILES HM-1200 MICRO INVERTERS 2 ZNSHINE ZXM6-NH120-360M MODULES WITH HOYMILES HM-600 MICRO INVERTERS 1 ZNSHINE ZXM6-NH120-360M MODULE WITH HOYMILES HM-300 MICRO INVERTER (3 OF 3)(2 OF 3)(1 OF 3) 34 1216 4 ZNSHINE ZXM6-NH120-360M MODULES WITH HOYMILES HM-1200 MICRO INVERTERS (2 OF 2) 6 ZNSHINE ZXM6-NH120-360M MODULES WITH HOYMILES HM-600 MICRO INVERTERS (1 OF 2) 2 20A 20A Jerry Saunders 1319 Campbell Ave, Port Angeles, WA 98362 DRAWN BY: DATE:09/10/2023 JB A B C D E F G H 1 2 3 4 5 5 4 3 2 1 DESIGN 1 PAGE #PV 3 NOT TO SCALE DRAWING SCALE: SOLGEN POWER 5715 BEDFORD ST, PASCO, WA 99301 P: 509-931-1663 CONFIDENTIAL - THE INFORMATION CONTAINED IN THIS PACKET AND SUBSEQUENT CUTSHEETS SHALL NOT BE USED FOR THE BENEFIT OF ANYONE OUTSIDE SOLGEN POWER. NEITHER SHALL IT BE DISCLOSED TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT WRITTEN CONSENT FROM SOLGEN POWER. COMBINER BOX PANEL SIZE CALCS NUMBER OF MODULES NOMINAL OUTPUT CURRENT TOTAL 125%CIRCUIT #BREAKER SIZETOTALNUMBER OF MICROINVERTERS COMBINED TOTAL BREAKER SIZE CALCS MAX AC OPERATING CURRENT 125% TOTAL BREAKER SIZE 26.07A x 1.25 x 32.59A =35A C 3 #8 AWG THWN-2, CU #8 AWG THWN-2, CU D** 4 #8 AWG THWN-2, CU #8 AWG THWN-2, CU * TAG A CABLE WILL BE RUN THROUGH ATTIC WHERE POSSIBLE ** TAG D ONLY IF APPLICABLE * CONDUCTOR SCHEDULE CONDUCTORS GROUND TAG ID WIRES IN CONDUIT MINIMUM WIRE SIZE TYPE, MATERIAL MINIMUM WIRE SIZE TYPE, MATERIAL A* 6 #12 AWG PV CABLE, CU #6 AWG BARE, CU B 5 #12 AWG THWN-2, CU #8 AWG THWN-2, CU MAX AC OPERATING CURRENT FOR HM-1200, 600, 300 INVERTER TYPE NUMBERR OF INVERTERS NOMINAL OUTPUT CURRENT TOTAL COMBINED TOTAL HM-1200 3 X 5.0A = 15.00A =26.07AHM-600 4 X 2.46A = 9.84A HM-300 1 X 1.23A =1.23A LOAD CALCS - TOTAL AMPS AVAILABLE BUS RATING 120%TOTAL MAIN BREAKER X = - = MAX BREAKER SIZE 200A 1.2 240 200A 40A X1CIRCUIT 1 (1 of 3)1 CIRCUIT 1 (2 of 3) CIRCUIT 1 (3 of 3)X21 == X ==8 2 2.46A1.23A 5.0A ==x 1.25 =x 1.25 = x 1.25 = 17.11A 20A 10.00A 1.23A 2.46A 1.54A 3.08A 12.50A X =6CIRCUIT 2 (1 of 2)3 CIRCUIT 2 (2 of 2)X ==4 1 2.46A 5.0A =x 1.25 =9.23A =15.48Ax1.25 =20A7.38A 5.00A 6.25A NOTES: 1. 200A UTILITY METER GLOBE ONLY. (EXISTING) 2. 200A LOAD CENTER. (EXISTING) 3. 60A RATED NON-FUSED LOCKABLE AC DISCONNECT. (NEW) 4. 125A RATED COMBINER PANEL. (NEW) ALL CONDUIT SIZES ARE MINIMUM SIZES ALL WIRE SIZES ARE FOR COPPER WIRE ALL EQUIPMENT USED SET TO ANTI ISLANDING PROFILE 1 2 3 4 NOTES: ·GAS METER LOCATED IN PROXIMITY OF THE PV INSTALLATION, LOAD CENTER, AND/OR DISCONNECTS. DISCONNECTS SHALL BE LOCATED IN COMPLIANCE WITH UTILITY AND THE AHJ (AUTHORITY HAVING JURISDICTION). PV INSTALLATION SHALL COMPLY WITH ALL APPLICABLE CODES. ·WIRE RATED AND AMPACITY CALCULATED @ 90°C FOR ROOFTOP INSTALLATION AND ATTIC RUN TO INVERTER. ·PER NEC REQUIRMENTS GROUNDING CONDUCTORS SMALLER THAN 6AWG SHALL BE PROTECTED IN A CONDUIT, RACEWAY, OR ARMORED PROTECTIVE SHEATHING (NEC 250.64). THE WORKING CLEARANCES AROUND THE EXISTING ELECTRICAL EQUIPMENT AS WELL AS THE NEW ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN ACCORDANCE WITH NEC 110.26. ANY CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT. (NEC 300.6 C1, 310.8 D). ·ROOM FOR EQUIPMENT WITHIN 5 FEET FROM MSP. ·ALL CONDUIT SHALL BE EMT 3/4" IN DIAMETER UNLESS OTHERWISE STATED. ·CONFIGURE FOR IEEE 1547 ANTI-ISLANDING GRID PROFILE Jerry Saunders 1319 Campbell Ave, Port Angeles, WA 98362 DRAWN BY: DATE:09/10/2023 JB DESIGN 1 PAGE # PV 4 A B C D E F G H 1 2 3 4 5 5 4 3 2 1 STRUCTURAL NOTES: 1. TOTAL WEIGHT (MODULE & RAIL): 1050 LBS 2. RAIL WEIGHT: 101 LBS 3. MODULE WEIGHT: 949 LBS 4. DISTRIBUTED WEIGHT: 2.62 PSF SOLGEN POWER 5715 BEDFORD ST, PASCO, WA 99301 P: 509-931-1663 CONFIDENTIAL - THE INFORMATION CONTAINED IN THIS PACKET AND SUBSEQUENT CUTSHEETS SHALL NOT BE USED FOR THE BENEFIT OF ANYONE OUTSIDE SOLGEN POWER. NEITHER SHALL IT BE DISCLOSED TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT WRITTEN CONSENT FROM SOLGEN POWER. 5' 9 " 3'5" 5'9" 0.67" 13.8' D 4' Mid Clamp End Clamp 4' 4' 14.24' Grounding Lug 6" 1.4" ROOFING SOLAR PANEL CHIKO #7 RAIL ROOF TECH MINI II L FOOT #10 x 2-1/2" HI-HWH Strong Shield Pole Gripper Screws Minimum embedment : Thickness of Sheathing A B INSTALL A OR B DECK MOUNTING RAFTER/PURLIN/TRUSS ROOF TECH MINI II DO W N S L O P E DO W N S L O P E Minimum embedment 1.5 In. 10/9/2023 STRUCTURAL ONLY 15'-9" 39'-2" 32'-5" 12' Jerry Saunders 1319 Campbell Ave, Port Angeles, WA 98362 DRAWN BY: DATE:09/10/2023 JB A B C D E F G H 1 2 3 4 5 5 4 3 2 1 DESIGN 1 PAGE #PV 5 3/16" = 1'-0" DRAWING SCALE: STRUCTURAL NOTES: 1. 48" MAX SPAN OF RAIL TO DISTRIBUTE WEIGHT OVER SUPPORT OF TRUSSES 2. MOUNTING FEET ARE IN APPROXIMATE LOCATION. 3. MOUNTING FEET SHOULD BE STAGGERED AS SHOWN IN DIAGRAM 2 MOUNTING DIAGRAM 1 MOUNTING DIAGRAM SCALE: NOT TO SCALE SOLGEN POWER 5715 BEDFORD ST, PASCO, WA 99301 P: 509-931-1663 CONFIDENTIAL - THE INFORMATION CONTAINED IN THIS PACKET AND SUBSEQUENT CUTSHEETS SHALL NOT BE USED FOR THE BENEFIT OF ANYONE OUTSIDE SOLGEN POWER. NEITHER SHALL IT BE DISCLOSED TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT WRITTEN CONSENT FROM SOLGEN POWER. MOUNTING FEET PV MODULE CHIKO #7 RAIL 48" ROOF 1 TILT:20° AZIMUTH:91° ROOF 2 TILT:20° AZIMUTH:271° 10/9/2023 STRUCTURAL ONLY N EW S Jerry Saunders 1319 Campbell Ave, Port Angeles, WA 98362 DRAWN BY: DATE:09/10/2023 JB DESIGN 1 PAGE # PV 6 A B C D E F G H 1 2 3 4 5 5 4 3 2 1 SOLGEN POWER 5715 BEDFORD ST, PASCO, WA 99301 P: 509-931-1663 CONFIDENTIAL - THE INFORMATION CONTAINED IN THIS PACKET AND SUBSEQUENT CUTSHEETS SHALL NOT BE USED FOR THE BENEFIT OF ANYONE OUTSIDE SOLGEN POWER. NEITHER SHALL IT BE DISCLOSED TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT WRITTEN CONSENT FROM SOLGEN POWER. CAUTIONPOWER TO THIS BUILDING IS SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: 6"x6" 1319 Campbell Ave, Port Angeles, WA 98362 SOLAR PV ARRAY WITH MICROINVERTERS ROOF MOUNTED UTILITY METER MAIN SERVICE PANEL AC DISCONNECT www.znshinesolar.com Anti PID Limited power degradation of ZXM6-NH120 module caused by PID effect is guaranteed under strict testing condition for mass production High Efficiency Graphene coating can increase about 2W of the module efficiency by rising around 0.5% of the light transmission ZNShine PV-Tech Co., LTD, founded in 1988, is a world-leading high-performance PV module manufacturer, PV power station developer, EPC and power station operator. With its state-of-the-art production lines, the company boasts module output of 5GW. Bloomberg has listed ZNShine as a global Tier 1 PV manufacturer and Top 4 reliable PV supplier. ZXM6-NH120 Series Znshinesolar 9BB HALF-CELL Black Mono PERC PV Module 120 Mono Poly Solutions 350W丨355W丨360W丨365W丨370W 9 Busbar Solar Cell No power loss thanks to improved temperature co-efficient caused by 9 busbar solar cell Made with selected materials and components to grant quality, dura- tion, efficiency and through outputs, the ZXM6-NH120 monocrystal- line modules by ZNSHINE SOLAR( power output 350 up to 370Wp, represent a highly flexible solution for diverse installation types, from industrial rooftop plants to small home PV systems or large ground surfaces. This allows you to produce clean energy while reducing your energy bill. ZNSHINE SOLAR’S ZXM6-NH120 Monocrystalline solar modules are tested and approved by international acknowledged laboratories, so that we can offer our customers a reliable and price-quality optimized product. The linear warranty on product outputs further ensures increased security and return on investments over time. Certified to withstand the most challenging environmental conditions 5400 Pa snow load 2400 Pa wind load Better Weak Illumination Response Lower temperature coefficient and wide spectral response, higher power output, even under low-light settings Graphene Coating Graphene coating modules can increase power generation and self-cleaning, also can save maintainance cost 9BB 12 years product warranty/25 years output warranty 0.55% Annual Degradation over 25 years Industry Standard Znshine’s Standard Wa r r a n t e d P o w e r O u t p u t 100% 97.5% 90% 80% 84.3% 1 12 15 255Years Znshinesolar 9BB HALF-CELL Black Mono PERC PV Module TEMPERATURE RATINGS 44℃ ±3℃ -0.36%/℃ -0.29%/℃ 0.05%/℃ NMOT Temperature coefficient of Pmax Temperature coefficient of Voc Temperature coefficient of Isc Maximum Power Pmax(Wp) Maximum Power Voltage Vmpp(V) Maximum Power Current Impp(A) Open Circuit Voltage Voc(V) Short Circuit Current Isc(A) *NMOT(Nominal module operating temperature):Irradiance 800W/m²,Ambient Temperature 20℃,AM 1.5,Wind Speed 1m/s *The data above is for reference only and the actual data is in accordance with the pratical testing MECHANICAL DATA PACKAGING INFORMATION 40’HQ 30 780 DIMENSION OF THE PV MODULE(mm) *STC (Standard Test Condition): Irradiance 1000W/m², Module Temperature 25℃, AM 1.5 *The data above is for reference only and the actual data is in accordance with the pratical testing ELECTRICAL PROPERTIES 丨 STC* ELECTRICAL PROPETIES 丨 NMOT* I-V CURVES OF THE PV MODULE ZXM6-NH120 Series Add : 1#, Zhixi Industrial Zone,JintanJiangsu 213251,P.R. China Tel:+86 519 6822 0233 E-mail:info@znshinesolar.com Remark: please read safety and installation instructions before using the product丨Subject to change without prior notice © ZNSHINE SOLAR 2020丨Version: ZXM6-NH120-2006.E Mono PERC 166×83mm 120(6×20) 1755×1038×35 mm 20.5 kg High transparency,low iron,tempered Glass 3.2 mm (AR-coating) IP 68,3 diodes 4 mm² ,350 mm MC4-compatible Solar cells Cells orientation Module dimension Weight Glass Junction box Cables Connectors Packing Type Piece/Box Piece/Container WORKING CONDITIONS Maximum system voltage Operating temperature Maximum series fuse Maximum load(snow/wind) 1500 V DC -40℃~+85℃ 20 A 5400 Pa / 2400 Pa Module Type Nominal Power Watt Pmax(W) Power Output Tolerance Pmax(%) Maximum Power Voltage Vmp(V) Maximum Power Current Imp(A) Open Circuit Voltage Voc(V) Short Circuit Current Isc(A) Module Efficiency (%) 365 0~+3 34.0 10.74 40.8 11.33 20.04 ZXM6- NH120-365/M 370 0~+3 34.2 10.82 41.0 11.42 20.31 ZXM6- NH120-370/M ZXM6- NH120-355/M 355 0~+3 33.6 10.57 40.4 11.14 19.49 ZXM6- NH120-350/M 350 0~+3 33.4 10.48 40.2 11.04 19.21 ZXM6- NH120-360/M 360 0~+3 33.8 10.66 40.6 11.24 19.76 267.1 31.4 8.50 37.8 9.15 270.6 31.6 8.57 38.0 9.22 256.1 30.9 8.28 37.2 8.92 259.8 31.1 8.36 37.4 9.00 263.5 31.3 8.43 37.6 9.08 40 50 30 20 10 1.000 W/m2 800 W/m2 600 W/m2 400 W/m2 200 W/m 2 3 4 5 7 6 8 9 10 Cu r r e n t ( A ) Po w e r ( W ) Voltage (V) 1 0 90 50 130 210 170 250 290 370 330 410 0 *Do not connect Fuse in Combiner Box with two or more strings in parallel connection Barcode 2 Mounting holes Label Drainage holes Barcode 1 Grounding holes Grounding identification Junction box Open Energy For All Features Description Hoymiles 4-in-1 microinverter is one of the most cost-effective module-level solar solutions, as it can support up to 4 panels at once and maximize the PV production of your installation. With the maximum DC voltage of 60 V, Hoymiles microinverter is a PV Rapid Shutdown Equipment and conforms with NEC-2017 and NEC-2020 Article 690.12 and CEC-2021 Sec 64-218. All of the three models listed are equipped with reactive power control and are compliant with IEEE 1547, UL 1741 and CA Rule21. Microinverter Datasheet HM-1200N HM-1500N Region: North America V202108 © 2021 Hoymiles Power Electronics Inc. All rights reserved. hoymiles.com sales@hoymiles.com 01 02 03 Easy installation, just plug and play With Reactive Power Control, compliant with CA Rule 21 Compliant with U.S. NEC-2017&NEC-2020 690.12 rapid shutdown 05 04 External antenna for stronger communication with DTU High reliability, NEMA 6 (IP67) enclosure, 6000 V surge protection PREPARED 10/12/23, 7:31:39 PAYMENT DUE CITY OF PORT ANGELES PROGRAM BP820L --------------------------------------------------------------------------- APPLICATION NUMBER:23-00001107 1319 CAMPBELL AVE FEE DESCRIPTION AMOUNT DUE --------------------------------------------------------------------------- ELECTRICAL ALTER RESIDENTIAL 240.00 TOTAL DUE 240.00 Please present reciept to the cashier with full payment ELECTRICAL INSPECTION WIRING REPORT APPROVED NOT APPROVED DITCH ROUGH IN/COVER SERVICE FINAL COMMENTS NOTIFY INSPECTOR at (360) 808-2613 WHEN CORRECTIONS ARE COMPLETED WITHIN 15 DAYS DATE PERMIT # INSPECTOR 2/5/2024 23-1107 TAP OWNER CONTRACTOR Solgen PROJECT ADDRESS 1319 Campbell Ave