HomeMy WebLinkAbout1626 W 12th St - Building CITY OF PORT ANGELES
DEPARTMENT OF COMMUNITY DEVELOPMENT - BUILDING DiVISION
321 EAST 5TH STREET, PORT ANGELES, WA 98362
Application N%u~ber ..... 03-00000086 Date 1/29/03
Property Address ...... 1626 W 12TH ST
ASSESSOR PARCEL NUMBER: 0630000364350000
Application description . . . MECHANICAL REPAIR
Property Zoning .......
Application valuation .... 2625
Property owner ....... JAGGER ROBERT A ~ ,~
Owner address ........ 332 WASHINGTON HARBOR RD
SEQUIM WA 983828546
()
Contractor ......... MOUNTAIN PROPANE
Permit ...... MECF~NICAL PERMIT
Permit Fee .... 57.65 Plan Check Fee . . .00
Issue Date .... 1/29/03 Valuation .... 0
Expiration Date . . 7/28/03
Qty Unit Charge Per Extension
BASE FEE 47.00
1.00 10.6500 ECH ME-NON-HAZ PIPE 1 TO 4 10.65
Fee summary Charged Paid Credited Due
Permit Fee Total 57.65 57.65 .00 .00 ~
Plan Check Total .00 .00 .00 .00 ~--
Grand Total 57.65 57.65 .00 .00 ~
,
Separate Permits are required for electrical work, SEPA, Shoreline, ESA, utilities, private and public improvements. This permit becomes
null and void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned
for a period of t 80 days after the work as commenced, or if required inspections have not been requested within '180 days from the last
inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of
laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not
presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construction.
/-
Signature of Contractor or Authorized Agent Date ~Si~nature of Owner (if (:~Nn~Li~ builder) Date
T:\PLANNING\FORMS\1102.15 [4/2002]
BUILDING PERMIT INSPECTION RECORD
CALL 417-4815 FOR BUILDING INSPECTIONS. PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. ITIS UNLAWFUL TO COVER,
INSULATE OR CONCE,4L ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT IN A CONSPICUOUS LOCATION.
KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE O~'~ '~
INSPECTION TYPE DATE ACCEPTED COMMENTS
YES I NO
FOUNDATION:
FOOTINGS
WALLS
FOUNDATION DP~INAGE
ELECTRICAL (LIGHT DEPT) SEPARATE PERMIT: #
PLUMBING
UNDER FLOOR / SLAB
ROUGH-IN
WATER LINE
GAS LINE
BACK FLOW l WATER
AIR SEAL
WALLS
CEILING
FRAMING
JOISTS / GIRDERS
SHEAR WALL
WALLS / ROOF / CEILING
DRYWALL
T-BAR
INSULATION
SLAB I
WALL / FLOOR / CEILING
MECHANICAL
HEAT PUMP
WOOD STOVE / PELLET / CHIMNEY
HOOD / DUCTS
PWUTILITIES/ SITEWORK (EngineeringDivislon) SEPARATEPERMIT#'s:
WATERLINE / METER
SEWER CONNECTION
SANITARY
STOP&4
PLANNING DEPT. SEPARATE PERMIT #'s SEPA:
PARKING/LIGHTING ESA:
LANDSCAPING SHORELINE:
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE
RESIDENTIAL DATE YES NO COMMERCIAL DATE ACCEPTED
YES NO
ELECTRICAL - LIGHT DEPT. 417-4735 ELECTRICAL
LIGHT DEPT
CONSTRUCTION R.W. / PW/ CONSTRUCTION - R.W.
ENGINEERING 417-4807 PW / ENGINEERING
FIRE 417-4653 FIKE DEPT.
PLANNING DEPT. 417-4750 PLANNING DEPT.
BUILDING 417-4815 ~ ~-O'~O'~ ~d~ 0 BUILDING
T:\PLANNING\FORMS\I I02.15 [4/2002]
CITY OF PORT ANGELES
DEPARTMENT OF PUBLIC WORKS L/
........... INSPECTION REPORT ...........
REQUEST:
Location of Work ,o be inspected /~_/0'~ L~ / v~T'~/ ~
Name of person requesting inspection ~ ~~
Address of person requesting inspection
Type of Inspection (circle appropriate one): Permit No. ~
Sewer Foundation Framing Chimney Plumbing (~nal/SewerExcav. Other
INSPECTION NOTES:
Inspected: Date Z.~.o. ~ Time 15~c~ By '~,~0c_
Remarks: ~--~_~ ¥~i'~-~'~ ~:~ ~-~c~-coc~_~. C=~ ~ ~3~ ~-r ~o ~ I.
RESTORATION REQUIRED ...... YES. NO >~
SURFACE RESTORATION:
SURFACE TYPE: [] Unimproved [~Gravel []Asphalt [~]PCC [~Other
[] Repaired by City Work Order #
[] Repaired by Permittee ~ COMPLETE
[--} No Damage Found [] INCOMPLETE
(Continue on reverse side if necessary) STREET SUPERINTENDENT (DATE)
PORT ANGELES FIRE DEPARTMENT
Installation of LP - Checklist
Site Address: I ¢. 2 ¢~ c6 ~a-c 12't',~
~ [ Date:
Permit
Inspector's Signature: .~ff'~. :.ff~ ~_
Date Initial
~.~o taqc&_ 1. Container(s) shall be listed by nationally recognized testing agency (UL,
API, ASME). A metal manufacturers name plate or stamp must be
visible (NFPA 58, Section 2-2.1.3).
2.~ t. Ct~ 2. The pressure relief valve shall be plainly marked indicating:
a. The psig at which the valve is set to start-to-leak.
b. Rated relieving capacity in cubic feet per minute of air
c. The manufacturer's name
~x 3. If subject to damage from vehicles, container(s) shall be protected by
crash rails or guards. UFC 8210, 8001.9.3; NFPA section 5 -4.2.2
· z-Z,O ~ 4. Container(s) shall be set upon a finn foundation or otherwise firmly
secured on noncombustible structural support and located in accordance
with provisions of NFPA 58.
Z.~t~ ,ran, 5. Loose or piled combustible material, weeds, or long dry grass shall not
be permitted within ten feet of any container. NFPA 58 Section 3-
2.2.2.7(b)
~..2o ~ 6. No person shall smoke within 15 feet of container(s) (UFC 8208). Posted
"No Smoking."
~.~o ioeta- 7. No per~on shall maintain any open flame device w~thin 25 feet of any
LPG gas container. UFC 8208, UFC Standard 82-1 Section 3-8
~ IIa` 8. Underground piping shall be installed with at least 18 inches of cover.
The cover may be reduced to 12 inches if exterior damage to the piping
is not likely to result (NFPA 54 Section 3-2.8.7).
FP - 23 - A (3/24/00) Page 1 of 2
Date Initial
2,-Zl~ ~ 9. All systems shall be tested and provided free of leaks. Piping outside the
building for not less than 10 psi for 15 minutes. Piping inside the
building for not less than operating pressure for 10 minutes. UMC
Chamber 13.
~.10 ~ 10. Container(s) shall be located as per UFC Table 8204-A.
Table 8204-A -- Location of Containers
Minimum separation between containers and
buildings, public ways, or lines of adjoining property
that can be built upon
Minimum Separation
Container Capacity Mounded or Aboveground Containers Between Containers
(water gallons) Underground Containers (feet) (feet)
(feet)
Less than 125 10 t~'~ None
125 to 250 10~ None
251 to 500 10 10 3
501 to 2,000 10 25 2 3
1 The following shall apply to abovegrunnd containers installed alongside buildings
a. Containers of less than a 125-gallon water capacity are allowed next to the building.
b. ASME containers of less than a 125-gallon water capacity shall be located and installed such that the discharge
from pressure-relief devices shall not terminate in or beneath buildings and shall be located at least 5 feet
horizontally from building openings below the level of such discharge.
c. The filling connection and the vent from liquid level gauges on either DOT or ASME containers ill[ed at the
point of installation shall not be less than 10 feet from exterior sources of ignition, openings into direct-vent
(sealed combustible system) appliances, or mechanical ventilation air intakes.
2 This distance is allowed to be reduced to not less than 10 feet for a single container of 1,200-gallon water capacity
or less, provided such container is at least 25 feet from other LP-gas containers of more than 125-gallon water
capacity.
Additional comments:
FP - 23 - A (3/24/00) Page 2 of 2