Loading...
HomeMy WebLinkAbout222 E 9th St - Building , , .' CITY OF PORT ANGELES LIGHT DEPARTMENT ELECTRICAL PERMIT Nl! 16601 j-'/3 jr Port Angeles, Washlngtonoom.m.moo.m._.._...m.m.m...oo..........m.m. 19..00.... In aooordance with the City Ordinance to regulate the installation. extension, or repair of elec- trical equipment In. on. or about any building or other structure In the City of Port Angeles. per- ::: ~:;''i~~;~~=O:k=U':-::~"-~-''-,,t:-~~ Owner / .?!.c.~ to/l;#:::.moomoooooom",7Y;lOO rrenantm.m.m..m..m_..oooom._moooo..n.m._..mmm.......... Wiring Contractor m~~~oom~~"!:(CBy...oooom..oo...oon.oooo.oo...m.....moomm..moo....m..... LIght Outlets..............._..............._......._ ServIce, volts ..!.'?./;j.f!..~...... Type 01 Wiring: Receptacle Outlets........................___m. No. wires ..___~___.__..______._.__________... Armored Cable ......-----.................- Dryer, KW ....oooof._....~.... .................... SIze wlres....~&:~._.. RwUnagtee'rKHWe'a"t-e"r':.'''''''' "''''~, . ..... Main fuse ...~~...._/~ ~~ Enclosure ....................................... ,/,-r- KW_...n...._............................_..... Heat' Kw.....'!.!2.,fj?.I3...X.~.. tcr Type of wiring: Entrance Cable ___m..'. Motors: sIze, volts and phase: Rigid Conduit ............___................ Metallic Tubing ........................... Current transformers: No. & Size............__.....________.__......... Ser. NO.nnn..._................._______......__... Ser. No. ...................._............._........_. Ser. No. ..........._................................. Total Load..............___..___....... Ser. No...................._......................... Remarks: mmm.:u..___.....mu..m..m:.:.u.oo"uu.~U.n...d.oo.uu.m.m..u............oou....um__..m.m..mm..mm_.mm........... Total...___..____.....___....._..._.____.... Non-Metallic .........___..___.......___..... Knob & Tube_................_.............__ RIgid Condnit ..........................._.. Metalllc Tubing ......................._.. Raceway ......................._.....__._ Circuits. Llght................___..._.m.._____.. Utility ..............._......_.....____........... Heat ___.___...__._........................._._ Range .......___..........._____...___............. Water Heater ................._............. Motor ._._......_....____......................... Dryer .....___...______..____.......................__ Furnace .__...................._.'_.___.__..__...._.. n.m..mmm.mmum.m.m.....u..mumummum..mn..........nU....u.mmm.mm..;g__.m.m...m.m.mmm.mm.mmu;oo.mu ;::.~~..~::.m___.n__m.m ::~~.~:u:~.~:~.~.~_.___ By .....lL%~~4d{:b~..,_ NOTICE-Current must n()t be turned on until Certificate of Inspection has been issued. If work Is to be con- cealed due notice must be given the Inspector so that work may be inspected before concealment. NOTIFY THE INSPECTOR BY PERMIT NUMBER WHEN READY FOR INSPECTION ELECTRICAL PERMIT N? 16601 Address....__............._......____..........................__.....__._..__.._____..___................................._.__...___._.......Date..._......____.._.._...__.......n_.._.._..._'__n.._ Owner............_____..____n..____....__........._n...._......_.._........_.n..n._.....__..._.._____.._.._..___............Tenant___..-!___..____...~~.....................__..._.._...._............. Wiring Contractor ....._...._....._..................___......_...__._..................................._________........._............... By.__............................_..._....._....._......._____.. NOTICE-Current must not be turned on until Certificate ot Inspection has been issued. If work Is to be con- cealed due notice must be given the Inspector so that work may be inspected betore.. concealment. 1M Olympic Printers, Inc. CITY OF PORT ANGELES LIGHT DEPARTMENT ELECTRICAL PERMIT N9 15454 ?' ./ Port Angeles, WaShingtonum_____________::__'-_un_____n______u_____nuuun, 192_c.s._ In accordance with the City Ordinance to regulate the installation, extension, or repair of elec- trical equipment in, on, or about any building or other structure in the City of Port Angeles, per- mission is hereby granted to do e!e~t2cal work as listed below, "'l rJ::L C! 4'a Address _uu____t;2'_mn__mumm_un1m~n___m___nnnn__um___u__munmm Occupancy_n___~,___n__m,mu_n__ , ~:~:: ~-~~~::~~~':::Z~~~::~:=~=~:':n~;:::--:::::~-:::-'------~~:::::::::::::::::::::::::::::::::::::::::::::::::: Light Outlets...m___mm__n.......__.._.._n_.n.. Service. volts _./~.'?/.:;~_~_<? Type of 'Wiring: Receptacle Outlets.._m.._...m__m__.m..... No. wires ._m_;~f....~.........m_mm. Armored Cable ........-... };/ () dtP Non-MetalUc ___....mmm.... Size WireS...n...:L..Jn..~_mnn:.~..n.... , '/ - A- Mam fuse m_.:;)&..~"_..._m_m.._ Dryer, KWI..........._nn.....__.._.____...____.___ Range, KW nn..._nnn__hnu.h.nu_ Water Heater: Enclosure m_...."~m_mm...m___m_.._ K\Ln____n___nnn_n_..nl)nn___ . /--:;J 5 0.8 Heat. RW,._.....C'n_r....n...........n._.... Type of wiring": Entrance Cable m___.........nmmmm Motors: size, volts and phase: Rigid Conduit m.nn___mm.n____.n.... MetalUc Tubing .....m......nmn.nm Current transformers: No. & Sizenn.._nn__n_....__nn_n.nn.nn Ser. NO..n....n_.......__..............__...._..... Scr. NO...........n....n_......._nn.__.._._.__.... Ser. NO..........._n_n_._..._..n....._............ Total Load..__.... Ser. NO._.....nnnnnn_nnn_nnnnnn_...... Knob & Tube. Rigid Conduit ____.m....__m..nm____h. Metallic Tubing nnnn...m..nnn..... Raceway m___nmm..m.......n............., Circuits. LighL.__.mm._____.......______..m.m Utility n_.n.........____..........n.nnnn__n. Heat Range __............._............._.._______...___ 'Water Heater ...m.........mnm______n Motor __...___..nnnnnn..............h....... Dryer_____....._______.____________.....____._.._____._ Furnace nn......n.............._n Total............____........._._........... Remarks: ___n__nm_______n/.<"'''-~cl___~~~L_n___.______nm_nmm._.____u_________m___UUnm__n.mu_m__nmnnU__.__U _;~~;~-;~~m--u------m---.mn-...;~~~~-.n~~:~;~~--m....---nmn-n----n---.---cy_ifi"~-:n:i....n.--n;1----......n $mn...n.............__m_________. No.........._.................. By ___dn_____nL:_nL~__'/.::-r:-:m~-:l&/:(-:?::?!.\.../ NOTICE-Current must not be turned on until CertifIcate of Inspection has been issued. It work Is to be con. cealed due notice must be given the Inspector 60 that work may he inspected before concealment. NOTIFY THE INSPECTOR BY PERMIT NUMBER WHEN READY FOR INSPECTION /;/ ,5- 1w!313 ELECTRICAL PERMIT N? 15454 Dale called fw?n~itan....~.ftt'nnn_mnnmmmm_mm.n...nnn..__mm_...nn.._mm......mmn_.nm......mmmm_.____mm......_n ~::;~::::yc~::~:t:~~:::::::(71:}:~~;~~:;;.::::::::::::::::::.:::::::.:::::::::::::::::::::::::::::::~::::::::::::::::::~:~:::::::~.:::::::: Total Load ......._nn___nn__nnn.__nnn_nnn_......___n.__n .__hn...._n.....__......_ ........n!.__nn..._un.............nnn_n_......._..____nn___...n__n....n........................._ 1M 3.72 Olympic Printers, Inc. Application Number . . . . . 25-00001403 Date 11/05/25 Application pin number . . . 021971 Property Address . . . . . . 222 E 9TH ST ASSESSOR PARCEL NUMBER: 06-30-00-0-2-9015-0000- Application type description ELECTRICAL ONLY Subdivision Name . . . . . . Property Use . . . . . . . . Property Zoning . . . . . . . RS7 RESDNTL SINGLE FAMILY Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc Move electrical service ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ MAZZONCINI STEVEN A OWNER PO BOX 826 PORT ANGELES WA 983620143 ---------------------------------------------------------------------------- Permit . . . . . . ELECTRICAL ALTER RESIDENTIAL Additional desc . . Permit Fee . . . . 190.20 Plan Check Fee . . .00 Issue Date . . . . 11/05/25 Valuation . . . . 0 Expiration Date . . 5/04/26 Qty Unit Charge Per Extension 1.00 190.2000 ECH EL-0-200 SRV FEEDER 190.20 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 190.20 190.20 .00 .00 Plan Check Total .00 .00 .00 .00 Grand Total 190.20 190.20 .00 .00 ELECTRICAL INSPECTION WIRING REPORT APPROVED NOT APPROVED DITCH ROUGH IN / COVER SERVICE FINAL CORRECTIONS NEEDED: The grounding electrode conductor (GEC) has been terminated at a subpanel rather than at the main service disconnect. Per the National Electrical Code (NEC), the grounding electrode system must be connected only at the service equipment where the neutral-to-ground bond is made. Subpanels are required to have isolated neutral and ground conductors and shall not contain a neutral-to-ground bond or separate grounding electrode connection. Code References: • NEC 250.24(A)(1): “The connection of the grounding electrode conductor shall be made at any accessible point from the load end of the service drop or lateral to and including the terminal or bus to which the grounded service conductor is connected at the service disconnecting means.” DATE PERMIT # INSPECTOR 11/5/2025 25-1403 TMC OWNER Jaisheel Lawrence Contractor Sequim Valley Electric, Inc. ADDRESS 222 E 9th St ELECTRICAL INSPECTION WIRING REPORT • NEC Exhibit 250.7 and 250.8: These illustrations clarify that the grounding electrode system connection and neutral-to- ground bonding occur only at the service equipment. Subpanels must maintain isolated neutrals and grounds. Hazard / Concern: Improper bonding and grounding can result in parallel current paths on grounding conductors, potential shock hazards, and interference with overcurrent protective device operation. Correction needed: Relocate the grounding electrode conductor (GEC) to terminate at the main service disconnect enclosure. Ensure that all subpanels have isolated neutral bars and separate equipment grounding conductors. Verify that only the main service equipment contains the neutral-to- ground bond. NOTIFY INSPECTOR at (360) 808-2613 WHEN CORRECTIONS ARE COMPLETED WITHIN 15 DAYS ELECTRICAL INSPECTION WIRING REPORT APPROVED NOT APPROVED DITCH ROUGH IN/COVER SERVICE FINAL COMMENTS: NOTIFY INSPECTOR at (360) 808-2613 WHEN CORRECTIONS ARE COMPLETED WITHIN 15 DAYS DATE PERMIT # INSPECTOR 11/6/25 25-1403 TAP OWNER CONTRACTOR Sequim Valley Electric PROJECT ADDRESS 222 E 9th St