Loading...
HomeMy WebLinkAbout419 E 10th St - Building f -- '~'~ ~ .w CITY OF PORT ANGELES PUBLIC WORKS - ELECTRICAL DIVISION J21 EAST 5TH STREET. PORT ANGELES. WA 98J62 ELECTRICAL PERMIT Issued: 4/27/98 Permit No: 6293 OWNER/APPLICANT------------------------PROPERTY LOCATION------------------------ TONI RUNNION 419 10TH ST E 419 E. 10TH Lot: Port Angeles, WA 98362 Block: Long Legal: . 360/457-5009 Sub: T: S: Parc No: CONTRACTOR-----------------------------DESIGNER--------------------------------- ELECTRIC SERVICE 924 DRAPER RD. PORT ANGELES, WA 98362 360/452-6424 , 000/000-0000 PROJECT INFO------------------------~------------------------------------------- prj Type: RES. MISC. prj Value: $0.00 Occ Type: Cnstr Type: ADD CIRCUITS Occ Grp: Occ Load: Land Use: Electrical Heat Service Type Baseboard KW: 0 Riser Voltage: 120,240 Furnace KW: 0 X Overhead Service Diameter: X-l -3 Heat Pump KW: 0 Underground Service Service Size: 200 AMPS X Fan/Wall KW: 2 Temp Service Feeder Size: 0 AMPS PROJECT NOTES------------------------------------------------------------------- WIRE CIRCUITS PER PA HOUSING REHAB PROJECT FEES ASSESSMENT----------------------------------------------------~---- Service: $0.00 Additional Feeders: $0.00 Circuit Wiring: $41.00 Temp Service: $0.00 $0.00 Misc TOTAL FEE: Amount Paid: $41.00 $41. 00 --------------------------------- --------------------------------- TOTAL FEE: $41.00 Balance Due: $0.00 COMMENTS/ACTION NEEDED .. ELECTRICAL PERMIT INSPECTION RECORD CALL 4174735 FOR ELECTRICAL INSPECTIONS. PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLA WFUL TO COVEl/, INSULA TE OR CONCEAL ANY WORK BEFORE IT IS INSPECTED AND ACCEF17:.:D. KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE INSPECTION TYPE DATE ACCJtPTED COMMINI'S YES I NO UllCt1 -IN I ~HVI('F l<TN .& T I &)'/.;11/9A" I I GENERAL COMMENTS: rw-I 101.1' 14196) , I I I .. r."t -,., ~ HOUSING -PRESERVATION andRERABILITATION PROGRAMS Poit Angeles Housing Rehabilitation Program 106 North Lincoln Street Port Angeles, WA 98362 Telepbone (360)452-2023/ (360) 452-2137 FAX (360) 452-1618 Date: April 2, 199B Worklist specifications for: Toni RQnnion (96PA7'l E) 419 E -10th Street Port Angeles, WA 9B362 Telephone (360)457-5009 PROJECT A (HEALTH AND SAFETY REPAIRS) 1600 l}Install new hardwired smoke alarms with battery backup throughout the house to code. Alarms to be inter-tied. 2)Safe up electrical wiring, outlets. fixtures, junction boxes and connections throughout the house. All fixtures and connections to have proper junction boxes. Insure that all 3-prong outlets are properly grounded and that all other outlets have proper polarity. Insure that all open junction boxes, switches and ou~lets have cover plates. Properly attach all loose romex wiring in the crawl space. Insure that the service panel is properly wired and labeled. Install proper tie-downs to secure the OVerhead mast at the rear service entry. 3)Insure that all existing outlets and switches are working. Include replacement of all defective outlets and switches. 4) Bathroom: Install a new GFCI protected outlet near the sink. 5) Bathroom: Install a new wall mount light fixture to replace the existing light and cop_~ect to a new switch to be located near the doorway. 1 ~-tc. zoo 121 VVVVVYV vv vvvv nOI\I\I\I\^^ .. ~ ,.. e 6lKitchen: Install (ll additional GFCI pro~ected outlet near the sink. Homeowner ~o designate location. 7) Kitchen: Insure that existing outlets near the sink have proper GFCI protection. BlKitchen/utility area: Install a new circuit and outlet for the washing machine. 9lKitchen: Install a new separate circuit and outlet for a microwave oven. Homeowner to designate lOCation. 10) Kitchen: Install a new separate circuit and (2) additional oUclets. III Kitchen: Install (2) ne~ ceiling light fixtures and connect to a ne~ switch to replace the existing switch near the doorway. 12lUtility area: Install a new 4-foot 4-tube florescent ceiling light fixture to replace the existing light. Connect to a new switch to be located near the kitchen doorway. 13)Living room: Install (2) additional outlets. Homeowner to designate location. 14)Safe-up electric baseboard heaters throughout the house. Insure proper wiring and adequate circuits and breakers. 15)Living room: Install (2) new electric baseboard heaters to replace the existing heaters. Connect to a new separate thermostat switch to replace the existing thermostat. " 16)Master bedroom: Install a new electric baseboard heater to replace the existing heater. Connect to a new separate thermostat switch to replace the eXisting thermostat. 17)Master bedroom: Ins!:all a new 2-foot 2-tube florescent ceiling light in the closet area and connect to a new switch near the closet entry. IB)Master bedroom: Install (2) additional outlets. Homeowner to designate location. 19)Install a new dusk/dawn or motion sensor light at the rear of the house to replace the existing light. Connect to a new switch to be located in the kitchen or util"ity area. 2 j.~. I I I l , coo~ vvvvvvv vv vvvv "'^l'\^^^^" _ ~ e 20}Install.a new dusk/dawn o~ motion sensor light at the . north side of the house. Connect to a new switch to be located near the front entry. 21}SW bedroom: Install a new ceiling light fixture and connect to a new switch to be located near the doorway. 22)SW bedroom: Install a new F/A electric wall heater with a separate thermostat switch near the doorway. ELECTRICAL PE~T AN.D CITY INSPECTION REQUIRED-Contractor to include appropriate fee in bid. Note: Homeowner has experienced extensive problems with circuit overloading, blown light bulbs and fixtures, and outlets and switches not working. renniowl. doe 3 .j.~. Application Number . . . . . 24-00000665 Date 7/09/24 Application pin number . . . 458500 Property Address . . . . . . 419 E 10TH ST ASSESSOR PARCEL NUMBER: 06-30-00-0-2-8865-0000- Application type description ELECTRICAL ONLY Subdivision Name . . . . . . Property Use . . . . . . . . Property Zoning . . . . . . . RS7 RESDNTL SINGLE FAMILY Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc Heat pump ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ RUNNION TONI MARIE BLACK DIAMOND ELECTRICAL CONTR 419 E 10TH ST 502 BLACK DIAMOND RD PORT ANGELES WA 983627925 PORT ANGELES WA 98363 (360) 565-1035 ---------------------------------------------------------------------------- Permit . . . . . . ELECTRICAL ALTER RESIDENTIAL Additional desc . . Permit Fee . . . . 95.10 Plan Check Fee . . .00 Issue Date . . . . 7/09/24 Valuation . . . . 0 Expiration Date . . 1/05/25 Qty Unit Charge Per Extension 1.00 95.1000 ECH EL-R- BRANCH CIR 1-4 95.10 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 95.10 95.10 .00 .00 Plan Check Total .00 .00 .00 .00 Grand Total 95.10 95.10 .00 .00 Public Works and Utilities Department 321 E. 5th Street, Port Angeles, WA 98362 360.417.4735 | www.cityofpa.us | electricalpermits@cityofpa.us EL1-2 SF 1 - 2 SINGLE-FAMILY ELECTRICAL PERMIT APPLICATION Project Address: Project Description: □Single-Family Residential □ Duplex / ARU Building Square footage: OWNER INFORMATION Name: Email: Mailing Address: Phone: ELECTRICAL CONTRACTOR INFORMATION Name: License: Mailing Address: Expiration Date: Email: Phone: PROJECT DETAILS Unit Charge Quantity Total (Quantity x Unit Charge) $190.20 $ $190.20 $ $285.30 $ $380.40 $ $475.50 $ $5.30 $ $95.10 $ $47.55 $ $95.10 $ $95.10 $ $190.20 $ $285.30 $ $380.40 $ $95.10 $ $95.10 $ $190.20 $ $190.20 $ Item Service/Feeder 200 Amp. Service/Feeder 201-400 Amp. Service/Feeder 401-600 Amp. Service/Feeder 601-1000 Amp. Service/Feeder over 1000 Amp. Branch Circuit W/ Service Feeder Branch Circuit W/O Service Feeder Each Additional Branch Circuit Branch Circuits 1-4 Temp. Service/Feeder 200 Amp. Temp. Service/Feeder 201-400 Amp. Temp. Service/Feeder 401-600 Amp. Temp. Service/Feeder 601-1000 Amp. Portal to Portal Hourly Signal Circuit/Limited Energy - 1&2 DU. Manufactured Home Connection Renewable Elec. Energy: 5KVA System or less Thermostat (Note: $5.30 for each additional)$95.10 $ First 1300 Square Feet $190.20 $ Each Additional 500 square feet``$47.55 $ Each Outbuilding / Detached Garage $95.10 $ Each Swimming Pool / Hot Tub $190.20 $ TOTAL $ Owner as defined by RCW.19.28.261: (1) Owner will occupy the structure for two years after this electrical permit is finalized. (2) Owner is required to hire an electrical contractor if above said property is for sale, rent or lease. Permit expires after six months of last inspection. After reading the above statement, I hereby certify that I am the owner of the above named property or a licensed electrical contractor. I am making the electrical installation or alteration in compliance with the electrical laws, N.E.C., RCW. Chapter 19.28, WAC. Chapter 296- 46B, The City of Port Angeles Municipal Code, and Utility Specifications and PAMC 14.05.050 regarding Electrical Permit Applications. Date Print Name Signature (□Owner □Electrical Contractor / Administrator) Pe r m i t # : New Construction Only [Electrical Permit Applications may be submitted to City Hall or epermits@cityofpa.us or faxed to 360.417.4711] ELECTRICAL INSPECTION WIRING REPORT APPROVED NOT APPROVED DITCH ROUGH IN / COVER SERVICE FINAL CORRECTIONS NEEDED: NOTIFY INSPECTOR at (360) 808-2613 WHEN CORRECTIONS ARE COMPLETED WITHIN 15 DAYS DATE PERMIT # INSPECTOR 12/9/2024 24-665 TMC OWNER Contractor Black Diamond Electric ADDRESS 419 E 10th St