Loading...
HomeMy WebLinkAbout1611 E Front St - BuildingApplication Number . . . . . 23-00001108 Date 10/13/23 Application pin number . . . 316956 Property Address . . . . . . 1611 E FRONT ST ASSESSOR PARCEL NUMBER: 06-30-00-1-0-2740-0000- Application type description ELECTRICAL ONLY Subdivision Name . . . . . . Property Use . . . . . . . . Property Zoning . . . . . . . COMMERCIAL ARTERIAL Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc Service repair ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ DHBP ENTERPRISES LLC OHM ELECTRICAL CONTRACTING LLC 10463 SE 14TH STREET 620 S ORCAS ST SUITE 80127 BELLEVUE WA 98004 SEATTLE WA 98108 (206) 973-9184 ---------------------------------------------------------------------------- Permit . . . . . . ELECTRICAL ALTER COMMERCIAL Additional desc . . Permit Fee . . . . 225.00 Plan Check Fee . . .00 Issue Date . . . . 10/13/23 Valuation . . . . 0 Expiration Date . . 4/10/24 Qty Unit Charge Per Extension 1.00 225.0000 ECH EL-COM 401-600 SRV FEEDER 225.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 225.00 225.00 .00 .00 Plan Check Total .00 .00 .00 .00 Grand Total 225.00 225.00 .00 .00 MULTI-FA MILY/ COMMERCIAL ELE CTRICAL PERMIT APPL ICATION Public \Yorks and Utilities Department 321 E. 5th Street, Port Angeles. WA 98362 360.417.4735 I www.cityofpa.us I electricalpermits(s/.cityofpa.us Project Address:--------------------------------------­ Project Description:--------------------------------------â–¡Multi-Family Residential D Commercial I Industrial/ Public Building Square footage: __________ _ OWNER INFORMATION Name: ________________________ Email: ______________ _ Mailing Address: ________________________ Phone: ___________ _ ELECTRICAL CONTRACTOR INFORMATION Name: License: ___________ _ Mailing Address: ________________________ Expiration Date: ________ _ Email: Phone: ___________ _ PROJECT DETAILS llim! Service/Feeder 200 Amp. Service/Feeder 201-400 Amp. Service/Feeder 401-600 Amp. Service/Feeder 601-1000 Amp. Service/Feeder over 1000 Amp. Branch Circuit W/ Service Feeder Branch Circuit W/O Service Feeder Each Additional Branch Circuit Branch Circuits 1-4 Temp. Service/Feeder 200 Amp. Temp. Service/Feeder 201-400 Amp. Temp. Service/Feeder 401-600 Amp. Temp. Service/Feeder 601-1000 Amp. Portal to Portal Hourly Sign / Outline Lighting Signal Circuit/Limited Energy -Multi-Family Signal Circuit/Limited Energy/First 1500 sf -Commercial (Note: $5.00 for each additional 1500 sf) Renewable Elec. Energy: 5KVA System or less Thermostat (Note: $5 for each additional) Unit Charge Quantity $132.00 $160.00 $225.00 $288.00 $410.00 $5.00 $74.00 $5.00 $86.00 $102.00 $121.00 $164.00 $185.00 $96.00 $88.00 $88.00 $96.00 $113.00 $56.00 Total (Quantity x Unit Charge) $ ____ _ $ ____ _$ ____ _$ ____ _ $ ____ _ $ ____ _ $ ____ _ $ ____ _ $ ____ _$ ____ _ $ ____ _ $ ____ _ $ ____ _ $ ____ _ $ ____ _ $ ____ _ $ ____ _ $ ____ _ $ ____ _ $ _____ TOTAL Owner as defined by RCW.19.28.261: (1) Owner will occupy the structure for two years after this electrical permit is finalized. (2) Owner is required to hire an electrical contractor if above said property is for sale, rent or lease. Permit expires after six months of last inspection. After reading the above statement, I hereby certify that I am the owner of the above named property or a licensed electrical contractor. I am making the electrical installation or alteration in compliance with the electrical laws, N.E.C., RCW. Chapter 19.28, WAC. Chapter 296- 46B, The City of Port Angeles Municipal Code, and Utility Specifications and PAMC 14.05.050 regarding Electrical Permit Applications. Date Print Name Signature (0 Owner D Electrical Contractor/ Administrator) [Electrical Permit Applications may be submitted to City Hall or electricalpermits@cityofpa.us] lJ CD ELECTRICAL INSPECTION WIRING REPORT APPROVED NOT APPROVED DITCH ROUGH IN/COVER SERVICE FINAL CORRECTIONS NEEDED: On the line side of the service equipment, use the grounded conductor just as if it were the grounding conductor. Size all your bonding jumpers in accordance with 250.66. Everything has to be bonded to be electrically continuous. NOTIFY INSPECTOR at (360) 808-2613 WHEN CORRECTIONS ARE COMPLETED WITHIN 15 DAYS DATE PERMIT # INSPECTOR 2/16/24 23-1108 TAP OWNER CONTRACTOR Ohm Electric ADDRESS 1611 E Front St ELECTRICAL INSPECTION WIRING REPORT APPROVED NOT APPROVED DITCH ROUGH IN/COVER SERVICE FINAL CORRECTIONS NEEDED: NOTIFY INSPECTOR at (360) 808-2613 WHEN CORRECTIONS ARE COMPLETED WITHIN 15 DAYS DATE PERMIT # INSPECTOR 2/20/24 23-1108 TAP OWNER CONTRACTOR OHM Electric ADDRESS 1611 E Front St ELECTRICAL INSPECTION WIRING REPORT APPROVED NOT APPROVED DITCH ROUGH IN/COVER SERVICE FINAL CORRECTIONS NEEDED: NOTIFY INSPECTOR at (360) 808-2613 WHEN CORRECTIONS ARE COMPLETED WITHIN 15 DAYS DATE PERMIT # INSPECTOR 3/20/24 23-1108 TAP OWNER CONTRACTOR Ohm Electric ADDRESS 1611 E Front St