Loading...
HomeMy WebLinkAbout2703 Porter St - BuildingApplication Number . . . . . 23-00000394 Date 5/04/23 Application pin number . . . 659000 Property Address . . . . . . 2703 PORTER ST ASSESSOR PARCEL NUMBER: 06-30-14-2-1-0120-0000- Application type description ELECTRICAL ONLY Subdivision Name . . . . . . Property Use . . . . . . . . Property Zoning . . . . . . . PUBLIC BUILDINGS & PARKS Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc New service and circuits for cell tower ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ UNITED STATES OF AMERICA TITAN ELECTRIC % NISQUALLY NATL WILD REF 12828 NORTHRUP WAY #205 OLYMPIA WA 98506 BELLEVUE WA 98005 (206) 633-2811 ---------------------------------------------------------------------------- Permit . . . . . . ELECTRICAL NEW COMMERICAL Additional desc . . Permit Fee . . . . 221.00 Plan Check Fee . . .00 Issue Date . . . . 5/04/23 Valuation . . . . 0 Expiration Date . . 10/31/23 Qty Unit Charge Per Extension 1.00 5.0000 ECH EL-BRANCH CIRCUIT W/FEEDER 5.00 1.00 74.0000 ECH EL-COMM BRANCH CIR WO/ S/F 74.00 2.00 5.0000 ECH EL-ECH ADDNT BRANCH CIRCUIT 10.00 1.00 132.0000 ECH EL-COM 0-200 SRV FEEDER 132.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 221.00 221.00 .00 .00 Plan Check Total .00 .00 .00 .00 Grand Total 221.00 221.00 .00 .00 MULTI-FA MILY/ COMMERCIAL ELE CTRICAL PERMIT APPL ICATION Public \Yorks and Utilities Department 321 E. 5th Street, Port Angeles. WA 98362 360.417.4735 I www.cityofpa.us I electricalpermits(s/.cityofpa.us Project Address:--------------------------------------­ Project Description:--------------------------------------□Multi-Family Residential D Commercial I Industrial/ Public Building Square footage: __________ _ OWNER INFORMATION Name: ________________________ Email: ______________ _ Mailing Address: ________________________ Phone: ___________ _ ELECTRICAL CONTRACTOR INFORMATION Name: License: ___________ _ Mailing Address: ________________________ Expiration Date: ________ _ Email: Phone: ___________ _ PROJECT DETAILS llim! Service/Feeder 200 Amp. Service/Feeder 201-400 Amp. Service/Feeder 401-600 Amp. Service/Feeder 601-1000 Amp. Service/Feeder over 1000 Amp. Branch Circuit W/ Service Feeder Branch Circuit W/O Service Feeder Each Additional Branch Circuit Branch Circuits 1-4 Temp. Service/Feeder 200 Amp. Temp. Service/Feeder 201-400 Amp. Temp. Service/Feeder 401-600 Amp. Temp. Service/Feeder 601-1000 Amp. Portal to Portal Hourly Sign / Outline Lighting Signal Circuit/Limited Energy -Multi-Family Signal Circuit/Limited Energy/First 1500 sf -Commercial (Note: $5.00 for each additional 1500 sf) Renewable Elec. Energy: 5KVA System or less Thermostat (Note: $5 for each additional) Unit Charge Quantity $132.00 $160.00 $225.00 $288.00 $410.00 $5.00 $74.00 $5.00 $86.00 $102.00 $121.00 $164.00 $185.00 $96.00 $88.00 $88.00 $96.00 $113.00 $56.00 Total (Quantity x Unit Charge) $ ____ _ $ ____ _$ ____ _$ ____ _ $ ____ _ $ ____ _ $ ____ _ $ ____ _ $ ____ _$ ____ _ $ ____ _ $ ____ _ $ ____ _ $ ____ _ $ ____ _ $ ____ _ $ ____ _ $ ____ _ $ ____ _ $ _____ TOTAL Owner as defined by RCW.19.28.261: (1) Owner will occupy the structure for two years after this electrical permit is finalized. (2) Owner is required to hire an electrical contractor if above said property is for sale, rent or lease. Permit expires after six months of last inspection. After reading the above statement, I hereby certify that I am the owner of the above named property or a licensed electrical contractor. I am making the electrical installation or alteration in compliance with the electrical laws, N.E.C., RCW. Chapter 19.28, WAC. Chapter 296- 46B, The City of Port Angeles Municipal Code, and Utility Specifications and PAMC 14.05.050 regarding Electrical Permit Applications. Date Print Name Signature (0 Owner D Electrical Contractor/ Administrator) [Electrical Permit Applications may be submitted to City Hall or electricalpermits@cityofpa.us] lJ CD PREPARED 4/20/23,12:38:15 PAYMENT DUE CITY OF PORT ANGELES PROGRAM BP820L --------------------------------------------------------------------------- APPLICATION NUMBER:23-00000394 2703 PORTER ST FEE DESCRIPTION AMOUNT DUE --------------------------------------------------------------------------- ELECTRICAL NEW COMMERICAL 221.00 TOTAL DUE 221.00 Please present reciept to the cashier with full payment LOCAL AERIAL MAP PROJECT NAME: PROJECT LOCATION: PROJECT DESCRIPTION: VICINITY MAP DRIVING DIRECTIONS SITE INDEX CONTACT INFORMAT ION SITE INFORMATION PROJECT DESCRIPTION SHEET DESCRIPTION REV DATE DESCRIPTION BY SHEET NUMBER SHEET TITLE TITAN ELECTRIC LEC APPROVAL: POWER APPROVAL: TITLE SHEET T-1 T-1 T-2 A-1 E-1 E-2 TITLE SHEET SCOPE OF WORK OVERALL PROPOSED SITE IMAGE PROPOSED POWER PLAN PROPOSED POWER PHOTOS & DETAILS PRELIMINARY UCR - ANCHOR POWER UPGRADE - 200A - 100A TO 200A SERVICE UPGRADE - (N) Intersect ATS - (N) 200A service meter/main combo - (N) Utility H-Frame for service meter only - (N) tech light, timer, GFCI SE06112A PA BPA PCC 2703 PORTER ST. PORT ANGELES, WA 98362 SE06112A - PA BPA PCC 2703 PORTER ST. PORT ANGELES, WA 98362 1 9.29.22 Utility update AC 2 9.30.33 Ciena relo AC 3 4.20.23 Address change per PA AC REV DATE DESCRIPTION BY SHEET NUMBER SHEET TITLE TITAN ELECTRIC LEC APPROVAL: POWER APPROVAL: T-MOBILE SOW UTILITY SOW T-Mobile SOW -Install (N) H-frame for Meter/main combo -Install (N) 200 amp Meter/Main combo outside of compound (per PUD request) -Install (N) 50 KVA isolation transformer -Install (N) 200 amp Intersect ATS on exterior building wall -Install (N) 4 hour timer, GFCI, LED tech light -Trench approx 135' between existing utility pole and new meter location -Asphalt cut and repair approx 40' across driveway -Install 135' Schedule 80 2.5" PVC conduit (where subject to vehicle traffic, per PUD standards) -Install 5' RMC above grade to meter/main -Install first 10' of Schedule 80' PVC for riser, provide additional 20' for the Utility -Install 170' (3) 3/0 THHN feeders -Trench approx 60' between meter/main to site location -Install 60' Sch40 2.5" PVC conduit between meter/main and ISO xfmr -Install 5' 2.5" RMC above grade from meter/main to PVC -Install 5' 2.5" Liquid Tight from PVC to XFMR -Install 70' (3) 3/0 THHN and #4 THHN gnd -Install approx 5' 2.5" PVC between XFMR and Intersect ATS -Install 5' 2.5" Liquid Tight from XFMR to PVC -Install 5' 2.5" RMC above grade to Intersect ATS -Install 15' (3) 3/0 THHN feeders and #4 THHN gnd -Temp relocate LOCP to Intersect ATS -Install 30' 100 amp temp feed from ATS to SSC -Demo (E) 100 amp service out of BPA building -Trenching to be restored to as good/better condition Utility SOW -Replace/upgrade (E) utility pole -Install (N) Utility transformer -Build new service riser -Provide and Install (N) Meter SCOPE OF WORK T-2 SE06112A PA BPA PCC 2703 PORTER ST. PORT ANGELES, WA 98362 SCALE N.T.S. REV DATE DESCRIPTION BY SHEET NUMBER SHEET TITLE TITAN ELECTRIC LEC APPROVAL: POWER APPROVAL: OVERALL PROPOSED SITE A-1 SE06112A PA BPA PCC 2703 PORTER ST. PORT ANGELES, WA 98362 (N) Trench w/ 2.5" SCH 80 PVC conduit from (E) Utility Pole to (N) Meter/main approx 135' (N) Trench w/ 2.5" PVC conduit from (N) Meter/main to ISO xfmr approx 60' (N) 200 amp Meter/main combo, located outside of fence per PUD Leave 30' 2.5" SCH80 PVC for utility riser REV DATE DESCRIPTION BY SHEET NUMBER SHEET TITLE TITAN ELECTRIC LEC APPROVAL: POWER APPROVAL: PROPOSED POWER SITE PLAN E-1 SE06112A PA BPA PCC 2703 PORTER ST. PORT ANGELES, WA 98362 (N) Trench w/ 2.5" PVC conduit from (N) Meter/main to ISO xfmr approx 60' (N) 2.5" conduit from XFMR to Intersect ATS, approx 10' Mount Ciena to left of ATS (by others) SCALE N.T.S. SCALE N.T.S. SCALE N.T.S. REV DATE DESCRIPTION BY SHEET NUMBER SHEET TITLE TITAN ELECTRIC LEC APPROVAL: POWER APPROVAL: Utility conduit route H-frame location PROPOSED POWER PHOTOS & DETAILS E-2 SE06112A PA BPA PCC 2703 PORTER ST. PORT ANGELES, WA 98362 Utility conduit route (N) Intersect ATS (N) 50kva ISO transformer. Arrow pointing towards front Diplex rack will need to be moved out of the way to provide 36" clearance for panel and XFMR (N) Trench w/ 2.5" PVC conduit from (N) Meter/main to ISO xfmr approx 60' (N) Trench w/ 2.5" PVC conduit from (N) Meter/main to ISO xfmr approx 60' (N) H-frame w/ 200 amp Meter/main combo, located on exterior of fence Relocate Ciena (by others) SCALE N.T.S. SCALE N.T.S. SCALE N.T.S. REV DATE DESCRIPTION BY SHEET NUMBER SHEET TITLE TITAN ELECTRIC LEC APPROVAL: POWER APPROVAL: Utility conduit route PROPOSED POWER PHOTOS & DETAILS E-3 SE06112A PA BPA PCC 2703 PORTER ST. PORT ANGELES, WA 98362 Utility conduit route Utility conduit route (N) Trench w/ 2.5" PVC conduit from (N) Meter/main to ISO xfmr approx 60' (N) H-frame w/ 200 amp Meter/main combo, located on exterior of fence (N) Trench w/ 2.5" SCH 80 PVC conduit from (E) Utility Pole to (N) Meter/main approx 135' (N) Trench w/ 2.5" SCH 80 PVC conduit from (E) Utility Pole to (N) Meter/main approx 135' Saw cut diagonally approx 40' across existing asphalt driveway for (N) utility conduit (N) Trench w/ 2.5" SCH 80 PVC conduit from (E) Utility Pole to (N) Meter/main approx 135' Saw cut diagonally approx 40' across existing asphalt driveway for (N) utility conduit Application Number . . . . . 24-00000186 Date 3/01/24 Application pin number . . . 147758 Property Address . . . . . . 2703 PORTER ST ASSESSOR PARCEL NUMBER: 06-30-14-2-1-0120-0000- Application type description ELECTRICAL ONLY Subdivision Name . . . . . . Property Use . . . . . . . . Property Zoning . . . . . . . PUBLIC BUILDINGS & PARKS Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc Service and circuits ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ UNITED STATES OF AMERICA TITAN ELECTRIC % NISQUALLY NATL WILD REF 12828 NORTHRUP WAY #205 OLYMPIA WA 98506 BELLEVUE WA 98005 (206) 633-2811 ---------------------------------------------------------------------------- Permit . . . . . . ELECTRICAL ALTER COMMERCIAL Additional desc . . Permit Fee . . . . 433.25 Plan Check Fee . . .00 Issue Date . . . . 3/01/24 Valuation . . . . 0 Expiration Date . . 8/28/24 Qty Unit Charge Per Extension 1.00 5.3000 ECH EL-BRANCH CIRCUIT W/FEEDER 5.30 1.00 95.1000 ECH EL-COMM BRANCH CIR WO/ S/F 95.10 2.00 47.5500 ECH EL-ECH ADDNT BRANCH CIRCUIT 95.10 1.00 237.7500 ECH EL-COM 0-200 SRV FEEDER 237.75 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 433.25 433.25 .00 .00 Plan Check Total .00 .00 .00 .00 Grand Total 433.25 433.25 .00 .00 Public Works and Utilities Department 321 E. 5th Street, Port Angeles, WA 98362 360.417.4735 | www.cityofpa.us | electricalpermits@cityofpa.us ELCOM MULTI-FAMILY / COMMERCIAL ELECTRICAL PERMIT APPLICATION Project Address: Project Description: □Multi-Family Residential □ Commercial / Industrial / Public Building Square footage: OWNER INFORMATION Name: Email: Mailing Address: Phone: ELECTRICAL CONTRACTOR INFORMATION Name: License: Mailing Address: Expiration Date: Email: Phone: PROJECT DETAILS Unit Charge Quantity Total (Quantity x Unit Charge) $237.75 $ $237.75 $ $332.85 $ $427.95 $ $523.05 $ $5.60 $ $95.10 $ $47.55 $ $95.10 $ $190.20 $ $237.75 $ $285.30 $ $332.85 $ $95.10 $ $142.65 $ $190.20 $ $190.20 $ $190.20 $ Item Service/Feeder 200 Amp. Service/Feeder 201-400 Amp. Service/Feeder 401-600 Amp. Service/Feeder 601-1000 Amp. Service/Feeder over 1000 Amp. Branch Circuit W/ Service Feeder Branch Circuit W/O Service Feeder Each Additional Branch Circuit Branch Circuits 1-4 Temp. Service/Feeder 200 Amp. Temp. Service/Feeder 201-400 Amp. Temp. Service/Feeder 401-600 Amp. Temp. Service/Feeder 601-1000 Amp. Portal to Portal Hourly Sign / Outline Lighting Signal Circuit/Limited Energy - Multi-Family Signal Circuit/Limited Energy/First 1500 sf - Commercial (Note: $5.60 for each additional 1500 sf) Renewable Elec. Energy: 5KVA System or less Thermostat (Note: $5.60 for each additional)$95.10 $ $ TOTAL Owner as defined by RCW.19.28.261: (1) Owner will occupy the structure for two years after this electrical permit is finalized. (2) Owner is required to hire an electrical contractor if above said property is for sale, rent or lease. Permit expires after six months of last inspection. After reading the above statement, I hereby certify that I am the owner of the above named property or a licensed electrical contractor. I am making the electrical installation or alteration in compliance with the electrical laws, N.E.C., RCW. Chapter 19.28, WAC. Chapter 296- 46B, The City of Port Angeles Municipal Code, and Utility Specifications and PAMC 14.05.050 regarding Electrical Permit Applications. Date Print Name Signature (□Owner □Electrical Contractor / Administrator) Pe r m i t # : [Electrical Permit Applications may be submitted to City Hall or epermits@cityofpa.us or faxed to 360.417.4711] ELECTRICAL INSPECTION WIRING REPORT APPROVED NOT APPROVED DITCH ROUGH IN/COVER SERVICE FINAL CORRECTIONS NEEDED: NOTIFY INSPECTOR at (360) 808-2613 WHEN CORRECTIONS ARE COMPLETED WITHIN 15 DAYS DATE PERMIT # INSPECTOR 3/4/24 24-186 TAP OWNER CONTRACTOR Titan Electric ADDRESS 2703 Porter St ELECTRICAL INSPECTION WIRING REPORT APPROVED NOT APPROVED DITCH ROUGH IN/COVER SERVICE FINAL CORRECTIONS NEEDED: NOTIFY INSPECTOR at (360) 808-2613 WHEN CORRECTIONS ARE COMPLETED WITHIN 15 DAYS DATE PERMIT # INSPECTOR 3/8/24 24-186 TAP OWNER CONTRACTOR Titan Electric ADDRESS 2703 Porter St ELECTRICAL INSPECTION WIRING REPORT APPROVED NOT APPROVED DITCH ROUGH IN/COVER SERVICE FINAL COMMENTS: NOTIFY INSPECTOR at (360) 808-2613 WHEN CORRECTIONS ARE COMPLETED WITHIN 15 DAYS DATE PERMIT # INSPECTOR 12/30/24 24-186 TAP OWNER CONTRACTOR Titan Electric PROJECT ADDRESS 2703 Porter St