HomeMy WebLinkAbout606 S Alder St - BuildingPREPARED 6/20/05 13 15 26 INSPECTION TICKET PAGE 7 CITY OF PORT ANGELES INSPECTOR JAMES L LIERLY DATE 6/20/05 ADDRESS 606 S ALDER ST SUBDIV CONTRACTOR ALL WEATHER HEATING COOLING PHONE (360) 452 9813 OWNER HESS JAMES M PHONE PARCEL 06 30 11 5 5 0870 0000 APPL NUMBER 05 00000446 MECHANICAL APPL PERMIT PERMIT MB 00 MECHANICAL PERMIT REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS ME6 01 6/13/05 JLL 6/14/05 AP ME99 01 6,/20/05 JLL MECHANICAL GAS LINE 06/13/2005 03 37 PM JLIERLY 06/14/2005 08 48 AM JLIERLY MECHANICAL FINAL 06/20/2005 08 48 AM DYASUMUR 452 9813 ALL WEATHER CALL 452 2949 BEFORE INSPECTION (OLDER FOLKS) COMMENTS AND NOTES PREPARED 6/13/05 15 39 51 INSPECTION TICKET PAGE 6 CITY OF PORT ANGELES INSPECTOR JAMES L LIERLY DATE 6/13/05 ADDRESS 606 S ALDER ST SUBDIV CONTRACTOR ALL WEATHER HEATING COOLING PHONE (360) 452 9813 OWNER HESS JAMES M PHONE PARCEL 06 30 11 5 5 0870 0000 APPL NUMBER 05 00000446 MECHANICAL APPL PERMIT PERMIT ME 00 MECHANICAL PERMIT REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS ME6 01 6/13/05 JLL MECHANICAL GAS LINE 06/13/2005 03 37 PM JLIERLY COMMENTS AND NOTES Application Number Application pin number Property Address ASSESSOR PARCEL NUMBER Application type description Subdivision Name Property Use Property Zoning Application valuation Owner HESS JAMES M PO BOX 984 PORT ANGELES yam 99A/9 Permit Additional desc Permit pin number Permit Fee Issue Date Expiration Date Qty Unit Charge Per CITY OF PORT ANGELES DEPARTMENT OF COMMUNITY DEVELOPMENT BUILDING DIVISION 321 EAST 5TH STREET PORT ANGELES, WA 98362 WA 983620170 MECHANICAL PERMIT PROPANE INSERT 50740 57 65 6/08/05 12/05/05 BASE FEE 1 00 10 6500 ECH ME -GAS PIPE Fee summary Charged Paid Permit Fee Total 57 65 57 65 Plan Check Total 00 00 Grand Total 57 65 57 65 Signature of Contractor or Authorized Agent T• \Policies \1102_15 building permit inspection record05.wpd [1/4/2005] 05 00000446 420088 606 S ALDER ST 06 30 11 5 5 0870 0000 MECHANICAL APPL PERMIT RS7 RESDNTL SINGLE FAMILY 3105 Contractor ALL WEATHER HEATING COOLING 302KEMP ST PORT ANGELES WA PORT ANGELES WA 98362 (360) 452 9813 1 TO 5 Credited 00 00 00 Date 6/09/05 Plan Check Fee 00 Valuation 0 Due Extension 47 00 10 65 00 00 00 DC Separate Permits are required for electrical work, SEPA, Shoreline, ESA, utilities, private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days if construction or work is suspended or abandoned for a period of 180 days after the work as commenced or if required inspections have not been requested within 180 days from the last inspection I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. Date Signature of Owner (if owner is builder) Date CALL 417 -4815 FOR BUILDING INSPECTIONS. CALL 417 -4735 FOR ELECTRICAL INSPECTIONS. CALL 417 -4807 FOR PUBLIC WORKS UTILITIES PLEASE PROVIDE A MINIMYJM 24 HOUR NOTICE. IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT IN A CONSPICUOUS LOCATION KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE. INSPECTION TYPE DATE ACCEPTED COMMENTS FOUNDATION: FOOTINGS WALLS FOUNDATION DRAINAGE DOWN SPOUTS PIERS POST HOLES (POLE BLDGS.) PLUMBING UNDERFLOOR /SLAB ROUGH -IN WATER LINE (METER TO BLDG) GAS LINE BACK FLOW WATER AIR SEAL WALLS CEILING FRAMING JOISTS GIRDERS SHEAR WALL/HOLD DOWNS WALLS ROOF CEILING DRYWALL (INTERIOR BRACED PANEL ONLY) T -BAR INSULATION SLAB WALL FLOOR CEILING MECHANICAL HEAT PUMP FURNACE DUCTS GAS LINE WOOD STOVE PELLET CHIMNEY COMMERCIAL HOOD DUCTS MANUFACTURED HOMES FOOTING SLAB BLOCKING HOLD DOWNS SKIRTING PLANNING DEPT SEPARATE PERMIT #'s PARKING/LIGHTING LANDSCAPING RESIDENTIAL ELECTRICAL LIGHT DEPT CONSTRUCTION R.W PW/ ENGINEERING 417 -4807 FIRE 417 -4653 I PLANNING DEPT 417 -4750 1 BUILDING 417 -4815 1 f \Policies \1102_15 building permit inspection record05.wpd [1/4/2005] BUILDING PERMIT INSPECTION RECORD YES 1 NO I 1 1 1 1 1 1 1 1 11 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 I I 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Mean Ft✓KJ 6/90/05 Lilt AP SEPA. ESA. SHORELINE. FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY /USE DATE YES NO COMMERCIAL DATE ACCEPTED YES 1 NO 417 -4735 ELECTRICAL LIGHT DEPT CONSTRUCTION R.W PW ENGINEERING 1 FIRE DEPT 1 PLANNING DEPT 1 BUILDING 1 1 1 1 1 1 1 1 1 JUN -08 -2005 10 18 AM ALL WEATHER H/C Inc Fill out COMPLETELY and In INK. Your application and site plan MUST BE COMPLETE to be accepted for review If you have any questions, call PERMITS (360) 417 -4815 FAX(360)417 -4711 Applicant orAgent:4,LhiactN£_ ,IN-0.1 I a 4.001.I1161 Phone: Uiev `1S2 ‘1111 4 Owner t M ,S4 k 1�l.l�`� 4 55 Phone. C At Address: (O t City WJPT nItiat t Zip OtRtp.2 Architect/Engineer nil Phone: Contractor �E�c(l F ii NCB �,DUUn16 License #11aa Phone. X15•, 9213 Address 3O i 1L_�nnP STQ�e Ae Zip Or 201.1P PROJECT ADDRESS. (pbJp S, At.bE0 ZONING: LEGAL DESCRIPTION Lot: Block: CLALLAM COUNTY PARCEL NUMBER. PLANNING USE ONLY BUILDING PERMIT APPLICATION ESAJWetland(s)• Yes 0 No SEPA Checklist required? Yes 0 No Other 360 452 5177 P 01 Subdivision. FOR OFFICIAL USE ONLY Date Rec. Permit 0._0" 11 4te Date Approved Date Issued Credit Card Holder Name: Billing Address: City' Credit Card Type VISA MC Exp. Date: TYPE OF WORK. SIZE/VALUATION Residential New Constr. Re -roof 0 Stove SF /SF s o Multi family 0 Addition Move Garage SF /SF m Commercial 0 Remodel Demolition Deck SF 5 /SF 0 Repair Sign Other TOTAL VALUATION S 3 lt7W. BRIEF DESCRIPTION OF THE PROJECT. tnt, 4RDantiti�et IKS,�e.T 1.wE 4 .TAX COMMERCIAL/RESIDENTIAL. Occupancy Group: Occupant Load: Construction Type: No. of Stories. Lot Size: Existing Sq. Ft. Proposed Sq. Ft. TOTAL Sq. Ft. Total lot coverage °4 APPROVALS PLAN BLDG. DPWU FIRE OTHER. VALUATION OF CONSTRUCTION In all cases, a valuation amount must be entered by the applicant. This figure will be reviewed and may be revised by the Building Division to comply with current fee schedules. Contact the Permit Coordinator at 417 -4815 for assistance. PLAN CHECK FEE. IF a plan check fee is due it must be submitted at the time the building permit application and construction plans are submitted. All other permit fees are due at the time of permit issuance. EXPIRATION OF PLAN REVIEW If no permit is issued within 180 days of the date of application, the application will expire. The Building Official can extend the time for action by the applicant up to 180 days upon written request by the applicant (see Section R105,3.2 of the International Building/Residential Code, 2003). No application can be extended more than once. I hereby certify that I have read and examined this application and know the same to be true and correct. 1 am authorized to apply for this permit end understand that if is my responsibility to determine whet permits are required ,not the City's, and that 1 must obtain such permits prior to work, TIRVESS\BLDO- forms•brochures \2004- Buildingpetmit,wpd Applicant: Date: L goon r ..- e. . I"^ CITY OF PORT ANGELES LIGHT DEPARTMENT PERMIT NO. ,;;(301 '8/If.,/f"1 f f ELECTRICAL PERMIT DATE Sitel Address: (p 0 Cv 5~ . .4 ( de.-~ D READY FOR D WILL CALL FOR INSPECTION INSPECTION Installed By: [/~ I License Number: Phone: 5......eJ. (. e./ Owner/Business: Phone: OWller/Business Address: Sq. Ft. d Residential Heat KW o Baseboard 0 Furnace/Boiler C Pleatpump 0 Other OJ Commercial/Industrial load Total Connected load (attach breakdown) Total Motor load (attach breakdown) o New Construction o Remodel o Service update/alter/repair o ~erhead ~nderground Voltage "n / z..fi:l> , EY'10 03.0' Service size '{tJD Amps o Temporary o Add/alter circuits o Auxiliary power (list below) o Special equipment (list below) DetailslDescription: ,d-('~ ,/;h; u 5 .J dO KuJ ~ LD~.,( W.S. No. Service Size Capadity: 0 O.K. 0 Not O.K. Comments o Ditch inspection O.K. 6K Er1'fough-in/cover O.K. Cl." t <.." I- ( ;;.ft 0'O.K. to connect service .~ ~ Final O.K. ---tV\\.'. Date Hold for: 0 Easement 0 Letter o Signed up for service/meter o Meter Department notified for installation o Fire Department notified of inspection o Plan Review approved/pending Site Address: A {ol t<.. vV' permitf~iP30Cl ( New Meters Date: Installer: GOt, So .Je-It: u; c ~ Notify the Department of City Light by Street Address and Permit Number when ready for inspection. Work must I]ot be covered or electrically energized before inspection and O.K. for covering or service has been given by the Inspector in Writing on the Wiring Report or the Building Permit. PHONE 457.0411, EXT. 158 or EXT. 224_ .2dc' NO OCCUPANCY OR USE ESTABLISHED UNDER THIS PERMIT ?n ~ - Amount paid GREEN - Top: Inspector, Bottom: City Hall Inspector WHITE + file by address YELLOW - file by number PINK - Top: Eng, Bottom: Customer OLYMPIC "IRINTERS, INC. / . CITY OF PORT ANGELES LIGHT DEPARTMENT PERMIT NO. ;;2~/ 0 c, /lr./tl9 I , ELECTRICAL PERMIT DATE InsI.lled By: 006 .s. E. 'READY FOR INSPECTION License Number: o WILL CALL FOR INSPECTION Phone: Site Address: Owner/Business: Phone: Owner/Business Address: Sq. Ft. o Residential Heat KW [] Baseboard 0 Furnace/Boiler [I] Heatpump 0 Other [] Commercial/Industrial load Total Connected load , (attach breakdown) : Total Motor load : (attach breakdown) o New Construction o Remodel o Service update/alter/repair 'M' Overhead t6 undergrOUn%.h ;gVoitage 7$/7 ,-'f:.JL 10 030 rvice size {.O Amps ,TempOrary o Add/alter circuits o Auxiliary power (list below) o Special equipment (list below) DetailslDescription: . W.S. ' No. Service Capacity: 0 O.K. 0 Not O.K. o Di;tch inspection O.K. o Rough-in/cover O.K. .1/ ~.K. to connect service .eJ Flal O.K. Size Comments Date Hold for: 0 Easement 0 Letter o Signed up for service/meter o Meter Department notified for installation o Fire Department notified of inspection o Plan Review approved/pending Site Address: I I Instaper: Permit/Receipt No. d-d-/O . Notify the Department of City Light by Street Address and Permit Number when ready for inspection. Work must not be covered or eiectrically energized before inspection and O.K. for covering or service has been given by the Inspector in Writing on the Wiring Report or the Building Permit. PHONE 457.0411, EXT.158 or EXT. 224. .-i6f'\1'^-.J NO OCCUPANCY OR USE ESTABLISHED UNDER THIS PERMIT #' It, (l::P Inspector Amount paid WHITEl- file by address YELLOW - file by number PINK - Top: Eng, Bottom: Customer GREEN - Top: Inspector, Bottom: City Hall OLYMPIC PRINTERS. INC. Application Number . . . . . 23-00000389 Date 4/21/23 Application pin number . . . 919482 Property Address . . . . . . 606 S ALDER ST ASSESSOR PARCEL NUMBER: 06-30-11-5-5-0870-0000- Application type description ELECTRICAL ONLY Subdivision Name . . . . . . Property Use . . . . . . . . Property Zoning . . . . . . . RS7 RESDNTL SINGLE FAMILY Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc Battery Addition ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ ERIC R & SUSAN M BJORK BLOSSOM SOLAR LLC 606 S ALDER ST 1706 LOMBARD AVE PORT ANGELES WA 98362 EVERETT WA 98201 (425) 330-4322 ---------------------------------------------------------------------------- Permit . . . . . . ELECTRICAL ALTER RESIDENTIAL Additional desc . . Permit Fee . . . . 63.00 Plan Check Fee . . .00 Issue Date . . . . 4/21/23 Valuation . . . . 0 Expiration Date . . 10/18/23 Qty Unit Charge Per Extension 1.00 63.0000 ECH EL-R- BRANCH CIR WO/ SER FEED 63.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 63.00 63.00 .00 .00 Plan Check Total .00 .00 .00 .00 Grand Total 63.00 63.00 .00 .00 1 - 2 SINGLE-FAMILY ELECTRICAL PERMIT APPLICATION Pub! ic \Yorks and ULili ties Department 32 l E. 5th Street. Port ;\ngeles. WJ\ 98362 300.417.47]5 ! www.cilyofjJa us I electricalpcnnitsr21/cityofpa.us Project Address:--------------------------------------­ Project Description:--------------------------------------□Single-Family Residential D Duplex/ ARU Building Square footage: _______________ _ OWNER JNFORMATtON Name: ________________________ Email: ______________ _ Mailing Address: ________________________ Phone: ___________ _ ELECTRfCAL CONTRACTOR fNFORMATION Name: ___________________________ License: ___________ _ Mailing Address: ________________________ Expiration Date: ________ _ Email: Phone: ___________ _ PROJECT DETAILS Item Unit Charge Qy51ntit3£ :To1s.l (Quantity x Unit Charge) Service/Feeder 200 Amp. $120.00 $ Service/Feeder 201-400 Amp. $146.00 $ Service/Feeder 401-600 Amp. $205.00 $ Service/Feeder 601-1000 Amp. $262.00 $ Service/Feeder over 1000 Amp. $373.00 $ Branch Circuit W/ Service Feeder $5.00 $ Branch Circuit W/O Service Feeder $63.00 $ Each Additional Branch Circuit $5.00 $ Branch Circuits 1-4 $75.00 $ Temp. Service/Feeder 200 Amp. $93.00 $ Temp. Service/Feeder 201-400 Amp. $110.00 $ Temp. Service/Feeder 401-600 Amp. $149.00 $ Temp. Service/Feeder 601-1000 Amp. $168.00 $ Portal to Portal Hourly $96.00 $ Signal CircuiULimited Energy - 1 &2 DU. $64.00 $ Manufactured Home Connection $120.00 $ Ren ewable Elec. Energy: 5KVA System or less $102.00 $ Thermostat (Note: $5 for each additional) $56.00 $ First 1300 Sql;Jare Feet $120.00 $ Each Additional 500 square feet" $40.00 $ Each Outbuilding / Detached Garage $74.00 $ Each Swimming Pool/ Hot Tub $110.00 $ TOTAL $ Owner as defined by RCW.19.28.261: (1) Owner will occupy the structure for two years after this electrical permit is finalized. (2) Owner is required to hire an electrical contractor if above said property is for sale, rent or lease. Permit expires after six months of last inspection. After reading the above statement, I hereby certify that I am the owner of the above named property or a licensed electrical contractor. I am making the electrical installation or alteration in compliance with the electrical laws, N.E.C., RCW. Chapter 19.28, WAC. Chapter 296- 468, The City of Port Angeles Municipal Code, and Utility Specifications and PAMC 14.05.050 regarding Electrical Permit Applications. Date Print Name Signature (0 Owner D Electrical Contractor/ Administrator) [Electrical Permit Applications may be submitted to City Hall or electricalpermits@cityofpa.us] '"'CJ CD PREPARED 4/20/23, 9:25:10 PAYMENT DUE CITY OF PORT ANGELES PROGRAM BP820L --------------------------------------------------------------------------- APPLICATION NUMBER:23-00000389 606 S ALDER ST FEE DESCRIPTION AMOUNT DUE --------------------------------------------------------------------------- ELECTRICAL ALTER RESIDENTIAL 63.00 TOTAL DUE 63.00 Please present reciept to the cashier with full payment DIRECTORY OF PAGES PV-1 PROJECT SUMMARY PV-2 SITE PLAN PV-3.1-2 ELECTRICAL DIAGRAMS PV-4 PV SAFETY LABELS PV-5 ATTACHMENT PLAN PV-6 ATTACHMENT DETAILS PV-7 FIRE SAFETY PLAN AP P E N D I X EQUIPMENT DATASHEETS MOUNTING SYSTEM ENGINEERING LETTER UL 2703 CLASS A FIRE CERTIFICATION UL 2703 GROUNDING AND BONDING CERTIFICATION PROJECT DETAILS PROPERTY OWNER ERIC BJORK PROPERTY ADDRESS 606 S ALDER ST, PORT ANGELES, WA 98362 APN 063011550870 ZONING RESIDENTIAL USE AND OCCUPANCY CLASSIFICATION ONE- OR TWO-FAMILY DWELLING GROUP (GROUP R3) AHJ CITY OF PORT ANGELES UTILITY COMPANY CITY OF PORT ANGELES - (WA) ELECTRICAL CODE 2020 NEC (NFPA 70) FIRE CODE 2018 IFC OTHER BUILDING CODES IBC 2018 IRC 2018 UPC 2018 IMC 2018 CONTRACTOR INFORMATION COMPANY BLOSSOM SOLAR LICENSE NUMBER BLOSSSL823M7 (EC) ADDRESS 1706 LOMBARD AVE, EVERETT, WA 98201-2324 CONTRACTOR SIGNATURE SCOPE OF WORK THIS PROJECT INVOLVES THE INSTALLATION OF A MULTI-MODE PV SYSTEM WITH AN ENERGY STORAGE SYSTEM. PV MODULES WILL BE MOUNTED USING A PREENGINEERED MOUNTING SYSTEM. THE MODULES WILL BE ELECTRICALLY CONNECTED WITH DC TO AC POWER INVERTERS AND INTERCONNECTED TO THE LOCAL UTILITY USING MEANS AND METHODS CONSISTENT WITH THE RULES ENFORCED BY THE LOCAL UTILITY AND PERMITTING JURISDICTION.. A NEW LOADS PANEL WILL BE INSTALLED AS PART OF A PARTIAL HOME BACKUP SYSTEM. A SUBSET OF LOADS WILL BE RELOCATED FROM AN EXISTING LOADS PANEL TO THE NEW LOADS PANEL. THIS DOCUMENT HAS BEEN PREPARED TO DESCRIBE THE DESIGN OF A PROPOSED PV SYSTEM WITH ENOUGH DETAIL TO DEMONSTRATE COMPLIANCE WITH APPLICABLE CODES AND REGULATIONS. THE DOCUMENT SHALL NOT BE RELIED UPON AS A SUBSTITUTE FOR FOLLOWING MANUFACTURER INSTALLATION INSTRUCTIONS. THE SYSTEM SHALL COMPLY WITH ALL MANUFACTURERS INSTALLATION INSTRUCTIONS, AS WELL AS ALL APPLICABLE CODES. NOTHING IN THIS DOCUMENT SHALL BE INTERPRETED IN A WAY THAT OVERRIDES THEM. CONTRACTOR IS RESPONSIBLE FOR VERIFICATION OF ALL DETAILS IN THIS DOCUMENT. SYSTEM DETAILS DESCRIPTION NEW MULTI-MODE PV SYSTEM WITH AC-COUPLED ENERGY STORAGE DC RATING OF SYSTEM 13.30KW AC OUTPUT RATINGS 10.15KW, 42.4A ENERGY STORAGE ENERGY STORAGE SYSTEM CONSISTING OF (2) ENPHASE ENCHARGE-10-1P-NA INVERTER(S)35 X ENPHASE IQ8PLUS-72-2-US MODULE(S)35 X SILFAB SIL-380BK ARRAY WIRING (2) BRANCH OF 11 IQ8PLUS-72-2-US MICROINVERTERS (1) BRANCH OF 13 IQ8PLUS-72-2-US MICROINVERTERS INTERCONNECTION DETAILS POINT OF INTERCONNECTION NEW SUPPLY SIDE AC CONNECTION PER NEC 705.11 UTILITY SERVICE 120/240V 1Φ INSIDE PANELBOARD FUSED EATON DG223NRB DISCONNECT, 2-POLE, 100A, 240VAC SITE DESIGN PARAMETERS ASHRAE EXTREME LOW -7°C (20°F) ASHRAE 2% HIGH 26°C (79°F) CLIMATE DATA SOURCE FAIRCHILD INTERNATIONAL WIND (ASCE 7-16)110 MPH, EXPOSURE CATEGORY B, RISK CATEGORY II GROUND SNOW LOAD 25 PSF BJORK GR I D - T I E D P V S Y S T E M BJ O R K R E S I D E N C E 60 6 S A L D E R S T PO R T A N G E L E S , W A 9 8 3 6 2 PROJECT SUMMARY DOC ID:E10F7A-1 DATE:4/13/23 CREATOR:K.P. REVIEWER:K.P. REVISIONS PV-1 GENERAL NOTES 1 EQUIPMENT LIKELY TO BE WORKED UPON WHILE ENERGIZED SHALL BE INSTALLED IN LOCATIONS THAT SATISFY MIN. WORKING CLEARANCES PER NEC 110.26. 2 24/7 UNESCORTED KEYLESS ACCESS SHALL BE PROVIDED TO ALL CITY OF PORT ANGELES - (WA) EQUIPMENT. 3 CONTRACTOR SHALL USE ONLY COMPONENTS LISTED BY A NATIONALLY RECOGNIZED TESTING LABORATORY FOR THE INTENDED USE. 4 CONTRACTOR IS RESPONSIBLE FOR FURNISHING ALL EQUIPMENT, CABLES, ADDITIONAL CONDUITS, RACEWAYS, AND OTHER ACCESSORIES NECESSARY FOR A COMPLETE AND OPERATIONAL PV SYSTEM. 5 ALL EXPOSED PV ROOFTOP CONDUCTORS NOT UNDER THE ARRAY SHALL BE PROTECTED BY A RACEWAY WITH A LISTED JUNCTION BOX AT BOTH ENDS AND COMPLY WITH NEC 690.31(A). 6 ALL EMT CONDUIT FITTINGS SHALL BE LISTED AS WEATHERPROOF FITTINGS AND INSTALLED TO ENSURE A RAINTIGHT FIT, PER NEC 358.42. (N) PROPOSED ROOF-MOUNTED PV ARRAY. 3/12 (14.0°) SLOPED ROOF, (35) SILFAB SIL-380BK MODULES (BLACK FRAME, BLACK BACKSHEET), 264° AZIMUTH (N) VISIBLE-OPEN TYPE, LOCKABLE, READILY ACCESSIBLE, LABELED PV SYSTEM DISCONNECT LOCATED WITHIN 10 FT OF UTILITY METER (SW1), OUTDOOR (N) RAPID SHUTDOWN INITIATION DEVICE (RSI1), OUTDOOR (N) PROTECTED LOADS PANEL (PAN1), INDOOR (E) MAIN SERVICE PANEL (MSP), INDOOR (N) AC COMBINER (C1), INDOOR (N) ENERGY STORAGE (ESS2), INDOOR (N) MICROGRID INTERCONNECT DEVICE (MID), INDOOR (E) UTILITY METER, OUTDOOR (N) TRANSITION BOX, OUTDOOR, OUTPUT CIRCUIT CONDUCTORS SHALL BE RUN IN EMT CONDUIT OVER ROOF NO CLOSER THAN 7/8″ ABOVE ROOF SURFACE (N) ENERGY STORAGE (ESS1), INDOOR BJORK GR I D - T I E D P V S Y S T E M BJ O R K R E S I D E N C E 60 6 S A L D E R S T PO R T A N G E L E S , W A 9 8 3 6 2 SITE PLAN DOC ID:E10F7A-1 DATE:4/13/23 CREATOR:K.P. REVIEWER:K.P. REVISIONS PV-2 PV MODULE MICRO- INVERTER PM1-35 380W 11 IN BRANCH 11 IN BRANCH 13 IN BRANCH 11 2 1 2 3 4 5 6 7 JUNCTION BOX 4 4 5 JB1 AC COMBINER COMM GATEWAY CB4 20A CB3 20A CB5 20A C1 11 6 8 9 ENPHASE ENCHARGE 10 AC-COUPLED ENERGY STORAGE SYSTEMS 7 ESS1 ESS2 MICROGRID INTERCONNECT DEVICERAPID SHUTDOWN INITIATOR WITHIN 3 FT OF METER 40A40A40A40A PROTECTED LOADS PANEL 10 8 CB2 100A (N) LEVITON 120/240V 1ɸ, 3W 100A BUSBAR (TOP-FED) 100A MAIN BREAKER 3 CB7 15A CB1 40A CB6 60A NN PV DISCONNECT EATON DG223NRB 9 SW1 100A F1-2 100A 10 (E) AC GEC LOADS KWHR LOAD LINE KWHR LOAD LINE UTILITY METER (200A MSP W/150A MCB) 120/240V 1ɸ, 3W 11 12 MODULES REF.QTY.MAKE AND MODEL PMAX PTC ISC IMP VOC VMP TEMP. COEFF. OF VOC FUSE RATING PM1-35 35 SILFAB SIL-380BK 380W 357W 10.50A 9.79A 45.1V 38.9V -0.1258V/°C (-0.28%/°C)20A INVERTERS REF.QTY .MAKE AND MODEL AC VOLTAGE GROUND RATED POWER MAX OUTPUT CURRENT MAX INPUT CURRENT MAX INPUT VOLTAGE CEC WEIGHTED EFFICIENCY I1-35 35 ENPHASE IQ8PLUS-72-2-US 240V NOT SOLIDLY GROUNDED 290W 1.2A 15.0A 60V 97.0% ENERGY STORAGE SYSTEMS REF.QTY .MAKE AND MODEL CHEMISTRY CONTINUOUS POWER CONTINUOUS CURRENT VOLTAGE RANGE ESS1-2 2 ENPHASE ENCHARGE-10-1P-NA LFP 3,840W 15.9A 240 VAC DISCONNECTS REF.QTY .MAKE AND MODEL RATED CURRENT MAX RATED VOLTAGE SW1 1 EATON DG223NRB OR EQUIV.100A 240VAC OCPDS REF.QTY.RATED CURRENT MAX VOLTAGE CB3-5 3 20A 240VAC CB6 1 60A 10KAIC 240VAC CB1 1 40A 10KAIC 240VAC CB2 1 100A 240VAC CB7 1 15A 10KAIC 240VAC F1-2 2 100A 240VAC PASS-THRU BOXES AND COMBINERS REF.QTY .MAKE AND MODEL RATED CURRENT MAX RATED VOLTAGE JB1 1 TRANSITION BOX FOR 3 CIRCUITS 30A 240VAC / 600VDC C1 1 ENPHASE IQ COMBINER 4C W/ IQ GATEWAY FOR PRODUCTION MONITORING 64A 240VAC SYSTEM SUMMARY BRANCH 1 BRANCH 2 BRANCH 3 INVERTERS PER BRANCH 11 11 13 MAX AC CURRENT 13.31A 13.31A 15.73A MAX AC OUTPUT 3,190W 3,190W 3,770W ARRAY STC POWER 13,300W ARRAY PTC POWER 12,506W MAX AC CURRENT 42A MAX AC POWER OUTPUT 10,150W DERATED AC POWER OUTPUT 10,150W RAPID SHUTDOWN DEVICES COMPLIANT WITH REQUIREMENTS AS PER NEC 690.12(B)(2). PV CIRCUIT CONDUCTORS LOCATED OUTSIDE THE ARRAY BOUNDARY (DEFINED AS 3 FEET FROM THE POINT OF PENETRATION INTO A BUILDING OR MORE THAN 3 FEET FROM AN ARRAY) SHALL BE LIMITED TO NOT MORE THAN 30V WITHIN 30 SECONDS OF RAPID SHUTDOWN INITIATION. CONDUCTORS LOCATED INSIDE OF THE ARRAY BOUNDARY SHALL BE LIMITED TO NOT MORE THAN 80 VOLTS WITHIN 30 SECONDS OF SHUTDOWN. 1 ENPHASE SYSTEM MEETS REQUIREMENTS FOR PV HAZARD CONTROL SYSTEM, AS PER NEC 690.12(B)(2).2 THE DC AND AC CONNECTORS OF THE ENPHASE IQ8PLUS-72-2-US AND ARE LISTED TO MEET REQUIREMENTS AS A DISCONNECT MEANS AS ALLOWED BY NEC 690.15(C). MATING CONNECTORS SHALL COMPLY WITH NEC 690.33. 3 THE ENPHASE IQ8PLUS-72-2-US HAS A CLASS II DOUBLE-INSULATED RATING AND DOES NOT REQUIRE GROUNDING ELECTRODE CONDUCTORS (GEC) OR EQUIPMENT GROUNDING CONDUCTORS (EGC). THE RATING INCLUDES GROUND FAULT PROTECTION (GFP). TO SUPPORT GFP, USE ONLY PV MODULES EQUIPPED WITH DC CABLES LABELED PV WIRE OR PV CABLE. 4 MICROINVERTER BRANCH CIRCUIT CONDUCTORS ARE MANUFACTURED ENPHASE Q CABLES LISTED FOR USE IN 20A OR LESS CIRCUITS OF ENPHASE IQ MICROINVERTERS. THEY ARE ROHS, OIL RESISTANT, AND UV RESISTANT. THEY CONTAIN TWO 12 AWG CONDUCTORS OF TYPE THHN/THWN-2 DRY/WET AND CERTIFIED TO UL 3003 AND UL 9703. 5 ALL METAL ENCLOSURES, RACEWAYS, CABLES AND EXPOSED NONCURRENT-CARRYING METAL PARTS OF EQUIPMENT SHALL BE GROUNDED TO EARTH AS REQUIRED BY NEC 250.4(B) AND PART III OF ARTICLE 250 AND DC EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC 690.45. THE GROUNDING ELECTRODE SYSTEM SHALL ADHERE TO NEC 690.47(A) AND NEC 250.169 AND INSTALLED IN COMPLIANCE WITH NEC 250.64. 6 MAX DC VOLTAGE OF PV MODULE IS EXPECTED TO BE 49.1V AT -7°C (-6.6°C - 25°C) X -0.126V/C + 45.1V = 49.1V).7 AC AGGREGATION PANEL BUSBAR AND THE OVERCURRENT PROTECTION PROTECTING THE BUSBAR SHALL BE SIZED IN ACCORDANCE WITH NEC 705.12(B)(3)(3). 8 THE ENPHASE IQ COMBINER 4C CONTAINS A FACTORY-INSTALLED COMMUNICATIONS GATEWAY WITH AN OCPD RATED NO MORE THAN 20A.9 PV SYSTEM DISCONNECT SHALL BE A VISIBLE KNIFE-BLADE TYPE DISCONNECT THAT IS ACCESSIBLE AND LOCKABLE BY THE UTILITY IN ACCORDANCE WITH NEC 690.13(E). THE DISCONNECT SHALL BE LOCATED WITHIN 10 FT OF UTILITY METER AND INSTALLED IN COMPLIANCE WITH NEC 705.20 AND GROUPED AS REQUIRED BY NEC 230.72. 10 POINT-OF-CONNECTION IS ON THE SUPPLY SIDE OF SERVICE DISCONNECT, INSIDE PANELBOARD ENCLOSURE USING UNUSED TERMINALS, TERMINALS THAT ARE SUITABLE FOR DOUBLE LUGGING, OR USING OTHER LOCALLY-APPROVED METHODS AND HARDWARE, IN COMPLIANCE WITH NEC 705.11. THE PANELBOARD SHALL HAVE SUFFICIENT SPACE TO ALLOW FOR ANY TAP HARDWARE AS REQUIRED BY NEC 110.3 AND NEC 312.8(A) 11 RAPID SHUTDOWN INITIATION DEVICE IMO SI16-PEL64R-2-ENP SHALL BE INSTALLED IN ACCORDANCE WITH NEC 690.12(C).12 CONDUCTOR AND CONDUIT SCHEDULE W/ELECTRICAL CALCULATIONS ID TYP CONDUCTOR CONDUIT / CABLE CURRENT-CARRYIN G CONDUCTORS IN CONDUIT/CABLE. OCPD EGC TEMP. CORR. FACTOR FILL FACTOR CONT. CURRENT MAX. CURRENT (125%) BASE AMP.DERATED AMP. TERM. TEMP. RATING AMP. @ TERM. TEMP. RATING LEN.V.D. 1 2 12 AWG THHN/THWN-2 IN ENPHASE Q CABLE, COPPER CABLE 2 20A 6 AWG BARE, COPPER 0.82 (48°C)1.0 13.31A 16.64A 30A 25A 90°C 40A 144.4FT 1.58% 2 1 12 AWG THHN/THWN-2 IN ENPHASE Q CABLE, COPPER CABLE 2 20A 6 AWG BARE, COPPER 0.82 (48°C)1.0 15.73A 19.66A 30A 25A 90°C 40A 85.3FT 2.21% 3 1 3 AWG THWN-2, COPPER 1.25" DIA. PVC-40 3 100A 8 AWG THWN-2, COPPER 1.0 (26°C)1.0 80A 100A 115A 115A 75°C 100A 48IN 0.16% 4 2 12 AWG THWN-2, COPPER 0.75" DIA. EMT 6 20A 12 AWG THWN-2, COPPER 1.0 (26°C)0.8 13.31A 16.64A 30A 24A 90°C 30A 33.8FT 0.37% 5 1 12 AWG THWN-2, COPPER 0.75" DIA. EMT 6 20A 12 AWG THWN-2, COPPER 1.0 (26°C)0.8 15.73A 19.66A 30A 24A 90°C 30A 16.9FT 0.44% 6 1 6 AWG THWN-2, COPPER 0.75" DIA. EMT 4 60A 10 AWG THWN-2, COPPER 1.0 (26°C)0.8 42.35A 52.94A 75A 60A 90°C 75A 8.2FT 0.14% 7 2 8 AWG THWN-2, COPPER 0.75" DIA. EMT 2 40A 10 AWG THWN-2, COPPER 1.0 (26°C)1.0 31.8A 39.75A 55A 55A 75°C 50A 8FT 0.08% 8 1 3 AWG THWN-2, COPPER 1.25" DIA. PVC-40 3 100A 8 AWG THWN-2, COPPER 1.0 (26°C)1.0 74.15A (DERS) 80A (LOADS) 100A 115A 115A 75°C 100A 79IN 0.13% 9 1 3 AWG THWN-2, COPPER 1.25" DIA. PVC-40 3 100A N/A 1.0 (26°C)1.0 74.15A (DERS) 80A (LOADS) 100A 115A 115A 75°C 100A 48IN 0.08% 10 1 12 AWG THWN-2, COPPER 0.75" DIA. EMT 4 N/A 12 AWG THWN-2, COPPER 1.0 (26°C)0.8 16A 20A 30A 24A 75°C 25A 9.9FT 0.05% 11 1 12 AWG THWN-2, COPPER 0.75" DIA. EMT 5 15A 12 AWG THWN-2, COPPER 1.0 (26°C)0.8 12A 15A 30A 24A 75°C 25A 8.2FT 0.2%REVISIONS PROJECT ID: CREATED BY: REVIEWER: DATE: SCALE: GR I D - T I E D P V S Y S T E M PO R T A N G E L E S , W A 9 8 3 6 2 60 6 S A L D E R S T PV-3.1 Bjork 4/13/23 K.P. K.P. E10F7A-1 SINGLE-LINE DIAGRAM BJ O R K R E S I D E N C E 1 PV-3.1 SINGLE-LINE DIAGRAM NTS GROUNDING NOTES 1 ALL EQUIPMENT SHALL BE PROPERLY GROUNDED PER THE REQUIREMENTS OF NEC ARTICLES 250 & 690 2 PV MODULES SHALL BE GROUNDED TO MOUNTING RAILS USING MODULE LUGS OR RACKING INTEGRATED GROUNDING CLAMPS AS ALLOWED BY LOCAL JURISDICTION. ALL OTHER EXPOSED METAL PARTS SHALL BE GROUNDED USING UL-LISTED LAY-IN LUGS. 3 INSTALLER SHALL CONFIRM THAT MOUNTING SYSTEM HAS BEEN EVALUATED FOR COMPLIANCE WITH UL 2703 "GROUNDING AND BONDING" WHEN USED WITH PROPOSED PV MODULE. 4 IF THE EXISTING MAIN SERVICE PANEL DOES NOT HAVE A VERIFIABLE GROUNDING ELECTRODE, IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE. 5 AC SYSTEM GROUNDING ELECTRODE CONDUCTOR (GEC) SHALL BE A MINIMUM SIZE #8AWG WHEN INSULATED, #6AWG IF BARE WIRE. 6 EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC ARTICLE 690.45, AND BE A MINIMUM OF #10AWG WHEN NOT EXPOSED TO DAMAGE, AND #6AWG SHALL BE USED WHEN EXPOSED TO DAMAGE 7 GROUNDING AND BONDING CONDUCTORS, IF INSULATED, SHALL BE COLOR CODED GREEN, OR MARKED GREEN IF #4AWG OR LARGER GENERAL ELECTRICAL NOTES 1 UTILITY HAS 24-HR UNRESTRICTED ACCESS TO ALL PHOTOVOLTAIC SYSTEM COMPONENTS LOCATED AT THE SERVICE ENTRANCE. 2 CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT PER NEC ARTICLE 300.6 (C) (1) AND ARTICLE 310.10 (D). 3 CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE FOR USE IN WET LOCATIONS PER NEC ARTICLE 310.10 (C). EXPIRES: 06/05/2023 04/19/2023 Firm License Number: 2202 ELECTRICAL ONLY VSE Project Number: U2869.0008.231 PV MODULE MICROINVERTER 11 IN BRANCH 11 IN BRANCH 13 IN BRANCH PM1-35 380W 2 1 1 1 2 3 4 5 6 7 JUNCTION BOX JB1 5 4 4 COMM GATEWAY AC COMBINER 6 11 CB3 20A CB4 20A CB5 20A 8 9 ENPHASE ENCHARGE 10 AC-COUPLED ENERGY STORAGE SYSTEMS 7 ESS1 ESS2 40A PROTECTED LOADS PANEL LOADS RAPID SHUTDOWN INITIATOR WITHIN 3 FT OF METER MICROGRID INTERCONNECT DEVICE CB6 60A CB1 40ACB7 15A CB2 100A 3 (N) LEVITON 120/240V 1ɸ, 3W 100A BUSBAR (TOP-FED) 100A MAIN BREAKER 10 8 F1-2 100A SW1 100A 9 EATON DG223NRB PV DISCONNECT 10 (E) AC GEC UTILITY METER LINE LOAD LINE LOAD (E) GROUNDING ELECTRODE (N) AC GEC LOADS MCB LOADS MCB (200A MSP W/150A MCB) 120/240V 1ɸ, 3W 11 12 MODULES REF.QTY.MAKE AND MODEL PMAX PTC ISC IMP VOC VMP TEMP. COEFF. OF VOC FUSE RATING PM1-35 35 SILFAB SIL-380BK 380W 357W 10.50A 9.79A 45.1V 38.9V -0.1258V/°C (-0.28%/°C)20A INVERTERS REF.QTY .MAKE AND MODEL AC VOLTAGE GROUND RATED POWER MAX OUTPUT CURRENT MAX INPUT CURRENT MAX INPUT VOLTAGE CEC WEIGHTED EFFICIENCY I1-35 35 ENPHASE IQ8PLUS-72-2-US 240V NOT SOLIDLY GROUNDED 290W 1.2A 15.0A 60V 97.0% ENERGY STORAGE SYSTEMS REF.QTY .MAKE AND MODEL CHEMISTRY CONTINUOUS POWER CONTINUOUS CURRENT VOLTAGE RANGE ESS1-2 2 ENPHASE ENCHARGE-10-1P-NA LFP 3,840W 15.9A 240 VAC DISCONNECTS REF.QTY .MAKE AND MODEL RATED CURRENT MAX RATED VOLTAGE SW1 1 EATON DG223NRB OR EQUIV.100A 240VAC OCPDS REF.QTY.RATED CURRENT MAX VOLTAGE CB3-5 3 20A 240VAC CB6 1 60A 10KAIC 240VAC CB1 1 40A 10KAIC 240VAC CB2 1 100A 240VAC CB7 1 15A 10KAIC 240VAC F1-2 2 100A 240VAC PASS-THRU BOXES AND COMBINERS REF.QTY .MAKE AND MODEL RATED CURRENT MAX RATED VOLTAGE JB1 1 TRANSITION BOX FOR 3 CIRCUITS 30A 240VAC / 600VDC C1 1 ENPHASE IQ COMBINER 4C W/ IQ GATEWAY FOR PRODUCTION MONITORING 64A 240VAC SYSTEM SUMMARY BRANCH 1 BRANCH 2 BRANCH 3 INVERTERS PER BRANCH 11 11 13 MAX AC CURRENT 13.31A 13.31A 15.73A MAX AC OUTPUT 3,190W 3,190W 3,770W ARRAY STC POWER 13,300W ARRAY PTC POWER 12,506W MAX AC CURRENT 42A MAX AC POWER OUTPUT 10,150W DERATED AC POWER OUTPUT 10,150W RAPID SHUTDOWN DEVICES COMPLIANT WITH REQUIREMENTS AS PER NEC 690.12(B)(2). PV CIRCUIT CONDUCTORS LOCATED OUTSIDE THE ARRAY BOUNDARY (DEFINED AS 3 FEET FROM THE POINT OF PENETRATION INTO A BUILDING OR MORE THAN 3 FEET FROM AN ARRAY) SHALL BE LIMITED TO NOT MORE THAN 30V WITHIN 30 SECONDS OF RAPID SHUTDOWN INITIATION. CONDUCTORS LOCATED INSIDE OF THE ARRAY BOUNDARY SHALL BE LIMITED TO NOT MORE THAN 80 VOLTS WITHIN 30 SECONDS OF SHUTDOWN. 1 ENPHASE SYSTEM MEETS REQUIREMENTS FOR PV HAZARD CONTROL SYSTEM, AS PER NEC 690.12(B)(2).2 THE DC AND AC CONNECTORS OF THE ENPHASE IQ8PLUS-72-2-US AND ARE LISTED TO MEET REQUIREMENTS AS A DISCONNECT MEANS AS ALLOWED BY NEC 690.15(C). MATING CONNECTORS SHALL COMPLY WITH NEC 690.33. 3 THE ENPHASE IQ8PLUS-72-2-US HAS A CLASS II DOUBLE-INSULATED RATING AND DOES NOT REQUIRE GROUNDING ELECTRODE CONDUCTORS (GEC) OR EQUIPMENT GROUNDING CONDUCTORS (EGC). THE RATING INCLUDES GROUND FAULT PROTECTION (GFP). TO SUPPORT GFP, USE ONLY PV MODULES EQUIPPED WITH DC CABLES LABELED PV WIRE OR PV CABLE. 4 MICROINVERTER BRANCH CIRCUIT CONDUCTORS ARE MANUFACTURED ENPHASE Q CABLES LISTED FOR USE IN 20A OR LESS CIRCUITS OF ENPHASE IQ MICROINVERTERS. THEY ARE ROHS, OIL RESISTANT, AND UV RESISTANT. THEY CONTAIN TWO 12 AWG CONDUCTORS OF TYPE THHN/THWN-2 DRY/WET AND CERTIFIED TO UL 3003 AND UL 9703. 5 ALL METAL ENCLOSURES, RACEWAYS, CABLES AND EXPOSED NONCURRENT-CARRYING METAL PARTS OF EQUIPMENT SHALL BE GROUNDED TO EARTH AS REQUIRED BY NEC 250.4(B) AND PART III OF ARTICLE 250 AND DC EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC 690.45. THE GROUNDING ELECTRODE SYSTEM SHALL ADHERE TO NEC 690.47(A) AND NEC 250.169 AND INSTALLED IN COMPLIANCE WITH NEC 250.64. 6 MAX DC VOLTAGE OF PV MODULE IS EXPECTED TO BE 49.1V AT -7°C (-6.6°C - 25°C) X -0.126V/C + 45.1V = 49.1V).7 AC AGGREGATION PANEL BUSBAR AND THE OVERCURRENT PROTECTION PROTECTING THE BUSBAR SHALL BE SIZED IN ACCORDANCE WITH NEC 705.12(B)(3)(3). 8 THE ENPHASE IQ COMBINER 4C CONTAINS A FACTORY-INSTALLED COMMUNICATIONS GATEWAY WITH AN OCPD RATED NO MORE THAN 20A.9 PV SYSTEM DISCONNECT SHALL BE A VISIBLE KNIFE-BLADE TYPE DISCONNECT THAT IS ACCESSIBLE AND LOCKABLE BY THE UTILITY IN ACCORDANCE WITH NEC 690.13(E). THE DISCONNECT SHALL BE LOCATED WITHIN 10 FT OF UTILITY METER AND INSTALLED IN COMPLIANCE WITH NEC 705.20 AND GROUPED AS REQUIRED BY NEC 230.72. 10 POINT-OF-CONNECTION IS ON THE SUPPLY SIDE OF SERVICE DISCONNECT, INSIDE PANELBOARD ENCLOSURE USING UNUSED TERMINALS, TERMINALS THAT ARE SUITABLE FOR DOUBLE LUGGING, OR USING OTHER LOCALLY-APPROVED METHODS AND HARDWARE, IN COMPLIANCE WITH NEC 705.11. THE PANELBOARD SHALL HAVE SUFFICIENT SPACE TO ALLOW FOR ANY TAP HARDWARE AS REQUIRED BY NEC 110.3 AND NEC 312.8(A) 11 RAPID SHUTDOWN INITIATION DEVICE IMO SI16-PEL64R-2-ENP SHALL BE INSTALLED IN ACCORDANCE WITH NEC 690.12(C).12 CONDUCTOR AND CONDUIT SCHEDULE W/ELECTRICAL CALCULATIONS ID TYP CONDUCTOR CONDUIT / CABLE CURRENT-CARRYIN G CONDUCTORS IN CONDUIT/CABLE. OCPD EGC TEMP. CORR. FACTOR FILL FACTOR CONT. CURRENT MAX. CURRENT (125%) BASE AMP.DERATED AMP. TERM. TEMP. RATING AMP. @ TERM. TEMP. RATING LEN.V.D. 1 2 12 AWG THHN/THWN-2 IN ENPHASE Q CABLE, COPPER CABLE 2 20A 6 AWG BARE, COPPER 0.82 (48°C)1.0 13.31A 16.64A 30A 25A 90°C 40A 144.4FT 1.58% 2 1 12 AWG THHN/THWN-2 IN ENPHASE Q CABLE, COPPER CABLE 2 20A 6 AWG BARE, COPPER 0.82 (48°C)1.0 15.73A 19.66A 30A 25A 90°C 40A 85.3FT 2.21% 3 1 3 AWG THWN-2, COPPER 1.25" DIA. PVC-40 3 100A 8 AWG THWN-2, COPPER 1.0 (26°C)1.0 80A 100A 115A 115A 75°C 100A 48IN 0.16% 4 2 12 AWG THWN-2, COPPER 0.75" DIA. EMT 6 20A 12 AWG THWN-2, COPPER 1.0 (26°C)0.8 13.31A 16.64A 30A 24A 90°C 30A 33.8FT 0.37% 5 1 12 AWG THWN-2, COPPER 0.75" DIA. EMT 6 20A 12 AWG THWN-2, COPPER 1.0 (26°C)0.8 15.73A 19.66A 30A 24A 90°C 30A 16.9FT 0.44% 6 1 6 AWG THWN-2, COPPER 0.75" DIA. EMT 4 60A 10 AWG THWN-2, COPPER 1.0 (26°C)0.8 42.35A 52.94A 75A 60A 90°C 75A 8.2FT 0.14% 7 2 8 AWG THWN-2, COPPER 0.75" DIA. EMT 2 40A 10 AWG THWN-2, COPPER 1.0 (26°C)1.0 31.8A 39.75A 55A 55A 75°C 50A 8FT 0.08% 8 1 3 AWG THWN-2, COPPER 1.25" DIA. PVC-40 3 100A 8 AWG THWN-2, COPPER 1.0 (26°C)1.0 74.15A (DERS) 80A (LOADS) 100A 115A 115A 75°C 100A 79IN 0.13% 9 1 3 AWG THWN-2, COPPER 1.25" DIA. PVC-40 3 100A N/A 1.0 (26°C)1.0 74.15A (DERS) 80A (LOADS) 100A 115A 115A 75°C 100A 48IN 0.08% 10 1 12 AWG THWN-2, COPPER 0.75" DIA. EMT 4 N/A 12 AWG THWN-2, COPPER 1.0 (26°C)0.8 16A 20A 30A 24A 75°C 25A 9.9FT 0.05% 11 1 12 AWG THWN-2, COPPER 0.75" DIA. EMT 5 15A 12 AWG THWN-2, COPPER 1.0 (26°C)0.8 12A 15A 30A 24A 75°C 25A 8.2FT 0.2%REVISIONS PROJECT ID: CREATED BY: REVIEWER: DATE: SCALE: GR I D - T I E D P V S Y S T E M PO R T A N G E L E S , W A 9 8 3 6 2 60 6 S A L D E R S T PV-3.2 Bjork 4/13/23 K.P. K.P. E10F7A-1 THREE-LINE DIAGRAM BJ O R K R E S I D E N C E 1 PV-3.2 THREE-LINE DIAGRAM NTS GROUNDING NOTES 1 ALL EQUIPMENT SHALL BE PROPERLY GROUNDED PER THE REQUIREMENTS OF NEC ARTICLES 250 & 690 2 PV MODULES SHALL BE GROUNDED TO MOUNTING RAILS USING MODULE LUGS OR RACKING INTEGRATED GROUNDING CLAMPS AS ALLOWED BY LOCAL JURISDICTION. ALL OTHER EXPOSED METAL PARTS SHALL BE GROUNDED USING UL-LISTED LAY-IN LUGS. 3 INSTALLER SHALL CONFIRM THAT MOUNTING SYSTEM HAS BEEN EVALUATED FOR COMPLIANCE WITH UL 2703 "GROUNDING AND BONDING" WHEN USED WITH PROPOSED PV MODULE. 4 IF THE EXISTING MAIN SERVICE PANEL DOES NOT HAVE A VERIFIABLE GROUNDING ELECTRODE, IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE. 5 AC SYSTEM GROUNDING ELECTRODE CONDUCTOR (GEC) SHALL BE A MINIMUM SIZE #8AWG WHEN INSULATED, #6AWG IF BARE WIRE. 6 EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC ARTICLE 690.45, AND BE A MINIMUM OF #10AWG WHEN NOT EXPOSED TO DAMAGE, AND #6AWG SHALL BE USED WHEN EXPOSED TO DAMAGE 7 GROUNDING AND BONDING CONDUCTORS, IF INSULATED, SHALL BE COLOR CODED GREEN, OR MARKED GREEN IF #4AWG OR LARGER GENERAL ELECTRICAL NOTES 1 UTILITY HAS 24-HR UNRESTRICTED ACCESS TO ALL PHOTOVOLTAIC SYSTEM COMPONENTS LOCATED AT THE SERVICE ENTRANCE. 2 CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT PER NEC ARTICLE 300.6 (C) (1) AND ARTICLE 310.10 (D). 3 CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE FOR USE IN WET LOCATIONS PER NEC ARTICLE 310.10 (C). EXPIRES: 06/05/2023 04/19/2023 Firm License Number: 2202 ELECTRICAL ONLY VSE Project Number: U2869.0008.231 AC COMBINER RAPID SHUTDOWN INITIATION DEVICE SW1 - DISCONNECT (EATON DG223NRB) ESS1-2 - ENERGY STORAGE (ENPHASE ENCHARGE-10-1P-NA) CB1,6 IN MICROGRID INTERCONNECT DEVICE UTILITY METER MAIN SERVICE PANEL SEE NOTE NO. 4 (SW1, MSP) SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE 'OFF' POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY. NEC 690.56(C)(1) AND IFC 1204.5.1 AC COMBINER PANEL (C1) ! WARNING ! THIS EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRENT DEVICES, EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE SHALL NOT EXCEED AMPACITY OF BUSBAR. NEC 705.12(B)(3)(3) POINT-OF-INTERCONNECTION OR AT MAIN SERVICE DISCONNECT (MSP, UM) ! CAUTION: MULTIPLE SOURCES OF POWER ! POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH SAFETY DISCONNECTS AS SHOWN INSTALLED BY BLOSSOM SOLAR NEC 690.56(B), NEC 705.10, AND NEC 706.21 SEE NOTE NO. 5 (RSI1) RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM NEC 690.56(C)(3) AND IFC 1204.5.3 EACH DISCONNECTING MEANS FOR PHOTOVOLTAIC EQUIPMENT (SW1) ! WARNING ! ELECTRIC SHOCK HAZARD. TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. NEC 690.13(B) PV SYSTEM DISCONNECT (SW1, CB1 IN MID, CB6 IN MID) PV SYSTEM DISCONNECT NEC 690.13(B) ANY AC ELECTRICAL PANEL THAT IS FED BY BOTH THE UTILITY AND THE PHOTOVOLTAIC SYSTEM (SW1, MSP) ! CAUTION ! MULTIPLE SOURCES OF POWER NEC 705.10 AC DISCONNECT (SW1) MAXIMUM AC OPERATING CURRENT: 74.2A MAXIMUM AC OPERATING VOLTAGE: 240V NEC 690.54 ENERGY STORAGE SYSTEM DISCONNECT (ESS1, ESS2) ENERGY STORAGE SYSTEM DISCONNECT MAXIMUM ESS AC VOLTAGE: 240V MAXIMUM ESS DC VOLTAGE: N/A NEC 706.15(C) LABELING NOTES 1 ALL PLAQUES AND SIGNAGE REQUIRED BY 2020 NEC AND 2018 IFC WILL BE INSTALLED AS REQUIRED. 2 LABELS, WARNING(S) AND MARKING SHALL COMPLY WITH ANSI Z535.4, WHICH REQUIRES THAT DANGER, WARNING, AND CAUTION SIGNS USED THE STANDARD HEADER COLORS, HEADER TEXT, AND SAFETY ALERT SYMBOL ON EACH LABEL. THE ANSI STANDARD REQUIRES A HEADING THAT IS AT LEAST 50% TALLER THAN THE BODY TEXT, IN ACCORDANCE WITH NEC 110.21(B). 3 A PERMANENT PLAQUE OR DIRECTORY SHALL BE INSTALLED PROVIDING THE LOCATION OF THE SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM DISCONNECTING MEANS IF NOT IN THE SAME LOCATION IN ACCORDANCE WITH NEC 690.56(B). 4 LABEL(S) WITH MARKING, "TURN RAPID SHUTDOWN SWITCH TO THE 'OFF' POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY," SHALL BE LOCATED WITHIN 3 FT OF SERVICE DISCONNECTING MEANS THE TITLE SHALL UTILIZE CAPITALIZED LETTERS WITH A MINIMUM HEIGHT OF 3/8″ IN BLACK ON A YELLOW BACKGROUND, AND REMAINING TEXT SHALL BE CAPITALIZED WITH A MINIMUM HEIGHT OF 3/16″ IN BLACK ON WHITE BACKGROUND 5 LABEL(S) WITH MARKING, "RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM," SHALL BE LOCATED WITHIN 3 FT OF RAPID SHUTDOWN SWITCH THE LABEL SHALL HAVE 3/8″ TALL LETTERS AND BE REFLECTIVE WITH WHITE TEXT ON A RED BACKGROUND BJORK GR I D - T I E D P V S Y S T E M BJ O R K R E S I D E N C E 60 6 S A L D E R S T PO R T A N G E L E S , W A 9 8 3 6 2 SAFETY LABELS DOC ID:E10F7A-1 DATE:4/13/23 CREATOR:K.P. REVIEWER:K.P. REVISIONS PV-4 EXPIRES: 06/05/2023 04/19/2023 Firm License Number: 2202 ELECTRICAL ONLY VSE Project Number: U2869.0008.231 STRUCTURAL DESIGN PARAMETERS ELEVATION 282 FT SEISMIC 1.299 SDS WIND (ASCE 7-16)110 MPH, EXPOSURE CATEGORY B, RISK CATEGORY II GROUND SNOW LOAD 25 PSF ROOF PROPERTIES ROOF MATERIAL COMPOSITION SHINGLE (1 LAYER) SLOPE 3/12 (14.0°) MEAN ROOF HEIGHT 12.9FT ROOF DECKING 15/32" OSB CONSTRUCTION TRUSSES (2X4 TOP-CHORD), 24IN OC MODULE MECHANICAL PROPERTIES MODEL SILFAB SIL-380BK DIMENSIONS (AREA)70.7IN X 39.0IN X 1.5IN (19.1 SQ FT) WEIGHT 41.9 LBS MOUNTING SYSTEM PROPERTIES RAIL MODEL IRONRIDGE XR100 ANCHOR MODEL IRONRIDGE FV-01-B1 (FLASHED), 3.38IN AIR GAP FASTENING METHOD 2.5 INCH EMBEDMENT INTO TRUSSES WITH (1) 5/16IN DIA. FASTENER GROUNDING AND BONDING INTEGRAL GROUNDING CERTIFIED TO UL 2703 REQUIREMENTS DEAD LOAD CALCULATIONS LOAD QTY LBS TOTAL LBS MODULES 35 41.9 1466.1 MICROINVERTERS 35 2.4 83.3 LINEAR FEET OF RAIL 232 FT 0.7 157.9 ANCHORS 49 0.6 29.4 MISC. HARDWARE 13.1 13.1 TOTAL ARRAY WEIGHT 1749.7 LBS AREA NAME QTY SQFT TOTAL SQFT MODULES 35 19.1 668.5 POINT LOAD (1749.7 LBS / 49 ATTACHMENTS)35.7 LBS DIST. LOAD (1749.7 LBS / 668.5 SQFT)2.62 PSF NOTES 1 TRUSS LOCATIONS ARE APPROXIMATE. CONTRACTOR MAY NEED TO MAKE MINOR ADJUSTMENTS TO ANCHOR LOCATIONS. IN NO CASE SHALL THE ANCHOR SPACING EXCEED "MAX. ANCHOR SPACING" ANCHOR PLACEMENT PARAMETERS (ASCE 7-16) WIND PRESSURE ZONE MODULE WIND EXPOSURE MAX. ALLOWABLE RAIL SPAN MAX. ANCHOR SPACING MAX. ALLOWABLE CANTILEVER ZONES 1, 2E, 2N, 2R, 3E NORMAL 90.0IN 72.0IN 36.0IN DISTANCE α IS EQUAL TO 10% OF THE BUILDING'S LEAST HORIZONTAL DIMENSION ("LHD") OR 40% OF THE MEAN ROOF HEIGHT, WHICHEVER IS SMALLER, BUT NOT LESS THAN 4% OF THE LHD OR 3 FT. THESE SETBACKS ARE APPLIED TO THE BUILDING FOOTPRINT AND PROJECTED TO THE ROOF PLANES IN ACCORDANCE WITH GUIDANCE PROVIDED BY ASCE 7-16 FIGURES 30.3-2B–I. α = MAX(MIN(0.4 * MEAN ROOF HEIGHT, 0.1 * LHD), 0.04 * LHD, 3 FT) 4.7 FT = MAX(MIN(0.4 * 12.9 FT, 0.1 * 47.1 FT), 0.04 * 47.1 FT, 3 FT) BJORK GR I D - T I E D P V S Y S T E M BJ O R K R E S I D E N C E 60 6 S A L D E R S T PO R T A N G E L E S , W A 9 8 3 6 2 ATTACHMENT PLAN DOC ID:E10F7A-1 DATE:4/13/23 CREATOR:K.P. REVIEWER:K.P. REVISIONS PV-5 BJORK GR I D - T I E D P V S Y S T E M BJ O R K R E S I D E N C E 60 6 S A L D E R S T PO R T A N G E L E S , W A 9 8 3 6 2 ATTACHMENT DETAILS DOC ID:E10F7A-1 DATE:4/13/23 CREATOR:K.P. REVIEWER:K.P. REVISIONS PV-6 GENERAL NOTES 1 AT LEAST TWO 3′-WIDE PATHWAYS ON SEPARATE ROOF PLANES, FROM LOWEST ROOF EDGE TO RIDGE, SHALL BE PROVIDED ON ALL BUILDINGS, WITH AT LEAST ONE PATHWAY ON THE STREET OR DRIVEWAY SIDE OF THE ROOF. FOR EACH ROOF PLANE WITH A PV ARRAY, AT LEAST ONE SUCH PATHWAY FROM LOWEST ROOF EDGE TO RIDGE SHALL BE PROVIDED ON THE SAME ROOF PLANE, OR ON AN ADJACENT ROOF PLANE, OR STRADDLING THE SAME AND ADJACENT ROOF PLANES. (IFC 1204.2.1.1) 2 FOR PV ARRAYS OCCUPYING 33% OR LESS OF THE PLAN VIEW TOTAL ROOF AREA, A MIN. 18″-WIDE SETBACK IS REQUIRED ON BOTH SIDES OF A HORIZONTAL RIDGE. (IFC 1204.2.1.2) 3 PV MODULES SHALL NOT BE PLACED BELOW AN EMERGENCY ESCAPE/RESCUE OPENING. A 3′-WIDE PATHWAY SHALL BE PROVIDED TO SUCH AN OPENING. (IFC 1204.2.2) 4 ROOF FACES WITH NO PV ARE DESIGNATED FOR FIRE VENTILATION AND ACCESS 1.5′ WIDE SMOKE-VENTILATION SETBACK, PER IFC 1204.2.1.2 PV MODULES INSTALLED ON ROOF WITH IRONRIDGE ROOF MOUNTING SYSTEM. THE MOUNTING SYSTEM IS UL 2703 CLASS A FIRE RATED ON THIS STEEP-SLOPED ROOF WHEN INSTALLED WITH TYPE 1 OR 2 MODULES. THE SILFAB SIL-380BK IS UL 1703 CERTIFIED TYPE 1. ROOF ACCESS POINT 3.0′ WIDE FIRE ACCESS PATHWAY, PER IFC 1204.2.1.1 BUILDING IS 1-STORY, GROUP R3 TOTAL PLAN VIEW ARRAY AREA IS 649.5 SQ.FT, WHICH REPRESENTS 20.1% OF TOTAL PLAN VIEW ROOF AREA (3225.5 SQ.FT) THIS SYSTEM UTILIZES MICROINVERTERS. THERE ARE NO DC CIRCUITS OUTSIDE OF THE ARRAY PERIMETER OR INSIDE THE BUILDING. CABLES, WHEN RUN BETWEEN ARRAYS, SHALL BE ENCLOSED IN CONDUIT. BJORK GR I D - T I E D P V S Y S T E M BJ O R K R E S I D E N C E 60 6 S A L D E R S T PO R T A N G E L E S , W A 9 8 3 6 2 FIRE SAFETY PLAN DOC ID:E10F7A-1 DATE:4/13/23 CREATOR:K.P. REVIEWER:K.P. REVISIONS PV-7 Conductor, Conduit, and OCPD Sizing Validation 1. Maximum System DC Voltage Test 1.1. Enphase microinverter system w/35 Silfab SIL-380BK (380W)s Array Properties Array Type Microinverter Array System Description Enphase microinverter system w/35 Silfab SIL-380BK (380W)s Module SIL-380BK (380W) Highest number of modules in series in a PV Source Circuit 1 Design Low Temp.-6.6°C Module voc 45.1V Temp. Coefficient voc -0.126V/C NEC Code Calculations A. Maximum Voltage of PV Source Circuit 49.08V see NEC 690.7(A) NEC 690.7(A) requires that if the PV module manufacturer provides a temperature coefficient of open-circuit voltage, it must be used to calculate the PV array's maximum system voltage. It includes an information note recommending the use of the ASHRAE 'Extreme Annual Mean Minimum Design Dry Bulb Temperature' as the design low temperature. Using these values, the module Voc (45.1V) will increase to 49.08V at the design low temperature (-6.6°C). (-6.6°C - 25°C) X -0.126V/C + 45.1V = 49.08V The module Voc at the design low temperature is 49.08V. 49.08V X 1 = 49.08V NEC Code Validation Tests 1.PV Source Circuit maximum Voc must not exceed 600V 49.08V < 600V = true PASS 2. Wire, Conduit, and OCPD Code Compliance Validation 2.1. #1: Branch cables: Microinverter to Transition Box Circuit Section Properties Conductor 12 AWG THHN/THWN-2 in Enphase Q Cable, Copper Equipment Ground Conductor (EGC)6 AWG Bare, Copper OCPD(s)20A Raceway/Cable Cable Lowest Terminal Temperature Rating 90°C Maximum Wire Temperature 48°C Power Source Description Branch of 11 IQ8PLUS-72-2-US microinverters Power Source Current 13.31A Voltage 240V NEC Code Calculations A. Continuous Current 13.31A see NEC Article 100 Equipment maximum rated output current is 11 X 1.21A = 13.31A B. Ampacity of Conductor 30A see NEC Table 310.16 Ampacity (30°C) for a copper conductor with 90°C insulation in conduit/cable is 30A. C. Derated Ampacity of Conductor 25A see NEC 310.15(B)(2), NEC Table 310.15(C)(1), and NEC Article 100 The temperature factor for 90°C insulation at 48°C is 0.82. The fill factor for a conduit/cable that has 2 wires is 1. The ampacity derated for Conditions of Use is the product of the conductor ampacity (30A) multiplied by the temperature factor (0.82) and by the fill factor (1). 30A X 0.82 X 1 = 24.6A rounded to 25A D. Max Current for Terminal Temp. Rating 30A see NEC 110.14(C) The lowest temperature rating for this conductor at any termination is 90°C. Using the method specified in NEC 110.14(C), the maximum current permitted to ensure that the device terminal temperature does not exceed its 90°C rating would be the amount referenced in the 90°C column in NEC Table 310.16, which is 30A. E. Minimum Allowed OCPD Rating 17A see NEC 240.4 NEC 690.9(B)(1) requires OCPD be rated for no less than 1.25 times Continuous Current of the circuit. 13.31A X 1.25 = 16.64A F. Maximum Allowed OCPD Rating 20A see NEC 240.4(D) NEC 240.4(D) requires that OCPD rating not exceed 20A when protecting a Copper 12 AWG conductor. G. Minimum Required EGC Size 12 AWG see NEC Table 250.122 The smallest EGC size allowed is 12 AWG for OCPD rating 20A according to Table 250.122. NEC Code Validation Tests 1.OCPD rating must be at least 125% of Continuous Current (NEC 240.4) 20A >= 13.31A X 1.25 = true PASS 2.Derated ampacity must exceed OCPD rating, or rating of next smaller OCPD (NEC 240.4) 25A >= 20A (OCPD Rating) = true PASS 3.OCPD rating must not exceed max OCPD rating for conductor (NEC 240.4) 20 (OCPD Rating) <= 20A = true PASS 4.Derated Ampacity must be greater than or equal to the Continuous Current (NEC Article 100) 25A >= 13.31A = true PASS 5.Conductor Ampacity must be at least 125% of Continuous Current (NEC 215.2(A)(1)) 30A > 13.31A x 1.25 = true PASS 6.Max current for terminal must be at least 125% of the Continuous Current. (NEC 110.14(C)) 30A >= 13.31A X 1.25 = true PASS 7.EGC must meet code requirements for minimum size (NEC Table 250.122) 6 AWG >= 12 AWG = true PASS 2.2. #2: Branch cables: Microinverter to Transition Box Circuit Section Properties Conductor 12 AWG THHN/THWN-2 in Enphase Q Cable, Copper Equipment Ground Conductor (EGC)6 AWG Bare, Copper OCPD(s)20A Raceway/Cable Cable Lowest Terminal Temperature Rating 90°C Maximum Wire Temperature 48°C Power Source Description Branch of 13 IQ8PLUS-72-2-US microinverters Power Source Current 15.73A Voltage 240V NEC Code Calculations A. Continuous Current 15.73A see NEC Article 100 Equipment maximum rated output current is 13 X 1.21A = 15.73A B. Ampacity of Conductor 30A see NEC Table 310.16 Ampacity (30°C) for a copper conductor with 90°C insulation in conduit/cable is 30A. C. Derated Ampacity of Conductor 25A see NEC 310.15(B)(2), NEC Table 310.15(C)(1), and NEC Article 100 The temperature factor for 90°C insulation at 48°C is 0.82. The fill factor for a conduit/cable that has 2 wires is 1. The ampacity derated for Conditions of Use is the product of the conductor ampacity (30A) multiplied by the temperature factor (0.82) and by the fill factor (1). 30A X 0.82 X 1 = 24.6A rounded to 25A D. Max Current for Terminal Temp. Rating 30A see NEC 110.14(C) The lowest temperature rating for this conductor at any termination is 90°C. Using the method specified in NEC 110.14(C), the maximum current permitted to ensure that the device terminal temperature does not exceed its 90°C rating would be the amount referenced in the 90°C column in NEC Table 310.16, which is 30A. E. Minimum Allowed OCPD Rating 20A see NEC 240.4 NEC 690.9(B)(1) requires OCPD be rated for no less than 1.25 times Continuous Current of the circuit. 15.73A X 1.25 = 19.66A F. Maximum Allowed OCPD Rating 20A see NEC 240.4(D) NEC 240.4(D) requires that OCPD rating not exceed 20A when protecting a Copper 12 AWG conductor. G. Minimum Required EGC Size 12 AWG see NEC Table 250.122 The smallest EGC size allowed is 12 AWG for OCPD rating 20A according to Table 250.122. NEC Code Validation Tests 1.OCPD rating must be at least 125% of Continuous Current (NEC 240.4) 20A >= 15.73A X 1.25 = true PASS 2.Derated ampacity must exceed OCPD rating, or rating of next smaller OCPD (NEC 240.4) 25A >= 20A (OCPD Rating) = true PASS 3.OCPD rating must not exceed max OCPD rating for conductor (NEC 240.4) 20 (OCPD Rating) <= 20A = true PASS 4.Derated Ampacity must be greater than or equal to the Continuous Current (NEC Article 100) 25A >= 15.73A = true PASS 5.Conductor Ampacity must be at least 125% of Continuous Current (NEC 215.2(A)(1)) 30A > 15.73A x 1.25 = true PASS 6.Max current for terminal must be at least 125% of the Continuous Current. (NEC 110.14(C)) 30A >= 15.73A X 1.25 = true PASS 7.EGC must meet code requirements for minimum size (NEC Table 250.122) 6 AWG >= 12 AWG = true PASS 2.3. #3: MID Protected Loads Circuit: Microgrid Interconnect Device (MID) to Protected Loads Panel Circuit Section Properties Conductor 3 AWG THWN-2, Copper Equipment Ground Conductor (EGC)8 AWG THWN-2, Copper OCPD(s)100A Raceway/Cable 1.25" dia. PVC-40 Lowest Terminal Temperature Rating 75°C Maximum Wire Temperature 26°C Load(s) Description Protected Loads Continuous Load(s) Current 80A NEC Code Calculations A. Continuous Current 80A see NEC Article 100 Current rating of load is 80 A B. Ampacity of Conductor 115A see NEC Table 310.16 Ampacity (30°C) for a copper conductor with 90°C insulation in conduit/cable is 115A. C. Derated Ampacity of Conductor 115A see NEC 310.15(B)(2), NEC Table 310.15(C)(1), and NEC Article 100 The temperature factor for 90°C insulation at 26°C is 1. The fill factor for a conduit/cable that has 3 wires is 1. The ampacity derated for Conditions of Use is the product of the conductor ampacity (115A) multiplied by the temperature factor (1) and by the fill factor (1). 115A X 1 X 1 = 115.0A D. Max Current for Terminal Temp. Rating 100A see NEC 110.14(C) The lowest temperature rating for this conductor at any termination is 75°C. Using the method specified in NEC 110.14(C), the maximum current permitted to ensure that the device terminal temperature does not exceed its 75°C rating would be the amount referenced in the 75°C column in NEC Table 310.16, which is 100A. E. Minimum Allowed OCPD Rating 100A see NEC 240.4 NEC 690.9(B)(1) requires OCPD be rated for no less than 1.25 times Continuous Current of the circuit. 80A X 1.25 = 100A F. Minimum Required EGC Size 8 AWG see NEC Table 250.122 The smallest EGC size allowed is 8 AWG for OCPD rating 100A according to Table 250.122. G. Minimum Recommended Conduit Size 1.0" dia. see NEC 300.17 The total area of all conductors is 0.3285in². With a maximum fill rate of 0.4, the recommended conduit diameter is 1.0. Qty Description Size Type Area Total Area 2 Conductor 3 AWG THWN-2 0.0973in²0.1946in² 1 Neutral 3 AWG THWN-2 0.0973in²0.0973in² 1 Equipment Ground 8 AWG THWN-2 0.0366in²0.0366in² 4 0.3285in² 0.3285in² / 0.4 = 0.8213in² (Corresponding to a diameter of 1.0") NEC Code Validation Tests 1.OCPD rating must be at least 125% of Continuous Current (NEC 240.4) 100A >= 80A X 1.25 = true PASS 2.Derated ampacity must exceed OCPD rating, or rating of next smaller OCPD (NEC 240.4) 115A >= 100A (OCPD Rating) = true PASS 3.Derated Ampacity must be greater than or equal to the Continuous Current (NEC Article 100) 115A >= 80A = true PASS 4.Conductor Ampacity must be at least 125% of Continuous Current (NEC 215.2(A)(1)) 115A > 80A x 1.25 = true PASS 5.Max current for terminal must be at least 125% of the Continuous Current. (NEC 110.14(C)) 100A >= 80A X 1.25 = true PASS 6.EGC must meet code requirements for minimum size (NEC Table 250.122) 8 AWG >= 8 AWG = true PASS 7.Conduit must meet code recommendation for minimum size (NEC 300.17) 1.25in. >= 1.0in. = true PASS 2.4. #4: AC Branch Output: Transition Box to AC Combiner Circuit Section Properties Conductor 12 AWG THWN-2, Copper Equipment Ground Conductor (EGC)12 AWG THWN-2, Copper OCPD(s)20A Raceway/Cable 0.75" dia. EMT Lowest Terminal Temperature Rating 90°C Maximum Wire Temperature 26°C Power Source Description Branch of 11 IQ8PLUS-72-2-US microinverters Power Source Current 13.31A Voltage 240V NEC Code Calculations A. Continuous Current 13.31A see NEC Article 100 Equipment maximum rated output current is 11 X 1.21A = 13.31A B. Ampacity of Conductor 30A see NEC Table 310.16 Ampacity (30°C) for a copper conductor with 90°C insulation in conduit/cable is 30A. C. Derated Ampacity of Conductor 24A see NEC 310.15(B)(2), NEC Table 310.15(C)(1), and NEC Article 100 The temperature factor for 90°C insulation at 26°C is 1. The fill factor for a conduit/cable that has 6 wires is 0.8. The ampacity derated for Conditions of Use is the product of the conductor ampacity (30A) multiplied by the temperature factor (1) and by the fill factor (0.8). 30A X 1 X 0.8 = 24.0A D. Max Current for Terminal Temp. Rating 30A see NEC 110.14(C) The lowest temperature rating for this conductor at any termination is 90°C. Using the method specified in NEC 110.14(C), the maximum current permitted to ensure that the device terminal temperature does not exceed its 90°C rating would be the amount referenced in the 90°C column in NEC Table 310.16, which is 30A. E. Minimum Allowed OCPD Rating 17A see NEC 240.4 NEC 690.9(B)(1) requires OCPD be rated for no less than 1.25 times Continuous Current of the circuit. 13.31A X 1.25 = 16.64A F. Maximum Allowed OCPD Rating 20A see NEC 240.4(D) NEC 240.4(D) requires that OCPD rating not exceed 20A when protecting a Copper 12 AWG conductor. G. Minimum Required EGC Size 12 AWG see NEC Table 250.122 The smallest EGC size allowed is 12 AWG for OCPD rating 20A according to Table 250.122. H. Minimum Recommended Conduit Size 0.5" dia. see NEC 300.17 The total area of all conductors is 0.1197in². With a maximum fill rate of 0.4, the recommended conduit diameter is 0.5. Qty Description Size Type Area Total Area 6 Conductor 12 AWG THWN-2 0.0133in²0.0798in² 3 Equipment Ground 12 AWG THWN-2 0.0133in²0.0399in² 9 0.1197in² 0.1197in² / 0.4 = 0.2993in² (Corresponding to a diameter of 0.5") NEC Code Validation Tests 1.OCPD rating must be at least 125% of Continuous Current (NEC 240.4) 20A >= 13.31A X 1.25 = true PASS 2.Derated ampacity must exceed OCPD rating, or rating of next smaller OCPD (NEC 240.4) 24A >= 20A (OCPD Rating) = true PASS 3.OCPD rating must not exceed max OCPD rating for conductor (NEC 240.4) 20 (OCPD Rating) <= 20A = true PASS 4.Derated Ampacity must be greater than or equal to the Continuous Current (NEC Article 100) 24A >= 13.31A = true PASS 5.Conductor Ampacity must be at least 125% of Continuous Current (NEC 215.2(A)(1)) 30A > 13.31A x 1.25 = true PASS 6.Max current for terminal must be at least 125% of the Continuous Current. (NEC 110.14(C)) 30A >= 13.31A X 1.25 = true PASS 7.EGC must meet code requirements for minimum size (NEC Table 250.122) 12 AWG >= 12 AWG = true PASS 8.Conduit must meet code recommendation for minimum size (NEC 300.17) 0.75in. >= 0.5in. = true PASS 2.5. #5: AC Branch Output: Transition Box to AC Combiner Circuit Section Properties Conductor 12 AWG THWN-2, Copper Equipment Ground Conductor (EGC)12 AWG THWN-2, Copper OCPD(s)20A Raceway/Cable 0.75" dia. EMT Lowest Terminal Temperature Rating 90°C Maximum Wire Temperature 26°C Power Source Description Branch of 13 IQ8PLUS-72-2-US microinverters Power Source Current 15.73A Voltage 240V NEC Code Calculations A. Continuous Current 15.73A see NEC Article 100 Equipment maximum rated output current is 13 X 1.21A = 15.73A B. Ampacity of Conductor 30A see NEC Table 310.16 Ampacity (30°C) for a copper conductor with 90°C insulation in conduit/cable is 30A. C. Derated Ampacity of Conductor 24A see NEC 310.15(B)(2), NEC Table 310.15(C)(1), and NEC Article 100 The temperature factor for 90°C insulation at 26°C is 1. The fill factor for a conduit/cable that has 6 wires is 0.8. The ampacity derated for Conditions of Use is the product of the conductor ampacity (30A) multiplied by the temperature factor (1) and by the fill factor (0.8). 30A X 1 X 0.8 = 24.0A D. Max Current for Terminal Temp. Rating 30A see NEC 110.14(C) The lowest temperature rating for this conductor at any termination is 90°C. Using the method specified in NEC 110.14(C), the maximum current permitted to ensure that the device terminal temperature does not exceed its 90°C rating would be the amount referenced in the 90°C column in NEC Table 310.16, which is 30A. E. Minimum Allowed OCPD Rating 20A see NEC 240.4 NEC 690.9(B)(1) requires OCPD be rated for no less than 1.25 times Continuous Current of the circuit. 15.73A X 1.25 = 19.66A F. Maximum Allowed OCPD Rating 20A see NEC 240.4(D) NEC 240.4(D) requires that OCPD rating not exceed 20A when protecting a Copper 12 AWG conductor. G. Minimum Required EGC Size 12 AWG see NEC Table 250.122 The smallest EGC size allowed is 12 AWG for OCPD rating 20A according to Table 250.122. H. Minimum Recommended Conduit Size 0.5" dia. see NEC 300.17 The total area of all conductors is 0.1197in². With a maximum fill rate of 0.4, the recommended conduit diameter is 0.5. Qty Description Size Type Area Total Area 6 Conductor 12 AWG THWN-2 0.0133in²0.0798in² 3 Equipment Ground 12 AWG THWN-2 0.0133in²0.0399in² 9 0.1197in² 0.1197in² / 0.4 = 0.2993in² (Corresponding to a diameter of 0.5") NEC Code Validation Tests 1.OCPD rating must be at least 125% of Continuous Current (NEC 240.4) 20A >= 15.73A X 1.25 = true PASS 2.Derated ampacity must exceed OCPD rating, or rating of next smaller OCPD (NEC 240.4) 24A >= 20A (OCPD Rating) = true PASS 3.OCPD rating must not exceed max OCPD rating for conductor (NEC 240.4) 20 (OCPD Rating) <= 20A = true PASS 4.Derated Ampacity must be greater than or equal to the Continuous Current (NEC Article 100) 24A >= 15.73A = true PASS 5.Conductor Ampacity must be at least 125% of Continuous Current (NEC 215.2(A)(1)) 30A > 15.73A x 1.25 = true PASS 6.Max current for terminal must be at least 125% of the Continuous Current. (NEC 110.14(C)) 30A >= 15.73A X 1.25 = true PASS 7.EGC must meet code requirements for minimum size (NEC Table 250.122) 12 AWG >= 12 AWG = true PASS 8.Conduit must meet code recommendation for minimum size (NEC 300.17) 0.75in. >= 0.5in. = true PASS 2.6. #6: AC Combiner Output: AC Combiner to Microgrid Interconnect Device (MID) Circuit Section Properties Conductor 6 AWG THWN-2, Copper Equipment Ground Conductor (EGC)10 AWG THWN-2, Copper OCPD(s)60A Raceway/Cable 0.75" dia. EMT Lowest Terminal Temperature Rating 90°C Maximum Wire Temperature 26°C Power Source Description Enphase microinverter system w/35 Silfab SIL-380BK (380W)s Power Source Current 42.35A Voltage 240V NEC Code Calculations A. Continuous Current 42.35A see NEC Article 100 Equipment maximum rated output current is 42.35A B. Ampacity of Conductor 75A see NEC Table 310.16 Ampacity (30°C) for a copper conductor with 90°C insulation in conduit/cable is 75A. C. Derated Ampacity of Conductor 60A see NEC 310.15(B)(2), NEC Table 310.15(C)(1), and NEC Article 100 The temperature factor for 90°C insulation at 26°C is 1. The fill factor for a conduit/cable that has 4 wires is 0.8. The ampacity derated for Conditions of Use is the product of the conductor ampacity (75A) multiplied by the temperature factor (1) and by the fill factor (0.8). 75A X 1 X 0.8 = 60.0A D. Max Current for Terminal Temp. Rating 75A see NEC 110.14(C) The lowest temperature rating for this conductor at any termination is 90°C. Using the method specified in NEC 110.14(C), the maximum current permitted to ensure that the device terminal temperature does not exceed its 90°C rating would be the amount referenced in the 90°C column in NEC Table 310.16, which is 75A. E. Minimum Allowed OCPD Rating 53A see NEC 240.4 NEC 690.9(B)(1) requires OCPD be rated for no less than 1.25 times Continuous Current of the circuit. 42.35A X 1.25 = 52.94A F. Minimum Required EGC Size 10 AWG see NEC Table 250.122 The smallest EGC size allowed is 10 AWG for OCPD rating 60A according to Table 250.122. G. Minimum Recommended Conduit Size 0.75" dia. see NEC 300.17 The total area of all conductors is 0.199in². With a maximum fill rate of 0.4, the recommended conduit diameter is 0.75. Qty Description Size Type Area Total Area 2 Conductor 6 AWG THWN-2 0.0507in²0.1014in² 1 Equipment Ground 10 AWG THWN-2 0.0211in²0.0211in² 2 Conductor 12 AWG THWN-2 0.0133in²0.0266in² 1 Neutral 8 AWG THWN-2 0.0366in²0.0366in² 1 Equipment Ground 12 AWG THWN-2 0.0133in²0.0133in² 7 0.199in² 0.199in² / 0.4 = 0.4975in² (Corresponding to a diameter of 0.75") NEC Code Validation Tests 1.OCPD rating must be at least 125% of Continuous Current (NEC 240.4) 60A >= 42.35A X 1.25 = true PASS 2.Derated ampacity must exceed OCPD rating, or rating of next smaller OCPD (NEC 240.4(B) and NEC 240.4) 60A >= 50A (Next Smaller OCPD Rating) = true PASS 3.Derated Ampacity must be greater than or equal to the Continuous Current (NEC Article 100) 60A >= 42.35A = true PASS 4.Conductor Ampacity must be at least 125% of Continuous Current (NEC 215.2(A)(1)) 75A > 42.35A x 1.25 = true PASS 5.Max current for terminal must be at least 125% of the Continuous Current. (NEC 110.14(C)) 75A >= 42.35A X 1.25 = true PASS 6.EGC must meet code requirements for minimum size (NEC Table 250.122) 10 AWG >= 10 AWG = true PASS 7.Conduit must meet code recommendation for minimum size (NEC 300.17) 0.75in. >= 0.75in. = true PASS 2.7. #7: Energy Storage System Output: Energy Storage System to Energy Storage System Circuit Section Properties Conductor 8 AWG THWN-2, Copper Equipment Ground Conductor (EGC)10 AWG THWN-2, Copper OCPD(s)40A Raceway/Cable 0.75" dia. EMT Lowest Terminal Temperature Rating 75°C Maximum Wire Temperature 26°C Power Source Description (2) 10.08kWh Energy Storage Systems Power Source Current 31.8A Voltage 240V NEC Code Calculations A. Continuous Current 31.8A see NEC Article 100 Equipment maximum rated output current is 2 X 15.9A = 31.8A B. Ampacity of Conductor 55A see NEC Table 310.16 Ampacity (30°C) for a copper conductor with 90°C insulation in conduit/cable is 55A. C. Derated Ampacity of Conductor 55A see NEC 310.15(B)(2), NEC Table 310.15(C)(1), and NEC Article 100 The temperature factor for 90°C insulation at 26°C is 1. The fill factor for a conduit/cable that has 2 wires is 1. The ampacity derated for Conditions of Use is the product of the conductor ampacity (55A) multiplied by the temperature factor (1) and by the fill factor (1). 55A X 1 X 1 = 55.0A D. Max Current for Terminal Temp. Rating 50A see NEC 110.14(C) The lowest temperature rating for this conductor at any termination is 75°C. Using the method specified in NEC 110.14(C), the maximum current permitted to ensure that the device terminal temperature does not exceed its 75°C rating would be the amount referenced in the 75°C column in NEC Table 310.16, which is 50A. E. Minimum Allowed OCPD Rating 40A see NEC 240.4 NEC 690.9(B)(1) requires OCPD be rated for no less than 1.25 times Continuous Current of the circuit. 31.8A X 1.25 = 39.75A F. Minimum Required EGC Size 10 AWG see NEC Table 250.122 The smallest EGC size allowed is 10 AWG for OCPD rating 40A according to Table 250.122. G. Minimum Recommended Conduit Size 0.5" dia. see NEC 300.17 The total area of all conductors is 0.0943in². With a maximum fill rate of 0.4, the recommended conduit diameter is 0.5. Qty Description Size Type Area Total Area 2 Conductor 8 AWG THWN-2 0.0366in²0.0732in² 1 Equipment Ground 10 AWG THWN-2 0.0211in²0.0211in² 3 0.0943in² 0.0943in² / 0.4 = 0.2358in² (Corresponding to a diameter of 0.5") NEC Code Validation Tests 1.OCPD rating must be at least 125% of Continuous Current (NEC 240.4) 40A >= 31.8A X 1.25 = true PASS 2.Derated ampacity must exceed OCPD rating, or rating of next smaller OCPD (NEC 240.4) 55A >= 40A (OCPD Rating) = true PASS 3.Derated Ampacity must be greater than or equal to the Continuous Current (NEC Article 100) 55A >= 31.8A = true PASS 4.Conductor Ampacity must be at least 125% of Continuous Current (NEC 215.2(A)(1)) 55A > 31.8A x 1.25 = true PASS 5.Max current for terminal must be at least 125% of the Continuous Current. (NEC 110.14(C)) 50A >= 31.8A X 1.25 = true PASS 6.EGC must meet code requirements for minimum size (NEC Table 250.122) 10 AWG >= 10 AWG = true PASS 7.Conduit must meet code recommendation for minimum size (NEC 300.17) 0.75in. >= 0.5in. = true PASS 2.8. #8: MID Grid Connection Circuit: Microgrid Interconnect Device (MID) to Utility Disconnect Circuit Section Properties Conductor 3 AWG THWN-2, Copper Equipment Ground Conductor (EGC)8 AWG THWN-2, Copper OCPD(s)100A Raceway/Cable 1.25" dia. PVC-40 Lowest Terminal Temperature Rating 75°C Maximum Wire Temperature 26°C Load(s) Description Protected Loads Continuous Load(s) Current 80A NEC Code Calculations A. Continuous Current 80A see NEC Article 100 Current rating of load is 80 A B. Ampacity of Conductor 115A see NEC Table 310.16 Ampacity (30°C) for a copper conductor with 90°C insulation in conduit/cable is 115A. C. Derated Ampacity of Conductor 115A see NEC 310.15(B)(2), NEC Table 310.15(C)(1), and NEC Article 100 The temperature factor for 90°C insulation at 26°C is 1. The fill factor for a conduit/cable that has 3 wires is 1. The ampacity derated for Conditions of Use is the product of the conductor ampacity (115A) multiplied by the temperature factor (1) and by the fill factor (1). 115A X 1 X 1 = 115.0A D. Max Current for Terminal Temp. Rating 100A see NEC 110.14(C) The lowest temperature rating for this conductor at any termination is 75°C. Using the method specified in NEC 110.14(C), the maximum current permitted to ensure that the device terminal temperature does not exceed its 75°C rating would be the amount referenced in the 75°C column in NEC Table 310.16, which is 100A. E. Minimum Allowed OCPD Rating 100A see NEC 240.4 NEC 690.9(B)(1) requires OCPD be rated for no less than 1.25 times Continuous Current of the circuit. 80A X 1.25 = 100A F. Minimum Required EGC Size 8 AWG see NEC Table 250.122 The smallest EGC size allowed is 8 AWG for OCPD rating 100A according to Table 250.122. G. Minimum Recommended Conduit Size 1.0" dia. see NEC 300.17 The total area of all conductors is 0.3285in². With a maximum fill rate of 0.4, the recommended conduit diameter is 1.0. Qty Description Size Type Area Total Area 2 Conductor 3 AWG THWN-2 0.0973in²0.1946in² 1 Neutral 3 AWG THWN-2 0.0973in²0.0973in² 1 Equipment Ground 8 AWG THWN-2 0.0366in²0.0366in² 4 0.3285in² 0.3285in² / 0.4 = 0.8213in² (Corresponding to a diameter of 1.0") NEC Code Validation Tests 1.OCPD rating must be at least 125% of Continuous Current (NEC 240.4) 100A >= 80A X 1.25 = true PASS 2.Derated ampacity must exceed OCPD rating, or rating of next smaller OCPD (NEC 240.4) 115A >= 100A (OCPD Rating) = true PASS 3.Derated Ampacity must be greater than or equal to the Continuous Current (NEC Article 100) 115A >= 80A = true PASS 4.Conductor Ampacity must be at least 125% of Continuous Current (NEC 215.2(A)(1)) 115A > 80A x 1.25 = true PASS 5.Max current for terminal must be at least 125% of the Continuous Current. (NEC 110.14(C)) 100A >= 80A X 1.25 = true PASS 6.EGC must meet code requirements for minimum size (NEC Table 250.122) 8 AWG >= 8 AWG = true PASS 7.Conduit must meet code recommendation for minimum size (NEC 300.17) 1.25in. >= 1.0in. = true PASS 2.9. #9: Utility Disconnect Output: Utility Disconnect to Main Service Panel Circuit Section Properties Conductor 3 AWG THWN-2, Copper Equipment Ground Conductor (EGC)N/A OCPD(s)100A Raceway/Cable 1.25" dia. PVC-40 Lowest Terminal Temperature Rating 75°C Maximum Wire Temperature 26°C Load(s) Description Protected Loads Continuous Load(s) Current 80A NEC Code Calculations A. Continuous Current 80A see NEC Article 100 Current rating of load is 80 A B. Ampacity of Conductor 115A see NEC Table 310.16 Ampacity (30°C) for a copper conductor with 90°C insulation in conduit/cable is 115A. C. Derated Ampacity of Conductor 115A see NEC 310.15(B)(2), NEC Table 310.15(C)(1), and NEC Article 100 The temperature factor for 90°C insulation at 26°C is 1. The fill factor for a conduit/cable that has 3 wires is 1. The ampacity derated for Conditions of Use is the product of the conductor ampacity (115A) multiplied by the temperature factor (1) and by the fill factor (1). 115A X 1 X 1 = 115.0A D. Max Current for Terminal Temp. Rating 100A see NEC 110.14(C) The lowest temperature rating for this conductor at any termination is 75°C. Using the method specified in NEC 110.14(C), the maximum current permitted to ensure that the device terminal temperature does not exceed its 75°C rating would be the amount referenced in the 75°C column in NEC Table 310.16, which is 100A. E. Minimum Allowed OCPD Rating 100A see NEC 240.4 NEC 690.9(B)(1) requires OCPD be rated for no less than 1.25 times Continuous Current of the circuit. 80A X 1.25 = 100A F. Minimum Recommended Conduit Size 1.0" dia. see NEC 300.17 The total area of all conductors is 0.2919in². With a maximum fill rate of 0.4, the recommended conduit diameter is 1.0. Qty Description Size Type Area Total Area 2 Conductor 3 AWG THWN-2 0.0973in²0.1946in² 1 Neutral 3 AWG THWN-2 0.0973in²0.0973in² 3 0.2919in² 0.2919in² / 0.4 = 0.7298in² (Corresponding to a diameter of 1.0") NEC Code Validation Tests 1.OCPD rating must be at least 125% of Continuous Current (NEC 240.4) 100A >= 80A X 1.25 = true PASS 2.Derated ampacity must exceed OCPD rating, or rating of next smaller OCPD (NEC 240.4) 115A >= 100A (OCPD Rating) = true PASS 3.Derated Ampacity must be greater than or equal to the Continuous Current (NEC Article 100) 115A >= 80A = true PASS 4.Conductor Ampacity must be at least 125% of Continuous Current (NEC 215.2(A)(1)) 115A > 80A x 1.25 = true PASS 5.Max current for terminal must be at least 125% of the Continuous Current. (NEC 110.14(C)) 100A >= 80A X 1.25 = true PASS 6.Conduit must meet code recommendation for minimum size (NEC 300.17) 1.25in. >= 1.0in. = true PASS 2.10. #10: Rapid Shutdown Initiator Circuit: MID RS Initiator terminals to Rapid Shutdown Initiator Circuit Section Properties Conductor 12 AWG THWN-2, Copper Equipment Ground Conductor (EGC)12 AWG THWN-2, Copper OCPD(s)N/A Raceway/Cable 0.75" dia. EMT Lowest Terminal Temperature Rating 75°C Maximum Wire Temperature 26°C Power Source Description MID RS Initiator terminals Power Source Current 16A Voltage 600V NEC Code Calculations A. Continuous Current 16A see NEC 706.30(A)(1) The ESS circuit current is the larger of the input or output current. B. Ampacity of Conductor 30A see NEC Table 310.16 Ampacity (30°C) for a copper conductor with 90°C insulation in conduit/cable is 30A. C. Derated Ampacity of Conductor 24A see NEC 310.15(B)(2), NEC Table 310.15(C)(1), and NEC Article 100 The temperature factor for 90°C insulation at 26°C is 1. The fill factor for a conduit/cable that has 4 wires is 0.8. The ampacity derated for Conditions of Use is the product of the conductor ampacity (30A) multiplied by the temperature factor (1) and by the fill factor (0.8). 30A X 1 X 0.8 = 24.0A D. Max Current for Terminal Temp. Rating 25A see NEC 110.14(C) The lowest temperature rating for this conductor at any termination is 75°C. Using the method specified in NEC 110.14(C), the maximum current permitted to ensure that the device terminal temperature does not exceed its 75°C rating would be the amount referenced in the 75°C column in NEC Table 310.16, which is 25A. E. Minimum Required EGC Size 12 AWG see NEC Table 250.122 The smallest EGC size allowed is 12 AWG for OCPD rating 20A according to Table 250.122. F. Minimum Recommended Conduit Size 0.5" dia. see NEC 300.17 The total area of all conductors is 0.0798in². With a maximum fill rate of 0.4, the recommended conduit diameter is 0.5. Qty Description Size Type Area Total Area 4 Conductor 12 AWG THWN-2 0.0133in²0.0532in² 2 Equipment Ground 12 AWG THWN-2 0.0133in²0.0266in² 6 0.0798in² 0.0798in² / 0.4 = 0.1995in² (Corresponding to a diameter of 0.5") NEC Code Validation Tests 1.Derated Ampacity must be greater than or equal to the Continuous Current (NEC Article 100) 24A >= 16A = true PASS 2.Conductor Ampacity must be at least 125% of Continuous Current (NEC 215.2(A)(1)) 30A > 16A x 1.25 = true PASS 3.Max current for terminal must be at least 125% of the Continuous Current. (NEC 110.14(C)) 25A >= 16A X 1.25 = true PASS 4.EGC must meet code requirements for minimum size (NEC Table 250.122) 12 AWG >= 12 AWG = true PASS 5.Conduit must meet code recommendation for minimum size (NEC 300.17) 0.75in. >= 0.5in. = true PASS 2.11. #11: Auxiliary AC Power Supply: Microgrid Interconnect Device (MID) to IQ Gateway Circuit Section Properties Conductor 12 AWG THWN-2, Copper Equipment Ground Conductor (EGC)12 AWG THWN-2, Copper OCPD(s)15A Raceway/Cable 0.75" dia. EMT Lowest Terminal Temperature Rating 75°C Maximum Wire Temperature 26°C Load(s) Description IQ Gateway Continuous Load(s) Current 12A NEC Code Calculations A. Continuous Current 12A see NEC Article 100 Current rating of load is 12 A B. Ampacity of Conductor 30A see NEC Table 310.16 Ampacity (30°C) for a copper conductor with 90°C insulation in conduit/cable is 30A. C. Derated Ampacity of Conductor 24A see NEC 310.15(B)(2), NEC Table 310.15(C)(1), and NEC Article 100 The temperature factor for 90°C insulation at 26°C is 1. The fill factor for a conduit/cable that has 5 wires is 0.8. The ampacity derated for Conditions of Use is the product of the conductor ampacity (30A) multiplied by the temperature factor (1) and by the fill factor (0.8). 30A X 1 X 0.8 = 24.0A D. Max Current for Terminal Temp. Rating 25A see NEC 110.14(C) The lowest temperature rating for this conductor at any termination is 75°C. Using the method specified in NEC 110.14(C), the maximum current permitted to ensure that the device terminal temperature does not exceed its 75°C rating would be the amount referenced in the 75°C column in NEC Table 310.16, which is 25A. E. Minimum Allowed OCPD Rating 15A see NEC 240.4 NEC 690.9(B)(1) requires OCPD be rated for no less than 1.25 times Continuous Current of the circuit. 12A X 1.25 = 15A F. Maximum Allowed OCPD Rating 20A see NEC 240.4(D) NEC 240.4(D) requires that OCPD rating not exceed 20A when protecting a Copper 12 AWG conductor. G. Minimum Required EGC Size 14 AWG see NEC Table 250.122 The smallest EGC size allowed is 14 AWG for OCPD rating 15A according to Table 250.122. H. Minimum Recommended Conduit Size 0.75" dia. see NEC 300.17 The total area of all conductors is 0.199in². With a maximum fill rate of 0.4, the recommended conduit diameter is 0.75. Qty Description Size Type Area Total Area 2 Conductor 6 AWG THWN-2 0.0507in²0.1014in² 1 Equipment Ground 10 AWG THWN-2 0.0211in²0.0211in² 2 Conductor 12 AWG THWN-2 0.0133in²0.0266in² 1 Neutral 8 AWG THWN-2 0.0366in²0.0366in² 1 Equipment Ground 12 AWG THWN-2 0.0133in²0.0133in² 7 0.199in² 0.199in² / 0.4 = 0.4975in² (Corresponding to a diameter of 0.75") NEC Code Validation Tests 1.OCPD rating must be at least 125% of Continuous Current (NEC 240.4) 15A >= 12A X 1.25 = true PASS 2.Derated ampacity must exceed OCPD rating, or rating of next smaller OCPD (NEC 240.4) 24A >= 15A (OCPD Rating) = true PASS 3.OCPD rating must not exceed max OCPD rating for conductor (NEC 240.4) 15 (OCPD Rating) <= 20A = true PASS 4.Derated Ampacity must be greater than or equal to the Continuous Current (NEC Article 100) 24A >= 12A = true PASS 5.Conductor Ampacity must be at least 125% of Continuous Current (NEC 215.2(A)(1)) 30A > 12A x 1.25 = true PASS 6.Max current for terminal must be at least 125% of the Continuous Current. (NEC 110.14(C)) 25A >= 12A X 1.25 = true PASS 7.EGC must meet code requirements for minimum size (NEC Table 250.122) 12 AWG >= 14 AWG = true PASS 8.Conduit must meet code recommendation for minimum size (NEC 300.17) 0.75in. >= 0.75in. = true PASS SIL-380 BK ** SIL-380BK* Chubb provides error and omission insurance to Silfab Solar Inc. NOT JUST ANOTHER SOLAR PANEL. Introducing Silfab Elite. The highest efficiency solar panel (up to 21.4%)** manufactured exclusively in the United States. SILFABELITE.COM ELECTRICAL SPECIFICATIONS 380 Test Conditions STC NOCT Module Power (Pmax)Wp 380 284.6 Maximum power voltage (Vpmax)V 38.88 36.41 Maximum power current (Ipmax)A 9.79 7.82 Open circuit voltage (Voc)V 45.13 42.36 Short circuit current (Isc)A 10.50 8.46 Module efficiency %21.4 20.0 Maximum system voltage (VDC)V 1000 Series fuse rating A 20 Power Tolerance Wp 0 to +10 Measurement conditions: STC 1000 W/m2 • AM 1.5 • Temperature 25 °C • NOCT 800 W/m² • AM 1.5 • Measurement uncertainty ≤ 3% Sun simulator calibration reference modules from Fraunhofer Institute. Electrical characteristics may vary by ±5% and power by 0 to +10W. SHIPPING SPECS Modules Per Pallet:26 or 26 (California) Pallets Per Truck 34 or 32 (California) Modules Per Truck 884 or 832 (California) TEMPERATURE RATINGS Temperature Coefficient Isc +0.046 %/°C Temperature Coefficient Voc -0.279 %/°C Temperature Coefficient Pmax -0.377 %/°C NOCT (± 2°C)43.5 °C Operating temperature -40/+85 °C WARRANTIES Module product workmanship warranty 25 years** Linear power performance guarantee 30 years ≥ 97.1% end 1st yr ≥ 91.6% end 12th yr ≥ 85.1% end 25th yr ≥ 82.6% end 30th yr CERTIFICATIONS Product ULC ORD C1703, UL1703, CEC listed, UL 61215-1/-1-1/-2, UL 61730-1/-2, IEC 61215-1/-1-1/-2. IEC 61730-1/-2, CSA C22.2#61730-1/-2, IEC 62716 Ammonia Corrosion; IEC61701:2011 Salt Mist Corrosion Certifed, UL Fire Rating: Type 1 Factory ISO9001:2015 MECHANICAL PROPERTIES / COMPONENTS METRIC IMPERIAL Module weight 19.0±0.2 kg 41.9±0.4 lbs Dimensions (H x L x D)1795 mm x 990 mm x 38 mm 70.67 in x 38.98 in x 1.5 in Maximum surface load (wind/snow)*4000 Pa rear load / 5400 Pa front load 83.5/112.8 lb/ft^2 Hail impact resistance ø 25 mm at 83 km/h ø 1 in at 51.6 mph Cells 66 high efficiency back contact mono-PERC c-Si cells 66 high efficiency back contact mono-PERC c-Si cells Glass 3.2 mm high transmittance, tempered, DSM anti-reflective coating 0.126 in high transmittance, tempered, DSM anti-reflective coating Cables and connectors (refer to installation manual)1200 mm ø 5.7 mm, MC4 from Staubli 47.24 in, ø 0.22 in, MC4 from Staubli Backsheet Multilayer, integrated insulation film and electrically conductive backsheet, superior hydrolysis and UV resistance, fluorine- free PV backsheet Frame Anodized Aluminum (Black) Bypass diodes 3 diodes-30SQ045T (45V max DC blocking voltage, 30A max forward rectified current) Junction Box UL 3730 Certified, IP67 rated FR A M E P R O F I L E * Warning. Read the Safety and Installation Manual for mounting specifications and before handling, installing and operating modules. ** 12 year extendable to 25 years subject to registration and conditions outlined under “Warranty” at silfabsolar.com PAN files generated from 3rd party performance data are available for download at: silfabsolar.com/downloads SILFAB SOLAR INC. 800 Cornwall Ave Bellingham WA 98225 USA T +1 360.569.4733 info@silfabsolar.com SILFABSOLAR.COM 1770 Port Drive Burlington WA 98233 USA T +1 360.569.4733 240 Courtneypark Drive East Mississauga ON L5T 2Y3 Canada T +1 905.255.2501 F +1 905.696.0267 Silfab - SIL-380-BK-20210803 No reproduction of any kind is allowed without permission. Data and information is subject to modifications without notice. © Silfab Solar Inc., 2021. Silfab SolarTM is a trademark of Silfab Solar Inc. DATA SHEET IQ8 and IQ8+ Microinverters Our newest IQ8 Microinverters are the industry’s first microgrid-forming, software defined microinverters with split-phase power conversion capability to convert DC power to AC power efficiently. The brain of the semiconductor-based microinverter is our proprietary application specific integrated circuit (ASIC) which enables the microinverter to operate in grid-tied or off-grid modes. This chip is built in advanced 55nm technology with high speed digital logic and has superfast response times to changing loads and grid events, alleviating constraints on battery sizing for home energy systems. Easy to install • Lightweight and compact with plug-n- play connectors • Power Line Communication (PLC) between components • Faster installation with simple two-wire cabling High productivity and reliability • Produce power even when the grid is down* • More than one million cumulative hours of testing • Class II double-insulated enclosure • Optimized for the latest high-powered PV modules Microgrid-forming • Complies with the latest advanced grid support** • Remote automatic updates for the latest grid requirements • Configurable to support a wide range of grid profiles • Meets CA Rule 21 (UL 1741-SA) and IEEE 1547:2018 (UL 1741-SB 3rd Ed.) Note: IQ8 Microinverters cannot be mixed together with previous generations of Enphase microinverters (IQ7 Series, IQ6 Series, etc) in the same system. © 2022 Enphase Energy. All rights reserved. Enphase, the Enphase logo, IQ8 Microinverters, and other names are trademarks of Enphase Energy, Inc. Data subject to change. *Only when installed with IQ System Controller 2, meets UL 1741. **IQ8 and IQ8Plus support split-phase, 240V installations only. Part of the Enphase Energy System, IQ8 Series Microinverters integrate with the IQ Battery, IQ Gateway, and the Enphase App monitoring and analysis software. IQ8 Series Microinverters redefine reliability standards with more than one million cumulative hours of power-on testing, enabling an industry-leading limited warranty of up to 25 years. Connect PV modules quickly and easily to IQ8 Series Microinverters using the included Q-DCC-2 adapter cable with plug-n-play MC4 connectors. IQ8 Series Microinverters are UL listed as PV Rapid Shutdown Equipment and conform with various regulations, when installed according to manufacturer’s instructions. IQ8SP-12A-DS-0067-03-EN-US-2022-12-27 (1) Pairing PV modules with wattage above the limit may result in additional clipping losses. See the compatibility calculator at https://link.enphase.com/module-compatibility. (2) Nominal voltage range can be extended beyond nominal if required by the utility. (3) Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. IQ8 and IQ8+ Microinverters INPUT DATA (DC)IQ8-60-2-US IQ8PLUS-72-2-US Commonly used module pairings1 W 235 – 350 235 – 440 Module compatibility 60-cell / 120 half-cell 54-cell / 108 half-cell, 60-cell / 120 half-cell, 66-cell / 132 half- cell and 72-cell / 144 half-cell MPPT voltage range V 27 – 37 27 – 45 Operating range V 16 – 48 16 – 58 Min. / Max. start voltage V 22 / 48 22 / 58 Max. input DC voltage V 50 60 Max. continuous input DC current A 10 12 Max. input DC short-circuit current A 25 Max. module Isc A 20 Overvoltage class DC port II DC port backfeed current mA 0 PV array configuration 1 x 1 Ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA (AC)IQ8-60-2-US IQ8PLUS-72-2-US Peak output power VA 245 300 Max. continuous output power VA 240 290 Nominal (L-L) voltage / range2 V 240 / 211 – 264 Max. continuous output current A 1.0 1.21 Nominal frequency Hz 60 Extended frequency range Hz 47 – 68 AC short circuit fault current over 3 cycles Arms 2 Max. units per 20 A (L-L) branch circuit3 16 13 Total harmonic distortion <5% Overvoltage class AC port III AC port backfeed current mA 30 Power factor setting 1.0 Grid-tied power factor (adjustable)0.85 leading – 0.85 lagging Peak efficiency %97.7 CEC weighted efficiency %97 Night-time power consumption mW 60 MECHANICAL DATA Ambient temperature range -40°C to +60°C (-40°F to +140°F) Relative humidity range 4% to 100% (condensing) DC Connector type MC4 Dimensions (H x W x D)212 mm (8.3”) x 175 mm (6.9”) x 30.2 mm (1.2”) Weight 1.08 kg (2.38 lbs) Cooling Natural convection – no fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double-insulated, corrosion resistant polymeric enclosure Environ. category / UV exposure rating NEMA Type 6 / outdoor COMPLIANCE Certifications CA Rule 21 (UL 1741-SA), UL 62109-1, IEEE 1547:2018 (UL 1741-SB 3rd Ed.), FCC Part 15 Class B, ICES-0003 Class B, CAN / CSA-C22.2 NO. 107.1-01 This product is UL Listed as PV Rapid Shutdown Equipment and conforms with NEC 2014, NEC 2017, and NEC 2020 section 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according to manufacturer’s instructions. IQ8SP-12A-DS-0067-03-EN-US-2022-12-27 X-IQ-AM1-240-4 X2-IQ-AM1-240-4 (IEEE 1547:2018) The IQ Combiner 4/4C with IQ Gateway and integrated LTE-M1 cell modem (included only with IQ Combiner 4C) consolidates interconnection equipment into a single enclosure. It streamlines IQ Microinverters and storage installations by providing a consistent, pre-wired solution for residential applications. It offers up to four 2-pole input circuits and Eaton BR series busbar assembly. IQ Combiner 4/4C To learn more about Enphase offerings, visit enphase.com Data Sheet Enphase Networking Smart • Includes IQ Gateway for communication and control • Includes Mobile Connect cellular modem (CELLMODEM-M1-06-SP-05), included only with IQ Combiner 4C • Includes solar shield to match Enphase IQ Battery aesthetics and deflect heat • Supports Wi-Fi, Ethernet, or cellular connectivity • Optional AC receptacle available for PLC bridge • Provides production metering and consumption monitoring Simple • Mounts on single stud with centered brackets • Supports bottom, back and side conduit entry • Allows up to four 2-pole branch circuits for 240VAC plug-in breakers (not included) • 80A total PV or storage branch circuits Reliable • Durable NRTL-certified NEMA type 3R enclosure • Five-year limited warranty • Two years labor reimbursement program coverage included for both the IQ Combiner SKU's • UL listed • X2-IQ-AM1-240-4 and X2-IQ-AM1-240-4C comply with IEEE 1547:2018 (UL 1741-SB, 3rd Ed.) X-IQ-AM1-240-4C X2-IQ-AM1-240-4C (IEEE 1547:2018) IQ-C-4-4C-DS-0103-EN-US-12-29-2022 © 2022 Enphase Energy. All rights reserved. Enphase, the Enphase logo, IQ Combiner 4/4C, and other names are trademarks of Enphase Energy, Inc. Data subject to change. MODEL NUMBER IQ Combiner 4 X-IQ-AM1-240-4 X2-IQ-AM1-240-4 (IEEE 1547:2018) IQ Combiner 4 with IQ Gateway printed circuit board for integrated revenue grade PV production metering (ANSI C12.20 ± 0.5%) and consumption monitoring (± 2.5%). Includes a silver solar shield to match the IQ Battery and IQ System Controller 2 and to deflect heat. IQ Combiner 4C X-IQ-AM1-240-4C X2-IQ-AM1-240-4C (IEEE 1547:2018) IQ Combiner 4C with IQ Gateway printed circuit board for integrated revenue grade PV production metering (ANSI C12.20 ± 0.5%) and consumption monitoring (± 2.5%). Includes Mobile Connect cellular modem (CELLMODEM-M1-06-SP-05), a plug-and-play industrial-grade cell modem for systems up to 60 microinverters. (Available in the US, Canada, Mexico, Puerto Rico, and the US Virgin Islands, where there is adequate cellular service in the installation area.) Includes a silver solar shield to match the IQ Battery and IQ System Controller and to deflect heat. ACCESSORIES AND REPLACEMENT PARTS (not included, order separately) Supported microinverters IQ6, IQ7, and IQ8. (Do not mix IQ6/7 Microinverters with IQ8) Communications Kit COMMS-CELLMODEM-M1-06 CELLMODEM-M1-06-SP-05 CELLMODEM-M1-06-AT-05 - Includes COMMS-KIT-01 and CELLMODEM-M1-06-SP-05 with 5-year Sprint data plan - 4G based LTE-M1 cellular modem with 5-year Sprint data plan - 4G based LTE-M1 cellular modem with 5-year AT&T data plan Circuit Breakers BRK-10A-2-240V BRK-15A-2-240V BRK-20A-2P-240V BRK-15A-2P-240V-B BRK-20A-2P-240V-B Supports Eaton BR210, BR215, BR220, BR230, BR240, BR250, and BR260 circuit breakers. Circuit breaker, 2 pole, 10A, Eaton BR210 Circuit breaker, 2 pole, 15A, Eaton BR215 Circuit breaker, 2 pole, 20A, Eaton BR220 Circuit breaker, 2 pole, 15A, Eaton BR215B with hold down kit support Circuit breaker, 2 pole, 20A, Eaton BR220B with hold down kit support XA-SOLARSHIELD-ES Replacement solar shield for IQ Combiner 4/4C XA-PLUG-120-3 Accessory receptacle for Power Line Carrier in IQ Combiner 4/4C (required for EPLC-01) X-IQ-NA-HD-125A Hold-down kit for Eaton circuit breaker with screws Consumption monitoring CT (CT-200-SPLIT/CT-200-CLAMP) A pair of 200A split core current transformers ELECTRICAL SPECIFICATIONS Rating Continuous duty System voltage 120/240VAC, 60 Hz Eaton BR series busbar rating 125A Max. continuous current rating 65A Max. continuous current rating (input from PV/storage)64A Max. fuse/circuit rating (output)90A Branch circuits (solar and/or storage)Up to four 2-pole Eaton BR series Distributed Generation (DG) breakers only (not included) Max. total branch circuit breaker rating (input)80A of distributed generation/95A with IQ Gateway breaker included IQ Gateway breaker 10A or 15A rating GE/Siemens/Eaton included Production metering CT 200A solid core pre-installed and wired to IQ Gateway MECHANICAL DATA Dimensions (WxHxD)37.5 cm x 49.5 cm x 16.8 cm (14.75 in x 19.5 in x 6.63 in). Height is 53.5 cm (21.06 in) with mounting brackets. Weight 7.5 kg (16.5 lbs) Ambient temperature range -40ºC to +46ºC (-40ºF to 115ºF) Cooling Natural convection, plus heat shield Enclosure environmental rating Outdoor, NRTL-certified, NEMA type 3R, polycarbonate construction Wire sizes • 20A to 50A breaker inputs: 14 to 4 AWG copper conductors • 60A breaker branch input: 4 to 1/0 AWG copper conductors • Main lug combined output: 10 to 2/0 AWG copper conductors • Neutral and ground: 14 to 1/0 copper conductors • Always follow local code requirements for conductor sizing. Altitude Up to 3,000 meters (9,842 feet) INTERNET CONNECTION OPTIONS Integrated Wi-Fi IEEE 802.11b/g/n Cellular CELLMODEM-M1-06-SP-05, CELLMODEM-M1-06-AT-05 (4G based LTE-M1 cellular modem). Note that an Mobile Connect cellular modem is required for all Enphase Energy System installations. Ethernet Optional, IEEE 802.3, Cat5E (or Cat6) UTP Ethernet cable (not included) COMPLIANCE Compliance, IQ Combiner CA Rule 21 (UL 1741-SA) IEEE 1547:2018 - UL 1741-SB, 3rd Ed. (X2-IQ-AM1-240-4 and X2-IQ-AM1-240-4C) CAN/CSA C22.2 No. 107.1, Title 47 CFR, Part 15, Class B, ICES 003 Production metering: ANSI C12.20 accuracy class 0.5 (PV production) Consumption metering: accuracy class 2.5 Compliance, IQ Gateway UL 60601-1/CANCSA 22.2 No. 61010-1 IQ Combiner 4/4C IQ-C-4-4C-DS-0103-EN-US-12-29-2022 pe.eaton.com General Duty Cartridge Fuse Safety Switch DG223NRB UPC:782113144252 Dimensions: Height: 7 INl Length: 6.42 INl Width: 8.82 INl Weight:9 LB Notes:Maximum hp ratings apply only when dual element fuses are used. 3-Phase hp rating shown is a grounded B phase rating, UL listed. Warranties: Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first. l Specifications: Type: General Duty/Cartridge Fusel Amperage Rating: 100Al Enclosure: NEMA 3Rl Enclosure Material: Painted galvanized steell Fuse Class Provision: Class H fusesl Fuse Configuration: Fusible with neutrall Number Of Poles: Two-polel Number Of Wires: Three-wirel Product Category: General Duty Safety Switchl Voltage Rating: 240Vl Supporting documents: Eatons Volume 2-Commercial Distributionl Eaton Specification Sheet - DG223NRBl Certifications: UL Listedl Product compliance: No Data ______________________________________________________________________ © 2016 Eaton. All rights reserved. The Enphase IQ Battery 10 all-in-one AC-coupled storage system is reliable, smart, simple, and safe. It is comprised of three base IQ Battery 3 units, has a total usable energy capacity of 10.08 kWh and twelve embedded Grid-forming Microinverters with 3.84 kW power rating. It provides backup capability and installers can quickly design the right system size to meet the needs of both new and retrofit solar customers. Enphase IQ Battery 10 To learn more about Enphase offerings, visit enphase.com Data Sheet Enphase IQ Battery System Reliable • Proven high reliability IQ Series Microinverters • Ten-year limited warranty • Three independent IQ Battery base units • Twelve embedded IQ8X-BAT Microinverters • Passive cooling (no moving parts/fans) Smart • Grid-forming capability for backup operation • Remote software and firmware upgrade • Mobile app-based monitoring and control • Support for self consumption • Utility time of use (TOU) optimization Simple • Fully integrated AC battery system • Quick and easy plug-and-play installation • Interconnects with standard household AC wiring Safe • Cells safety tested • Lithium iron phosphate (LFP) chemistry for maximum safety and longevity MODEL NUMBER ENCHARGE-10-1P-NA IQ Battery 10 system with integrated Enphase IQ Microinverters and battery management unit (BMU). Includes: - Three IQ Battery 3.36 kWh base units (B03-A01-US00-1-3) - One IQ Battery 10 cover kit with cover, wall mounting bracket, watertight conduit hubs, and interconnect kit for wiring between batteries (B10-C-1050-O) ACCESSORIES ENCHARGE-HNDL-R1 One set of IQ Battery base unit installation handles OUTPUT (AC)@ 240 VAC¹ Rated (continuous) output power 3.84 kVA Peak output power 5.7 kVA (10 seconds) Nominal voltage / range 240 / 211 — 264 VAC Nominal frequency / range 60 / 57 — 61 Hz Rated output current 16 A Peak output current 24.6A (10 seconds) Power factor (adjustable)0.85 leading ... 0.85 lagging Maximum units per 20 A branch circuit 1 unit (single phase) Interconnection Single-phase Maximum AC short circuit fault current over 3 cycles 69.6 Arms 6ound trMT efficMenc]s 89% BATTERY Total capacity 10.5 kWh Usable capacity 10.08 kWh 6ound trMT efficMenc]96% Nominal DC voltage 67.2 V Maximum DC voltage 73.5 V Ambient operating temperature range -15º C to 55º C (5º F to 131º F) non-condensing Optimum operating temperature range 0º C to 30º C (32º F to 86º F) Chemistry Lithium iron phosphate (LFP) MECHANICAL DATA Dimensions (WxHxD)1070 mm x 664 mm x 319 mm (42.13 in x 26.14 in x 12.56 in) Weight Three individual 44.2 kg (97.4 lbs) base units plus 21.1 kg (48.7 lbs) cover and mounting bracket; total 154.7 kg (341 lbs) Enclosure Outdoor – NEMA type 3R IQ 8X-BAT Microinverter enclosure NEMA type 6 Cooling Natural convection – No fans Altitude Up to 2500 meters (8200 feet) Mounting Wall mount FEATURES AND COMPLIANCE Compatibility Compatible with grid-tied PV systems. Compatible with Enphase M215/M250 and IQ Series Micros, Enphase IQ System Controller, and Enphase IQ Gateway for backup operation. Communication Wireless 2.4 GHz Services Backup, self-consumption, TOU, Demand Charge, NEM Integrity Monitoring Enphase Installer Platform and Enphase App monitoring options; API integration Compliance UL 9540, UN 38.3, UL 9540A, UL 1998, UL 991, NEMA Type 3R, AC156 EMI: 47 CFR, Part 15, Class B, ICES 003 Cell Module: UL 1973, UN 38.3 Inverters: UL 62109-1, IEC 62109-2, UL 1741SA, CAN/CSA C22.2 No. 107.1-16, and IEEE 1547 LIMITED WARRANTY Limited Warranty3 >70% capacity, up to 10 years or 4000 cycles 1. Supported in backup/off grid operations 2. AC to Battery to AC at 50% power rating. . ;hMcheZer occurs first. 6estrMctMons aTTl]. Enphase IQ Battery 10 To learn more about Enphase offerings, visit enphase.com © 2021 Enphase Energy. All rights reserved. Enphase, the Enphase logo, IQ Battery 10, and other trademarks or service names are the trademarks of Enphase Energy, Inc. Data subject to change. 10-27-2021 Technical Datasheet REF: SI16-PEL64R-2-ENP Datasheet 0821Errors and omissions excepted. Subject to change without notice. © 2021 IMO Precision Controls Ltd For more information visit www.imopc.com Enphase P/N: EP200G-NA-02-RSD IMO P/N: SI16-PEL64R-2-ENP Contact Resistance per pole 1.75mΩ 1) Suitable at overvoltage category I to III, pollution degree 3 (standard-industry): Uimp = 8kV. 2) Suitable at overvoltage category I to III, pollution degree 2 (min. IP55): Uimp = 8kV. Key Features • Enclosed Solar Isolator • 600VDC, 16A • IP66 / NEMA 4X Protection Rating • 2 Pole, 1 String • Grey/Black Enclosure Cover & Handle Main Contacts DC Units SI16 DC-PV1 (acc. to IEC 60947-3) SI16 (acc. to UL508i) Rated Thermal Current Ithe A 16 Rated Insulation Voltage UI 1)V 1000 Rated Insulation Voltage UI 2)V 1500 Distance of Contacts (per pole)mm 8 Rated Operational Current Ie 300V A 16 16 350V A 16 16 400V A 16 16 500V A 16 16 600V A 16 16 Rated Conditional Short Circuit Current kAeff 5 Max. Fuse Size gL (gG)A 40 Mechanical Life Ops 10,000 Rated Short-time Withstand Current (1s) Icw A 800 Short Circuit Making Capacity Icw A 800 Size of Terminal Screw M4 Pz2 Cable Cross Sections (solid or stranded)mm / AWG 4 - 16 / 12-10 Tightening Torque Nm / lb.in 1.7 - 1.8 / 9 - 16 Maximum Operation Ambient Temperature °C -40 to +45 Maximum Storage Ambient Temperature °C -50 to +90 Power Loss at Iemax (A) / W (16) / 1 Technical Data for DC UL508i Material Art. Nr. Deckel Beschriftung mit 7 CP8439-22 7 CP8439-22-IMO-ENP grau Laser 7 CP8439-11 7 CP8439-11-IMO-ENP gelb Laser für LS/M-Schalter Än d . Ta g , N a m e Än d e r u n g ei n g e f ü h r t m i t Ä M 1 1 6 9 9 Benedict GmbH Stk. Benennung Teil Zg.-Nr / Norm Artikel-Nr. Anmerkg / Mat. Mat. Art.-Nr. siehe oben Oberfl. Werkzeug Maschine Ersatz für x Ersatz durch x Streifenbr. Zuschnitt Art.Nr. siehe oben Vorschub St./m Gestr. L. x Gez. Ollevier 12.08.21 Maßstab Gepr. x x 1 : 1 Oberteil Gehäuse PFL LOCK belasert Sonder M65422-12 7,5 <- - - > 5< > DC-PV2  IEC/AS 60947.3 SI. Series Enphase Energy System Shutdown Switch Dimensions (mm) Material Art. Nr. Deckel Beschriftung mit 7 CP8439-22 7 CP8439-22-IMO-ENP grau Laser 7 CP8439-11 7 CP8439-11-IMO-ENP gelb Laser für LS/M-Schalter Än d . Ta g , N a m e Än d e r u n g ei n g e f ü h r t m i t Ä M 1 1 6 9 9 Benedict GmbH Stk. Benennung Teil Zg.-Nr / Norm Artikel-Nr. Anmerkg / Mat. Mat. Art.-Nr. siehe oben Oberfl. Werkzeug Maschine Ersatz für x Ersatz durch x Streifenbr. Zuschnitt Art.Nr. siehe oben Vorschub St./m Gestr. L. x Gez. Ollevier 12.08.21 Maßstab Gepr. x x 1 : 1 Oberteil Gehäuse PFL LOCK belasert Sonder M65422-12 7, 5 <- - - > 5< > DC-PV2 IEC/AS 60947.3 SI. Series Enphase Energy System Shutdown Switch The Enphase IQ System Controller 2 connects the home to grid power, the IQ Battery system, and solar PV. It provides microgrid interconnection device (MID) functionality by automatically detecting and seamlessly transitioning the home energy system from grid power to backup power in the event of a grid failure. It consolidates interconnection equipment into a single enclosure and streamlines grid independent capabilities of PV and storage installations by providing a consistent, pre-wired solution for residential applications. Enphase IQ System Controller 2 To learn more about Enphase offerings, visit enphase.com Data Sheet Enphase Energy System Reliable • Durable NEMA type 3R enclosure • Ten-year limited warranty Smart • Controls safe connectivity to the grid • Automatically detects grid outages • Provides seamless transition to backup Simple • Connects to the load or service equipment¹ side of the main load panel • Centered mounting brackets support single stud mounting • Supports conduit entry from the bottom, bottom left side, and bottom right side • Supports whole home and partial home backup and subpanel backup • Up to 200A main breaker support • Includes neutral-forming transformer for split phase 120/240V backup operation • IQ System Controller supports backward compatibility with older generation of PV microinverters (M215, M250 and S series), making it simple for home owners to upgrade their systems • Easy integration with generator from major manufacturers 1. IQ System Controller 2 is not suitable for use as service equipment in Canada. To learn more about Enphase offerings, visit enphase.com © 2021 Enphase Energy. All rights reserved. Enphase, the Enphase logo, IQ System Controller 2, and other names are the trademarks of Enphase Energy, Inc. Data subject to change. 10-20-2021 MODEL NUMBER EP200G101-M240US01 Enphase IQ System Controller 2 with neutral-forming transformer (NFT), Microgrid Interconnect Device (MID), breakers, and screws. Streamlines grid-independent capabilities of PV and battery installations. ACCESSORIES and REPLACEMENT PARTS EP200G-NA-XA-E3 Replacement IQ System Controller 2 printed circuit board EP200G-NA-HD-200A Eaton type BR circuit breaker hold-down screw kit, BRHDK125 CT-200-SPLIT 200 A split core current transformers for Generator metering (+/- 2.5%) Circuit breakers (as needed)2,3 • BRK-100A-2P-240V : Main breaker, 2 pole, 100A, 25kAIC, CSR2100 • BRK-125A-2P-240V: Main breaker, 2 pole, 125A, 25kAIC, CSR2125N • BRK-150A-2P-240V: Main breaker, 2 pole, 150A, 25kAIC, CSR2150N • BRK-175A-2P-240V: Main breaker, 2 pole, 175A, 25kAIC, CSR2175N • BRK-200A-2P-240V: Main breaker, 2 pole, 200A, 25kAIC, CSR2200N Not included, must order separately: • BRK-20A-2P-240V-B: Circuit breaker, 2 pole, 20A, 10kAIC, BR220B • BRK-30A-2P-240V: Circuit breaker, 2 pole, 30A, 10kAIC, BR230B • BRK-40A-2P-240V: Circuit breaker, 2 pole, 40A, 10kAIC, BR240B • BRK-60A-2P-240V: Circuit breaker, 2 pole, 60A, 10kAIC, BR260 • BRK-80A-2P-240V: Circuit breaker, 2 pole, 80A, 10kAIC, BR280 EP200G-HNDL-R1 IQ System Controller 2 installation handle kit (order separately) EP200G-LITKIT IQ System Controller 2 literature kit, including labels, feed-through headers, screws, filler plates, and QIG BRK-20A40A-2P-240V 2 pole, 20A/40A, 10kAIC, BQC220240 ELECTRICAL SPECIFICATIONS Assembly rating Continuous operation at 100% of its rating Nominal voltage / range (L-L)240 VAC / 100 - 310 VAC Voltage measurement accuracy ±1% V nominal (±1.2V L-N and ±2.4V L-L) Auxiliary contact for load control, excess PV control, and generator two-wire control 24V, 1A Nominal frequency / range 60 Hz / 56 - 63 Hz Frequency measurement accuracy ±0.1 Hz Maximum continuous current rating 160A Maximum input overcurrent protection device 200A Maximum output overcurrent protection device 200A Maximum overcurrent protection device rating for Generator circuit4 80A Maximum overcurrent protection device rating for storage branch circuit4 (the storage branch circuit can be replaced with PV) 80A Maximum overcurrent protection device rating for IQ8 PV combiner branch circuit4 80A Neutral Forming Transformer (NFT)• Breaker rating (pre-installed): 40A between L1 and Neutral; 40A between L2 and Neutral • Continuous rated power: 3600VA • Maximum continuous unbalance current: 30A @ 120V • Peak rated power: 8800VA for 30 seconds • Peak unbalanced current: 80A @ 120V for 30 seconds MECHANICAL DATA Dimensions (WxHxD)50cm x 91.6cm x 24.6cm (19.7 in x 36 in x 9.7 in) Weight 39.4 kg (87 lbs) Ambient temperature range -40º C to +50º C (-40º F to 122º F) Cooling Natural convection, plus heat shield Enclosure environmental rating Outdoor, NEMA type 3R, polycarbonate construction Altitude To 2500 meters (8200 feet) WIRE SIZES Connections (All lugs are rated to 90C) • Main lugs and backup load lugs • CSR breaker bottom wiring lugs • BR breakers (wire provided) • AC combiner lugs, Encharge lugs, and generator lugs • Neutral (large lugs) Cu/Al: 1 AWG – 300 KCMIL Cu/Al: 2 AWG – 300 KCMIL 6 AWG 14 AWG – 2 AWG Cu/Al: 6 AWG - 300 KCMIL Neutral and ground bars Large holes (5/16-24 UNF) Small holes (10-32 UNF) 14 AWG – 1/0 AWG 14 AWG – 6 AWG COMPLIANCE Compliance UL 1741, UL 1741 SA, UL 1741 PCS, UL1998, UL869A5, UL675, UL5085, UL50E5 CSA 22.2 No. 107.1, 47 CFR, Part 15, Class B, ICES 003, AC156. IQ System Controller 2 is approved for Use as Service Equipment in the United States5. 2. Compatible with BRHDK125 Hold-Down Kit to comply with 2017 NEC 710.15E for back-fed circuit breakers. 3. The IQ System Controller 2 is rated 22 kAIC 4. Not included. Installer must provide properly rated breaker per circuit breaker list above. 5. Sections from these standards were used during the safety evaluation and included in the UL 1741 listing. Enphase IQ System Controller 2 Flush Mount System Strength Tested All components evaluated for superior structural performance. PE Certified Pre-stamped engineering letters available in most states. Class A Fire Rating Certified to maintain the fire resistance rating of the existing roof. Design Assistant Online software makes it simple to create, share, and price projects. UL 2703 Listed System Entire system and components meet newest effective UL 2703 standard. 25-Year Warranty Products guaranteed to be free of impairing defects. Built for solar’s toughest roofs. IronRidge builds the strongest mounting system for pitched roofs in solar. Every component has been tested to the limit and proven in extreme environments. Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashings, and is also why our products are fully certified, code compliant and backed by a 25-year warranty. Datasheet © 2019 IronRidge, Inc. All rights reserved. U.S. Patents: #8,695,290; #9,819,303; #9,865,938; Others Pending. Version 1.70 XR Rails Attachments Datasheet Design Assistant Go from rough layout to fully engineered system. For free. Go to IronRidge.com/design Resources XR100 Rail The ultimate residential solar mounting rail. • · VSDQQeQJ FDSDEeOeW\ • Heavy load capability ‡ &OaDn DQG EODFg ÀQeVd Bonded Splices All rails use internal splices for seamless connections. • Self-drilling screws • Varying versions for rails • Forms secure bonding XR10 Rail $ ORZSnRÀOa iRXQWeQJ nDeO for regions with light snow. • · VSDQQeQJ FDSDEeOeW\ • Moderate load capability ‡ &OaDn DQG EODFg ÀQeVd XR1000 Rail A heavyweight mounting rail for commercial projects. • · VSDQQeQJ FDSDEeOeW\ • Extreme load capability ‡ &OaDn DQRGe]aG ÀQeVd FlashFoot2 Flash and mount XR Rails ZeWd VXSaneRn ZDWanSnRRÀQJ • Twist-on Cap eases install • Wind-driven rain tested ‡ 0eOO DQG EODFg ÀQeVd Drop-in design for rapid rail attachment. • Secure rail connections • Slot for vertical adjusting ‡ &OaDn DQG EODFg ÀQeVd Slotted L-Feet Clamps & Grounding UFOs Universal Fastening Objects bond modules to rails. • Fully assembled & lubed • Single, universal size ‡ &OaDn DQG EODFg ÀQeVd Stopper Sleeves Snap onto the UFO to turn into a bonded end clamp. • Bonds modules to rails • Sized to match modules ‡ &OaDn DQG EODFg ÀQeVd CAMO Bond modules to rails while staying completely hidden. • Universal end-cam clamp • Tool-less installation • Fully assembled 5()*,7 *iv[mÄih ;vemrmrk Earn free continuing education credits, while learning more about our systems. Go to IronRidge.com/training Bond and attach XR Rails to roof attachments. • T & Square Bolt options • Nut uses 7/16” socket • Assembled and lubricated Bonding Hardware C ONTINUING E D U C A TION REGIS T E R E D PROVI D E R Flash and mount conduit, strut, or junction boxes. • Twist-on Cap eases install • Wind-driven rain tested • Secures ¾” or 1” conduit Conduit Mount Grounding Lugs Connect arrays to equipment ground. ‡ /RZ SnRÀOa • Single tool installation • Mounts in any direction © 2021 IronRidge, Inc. WA Flush Mount System Certification Letter - 1 28357 Industrial Blvd. Hayward, CA 94545 1-800-227-9523 IronRidge.com Attn: Corey Geiger, COO, IronRidge Inc. Date: 6HSWHPEHU tK, 2021 Re: Structural Certification and Span Tables for the IronRidge Flush Mount System This letter addresses the structural performance and code compliance of IronRidge’s Flush Mount System. The contents of the letter shall be read in its entirety before applying to any project design. The Flush Mount System is a proprietary rooftop mounting system used to support photovoltaic (PV) m odules installed in portrait or landscape orientation and set parallel to the underlying roof surface. PV modules are s upported by extruded aluminum XR Rails and secured to the rails with IronRidge mounting clamps. The XR Rails are s ide mounted to a selected roof attachment with 3/8” stainless steel bonding hardware and then attached directly to the roof structure or to a stanchion that is fastened to the underlying roof structure. Assembly details of a typical Flush Mount installation and its core components are sho wn in Exhibit EX-0015. The IronRidge Flush Mount System is designed and certified to the structural requirements of the reference standards listed below, for the load conditions and configurations tabulated in the attached span tables. •ASCE/SEI 7-16 Minimum Design Loads for Buildings and Other Structures (ASCE 7-16) •2018 International Building Code (IBC-2018) •2018 Washington State Building Code •2015 A luminum Design Manual (ADM-2015) •Report SEAOC (Structural Engineer Association of California) PV2-2017 Wind Design for Solar Arrays The tables included in this letter provide the maximum allowable spans of XR Rails in the Flush Mount System for the respective loads and configurations listed, covering wind exposure categories B, C, & D, roof zones provided in ASCE 7-16 for gable & hip roof profiles, and roof slopes of 8° to 45°. The tabulated spans are applicable when the following conditions are m et: 1.Span is the distance between two adjacent roof attachment points (m easured at the center of the attachment fastener). 2.Each module shall be supported by 2 rails (2 rail system) or 3 rails (3 rail system). Spans are calculated based on 2 rail systems, and conservatively deemed acceptable for 3 rail systems. 3.The underlying roof slope, measured between the roof surface and horizontal plane, is 8º to 45º. 4.The mean roof height, defined as the average of the roof eave height and the roof ridge height measured from grade, does not exceed 30 feet. 5.A clearance from the underside of the array to the roof surface of 2” minimum shall be provided and the height of the array, the distance from the module top surface to the roof surface (defined as h 2 ), shall not exceed 10”. 6.Module length and area shall not exceed the maximum values listed on the respective span tables. 7.All Flush Mount components shall be installed in a professional workmanlike manner per IronRidge’s Flush Mount Installation Manual and other applicable standards for the general roof construction practice. © 2021 IronRidge, Inc.WA Flush Mount System Certification Letter - 4 28357 Industrial Blvd. Hayward, CA 94545 1-800-227-9523 IronRidge.com The span tables provided in this letter are certified based on the structural performance of IronRidge XR Rails only with no consideration of the structural adequacy of the chosen roof attachments, PV modules, or the underlying roof supporting members. It is the responsibility of the installer or system designer to verify the structural capacity and adequacy of the aforementioned system components in regards to the applied or resultant loads of any chosen array configuration. Sincerely, Gang Xuan, PE Senior Structural Engineer 2021.09.07 15:55:03 -07'00' © 2022 IRONRIDGE, INC. VERSION 3.4 FLUSH MOUNT INSTALLATION MANUAL - 2 RATINGS Product markings are located on the Grounding Lug bolt head. MARKINGS UL 2703 LISTeD Conforms to STD UL 2703 Standard for Safety First edition: Mounting Systems, Mounting Devices, Clamping/ Retention Devices, and Ground Lugs for Use with Flat-Plate Photovoltaic Modules and Panels • Max Overcurrent Protective Device (OCPD) Rating: 40A • Max Module Size: 30.5 ft² • Module Orientation: Portrait or Landscape • System Design Load Rating: 10 PSF downward, 5 PSF upward, 5 PSF lateral • Actual system structural capacity including spans and cantilevers are defined by PE stamped certification letters. • CAMO Specific Design Load rating: 50 PSF downward, 50 PSF upward, 15 PSF lateral Certified to CSA TIL No. A-40 Photovoltaic Module Racking Systems • Load Rating: 2400 PA [50 PSF] CLASS A SYSTeM FIRe RATING PeR UL 2703• Any Roof Slope with Module Types 1, 2, 3, 13, 19, 25 & 29. • Any module-to-roof gap is permitted, with no perimeter guarding required. This rating is applicable with any third-party attachment.• Class A rated PV systems can be installed on Class A, B, and C roofs without affecting the roof fire rating. WATeR SeAL RATINGS: • UL 441 (Flashfoot2, All Tile Hook, Knockout Tile, Flashvue, L-Mount) • TAS 100(A)-95 (Flashfoot2, All Tile Hook, Knockout Tile, Flashvue, L-Mount, Qbase) • Tested and evaluated without sealant. • Any roofing manufacturer approved sealant is allowed. Ratings applicable for roof slopes between 2:12 and 12:12 STRUCTURAL CeRTIFICATION• Designed and Certified for Compliance with the International Building Code & ASCE/SEI-7 FLORIDA PRODUCT APPROVAL #FL29843 • Conforms to TAS202, TAS100(A) • Approved for installation both inside and outside High Velocity Hurricane Zones (HVHZ) • Allowable design pressure up to +100/-100 PSF • Additional details and full list of approved components can be found Here. #5003807 8431 Murphy Drive Middleton, WI 53562 USA Telephone: 608.836.4400 Facsimile: 608.831.9279 www.intertek.com Test Verification of Conformity This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. GFT-OP-11a (24-MAR-2014) Signature: Name: Nalini Mandadi Position: Project Engineer Date: 11/14/2014 In the basis of the tests undertaken, the sample(s) of the below product have been found to comply with the requirements of the referenced specifications at the time the tests were carried out. Applicant Name & Address: IronRidge, Inc. 28357 Industrial Blvd Hayward, CA 94545 USA Product Description: Flush Mount System with XR Rails. Ratings & Principle Characteristics: Fire Class Resistance Rating: -Flush Mount (Symmetrical). Class A Fire Rated for Low Slope applications when using Type 1, 2, 3, 13, 19, 25 and 29 listed photovoltaic modules. Class A Fire Rated for Steep Slope applications with Type1, 2 and 3, listed photovoltaic modules. Tested with a 5” gap (distance between the bottom the module frame and the roof covering), per the standard this system can be installed at any gap allowed by the manufacturers installation instructions. No perimeter guarding is required. This rating is applicable with any IronRidge or 3’rd party roof anchor. Models: IronRidge Flush Mount with XR Rails Brand Name: IronRidge Flush Mount Relevant Standards: UL 2703 (Section 15.2 and 15.3) Standard for Safety Mounting Systems, Mounting Devices, Clamping/Retention Devices, and Ground Lugs for Use with Flat-Plate Photovoltaic Modules and Panels, First Edition dated Jan. 28, 2015 Referencing UL1703 Third Edition dated Nov. 18, 2014, (Section 31.2) Standard for Safety for Flat-Plate Photovoltaic Modules and Panels. Verification Issuing Office: Intertek Testing Services NA, Inc. 8431 Murphy Drive Middleton, WI 53562 Date of Tests: 08/27/2014 to 03/17/2015 Test Report Number(s): 101769343MID-001r1, 101769343MID-001a, 101915978MID-001 & 101999492MID-001ar1-cr1, 104428358MID-001 EEV Revision Summary 8/27/2020 Added type 13, 19, 25 and 29 to system, update address. This verification is part of the full test report(s) and should be read in conjunction with them. This report does not automatically imply product certification. Completed by: Chris Zimbrich Reviewed by: Chad Naggs Title: Technician I, Fire Resistance Title: Technical Team Lead, Fire Resistance Signature: Signature: Date: 08/27/2020 Date: 08/27/2020 © 2022 IRONRIDGE, INC. VERSION 3.4 FLUSH MOUNT INSTALLATION MANUAL - 21 MODULe COMPATIBILITY MAKe MODeLS 7KH)OXVK0RXQW6\VWHPPD\EHXVHGWRJURXQGDQGRUPRXQWD39PRGXOHFRPSO\LQJZLWK8/RQO\ZKHQWKHVSHFL¿FPRGXOHKDV EHHQHYDOXDWHGIRUJURXQGLQJDQGRUPRXQWLQJLQFRPSOLDQFHZLWKWKHLQFOXGHGLQVWUXFWLRQV8QOHVVRWKHUZLVHQRWHG³[[[´UHIHUVWRWKH PRGXOHSRZHUUDWLQJDQGERWKEODFNDQGVLOYHUIUDPHVDUHLQFOXGHGLQWKHFHUWL¿FDWLRQ FRAMeD MODULe LIST Adani Adani modules with 35 and 40mm frames $6;<==[[[ :KHUH;FDQEH%0RU3<FDQEHRUDQG==FDQEHEODQN3(5&%3(5&RU$%3(5& Aionrise Aionrise modules with 35 and 40mm frames $,21\\*[[[ :KHUH\\FDQEHRU Amerisolar Amerisolar modules with 35, 40 and 50 mm frames $6E<[[[= :KHUHEFDQEHRU<FDQEH03030RU3DQG=FDQEHEODQN:RU:% Aptos Solar Aptos modules with 35 and 40 mm frames DNA-yy-zzaa-xxx :KHUH\\FDQEHRU]]FDQEH0)RU%)DQGDDFDQEHRU Astronergy Solar Astronergy modules with 30, 35, 40, and 45 mm frames DD60EE\\&]][[[ :KHUH³DD´FDQEH&+RU$EEFDQEHRU³\\´FDQEHEODQNRU&FDQ030 %/  0+&0 %/ +&3+&0 '* RU0 '*7 DQG³]]´FDQEHEODQN+9)%RU)%+ ASUN ASUN modules with 35 and 40 mm frames $681[[[<<==DD :KHUH<<FDQEHRU==FDQEH0RU0+DQGDDFDQEHEODQNRU%% Auxin Auxin modules with 40 mm frames AXN6y6zAxxxB :KHUH\FDQEH0RU3]FDQEHRUDQG$FDQEH)0RU7DQG%FDQEHEODQN$ B or C Axitec Axitec Modules with 30, 35 and 40 mm frames $&[[[<DD==E :KHUH<FDQEH030%RU0+DDFDQEHEODQNRU==FDQEHRU EFDQEH6;99%;9RU0; Boviet Boviet modules with 35 and 40mm frames %90==DD<<[[[%FF :KHUH==FDQEHRUDDFDQEHRU<<LV0RU3DQG%FDQEHEODQN/RU6DQGFF FDQEHEODQN++%)+%)'*++&++&%)++&%)'*+&%)RU+&%)'* BYD BYD modules with 35 mm frames %<'[[[$<== :KHUH$FDQEH030+RU3+<FDQEH&RU.DQG==FDQEHRU Canadian Solar Canadian Solar modules with 30, 32, 35 and 40 mm frames &6E<[[[= :KHUHEFDQEHRU<FDQEH+./1389:;RU<DQG=FDQEH03063;06' P-AG, P-SD, MB-AG, PB-AG, MS-AG, or MS-SD CertainTeed CertainTeed modules with 35 and 40 frames &7[[[<==$$ :KHUH<FDQEH03RU+&==FDQEHRUDQG$$FDQEHRU CSUN Csun modules with 35 and 40 mm frames YYxxx-zzAbb :KHUH<<LV&681RU667]]LVEODQNRUDQG$LVEODQN30RU00EELVEODQN%%%% BW, or ROOF Dehui Dehui modules with 30, 35 and 40mm frames '+0<<<=[[[ :KHUH³<<<´FDQEHDQG³=´FDQEH%)RU: © 2022 IRONRIDGE, INC. VERSION 3.4 FLUSH MOUNT INSTALLATION MANUAL - 22 MODULe COMPATIBILITY Ecosolargy Ecosolargy modules with 35, 40, and 50 mm frames ECOxxxYzzA-bbD :KHUH³<´FDQEH$+6RU7³]]´FDQEHRU³$´FDQEH0RU3³EE´FDQEHRUDQG³'´FDQ be blank or B ET Solar ET Solar modules with 30, 35, 40, and 50 mm frames (7<===[[[$$ :KHUH<FDQEH3/RU0===FDQEH%+%+%+%+%+DQG$$FDQ EH*/7%7::%::%%:%*::*:%$&:%&2::&2::%&2RU%%$& Flex Flex modules with 35, 40, and 50 mm frames );6[[[<<== :KHUH³<<´FDQEH%%RU%&DQG³==´FDQEH0$$%0$$:0$%:6$$%6$$:6$&% 6$&:6$':6%$%6%$:6%&%RU6%&: *&/ *&/PRGXOHVZLWKPPDQGPPIUDPHV *&/DE<<[[[ :KHUH³D´FDQEH0RU3³E´FDQEHRUDQG³<<´FDQEH+RU'+ GigaWatt Solar Gigawatt modules with 40 mm frames GWxxxYY :KHUH³<<´FDQEHHLWKHU3%RU0% +DQVRO +DQVROPRGXOHVZLWKDQGIUDPHV +6[[[<<]] :KHUH³<<´FDQEH3%3'3(7%7'8%8'RU8(DQG³]]´FDQEH$+$1$1$1+++9 RU-+ +DQZD6RODU +DQZKD6RODUPRGXOHVZLWKDQGPPIUDPHV +6/DD3<<[[[= :KHUH³DD´FDQEHHLWKHURU³<<´FDQEH3$RU3%DQG³=´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or X +\XQGDL +\XQGDLPRGXOHVZLWKDQGPPIUDPHV +L<6[[[== :KHUH<FDQEH$'RU66FDQEH0RU6DQG==FDQEH*,+*+,.,0,0)0*3,5,5* 5* %) 5* %. 6*7,RU7* Itek Itek Modules with 40 and 50 mm frames IT-xxx-YY :KHUH³<<´FDQEHEODQN+(RU6(RU6( © 2022 IRONRIDGE, INC. VERSION 3.4 FLUSH MOUNT INSTALLATION MANUAL - 23 MODULe COMPATIBILITY JA Solar JA Solar modules with 30, 35, 40 and 45 mm frames -$\\]]EEZZ[[[DD :KHUH³\\´FDQEH030RU3³]]´FDQEHEODQN .  /  5  9  %.  )$  7*  )$ 5  / %.  / 7*  5 %.  5 7*  9 %.  %. 7* RU / %. 7* ³EE´FDQEHRUZZFDQEH ''''6666666666RU6DQG³DD´FDQEH%30% 056,6&35%%%%%%5(%% Jinko Jinko modules with 35 and 40 mm frames -.0<[[[==DD :KHUH<FDQHLWKHUEHEODQNRU6==FDQEH03RU33DQGDDFDQEHEODQN%+/ %/+/+%+%/+%/(3-%-%(3 3OXV 90;5/5/% 7/%5/95/79%-%- 3OXV 9+9/9+/9+/9+/ 790;+%'93+/79RU+/90; .\RFHUD .\RFHUD0RGXOHVZLWKPPIUDPHV .<[[[==$$ :KHUH³<´FDQEH'RU8³==´FDQEHEODQN*;RU6;DQG³$$´FDQEH/38/)8838/36/3%/)% /)%6/)%/3%$&%&)&$&%&)&8&$&%&)&8&%&)&%&0&$RU 6MPA /* /*PRGXOHVZLWKDQGPPIUDPHV /*[[[<D=EE :KHUH<FDQEH$(0146DFDQEH$RU=FDQEH&.7RU:DQGEEFDQEH$$ $%%(($:**-./199 /RQJL /RQJLPRGXOHVZLWKDQGPPIUDPHV /5D<<==[[[0 :KHUHDFDQEHRU<<FDQEHEODQNRUDQG==FDQEHEODQN%.%3+93%3( 3++%'+,%+,++3%+3+RU+,%' Mission Solar Mission Solar modules with 33, 35 and 40 mm frames <<<EE[[[==DD :KHUH<<<FDQEH06(RU7;6EEFDQEHEODQNRU$==FDQEHEODQN006(626465 6;76RUDQGDDFDQEHEODQN%%%:--6.57-6:=.7RU6 Mitsubishi Mitsubishi modules with 46 mm frames 390<<[[[== :KHUH³<<´FDQEH/(RU-(DQG³==´FDQEHHLWKHU+'+'RU)% Moltech IM and XS series modules with 40, 45, and 50 mm frames Next Energy Alliance Next Energy Alliance modules with 35 and 40mm frames \\1($[[[== ZKHUH³\\´FDQEHEODQNRU86³==´FDQEH00%RU0 Neo Solar Power Neo Solar Power modules with 35 mm frames '<[[[==DD :KHUH³<´FDQEH0RU3³==´FDQEH%$%$($($+$+$DQG³DD´FDQEHEODQN 7) 0(RU ME (TF) 3DQDVRQLF +,7 Panasonic modules with 35 and 40 mm frames 9%+1[[[<<]]$ :KHUH³<<´FDQEHHLWKHU.$5$6$RU=$³]]´FDQEHHLWKHU%%% %RUDQG³$´FDQEHEODQN(*RU1 Panasonic (EverVolt) Panasonic modules with 30 mm frames EVPVxxxA :KHUH$FDQEHEODQNRU+.RU3. Peimar Peimar modules with 40 mm frames SbxxxYzz :KHUH³E´FDQEH*0RU3³<´FDQEH0RU3DQG³]]´FDQEHEODQN %) RU )% Philadelphia Solar Philadelphia modules with 35 and 40 mm frames PS-YzzAA-xxx :KHUH<FDQEH0RU3]]FDQEHRUDQG$$FDQEHEODQN %)  +& RU +&%) Phono Solar Phono Solar modules with 35, 40, and 45 mm frames 36[[[<==$ :KHUH<FDQEH000+0+00+RU3==FDQEHRUDQG$FDQEH)788+RU7+ © 2022 IRONRIDGE, INC. VERSION 3.4 FLUSH MOUNT INSTALLATION MANUAL - 24 MODULe COMPATIBILITY Recom Recom modules with 35 and 40 mm frames RCM-xxx-6yy :KHUH³\\´FDQEH0$0%0(RU0) REC Solar REC modules with 30, 38 and 45 mm frames 5(&[[[<<== :KHUH³<<´FDQEH$$013133(3(73737307360736730RU73DQG³==´FDQ EHEODQN%ODFN%/.%/.6/9RU3XUH Renesola ReneSola modules with 35, 40 and 50 mm frames $$[[[<== :KHUH$$FDQEH630 6/3 RU-&<FDQEHEODQN)0RU6DQG==FDQEHEODQN$E$EE$EK $EKE$EY$EYE%E%EE%EK%EKE%EY%EYE'E'EERU%E Renogy Renogy Modules with 40 and 50 mm frames RNG-xxxY :KHUH³[[[´LVWKHPRGXOHSRZHUUDWLQJDQG³<´FDQEH'RU3 Risen Risen Modules with 30, 35 and 40 mm frames 560\\D[[[== :KHUH\\FDQEHRUDFDQEHRUDQG==FDQEH03RU%0'* S-Energy S-Energy modules with 35 and 40mm frames 6$%%&&<<<[[[= :KHUH³$´FDQEH&'/RU1³%%´FDQEHEODQNRU³&&´FDQEHEODQNRU³<<<´FDQ EHEODQN%'(0$(0$,0%(0%,0&(RU0&,DQG³=´FDQEH903RU3 SEG Solar SEG Solar with 30, 35 and 40 mm frames 6(*D<<[[[== :KHUHDFDQEHEODQNRU%<<FDQEHEODQN0$0%3$RU3%DQG==FDQEHEODQN%%%*%: +9:%::%0%%0$+9%0$%*%0$7%%0%7%%0%+9%0'+9%0%%* Seraphim USA Seraphim modules with 30, 35, 40 and 50 mm frames 653[[[<<<== :KHUH[[[LVWKHPRGXOHSRZHUUDWLQJDQG<<<FDQEH%0$%0'0$0%3$3%4$;;;; DQG4%;;;;==LVEODQN%%%*RU+9 Sharp Sharp modules with 35 and 40 mm frames NUYYxxx :KHUH³<<´FDQEH6$RU6& Silfab Silfab Modules with 35 and 38 mm frames 6<<=[[[$E :KHUH<<FDQEH,/6$/$6*RU/*=FDQEHEODQN03RU;$FDQEHEODQN%+01DQGE FDQEH$&*./178RU; Solaria Solaria modules with 35 and 40 mm frames 3RZHU;7[[[<== :KHUH<FDQEH5RU&DQG==FDQEH$&%'%;%<3'3/3030$&3;3=:;RU:= Solarcity (Tesla) Solarcity modules with 40 mm frames SCxxxYY :KHUH³<<´FDQEHEODQN%RU% SolarTech SolarTech modules with 40 and 42 mm frames AAA-xxxYY :KHUH$$$FDQEH3(5&%%3(5&%:+-7%%+-7%:RU678<<FDQEHEODQN3(5&RU+-7 SolarWorld AG 6RODU:RUOG6XQPRGXOH3OXV3URWHFW%LVXQ;/%LVXQ;/PD\EHIROORZHGE\PRQRSRO\GXREODFNENRU FOHDUPRGXOHVZLWKRUPPIUDPHV SW-xxx M ODULe COMPATIBILITY © 2022 IRONRIDGE, INC. VERSION 3.4 FLUSH MOUNT INSTALLATION MANUAL - 25 SolarWorld Americas 6RODU:RUOG6XQPRGXOH3OXV3URWHFW%LVXQ;/%LVXQ;/PD\EHIROORZHGE\PRQRSRO\GXREODFNENRU clear; modules with 33 mm frames SWA-xxx Sonali Sonali Modules with 40 mm frames SSxxx Stion 6WLRQ7KLQ¿OPPRGXOHVZLWKPPIUDPHV STO-xxx or STO-xxxA SunEdison 6XQ(GLVRQ0RGXOHVZLWK PPIUDPHV 6(<[[[=$%&'( :KHUH<FDQEH%)+35RU==FDQEHRU$FDQEH%&'(+,-./0RU1%FDQEH%RU :&FDQEH$RU&'FDQEHRUDQG(FDQEHRU Suniva Suniva modules with 35, 38, 40, 46, and 50 mm frames 237[[[$$%<<<= 09;[[[$$%<<<= :KHUH$$LVHLWKHURU%LVHLWKHURU<<<LVHLWKHU%RU%DQG=LVEODQN or B Sunpower Sunpower standard (G3 or G4) or InvisiMount (G5) 35, 40 and 46 mm frames 635=E[[[<< :KHUH=LVHLWKHU$(30RU;³E´FDQEHEODQNRUDQG³<<´FDQEHEODQN%/. &20&$&'$&($&%/.($&*$&%/.&$&RU%/.'$& Sunspark Sunspark modules with 40 mm frames 6<<[[[=$ :KHUH³<<´FDQEH0;RU67DQG³=´FDQEH00%00%3RU:DQG$FDQEHRU Suntech Suntech Modules with 35, 40 and 50mm frames 673[[[\]]DD :KHUH\LVEODQNRU6DQG]]FDQEH$RU$8DQGDDFDQEH9G9HP9IZ9IK:GE:GH Wd, or Wfhb Talesun Talesun modules with 30, 35 and 40mm frames 7$%\==DD[[[E :KHUH$FDQEH'RU3%FDQEHRU\FDQEHEODQN)*+,RU/==FDQEHRU DDFDQEH00 + RU3DQGEFDQEHEODQN%7RU + Tesla Tesla modules with 40 mm frames TxxxY :KHUH<FDQEH+RU6 Trina Trina Modules with 30, 35, 40 and 46mm frames 760[[[<<== :KHUH<<FDQEH'''''''('('(9'(*'(*9&'(0'(*0& '('('(*&'(;3$3&3'3'3$3&3'3(RU3(DQG ==FDQEHEODQN ,,  ,, ''666 ,, $$ $$$ ,, $ ,, $ ,, $ ,, $ ,, $ ,, $ ,, ++ ,, + ,, + ,, +& ,,  +& ,, 00 ,, 0 ,, 0& ,, URE URE modules with 35 mm frames '\=[[[DD :KHUH'FDQEH'RU)\FDQEH$RU=FDQEH.RU0DQGDDFDQEH+$+$+$(*%% E8G or E8G-BB Vikram Vikram solar modules with 40 mm frames 96\\==$$$EE :KHUH\\FDQEH030%%0+060+%%RU3%%==FDQEHRU$$$LVWKHPRGXOHSRZHU UDWLQJDQGEEFDQEHRU VSUN VSUN modules with 30, 35 and 40 mm frames VSUNxxx-YYz-aa :KHUH<<FDQEHRU]FDQEH030+3+RU%0+DQGDDFDQEHEODQN%% BW, or DG M ODULe COMPATIBILITY © 2022 IRONRIDGE, INC. VERSION 3.4 FLUSH MOUNT INSTALLATION MANUAL - 26 MAKe MODeLS FRAMeLeSS MODULe LIST Astronergy Solar Astronergy frameless modules &+603 '* [[[ Canadian Solar Canadian Solar frameless modules &6E<[[[= :KHUH³E´FDQEHRU³<´LV.38RU;DQG³=´FDQEH0)*06)*3)*0%)*RU3%)* +HOLHQH +HOLHQHIUDPHOHVVPRGXOHV <<==[[[$ :KHUH<<FDQEH==FDQEH0DQG$FDQEH*+ Jinko Jinko frameless modules -.0[[[33'9 Prism Solar Prism Solar frameless modules %=<<[[[$$$ :KHUH=FDQEHLRU1<<FDQEH6RU6DQG$$$FDQEHEODQNRU%67& Risen Risen frameless modules 560\\[[[== :KHUH³\\´FDQEHRUDQG³==´FDQEH0'*RU3'* Stion Stion frameless modules 67/[[[RU67/[[[$ Sunpreme Sunpreme frameless modules GXB-xxxYY :KHUH³<<´FDQEHEODQNRU6/ Trina Trina frameless modules TSM-xxxYY :KHUH³<<´FDQEHHLWKHU'(* ,, '(* ,, '(* ,, '(* ,, '(* ,, '(*& ,,  '(*& ,, '(* ,, 3(*3(*3(*3(*3(*RU3(* Waaree Waaree modules with 40mm frames WSyy-xxx ZKHUH³\\´FDQEHEODQN0RU0% Winaico Winaico modules with 35 and 40 mm frames :V\[[[=D :KHUH\FDQEHHLWKHU3RU7=FDQEHHLWKHU03RU0;DQGDFDQEHEODQNRU Yingli Yingli modules with 35 and 40 mm frames </[[[=\\ :KHUH=FDQEH'RU3\\FDQEHEEGEERUG =16KLQH =16KLQHPRGXOHVZLWKPPIUDPHV =;0<$$$[[[0 :KHUH<FDQEHRU$$$FDQEH1+1+1+'%1+/''6+6+'%RU 6+/'' Tech Brief Moving Flashing Forward We set out to design a flashing that checked all the boxes: fully waterproof, fast and easy to install correctly, economical, and strong enough to handle every environmental condition. FlashVue does it all. The optimized flashing design features a large viewport, for easy alignment with the pilot hole. And the GripCap and GripCap+ sit snugly in place, so the lag can be driven single-handedly. FlashVue™ GripCap & GripCap+ The 360º capable GripCap (2.74” tall) and GripCap+ (3.74” tall) can be placed in any orientation, and provide a “friction-fit” for easy installs. Push snug into the viewport, without worrying it will roll away or rotate while driving the lag. Three-Tier Water Seal, Reimagined FlashVue’s seal architecture utilizes three layers of protection. The viewport is elevated 0.30”, and provides a “friction-fit” for the GripCap. The GripCap fully covers the viewport while a sealing washer adds another layer of protection. And an EPDM washer and lag bolt “seal the deal” in the stack. Large Viewport in Flashing The large viewport makes it easy to align the flashing with the pilot hole, and drive the lag centered into the rafter. The elevated rim not only provides a sturdy dock for the GripCap or GripCap+, but increases water-shedding capabilities. ⌀ 0.75” Triple Certified to Protect the Roof™ UL 2703, 441 (27) TAS 100(A)-95 © 2020 IronRidge, Inc. All rights reserved. Visit www.ironridge.com or call 1-800-227-9523 for more information. Version 1.0 Tech Brief Solve Roof Undulations See Your Pilot Holes Also Available: GripCap+ We know roofs are not always perfectly flat. GripCap+ can help when undulations get in the way. Large Viewport in Flashing FlashVue makes pilot holes highly visible, like never before. 1o more tedious guesswork on hot roofs. ;Y\Z[LK:[YLUN[O *LY[PÄJH[PVU Attachment Loading FlashVue has been tested and rated to support  lbs of uplift and 33 lbs of lateral load. Structural Certification 'esigned and certified for compliance with the ,nternational %uilding Code ASC(S(,7. Water Seal Ratings Passed both the UL  Section 27 ´Rain Testµ and TAS 00 ´Wind 'riven Rain Testµ by ,ntertek. UL 2703 Listed System Conforms to UL 2703 mechanical and bonding reTuirements. See Flush 0ount 0anual for more info.     RES IDENTIAL ROOF-MOUNTED SOLAR PANEL AP PLICATION Community & Economic Development Depa11rncnt 3'.?. l E. 5th Street, Port Angeles, WA 9836'.?. 360.417.4817 I www.cityofpa.us I permits@cityofpa.us Project Address:--------------------------------------­ PV System Description:-------------------------------------­ Mfg. I Model# of Major Equip.:-------------------------------- OWNER INFORMATION Name: _________________________ Email: _______________ _ Mailing Address: ________________________ Phone: ___________ _ ELECTRICAL CONTRACTOR INFORMATION Company Name: _________________________ License: ___________ _ Mailing Address: Expiration Date: ________ _ Email: Phone: ___________ _ PROJECT DETAILS Per WAC 51-51-2300, if the answer to the following questions is "yes" a building permit will be issued for simple (10-15kw output) PV systems without further engineering. Section M2302.2.1 -Where solar panels are installed on roofs, the roof structure shall be deemed adequate to support the load of the rooftop if all of the following are met: YES N.Q 1.PV system is designed and proposed for a single family or detached accessory structure □ □ 2.Will the photovoltaic panels and modules and supporting structure shall be constructed of noncombustible materials or fire-retardant treated wood equivalent to that required for the roof construction. The installation □ □ shall meet the requirements of the International Fire Code as amended by WA State. PV modules are listed and labeled with a fire classification in accordance with UL 1703 3.The PV system is designed for the wind speed of the local area and will be installed per the manufacturer's □ □ specifications. 4.The ground snow load does not exceed 70 pounds per square foot. The PV system is designed for the wind □ □ speed of the local area, and will be installed per the manufacturer's specifications. 5.To tal dead load of modules, supports, mountings, raceways and all other appurtenances weigh no more than □ □ four pounds per square foot. Enter total dead load of system (lbs/ft2): 6.Supports for solar modules are installed to spread the dead load across as many roof-framing members as needed to ensure that no point load exceeds fifty (50) pounds. Modules are mounted no higher than 18"□ □ above the surface of the roofing to which they are affixed and do not exceed the highest point of the roof unless approved by the local jurisdiction. NOTE: If site inspection indicates a concern that the roof structure is not adequate to support the PV module(s), engineering may be required prior to final of the permit. Owner as defined by RCW.19.28.261: (1) Owner will occupy the structure for two years after this electrical permit is finalized. (2) Owner is required to hire an electrical contractor if above said property is for sale, rent or lease. Permit expires after six months of last inspection. After reading the above statement, I hereby certify that I am the owner of the above named property or a licensed electrical contractor. I am making the electrical installation or alteration in compliance with the electrical laws, N.E.C., RCW. Chapter 19.28, WAC. Chapter 296- 468, The City of Port Angeles Municipal Code, and Utility Specifications and PAMC 14.05.050 regarding Electrical Permit Applications. Date Print Name Signature (ID Owner D Electrical Contractor/ Administrator) [Electrical Permit Applications may be submitted to City Hall or electricalpermits@cityofpa.us] -0 CD 606 Alder St, Port Angeles, WA 98362 3609 168th St NE #3507, Arlington, WA 98223