HomeMy WebLinkAbout105 1/2 W 11th St - BuildingApplication Number . . . . . 24-00000559 Date 8/07/24 Application pin number . . . 618313 Property Address . . . . . . 105 1/2 W 11TH ST ASSESSOR PARCEL NUMBER: 06-30-00-0-3-2785-0000- Application type description ELECTRICAL ONLY Subdivision Name . . . . . . Property Use . . . . . . . . Property Zoning . . . . . . . Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc ADU ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ AMY CATTERSON OWNER 105 W 11TH ST PORT ANGELES WA 98362 (360) 460-2332 ---------------------------------------------------------------------------- Permit . . . . . . ELECTRICAL ALTER RESIDENTIAL Additional desc . . ORIGNAL APP PRIOR FEE CHANGE Permit Fee . . . . 195.00 Plan Check Fee . . .00 Issue Date . . . . 6/05/24 Valuation . . . . 0 Expiration Date . . 12/14/24 Qty Unit Charge Per Extension BASE FEE 195.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 195.00 195.00 .00 .00 Plan Check Total .00 .00 .00 .00 Grand Total 195.00 195.00 .00 .00 Application Number . . . . . 24-00000559 Date 6/05/24 Application pin number . . . 618313 Property Address . . . . . . 105 W 11TH ST ASSESSOR PARCEL NUMBER: 06-30-00-0-3-2785-0000- Application type description ELECTRICAL ONLY Subdivision Name . . . . . . Property Use . . . . . . . . Property Zoning . . . . . . . RS7 RESDNTL SINGLE FAMILY Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc ADU ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ AMY CATTERSON OWNER 105 W 11TH ST PORT ANGELES WA 98362 (360) 460-2332 ---------------------------------------------------------------------------- Permit . . . . . . ELECTRICAL ALTER RESIDENTIAL Additional desc . . ORIGNAL APP PRIOR FEE CHANGE Permit Fee . . . . 195.00 Plan Check Fee . . .00 Issue Date . . . . 6/05/24 Valuation . . . . 0 Expiration Date . . 12/02/24 Qty Unit Charge Per Extension BASE FEE 195.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 195.00 195.00 .00 .00 Plan Check Total .00 .00 .00 .00 Grand Total 195.00 195.00 .00 .00 1 - 2 SINGLE-FAMILY ELECTRICAL PERMIT APPLICATION Pub! ic \Yorks and ULili ties Department 32 l E. 5th Street. Port ;\ngeles. WJ\ 98362 300.417.47]5 ! www.cilyofjJa us I electricalpcnnitsr21/cityofpa.us Project Address:--------------------------------------­ Project Description:--------------------------------------â–¡Single-Family Residential D Duplex/ ARU Building Square footage: _______________ _ OWNER JNFORMATtON Name: ________________________ Email: ______________ _ Mailing Address: ________________________ Phone: ___________ _ ELECTRfCAL CONTRACTOR fNFORMATION Name: ___________________________ License: ___________ _ Mailing Address: ________________________ Expiration Date: ________ _ Email: Phone: ___________ _ PROJECT DETAILS Item Unit Charge Qy51ntit3£ :To1s.l (Quantity x Unit Charge) Service/Feeder 200 Amp. $120.00 $ Service/Feeder 201-400 Amp. $146.00 $ Service/Feeder 401-600 Amp. $205.00 $ Service/Feeder 601-1000 Amp. $262.00 $ Service/Feeder over 1000 Amp. $373.00 $ Branch Circuit W/ Service Feeder $5.00 $ Branch Circuit W/O Service Feeder $63.00 $ Each Additional Branch Circuit $5.00 $ Branch Circuits 1-4 $75.00 $ Temp. Service/Feeder 200 Amp. $93.00 $ Temp. Service/Feeder 201-400 Amp. $110.00 $ Temp. Service/Feeder 401-600 Amp. $149.00 $ Temp. Service/Feeder 601-1000 Amp. $168.00 $ Portal to Portal Hourly $96.00 $ Signal CircuiULimited Energy - 1 &2 DU. $64.00 $ Manufactured Home Connection $120.00 $ Ren ewable Elec. Energy: 5KVA System or less $102.00 $ Thermostat (Note: $5 for each additional) $56.00 $ First 1300 Sql;Jare Feet $120.00 $ Each Additional 500 square feet" $40.00 $ Each Outbuilding / Detached Garage $74.00 $ Each Swimming Pool/ Hot Tub $110.00 $ TOTAL $ Owner as defined by RCW.19.28.261: (1) Owner will occupy the structure for two years after this electrical permit is finalized. (2) Owner is required to hire an electrical contractor if above said property is for sale, rent or lease. Permit expires after six months of last inspection. After reading the above statement, I hereby certify that I am the owner of the above named property or a licensed electrical contractor. I am making the electrical installation or alteration in compliance with the electrical laws, N.E.C., RCW. Chapter 19.28, WAC. Chapter 296- 468, The City of Port Angeles Municipal Code, and Utility Specifications and PAMC 14.05.050 regarding Electrical Permit Applications. Date Print Name Signature (0 Owner D Electrical Contractor/ Administrator) [Electrical Permit Applications may be submitted to City Hall or electricalpermits@cityofpa.us] '"'CJ CD ELECTRICAL INSPECTION WIRING REPORT APPROVED NOT APPROVED DITCH ROUGH IN/COVER SERVICE FINAL CORRECTIONS NEEDED: 1.) Proper listed MC cable connector needed. NEC 330.6 2.) Ungrounded conductors need to be distinguishable from grounded. NEC 310.6(C) 3.) Weather-resistant type receptacles needed on exterior of building. NEC 406.9 (A) 4.) Cables need to be at least 1 ¼ from nailing surface or be protected. NEC 300.4 (D) 5.) Receptacle box for hood/microwave needs to be accessible or needs to be removed. 6.) Unlisted cable mast support needs to be removed and a listed guy wire kit needs to be installed as support for mast. NOTIFY INSPECTOR at (360) 808-2613 WHEN CORRECTIONS ARE COMPLETED WITHIN 15 DAYS DATE PERMIT # INSPECTOR 6/6/2024 24-559 TMC OWNER Amy Catterson Contractor ADDRESS 105 W 11th St ELECTRICAL INSPECTION WIRING REPORT APPROVED NOT APPROVED DITCH ROUGH IN/COVER SERVICE FINAL CORRECTIONS NEEDED: 1.) Ufer ground needs to be accessible, add mud ring for blank plate for future access. 2.) Cables need to be a 1 ¼ from nailing surface. NEC 300.4 (D) 3.) There needs to be two dedicated appliance circuits, dishwasher needs to be on its own circuit, NEC 210.52 (B)(1) NOTIFY INSPECTOR at (360) 808-2613 WHEN CORRECTIONS ARE COMPLETED WITHIN 15 DAYS DATE PERMIT # INSPECTOR 6/11/2024 24-559 TMC OWNER Amy Contractor ADDRESS 1120 W 6th St ELECTRICAL INSPECTION WIRING REPORT APPROVED NOT APPROVED DITCH ROUGH IN/COVER SERVICE FINAL CORRECTIONS NEEDED: NOTIFY INSPECTOR at (360) 808-2613 WHEN CORRECTIONS ARE COMPLETED WITHIN 15 DAYS DATE PERMIT # INSPECTOR 6/17/2024 24-559 TMC OWNER Amy Catterson Contractor ADDRESS 105 W 11th St ELECTRICAL INSPECTION WIRING REPORT APPROVED NOT APPROVED DITCH ROUGH IN / COVER SERVICE FINAL CORRECTIONS NEEDED: 1.) MC cable feeding hot water tank needs to be secured and supported. NEC 330.30 (B) 2.) Dryer circuit needs to be GFCI protected. NEC 210.8 NOTIFY INSPECTOR at (360) 808-2613 WHEN CORRECTIONS ARE COMPLETED WITHIN 15 DAYS DATE PERMIT # INSPECTOR 10/11/2024 24-559 TMC OWNER Amy Catterson Contractor ADDRESS 105 W 11th St ELECTRICAL INSPECTION WIRING REPORT APPROVED NOT APPROVED DITCH ROUGH IN / COVER SERVICE FINAL CORRECTIONS NEEDED: NOTIFY INSPECTOR at (360) 808-2613 WHEN CORRECTIONS ARE COMPLETED WITHIN 15 DAYS DATE PERMIT # INSPECTOR 10/16/2024 24-559 TMC OWNER Amy Catterson Contractor ADDRESS 105 W 11th St