HomeMy WebLinkAbout2923 Maple St - Building
.
CITY OF PORT ANGELES LIGHT DEPARTMENT
321 E. Fifth Street
Port Angeles, WA 98362
(206) 457-0411
ELECTRICAL PERMIT
PERMIT NO. .,,5'023 ~
DATE /0//3 ~
. ,
Installed By:
sJ:
o READY FOR
INSPECTION
License Number:
o WILL CALL FOR
INSPECTION
Phone:
Site Address:
Owner/Business:
Phone:
Owner/Business Address:
Sq. Ft.
ELECTRIC HEAT
o BASEBOARD KW _
o FURNACE KW _
o HEAT PUMP KW
o FAN/WALL KW _
o RESIDENTIAL
o COMMERCIAL
o NEW CONSTRUCTION
o REMODEL
'SADD/ALTER CIRCUITS
to SERVICE UPGRADE/REPAIR
o TEMPORARY SERVICE
o RISER
o OVERHEAD SERVICE
o UNDERGROUND SERVICE
VOLTAGE:
0195 0395
SERVICE SIZE
FEEDER SIZE
AMPS
AMPS
DetailslDescription:
.
W.S. No. SERVICE SIZE
CAPACITY:
o O.K. 0 NOT O.K.
ACTION REQUIRED: 0 CHANGE TRANSFORMER
o INSTALL SERVICE POLE
DATE
ENGR.
o OVERHEAD SERVICE APPROVED
o CHANGE SERVICE WIRE
o OTHER
o Ditch Inspection O.K.
o Rough-in/cover O.K.
o O.K. to connect service
.~i"~Final O.K.
..
permit/5~t 801
New Meters Date:
Installer:
.
Notify Port Angeles City Light by Stree Addr and Permit Number when ready for inspection. Work must not be covered
before inspection and O.K. for covering has been given by the electrical inspector in writing on either the Wiring Report
or on the Building Permit. PHONE 457-0411, EXT. 224. of
.----;-~ NO OCCUPANCY OR USE ESTABliSHED UNDER THIS PERMIT ". ?
I . $ ~O
Electrical Inspector
Permit Fee
WHITE - File by address
PINK - Top: Eng, Bottom, Customer
GREEN - Top: Meter Dept., Boltom: City Hall
OLYl!PIC PRINTERS INC.
PORT ANGELES HOUSING REHABILITATION PROGRAM
129 E 1st St
Port Angeles, WA 98362
/:-
Telephone #452:-2023
August 4, 1995 (revised August 22, 1995)
Final worklist specifications for:
Edmund & Dolores Jackson
2923 Maple Street
Port Angeles, WA 98362
Telephone #452-2551
ATTENTION CONTRACTORS: SubmLt all bLds to the Port Angeles
HousLng RehabL1LtatLon Program off Lee no later than FrLday,
September 7, 1995.
PROJECT A (REQUIRED HEALTH AND SAFETY REPAIRS)
Lt6'0:a-rrI""i1sJ:a 11 new ha rdwi r ed smoke al a rms wi th batte r y bac k up
throughout the house (sleeping and hallway areas)to code.
Smoke alarms to be inter-tied.
, 12T8)l t h roo mar e as: Ins tall pro per G F I pro t e c t e d c i r cui tan d
outlets to replace existing outlets.
r---Y)~tchen: Install new GFI protected circuit and outlets
near the sink to replace existing outlets.
4-)-I-n's'~re that exterior outlets have proper GFI protection.
1700 l)Clean out the wood stove chimney.
PROJECT B (COST EFFECTIVE ENERGY CONSERVATION)
0700 l)Insulate the attic area over the east (2-story) addition
to R-38.
1
~
. ..
PROJECT C (EXTERIOR DETERIORATION AND BLIGHTING)
l)Reroof the east 2-story addition with 25 year 3-tab
composition seal down shingles to match the new roofing on
the west addition. Include proper attic ventilation.
A~~en~ion con~rac~ors: Please bid. all projec~s separa~ely.
Include applicable ~ax and permi~ rees.
~
2