Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
1304 S Oak St - Building
'," '-' o.~ /er0 F~RE EtPT NUMBER CITY OF PORT ANGELES DEPARTMENT OF LIGHT APPLICATION AND ELECTRICAL PERMIT AdJo(!)('Lf PERMIT NUMBEA . ~ I f/oNt~ TOTAL FEE . (J:8C GONT. LIe. NO. TIME TO COMPLETE NO. STORIES LEGAL OCCUPANCY . ELECTRICAL PERMIT ONLY NO OCCUPANCY OR USE ESTABLISHED UNDER THIS PERMIT /304- 5 tYAK CORRECT ADDRESS IS RESPONSIBILITY OF APPLICANT '>C,(MtO, Owner's Address /70 4-' S o"f K Lf~:'l - /.I ? / Site A~dre5s PERMITS ~lTH WRONG ADDRESS~S ARE CANCELLED j Installation By (pLy' It{ j? / C F Installers Address ecT Owner Day Ph:one Installers Phone Application is hereby made f~>r Permit to install Electrical Equipme~t as follows: ______c-I... ,If- N C- e" - 0 ClI N1~re /;! e k..( -e...- Wiring Method (!oNC'U I . AMP 24QV NUMBER AMP 120V 24QV USE OF CIRCUIT NUMBER PER" 120V - 100R FEE USE OF CIRCUIT PER 100R FEE CIRCUITS CIR 10 30 CIRCUITS CIR 10 30 LIGHT SIGN LIGHt 50 VOLTS OR LESS CONvENIENCE MOTOR CONVJ:NIENCE MOTOR APPL!.1I.NCE MOTOR DISHWASHER FIRE ALARMS DISPOSAL BURGLAR ALARM RANGE MISC. OVEN WATE~ HEATER LAUNlmY DRYER REINSTALLATION LIGHT FIXTURE # FUR~/CliE SYB TOTAL FEE GAS. IL- FURNA...E ENERGY FEE ELECT~IC BASIC FEE ElECTRIC HEAT IS-; <00 TOTAL FEE ELECT~IC HEAT SIZE OF SERVICE SWITCH OR CIRCUIT BREAKER A.C. UNfT AMP PHASE FEEDER SIZE OF SERVICE ENTRANCE CONDUCTORS SERVIce I )..q 0 V 's-,OP A.W.G. , I SUB. TOTAL tjX) 0 SIZE OF GROUND SIZE OF ENTRANCE SWITCH Date App(lcation made ;),,-<6 ,19 <is.>' the N.E.C. Electrical Code. I certify t~at the work to be performed under this permit will be done by the installer and By . CON RACTOR OR OWNER (OR AUTHORIZED AGENT) Permission is hereby given to do the above described work, according to the condition h on and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinances of the City of Port Angeles. , By Ai" ~ ~~F CITY LIGHT Datepermlt.lssued~-q-...-rr PLANS~ ~ Notify Department of City Light by Street Address and Permit Number when ready for inspection. Work must not be covered or current turned on before inspection and O.K. for covering or service has been given by Inspector in Writing on Permit Placard. A.. Permits Phone: 457-0411 Ext. 158. PERMIT PLACARD MUST BE KEPT POSTED ON THE WORK - SEE OVER _ WARNING WHITE. Original CANARY - Duplicate PINK - Triplicate WHITE CARD. Inspector's Report OLYMPIC PRINTERS, INC. - c'.. . ..,. REPORT OF INSPECTOR . . " OATEOFVISIT MADE BY REMARKS . . ,. i: \ . - , , t . , , .. . - > ". . l.~'1>?'r 11 . . O.K. FOR COVERING 2-'r-Y5' (,. /11 f'" ~ O.K, TO CONNECT SERVICE h- c{~'l') ) FINAL O.K. . Z <:J II: <( :IE ~ J: I- Z W l- . I- o Z o C . Application Number . . . . . 25-00001040 Date 8/19/25 Application pin number . . . 488960 Property Address . . . . . . 1304 S OAK ST ASSESSOR PARCEL NUMBER: 06-30-00-0-3-8800-0000- Application type description ELECTRICAL ONLY Subdivision Name . . . . . . Property Use . . . . . . . . Property Zoning . . . . . . . RS7 RESDNTL SINGLE FAMILY Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc PV system ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ GEORGE IRWIN III SOLGEN POWER LLC 1304 S OAK ST 5715 BEDFORD STREET PORT ANGELES WA 983627749 PASCO WA 99301 (509) 931-1663 ---------------------------------------------------------------------------- Permit . . . . . . ELECTRICAL ALTER RESIDENTIAL Additional desc . . Permit Fee . . . . 200.80 Plan Check Fee . . .00 Issue Date . . . . 8/19/25 Valuation . . . . 0 Expiration Date . . 2/15/26 Qty Unit Charge Per Extension 2.00 5.3000 ECH EL-BRANCH CIRCUIT W/FEEDER 10.60 1.00 190.2000 ECH EL-0-200 SRV FEEDER 190.20 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 200.80 200.80 .00 .00 Plan Check Total .00 .00 .00 .00 Grand Total 200.80 200.80 .00 .00 Public Works and Utilities Department 321 E. 5th Street, Port Angeles, WA 98362 360.417.4735 | www.cityofpa.us | electricalpermits@cityofpa.us EL1-2 SF 1 - 2 SINGLE-FAMILY ELECTRICAL PERMIT APPLICATION Project Address: Project Description: □Single-Family Residential □ Duplex / ARU Building Square footage: OWNER INFORMATION Name: Email: Mailing Address: Phone: ELECTRICAL CONTRACTOR INFORMATION Name: License: Mailing Address: Expiration Date: Email: Phone: PROJECT DETAILS Unit Charge Quantity Total (Quantity x Unit Charge) $190.20 $ $216.20 $ $285.30 $ $380.40 $ $475.50 $ $5.30 $ $95.10 $ $5.30 $ $125.10 $ $95.10 $ $190.20 $ $285.30 $ $380.40 $ $95.10 $ $95.10 $ $190.20 $ $190.20 $ Item Service/Feeder 200 Amp. Service/Feeder 201-400 Amp. Service/Feeder 401-600 Amp. Service/Feeder 601-1000 Amp. Service/Feeder over 1000 Amp. Branch Circuit W/ Service Feeder Branch Circuit W/O Service Feeder Each Additional Branch Circuit Branch Circuits 1-4 Temp. Service/Feeder 200 Amp. Temp. Service/Feeder 201-400 Amp. Temp. Service/Feeder 401-600 Amp. Temp. Service/Feeder 601-1000 Amp. Portal to Portal Hourly Signal Circuit/Limited Energy - 1&2 DU. Manufactured Home Connection Renewable Elec. Energy: 5KVA System or less Thermostat (Note: $5.30 for each additional)$95.10 $ First 1300 Square Feet $190.20 $ Each Additional 500 square feet``$47.55 $ Each Outbuilding / Detached Garage $95.10 $ Each Swimming Pool / Hot Tub $190.20 $ TOTAL $ Owner as defined by RCW.19.28.261: (1) Owner will occupy the structure for two years after this electrical permit is finalized. (2) Owner is required to hire an electrical contractor if above said property is for sale, rent or lease. Permit expires after six months of last inspection. After reading the above statement, I hereby certify that I am the owner of the above named property or a licensed electrical contractor. I am making the electrical installation or alteration in compliance with the electrical laws, N.E.C., RCW. Chapter 19.28, WAC. Chapter 296- 46B, The City of Port Angeles Municipal Code, and Utility Specifications and PAMC 14.05.050 regarding Electrical Permit Applications. Date Print Name Signature (□Owner □Electrical Contractor / Administrator) Pe r m i t # : New Construction Only [Electrical Permit Applications may be submitted to City Hall or epermits@cityofpa.us or faxed to 360.417.4711] 1 192.20 10.60 2 202.8 1304 S OAK ST PORT ANGELES Washington 98362 PV roof mounted system 7.31kw DC 5.919kw AC 2,002 George Irwin 1304 S OAK ST PORT ANGELES Washington 98362 svegret@gmail.com (360) 912-1270 Purelight Power SOLGEPL830RJ 5710 N rd 68 Pasco WA 99301 01/26/2026 picseattle@purelightpower.com 206-649-9976 08-18-2025 Sarah Allen Document Ref: 7GRMI-ZAZ9M-A94NP-LML7Q Page 1 of 1 REF. NUMBER 7GRMI-ZAZ9M-A94NP-LML7Q DOCUMENT COMPLETED BY ALL PARTIES ON 18 AUG 2025 19:34:22 UTC SIGNER TIMESTAMP SIGNATURE PIC SEATTLE EMAIL PICSEATTLE@PURELIGHTPOWER.COM SENT 18 AUG 2025 19:34:22 UTC SIGNED 18 AUG 2025 19:34:22 UTC IP ADDRESS 24.216.238.42 LOCATION YAKIMA, UNITED STATES Signed with PandaDoc PAGE 1 OF 1 SOLAR PANEL CHECKLIST Community & Economic Development Department 321 E. 5th Street, Port Angeles, WA 98362 360.417.4817 | www.cityofpa.us | permits@cityofpa.us RSOL RESIDENTIAL ROOF-MOUNTED Project Address: PV System Description: Mfg. / Model # of Major Equip.: OWNER INFORMATION Name: Email: Mailing Address: Phone: ELECTRICAL CONTRACTOR INFORMATION Name: License: Mailing Address: Expiration Date: Email: Phone: PROJECT DETAILS Per WAC 51-51-2300, if the answer to the following questions is “yes” a building permit will be issued for simple (10-15kw output) PV systems without further engineering. Section M2302.2.1 – Where solar panels are installed on roofs, the roof structure shall be deemed adequate to support the load of the rooftop if all of the following are met: YES NO 1. PV system is designed and proposed for a single family or detached accessory structure 2. Will the photovoltaic panels and modules and supporting structure shall be constructed of noncombustible materials or fire-retardant treated wood equivalent to that required for the roof construction. The installation shall meet the requirements of the International Fire Code as amended by WA State. PV modules are listed and labeled with a fire classification in accordance with UL 1703 3. The PV system is designed for the wind speed of the local area and will be installed per the manufacturer’s specifications. 4. The ground snow load does not exceed 70 pounds per square foot. The PV system is designed for the wind speed of the local area, and will be installed per the manufacturer ’s specifications. 5. Total dead load of modules, supports, mountings, raceways and all other appurtenances weigh no more than four pounds per square foot. Enter total dead load of system (lbs/ft2): 6. Supports for solar modules are installed to spread the dead load across as many roof-framing members as needed to ensure that no point load exceeds fifty (50) pounds. Modules are mounted no higher than 18” above the surface of the roofing to which they are affixed and do not exceed the highest point of the roof unless approved by the local jurisdiction. NOTE: If site inspection indicates a concern that the roof structure is not adequate to support the PV module(s), engineering may be required prior to final of the permit. Owner as defined by RCW.19.28.261: (1) Owner will occupy the structure for two years after this electrical permit is finalized. (2) Owner is required to hire an electrical contractor if above said property is for sale, rent or lease. Permit expires after six months of last inspection. After reading the above statement, I hereby certify that I am the owner of the above named property or a licensed electrical contractor. I am making the electrical installation or alteration in compliance with the electrical laws, N.E.C., RCW. Chapter 19.28, WAC. Chapter 296- 46B, The City of Port Angeles Municipal Code, and Utility Specifications and PAMC 14.05.050 regarding Electrical Permit Applications. Date Print Name Signature (□Owner □Electrical Contractor / Administrator) Pe r m i t # : [Electrical Permit Applications may be submitted to City Hall or electricalpermits@cityofpa.us or faxed to 360.417.4711] 1304 S OAK ST PORT ANGELES Washington 98362 PV roof mounted system 7.31kw DC 5.919kw AC Modules:(17) SEG SOLAR SEG-430-BTD-BG 4. INVERTER: (07) HOYMILES HM-700NT (03) HOYMILES HM-350NT George Irwin svegret@gmail.com 1304 S OAK ST PORT ANGELES Washington 98362 360-912-1270 Purelight Power SOLGEPL830RG 01/26/26 5710 N rd 68 Pasco WA 99301 206-649-9976 picseattle@purelightpower.com 3 lbs 08-18-2025 Sarah Allen Document Ref: SJIET-U2RDA-H5XHC-SMTW6 Page 1 of 1 REF. NUMBER SJIET-U2RDA-H5XHC-SMTW6 DOCUMENT COMPLETED BY ALL PARTIES ON 18 AUG 2025 19:37:25 UTC SIGNER TIMESTAMP SIGNATURE PIC SEATTLE EMAIL PICSEATTLE@PURELIGHTPOWER.COM SENT 18 AUG 2025 19:37:25 UTC SIGNED 18 AUG 2025 19:37:25 UTC IP ADDRESS 24.216.238.42 LOCATION YAKIMA, UNITED STATES Signed with PandaDoc PAGE 1 OF 1 SEGSOLAR www.segsolar.com YUKON N Series 420-435Wp Module Power Output 22.28% Max EfficiencyHalf-Cell N-Type Bifacial Module Warranty Key Features USA High module conversion efficiency AE Super multi busbar technology 00 00 Superior load capacity USA based liability insurance EG Product Certification IEC61215:2016; IEC 61730:2016; UL61215; UL61730100%99.0% 98%97.4% 95.4%Additional Value From Linear Warranty IEC62804 93.4%0.4%IEC6170191.4%0.9%90%89.4%IEC62716 1.4%87.4%IEC60068 1.9%IEC61215 2.4%Fire Type (UL61730): Type 29 80% 10 15 20 25 30 Better temperature coefficient Low attenuation long warranty Higher bifacially Houston, Texas based company PID Salt Mist Ammonia Resistance Dust and Sand Hailstone ISO14001:2015; IS09001:2015; ISO45001:2018 Years PV CYCLE CE TUV CALIFORNIAENERGY COMMISSIONDEKRA IntertekGuarantee on30product material 30 Years and workmanship Years Linear power output warranty FSEC About SEG Solar Founded in 2016, SEG is a leading vertically integrated PV manufacturer headquartered in Houston, Texas, U.S., and is dedicated to delivering reliable and cost-effective solar modules to the utility, commercial and residential markets. By the end of 2023, SEG has shipped over 5 GW of solar modules worldwide. The company is expected to exceed aproduction capacity of 5.5 GW by the end of 2024.Download Datasheet SEGSOLAR YUKON N Series SEG-XXX-BTD-BG-108Cells Electrical Characteristics Module Type SEG-420-BTD-BG SEG-425-BTD-BG SEG-430-BTD-BG SEG-435-BTD-BG Front Front Back Front Front Back Front Front Back Front Front Back Maximum Power -Pmp(Wp)*420 316 336 425 320 340 430 324 344 435 328 348 Open Circuit Voltage -Voc(V)38.50 36.58 38.48 38.70 36.77 38.68 38.90 36.96 38.88 39.10 37.19 39.08 Short Circuit Current -Isc(A)13.83 11.06 11.06 13.91 11.13 11.13 13.99 11.19 11.19 14.07 11.26 11.26 Maximum Power Voltage -Vmp(V)31.90 29.99 31.88 32.10 30.21 32.08 32.30 30.41 32.28 32.50 30.63 32.48 Maximum Power Current -Imp(A)13.17 10.54 10.54 13.24 10.59 10.60 13.32 10.66 10.66 13.39 10.71 10.71 Module Efficiency(%)21.51 21.76 22.02 22.28 Power Tolerance(W)(0, +4.99) Maximum System Voltage 1500V DC Maximum Series Fuse Rating 30 A Bifaciality 80±10% STC: Irradiance 1000 W/m² module temperature 25°C AM=1.5 *Measuring tolerance: ±3% Mechanical Specifications External Dimension NOCT: Irradiance 800W/m² ambient temperature 20°C module temperature 45°C wind speed: 1m/s 1722 x 1134 x 30 mm Technical Drawing Weight Solar Cells Front Glass Back Glass Frame Junction Box Connector Type Cable Type 24.0 kg N-Type 182 x 91 mm(108 pcs) 2.0 mm AR coating semi-tempered glass 2.0 mm Semi-tempered glass Black anodized aluminium alloy IP68/3 diodes MC4 12 AWG PV Wire(UL) Portrait: 400 mm(+) / 200 mm(-) Landscape: 1200 mm(+) /1200 mm(-) or customized length Cable Length Mechanical Load(Front)5400 Pa/113 psf* Mechanical Load(Rear)2400 Pa /50 psf* *Refer to SEG installation manual for details Temperature Characteristics Packing Configuration Pmax Temperature Coefficient -0.30%/°C Container 20'GP 40'HQ 40'HQ(FOr USA Voc Temperature Coefficient -0.25%/°C Pieces per Pallet 36 36 36 Isc Temperature Coefficient +0.046%/°C Pallets per Container 6 24 22Operating Temperature -40~+85°℃ Nominal Operating Cell Temperature (NOCT) 45±2 °C Pieces per Container 216 864 792 I-V Curve 18 16 Cells temp.=25°C Incident Irrad.=1000W/m²14 14 72 12 m² 10 10 Incident Irrad.=600W/m² 8Cu r r e n t [A] Cu r r e n Incident Irrad.=200W/m² 2 10 20 30 40 50 60 Voltage[V] www.segsolar.com Incident Irrad.=1000W/m² Cells temp.=10°C Cells temp.=25°C 4 Cells temp.=55°C Cells temp.=70°02 10 20 30 40 50 Voltage[V] 1086+2 17 2 2 + 2 1134+2 30±1 Section A- *Refer to SEG installation manual for details Specifications subject to technical changes SEG_DS_EN_2024V3.2 Copyright 2024 SEG Solar hoymiles Open Energy For All Technical Specifications Model Input Data (DC) HM-600NT HM-700NT HM-800NT Commonly used module power (W)240 to 405+280 to 470+320 to 540+ Maximum input voltage (60 MPPT voltage range (V)16-60 Start-up voltage (V) Maximum input current (A) Maximum input short circuit current (A) 2x 11.5 2x12.5 2x20 Number of MPPTS Number of inputs per MPPT 1 Output Data (AC) Peak output power (VA)600 700 800 Maximum continuous output p 590 Maximum ous output current (A)2.84 3.35 Nominal output voltage/range (V)240/211-264 208/183-228 240/211-264 208/183-228 240/211-264 208/183-228 60/55-65Nominal frequency/range (Hz)' Power factor (adjustable) Total harmonic distortion Microinverter Datasheet HM-60ONT HM-700NT HM-800NT Features Description Hoymiles 2-in-1 microinverter can connect up to 2 panels at once and maximize the PV production of your installation. With a maximum DC voltage of 60 V, Hoymiles microinverter is a PV Rapid Shutdown Equipment and conforms with NEC-2017 and NEC-2020 Article 690.12 and CEC-2021 Sec 64-218. All of the three mo ted are equipped with reactive power control and e requirements of IEEE 1547, UL 1741 and CA Rule21. External antenna for strongerwit Maximum units per 10 AWG branch² Maximum units per 12 AWG branch² Efficiency CEC peak efficiency CEC weighted efficiency Nominal MPPT efficiency Nighttime power consumption (mW) Mechanical Data Ambient temperature range (°C) Dimensions (W Hx D [mm]) Weight (kg) Enclosure rating Cooling Features Communication Type of isolation Monitoring 6 0.99 default 0.8 leading... 0.8 lagging <3% 96.7% 96.5% 99.8% 40 to +65 170 x 28 Outdoor-NEMA 6 (IP67) Natural convection - No fans 기 6 01 Easy installation, just plug and play 04 Warranty 2.4 GHz Proprietary RF (Nordic) Galvanically Isolated HF Transformer S-Miles Cloud Up to 25 years 02 With Reacti Control, compliant with CA Rule 21 Compliance UL 1741, IEEE 1547, UL 1741 SA (240 Vac), UL 1741 SB, CA RuleRule 2121 (240 Vac)",AC22.2N FCC Part 15B, FCC Part 15C 05 03 Compliant with U.S. NEC-2017&NEC-2020 690.12 rapid shutdown Highgh reliability:reliabi NEMA 6 (IP67) enclosure, 6000 V surge protection PV Rapid Shutdown Conforms with NEC-2017 and NEC-2020 Article 690.12contorms with d NEC-2020 Article 690.12 and CEC-20 down of PV Systems local requiremen *2 Raferto lcal recuiremante foequirements fo 3 Hoymiles Monitoring Systemmicroinverter compl CA Rule 21 (240 Vac) and CA Rule 21 (208 Vac). Region ©2024 Hoymiles Power Electronics Inc. All rights reserved sales@hoymiles ©2024 Hoymiles Power Electronics Inc. All rights reserve hoymiles Open Energy For All Technical Specifications Model HM-300NT HM-350NT HM-400NT Input Data (DC) Commonly used module power (W)240 to 405+280 to 470+320 to 540+ Maximum input voltage (V)60 MPPT voltage range (V)16-60 Start-up voltage (V)22 Maximum input current (A)11.5 11.5 12.5 Maximum input short circuit current (A)20 Number of MPPT Number of inputs per MPPT Output Data (AC) Peak output power (VA)300 350 400 Maximum continuous output power (VA)295 349 382 Maximum continuous output current (A)1.23 1.42 1.45 1.68 1.59 1.84 Nominal output voltage/range (V)'240/211-264 208/183-228 240/211-264 208/183-228 240/211-264 208/183-228 Nominal frequency/range (Hz)60/55-65 >0.99 defaultPower factor (adjustable)0.8 leading...0.8 lagging Total harmonic distortion <3% Maximum units per 10 AWG branch²19 16 16 14 15 13 Maximum units per 12 AWG branch 13 11 11 9 10 8 Efficiency CEC peak efficiency Microinverter Datasheet HM-300NT HM-350NT HM-400NT Description Hoymiles 1-in-1 microinverter, which can be connected to one panel and used in various applications, is one of the most flexible solar solutions. With a maximum DC voltage of 60 V Hoymiles microinverter is a PV Rapid Shutdown Equipment and conforms with NEC-2017 and NEC-2020 Article 690.12 and CEC-2021 Sec 64-218. All of the three models listed are equipped with reactive power control and can meet the requirements of IEEE 1547, UL 1741 and CA Rule21. CEC weighted efficiency Nominal MPPT efficiency Nighttime power consumption (mW) Mechanical Data Ambient temperature range (°C) Dimensions (W Hx D [mm]) Weight (kg) Enclosure rating Cooling Features 01 Easy installation, just plug and play 04 External antenna for stronger communication with DTU With Reactive Power Control, compliant with CA Rule 2 05 03 Compliant with U.S. NEC-2017&NEC-2020 690.12 rapid shutdown High reliability: NEMA 6 (IP67) enclosure,6000 V surge protectio 2024 ower Electronics Inc. All rights reserved sales@hoymiles 96.7% 96.5% 99.8% <50 Features Communication Type of isolation Monitoring Warranty Compliance PV Rapid Shutdown -40 to +65 182 x 164 x 29.5 1.75 Outdoor-NEMA 6 (IP67) Natural convection - No fans 2.4 GHz Proprietary RF (Nordic) Galvanically Isolated HF Transformer S-Miles Cloud Up to 25 years UL 1741, IEEE 1547, UL 1741 SA (240 Vac), UL 1741 SB, CA Rule 21 (240 Vac)", CSA C22.2 No. 107.1-16, FCC Part 15B, FCC Part 15C Conforms with NEC-2017 and NEC-2020 Article 690.12 and CEC-2021 Sec 64-218 Rapid Shutdown of PV Systems *1 Nominal voltage/frequency range can vary depending on local requirements. *2 Refer to local requirements for exact number of microinverters per branch. *3 Hoymiles Monitoring System *4 The HM-400NT microinverter complies with both CA Rule 21 (240 Vac) and CA Rule 21 (208 Vac). ©2024 Hoymiles Power Electronics Inc. All rights reserved. PEGASUS RAIL SYSTEM One Clamp Anywhere The Multi-Clamp works as mid- or end-clamp, and fits standard 30-40mm frames. Instant Bonding The N-S Bonding Jumper bonds row to row with no tools. Lifetime Wire Management Open rail channel holds and protects wires. Clamps won't pinch wires after tightening.Bonding Structural Splice Connect rails instantly, without tools, interference or limitations. Next-Level Solar Mounting A complete system for hassle-free rooftop installation, from watertight mounts to lifetime wire management. Simplicity 1/2"socket for everything. One clamp for mid or end. No tool splicing and bonding. Easy wire management. ☑ Code Compliant UL 2703 listed LTR-AE-001-2012 listed Class A fire rating for any slope ASCE 7-16 PE Certified FL Cert of Approval FL41396 Premium Aesthetics The narrowest panel gap available. Optional Hidden End Clamps and End Caps provide a flush look on the edge of the array. Watertight for Life Secured on industry-leading Pegasus Mounts, for composite shingle and tile roofs. Backed by a 25-year warranty. Pegasus Solar Inc |506 West Ohio Avenue, Richmond, CA 94804 |www.pegasussolar.com PEGASUS RAIL SYSTEM Pegasus Rail Available in 14' and 7' lengths for easy layout and shipping. Open-channel design holds MC4 connectors, PV wire and trunk cables. Black and Mill finish Pegasus Max Rail Maximum-strength design. Meets specifications for high snow-load and hurricane zones. Black and Mill finish Splice and Max Splice Installs by hand. Works over mounts. Structurally connects and bonds rails automatically; UL2703 listed as reusable. Dovetail T-bolt Dovetail shape for extra strength. Uses 1/½" socket. Multi-Clamp Fits 30-40mm PV frames, as mid-or end-clamp. Twist-locks into position; doesn't pinch wires in rail. Bonds modules to rail; UL2703 listed as reusable Hidden End Clamp Offers premium edge appearance. Preinstalled pull-tab grips rail edge, allowing easy, one-hand installation. Tucks away for reuse. Ground Lug Holds 6 or 8 AWG wire. Mounts on top or side of rail. Assembled on MLPE Mount. UL2703 listed as reusable. N-S Bonding Jumper Installs by hand, eliminates row-to-row copper wire. UL2703 listed as reusable only with Pegasus Rail. MLPE Mount Secures and bonds most micro-inverters and optimizers to rail. Connectors and wires easily route underneath after installation. UL2703 listed as reusable. Cable Grip Secures four PV wires or two trunk cables. Stainless-steel backing provides durable grip. Eliminates sagging wires. Certifications: • UL 2703, Edition 1 • LTR-AE-001-2012 • ASCE 7-16 PE certified C SP Class A fire rating for any slope roof FL Cert of Approval FL41396 FREE PEGASUS SOLAR Design Tool 乐 Wire Clip End Cap and Max End Cap Hand operable.Fits flush to PV module and hides raw or angled cuts.Holds wires in channel. Won't slip.Hidden drain quickly clears water from rail. LOAD SPAN SNOW (psf)WIND (MPH)32"48"72"96"120" US 100 이 130 10 140 30 50 190 100 PEGASUS RAIL 120 PEGASUS MAX RAIL For reference only. Spans above are calculated using 7-16 for aa GableGable RoofRoof, Exposure Category B, 0-20deg roof angle, 30ft mean roof height with non-exposed modules. For PE certified span tables, visit www.pegasussolar.com/spans. Quickly calculate the most efficient layout, spans and materials needed to suit your job.Visit the Pegasus Customer Portal. pegasussolar.com/portal Patents pending. All rights reserved. ©2023 Pegasus Solar Inc. Pegasus Solar Inc | 506 West Ohio Avenue, Richmond, CA 94804 |www.pegasussolar.com 5 Certifications / Code Compliances / Product Identifica- Certifications and Code Compliance BONDING AND GROUNDING Conforms to UL 2703, Ed. 1 Standard for Safety First Edition: Mounting Systems, Mounting Devices, Clamping/ Retention Devices, and Ground Lugs for Use with Flat-Plate Photovoltaic Modules and Panels. Certified to LTR AE-001-2012 Photovoltaic Module Racking Systems Max Overcurrent Protective Device (OCPD) Rating: 25A Max Module Size: 24ft²; Max Frameless Module Size for Canadian LTR-AE: 19.5 ft² Module Orientation: Portrait or Landscape System Level Allowable Design Load Rating: see PE stamped certification letters defining the actual system structural capacity (see Appendix B) Ground Lug conforms to UL 467 CLASS A SYSTEM FIRE RATING PER UL2703 & UL1703 Any roof slope with Module Type 1, Type 2, Type 29, Type 30 Any module-to-roof gap; no deflectors required C SP US This rating is applicable with any third-party attachment Class A rated PV systems can be installed on Class A, B, and C roofs without affecting the roof fire rating STRUCTURAL CERTIFICATION Designed and Certified for Compliance with the International Building Code, ASCE 7-10 & ASCE 7-16 For Dual Rail installations, up to 2 PV modules per pair of 7' of rails are allowed See PE Certified Span Tables in Appendix C for load ratings and details WATER SEAL RATINGS: AC286 Comp Mount has been tested and evaluated without sealant for roof slopes between 2:12 and 12:12 Product Identification Product identification can be made by looking at the top of the Multi-Clamp: Pegasus Logo above bolt head Model Name: "PRS" Lot Code: e.g. "A20-4" UL 2703 listing: CSA Mark www.pegasussolar.com PRS PIGASUSOLAR END PANEL PRS Cus A20-4 Appendix A - Compatible PV Modules (cont.) Pegasus Rail System may be used to ground a PV module complying with UL 2703 only when the specific module has been evaluated for grounding and/or mounting in compliance with this installation manual. Unless otherwise speci- fied, "xxx" refers to the power rating of the PV module. Both black & silver frames are included in the UL2703 listing.C SP Manufacturer Model REC S-Energy SEG Silfab Sonali Solar4America SolarEver Solaria SunPower US RECxxxNP; RECxxxNP Black; RECxxxPE; RECxxxPE 72; RECxxxPE(BLK); RECxxxTP; RECxxxTP BLK; RECxxxTP2; RECxxxTP2 BLK; RECxxxTP2 BLK Q2; RECxxxTP2 BLK2; RECxxxTP2M; RECxxxTP2S 72; RECxxxAA; RECxxxAA Pure; RECxxxAA Black; RECxxxAA 72; RECxxxAA PURE-R; RECxxxNP3 Black; RECxxxNP2 Black; RECxxxNP2; RECxxxAA Pure-RX; RECxxxAA Pure 2 SNxxxM-10; SNxxxM-10(B); SNxxxM-10T; SC20-60MBE-xxxM SEG-xxx-BMA-HV; SEG-xxx-BMA-TB; SEG-xxx-BMA-BG; SEG-xxx-BMB-HV; SEG-xxx-BMA-BG; SEG-xxx-BMD-HV_; SEG-xxx-BMD-TB; SEG-xxx-BMB-BG; SEG-ххх- BMC-HV; SEG-xxx-BMC-TB; SEG-xxx-BMC-BG; SEG-xxx-BTD-BG; SEG-xxx-BTB-BG SILxxxBL; SILxxxNL; SLAxXxM; SLAxxxM; SLGxxxM; SSAxxxM; SIL-xxxNX; SIL-xxxHL; SIL-xxxNX; SIL-xxxBK; SIL-xxxHC; SIL-xxxHC+; SIL-xxxBG; SIL-xxxHN; SIL-xxxHM; SIL-520QM;; SIL-xxx-QD SS-XXXW-M60 M10 S4Axxx-72MH5BB, S4Axxx-60MH5BB; S4Axxx-108MH10BB; S4Axxx-144MH10STT; S4Axxx-108TH10BB; S4Axxx-144TH10STT SE-182*91-xxxM-108N; SE-166*83-xxxM-144 PowerXT-xxxR-AC; PowerXT-xxxR-BD; PowerXT-xxxR-BX; PowerXT-xxxR-PD; PowerXT-xxxR-PX; PowerXT-xxxR-PM; PowerXT-xxxR-PL; PowerX-xxxR SPR-Axxx-G-AC; SPR-E19-xxx; SPR-E19-xxx-D-AC; SPR-E20-xxx; SPR-E20-xxx-C-AC; SPR-E20-xxx-COM; SPR-E20-xxx-D-AC; SPR-E20-xxx-E-AC; SPR-X20-xxx-D-AC; SPR-X20-xxx-E-AC; SPR-X21-xxx; SPR-X21-xxx-BLK; SPR-X21-xxx-BLK-C-AC; SPR-X21-xxx-BLK-D-AC; SPR-X21-xxx-BLK-E-AC; SPR-X21-xxx-C-AC; SPR-X21-xxx-D-AC; SPR-X22-xxx; SPR-X22-xxx-C-AC; SPR-X22-xxx-COM; SPR-X22-xxx-D-AC; SPR-X22-xxx-D-AC; SPR-X22-xxx-E-AC; SPR-xxxE-WHT-D; SPR-xxxNE-WHT-D; SPR-Mxxx-H- AC; SPR-Mxxx-BLK-H-AC TP6L60M; TP6L60M(H); TP7F60M; TP7F60M(H); TP7F54M; TP7F54MTalesun Tesla SC31582; SCxxx; SCxxxB1; SCxxxB2; TxxxS; TxxxH; SxxxH Trina TSM-xxxDD05A; TSM-xxxDD05A(II); TSM-xxxDD05A.05(II); TSM-xxxDD05A.08(II); TSM-xxxDD05A.18(II); TSM-xxxDD05H.05(II); TSM-xxxDD05H.08(II); TSM-xxxPA05.18; TSM-xxxPD05.05; TSM-xxxPD05.18; TSM-xxxPD14; TSM-xxxDD06M.05(II ); TSM-DD06H.08(II); TSM-DD06H.05(II); TSM-DE09C.05; TSM-DE09.05; TSM-DE09.07; TSM- DE09C.07; TSM-DE06X.05(II); TSM-DD06M.05(II); TSM-DE15V(II); TSM-DE15M(II); TSM-DE15H(II); TSM-14H(II); TSM-DE09.08; TSM-NE09RC.05 United Ren. Energy D6MxxxHЗА URE Co.FAMxxxE8-BB; FAMxxxE8G-BB, FBMxxxMFG-BB; FAKxxxC8G; FAKxxxE8G; FAMxxxE7G-BB; FBMxxxMFG; FBMxxxM7G-BB Vikram VSMDH.66.xxx.05; VSMDH.72.xxx.05: VSMDH.78.xxx.05; VSMDH.72.xxx.05 VSun VSUN-xxx-108BMH; VSUNxxx-120BMH; VSUNxxx-108M-BB; VSUNxxx-144BMH-DG; VSUNxxxN-108BMH; VSUNxxxN-108MH Waaree WSMDi-xXx Winaico WSP-xxxM6 Yingli YLxxxD-30b; YLxxxP-29b ZNShine ZXM6-NHLDD144; ZXM8-SP150; ZXM8-SP120; ZXM8-SPLDD120;ZXM6-NH144; ZXM6-NH132;ZXM6-NH120; ZXM7-SPLD144; ZXM6-NHLD120; ZXM6-NHLD132; ZXM7 -SH108 24 www.pegasussolar.com PEGASUS SOLAR™ A BETTER DAY ON THE JOB COMP MOUNT Simple 3-piece design for rapid installation Encapsulating design raises the water seal 0.9" above roof deck One-piece flashing with elevated cone - No press-fits or deck-level EPDM washers to fail WATERTIGHT FOR LIFE Pegasus Solar's Comp Mount is a cost effective, high-quality option for rail installations on composition shingle roofs. Designed to last decades, the one-piece flashing with elevated cone means there is simply nothing to fail. 25-year Warranty Manufactured with advanced materials and coatings to outlast the roof itself Superior Waterproofing Tested to AC286 without sealant 0.9" elevated water seal Code Compliant Fully IBC/CBC Code Compliant Exceeds ASCE 7-10 Standards All-In-One Kit Packaging Flashings, L-feet and SS lags with bonded EPDM washers are included in each 24-pack Pegasus Solar Inc • 100 West Ohio Avenue, Richmond,CA 94804 T: 510.730.1343 www.pegasussolar.com COMP MOUNT 1. Drill pilot hole in center of rafter. 2. Optional: Apply a "U-shape" of sealant to underside of flashing and position under 2nd shingle course, cone over pilot hole. 3. Place L-Foot over cone and install lag with washer through L-Foot. 4. Drive lag to required embedment. Attach rail per rail manufacturer's instructions. 1.5"0 1.9" 3.5"3.5" 2.3"2.3" Specifications SKU PSCR-CO L-foot Type Closed Slot -9.0" 11.6"0.9" Ο 2.4" Comp Mount Install Kit PSCR-UO Open Slot SPCR-CH Closed Slot Kit Contents L-Foot, Flashing, 5/16" SS Lag w/ EPDM washer L-Foot, Flashing, 5/16" SS Lag w/ EPDM washer L-Foot, Flashing, 5/16" SS Lag w/EPDM washer, M10 Hex Bolt Black (L-foot and Flashing)Finish Roof Type Certifications Install Application Compatible Rail Flashing Material L-Foot Material Kit Quantity Boxes Per Pallet Patents Pending. All rights reserved. © 2018 Pegasus Solar Inc. Composition Shingle IBC, ASCE/SEI 7-10, AC286 Railed Systems All Painted Galvalume Plus Aluminum 24 72 Pegasus Solar Inc • 100 West Ohio Avenue, Richmond, CA 94804.T: 510.730.1343 www.pegasussolar.com APN #: 0630000388000000 AHJ: CITY OF PORT ANGELES UTILITY: CITY OF PORT ANGELES GEORGE IRWIN 1304 S OAK ST, PORT ANGELES, WA 98362 PHONE #: 3609121270 E-MAIL: SVEGRET@GMAIL.COM PROJECT NAME & ADDRESS REV DATEDESCRIPTION REVISIONS PHONE - (541) 241-6764 LIC. NO. - SOLGEPL820BE 5715 BEDFORD ST PASCO, WA 99301 SOLGEN POWER LLC SATELLITE MAP COVER PAGEPV-00 EQUIPMENT DATASHEETS ATTACHED EQUIPMENT SPECIFICATIONS ENLARGED VIEW ELECTRICAL DIAGRAM WARNING LABELS ATTACHMENT PLAN & DETAILS SHEET INDEX PV-02 PV-03 PV-04 PV-06 PV-05 VICINITY MAP SITE PLANPV-01 DIRECTORY PLACARDPV-05.1 FRAMING DETAILPV-03.1 CONTRACTOR NEW PHOTOVOLTAIC PITCHED ROOF MOUNTED SYSTEM 7.310 KW DC/5.919 KW AC/6.693 KW CEC AC 1304 S OAK ST, PORT ANGELES, WA 98362 SCOPE OF WORK 1.2.1 CONTRACTOR IS RESPONSIBLE FOR THE DESIGN AND SPECIFICATIONS OF THE GRID-TIED PHOTOVOLTAIC SYSTEM. THE CONTRACTOR WILL BE RESPONSIBLE FOR COLLECTION OF EXISTING ONSITE CONDITIONS TO DESIGN, SPECIFY, AND INSTALL THE PITCHED ROOF-MOUNTED PHOTOVOLTAIC SYSTEM DETAILED IN THIS DOCUMENT APPLICABLE CODES ALL WORK SHALL CONFORM TO THE FOLLOWING CODES: 2021 WASHINGTON STATE BUILDING CODE 2021 WASHINGTON STATE RESIDENTIAL CODE 2021 WASHINGTON STATE FIRE CODE 2023 NATIONAL ELECTRICAL CODE AS ADOPTED BY CITY OF PORT ANGELES SITE NOTES 2.1.1 A LADDER WILL BE IN PLACE FOR INSPECTION IN ACCORDANCE WITH OSHA REGULATIONS. 2.1.2 THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS A UTILITY INTERACTIVE SYSTEM WITH NO STORAGE BATTERIES. 2.1.3 THE SOLAR PV INSTALLATION WILL NOT OBSTRUCT ANY PLUMBING, MECHANICAL, OR BUILDING ROOF VENTS. 2.1.4 PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL EQUIPMENT WILL BE PROVIDED IN ACCORDANCE WITH SECTION NEC 110. 2.1.5 ROOF COVERINGS SHALL BE DESIGNED, INSTALLED, AND MAINTAINED IN ACCORDANCE WITH THIS CODE AND THE APPROVED MANUFACTURER'S INSTRUCTIONS SUCH THAT THE ROOF COVERING SERVES TO PROTECT THE BUILDING OR STRUCTURE. EQUIPMENT LOCATIONS 2.2.1 ALL EQUIPMENT SHALL MEET MINIMUM SETBACKS IN ACCORDANCE WITH NEC 110. 2.2.2 WIRING SYSTEMS INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR EXPECTED OPERATING TEMPERATURE AS SPECIFIED BY NEC 690. 2.2.3 JUNCTION AND PULL BOXES PERMITTED INSTALLED UNDER PV MODULES IN ACCORDANCE WITH NEC 690. 2.2.4 ADDITIONAL AC DISCONNECT(S) SHALL BE PROVIDED WHERE THE INVERTER IS NOT WITHIN SIGHT OF THE AC SERVICING DISCONNECT. 2.2.5 ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL IN ACCORDANCE WITH NEC APPLICABLE CODES. 2.2.6 ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR OUTDOOR USAGE WHEN APPROPRIATE. STRUCTURAL NOTES 2.3.1 RACKING SYSTEM & PV ARRAY WILL BE INSTALLED IN ACCORDANCE WITH THE CODE-COMPLIANT INSTALLATION MANUAL. TOP CLAMPS REQUIRE A DESIGNATED SPACE BETWEEN MODULES, AND RAILS MUST ALSO EXTEND A MINIMUM DISTANCE BEYOND EITHER EDGE OF THE ARRAY/SUBARRAY, IN ACCORDANCE WITH RAIL MANUFACTURER’S INSTALLATION PRACTICES. 2.3.2 JUNCTION BOX WILL BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. IF ROOF-PENETRATING TYPE, IT SHALL BE FLASHED & SEALED PER LOCAL REQUIREMENTS. STRUCTURAL NOTES (CONT.) 2.3.3 ROOFTOP PENETRATIONS FOR PV RACEWAY WILL BE COMPLETED AND SEALED W/ APPROVED CHEMICAL SEALANT PER CODE BY A LICENSED CONTRACTOR. 2.3.4 ALL PV RELATED ROOF ATTACHMENTS TO BE SPACED NO GREATER THAN THE SPAN DISTANCE SPECIFIED BY THE RACKING MANUFACTURER OR PROFESSIONAL ENGINEERING GUIDANCE. 2.3.5 WHEN POSSIBLE, ALL PV RELATED RACKING ATTACHMENTS WILL BE STAGGERED AMONGST THE ROOF FRAMING MEMBERS. WIRING & CONDUIT NOTES 2.4.1 ALL CONDUIT AND WIRE WILL BE LISTED AND APPROVED FOR THEIR PURPOSE. CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING. 2.4.2 CONDUCTORS SIZED IN ACCORDANCE WITH THE NEC 2.4.3 AC CONDUCTORS TO BE COLORED OR MARKED PER NEC 2.4.4 LISTED OR LABELED EQUIPMENT SHALL BE INSTALLED AND USED IN ACCORDANCE WITH ANY INSTRUCTIONS INCLUDED IN THE LISTING OR LABELING PER NEC GROUNDING NOTES 2.5.1 GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE, AND GROUNDING DEVICES EXPOSED TO THE ELEMENTS SHALL BE RATED FOR SUCH USE. 2.5.2 PV EQUIPMENT SHALL BE GROUNDED IN ACCORDANCE WITH NEC 690. 2.5.3 METAL PARTS OF MODULE FRAMES, MODULE RACKING, AND ENCLOSURES CONSIDERED GROUNDED IN ACCORDANCE WITH NEC 250. 2.5.4 EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED IN ACCORDANCE WITH NEC 690 AND INVERTER MANUFACTURER'S INSTALLATION PRACTICES 2.5.5 EACH MODULE WILL BE GROUNDED AS SHOWN IN MANUFACTURER DOCUMENTATION AND APPROVED BY THE AHJ. 2.5.6 THE GROUNDING CONNECTION TO A MODULE SHALL BE ARRANGED SUCH THAT THE REMOVAL OF A MODULE DOES NOT INTERRUPT A GROUNDING CONDUCTOR TO ANOTHER MODULE. 2.5.7 GROUNDING AND BONDING CONDUCTORS, IF INSULATED, SHALL BE COLORED GREEN OR MARKED GREEN IF #4 AWG OR LARGER PER NEC 250. 2.5.8 THE GROUNDING ELECTRODE SYSTEM COMPLIES WITH NEC 690 AND NEC 250. IF EXISTING SYSTEM IS INACCESSIBLE, OR INADEQUATE, A GROUNDING ELECTRODE SYSTEM PROVIDED IN ACCORDANCE WITH NEC 250, NEC 690, AND THE AHJ. 2.5.9 GROUND-FAULT DETECTION SHALL COMPLY WITH NEC 690 TO REDUCE FIRE HAZARDS DISCONNECTION AND OVERCURRENT PROTECTION NOTES 2.6.1 DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS OPENED THE CONDUCTORS REMAINING ENERGIZED ARE CONNECTED TO THE TERMINALS MARKED “LINE SIDE” (TYPICALLY THE UPPER TERMINALS). 2.6.2 DISCONNECTS TO BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BE LOCKABLE, AND BE A VISIBLE-BREAK SWITCH 2.6.3 PV SYSTEM CIRCUITS INSTALLED ON OR IN HABITABLE BUILDINGS SHALL INCLUDE A RAPID SHUTDOWN FUNCTION TO REDUCE SHOCK HAZARD FOR EMERGENCY RESPONDERS IN ACCORDANCE WITH 690. 2.6.4 ALL OCPD RATINGS AND TYPES SPECIFIED ACCORDING TO NEC 690 AND 240. 2.6.5 INVERTER ON-GRID BRANCHES SHALL BE CONNECTED TO A SINGLE BREAKER OR GROUPED FUSE DISCONNECT(S) IN ACCORDANCE WITH NEC 110. 2.6.6 IF REQUIRED BY THE AHJ, SYSTEM WILL INCLUDE ARC-FAULT CIRCUIT PROTECTION IN ACCORDANCE WITH NEC 690 AND UL1699B. INTERCONNECTION NOTES 2.7.1 LOAD SIDE INTERCONNECTION SHALL BE IN ACCORDANCE WITH NEC 705. 2.7.2 THE SUM OF THE UTILITY OCPD AND INVERTER CONTINUOUS OUTPUT MAY NOT EXCEED 120 PERCENT OF BUSBAR RATING PER NEC 705. 2.7.3 THE SUM OF 125 PERCENT OF THE POWER SOURCE(S) OUTPUT CIRCUIT CURRENT AND THE RATING OF THE OVERCURRENT DEVICE PROTECTING THE BUSBAR SHALL NOT EXCEED 120 PERCENT OF THE AMPACITY OF THE BUSBAR, PV DEDICATED BACKFEED BREAKERS MUST BE LOCATED OPPOSITE END OF THE BUS FROM THE UTILITY SOURCE OCPD IN ACCORDANCE WITH NEC 705. 2.7.4 AT MULTIPLE ELECTRIC POWER SOURCES OUTPUT COMBINER PANEL, TOTAL RATING OF ALL OVERCURRENT PROTECTION DEVICES SHALL NOT EXCEED AMPACITY OF BUSBAR. HOWEVER, THE MAIN OVERCURRENT PROTECTION DEVICE MAY BE EXCLUDED IN ACCORDANCE WITH NEC 705. 2.7.5 FEEDER TAP INTERCONNECTION (LOAD SIDE) IN ACCORDANCE WITH NEC 705. 2.7.6 SUPPLY SIDE TAP INTERCONNECTION IN ACCORDANCE WITH TO NEC 705 WITH SERVICE ENTRANCE CONDUCTORS IN ACCORDANCE WITH NEC 230. 2.7.7 BACKFEEDING BREAKER FOR ELECTRIC POWER SOURCES OUTPUT IS EXEMPT FROM ADDITIONAL FASTENING PER NEC 705. GENERAL NOTES DESIGN CRITERIA 1. ROOF PITCH:32° 2. AZIMUTH:211° 3. MODULE:(17) SEG SOLAR SEG-430-BTD-BG 4. INVERTER:(07) HOYMILES HM-700NT [240V] (03) HOYMILES HM-350NT [240V] 5. NOMINAL AMPERAGE:24.65 AMPS 6. ROOF AREA:2011 FT² 7. PV ARRAY AREA:357.39 FT² 8. PV ARRAY WEIGHT:899.47 LBS 9. ROOF SURFACE TYPE: ARCHITECTURAL SHINGLES 10. ROOF STRUCTURE:2"X6 RAFTERS @ 24" OC 11. BUILDING STORY:TWO STORY 12. SNOW LOAD:25 PSF 13. WIND SPEED: 115 MPH 14. WIND EXPOSURE: B 15. RISK CATEGORY: II PROJECT NOTES 1.1.1 THIS PHOTOVOLTAIC (PV) SYSTEM SHALL COMPLY WITH THE RELEVANT YEAR OF THE NATIONAL ELECTRIC CODE (NEC), ALL MANUFACTURER’S LISTING AND INSTALLATION INSTRUCTIONS, AND THE RELEVANT CODES AS SPECIFIED BY THE AUTHORITY HAVING JURISDICTION’S (AHJ) APPLICABLE CODES. 1.1.2 THE UTILITY INTERCONNECTION APPLICATION MUST BE APPROVED AND THE PV SYSTEM MUST BE INSPECTED PRIOR TO OPERATION 1.1.3 ALL PV SYSTEM COMPONENTS; MODULES, UTILITY-INTERACTIVE INVERTERS, AND SOURCE CIRCUIT COMBINER BOXES ARE IDENTIFIED AND LISTED FOR USE IN PHOTOVOLTAIC SYSTEMS AS REQUIRED BY NEC AND OTHER GOVERNING CODES 1.1.4 ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE. IF EXPOSED TO SUNLIGHT, IT SHALL BE UV RESISTANT. ALL PLAQUES AND SIGNAGE WILL BE INSTALLED AS REQUIRED BY THE NEC AND AHJ. SYSTEM SIZE:DC SIZE: 7.310 KW DC-(STC) AC SIZE: 5.919 KW AC CEC AC SIZE: 6.693 KW AC NEW PV SYSTEM SPECIFICATIONS PV-00 7/18/2025 SHEET TITLE DRAWN DATE DRAWN BY TSD SHEET NUMBER STRUCTURAL STAMP AHJ STAMP COVER PAGE , 32°, 32° , 211°, 211° NOTE- THE INVERTERS SHALL BE SET TO IEEE 1547 ANTI-ISLANDING GRID PROFILE Signed 7/21/2025 90 ' - 0 " 99 ' - 9 " 90 ' - 0 " 99 ' - 9 " 32 ' - 0 " 22'-6" 19 ' - 9 " 27'-10" DR I V E W A Y N APN #: 0630000388000000 AHJ: CITY OF PORT ANGELES UTILITY: CITY OF PORT ANGELES GEORGE IRWIN 1304 S OAK ST, PORT ANGELES, WA 98362 PHONE #: 3609121270 E-MAIL: SVEGRET@GMAIL.COM PROJECT NAME & ADDRESS REV DATEDESCRIPTION REVISIONS SITE PLAN SCALE:1" = 15'-0" - PROPERTY LINE - FENCE LINE LEGEND PV-01 7/18/2025 SHEET TITLE DRAWN DATE DRAWN BY TSD SHEET NUMBER STRUCTURAL STAMP AHJ STAMP PV-01 1 SITE PLAN (E) DETACHED GARAGE (E) HOUSE FR O N T O F H O U S E S O A K S T W 1 3 T H S T Signed 7/21/2025 R O O F 1 R O O F 3 R O O F 2 N APN #: 0630000388000000 AHJ: CITY OF PORT ANGELES UTILITY: CITY OF PORT ANGELES GEORGE IRWIN 1304 S OAK ST, PORT ANGELES, WA 98362 PHONE #: 3609121270 E-MAIL: SVEGRET@GMAIL.COM PROJECT NAME & ADDRESS REV DATEDESCRIPTION REVISIONS SCALE:1" = 10'-0" = FLUE / PLUMBING VENT = MECHANICAL VENT LEGEND PV-02 1 PLAN VIEW TOTAL ROOF AREA:2011 FT² TOTAL PV ARRAY AREA:357.39 FT² TOTAL % OF ROOF COVERED BY PV:17.77% NOTES: 1.ROOF ACCESS POINT SHALL NOT BE LOCATED IN AREAS THAT REQUIRE THE PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS WINDOWS OR DOORS, AND LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION IN LOCATIONS WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES OR SIGNS. 2.STRUCTURES, PATIO COVERS, AND/OR ADDITIONS BUILT WITHOUT PERMITS TO BE RESOLVED BY A SEPARATE PERMIT. 44.65" 67 . 8 0 " = STRING 1 = STRING 2 = HM-700NT (1 PER 2 MODULES) = HM-350NT (1 PER 1 MODULE) ROOF 3 ROOF 2 SLOPE - 32° AZIMUTH - 211° MODULE QTY - 05 RAFTERS - 2"X6 @ 24" O.C. ARCHITECTURAL SHINGLES ROOF 1 SLOPE - 32° AZIMUTH - 211° MODULE QTY - 05 RAFTERS - 2"X6 @ 24" O.C. ARCHITECTURAL SHINGLES SLOPE - 32° AZIMUTH - 211° MODULE QTY - 07 RAFTERS - 2"X6 @ 24" O.C. ARCHITECTURAL SHINGLES ENLARGED VIEW ENLARGED VIEW FIRE SETBACKS36 " 18 " PV-02 7/18/2025 SHEET TITLE DRAWN DATE DRAWN BY TSD SHEET NUMBER STRUCTURAL STAMP AHJ STAMPPV RAPID SHUTDOWN TO BE LOCATED WITHIN 10FT OF THE UTILITY METER (N) JUNCTION BOX NEMA 3R ROOF ACCESS POINT (E) MAIN SERVICE PANEL (INSIDE HOUSE) (E) UTILITY METER (OVERHEAD SERVICE) METER #: 09842 (N) PV RAPID SHUTDOWN VISIBLE-OPEN, LOCKABLE, LABELED AND NON-FUSED AC DISCONNECT (SQUARE D DU222RB) FR O N T O F H O U S E BA C K O F H O U S E S O A K S T W 1 3 T H S T U M A C D C BMS P (N) AC COMBINER PANEL JB Signed 7/21/2025 APN #: 0630000388000000 AHJ: CITY OF PORT ANGELES UTILITY: CITY OF PORT ANGELES GEORGE IRWIN 1304 S OAK ST, PORT ANGELES, WA 98362 PHONE #: 3609121270 E-MAIL: SVEGRET@GMAIL.COM PROJECT NAME & ADDRESS REV DATEDESCRIPTION REVISIONS ATTACHMENT PLAN & DETAILS - ATTACHMENT POINTS - RAIL - STRUCTURAL MEMBER LEGEND NOTE: 6" MAXIMUM DISTANCE FROM ROOF SURFACE TO TOP OF PV MODULES DISTRIBUTED LOAD CALCULATIONS MODULE SEG SOLAR SEG-430-BTD-BG MODULE WEIGHT 52.91 LBS MODULE DIMENSIONS (L" x W")67.80" x 44.65" TOTAL QTY. OF MODULES 17 TOTAL WEIGHT OF MODULES 899.5 LBS TYPE OF RACKING PEGASUS STANDARD RAIL TYPE OF ATTACHMENT PEGASUS COMPOSITE FLASHING KIT DISTRIBUTED WEIGHT OF RACKING 0.5 PSF TOTAL WEIGHT OF ARRAY 1078.2 LBS AREA OF MODULE 21.0 SQFT. TOTAL ARRAY AREA 357.4 SQFT. DISTRIBUTED LOAD 3.0 PSF TYPICAL ATTACHMENT PLAN (PORTRAIT) SCALE: NTSPV-03 1.0 TYPICAL ATTACHMENT PLAN (LANDSCAPE) SCALE: NTSPV-03 1.1 STRUCTURAL MEMBER @ 24" OC 4'-0" OC ATTACHMENT SPACING STRUCTURAL MEMBER @ 24" OC 4'-0" OC ATTACHMENT SPACING PV-03 7/18/2025 SHEET TITLE DRAWN DATE DRAWN BY TSD SHEET NUMBER STRUCTURAL STAMP AHJ STAMP PV MODULE SEE ENLARGED VIEW (E) STRUCTURAL MEMBER MIN. 5/16" X 4-1/2" LAG BOLT W/ EPDM WASHER INTO STRUCTURAL MEMBER PEGASUS END/MID CLAMP PEGASUS STANDARD RAIL PEGASUS COMPOSITE FLASHING KIT PEGASUS FLASHING PV MODULE (E) STRUCTURAL MEMBER Scale: NTS ATTACHMENT DETAIL PV-03 2 Scale: NTS ENLARGED VIEW PV-03 3 Signed 7/21/2025 APN #: 0630000388000000 AHJ: CITY OF PORT ANGELES UTILITY: CITY OF PORT ANGELES GEORGE IRWIN 1304 S OAK ST, PORT ANGELES, WA 98362 PHONE #: 3609121270 E-MAIL: SVEGRET@GMAIL.COM PROJECT NAME & ADDRESS REV DATEDESCRIPTION REVISIONS FRAMING DETAIL SCALE: NTSFRAMING DETAIL PV-03.1 1 ROOF 3 ROOF 2 SLOPE - 32° AZIMUTH - 211° MODULE QTY - 05 RAFTERS - 2"X6 @ 24" O.C. ARCHITECTURAL SHINGLES ROOF 1 SLOPE - 32° AZIMUTH - 211° MODULE QTY - 05 RAFTERS - 2"X6" @ 24" O.C. ARCHITECTURAL SHINGLES SLOPE - 32° AZIMUTH - 211° MODULE QTY - 07 RAFTERS - 2"X6" @ 24" O.C. ARCHITECTURAL SHINGLES PV-03.1 7/18/2025 SHEET TITLE DRAWN DATE DRAWN BY TSD SHEET NUMBER STRUCTURAL STAMP AHJ STAMP 2"X6" RAFTERS @ 24" O.C. 20 ' - 0 " ROOF #1 30 LOAD BEARING WALL 2'-5" 5.18" 15'-1 " 2'-6"PV MODULES 2"X6" RAFTERS @ 24" O.C.20 ' - 0 " ROOF #3 30" LOAD BEARING WALL 2'-6"5.18" 11'-4 " 2'-8"PV MODULES 3 2 ° 3 2 ° ROOF #2 VAULTED VAULTED 2"X6" RAFTERS @ 24" O.C. 20 ' - 0 " ROOF #1 30" LOAD BEARING WALL 2'-5" 5.18" 15'-1" 2'-6"PV MODULES 3 2 ° ROOF #1 VAULTED Signed 7/21/2025 METER #: 09842 (2) #8 AWG (1) #10 EGC (2) #8 AWG (1) #10 EGC (N) PV RAPID SHUTDOWN 60A VISIBLE, LOCKABLE, LABELED AND NON-FUSIBLE, 240V, NEMA 3R, UL LISTED (SQUARE D DU222RB) G L1 L2 G L1 L2 2 2 G (N) JUNCTION BOX 600 V, NEMA 3R UL LISTED MANUFACTURER PROVIDED TRUNK CABLE 30A/2P L2 L1 G 30A/2P L2 L1 (N) 100A DEDICATED PV COMBINER PANEL, NEMA 3R, UL LISTED, 240V #6 AWG BARE CU (4) #10 AWG 1 (1) #10 EGC SEG SOLAR SEG-430-BTD-BG 08 MODULES AND 5 MICROINVERTERS IN BRANCH CIRCUIT 2 (E) BI-DIRECTIONAL UTILITY METER 1-PHASE, 3-W, 120V/240V LOAD SIDE INTERCONNECTION AT MAIN PANEL (E) 200A/2P MAIN BREAKER, 240V L2 G M N (E) 200A MAIN SERVICE PANEL, 240V NL1 TO UTILITY GRID PV 40A/2P LINE LOAD EXISTING GROUNDING ELECTRODE SYSTEM GEC (1) HOYMILES HM-350NT [240V] MICROINVERTERS ONE UNDER EVERY MODULES SEG SOLAR SEG-430-BTD-BG (4) HOYMILES HM-700NT [240V] MICROINVERTERS ONE UNDER EVERY TWO MODULES (240V) 09 MODULES AND 5 MICROINVERTERS IN BRANCH CIRCUIT 1 (2) HOYMILES HM-350NT [240V] MICROINVERTERS ONE UNDER EVERY MODULES (3) HOYMILES HM-700NT [240V] MICROINVERTERS ONE UNDER EVERY TWO MODULES (240V)APN #: 0630000388000000 AHJ: CITY OF PORT ANGELES UTILITY: CITY OF PORT ANGELES GEORGE IRWIN 1304 S OAK ST, PORT ANGELES, WA 98362 PHONE #: 3609121270 E-MAIL: SVEGRET@GMAIL.COM PROJECT NAME & ADDRESS REV DATEDESCRIPTION REVISIONS ELECTRICAL DIAGRAMDESCRIPTIONFORMULARESULT PV OVERCURRENT PROTECTION NEC 690.9(B) TOTAL INVERTER OUTPUT CURRENT x 1.25 = 24.7A x 1.25 30.8A (SELECTED PV BREAKER = 40A) 120% RULE FOR BACKFEED BREAKER NEC 705.12 BUS BAR RATING x 1.2 - MCB RATING = MAX ALLOWABLE PV BREAKER 200A x 1.2 - 200A = 40A SELECTED PV BREAKER <= MAX ALLOWABLE PV BREAKER 40A <= 40A MINIMUM WIRE SIZES CALLED OUT. USE OF LARGER WIRE IS ACCEPTABLE. 7/8" MINIMUM CONDUIT HEIGHT ABOVE ROOF SURFACE PV-04 7/18/2025 SHEET TITLE DRAWN DATE DRAWN BY TSD SHEET NUMBER AHJ STAMP ELECTRICAL STAMP PV RAPID SHUTDOWN TO BE LOCATED WITHIN 10FT OF THE UTILITY METER WIRE ID EXPECTED WIRE TEMP (°C) TEMP DERATE (90 °C) QTY OF CURRENT CARRYING CONDUCTORS CONDUIT FILL DERATE MINIMUM CONDUIT SIZE (TBD ON SITE) WIRE GAUGE & TYPE CONDUCTOR AMPACITY @ 90°C (A) CONDUCTOR AMPACITY @ 75°C (A) REQUIRED CIRCUIT CONDUCTOR AMPACITY (A) ADJUSTED CONDUCTOR AMPACITY @ 90 °C (A) NEUTRAL CONDUCTOR SIZE & TYPE GROUND WIRE SIZE & TYPE 1 25 1.05 2 1 3/4"#10 THWN-2 40 35 16.31 42.00 NONE #10 THWN-2 2 25 1.05 2 1 3/4"#8 THWN-2 55 50 30.81 57.75 NONE #10 THWN-2 NOTE- THE INVERTERS SHALL BE SET TO IEEE 1547 ANTI-ISLANDING GRID PROFILE Signed 7/21/2025 APN #: 0630000388000000 AHJ: CITY OF PORT ANGELES UTILITY: CITY OF PORT ANGELES GEORGE IRWIN 1304 S OAK ST, PORT ANGELES, WA 98362 PHONE #: 3609121270 E-MAIL: SVEGRET@GMAIL.COM PROJECT NAME & ADDRESS REV DATEDESCRIPTION REVISIONS WARNING LABELS LABELING DIAGRAM:MAIN SERVICE PANEL (INTERCONNECTED BREAKER) UTILITY METER 5 (DIRECTORY) PV RAPID SHUTDOWN 11 8 2 9 10 6 PV-05 7/18/2025 SHEET TITLE DRAWN DATE DRAWN BY TSD SHEET NUMBER AHJ STAMP ELECTRICAL STAMP 17 1 ELECTRICAL SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION WARNING! 2 WARNING DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM ! 5 INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE WARNING! 6 ELECTRIC SHOCK HAZARD RATED AC OUTPUT CURRENT: 24.65 A NOMINAL OPERATING VOLTAGE: 240VAC ! PHOTOVOLTAIC SYSTEM AC DISCONNECT ! SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN SOLAR ELECTRIC PV PANELS TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY 8 RAPID SHUTDOWN FOR SOLAR PV SYSTEM 10 PARALLEL GENERATION ON SITE11 EMERGENCY DISCONNECT SERVICE DISCONNECT17 MAIN PHOTOVOLTAIC SYSTEM DISCONNECT9 SOLAR LOAD CENTER - IF USED TO COMBINE PV OUTPUT CIRCUITS 12 12 PHOTOVOLTAIC SYSTEM COMBINER PANEL WARNING! DO NOT ADD LOADS Signed 7/21/2025 APN #: 0630000388000000 AHJ: CITY OF PORT ANGELES UTILITY: CITY OF PORT ANGELES GEORGE IRWIN 1304 S OAK ST, PORT ANGELES, WA 98362 PHONE #: 3609121270 E-MAIL: SVEGRET@GMAIL.COM PROJECT NAME & ADDRESS REV DATEDESCRIPTION REVISIONS MULTIPLE SOURCES OF POWER. POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: CAUTION ADDRESS: 1304 S OAK ST, PORT ANGELES, WA 98362 INSTALLER CONTACT: SOLGEN POWER LLC; (541) 241-6764 DIRECTORY PLACARD AC DISCONNECTSERVICE DISCONNECT UTILITY METER DIRECTORY PLACARD: ROOF ACCESS POINT PV-05.1 7/18/2025 SHEET TITLE DRAWN DATE DRAWN BY TSD SHEET NUMBER AHJ STAMP ELECTRICAL STAMP S O A K S T FR O N T O F H O U S E W 13TH ST N Signed 7/21/2025 APN #: 0630000388000000 AHJ: CITY OF PORT ANGELES UTILITY: CITY OF PORT ANGELES GEORGE IRWIN 1304 S OAK ST, PORT ANGELES, WA 98362 PHONE #: 3609121270 E-MAIL: SVEGRET@GMAIL.COM PROJECT NAME & ADDRESS REV DATEDESCRIPTION REVISIONS EQUIPMENT SPECIFICATIONS SOLAR MODULE SPECIFICATIONS MANUFACTURER / MODEL #SEG SOLAR SEG-430-BTD-BG VMP 32.30 V IMP 13.32 A VOC 38.90 V ISC 13.99 A TEMP. COEFF. VOC -0.25 %/°C PV-06 7/18/2025 SHEET TITLE DRAWN DATE DRAWN BY TSD SHEET NUMBER AHJ STAMP ELECTRICAL STAMP MICROINVERTER SPECIFICATIONS MANUFACTURER / MODEL #HOYMILES HM-700NT INPUT POWER RANGE 280W-470W MIN/MAX START VOLTAGE 22V/60V NOMINAL AC VOLTAGE 240V MAX CONT. OUTPUT CURRENT 2.9A MAX CONT. OUTPUT POWER 696W MAX MODULES PER STRING 16 (8 MICROINVERTERS) MICROINVERTER SPECIFICATIONS MANUFACTURER / MODEL #HOYMILES HM-350NT INPUT POWER RANGE 280W-470W MIN/MAX START VOLTAGE 22V/60V NOMINAL AC VOLTAGE 240V MAX CONT. OUTPUT CURRENT 1.45A MAX CONT. OUTPUT POWER 349W MAX MODULES PER STRING 16 (16 MICROINVERTERS) Signed 7/21/2025 ELECTRICAL INSPECTION WIRING REPORT APPROVED NOT APPROVED DITCH ROUGH IN/COVER SERVICE FINAL COMMENTS: NOTIFY INSPECTOR at (360) 808-2613 WHEN CORRECTIONS ARE COMPLETED WITHIN 15 DAYS DATE PERMIT # INSPECTOR 8/25/25 25-1040 TAP OWNER CONTRACTOR Solgen PROJECT ADDRESS 1304 S Oak St