Loading...
HomeMy WebLinkAbout210 Orcas Ave - Building PREPARED 12/03/07, 10-29_35 CITY OF PORT ANGELES INSPECTION TICKET INSPECTOR JAMES LIERLY PAGE DATE 2 12/03/07 ADDRESS TENANT, NBR CONTRACTOR OWNER PARCEL . APPL NUMBER 210 ORCAS AVE KEVIN & RACHEL SCHMIDT HATHAWAY CONSTRUCTION SCHMIDT KEVIN/RACHEL 06-30-10-5-0-1912-0000- 07-00000610 RES ADDITION SUBDIV PHONE PHONE (360) 457-5627 PERMIT: BPR 00 BUILDING PERMIT - RESIDENTIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS BLRI 01 7/19/07 PB BLDG REBAR INSPECTION 7/19/07 AP 07/18/2007 10:37 AM LPANGRLE RACHEL 565-1179 REBAR 07/19/2007 03: 30 PM PBARTHOL --------------------------- BL1 01 7/19/07 PB BLDG FOUNDATION FOOTING 7/19/07 AP 07/18/2007 10.36 AM LPANGRLE RACHEL 565 -11 7 9 FOOTINGS 07/19/2007 03 30 PM PBARTHOL --------------------------- BAIR 01 10/03/07 JLL BLDG AIR SEAL 10/03/07 AP October 3, 2007 8:52 35 AM Ipangrle RON 460-5143 AIRSEAL BL3 01 10/03/07 JLL BLDG FRAMING 10/03/07 AP October 3, 2007 8:52 07 AM Ipangrle RON 460-5143 FRAMING October 3, 2007 4:29 03 PM )llerly. BLI 01 10/08/07 JLL BLDG INSULATION 10/08/07 AP October 8, 2007 8:30 34 AM Ipangrle RON 460-5143 tf INSULATION EARLIEST POSSIBLE BL99 01 12/03/07 BLDG FINAL TIME 03.00 December 3, 2007 8 40 53 AM Ipangrle RACHEL 565-1179 BLDG FINAL AFTER 2 30 PM PERMIT: ME 00 MECHANICAL PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ~~~~-~~---~;/~;/~;---~~~;-- ---~l~:1;i,;l!I:-:-:i~;-i::;i;:::::::------------~~~----------~ AFTER 2:30 PM ------------------------- --------------------------------------------------------------------- PERMIT: PL 00 PLUMBING PERMIT REQUESTED INSP COMPLETED RESULT DESCRIPTION RESULTS/COMMENTS TYF/SQ PL1 01 7/13/07 PB PLUMBING UNDER SLAB 7/13/07 AP 07/12/2007 04-35 PM LPANGRLE VINCE 565-1179 UNDER SLAB PLUMBING 07/13/2007 03 27 PM PBARTHOL --------------------------- PL2 01 9/18/07 PB PLUMBING ROUGH-IN TIME 01 00 ----------------------------------- CONTINUED ONTO NEXT PAGE ----------------------------------- PREPARED 12/03/07, 10 29 35 CITY OF PORT ANGELES INSPECTION TICKET INSPECTOR' JAMES LIERLY PAGE DATE ADDRESS TENANT, NBR CONTRACTOR OWNER PARCEL . APPL NUMBER 210 ORCAS AVE KEVIN & RACHEL SCHMIDT HATHAWAY CONSTRUCTION SCHMIDT KEVIN/RACHEL 06-30-10-5-0-1912-0000- 07-00000610 RES ADDITION SUBDIV PHONE PHONE (360) 457-5627 TYP/SQ REQUESTED COMPLETED DESCRIPTION RESULTS/COMMENTS INSP RESULT 9/18/07 AP 09/17/2007 10.34 AM LPANGRLE VINCE 461-9635 "ROUGH-IN PLUMBING PRESSURE TEST" AFTERNOON 09/18/2007 04,00 PM PBARTHOL ---------------------- PL99 01 12/03/07 ~ PLUMBING FINAL TIME, 03,00 ~~\ December 3, 2007 8,42 21 AM Ipangrle. RACHEL 565-1l79 PLUMBING FINAL AFTER 2.30 PM 3 12/03/07 -------------------------------------- COMMENTS AND NOTES -------------------------------------- ELECTRICAL PERMIT AND INSPECTION RECORD CITY OF PORT ANGELES 360-417-4735 Application Number Applicat10n pin number Property Address ASSESSOR PARCEL NUMBER Tenant nbr, name Application type description Subd1v1s1on Name Property Use Property Zoning Application valuation 07-00000610 Date 10/09/07 157010 210 ORCAS AVE 06-30-10-5-0-1912-0000- KEVIN & RACHEL SCHMIDT RES ADDITION RS7 RESDNTL SINGLE FAMILY 21740 Owner Contractor SCHMIDT KEVIN/RACHEL HATHAWAY CONSTRUCTION 2301 WEST 18TH ST 324 E 7TH STREET PORT ANGELES WA 98363 PORT ANGELES PORT ANGELES WA 98362 (360) 457-5627 Structure Information 000 000 RES ADDITION Other struct info HARD SURFACE AREA Permit Add1t1onal desc Permit pin number Sub Contractor Perm1t Fee Issue Date Exp1rat1on Date ELECTRICAL NEW RESIDENTIAL CURRENT/ 200A PNL+CIRCUITS 112011 CURRENT ELECTRICAL 75 00 10/09/07 4/06/08 CNTRG INC Plan Check Fee Valuation ~ 00 o ........ ~ Qty 1 00 Un1t Charge Per 75 0000 ECH EL-RM-0-200 1ST SRV FEEDER Extension 75.00 Special Notes and Comments The Fire Department has reviewed the project application and has no comments 06/12/2007 11 32 AM SROBERDS --The proposal will result 1n a res1dent1al add1tion 1n the RS-7 zone for total lot coverage of 24$ No land use issues anticipated San1tary sewer connect1on 1nspect1on 1S requ1red by Public works prior to back fill of ditch 24 hour advance notice is requ1red ~ ~ Other Fees STATE SURCHARGE 4 50 ~ Fee summary Charged Paid Credited Due - - -------------- ---------- ---------- ---------- ---------- permi t Fee Total 75 00 75 00 00 .00 Plan Check Total .00 00 00 .00 Other Fee Total 4 50 4 50 00 00 Grand Total 79 50 79 50 00 .00 SPECTION ELECTRICAL , TYPE DATE: RESULTS: INSPECTOR: DITCH SERVICE OUGH - IN i , , I FINAL OMMENTS: , I I I , I!P ;1iJ 4c-~ PREPARED 10/0a/07, 9 39 06 CITY OF PORT ANGELES ADDRESS TENANT, NBR CONTRACTOR OWNER PARCEL APPL NUMBER INSPECTION TICKET INSPECTOR: JAMES LIERLY PAGE DATE 14 10/0a/07 210 OR CAS AVE KEVIN & RACHEL SCHMIDT HATHAWAY CONSTRUCTION SCHMIDT KEVIN/RACHEL 06-30-10-5-0-1912-0000- 07-00000610 RES ADDITION SUBDIV C \ PHONE PHONE (360) 457-5627 PERMIT: BPR 00 BUILDING PERMIT - RESIDENTIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS BLRI 01 7/19/07 PB BLDG REBAR INSPECTION 7/19/07 AP 07/1a/2007 10 37 AM LPANGRLE RACHEL 565-1179 REBAR 07/19/2007 03 30 PM PBARTHOL --------------------------- BLl 01 7/19/07 PB BLDG FOUNDATION FOOTING 7/19/07 AP 07/1a/2007 10 36 AM LPANGRLE RACHEL 565-1179 FOOTINGS 07/19/2007 03 30 PM PBARTHOL --------------------------- BAIR 01 10/03/07 JLL BLDG AIR SEAL 10/03/07 AP October 3, 2007 52:35 AM lpangrle RON 460-5143 AIRSEAL BL3 01 10/03/07 JLL BLDG FRAMING 10/03/07 AP October 3, 2007 a 52 07 AM lpangrle RON 460-5143 FRAMING October 3, 2007 4 29 03 PM ]llerly BLI 01 10/0a/07 ff BLDG INSULATION \( October a, 2007 30 34 AM lpangrle RON 460-5143 INSULATION EARLIEST POSSIBLE -------------------------------------- COMMENTS AND NOTES ------------------------------------__ PREPARED 10/03/07, 10 10 44 CITY OF PORT ANGELES INSPECTION TICKET INSPECTOR, JAMES LIERLY PAGE DATE 14 10/03/07 ADDRESS TENANT, NBR CONTRACTOR OWNER PARCEL APPL NUMBER 210 ORCAS AVE KEVIN & RACHEL SCHMIDT HATHAWAY CONSTRUCTION SCHMIDT KEVIN/RACHEL 06-30-10-5-0-1912-0000- 07-00000610 RES ADDITION SUBDIV PHONE PHONE (360) 457-5627 PERMIT: BPR 00 BUILDING PERMIT - RESIDENTIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS BLRI 01 7/19/07 PB BLDG REBAR INSPECTION 7/19/07 AP 07/18/2007 10.37 AM LPANGRLE RACHEL 565 -11 7 9 REBAR 07/19/2007 03,30 PM PBARTHOL --------------------------- BL1 01 7/19/07 PB BLDG FOUNDATION FOOTING 7/19/07 AP 07/18/2007 10,36 AM LPANGRLE RACHEL 565-1179 FOOTINGS 07/19/2007 03 30 PM PBARTHOL --------------------------- BAIR 01 10,0(3/07 Ip- BLDG AIR SEAL October 3, 2007 8'52 35 AM 1pangr1e RON 460-5143 AIRSEAL BL3 01 10/03/07 ~ BLDG FRAMING \l October 3, 2007 8 52 07 AM 1pangrle RON 460-5143 FRAMING -------------------------------------- COMMENTS AND NOTES -------------------------------------- '':J ~ PREPARED 9/18/07, 13 20 44 CITY OF PORT ANGELES INSPECTION TICKET INSPECTOR JAMES LIERLY PAGE DATE 9 9/18/07 ADDRESS TENANT, NBR CONTRACTOR OWNER PARCEL . APPL NUMBER, 210 ORCAS AVE KEVIN & RACHEL SCHMIDT HATHAWAY CONSTRUCTION SCHMIDT KEVIN/RACHEL 06-30-10-5-0-1912-0000- 07-00000610 RES ADDITION SUBDIV PHONE PHONE (360) 457-5627 PERMIT: PL 00 PLUMBING PERMIT REQUESTED INSP TYP/SQ COMPLETED RESULT DESCRIPTION RESULTS/COMMENTS PL1 01 7/13/07 PB PLUMBING UNDER SLAB 7/13/07 AP 07/12/2007 04 35 PM LPANGRLE VINCE 565-1179 UNDER SLAB PLUMBING 07/13/2007 03 27 PM PBARTHOL -----------~--------------- PL2 01 fii- JLL PLUMBING ROUGH-IN TIME 01 00 ;YP 09/17/2007 10 34 AM LPANGRLE (0 VINCE 461- 9635 "ROUGH-IN PLUMBING PRESSURE TEST" AFTERNOON -------------------------------------- COMMENTS AND NOTES -------------------------------------- PREPARED 7/19/07, 8 34 56 CITY OF PORT ANGELES INSPECTION TICKET INSPECTOR JAMES LIERLY PAGE DATE 10 7/19/07 ADDRESS TENANT, NBR CONTRACTOR OWNER PARCEL APPL NUMBER 210 ORCAS AVE KEVIN & RACHEL SCHMIDT HATHAWAY CONSTRUCTION SCHMIDT KEVIN/RACHEL 06-30-10-5-0-1912-0000- 07-00000610 RES ADDITION SUBDIV PHONE PHONE (360) 457-5627 PERMIT: BPR 00 BUILDING PERMIT - RESIDENTIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS #L BLDG REBAR INSPECTION 07/18/2007 10 37 AM LPANGRLE RACHEL 565-1179 REBAR BLl 01 7/19/07 JLL BLDG FOUNDATION FOOTING ~ jf2 07/18/2007 10 36 AM LPANGRLE ~ RACHEL 565-1179 I FOOTINGS ----------- -------------------------- COMMENTS AND NOTES -------------------------------------- BLRI 01 7/r/07 7,/] PREPARED 7/13/07, 11,06'35 CITY OF PORT ANGELES ADDRESS TENANT, NBR CONTRACTOR OWNER PARCEL , APPL NUMBER INSPECTION TICKET INSPECTOR JAMES LIERLY 210 ORCAS AVE KEVIN & RACHEL SCHMIDT HATHAWAY CONSTRUCTION SCHMIDT KEVIN/RACHEL 06-30-10-5-0-1912-0000- 07-00000610 RES ADDITION PHONE PHONE (360) 457-5627 PERMIT: PL 00 PLUMBING PERMIT REQUESTED INSP TYP/SQ COMPLETED RESULT PL1 ~W- 01 SUBDIV DESCRIPTION RESULTS/COMMENTS PLUMBING UNDER SLAB 07/12/2007 04 35 PM LPANGRLE VINCE 565-1179 UNDER SLAB PLUMBING PAGE DATE 11 7/13/07 -------------------------------------- COMMENTS AND NOTES -------------------------------------- CITY OF PORT ANGELES DEPARTMENT OF COMMUNITY DEVELOPMENT - BUILDING DIVISION 321 EAST 5TH STREET, PORT ANGELES, W A 98362 Appllcation Number Appllcatlon pln number Property Address ASSESSOR PARCEL NUMBER. Tenant nbr, name Appllcatlon type descrlptlon Subdivlsion Name Property Use Property Zonlng . . . Applicatlon valuatlon 07-00000610 Date 6/14/07 157010 210 ORCAS AVE 06-30-10-5-0-1912-0000- KEVIN & RACHEL SCHMIDT RES ADDITION RS7 RESDNTL SINGLE FAMILY 21740 Owner Contractor SCHMIDT KEVIN/RACHEL 2301 WEST 18TH ST PORT ANGELES HATHAWAY CONSTRUCTION 324 E 7TH STREET PORT ANGELES PORT ANGELES (360) 457-5627 Structure Informatlon 000 000 RES. ADDITION Other struct info HARD SURFACE AREA WA 98363 WA 98362 Permlt Addltional desc Permlt pln number Permlt Fee Issue Date Expiration Date BUILDING PERMIT -RESIDENTIAL 220 SF. ADD BATH & OFFICE 103119 375.75 Plan Check Fee. . 6/14/07 Valuatlon 12/11/07 150.30 21740 Qty Unit Charge Per Extension 95.75 280 00 BASE FEE 20.00 14.0000 THOU BL-2001-25K (14 PER K) Permlt . . . . . Addltional desc Permit pin number Permlt Fee Issue Date Explratlon Date MECHANICAL PERMIT 103135 78.55 Plan Check Fee 6/14/07 Valuation 12/11/07 00 o Qty Unlt Charge Per Extenslon 50.00 7.25 21 30 Fijzctkd /2-'/ ':>-07 BASE FEE 1 00 7.2500 ECH ME-VENT FAN 2 00 10.6500 ECH ME-OTHER APPL N/R Permlt PLUMBING PERMIT Additional desc Permlt pln number 103127 Permlt Fee 93.00 Plan Check Fee .00 Issue Date 6/14/07 Valuation 0 Explratlon Date 12/11/07 Qty Unit Charge Per Extension BASE FEE 50.00 3.00 7 0000 ECH PL- EA.FIXTURE ON ONE TRAP 21. 00 1.00 7 0000 ECH PL- EA. INSTALL WATER PIPE 7.00 1. 00 15 0000 ECH PL- EA BLDG SEWER 15 00 ~\\ Special Notes and Comments The Fire Department has revlewed the proJect appllcation and Separate Permits are reqUired forelectncal work, SEPA, Shoreline, ESA, utilities, pnvate and public Improvements ThiS permit becomes null and void if work or construction authonzed is not commenced within 180 days, if construction or work is suspended or abandoned for a period of 180 days after the work as commenced, or If required inspections have not been requested Within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct All provisions of laws and ordinances governing this type of work will be complied with whether speCified herem or not. The granting of a permit does not presume to give authority to Violate or cancel the provisions of any state or local law regulating construction or the performance of constcuct'on ~ S~ Id!rt-/01 Signature of Contractor or AuthOrized Agent Date Signature of Owner (If owner IS bUilder) Date T IPoheleslll02_15 buIldIng pennJt IIlspeelIon reeOld05 wpd [1/4/2005] o --J \ 6" - o ~ - o IT' , o ~ \f\ ~ ~ ~ ~ ---- t J BUILDING PERMIT INSPECTION RECORD CALL 417-48]5 FOR BUILDING INSPECTIONS CALL 417-4735 FOR ELECTRICAL INSPECTJONS CALL 4] 7-4807 FOR PUBLIC WORKS UTILITIES PLE'\SE PROVIDE A JvlINIMU!v1 24 HOUR NOTICE IT IS UNLA WFUL TO COlfER, INSULATE OR CONCEAL AN1' /VORl. BEFORE INSPECTED AND ACCEPTED. POST PERMIT IN A CONSPICUOUS LOCA TJON KEEP PERMIT CARD AND APPROVED PLANS AT lOB SITE INSPECTION TYPE DATE ACCEPTED COMMENTS ! I YES. NO FOUNOA TlO~ FOOTINGS SHEAIl W A~LS 1 WALLS FOlJNDA TIG>N DRAINAGE I DOVm SPOUTS I PIERS I I I I POST HOLES (POLE BLDGS ) PLUMIlING I UNDER FLOOR 1 SLAB ROUGH-IN ! WATER UN!" (METER TO BLDG) I GAS LlNE FIN A.L DA.TE ACCEPTED BY BACK FLOW I WATER AIR SE<\L I WALLS I CEILING I FRAMING I I JOISTS 1 GIRDERS I I SHEAR WALL/HOLD DOWNS I WALLS 1 ROOF I CEILING I DRYWALL (INTERIOR BRACED PANEL ONLY) T-BAR I 1 INSULA TJON! SLAB I WALL 1 FLOOR I CEILING MECHANldL ROUGH-IN I HEAT PUMY 1 FURNACE 1 DUCTS I GAS LINE I FINAL DATE ACCEPTED BY I WOOD STO:rE 1 PELLET 1 CHIMNEY : I MANUFACTlJRED HOMES FOOTING I SLAB I BLOCKING I &. HOLD DOWNS , SKJRTlNG PLANNINd DEPT SEP ARA TE PERMIT #' 5 SEPA P ARKING/1--IGHTlNG ESA LANDSCA~ING SHORELINE I FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCYIUSE , RESIDENTIAL DATE YES NO COMMERCIAL DATE ACCEPTED I YES NO I 417-4735 ELECTRICAL ELECTRICAL - LIGHT DEPT LIGHT DEPT I CONSTRUCTIONR W IPWI CONSTRUCTION - R W ENGINEERING 417-4807 PW 1 ENGINEERING I FIRE I 4J 7-4653 FIRE DEPT PLANNING DEFT 4]7-4750 PLANNING DEPT I BUTLDlNG 417-4815 BUTLDlNG T \POllCI05\] JO~ 15 bUlldmg penmt 1l15peCtJon recOld05 wpd [1/4/2005] CITY OF PORT ANGELES DEPARTMENT OF COMMUNITY DEVELOPMENT - BUILDING DIVISION 321 EAST 5TH STREET, PORT ANGELES, W A 98362 Application Number . . . . . 07-00000610 Application p~n number 157010 Page Date 2 6/14/07 Spec~al Notes and Comments has no comments 06/12/2007 11.32 AM SROBERDS --The proposal will result ~n a res~dent~al add~tion in the RS-7 zone for total lot coverage of 24$ No land use ~ssues ant~c~pated San~tary sewer connect~on ~nspect~on ~s requ~red by Public Works prior to back f~ll of ditch 24 hour advance not~ce is requ~red Other Fees STATE SURCHARGE 4 50 Fee summary Charged Pa~d Cred~ted Due ----------------- ---------- ---------- ---------- ---------- Perm~t Fee Total 547.30 547.30 .00 .00 Plan Check Total 150.30 150 30 00 .00 Other Fee Total 4.50 4.50 .00 .00 Grand Total 702.10 702.10 00 .00 Separate Permits are required for electrical work, SEPA, Shoreline, ESA, utilities, pnvate and public Improvements. ThiS permit becomes null and void If work or construction authonzed is not commenced within 180 days, if construction or work is suspended or abandoned for a period of 180 days after the work as commenced, or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All prOVIsions of laws and ordinances governing this type of work Will be compiled with whether speCified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction Signature of Contractor or Authonzed Agent Date Signature of Owner (If owner IS builder) Date r \Pohcles\1102_15 bUlldmg penmt IIlSpectlO11 rccOld05 wpd [1/4/2005] BUILDING PERMIT INSPECTION RECORD C<\LL 417-48]5 FOR BUILDING INSPECTIONS C<\LL 417-4735 FOR ELECTRICALlNSPECTJONS CALL 417-4807 FOR PUBLIC WORKS l1TILITIES PLEASE PROVIDE A IvllNIMUM 24 HOUR NOTICE IT IS UNLA H'FUL TO COVER, INSULATE OR CONCEAL A.I\'1' WOPJl BEFORE l/VSPECTED A.ND ACCEPTED. POST P.cRMIT IN A CONSPICUOUS LOCAT10N 0 KEEP PERMIT CARD AND APPROVED PLANS AT .lOB SITE ---1 , 6"' , INSI'ECTION TYPE DATE ACCEPTED COMMENT,- i YES. NO FOUNOA nON n ba.r I f I q / 01 J"L-L FOOrlNGS i ({19Ic)( -:)LL- SHEAR WALjLS 1 WALLS , FOlJNDA TION DRAfNAGEI DOWN SPOUTS PIERS i I I POST HOLESi (POLE BLDGS ) I I'LUMlIlNG i UNDER FLOORI SLAB 1'1301 n, 1 '\L.-L.- ROUGH-IN I Gf ~I~-Ol :rIA,. WATER UN1=' (METER TO BLDG) GAS LINE FINAL l2.-63-()7 DATE J:U- ACCEPTED BY , BACJ~ FLOW / WATER AIR SEAL ! I t) - I"~ -o"l dL....L, WALLS , CEILING i I FRAMING , 10-03-01 ':rL.,0 , JOISTS 1 GIRDERS , SHEAR Vi ALL/HOLD DOWNS WALLS 1 RO:OF 1 CEILING DP.I'WALL (,INTERJOR BRACED PANEL ONLY) T-BAR INSULATION! 10 -0<6-01 :ru.... SLAB I WALL 1 FLQOR 1 CEILING I MECHANICAL ROUGH-IN i HEATPU~/FURNACE/DUCTS GAS LINE i FINAL 12-3-01 DATE :ILl- ACCEPTED BY WOOD STO% 1 PELLET 1 CHIMNEY , MANUFACTURED HOMES , FOOTING 1 SLAB BLOCKING 1& HOLD DOWNS SKJRTING , , PLANNINci DEPT SEPARATE PERMIT #'s SEPA PARKING/!l,IGHTING ESA LANDSCARING SHORELINE , FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCYIUSE , RESIDENTIAL DATE YES NO COMMERCIAL DATE ACCEPTED , YES NO , ELECTRJCAL - LlGHT DEPT 417-4735 ELECTRJCAL , LIGHT DEPT CONSTRUC1;IONR W IPWI CONSTRUCTION - R W ENGINEERING 417-4807 PW 1 ENGINEERING FIRE 417-4653 FIRE DEPT PLANNING BEPT 417-4750 PLANNING DEPT , lZ....O.~-i)l -Sf..,L., BUILDING 417-4815 BUILDING - o ~ .-- o ftl , C> -<) 8 Vl f; /':) ~ ~ ~ ,-~ :1: o s T \PohCles\] J02 15 bUl1dmg pennll mspectJon recDld05 wpd [1/4/20051 , f ,ORT ~ lO~\ ~ L w;;;;;;;..a> ~ ~~ CITY OF PORT ANGELES PUBLIC WORKS - UTILITIES DIVISION 321 EAST 5TH STREET, PORT ANGELES, WA 98362 Application Number Appl~cation p~n number Property Address ASSESSOR PARCEL NUMBER. Tenant nbr, name Applicat~on type descr~pt~on Subdivis~on Name Property Use Property Zoning . Application valuat~on 07-00000610 Date 6/14/07 157010 210 ORCAS AVE 06-30-10-5-0-1912-0000- KEVIN & RACHEL SCHMIDT RES ADDITION RS7 RESDNTL SINGLE FAMILY 21740 Owner Contractor SCHMIDT KEVIN/RACHEL HATHAWAY CONSTRUCTION 2301 WEST 18TH ST 324 E 7TH STREET PORT ANGELES WA 98363 PORT ANGELES PORT ANGELES WA 98362 (360) 457-5627 Structure Information 000 000 RES. ADDITION Other struct ~nfo HARD SURFACE AREA Perm~t SANITARY SEWER HOOK UP Add~tional desc ALTER SEWER Permit pin number 104471 Permit Fee 40.00 Plan Check Fee 00 Issue Date 6/14/07 Valuation 21740 Expiration Date 12/11/07 Qty Un~t Charge Per Extens~on BASE FEE 40.00 Special Notes and Comments The F~re Department has reviewed the project application and has no comments 06/12/2007 11'32 AM SROBERDS --The proposal will result in a residential addition in the RS-7 zone for total lot coverage of 24$. No land use ~ssues anticipated Sanitary sewer connect~on ~nspection is required by Publ~c Works prior to back f~ll of ditch. 24 hour advance not~ce is required. Other Fees STATE SURCHARGE 4.50 Fee summary Charged Paid Cred~ted Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 40.00 40.00 00 00 Plan Check Total 00 00 00 .00 Other Fee Total 4.50 4 50 .00 00 Grand Total 44.50 44 50 00 00 Separate Permits are required for electrical work, SEPA, Shoreline, ESA, utilities, private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned for a period of 180aays after the work as commenced, or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any stat or local law regulating construction or the performance of construction. ~ _ ~ Signature of Contractor or Authorized Agent Date T.\Pohcles\1102.15R [1/05] PERMIT INSPECTION RECORD CALL 417-480Y FOR UTILITY INSPECTIONS PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE IT IS UNLA WFUL TO COVER, INSULA TE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT IN A CONSPICUOUS LOCATION KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE INSPECTION TYPE DATE ACCEPTED COMMENTS I YES NO PW UTILITIES ! (Engmeenng DIvIsIOn) WATERLINE 1 METER I SEWER CONNECTION SANITARY I STORM I SITE DRAINAGE ! SITE EROSION <[ONTROL PARKING I I SIDEWALK CURB & GUTTER I I DRIVEWAY APPROACH I BACK-FLOW DEVICE I I I , I I I . I I i I I I , I I , I , ! I I I I i I FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCYIUSE I RESIDENTIAL DATE YES NO COMMERCIAL DATE ACCEPTED I YES NO CONSTRUCTION R W 1 PWI CONSTRUCTION - R W ENGINEERING 417-4807 PW 1 ENGINEERING FIRE I 417-4653 FIRE DEPT. I PLANNING DEP! 417-4750 PLANNING DEPT BUILDING 417-4815 BUILDING I I T-\Pohcles\1102 15R [1/05] r ,1 0\ p()\U .iV ~. "(t ..., .I"~" r""""' 1".- ~~~~'';;:) "". '''''-~~,. '0;. ~~ : ::. "~ .... - , __ ~__c.~.~~_ .,. -. J \...~./ BUILDING PERMIT - APPLICATION Fill out COMPLETELY and in INK. Your applicatIOn and site plan MUST B COIviPLETE TO be accepLed Ioy rtvie-V\. If ymi have aDY questIOns, :;~11 PERMITS (360) 417-4815 FA.X(360)417-4711 Apphcant or Agent \4;J~ \"-' l ~kl SJ.u~t Owner.J~'.e~\~ ! ~~\ ~~ Address' ~O ~ O'(~ A:J0 Clty _frwi- Phone. ~~k-s ArchItect/Engmeer Phone. Contractorllq~t'-&p~/, Co,.,rI~ ~l0-- State LIcense # /flrtIHtCiDJ.:J..~XP' O"-O?~afPhone. 'f-~/- 5'o~7 Address: (:2- Y c-.. 7:t::i- ~ /' CIty: P A ZIp. r~ '< 6' ~- PROJECT ADDRESS. ~i 0 E Oy{lJLS /+Ii J Phone. 5tJG-/i 1~ ~b-I,1q ZIp: cr8{J&2- ZONING: LEGAL DESCRIPTION: Lot. CLALLAM COUNTY PARCEL NUJY.D3ER' Block: SubdIVIsIOn' TYPE OF WORK: SIZENALUATION: o Res1dential 0 New Constr 0 Re-roof 0 Stove SF. @ $ /SF = $ o MulTI-fannly 'l(;Addmon 0 Move 0 Garage :J..21'J SF.@$ 76.0'\ /SF =$ 16) 1'3C}, 2s0 o CommerCIal V Remodel 0 DemolItion 0 Deck SF @ $ /SF. = $ t) 000 .0-{') o R,p'" 0 S'gn 0 Oth", TOTAL V,ALUATION $ ~21~ ~~ES~kh~~~^~J ~:taJ:r1~~~::D:7add~ U?tILJhro1m _ ~~. ~-~Jnec- s COMIVIERCL4.LIRESIDENTlAL: Occupancy Group: Occupant Load. ConstrucTIon Type: No of Stones.....L Lo~ S~e. 1UVO EXlStmg Sq Ft \ ~~ & Proposed Sq Ft 2-1-0 = TOTAl. Sq Ft J', OS- Total lot coverage ~ % ESA/Wetland(s) SEPAChecklIstrequrred? 0 Yes 0 No Other APPROVALS: PLAN: BLDG: DPWD: FIRE: OTHER:_ PLANNING USE ONLY: VALUATION OF CONSTRUCTION: In all cases, a valuation amount must be entered by the applIcant Tills figure WIll be revIewed and may be revIsed by the Buildmg DIVlSlon to comply vnth current fee schedules Contact the P eIIDlt CoordInator at 417 -4815 for aSSIstance PLAN CHECK FEE' IF a plan check fee IS due 1t must be subnntted at the tIme the buildmg peIIDlt apphcaTIon and construCTIon plans are subnntted All other penmt fees are-due-at-the tJme of penmt Issuance. EXPIR.A.TION OF PLA.N REvIEw: lino peront is 1ssued Wltlnn 180 days of the date of application, the application will expire. The BUlldmg Official can extend the TIme for actlOn by the applIcant up to 180 days npon wntten request by the applIcant (see SectlOn RI 053.2 ofllie InternaTIonal BUlldmg/Res1denttal Code, 2003) No applicaTIon can be extended mOle than once. I hereby certify that I have read and exammed this application and know the same to be true and correct., I am authonzed to apply for thiS permit and understand that ft is my responSIbility to de~ i:.2m~ reqUl,:d ,not the edy's, and that J mt obtam such permits pnodo work T\Pohcles\BL-l102_13wpd ApplIcant: C;~ate: 5r1..,.~ 01 v p ~~yY\ ~l~' / ---- .,... ... .' -n ..' -- "2 \ YDf'~ :7 S~ I w o;.~ I I I 1 r, fY\ ebhoY\'t (A \ / I I veVlJ \ Wlt\l ~~ It f'LLEr FIGHT)r IV/ 'I SE\~IEr::: MAIIJ ----------------------- ! i , , , I , 1_____________-1 : I I 36'-0" , -._---- ~---------------- I 7'-0" 1 , ----r-;- , I f'r~OrcrT) LlI~t: , 50'-0" -------: , 7'-0"-! I 9 b N PROflEPTT' SETBACk L1J~E I i I ,-' ,;,' :ti I I I ! ~" " r~ , Jt:--- .... r- --~-I~__= II 9 I~ : : ~ I ~1- L I~ i I 9 10 ct:) ~ ' ,-' -', I ~" _ ,_ --"1 ___ prOPERTY SETBf,Ck :..1I1E ~ +---------------~------ 7'-0" ----1--- 25'-0" -------' - 13'-0" I 9 ;:t I ,----~ 5'-0"~ , ,-' <0', ;fl I CMII~Ef I,EVUJ & PJ.CHEL SCHMIDT fDDRESS 21[) ORUS A\/E POrT IljG~LES LEGf L LOT 7 BoLuS' 19 PUGET S(;UIID CooPEPATIVE COLOI~~'S 21lD fnr) 76 r f pl-,ReEL 063010501912 9 (:) N / I / I / I / J / I / I / I / . J - - - -/- - - - - - - - - - - - - - -0rcas-Ave:- - - - - - - - - - - _ _ _ _ _ _ _ __ / J / I " ...... CI) I C - o u c "- ...!.J J I I / I I I I I I f I I I I / I I f / I I I (6/12/20()7) Lu}da Pangrfe - Pe~mlf~7-61(j __-:~~:~- _--:_~~~~ge J I From: To: Date: Subject: Robert Larson James Lierly 6/8/2007 5:02 PM Permit 07-610 The addition at 210 Orcas Ave will enclose the electnc meter and create a code violation with the existing overhead service conductor. The existing overhead electnc service and meter WIll need to be relocated. Bob Larson Electncal Englneenng Specialist 360-417-4706 rlarson@C1tyofpa.us o c/;;o ......~ ,.f ELECTRICAL WORK PERMIT APPLICATI<Y-\! iJ . Job wired by )( Electrical Contractor 0 Owner Installation description o Commercial ~sidential License number Date Expires f;~E:7'L /!.J,J 6c-r ~ -j/ Ot:,7,. c3 Purchaser's mailing address / ~b 2-- 77H" ~ CU'~r /UJ City State ZIP _~~~ ~ 9r'Z.. Rz..... FAX number 3 t-/i-g /0 Electrical contractor name 1<.. 1.A2 o New )'altered/Addition fZC3P'-J'fC6 H66 /t1-vt?t:.. I~c-c- 0{- .. Premises owner's name Eo 1/ J#H'1<<c-n- Address of inspection ? 2-0 ot:.Cfl-S Me Cit ')3~ lLr /hr.Jh ~ .U/ /! (,.J / r/r 2-00 N'c-.J '*- P' 0/ ~ ..... - ~ -<. Owner as defined hy RCW./9.28.26J:(I) Owner will occupy the structure for two years after lhis electrical permit is finalized. (2) Owner is required to hjre an electrical contractor if above said property is for sale. relit or lease. After reading the above statement, I hereby certify that I am the owner of the above named property or a licensed electrical contractor. I am making the electrical instal- lation or <.Ilteration in compliance with the electrical laws, N.E.C., RCW. Chapter 19.28, WAC. Chapter 296-46B, The City of Port Angeles Municipal Code, and Utility Specifications. Signature o Cash o Check # ~reditCard Card# -og_-E/t'-~ Visa ~astercard Discover x Date: -I' -Ob Expiration Date of card -c--- Electrical Load Additions and or subtractions D NO LOAD CHANG28 )i!i..Baseboard z... ~ o Furnace KW o Heat Pump Ton D Fan-Wall KW Service Information LAR ;l..Overhead Service o Temp Service o Underground Service Voltage I ~-Zj;tO Phas~ 1 3 Service Size: ~ 1'1- Feeder Size: ~,If SAME DAY INSPECTION, CALL BEFORE 7:00 AM 360-417-4735 _/ Dale Approved By SERVICE ot~ Dale Approved By ROUGH-IN ~ WB' THERMOSTAT FINAL .~6~ DITCH FEEDER Date Approved By Date Approved By Inspection Date Area, Building or Equipment Inspected Action Taken Electrical Inspector '1-1'/-0(.. /.10 ~w";I?l-T fie AfJI'[l.ova. j. / Electrical Load Additions and or subtractions I:l NO LOAD CHANGES o . Baseboard KW o Furnace KW ....Overhead Service o Heat Pump _ Ton _ LAR D Temp Service o Fan-Wall :t KW Q Underground Service SAME DAY INSPECTION, CALL BEFORE 7:00 AM 360-417-4735 TIlERMOSTAT Jul 26 07 0743a '1./7 </7/( .'- ~--'~~.,~ .. ..- ,,".~-.... "\t- ~~ -... Job wired by ){Electrical Contractor 0 Owner Elj~ical ~ontra.}tor name IC- GJ bee", ~ Purchaser's mailing address IF37- r""y~ Cilv :s Gc.ttrr ~ Telephone number <17 License number Date: Expires flc..J ~&It: ~ Ob3C ~ C-W~r d/J State ZIP 91'S ,J-'Z- Ur1- FAX number PremiSCii owner's name e/J Address of inspection ;;2 ~O Citv j) . t:...() If..;, /1/4 PH I#C!-rt.- C) tt..C /.I S /I-u; I1-uJ f1 eu::-S UA4 Phone number to schedule inspection: Owner os uejifll!d by RCWJ9.28.26/ :(f) OlvNcr will OCCUpy (he strllcture for two }'l'ars aji~r this dee-tricot permit i.s finalized. (2) Owner ;s required tu hire an electrical COIl/raclO, If above said properly is for sale, renl or lea.~e. After reading the above statement, I hereby certify that I am the owner of the abo....e named property or a licensed electrical contractor. I am making the electrical instal- lation Of" alteration in compliance with the electrical Jaws, N.E.C., RCW. Chapter 19.28, W^C~ Chapter 296-468, The City of Port Angeles Municipat Code. and Utility Specifications. Signature owner, electrical cOlltractor or electrical admini.strator x. Date: 7- U-o'7 :TDn Appro...ed 8y D~l" DITaI pp'o...ed &y Dale . Inspection Date Area, Building or Equipment Inspecled 7- j/-<J 7 --- 01"-10 p1 '. J . h ELECTRICAL WORK PERMIT APPLICATION /' ~ Installation description o Commercial ... Residential DNew D Altered! Addition INS I PGC"ZJ Nc-zV "Z..-<'D ~ ~ " r ff,t.,.> w h _I ~ ~-=-c... - , . n r _ I<-L.~';.~ i!.t5~L I/-r G;rc.rsr / /p-...~ "Z.<D Rz-;,<J ,fzu:J ;t2.G La;C.d-72.-=- /Va-...> 1L.t>~ .0 k~ TV o Cash 0 Check # <<..credit Card Visa Mastercard Discover Card# _t?~~-~~t--6- ___-__~_ Expiration Date of card Service Information VOltagelZi('Z fC P~ase..s-1 0 3 Service Size: ~ Feeder Size: '- 0 0 Af'JII"Ovell [;I)" u, ERVICE ~ ....rl'''w~,j tly FErnER Appru\lc<l B). D..1C Ar.r.m'eu lly AClion T"kcn Eh:ctricaJ IlIspector IP eX . CITY OF PORT ANGELES LIGHT DIVISION FAX TRANSMISSION COVER SHEET Date: To: Fax: Re: Sender: 8/8/07 --(OD Inspe ons thy Trainor Phone: 417-4724 . Fax: 417-4729 YOU SHOULD RECEIVE 1 PAGE, INCLUDING THIS COVER SHEET. IF YOU DO NOT RECEIVE ALL THE PAGES, PLEASE CALL (360) 417-4724. Please inspect for: Becker Electric - Richard Becker 477-1398 220 Orcas t~~ CfrItIC e:f 6~'~ Wall Cover Inspection Thank you, Kathy S, B' 01 -V 3 \ ~. Of Br~'O ~ 01 t(L/~ . .~ '}:;vc--r- ,. ~~ ,G Sep 28 07 07:05a Current Electric 3604571873 p.1 . , G.-5B ELECTRICAL WORK PERMIT APPLlCATIO"'.w:' r /installation descriplion Jvb wired b)' ':Q. Electrical Contractor DOwner o Commercial Q Residential Electrical contractor name: License number Date Expires DNew }\AlteredlAdditioD "',",K~G'II""';.r'[ C L.-f;L-:--r.e ,L. A- l .c.~cJLE;;b.c:...:\ lo:o l prJ Purchaser's: mailil1{: address pc, C>O'(.:. Z-"1~ 7 Mn,/;::" 5&'-C.vlL-E- ""Or) . J , Citll StOlte ZIP i rrf-l A-., 6~C 65 v./+ '1S3c; 2- C'U:Lt,<:'" ~ Teh.:phone number fAX number ~j 3t;o- '1 ')7- j $3~j 3(.Cl - L/57-t?:l73 I Premises owner's name j-f,tf '7"-"1-,,-/4./ c(;.v> , r,2v~'~ a...'~ Addres!> of inspectioll - - - - - Z; 0 o..z.c"t-5 13fJ Cit ,A.vCEU::.5 C?05W Pog..,.. Phonc number to schedule .iosp4:ction.: J /;2 - /Y3 - {) 7 3GO-' (. 7C.'" 3"1 '7'1 Owner a:~ defined by RCW./9.18.26/:(I) o.\'""r wiJ{ occupy tlte struclllrcfor two //0. years after tM\ elecrrical permit is finalized. (2) Owller is required to hire an elecrrical EL., " c:omractor if abave said propert)' is for .,-ale, r-r!lIf or tease. r //-/-'/.L- A ficr reading thc above statement. [ hereby certify that I am the owner oi the above named propert}' or 3 licensed eleclrica.l conlroclor. [ am ma'king the electrical ins1al- card Discover Jalion or alteroiltion in compliance wilh the eleClrical laws, N.E.C., RCW. Chapter 19.28. WAC. Chapter 296-468, The City of Port Angeles Municipltl Code, and - Ulilily SpecificOllions. ----- - :g~nec.:;::::;: "~t~i:;: a;i;;;;' r Expiration Date - ( I nsp;]iOn fee of card $. 5"" o..J2 Eleclrical Load Ad itions nd or subtracti ns / ~.~,. ~ ..'.,.'.' ~~ \'S~:o:l ~ i cif d a o NO LOAD CHANGES o BaseboaJd v:yv a Furnace _ K:rN ClHeatPump _,Ton_LAR CI Fan-Wall K:rN Service Information o Vottage Phase 0 1 0 3 Service Size: Feeder Size: ,Q'6verhead Service o Temp Service D Underground Service SAME DAY INSPECTION. CALL BEFORE 7:00 AM 360-417-4735 ROUGH-IN J~ n '~!::~h7 ~ I1INAL "1!/~~ ~B' THERMOSTAT SERVICE 7~ Dale }\f1prol'ctl By DITOI FElDER D~te ~flrlClvcd Ily I);alc ApprovcJ By Inspcclion Dale Area, Building OT Equipment lnspcctcd Action Taken 10-,>".07 I ' r 10 /11/1,,,,,714/-.1 37z. I~ .~.... /11,f$r 71> /l'IIIs'T / El~ctrical Inspector -fi "'.;;;.> CITY OF PORT ANGELES PUBLIC WORKS - ELECTRICAL DIVISION :121 EAST 5TH STREET. PORT ANGELES. WA 98J62 ELECTRICAL PERMIT Issued: 12/08/97 Permit No: 6147 OWNER/APPLICANT------------------------PROPERTY LOCATION------------------------ DOROTHY RASSMUSSEN 210 ORCAS E Lot: Block: Sub: Parc No: Port Angeles, 360/000-0000 T: WA 98360 Long Legal:' S: CONTRACTOR-----------------------------DESIGNER--------------------------------- ANGELES ELECTRIC 524 E. FIRST ST. PORT ANGELES, WA 98362 360/45:1-9264 , 000/000-0000 PROJECT INFO-------------------------------------------------------------------- prj Type: RES. MISC. prj Value: $0.00 Occ Type: Cnstr Type: SERVICE CHANGE Occ Grp: Occ Load: Land Use: Electrical Heat Baseboard KW: Furnace KW: Heat Pump KW: Fan/Wall KW: o o o o Service Type Riser X Overhead Service Underground Service Temp Service Voltage: Diameter: Service Size: Feeder Size: 120,240 X-I -3 200 AMPS DAMPS PROJECT NOTES------------------------------------------------------------------- CHANGE SERVICE ONLY c' , , PROJECT FEES ASSESSMENT---------------------------------------------------~----- ~ervice: $57.00 Additional Feeders: $0.00 Circuit Wiring: $0.00 Temp Service: $0.00 $0.00 Misc TOTAL FEE: Amount Paid: $57.00 $57.00 --------------------------------- --------------------------------- TOTAL FEE: $57.00 Balance Due: $0.00 COMMENTS/ACTION NEEDED ELECTRICAL PERMIT INSPECTION RECORD CALL 417-4735 FOR ELECTRICAL INSPECTIONS. PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. rr IS UNLA WFUL TO COlIER. INSULA TE OR CONCEAL ANY WORK BEFORE rr IS INSPECTED AND ACCEPTED. KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE INSPECTION TYPE DATI< ACC1ll'TED COMMENTS YES I NO IlnTlr.u_IN I CUYbK :b /~ 101/2 I t1.:J"'-, F I I I GENERAL COMMENTS: PW-IID2.UI4I96J Application Number . . . . . 23-00000177 Date 2/22/23 Application pin number . . . 764178 Property Address . . . . . . 210 ORCAS AVE ASSESSOR PARCEL NUMBER: 06-30-10-5-0-1912-0000- Application type description ELECTRICAL ONLY Subdivision Name . . . . . . Property Use . . . . . . . . Property Zoning . . . . . . . RS7 RESDNTL SINGLE FAMILY Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc DHP ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ JAMES AND JEANINE DEMARCO BLACK DIAMOND ELECTRICAL CONTR 210 ORCAS AVE 502 BLACK DIAMOND RD PORT ANGELES WA 98362 PORT ANGELES WA 98363 (920) 213-1741 (360) 565-1035 ---------------------------------------------------------------------------- Permit . . . . . . ELECTRICAL ALTER RESIDENTIAL Additional desc . . Permit Fee . . . . 63.00 Plan Check Fee . . .00 Issue Date . . . . 2/22/23 Valuation . . . . 0 Expiration Date . . 8/21/23 Qty Unit Charge Per Extension 1.00 63.0000 ECH EL-R- BRANCH CIR WO/ SER FEED 63.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 63.00 63.00 .00 .00 Plan Check Total .00 .00 .00 .00 Grand Total 63.00 63.00 .00 .00 1 - 2 SINGLE-FAMILY ELECTRICAL PERMIT APPLICATION Pub! ic \Yorks and ULili ties Department 32 l E. 5th Street. Port ;\ngeles. WJ\ 98362 300.417.47]5 ! www.cilyofjJa us I electricalpcnnitsr21/cityofpa.us Project Address:--------------------------------------­ Project Description:--------------------------------------□Single-Family Residential D Duplex/ ARU Building Square footage: _______________ _ OWNER JNFORMATtON Name: ________________________ Email: ______________ _ Mailing Address: ________________________ Phone: ___________ _ ELECTRfCAL CONTRACTOR fNFORMATION Name: ___________________________ License: ___________ _ Mailing Address: ________________________ Expiration Date: ________ _ Email: Phone: ___________ _ PROJECT DETAILS Item Unit Charge Qy51ntit3£ :To1s.l (Quantity x Unit Charge) Service/Feeder 200 Amp. $120.00 $ Service/Feeder 201-400 Amp. $146.00 $ Service/Feeder 401-600 Amp. $205.00 $ Service/Feeder 601-1000 Amp. $262.00 $ Service/Feeder over 1000 Amp. $373.00 $ Branch Circuit W/ Service Feeder $5.00 $ Branch Circuit W/O Service Feeder $63.00 $ Each Additional Branch Circuit $5.00 $ Branch Circuits 1-4 $75.00 $ Temp. Service/Feeder 200 Amp. $93.00 $ Temp. Service/Feeder 201-400 Amp. $110.00 $ Temp. Service/Feeder 401-600 Amp. $149.00 $ Temp. Service/Feeder 601-1000 Amp. $168.00 $ Portal to Portal Hourly $96.00 $ Signal CircuiULimited Energy - 1 &2 DU. $64.00 $ Manufactured Home Connection $120.00 $ Ren ewable Elec. Energy: 5KVA System or less $102.00 $ Thermostat (Note: $5 for each additional) $56.00 $ First 1300 Sql;Jare Feet $120.00 $ Each Additional 500 square feet" $40.00 $ Each Outbuilding / Detached Garage $74.00 $ Each Swimming Pool/ Hot Tub $110.00 $ TOTAL $ Owner as defined by RCW.19.28.261: (1) Owner will occupy the structure for two years after this electrical permit is finalized. (2) Owner is required to hire an electrical contractor if above said property is for sale, rent or lease. Permit expires after six months of last inspection. After reading the above statement, I hereby certify that I am the owner of the above named property or a licensed electrical contractor. I am making the electrical installation or alteration in compliance with the electrical laws, N.E.C., RCW. Chapter 19.28, WAC. Chapter 296- 468, The City of Port Angeles Municipal Code, and Utility Specifications and PAMC 14.05.050 regarding Electrical Permit Applications. Date Print Name Signature (0 Owner D Electrical Contractor/ Administrator) [Electrical Permit Applications may be submitted to City Hall or electricalpermits@cityofpa.us] '"'CJ CD PREPARED 2/21/23, 8:19:48 PAYMENT DUE CITY OF PORT ANGELES PROGRAM BP820L --------------------------------------------------------------------------- APPLICATION NUMBER:23-00000177 210 ORCAS AVE FEE DESCRIPTION AMOUNT DUE --------------------------------------------------------------------------- ELECTRICAL ALTER RESIDENTIAL 63.00 TOTAL DUE 63.00 Please present reciept to the cashier with full payment ELECTRICAL INSPECTION WIRING REPORT APPROVED NOT APPROVED DITCH ROUGH IN/COVER SERVICE FINAL COMMENTS NOTIFY INSPECTOR at (360) 808-2613 WHEN CORRECTIONS ARE COMPLETED WITHIN 15 DAYS DATE PERMIT # INSPECTOR 11/22/2023 23-177 TAP OWNER CONTRACTOR Black Diamond Electric PROJECT ADDRESS 210 E Orcas Ave Application Number . . . . . 24-00000289 Date 3/29/24 Application pin number . . . 629627 Property Address . . . . . . 210 ORCAS AVE ASSESSOR PARCEL NUMBER: 06-30-10-5-0-1912-0000- Application type description ELECTRICAL ONLY Subdivision Name . . . . . . Property Use . . . . . . . . Property Zoning . . . . . . . RS7 RESDNTL SINGLE FAMILY Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc Double Oven ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ JAMES AND JEANINE DEMARCO EXTRA MILE TECH & ELECT., LLC 210 ORCAS AVE 418 N. RACE ST. PORT ANGELES WA 98362 PORT ANGELES WA 98362 (920) 213-1741 (360) 457-5222 ---------------------------------------------------------------------------- Permit . . . . . . ELECTRICAL ALTER RESIDENTIAL Additional desc . . Permit Fee . . . . 95.10 Plan Check Fee . . .00 Issue Date . . . . 3/29/24 Valuation . . . . 0 Expiration Date . . 9/25/24 Qty Unit Charge Per Extension 1.00 95.1000 ECH EL-R- BRANCH CIR 1-4 95.10 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 95.10 95.10 .00 .00 Plan Check Total .00 .00 .00 .00 Grand Total 95.10 95.10 .00 .00 Public Works and Utilities Department 321 E. 5th Street, Port Angeles, WA 98362 360.417.4735 | www.cityofpa.us | electricalpermits@cityofpa.us EL1-2 SF 1 - 2 SINGLE-FAMILY ELECTRICAL PERMIT APPLICATION Project Address: Project Description: □Single-Family Residential □ Duplex / ARU Building Square footage: OWNER INFORMATION Name: Email: Mailing Address: Phone: ELECTRICAL CONTRACTOR INFORMATION Name: License: Mailing Address: Expiration Date: Email: Phone: PROJECT DETAILS Unit Charge Quantity Total (Quantity x Unit Charge) $190.20 $ $190.20 $ $285.30 $ $380.40 $ $475.50 $ $5.30 $ $95.10 $ $47.55 $ $95.10 $ $95.10 $ $190.20 $ $285.30 $ $380.40 $ $95.10 $ $95.10 $ $190.20 $ $190.20 $ Item Service/Feeder 200 Amp. Service/Feeder 201-400 Amp. Service/Feeder 401-600 Amp. Service/Feeder 601-1000 Amp. Service/Feeder over 1000 Amp. Branch Circuit W/ Service Feeder Branch Circuit W/O Service Feeder Each Additional Branch Circuit Branch Circuits 1-4 Temp. Service/Feeder 200 Amp. Temp. Service/Feeder 201-400 Amp. Temp. Service/Feeder 401-600 Amp. Temp. Service/Feeder 601-1000 Amp. Portal to Portal Hourly Signal Circuit/Limited Energy - 1&2 DU. Manufactured Home Connection Renewable Elec. Energy: 5KVA System or less Thermostat (Note: $5.30 for each additional)$95.10 $ First 1300 Square Feet $190.20 $ Each Additional 500 square feet``$47.55 $ Each Outbuilding / Detached Garage $95.10 $ Each Swimming Pool / Hot Tub $190.20 $ TOTAL $ Owner as defined by RCW.19.28.261: (1) Owner will occupy the structure for two years after this electrical permit is finalized. (2) Owner is required to hire an electrical contractor if above said property is for sale, rent or lease. Permit expires after six months of last inspection. After reading the above statement, I hereby certify that I am the owner of the above named property or a licensed electrical contractor. I am making the electrical installation or alteration in compliance with the electrical laws, N.E.C., RCW. Chapter 19.28, WAC. Chapter 296- 46B, The City of Port Angeles Municipal Code, and Utility Specifications and PAMC 14.05.050 regarding Electrical Permit Applications. Date Print Name Signature (□Owner □Electrical Contractor / Administrator) Pe r m i t # : New Construction Only [Electrical Permit Applications may be submitted to City Hall or epermits@cityofpa.us or faxed to 360.417.4711] ELECTRICAL INSPECTION WIRING REPORT APPROVED NOT APPROVED DITCH ROUGH IN/COVER SERVICE FINAL CORRECTIONS NEEDED: NOTIFY INSPECTOR at (360) 808-2613 WHEN CORRECTIONS ARE COMPLETED WITHIN 15 DAYS DATE PERMIT # INSPECTOR 3/29/24 24-289 TAP OWNER Contractor Extra Mile Electric ADDRESS 210 Orcas Ave Application Number . . . . . 25-00000359 Date 3/27/25 Application pin number . . . 363088 Property Address . . . . . . 210 ORCAS AVE ASSESSOR PARCEL NUMBER: 06-30-10-5-0-1912-0000- Application type description ELECTRICAL ONLY Subdivision Name . . . . . . Property Use . . . . . . . . Property Zoning . . . . . . . RS7 RESDNTL SINGLE FAMILY Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc PV system ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ STEVEN FURRH SOLGEN POWER LLC 210 ORCAS AVE 5715 BEDFORD STREET PORT ANGELES WA 98362 PASCO WA 99301 (360) 460-8618 (509) 508-0832 ---------------------------------------------------------------------------- Permit . . . . . . ELECTRICAL ALTER RESIDENTIAL Additional desc . . Permit Fee . . . . 475.50 Plan Check Fee . . .00 Issue Date . . . . 3/27/25 Valuation . . . . 0 Expiration Date . . 9/23/25 Qty Unit Charge Per Extension 1.00 95.1000 ECH EL-R- BRANCH CIR 1-4 95.10 1.00 190.2000 ECH EL-RENEWABLE 5-KVA OR LESS 190.20 1.00 190.2000 ECH EL-0-200 SRV FEEDER 190.20 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 475.50 475.50 .00 .00 Plan Check Total .00 .00 .00 .00 Grand Total 475.50 475.50 .00 .00 Public Works and Utilities Department 321 E. 5th Street, Port Angeles, WA 98362 360.417.4735 | www.cityofpa.us | electricalpermits@cityofpa.us EL1-2 SF 1 - 2 SINGLE-FAMILY ELECTRICAL PERMIT APPLICATION Project Address: Project Description: □Single-Family Residential □ Duplex / ARU Building Square footage: OWNER INFORMATION Name: Email: Mailing Address: Phone: ELECTRICAL CONTRACTOR INFORMATION Name: License: Mailing Address: Expiration Date: Email: Phone: PROJECT DETAILS Unit Charge Quantity Total (Quantity x Unit Charge) $190.20 $ $216.20 $ $285.30 $ $380.40 $ $475.50 $ $5.30 $ $95.10 $ $5.30 $ $95.10 $ $95.10 $ $190.20 $ $285.30 $ $380.40 $ $95.10 $ $95.10 $ $190.20 $ $190.20 $ Item Service/Feeder 200 Amp. Service/Feeder 201-400 Amp. Service/Feeder 401-600 Amp. Service/Feeder 601-1000 Amp. Service/Feeder over 1000 Amp. Branch Circuit W/ Service Feeder Branch Circuit W/O Service Feeder Each Additional Branch Circuit Branch Circuits 1-4 Temp. Service/Feeder 200 Amp. Temp. Service/Feeder 201-400 Amp. Temp. Service/Feeder 401-600 Amp. Temp. Service/Feeder 601-1000 Amp. Portal to Portal Hourly Signal Circuit/Limited Energy - 1&2 DU. Manufactured Home Connection Renewable Elec. Energy: 5KVA System or less Thermostat (Note: $5.30 for each additional)$95.10 $ First 1300 Square Feet $190.20 $ Each Additional 500 square feet``$47.55 $ Each Outbuilding / Detached Garage $95.10 $ Each Swimming Pool / Hot Tub $190.20 $ TOTAL $ Owner as defined by RCW.19.28.261: (1) Owner will occupy the structure for two years after this electrical permit is finalized. (2) Owner is required to hire an electrical contractor if above said property is for sale, rent or lease. Permit expires after six months of last inspection. After reading the above statement, I hereby certify that I am the owner of the above named property or a licensed electrical contractor. I am making the electrical installation or alteration in compliance with the electrical laws, N.E.C., RCW. Chapter 19.28, WAC. Chapter 296- 46B, The City of Port Angeles Municipal Code, and Utility Specifications and PAMC 14.05.050 regarding Electrical Permit Applications. Date Print Name Signature (□Owner □Electrical Contractor / Administrator) Pe r m i t # : New Construction Only [Electrical Permit Applications may be submitted to City Hall or epermits@cityofpa.us or faxed to 360.417.4711] SCOPE OF WORK 1.2.1 CONTRACTOR IS RESPONSIBLE FOR THE DESIGN AND SPECIFICATIONS OF THE GRID-TIED PHOTOVOLTAIC & ENERGY STORAGE SYSTEM. THE CONTRACTOR WILL BE RESPONSIBLE FOR COLLECTION OF EXISTING ONSITE CONDITIONS TO DESIGN, SPECIFY, AND INSTALL THE ROOF-MOUNTED PV SYSTEM AND ENERGY STORAGE SYSTEM DETAILED IN THIS DOCUMENT SATELLITE MAP COVER PAGEPV-00 EQUIPMENT DATASHEETS ATTACHED EQUIPMENT SPECIFICATIONS ENLARGED VIEW ELECTRICAL DIAGRAM WARNING LABELS ATTACHMENT PLAN & DETAILS SHEET INDEX PV-02 PV-03 PV-04 PV-06 PV-05 VICINITY MAP SITE PLANPV-01 DIRECTORY PLACARDPV-05.1 FRAMING DETAILPV-03.1 SITE NOTES 2.1.1 A LADDER WILL BE IN PLACE FOR INSPECTION IN ACCORDANCE WITH OSHA REGULATIONS. 2.1.2 THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS A UTILITY INTERACTIVE SYSTEM WITH STORAGE BATTERIES. 2.1.3 THE SOLAR PV INSTALLATION WILL NOT OBSTRUCT ANY PLUMBING, MECHANICAL, OR BUILDING ROOF VENTS. 2.1.4 PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL EQUIPMENT WILL BE PROVIDED IN ACCORDANCE WITH SECTION NEC 110.26. 2.1.5 ROOF COVERINGS SHALL BE DESIGNED, INSTALLED, AND MAINTAINED IN ACCORDANCE WITH THIS CODE AND THE APPROVED MANUFACTURER'S INSTRUCTIONS SUCH THAT THE ROOF COVERING SERVES TO PROTECT THE BUILDING OR STRUCTURE. EQUIPMENT LOCATIONS 2.2.1 ALL EQUIPMENT SHALL MEET MINIMUM SETBACKS IN ACCORDANCE WITH NEC 110.26. 2.2.2 WIRING SYSTEMS INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR EXPECTED OPERATING TEMPERATURE AS SPECIFIED BY NEC 690.31 (A),(C) AND NEC TABLES 310.15 (B)(2)(A) AND 310.15 (B)(3)(C). 2.2.3 JUNCTION AND PULL BOXES PERMITTED INSTALLED UNDER PV MODULES IN ACCORDANCE WITH NEC 690.34. 2.2.4 ADDITIONAL AC DISCONNECT(S) SHALL BE PROVIDED WHERE THE INVERTER IS NOT WITHIN SIGHT OF THE AC SERVICING DISCONNECT. 2.2.5 ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL IN ACCORDANCE WITH NEC APPLICABLE CODES. 2.2.6 ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR OUTDOOR USAGE WHEN APPROPRIATE. STRUCTURAL NOTES 2.3.1 RACKING SYSTEM & PV ARRAY WILL BE INSTALLED IN ACCORDANCE WITH THE CODE-COMPLIANT INSTALLATION MANUAL. TOP CLAMPS REQUIRE A DESIGNATED SPACE BETWEEN MODULES, AND RAILS MUST ALSO EXTEND A MINIMUM DISTANCE BEYOND EITHER EDGE OF THE ARRAY/SUB-ARRAY, IN ACCORDANCE WITH RAIL MANUFACTURER’S INSTALLATION PRACTICES. 2.3.2 JUNCTION BOX WILL BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. IF ROOF-PENETRATING TYPE, IT SHALL BE FLASHED & SEALED PER LOCAL REQUIREMENTS. 2.3.3 ROOFTOP PENETRATIONS FOR PV RACEWAY WILL BE COMPLETED AND SEALED W/ APPROVED CHEMICAL SEALANT PER CODE BY A LICENSED CONTRACTOR. 2.3.4 ALL PV RELATED ROOF ATTACHMENTS TO BE SPACED NO GREATER THAN THE SPAN DISTANCE SPECIFIED BY THE RACKING MANUFACTURER OR PROFESSIONAL ENGINEERING GUIDANCE. 2.3.5 WHEN POSSIBLE, ALL PV RELATED RACKING ATTACHMENTS WILL BE STAGGERED AMONGST THE ROOF FRAMING MEMBERS. WIRING & CONDUIT NOTES 2.4.1 ALL CONDUIT AND WIRE WILL BE LISTED AND APPROVED FOR THEIR PURPOSE. CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING. 2.4.2 CONDUCTORS SIZED IN ACCORDANCE WITH THE NEC 2.4.3 AC CONDUCTORS TO BE COLORED OR MARKED PER NEC 2.4.4 LISTED OR LABELED EQUIPMENT SHALL BE INSTALLED AND USED IN ACCORDANCE WITH ANY INSTRUCTIONS INCLUDED IN THE LISTING OR LABELING PER NEC GROUNDING NOTES 2.5.1 GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE, AND GROUNDING DEVICES EXPOSED TO THE ELEMENTS SHALL BE RATED FOR SUCH USE. 2.5.2 PV EQUIPMENT SHALL BE GROUNDED IN ACCORDANCE WITH NEC 690.43 AND NEC TABLE 250.122. 2.5.3 METAL PARTS OF MODULE FRAMES, MODULE RACKING, AND ENCLOSURES CONSIDERED GROUNDED IN ACCORDANCE WITH NEC 250.134 AND 250.136(A). 2.5.4 EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED IN ACCORDANCE WITH NEC 690.45 AND INVERTER MANUFACTURER'S INSTALLATION PRACTICES 2.5.5 EACH MODULE WILL BE GROUNDED AS SHOWN IN MANUFACTURER DOCUMENTATION AND APPROVED BY THE AHJ. 2.5.6 THE GROUNDING CONNECTION TO A MODULE SHALL BE ARRANGED SUCH THAT THE REMOVAL OF A MODULE DOES NOT INTERRUPT A GROUNDING CONDUCTOR TO ANOTHER MODULE. 2.5.7 GROUNDING AND BONDING CONDUCTORS, IF INSULATED, SHALL BE COLORED GREEN OR MARKED GREEN IF #4 AWG OR LARGER PER NEC 250.119 2.5.8 THE GROUNDING ELECTRODE SYSTEM COMPLIES WITH NEC 690.47 AND NEC 250.50 THROUGH 250.106. IF EXISTING SYSTEM IS INACCESSIBLE, OR INADEQUATE, A GROUNDING ELECTRODE SYSTEM PROVIDED IN ACCORDANCE WITH NEC 250, NEC 690.47 AND THE AHJ. 2.5.9 GROUND-FAULT DETECTION SHALL COMPLY WITH NEC 690.41(B)(1) AND (2) TO REDUCE FIRE HAZARDS DISCONNECTION AND OVERCURRENT PROTECTION NOTES 2.6.1 DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS OPENED THE CONDUCTORS REMAINING ENERGIZED ARE CONNECTED TO THE TERMINALS MARKED “LINE SIDE” (TYPICALLY THE UPPER TERMINALS). 2.6.2 DISCONNECTS TO BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BE LOCKABLE, AND BE A VISIBLE-BREAK SWITCH 2.6.3 PV SYSTEM CIRCUITS INSTALLED ON OR IN HABITABLE BUILDINGS SHALL INCLUDE A RAPID SHUTDOWN FUNCTION TO REDUCE SHOCK HAZARD FOR EMERGENCY RESPONDERS IN ACCORDANCE WITH 690.12 2.6.4 ALL OCPD RATINGS AND TYPES SPECIFIED ACCORDING TO NEC 690.8, 690.9, AND 240. 2.6.5 INVERTER ON-GRID BRANCHES SHALL BE CONNECTED TO A SINGLE BREAKER OR GROUPED FUSE DISCONNECT(S) IN ACCORDANCE WITH NEC 110.3(B). 2.6.6 IF REQUIRED BY THE AHJ, SYSTEM WILL INCLUDE ARC-FAULT CIRCUIT PROTECTION IN ACCORDANCE WITH NEC 690.11 AND UL1699B. INTERCONNECTION NOTES 2.7.1 LOAD SIDE INTERCONNECTION SHALL BE IN ACCORDANCE WITH NEC 705.12. 2.7.2 THE SUM OF THE UTILITY OCPD AND INVERTER CONTINUOUS OUTPUT MAY NOT EXCEED 120 PERCENT OF BUSBAR RATING PER NEC 705.12. 2.7.3 THE SUM OF 125 PERCENT OF THE POWER SOURCE(S) OUTPUT CIRCUIT CURRENT AND THE RATING OF THE OVERCURRENT DEVICE PROTECTING THE BUSBAR SHALL NOT EXCEED 120 PERCENT OF THE AMPACITY OF THE BUSBAR, PV DEDICATED BACKFEED BREAKERS MUST BE LOCATED OPPOSITE END OF THE BUS FROM THE UTILITY SOURCE OCPD PER NEC 705.12. 2.7.4 AT MULTIPLE ELECTRIC POWER SOURCES OUTPUT COMBINER PANEL, TOTAL RATING OF ALL OVERCURRENT PROTECTION DEVICES SHALL NOT EXCEED AMPACITY OF BUSBAR. HOWEVER, THE MAIN OVERCURRENT PROTECTION DEVICE MAY BE EXCLUDED IN ACCORDANCE WITH NEC 705.12. 2.7.5 FEEDER TAP INTERCONNECTION (LOAD SIDE) IN ACCORDANCE WITH NEC 705.12. 2.7.6 SUPPLY SIDE TAP INTERCONNECTION IN ACCORDANCE WITH TO NEC 705.12 WITH SERVICE ENTRANCE CONDUCTORS IN ACCORDANCE WITH NEC 230.42. 2.7.7 BACKFEEDING BREAKER FOR ELECTRIC POWER SOURCES OUTPUT IS EXEMPT FROM ADDITIONAL FASTENING PER NEC 705.12. GENERAL NOTES PHONE - (541) 816-4047 LIC. NO. - 226333 CONTRACTOR 3521 AVION DRIVE SUITE #200, MEDFORD, OR 97504 PURELIGHT POWER NEWCO LLC DESIGN CRITERIA 1. ROOF PITCH:22°, 22°, 22° 2. AZIMUTH:92°, 02°, 272° 3. MODULE:(09) YUKON SERIES SEG-410-BMD-HV 4. INVERTER:(03) HOYMILES HMS-900-2T-NA [240V] (03) HOYMILES HMS-400-1T-NA [240V] 5. NOMINAL AMPERAGE:14.76 AMPS 6. ROOF AREA:2148 FT² 7. PV ARRAY AREA:189.20 FT² 8. PV ARRAY WEIGHT:426.60 LBS 9. ROOF SURFACE TYPE: COMPOSITE SHINGLE 10. ROOF STRUCTURE:2"X4" TRUSS @ 24" OC 11. BUILDING STORY:ONE STORY 12. SNOW LOAD:25 PSF 13. WIND SPEED: 110 MPH 14. WIND EXPOSURE: B 15. RISK CATEGORY: II PROJECT NOTES 1.1.1 THIS PHOTOVOLTAIC (PV) & ENERGY STORAGE SYSTEM SHALL COMPLY WITH THE RELEVANT YEAR OF THE NATIONAL ELECTRIC CODE (NEC), ALL MANUFACTURER’S LISTING AND INSTALLATION INSTRUCTIONS, AND THE RELEVANT CODES AS SPECIFIED BY THE AUTHORITY HAVING JURISDICTION’S (AHJ) APPLICABLE CODES. 1.1.2 THE UTILITY INTERCONNECTION APPLICATION MUST BE APPROVED AND THE PV & ENERGY STORAGE SYSTEM MUST BE INSPECTED PRIOR TO OPERATION 1.1.3 ALL PV & ENERGY STORAGE SYSTEM COMPONENTS; MODULES, UTILITY-INTERACTIVE INVERTERS, BATTERIES, AND SOURCE CIRCUIT COMBINER BOXES ARE IDENTIFIED AND LISTED FOR USE IN PHOTOVOLTAIC SYSTEMS AS REQUIRED BY NEC AND OTHER GOVERNING CODES 1.1.4 ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE. IF EXPOSED TO SUNLIGHT, IT SHALL BE UV RESISTANT. ALL PLAQUES AND SIGNAGE WILL BE INSTALLED AS REQUIRED BY THE NEC AND AHJ. NEW PHOTOVOLTAIC ROOF MOUNTED SYSTEM 3.690 KW DC/3.540 KW AC & ENERGY STORAGE SYSTEM - 15 KWH 210 ORCAS AVE, PORT ANGELES, WA 98362 PV-00 2/26/2025 SHEET TITLE DRAWN DATE DRAWN BY TSD SHEET NUMBER REV DATEDESCRIPTION REVISIONS PROJECT NAME AHJ STAMP APN #: 063010501912 AHJ: CITY OF PORT ANGELES UTILITY: CITY OF PORT ANGELES STEVEN FURRH 210 ORCAS AVE, PORT ANGELES, WA 98362 (360) 640-8618 STEVENFURRH@YAHOO.COM COVER PAGE STRUCTURAL STAMP SYSTEM SIZE:DC SIZE: 3.690 KW DC-(STC) AC SIZE: 3.540 KW AC NEW PV SYSTEM SPECIFICATIONS BATTERY:(01) FRANKLINWH APOWER 2, 15 KWH APPLICABLE CODES ALL WORK SHALL CONFORM TO THE FOLLOWING CODES: 2021 WASHINGTON STATE BUILDING CODE 2021 WASHINGTON STATE RESIDENTIAL CODE 2021 WASHINGTON STATE FIRE CODE 2023 NATIONAL ELECTRICAL CODE AS ADOPTED BY CITY OF PORT ANGELESINVERTERS MUST BE CONFIGURED TO OPERATE ACCORDING TO IEEE 1547 ANTI-ISLANDING GRID PROFILE STRUCTURAL ONLY 02/28/2025 50'-0" 14 0 ' - 0 " 14 0 ' - 0 " 50'-0" 41 ' - 3 " 32 ' - 7 " 5'-2" 5'-0" DR I V E W A Y N SITE PLAN SCALE:1"-20'-0" - PROPERTY LINE - FENCE LINE LEGEND PV-01 1 SITE PLAN PV-01 2/26/2025 SHEET TITLE DRAWN DATE DRAWN BY TSD SHEET NUMBER REV DATEDESCRIPTION REVISIONS PROJECT NAME AHJ STAMP APN #: 063010501912 AHJ: CITY OF PORT ANGELES UTILITY: CITY OF PORT ANGELES STEVEN FURRH 210 ORCAS AVE, PORT ANGELES, WA 98362 (360) 640-8618 STEVENFURRH@YAHOO.COM ROOF ACCESS POINT (E) HOUSE FRONT OF HOUSE STRUCTURAL STAMP (E) DETACHED STRUCTURE NOTES 1.ESS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER’S INSTRUCTIONS AND THEIR LISTING AND COMPLIES WITH IFC 1207.11.2 & R328.3 2.COMPLIES WITH IFC 1207.11.3 & R328.4 AND WILL BE INSTALLED OUTDOORS ON EXTERIOR WALLS. 3.ESS ENERGY RATING OF 15.0KWH PER UNIT 15.0KWH TOTAL AND COMPLIES WITH IFC 1207.11.4 & R328.5 4.A COPY OF THE MANUFACTURER'S INSTALLATION, OPERATION, MAINTENANCE AND DECOMMISSIONING INSTRUCTIONS SHALL BE PROVIDED TO THE OWNER AND COMPLIES WITH R328.11. 5.ESS DOES NOT PRODUCE HYDROGEN OR OTHER FLAMMABLE GASES AND COMPLIES WITH IFC 1207.11.8 & R328.9 (E) FENCE ORCAS AVE ALLEY STRUCTURAL ONLY 02/28/2025 RO O F 1 RO O F 3 ROOF 2 N PV-02 2/26/2025 SHEET TITLE DRAWN DATE DRAWN BY TSD SHEET NUMBER REV DATEDESCRIPTION REVISIONS PROJECT NAME AHJ STAMP APN #: 063010501912 AHJ: CITY OF PORT ANGELES UTILITY: CITY OF PORT ANGELES STEVEN FURRH 210 ORCAS AVE, PORT ANGELES, WA 98362 (360) 640-8618 STEVENFURRH@YAHOO.COM SCALE:1"-10'-0" PLAN VIEW TOTAL ROOF AREA:2148 FT² TOTAL PV ARRAY AREA:189.20 FT² TOTAL % OF ROOF COVERED BY PV:8.81% = FLUE / PLUMBING VENT = MECHANICAL VENT NOTES: 1.ROOF ACCESS POINT SHALL NOT BE LOCATED IN AREAS THAT REQUIRE THE PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS WINDOWS OR DOORS, AND LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION IN LOCATIONS WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES OR SIGNS. 2.STRUCTURES, PATIO COVERS, AND/OR ADDITIONS BUILT WITHOUT PERMITS TO BE RESOLVED BY A SEPARATE PERMIT. LEGEND 44.65" 67 . 8 0 " FIRE SETBACKS36 " 18 " = STRING 1 ENLARGED VIEW ENLARGED VIEW PV-02 1 (N) JUNCTION BOX NEMA 3R (E) UTILITY METER (OVERHEAD SERVICE) METER #: 01564 ROOF ACCESS POINT JB STRUCTURAL STAMP SLOPE - 22° AZIMUTH - 272° MODULE QTY - 03 TRUSS - 2"X4" @ 24" O.C. SURFACE TYPE - COMPOSITE SHINGLE ROOF 3 SLOPE - 22° AZIMUTH - 02° MODULE QTY - 03 TRUSS - 2"X4" @ 24" O.C. SURFACE TYPE - COMPOSITE SHINGLE ROOF 2 SLOPE - 22° AZIMUTH - 92° MODULE QTY - 03 TRUSS - 2"X4" @ 24" O.C. SURFACE TYPE - COMPOSITE SHINGLE ROOF 1 UM AC D ESS NOT IN A LOCATION SUBJECT TO VEHICLE DAMAGE AND IS PROTECTED BY RETURN WALL, COMPLIES WITH IRC R330.8.1 & IFC 1207.11.7” AG T MDP ORCAS AVE FRONT OF HOUSE BACK OF HOUSE (N) FRANKLINWH AGATE (PV RAPID SHUTDOWN/ ESS DISCONNECT) (N) FRANKLINWH APOWER 2, 15 KWH BATTERY (N) AC DISCONNECT (SERVICE DISCONNECT) VISIBLE-OPEN, LOCKABLE, LABELED AND FUSED AC DISCONNECT (SQUARE D D224NRB) (E) MAIN DISTRIBUTION PANEL (BACKUP LOADS) (INSIDE LAUNDRY ROOM) AC DISCONNECT TO BE LOCATED WITHIN 10FT OF THE UTILITY METER = HOYMILES HMS-900-2T-NA [240V] (1 PER 2 MODULES) = HOYMILES HMS-400-1T-NA [240V] (1 PER 1 MODULE) ES S STRUCTURAL ONLY 02/28/2025 ATTACHMENT PLAN & DETAILS - ATTACHMENT POINTS - RAIL - STRUCTURAL MEMBER LEGENDDISTRIBUTED LOAD CALCULATIONS MODULE YUKON SERIES SEG-410-BMD-HV MODULE WEIGHT 47.40 LBS MODULE DIMENSIONS (L" x W")67.80" x 44.65" TOTAL QTY. OF MODULES 09 TOTAL WEIGHT OF MODULES 426.60 LBS TYPE OF RACKING PEGASUS STANDARD RAIL TYPE OF ATTACHMENT PEGASUS COMP MOUNT DISTRIBUTED WEIGHT OF RACKING 0.5 PSF TOTAL WEIGHT OF ARRAY 521.20 LBS AREA OF MODULE 21.02 SQFT. TOTAL ARRAY AREA 189.20 SQFT. DISTRIBUTED LOAD 2.75 PSF PV-03 2/26/2025 SHEET TITLE DRAWN DATE DRAWN BY TSD SHEET NUMBER REV DATEDESCRIPTION REVISIONS PROJECT NAME AHJ STAMP APN #: 063010501912 AHJ: CITY OF PORT ANGELES UTILITY: CITY OF PORT ANGELES STEVEN FURRH 210 ORCAS AVE, PORT ANGELES, WA 98362 (360) 640-8618 STEVENFURRH@YAHOO.COM NOTE: 6" MAXIMUM DISTANCE FROM ROOF SURFACE TO TOP OF PV MODULES STRUCTURAL STAMP TYPICAL ATTACHMENT PLAN (PORTRAIT) SCALE: NTSPV-03 1.0 TYPICAL ATTACHMENT PLAN (LANDSCAPE) SCALE: NTSPV-03 1.1 STRUCTURAL MEMBER @ 24" OC 4'-0" OC ATTACHMENT SPACING STRUCTURAL MEMBER @ 24" OC 4'-0" OC ATTACHMENT SPACING PV MODULE SEE ENLARGED VIEW (E) STRUCTURAL MEMBER MIN. 5/16" X 4-1/2" LAG BOLT W/ EPDM WASHER INTO STRUCTURAL MEMBER PEGASUS END/MID CLAMP PEGASUS STANDARD RAIL PEGASUS COMP MOUNT PEGASUS FLASHING PV MODULE (E) STRUCTURAL MEMBER Scale: NTS ATTACHMENT DETAIL PV-03 2 Scale: NTS ENLARGED VIEW PV-03 3 STRUCTURAL ONLY 02/28/2025 PV-03.1 2/26/2025 SHEET TITLE DRAWN DATE DRAWN BY TSD SHEET NUMBER REV DATEDESCRIPTION REVISIONS PROJECT NAME AHJ STAMP APN #: 063010501912 AHJ: CITY OF PORT ANGELES UTILITY: CITY OF PORT ANGELES STEVEN FURRH 210 ORCAS AVE, PORT ANGELES, WA 98362 (360) 640-8618 STEVENFURRH@YAHOO.COM FRAMING DETAIL SCALE: NTS FRAMING DETAIL PV-03.1 1 STRUCTURAL STAMP SLOPE - 22° AZIMUTH - 272° MODULE QTY - 03 TRUSS - 2"X4" @ 24" O.C. SURFACE TYPE - COMPOSITE SHINGLE ROOF 3 SLOPE - 22° AZIMUTH - 02° MODULE QTY - 03 TRUSS - 2"X4" @ 24" O.C. SURFACE TYPE - COMPOSITE SHINGLE ROOF 2 SLOPE - 22° AZIMUTH - 92° MODULE QTY - 03 TRUSS - 2"X4" @ 24" O.C. SURFACE TYPE - COMPOSITE SHINGLE ROOF 1 15 ' - 0 " 2 2 ° PV MODULES ROOF #1 2"X4" TRUSS @ 24" O.C.1'-7" 9'-6" LOAD BEARING WALL 10" 15 ' - 0 " 2 2 ° PV MODULES ROOF #2 1'-7" 5'-8" LOAD BEARING WALL 7" 8'-3"5.18" 6'-7" 15 ' - 0 " 2 2 ° PV MODULES ROOF #3 1'-7" 5'-8" LOAD BEARING WALL 6'-9" 4'-9" 2"X4" TRUSS @ 24" O.C. 2"X4" TRUSS @ 24" O.C. 5 . 1 8 " 5 . 1 8 " 5 . 1 8 " STRUCTURAL ONLY 02/28/2025 G N (N) FRANKLIN aGATE X 200A, NEMA 3R, 120/240V GEN RELAY GRID RELAY PV 30A/2P SMART CIRCUITS GATEWAY L2 L1 N G (3) #6 AWG THWN-2 (1) #10 AWG THWN-2 GRND 3/4" EMT CONDUIT (N) FRANKLIN aPOWER 2 15KWH, 10KW ESS 60A/2P (3) #4/0 AWG AL(3) #4/0 AWG AL (1) #4 EGC AL COMMUNICATION CABLE GEC M L2 NL2L1 TO UTILITY GRID LINE LOAD (E) BI-DIRECTIONAL UTILITY METER 1-PHASE, 3-W, 120V/240V EXISTING GROUNDING ELECTRODE SYSTEM METER #: 01564 G L1 L2 N L1 L2 N BONDED (3) #4/0 AWG AL (1) #4 EGC AL (N) AC DISCONNECT (SERVICE DISCONNECT): VISIBLE, LOCKABLE, LABELED 200A FUSED, (2) 200A FUSES, 240V, NEMA 3R, UL LISTED (SQUARE D D224NRB) ESS DISCONNECT PV RAPID SHUTDOWN 1 (2) #10 AWG (1) #10 EGC GN (E) 200A/2P MAIN BREAKER (E) 200A MAIN DISTRIBUTION PANEL 120/240V, 1-PHASE (BACKUP LOADS) (INSIDE LAUNDRY ROOM) (N) JUNCTION BOX 600 V, NEMA 3R UL LISTED MANUFACTURER PROVIDED TRUNK CABLE G L2 L1 (3) HOYMILES HMS-900-2T-NA [240V] MICROINVERTERS ONE UNDER EVERY TWO MODULES (240V) 09 MODULES AND 6 MICROINVERTERS IN BRANCH CIRCUIT 1 (3) HOYMILES HMS-400-1T-NA [240V] MICROINVERTER UNDER ONE MODULE (240V) YUKON SERIES SEG-410-BMD-HV #6 AWG BARE CU ROMEX CAN BE USED IN LIEU OF CONDUIT FOR INTERIOR BUILDING AND ATTIC RUNS ONLY. DO NOT USE ROMEX IN CONDUIT OR OUTDOOR ENVIRONMENTS. 2 3 E ELECTRICAL DIAGRAM MINIMUM WIRE SIZES CALLED OUT. USE OF LARGER WIRE IS ACCEPTABLE. 7/8" MINIMUM CONDUIT HEIGHT ABOVE ROOF SURFACE PV-04 2/26/2025 SHEET TITLE DRAWN DATE DRAWN BY TSD SHEET NUMBER REV DATEDESCRIPTION REVISIONS PROJECT NAME AHJ STAMP APN #: 063010501912 AHJ: CITY OF PORT ANGELES UTILITY: CITY OF PORT ANGELES STEVEN FURRH 210 ORCAS AVE, PORT ANGELES, WA 98362 (360) 640-8618 STEVENFURRH@YAHOO.COM DESCRIPTION FORMULA RESULT PV OVERCURRENT PROTECTION NEC 690.9(B) TOTAL INVERTER OUTPUT CURRENT x 1.25 = ((03 x 3.42) + (03 x 1.5))A x 1.25 18.45A (SELECTED OCPD = 30A) ELECTRICAL STAMP AC DISCONNECT TO BE LOCATED WITHIN 10FT OF THE UTILITY METER WIRE ID EXPECTED WIRE TEMP (°C) TEMP DERATE (90 °C) QTY OF CURRENT CARRYING CONDUCTORS CONDUIT FILL DERATE MINIMUM CONDUIT SIZE (TBD ON SITE) WIRE GAUGE & TYPE CONDUCTOR AMPACITY @ 90°C (A) CONDUCTOR AMPACITY @ 75°C (A) REQUIRED CIRCUIT CONDUCTOR AMPACITY (A) ADJUSTED CONDUCTOR AMPACITY @ 90 °C (A) NEUTRAL CONDUCTOR SIZE & TYPE GROUND WIRE SIZE & TYPE 1 25 1.04 2 1 3/4"#10 THWN-2 40 35 18.45 41.60 NONE #10 THWN-2 2 25 1.04 3 1 2"#4/0 THWN-2-AL 205 185 200.00 213.20 #4/0 THWN-2-AL #4 THWN-2-AL 3 25 1.04 3 1 2"#4/0 THWN-2-AL 205 185 200.00 213.20 #4/0 THWN-2-AL NONE INVERTERS MUST BE CONFIGURED TO OPERATE ACCORDING TO IEEE 1547 ANTI-ISLANDING GRID PROFILE Signed 2/27/2025 WARNING LABELS PV-05 2/26/2025 SHEET TITLE DRAWN DATE DRAWN BY TSD SHEET NUMBER REV DATEDESCRIPTION REVISIONS PROJECT NAME AHJ STAMP APN #: 063010501912 AHJ: CITY OF PORT ANGELES UTILITY: CITY OF PORT ANGELES STEVEN FURRH 210 ORCAS AVE, PORT ANGELES, WA 98362 (360) 640-8618 STEVENFURRH@YAHOO.COM ENERGY STORAGE SYSTEM DISCONNECT 14 LABELING DIAGRAM: RAPID SHUTDOWN FOR SOLAR PV SYSTEM 10 SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY. 8 ELECTRICAL SHOCK HAZARD WARNING TERMINALS ON LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION !1 WARNING DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM !2 THIS EQUIPMENT FED BY MULTIPLE SOURCES TOTAL RATING OF ALL OVERCURRENT DEVICES EXCLUDING MAIN POWER SUPPLY SHALL NOT EXCEED AMPACITY OF BUSBAR WARNING!3 MAXIMUM AC OPERATING CURRENT: NOMINAL OPERATING AC VOLTAGE: 14.76 AMPS 240 VAC PHOTOVOLTAIC AC DISCONNECT 6 PHOTOVOLTAIC POWER SOURCE7 PARALLEL GENERATION ON SITE11 SOLAR ELECTRIC PV PANELS 9 EMERGENCY DISCONNECT SERVICE DISCONNECT 17 NOMINAL VOLTAGE: MAXIMUM AVAILABLE ISC: ISC CLEAR TIME: DATE : ENERGY STORAGE SYSTEM DISCONNECT 15 ELECTRICAL STAMP MAIN PHOTOVOLTAIC SYSTEM AC DISCONNECT MAIN DISTRIBUTION PANEL (BACKUP LOADS) ESS FRANKLIN A-GATE (PV RAPID SHUTDOWN/ ESS DISCONNECT) AC DISCONNECT (SERVICE DISCONNECT) UTILITY METER (DIRECTORY) 11 2 8 17 TRI POWER SOURCES SECOND SOURCE IS PHOTOVOLTAIC SYSTEM WARNING!16 10 14 15 16 6 Signed 2/27/2025 PV-05.1 2/26/2025 SHEET TITLE DRAWN DATE DRAWN BY TSD SHEET NUMBER REV DATEDESCRIPTION REVISIONS PROJECT NAME AHJ STAMP APN #: 063010501912 AHJ: CITY OF PORT ANGELES UTILITY: CITY OF PORT ANGELES STEVEN FURRH 210 ORCAS AVE, PORT ANGELES, WA 98362 (360) 640-8618 STEVENFURRH@YAHOO.COM DIRECTORY PLACARD MULTIPLE SOURCES OF POWER. POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: CAUTION ADDRESS: 210 ORCAS AVE, PORT ANGELES, WA 98362 EMERGENCY CONTACT: (541) 200-2896 DIRECTORY PLACARD: ROOF ACCESS POINT FR O N T O F H O U S E N UTILITY METER ELECTRICAL STAMP OR C A S A V E AGATE (ESS DISCONNECT/ PV RAPID SHUTDOWN) SERVICE DISCONNECT Signed 2/27/2025 EQUIPMENT SPECIFICATIONS PV-06 2/26/2025 SHEET TITLE DRAWN DATE DRAWN BY TSD SHEET NUMBER REV DATEDESCRIPTION REVISIONS PROJECT NAME AHJ STAMP APN #: 063010501912 AHJ: CITY OF PORT ANGELES UTILITY: CITY OF PORT ANGELES STEVEN FURRH 210 ORCAS AVE, PORT ANGELES, WA 98362 (360) 640-8618 STEVENFURRH@YAHOO.COM SOLAR MODULE SPECIFICATIONS MANUFACTURER / MODEL #YUKON SERIES SEG-410-BMD-HV VMP 31.05 V IMP 13.21 A VOC 37.32 V ISC 13.80 A TEMP. COEFF. VOC -0.27 %/°C ELECTRICAL STAMP MICROINVERTER SPECIFICATIONS MANUFACTURER / MODEL #HOYMILES HMS-900-2T-NA [240V] INPUT POWER RANGE 360W-600W+ MIN/MAX START VOLTAGE 16V/60V NOMINAL AC VOLTAGE 240V MAX CONT. OUTPUT CURRENT 3.42A MAX CONT. OUTPUT POWER 820W MAX MODULES PER STRING 14 (7 MICROINVERTERS) MICROINVERTER SPECIFICATIONS MANUFACTURER / MODEL #HOYMILES HMS-400-1T-NA [240V] INPUT POWER RANGE 360W-540W+ MIN/MAX START VOLTAGE 16V/60V NOMINAL AC VOLTAGE 240V MAX CONT. OUTPUT CURRENT 1.50 MAX CONT. OUTPUT POWER 360W MAX MODULES PER STRING 16 (16 MICROINVERTERS) Signed 2/27/2025 Description Hoymiles new microinverter HMS-1000 series are suitable for high-powered solar panels, which rank among the highest for 2-in-1 microinverters. Each microinverter can connect up to 2 panels, with independent MPPT and monitoring maximizing the power production of your installation. With a maximum DC voltage of 65 volts, Hoymiles microinverter is a PV Rapid Shutdown Equipment and conforms with NEC-2017 and NEC-2020 Article 690.12 and CEC-2021 Sec 64-218. The new Sub-1G wireless solution enables more stable communication with Hoymiles gateway DTU. 01 Microinverter Datasheet HMS-700-2T-NA HMS-800-2T-NA HMS-900-2T-NA HMS-1000-2T-NA 03 05 Region: North America V202403 © 2024 Hoymiles Power Electronics Inc. All rights reserved hoymiles.com sales@hoymiles.com Features 01 04High-powered microinverter for 2-in-1 series with superior performance Independent MPPT and monitoring ensure greater energy harvest and easier maintenance 02 05 03 06 Safer for rooftop solar stations with PV rapid shutdown compliance With Reactive Power Control, compliant with UL 1741, IEEE 1547, UL 1741 SA, CA Rule21, etc. Sub-1G wireless solution allows stable communication in commercial and industrial settings 2-in-1 design enables faster installation Open Energy For All Technical Specifications © 2024 Hoymiles Power Electronics Inc. All rights reserved. Model HMS-700-2T-NA HMS-800-2T-NA HMS-900-2T-NA HMS-1000-2T-NA Input Data(DC) Commonly used module power (W)280 to 470+320 to 540+360 to 600+400 to 670+ Maximum input voltage (V)60 65 65 65 MPPT voltage range (V)16–60 Start-up voltage (V)22 Maximum input current (A)2 × 11.5 2 × 12.5 2 × 13.3 2 × 14 Maximum input short circuit current (A)2 × 16 2 × 20 2 × 20 2 × 20 Number of MPPTs 2 Number of inputs per MPPT 1 Output Data(AC) Peak output power (VA)700 800 900 1000 Maximum continuous output power (VA)638 720 820 958 Maximum continuous output current (A)2.66 3.07 3.00 3.46 3.42 3.94 3.99 4.61 Nominal output voltage/range (V)1 240/211–264 208/183–228 240/211–264 208/183–228 240/211–264 208/183–228 240/211–264 208/183–228 Nominal frequency/range (Hz)1 60/55–65 Adjustable power factor (@nominal power)> 0.99 default 0.8 leading … 0.8 lagging Total harmonic distortion (@nominal power)< 3% Maximum units per 10 AWG branch2 9 7 8 6 7 6 6 5 Maximum units per 12 AWG branch2 6 5 5 4 4 4 4 3 Efficiency CEC peak efficiency 96.70%96.70%96.50%96.50% Nominal MPPT efficiency 99.8% Night power consumption (mW)< 50 Mechanical Data Ambient temperature range (℉)-40 to +149 (-40℃ to +65℃) Dimensions (W × H × D [inches])10.28 × 7.09 × 1.22 (261 × 180 × 31 mm) Weight (lbs) 6.83 (3.1 kg) Enclosure rating NEMA 6 (Outdoor-IP67) Cooling Natural convection-No fans Features Communication Sub-1G Type of isolation Galvanically Isolated HF Transformer Monitoring Hoymiles S-Miles Cloud (Hoymiles Monitoring Platform) Compliance UL 1741, IEEE 1547, UL 1741 SA, UL 1741 SB (Pending), CA Rule214, CSA C22.2 No. 107.1-16, FCC 15B, FCC 15C PV Rapid Shutdown Conforms with NEC-2017 and NEC-2020 Article 690.12  and CEC-2021 Sec 64-218 Rapid Shutdown of PV Systems. * : Nominal voltage/frequency range can vary depending on local requirements. ** : Refer to local requirements for exact number of microinverters per branch. ***: The HMS-1000-2T-NA microinverter complies with both CA Rule 21 (240 Vac) and CA Rule 21 (208 Vac). Open Energy For All Features Description Hoymiles new microinverter HMS-500 series are suitable for high-powered solar panels, which rank among the highest for 1-in-1 microinverters. Each microinverter can be connected to one panel and used in various applications, making it one of the most flexible solar solutions. With a maximum DC voltage of 65 volts, Hoymiles micro- inverter is a PV Rapid Shutdown Equipment and conforms with NEC-2017, NEC-2020 Article 690.12, and CEC-2021 Sec 64-218. The new Sub-1G wireless solution enables more stable communication with Hoymiles gateway DTU. Microinverter Datasheet HMS-350-1T-NA HMS-400-1T-NA HMS-450-1T-NA HMS-500-1T-NA Region: North America V202310 © 2023 Hoymiles Power Electronics Inc. All rights reserved. hoymiles.com sales@hoymiles.com 01 03 02 04 High-powered microinverter for 1-in-1 series with superior performance Safer for rooftop solar stations with PV rapid shutdown compliance 1-in-1 design enables most flexible applications With Reactive Power Control, compliant with UL 1741, IEEE 1547, UL 1741 SB, etc. Model HMS-350-1T-NA HMS-400-1T-NA HMS-450-1T-NA HMS-500-1T-NA Input Data (DC) Commonly used module power (W)280 to 470+320 to 540+ 360 to 600+400 to 670+ Maximum input voltage (V)60 65 65 65 MPPT voltage range (V)16–60 Start-up voltage (V)22 Maximum input current (A)13 14 15 16 Maximum input short circuit current (A)20 25 25 25 Number of MPPTs 1 Number of inputs per MPPT 1 Output Data (AC) Peak output power (VA)350 400 450 500 Maximum continuous output power (VA)319 360 410 475 Maximum continuous output current (A)1.33 1.53 1.50 1.73 1.71 1.98 1.98 2.28 Nominal output voltage/range (V)1 240/211–264 208/183–228 240/211–264 208/183–228 240/211–264 208/183–228 240/211–264 208/183–228 Nominal frequency/range (Hz)1 60/55–65 Power factor (adjustable)> 0.99 default 0.8 leading … 0.8 lagging Total harmonic distortion < 3% Maximum units per 10 AWG branch2 18 15 16 13 14 12 12 10 Maximum units per 12 AWG branch2 12 10 10 9 9 8 8 7 Efficiency CEC peak efficiency 96.70%96.50% Nominal MPPT efficiency 99.80% Night power consumption (mW)< 50 Mechanical Data Ambient temperature range (℃)-40 to +65 Dimensions (W × H × D [mm])182 × 164 × 30 Weight (kg) 1.75 Enclosure rating Outdoor-IP67 (NEMA6) Cooling Natural convection (no fans) Features Communication Sub-1G Type of isolation Galvanically Isolated HF Transformer Monitoring Hoymiles S-Miles Cloud3 Compliance UL 1741, IEEE 1547, UL 1741 SB, CSA C22.2 No. 107.1-16, CA Rule 21 (240 Vac), FCC 15B, FCC 15C PV Rapid Shutdown Conforms with NEC-2017 and NEC-2020 Article 690.12 and CEC-2021 Sec 64-218 Rapid Shutdown of PV Systems. Technical Specifications © 2023 Hoymiles Power Electronics Inc. All rights reserved. *1 Nominal voltage/frequency range can vary depending on local requirements. *2 Refer to local requirements for exact number of microinverters per branch. *3 Hoymiles Monitoring System 1/2”socket for everything. One clamp for mid or end. No tool splicing and bonding. Easy wire management. Simplicity UL 2703 listed LTR-AE-001-2012 listed Class A fire rating for any slope ASCE 7-16 PE Certified FL Cert of Approval FL41396 Code Compliant Secured on industry-leading Pegasus Mounts, for composite shingle and tile roofs. Backed by a 25-year warranty. Watertight for Life Pegasus Solar Inc | 506 West Ohio Avenue, Richmond, CA 94804 | www.pegasussolar.com A complete system for hassle-free rooftop installation, from watertight mounts to lifetime wire management. Next-Level Solar Mounting The N-S Bonding Jumper bonds row to row with no tools. Instant Bonding The Multi-Clamp works as mid- or end-clamp, and fits standard 30-40mm frames. One Clamp Anywhere Open rail channel holds and protects wires. Clamps won’t pinch wires after tightening. Lifetime Wire Management The narrowest panel gap available. Optional Hidden End Clamps and End Caps provide a flush look on the edge of the array. Premium Aesthetics Connect rails instantly, without tools, interference or limitations. Bonding Structural Splice RAIL SYSTEM RAIL SYSTEM Pegasus Max Rail Multi-Clamp Maximum-strength design. Meets specifications for high snow-load and hurricane zones. Black and Mill finish Fits 30-40mm PV frames, as mid- or end-clamp. Twist-locks into position; doesn’t pinch wires in rail. Bonds modules to rail; UL2703 listed as reusable Installs by hand. Works over mounts. Structurally connects and bonds rails automatically; UL2703 listed as reusable. Dovetail shape for extra strength. Uses ½” socket. Pegasus Rail Available in 14’ and 7’ lengths for easy layout and shipping. Open-channel design holds MC4 connectors, PV wire and trunk cables. Black and Mill finish Pegasus Solar Inc | 506 West Ohio Avenue, Richmond, CA 94804 | www.pegasussolar.com Patents pending. All rights reserved. ©2023 Pegasus Solar Inc. Dovetail T-bolt Splice and Max Splice Ground Lug Offers premium edge appearance. Preinstalled pull-tab grips rail edge, allowing easy, one-hand installation. Tucks away for reuse. Hidden End Clamp Holds 6 or 8 AWG wire. Mounts on top or side of rail. Assembled on MLPE Mount. UL2703 listed as reusable. Hand operable. Holds wires in channel. Won’t slip. Secures four PV wires or two trunk cables. Stainless-steel backing provides durable grip. Eliminates sagging wires. Fits flush to PV module and hides raw or angled cuts. Hidden drain quickly clears water from rail. Secures and bonds most micro-inverters and optimizers to rail. Connectors and wires easily route underneath after installation. UL2703 listed as reusable. End Cap and Max End CapMLPE Mount Cable Grip Wire Clip Installs by hand, eliminates row-to-row copper wire. UL2703 listed as reusable only with Pegasus Rail. N-S Bonding Jumper Quickly calculate the most efficient layout, spans and materials needed to suit your job. Visit the Pegasus Customer Portal. pegasussolar.com/portal Certifications: • UL 2703, Edition 1 • LTR-AE-001-2012 • ASCE 7-16 PE certified • Class A fire rating for any slope roof • FL Cert of Approval FL41396 FREEPEGASUS SOLARDesign Tool For reference only. Spans above are calculated using 7-16 for a Gable Roof, Exposure Category B, 0-20deg roof angle, 30ft mean roof height with non-exposed modules. For PE certified span tables, visit www.pegasussolar.com/spans. SPANLOAD SNOW (psf)WIND (MPH) 0 10 30 32”48”72”96”120” 50 100 120 100 130 140 190 PEGASUS RAIL PEGASUS MAX RAIL • • • • • • • • • • • • • • • • • • • Model Number Battery Chemistry Usable System Energy Aggregate Throughput Real Power (charge) Real Power (discharge) Nominal AC Voltage Coupling Phase Round Trip Efficiency Dimensions (H × W × D) Weight Mounting Cooling aPower X-20 Lithium Iron Phosphate (LFP) 15 kWh per unit, up to 15 units per aGate1 60 MWh 8 kW continuous 10 kW continuous, 15 kW peak for 10 seconds 120 / 208 V, 120 / 240 V, 50 Hz / 60 Hz AC-coupled 2 W+N+PE 90%2 Certifications Seismic Environmental Emissions UL 9540, UL 9540A, UL 1973, UL 1741, UL1741 SB, UL 1741 PCS, IEEE 1547, IEEE 1547.1, UN 38.3, CSA C22.2 No. 107.1:16 AC 156, OSHPD, IEEE 693-2005 (high) California Proposition 65RoHS Directive 2011 / EU FCC Part 15 Class B, ICES 003 45.3 in × 29.5 in × 11.4 in(1150 mm × 750 mm × 290 mm) 357 lb. (162 kg) Wall or floor mount Natural air-cooled design Enclosure Type Operating Temperature Operating Humidity (RH) Altitude Environment Ingress Protection Type 3R IP56 (Wiring) IP67 (Battery Pack & Inverter) -4° F to 130° F (-20° C to 55° C) Up to 100% RH, condensing Maximum 9,843 ft (3,000 m) Indoor and outdoor rated 1.For 120/208V applications, max. 2 aPowers per aGate can be connected in parallel. Please contact us if you have large capacity requirements. 2.At beginning of life, AC to battery to AC, 30% power rating. 3.An ambient temperature of 30°C and a load consumption of 1 kW. Copyright 2024 FranklinWH Energy Storage Inc. All rights reserved. The Franklin logo, FranklinWH, and other trademarks or service names are the trademarks of FranklinWH Energy Storage Inc. The document is for informational purposes only, data subject to change. 2024-09-08 Store solar generated power while the sun is shining. Use the stored energy when needed to lower electric bills. Run heavy loads such as air conditioners and water heaters as usual even during grid outages. Provide homeowner peace of mind by fully charging before severe weather events. PERFORMANCE SPECIFICATIONS MECHANICAL SPECIFICATIONS COMPLIANCE INFORMATION ENVIRONMENTAL SPECIFICATIONS WWW.FRANKLINWH.COM aPower 2 AC-coupled battery 10 kW continuous / 15 kW peak for 10s 8 kW charge power 15 kWh per unit, up to 225 kWh (15 units) per aGate 10,000 battery cycles 60 MWh throughput 45.3 in (1150 mm) 45.3 in (1150 mm) 29.5 in (750 mm) 29.5 in (750 mm) 11.4 in(290 mm) 11.4 in(290 mm) Work Modes Noise Emission User Interface Warranty Self-Consumption Time of Use Emergency Backup 30 dB(A)3 FranklinWH App 15 years Subject: Proposed Solar Panel Installation Steven Furrh Residence, 210 Orcas Ave, Port Angeles, WA To Whom it May Concern, Design Parameter Summary Governing Building Code: 2021 Washington State Residential Code (2021 IRC) Risk Category: II Design Wind Speed: 110 mph (per ASCE 7-16) Snow Load: 25 psf Roof Information Roof Structure: 2x4 Rafters @ 24" O.C. Roofing Material: Asphalt Shingles (1 layer) Roof Slope: 22° Note: Required embedment length excludes the tapered tip of the screw, and embedment into sheathing. Lag Screws: (1) 5/16" diameter min., with min. 2.5" embedment into framing members, at 48" O.C. max, Specifically: 1) the system is designed for the local wind speed; 2) the ground snow load does not exceed 70 psf; 3) the total dead load of all items is less than 4 psf (actual value is approximately2.75 psf); 4) Modules are not mounted more than 18" off the roof; and 5) Supports are installed such that the dead load is spread across roof- framing members and does not exceed 50 lbs at any point. Roof Connection Details Our engineering department has reviewed information, gathered by our field crews, related to the proposed solar panel installation at the above-referenced address. The purpose of our review was to determine the structural adequacy of the existing roof. Based on our review and analysis of the available information, and in accordance with governing building codes, it is our professional opinion that the existing structure is permitted to remain unaltered for the proposed solar installation. Wind uplift on the panels has been calculated in accordance with the relevant provisions of ASCE 7-16. This loading has been used to verify the adequacy of the connection specified above. Connection locations should be in accordance with design drawings. Locations per design drawings February 28, 2025 Analysis The proposed installation complies with the requirements of WAC Section 51-51-03240 R324.4 (Exception) and is therefore deemed adequate to support the load of the rooftop solar system. Sincerely, Trevor A. Jones, P.E. 28/02/2025 Limitations and Disclaimers If you have any questions or concerns, please contact our office at (855)-709-1181, or email Austen.Morfin@purelightpower.com. Electrical engineering and waterproofing are beyond the scope of this analysis. Solar panels must be installed per manufacturer specifications. Structural design and analysis of the adequacy of solar panels, racks, mounts, rails, and other components is performed by each component's respective manufacturer and the undersigned makes no statement of opinion regarding such components. This letter and the opinions expressed herein are rendered solely for the benefit of the permitting authority (city or county building department), and may not be utilized or relied on by any other party. The opinion expressed in this letter is made in reliance on the following assumptions: the existing structure is in good condition; the existing structure is free from defects in design or workmanship; and the existing structure was code-compliant at the time of its design and construction. These assumptions have not been independently verified, and we have relied on representations made by the property owner and his or her agents with respect to the foregoing. The undersigned has not inspected the structure for patent or latent defects. The roof structure need not be altered for either gravity or lateral loading. Therefore, the existing structure is permitted to remain unaltered. Connections to the roof must be made per the "Roof Connection Details" section above. Copies of all relevant calculations are enclosed. Conclusion WA State Exception Criteria - Calculation Connection Demand Spacing perpendicular to rail 32.5 in 1/2 panel length Spacing parallel to rail 48 in Max spacing Solar Dead Load 2.75 psf Solar DL Point Load 29.79166667 lbs OK This calculation justifies the additional solar load by showing the solar dead load at each attachment is less than 50 lbs (WAC 51-51-03240, R324.4, Exception Criteria). Pegasus Comp Mount Connection Calculation Connection Demand Spacing perpendicular to rail 32.5 in 1/2 panel length Roof Angle 22 degrees Roof Layout Hip Wind Speed 110 mph Exposure Coefficient, Kz 0.57 Topographic Factor, Kzt 1 Directionality Factor, Kd 0.85 Elevation Factor, Ke 0.99 Velocity Pressure, qz 16.0 psf Prying Coefficient 1 Zone 1 Zone 2n Zone 3e Spacing parallel to rail 48 48 48 in Max spacing Effective Wind Area on each connection 10.8 10.8 10.8 ft2 GCp (max)1.50 2.46 2.89 Exposed Panels? (γE = 1.5)No No No Pressure Equalization Factor, γa 0.79 0.79 0.79 Uplift Force 18.9 31.0 36.3 psf Max. Uplift Force / Connection (0.6 WL)122.6 201.2 236.3 lbs Solar Dead Load (0.6 DL)17.9 17.9 17.9 lbs Max. Uplift Force (0.6 WL - 0.6 DL)104.8 183.4 218.4 lbs Connection Capacity Pegasus Comp Mount Fastener Type Lag Screw Fastener Diameter 0.3125 in Embedment Length, min 2.5 in Lumber Species & Grade DFL #2 (Assumed) Lumber Specific Gravity 0.5 Nominal Withdrawal Capacity, W 665.0 lbs NDS 12.2-1 # of Screws 1 Load Duration Factor, CD 1.6 Adjusted Withdrawal Capacity, W'1064.0 lbs Compare Adjusted Withdrawal Capacity to ASD Factored Demand Zone 1 Zone 2n Zone 3e O.K.O.K.O.K. This calculation justifies the connection of the solar panels to existing roof members, by showing the connection capacity is equal to or greater than the uplift force demands. ELECTRICAL INSPECTION WIRING REPORT APPROVED NOT APPROVED DITCH ROUGH IN/COVER SERVICE FINAL COMMENTS: NOTIFY INSPECTOR at (360) 808-2613 WHEN CORRECTIONS ARE COMPLETED WITHIN 15 DAYS DATE PERMIT # INSPECTOR 6/2/25 25-359 TAP OWNER CONTRACTOR Solgen Solar PROJECT ADDRESS 210 Orcas Ave