Residence
Structural Design
for
George & Rena Peabody
Delguzzi Drive
Port Angeles, WA 98362
TP# 063012-680140
cv
I EXPIRES ..-4. c C1
4 SEASONS ENGINEERING, INC.
619 SOUTH CHASE STREET
PORT ANGELES, WA 98362
Fllt
4SEASONS
ENGINEERING, INC
(360) 452-3023 · Fax (360) 452-3047
619 S. Chase Street. Port Angeles, WA 98362
May 3, 2007
Jim Lierly
City of Port Angeles Building Official
PO Box 1150
Port Angeles, WA 98362
Subject:
Scope of Engineering for:
Structural Design
George & Rena Peabody
Delguzzi Drive
Port Angeles, WA 98362
Enclosed is the structural design of the Residence for George & Rena Peabody.
At this time, portions of this structure that have been reviewed by the engineer
include:
1. Lateral Forces
2. Beams and Headers
3. Foundation
Please give me a call if you need any additional information.
Sincerely
C0"UJUL-.> 9 (2~ Qs .
Donna J. Petersen P .E.
Structural Design
George & Rena Peabody
Delguzzi Drive
Port Angeles, WA 98362
DESIGN CRITERIA
DESIGN STRESSES
ELEVATION LESS THAN 625 FT
DOUGLAS FIR/LARCH #2- 2 & 4 X
Fb = 900 PSI
Fv= 95 PSI
E= 1.6 (10)6 PSI
SNOW LOAD GROUND= 25 PSF
SNOW ROOF = 25 PSF
LIVE LOAD = 40 PSF (FLOOR)
DEAD LOAD = 10 PSF (FLOOR)
DEAD LOAD = 10 PSF (ROOF)
DEAD LOAD = 7 PSF (CEILING)
DOUGLAS FIR/LARCH #1- 2 & 4 X
Fb= 1200 PSI
Fv= 95 PSI
E= 1.8 (10)6 PSI
WIND SPEED, V FM = 80 MPH
3 SEC GUST, V 35 = 100 MPH
HEM FIR #2- 2 & 4 X
Fb = 850 PSI
Fv= 75 PSI
E= 1.3 (10)6 PSI
GLU-LAM BEAMS 24F-V4
Fb= 2400 PSI (T) BOTTOM
Fb= 1850 PSI (T) TOP
Fv= 165 PSI
E= 1.8 (10)6 PSI
EXPOSURE C
SEISMIC ZONE O2
SOIL BEARING = 1500 PSF
REFERENCES
(1) INTERNATIONAL BUILDING CODE 2006
(2) INTERNATIONAL RESIDENTIAL CODE 2006
(3) MINIMUM DESIGN LOADS FOR BUILDING AND OTHER STRUCTURES ASCE7-05
(4) NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION 2005 (NDS-05)
(5) BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE 2005 (ACI318-05)
(6) BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES 2005 (ACI 530-05)
(7) SPECIFICATIONS FOR STRUCTURAL STEEL BUILDINGS 2005 (ASCE 360)
(8) CONNECTORS FOR WOOD CONSTRUCTION by SIMPSON STRONG-TIE
(9) ROSBORO-APA WOODCAD, VERSION 1.1 by ROSBORO GLULAM RESOURCES 2000
(10) RISA-2D RAPID INTERACTIVE STRUCTURAL ANALYSIS - 2-DIMENSIONAL VERSION 6.5
3
--_..~-.- -.----.....----...------
General Notes
1. Ground snow load = 25 PSF, roof snow load = 25 PSF
2. Maximum soli bearing capacity = 1500 PSF
3. Seismic Zone 02.
4. Wind, VFM = 80 MPH, 3 second gust, V3S = 100 MPH, Exposure "C".
5. Notations on drawing relating to framing clips, joist hangers and other connecting devices refer to catalog numbers of connectors
manufactured by the Simpson Strong-Tie Company, San Leandro, CA. Equivalent devices by other manufacturers may be
substituted, provided they have ICBO approval for equal load capacities.
6. Roof Trusses: Trusses shall be designed by the manufacturer and design calculations shall be submitted for approval prior to
fabrication. Each wood truss shall carry a grading stamp. Top chord members shall be sized to accommodate roof snow load
and appropriate snow drifts as noted In the IBC. No field modification of trusses will be allowed without the engineer's approval.
Live load truss deflection shall be limited to U360. Total load deflection will be limited to U240.
8. Contractor shall provide temporary bracing and shoring for the structure and structural components until all final connections
have been completed In accordance with the plans.
7. Girder trusses shall be attached to wall framing with Simpson LGT2, minimum 2000 pounds uplift, or equal.
9. Contractor shall be responsible for all the required safety precautions and methods, techniques, sequences or procedures
required to perform his work.
10. Contractor Initiated changes shall be submitted in writing to the structural engineer for approval prior to fabrication or
construction.
11. Drawings indicate general and typical details of construction, where conditions are not specifically indicated but are of similar
character to details shown, similar details of construction shall be used.
General Concrete Notes
(The Following apply unless shown on the plans)
1. All materials and workmanship shall conform to the requirements of the drawings, specifications, and the 2006 International
Building Code.
2. Concrete shall attain a 28 day strength of F'e= 2500 psi, 5 1/2 sacks of cement per cubic yard of concrete.
3. Reinforcing steel shall conform to ASTM A615-76A, Grade 40, fy= 40,000 psI.
4. Reinforcing steel shall be detailed (including hooks and bends) In accordance with 30 bar diameters or 2'-0" minimum.
Provide corner bars In all wall Intersections. Lap corner bars 30 bar diameters or 2'-0" minimum.
5. Lap adjacent mats of welded wire mesh one full mesh at sides and ends.
6. No bars partially embedded In hardened concrete shall be field bent unless specifically so detailed or approved by the
structural engineer.
7. Concrete protection (cover) for reinforcing steel shall be as follows:
Footings and other unformed surfaces:
earth face 3"
Formed surfaces exposed to earth, walls below ground, or weather:
#6 bars or larger 2"
#5 bars or smaller 1-1/2"
Walls interior face 3/4"
9. Concrete slabs in living spaces shall be 4 inches thick minimum, with 6x6, 10 ga W.W.M. over 2" clean damp sand, over 6 mil
vapor barrier, over 4" crushed rock, over compacted subgrade.
8. Footings shall bear on solid unyielding natural earth free of organic materlal12" below original grade.
10. Other concrete slabs shall be 4 inches thick minimum, with 6x6, 10 ga W.W.M. over 4" crushed rock, over compacted
subgrade.
/1
Wood Framing Notes
(The Following apply unless shown on the plans)
1. All wood framing details not shown otherwise shall be constructed equal to or better than the minimum standards of the 2006
IBC.
2. Minimum nailing requirements: Unless otherwise noted, minimum nailing shall be in accordance with Table 2304.9.1 of the
2006 IBC
3. All structural framing lumber such as 2x_jolsts, and rafters to be Douglas Fir No.2, Spruce/Pine/Fir No.2, or Hem/Fir No.2 kiln
dried.
4. All 2x_ studs and blocking to be Douglas Fir construction, Spruce/Pine/Fir construction, or Hem/Fir construction grade.
5. All structural posts to be Douglas Fir No.2.
6. All structural headers to be 4x_ Douglas Fir No.2.
8. All 2x framing lumber exposed to weather, and/or moisture shall be Hem-Fir No.2, pressure treated In accordance with the
American Wood Preservers Association standard for above ground use.
7. All Glu-Iam beams to consist of Douglas Fir kiln dried 24F-V4 standard grade unless noted otherwise on plans.
9. All 4x and 6x structural lumber exposed to weather, and/or in ground contact shall be Hem-Fir No.2, pressure treated In
accordance with the American Wood Preservers Association standard for ground contact use.
10. Framing connectors, nails, bolts, and other fasteners In contact with pressure treated wood shall have the following finishes:
Wood Treatment Finish
CCA-C and DOT Sodium Borate ISBXl Galvanized, 0.60 ozl~
ACQ-C, ACQ-D, CBA-A, CA-B, Other Borate (Non- Post Hot-Dip Galvanized, ZMAX galvanized, 1.85
DOTI ozlft2. , or SST300-Stalnless Steel
Steel Ammoniacal Copper Zinc Arsenate (ACZE) SST300-Stalnless Steel
and other Dressure treated woods.
11. When using Stainless Steel or hot-dip galvanized connectors, the connectors and fasteners should be made of the same
material. Stainless Steel fasteners shall not be use In applications where contact with Galvanized and Post Hot-Dip Galvanized
metals will occur.
13. All columns in framed walls to be well nailed Into adjacent framing in order to resist lateral movement.
12. Individual members of built-up posts and beams shall each be attached with 16d spikes at 12" o.c. staggered.
14. Provide solid blocking for wood columns and multiple studs through floors to supports below.
15. Provide 4x10 headers, or double 2x10 headers over and one trimmer and one king stud each side of all openings 5 feet or less
In width in stud bearing walls not detailed otherwise.
16. Provide 4x10 headers, or double 2x10 headers over and two trimmers and one king stud each side of all openings greater than
5 feet in width In stud bearing walls not detailed otherwise.
17. Provide 4x8 headers, or double 2x8 headers over and double studs each side of all openings In non-structural stud walls not
detailed otherwise.
18. At joist areas: Provide solid blocking at bearing points and at intermediate bearing locations. Provide double joists under all
load bearing partitions. Provide double joists each side of openings unless detailed otherwise.
20. Toenail joists to supports with 2-16d nalls, 2-10d box nails for T JI joists.
19. Provide double joist headers and double joists each side of all openings In floors and roofs unless detailed otherwise.
22. All wood stud walls shall have lower wood plate attached to wood framing below with 16d nails at 12" o.c. staggered, unless
otherwise noted In the shearwall schedule.
21. Attach joists to flush headers and beams with Simpson "U" series metal joist hangers to suit the joist size.
23. Plywood roof and floor sheathing unless otherwise noted on plan shall be laid up with face grain perpendicular to supports
and nailed with 8d nails @ 6" O.c. to framed panel edges and over stud walls shown on the plans @ 12" O.c. to Intermediate
supports. Provide approved plywood clips @ 16" o.c. at unblocked roof sheathing edges. Provide solid blocking at lines of
support at floors. Toenail blocking to supports with 16d @ 12" o.c., unless otherwise noted In the shearwall schedule.
25. Plywood wall sheathing for noted shear walls shall have solid blocking at all sheathing panel edges. See shear wall schedule
for further notes.
24. Provide continuous solid blocking at mid-height of all stud walls over 10' in height unless wall Is blocked per shear wall note.
-.----.-----.-.- _.
SHEAR WALL SCHEDULE 1 7
Mark Sheeting Fastener spacing Intermediate Framing Bottom plate nailing 8i Anchor Bolts l.(aJClumum I NoTes
doubled stud snllclnn allowble
o all edges framing noli backing Sheeted Sheeted Sheeted Sheeted shear
(Blocked) spacing size one sldtl both sides one sldtl both sldtls
7/16.0SB 8d 0 6. OC 8d 0 6. OC 2x 240 PLF 2, .3, 6
0 OR for stud framing 024" 2-16d 0 2-16d 0 1/2" Xl0" 5/8" Xl0" 480 PLF
8d 0 12" OC
15 GA 04" OC for stud framln 016" 12"OC 8.OC 048" O.C. o .30" O. C.
7/16.0SB 8d 04. OC 8d06 OC 2x .350 PLF 2, .3, 5, 6
OR for stud framing 024" 2-16d 2-16d 0 5/8. Xl0. 5/8. Xl0. 700 PLF
0 8d 0 12" OC
15 GA 0.3. OC for stud famlng 016. o 10"OC S"OC 040" O.C. 020" O.C.
1/2" CDX 8d 0 .3" OC 8d 06. OC .3x 490 PLF 2, .3, 4, 5, 6
0 plywood OR for stud framing 024" or 2-16d 2-16d 0 5/8. Xl0. 5/8" Xl0" 980 PLF
8d 0 12" OC
15 GA 02-1/2" OC for stud framIng 0 16" DBL2x o 7.0C .3-1/2.0C 028.0.C. o 14" O.C.
1/2" CDX 10d 0.3" OC 10d 06" OC .3x 600 PLF 2, .3, 4, 5, 6
0 plywood for stud framIng 024" or 2-16d 2-16d 0 5/8. Xl0" 5/8" Xl0. 1200 PLF
10d 0 12" OC DBL2x o 6.OC .3.0C 024.0.C. 012.0.C.
for stud framIng 0 16"
1/2. CDX 10d 02. OC 10d 06" OC .3x 770 PLF 2, .3, 5, 6
(]) plywood for stud framing 024" 'or .3-16d .3-16d 0 5/8. Xl0. SIB. Xl0. 1540 PLF
10d 0 12. OC DBL2x o 6"OC .3.OC o lB. O.C. 09" O.C.
for stud framing 0 16"
0 1/2. GWB Sd COOLER 0 4" OC 5d cooler 04" OC 2x 2-16d 0 5/8" Xl0" .300 PLF .3, 6
both sides OR OR
SdGWB04"OC Sd GWB 04" OC 12.0C o 4B" O.C.
0 ~GWB 6d COOLER 0 .jF OC 6d cooler 04" DC 2x 2-16d 0 S/B" Xl0. .375 PLF .3, 6
both sides OR OR
6d GWB 04. OC 6d GWB 04. OC 10.0C 0.36.0.C.
Notes:
1. ALL NAILS SHALL BE GALVANIZf:D BOX NAILS OR COMMON NAILS, FAS7ERNERS SHAL/.,.MEET THE fQJ..LOWlNG CRI7ERIA:
Bd common -0.1.31.dla X 2-1/2.mln. Sd cooler -0.OB"6 dla X 1-5,.8 min.
. . Sd GWB -0.OB6 dla X 1-5/8 min.
10d common -.0.148 dla X: mIn. 6d cooler -0.092"dla X 1-7/B" mIn.
8d box -0. l1.3"dlo X 2-;:1/2 min. 6d GWB -0.092.dla X 1-7/B. mIn.
10 box -0.12B dla X .3 mIn. 16d common -0.162.dla X .3-1/2. min.
15 GA. staple =0.072.dla X 1-1/2" min.
PROVIDE APA RA TED SHEA THING PL YWOoo OR 058 APA RA TED SIDING .30.3 OF INNER SEAL OSB RA TED PANEL SIDING ON ALL
2. EX7ERIOR WALLS AND NAIL PER N07E 1.
SPECIFIED SHEA THING AND SIDING PANEL EDGES SHALL BE BACKED WITH 2" OR .3" FRAMING (PER THE TABLE) INCLUDING
J. FOUNDATION SILL PLA7ES, VERTICAL FRAMING, AND BLOCKING. PANELS MAY BE INSTALLED EITHER HORIZON TALL Y OR
VERTlCALL Y (SEE N07E 4 FOR EXCEPTION). NAILS SHALL BE STAGGERED FOR J" FRAMING.
7/16.058 MAY BE SUBSTlTU7ED FOR 1/2" CDX PLYWOOD IF FRAMING IS SPACED AT 16" ON CEN7ER, OR PANELS ARE APPLIED
4. WITH LONG DIMENSION ACROSS STUDS FOR FRAMING SPACED AT 24" (BLOCKED).
!tHERE PANELS ARE APPLIED ON BOTH FACES OF A WALL AND NAIL SPACING IS LESS THAN 6 INCHES ON CEN7ER ON EITHER
5. SIDE, PANEL JOINTS SHALL BE OFFSET TO FALL ON DIFffRENT FRAMING MEMBERS OR FRAMING SHALL BE J-INCH NOMINAL AND
NAILS ON EACH SIDE SHALL BE STAGGERf:D.
6. NAILS TO BE DRIVEN flUSH WITH SHEA THING. DO NOT OVER DRIVE NAILS.
7. ALL SHEAR PANELS SHALL BE BLOCKED.
PEA BOD Y
SHEAR WALL
NOTES
4SEASONS
ENG/NEER/N~ /NG. (J60) 452-J02J
619 S. Chase St. Port Angeles. WA 98362
DA TE: MA Y 2007
SCALE: NONE
DRAWN BY: DJP
CHECKED:
SHEET: LR
Residence
George & Rena Peabody
Delguzzi Dr.
Port Angeles, WA 98362
2006 IBC WIND ANALYSIS WIDTH LENGTH LEAST DIM P06 IBC SEISMIC ANALYSIS - SIMPLIFIED BASE SHEP
BUILDING DESCRIPTION .65 .,.., 58 58 S1 0.50
FIRST FLOOR = '10 Ss 1.25
SECOND FLOOR = ':.0' ..' ...... SITE CLASS 0
Y, ROOF HEIGHT = 8 Fv 1.50
AVERAGE HEIGHT OF BUILDING 18 Fa 1.00
A 5.8 3 5.8 2A=f 11.6 Sm1 0.75
WIND EXPOSURE C Sms 1.25
WIND SPEED 100 MPH Sd1 0.50
ROOF PITCH = 10 12 39.81 Sds 0.83
.'
P s = AlwPs30 SEISMIC USE GROUP 1
SEISMIC DESIGN CATEGORY 0
P s = AlwPs30 A= 'w= LC1, Ps30 = LC1,Ps = LC2,Ps3o = LC2,Ps = RESPONSE MODIFICATION FACTOR 61/2
AREA A, PS30 = 1.26 1 17.8 22.39 17.8 22.39 SEISMIC BASE SHEAR COEFFICIENT= 0.154
AREA B, ps30 = 1.26 1 12.2 15.35 12.2 15.35 CONNECTION OF SMALL ELEMENTS
AREA C, ps30 = 1.26 1 14.2 17.86 14.2 17.86 SHEAR COEFFICIENT= 0.111
AREA 0, ps30 = 1.26 1 9.8 12.33 9.8 12.33 HORIZONTAL DIAPHRAGMS
AREA E, ps30 = 1.26 1 1.4 1.76 6.9 8.68 SHEAR COEFFICIENT= 0.1667
AREA F, ps30 = 1.26 1 -10.8 -13.59 -5.3 -6.67 BEARING AND SHEAR WALL
AREA G, ps30 = 1.26 1 0.5 0.63 5.9 7.42 OUT OF PLANE WALL FORCES
AREA H, ps30 = 1.26 1 -9.3 -11.70 -3.8 -4.78 SHEAR COEFFICIENT= 0.3333
E oh 1.26 1 -6.3 -7.92 -6.3 -7.92 MASONRY AND CONCRETE OUT OF PLANE
G oh 1.26 1 -7.2 -9.06 -7.2 -9.06 SHEAR COEFFICIENT= T 0.6667
COMPONENTS AREA 88
ZONE 1, 50sqft 1.26 1 -15.9 -20.00 -10.00 -148.011 LONGEST TRUSS @ 2 FT OC 38
ZONE 2, 50 sqft 1.26 1 -18.9 -23.77 -13.77 -319.567 EAVES 3
ZONE 3, 50sqft 1.26 1 ;;-18.9 -23.77 -13.77 ROOF DEAD LOAD 10
EAVES Z3 1.26 1 ~28.4 -35.72 -25.72 -154.347 TRUSS UPLIFT 622
HURRICANE CLIP H10
'1
-~-----._-.-._--.~--"-_._--._--
Residence
George & Rena Peabody
Delguzzi Dr.
Port Angeles, WA 98362
LATERAL FORCE RESISTING SYSTEM - WIND LOADS SEISMIC LOADS
(AREA)(PRESSURE)/LENGTH = SHEAR
WALL TRIB WIDTH HEIGHT PS FORCE LENGTH SHEAR TRIB WIDTH DL SHEAR SHEAR SHEAR
SECOND AREA FT. FT. PSF LBS FT PLF AREA FT. PSF COEFF. LBS PLF
WALL A A 'Cc,il-cn"t% 1i{';,~.5 ,,' 22.39 ROOF 12.5 17
B '8:0 8.3. 15.35 FLOOR
C 4.5 ,iCc,,4"5" 17.86 WALL ,9,5 ,....40
D ," 5 5, ~'n',Y".. 12.33 2749.5 42.3 ETC. ',",. 0,154 5925.0 91.2
,.,,,t,, ,'"
WALL B A "'...",...> ;::i ')(""""';.;;,'" 22.39 ROOF 26:5' 17
B .. ""'),' 15.35 FLOOR h..;::'
C :26:5 5,0.".."", 17.86 WALL I: 9.5 8
D 1,;\26.5.. ...' ;';,;;16.0: 12.33 7593.6 ".F'iI65"'."., 116.8 ETC. c 0.154 5265.0 81,0
WALL C A 8.0 .."5.0'" 22.39 ROOF .15;3'('\' 17
B 8.0. 8.0 15.35 FLOOR ....':'
C 11.0 5:0 17.86 WALL 9:5 40
D 11.0 8.0 12.33 3945.0 ..."..'65,:,' 60.7 ETC. , .. ,.' 0.154 6401.0 98.5
WALL D A 8.0 4:5 22,39 ROOF 14.0 17
B 8.0 8.0 15.35 FLOOR
C 6,0 4.5 17.86 WALL 9.0 8
D 7;0 8.0 . 12.33 2960.9 52. 56.9 ETC. 0.154 2480.0 47,7
"
WALL E A ':' . " 22.39 ROOF 22.5 17
'.
B 15.35 FLOOR ,..
.. ,...... .r
C I," '22.5, I'. ",,"5.0 c... ,c, 17.86 WALL ,10.0 8
D '22;5< 1:,2" 16:0C .Cc." 12.33 6447.4 c'C 113.1 ETC. 0.154 4055.8 71,2
,'c,
WALL F A u"' ,...... .'" 'Y""C 22.39 ROOF 18.5 17
B 15.35 FLOOR '.
C 18.5 5.0 17.86 WALL 10.0 8
D 18.5, .... 16.0 12.33 5301.2 'S'h. 44'/i 119.1 ETC. 0.154 2700.8 60.7
WALL G A 8.0 A'. 5 22,39 ROOF 10:0 17
B 8.0 I 8.0 15.35 FLOOR .
C 2.0 u 4:5 17.86 WALL .9.0 8
0 3.0 8.0 12.33 2244.9 'Co,. 39.25' . 57.2 ETC. ."c, Ic 0.154 1461.3 37.2
p.
r---
>- N
U <D
.8 C">
III (X)
<Il m
a. ~
III
C ui
<Il ci
0: <Il
~ o/l a;
C <Il 'S Ol
<Il C
U e> :J <l:
'ijj 0 0) t::
<Il <Il a; 0
0: 0 0 a.
_..~--~--~---_..,--_._--_.~_._._-
a a a a 0 a a a a 0 a a a a 0 a a a
C'S ~ ~ ~ C'S C'S ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ C'S ~
() () () ~ () () <Il () () () () () <Il () () () <Il
l- I- l- I- l- I- l- I- l- I- Iii l- I- l- I- I- Iii
w en en en en en en en en en c en en en en c en en en c
0 0 0
i= ~ ~ ~ ~ ~ ~ ~ ~ ~ c ~ ~ :; ~ ~ c ~ ~ ~ ~ c
Z
~
0
0 ~ ~ ~ ~ ~ ~ ~ ~ ~ <Il ~ ~ ~ ~ ~ <Il ~ ~ ~ ~ <Il
..J ::::l ::::l ::::l ::::l ::::l ::::l ::::l ::::l ::::l ::::l ::::l ::::l ::::l ::::l ::::l ::::l ::::l ::::l
0 0 0 0 0 0 0 0 0 0 c 0 0 0 0 0 c 0 0 0 0 c
0 0 0
:r :r :r :r :r :r :r :r :r :r c :r :r :r :r :r c :r :r :r :r c
5 II) ... ... II) 0 lD ... .., .., 01 0 Q) lD lD Q) "'": 0 0 '<I; .., ..... 0
... I- en en oci ..; ui ~ ,..: ,..: ,..: c:i N c:i c:i en ... c:i c:i ... N N c:i
a: LL ui "'l' "'l' ... .., ..... .., .., II) ... lD Q) II) Q) .., m .., m
0 ::i 10 N N N "'l' .., N N N 0 Q) 01 Q) lD ... ... en 0 (X)
a. N N N N N N N N N ... ... N N .., .., N N ....
0 ::::l ..J
..J
~ i;t:" a: '.X "" ~'i .
0 ... 10
LL 0 t liLY
0 it: 0 !,"" &'
0 ., I- ..J I;..' 'iy.' ..,i: li.d I FA: ",",N L16i !
LL
~ >
..J "&;;" I.. " ;',. :l?f F"A .... " I;~ i .
0 10 LL ..~; ,\ ;~~
0 t It) .m It) It) It)
..J it: N .N .'A ...f)j oci N NN c:i N N ..... N It)
..J 0 oci ..... oci
~I'; I- a: '..... i,,' :;"' .... .... ; ....
.... ,2/,\ V ..... i"
a: ..J W
~ ..J
~ a. .., .., .., .., .., "'l' N N N ... ... ... "'l' N "'l' ... ... ... .... ... ...
:r ~
III
Z a: ..... N '"
0 ~ LL It) ~ ~ It) (X) .... ,...., ,...., N .... .... ..... .... <0 N N M a
in ..J oci <D <D oci N ;! M M Iii ..; oci oci ..; ..j en N oci oci c:i c:i ,....:
w :r a. "'l' ~ ~ ~ (X) It) <D <D ..... M m ..... <D M M (X) (X) ~
0 III "'l' M It) M .., N .... .... .... It) N It) N N .... ....
W I-
0 Z
Z w a:
~ ,. 0 0 a a a a a 0 0 0 a a a M 0 m ..... 0 0 0 0 .....
l- I- C! C! C! C! C! C! C! C! C! C! C! C! (X) C! It) (X) C! C! C! C! m
III III 0 .... .... .... .... .... .... .... .... .... .... .... .... c:i .... c:i c:i .... .... .... .... c:i
in ::::l <l:
..... LL
W 0
a: <l:
ci I
..J :r <+ f' ., I;)
..J I-
::::l :r 0 00 0 8. Q 1<; IQ 0 0 0 1"-0 .... (X) 0 0 0 0 0
LL III C! C!.C! .S! 0 C! C! ..... C! "'l' (X) C! C! C! C! m
LL I- .... r .... .... .... I~ Itf 1:'-; ,,~ .... .... c:i .... c:i 0' .... .... .... .... c:i
0 :r t,' ....
"i!. Cl \... if? Ibi.
W J.
:r ,nY '."
..J
..J I-
~ :r
Cl 0 0 0 0 0 a 0 0 (X) 0 0 0 M 0 ~ "'l' 0 0 0 0 ~
LL W N <D ..... ..... "'l'
0 :r
"i!.
z Cl " ..." ';"ii ',<, I:-}.'
Z ~ ;'} j>J
Cl Z i.J .
in !!:. 19 li;~ !~ .
w ;; .~
w a. I- 0 0" 0 0 0 '~ <0 0 ..... ..... 0 0 6 0 "'l'
0 0 :r hi'; ....... 1<, ;; oci
..J Cl ':.;' 5~ 1;\; Iii "!.{i'
..J ~ W liii '",; I..,K ;i Ii;;
~ ,. :r ...i ,0{ co'", I..': ..
0: :r N N N N M It) "': N ..., > ,.,
Il5 a: l- '. .'co', N .....
W 0 ~ :!'IX'i ,;.... ..j
:r ii: ~ LL i . ,is
III ,.
01- f.
r- ::::l I- ~;;~
W ,.
I- :r ~';"
~ Z Cl ~ ..... ..... ..... ..... <D .....
i w LL ,.1,,<1 < 10',
0 :r ,
LL ,
a: :r It) N N N ',.[;iT It) . ~ It) It) It) ~ It) .., It) N ~'" ..... ..... It) It) It) <D It) It)
W <D 'i,! :!;::I~ N ;C- <D ~ ..... <D .... N It) It) ~ ..j .... N N
a. I- ~ ..j 1"'< Iii en .~
..J 0 ".i I ;iN \.7,. . ~
LL 1<:'7') ii ';; .... M
..J ~ .,,'; .,.... <" "j ..
~ ,s. ", ,.ii,' I,
- - W I-
> :r ~ It) It) It)
0 Cl m m m 0 0 m m m m m 0 m m 0 0 m m m
W LL .... .... .... ai ai ai .... ....
:r
0 a:
i ~ LL ~ N N N N N N N N ..... C! M M M It) It) .... <0 ..... ..... ~ 0 0 ..... <D <D N N
III ..J C;; Iii Iii Iii Iii Iii Iii Iii Iii ..; .... <Xi <Xi <Xi <Xi oci ..j c:i ,....: ,....: ;:: <Xi <Xi c:i <Xi <Xi ,....: ,....:
W :r a. It) It) It) It) It) It) It) It) (X) (X) ~ ~ ~ m gj m N ~ ~ 0 0 <D N N M M
N N N N N N N N .... N .... N N .... ....
III III
0 0: ~ ~ ~ ~ ~ ~ ~ ~ (X) ~ ~ ~ <D ~ .... <D <D .... ~ ~
Il5 LL M M ..... M m m N N
Z ..J N <Xi <Xi <Xi <Xi <Xi <Xi <Xi <Xi Iii oci <Xi <Xi <Xi c:i ai ;,0 ;! <Xi <Xi ..; c:i c:i ai N N ,....: lti
~ :r a. ~ .... .... .... .... .... .... .... .... (X) :: N N N <D M It) It) .... M M .... It) It) It)
III .... .... .... .... .... .... .... N N N .... .... .... M M .... N N
..J uJ
..J Z <l: al () 0 W LL Cl :r - <l: al () <l: al () <l: <l: al <l: al <l:
~~
0 <l: al () 0 W LL (!)
a; Z ..J ..J ..J ..J ..J ..J ..J
> 0 ..J ..J ..J ..J ..J ..J ..J
<Il () ~ ~ ~ ~ ~ ~ ~
..J W
III
C)
~._"-'-~-----~._._-------~-_._.-
.1 ; i
I ' :
. .'. I .: ,
I ~aron~'-(( L"YTC;L
j ; ~'P Q.-.y-,' \ U1
--.--: --.--..--.--.-...'.-1...........-..... .-.. ....-.....--....."j-. .....,..
I '09 10 fJc'JI~
I .., I
I . I :
: I , ~ i I .. ~ \ 0 2 40 f-t ~ \b~
I I~'~n~ I . .
I . I
--,--..--~..-..._.---...--.. ....--.,--.--... .... ...--1. ...
I : J. I i
, . I 0 "J/-Jl . :
'.. .. 7-: '::"'1 ' :..J 4 \ fj\
.. (#OD . i
I
-~-l-A",_QL1-~~ in qk,.. . ...
; I ! !
i' I
i !
.. I I VfJE:
'''.... ~~----.".- -I.... ,.,
i I
I I
I I . \ :
. iq~1n f..p ;
--+b3"'f--IA e'PGF "1\. (o0>&, 'rQ 'u
. I; . I 1
I M ~I~.~D ~t'lb~
'I I
, .. I I
_.._._A::L~.J&:g_'TL .......G( l\,(g~)(i ~) 4- .
I~ g: '\ M .~ 1:'i ~ ~4 (:2 c~ C,16)~":' ( ~ \ 0 ~\) 4
Ii,
I . i
i :
I. I \ :
--.-:,-.-.i-s?.o+~(~--... ...C\.....
.. I
r t . ~
: 'I \D ~1\A\o\.JlJF
i, ,
! i i
: b.. . i Q ( UrOr..~ :~ \ (;) g ILo{}t;; .~ D \ \ €? D ; n
. ""~ :
..............-.1.........-... ......". .... ..
. . I 4':
; A 1 ~~ ~~..fi i :.
I ..
I 3 ~ Lt- f 'J. I
! .
i
4\0
140 ~ -f---~
f 1 ?J,~I
[)
~
N
N
o
.)
N
N
;
L C\ 'I. iL\ X \/z.
Irl..t,
~ 'f,. A.. )\ 1.1.\ fl.
0\ 04~
j V"""\ -< 0 \ D ~
ol'-
t-'\ ~ \-4 \ CZ ~'t, \b?
U~ ~';.4~Ve ).i,_
I 4SEASONS - 4- 0'1
DATE; - -
I
?~odj SCALE,
DRAWN BY;
ENGINEERING, INC (360) 452-3023 CHECKED:
619 S. Chase St., Port Angeles, WA 98362 SHEET (,; OF
5 (i\\, wCocP )(\0 ~ ~f-_
igI4IL~1-4'C:;); l\i~~;J ..
i
I
,00'3 -< 0.(6 \f~\
o~
AISC ASD 9th Ed. Code Check
Max Bending Check 0.000
Location 0 ft
Equation H1~
Slender (Qs= 1 , Qa= 1)
Fy 36 ksi
Fa 2.954 ksi
Ft 21.6 ksi
Fb NA
Fv 14.4 ksi
Cb 1
Beam: M1
Shape:
Material:
Length:
I Joint:
J Joint:
LC 1:
Code Check: 0.041 (shear)
Report Based On 97 Sections
L9X4X8
A36 Gr.36
16 ft
N1
N2
fa
16.185 at 8 ft
fc
15.318at8ft
ft
A
Ib
2200 at 0 ft
ksi
Ib
v
-2200 at 16 ft
M
ksi
k-ft
-1 0 at 8 ft
ksi
D~in
-.299 at 8 ft
Max Shear Check 0.041
Location 0 ft
Max Defl Ratio L/642
Out Plane
In Plane
1
16 ft
224.824
No
Cm
Lb 16 ft
KL/r 224.824
Sway No
L Comp Flange 16 ft
\\
01 garage header 16'.Roof Beam
4 Seasons Engineering Inc.
Project: DELGUZZI DR
Job: PEABODY
Client: PEABODY
Page 1
09:16:3005/04/07
Designed by: Donna Petersen P.E.
Checked by:
Input Data
Left Cantilever: None
Check for repetitive use? Yes
Dead Load: 17 psf
Allow. LL Deflection: U240
Eb: 1800000 psi
Main Span: 16'6"
Tributary Width: 2'
Live Load: 0 psf
Allow. TL Deflection: U180
Fv: 240 psi
Right Cantilever: None
Slope: 0:12
Snow Load: 25 psf
DOL: 1.150
Fb: 2400 psi
User Defined Loads
Dead
Uniform
0'
16'6"
100
Design Checks
Max. Value
Allowable
% of Allow.
Location
1518
3047.08
50 tI
0'
1001.88
2760
36 tI
8'3"
53.624
276
19 tI
15'6"
-0.1029
0.825
12 tI
8'3"
-0.3788
1.1
34 tI
8'3"
Reactions and Bearing
0'
16'6"
1.5
1.5
1518
1518
Self-weight of member is not included.
Member has an actuaVallowable ratio in span 1 of 36 tI %.
Design is governed by bending fb/Fb.
Governing load combination is Dead+Snow Condition 1 w/Pattern Loads.
Maximum hanger forces: 1518 Ib (Left) and 1518 Ib (Right).
Program Version 8.2 - 1211712004
\'1-
02 garage header 61.Roof Beam
4 Seasons Engineering Inc.
Project: DELGUZZI DR
Job: PEABODY
Client: PEABODY
Page 1
09: 18:41 05/04/07
Designed by: Donna Petersen P.E.
Checked by:
Input Data
Left Cantilever: None
Check for repetitive use? Yes
Dead Load: 17 psf
Allow. LL Deflection: U240
Eb: 1600000 psi
Main Span: 6'6"
Tributary Width: 5'
Live Load: 0 psf
Allow. TL Deflection: U180
Fv: 180 psi
Right Cantilever: None
Slope: 0:12
Snow Load: 25 psf
DOL: 1.150
Fb: 900 psi
User Defined Loads
Dead
Uniform
0'
16'6"
100
Design Checks
Max. Value
Allowable
% of Allow.
Location
1007.5
3281.47
31 tI
0'
393.622
1242
32 tI
3'3"
36.285
207
18 tI
9-1/4"
-0.0136
0.325
4t1
3'3"
-0.0337
0.4333
7t1
3'3"
Reactions and Bearing
0'
6'6"
1.5
1.5
1007.5
1007.5
Self-weight of member is not included.
Member has an actual/allowable ratio in span 1 of 32 tI %.
Design is governed by bending fb/Fb.
Governing load combination is Dead+Snow Condition 1 w/Pattern Loads.
Maximum hanger forces: 1007.51b (Left) and 1007.5 Ib (Right).
Program Version 8.2 - 12/17/2004
\~
4 Seasons Engineering Inc.
Project: DELGUZZI DR
Job: PEABODY
Client: PEABODY
03 breakfast header 9--Roof Beam
Page 1
09:37:36 05/04/07
Designed by: Donna Petersen P.E.
Checked by:
Input Data
Left Cantilever: None
Check for repetitive use? Yes
Dead Load: 17 psf
Allow. LL Deflection: U240
Eb: 1600000 psi
Main Span: 9'6"
Tributary Width: 2'
Live Load: 0 psf
Allow. TL Deflection: L/180
Fv: 180 psi
Right Cantilever: None
Slope: 0:12
Snow Load: 25 psf
DOL: 1.150
Fb: 900 psi
User Defined Loads
Dead
Uniform
O'
16'6"
100
Design Checks
Max. Value
Allowable
% of Allow.
Location
874
3281.47
27 tI
0'
499.064
1428.3
35 tI
4'9"
34.171
207
17 tI
9-1/4"
-0.0248
0.475
5t1
4'9"
-0.0913
0.6333
14 tI
4'9"
Reactions and Bearing
0'
9'6"
1.5
1.5
874
874
Self-weight of member is not included.
Member has an actual/allowable ratio in span 1 of 35"%.
Design is governed by bending fb/Fb.
Governing load combination is Dead+Snow Condition 1 w/Pattern Loads.
Maximum hanger forces: 874 Ib (Left) and 874 Ib (Right).
Program Version 8.2 - 12/1712004
\4-
04 master bedroom header 9'.Roof Beam
4 Seasons Engineering Inc.
Project: DELGUZZI DR
Job: PEABODY
Client: PEABODY
Page 1
10: 1 0:59 05/04/07
Designed by: Donna Petersen P.E.
Checked by:
Input Data
1P"\l:i9rrMfi~8Jlx; ~~!
Left Cantilever: None
Check for repetitive use? Yes
Dead Load: 17 psf
Allow. LL Deflection: U240
Eb: 1800000 psi
Right Cantilever: None
Slope: 0:12
Snow Load: 25 psf
DOL: 1.150
Fb: 2400 psi
User Defined Loads
Dead
Dead
Snow Condition 1
Dead
Snow Condition 1
Uniform
Concentrated
Concentrated
Uniform
Uniform
0'
5'
5'
5'
5'
5'
5'
100
1334.5
1963
300
441
Design Checks
Max. Value
Allowable
% of Allow.
Location
5154.28
5206.54
99 tI
9'6"
2227.61
2760
81 tI
5'1-1/8"
169.693
276
61 tI
8'6"
-0.1318
0.475
27 tI
4'11"
-0.2439
0.6333
38 tI
4'11 "
Reactions and Bearing
0'
9'6"
1.604
2.563
3225.72
5154.28
Self-weight of member is not included.
Member has an actual/allowable ratio in span 1 of 81 tI %.
Design is governed by bending fb/Fb.
Governing load combination is Dead+Snow Condition 1 w/Pattern Loads.
Maximum hanger forces: 3225.72 Ib (Left) and 5154.28 Ib (Right).
Program Version 8.2 - 1211712004
\~
05 patio beam-Roof Beam
4 Seasons Engineering Inc.
Project: DELGUZZI DR
Job: PEABODY
Client: PEABODY
Page 1
10:37:5205/04/07
Designed by: Donna Petersen P.E.
Checked by:
Input Data
Left Cantilever: None
Main Span: 10'
Main Span: 10'
Tributary Width: 3'6"
Live Load: 0 psf
Allow. TL Deflection: U180
Fv: 170 psi
Right Cantilever: None
Slope: 0:12
Snow Load: 25 psf
DOL: 1.150
Fb: 875 psi
Check for repetitive use? Yes
Dead Load: 17 psf
Allow. LL Deflection: U240
Eb: 1300000 psi
User Defined Loads
Dead
Unifonn
0'
20'
100
Design Checks
Max. Value
Allowable
% of Allow.
Location
3087.5
5156.59
60 et
10'
-718.545
1000.93
72et
10'
50.546
195.5
26 et
9'4-1/2"
-0.0548
0.5
10 tf
4'5-7/32"
-0.114
0.6667
17 et
4'5-7/32"
Reactions and Bearing
O'
10'
20'
1.5
1.5
1.5
980.938
3087.5
980.938
Self-weight of member is not included.
Member has an actuaVallowable ratio in span 1 of 72 et %.
Design is governed by bending fb/Fb.
Governing load combination is Dead+Snow Condition 1 w/Paltern Loads.
Maximum hanger forces: 980.938 Ib (Left) and 980.938 Ib (Right).
Program Version 8.2 - 1211712004
I ( ,..
,---
06 beam at Living/Gallery-Roof Beam
4 Seasons Engineering Inc.
Project: DELGUZZI DR
Job: PEABODY
Client: PEABODY
Page 1
10:29: 16 05/04/07
Designed by: Donna Petersen P.E.
Checked by:
Input Data
!Q'Wt
Left Cantilever: None
Check for repetitive use? Yes
Dead Load: 17 psf
Allow. LL Deflection: U240
Eb: 1800000 psi
Main Span: 10'6"
Tributary Width: 16'6"
Live Load: 0 psf
Allow. TL Deflection: U180
fv: 240 psi
~"'~m~'Ifh~tI'_}"""I-="'**'~"l"M'_'"
~1"i1="Wl,~! '" ..'6'"" ,fuiHTii'"lruwiil'*w"'iN@'""'**l'$*
R:i...~lhJfl1$>~':: .es~_~n' , ~- '~,{il~,:: y~, '-.~JI~t5~~1w
Right Cantilever: None
Slope: 0:12
Snow Load: 25 psf
DOL: 1.150
Fb: 2400 psi
User Defined Loads
Dead
Uniform
0'
20'
100
Design Checks
Max. Value
Allowable
% of Allow.
Location
4163.25
4205.51
99 tI
0'
2283.84
2760
83 tI
5'3"
160.908
276
58 tI
9'7-1/2"
-0.2079
0.525
39 tI
5'3"
-0.3997
0.7
57 tI
5'3"
Reactions and Bearing
0'
10'6"
2.07
2.07
4163.25
4163.25
Self-weight of member is not included.
Member has an actuaVallowable ratio in span 1 of 83 tI %.
Design is governed by bending fb/Fb.
Governing load combination is Dead+Snow Condition 1 w/Pattern Loads.
Maximum hanger forces: 4163.251b (Left) and 4163.25 Ib (Right).
Program Version 8.2 - 1211712004
\~
.. -
BOISEN
.. BC CALC@ 9.3 Design Report - US
Build 057
Job Name: Peabody
Address: Delguzzi Drive
City, State, Zip: Port Angeles, WA 98362
Customer:
Code reports: ESR-1336
Single 9-1/2" Bel@ 5000-1.7 OF
3 spans I No cantilevers I 0/12 slope
16" OCS I Non-Repetitive I Glued & nailed construction
File Name: BC CALC Project
Description: J01
Specifier:
Designer: DONNA J PETERSEN PE
Company: 4 SEASONS ENGINEERING INC
Misc:
Joist\J01
Monday, May 07,200710:56
BO, 4-3/8"
LL 272 Ibs
DL 102 Ibs
B1,3-1/2"
LL 698 Ibs
DL 277 Ibs
B2, 3-1/2"
LL 673 Ibs
DL 262 Ibs
B3, 4-3/8"
LL 259 Ibs
DL 95 Ibs
Total Horizontal Product Length = 32-06-00
Live Dead Snow Wind Roof Live
Load T e Ref. Start 'End 100% 90% 115% 133% 125% DCS
Unto Area (pst) Left 00-00-00 32-06-00 40 17 16"
Controls Summa Value % Allowable Duration Load Case S an Location Disclosure
Pos. Moment 811 ft-Ibs 33.0% 100% 14 1 - Internal Completeness and accuracy of input must
Neg. Moment -1018 ft-Ibs 41.4% 100% 18 1 - Right be verified by anyone who would rely on
End Reaction 3461bs 30.8% 100% 14 1 - Left output as evidence of suitability for
Int. Reaction 9531bs 45.4% 100% 18 1 - Right particular application. Output here based
Cont. Shear 491 Ibs 33.3% 100% 18 1 - Right on building code-accepted design
properties and analysis methods.
Total Load Defl. U1432 (0.09") 25.1% 14 1 Installation of BOISE engineered wood
Live Load Defl. U1844 (0.07") 52.1% 14 1 products must be in accordance with
Total Neg. Defl. -0.031" 6.3% 14 2 current Installation Guide and applicable
Max Defl. 0.09" 9.0% 14 1 building codes. To obtain Installation Guide
Span 1 Depth 14.2 n/a 2 or ask questions, please call
(800)232-0788 before installation.
% Allow % Allow BC CALC@, BC FRAMER@, AJSTM,
Value Su ort Member Material ALLJOIST@, BC RIM BOARDTM, BCI@,
3741bs 10.6% n/a Hem-Fir BOISE GLULAMTM, SIMPLE FRAMING
9751bs 22.3% n/a Douglas Fir SYSTEM@, VERSA-LAM@, VERSA-RIM
PLUS@, VERSA-RIM@,
9361bs 21.4% n/a Douglas Fir VERSA-STRAND<ID, VERSA-STUD<ID are
3531bs n/a n/a Unspecified trademarks of Boise Wood Products,
L.L.C.
Notes
Design meets User specified (U360) Total load deflection criteria.
Design meets User specified (U960) Live load deflection criteria.
Design meets arbitrary (1") Maximum load deflection criteria.
Composite EI value based on 23/32" thick sheathing glued and nailed to joist.
Page 1 of 1
\A
Basics of Brick Veneer Construction &
Workmanship Checklist
By design, brick veneer walls are a
drainage-type wall system. Water is
assumed to penetrate the brickwork;
therefore, precautions must be taken to
both minimize its entry and to redirect
any water that does get in back OUt to
the exterior. Proper flashing, weeps,
and an air space are all necessary to
create an efficient drainage system.
To verifY that all components are in
place, some job site inspection should
occur. Correcting a drainage system
after it is already completed can
become very expensive. Accordingly,
the Brick Industry Association has
produced a Brick Veneer Construction
Checklist (see checklist on next page)
to assist with the installation of rhese
key items.
Support of Brick Veneer
Brick veneer must be placed on a
level suPPOrt of adequate depth. The
mortar joint on the brick ledge or slab
will accommodate some variations in
level, but the mortar joint should not
be more than 3/4-inch thick. Model
codes require that 2/3 of the brick
thickness bears on the supporting
foundation or lintel.
Air Space
Model codes further require a nominal
I-inch air space to drain water and to
keep brick and mortar from making
direct contact with the sheathing.
Some mortar in the air space is to be
expected due to the process oflaying
brick; however, the air space should
not be clogged to the extent that it
inhibits drainage.
Through-Wall Flashing
Foundations and lintels alone cannot
redirect the water in a consistent
manner; therefore, flashing must be
installed to channel moisture out, and
in doing so, to protect the interior
(see Figure 1). Model building codes
require Hashing at the foundation.
above window and door heads. at
window sills. and where the roof of
a one-story wing meets a two-story
brick veneer wall, even at areas where
a wall comes up against a lower roof.
Flashing should be installed wherever
the air space is closed off.
The Hashing should extend from the
outside face of the veneer, through the
thickness of the brick veneer. across
the air space to the backing, and
then up behind the water-resistant
barrier or attached over the water-
resistant barrier wi th a termination
bar. Where more than one piece of
flashing is required. flashing pieces
should be overlapped and sealed with
a compatible mastic.
Weeps should be placed directly above
the Hashing to help water drain from
the wall. These weeps are often open
head joints. but they can be vents as
well. Space weeps approximately every
third brick. or 24 inches o.c. Poking a
screwdriver into the wet mortar during
construcrion or drilling afterwards is
not a proper way to create a weep.
Water-Resistant Barriers
and Air Barriers
Model building codes generally
require a water-resistant barrier on
-------.------.---.--...-....-...-----.---
FIGURE 1
. Water-Resistant Barrier
ThroughWall. Flashing
W,i.tetResistant.
. Barrier .
Workmansl1lp C~~ckllstltems
the sheathing. Typically, one can
use #15 felt. although other water-
resisrant materials-such as Tyvek.
some types of insulation. and other
sheathing products that are approved
by inspectors and conform to the code
-are allowed. Water-resistant barriers
will perform adequately only when
joints. seams, and punctures are sealed
properly with durable materials.
Wall Ties
Wall ties, somerimes referred to as
anchors. fasten the brick veneer to the
backing. Each wall tie should suPPOrt
no more than 2.67 square feet of
brickwork. In addition. ties should be
spaced no more than 24 inches o.c.
horizontally and vertically. Since most
studs are spaced at 16 inches o.c.,
the maximum vertical distance for tie
placement is 24 inches o.c. On one
I