HomeMy WebLinkAbout1329 Rook Dr - BuildingPREPARED 1/21/09 10 59 47 INSPECTION TICKET PAGE 2
CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 1/21/09
ADDRESS 1329 ROOK DR
TENANT NBR GREEN CROW PRO
CONTRACTOR ACCENT CONST OF SEQUIM INC
OWNER GREEN CROW TIMBER LLC
PARCEL 06 30 14 5 3 0678 0000
APPL NUMBER 07 00000530 RES NEW SFR
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
SUBDIV
PHONE (360) 683 3307
PHONE
BL99 01 1/20/09 JLL BLDG FINAL
1/20/09 DA January 20 2009 3 42 43 PM 1pangrle
TODD 461 9566
BLDG FINAL
January 20 2009 4 20 24 PM jlierly
verify electrical final /positive slope away from
foundation /address numbers on front of structure/j11
BL99 02 1/21/09 BLDG FINAL
`l January 21 2009 10 57 50 AM 1pangrle
1P4eL TODD 461 9566
BLDG FINAL
COMMENTS AND NOTES
PREPARED 1/20/09 15 46 19
CITY OF PORT ANGELES
ADDRESS 1329 ROOK DR
TENANT NBR GREEN CROW PRO
CONTRACTOR ACCENT CONST OF SEQUIM INC
OWNER GREEN CROW TIMBER LLC
PARCEL 06 30 14 5 3 0678 0000
APPL NUMBER 07 00000530 RES NEW SFR
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
PERMIT ME 00 MECHANICAL PERMIT
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
ME99 01 1/20/09 iI
PERMIT PL 00 PLUMBING PERMIT
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
INSPECTION TICKET
INSPECTOR JAMES LIERLY
SUBDIV
PHONE (360) 683 3307
PHONE
BL99 01 1/20/09 T BLDG rINAL
-11-t January 20 2009 3 42 43 PM 1pangrle
TODD 461 9566
BLDG FINAL
MECHANICAL FINAL
January 20 2009 3 43 33 PM 1pangrle
TODD 461 9566
MECHANICAL FINAL
PL2 01 9/26/07 JLL PLUMBING ROUGH IN
9/27/07 AP 09/25/2007 02 11 PM LPANGRLE
JOHN 460 6902
ROUGH IN PLUMBING
09/27/2007 12 23 PM JLIERLY
PL99 01 1/20/09 LL PLUMBING 0INAL
January 20 2009 3 43 56 PM 1pangrle
TODD 461 9566
PLUMBING FINAL
COMMENTS AND NOTES
PAGE 2
DATE 1/20/09
*2E5Egtr._.
f c7S( v
ft Poo
PREPARED 11/21/07 9 17 42 INSPECTION TICKET PAGE 8
CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 11/21/07
ADDRESS 1329 ROOK DR SUBDIV
TENANT NBR GREEN CROW PRO
CONTRACTOR ACCENT CONST OF SEQUIM INC PHONE (360) 683 3307
OWNER GREEN CROW TIMBER LLC PHONE
PARCEL 06 30 14 5 3 0678 0000
APPL NUMBER 07 00000530 RES NEW SFR
PERMIT BPR 00 BUILDING PERMIT RESIDENTIAL
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
BL1 01 8/09/07 JLL BLDG FOUNDATION FOOTING
8/09/07 AP 08/09/2007 08 18 AM LPANGRLE
TODD 461 9566
FOOTING
08/09/2007 04 30 PM JLIERLY
BLFW 01 8/16/07 PB BLDG FOUND FTG /STEM WALL
8/16/07 AP 08/16/2007 08 19 AM LPANGRLE
TODD 461 9566
FOUNDATION STEMWALLS
08/16/2007 04 30 PM PBARTHOL
BLED 01 8/24/07 JLL BLDG FOUNDATION DRAINAGE
8/24/07 AP 08/24/2007 08 25 AM LPANGRLE
TODD 461 9566 OR 9564
FOUNDATION DRAINAGE
08/24/2007 04 36 PM JLIERLY
BLHD 01 9/27/07 JLL BLDG FRAMING HOLD DOWNS
9/27/07 DA 09/27/2007 08 20 AM LPANGRLE
CHUCK 461 2717
HOLD DOWNS
09/27/2007 04 46 PM JLIERLY
BL9 01 9/27/07 JLL BLDG SHEARWALL
9/27/07 AP 09/27/2007 08 19 AM LPANGRLE
CHUCK 461 2717
SHEARWALL
09/27/2007 04 46 PM JLIERLY
BAIR 01 10/24/07 PB BLDG AIR SEAL
10/24/07 CA October 24 2007 8 37 00 AM 1pangrle
TODD 461 9566
AIRSEAL
BL3 01 10/24/07 PB BLDG FRAMING
10/24/07 CA October 24 2007 8 37 35 AM 1pangrle
TODD 461 9566
FRAMING
BAIR 02 10/29/07 PB BLDG AIR SEAL
10/29/07 AP October 29 2007 10 02 34 AM 1pangrle
TODD 461 9566
AIRSEAL
BL3 02 10/29/07 PB BLDG FRAMING
10/29/07 AP October 29 2007 10 02 03 AM 1pangrle
TODD 461 9566
FRAMING
BLI 01 11/05/07 JLL BLDG INSULATION
11/05/07 AP November 5 2007 8 11 27 AM 1pangrle
TODD 461 9566
INSULATION
November 5 2007 4 14 36 PM jlierly
BLDR 01 11/21/07 JL BLDG DRYWALL IBWP
_j,,,;�1 November 20 2007 3 46 38 PM 1pangrle
TODD 461 9566
INTERIOR DRYWALL NAILING
COMMENTS AND NOTES
PREPARED 11/05/07 12 02 39 INSPECTION TICKET PAGE 7
CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 11/05/07
ADDRESS 1329 ROOK DR SUBDIV
TENANT NBR GREEN CROW PRO
CONTRACTOR ACCENT CONST OF SEQUIM INC PHONE (360) 683 3307
OWNER GREEN CROW TIMBER LLC PHONE
PARCEL 06 30 14 5 3 0678 0000
APPL NUMBER 07 00000530 RES NEW SFR
PERMIT BPR 00 BUILDING PERMIT RESIDENTIAL
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
BL1 01 8/09/07 JLL BLDG FOUNDATION FOOTING
8/09/07 AP 08/09/2007 08 18 AM LPANGRLE
TODD 461 9566
FOOTING
08/09/2007 04 30 PM JLIERLY
BLFW 01 8/16/07 PB BLDG FOUND FTG /STEM WALL
8/16/07 AP 08/16/2007 08 19 AM LPANGRLE
TODD 461 9566
FOUNDATION STEMWALLS
08/16/2007 04 30 PM PBARTHOL
BLFD 01 8/24/07 JLL BLDG FOUNDATION DRAINAGE
8/24/07 AP 08/24/2007 08 25 AM LPANGRLE
TODD 461 9566 OR 9564
FOUNDATION DRAINAGE
08/24/2007 04 36 PM JLIERLY
BLHD 01 9/27/07 JLL BLDG FRAMING HOLD DOWNS
9/27/07 DA 09/27/2007 08 20 AM LPANGRLE
CHUCK 461 2717
HOLD DOWNS
09/27/2007 04 46 PM JLIERLY
BL9 01 9/27/07 JLL BLDG SHEARWALL
9/27/07 AP 09/27/2007 08 19 AM LPANGRLE
CHUCK 461 2717
SHEARWALL
09/27/2007 04 46 PM JLIERLY
BAIR 01 10/24/07 PB BLDG AIR SEAL
10/24/07 CA October 24 2007 8 37 00 AM 1pangrle
TODD 461 9566
AIRSEAL
BL3 01 10/24/07 PB BLDG FRAMING
10/24/07 CA October 24 2007 8 37 35 AM 1pangrle
TODD 461 9566
FRAMING
BAIR 02 10/29/07 PB BLDG AIR SEAL
10/29/07 AP October 29 2007 10 02 34 AM 1pangrle
TODD 461 9566
AIRSEAL
BL3 02 10/29/07 PB BLDG FRAMING
10/29/07 AP October 29 2007 10 02 03 AM 1pangrle
TODD 461 9566
FRAMING
BLI 01 11/05/07 J L BLDG INSULATION
November 5 2007 8 11 27 AM 1pangrle
TODD 461 9566
V INSULATION
COMMENTS AND NOTES
PREPARED 10/29/07 10 05 02 INSPECTION TICKET PAGE 1
CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 10/29/07
ADDRESS 1329 ROOK DR SUBDIV
TENANT NBR GREEN CROW PRO
CONTRACTOR ACCENT CONST OF SEQUIM INC PHONE (360) 683 3307
OWNER GREEN CROW TIMBER LLC PHONE
PARCEL 06 30 14 5 3 0678 0000
APPL NUMBER 07 00000530 RES NEW SFR
PERMIT BPR 00 BUILDING PERMIT RESIDENTIAL
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
BL1 01 8/09/07 JLL BLDG FOUNDATION FOOTING
8/09/07 AP 08/09/2007 08 18 AM LPANGRLE
TODD 461 9566
FOOTING
08/09/2007 04 30 PM JLIERLY
BLFW 01 8/16/07 PB BLDG FOUND FTG /STEM WALL
8/16/07 AP 08/16/2007 08 19 AM LPANGRLE
TODD 461 9566
FOUNDATION STEMWALLS
08/16/2007 04 30 PM PBARTHOL
BLFD 01 8/24/07 JLL BLDG FOUNDATION DRAINAGE
8/24/07 AP 08/24/2007 08 25 AM LPANGRLE
TODD 461 9566 OR 9564
FOUNDATION DRAINAGE
08/24/2007 04 36 PM JLIERLY
BLHD 01 9/27/07 JLL BLDG FRAMING HOLD DOWNS
9/27/07 DA 09/27/2007 08 20 AM LPANGRLE
CHUCK 461 2717
HOLD DOWNS
09/27/2007 04 46 PM JLIERLY
BL9 01 9/27/07 JLL BLDG SHEARWALL
9/27/07 AP 09/27/2007 08 19 AM LPANGRLE
CHUCK 461 2717
SHEARWALL
09/27/2007 04 46 PM JLIERLY
BAIR 01 10/24/07 PB BLDG AIR SEAL
10/24/07 CA October 24 2007 8 37 00 AM 1pangrle
TODD 461 9566
AIRSEAL
BL3 01 10/24/07 PB BLDG FRAMING
10/24/07 CA October 24 2007 8 37 35 AM 1pangrle
TODD 461 9566
FRAMING
BAIR 02 10/P JLL BLDG eIR SEAL
,n
October 29 2007 10 02 34 AM 1pangrle
TODD 461 9566
AIRSEAL
BL3 02 10/29/07 J L BLDG FRAMING
October 29 2007 10 02 03 AM 1pangrle
TODD 461 9566
FRAMING
COMMENTS AND NOTES
i (10/29/2007) Sue Roberds RE. 1329 Rook Drive Page 1
From
To
Date.
Subject:
Sue,
I just spoke with Steve Zenovic and it appears that all sedimentation
control measures around the house at 1329 Rook Drive have been addressed We
would appreciate an inspection and removal of the red tag as soon as
possible. If there are any problems or concerns with the work please let me
know as soon as possible.
Thank you
Tim
Original Message
From Sue Roberds [mailto:Sroberds @cityofpa.us]
Sent: Wednesday October 24 2007 12:38 PM
To tim @greencrow corn
Cc: Amanda Roberts
Subject: 1329 Rook Drive
Dear Tim
A morning inspection of Rook Drive by Glenn Cutler and Roger Vess identified
that stormwater measures around the perimeter of 1329 Rook Drive are not up
to standard Silt fencing is not functioning and drainage is awry The
remainder of the subdivision appeared to be fine. A building inspection
request for air seal and frame will not be done until the stormwater
measures are corrected I had hoped to let you know that the site would be
posted to stop work before it occurred, but it has, and so wanted to let you
know the reason at this point. As soon as the stormwater issues have been
corrected, normal inspections will continue and you can continue with
construction.
Will see you this evening.
Sue
'Tim Woolett' <tim @greencrow corn>
'Sue Roberds <Sroberds @cityofpa.us>
-11
RE. 1329 Rook Drive
1,06/216/2007) Sue"Roberds 1329 Rook Drive Pagel
From 'Steve Zenovic' <steve @zenovic net>
To 'Sue Roberds' <Sroberds @cityofpa.us>
Date 10/25/211117-9.30 AM
Subject: 1329 Rook Drive
Attachments: 1329 ROOK DRIVE pdf
CC
Sue-
'Glenn Cutler' <GCUTLER @cityofpa us> 'Tim Woolett' <tim @greencrow corn>
I met with Chris Donnell on site at 1329 Rook Drive this morning to go over
the storm water pollution prevention control system for the house under
construction Attached is a sketch ?showing the measures that need to be
completed These include
Repair /reinstall /replace siltation fence to west and south of house; the
building contractor was undertaking this work while we were on site
Install rock check dams or straw wattles in the two diversion ditches that
lead into the existing siltation pond to the south of the site
Install quarry spall pad at the outlet of the pipe under Rook Drive that
leads into the siltation pond per the SWPPP for the project
I will notify you when this work is complete and ready for inspection Let
me know if you have any questions
Thanks,
Steve
STOP WORK NOTICE
Effective Date &4
Location of Work 3,asE?
Name of Permit Holder
Address of Permit Hol
Building Official
G TY OF POR ANGELES
DEPARTMENT OF
COMMUNITY DEVELOPMENT
Budding Division
aoo T Time 3Do
oc k 2
.1( X 34
Posted By
2
B ar .d
'.1
Call 417 -4815 for
further information
Permit No eC7 3
Permission to continue construction, alteration, maintenance or
repair work of any kind is hereby revoked or does not exist until B
conditions set, forth in the ordinances and building codes of the \f)
City of Port Angeles are complied with
r
WARNING. CONTINUATION. OF WORK OR REMOVAL, OF THIS
.NOTICE IS A MISDEMEANOR AND IS PUNISHABLE BY STATE.
LAW
NOTICE.. TO BE REMOVED ONLY BY BUILDING SECTION:
PERSONNEL
J
tY
PREPARED 10/24/07 9 42 21 INSPECTION TICKET PAGE 8
CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 10/24/07
ADDRESS 1329 ROOK DR SUBDIV
TENANT NBR GREEN CROW PRO
CONTRACTOR ACCENT CONST OF SEQUIM INC PHONE (360) 683 3307
OWNER GREEN CROW TIMBER LLC PHONE
PARCEL 06 30 14 5 3 0678 0000
APPL NUMBER 07 00000530 RES NEW SFR
PERMIT BPR 00 BUILDING PERMIT RESIDENTIAL
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
BL1 01 8/09/07 JLL BLDG FOUNDATION FOOTING
8/09/07 AP 08/09/2007 08 18 AM LPANGRLE
TODD 461 9566
FOOTING
08/09/2007 04 30 PM JLIERLY
BLFW 01 8/16/07 PB BLDG FOUND FTG /STEM WALL
8/16/07 AP 08/16/2007 08 19 AM LPANGRLE
TODD 461 9566
FOUNDATION STEMWALLS
08/16/2007 04 30 PM PBARTHOL
BLFD 01 8/24/07 JLL BLDG FOUNDATION DRAINAGE
8/24/07 AP 08/24/2007 08 25 AM LPANGRLE
TODD 461 9566 OR 9564
FOUNDATION DRAINAGE
08/24/2007 04 36 PM JLIERLY
BLHD 01 9/27/07 JLL BLDG FRAMING HOLD DOWNS
9/27/07 DA 09/27/2007 08 20 AM LPANGRLE
CHUCK 461 2717
HOLD DOWNS
09/27/2007 04 46 PM JLIERLY
BL9 01 9/27/07 JLL BLDG SHEARWALL
9/27/07 AP 09/27/2007 08 19 AM LPANGRLE
CHUCK 461 2717
SHEARWALL
09/27/2007 04 46 PM JLIERLY
BAIR 01 10/24/07 JLL BLDG AIR SEAL
October 24 2007 8 37 00 AM 1pangrle
TODD 461 9566
AIRSEAL
BLDG FRAMING
October 24 2007 8 37 35 AM 1pangrle
TODD 461 9566
FRAMING
BL3 01 10// 244/07 JLL
1
COMMENTS AND NOTES
PREPARED 9/27/07 12 24 27 INSPECTION TICKET PAGE 10
CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 9/27/07
ADDRESS 1329 ROOK DR SUBDIV
TENANT NBR GREEN CROW PRO
CONTRACTOR ACCENT CONST OF SEQUIM INC PHONE (360) 683 3307
OWNER GREEN CROW TIMBER LLC PHONE
PARCEL 06 30 14 5 3 0678 0000
APPL NUMBER 07 00000530 RES NEW SFR
PERMIT BPR 00 BUILDING PERMIT RESIDENTIAL
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
BL1 01 8/09/07 JLL BLDG FOUNDATION FOOTING
8/09/07 AP 08/09/2007 08 18 AM LPANGRLE
TODD 461 9566
FOOTING
08/09/2007 04 30 PM JLIERLY
BLFW 01 8/16/07 PB BLDG FOUND FTG /STEM WALL
8/16/07 AP 08/16/2007 08 19 AM LPANGRLE
TODD 461 9566
FOUNDATION STEMWALLS
08/16/2007 04 30 PM PBARTHOL
BLDG FOUNDATION DRAINAGE
08/24/2007 08 25 AM LPANGRLE
TODD 461 9566 OR 9564
FOUNDATION DRAINAGE
08/24/2007 04 36 PM JLIERLY
BLHD 01 9/27/07 BLDG FRAMING HOLD DOWNS
09/27/2007 08 20 AM LPANGRLE
CHUCK 461 2717
HOLD DOWNS
BL9 01 9/27/07 JL BLDG SHEARWALL
09/27/2007 08 19 AM LPANGRLE
CHUCK 461 2717
SHEARWALL
BLFD 01 8/24/07 JLL
8/24/07 AP
COMMENTS AND NOTES
PREPARED 9/26/07 11 07 10 INSPECTION TICKET PAGE 9
CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 9/26/07
ADDRESS 1329 ROOK DR SUBDIV
TENANT NBR GREEN CROW PRO
CONTRACTOR ACCENT CONST OF SEQUIM INC PHONE (360) 683 3307
OWNER GREEN CROW TIMBER LLC PHONE
PARCEL 06 30 14 5 3 0678 0000
APPL NUMBER 07 00000530 RES NEW SFR
PERMIT PL 00 PLUMBING PERMIT
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
PL2 01 9/26/07
PLUMBING ROUGH IN
09/25/2007 02 11 PM LPANGRLE
JOHN 460 6902
ROUGH IN PLUMBING
COMMENTS AND NOTES
PREPARED 8/24/07 8 42 16 INSPECTION TICKET PAGE 5
CITY OF PORT ANGELES
INSPECTOR JAMES LIERLY
ADDRESS 1329 ROOK DR SUBDIV
TENANT NBR GREEN CROW PRO
CONTRACTOR ACCENT CONST OF SEQUIM INC PHONE (360) 683 3307
OWNER GREEN CROW TIMBER LLC PHONE
PARCEL 06 30 14 5 3 0678 0000
APPL NUMBER 07 00000530 RES NEW SFR
PERMIT BPR 00 BUILDING PERMIT RESIDENTIAL
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
BL1 01 8/09/07 JLL BLDG FOUNDATION FOOTING
8/09/07 AP 08/09/2007 08 18 AM LPANGRLE
TODD 461 9566
FOOTING
08/09/2007 04 30 PM JLIERLY
BLDG FOUND FTG /STEM WALL
08/16/2007 08 19 AM LPANGRLE
TODD 461 9566
FOUNDATION STEMWALLS
08/16/2007 04 30 PM PBARTHOL
BLED 01 8/24/07 /Jt,L/ BLDG FOUNDATION DRAINAGE
BLEW 01 8/16/07 PB
8/16/07 AP
08/24/2007 08 25 AM LPANGRLE
TODD 461 9566 OR 9564
FOUNDATION DRAINAGE
COMMENTS AND NOTES
DATE 8/24/07
PREPARED 8/16/07 10 18 50 INSPECTION TICKET PAGE 11
CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 8/16/07
ADDRESS 1329 ROOK DR SUBDIV
TENANT NBR GREEN CROW PRO
CONTRACTOR ACCENT CONST OF SEQUIM INC PHONE (360) 683 3307
OWNER GREEN CROW TIMBER LLC PHONE
PARCEL 06 30 14 5 3 0678 0000
APPL NUMBER 07 00000530 RES NEW SFR
PERMIT BPR 00 BUILDING PERMIT RESIDENTIAL
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
COMMENTS AND NOTES
BL1 01 8/09/07 JLL BLDG FOUNDATION FOOTING
8/09/07 AP 08/09/2007 08 18 AM LPANGRLE
TODD 461 9566
FOOTING
08/09/2007 04 30 PM JLIERLY
BLEW 01 81L6/07 ILL BLDG FOUND FTG /STEM WALL
08/16/2007 08 19 AM LPANGRLE
TODD TI 9566
FOUNDATION DAATION STEMWALLS
PREPARED 8/09/07 8 43 22 INSPECTION TICKET PAGE 15
CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 8/09/07
ADDRESS 1329 ROOK DR SUBDIV
TENANT NBR GREEN CROW PRO
CONTRACTOR ACCENT CONST OF SEQUIM INC PHONE (360) 683 3307
OWNER GREEN CROW TIMBER LLC PHONE
PARCEL 06 30 14 5 3 0678 0000
APPL NUMBER 07 00000530 RES NEW SFR
PERMIT BPR 00 BUILDING PERMIT RESIDENTIAL
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
BL1 01 8/09/07 JLL
BLDG FOUNDATION FOOTING
08/09/2007 08 18 AM LPANGRLE
TODD 461 9566
FOOTING
COMMENTS AND NOTES
Application Number
Application pin number
Property Address
ASSESSOR PARCEL NUMBER
Tenant nbr name
Application type description
Subdivision Name
Property Use
Property Zoning
Application valuation
Owner
GREEN CROW TIMBER LLC ACCENT CONST OF SEQUIM INC
PO BOX 2439 942 STRAIT VIEW DRIVE
PORT ANGELES WA 983620312 SEQUIM WA 98382
(360) 683 3307
Structure Information 000 000 1701 SF SFR 552 SF ATTACHED GARAGE
Other struct info TOTAL LOT COVERAGE 1 00
CONSTRUCTION TYPE V N
Qty Unit Charge Per
Permit
Additional desc
Permit pin number
Permit Fee
Issue Date
Expiration Date
Permit
Additional desc
Permit pin number
Permit Fee
Issue Date
Expiration Date
T•\Policies \I102.15R [1 /05]
RIGHT OF WAY
CITY OF PORT ANGELES
PUBLIC WORKS UTILITIES DIVISION
321 EAST 5TH STREET PORT ANGELES, WA 98362
07 00000530
861420
1329 ROOK DR
06 30 14 5 3 0678 0000
GREEN CROW PRO
RES NEW SFR
RS9 RESDNTL SINGLE FAMILY
141231
Contractor
NUMBER OF STORIES
LOT SIZE
PROPOSED LOT COVERAGE
TOTAL LOT COVERAGE
NUMBER OF UNITS
Permit PUBLIC WORKS RES WATER SERV
Additional desc 5/8 DROP IN METER
Permit pin number 108258
Permit Fee 200 00
Issue Date 8/08/07
Expiration Date 2/04/08
BASE FEE
Qty Unit Charge Per
1 00 50 0000 ECH RIGHT OF WAY PERMIT
SANITARY SEWER HOOK UP
Plan Check Fee
Valuation
Special Notes and Comments
Address numbers shall be plainly visible from the street
Address numbers shall be a minimum of six inches high and be.
Date 8 /08/07
1 00
710028 00
2253 00
2253 00
1 00
00
141231
Extension
200 00
108266
50 00 Plan Check Fee 00
8/08/07 Valuation 141231
2/04/08
Extension
50 00
108274
120 00 Plan Check Fee 00
8/08/07 Valuation 141231
2/04/08
Qty Unit Charge Per Extension
1 00 120 0000 EA SAN SEWER HOOKUP 120 00
Separate Permits are required forelectrical work, SEPA, Shoreline, ESA, utilities, private and public improvements. This permit becomes
null and void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned
fora period of 180 days after the work as commenced, or if required inspections have not been requested within 180 days from the last
inspection I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of
laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not
presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construction.
5 C),\ •—i■57: tt
Signature of Contractor or Authorized Agent Date Signature of Owner (if owner is builder) Date
PW UTILITIES (Engineering Division)
WATERLINE METER
SEWER CONNECTION
SANITARY
STORM
SITE DRAINAGE
SITE EROSION CONTROL
PARKING
SIDEWALK
CURB GUTTER
DRIVEWAY APPROACH
BACK -FLOW DEVICE
RESIDENTIAL
CONSTRUCTION R.W PW/
ENGINEERING 417 -4807
FIRE 417 -4653 I
PLANNING DEPT 417 -4750 I
BUILDING 417 -4815
T-\Pol icies\ 1102.15R [1/05]
PERMIT INSPECTION RECORD
CALL 417 -4807 FOR UTILITY INSPECTIONS. PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAWFUL TO COVER,
INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT IN A CONSPICUOUS LOCATION
KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE
INSPECTION TYPE DATE ACCEPTED COMMENTS
YES I NO
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE
DATE YES NO COMMERCIAL DATE ACCEPTED
YES I NO
I I
I I
I I
I I
CONSTRUCTION R.W
PW ENGINEERING
FIRE DEPT
I PLANNING DEPT
1 BUILDING
�Of PORT,�,t,O
a v
14 i1C W:
Application Number
Application pin number
Special Notes and Comments
of contrasting color from the background
07/24/2007 11 33 AM SROBERDS The building permit will
result in the construction of a sfr in the RS 9 on an
approx 16 acre site Setbacks must be 25 front and rear
The site location is adjacent to a wetland WP 04 01
requires that a permanent fence and educational signage be
erected delineating and identifying the wetland boundaries
A temporary silt fence has been installed along the site s
west boundary that must be replaced with permanent fencing
prior to final of the subject sfr
07/31/2007 12 57 PM SROBERDS
Electrical load calculations and elctrical permits are
required
Any modifications to the City s electrical facilities will
be at the customer s expense
Ditches 8 culverts will be installed to City Stanards
See Public Works Engineering for Standards
Sanitary sewer connection inspection is required by
Public Works prior to back fill of ditch 24 hour advance
notice is required
Construct driveway to City Standards No concrete with
exposed aggregate allowed in the City road right of way An
inspection by Public Works Engineering is required prior to
pouring concrete
Other Fees
Fee summary
T•\Policies\ 1102.15R 1/05)
CITY OF PORT ANGELES
PUBLIC WORKS UTILITIES DIVISION
321 EAST 5TH STREET PORT ANGELES, WA 98362
07 00000530
861420
Page 2
Date 8/08/07
SEWER SYSTEM DELV CHARGE 1000 00
STATE SURCHARGE 4 50
PW WATER SYSTEM USE FEE 1230 00
Charged Paid Credited. Due
Permit Fee Total 370 00 370 00 00 00
Plan Check Total 00 00 00 00
Other Fee Total 2234 50 2234 50 00 00
Grand Total 2604 50 2604 50 00 00
Separate Permits are required for electrical work, SEPA, Shoreline, ESA, utilities, private and public improvements. This permit becomes
null and void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned
for a period of 180 days after the work as commenced, or if required inspections have not been requested within 180 days from the last
inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of
laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not
presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construction.
Signature of Contractor or Authorized Agent Date Signature of Owner (if owner is builder) Date
CALL 417 -4807 FOR UTILITY INSPECTIONS. PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAWFUL TO COVER,
INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT IN A CONSPICUOUS LOCATION
KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE
INSPECTION TYPE DATE ACCEPTED COMMENTS
PW UTILITIES (Engineering Division)
WATERLINE METER
SEWER CONNECTION
SANITARY
STORM
SITE DRAINAGE
SITE EROSION CONTROL
PARKING
SIDEWALK
CURB GUTTER
DRIVEWAY APPROACH
BACK -FLOW DEVICE
T•\Policies \1102.15R [1 /05j
RESIDENTIAL
CONSTRUCTION R. W PW/
ENGINEERING 417 -4807
FIRE 417 -4653 I
PLANNING DEPT 417 -4750 I
BUILDING 417 -4815
PERMIT INSPECTION RECORD
YES I NO
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE
DATE YES NO COMMERCIAL DATE ACCEPTED
YES I NO
I I
I I
I I
I I
CONSTRUCTION R.W
PW ENGINEERING
FIRE DEPT
I PLANNING DEPT
BUILDING
Application Number
Application pin number
Property Address
ASSESSOR PARCEL NUMBER
Tenant nbr name
Application type description
Subdivision Name
Property Use
Property Zoning
Application valuation
Owner
GREEN CROW TIMBER LLC
PO BOX 2439
PORT ANGELES
Structure Information
Other struct info
Expiration Date 2/04/08
Qty Unit Charge Per
1 00
5 00
1 00
14 7000
7 2500
10 6500
Qty Unit Charge Per
CITY OF PORT ANGELES
DEPARTMENT OF COMMUNITY DEVELOPMENT BUILDING DIVISION
321 EAST 5TH STREET PORT ANGELES, WA 98362
ECH
ECH
ECH
07 00000530
861420
1329 ROOK DR
06 30
0678 0000
GREEN CROW PRO
RES NEW SFR
RS9 RESDNTL SINGLE FAMILY
141231
Contractor
ACCENT CONST OF SEQUIM INC
942 STRAIT VIEW DRIVE
WA 983620312 SEQUIM WA 98382
(360) 683 3307
000 000 1701 SF SFR 552 SF ATTACHED GARAGE
TOTAL LOT COVERAGE 1 00
CONSTRUCTION TYPE V N
NUMBER OF STORIES 1 00
LOT SIZE 710028 00
PROPOSED LOT COVERAGE 2253 00
TOTAL LOT COVERAGE 2253 00
NUMBER OF UNITS 1 00
Permit BUILDING PERMIT RESIDENTIAL
Additional desc 1701 SF SFR W /552 SF ATT GAR
Permit pin number 101683
Permit Fee 1255 45 Plan Check Fee 502 18
Issue Date 8/08/07 Valuation 141231
Expiration Date 2/04/08
Qty Unit Charge Per Extension
BASE FEE 1020 25
42 00 5 6000 THOU BL -100 001 500K (5 60 PER K) 235 20
Permit MECHANICAL PERMIT
Additional desc
Permit pin number 107839
Permit Fee 111 60 Plan Check Fee 00
Issue Date 8/08/07 Valuation 0
BASE FEE
ME INSTALL 100- FAU
ME VENT FAN
ME OTHER APPL N/R
Permit PLUMBING PERMIT
Additional desc
Permit pin number 107821
Permit Fee 149 00 Plan Check Fee 00
Issue Date 8/08/07 Valuation 0
Expiration Date 2/04/08
BASE FEE
T \Policies \1102 15 building permit inspection record05 wpd [1/4/2005]
Date 8/08/07
corree4- ?0,t -cel number s
6(030 4i 2 00 80
Extension
50 00
14 70
36 25
10 65
Extension
50 00
Separate Permits are required for electrical work, SEPA, Shoreline, ESA, utilities private and public improvements. This permit becomes
null and void if work or construction authorized is not commenced within 180 days if construction or work is suspended or abandoned
fora period of 180 days after the work as commenced or if required inspections have not been requested within 180 days from the last
inspection I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of
laws and ordinances governing this type of workwillbe complied with whether specified herein or not. The granting of a permit does not
presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construction.
N- tTh
Signature of Contractor or Authorized Agent Date Signature of Owner (if owner is builder)
Date
CALL 417-4815 FOR BUILDING INSPECTIONS. CALL 417 -4735 FOR ELECTRICAL INSPECTIONS
CALL 417 -4807 FOR PUBLIC WORKS UTILITIES
PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAWFUL FUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE
INSPECTED AND ACCEPTED POST PERMIT IN A CONSPICUOUS LOCATION
KEEP PERMIT CARD AND APPROVED PLANS AT .IOB SITE.
FOUNDATION:
FOOTINGS
SHEAR WALLS WALLS
FOUNDATION DRAINAGE DOWN SPOUTS
PIERS
POST HOLES (POLE BLDGS.)
PLUMBING
UNDERFLOOR /SLAB
ROUGH -IN
WATER LINE (METER TO BLDG)
GAS LINE
BACK FLOW WATER
AIR SEAL
WALLS
CEILING
FRAMING
JOISTS GIRDERS
SHEAR WALL /HOLD DOWNS
WALLS ROOF CEILING
DRYWALL (INTERIOR BRACED PANEL ONLY)
T -BAR
INSULATION
SLAB
WALL FLOOR CEILING
MECHANICAL
ROUGH -IN
HEAT PUMP /FURNACE /DUCTS
GAS LINE
WOOD STOVE PELLET CHIMNEY
MANUFACTURED HOMES
FOOTING SLAB
BLOCKING HOLD DOWNS
SKIRTING
PLANNING DEPT SEPARATE PERMIT /1's
PARKING /LIGHTING
LANDSCAPING
RESIDENTIAL
ELECTRICAL LIGHT DEPT
INSPECTION TYPE DATE
BUILDING PERMIT INSPECTION RECORD
YES
ACCEPTED COMMENTS
NO
FINAL
FINAL
SEPA.
ESA.
SHORELINE:
417 -4735 ELECTRICAL
LIGHT DEPT
CONSTRUCTION R.W PW/ CONSTRUCTION R.W
ENGINEERING 417 -4807 PW ENGINEERING
FIRE 417 -4653 I I I FIRE DEPT
PLANNING DEPT 417 -4750 I I I PLANNING DEPT
BUILDING 417 -4815 I I I I BUILDING
T \Policies \1 102 15 building permit inspection record05.wpd [1/4/20051
DATE ACCEPTED BY.
DATE ACCEPTED BY.
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY /USE
DATE YES NO COMMERCIAL DATE ACCEPTED
YES I NO
of PORT W
MGW
r
Page 2
07 00000530 Date 8/08/07
Application pin number 861420
Application Number
Qty Unit Charge Per Extension
10 00 7 0000 ECH PL- EA FIXTURE ON ONE TRAP 70 00
1 00 7 0000 ECH PL- EA INSTALL WATER PIPE 7 00
1 00 15 0000 ECH PL- EA BLDG SEWER 15 0.0
1 00 7 0000 ECH PL- EA WATER HEATER 7 00
Special Notes and Comments
Address numbers shall be plainly visible from the street
Address numbers shall be a minimum of six inches high and be
of contrasting color from the background
07/24/2007 11 33 AM SROBERDS The building permit will
result in the construction of a sfr in the RS 9 on an
approx 16 acre site Setbacks must be 25 front and rear
The site location is adjacent to a wetland WP 04 01
requires that a permanent fence and educational signage be
erected delineating and identifying the wetland boundaries
A temporary silt fence has been installed along the site s
west boundary that must be replaced with permanent fencing
prior to final of the subject sfr
07/31/2007 12 57 PM SROBERDS
Electrical load calculations and elctrical permits are
required
Any modifications to the City s electrical facilities will
be at the customer s expense
Ditches 8 culverts will be installed to City Stanards
See Public Works Engineering for Standards
Sanitary sewer connection inspection is required by
Public Works prior to back fill of ditch 24 hour advance
notice is required
Construct driveway to City Standards No concrete with
exposed aggregate allowed in the City road right of way An
inspection by Public Works Engineering is required prior to
pouring concrete
Other Fees
Fee summary
Permit Fee Total 1516 05 1516 05 00 00
Plan Check Total 502 18 502 18 00 00
Other Fee Total 2234 50 2234 50 00 00
Grand Total 4252 73 4252 73 00 00
Separate Permits are required for electrical work, SEPA, Shoreline, ESA, utilities, private and public improvements This permit becomes
null and void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned
for a period of 180 days after the work as commenced or if required inspections have not been requested within 180 days from the last
inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of
laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not
presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construction.
Signature of Contractor or Authorized Agent Date Signature of Owner (if owner is builder) Date
T \Policies \1102_15 building permit inspection record05 wpd (1/4/2005]
CITY OF PORT ANGELES
DEPARTMENT OF COMMUNITY DEVELOPMENT BUILDING DIVISION
321 EAST 5TH STREET PORT ANGELES, WA 98362
SEWER SYSTEM DELV CHARGE 1000 00
STATE SURCHARGE 4 50
PW WATER SYSTEM USE FEE 1230 00
Charged Paid Credited Due
FOUNDATION DRAINAGE)DOWN SPOUTS
PIERS
POST HOLES (POLE BLDGS.I
PLUMBING
UNDERFLOOR /SLAB
ROUGH -IN
WATER LINE (METER TO BLDG)
GAS LINE
BACK FLOW WATER
AIR SEAL
WALLS
CEILING
FRAMING
I JOISTS GIRDERS
(HEAR WALL OLD DOWNS
WALLS ROOF CEILING
DRYWALL (INTERIOR BRACED PANEL ONLY)
T -BAR
INSULATION
SLAB
WALL FLOOR CEILING
MECHANICAL
ROUGH -IN
HEAT PUMP FURNACE DUCTS
GAS LINE
WOOD STOVE PELLET CHIMNEY
FOUNDATION:
FOOTINGS
SHEAR WALLS WALLS
MANUFACTURED HOMES
FOOTING SLAB
BLOCKING HOLD DOWNS
SKIRTING
PLANNING DEPT SEPARATE PERMIT #'s
PARKING /LIGHTING
LANDSCAPING
RESIDENTIAL
ELECTRICAL LIGHT DEPT 417 -4735
BUILDING PERMIT INSPECTION RECORD
CALL 417-4815 FOR BUILDING INSPECTIONS. CALL 4I7 -4735 FOR ELECTRICAL INSPECTIONS
CALL 417-4807 FOR PUBLIC WORKS UTILITIES
PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. i T IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK EEFORE1
INSPECTED AND 9CCEPTED POST PERMIT IN 4 CONSPICUOUS LOCATION
KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE.
INSPECTION TYPE DATE ACCEPTED COMMENTS
8(glol i TLC.
I I
5 /ZLtJ 7 I TLL
9-7,G'07 I S LA-
10 —2,9-0 r LL-
I
iQ
C -27- 0`? Imo_
I t- 21-0
I t- 5 -0 ILL-
YES I NO
SEPA.
ESA.
SHORELINE:
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY /USE
DATE YES NO COMMERCIAL
Sieimw oJU Z116 (67 a�
FINAL 0.'0 I DATE Mt ACCEPTED BY.
FINAL —2V ,o DATE ACCEPTED BY.
ELECTRICAL
LIGHT DEPT
CONSTRUCTION R.W PW/ CONSTRUCTION R.W
ENGINEERING 417 -4807 PW /ENGINEERING
FIRE 417 -4653 I I FIRE DEPT
I PLANNING DEPT 417 -4750 I I PLANNING DEPT
I BUILDING 417 -4815 1 1,-09 I SLL_ I I BUILDING
Ti Policies \1102 15 building permit inspection record05.wpd [1/4/2005]
0
DATE I ACCEPTED I
I YES I NO I
VJ
I I I
I I I I
I I I I
L(07/31/2007) Scott Johns Building Permit for Campbell Avenue Property Page 1
From
To
Date
Subject:
Scott,
'Tim Woolett' <tim @greencrow com>
'Scott Johns' <Sjohns @cityofpa.us>
05/08/2007 1 05 PM
Building Permit for Campbell Avenue Property
As a follow up to our conversation this morning I looked in the codes and
the state regs and couldn't find anything relative to building on a lot that
has a pending land division approval. This doesn't surprise me in that a
preliminary approval is only binding on the subdivision of land that was
proposed A landowner need not carry out the proposal or such as our case
redesign it to an improved layout. There is nothing in the ordinance that
would preclude the construction of a home on a large tract of land provided
it meets setbacks can get utilities, and has access to an adjacent public
street. This proposal would meet setbacks, it already has utilities and it
is abutting Rook Drive Campbell Avenue and Wabash Street. We would access
from the northern terminus of Rook Drive while keeping access to Campbell
Avenue and Wabash Street closed
We acknowledge the risks involved with this proposal, which all fall on
Green Crow We recognize that misplacement of the residence could jeopardize
one of the lots in the event that it would result in insufficient setbacks.
We also recognize that a variance can not be granted as a form of relief for
any resultant setback violations. To offset this risk we will have Wengler
Surveying and Mapping mark the corners of the proposed lot to ensure an
accurate location and the setbacks will be those allowed under the existing
preliminary approval of the PRD As we discussed this first phase of the
PRD will remain largely unchanged except that there will be two fewer lots
under the latest proposal. Setbacks are not a problem because the placement
of the residence will be significantly back from any property line or public
going to market.
I hope this sheds some light on any questions as to weather or not this can
be done I appreciate your time Scott. Let me know if you have any questions
or feedback.
Tim
.f7
street. Remember the stretch of roadway beyond the paved end of Rook Drive
does not exist at this time so it will essentially be a driveway Our plan
is to have the first phase of the revised PRD finagled prior to the new home k
0
4
Eqt
K ra 7 1 Associates,
GEOTECHNICAL ENGINEERING E I RONMENTAL ENGINEERING
CONSTRUCTION TESTING AND INSPE N
DATE
PROJECT
PROJECT
LOCATION
KRAZAN PROJECT MANAGER.
1 A
A
P O Box 2439
Port Angeles, WA 98362
Superintendent /Representative:
1501 Field Report.do
.Y1
t'
f 1u
i l
...r
GREEN CROW
PROPERTIES, INC
Tim Woolett
JUL 3 0 2007 1 1 y5 vrt
I CITY OF PORT ANGELES
nUILDING DlvISION
Phone: (360) 417 3663
Fax. (360) 417 3674
Mobile: (360) 461 7149
email. tim @greencrow corn
nc
Technician:
CONTRACTOR.
JURISDICTION
PERMIT
INSPECTOR.
WEATHER. c 1 L.
C° m pa. 7 0—
d-ts
FIELD REPORT NO 94561
Serving the Western United States
W
t4 it
TEMP F'
Revision I
Effectiv Date 5/25/05
To the best of my knowledge, the above WAS NOT performed in accordance with the approved plans, specifications, and regulatory requirements.
DATE: /C
PROJECT
PROJECT I
LOCATION: t
KRAZAN PROJECT MANAGER:
n
5
/0
tom.
COMPACTION
AMP.M.. IMAM
azan Associates, Inc REPORT NO 13427
GEOTECHNICAL ENGINEERING ENVIRONMENTAL ENGINEERING
CONSTRUCTION TESTING AND INSPECTION
WASHINGTON DENSOMETER n SANDCONE
LOCATION MAP N
Test Elevation
J j 3
I
Map Location:
I] Attached
)j I
r r
215 West Dakota Ave. Clovis, CA 93612
2205 Coy Ave. Bakersfield, CA 93307
1025 Lane Palm Ave. #2E, Modesto, CA 95351
545 Parrott St. San Jose, GA 95112
5808 Price Ave. Bldg. 1016, McClellan, CA 95652
C. 4
9- e. r
Paved Areas (circle one) Sub Agg Asphalt
Building Pad (s)
Other
Trenches (circle one). Sewer Water/ Storm Drain Utly
Curve Test Method:
Daily Avg. Std
Count Densities
Daily Avg. Std
Count moisture 4
Gauge# �C f_2 i
To the best of my knowledge, the abov(WAS AS NOT
Superintendent /Representative:
CONTRACTOR:
PERMIT NO:
INSPECTOR:
JURISDICTION:
WEATHER: C Ir tf
Curve Unified Soils Classification
Location(Comments) Curve
l ei
(559) 348 -2200
(661) 837 -9200
(209) 572 -2200
(408) 271 2200
(916) 564 -2200
NUCLEAR TEST OTHER 7 r
Mode
Depth
Density Moist Percent
Compaction
--1,
r 7
L�
Max Dry
Density
I
V G
7
l 7
1
Revision 0
TEMP:
-a
Opt
Moisture
II
Required
This testing does not preclude the possibility that the soil or hot -mix asphalt may be loosened by future
construction activities or rainfall events. The compaction tests were performed at the approximate
locations and elevations shown and indicate relative compaction at those locations. Horizontal and
vertical limits of the compacted area were determined by others. Our firm does not guarantee earthwork
or paving construction, nor does our work relieve the contractor's responsibility to conform to the
approved project plans and specifications.
performed in accordance with the approved RI specifications, and regulatory requirements
Technician: LCZ-
4221 Brickell St. OntariO7f.A 9 a1
1501 15" St. NW Suite 106, Auburn, WA 98002
20714 State Hwy 305 NE Suite 3C, Poulsbo, WA 98370
19501 144 Ave. NE #F 300, Woodinville, WA 98072
(909) 974 -4400
(253) 939 -2500
(360) 598 -2126
(425) 485 -5519
2izzuri Associates, Inc
GEOTECHNICAL ENGINEERING ENVIRONMENTAL ENGINEERING
CONSTRUCTION TESTING AND INSPECTION
DATE: //3 /J
PROJECT 11(r v'
PROJECT
LOCATION:
KRAZAN PROJECT MANAGER:
WASHINGTON DENSOMETER n SANDCONE
LOCATION MAP N
Test Elevation
Map Location:
Attached
To the best of my knowledge, the
Superintendent /Representative:
215 West Dakota Ave. Clovis, CA 93612
2205 Coy Ave. Bakersfield, CA 93307
1025 Lone Palm Ave. #2E, Modesto, CA 95351
545 Parrott St. San Jose, CA 95112
5808 Price Ave. Bldg. 1016, McClellan, CA 95652
Location(Comments)
Curve
F ns7:
(559) 348 -2200
(661) 837 -9200
(209) 572 -2200
(408) 271 2200
(916) 564 -2200
Curve
CONTRACTOR:
PERMIT NO
INSPECTOR:
JURISDICTION:
WEATHER:
Unified Soils Classification
Mode
Depth
Curve Test Method: p r
Daily Avg. Std
Count Densities 4.e L1t Z
Daily Avg. Std
Count moisture
Gauge#
above WAS WAS NOT performed in accordance with the'approyed plans,
COMPACTION 1 3 j' 7 /1
REPORT NO 3 4 2 a-
NUCLEAR TEST n OTHER
n Paved Areas (circle one) Sub Agg Asphalt
--7.-- Building Pad (s)
Other
Trenches (circle one) Sewer Water Storm Drain Utly
Density Moist
Technician:
4221 Brickell St. Ontario, CA 91761
1501 15 St. NW Suite 106, Auburn, WA 98002
20714 State Hwy 305 NE Suite 3C, Poulsbo, WA 98370
19501 144th Ave. NE #F -300, Woodinville, WA 98072
Max Dry
Density
Percent
Compaction
Rev's' 0
TEMP:
Required
Opt
Moisture
This testing does not preclude the possibility that the soil or hot -mix asphalt may be loosened by future
construction activities or rainfall events. The compaction tests were performed at the approximate
locations and elevations shown and indicate relative compaction at those locations. Horizontal and
vertical limits of the compacted area were determined by others. Our firm does not guarantee earthwork
or paving construction, nor does our work relieve the contractor's responsibility to conform to the
approved project plans and specifications.
specifications, and regulatory requirements
(909) 974 -4400
(253) 939 -2500
(360) 598 -2126
(425) 485 -5519
w�
4.4
(7%4/2007)'Sue Roberd, RE. Fwd Wetland Fencing
From Tim Woolett' <tim @greencrow.com>
To 'Sue Roberds' Sroberds @cityofpa us>
Date 7/24/2007 9 AM
Subject: RE Fwd Wetland Fencing
Dear Sue
We have installed the silt fence as agreed and posted the signs as agreed
We object to your conditioning the building permit with the note you have
proposed however in that we need the permit to commence construction we
have no choice but to acquiesce, but do so under protest. It would be
greatly appreciated if you would release the building permit and the
temporary power permit. Please advise us of the amount due for wetland signs
and for any additional building permit fees so we can prepare payment.
Thank you
Tim
Original Message
From Sue Roberds [mailto Sroberds @cityofpa us]
Sent: Thursday July 19 2007 12:23 PM
To tim @greencrow com
Cc Mark Madsen Scott Johns
Subject: Re Fwd Wetland Fencing
Dear Tim
Scott forwarded your e-mail regarding the wetland fencing /building
permit to me for response I agree that our conversation regarding
fencing of the wetland (7/18/07) concluded with the understanding that a
temporary signed silt fence can be used to complete the east line of
the delineation from the point where the split rail fencing was placed
as of 7/18/07 You described the remaining run as approximately 130
feet north from that point and although I haven't verified the exact
run I assume you have measured and have determined that 130 feet would
complete the east line of the area per Wetland Permit 04 -01 This will
then define the entire west line of Lots 18 and 19 of the preliminary
PRD Three signs will also be spread along the silt fencing You took
the signs with you and are aware that Green Crow will pay for those
signs
Dennis request that the remaining north run of fencing be permitted to
be silt fencing is an acceptable compromise at this time as it will
protect the wetland from silt and debris entering the area as a result
of the development of Lots 18/19 to the east. However as noted during
our conversation the silt fencing is to be considered temporary A
permanent fence shall be placed prior to final of the residential
structure intended for Lots 18 and 19 of the PRD Although the north
and west boundaries of the wetland may be amended in the future the
east boundary will not change particularly since you are planning to
construct a residence on Lots 18/19 The building permit will contain a
note that permanent fencing per the Wetland Permit shall be installed
prior to final of the Lot 18/19 residence
0/24/2007) Sue Roberds RE. Fwd Wetland Fencing
I think this is an accurate accounting of our conversation The
building permit will be made ready for issuance once the fencing and
signage has been placed
Sue Roberds
Planning Manager
(7/19/2007) Sue Roberds Re Fwd Wetland Fencing
From Sue Roberds
To tim @greencrow corn
Subject: Re Fwd Wetland Fencing
Dear Tim
Scott forwarded your e-mail regarding the wetland fencing /building permit to me for response I agree that
our conversation regarding fencing of the wetland (7/18/07) concluded with the understanding that a
temporary signed silt fence can be used to complete the east line of the delineation from the point where
the split rail fencing was placed as of 7/18/07 You described the remaining run as approximately 130 feet
north from that point and, although I haven't verified the exact run I assume you have measured and have
determined that 130 feet would complete the east line of the area per Wetland Permit 04 -01 This will
then define the entire west fine of Lots 18 and 19 of the preliminary PRD Three signs will also be spread
along the silt fencing You took the signs with you and are aware that Green Crow will pay for those signs
Dennis request that the remaining north run of fencing be permitted to be silt fencing is an acceptable
compromise at this time as it will protect the wetland from silt and debris entering the area as a result of
the development of Lots 18/19 to the east. However as noted during our conversation, the silt fencing is
to be considered temporary A permanent fence shall be placed prior to final of the residential structure
intended for Lots 18 and 19 of the PRD Although the north and west boundaries of the wetland may be
amended in the future the east boundary will not change, particularly since you are planning to construct a
residence on Lots 18/19 The building permit will contain a note that permanent fencing per the Wetland
Permit shall be installed prior to final of the Lot 18/19 residence
I think this is an accurate accounting of our conversation The building permit will be made ready for
issuance once the fencing and signage has been placed
Sue Roberds
Planning Manager
CC Mark Madsen Scott Johns
(7/19/2007) Sue Roberds Fwd Wetland Fencing„ Pa9e a
From Scott Johns
To. Sue Roberds
Date: 7/17/2007 3 28 PM
Subject: Fwd Wetland Fencing
FYI
'Tim Woolett' <tim Tareencrow.com> 07/17/2007 3 05 PM
Scott,
As a follow up to our conversation earlier today, we understand that it is
agreed that we will place silt fence from the north end of the new cedar
split rail fence along the east side of the wetland buffer along the back
side of the retention pond to a point marking the south rear corner of the
proposed building site on the 'Campbell Avenue property' then northward
approximately 130 feet. Our contractor will do this tomorrow morning. Once
this measure is in place we understand that you will release the pending
building permit.
Tim
530
Page 1 I
The City of Port Angeles
Building inspections Dept.
Upon reviewing the single family residential plans submitted for permit, the
following are some of the items that will need to be taken in to consideration.
Foundation Footing The minimum size of a footing in Seismic zone D2 are as follows.
(1 Story 12" WI 6" min. thick (2 story 15" W/ 7" nun. thick) (3 story 23" W/ 8" min thick)
(Load bearing value of soil 1,500 (psf). With 2 4 bars horizontal continuous 3" off the
bottom of footing. The minimum specified compressive strength of concrete in basement
walls, foundation walls, exterior walls and other vertical concrete work exposed to weather
in moderate weathering table R402.2 of the IRC is 30001bs with a min. of 5% air entrained,
but not more that 7% Foundations in seismic categories D2 that exceed 50' -0 in either
direction are required to have a continuous footing per section R403.1.2 including support of
an interior braced wall line. Locating and marking the property boundary is required for a
footing inspection. Tables in chapter 4 of the IRC. Will be applied for soils that are heavy in
moisture (hydraulic) in nature or foundation wall over 5' -O" in height. Verify site conditions
and unbalanced back fill at time of application. Foundations Drains are required as per
section R 405.1 (see exception for soil classification)
2- Foundation walls. Vertical steel in foundation walls as of July 1 2004 Vertical bar reqd
to be', #4 bar with a hook and tied to the footing steel in place at 4' -0" 0 C. at footing
inspection. One #4 bar horizontal within the top 12 "of the wall.'/" anchor bolt with a 3" x
3" x' steel washer is required at 6' -0 "OC for a 1 story and 4' -0 "OC for a 2 story, along
and within 12" of each end the pressure treated sill plate. Crawl space ventilation is required
at (1') s.f. of vent per (150') s.f. of area per sec. R408.2. 2003 IRC. 6 mill black poly is
required in crawl space as a below grade moisture barrier per section R406.3.2 2003 MC.
Finish grade shall be a 6" slope away from foundation within 10' -0" of the foundation wall
measured horizontally as per sec. R406.3 2003 IRC.
3- Framing All connections from a pier to a post and beam are required to have positive
connection per code. In addition any connectors/ fasteners in contact with treaded wood are
req'd to be hot dipped zinc /galy (See manufacture details.) All floor joist are required to be
blocked with 2x material at the beam support. 7/16" OSB sheathing is required to be nailed
to pressure treated sill plate and bottom plate or sole plate of wall. (or other approved hold
down's). Attic ventilation is required at (1') s.f. of vent per (150') s.f. Of area with an
allowable 50% of ventilation can be located in the upper portion of the ridge if applicable
per 2003 IRC. Truss design and calculations are required upon submitting an application,
lateral connections are required to end walls where truss rafters are perpendicular to end
walls. A truss /rafter tie shall be required to prevent uplift per code.
4- Braced Wall Lines. In Seismic category D2 exterior and interior braced wall lines
cannot exceed 25' -0" Wall bracing must start within 8' -0" of a transverse wall or a designed
collector Standard wall bracing methods are required as per section R602.10.3 of the 2003
IRC. If the wall bracing methods cannot be met, then refer to "Alternate Braced wall panel"
Section 602.10.6 of the 2003 IRC. If any of the aforementioned methods cannot be met,
engineering design will be required for the "SHEAR WALL" design. Section R602.10.9 for
interior braced wall line support for 1 and 2 story buildings require a continuous footing
supporting a braced wall line, interior and exterior not to exceed 50' -0 "intervals.
FIi'
5- Egress. Rooms used for sleeping are required to have one window with 5.7'S.F of openable
space and a sill height of not more the 44" above finished floor for emergency escape per
2003 IRC.
6- Energy and Air Quality Insulation, Heating, Air conditioning, Lighting, Windows and
Appliances to meet 2003 WSEC VIAQ New single family structures are required to have
a whole house exhaust fan with a 24hr timer per table 3 -1, 3 -2, 3 -3 of the 2003 VIAQ
Mechanical fresh air intake (FAT) is required to have a 24 hr timer or windows in all
bedrooms and living, dining area may have intake ports for fresh air per 2003 VIAQ if zone
heat is applicable.
7- Dry Wall. (Gypsum wall board) 5/8" type "X" sheets rock is required in the accessible
usable space under stairs and on ceiling of a garage only if a habitable area is located above
the garage. The rating of the sheet rock nail pattern must be visible to the inspector Nail
pattern for all sheet rock 'A" and 5/8" to be 8" on center and 12" OC if drywall screws are
used. Per table 702.3.5 of the 2003 IRC. Interior braced wall panels are to be inspected prior
to tape, bed and texture. Moisture resistant wallboard is required around w /c. A cementuous
backer board is required for tiled areas at tub and showers. Vapor barrier is required. A
perm rated paint may be substituted for a poly vapor barrier on the warm in winter side.
8- Plumbing. Water heaters are required to have two approved seismic straps in the upper
and lower 1 /3` of the tank per UPC. T &P valve to be 3/4" I.D and directed to the exterior and
turned 90 degree downward not less that 6" 12" above finish grade. Water heater s are
required to have a 26 ga. Pan of other approved drain pan with a'/" drain line from pan to
exterior Impact protection for w/h and mechanical equip are required to resist 6,000lbs
impact if located in the garage area. All DWV are req'd. to be tested under water pressure
per 2003 UPC or air test (consult manufacture recommendations for air test) Min. test
pressure in Residential LPG is 30 lbs.
9- Smoke detectors. shall be located in each sleeping room and in the hall leading to each
sleeping area. One smoke detector is required at the top of each stairs, and at least one
smoke detector is required on every floor level. Smoke detectors must be within 6" to
12 "from the ceiling if mounted on wall. Smoke detector shall not be less than 36" from any
air return. Power supply for smoke detectors shall be from the main house supply that is not
switched and required to be battery back up. Smoke detectors to be inter connected so that
if one smoke detector alarm will start a chain reaction to all other smoke detectors as per
code.
10- Maximum building height allowable is 30' -0" based on an average grade plain per 2003
IRC. Property pins shall be located and marked for a footing inspection to verify zoning set
back requirements.
11 Safety glazed tempered glass required within 24" of any doorway edge, along with other
requirements as per 2003 IRC.
12- All water, sewer, gas, electrical, drywells, downspouts and footing drains are required to be
inspected before cover
This letter is not intended to cover all items required by the City of Port Angeles, but is to serve
as a guide to help you understand frequently asked questions, "ALL WORK IS SUBJECT TO
FIELD APPROVAL" 4/05.
g
BUILDING PERMIT APPLICATION
m Wool k
Fill out COMPLETELY and in INK. i our application and site plan MUST
1U If have arr 4 a il
COMPLETE to be accepted fur re 1, you unrc an; questions,
C�l' PERMITS (360) 417 -4815 FAK(360)417 -4711
yq ToAri St r es
Prccem-E- Co Y∎g+r -)6 t\
Applicant or Agent: r‹a�w ��.v o
Owner G r ee sr, l -lbw �Y b
Architect/Engineer
Contractor I- (ce CO 5 54 4 tateLicense #:kccEiv'S443OExp 3I7 t3 /O1
Address 94Z 3-rra l- V i e) CV City ?•\A P►'\qel
TYPE OF WORK.
lgt Residential F. New Constr Re roof
Multi- family 4ddition Move
Commercial Remodel Demolition
Repair Sign
BRIEF DESCRIPTION OF THE PROJECT
PLANNING USE ONLY
A Ad
COMMERCL4L/RESIDENTIAL. Occupancy Group•
f ve�
No of Stories. Lot Size. 1 /C :OZ'f3� Existing Sq Ft. C,
Total lot coverage (9ka3
ESA/Wetland(s) Yes No SEPA Checklist required? Yes No Other
T:\Policies\BL I102_13.wpd Applicant
4ahP r
Stove
p5 Garage
Deck
Other
New Z
Aior as20/ 1
FOR OFFICIAL USE' ONLY
Date Rec..1/ 7
01-
ate Approved
te Issued. <6 oi l
Phone 3(Qb 3L
Phone 5 c V 41 3 L54-
Address lice a Q,5 +L cit VGA- AY\ ei25 (Ji Zip 83 f
Phone 4
PROJECT ADDRESS_ u. ,A APX.11C ROOK Dr. ZONING
LEGAL DESCRIPTION Lot: Block. Subdivision.
CLALLAM COUNTY PARCEL NUMBER. (P 30 1 5 3d (P1
0
Phone.360 45-LRSe, f
Zip 9 (c?
'reel Surve Vo)t
A e e 0 5 +0 be. a. 5s 1` 5 r\ ed ;:a—‘- r`- LC,f
SIZE/V ALUATION
/7 0 I SF 7 Isp /„.9
53 SF 2_I 3 -g- /SF �l� 7‘
SF@$ /SF
TOTAL VALUATION 4 //Z30 8S
bed v c p w e-s cl es-+C c LAS/ a -1- 0-(7,G.. e_d
Occupant Load. Construction Type:
Proposed Sq Ft. 7 .2 TOTAL Sq Ft, Zz_S
APPROVALS
PLAN
BLDG
DPWU
FIRE
OTR> R
VALUATION OF CONSTRUCTION In all cases, a valuation amount must be entered by the applicant. This figure will be reviewed
and may be revised by the Building Division to comply with current fee schedules. Contact the Permit Coordinator at 417-4815 for assistance.
PLAN CHECK .IEEE IF a plan check fee. is due it must be submitted at the time the building .pe iit' application and construction plans are
submitted. All other permit fees are due at the time of permit issuance.
EXPIRATION OF PLAN REVIEW If no permit is issued within 180 days of the date of application, the application will expire. The
Building Official can extend the time for action by the applicant up to 180 days upon written request by the applicant (see Section R105.3.2
of the International Building/Residential Code, 2003). No application can be extended more than once.
1 hereby certify that 1 have read and examined this applicati d know the same to be true and correct. 1 am authorized to apply for this permit and
understand that it is my responsibility to de ne-wh �i re required ,not the City's, and fh Jim t obtain such permits prior to work.
Date. 5 7 0 7
1-0Cb- o,..1
v/
Cd,c3 o L3 060 8
i•
ro a 5€c& 5s3e
Lot 5 )S41
L
IL
PRD APPLICATION SITE PLAN
ANGELES, CLALLAM COUNTY, WASHINGTON
d
ROOK b 2 \1 A
SF�
0 SF
5230- SF
52 2 50- -SF.„ 4
5775�S,F� j 4785 SF, fl/ 4 I
TOTAL LOT ACREAGE
TOTAL OPEN SPACE
TOTAL PROPOSED RIGHT -OF -WAY
TOTAL OFF STREET PARKING
TOTAL ACREAGE
RECREATIONAL PARK OPEN SPACE
COMMUNITY OPEN SPACE
PASSIVE OPEN SPACE
TOTAL OPEN SPACE
6 68 ACRES
6 62 ACRES
3 12 ACRES
0._07 ACRES
16 49 ACRES
1 61 ACRES
1 92 ACRES
3 08 ACRES
41%
40%
19%
00%
100%
24*
29%
47*
6 61 ACRES 100%
PHASE I
PHASE II
PHASE III
PHASE IV
PHASE V
J
P SF P E
8-�4sres S
I /G I i i
11 4365 SF
c
I I
/11, I I /.I/
i �1
1 /I I i/I 11 6392 SF
/�U\ /If I .1
Ik 111 I �I1 1
LOTS 11 -20
LOTS 1 -10
LOTS 21 -35
LOTS 36 -42
MULTI FAMILY
�s \I r
II,
II.
J 1 mil'
6522 65]9 -F 7044 SF-_ 1( J.
1
-0-
-o-
-0-
RECEHE
AUG -7 2007
CAHai3, A0a:-wK
3
CITY OF PORT ANGELES
Dept. of Community Development C45:0-. Ci‘' 3 I 47 s 5 3v
1 7Q
L
h
co
13q RoK Dv
X47— 5 30
N. a
6vIctied 0 I -2I -1
Prescriptive Approach- Simple Form
For the NTTacl„ngt State Energy Code 2003 Edition
Climate Zone 1
Site Information Building Department Use Only
Lot:
Address. /Z !L e.- -.nL/(
v
City a rt AkI eu:<
State: 4)4 Zip: fg.31,2.
Contact: `?;..A GJcca /T
Phone: (//'7 3tC
Phone 2.
FAX.
Penult 0'7-- 5 30
Notes.
Table 6 -1
PRESCRIPTIVE REQUIREMENTS FOR GROUP R OCCUPANCY
CLIMATE ZONE 1
Unlimited Glazing Option Only
Option Glazing Glazing U- Factor Door Wall Wall Wall Slab
Area U- Vaulted Above Interior Exterior on
of Floor Vertical Overhead Factor Ceiling Ceiling Grade Below Below Floor Grade
Grade Grade
Unlimited
III Group R 3 0 40 0.58 0.20 R 38 R 30 R21 R 21 R 10 R -30 R 10
Occupancy
Only
This Project complies with the following:
The Project is a single family residence or duplex.
The Project is wood frame OR all of the insulation is interior or exterior of the framing.
/All building components meet the requirements listed in Table 6 -1 Option Ill.
The Project will meet all other provisions of the WSEC and VIAQ
The Project will take advantage of the following exceptions to the prescriptive option
602.6 Exception 1 One door, that is 24ft. Or less, that does not meet the standards allowed.
Location of the door taking tins exception
602.6 Exception 2. Doors with a U- Factor of 0 40 allowed without calculations, Option TIT only
Location of the Door (s) taking exception
Type of Heat Source: fill A
EXHIBIT A
1
L
I
L
L I
I 1
I
I
1
I Z
L. i
I
I 1
i I 1 I
I__I
1 I
1
t___
1 I
I I
I
1 _i_
I
I I
1
1
1
1_ t 1
1
1 1
I I
1 I I 1
i 11 1
1 1 I
1 I
-I 1 i 1 1
1
I I i i
I
i NI
t I I I 1
1 1
I I
j H 1 1 I
I 1 I I i 1 I
I__
1____
I 1
I
I-.
1 1 1 1
i i 1
lj
V
j
i
1
i i i li_S_ LL I J___ J____I ;J L 1
1 t 1
L I I i IL_ i___! 1 _I 1 ._.i.
t I
1
i 1 1
1
L
1
_I__ 1....
4 1
I
L 1 1 I
L
i i I I I I
1 i 1 -•-r-
1 1 1_ 1
1 1 -,--1---
L L
I I
1
i
1
t I I 1 1
I
i i r
I 1 i
o
FROM %r I1 ri Ia
To:
Larry Lauritzen
Lead GIRqn images
P_0- Box 979
Drsmopolis, WA 88537
Re: Dennis Yakovich project
New dwelling
City of Port Angeles
Question of need for drag strut
If I can be of further help. let me know_
FR:; NO, 3S0532706@ Feb, 04 2007 10' 05RM P1
MEMO
Ronald h'. Menu, P.E.
601 School Road
Aberdeen WA 8857?
060)02-M80
fax (360)532 -7060
rmeniat icarncast.net
R_H_ Maria, RE.
From= Ron Merle
Date: February 4, 2007
have reviewed your floor plan and braced wall plan for prescriptive path requirements. You
stated the building official is questioning need for drag strut connecting the girder truss above the
kitchen nook area. Since the girder truss is located in the building Interior, l sea no need for
design of drag strut provided the main building roof system is fully sheathed prior to garage roof
over-framing. This provides load transfer continuity the entire building length.
However l do see one item that should be considered for simplicity of the main roof truss system.
The side wall thirty-four fc tdiinension should extend to the outside walls on both the left and
right sides of the building_ That is, to the outside wail of the den on the left and the outside of the
wall at the walk -in closet on the right (the nine foot dimension [12 ft dim on the braced wall sheet]
should be moved to the inside wall of the garage).
ELECTRICAL PERMIT AND INSPECTION RECORD
CITY OF PORT ANGELES
360-417-4735
Application Number
Application pin number
Property Address
ASSESSOR PARCEL NUMBER:
Tenant nbr, name
Application type description
Subdivision Name
Property Use
Property Zoning . . .
Application valuation
07-00000530 Date 10/09/07
861420
1329 ROOK DR
06-30-14-5-3-0678-0000-
GREEN CROW PRO
RES NEW SFR
RS9 RESDNTL SINGLE FAMILY
141231
Owner
Contractor
GREEN CROW TIMBER LLC
PO BOX 2439
PORT ANGELES
ACCENT CONST. OF SEQUIM
942 STRAIT VIEW DRIVE
SEQUIM WA
(360) 683-3307
000 1701 SF SFR & 552 SF ATTACHED
TOTAL % LOT COVERAGE
CONSTRUCTION TYPE
NUMBER OF STORIES
LOT SIZE
PROPOSED LOT COVERAGE
TOTAL LOT COVERAGE
NUMBER OF UNITS
WA 983620312
Structure Information 000
Other struct info . .
permi t . . . . .
Additional desc .
Permit pin number
Sub Contractor
Permit Fee
Issue Date
Expiration Date
ELECTRICAL NEW RESIDENTIAL
HALVORSEN EL/ 2270 SFR
112078
HALVORSEN ELECTRIC
124.00
10/09/07
4/06/08
Plan Check Fee
Valuation
Qty
1. 00
2.00
1. 00
Unit Charge
69.0000
22.0000
11.0000
EL-R-SQFT FIRST 1300
EL-R-SQFT ADDITIONAL 500
EL-METERS REMOTE' INSTALL
Per
ECH
5C
ECH
Special Notes and Comments
Address numbers shall be plainly visible from the street.
Address numbers shall be a minimum of six inches high and be
of contrasting color from the background.
07/24/2007 11:33 AM SROBERDS --The building permit will
result in the construction of a sfr in the RS-9 on an
approx 16 acre site. Setbacks must be 25' front and rear.
The site location is adjacent to a wetland. WP 04-01
requires that a permanent fence and educational signage be
erected delineating and identifying the wetland boundaries.
A temporary silt fence has been installed along the site's
west boundary that must be replaced with permanent fencing
prior to final of the subject sfr.
07/31/2007 12:57 PM SROBERDS ---------------------------
Electrical load calculations and elctrical permits are
required.
Any modifications to the City's electrical facilities will
be at the customer's expense.
Ditches & 8" culverts will be installed to CityStanards.
See Public Works Engineering for Standards.
INC.
98382
GARAGE
1. 00
V-N
1. 00
710028.00
2253.00
2253.00
1. 00
.00
o
Extension
69.00
44.00
11.00
~
vJ
N
~
1:\
~
^
\(J
fJ
~I
r'
"
INSPECTION ELECTRICAL
TYPE DATE: RESULTS: INSPECTOR:
DITCH
SERVICE
ROUGH - IN
FINAL
COMMENTS:
ELECTRICAL PERMIT AND INSPECTION RECORD
CITY OF PORT ANGELES
360-417-4735
Application Number . . . . .
Application pin number
Page 2
Date 10/09/07
07-00000530
861420
Special Notes and Comments
Sanitary sewer connection inspection is required by
Public Works prior to back fill of ditch. 24 hour advance
notice is required.
Construct driveway to City Standards. No concrete with
exposed aggregate allowed in the City road right of way. An
inspection by Public Works Engineering is required prior to
pouring concrete.
Other Fees
SEWER SYSTEM DELV CHARGE
STATE SURCHARGE
PW WATER SYSTEM USE FEE
1000.00
4.50
1230.00
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 124.00 124.00 .00 .00
Plan Check Total .00 .00 .00 .00
Other Fee Total 2234.50 2234.50 .00 .00
Grand Total 2358.50 2358.50 .00 .00
,
.
SPECTION ELECTRICAL
TYPE DATE: RESULTS: INSPECTOR:
DITCH
SERVICE
OUGH - IN
FINAL
OMMENTS:
/M-
G-~'I
</..OU''''o
t:,~~~'
o~.
"'""'" .
11... ae::.;:...;u.
. 'tt> ;:.l'
""'-'
Job wired by
o Electrical Contractor 0 Owner
Electrical contractor name
License number Date Expires
. fiN VLJEJIJ f.J'lc.L Zh3}
IiALvOI? !; EIJ 5 PI i=LlRlc.
Purchaser's' mailing address
?442 PLRr.{: RO
City
PO!?'- A/Jr;~U;.s
Telephone number
State ZIP
\,VA- :3PJ3(;3
FAX number
/f57-'7. (:1.
Premises owner's name
f.:RE};/J /~KtJW
Address of inspection
/'7;7 cJ RoMe OJ71VE
City
P, "" AA/ ' ._, --
O. /'...1"" &>:""J.
Phone number.~ chcdule i
" t> '3
Owner as defined by RCW19.28.26I:(l) Owner will occupy ,he stTllcflIrejor two
years after this electrical permit is finalized. (2) Owner is required /0 hire an electrical
contractor if above said properf)' is for sale, rem or lease.
Arter reading the above statement, I hereby certify that I am the owner of the above
named property or a licensed electrical contractor. I am making the electrical instal-
lation or alteration in compliance with the electrical laws, N.E.C., RCW. Chapter
19.28, WAC. Chapter 296-468, The City of Port Angeles Municipal Code, and
Utility SpecilicJtions.
Signature of owner, electrical contractor or electrical administrator
'-~f '~~9h-R-vf-/ Date: 8. 2..1/0 7
Ele rical Load Additions and or subtractions
o NO LOAD CHANGES
o Baseboard _ KW
X1 Furnace j.1i.. KW
Jlli Heat Pump 3- Ton _ LAR
o Fan-Wall KW
x
I'll
.:.
ELECTRICAL WORK PERMIT APPLICATION
~,
Installation description
o Commercial j1( Residential
ONew
o Altered/Addition
2271') s~ -f'T I~ESlOt::JJr:E
.J //3;'~
)
II -.-!.
Rr:'MDrr-: MP~e.
o Cash 0 Check #
~ Credit Card ~ Mastercard Discover
Card# -ewJ.1i.:E..___---------_
Expiration Date
of card
Inspection fee
.$ /Z1.-
Service Information
o Overhead Service
o Temp Service
Ji{ Underground Service
Voltage /20 / i?4 ()
Phase~ 103
Service Size: PtJC' /l
Feeder Size:
THERMOSTAT
SAME DAY INSPECTION, CALL BEFORE 7:00 AM 360-417-4735
ROUGH-IN
J()/2-3/0/ A-L
DatI: Approved By
Dale
FINAL
~I1,LDf?
DITCH
Appwvcu By
IJ/lfff07
Inspection
Date
Area, Building or Equipment Inspected
10-1.-07
$ 71 3, po aw~
I7ff
. ---. "4:
Approved By
SERVICE
1O/'Z.?>/i:;7 AL
Date Approved By
FEEDER
t;:; By
Dale
Appmvcd By
Action Taken
Electrical
Inspector
AI'
4L
ELECTRICAL INSPECTION
WIRING REPORT
417-4735
ADDRESS
12,cOl"; 'ViZ \ V ~
APPROVED NOT APPROVED
o .................... DITCH. . . . . . . . . . . . . . . . . . . . 0
0". . . . . . . . . . . . . . . ROUGH IN/COVER. . . . . . . . . . . . . . . 0
D. . . . . . . . . . . .. . . . . . . . SERVICE. . .. . . . .. . . . .. . . . ..0
D. .. . . . .. . . . . . . . . . . . . . FINAL. . . .. . . . .. . . . . .. . . .' ~
6rC-l
1J. l'E..C-
(' {Z.oT~ c... \'
2/0. r: crt-
6P\I2At..~
Exc :z
\
\
i2~? . '
c
CORRECTIONS NEEDED:
'Pi r2J'L 1lL-.Af!.- ^
B,lE.-u.-
l^-L/E,c. 110
NOTIFY INSPECTOR WHEN CORRECTIONS
ARE COMPLETED WITHIN 15 DAYS
- DO NOT REMOVE -
OLYMPIC PRINTERS, INC. {360) 452-1361
G - &?
~-"""""'-
$, '.
..--
1.:t~;
'tt-~.t'''
......
..,," ........
ELECTRICAL WORK PERMIT APPLICATION
_,.--7'
,.--
Job wired by
o Electrical Contractor 0 Owner
Installation description
o Commercial )8( Residential
Electrical contractor name License number Date ~xrires
If/iI-VOR5E,A/ $" pl.P.C/./?JC- Ii.lfL v/JERl1"7cL 2/~/{j{
Purchaser's mailing address
2.'1 I) Z. IPt.ACE J?/J
City
ptJ/?r 4J//~E/b-':;
Telephone nu'mbcr
DNew
D Altered/Addition
State ZIP
!F.fl1P' ,r:s.1<I//cE-
.
"....
,......-
jo//J' ~~::J
FAX number
,1
Premises owner's name
CRIEli'N Cl!?PW
Address or inspection
[:IJffJ'f)'Jl i?tJOk Rl7
City
lpl?J" A-UCI3'U$'
I'hone number to schedule inspection:
fjl/lt.O IIJf/ ,
?M/lffil '# I'J"'~ f)
/3d7
.
/2.DO t::-
De.,
Owner as defined by RCW./9.28.26/:(I) Owner wi/! occupy the structure for two
years after Ihis electrical permit is finalized. (2) Owner i.\" required to hire an electrical
contractor if above said property is for sale. relit or lease.
After reading the above statement, I hereby certify that I am the owner of the above
named property or a licensed electrical contractor. I am making the electrical instal.
lation or alteration in compliance with the electrical laws, N.E.C.. RCW. Chapter
19.28, WAC. Chapter 296-468, The City of Port Angeles Municipal Code, and
Utility Speci lications.
Signature of owner, electrical contractor or electrical administrator
o Cash 0 Check #
o Credit Card @.J Mastercard Discover
Card# _.1?/1!L//..S __.____.____
x
~
Date:?; '/4~7
Expiration Date
of card
Inspection fee
$ 40,-
Service Information
Ele rical Load Additions and or subtractions
D NO LOAD CHANGES
o Baseboard KW
o Furnace KW
o Heat Pump Ton LAR
o Fan.Wall KW
o Overhead Service
jll. Temp Service
o Underground Service
Voltage /2d"~dO
Phase~ 1 3
Service Size:
Feeder Size:
SAME DAY INSPECTION, CALL BEFORE 7:00 AM 360-417-4735
ROUGH-IN
THERMOSTAT
SERVICE
Dale
Approved By
Dale
Approved By
Dale
Approved By
FlNAL
1~
DITCH
FEEDER
Do<
Dale Approved By
Dale Approved By
Inspection
Dale
Area, Building or Equipment Inspected
Action Taken
Electrical
Inspector
Cj-13'01
7/3.0G {1",';R4 rz,."C
At
tx
'(i
'I.oO~
CITY OF PORT ANGELES
PUBLIC WORKS - ELECTRICAL DIVISION
321 EAST 5TH STREET. PORT ANGELES. WA 98362
Application Number
Application pin number
Property Address
ASSESSOR PARCEL NUMBER:
Application type description
Subdivision Name
Property Use
Property Zoning . . .
Application valuation
07-00001049 Date
578145
1329 ROOK DR
06-30-14-5-3-0678-0000-
ELECTRICAL ONLY
9/14/07
RS9 RESDNTL SINGLE FAMILY
o
Owner
Contractor
GREEN CROW TIMBER LLC
PO BOX 2439
PORT ANGELES WA 983620312
HALVORSEN ELECTRIC
1426 W 11TH ST
PORT ANGELES WA 98363
(360) 457-7803
Permit . . . . .
Additional desc .
Permit pin number
Sub Contractor
Permit Fee
Issue Date
Expiration Date
ELECTRICAL TEMPORARY SERVICE
HALVORSEN/ 60A TEMP SVC
110791
HALVORSEN ELECTRIC
40.00 Plan Check Fee
9/14/07 Valuation
3/12/08
.00
o
.........
.~
~
-0
Qty Unit Charge Per
1.00 40.0000 ECH EL-TEMP SRV - 0-60 SRV FDR
Extension
40.00
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 40.00 40.00 .00 .00
Plan Check Total .00 .00 .00 .00
Grand Total 40.00 40.00 .00 .00
~
()
'It
~
COMMENTS/ACTION NEEDED
~
ELECfRICAL PERMIT INSPECfION .RECORD
CALL 417-4735 FOR ELECTRICAL INSPECTIONS. PLEASE PR0VIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLA WFUL TO COVER,
INSULA TE OR CONCEAL ANY WORK BEFORE IT IS INSPECTED AND ACCEPTED.
KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE
INSPECTION TYPE
DATE
COMMENTS
NO
/:.
/~ 5v'c-
GENERAL COMMENTS:
PW-lI02.1S (4'96)
~
ELECTRICAL PERMIT
CITY OF PORT ANGELES
360 -417 -4735
Application Number . . . . . 1
15- 00001464 pate 1
11/04/15
Application pin number . , , 2
230504
Property Address , , . , 1
1329 ROOK DR
ASSESSOR PARCEL NUMBER: 0
06-30-14-7-2- 0080 -0000-
Application type description E
ELECTRICAL ONLY
Subdivision Name , , , . . .
Property Use
Property Zoning . . . . . . . R
RS9 RESDNTL SINGLE FAMILY
Application valuation , . . . 0
0
Application desc
Alteration
Owner C
Contractor
LON E AND DONNA E KOLLATH J
JEFF NELSON ELECTRIC
13.29 ROOK DR 7
7062 OLD OLYMPIC HWY.
PORT ANGELES WA.95362 P
PORT ANGELES WA 9
98352
(360) 461 -9868 (
(369) 460 -4291
REPORT SALES TAX
on your excise tax form
to the City of Port Angeles
(Location Code 0502)
INSPECTION TYPE DATE: RESULTS: INSPECTOR:
DITCH
SERVICE
ROUGH -IN C°
.FINAL
COMMENTS:
PERMIT WILL EXPIRE SIX (6) MONTHS FROM LAST INSPECTION
Signature of owner or Electrical Contra_ ctor X
G:IEXCHANGEIB UILDING
Date:
v11
~�
PERMIT WILL EXPIRE SIX (6) MONTHS FROM LAST INSPECTION
Signature of owner or Electrical Contra_ ctor X
G:IEXCHANGEIB UILDING
Date:
v11
~�
FROM : FAX NO. :6814254 Nov. 04 2015 08:01AM P1
C'IT'Y OF PORT ANGELES PERMIT APPLICATION
Building Division/Electrical Inspections
321 mast Fifth Street — P.O. Box 115411 Port Ange %s Washington, 98362
Ph: (360) 417 -473; Fax: (360) 417 -4711
Date:
Zl& 2 Single Family Dwelling
* Plan Review Ma Be Require Please Cam ate Electrical Plan Revlew Information Sheet
Job Address:
Building Square Footage; "._.�
Description of above z-- llr--IEZ77_
OwnerInformo n
Narna: T"�'
Mailing Address b
_
City, state: Zp:
Phone: f=ax:
Uoense # 1 Exp,
RN
Unit Chase
SeNicelFeeder 200 Amp,
$120.00
SenrloelFeeder 201.400 Amp.
$ 146,00
ServioefFeeder 401.600 Amp
$ 205.00
Servloe/Feeder 601 1000 Amp.
$ 262.00
Servioe/Foeder over 1000 Amp.
$ 373.00
Branch Circuit Wl Service Feeder
$ 5,00
Branch Circuit WIO Service Feeder
$ 63,00
Each Additional Branch Circuit
$
Branch Cir+cuite 1-4
75,0
Temp. Service/ Feeder 200 Amp,
0
Temp. Service/Feeder 201-400 Amp.
$110,00
Temp. Servlce/Feeder 401 -600 Amp.
$149,00
Temp. $ervice/Feeder 601 -1000 Amp .
$ 168.00
Portal to Portal Hourly
$ 96.00
51904 Circuit! Limited Ervigy -1 & 2 Family Dwelling
$ 64,00
Manufactured Nome Connection
$120,00
Renewable Electrical Energy - 5KVA System or Less
$102.00
Thermostat
$ 56,00
Note: $5,00 for each additlonal T-Stat
NEW CONSTRUCTION ONLY:
First 1300 Square Ft.
$120.00
Each Additional 500 Square Ft. or Portion of
$ 40.00
Each Outbuilding or Detached Garage
$ 74,00
Each Swimming pool or Hot Tub
$ 410.00
Contractor Informatio
Name:
Mailing Address:
City -S State; 2•ip_ - -
Phony: 22 I Fare, Ca �t
License 01 Fxp. d r-7,4zAfC-jC-
(k ( Total (ft Wftlitg by Unit Chang
$
$ Total
Owner as defined by RCW.19.26.261: (1) Owner will occupy the structure for two years alter this electrical permit is finalized. (2) Owner is required
to hive an electrical contractor if above said property is for sale, rent or lease. Permit expires after six months of last inspection,
After reading the above statement, I hereby certify that I ant the owner of the above named property or a licensed electrical contractor. I am making
the electrical installation or alteration in compliance with the electrical laws, N.E.C., RCW. Chapter 19,26, WAC. Chapter 296-46B, The City of Port
Angeles Municipal Code, and Utility Spectftcations and PAMC 14. 05,050 regarding Electrical Permit Applications.
Signature of owner, electrical contractor or olectirical admini*ator: ❑ Cmih ❑ Chma
Gedk Card # __ _
X Leh Dated: ! /
4—