HomeMy WebLinkAbout3501 Bldg D W 18th St - Scale Shack - Building ELECTRICAL PERMIT
CITY OF PORT ANGELES
360 417 -4735
Application Number 12- 00000065 Date 2/21/12
Application pin number 207475
Property Address 3501 BLDG D W 18TH ST REPORT SALES TAX
ASSESSOR PARCEL NUMBER: 07- 30- 01 -2 -2- 0000 -0000 on your excise tax form
Application type description ELECTRICAL ONLY
Subdivision Name to the City of Port Angeles
Property Use (Location Code 0502)
Property Zoning UNKNOWN.
Application valuation 0
Application desc
Generator panel and 3 circuits for lights
c
Owner Contractor
'CITY OF PORT ANGELES OWNER
PO BOX 1150
PORT ANGELES WA 983620217
Permit ELECTRICAL ALTER COMMERCIAL
Additional desc
Permit Fee 197.00 Plan Check Fee .00
Issue Date. 2/21/12 Valuation 0
Expiration Date 8/19/12
Qty Unit Charge Per Extension
1.00 74.0000 ECH EL -COMM BRANCH CIR WO/ S/F 74.00
2.00 5.0000 ECH EL -ECH ADDNT BRANCH CIRCUIT 10.00
1.00• 113.0000 ECH EL- COMM RENEWABLE 5KVA -LESS 113.00
Fee summary Charged Paid Credited Due
Permit Fee Total 197.00 197.00 .00 .00
Plan Check Total .00 .00 .00 .00
Grand Total 197.00 197.00 .00 .00
2
L9
INSPECTION TYPE DATE: RESULTS: INSPECTOR:
DITCH
SERVICE
ROUGH IN �Z )'7 4 1 f40
FINAL Z
COMMENTS:
PERMIT WILL EXPIRE SIX (6) MONTHS FROM LAST INSPECTION
Signature of owner or Electrical Contractor X Date:
G: \EXCHANGE \BUILDING
ill\ ttlkr t N
1 E •1 1
CITY OF PORT ANGELES PERMIT APPLICATION
Building Division /Electrical Inspections JAN 2 4 2011
321 East Fifth Street P.O. Box 1150 Port Angeles Washington, 98362
Ph: (360) 417 -4735 Fax: (360) 417 -4711 ELECTRICAL
INSPECTIONS
Date: 1(2' l 2- Multi Family or Commercial*
Plan Review May Be Required, Please Complete Electrical Plan Review Information Sheet
Job Address: 3501 I, le Gci-,L_,a___ 1V
Building Square Footage:
Description of above jviih j O 12- !.J)7(J- 1
Owner Information Contractor Information
Name: c...) T 1
.I Q f p Name:
Mailing Address: 3 Z) l5 S Mailing Address:
City: Q p- State: W t Zip: 9 j City: State: Zip:
Phone: Q/7 i Phone: Fax:
License Exp. License Exp.
Item Unit Charge Qty Total (Qty Multiplied by Unit Charge)
Service /Feeder 200 Amp. 132.00
Service /Feeder 201 -400 Amp. 160.00
Service /Feeder 401 -600 Amp 225.00
Service /Feeder 601 -1000 Amp. 288.00
Service /Feeder over 1000 Amp. 410.00
Branch Circuit W/ Service Feeder 5.00
Branch Circuit W/O Service Feeder 74.00
Each Additional Branch Circuit 5.00 Z LJ
Branch Circuits 1-4 86.00j i
Temp. Service/ Feeder 200 Amp. 102.00
Temp. Service /Feeder 201 -400 Amp. 121.00
Temp. Service /Feeder 401 -600 Amp. 164.00
Temp. Service /Feeder 601 -1000 Amp 185.00
Portal to Portal Hourly 96.00
Sign /Outline Lighting 88.00
Signal Circuit/ Limited Energy Multi- Family 64.00
Signal Circuit/ Limited Energy First 1500 sf Commercial 96.00
Note: $5.00 for each additional 1500 sf
Renewable Electrical Energy 5KVA System or Less 113.00 1 113
Thermostat 56.00
Note: $5.00 for each additional T -Stat U(,
6 7 Total
Owner as defined by RCW.19.28.261: (1) Owner will occupy the structure for two years after this electrical permit is finalized. (2) Owner is required
to hire an electrical contractor if above said property is for sale, rent or lease. Permit expires after six months of last inspection.
After reading the above statement, I hereby certify that I am the owner of the above named property or a licensed electrical contractor. I am making
the electrical installation oralteration in compliance with the electrical laws, N.E.C., RCW. Chapter 19.28, WAC. Chapter 296 -46B, The City of Port
Angeles Municipal Code, and Utility Specifications and PAMC 14.05.050 regarding Electrical Permit Applications.
Signature of owner, electrical contractor or electrical administrator: Cash Check
Credit Card
1 z
(e Dated: 0110112012
PREPARED 9/20/06 10 27 22 INSPECTION TICKET PAGE 8
CITY OF PORT ANGELES INSPECTOR JAMES L LIERLY DATE 9/20/06
ADDRESS 3501 BLDG D W 18TH ST SUBDIV
TENANT NBR CITY OF PORT ANGELES
CONTRACTOR E T ENVIRONMENTAL PHONE (404) 926 1776
OWNER CITY OF PORT ANGELES PHONE
PARCEL 07 30 01 2 2 0000 0000
APPL NUMBER 06 00000280 COMM NEW CONST
PERMIT BPC 00 BUILDING PERMIT COMMERCIAL
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
BL3 01 5/19/06 JLL BUILDING FRAMING TIME 13 00
5/19/06 DA OVERRIDE TAKEN BY DYASUMUR DATE 05/18/06 TIME 14 30 29
05/18/2006 02 30 PM DYASUMUR
paul 271 2301
05/19/2006 03 48 PM JLIERLY
address to be posted on site /staff building plans
reqd /detail for fire wall in building north of transfer
station /j11
BL3 02 5/23/06 JLL BUILDING FRAMING TIME 13 00
5/23/06 AP OVERRIDE TAKEN BY DYASUMUR DATE 05/22/06 TIME 13 40 05
CHARLIE 276 2301 05/22/2006 01 39 PM DYASUMUR
05/23/2006 04 17 PM JLIERLY
BLI 01 5/24/06 JLL BUILDING INSULATION TIME 13 00
5/25/06 AP OVERRIDE TAKEN BY DYASUMUR DATE 05/23/06 TIME 13 35 58
CHARLIE 271 2301 05/23/2006 01 35 PM DYASUMUR
05/25/2006 08 16 AM JLIERLY
PW99 01 8/30/06 DWM PUBLIC WORKS FINAL
8/30/06 AP OVERRIDE TAKEN BY RVESS DATE 09/11/06 TIME 10 30 44
09/11/2006 10 30 AM RVESS
09/11/2006 10 31 AM RVESS
BL99 01 8/30/06 JLL BUILDING FINAL TIME 13 00
8/30/06 DA OVERRIDE TAKEN BY DYASUMUR DATE 08/29/06 TIME 14 56 58
08/30/2006 03 11 PM JLIERLY
stairs at transfer station require a hand rail /address
letters on all buildings /haz waste building require the t &p
line to be to the exterior/ letter from eng on columns /seal
sprinkler line in haz waste building /notified contractor
that the elec meter and water meters are supposed to be one
each for each building per contract/j11
BL99 02 9/07/06 JLL BUILDING FINAL TIME 13 00
9/08/06 DA OVERRIDE TAKEN BY DYASUMUR DATE 09/06/06 TIME 14 27 52
JERRY 206 793 7198
09/06/2006 02 27 PM DYASUMUR
09/08/2006 08 09 AM JLIERLY
all items are completeexcept electrical final required
before bldg final can be approved jll
BL99 03 9/20 06 L BUILDING FINAL TIME 13 00
OVERRIDE TAKEN BY DYASUMUR DATE 09/20/06 TIME 09 19 54
09/20/2006 09 19 AM DYASUMUR
COMMENTS AND NOTES
PREPARED 9/07/06 11 10 06 INSPECTION TICKET PAGE 12
CITY OF PORT ANGELES INSPECTOR JAMES L LIERLY DATE 9/07/06
ADDRESS 3501 BLDG D W 18TH ST SUBDIV
TENANT NBR CITY OF PORT ANGELES
CONTRACTOR E T ENVIRONMENTAL PHONE (404) 926 1776
OWNER CITY OF PORT ANGELES PHONE
PARCEL 07 30 01 2 2 0000 0000
APPL NUMBER 06 00000280 COMM NEW CONST
PERMIT BPC 00 BUILDING PERMIT COMMERCIAL
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
BL3 01 5/19/06 JLL BUILDING FRAMING TIME 13 00
5/19/06 DA OVERRIDE TAKEN BY DYASUMUR DATE 05/18/06 TIME 14 30 29
05/18/2006 02 30 PM DYASUMUR
paul 271 2301
05/19/2006 03 48 PM JLIERLY
address to be posted on site /staff building plans
reqd /detail for fire wall in building north of transfer
station /j11
BL3 02 5/23/06 JLL BUILDING FRAMING TIME 13 00
5/23/06 AP OVERRIDE TAKEN BY DYASUMUR DATE 05/22/06 TIME 13 40 05
CHARLIE 276 2301 05/22/2006 01 39 PM DYASUMUR
05/23/2006 04 17 PM JLIERLY
BLI 01 5/24/06 JLL BUILDING INSULATION TIME 13 00
5/25/06 AP OVERRIDE TAKEN BY DYASUMUR DATE 05/23/06 TIME 13 35 58
CHARLIE 271 2301 05/23/2006 01 35 PM DYASUMUR
05/25/2006 08 16 AM JLIERLY
BL99 01 8/30/06 JLL BUILDING FINAL TIME 13 00
8/30/06 DA OVERRIDE TAKEN BY DYASUMUR DATE 08/29/06 TIME 14 56 58
JAN 206 793 4198
08/29/2006 02 56 PM DYASUMUR
08/30/2006 03 11 PM JLIERLY
stairs at transfer station require a hand rail /address
letters on all buildings /haz waste building require the t &p
line to be to the exterior/ letter from eng on columns /seal
sprinkler line in haz waste building /notified contractor
that the elec meter and water meters are supposed to be one
each for each building per contract/j11
BL99 02 9/07/06 7I. BUIVEIRG EITAL BIME 13 00
LC OVERRIDE TAKEN BY DYASUMUR DATE 09/06/06 TIME 14 27 52
JERRY 206 793 7198
09/06/2006 02 27 PM DYASUMUR
COMMENTS AND NOTES
BUILDING DIVISION
CITY OF PORT ANGELES
Correction Notice
Job Located at 2�� LN 1 S
Inspection of your work revealed that the following is
not in accordance with the codes governing the work in
this jurisdiction
-1 l e"(40 lam^ W r St S
c_c2
1c cY-
U
73-- too
t—diet-e c 4.az
These corrections must be made and are not to be
covered until reinspection is made When corre9lions
have been made, please call
for inspection I f
Date
g
`4
nn NJAT RFIUMAVF TWIG TAO:
Inspector for Building Division
PREPARED 8/30/06 8 31 56 INSPECTION TICKET
CITY OF PORT ANGELES
ADDRESS
TENANT NBR
CONTRACTOR
OWNER
PARCEL
APPL NUMBER
PERMIT
TYP /SQ
BL3 01
BPC 00 BUILDING PERMIT
REQUESTED INSP
COMPLETED RESULT
5/19/06 JLL
5/19/06 DA
BL3 02 5/23/06 JLL
5/23/06 AP
BLI 01 5/24/06 JLL
5/25/06 AP
BL99 01 8/30/06 JLL
(?1
COMMERCIAL
DESCRIPTION
RESULTS /COMMENTS
INSPECTOR JAMES L LIERLY
3501 BLDG D W 18TH ST SUBDIV
CITY OF PORT ANGELES
E T ENVIRONMENTAL PHONE (404) 926 1776
CITY OF PORT ANGELES PHONE
07 30 01 2 2 0000 0000
06 00000280 COMM NEW CONST
BUILDING FRAMING TIME 13 00
OVERRIDE TAKEN BY DYASUMUR DATE
05/18/2006 02 30 PM DYASUMUR
paul 271 2301
05/19/2006 03 48 PM JLIERLY
address to be posted on site /staff building
regd /detail for fire wall in building north
station /j11
BUILDING FRAMING TIME 13 00
OVERRIDE TAKEN BY DYASUMUR DATE
CHARLIE 276 2301 05/22/2006 01 39
05/23/2006 04 17 PM JLIERLY
BUILDING INSULATION TIME 13 00
OVERRIDE TAKEN BY DYASUMUR DATE
CHARLIE 271 2301 05/23/2006 01 35
COMMENTS AND NOTES
PAGE 37
DATE 8/30/06
05/18/06 TIME 14 30 29
plans
of transfer
05/22/06 TIME 13
PM DYASUMUR
05/23/06 TIME 13
PM DYASUMUR
40 05
35 58
05/25/2006 08 16 AM JLIERLY
BUILDING FINAL TIME 13 00
OVERRIDE TAKEN BY DYASUMUR DATE 08/29/06 TIME 14 56 58
JAN 206 793 4198
08/29/2006 02 56 PM DYASUMUR
PREPARED 8/04/06 8 14 25 INSPECTION TICKET PAGE 25
CITY OF PORT ANGELES INSPECTOR JAMES L LIERLY DATE 8/04/06
ADDRESS 3501 BLDG D W 18TH ST SUBDIV
TENANT NBR CITY OF PORT ANGELES
CONTRACTOR E T ENVIRONMENTAL PHONE (404) 926 1776
OWNER CITY OF PORT ANGELES PHONE
PARCEL 07 30 01 2 2 0000 0000
APPL NUMBER 06 00000280 COMM NEW CONST
PERMIT PL 00 PLUMBING PERMIT
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
PL99 01 8/04/06 JLL PLUMBING FINAL TIME 13 00
V4 MIKE 226 255 9744
08/03/2006 03 40 PM DYASUMUR
COMMENTS AND NOTES
PREPARED 7/18/06 9 59 32
INSPECTION TICKET PAGE 13
CITY OF PORT ANGELES INSPECTOR JAMES L LIERLY DATE 7/18/06
ADDRESS 3501 BLDG D W 18TH ST SUBDIV
TENANT NBR CITY OF PORT ANGELES
CONTRACTOR E T ENVIRONMENTAL PHONE (404) 926 1776
OWNER CITY OF PORT ANGELES PHONE
PARCEL 07 30 01 2 2 0000 0000
APPL NUMBER 06 00000280 COMM NEW CONST
PERMIT ME 00 MECHANICAL PERMIT
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
ME99 01 7/18/06
JLL
MECHANICAL FINAL TIME 13 00
ERIC 206 793 4198
07/17/2006 02 18 PM DYASUMUR
COMMENTS AND NOTES
PREPARED 5/24/06 12 23 11 INSPECTION TICKET PAGE 8
CITY OF PORT ANGELES INSPECTOR JAMES L LIERLY DATE 5/24/06
ADDRESS 3501 BLDG D W 18TH ST SUBDIV
TENANT NBR CITY OF PORT ANGELES
CONTRACTOR E T ENVIRONMENTAL PHONE (404) 926 1776
OWNER CITY OF PORT ANGELES PHONE
PARCEL 07 30 01 2 2 0000 0000
APPL NUMBER 06 00000280 COMM NEW CONST
PERMIT BPC 00 BUILDING PERMIT COMMERCIAL
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
BL3 01 5/19/06 JLL BUILDING FRAMING TIME 13 00
5/19/06 DA OVERRIDE TAKEN BY DYASUMUR DATE 05/18/06 TIME 14 30 29
05/18/2006 02 30 PM DYASUMUR
paul 271 2301
05/19/2006 03 48 PM JLIERLY
address to be posted on site /staff building plans
reqd /detail for fire wall in building north of transfer
station /j11
BL3 02 5/23/06 JLL BUILDING FRAMING TIME 13 00
5/23/06 AP OVERRIDE TAKEN BY DYASUMUR DATE 05/22/06 TIME 13 40 05
CHARLIE 276 2301 05/22/2006 01 39 PM DYASUMUR
BLI 01 24/,0
05/23/2006 04 17 PM JLIERLY
BUILDING INSULATION TIME 13 00
OVERRIDE TAKEN BY DYASUMUR DATE 05/23/06 TIME 13 35 58
CHARLIE 271 2301 05/23/2006 01 35 PM DYASUMUR
COMMENTS AND NOTES
S c_..a._'e
PREPARED 5/23/06 11 02 06 INSPECTION TICKET PAGE 11
CITY OF PORT ANGELES INSPECTOR JAMES L LIERLY DATE 5/23/06
ADDRESS 3501 BLDG D W 18TH ST SUBDIV
TENANT NBR CITY OF PORT ANGELES
CONTRACTOR E T ENVIRONMENTAL PHONE (404) 926 1776
OWNER CITY OF PORT ANGELES PHONE
PARCEL 07 30 01 2 2 0000 0000
APPL NUMBER 06 00000280 COMM NEW CONST
PERMIT BPC 00 BUIL DIN G PERMIT COMMERCIAL
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
BL3 01 5/19/06 JLL BUILDING FRAMING TIME 13 00
5/19/06 DA OVERRIDE TAKEN BY DYASUMUR DATE 05/18/06 TIME 14 30 29
05/18/2006 02 30 PM DYASUMUR
paul 271 2301
05/19/2006 03 48 PM JLIERLY
address to be posted on site /staff building plans
reqd /detail for fire wall in building north of transfer
station /j11
BL3 02 5/ 3� JLL BUIVEIRG ERTAIEN TIME 13 00
OVERRIDE TAKEN BY DYASUMUR DATE 05/22/06 TIME 13 40 05
CHARLIE 276 2301 05/22/2006 01 39 PM DYASUMUR
COMMENTS AND NOTES
PREPARED 5/19/06 10 58 48 INSPECTION TICKET PAGE 6
CITY OF PORT ANGELES INSPECTOR JAMES L LIERLY DATE 5/19/06
ADDRESS 3501 BLDG D W 18TH ST SUBDIV
TENANT NBR CITY OF PORT ANGELES
CONTRACTOR E T ENVIRONMENTAL PHONE (404) 926 1776
OWNER CITY OF PORT ANGELES PHONE
PARCEL 07 30 01 2 2 0000 0000
APPL NUMBER 06 00000280 COMM NEW CONST
PERMIT BPC 00 BUILDING PERMIT COMMERCIAL
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
BL3 01
44V00
BUILDING FRAMING TIME 13 00
OVERRIDE TAKEN BY DYASUMUR DATE 05/18/06 TIME 14 30 29
05/18/2006 02 30 PM DYASUMUR
paul 271 2301
COMMENTS AND NOTES
VORi
Application Number
Application pin number
Property Address
ASSESSOR PARCEL NUMBER
Tenant nbr name
Application type description
Subdivision Name
Property Use
Property Zoning
Application valuation
Owner
CITY OF PORT ANGELES
PO BOX 1150
PORT ANGELES
Permit MECHANICAL PERMIT
Additional desc
Permit pin number 76448
Permit Fee 93 90
Issue Date 5/09/06
Expiration Date 11/05/06
Qty Unit Charge Per
Permit PLUMBING PERMIT
Signature of Contractor or Authorized Agent
T \Policies \1102 15 building permit inspection record05.wpd [1/4/2005]
CITY OF PORT ANGELES
DEPARTMENT OF COMMUNITY DEVELOPMENT BUILDING DIVISION
321 EAST 5TH STREET PORT ANGELES, WA 98362
06 00000280 Date 5/18/06
974240
3501 BLDG D W 18TH ST
07 30 01 2 2 0000 0000
CITY ST PORT ANGELES
COMM NEW CON 0
ST N C� �7s.�
UNKNOWN /�v l O
86700
Contractor
E T ENVIRONMENTAL
3424 PECHTREE RD NE STE 150
WA 983620217 ATLANTA GA 30327
(404) 926 1776
Structure Information 000 000 1
Other struct info TOTAL LOT COVERAGE
CONSTRUCTION TYPE
HARD SURFACE AREA
NUMBER OF STORIES
EXISTING LOT COVERAGE
LOT SIZE
PROPOSED LOT COVERAGE
TOTAL LOT COVERAGE
NUMBER OF UNITS
Permit ELECTRICAL NEW COMMERICAL
Additional desc
Permit pin number 76455
Permit Fee 47 80 Plan Check Fee
Issue Date 5/09/06 Valuation
Expiration Date 11/05/06
Qty Unit Charge Per
1 00 36 4000 ECH EL -LVT FIRST THERMOSTAT
1 00 11 4000 ECH EL -LVT ADD THERMOSTAT
Valuation
BASE FEE
2 00 14 7000 ECH ME INSTALL 100- FAU
2 00 7 2500 ECH ME VENT FAN
1
1
1 00
1 00
1 00
1 00
1 00
1 00
1 00
Permit BUILDING PERMIT COMMERCIAL
Additional desc
Permit pin number 77834
Permit Fee 00 Plan Check Fee 00
Issue Date 5/18/06 Valuation 86700
Expiration Date 11/14/06
00
0
Extension
36 40
11 40
Plan Check Fee 00
0
Extension
50 00
29 40
14 50
Date Signature of Owner (if owner is builder)
Separate Permits are required for electrical work, SEPA, Shoreline, ESA, utilities, private and public improvements. This permit becomes E
null and void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned
for a period of 180 days after the work as commenced or if required inspections have not been requested within 180 days from the last M
inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of
laws and ordinances goveming this type of work will be complied with whether specified herein or not. The granting of a permit does not
presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of S►
construction.
k",
CALL 417 -4815 FOR BUILDING INSPECTIONS. CALL 417 -4735 FOR ELECTRICAL INSPECTIONS.
CALL 417 -4807 FOR PUBLIC WORKS UTILITIES
PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE
INSPECTED AND ACCEPTED. POST PERMIT IN A CONSPICUOUS LOCATION
KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE.
INSPECTION TYPE DATE ACCEPTED COMMENTS
FOUNDATION:
FOOTINGS
SHEAR WALLS WALLS
FOUNDATION DRAINAGE DOWN SPOUTS
PIERS
POST HOLES (POLE BLDGS.)
PLUMBING
UNDER FLOOR SLAB
ROUGH -IN
WATER LINE (METER TO BLDG)
GAS LINE
BACK FLOW WATER
AIR SEAL
WALLS
CEILING
FRAMING
JOISTS GIRDERS
SHEAR WALL/HOLD DOWNS
WALLS ROOF CEILING
DRYWALL (INTERIOR BRACED PANEL ONLY)
T -BAR
INSULATION
SLAB
WALL FLOOR CEILING
MECHANICAL
HEAT PUMP FURNACE DUCTS
GAS LINE
WOOD STOVE PELLET CHIMNEY
COMMERCIAL HOOD DUCTS
MANUFACTURED HOMES
FOOTING SLAB
BLOCKING HOLD DOWNS
SKIRTING
ELECTRICAL LIGHT DEPT
CONSTRUCTION R.W PW/
ENGINEERING 417 -4807
FIRE 417 -4653 I
PLANNING DEPT 417 -4750 I
BUILDING 417 -4815 1
T \Policies \1102_15 building permit inspection record05 wpd [1/4/2005]
BUILDING PERMIT INSPECTION RECORD
YES NO
FINAL
FINAL
PLANNING DEPT SEPARATE PERMIT #'s SEPA.
PARKING /LIGHTING 1 I I ESA.
LANDSCAPING I I I SHORELINE.
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE
RESIDENTIAL DATE YES NO COMMERCIAL DATE ACCEPTED
YES 1 NO
417 -4735 ELECTRICAL
LIGHT DEPT
CONSTRUCTION R.W
PW ENGINEERING
I FIRE DEPT
I PLANNING DEPT
1 BUILDING
DATE ACCEPTED BY.
DATE ACCEPTED BY.
I 1 1
1 1 1
1 1 1
•r
CITY OF PORT ANGELES
DEPARTMENT OF COMMUNITY DEVELOPMENT BUILDING DIVISION
321 EAST 5TH STREET PORT ANGELES, WA 98362
Page 2
Application Number 06 00000280 Date 5/18/06
Application pin number 974240
Additional desc
Permit pin number 76430
Permit Fee 107 00 Plan Check Fee 00
Issue Date 5/09/06 Valuation 0
Expiration Date 11/05/06
Qty Unit Charge Per Extension
BASE FEE 50 00
4 00 7 0000 ECH PL- EA FIXTURE ON ONE TRAP 28 00
1 00 7 0000 ECH PL EA INSTALL WATER PIPE 7 00
1 00 15 0000 ECH PL EA BLDG SEWER 15 00
1 00 7 0000 ECH PL EA WATER HEATER 7 00
Special Notes and Comments
Sanitary sewer connection inspection is required by
Public Works prior to back fill of ditch 24 hour advance
notice is required
Other Fees SEWER SYSTEM DELV CHARGE 870 00
STATE SURCHARGE 4 50
PW WATER SYSTEM USE FEE 1200 00
Fee summary Charged Paid Credited Due
Permit Fee Total 248 70 248 70 00 00
Plan Check Total 00 00 00 00
Other Fee Total 2074 50 2074 50 00 00
wt Grand Total 2323 20 2323 20 00 00
Separate Permits are required for electrical work, SEPA, Shoreline, ESA, utilities, private and public improvements. This permit becomes
null and void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned
for a period of 180 days after the work as commenced or if required inspections have not been requested within 180 days from the last
inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of
laws and ordinances goveming this type of work will be complied with whether specified herein or not. The granting of a permit does not
presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construction.
Signature of Contractor or Authorized Agent Date Signature of Owner (if owner is builder) Date
T• \Policies \1102_15 building permit inspection record05 wpd [1/4/2005]
't%
CALL 417 -4815 FOR BUILDING INSPECTIONS. CALL 417 -4735 FOR ELECTRICAL INSPECTIONS.
CALL 417 -4807 FOR PUBLIC WORKS UTILITIES
PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE
INSPECTED AND ACCEPTED. POST PERMIT IN A CONSPICUOUS LOCATION
KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE.
INSPECTION TYPE DATE ACCEPTED COMMENTS
FOUNDATION:
FOOTINGS
SHEAR WALLS WALLS
FOUNDATION DRAINAGE DOWN SPOUTS
PIERS
POST HOLES (POLE BLDGS.)
PLUMBING
UNDER FLOOR SLAB
ROUGH -IN
WATER LINE (METER TO BLDG)
GAS LINE
BACK FLOW WATER
AIR SEAL
WALLS
CEILING
FRAMING
JOISTS GIRDERS
SHEAR WALL /HOLD DOWNS
WALLS ROOF CEILING
DRYWALL (INTERIOR BRACED PANEL ONLY)
T -BAR
INSULATION
SLAB
WALL FLOOR CEILING
MECHANICAL
HEAT PUMP FURNACE DUCTS
GAS LINE
WOOD STOVE PELLET CHIMNEY
COMMERCIAL HOOD DUCTS
MANUFACTURED HOMES
FOOTING SLAB
BLOCKING HOLD DOWNS
SKIRTING
PLANNING DEPT SEPARATE PERMIT #'s
PARKING /LIGHTING
LANDSCAPING
RESIDENTIAL
ELECTRICAL LIGHT DEPT
CONSTRUCTION R.W PW/
ENGINEERING 417 -4807
FIRE 417 -4653
PLANNING DEPT 417 -4750 I
BUILDING 417 -4815 I
T \Policies \1102_15 building permit inspection record05 wpd [1/4/2005]
BUILDING PERMIT INSPECTION RECORD
i
6 /AbI
I I
1
•6 1 724/
1 1
1 1 1
tS 7 AP 0(o 1 7 1,
1
1
1 FINAL /r 2 DATE V—A— ACCEPTED BY.
1
1
1
1
1
YES 1 NO
417 -4735 ELECTRICAL
LIGHT DEPT
FINAL /I/ /0 6 DATE J—L ACCEPTED BY.
SEPA.
ESA.
SHORELINE.
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE
DATE YES NO COMMERCIAL DATE ACCEPTED
YES 1 NO
CONSTRUCTION R.W
PW ENGINEERING
FIRE DEPT
PLANNING DEPT
BUILDING
1 1 I
q /Z Z
S
Application Number
Application pin number
Property Address
ASSESSOR PARCEL NUMBER
Tenant nbr name
Application type description
Subdivision Name
Property Use
Property Zoning
Application valuation
Owner
CITY OF PORT ANGELES
PO BOX 1150
PORT ANGELES
Permit
Additional desc
Permit pin number
Permit Fee
Issue Date
Expiration Date
Permit
Additional desc
Permit pin number
Permit Fee
Issue Date
Expiration Date
Other Fees
Fee summary Charged
T•\Policies \1102.15R [1/05]
75556
715 00
75564
110 00
11/05
11/05/06
CITY OF PORT ANGELES
PUBLIC WORKS UTIL1ITS DIVISION
321 EAST5TH STREET PORT ANGELES, WA 98362
06 00000280
974240
3501 BLDG D W 18TH ST
07 30 01 2 2 -0000 0000
CITY OF PORT ANGELES
COMM NEW CONST
UNKNOWN
86700
E T ENVIRONMENTAL
3424 PECHTREE RD NE STE 150
WA 983620217 ATLANTA GA 30327
(404) 926 1776
Structure Information 000 000 1
Other struct info TOTAL LOT COVERAGE 1 00
CONSTRUCTION TYPE 1
HARD SURFACE AREA 1
NUMBER OF STORIES 1 00
EXISTING LOT COVERAGE 1 00
LOT SIZE 1 00
PROPOSED LOT COVERAGE 1 00
TOTAL LOT COVERAGE 1 00
NUMBER OF UNITS 1 00
PUBLIC WORKS COMM WATER SERV
SANITARY SEWER HOOK UP
Contractor
Qty Unit Charge Per
1 00 110 0000 EA SAN SEWER HOOKUP
Plan Check Fee
Valuation
Qty Unit Charge Per
1 00 715 0000 EA PW W/M 1 SERV 5/8 METER
Plan Check Fee
Valuation
Special Notes and Comments
Sanitary sewer connection inspection is required by
Public Works prior to back fill of ditch 24 hour advance
notice is required
SEWER SYSTEM DELV CHARGE
STATE SURCHARGE
PW WATER SYSTEM USE FEE
Paid Credited Due
Date 5/09/06
00
0
Extension
715 00
Extension
110 00
870 00
4 50
1200 00
00
0
Separate Permits are required forelectrical work, SEPA, Shoreline, ESA, utilities, private and public improvements. This permit becomes
null and void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned
for a period of 180 days after the work as commenced, or if required inspections have not been requested within 180 days from the last
inspection. I hereby certify that 1 have read and examined this application and know the same to be true and correct. All provisions of
laws and ordinances goveming this type of work will be complied with whether specified herein or not. The granting of a permit does not
presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
constru
Signature of Contractor or Authorized Agent 'Oate Signature of Owner (if owner -is builder) Date
CALL 417 -4807 FOR UTILITY INSPECTIONS. PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAWFUL TO COVER,
INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT IN A CONSPICUOUS LOCATION.
PW UTILITIES (Engineering Division)
WATERLINE METER
SEWER CONNECTION
SANITARY
STORM
SITE DRAINAGE
SITE EROSION CONTROL
PARKING
SIDEWALK
CURB GUTTER
DRIVEWAY APPROACH
BACK -FLOW DEVICE
RESIDENTIAL
CONSTRUCTION RW PW/ 417 4807
ENGINEERING
FIRE 417 -4653
PLANNING DEPT 417 -4750
BUILDING 417 -4815
TAPolicies \1102.15R (1/05)
PERMIT INSPECTION RECORD
KEEP PERMIT CARD AND APPROVED PLANS AT J013 SITE
INSPECTION TYPE DATE ACCEPTED
YES 1 NO
1 1
1 1
1 1 1
1 1
1 1
1 1 1
1 1 1
1 1 1
1 1
1 1 1
1 1
1 1 1
1 1
1 1
1 1 1
1 1
1 1 1
1 1 1
1 1 1
1 1 1
1 1
1
i 1
1 1 1
1 1 1
1 1 .1
COMMENTS
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE
DATE YES NO COMMERCIAL DATE ACCEPTED
YES 1 NO
1 1
1 1
1 1
1 1
CONSTRUCTION RW
PW ENGINEERING
1 FIRE DEPT
1 PLANNING DEPT
BUILDING
1 1 1
1 1 1
1 1
1 1
CITY OF PORT ANGELES
PUBLIC WORKS UTILITIES DIVISION
321 EAST 5TH STREET PORT ANGELES, WA 98362
Page 2
Application Number 06 00000280 Date 5/09/06
Application pin number 974240
Permit Fee Total 825 00 825 00 00 00
Plan Check Total 00 00 00 00
Other Fee Total 2074 50 2074 50 00 00
Grand Total 2899 50 2899 50 00 00
Separate Permits are required for electrical work, SEPA, Shoreline, ESA, utilities, private and public improvements. This permit becomes
null and void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned
for a period of 180 days after the work as commenced, or if required inspections have not been requested within 180 days from the last
inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of
laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not
presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construction.
Signature of Contractor or Authorized Agent Date Signature of-Owner (if owner is builder) Date
T•\Policies \l 102.15R {1/05]
CALL 417 -4807 FOR UTILITY INSPECTIONS. PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAWFUL TO COVER,
INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT IN A CONSPICUOUS LOCATION.
PW UTILITIES (Engineering Division)
WATERLINE METER
SEWER CONNECTION
SANITARY
STORM
SITE DRAINAGE
SITE EROSION CONTROL
PARKING
SIDEWALK
CURB GUTTER
DRIVEWAY APPROACH
BACK FLOW DEVICE
T•\Policies \1102.15R (1 /05)
RESIDENTIAL
CONSTRUCTION RW PW/ 417 4807
ENGINEERING
FIRE 417 -4653 1
PLANNING DEPT 417-4750
BUILDING 417 -4815
PERMIT INSPECTION RECORD
KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE
INSPECTION TYPE DATE ACCEPTED
YES 1 NO
1 .1
1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1
CONSTRUCTION RW
PW ENGINEERING
1 FIRE DEPT 1
1 PLANNING DEPT 1
BUILDING
COMMENTS
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE
DATE YES NO COMMERCIAL DATE ACCEPTED
YES 1 NO
1 1
1 1
1 1
1 1
VP BUILDINGS
VARCO PRUDEN
`t'PFD Nn T�
*•O t( '-SS I3 L110-f3E
KLooNYT U tM
2 A 1 43C F
,P• Z f.L E- I.rT Ct EXIT
CITY OF PORT 'ANGELES Construction Plans
The Issuance of this permit based upon these plans, specifi-
cations and other data shall not prevent the building official
from thereafter requiring the correction of errors in said
plans, specifications and other data, or from preventing
building operations being carried on thereunder when in
violation of ail codes and ordinances of this jurisdiction.
m r I 'rr�r
\l'
Approval Date
(0 T141.1_ r CEONZ t'P- 6 CAW
scAct -E H-ous€
Ric
LSE R
DRAWING INDEX
DRAWING TITLE
Cover Sheet
Notes
Anchor Bolt Plan
Primary Structural
Secondary Structural
Covering
Special Drawings
Standard Erection Details
MRD'S
THE VP ENGINEER S SEAL APPLIES ONLY TO THE WORK PRODUCT OF VP
AND DESIGN AND PERFORMANCE REQUIREMENTS SPECIFIED BY VP THE
VP ENGINEER S SEAL DOES NOT APPLY TO THE PERFORMANCE OR DESIGN
OF ANY OTHER PRODUCT OR COMPONENT FURNISHED BY VP EXCEPT TO
ANY DESIGN OR PERFORMANCE REQUIREMENTS SPECIFIED BY VP
PAGES
1
2
3
4 -7
8 -12
13 -17
18 -21
22 24-
VP Buildings, Inc. 3200 Pla
TYPE
PERMIT DRWG'S FOR APPROVAL
DRAWING RELEASE HISTORY
DATE
11/11/05
e Memphis TN 38125 pc C" l7 I 1 f oS
DESCRIPTION
FOR APPROVAL NOT FOR CONSTRUCTION
RLE
PLANS APPROVED BY
y f E DEPT
1 r 'i_k l.rL:..E 1 121EP
DATE
GPI O lr1
P-C! FO Oro 03
THI DRAWING NC DING THE FOR REO
REMAIN THE ROP RTY OF VP LOIN
R IS PROVIDED SOLELY FOR ER CTING THE LDING
DESCRIBED IN THE APPLICABLE RCHASE ER AND
SHALL NOT BE ODIFIED. DOR FOR
ANY OTHER PURPOSE WITHOUT IOR WRITTEN
PROVAL OF VP B ILDINGS
NERAL CONTRACTOR ND/OR RECTOR I5 5
RESPON I LE FOR ACCU TE. GOOD DUALITY WORKMA
ERECTING THIS IN CON RMANCE WITH
AWI DETA L5 ER NCED IN HIS DRAWI
LAPP CABLE VP LDING5 EREC ON G IDES
AND NDU ARDS PERT PRO
ER CTK)N ORREC SE OF TEMPORARY
B NG
MATERIALS
3 PLATE WELDED SECTIONS
COLD FORMED LIGHT GAGE SHAPES
BRACE RODS
HOT ROLLED MILL SHAPES
HOLLOW STRUCTURAL SECTION (HSS)
CLADDING
A325 BOLT TIGHTENING REQUIREMENTS
GENERAL NOTES
ASTM DESIGNATION
A529, A572, A1011 SS
A1011 SS
A572
A36, A572, A529, A992
A500
A653, A792
IT IS THE RESPONSIBILITY OF THE ERECTOR TO INSURE PROPER BOLT TIGHTNESS IN ACCORDANCE WITH APPROPRIATE
REGULATIONS. THE FOLLOWING CRITERIA IS IN COMPLIANCE WITH THE LATEST SPECIFICATIONS, HOWEVER THE ERECTOR
IS RESPONSIBLE TO VERIFY LOCAL AUTHORITY REQUIREMENTS.
ALL CONNECTIONS MADE WITH A325 BOLTS MAY BE TIGHTENED TO THE "SNUG TIGHT' CONDITION AS PERMITTED BY THE
SPECIFICATION FOR STRUCTURAL JOINTS USING A325 OR A490 BOLTS (2000 ED UNLESS INDICATED AS
PRE TENSIONED' ELSEWHERE IN THESE DRAWINGS, OR AS INDICATED BELOW
PRE TENSION BOLTS ON PRIMARY FRAMING, BOLTED BRACING, AND STRUT CONNECTIONS IF LOCATED IN SEISMIC
PERFORMANCE DESIGN CATEGORY D E OR F (ZONE 3 OR 4). SEE CODES AND LOADS NOTES BELOW FOR
SEISMIC DESIGN CATEGORY
PRE TENSION BOLTS ON PRIMARY FRAMING, BOLTED BRACING, STRUTS AND CRANE RUNWAY CONNECTIONS IF
BUILDING SUPPORTS A CRANE WITH A CAPACITY GREATER THAN 5 TONS.
CONNECTIONS THAT SUPPORT RUNNING MACHINERY AND OTHER SOURCES OF IMPACT OR STRESS REVERSAL MUST
BE PRE TENSIONED
ALL SLIP CRITICAL CONNECTIONS AS INDICATED IN THESE DRAWINGS WITH -SC DESIGNATION MUST BE
PRE TENSIONED. SC TYPE CONNECTIONS MUST BE FREE OF PAINT OIL OR OTHER MATERIALS THAT REDUCE THE
FRICTION AT CONTACT SURFACES.
CODES AND LOADS
ALL A490 BOLTS MUST BE PRE TENSIONED WITH WASHERS UNDER TURNED ELEMENT
SECONDARY MEMBERS AND FLANGE BRACE CONNECTIONS ARE ALWAYS 'SNUG TIGHTENED" EVEN IF ABOVE CONDITIONS
EXIST UNLESS SPECIFICALLY NOTED OTHERWISE ON DETAILS.
WASHERS ARE NOT REQUIRED FOR "SNUG- TIGHT' CONNECTIONS PRE TENSIONED CONNECTIONS TIGHTENED USING THE
TURN -OF THE -NUT METHOD DO NOT REQUIRE WASHERS.
WHEN MULTIPLE BUILDINGS ARE INVOLVED, SPECIFIC LOAD FACTORS FOR DIFFERING OCCUPANCIES, BUILDING DIMENSIONS,
HEIGHTS, FRAMING SYSTEMS, ROOF SLOPES, ETC. MAY RESULT IN DIFFERENT LOAD APPLICATION FACTORS THAN
INDICATED BELOW SEE CALCULATIONS FOR FURTHER DETAILS.
Building Code: 2003 International Building Code
Scale House: Building Use:Standard Occupancy Structure, Collateral Gravity' 7.00 psf (Not Including bldg wt)
LIVE LOADS AND RAINFALL
Live Load 20.00 psf (Reducible)
Rainfall: 4.00 inches per hour
SNOW LOAD
Ground Snow: 42.61 psf, Flat Roof Snow: 26.84 psf
Snow Exposure Category (Factor): 2 Partially Exposed (0.90)
Snow Importance: 1.000 Thermal Category (Factor): Heated (1.00)
WIND LOAD
Wind Speed: 100.00 mph, Wind Exposure: D
Basic Wind Pressure: 22.42 psf
Wind Importance Factor 1.000, Ft= Topographic Factor 1.0000
Wind Enclosure: Enclosed, 0.180
Note: If the building is designed as ENCLOSED all windows, doors, skylights
and other covered openings must be designed for the specified above wind loads
EARTHQUAKE DESIGN DATA
Lateral Force Resisting Systems using Equivalent Force Procedure
Mapped Spectral Response Ss:124.10 %g, S1:50.90 %g
Seismic Hazard Use Group: Group 1
Seismic Performance Design Category* D (See Bolt Tightening Note Above)
Seismic Snow Load: 0.00 psf
Seismic Importance: 1.000
Soil Profile Type: Very dense soil and soft rock (C, 3)
Design Spectral Response Sds: 0.8273, Sd1 0.4411
Ordinary Steel Moment Frames
Frame Redundancy Factor 1.0000
Framing R -Factor 3.5000, Frame Seismic Factor (Cs): 0.2364, Design Base Shear 0.2364 W
Ordinary Steel Concentric Braced Frames
Brace Redundancy Factor 1.0000
Bracing R -Factor 3.5000, Brace Seismic Factor (Cs): 0.2364, Design Base Shear 0.2364 W
VP BUILDINGS, INC.
AISC CATG. MB CERTIFIED
11/9/2005 8:52:51
COVER SHEET
BUILDER
CHG Building Systems, Inc.
CUSTOMER
ET Environmental
LOCATION Port Angeles, Washington
PROJECT Port Angeles Transfer Station
BUILDERS POY 15226
FILENAME CA0501694 -010E1 vpc
GRADE 50
GRADE 55
GRADE 65
GRADE 36 KSI OR GRADE 50
GRADE B
GRADE 50 CLASS 2 OR GRADE 80
THW5 WET SIGNATURE APPLIES TO
ALL SHEETS AS LISTED
ON DRAWING INDEX
trtrzo
L EXPIRES 07 18-
VP BUILDINGS
VARCOP OEN
VPC VER ION 5.3b
JOBC
CA0501694 -01
DATE
10/4/2005
DRAWN /CHECK
MDS
PAGE
1
BUILDER/CONTRACTOR RESPONSIBILITIES
VP Buildings follows the guidelines as outlined in the AISC and MBMA Codes of Standard Practice. VP
Buildings standard product specifications, design, fabrication, quality criteria shall govem all work unless
stipulated otherwise in the contract documents. In case of discrepancies between VP Buildings structural plans
and plans for other trades, VP Building structural plans shall govem.
It is the responsibility of the Builder to obtain approvals and pemlits from all goveming agencies and
jurisdictions as required Approval of VP Building drawings constitutes the builders acceptance of VP
interpretation of the contract purchase order Unless specific design criteria conceming interface design and
details are fumished as part of the contract, VP Buildings design assumptions shall govern.
VP engineers are not Project Engineers or Engineer of Record for the overall project. VP engineering supply
sealed engineering design data and drawings for VP supplied material as part of the overall project for use by
others to obtain permits, approvals, and coordinate with other trades. The Builder or AIE firm are responsible
for the overall project coordination, including coordination with appropriate inspection and testing agencies. All
interface and/or compatibility of any materials not fumished by VP are to be considered and coordinated by
the builder or NE firm.
CONSTRUCTION ERECTION RESPONSIBILITY
The Builder is responsible for construction in strict accordance with VP Buildings TOR CONSTRUCTION'
drawings and all applicable product installation guides. VP is not responsible for work done from any other VP
drawings that are not marked FOR CONSTRUCTION" nor any drawings prepared by others. The Builder is
responsible for accurate setting of anchor bolts 1/8" accuracy), erection of steel, and required alignment
such that components are straight and plumb per MBMA Code of Standard Practice. Out of straightness for
any member shall not exceed 1/300.
The building erector shall be properly licensed and experienced in erecting metal building systems. The Builder
is responsible for having knowledge of, and shall comply with, all OSHA requirements and all other goveming
site safety criteria. The builder is responsible for designing, supplying, locating and installing temporary
supports and bracing during erection of the building. VP bracing is designed for code required loads after
building completion and shall not be considered as adequate erection bracing. Se VP Builder Memo #BM -006.
EXISTING STRUCTURES
VP must be advised of any existing structure that is within 20 ft. of VP's building. Loadings of both buildings
may be affected when adjacent buildings are within this distance. VP cannot be responsible for the design or
loading of existing buildings.
BRACING
Tension brace rods work in pairs to balance forces caused by initial tensioning Care must be taken while
tightening brace rods so as not to cause accidental or misalignment of components. All rods must be
installed loose and then tightened. Rods should not exhibit excessive sag. For long or heavy rods, or angles
it may be necessary to support the rod at mid -bay by suspending it from a secondary member
Bracing for seismic or wind loading of objects or equipment that are not a part of the VP structure must be
designed by a qualified professional to deliver lateral loads to primary frames and rod bracing struts.
Equipment bracing and suspension connections must not impose torsion or minor axis loads, or cause local
distortion in any VP components. VP accepts no responsibility for design or installation of bracing systems
not furnished by VP
FIELD WELDING
All field welding shall be done at the direction of a design professional, and done in accordance with governing
requirements (AWS in USA, CWB in Canada) by welders qualified to perform the welding as directed by the
applicable welding procedure specification (WPS). A WPS shall be prepared by the contractor for each welding
variation specified. Unless otherwise approved, use E7Oksi yield, low hydrogen electrodes The contractor shall
provide for any special welding inspection as required by code.
DELIVERIES
It is the responsibility of the builder to have adequate equipment available at the job site to unload trucks in
a safe and timely manner. The Builder will be responsible for at retention charges from carriers as a result
of job site unloading delays.
Per VP Builder Memo #BM -001 claims for damage or losses MUST be noted on the Bill -of- Lading or delivery
receipt and filed against the carrier by the consignee as per VPs Terns of Sales (F.O.B. Plant) under the
Uniforrn Commercial Code. It is critical that damages or loss be noted on the Bill -of- Lading or you have
little recourse with the carrier. Immediately upon delivery of material, material quantities are verified by the
Builder against quantities billed on the shipping document. Neither the Manufacturer nor the carrier is
responsible for material shortages against quantities billed on the shipping document if such shortages are not
noted on the shipping documents upon delivery of material and acknowledged by the carriers agent For
materials concealed in bundles, boxes, or crates, shortages must be reported immediately upon unpacking.
Should products get wet, bundled and crated materials must be unpacked and unbundled immediately to
provide drainage of trapped moisture.
SEALANTS
Sealants shall be applied in strict accordance with VP details or weather tightness will be compromised.
Sealant must be applied in temperatures and weather conditions consistent with labeling.
Butyl Sealants Service Temperature Range (Degrees): Min -40F -40C); Max 200F (104C)
Tape sealants Service Temperature Range (Degrees): Min -60F -50C); Max 212F (100C)
INDEPENDENT MF77ANINES
Independent mezzanines must be designed by a professional engineer The engineer must ensure that proper
isolation from the VP building has been provided to avoid structural damage due to differential movements, or
inadvertently apply loads to the VP structure. VP accepts no responsibility for the design of the independent
mezzanine
FIRE CODE COMPLIANCE
It is the responsibility of the project design professional and builder to comply with local fire code regulations
including consideration of, but not limited to, building use and occupancy, all building construction materials,
separation requirements, egress requirements, fire protection systems, etc Builder shall advise VP of any
special requirements to be fumished by VP
SSR roof fire tested to ASTM E108 -93 -Class A rating.
VP steel roof systems are defined by IBC as Fire Class A roof assemblies (Sec 1505.2).
VP SSR steel roof systems are available for FM Class 1 fire rating
UL 263 approved fire rated assemblies listed as Design No. P265, P268 and P516.
FIELD MODIFICATIONS
Modifications to this building from details and instructions contained on these drawings must be approved in
writing by VP Building engineers, or other licensed structural engineer This includes, but is not limited to,
removal of roof or wall cladding, removing or moving any flange braces or rod braces, cutting of openings for
doors, windows or RTU's, correction of fabrication errors, etc. The owner shall not impose loads to this
structure beyond what is specified for this building in the contract documents. VP Buildings Inc accepts no
responsibility for the consequences of any unauthorized additions, alterations, or added loads to this structure.
Per VP Builder Memo #BM -001, if the builder intends to invoice VP Buildings for modifications in excess of
51000, the builder must notify VP Buildings immediately and obtain a Work Authorization from VP Buildings
prior to proceeding. All final claims must be submitted to VP Buildings with all supporting documentation
within 30 days of the building completion. Claims submitted without work authorizations, or after 30 days will
not be accepted. Correction of minor misfits, shimming and plumbing, moderate amount of reaming, drilling,
chipping cutting and minor welding are considered by Code of Standard Practice to be part of erection are
not subject to claim reimbursement.
CONCRETE/MASONRY /CONVENTIONAL STUD WALLS
The engineer responsible for the design of the wall system is responsible for coordinating with, or specifying to
VP Buildings, any wall to steel compatibility issues such as drift and deflection compatibility, special base
details, and wall to VP steel connections All fasteners, sealant and counter flashing of wall systems are to
be provided by contractor
PANELS
Oil canning is an inherent characteristic of cold formed steel panels. It is the result of several factors that
include induced stresses in the raw material delivered to VP fabrication methods, installation procedures, and
post installation thermal forces. Thru fastened panels will exhibit some dimpling when installed, especially when
insulation is installed between panels and secondary supports. Dimpling can be minimized by careful
installation, taking care not to over drive fasteners.
Roof rumble is a phenomenon that is caused by wind gusts lifting up on the roof panels and then springing
back into place. All panels experience this action to some degree, especially with concealed clip panels such
as SSR and SLR. Roof rumble noise may be minimized by providing a layer of blanket Insulation between
the panels and any hard support surface such as steel secondary members, substrates such as plywood, steel
decking, or rigid board insulation A minimum of 3 inch thick blanket is recommended over steel secondary
members, or 2 inch over substrates.
Oil canning, dimpling, and roof rumble do not affect the structural Integrity or weather tightness of the panels
and is not grounds for rejection of panels.
The SSR/SLR joint detail is designed with an interlocking feature for ease of installation. However it is
imperative that installed SSR/SLR panels be secured to the secondary structural members and properly seamed
prior to departure from the job site each day.
SKYLIGHTS
VP's Tuflites and VPs domed skylight have been tested to support a 300 Ib. load over a 1 sq. ft. area, as
well as uniform gravity and uplift load test. Local building departments may require added fall restraint due
to conditions that may affect the skylight structural integrity It is the responsibility of the builder to
determine and provide any added fall restraint under the skylight as may be required by your building
department.
RAIN WATER RUNOFF
Drainage systems must be designed by the project professional to comply with code requirements. VP is
not responsible for drainage designs, overflow scuppers, down piping, etc. The project professional and
contractor are responsible to ensure that primary drains and overflow devices such as scuppers and auxiliary
drains are provided as required for the required rain intensity at the building perimeter and at valley conditions
to prevent ponding.
STEEL SHOP COAT
The purpose of VP's shop coatis to provide protection for the steel members during transportation, during
temporary job site storage and during erection. Standard shop formulation is not designed to perform as a
finish coat when exposed to environmental conditions. Members shall be kept free of the ground and properly
drained during job site storage. It is the Builders responsibility to ensure that if a finish coat is being applied
over VP shop coat that the painting contractor verifies compatibility between his finish coat and VPs shop
coat See VP Builder Memo #BM-001 #BM-002.
THE VP ENGINEER 5 SEAL APPLIES
ONLY TO THE WORK PRODUCT OF
VP AND DESIGN AND PERFORMANCE
REQUIREMENTS SPECIFIED BY VP
THE VP ENGINEER 5 SEAL DOES
NOT APPLY TO THE PERFORMANCE
OR DESIGN OF ANY OTHER PRODUCT
OR COMPONENT FURNISHED BY VP
EXCEPT TO ANY DESIGN OR PER
FORMANCE REQUIREMENTS
SPECIFIED BY VP
THIS DRAWING. INCLUDING THE INFORMATION HEREON
REMAINS THE PROPERTY OF VP BUILDINGS.
R IS PROVIDED SOLELY FOR ERECTING THE LDING
ESCRIBED IN THE APPLICABLE PURCHASE ORDER AND
SHALL NOT BE MODIFIED. REPRODUCED OR US FOR
ANY OTHER PURPOSE WITHOUT PRIOR WRRTEN
APPROVAL OF V BU LDINGS.
NERAL CONTRACTOR ND/OR EREC OR OLEL
SPONSIBLE FOR ACCURAT GOOD QUALM WO KMANS
ECTING THIS UILDING CONFORMANCE WRH TN
DRAWING DETAILS REFERENCED IN THIS DRAWI
ALL APPLICABLE VP ERECTION GUIDES
TANDARDS PERTAIN NG TO PROPER
ER ING THE CORRECT USE OF TEMPORARY
BRAG
VP BUILDINGS CERTIFICATIONS
AISC
LAS
CSA -A660
CWB
Los
Angeles, CA
Houston,
TX
Riverside,
CA
Clark Co.
NV
San
Bernardino
Co, CA
Aiaoama
MB Cert.
FA -377
REVI
DATE
PLANT SPECIFIC CERTIFICATIONS
California
MB Cert.
FA -240
VPBULO
Div. 1
Div 1
Type 1 Fab
#SP02 -0028
Fab ID#241
Fab ID# 121
VP Buildings, Inc.
3200 Players Club Circle Memphis TN 38125
Missoun 1 No. Carolina
MB Cert MB Cert.
FA -388 I FA -376
NTS
11/9/2005 11'10:23
DES IP ION
Wisconsin
MB Cert.
FA -378
VPBUIO
Div 1
Div 1
ICC Evaluation Reports
SSR Roof System #ER -5621
Panel Rib Roof and Wall #ER -4879
Vee Rib Wall #ER -4879
State of Florida Product Approval (Listed as VP Buildings)
Dade Co. Product Certification
SSR Roof NOA#03- 0206.13; Panel Rib Roof NOA#02 -0123.08; Panel Rib Wall NOA#02- 04187.01;
Vee Rib Wall NOA#01- 1128.05
Underwnters Laboratory Approvals
SSR Roof- UL#TGKX-113; SSR Composite Roof Class 90- UL#TGKX -113A, SSR Roof w /Super Block
Class 90- UL#TGKX -328;
Panel Rib Roof UL Class 60- UL#TGKX -60; Panel Rib Roof UL Class 90- UL#TGKX -64;
VP SLR/AEP SL Roof Class 90- UL#TGIO( -60
Factory Mutual Approved Assemblies
SSR Roof Systems are approved in various type applications and listed in FM Approval Guide.
24 Ga SSR (0.0227" Nominal), is available in Class 1-60, 1 -75, 1 -90. 22Ga SSR (0.0277"
Nominal), is available in Class 1 -75, 1 -90- 1 -120.
Mexico
MB Cert.
Approved
ERECTION NOTES
BUILDER
CHG Building Systems, Inc.
ICUSTOMER Environmental
ILOUno5 Port Angeles, Washington
IPReJEGT Port Angeles Transfer Station
(BUILDER'S POR 15226
FILENAME: CA0501694 -01 OE 1.vpc
EXPIRES
FOR APPROVAL NOT FOR CONSTRUCTION
VPC VERSIO 5.3b
Da
CA0501694 -01
DATE
10/4/2005
VP BUILDINGS NFHECK
505551.555 MDS
PAGE 2
1
305mm
12
212" I I L217
B1mn, -1 SCmm
F
2 3 -4 1/4
1 1 -9"
Dimension Key
D1 (4) Dia A36 A Bolts
Plate W 9 L =10"
Elevation =100 -0
D2 (4) Dia A36 A Bolts
Plate W =9 L =10"
Elevation =100 -0
lk
21/2" 1. L212"
64mm 'I54mm
F
1 CONCRETE, GROUT ANCHOR BOLTS, AND ANY OTHER EMBEDDED ITEMS ARE
TO BE FURNISHED BY OTHERS
2. ANCHOR BOLT DIAMETERS WERE DETERMINED BY ALLOWABLE SHEAR AND TENSION
PER AISC SPECIFICATIONS (FY 36 KSI). ANCHOR BOLT LENGTH, EFFECTS
OF EMBEDDED ANCHOR BOLT EDGE DIMENSIONS AND METHOD OF TRANSFERRING
FORCES FROM ANCHOR BOLTS TO FOOTINGS ARE TO BE DETERMINED BY OTHERS.
3. DESIGN LOADS AND REACTIONS ARE FURNISHED IN THE REACTIONS REPORT
4. FOUNDATION MUST BE LEVEL, SQUARE AND SMOOTH. ANCHOR BOLTS MUST BE
ACCIJRATFLY PLACED AS SHOWN ON THIS I)RAWIN(; OR STFFI Wii 1 NOT FIT
I
P1
r 2 1/2" (64mm)
PROJECTION (U.O.N.)
BOTTOM OF COLUMN
S BASE PLATE ELEV
TYPICAL ANCHOR
BOLT PROJECTION
THE VP ENGINEER 5 SEAL APPLIES
ONLY TO THE WORK PRODUCT OF
VP AND DESIGN AND PERFORMANCE
REQUIREMENTS SPECIFIED BY VP
THE VP ENGINEER 5 SEAL DOES
NOT APPLY TO THE PERFORMANCE
OR DESIGN OF ANY OTHER PRODUCT
OR COMPONENT FURNISHED BY VP
EXCEPT TO ANY DESIGN OR PER-
FORMANCE REQUIREMENTS
SPECIFIED BY VP
17 -8"
1 1
1 1/4"
32mm
1/2" (13mm) DIAMETER
CONCRETE ANCHORS
(NOT BY VP)
OPENING WIDTH I 11A"
IIII 111 32mm
NOTE: 1" (25mm) PROJECTION ABOVE
BOTTOM OF JAMB CLIP
FRAMED OPENING DETAIL
E
E
D2
D21
I.
34 -11 1/4
ANCHOR BOLT PLAN
VARIES 1 I i
BOTTOM OF
COLUMN
1
BASE PLATE
STD 12" (13mm)
FLUSH 0" (Omm)
TYPICAL COLUMN
BASE PLATE DETAIL
Finished Floor Elevation 100' -0" (Unless Noted Otherwise)
THIS DRAWING INCLUDING THE INFORMATION HEREON
REMAINS THE OPERTY OF VP BUILDINGS.
R IS PROVIDED Y FOR ERECTING THE BUILDIN
DESCRIBED N E APPLICABLE PURCHASE ORDER AND
SHALL NO ODIFIED, REPRODUCED OR U5 FOR
ANY OTHE RPOSE WITHOUT PRIOR WRITTEN
PPROVAL OF P BUILDINGS.
THE GENERAL CONTRACTOR AND/OR ERECTOR IS 5
5PON5 OR URATE, GOOD QUALITY WORKMAN
ERECTING THIS DING N CON RMANCE WITH THI
DRAWING, DETAILS FERENCED IN DRAWI
LL APPLICABLE VP ERECTIO GUIDE
NDI U STANDARD PERTAIN TO PROPER
CTIO UDING THE CORRECT SE OF TEMPORARY
RAC(
17 -3 1/4
D 1t
VP Buildings, Inc.
3200 Players Club Circle Memphis TN 38125
R VI
ATE
11/9/2005
!PTO
8:52:52
0
r
ANCHOR BOLT PLAN
(BUILDER CHG Building Systems, Inc.
1USTOMER ET Environmental
(LOCATION Port Angeles, Washington
(PROJECT Port Angeles Transfer Station
(BUILDER'S POY 15226
FILENAME CA0501694 -01OE1 vpc
-33
ISTER�
te' L VAL El
[EXPIRES 07 18 �b
FOR APPROVAL NOT FOR CONSTRUCTION
VP BUILDINGS
VPC VERSION: 5.3b
JOB 9
CA0501694 -01
DATE
10/4/2005
DRAWN/CHECK
MDS
PAGE 3
1 1 -0
Dimension Key
1 USE 1/2 X 1 1/2 A325 SNUG TIGHTENED BOLTS FOR PURLIN TO
FRAME, GIRT TO FRAME, AND GIRT TO CLIP CONNECTIONS
UNLESS NOTED OTHERWISE.
2. SLOT REINFORCEMENT PLATES NEED NOT BE LOCATED ON THE SAME
SIDE OF THE WEB AS THE HILLSIDE WASHER.
1
CX002
CX001
16 -8
THE VP ENGINEER S SEAL APPLIES
ONLY TO THE WORK PRODUCT OF
VP AND DESIGN AND PERFORMANCE
REQUIREMENTS SPECIFIED BY VP
THE VP ENGINEER S SEAL DOES
NOT APPLY TO THE PERFORMANCE
OR DESIGN OF ANY OTHER PRODUCT
OR COMPONENT FURNISHED BY VP
EXCEPT TO ANY DESIGN OR PER-
FORMANCE REQUIREMENTS
SPECIFIED BY VP
1
34 -11 1/4
CX004
CX003
PRIMARY AND ROOF BRACING PLAN
VP Ref: Shane Name Scale House
THIS DRAWING, INCLUDING THE INFORMATION HEREON
REMAINS THE PROPERTY OF VP LDINGS
R IS PROVIDED 5OL FOR ERECTING THE BUILDIN
DESCRIBED IN THE APPLICABLE CHASE ORDER AND
SHALL OT BE MOD ED, REPRO UCED OR USED FOR
ANY 0 HER PURPOSE WrrHOUT PRIOR WRITTEN
APPROVAL OF VP
THE G NERAL CONTRACTOR AND,OR I5 SOLELY
RESPONSIBLE FOR ACCURATE, GOODOUALTfY WORKMAN
ERECTING THIS N CONFORM CE WITH THIS
DRAWING, DETA NCED N TIII AWI
ALL APPLICABLE ON S
ND INDUSTRY STANDARDS PERTAIN TOP OPER
RECTION NCLUO THE CORR F TEMPORARY
RACING.
16 -3 1/4
VP Buildings, Inc.
3200 Players Club Circle Memphis TN 38125
R VI DATE
11/9/2005
DESCRIPTIO
O
X
CX006
CX005
BUILDER
CHG Building Systems, Inc.
I CUSTOMERET Environmental
'LOCATION Port Angeles, Washington
'PROJECT Port Angeles Transfer Station
'BUILDER'S PC' 15226
8:52:53 FILENAME CA0501694 -010E1 vpc
1 EXPIRES 07 18- oS
FOR APPROVAL NOT FOR CONSTRUCTION
PRIMARY AND ROOF BRACING PLAN
CA0501694 -01
DATE
10/4/2005
DRAWN/CHECK
MDS
P 5 4
Frame
Part
CX001
RBX001
RBX002
CX002
7 9 -6 15/16"
6 3 1/4"
5 2 2 -4"
4 1 -7 7/16"
3 1 -6"
2 2 3 -6"
1 8 1/2"
n Dimension Key
Member Schedule
Mem Width Thick
1 5 1345
2 5 1345
3 5" 1345
4 5" 1345
Webthk
1345
1345
1345
1345
1 USE 1/2 X 1 1/2 A325 SNUG TIGHTENED BOLTS FOR PURLIN TO
FRAME, GIRT TO FRAME, AND GIRT TO CLIP CONNECTIONS
UNLESS NOTED OTHERWISE.
2. SLOT REINFORCEMENT PLATES NEED NOT BE LOCATED ON THE SAME
SIDE OF THE WEB AS THE HILLSIDE WASHER.
Depthl
9"
10 1/2"
9 1/16
9"
Depth2 Approx Lgth
9 8 -0 3/16
9 1/16 5 -2 5/8
10 1/2" 5 -2 5/8"
9" 8 -0 3/16"
CO rb
GGC10
FB2050
THE VP ENGINEER S SEAL APPLIES
ONLY TO THE WORK PRODUCT OF
VP AND DESIGN AND PERFORMANCE
REQUIREMENTS SPECIFIED BY VP
THE VP ENGINEER 5 SEAL DOES
NOT APPLY TO THE PERFORMANCE
OR DESIGN OF ANY OTHER PRODUCT
OR COMPONENT FURNISHED BY VP
EXCEPT TO ANY DESIGN OR PER-
FORMANCE REQUIREMENTS
SPECIFIED BY VP
,6 -6 11/
PI
n
0
0
0
r
0A325 Bolt Connection Plate Schedule
Id Qty Bolt
Dia
A 4 3/4"
B 4 3/4
GC10
Bolt Plate
Length Thick
2 1/4" 1/2
2 3/8"
J.
Rows
Out
1
1
12 -11 1/4"
Rows
In
1
1
IL
GC10
FRAME CROSS SECTION AT FRAME LINE(S) 1
VP Ref: Shaoe Name Scale House Wall 4, Frame 1
THIS DRAWING, INCLUDING THE INFORMATION HEREON
REMAIN HE PROPERTY OF VP BUILDINGS.
R IS ROVIDED SOLEL FOR ERECTING THE BUILD'
DESCR ED IN HE APPLICABLE PURCHASE ORDE AND
SHALL NOT BE ODIF1ED. REPRODUCED OR USE FOR
ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN
P ROVAL OF VP BUILDINGS.
Tension Washer
Bolt
Yes Yes
Yes Yes
2 0 00
THE NERAL CONTRACT R AND EREC I5 LELY
RESPON IBLE FOR ACCURATE. GOOD QUALITY WORKMAN
ER CTING THIS UILDIN N CONFOR MAN E WITH THIS
DRAWING. DETAILS R FEREN ED IN THIS DRAWIN
LL APPLICABLE VP ERECTION UIDES
ND S RY N ARDS TAINI TO PROPS
RECTOR G THE CORRECT 5E OF TEMPORARY
BRAG
N
0
0
U
12-
1
fi
GC104
FB2050
VP Buildings, Inc.
3200 Players Club Circle Memphis TN 38125
REV' DATE
11/9/2005
Frame Clearances
Horiz Clearance between members 1(CX001) and 4(CX002) 10 -0 1/4
Vert Clearance at member 1(CX001) 7 -1 5/8"
Vert Clearance at member 4(CX002) 7 -1 5/8"
Finished Floor Elevation 100 -0" (Unless Noted Otherwise)
I
I I
I I
NTS
ED
ESCRIPTION
6 EXPIRES 07 18- O(=
FOR APPROVAL NOT FOR CONSTRUCTION
FRAME CROSS SECTION AT FRAME LINE(S) 1
BUILDER
CHG Building Systems, Inc.
ICUSTDMERET Environmental
'LOCATION Port Angeles, Washington
'PROJECT Port Angeles Transfer Station
'BUILDER'S PON 15226
8:52:55 FILENAME CA0501694 -01 OE1.vpc
I I LDINGS
VPC VER ION 5.3b
JOB
CA0501694-01
DATE
10/4/2005
DRAWN/CHECK
MDS
PAGE 5
O Frame
Part
CX003
RBX003
RBX003
CX004
7 9 -6 15/16
6 3 1/4"
5 2 2 -4"
4 1 -7 7/16"
3 1 -6
2 2 3 -6
1 8 1/2"
Dimension Key
Member Schedule
Mem Width Thick
1 5 1345
2 5" 1345
3 5 1345
4 5" 1345
Webthk Depthl
1345 9"
1345 10 1/2
1345 9"
1345 9"
1 USE 1/2 X 1 1/2 A325 SNUG TIGHTENED BOLTS FOR PURLIN TO
FRAME, GIRT TO FRAME, AND GIRT TO CLIP CONNECTIONS
UNLESS NOTED OTHERWISE.
2. SLOT REINFORCEMENT PLATES NEED NOT BE LOCATED ON THE SAME
SIDE OF THE WEB AS THE HILLSIDE WASHER.
Depth2
9
9"
10 1/2
9"
C)
END
Approx Lgth
8 -0 3/16"
5 -2 5/8"
5 -2 5/8
8 -0 3/16"
(2)FB2050
THE VP ENGINEER S SEAL APPLIES
ONLY TO THE WORK PRODUCT OF
VP AND DESIGN AND PERFORMANCE
REQUIREMENTS SPECIFIED BY VP
THE VP ENGINEER S SEAL DOES
NOT APPLY TO THE PERFORMANCE
OR DESIGN OF ANY OTHER PRODUCT
OR COMPONENT FURNISHED BY VP
EXCEPT TO ANY DESIGN OR PER-
FORMANCE REQUIREMENTS
SPECIFIED BY VP
—6
1
n
0
0
QA325 Bolt Connection Plate Schedule
Id Qty Bolt Bolt Plate Rows Rows Tension Washer
Dia Length Thick Out In Bolt
A 4 3/4" 2 1/4" 1/2 1 1 Yes Yes
B 4 3/4 2 3/8 1 1 Yes Yes
2
12 -11 1/4
RaX003
N
N
U
a
FRAME CROSS SECTION AT FRAME LINE(S) 2
VP Ref: Shaoe Name Scale House Wall 4, Frame 2
THIS DRAWING INCLUDING THE INFORMATION HEREON
REMAINSTH ERTY OF VP ILDINGS.
IT I5 PROVIDED SOL FOR ERECTING THE NG
DESCR BED IN THE APPLICABLE CHASE ORD R AND
SHALL NOT MODIFIED, REPROD CED OR US FOR
ANY OTHER RPOSE WITHOUT RWRITTE
APPROVAL OF VP NGS
THE NERAL CONTRA ND/OR TOR SOLEL
RESPON E ACCURAT GOOD LITY WOR M
IN ERECDN CONFORMANCE WITH THIS
DRAWIN DETAIL REN N THIS DRAWIN
ALL APP CABLE V CTION G 5
ND RDS PERT I G TO ROP
EREC CORR CT USE TEMPORARY
RACI
j-
V'
0
0
0
U
(2)FB2050
DATE
11/9/2005
Frame Clearances
Horiz Clearance between members 1(CX003) and 4(CX004) 10 -0 1/4
Vert Clearance at member 1(CX003) 7 -1 5/8"
Vert Clearance at member 4(CX004) 7 -1 5/8"
Finished Floor Elevation 100 -0" (Unless Noted Otherwise)
E
VP Buildings, Inc.
3200 Players Club Circle Memphis TN 38125
DE IPTION
FOR APPROVAL NOT FOR CONSTRUCTION
FRAME CROSS SECTION AT FRAME LINE(S) 2
BUILDER
CHG Building Systems, Inc.
(CUSTOMER ET Environmental
IILOCATION Port Angeles, Washington
IPRD'ECT Port Angeles Transfer Station
(BUILDER'S POk 15226
8:52:56 FILENAME: CA0501694 -01OE1 vpc
VP BUILDINGS I
VARNMR�x
VPC VER 5.3b
CAO5O1694-01
DATE
10/4/2005
DRAWN/CHECK
MDS
PAGE 6,
0 Frame
Part
CX005
RBX004
RBX005
CX006
7 9 -6 15/16"
6 3 1/4
5 2 2 -4
4 1 -7 7/16"
3 1 -6"
2 2 3 -6"
1 8 1/2"
Dimension Key
Member Schedule
Mem Width Thick
1 5" 1345
2 5" 1345
3 5" 1345
4 5" 1345
1 USE 1/2 X 1 1/2 A325 SNUG TIGHTENED BOLTS FOR PURLIN TO
FRAME, GIRT TO FRAME, AND GIRT TO CLIP CONNECTIONS
UNLESS NOTED OTHERWISE.
2. SLOT REINFORCEMENT PLATES NEED NOT BE LOCATED ON THE SAME
SIDE OF THE WEB AS THE HILLSIDE WASHER.
Webthk Depthl Depth2
1345 9" 9
1345 10 1/2" 9
1345 9" 10 1/2
1345 9" 9
C)
M
Approx Lgth
8 -0 3/16"
5 -2 5/8"
5 -2 5/8"
8 -0 3/16
FB2050
THE VP ENGINEER 5 SEAL APPLIES
ONLY TO THE WORK PRODUCT OF
VP AND DESIGN AND PERFORMANCE
REQUIREMENTS SPECIFIED BY VP
THE VP ENGINEER 5 SEAL DOES
NOT APPLY TO THE PERFORMANCE
OR DESIGN OF ANY OTHER PRODUCT
OR COMPONENT FURNISHED BY VP
EXCEPT TO ANY DESIGN OR PER-
FORMANCE REQUIREMENTS
SPECIFIED BY VP
1
n
0
cn
OA325 Bolt Connection Plate Schedule
Id Qty Bolt Bolt Plate Rows Rows Tension Washer
Dia Length Thick Out In Bolt
A 4 3/4" 2 1/4 1/2" 1 1 Yes Yes
B 4 3/4" 2 3/8 1 1 Yes Yes
12 -11 1/4
11/16
2 0 00
—L
FRAME CROSS SECTION AT FRAME LINE(S) 3
VP Ref: Shane Name Scale House Wall 4, Frame 3
THIS DRAWING INCLUDING THE INFORMATION HEREON,
EMAINS THE ROPERTY OF VP ILDINGS.
R ROVIDED SOLELY FOR ERECTING THE BUJ
SCRIBE N THE APPLICABLE P HASE ORD R AND
SHALL NOT BE MODIFIED, REPRODUCED OR US FOR
ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN
APPROV L OF VP BU LDINGS
THE GENERAL CONTRACTOR AND/OR ERECTOR S SOLELY
SPONSIBLE FO ACCURATE, GOOD OUALITY WORKMANS
ERECT NGTHI LDING NCONFORM CE WITH THIS
RAINING, DETA REFEREN D NTHI DRAWIN
LL APPLICABLE PERECTIO GUIDES
ND US Y NDARDS PERT N NG T PROPER
RECTIO GTHE CO OFTEMPOR
A
12
1
FB2050
IREVI
II
II
I I
DATE
11 /9/2005
Frame Clearances
Horiz Clearance between members 1(CX005) and 4(CX006) 10 -0 1/4"
Vert Clearance at member 1(CX005) 7 -1 5/8"
Vert Clearance at member 4(CX006) 7 -1 5/8"
Finished Floor Elevation 100 -0" (Unless Noted Otherwise)
NTS
m
Ei
VP Buildings, Inc.
3200 Players Club Circle Memphis TN 38125
FOR APPROVAL NOT FOR CONSTRUCTION
FRAME CROSS SECTION AT FRAME LINE(S) 3
IPTIO BUILDER
CHG Building Systems, Inc.
ICUSTOMERET Environmental
'L IEATION Port Angeles, Washington
'PROJECT Port Angeles Transfer Station
'BUILDER'S PO# 15226
8:52:58 FILENAME. CA0501694 -010E1 vpc
VP BUILDINGS
VPCVER 5 .3b
JOB
CA0501694 -01
DATE
10/4/2005
I I DRAWN/CHECK
MDS
I PAGE 7
SSR Fixed Clip Location
QSag Angle Schedule
Id Qty Mark No
1
2
See
See
32
2
SED
SED
1 1 -o
Dimension Key
Spacing
2 -4
1 -7 7/16"
SA2063(X -ing)
SA3021
BRO9A4 for installation
BRO9A5 for installation of X -ing
1 UNLESS NOTED, USE 1/2 X 1 1/2 A -325 SNUG TIGHTENED BOLTS FOR
PURLIN LAP PURLIN TO FRAME, FLANGE BRACE TO FRAME, AND FLANGE
BRACE TO PURLIN CONNECTIONS.
2. WIND FLANGE, AND PURLIN BRACING ARE AN INTEGRAL PART OF THE
ROOF STRUCTURAL SYSTEM AND SHOULD BE PROPERLY INSTALLED PRIOR
TO ERECTION OF WALL AND ROOF SHEETS. REMOVAL OR ALTERATION OF
ROOF BRACING WITHOUT PRIOR AUTHORIZATION IS PROHIBITED
THE VP ENGINEER SEAL APPLIES
ONLY TO THE WORK PRODUCT OF
VP AND DESIGN AND PERFORMANCE
REQUIREMENTS SPECIFIED BY VP
THE VP ENGINEER S SEAL DOES
NOT APPLY TO THE PERFORMANCE
OR DESIGN OF ANY OTHER PRODUCT
OR COMPONENT FURNISHED BY VP
EXCEPT TO ANY DESIGN OR PER-
FORMANCE REQUIREMENTS
SPECIFIED BY VP
02U1707417
02T1707617
02T170761F
02T170761:
02T1707617
02U1707417
16 -8"
1
34 -11 1/4
ROOF SECONDARY PLAN
VP Ref: Shaoe Name Scale House
THIS DRAWING INCLUDING THE INFORMATION HEREON.
REMAINS THE RTYO LDINGS.
IT IS PROVIDE SOLE FOR ECTING THE DUI NG
DESCRIBED IN THE APPLCABLE CHASE OBOE AND
SHALL NOT BE MODIFIED. REPRODUCED OR USED FOR
NY OTHER P POSE WITHOUT PRI R WRITTEN
PROVAL 0 BU L
THE GENERAL CONTRACTOR AND/OR ERECTOR 5 SOLELY
SPON ISLE ACLU ATE. GOOD DUALITYWORKMANSHI
ERECTING THIS BU CONFORMANCE WRH THI
DRAWING. DETAILS R EN N THIS DRAWI
LL APPLICABLE VP ER TION DES
AND INDUSTRY ND NG TO PER
ERECTION CLU GTHE T USE OF TEMPORARY
!MAGI
11/9/2005
02U1702617
02T1703017
02T1703015
02T170301.
02T1703017
02U1702617
16 -3 1/4
VP Buildings, Inc.
3200 Players Club Circle Memphis TN 38125
ESCRIPTIO
8:52:59
T
o
ROOF SECONDARY PLAN
BUILDER
I CHG Building Systems, Inc.
IGUSTOMER ET Environmental
1ILOCAnON .Port Angeles, Washington
'PROJECT Port Angeles Transfer Station
'BUILDERS PON 15226
FILENAME: CA0501694- 010E1.vpc
FOR APPROVAL NOT FOR CONSTRUCTION
VERS
VP BUILDINGS
JOB
CA0501694 -01
DATE
10/4/2005
I I DRAWN/CHECK
MDS
PAGE
°Part Mark Key
1 JBC1
2 001J0307417
3 DH0306117
4 DJC1
5 002J0308417
6 003J0302417
7 DH0406017
8 01G0304317(Flip)
9 3 -0
8 1 -4 1/4"
7 1 -o
6 8
5 1 -5 1/16
4 3 -0 15/16
3 1 -7 5/8
2 3 -6 1/4"
1 3 -11
ri Dimension Key
1 UNLESS NOTED, USE 1/2 X 1 1/2 A -325 SNUG TIGHTENED BOLTS FOR GIRT LAP
GIRT TO FRAME, FLANGE BRACE TO FRAME, FLANGE BRACE TO GIRT
JAMB AND HEADER CONNECTIONS.
2. WIND AND FLANGE BRACING ARE AN INTEGRAL PART OF THE WALL STRUCTURAL
SYSTEM AND SHOULD BE PROPERLY INSTALLED PRIOR TO ERECTION OF WALL
AND ROOF SHEETS. REMOVAL OR ALTERATION OF WALL BRACING WITHOUT
PRIOR AUTHORIZATION IS PROHIBITED
CAD
THE VP ENGINEER 0 SEAL APPLIES
ONLY TO THE WORK PRODUCT OF
VP AND DESIGN AND PERFORMANCE
REQUIREMENTS SPECIFIED BY VP
THE VP ENGINEER S SEAL DOES
NOT APPLY TO THE PERFORMANCE
OR DESIGN OF ANY OTHER PRODUCT
OR OMPONENT FURNISHED BY VP
EXCEPT TO ANY DESIGN OR PER-
FORMANCE REQUIREMENTS
SPECIFIED BY VP
u
F02
C C�� Ea,,3
01C1210617 F3 -}-p)
1
12 -11 1/4
SECONDARY ELEVATION AT 1
O Framed Opening Locations
Id Width Height Sill Ht
FO1 4 -6" 3 -0 3 -11
F02 4 -6" 3 -0" 3 -11"
FO1
T
LJ
VP Ref: Shane Name Scale House. Wall 1
THIS DRAWING INCLUDING THE INFORMATION HEREON
EMAI NS THE PROPERTY OF VP
IT ROMPED SOLELY FOR R CTING THE BUI
BED IN THE APPLICABLE CHASE RDE AND
HALL NOT BE MODIFIED, R PRO UC D OR USED
ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN
APPR VAL OF P BUILDIN
THE ERAL CONTRACTOR 80/08 ERECTOR IS SOLELY
PON BLE FOR ACCU G000 QUALITY WORKMAN
CT1NG THI BUILDIN CONFORMANCE WITHTHI
AWI DETAILS REFEREN AWI
L APP CABLE VP ERECTION
NOARDS TAIN ROPER
CTIO NCLU G T OF MPOR
ft VI
I
Frame
BL
BL
DATE
11/9/2005
To
Jamb -L
Jamb -L
VP Buildings, Inc.
3200 Players Club Circle Memphis TN 38125
NTS
Dimen
6 -9 5/8
1 -7 5/8"
EXPIRES
SECONDARY ELEVATION AT 1
IPTIO BUILDER
CHG Building Systems, Inc.
IcuSTOMERET Environmental
(LOCATION Port Angeles, Washington
e°'ECT Port Angeles Transfer Station
I BUILDER.s P 8 15226
8:53:00 FILENAME' CA0501694 -010E1 vpc
07 18- oc.�
FOR APPROVAL NOT FOR CONSTRUCTION
VP BUILDINGS
vNtCOFRuDEN
VPCVER 5.3b
JOBs
CA0501694 -01
DATE
10/4/2005
DRAWN/CHECK
MDS
PAGE 9
°Part Mark Key
1 004J0305417
2 005J0305417
3 DH0108017
8 6
7 3 -8
6 4 -0"
5 2 -9 1/4
4 3 -6
3 3 -0
2 1 -6"
1 1 -0
nDimension Key
lJ
5 —0
1 UNLESS NOTED USE 1/2 X 1 1/2 A -325 SNUG TIGHTENED BOLTS FOR GIRT LAP
GIRT TO FRAME, FLANGE BRACE TO FRAME, FLANGE BRACE TO GIRT
JAMB AND HEADER CONNECTIONS.
2. WIND AND FLANGE BRACING ARE AN INTEGRAL PART OF THE WALL STRUCTURAL
SYSTEM AND SHOULD BE PROPERLY INSTALLED PRIOR TO ERECTION OF WALL
AND ROOF SHEETS. REMOVAL OR ALTERATION OF WALL BRACING WITHOUT
PRIOR AUTHORIZATION IS PROHIBITED
F02
PPBX001
02C170261T
02C1702617(Flip)
16 -3 1/4
THE VP ENGINEER 5 SEAL APPLIES
ONLY TO THE WORK PRODUCT OF
VP AND DESIGN AND PERFORMANCE
REQUIREMENTS SPECIFIED BY VP
THE VP ENGINEER S SEAL DOES
NOT APPLY TO THE PERFORMANCE
OR DESIGN OF ANY OTHER PRODUCT
OR COMPONENT FURNISHED BY VP
EXCEPT TO ANY DESIGN OR PER-
FORMANCE REQUIREMENTS
SPECIFIED BY VP
Cam)
F02
-11 1/4
SECONDARY ELEVATION AT A
VP Ref: Shape Name Scale House, Wall 2
THIS DRAWING, INCLUDING THE INFORMATION HEREON
MAINS THE PROPERTY OF VP
7 I OVIOED SOLEL FOR ERECTING THE LDI
DESCR N HE APPLICABLE HASE ORDER AND
SHALL NO BE ODIFIED REPRODUC DOR US D FO
ANY OTHE PURPOSE WITHOUT PRIOR WRRTEN
APPRO LDINGS.
o Framed Opening Locations
Id Width Height Sill Ht Frame To Dimen
FO1 1 -8 3 -0 4 -0" 2 Jamb -L 14 -6 1
F02 3 -0" 3 -6" 3 -6 1 Jamb -L 10 -6 2100
F02 3 -0 3 -6 3 -6" 1 Jamb -L 4 -0
F03 4 -0" 3 -6" 3 -6" 2 Jamb -L 10 -0"
HE RAL CONTRACTOR AND/0 TOR S ELY
SPON E FOR ACCURATE. GOOD UALRY WORK N5H
ERE ING TH DING CONFORMANCE WITH
DRAWING, DETAIL EFERENCED DRAWI
ALL AP LICABLE V ECTION G
STRY TANDA PER GTO PROPER
CTIO G TH 0 5E OF TEMPORARY
10 -0
VP Buildings, Inc.
3200 Players Club Circle Memphis TN 38125
REV'
ATE
11/9/2005
I
I
I I
I I
32C1707417
02C1707417(Flip)
16 -8
NTS
Bracing Member Schedule
Description
3P 6" x 3/16" flg 0 1345 x
2L 3 0 x 3 0 x 0 1875 0 375
0A325 Bolt Schedule
Id Qty Bolt Diam Bolt Length Washer
1 4 3/4 1 1/2"
2 2 3/4" 2"
DESCRIPION
F03
u
0 FO1
CND CND
N EXPIRES
07 18
FOR APPROVAL NOT FOR CONSTRUCTION
SECONDARY ELEVATION AT A
BUILDER
CHG Building Systems, Inc.
IcuSTOMERET Environmental
'LOCATION Port Angeles, Washington
'PROJECT Port Angeles Transfer Station
'BUILDER'S POi 15226
8:53:01 FILENAME CA0501694 -010E1 vpc
Design Lgth
8" web 16 -3 1/4
3 -5 7/16"
VP BUILDINGS
vARO?PRLaEN
VPCV SION 5.3b
CA0501694 -01
DATE
10/4/2005
DRAWN/CHECK
MDS
PAGE 10
()Part Mark Key
1 JBC1
2 DJC1
3 006J0708117
4 007J0702017
5 008J0302417
6 DH0306117
7 GCC072084
8 009J0307617
9 010J0404617
10 DHCO211417
11 JCP052084(Flip)
12 001C0610017(Flip)
13 GFA206
14 GFA106
10 1 -4 1/4"
9 1 -0
8 2 -8 15/16"
7 3 -0
6 3 1/16"
5 1 -6 15/16"
4 3 -4 1/4
3 1 -9
2 3 -8 1/4
1 3 -6"
n Dimension Key
CO
Non -Std Secondary
Part
001C0610017
001C0610017(Flip)
C�7
1 UNLESS NOTED USE 1/2 X 1 1/2 A -325 SNUG TIGHTENED BOLTS FOR GIRT LAP
GIRT TO FRAME, FLANGE BRACE TO FRAME, FLANGE BRACE TO GIRT
JAMB AND HEADER CONNECTIONS.
2. WIND AND FLANGE BRACING ARE AN INTEGRAL PART OF THE WALL STRUCTURAL
SYSTEM AND SHOULD BE PROPERLY INSTALLED PRIOR TO ERECTION OF WALL
AND ROOF SHEETS. REMOVAL OR ALTERATION OF WALL BRACING WITHOUT
PRIOR AUTHORIZATION IS PROHIBITED.
Part Schedule
Thick Depth Lap
0 0590 8 1/2
0 0590 8 1/2"
THE VP ENGINEER 5 SEAL APPLIES
ONLY TO THE WORK PRODUCT OF
VP AND DESIGN AND PERFORMANCE
REQUIREMENTS SPECIFIED BY VP
THE VP ENGINEER S SEAL DOES
NOT APPLY TO THE PERFORMANCE
OR DESIGN OF ANY OTHER PRODUCT
OR COMPONENT FURNISHED BY VP
EXCEPT TO ANY DESIGN OR PER-
FORMANCE REQUIREMENTS
SPECIFIED BY VP
T
u
01CO511717
a
61
12 -11 1/4
(c)
o Framed Opening Locations
Id Width Height Sill Ht
FO1 3 -0 3 -6 3 -6
FO1
V
U
SECONDARY ELEVATION AT 3
2
VP Ref: Shane Name Scale House, Wall 3
THIS DRAWING, INCLUDING THE INFORMATION HEREON
REMAINS THE PROPERTY OF VP 8 NGS
T IS PROVIDED SOLELY FO CTINGT ILDING
DESCRIBED IN THE APPLICABLE CHASE ORDER AND
SHALL NOT BE MODIFIED, REPRO C DOR USED OR
ANY OTHER PURPOSE WITHOUT IOR WRITTEN
APPROV LOF VP LDINGS,
THE GENERAL CONTRAC ND/OR ER TOR LEL
RESPONSIBLE FOR ACCU ATE. GOOD UALITY WORKMAN
ERECTING THIS BUILDI CONFOR CE WITH THIS
DRAWING. DETAILS REN N TNI DRAWN
ALL APPLICABLE VP E CTION S
AND NDU R STAND RDS PER
ERECTIO FTEMPOR
BRACIN
Frame To Dimen
BL Jamb -L 6 -11 1/4
VP Buildings, Inc.
3200 Players Club Circle Memphis TN 38125
R VI
ATE
11/9/2005
DESCRIPTIO
8:53:03
'EXPIRES 07 18- oc.. _1
FOR APPROVAL NOT FOR CONSTRUCTION
SECONDARY ELEVATION AT 3
BUILDER
CHG Building Systems, Inc.
'CUSTOMER ET Environmental
''LOCATION Port Angeles, Washington
'PROJECT Port Angeles Transfer Station
'BUILDERS POO 15226
FILENAME CA0501694 -01OE1 vpc
JOBS
i CA0501694 -01
DATE
10/4/2005
VP BUILDINGS I DRAWN/CHECK
V MWPRNAEN MDS
PAGE 11
VPC VERS 5.3b
()Part Mark Key
1 005J0305417
2 004J0305417
3 DH0108017
7 6
6 3
5 2
4 4
3 3
2 1
1 1
0
6"
-0
8"
6
0
M
00
N
Dimension Key
1
F03
1 UNLESS NOTED USE 1/2 X 1 1/2 A -325 SNUG TIGHTENED BOLTS FOR GIRT LAP
GIRT TO FRAME, FLANGE BRACE TO FRAME, FLANGE BRACE TO GIRT
JAMB AND HEADER CONNECTIONS.
2. WIND AND FLANGE BRACING ARE AN INTEGRAL PART OF THE WALL STRUCTURAL
SYSTEM AND SHOULD BE PROPERLY INSTALLED PRIOR TO ERECTION OF WALL
AND ROOF SHEETS. REMOVAL OR ALTERATION OF WALL BRACING WITHOUT
PRIOR AUTHORIZATION IS PROHIBITED
CNJ
02C1707417
02C1707417(Flip)
16 -8"
THE VP ENGINEER S SEAL APPLIES
ONLY TO THE WORK PRODUCT OF
VP AND DESIGN AND PERFORMANCE
REQUIREMENTS SPECIFIED BY VP
THE VP ENGINEER S SEAL DOES
NOT APPLY TO THE PERFORMANCE
OR DESIGN OF ANY OTHER PRODUCT
OR COMPONENT FURNISHED BY VP
EXCEPT TO ANY DESIGN OR PER-
FORMANCE REQUIREMENTS
SPECIFIED BY VP
10
_o
�ti
�O
O
2 (CD
1:4 -11 1/4
SECONDARY ELEVATION AT B
VP Ref: Shaoe Name Scale House. Wall 4
THIS DRAWING INCLUDING THE INFORMATION HEREON
EMAINS THE ROPERTY FVPB ILOINGS.
ITISPROVID D50L ERECDNG THE LDI
DESCRIBED IN THE APPLICABLE PURCHASE ORDER
S ALL NOT ODIF ED, REPRODUCED OR USED FOR
Y OTHER POSE WITHOUT PRIOR WRrrTEN
ROVAL OF VP B WINGS
o Framed Opening Locations
Id Width Height Sill Ht Frame To
FO1 1 -8" 3 -0 4 -0 1 Jamb -L
F02 3 -0 3 -6" 3 -6 2 Jamb -L
F03 4 -0" 3 -6" 3 -6" 1 Jamb -L
THE GEN RAL CONTRA DIOR ERECTO IS SOLEL
SPON FOR ACCURATE. GOOD DUALITY WORKMANS
ERECTING THIS ILD N CONFORMAN E WITH THI
DRAW' G, DE IL5 REFERENCED N THIS DRAWING,
ALL AP LICABLE VP R CTION G DES.
AND NDUSTR LAND RDS PERTAININ PR PER
RECTIO THE SE OF TEMPOR RY
ACI
F02
CND
REV'
DATE
11/9/2005
tPBX001
16 -3 1/4
VP Buildings, Inc.
3200 Players Club Circle Memphis TN 38125
IBY I
I I
NTS
Bracing Member Schedule
Dimen
6 BX001
2 _6 "02100
2 -8"
0A325 Bolt Schedule
Id Qty Bolt Diam Bolt Length
1 4 3/4 1 1/2
2 2 3/4 2
02C1702617
02C1702617(Flip)
DESCRIPTION
Description Design Lgth
3P 6" x 3/16 flg 0 1345" x 8 web 16 -3 1/4
2L 3 0 x 3 0 x 0 1875 0 375 3 -5 7/16"
Washer
FOR APPROVAL NOT FOR CONSTRUCTION
SECONDARY ELEVATION AT B
'BUILDER CHG Building Systems, Inc.
'CUSTOMER ET Environmental
IILOCATION Port Angeles, Washington
'PROJECT Port Angeles Transfer Station
180115ER5 POs 15226
8:53:04 FILENAMe CA0501694-010E1 vpc
OB
CA0501694 -01
DATE
10/4/2005
VP BUILDINGS DRAWNICHECK
vARWPRLCEN MDS
VPC VERS 5.3b PAGE 12
Covering Schedule
Id Qty Length
#118 18 6 -3 1/4
#119 18 6 -3 1/4
Oper Code 2 =SQ SQ
Finish K =KXL
Color EW= Egyptian White
Type Gage
SSR 24
SSR 24
n
L
OP
2
2
Ice Damming Conditions Exist
The SSR roof on this project has been
detailed for a UL90 rating Construction #113
(Field Repair Fastener)
(1 bags) #55308 #17 -14x1" S S Roof Fastener
1 PRE- DRILLING 1/8 DIAMETER HOLES FOR ROOF STRUCTURAL FASTENERS
MAY BE REQUIRED AT 11 GAGE PURLINS, NESTED PURLINS, PURLIN LAP
LOCATIONS, AND /OR SECONDARY STRUCTURAL BEAMS
2. ROOF SHEETS ARE AN INTEGRAL PART OF THE STRUCTURAL SYSTEM,
REMOVAL OR ALTERATION WITHOUT PRIOR AUTHORIZATION IS PROHIBITED.
3. SEE JOB DETAILS FOR SHEETING AND TRIM FASTENER SPECIFICATION.
Fin
K
K
1 1 -5 5/8 Starter Panel (Cut Dim 1 -6 5/8
Dimension Key
Color
EW
EW
THE VP ENGINEER S SEAL APPLIES
ONLY TO THE WORK PRODUCT OF
VP AND DESIGN AND PERFORMANCE
REQUIREMENTS SPECIFIED BY VP
THE VP ENGINEER 5 SEAL DOES
NOT APPLY TO THE PERFORMANCE
OR DESIGN OF ANY OTHER PRODUCT
OR COMPONENT FURNISHED BY VP
EXCEPT TO ANY DESIGN OR PER-
FORMANCE REQUIREMENTS
SPECIFIED BY VP
Trim
Id
Ti
T2
T1
Schedule
Parts
SRCF06 (4)SRCF10 SRCM06 (4)SRCM10
PPC3 SRR4
(18) #11:
(18) #11O
34 -11 1/4
ROOF COVERING PLAN
VP Ref: Shane Name scale House
THIS DRAWING. INCLUDING THE INFORMATION HEREON
REMAINS THE PROP RTY OF VP BU LDINGS.
IT IS PROVIDED SOLEL FOR ERECTING THE BUILD'
DESCRIBED N THE APPLICABLE PURCHASE ORDER AND
SHALL NOT MODIFIED. REPRODUCED OR USED FOR
ANY OTHER RPOSE WITHOUT PRIOR WRITTEN
APPROVAL OF IUD NGS
THE GENERAL CONTRACT R AND/OR ERECTOR IS SOLELY
SPONSI FOR ACCURATE, GOOD OUALT' WORIWANSHI
RECTIN 15 ILDI CONFOR NCE WITH THI
DRAWING. DETAILS RE CEO N T DRAWI
LL APPLICABLE VP CTION GU DES
NDUSTRY STAND ROS PERTAIN ROPER
CTION CLUDIN HECORREC USE FTEMPORARY
BRAG NG
VP Buildings, Inc.
3200 Players Club Circle Memphis TN 38125
REV'
I I
DATE
11/9/2005
Color
Match Roof Color
Patrician Bronze
IPTION
8:53:05
Details
RC34A7 RC34H1 RC34H3 RC34H4
RC34H5 RC34H6
n
T2
ROOF COVERING PLAN
BUILDER
CHG Building Systems, Inc.
ICUSTOMER Environmental
'LOCATION Port Angeles, Washington
(PROJECT Port Angeles Transfer Station
'BUILDER'S PON 15226
FILENAME: CA0501694 -010E1 vpc
1 EXPIRES 07 18- °G 1
FOR APPROVAL NOT FOR CONSTRUCTION
OBf
CA0501694 -01
DATE
10/4/2005
VP BUILDINGS I
DRAWN/CHECK
MDS
VPC VER 5.3b PAGE 13
Covering Schedule
Id Qty Type Start
#124 3 PR 9 -2 3/8"
#125 3 PR 9 -2 3/8"
Oper Code 1 =SQ SQ
Finish K =KXL
Color EW= Egyptian White
Length Gage OP
24 1
24 1
1 WALL SHEETS ARE AN INTEGRAL PART OF THE STRUCTURAL SYSTEM,
REMOVAL OR ALTERATION WITHOUT PRIOR AUTHORIZATION IS PROHIBITED.
2. SEE JOB DETAILS FOR SHEETING AND TRIM FASTENER SPECIFICATION.
3. PRE DRILLING 1/8 DIAMETER HOLES FOR WALL STRUCTURAL FASTENERS
MAY BE REQUIRED AT 11 GAGE GIRTS, NESTED GIRTS, GIRT LAP
LOCATIONS, AND /OR SECONDARY STRUCTURAL BEAMS
Fin
K
Color
EW
EW
C%
CO
P1
M
CV
OD
Increment
6
6"
T7
Direction
Left to Right From Peak
Right to Left From Peak
THE VP ENGINEER S SEAL APPLIES
ONLY TO THE WORK PRODUCT OF
VP AND DESIGN AND PERFORMANCE
REQUIREMENTS SPECIFIED BY VP
THE VP ENGINEER S SEAL DOES
NOT APPLY TO THE PERFORMANCE
OR DESIGN OF ANY OTHER PRODUCT
OR COMPONENT FURNISHED BY VP
EXCEPT TO ANY DESIGN OR PER-
FORMANCE REQUIREMENTS
SPECIFIED BY VP
#125
T2-6 -6 11/16
T5
—T6
E,
H
T8
T5
T6
T3
12 -11 1/4"
Trim Schedule
Id
T1
T2
T3
T4
T5
T6
T7
T8
H
COVERING ELEVATION AT 1
VP Ref: Shape Name Scale House, Wall 1
Parts
CT10
(2)RFR10 RKC15 RKF16 (2)RSB10 (2)RSC10
(0 6)BA1 (2)BT10
DF05 JTO5
DF05 HTS05
TDFH05
BS1 GGC2 MCC1 PRF1
PPC3 SRR4
T2 -6 -6 11 /16"
T5
T6—
THIS DRAWING, INCLUDING THE INFORMATION HEREON
EMAINS THE PROPERTY OF VP ILDINGS
R ROVIDED SOLELY FOR ERECTIN HE BUILDING
DESCR N THE APPLICABLE P CHASE ORDER AND
SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR
ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN
ROVAL F VP BUILD
THE NERAL CONTRACTOR AND/OR ERECTOR IS SOLELY
SPON I LE FOR ACLU ATE, GOOD DUALITY WORKMANSHIP
CTING THIS BU NG IN CON ORMANOE WITH THIS
D AWI G DETAILS REF RENCE NTHIS DRAWIN
ALL AP LICABLE VP ERECTOR DES
AND USTRY STANDARDS PERTAIN TO PROPER
CT10 INCLUD NG THE COR OF TEMPORARY
(3) #124
T7
IREVI DATE
r1
11/9/2005
1
1 1
1
VP Buildings, Inc.
3200 Players Club Circle Memphis TN 38125
NTS
DES IP ION
8:53:08
Color Details
Match Wall Color WC20A1
Patrician Bronze RC10A1 RC30A1 RS10G1 WC10A1
Patrician Bronze EN52A1 RCOOA1 WCO1A3 WCO4A1
Patrician Bronze WC24A1
Patrician Bronze WC24A2
Patrician Bronze WC24A4
Patrician Bronze RC38A1
Patrician Bronze RC34H5 RC34H6
EXPIRES 07 18- oC I
FOR APPROVAL NOT FOR CONSTRUCTION
COVERING ELEVATION AT 1
BUILDER
I CHG Building Systems, Inc.
IcusTOMERET Environmental
I LGCA 0 Port Angeles, Washington
(PROJECT Port Angeles Transfer Station
(BUILDERS Pp 15226
FILENAME: CA0501694-010E1 vpc
VPC VERSIO 5.3b
JOB
CA0501694 -01
DATE
10/4/2005
DRAWWCHECK
MDS
P00014
Covering Schedule
Id Qty Type
#126 12 PR
Oper Code 1 =SQ SQ
Finish K =KXL
Color EW= Egyptian White
to
CO
Length Gage OP
8 -5 3/4" 24 1
T10
1 WALL SHEETS ARE AN INTEGRAL PART OF THE STRUCTURAL SYSTEM,
REMOVAL OR ALTERATION WITHOUT PRIOR AUTHORIZATION IS PROHIBITED.
2. SEE JOB DETAILS FOR SHEETING AND TRIM FASTENER SPECIFICATION.
3. PRE DRILLING 1/8 DIAMETER HOLES FOR WALL STRUCTURAL FASTENERS
MAY BE REQUIRED AT 11 GAGE GIRTS, NESTED GIRTS, GIRT LAP
LOCATIONS, AND /OR SECONDARY STRUCTURAL BEAMS
Fin
K
T5
T6
Color Direction
EW Right to Left
H
rn
THE VP ENGINEER 5 SEAL APPLIES
ONLY TO THE WORK PRODUCT OF
VP AND DESIGN AND PERFORMANCE
REQUIREMENTS SPECIFIED BY VP
THE VP ENGINEER 5 SEAL DOES
NOT APPLY TO THE PERFORMANCE
OR DESIGN OF ANY OTHER PRODUCT
OR COMPONENT FURNISHED BY VP
EXCEPT TO ANY DESIGN OR PER-
FORMANCE REQUIREMENTS
SPECIFIED BY VP
T5
T6
T2
(12) #12C
T3
-34 -11 1/4
Trim
Id
Ti
T2
T3
T4
T5
T6
T7
T8
T9
T10
COVERING ELEVATION AT A
VP Ref: Shaoe Name Scale House. Wall 2
THIS DRAWING INCLUDING THE INFORMATION HEREON,
MAINS THE ROPERTY 0 ILO NG5
IT'S ROVID SOL FOR CTING THE BUILDING
8E0 N THE APPLICABLE HASE ORDE AND
SHALL NOT BE MODIFIED. REPROD C D OR USED OR
ANY OTHER PURPOSE WITHOUT P I08 WRITTEN
ROVA OF BU NGS.
Schedule
Parts
CT10
EG202 EG162 (3)PCA10A PCAO5A (19)STR4
(1 7)BA1 (4)BT10
DF05 JTO5
DF05 HTS03
TDFH03
DF05 HTS05
TDFH05
DE1 DN1 DS10 (2)DST1
BS1 GGC2 MCC1 PRF1
THE GENERAL CONTRACTOR AND/OR RECTOR 5 SOLELY
RESPON IDLE FOR ATE, GOOD QUALITY WORKMANS
ERECTINGTHI D CONFORMANCE WITH THIS
RAWING. DE AILS FEREN N DRAWI
LL APPLICABLE VP RECTOR DES
ND NDUSTRY STANDARDS N TO ROP
ERECTION CLU G THE CAR OF TEMPORARY
BR NG.
VP Buildings, Inc.
3200 Players Club Circle Memphis TN 38125
5 VI
I I
I I
ATE
11/9/2005
c
H
DESCRIPTION
Color Details
Match Wall Color WC20A1
Patrician Bronze RCO3A2 RC32A1 RC3BE2 RC61A6 WCO4AJ W
Patrician Bronze EN52A1 RCOOA1 WCO1A3 WCO4A1
Patrician Bronze WC24A1
Patrician Bronze WC24A2
Patrician Bronze WC24A4
Patrician Bronze WC24A2
Patrician Bronze WC24A4
Match Wall Color RC38F1
Patrician Bronze RC38A1
T7
T8
H
T5
T6—
FOR APPROVAL NOT FOR CONSTRUCTION
COVERING ELEVATION AT A
'BUILDER CHG Building Systems, Inc.
IcusTOMERET Environmental
'LOCATION Port Angeles, Washington
I PRDJEGT Port Angeles Transfer Station
'BUILDER'S POP 15226
8:53:11 FILENAME CA0501694 -010E1 vpc
EXPIRES 07 1 &cam
JOB
CA0501694-01
DATE
10/4/2005
VP BUILDINGS DRAWN /CHECK
YARWPRLDEN MDS
VPC VERSION 5.3b PAGE 15
Covering Schedule
Id Qty Type
#127 3 PR 9
#128 3 PR 9
Oper Code 1 =SQ SQ
Finish K =KXL
Color EW= Egyptian White
Start Length Gage OP
2 3/8 24 1
2 3/8 24 1
1 WALL SHEETS ARE AN INTEGRAL PART OF THE STRUCTURAL SYSTEM,
REMOVAL OR ALTERATION WITHOUT PRIOR AUTHORIZATION IS PROHIBITED.
2. SEE JOB DETAILS FOR SHEETING AND TRIM FASTENER SPECIFICATION.
3. PRE DRILLING 1/8 DIAMETER HOLES FOR WALL STRUCTURAL FASTENERS
MAY BE REQUIRED AT 11 GAGE GIRTS, NESTED GIRTS, GIRT LAP
LOCATIONS, AND /OR SECONDARY STRUCTURAL BEAMS
Fin
K
K
Color
EW
EW
OD
Increment
6"
6
H
T9
Direction
Left to Right From Peak
Right to Left From Peak
L
f 1 -9"
1
THE VP ENGINEER S SEAL APPLIES
ONLY TO THE WORK PRODUCT OF
VP AND DESIGN AND PERFORMANCE
REQUIREMENTS SPECIFIED BY VP
THE VP ENGINEER S SEAL DOES
NOT APPLY TO THE PERFORMANCE
OR DESIGN OF ANY OTHER PRODUCT
OR COMPONENT FURNISHED BY VP
EXCEPT TO ANY DESIGN OR PER-
FORMANCE REQUIREMENTS
SPECIFIED BY VP
(3 #128
T2 -6 -6 11/16
3 -4 1/4
CD
a
H
H
T3
12 -11 1/4"
Trim
Id
T1
T2
T3
T4
T5
T6
T7
T8
T9
Schedule
Parts
CT10
(2)RFR10 RKC15 RKF16 (2)RSB10 (2)RSC10
(0 6)BA1 (2)BT10
DF05 JT05
DF05 HTS03
TDFH03
DF05 HTS05
TDFH05
BS1 GGC2 MCC1 PRF1
T5
T6
T7
T8
COVERING ELEVATION AT 3
X2_6 '6 11/16
7 -10
H
VP Ref: Shape Name Scale House. Wall 3
THIS DRAWING, INCLUDING THE INFORMATION HEREON
MAINS THE PR PERTY OF VP BU LDINGS,
R IS PROVIDED SOL Y FOR ERECTING THE BUILDING
CRI N THE APPLICABLE URCHASE ORDER AND
SH LL NOT BE OOIF ED, REPRODUCED OR USED FOR
ANY OTHE PURPOSE WITHOUT PRIOR WRITTEN
ROVAL OF ILDINGS
THE ERAL CONTRACT ANDIOR ER TOR 5 SOLEL
SPONSI ACCU ATE, GOOD UAUfYWORKMANS
ER GTHI CONFO MARC WITH THIS
DRAWING, DETAILS EFEREN THIS DRAWING,
ALL APPLICABLE VP ECTION S
STRY RD5 PER PROPER
G THE COR CT USE FTEMPOR
BRAG NG
OD
CO
P1
M
CO
(3) #127
VP Buildings, Inc.
3200 Players Club Circle Memphis TN 38125
REV'
II
II
I I
ATE
11/9/2005
OD
M
CO
NTS
Color Details
Match Wall Color WC20A1
Patrician Bronze RC10A1 RC30A1 RS10G1 WC10A1
Patrician Bronze EN52A1 RCOOA1 WCO1A3 WCO4A1
Patrician Bronze WC24A1
Patrician Bronze WC24A2
Patrician Bronze WC24A4
Patrician Bronze WC24A2
Patrician Bronze WC24A4
Patrician Bronze RC38A1
FOR APPROVAL NOT FOR CONSTRUCTION
COVERING ELEVATION AT 3
IPDON 'BUILDER CHG Building Systems, Inc.
rUSTOMERET Environmental
'LOCATION Port Angeles, Washington
'PRaECT Port Angeles Transfer Station
'BUILDER'S PO, 15226
8:53:15 FILENAME CA0501694 -01OE1 vpc
VPC VERS 5.3b
JOB
CA0501694 -01
DATE
10/4/2005
I DRAWN/CHECK
MDS
PAGE 16
Covering Schedule
Id Qty Type
#129 12 PR
Oper Code 1 =SQ
Finish K =KXL
Color EW= Egyptian White
OD
Length
8 -5 3/4"
SQ
n
T9
-T5
Gage OP
24 1
1 WALL SHEETS ARE AN INTEGRAL PART OF THE STRUCTURAL SYSTEM,
REMOVAL OR ALTERATION WITHOUT PRIOR AUTHORIZATION IS PROHIBITED
2. SEE JOB DETAILS FOR SHEETING AND TRIM FASTENER SPECIFICATION.
3. PRE DRILLING 1/8 DIAMETER HOLES FOR WALL STRUCTURAL FASTENERS
MAY BE REQUIRED AT 11 GAGE GIRTS, NESTED GIRTS, GIRT LAP
LOCATIONS, AND /OR SECONDARY STRUCTURAL BEAMS
Fin
K
T6
T7
Color Direction
EW Right to Left
m
E
0,
F
THE VP ENGINEER S SEAL APPLIES
ONLY TO THE WORK PRODUCT OF.
VP AND DESIGN AND PERFORMANCE
REQUIREMENTS SPECIFIED BY VP
THE VP ENGINEER S SEAL DOES
NOT APPLY TO THE PERFORMANCE
OR DESIGN OF ANY OTHER PRODUCT
OR COMPONENT FURNISHED BY VP
EXCEPT TO ANY DESIGN OR PER-
FORMANCE REQUIREMENTS
SPECIFIED BY VP
(12) #12F
T2
Trim
Id
Ti
T2
T3
T4
T5
T6
T7
T8
T1
.34 -11 1/4
Schedule
Parts
EG202 EG162 (3)PCA10A PCAO5A,(19)STR4
(1 7)BA1 (4)BT10
DF05 JTO5
DF05 HTS03
TDFH03
DF05 HTS05
TDFH05
DE1 DN1 DS10 (2)DST1
COVERING ELEVATION AT B
VP Ref: Shane Name Scale House, Wall 4
THIS DRAWING, INCLUDING THE INFORMATION HEREON
REMAINS THE PROPERTY OF VP B NG5.
RI PROVIDED SO ER CTING THE BUI
SCR BED IN THE APPLICABL CHASE ORDER AND
SHALL NOT BE MODIF ED. REPRO UCED OR US
ANY OTHER PURPOSE WITHOUT RIOR WRITTE
ROV LOF VP NOS
THE GENERAL CONTRACTOR ND'OR ERECTOR IS SOLEL
SPONSIBLE FO ACCURATE, GOOD QUALITY WORKMAN
ERECTINGTH NOON MANCE WITH TNI
RAWING. DETAILS REF RE N TNI DRAWING.
LL APPLICABLE VP ER 0110 DES
AND NDUSTRY RDB PERTAINING TO PROPER
RECTO UDI ECT OFTEMPOR
BRACING
T9
T5
0Y)
LJ
E
VP Buildings, Inc.
3200 Players Club Circle Memphis TN 38125
REVI DAT
11/9/2005
Color Detail
Patrician Bronze RCO3A2
Patrician Bronze EN52A1
Patrician Bronze WC24A1
Patrician Bronze WC24A2
Patrician Bronze WC24A4
Patrician Bronze WC24A2
Patrician Bronze WC24A4
Match Wall Color RC38F1
EXPIRES 07 18
FOR APPROVAL NOT FOR CONSTRUCTION
COVERING ELEVATION AT B
IPNO BUILDEfl
CHG Building Systems, Inc.
(CUSTOMER ET Environmental
ILOCAT1ON Port Angeles, Washington
(PROJECT Port Angeles Transfer Station
(BUILDER'S PoY 15226
8:53:18 FILENAME: CAO5O1694 -01 OE 1.vpc
s
RC32A1 RC38E2 RC61A6 WCO4A1 W
RCOOA1 WCO1A3 WCO4A1
n
JOBO
CA)501694 -01
DATE
10/4/2005
VP BUILDINGS I DRAWN/CHECK
vuxwPmcE MDS
PAGE 17
VPCVERS 5.3b
WALL BRACE
ROD
ROD CABLE BRACING AT COL. BASE
3 —PLATE OR GAGE
035.2 2/21/2005
3/16' L'' MN.
3' MAX. GAGE
(MIN. 1/2' A307 BOLTS
4' MIN. PITCH)-
HILLSIDE WASHER
FLAT WASHER
HEX NUT
FRAMES OR SUPPORT BEAMS
CLIPS, PLATES OR BOLTS
ARE NOT BY VARCO- PRUDEN
CONTRACTOR'S NOTE.
FIELD DRILL OR FIELD WELD SUSPENSION ANGLES OR PLATES.
ALLOWABLE LOAD 1 KIP PER PAR OF BOLTS
14 KIPS PER INCH OF WELD WITHOUT INSPECTION
2.8 KIPS PER INCH OF WELD WITH INSPECTION
ADD PAIRS OF BOLTS OR INCHES OF WELD TO RESIST DESIRED
CONCENTRATED LOAD. LOADS LESS THAN 500 LBS MAY BE SUSPENDED
USING CLAMPS. (1 1/2" FROM EDGE OF FLANGE).
CONCENTRATED LOADS SHALL NOT EXCEED USER DEFINED COLLATERAL
LOADING INDICATED ON THE PURCHASE ORDER AND IN VP CALCULATIONS.
SUSPENDED LOADS
FROM STRUCTURAL BEAMS
ENIDA2V1 05/01/9
L J L J L J
Q 1= SIMPLE INTERIOR
Q2= SIMPLE 1 END BAY
D 2= SIMPLE 6' END BAY
D4 =END HOLE ONLY
D 2=INSET NOTCH
D 6 =NO HOLES
21 =6
21 =6
22 =6'
24 =6
2fi =6
END BAY
END BAY
END BAY
END BAY
END BAY
SECONDARY PUNCH PATTERNS
COMMON GENERATED MARK NUMBERS
EN51 102 3/ 16 2005
1 -0' LAP
1 -6' LAP
2' -0' LAP
3' -0' LAP
4' -0' LAP
m =1
31 1
21")
34 =1
26 -1
GAGE
F
INCHES LENGTH
FFFTI(millimeters)
CATEGORY
PUNCH PATTERN
END BAY
END BAY
END BAY
END BAY
END BAY
4D= INTERIOR BAY
Al INTERIOR BAY
42 INTERIOR BAY
44= INTERIOR BAY
A6- INTERIOR BAY
1 -0' LAP
7 -6 LAP
2' -0' LAP
3' -0' LAP
4' -0' LAP
I BRO2A11
I I I
1 -0' LAP
1 -6' LAP
2' -0' LAP
3' -0' LAP
4' -0' LAP
IEN51A1I
I I I
FLANGE BRACE REQUIREMENTS:
RULE #1 ALL FLANGE BRACES ON CROSS SECTIONS MUST BE INSTALLED.
RULE #2 SINGLE FLANGE BRACES ARE REQUIRED WHEN PART MARK ON
CROSS SECTION IS NOT ACCOMPANIED BY (2).
RULE #3 FLANGE BRACES ARE REQUIRED BOTH SIDES OF THE FRAME WEB
WHEN PART MARK IS ACCOMPANIED BY (2).
RULE #4 WHENEVER POSSIBLE, PLACE SINGLE BRACES TOWARD THE
CENTER OF THE BUILDING.
RULE #5 WHENEVER POSSIBLE, PLACE ALL SINGLE BRACES ON THE SAME
SIDE OF THE FRAME WEB.
TYPICAL FLANGE BRACE CONNECTIONS
11NUOLS PUTL1 LAP DM, CONTINDUS GIRT MID NPLE PURLI AND GIRT ILVL
141
CUP RE0'D WITH
THICK RANGES
01/05/200
EN20AIn D5/31/0
PR WALL PANEL MARK ND.
PR R00F PANEL MARK NO.
PR RIDGE PANEL MARK N0.
01520103 05/31 /2005
END BAY
2 "1
3" 4 1 /2'
a
/2 LIM REOU RE 3 BOLTS EACH END PLPUN LAP
8 FRAME
1 INTERIOR BAY
VARB I VARIES
TOWARD THE
CENTER OF
THE BUILDING
7 SECONDARY
E ROOF
SCOND
S
FLANGE RACE FLG. BRACE THIS SIDE WHEN
(0 0 (5(B -)5 SNGLE BRACE IS REQUIRED
FLANGE BRACE MAY REQUIRE
FIELD COPING AT FRAME WEB
FINGER SHIM AS
REQUIRED
0111141
MAY BE STRAIGHT
OR TAPERED MEMBER
FLAT SHIM AS
REQUIRED
BETWEEN BOLTS
1 -0"
12'
TYP
12'
TIP 1
SHIM2I I
"a
W F F I I E G G O C C C F- FEET
LENGTH CODE I INCHES
R F F I I E C C O C C C
LENGTH CODE
6 1 6 0 0 0 C 0 5
LENGTH CODE
36' COVERAGE
TYP
2 71/��
PANEL RIB ROOF AND WALL PANEL (PR)
RPR WALL PANEL MARK NO. R R F F I I E G C O C C C
LENGTH CODE
36' COVERAGE
2 3131/
TrP
RPR WALL PANEL
PR ROOF PR /RPR WALL PANELS
THE VP ENGINEER S SEAL APPLIES
ONLY TO THE WORK PRODUCT OF
VP AND DESIGN AND PERFORMANCE
REQUIREMENTS SPECIFIED BY VP
THE VP ENGINEER S SEAL DOES
NOT APPLY TO THE PERFORMANCE
OR DESIGN OF ANY OTHER PRODUCT
OR COMPONENT FURNISHED BY VP
EXCEPT TO ANY DESIGN OR PER-
FORMANCE REQUIREMENTS
SPECIFIED BY VP
E EIGHTHS
G GAGE
O OPERATION
C FIN /COLOR
SMOOTH
EXTERIOR
SURFACE
BEARING EDGE
IBR06BDI
I I I
TYPICAL BOLTING
PLATES, FACADE
OR CANOPY
CONNECTIONS
NOTE: FIELD CUT SHIMS TO
DESIRED DIMENSIONS TO
ACHIEVE DESIRED RESULTS
SHIMS ARE MADE
FROM .059" MATERIAL
IEN10A2I STANDARD SHIM PROCEDURE EN20A11
1 1 1 TYPICAL AT ANY BOLTED CONNECTION 1 I
1 1 3/16'
L
7
SMOOTH
EXTERIOR 1 3/16'
SURFACE
IEN52A1
I I
NSER6 SAG ANGLE TAB NTO PUR SL01S
AND BEND TAB FLAT.
REQU RED ANGLES S
AT RIDGE
AT 11 1/2" PURLINS
NE OF B
SAG ANGLE (SA-)
(DO NOT USE ERECTION SAG ANGLES IN PURUN
SPACES OCCUPIED BY X -ING SAG ANGLES,
X -ING SAG LOCATIONS ARE REQ'D BY DESIGN)
OPTIONAL ERECTION SAG ANGLES IBRO9A41
I I I
SAG ANGLE INSTALLATION
BwwMn 6/01/2005
NOTES
RC00A 4/19/2005
NOTES:
-WHEN SAG ANGLE SLOTS IN ADJACENT
PURUNS DO NOT ALIGN, FIELD BEND THE SAG
ANGLE TAB AND ATTACH TO PURUN WITH A
1/4 -14 x 1 1/4' STRUCT FSNR (55307)
-USE UPPER SET OF SLOTS AT 11 1/2
PURUNS
BOLTING PLATES
INSTALLATION INSTRUCTION
EN20A2Y2 1/30/0
Z RIDGE
HARD FLAT WASHER
NUT
ERECTOR NOTE
TENSION CONTROL BOLT
TENSION CONTROL BOLT
PURUNS
2. ALL PANEL AND TRIM SURFACES MUST BE FREE OF DIRT AND
OIL AT MASTIC AND SEALANT LOCATIONS.
BEND TAB FLAT
INSTALLATION OF TENSION CONTROL
BOLTS MAY NOT BE POSSIBLE IN
AREAS WHERE EXTREME PITCH.
STIFFENER LOCATION. BEAM DEPTH
OR OTHER OBSTRUCTIONS MAY
OCCUR. IN THESE CASES,
SUBSTITUTION OF A -325 NUTS
AND BOLTS WOULD BE REQUIRED.
THESE NUTS AND BOLTS ARE NOT
PROVIDED BY VP BLDGS.
n 1
1 MIN, 3/4" DIA. BOLT
11 1/8' MINI 7/8' DIA. BOLT
11 1/4" MINI 1 DIA BOLT
I I
SHEAR WRENCH (NBVP) REQ'D FOR INSTALLATION OF TENSION CONTROL BOLTS.
EN20A2
I I
1 STANDARD ERECTION DETAILS (SED) SUPERSEDE SIMILAR DETAILS
FOUND IN THE ERECTION GUIDES. REFER TO THE ERECTION
GUIDES FOR OTHER DETAILS, INSTALLATION PROCEDURES AND
ACCESSORIES NOT DESCRIBED IN THE SEWS.
THIS DRAWING, INCLUDING THE INFORMATION HEREON
REMAINS THE PROPERTY OF VP UILDINGS
R IS PROVIDED S FOR ERECTING THE BUILD
DESCRIBED N THE APPUCABLE PU HASE OR AND
HALL NOT BE ODIFIED, REPRODUCED OR U5 WE
ANY OTHER PURPOSE THO PR R WRITTE
APPROVAL OF V NG5
THE RAL CONTRACTOR 0/OR ER CTOR LS SOLELY
RESPONS FOR ACCU ATE, GOOD LTIY WORKMAN
IN CT! GTH DI N CONFORMANCE WRHTHI
DRAWING, DETAILS EFER CEO THIS AWE
AL AP LICABLE VP REC G 5
STRY RDS THIN TOP
CTIO HE RECT EOFTEMPOR
BRAG
PR ROOFS
X -ING SAG ANGLES (SA_)
(REQUIRED AT ALL LOCATIONS SHOWN
ON THE RODE SECONDARY DRAWING,
THEY ARE REO'D PER DESIGN AND
AND CANNOT BE OMRED.)
SAG ANGLES X -ING IBRO9A51
8 1/2 11 1/2" PURLINS (REQ'D PER DESIGN) 1 I I
BRD9A5Y5 0/01/2003
FULL PEN WELD SPLICE
I
M SOE *25HE0 PU3
1 WASHER 1(0 HEAD NU(
REOO EACH END
SSR PANEL
CLIP
EN3551 09/06/225
3/16' BEAD OF
NON- SKINNING
LA
TUBE SEALANT
(80270
RA 03 /01/90
IREv I
'SHOP SPLICE DETAILS'
11115
6'
ROD LENGTH
(AS SHOW ON LRECTON DRAWINGS)
.13
THREAD BOTH ENDS
WITHOUT TURNBUCKLE EJ
H56)E WASHER, TUT
WASHER, NIX NUT
REO'0 EACH END
RNBI1C10E
a€4 P—ylL till IIII
N Ie 16
2-D•
1 ROD LENGTH
(AS SHOWN ON ERECTION ORAWNGS)
RB ROD
THREAD BOTH ENDS
WITH TURNBUCKLE
SSR RIB
MALE HEM
RODS THAT RIO. SHOP SPUCE
ARE TO BE 5PUCEO BY USING
ONE oT THE NLTHOD5 SHOWN.
ROD BRACE ASSEMBLY
NOTE: ADDITIONAL SEALANT SHOULD BE APPUED TO
ALL SSR EAVES, ROOF CURBS AND AREAS ADJACENT
TO WALL TO ROOF, ROOF HEIGHT CHANGES AND
STEPPED ROOF EXPANSION JOINTS. R IS RECOMMENDED
THAT AREAS ADJACENT TO ROOF HEIGHT CHANGES
COVER AT LEAST 3 SIDELAPS WITH THE SEALANT
IRCOOA1 SSR PANEL SIDELAP
I I
VP Buildings. Inc.
3200 Players Club Circle Memphis TN 38125
DA BY 1
11/9/2005
INSERT SAG ANGLE TAB INTO PURLNI SLOTS
AND BEND TAB FLAT.
NOTE WHEN SAG ANGLE SLOTS ADJACENT
PURUNS DO NOT A1GN, FIELD BEND THE SAG
ANGLE TAB AND ATTACH TO PURUN WITH A
1/4 -1 /4' STRUCT FSNR (55307)
SSR SLR
ADDITIONAL WEATHERSEAL AT ICE DAMMING COND.
DES IPTION
PURLINS
BEND TAB FLAT
2081NG NUT
COUPUNG NUT SPLICE
USN WASHER, FW
WASHER 11E% HEAD. 629' ROD
REIM EACH END PAD
11 I +I
R ROD LENGTH
(l5 SHOWN ON ERECTION DRAWINGS) Fe.. R.1
ROD PADS TTEND
111111 k1
ROD POD
PPD r 08110LCKL PAD
e
MALL
ROD LENGTH
(AS 5.00.1 00 EREG110N DRAWN GS)
RD RK ROD
ROD PAD BOTH ENDS
DRAWING I EN30A1.
I I
APPLY SEALANT BOTH OVER
AND UNDER CUP TAB AT
55R CUP LOCATIONS
*20' MIN. DIST AT LOW EAVE,
FULL LENGTH ADJACENT TO
ROOF HEIGHT CHANGE AREA
OR 10' MIN OAST FOR PANELS
BELOW WALL TO ROOF AREA
1 FF
10:21'17
TFj
SELF DRILLING FASTENER OR BOLT
AT CENTERUNE OF PURUN OR HIGHER.
FIELD DRILL HOLES.
PURUN
1/2' OR LESS)
A
CONTRACTOR'S NOTE: ANY LOADS OVER 400 LOS. APPUED TO VP MEMBERS
SUCH AS HVAC, LIGHTING, DUCTING, PIPE SUPPORTS ETC. MUST BE LATERALLY
BRACED TO THE MAIN BUILDING'S LATERAL LOAD RESISTING ELEMENTS (PURUN
BRACING STRUTS OR PRIMARY FRAMES) AS REQUIRED BY CODE
FOR SEISMIC LOADS. BRACING MUST BE PROVIDED AND INSTALLED BY CONTRACTOR
AND MUST RESIST LATERAL LOADS EQUAL TO THE WEIGHT OF THE SUSPENDED
UNIT OR AS REQUIRED BY CODE, WHICHEVER IS LESS.
SUSPENDED LOADS IEN10A1I
FROM PURLINS 100 LB. LOADS OR GREATER' 1 1
100102 0/25/05
F FEET G GAGE
I INCHES 0 OPERATION
E EIGHTHS C FIN /COLOR
PANEL /COVERING
W 1 3 1 1 7 2 6 1 K T D
F F I I E G G❑ C C C
LENGTH CODE
INSULATION
I B 1 3 0 1 0 3 6 0 3 0 W .V
F F F I I I I I I E C C
LENGTH WIDTH THK CODE
SECONDARY (STANDARD)
O 1 6 1 9 1 1 4 1 7
F F I I E G G
LENGTH CODE
SECONDARY (SPECIAL)
0 0 1 6 1 9 1 1 4 1 7
F F I I E G G
LENGTH CODE
ROD BRACING
O 3 R A 2 5 1 0
2 6 F F I I
DIA LENGTH
MARK NUMBER KEY
COMMON GENERATED MARK NUMBERS
EN55A1 1/05/2005
ROD HANGER OR UNISTRUT AS NEEDED.
I RCO3A2I
I I FO 4PPROVAL NOT FOR CONSTRUCTION
BUILDING SED'S
BUILDER
CHG Building Systems, Inc.
1cu5TOMERET Environmental
1LOCATION Port Angeles, Washington
1PROJECT Port Angeles Transfer Station
1*2I1.0005 P00 15226
FI1(NAME CA0501694 -D1 OE1 vpc
ANGLE CLIP, BOLTS, UNISTRUTS, R00 HANGER
AND CLAMPS NOT BY VARCO PRUDEN.
FIRE SPRINKLER HANGER SYSTEM MUST
BE CAPABLE DF RESISTING 250 LOS. PLUS
WEIGHT OF WATER FILLED PIPE PER CODE
OTHER SUSPENDED LOADS EXCEEDING 100
LBS, MUST BE SUSPENDED SIMILAR TO THIS
DETAIL DD NOT CLAMP TO 60170M FLANGES.
CX*
CGX*
WCX*
1 EXPIRES 07 18-
VPC VER 5.3b
COLUMN (PLATE)
COLUMN (GAGE)
COLUMN (HOTROLL)
RBX* RAFTER (PLATE)
BGX* RAFTER (GAGE)
WRXO RAFTER (HOTROLL)
TRX* TRUSS RAFTER
ICX* INTERIOR COLUMN
PCX* PIPE COLUMN
TCX* TUBE COLUMN
EPXW
EGX* ENDPOST (GAGE)
ENDPOST (PLATE)
MD:1 CANOPY (PLATE)
DCCBX11x CANOPY (GAGE)
CDX* PIGGYBACK CANOPY
EN50A1I
I I I
O
CA0501694 -01
V DATE B
10/4/2005
VP BUILDINGS
AR2PRwEN I DRAWN/CHECK MDS
PAGE 18
RAKE SUPPORT
CAP (RSC
1/4 -14 1 1/4"
STRUCT FSNR
(55307)
2' -0" 0.C.
RAKE
SUPPORT
BRACKET
(RSB
NOTE
SEE ERECTION DRAWINGS
FOR FIELD CUT STARTER
PANEL DIMENSION
SSR STARTING RAKE
PR, VR OR RPR WALL
5/31/2005
USE 1/4 -14 1 1/8"
S.S. ROOF STRCH
FSNRS AT ALL
LOCATIONS
4' TRIM LAP
FIELD CUT PANEL STIFFENER (PS4)
CUT TO BEAR ON SSR STIFF
SSR PANEL
STIFFENER (P54
3/16 7/8'
TAPE MASTIC
(80345)
SSR SEAM CAP AT HIGH RIB
SSR AT RIDGE PANEL SPLICE
RC34HOV2 0/24/2001
5 TR1N
ENDWALL OR FIELD BEND 1 LIP
RAKE EXTENSION ON SSR PANEL
START PANEL DIM
USE 3/16" 7/8" 9" STRIPS
28' OF TAPE MASTIC OVER RIBS
AND 3/16" 7/8" 3" STRIPS
ON EACH SIDE OF RIBS
(80347)
NOTE. VP200 RIVET
SHOULD BE INSTALLED
AFTER INSTALLATION
OF EAVE GUTTER
FIELD DRILL (1)
3/16' DIA HOLE
IN SSR PANEL
AT EACH RIVE'
LOCATION.
GUTTER STRAP
2' -0 0.C.
(STR4)
VP200
RIVET
0
__L_
APPROX. 3 5/8'
5 EOUAL SPACES
SEE EAVE DETAIL IRC32••I RC37"
FOR EAVE GUTTER
ATTACHMENT I 1 I
SECTION
SSR
PANEL
GUTTER STRAP ATTACHMENT
SSR ROOF (ICE DAMMING)
20303721 05/02/2042
3 1/2" EACH
VP200 RIVET
(UPPER HOLES)
3/16" 7/8" TAPE
MASTIC (80349)
55R
RIB
1 VP20
1 RIVET
SSR ROOF
CLIP
FASTEN PANEL TO (RSC)
WITH 1/4 -14 1 1/8"
S.S. STITCH FSNR
4 -0' O.C.
1/2"
IRC34H3
I I
SEAL WITH TUBE
SEALANT 80507
RAKE FASCIA
(RKF20.
BOTTOM OF
ROOF SHEET
1/4 -14 7/8"
WALL STITCH
FSNR
1' -0" 0.C.
RAKE FASCIA
RETAINER (RFR10)
BLANKET INSULATION IRC10A1I SSR RAKE TRIM
I 1 1
PR, VR OR RPR WALL
C3
R0A2V7 05/31/2005
IRC34H II FOR FLASHING
SEE 1 I LOCATION
CLEAN ALL MATING SURFACES TO BE
WEATHER SEALED. REMOVE
FABRICATING OILS, RAIN, SNOW,
ICE, DEW, DUST AND DIRT
PRIOR TO APPLICATION
OF MASTICS AND
SEALANTS.
3/16' 7/8" 3'
TAPE MASTIC
(80347) FOLDED
AND TUCKED
INTO RIB
MARK FOR
TRIM LDCATION
DO NOT USE
PENCIL
SSR RIDGE FLASHING
FASTENER AND MASTIC PATTERN
RC34N4V2 0/24/200
EAVE GUTTER (EC
DOWNSPOUT STRAP
(DST1) t FASTEN TO
WALL PANEL WITH
WALL STITCH FSNR
BEND TAB
TO SECURE BTH
HLVES OF STRAP
(DST1) TOGETHER
2 STRAPS PER
10' SECTION OF
DOWNSPOUT
DOWNSPOUT ELBOW
(DE FASTEN TO
DOWNSPOUT w/ 2 POP
RIVETS
IRC38E21 DOWNSPOUT ASSEMBLY
I 1 1 ALL SYSTEMS
2081 03/05/2004
3/16' 7/8" TAPE
MASTIC (80349)
r 11,4
SSR RIDGE COVER
(SRCF OR SRCM)
3/16" 7/8" 9"
TAPE MASTIC (80347)
OVER RIB
1/4 -14 1 1/8°
S.S. ROOF STITCH
FSNR 6' 0.C.
OUTSIDE CLOSURE
PANEL RIB (80140)
VEE RIB (80362)
RFR (80130)
NOT REO'0 OVER 2112
THE VP ENGINEER S SEAL APPLIES
ONLY TO THE WORK PRODUCT OF
VP AND DESIGN AND PERFORMANCE
REQUIREMENTS SPECIFIED BY VP
THE VP ENGINEER 5 SEAL DOES
NOT APPLY TO THE PERFORMANCE
OR DESIGN OF ANY OTHER PRODUCT
OR COMPONENT FURNISHED BY VP
EXCEPT TO ANY DESIGN OR PER-
FORMANCE REQUIREMENTS
SPECIFIED BY VP
1/4 -14 1 1/8" S.S.
ROOF STITCH FSNR
(57650) 10 PER PANEL
3/16 7/8' 3'
MASTIC (80347) EACH
SIDE OF RIB
3/16" 7/8" 28"
TAPE MASTIC
(80345) IN FLAT
OF PANEL
I I
CUT AND TAB HOLE IN
EAVE CUTTER (EG
SEAL NIPPLE TO GUTTER
CONNECTION WITH BRONZE
TUBE SEALANT (80507)
DOWNSPOUT NIPPLE
(0141) FASTEN IN
SAVE GUTTER W/
8 POP RIVETS
DOWNSPOUT (DS
FASTEN TO DOWNSPOUT
NIPPLE W/ 3 POP
RIVETS
SEE ERECTION DWGS
FOR QUANTITY OF
DOWNSPOUTS
I RC38F1 I
I I I
SSR CLOSURE
PLUG (80135)
2' 0" O.C.
SAVE GUTTER
STRAP (STR4)
1/4 -14 1 1/8"
S.S. ROOF STITCH
FSNR (57650)
(1)/STRAP
3/16" 7/8"
TAPE MASTIC
(80349) CONT
AND OVER PLUG
EAVE GUTTER
(EG
1/4 -14 1 1/8"
S.S. ROOF STITCH
FSNR. (57650)
5 PER PANEL
I RC30A1I SSR ROOF W/ EAVE GUTTER
1 I I PR, VR OR RPR WALL
RC32 1V7 05/31/2005
RAKE TO RIDGE
TRANSITION
FLASHING
(SRR
PLASTIC
PEAK CAP
(PPC
RAKE
FASCIA
(RKF
1/4 -14 7/8"
WALL STITCH FSNR
1' -0" O.C.
RAKE FASCIA
RETAINER (RFR10)
IRC34H4 SSR RIDGE TO RAKE TRANSITION IRC34H51 SSR RIDGE TO RAKE TRANSITION
I I 1
A LL WALL PANELS
G411524 5/26/200
GUTTER STRAP
(STR4)
PO410603 03/,6/2005
WALL PANEL
THICKNESS
GGC_
W.P
EAVE
PANEL CLOSURE GUTTER
ANGLE (PCA
FACE OF
WALL PANEL
I 1 1/4
W.P
SEE I STRAP
C38E FOR GUTTER
ATTACHMENT
OUTSIDE CLOSURE
PANEL RIB (80140)
VEE RIB (80362)
RPR (80130)
1/4-14 7/8" WALL
STITCH FSNR
1 -0' O.C.
3/16' 7/8' TAPE MASTIC
(80349) AT PERIMETER
OF SRR
2 LAYERS AT RIDGE RIB
1 -r1
I-a 3/e°
I RC32A1I
I I I
SEE RC34H FOR PLAN VIEW
I 1 OF TRANSODN
PANEL CLOSURE
ANGLE (PCA
WALL PANEL
\--1/4 -14 1 1/8" S.S.
RDOF STITCH FSNR (58015)
W/ 7/8" WASHER
FILL ALL HOLES PROVIDED
IN FLASHING (18)
WALL PANEL
OUTSIDE CLOSURE
SEE RC38E FOR GUTTER STRAP
ATTACHMENT
3/4" GAP
S.S. ROOF
STITCH
(5 PER PANEL)
FIELD FABRICATE
GUTTER JOINT COVER
SSR EAVE GUTTER EXPANSION JOINT IRC61A6I SSR FIXED CLIP 6 1/2" PURLINS
FOR BUILDING OVER 160' IN LENGTH 1 1 1 BLANKET S— BLOCK, T —BLOCK R —BOARD
,W 7/01/2005
THIS DRAWING, INCLUDING THE INFORMATION HEREON,
REMAIN HE PROPERTY OF VP BUILDINGS. VP Buildings, Inc.
D IS OVID D SOLELY FOR ECTING THE NG
DESCRI N THE APPLICABL PURCHASE OR AND
SHALL 0011100, R PRODUCED OR USED
ANY0 R POSEWITHOUTPRIO WRITTEN
ROVAL OF VP BUILDINGS
THE ERAL CONTRACTOR 50/05 RECTOR OLELY
RESPONSIBLE FOR ACCURATE, G000 UALNY WORKMAN
I ERECTING THIS BU LOIN N CON WITH H15
DRAW! 0, DETAILS REFEREN ED IN AWIN
ALL APPLICABLE VP ER CTION GUIDE
O INDUSTRY STANDARDS PERTAIN NG TO PROPS
ER CTIO GTHE REC SE FTEMPORARY
BRAG NG
1/4 -14 1 1/8"
S.S. ROOF STITCH
FSNR (58015)
50 PER JOINT
U1 FIELD BEND
SLOT COVER
FROM 3" 14'
ALUM STRIP
(2) EALANT TUBE
(80265)
SEALANT
m SAW CUT I SLOT IN RIDGE COVER. FASTEN SLOT COVER TO RIDGE COVER AT SLOT
WITH (2) 1/4 -1 /8' S.S. ROOF STITCH FASTENERS W/ 7/8' WASHERS (58015).
CO BEND FLASHING MATERIAL TO CONFORM TO RIB CONFIGURATION.
UNE PERIMETER OF FLASHING MATERIAL WITH (2) BEADS OF TUBE SEALANT (80265).
Q MAKE A 3" FOLD IN FLASHING MATERIAL AND ATTACH TO RIDGE COVER WITH (58015)
1/4-14 1 1 /B" 55. ROOF STITCH FASTENERS WITH 7/8' WASHERS AT 2" 0.C. ALONG ENDS.
AT FIELD O. CIIT C. AND ATTACH 18" ALUM 51RP EACH SIDE OF FLASHING MATERIAL WITH FASTENERS
2
SSR RIDGE
EXPANSION JOINT
604071.2 7/07/2
RAKE FASCIA
INSTALL (18) e. :1 ja a I
1/4 -14 1 1/8' I
S.S. ROOF STITCH i I
W/ R /8 Ile
IN HOLES I le
PROVIDED I I
5/16' BEAD OF NON
SKIN TUBE SEALANT 11
(80270) AT
PERIMETER OF b
FLASHING
1RC34H51 FDR SECTION THROUGH
SEE 1 1 1 TRANSITION
PLAN VIEW
20340523 05/26/2005
PURLIN
PSN-
PURLIN SUPPORT MEMBER (PSN)
LOCATED AT 1/3 POINIT5 IN EACH
BAY GREATER THAN 16' -0
I R Y 1
II
1 1
11
ATE
160 —0 0.C. MAX.)
SSR RIDGE TO RAKE
TRANSITION (SRR
0
2
1
NTS
18' 28" FLASHING
MATERIAL (SEJI)
2
NOTE. FIXED CUPS ARE MARKED WITH
PAINTED TAB FOR EASY IDENTIFICATION (34")
6 0 058 W A N B O S N' ,0 Ro B 1,0 94
D
V p0 a W I k UPER BL g p A)
8p0 48 1111 1HERMN-
8�
3 FOLD IN
MATERIAL
SSR RIDGE
A� COVER SRC-
3/16" 7/8' TAPE
MASTIC (60349)
AT PERIMETER OF
FLASHING (2)
LAYERS OVER RIB
RIDGE
PU RL1
s9 AG
3200 Players Club Circle Memphis TN 38125
11/9/2005 10:21'19
18" ALUM STRIP
FIELD CUT TO
12'
ATTACH EA. END OF (PSN
W/ (2) 1/4 -14 1 1/4'
STRUCT FSNR (55307)
CRAP IO
1/4 -14 1 1/8" 5.5. ROOF
STITCH FSNR
10 PER PANEL
MALE RIDGE
COVER
(SRCM
SSR
PANEL
SEE ftC34H4I FOR FSNR AND
II I MASTIC PATTERN
IRC34A71 SSR RIDGE
I I I
2600085 1/10/2004
PANEL RIB FILLER
(PRF1) FASTEN IN
PLACE W/ 4 PDP
RIVETS
PLASTIC CORNER
CAP (PCC1) OR
METAL CORNER
CAP (MCC1)
I
NOTCH DETAIL
A -A
I 1 1 ALL SYSTEMS
2X3641 1/15/1
BUILDING SED'S
SSR PANEL CUP
RAKE FASCIA
(RKF
CUT AWAY
SHADED AREA
45"
BUILDER
CHG Building Systems, Inc.
IcuSTOMERET Environmental
'LOCATION Port Angeles, Washington
'PROJECT Port Angeles Transfer Station
'BUILDER'S POP 15226
FILENAME: CA0501694 -01 OE1.vpc
C OF RIDGE
PANEL STIFFENER
7"
(PS4)
(P55) WITH RIGID BOARD
INSULATION
9" STRIP OF 3/16' 7/8
TAPE MASTIC OVER RIB
(80347) AND 28" STRIP
IN FLAT OF PANEL (80345)
EXPIRES 07 18
I RC62A1
I IFOR 4PPROVAL NOT FOR CONSTRUCTION
41,2"
FEMALE RIDGE
COVER (SRCF
SSR
PANEL
COVER ATTACHMENT IRC34H1I
1 I I
BIRD STOP (BSI)
FASTEN IN PLACE
W/ 4 POP RIVETS
GUTTER CLOSURE
(GGC FASTEN IN
PLACE W/ 10 POP
RIVETS
SEAL INSIDE
PERIMETER OF
CLOSURE W/
BRONZE TUBE
SEALANT
(80507)
EAVE GUTTER (EC
IRC34H61 EAVE GUTTER CORNER ASSEMBLY I RC38A11
1 I I
JOB 0
X40501694 -01
DATE
10/4/2005
VP BUILDINGS DMWN CHECK
V0000 4655 MDS
VPC V 5.3b PAGE 19
NOTE: FIXED CUPS ARE MARKED WITH
PAINTED TAB FOR EASY IDENTIFICATION
8 1/2" OR 11 1/2" PURLIN.
WIDEBAY OR JOIST
SSR FIXED CLIP
BLANKET S— BLOCK, T —BLOCK R —BOARD
105 7/06/2005
PR, VR OR RPR
WALL
INSIDE CLOSURE
PANEL RIB (80130)
VEE RIB (8D360)
RPR PANEL (80140)
1/2"
J
BASE
TRIM
(BT-
PR, VR OR RPR W/ BASE TRIM
W00123V5 5/31/200
12 -14 1 1/4"
WALL STRUCT
FSNR.
1' -0" D.C.
WC2421 3/23/2054
E1 XE0 CL TNT A'1
3) 0 YJ 1NS A BANK NS
c o D B W B 8 1AN
1 SV BLO
182 ,N/ 8 *II
TMER Ok-
L X -INC SAG ANGLES (SA-)
(NOT REQD. WITH WIDEBAY
OR JOIST)
CBA1
NOTE. A CONC. FSNR. MUST BE LOCATED
LESS THAN 6" FROM EACH END OF THE
BASE MEMBER.
3/16" 1/4" TAPE MASTIC (80390)
12 -14 1 1/4"
WALL STRUCT FSNR
2 PER FOOT 0 PANEL RIB
1 PER FOOT 0 VR RPR
BASE ANGLE (BAT)
SHOWN. MAY BE
BASE G3),
BASE (CB4)
FINISH FLOOR OR
TOP OF CURB WALL
CONCRETE FASTENER
24" 0.C. (NOT BY V.P.)
BASE OF WALL ATTACHMENT M/CO1A3 PANEL RIB WALL
1 1
DOOR FLASHING
JAMB TRIM AT OVERHEAD DOOR
PANEL RIB WALL
PANEL RIB
UNER
IRC62B11 PURLINS AT INTERIOR FRAME
I I I 6 1/2 OR 8 1/2' SIMPLE PURLINS W/O CLIP
8SO1B224 5/12/2004
BG1 BG2 OR BC3
1
PANEL RIB
WALL PANEL
JAMB TRIM
OT—)
1/4 -14 7/8" WALL STITCH
FSNR. 1 PER SUPPORT
AND 1 PER GIRT SPACE
FSNRS RE0'D WHEN SPACE
EXCEEDS 6-0"
12 -14 1 1/4
WALL STRUCT
FSNR.
2 PER FOOT
12 -14 1 1/4
WALL STRUCT
FSNR.
2 PER FOOT
FASTENER PATTERNS
0004210 3/23/2004
I� I
SECTION A —A
12 -14 1 1/4
WALL STRUCT
FSNR.
1' -O" 0.0
PANEL RIB
WALL PANEL
IWC24A11 WALL TRIM AT DOOR HEAD
I 1 I OVERHEAD DOOR OPENING
05024245 04/06 /2005
ODOR HEADER
THE VP ENGINEER 5 SEAL APPLIES
ONLY TO THE WORK PRODUCT OF
VP AND DESIGN AND PERFORMANCE
REQUIREMENTS SPECIFIED BY VP
THE VP ENGINEER S SEAL DOES
NOT APPLY TO THE PERFORMANCE
OR DESIGN OF ANY OTHER PRODUCT
OR COMPONENT FURNISHED BY VP
EXCEPT TO ANY DESIGN OR PER-
FORMANCE REQUIREMENTS
SPECIFIED BY VP
IRSO1 B21 PURLIN SUPPORT CLIPS
1 1 6 1/2 OR 8 1/2' PURLINS
EAVE OR
RAKE MEMBER
INTERMEDIATE
WALL GIRT
-12-14 1 1/4"
WALL STRUCT
FSNR.
1 PER FOOT
AT INT GIRTS
BASE MEMBER
PANEL SIDELAP
IWCO4A11
I I I
HEADER
TRIM (HTS
12 -14 1 1/4'
WALL STRUCT
FSR.
1' -D O.C.
DOOR. FLASHING
NOTE: ALL BOLTS SHALL BE
1/2" A325 UNLESS NOTED
OTHERWISE
NOTE INTERIOR FRAME
SHOWN, ENDFRAME SIMILAR
PURLIN SUPPORT CLIP (PC27) ARE
REQ'0. AT SSR FIXED CLIP LOCATIONS.
THEY ARE NOT REO'D. AT END FRAMES
OR PURLINS w/ OTHER TYPE CUPS.
REFER TO ERECTION DRAWINGS FOR
ALL PC27 CUP LOCATIONS.
RSO3A1 0/13/2005
1 1/4
ift ill
SECTION A —A
1 1/4
WALL STRUCT
FSNR.
1 0' 0.C.
4043403 3/24/2054
s o'
Acg
SEAL WITH
SKINNING
SEALANT (.°507)
IWC24A2 SILL TRIM
I 1 FRAMED OPENING (PANEL RIB)
5
SEE RS10 *1 FOR
I I I
RAKE C HANNEL
MARK NUMBER
PR, VR OR RPR WALL PANEL
(SEE ERECTION DRAWINGS)
✓r
G
6 1/2' 8 1/2"
PURLINS
RAFTER
72 -14 1 1/4"
WALL STRUCT FSNR
2 PER FOOT 0 .PANEL RIB
1 PER FOOT 0 VEE RIB RPR
PR,VR OR RPR ENDWALL AT RAKE IWC10A11
W/ BLANKET INSULATION 1 1 I
wn tw m /st /z
1 PANEL RIB
WALL PANEL
FIELD MITER
(TY AS
REQ'D.
1/4 -14 7/8"
I WALL STITCH
FSNR.
1' -0" D.C.
DOOR FLASHING
(TOF
12 -14 1 1/4"
WALL STRUCT
FSNR.
WINDOW SILL 1 0' 0.C.
THIS DRAWING INCLUDING THE INFORMATION HEREON
REMA STHE ROP RTY OF VP BUILD
IT IS ROVID SOL FOR ERECTING THE LOING
DES 185 E APPLICABLE PURCHASE ORDER AND
SHALL NOT MOD ED, REPRODUCED OR US D R
NY 0711E RPOS WITHOUT PRIOR WRITTE
PPROVAL OF VP
THE GENERAL CONTR AND/OR ER TOR SSOLELY
RESPONS FOR ACLU ATE, GOOD OU LITY WORKMAN
RECTIN NG IN CONFORMANCE WITH THIS
AWI ILS ENCED NT AWI
AP E VP E TION GUIDES
NDUSTRY RDS PERTAIN ROP
OTON CORR MPORARY
FASTEN RAKE
CHANNEL LAPS
WITH (2)
1/4 -14 1 1/4
STRUCT FSNR
(55307)
ENDWALL
IRSO3A1I RAKE CHANNEL TO PURLIN (SSR) IRS10G11 WELDED LOW EAVE PURLIN IRS11A21
I 1 6 1/2" 8 1/2' OR 11 1/2 PURLIN (PR OR VR WALLS)! 1 1 P B END FRAME (6 1/2 OR 8 1/2' PURLIN) 1 1 I
100121 02/24/0 8511349 0/00/2005
1/2" CLEARANCE
BETWEEN ROOF
AND WALL PANEL
AT OUTSIDE FACE
OF WALL PANEL1
NC1 :05 5/31/2005
FLANGE BRAC
(FB OR
(SFB
WSOIAZY2
2/01/2004
R VI
II
II
I
W. P
12 -14 1 1/4"
WALL STRUCT
FSNR.
2 PER FOOT 0 PANEL RIB
1 PER FOOT 0 VR RPR
ZEE GIRT SHOWN
CEE GIRT SIMILAR
DATE
FACE OF
WALL PANEL
11/9/2005
RAKE CHANNEL
(RKCJ AT 6 1/2" PURUNS
(R (RKC--) AT 8 1/2' PURUNS
KCH_) AT 11 1/2" PURUNS
Id
PR, VR OR RPR
BOLTS
NTS
(1) 1/4 -14 x 1 1/4'
WALL STRUCT FSNR
(55307)
WALL PANEL
PR, VR RPR WALL AT EAVE
STANDARD EAVE PURLIN
1WC24A4 GIRT CONN AT COLUMN
I 1 6 1/2 B 1/2' OUTSET SIMPLE GIRTS
VP Buildings, Inc.
3200 Players Club Circle Memphis TN 38125
BOTTOM OF
ROOF SHEET
t COLUMN
DESCRIPTION
10:21:20
STANDARD EAVE
PURUN
GIRT CLIP (GC4)
MAY BE SHOP
WELDED (001)
BOLTS
BUILDING SED'S
PURUN CUP
(EPC2 0 6 1/2') WELDED
(PC13 0 6 1/2 BOLTED
(EPC3 0 8 1/2") WELDED
(ARC1 W 8 1/2") BOLTED
RAKE BEAM
1/4 -14 7/8"
WALL STITCH
FSNR.
1' -0" O.C.
OUTSIDE CORNER
FLASHING (CT
BUILDER
CHG Building Systems, Inc.
rUSTOMERET Environmental
1LOCATION Port Angeles, Washington
1PROJECT Port Angeles Transfer Station
!BUILDER'S POO 15226
FILENAME CA0501694-010E1 vpc
9
1
6
IWC1 1A11 OUTSIDE CORNER TRIM
1 1 1 PANEL RIB WALL
*520 155 2/21/2005
FRAME
EXPIRES 07 18- aC.
IWSO1A2I
1 1FOR 4PPROVAL NOT FOR CONSTRUCTION
STANDARD LOW
EAVE PURLIN
PANEL
RIB
WALL
IWC20A11
I 1 I
OB
O501694 -01
DATE
CA
10/4/2005
VP BUILDINGS DRAWN/CHECK
V2*02#RIAEN MDS
5.3b PAG =20
FIELD LOCATE AND DRILL
(2) 9/16" DIA. HOLES IN
RAFTER FOR BOLTS
GABLE GIRT CUP
(GC11 0 8 1/2" GIRTS
(GC64 0 6 1/2" GIRTS
OUTSET GIRT
ZEE GIRT SHOWN
CEE GIRT SIMILAR
GABLE GIRT CONN TO RAKE BEAM IWSO4A2 GIRT CONN AT CORNER COLUMN IWS12D2I
6 1/2 8 1/2' OUTSET GIRTS 1 1 ANY OUTSET GIRT AT EW ANY OUTSET GIRT AT SW 1 1 I
*5044208 7/01/2064 85I202Y1 5/25/2004
OF
HOLES
DOOR JAMB
CLIP (DJC1-
OR DJC6
BOTTOM OF
RAKE
BEAM-
JAMB TO RAKE BEAM
8 1/2 OR 6 1/2' JAMB, OUTSET ENDWALL
*5205547 5/27/2204
RAKE BEAM
RAKE
BEAM
FIELD LOCATE AND DRILL (2) 6/18'
OIAMEIER HOLES RAKE BEAN
TO ATTACH (PI01)
8 1/2' OR 6 1/2'
JAMB SINGLE
OR DOUBLE
SECTION A -A
IWS20A5 JAMB BASE ATTACHMENT.
RAKE
BEAM
NOTE; FIELD NOTCH 8 1/2' ENDWALL
GIRT FLANGE WHEN CORNER COLUMN
FLANGE WIDTH EXCEEDS 7'
COLUMN
6 1/2" DR 8 1/2"
ENDWALL
GIRT
CORNER
GIRT CUP
(GCC
1/4 -14 1 1/4"
STRUCT FSNR
(55307)
2 PER ANGLE a'/ RT
6 1/2" OR 8 1/2'
JAMB, SINGLE
OR DOUBLE
FRAMED
OPENING
12 -24 1 1/4"
STRUCT
FSNR (56101)
2 PER JAMB
(ALTERNATE. TACK
1 1 /4
a
I
I a
L
0
6 1/2 OR 8 1/2' JAMB
W520UV5 06/05/2020
GIRT CUP
SEE FRAME SECTION
FOR CLIP MARK /'S
HOLES MAY BE
CENTERD ON
GIRT CUP
6 1/2" OR 8 1/2"
SIDEWALL GIRT
1
GIRT FILLER
ANGLE (GFA
FRAME
JAMB BASE CUP
r CI 0 8 1/2" JAMB
C2 0 6 1/2' JAMB
1/2" ANCHOR
BOLTS
6
AX
THE VP ENGINEER 5 SEAL APPLIES
ONLY TO THE WORK PRODUCT OF
VP AND DESIGN AND PERFORMANCE
REQUIREMENTS SPECIFIED BY VP
THE VP ENGINEER S SEAL DOES
NOT APPLY TO THE PERFORMANCE
OR DESIGN OF ANY OTHER PRODUCT
OR COMPONENT FURNISHED BY VP
EXCEPT TO ANY DESIGN OR PER-
FORMANCE REQUIREMENTS
SPECIFIED BY VP
CONCRETE FSNR
AT 24" 0.C.
(NOT BY V.P
BASE MEMBER
IWS20A8I
I 1 I
FIELD LOCATE AND DRILL (2)
9/16' DIA HOLES IN GIRT FOR
(GC10) OR (GC65) GIRT CUP
6 1/2" OR 8 1/2'
OUTSET EW
GIRT
GIRT CUP
(GC10) OR
(GC65)
SECTION A -A
GIRT CONN AT CORNER COLUMN IWS12E2 JAMB TO GIRT
ANY OUTSET GIRT AT EW 8 1/2' INSET GIRT AT SW 1 1
5512C2V) 05/26/2004
3/4"
3 1/4"
1 1
10 1
1
SECTION A -A
GIRT TO JAMB
8 1/2 GIRT 8 1/2 JAMB
*5200246 R */2A/2005
GIRT FILLER
ANGLE (GFA
1.101E, FIELD NOTCH 8 1/2" ENDWALL
GIRT FLANGE WHEN CORNER COLUMN
FLANGE WIDTH EXCEEDS 7'
yJ
8 1/2" GIRT
ZEE GIRT SHOWN
CEE GIRT SIMILAR
GIRT CLIP (GCS)
MAY BE SHOP
WELDED (GC2)
8 1/2" INSET
SW GIRT
1/4 14 1 1/4'
STRUCT FSNR
(55307)
3 PER ANGLE
O iRT
8 1/2" JAMB,
SINGLE OR
DOUBLE
IWS20D2I
1 I I
THIS DRAWING, INCLUDING THE INFORMATION HEREON
EMAINS THE ROPERTY OF VP BU NGS.
RI ROVIDEDSOLEL GTHE ILDIN
ESCR BED IN THE APPLICABLE RCHASE ORDER AND
SHALL OT BE MODIFIED, REPRODUC D OR USED F
NY OTHER PURPOSE WITHOUT PRIOR WRITTEN
APPROVAL OF VP BUILDINGS
THE ERAL CONTRACT ND/OR IS SOLEL
RESPON LE FOR ACLU ATE, GOOD UA11Y WORKMANS
N CTING THIS BUILD IN CO MAAN WITH THIS
D AWING, DETAILS REFS ENCED NTH1 AWING,
ALL APPLICABLE VP ERECTION GU S
STRY STANDARDS RTAIN GTO ROPER
0110 NCL GTHE COR SE OFTEMPOR
BRAG
6 1/2" OR 8 1/2"
CEE GIRT
8 1/2' F
3/4"
I 5 1/4"
8 1/2" JAMB, ANY CEE GIRT
*5260145 05/27/2004
6 1/2' OR 8 1/2'
DOOR HEADER
b 1/2" OR`
8 1/2
EQUAL 3` EQUAL
r 1 I I ;I
I OPENING
1 HEIGHT
I I
SECTION A -A
HEADER TO JAMB
ANY HEADER, ANY SINGLE JAMB
*5200445 05/27/2004
REV'
II
II
II
1
ATE
11/9/2005
NTS
FIELD LOCATE AND DRILL (2) 9/16'
DIAMETER HOLES IN CEE GIRT
TO ATTACH JAMB
VP Buildings, Inc.
3200 Players Club Circle Memphis TN 38125
00500IO
10:21:22
GIRT
ELEVATION
8 1/2" JAMB,
SINGLE OR
DOUBLE
1/2" OR 8 1/2"
JAMB. SINGLE
IWS20D9I.
I I I
6 1/2" OR 8 1/2"
ZEE GIRT
8 1/2"
3 2 3/4"
3 1/2"
SECTION A -A
IWS20A11 JAMB TO GIRT
I 1 I 8 1/2 JAMB, ANY ZEE GIRT
*5204248 05/27/2004
BUILDING SED'S
BU1100R
I CI-IG Building Systems, Inc.
IGUSTOMER ET Environmental
'10041100 Port Angeles, Washington
'PROJECT Port Angeles Transfer Station
'BUILDER'S PON 15226
FILENAME CA0501694 -01OE1 vpc
FIELD LOCATE AND DRILL (2) 9/16'
D451451 R HOLES IN ZEE GIRT
TO ATTACH JAMB
FOR APPROVAL NOT FOR CONSTRUCTION
A 8 1/2" JAMB,
SINGLE DR
DOUBLE
VPC VERSION 5.3b
GIRT
ELEVATION
IWS20A2I
1 I I
JOBS
CA0501694 -01
DATE
10/4/2005
DRAWNA:HECK
MDS
PAGE 21
STANDARD CLIPS
KEY TO
MARK NUMBERS
REFER TO
EN50A1
GGC1'_
GIRT CONN. CUP
(OUTSET)
JAMB TO COL.
EIGHTHS CONN. PLATE
T� FS
(ucHNS
T M IN HET
JC_
STANDARD TRIM
*TRIM COLOR NOTE*
D DESIGNATES COLOR SIDE
-PITCH CODE TO 12
GUTTER CLOSURE
12
1 1/4"
VARIES
d
M
RCL_
�NOM. LENGTH
RAKE CLOSURE
12
PITCH CODE
TO 12
GC11*
GGC_
RCL
DOOR JAMB CLIP
(OUTSET)
GIRT CONN. CUP
(INSET)
PS8
`LEIGHTHS
INCHES
FEET
AT_
NOM. LENGTH
ADAPTOR TRIM
C
HT_
f- NOM. LENGTH
HEADER TRIM I HT_
1 22 5/8 1/2
h
.I
1
RKF
`NOM. LENGTH
RAKE FASCIA
DJC1
12
PITCH CODE
TO 12
10012 PURLIN CONN, CUP
PURLIN STABILITY
BRACE
LENGTH
PSB_
4" -1
AT
1 1/4"
4
1
1/2"
RKCF_
DDO( CLIP I D J C 2*
0
0
BASE TRIM
1 7/B"
SOFFIT EAVE FLASH
GC1 6
1 a
BT__
NOM. LENGTH i`4'
IBT
HTS "i4 1/2'
NOM. LENGTH
HEADER TRIM
HIS
I 5 1
SET=
-PRCH CODE TO
NOM. LENGTH
OUTSET GIRT
CORNER CLIP GCC072084
'4
C
CET*
PITCH CODE
TD 12
NOM. LENGTH I 4
CANOPY EAVE TRIM 0ET_
H1
INSIDE CORNER
TRIM
ICF___
NOM. LENGTH
FFC
T 3/4°
PITCH CODE
TO 12
ENDPOST
CLIP
(FULL
FRAME)
CF
SET=
12 T L--- PRCH CODE TO 12
NOM. LENGTH
S E F SOFFIT EAVE TRIM S ET_
THE VP ENGINEER 5 SEAL APPLIES
ONLY TO THE WORK PRODUCT OF
VP AND DESIGN AND PERFORMANCE
REQUIREMENTS SPECIFIED BY VP
THE VP ENGINEER 5 SEAL DOES
NOT APPLY TO THE PERFORMANCE
OR DESIGN OF ANY OTHER PRODUCT
DR COMPONENT FURNISHED BY VP
EXCEPT TO ANY DESIGN OR PER-
FORMANCE REQUIREMENTS
SPECIFIED BY VP
GCC072
OUTSET GIRT
CUP
�FIDHTLS
TH'K (EIGHTHS)
N (INCHES)
pNCnrs
1 004
CORNER TRIM
1 1/4
Jf
NOM. LENGTH
JAMB TRIM
N C
ST__
Fes �1
NOM. LENGTH
SOFFIT TRIM
NOM. LENGTH
I CT_
I JT_
ST_
INSET GIRT
CUP
OUTSET GIRT
CORNER CLIP (GEN.) GCD05___
GCC Lg m6�IN 63
MASONRY TRIM
1005
GCD
N1i
DF__
NOM. LENGTH
DOOR FLASHING D F
8 5/8"
1
MS n
Y— NOM. LENGTH
MS
I I---DIMENSIONAL CODE
NOMINAL LENGTH
goo EXT.) STC_
GCE05
7
L—
THIS DRAWING INCLUDING THE INFORMATION HEREON
MAINS THE ROPERTY OF VP LDINGS
RI PROVIDEDSOLEL ERE G'ME
DESCRIBED IN A LICABLE PU HASE AND
HALL NOT BE MODIFIED, R PRO C D OR US OR
NY OTHER PURPOSE WITHOUT RIOR WRNTE
ROVAL OF VP BUILD 805.
THE GENERAL CONTRA0 ND/OR CTOR IS 501EL
SPONSIBLE FOR ACCU GOOD WITTY WORKMAN
ERECTING THI5 U CONFOR MAN EWITH THIS
AWI G. DETA RE EN DRAWI
LAP LICABLE ER TION
ND NDUSTRY AND RCS TAM GTOP
ERECTION INC RIG THE COR CT 5E OF TEMPOR
BRAG NG.
INSET GIRT
CUP
EItiNNS
711'1
1. (Eldrtn5))
WON (NCNES)
L/R HAND
PITCH CODE-
I
100
TO 12 I EA
EAVE ASSEMBLY
Q
MTV
NOM. LENGTH
MASONRY EAVE TRIM T
3"
7LT_
NOM. LENGTH
TUF -CITE TRIM
GCE_
INSET
GIRT
CLIP
PARTS TO BE
SHOP
ASSEMBLED
(LEFT HAND
SHOWN)
1 1 1
I T LT_
REV
DATE
11/11/2005
INSET GIRT
CUP
GIRT FILLER
ANGLE
GCB
GFA -1
CFA_ LENGTH =1 -6"
[-f CADS L GFA_
58 \L 1
2 9/16'
1 7/1611
3/4"
1 1/4
I -PRCH CODE- TO 12
NOM. LENGTH I E F
SAVE FASCIA
12 t Y7 1 1/2"
,i
3
1 1/4
1I�
1
4 1/
4 I/2'
PKF_5 Ll
-PITCH CODE- TO 12
NOM. LENGTH
PEAK FASCIA I P F_
WALL TO ROOF
FLASHING
12
VARIES
VP Buildings, Inc.
3200 Players Club Circle Memphis TN 38125
DESCRIPTION
a
WRF=
I I-- PITCH CODE- TO 12
NOM. LENGTH
WRF
10:51
CORNER COL. CONN.
TO RAKE CHANNEL I G C 9
GIRT CONN. CUP
TO EAVE PURUN
EG
VARIES
I GP C1
PRCH CO DE- TO 12
NOM. LENGTH
EAVE GUTTER E G
MRD19 Drawing
BUILDER
CHG Building Systems, Inc.
ICUSTOMERET Environmental
IILGCATION Port Angeles, Washington
IPROJECT Port Angeles Transfer Station
1E16110E6'S POR 15226
81105AME. CA0501694 -010E1 vpc
OUTSET GIRT CUP
(FULL FRAME)
JAMB BASE CUP
1
Er—
r -PITCH CODE- TO 12
NOM. LENGTH
EAVE TRIM
12
GC 1 0*
IJBC
B 3/^
I ET_
n
PITCH CODE
_TO 12
DIM A
RCF__ 11
I DIMENSIONAL CODE
NOMINAL LENGTH
ROOF HEIGHT R C F_
C6 T IIIPA5II NG
1) w I/4
WAS 4.
G
VPC VERS 5.3b
OBs
CA0501694 -01
DATE
I 10/4/2005
I I DRAWN/CHECK
MDS
I PAGE 22
TYP
SEE NOTE 4
HAUNCH COLUMN CONNECTION
TOP BOLTED
SEE NOTE 4
l
FRAME CONNECTION
INTERIOR COLUMN
SEE NOTE 4
TYP V
1 DESIGN MEMBER DEPTH
(SEE FRAME CROSS SECTION
V
**v
I
�ST1FF
3
V
N
DESIGN MEMBER DEPTH
TYPICAL BASE PLATE CONNECTION
BASE PLATE TO COLUMN
V STITCH
1 1/2 3 (10 GA WEB 14 WEB
2 5 4 8 (5/16 1/2 WEB
(S.W.)
11/2"
DENOTES 2%
1 .11 7 BASE PLATE
1 I
I/STITCH
1 1/2" 3 (10 GA. WEB)
2 5 3/16 1/4 WEB)
4 8 5/16 1/2 WEB =--1-
I I
1 1 I
COLUMN (CX OR (ICX
MAY BE STRAIGHT
SEE NOTE 4
V
D
4* V STITCH
1 1/2 3 (10 GA WEB)
2 5 (3/16 1/4 WEB)
4 8 (5/16 1/2 WEB)
I LOW SIDE HAUNCH CONNECTION
FACE BOLTED
SEE NOTE 4
DENOTES 214
VSTITCH
1 1/2" 3 (10 GA. WEB)
HIGH SIDE CONNECTION
FACE BOLTED
SEE NOTE 4
V
THE VP ENGINEER 5 SEAL APPLIES
ONLY TO THE WORK PRODUCT OF
VP AND DESIGN AND PERFORMANCE
REQUIREMENTS SPECIFIED BY VP
THE VP ENGINEER S SEAL DOES
NOT APPLY TO THE PERFORMANCE
OR DESIGN OF ANY OTHER PRODUCT
OR COMPONENT FURNISHED BY VP
EXCEPT TO ANY DESIGN OR PER-
FORMANCE REQUIREMENTS
SPECIFIED BY VP
1
1
ROWS
t I
N.1 7
N
DESIGN MEMBER DEPTH
N
TUBE OR PIPE BASE PLATE CONNECTI
BASE PLATE TO COLUMN y
ROWS
IN
EXPIRES
ROWS
OUT A
0
**7
V \TYP
1 V
BEAM MAY BE
2 5 (3/16 1/4 WEB) TAPERED
4 8 (5/16 1/2 WEB) DESIGN MEMBER DEPTH
DENOTES 2)7
1
COLUMN (CX OR (ICX
TUBE OR PIPE COLUMN
RANDOM SHOP SPLICE
BASE PLATE
rtT I
07 18- 41.ko
1
SEE NOTE 4
N
TYP
TYP
I RIDGE CONNECTION
I I I BOLTED
I FLANGE CHANGE CONNECTION
1 1 1 SPUCE
FLANGE PLATE
WEB PLATE
V MIN.
ROWS
OUT
FI 3 RIMS
FFFiii
---L
GENERAL NOTES.
DENOTES 21"
3 BOLTS AT 3" GUAGE TYPICAL.
4 SIZE OF WELDS UNLESS NOTED ARE
BASED ON MATERIAL THICKNESS AND A.W.S.
STANDARDS
I I
I I I
1 SEE FRAME CROSS SECTION FOR BOLTING
PLATE THICKNESS AND NUMBER OF ROWS
OUT AND N.
2. MIN. BOLTING PLATE WIDTH FLANGE SIZE
(6" MIN.)
FLANGE THICKNESS
3/16" 1/4" 1 5/16 "1 3/8 1 1/2" 1 5/8" 1 3/4" 1 1" 11 1/8 "11 1/4 "I>1 1/4'
3/16 1 3/16" 3/16" 1 3/16"
b/16 061 1/8" 1/8" 1 1/8" I 1/8" 1/B" I 1/8" 1 3/16"
1/4" 1 1/8" 1/8"
5/16" 1 1/8" 1/8"
Lr 3/8 "1 1/8 1 1/8
1/2" 1 1 /8" 1 1 /8"
3I 5/8" 1 1 /8" I 1/8
3/4" 13/16" 13/16"
1 /8" 1 1/8"
3/16" 1 3/16"
3/16" 1 3/16"
3/16" 13/16"
3/16" 1 3/16"
3/16" 1 3/16"
TYPICAL NOTES
TYPICAL SECTION THRU BUILT -UP MEMBERS
THIS DRAWING INCLUDING THE INFORMATION HEREON
REMAINS THE RTY OF VP LOIN
R IS PROMO SOLELY FOR G THE BUILDIN
DESCR BED N THE APPLICABLE CHASE ORDER AND
SHALL NOT BE MODIFIED, REPRO C D OR USED FO
ANY OTHER P RPOSE WITHOUT P IOR WRITTEN
APPROVAL OF VP BUILDINGS.
THE GENERAL CONTRACTOR AND/OR ERECTOR OLEL
RESPONSIBLE FOR ACCURATE. GOOD QUALITY WORKMAN
N ERECTING THIS BU LOIN N CONFORMANCE WITH THIS
DRAWING. DETAILS REFEREN N THI DRAWIN
ALL AP LICABLE VP ERECTO
ND INDUSTRY STANDARDS TNN T PROPER
ER TION. UDING THE COR SE OF TEMPORARY
BR NG.
1/8" 1 1/8" 1 3/16"
3/16" 1 3/16" 1 3/16"
3/16" 1 3/16" 1 3/16"
3/16" 1 3/16" 1 3/16"
3/16" I 1/4" 11/4
3/16 I 1/4" 1 1/4"
1 3/16" 1 1/4"
13/16" 1 1/4"
13/16" 1 1/4"
13/16" 1 1/4"
1 1/4" 1 1/4"
1 1 /4" 1 1
VP Buildings, Inc.
3200 Players Club Circle Memphis TN 38125
REV(
II
1/4" 1 1/4"
1/4" 1 5/16"
1/4" 1 5/16"
1/4 1 5/16
1/4" 1 5/16
1/4" 1 5/16"
I I
I I I
11/11/2005
BV
NTS
1
DENOTES 2'34"
I SPLICE CONNECTION
I I I
TYP
UP TO 1/4 MAT
RANDOM SHOP SPLICE
SHOP SPUCE
n
V I
i \L
I y
ROWS
OUT
LIGHT GUAGE WELDS
SHAPES PRODUCED FROM DOUBLE CEE LIGHT GUAGE MATERIALS SHALL BE JOINED
BY INTERMITTENT GROOVE WELDS DOWN BOTH SIDES OF THE MEMBER. THE WELDS
NT SHALL BE 2" LONG AND LOCATED NO FURTHER APART FROM THE SPACING
SHOWN IN THE TABLE. IN ADDITION TD THE REQUIRED INTERMITTENT WELDS THE
FIRST 2" AT EACH END OF THE MEMBER SHALL BE JOINED BY 2" OF WELD.
24' 1 4-8
TYP J TABLE
TYP 2
LIGHT GAGE WELDS
DESCRIPTION
10:5113
SPACING TABLE
MEMBER MAX. SPACING
LENGTH I OF 2" WELD
6' 1 L6 6
Z 6' 12' 12"
Z 12' 18'1 24"
18' 241 36"
FOR APPROVAL NOT FOR CONSTRUCTION
MRD50 Drawing
z
\TYP
X ROWS
IN
(BUILDER CHG Building Systems, Inc.
rUSTOMERET Environmental
I LDD511ON Port Angeles, Washington
r 0.IECT Port Angeles Transfer Station
BUILDERS POs 15226
FILENAME CA0501694-01 OE 1.vpc
BEAM MAY BE
TAPERED
Z o
0
OB
CA0501694 -01
J I DATE
10/4/2005
VP BUILDINGS DRAWNICHEGK
ARCOFRL 5 MDS
PAGE 23
VPC VERSION 5.3b
ROOF STRUCTURAL FASTENER
12 -14 X 1 1/4' SS SCOTS (TEKS /2) WITH WASHER
MARK
NUMBER COLOR
57407 ARTIC WHITE
57403 ASH GRAY
57406 CLASSIC BEIGE
57415 COOL COLONIAL RED
57416 COOL DARK BRONZE
57417 COOL REGAL WHITE
57418 COOL SIERRA TAN
57419 COOL WEATHERED COOPER
57420 COOL ZINC GREY
57401 EGYPTIAN WHITE
ROOF STRUCTURAL FASTENER
12 -14 X 1 1/2' SS SCOTS (TEKS /2) WITH WASHER
MARK MARK
NUMBER COLOR NUMBER
57807
57803
57806
57815
57816
57817
57818
57819
57820
57801
ROOF STITCH FASTENER
1/4 -14 X 7/8' SS SCOTS (TEKS /1) WITH WASHER
MARK MARK
NUMBER COLOR NUMBER
57607
57603
57606
57615
57617
57618
57601
ROOF STITCH FASTENER
1/4-14 X 1 1/8' SS SCOTS (TEKS /1) WITH WASHER
MARK MARK
NUMBER COLOR NUMBER
57657
57653
57656
57665
57666
57667
57668
57669
57670
57651
ARTIC WHITE
ASH GRAY
CLASSIC BEIGE
COOL COLONIAL RED
COOL DARK BRONZE
COOL REGAL WHITE
COOL SIERRA TAN
COOL WEATHERED COOPER
COOL ZINC GREY
EGYPTIAN WHITE
ARTIC WHITE
ASH GRAY
CLASSIC BEIGE
COOL COLONIAL RED
COOL REGAL WHITE
COOL SIERRA TAN
EGYPTIAN WHITE
ARTIC WHITE
ASH GRAY
CLASSIC BEIGE
COOL COLONIAL RED
COOL DARK BRONZE
COOL REGAL WHITE
COOL SIERRA TAN
COOL WEATHERED COOPER
COOL ZINC GREY
EGYPTIAN WHITE
MARK
NUMBER
57421
57426
57427
59462
57422
57409
57423
57424
57425
59464
57400
57821
57826
57827
57812
57822
57809
57823
57824
57825
57814
57800
57612
57609
57623
57624
57625
57614
57600
57671
57676
57677
59402
57672
57659
57673
57674
57675
59404
57650
COLOR
FOREST GREEN
HEMLOCK GREEN
JADE GREEN
LEAF GREEN
MATTE BLACK
PATRICIAN BRONZE
REGAL BLUE
TAHOE BLUE
TERRA COTTA
ZINC GRAY
GALVALUME
COLOR
FOREST GREEN
HEMLOCK GREEN
JADE GREEN
LEAF GREEN
MATTE BLACK
PATRICIAN BRONZE
REGAL BLUE
TAHOE BLUE
TERRA COTTA
ZINC GRAY
GALVALUME
COLOR
LEAF GREEN
PATRICIAN BRONZE
REGAL BLUE
TAHOE BLUE
TERRA COTTA
ZINC GRAY
GALVALUME
COLOR
FOREST GREEN
HEMLOCK GREEN
JADE GREEN
LEAF GREEN
MATTE BLACK
PATRICIAN BRONZE
REGAL BLUE
TAHOE BLUE
TERRA COTTA
ZINC GRAY
GALVALUME
THE VP ENGINEER S SEAL APPLIES
ONLY TO THE WORK PRODUCT OF
VP AND DESIGN AND PERFORMANCE
REQUIREMENTS SPECIFIED BY VP
THE VP ENGINEER 5 SEAL DOES
NOT APPLY TO THE PERFORMANCE
OR DESIGN OF ANY OTHER PRODUCT
OR COMPONENT FURNISHED BY VP
EXCEPT TO ANY DESIGN OR PER-
FORMANCE REQUIREMENTS
SPECIFIED BY VP
WALL STRUCTURAL FASTENER
12 -14 X 1 1/4' CARBON (TEKS /2) W/O WASHER
MARK
NUMBER COLOR
56467 ARTIC WHITE
56463 ASH GRAY
56466 CLASSIC BEIGE
56475 COOL COLONIAL RED
56476 COOL DARK BRONZE
56477 COOL REGAL WHITE
56478 COOL SIERRA TAN
56479 COOL WEATHERED COOPER
56480 COOL ZINC GREY
56451 EGYPTIAN WHITE
WALL STRUCTURAL FASTENER
12 -14 X 1 1/2' CARBON (TEKS /2) W/O WASHER
MARK
NUMBER COLOR
56667 ARTIC WHITE
56663 ASH GRAY
56666 CLASSIC BEIGE
56675 COOL COLONIAL RED
56676 COOL DARK BRONZE
56677 COOL REGAL WHITE
56678 COOL SIERRA TAN
56679 COOL WEATHERED COOPER
56680 COOL ZINC GREY
56651 EGYPTIAN WHITE
WALL STITCH FASTENER
1/4 -14 X 7/8' CARBON (TEKS /1) W/O WASHER
MARK
NUMBER COLOR
56567 ARTIC WHITE
56563 ASH GRAY
56566 CLASSIC BEIGE
56575 COOL COLONIAL RED
56576 COOL DARK BRONZE
56577 COOL REGAL WHITE
56578 COOL SIERRA TAN
56579 COOL WEATHERED COOPER
56580 COOL ZINC GREY
56551 EGYPTIAN WHITE
MARK
NUMBER
56481
56486
56487
56471
56482
56459
56483
56484
56485
56473
56461
MARK
NUMBER
56681
56686
56687
56671
56682
56659
56683
56684
56685
56673
56661
MARK
NUMBER
56581
56586
56587
56971
56582
56559
56583
56584
56585
56573
56561
COLOR
FOREST GREEN
HEMLOCK GREEN
JADE GREEN
LEAF GREEN
MATTE BLACK
PATRICIAN BRONZE
REGAL BLUE
TAHOE BLUE
TERRA COTTA
ZINC GRAY
GALVALUME
COLOR
FOREST GREEN
HEMLOCK GREEN
JADE GREEN
LEAF GREEN
MATTE BLACK
PATRICIAN BRONZE
REGAL BLUE
TAHOE BLUE
TERRA COTTA
ZINC GRAY
GALVALUME
COLOR
FOREST GREEN
HEMLOCK GREEN
JADE GREEN
LEAF GREEN
MATTE BLACK
PATRICIAN BRONZE
REGAL BLUE
TAHOE BLUE
TERRA COTTA
ZINC GRAY
GALVALUME
THIS DRAWING. INCLUDING THE INFORMATION HEREON,
REMAINS THE PROPERTY OF VP LDIN
IT 5 ROVID D5OLEL FOR ER CTING THE ILD
((SCR BED N THE APPLICABLE PURCHASE DER AND
SH LL NOTE OD ED. REPRO C DOR USED FOR
ANY OTHER RPOS WITHOUT 100 WRITTEN
APPROVAL OF VP BUILDINGS
TH ERAL CONTRACTOR ND/OR ERECTO OLEL
RESPON LE FOR ACCURATE. GOOD 0 LITY WORKMAN
CTINGTHIS DU LOIN N CONFORMANCE WDH TH15
RAWING DETAIL REFEREN IN THIS DRAWIN
LL APPLICABLE V ERECTION IDES
O STR TANDARDS PERTAIN PROPER
ER CTIO DING THE CORREC SE FTEMPORARY
VP Buildings, Inc.
3200 Players Club Circle Memphis TN 38125
IREVI
1 I
DATE
11/11/2005
PANEL CLOSURES
MARK
NUMBER
80130
80140
80360
80362
80356
80358
80140
80130
80135
80136
POP RIVETS
1/8' DIAMETER ALUMINUM RIVET (250 PER BOX)
MARK
NUMBER COLOR
55261 ARTIC WHITE
55267 ASH GRAY
55262 CLASSIC BEIGE
55269 COOL COLONIAL RED
55286 COOL DARK BRONZE
55287 COOL REGAL WHITE
55288 COOL SIERRA TAN
55289 COOL WEATHERED COOPER
55290 COOL ZINC GREY-
55260 EGYPTIAN WHITE
BULB TITE STRUCTURAL BLIND RIVET
MARK
NUMBER COLOR
55181 ARTIC WHITE
55160 ALUMINUM
TUBE SEALANT
MARK
NUMBER DESCRIPTION
80260 WHITE SKINNING
80265 GRAY SKINNING
TAPE MASTIC
DESCRIPTION
3' INSIDE PANEL RIB CLOSURE
3' OUTSIDE PANEL RIB CLOSURE
3' INSIDE VEE RIB CLOSURE
3' OUTSIDE VEE RIB CLOSURE
16' INSIDE STRAN -LOK CLOSURE
16' OUTSIDE STRAN -LOK CLOSURE
3' INSIDE RPR PANEL CLOSURE
3' OUTSIDE RPR PANEL CLOSURE
SSR FOAM INSIDE CLOSURE
SSR HARD RUBBER INSIDE CLOSURE
MARK
NUMBER DESCRIPTION
80069
80335
80345
I
I I
I 1
NTS
DESCRIPTION
10:51012
MARK
NUMBER
55291
55296
55297
55283
55292
55265
55293
55294
55295
55285
MARK
NUMBER
55185
MARK
NUMBER
80270
80507
3/16' X 2' X 25' ROLL
3/16' X 2 1/2' X 20' ROLL
3/16' X 7/8' X 28' BOX OF 100
200 LINEAL FEET OF COVERAGE PER BOX
80347 3/16' X 7/8' X 9' (50) AND 3' (150) BOX
100 LINEAR FEET OF COVERAGE PER BOX
80349 3/16' X 7/8' X 40' ROLL
80390 3/16' X 1/4' X 40' ROLL
BUILDER
CI-IG Building Systems, Inc.
IcusEOMERET Environmental
1100An0N Port Angeles, Washington
(PROJECT Port Angeles Transfer Station
(BUILDERS POU 15226
FILENAME CA0501694 -01OE1 vpc
COLOR
FOREST GREEN
HEMLOCK GREEN
JADE GREEN
LEAF GREEN
MATTE BLACK
PATRICIAN BRONZE
REGAL BLUE
TAHOE BLUE
TERRA COTTA
ZINC GRAY
COLOR
PATRICIAN BRONZE
DESCRIPTION
WHITE NON SKINNING
BRONZE SKINNING
EXPIRES 07 18- c
FOR APPROVAL NOT FOR CONSTRUCTION
Common Warehouse Partmarks
OB
CA0501694 -01
J DATE
10/4/2005
VP BUILDINGS DRAWN/CHECK MDS
VPCVE 5.3b PA0024
1
Application Number . . . . . 22-00000632 Date 5/24/22
Application pin number . . . 700552
Property Address . . . . . . 3501 BLDG D W 18TH ST
ASSESSOR PARCEL NUMBER: 07-30-01-2-2-0000-0000-
Application type description ELECTRICAL ONLY
Subdivision Name . . . . . .
Property Use . . . . . . . .
Property Zoning . . . . . . . UNKNOWN
Application valuation . . . . 0
----------------------------------------------------------------------------
Application desc
Outlet scale read out
----------------------------------------------------------------------------
Owner Contractor
------------------------ ------------------------
CITY OF PORT ANGELES OLYMPIC ELECTRIC CO INC
321 E 5TH ST 4230 TUMWATER
PORT ANGELES WA 983620217 PORT ANGELES WA 98363
(360) 457-5303
----------------------------------------------------------------------------
Permit . . . . . . ELECTRICAL ALTER COMMERCIAL
Additional desc . .
Permit Fee . . . . 74.00 Plan Check Fee . . .00
Issue Date . . . . 5/24/22 Valuation . . . . 0
Expiration Date . . 11/20/22
Qty Unit Charge Per Extension
1.00 74.0000 ECH EL-COMM BRANCH CIR WO/ S/F 74.00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 74.00 74.00 .00 .00
Plan Check Total .00 .00 .00 .00
Grand Total 74.00 74.00 .00 .00
ELECTRICAL INSPECTION WIRING REPORT
APPROVED NOT APPROVED
DITCH
ROUGH IN/COVER
SERVICE
FINAL
COMMENTS:
Scale outlet
NOTIFY INSPECTOR at (360) 808-2613
WHEN CORRECTIONS ARE COMPLETED
WITHIN 15 DAYS
DATE PERMIT # INSPECTOR
5/24/2022 22-632 TAP
OWNER
CONTRACTOR
Olympic Electric
PROJECT ADDRESS
3501 W 18th St