HomeMy WebLinkAbout2127 W 12th St Technical - BuildingLO
1
JV3IXII3-LL
(Customer Service
(Servicio al cliente)
1- 800 -437 -0784
1000 Ternes Drive
Monroe, MI 48162
Tools required
(Herramientas
necesarias)
Hammer
(Martillo)
Phillips
Screwdriver
(Desarmador cruz)
Level
(Nivel)
0 Ladder
(Escalera)
0 Pencil
(Lapiz)
0 Tape Measure
(Cinta metrica)
0 Utility Knife
(Navaja)
Paint Tools
(Herramientas
para pintar)
Caulk Gun
(Pistola para
masillado)
Hand Saw
(Sierra portatil)
0 Wood Glue
(Pegamento para
madera)
Includ (366x366 cm), .1 2'x16' (366x488;c),
12 036 6 CM, ,1 2 24 (366x732 c o a,?
305x61
InVAL!cclo
066x488 m
Optional Tools
(Herramientas
opcionales)
Electric Drill w/
#2 Phillips Tip
(Taladro electrico
Broca 'Phillips')
Chalk Line
(Linea de marcar)
0 Square
(Escuadra)
Nail Pouch
(Bolsillo para
clavos)
First.
Heritage Premier Series
12' Wide Gable
Techo a dos :aguas 1
Check with your local building authority before erecting.
Read instructions thoroughly before you begin.
Building Codes
Our buildings are designed to meet most local and national
U.S. codes and are not meant to be used for living space.
General construction drawings can be provided.
Stamped certified drawings can be provided for a fee.
I Call for details.
Check All Parts
If a part is missing, circle the part in question and call.
Please note the primer color may vary on siding and
trim parts. This is a factory applied primer intended for
preparing your building for painting. This is NOT a finish
coat. This primer color variation will not affect the look of
your building once painted.
Important
Lumber is graded from one side, use most attractive
face to the outside.
In a drawing, a dotted line represents a part hidden from
view (like a part under a panel).
Assistance required
Assistance is necessary to handle, fit, and secure
some components.
Squareness is very Important!
Keep 90° corners and 90° perpendiculars throughout
the assembly to ensure all components fit together
Check foundation size
Before starting on your foundation, make sure you are
building the correct size foundation for your building.
Always wear OSHA APPROVED safety
glasses throughout assembly process
Base +3
Extenders/
Extensiones
12'x24'
(366x732 cm)
Base +2
Extenders/
Extensiones
12'x20'
(366x610 cm)
We ma ufactu kits from elect stmctla grade lumbe nd ngi eered wood products Co str ctio grade
lumbe product ut from tr ha many atu al cha actensti nd blemishe that may be pr nt ome of
the pi s yo c n yo kit. Nato at cha acte stic nd blemishe str ctio lumbe may nclude knots
tom wood gra along edge mi r cks /splits twists limited bark along edge nd pitch pockets that may
ude ap. Be u ad that the ndiwdual parts have be cut nd apected to remo e many of the wood'
atu al, les appealing cha cte sti pos able Thes cha acte sti and/o blemishe will not affect the
str ngth, du ability, or str eta at me my of the to shed product. Gen ally, the elite trim parts selected far
yo kit e graded from only ide and should be nstalled with the most attractiv ide utward. Ou limited
wa r my do of the atu at charade stir nd blemishe that with struck grade lumbe
products
i
Base +1
Extenders/
Extensiones
12'x16'
(366x488 cm)
Consulte la autoridad de construccion local antes de
construir el edificio.
Lea las instrucciones completamente antes de empezar
Codigos de Construction
Hemos disenado nuestros edificios a que conformen con
todos los cbdigos de construccion locales y nacionales. Los
edificios no estan proyectados como residencia.
Se disponen planes generales de construccion.
Se disponen de planes certificados por un precio. Estos
l planes no garantizan la aprobacion de los autoridades
ocales.
Compruebe todas las piezas
Si falta una pieza, indicala con un circulo y Ilamenos.
Aviso' El color del imprimador puede varier en la covertura
y las partes de la moldura. Este imprimador se aplica en la
fabrica y es para preparar su edificio para pintar NO es una
capa de pintura terminada. La variation en el color del
imprimador no afectara la apariencia de su edificio al pintarlo.
Importante
La Madera esta elaborada en un solo lado. Use el /ado mas
atractivo en el exterior
Si falta una pieza, pongale un circulo y Ilamenos.
En un dibujo una linea punteada representa una pieza no
vista (por ejemplo, una pieza debajo de un panel)
Ayuda requerido
Seleccione un sitio nivelado.
Sera necesario pedir ayuda para manejar unir y reforzar
algunas piezas.
iEs precise escuadrar el edificio!
Manfenga angulos de 90° en las esquinas y los
perpendiculares durante la construccion para asegurar que
todas las piezas se unen correctamente.
C.om rueba las dimensiones de la
cimentacion
Compruebe que las dimensiones de la cimentacion son las
correctas para el edificio.
Siempre Ileve gates de seguridad
aprobadas por HA dura la
construccion.
I #16608 I 02/08/20071
Made in the USA
Hecho en Estados Unidos
Base
Building /Edificios
12'x12'
(366x366 cm)
Fabr amo estr egwpos de made elabo ado y de producto maqu ado de made La made
elabo ada producto de Arbole tie mucha ca cterlsbca Imperfec e aturale qu pueda
to algu a pi s etc idas el equlpo Este impede y cterlsti puede Mehl!'
udo gr sgado obr el horde ajas /gr eta pequefia to s n orte el borde y boll
qu ude a Asegu ams qu hemo ortado e Inspe ado la parte ndi iduale pa a ohm!
las acterish aturale men s atr ctiva po ible Estes acterlstic y/o impel
afectarin la fue du abilidad la ntegndad structural del producto final. Po to ge al, las pi de
moldu xte ele ada par equipo s elabor de n olo lade y deben statada
la parte mAs atractiv por fue Nu stra gar ntla limitada ubr la ctertstic impete
que urre to producto de made a elabo ada
0
w
I
0
0
c
-J
N
N
W
—J
m
CD
J
12' x 12' (366 x 366 cm)
PARTS LIST
8 "x84" 3/8 "x15- 7 /8 "x84"
i
12' X 12' (366 x 366 cm)
LISTA DE PIEZAS
WO
1 'x4 'x72 3/8'
(2.5x10x184 cm)
WP x4
1 'x4'x72'
(2.5x10x183 cm)
x1
YD
1 'x4 'x83 -5/8'
(2.5x10x212 cm)
1 'x4'x63 -1 /4
(2.5x10x161 cm)
YB
x4 YMX
x4 HM
1 'x4 'x68-3/8'
(2.5x10x174 cm)
1'x3 "x84
(2.5x10x213cm)
x4
End Caps
x4 T
El Fin Tapa
x4
3/8 "x4
(.9x122x213 cm)
(.9x40x213 cm)
3/8 "x11 7/8 "x32"
(9x30x82 cm)
2x6x92 1/2"
(5x15x235 cm)
UN
UY
Rafter
UW
x9 B
2x4x94 -1/2"
(5x10x240 cm)
2x4X6 -1 /2"
(5x10x17 cm)
x7
7/16 "x48 "x96'
(1 1x122x244cm)
3/8 "x23- 9/16 "x48'
(9x61x122 cm)
x2 UL
2x4x48"
(5x10x61 cm)
SP
x2 c
2x4x92 5/8"
(5x10x235 cm)
Viga Gusset
x14
x10 UM
7/16 "x47 7/8 "x48'
(1 1x122x122cm)
3/8 "x23- 7 /8 "x84"
(.9x61x213 cm)
x8 TK
2x4x68'
(5x10x173 cm)
3/8 "x33 -1 /2 "x48' 3/8 "x23- 9/16 "x48'
(.9x85x122 cm) (9x61x122 cm)
X2 D
2x4x80"
(5x10x203 cm)
x2W
7/16 "x32 "x96'
(1 1 x81 x244cm)
x2 G -1
Placa de union
x27 VF
2x6x67'
(5x15x171 cm)
x12 KP
3/8 "x2 "x3 -11 /16'
(.9x5x10cm)
X2 VK
2x6x48"
(5x15x122 cm)
3/8 "x5 "x33"
(.9x13x84 cm)
x2 F -1
1 x4x96'
(153 cm)
7/16 "x31 7/8 "x48'
(1 1 x81 x122cm)
2 "x4 'x19 -3/16'
(5x10x49 cm)
c
Z x4 CaM
x2
x2
x2
x5
2
2 "x4 "x68 -1 /2'
(5x10x174 cm)
Puerta
izquierda
Right
Door
1 'x4'x35 -1/4
(2.5x10x91 cm)
x2 WGL
Puerta
derecha
68 -1/2" Weatherstrip
(174 cm)
x1 DWS
1 'x4'x35 -1 /4
(2.5x10x91 cm)
x1 DEL
x2WGR x2
68 -1/2" Metal Door Edge 'L"
(174 cm)
1 'x4 'x14
(2.5x10x36 cm)
x4
12' X 12' (366 x 366 cm)
PARTS LIST
i
12' X 12' (366 x 366 cm)
LISTA DE PIEZAS
1
1/4' (3cm)
x2
i
x2
x1
1 (2.5cm) �GG GGGGGGCGGCkCG x2
OX-C.F V-V -UV —C4-4 x2
NOTE
Double and Triple letter part identification
letters are stamped on parts and read
horizontally single letter part designations
are not stamped
Lumber Sizes
(Dimension nominal)
1x4
2x4
2x6
Actual Size Dimensiones verdaderas
3' (7 6 cm)
2' (5 0 cm)
2' (5 0 cm)
1 1/2' (38cm)
3' (7 6 cm)
2'(41 cm)
1 5/8' (4 1 cm) CO
1 (2.5 cm)
1 (2.5 cm)
RS RS
3
F
�r�'.C- �FC�C:XFG.G�FG�Gw
7rGatkGt muGLC-vgauFGECLCw4
r rGGGGGG -m-v4 G:cauG u
CGGr�GCC����G
x206
x695
x230
x188
GG s4. x18
x12
x10
x59
GGGGGtr_vg C -t_mx= x34
AVISO
Dos letras o tres letras de identificacion
estan marcadas horizontalmente en las
piezas. Letras de identificacion de una sola
letra no estan en las piezas.
Dimensiones de la madera
Dimensiones verdaderas)
3/4 x 3 -1/2' (1 9 x 8 9 cm)
1 -1/2' x3 -1/2' (3 8x8 9cm)
1-1/2' x 5-1/2' (3 8 x 14 cm)
3/8"x48"x84 3/8"x23-7/8"x84 2x6x48' 2x4x80' 2x4x48'
(.9x122x214 cm) (.9x61x214 cm) (5x17x122 cm) (203 cm) (122 cm)
X1 C
7/16"x32"x96'
(1 1x81x244cm)
3/4 'x3-1/2"x48'
(1 9x8.9x122 cm)
x2 Fl
Rafter
VF x2 TK x4 SP
7/16"x31 7/8"x48'
(1 1x81x122cnn)
Viga Gusset
1x4x96'
(244 cm)
x2
Placa de Union
0
0
0
a
0
Ui
LL
12' X 4' (366 x 122 cm) I 12' X 4' (366 x 122 cm)
LISTA DE PIEZAS DE EXTENSION
EXTENDER PARTS LIST
Actual Size
1
1 3' (7 6 cm)
4
Dimensiones verdaderas
1
2' (5 0 cm)
1 1/2' (3.8 cm)
x 214
x 12
IMPORTANT!!! IMPORTANTE!!!
Building Tip Consejo
FOR THE BEST LOOKING FINISHED PRODUCT WE
RECOMMEND THAT YOU INSPECT, SORT AND LAY
OUT MATERIALS PRIORTO BEGINNING
ASSEMBLY OF YOUR BUILDING
HELPFUL MATERIAL NOTICE I AVISO UTIL SOBRE LOS MATERIALES
B
Wood is a natural product that has inherent blemishes. All
interior framing is graded for structural strength and not
appearance. Exterior trim is graded for one good side per
industry standards.
Blemishes can be easily installed to provide the best
appearance. (Fig. A)
Install wall framing with any blemished sides toward the
siding and facing rear of building. (Fig. B)
Install corner trim, gable trim and fascia with any blemished
sides toward the siding material. (Fig. C)
Always install the material leaving the best edge and best
surface visible.
Please remember that these blemishes in no way negatively
affect the strength or integrity of our product.
Please feel free to call our Consumer Help Line Toll Free
1- 800-437 -0784
Monday through Friday
8:00 AM to 5:00 PM EST
Saturday (March through October)
10:00 AM to 4:00 PM EST
A
5
CON EL FIN DE OBTENER EL PRODUCTO
ACABADO DE MEJOR ASPECTO
RECOMENDAMOS QUE INSPECCIONE,
CLASIFIQUEY ORGANICE LOS MATERIALES
ANTES DE EMPEZAR A MONTAR SU EDIFICIO
C
NMI MIN
La madera es un producto natural que tiene defectos
inherentes. Todo la estructura interior ha sido aprobada por
ofrecer una resistencia estructural y no por su aspecto. La
guarnicion exterior ha sido aprobada por tener un buen lado
segun las normas de la industria.
La parte con defectos puede instalarse facilmente de modo
que el edificio tenga el mejor aspecto. (Fig. A)
Instale el entramado de la pared con los lados con defectos
apuntando hacia los costados y haciendo frente a la parte
trasera del edificio. (Fig. B)
Instale la guarnicion de las esquinas, la guarnicion de
los hastiales y las impostas con los lados con
defectos apuntando hacia el material lateral. (Fig. C)
Instale siempre el material dejando visibles el mejor borde y la
mejor superficie.
Recuerde que estos defectos no afectan de forma negativa la
resistencia o la integridad de nuestros productos.
Llame de forma gratuita a nuestra linea de ayuda al
consumidor
1-800-437-0784
Lunes a viernes
8:00 AM a 5:00 PM, hora estandar del este
Sabado (marzo a octubre)
10:00 AM a 4:00 PM, hora estandar del este
FOUNDATION OPTIONS
(Not supplied with kit)
YOU MUST ASSEMBLE YOUR BUILDING ON A
WOOD FLOOR OR CONCRETE SLAB.
OPCIONES PARA LA CIMENTACION
(No incluidas)
HAY QUE CONSTRUIR EL EDIFICIO SOBRE UN BASE
DE MADERA 0 DE CONCRETO.
SITE PREPARATION
Site must be properly leveled
Site should have natural drainage
and no standing water
A) Purchase our optional Floor Kit or
build your own wood floor.
A) Compre nuestro equipo opcional para el
suelo o construya su propio suelo de madera.
Building Size
Dimensiones del edificio A B
12' x 12' (366 x 366 cm) 144' (366 cm)1144' (366 cm)
12' x 16' (366 x 488 cm) 144' (366 cm)1192' (488 cm)
12' x 20' (366 x 610 cm) 144 (366 cm)1240' (610 cm)
12' x 24' (366 x 732 cm) 144' (366 cm)1288' (732 cm)
Important: Square floor and level to ground
before beginning assembly of building.
B) Concrete Slab Foundation I B) Base en Iosa de concreto
Treated Sill
Soleras Inferiors Tratadas
Building Size
Dimensiones del edificio A B C
12' x 12' (366 x 366 cm)1144' (366 cm)1137' (348 cm)1144' (366 cm)
12' x 16' (366 x 488 cm)1144' (366 cm)1185' (470 cm)1192' (488 cm)
12' x 20' (366 x 610 cm)1144' (366 cm)1233' (592 cm)1240' (610 cm)
12' x 24' (366 x 732 cm)1144' (366 cm)1281 (714 cm)1288' (732 cm)
Fasten treated 2x4 sill plates to slab using approved
concrete anchors. (Treated sill plates and fasteners not
included.)
6
PREPARACION DEL SITIO
El sitio debe de estar nivelado correctamente.
Instale una barrera contra yerbajos debajo de la
estructura.
Importante• Asegure que el suelo esta nivelado y
escuadrado antes de construir el edificio.
4
(10 cm)
Fije las soleras inferiores tratadas 2x4 a la Iosa con anclajes
de concreto aprobados. (Las soleras y los anclajes no estan
incluidos.)
Before proceeding, determine
desired door location and
build door wall first.
Antes de continuar determine Ia
posicion de Ia puerta y
construya el muro con Ia puerta
primero.
BUILD WALL NUMBERS SPECIFIED
WALL NUMBER EQUALS PAGE NUMBER
CONSTRUYA LOS NUMEROS DE LOS
MUROS ESPECIFICADOS
EL NUMERO DEL MURO CORRESPONDE
AL NUMERO DE LA PAGINA.
IMPORTANT!!! IMPORTANTE!!!
Building Tip Consejo
YOUR BUILDING CAN BE CONFIGURED IN A
VARIETY OF WAYS. BEFORE ERECTING WALLS,
REFER TO PAGE 5 TO ENSURE YOU BUILT THE
RIGHT WALLS FOR YOUR BUILDING.
Erecting the Walls
I Construyendo los Muros
Make sure all walls are built as shown below
BUILD DOOR WALL FIRST
3 -1/2'
(8.9 cm)
3 -1/2'
(8.9 cm)
Inside of Wall
Interior del muro
24' 24 24'
(61 cm) (61 cm) x(61 cm)~
3 -1/2'
h cm)
9
ES PRECISO ALINEAR LOS PANELES DE LOS
MUROS Y DEL TECHO ANTES DE CLAVARLOS
COMPLETAMENTE PARA ASEGURAR LA
ESCUADRA.
Asegure que se construyan los muros como
en los dibujos abajo
CONSTRUYA EL MURO CON PUERTA
PRIMERO
Flush
1 Nivelado
3 -1/2' -►I k–
(8.9 cm)
2' (5 cm) Nail /Clavo
12' (30 cm)
1
(2.5 cm)-
3 -1/2'
(8.9 cm)
2' (5 cm) Nail /Clavo
IMPORTANT!!! I IMPORTANTE!!!
Building Tip Consejo
YOU MAY NEED TO RACK YOUR WALL PANELS
AND ROOF PANELS TO ENSURE SQUARENESS
BEFORE COMPLETELY NAILING
ES PRECISO ALINEAR LOS PANELES DE LOS
MUROS Y DEL TECHO ANTES DE CLAVARLOS
COMPLETAMENTE PARA ASEGURAR LA
ESCUADRA.
Racking a Wall
I Alineando un Muro
Flush
Nivelado A
Nail
Clavo
Top Corner Should Be Flush
La esquina superior debe
estar nivelado con la
estructura
When building walls, always apply panel at far left first. Position
panel flush with top of wall frame and nail in upper corners as shown.
Rack wall square by moving lower end of wall panel right or left until
panel is flush with framing along left edge and secure with one nail in
each lower corner Continue nailing as instructed.
Rack for Squareness
Nivele para escuadrar
Position panel flush with outside front edge of rafter and nail in two corners
as shown. Rack panel square by moving opposite end up or down until panel
is flush along peak of rafters and secure with one nail in each corner.
Ensure spacing of center rafters and nail as instructed.
10
Flush
Nivelado
Al construir los muros, siempre fije primero el panel hasta Ia izquierda
extrema. Posicione el panel nivelado con la parte superior de Ia
estructura del muro y clavelo en la esquina superior como en el dibujo.
Alinee nivelado el muro por mover el lado inferior a la derecha o a Ia
izquierda hasta que el panel este nivelado con Ia estructura a to largo
del borde izquierda. Fije con un clavo en cada esquina inferior.
Racking a Roof
Alineando un techo
Flush
Nivelado
Nail
Clavo
B
Flush with Rafter Peak
Nivelado con Ia parte mas
alta de las vigas
Posicione los paneles nivelados con el borde delantero exterior de la viga y slave
en las dos esquinas como en el dibujo. Alines escuadra el panel por mover los
extremos opuestos arriba o abajo hasta que el panel este nivelado a to largo del
punto mas alto de las vigas, y fijelo con un clavo en cada esquina. Compruebe el
espacio de las vigas centrales y slave como indicado.
HEADER
UY x7
3"(7.6 cm)
64
x 28
STOP! DO NOT BUILD DOOR FRAMING AT THIS POINT
USE AS A REFERENCE ONLY
9-1/2' 24 24 9-1/2'
(24cm) H (61cm) (61cm) (24cm)
T TT T T .1 1 T TT
1 1
TT T ,T T Q)
(163cm)
Header
11
80'
(204cm)
E x2
WALL #15
3 "(7.6 cm) x 34 M U RO #15
2"(5 cm) x 135
REPEAT FOR
ALL SPLICES
Overhead View
f
ISP x21
83"
(211cm)
6' L.
(15 cm)
12'
(31 cm)
H
Flush
1 V
24" H" 24' 24"
(61cm) (61cm) (61cm)
I.I I.I
48"
(122cm)
IULx2
I
I.I I.I I.I I.I
A
II I II III II fl II III
144'
(366cm)
15
24" I— 24' 20- 1/2
(61cm) (61cm) (52cm)
92 -1/2'
(235cm)
ITK x7 I
140 -1/2"
/(357cm)
SP
11111 Id 11111
ITK x121
UY x7
83"
(211cm)
1sP 1
I
48'
(122cm)
Flush
6' _L
(15 cm)
t
H
9-1/2" 24" 24" 9-1/2"
III IT
r(24cm)I (61cm) I (61cm) I(24cm)
IHEADERI
ISP1
—1
16" 64"
(41cm) (163cm)
1
48'
(122cm)
16"
(41cm)
HI I I
[Bs
6' _L
(15 cm)
7
If
—1
24' I 24' 24" 24' 24"
(61cm) (61cm) (61cm) (61cm) (61cm) (61cm) (52cm)
I I
48'
(122cm)
1 s P 1
12'
(31 cm)
I I III I
48' 92-1/2'
(122cm) (235cm)
A
i _L___
12' 12'
(31 cm) (31 cm)
24" I-20-1/2"H
II I
I 1 I I I I I I I I I I I III II II II II
288'
(732cm)
I REPEAT FOR
I ALL SPLICES
284-1/2"
/(723cm)
H).
1110,
REPEAT FOR
ALL SPLICES
Overhead Mew
83"
(211cm)
48"
48°
1.1
48"
1.I 1.I
48"
92-1/2"
(122cm) (122cm) (122cm) (122cm) (235cm)
Flush
6'L.
(15 cm)
12'
(31 cm)
I— 24" —I— 24" I 24" H 24 I 24 H 24" I 24 1 24' H— 24' 24" —I— 24' 1 20-1/2 I
(61cm) (61cm) (61cm) (61cm) (61cm) (61cm) (61cm) (61cm) (61cm) (61cm) (61cm) (52cm)
SP x1:11
A A A A A
288"
(732cm)
I III II II II II
UL x2 1
ITIC x131
284-1/2"
/(723cm)
ERECTING
WALLS
See Page 9 For Building Tip!!!
ERECT SOLID WALLS FIRST
CON6TRUYA LOS MUROS
SOLIDOS PRIMERO
See Page 7-8 for wall
Ver Ia pagina 7-8 para muro.
ERECTING
WALLS
See Page 9 For Building Tip!!!
See Page 7-8 for wall
Ver la pagina 7-8 para muro.
Level Wall and Nail
Nivele la pared y
clave.
3' (7.6 cm) x 12 (12'x12') (366 x 366 cm)
16 (12'x16') (366 x 488 cm)
x 16 (12'x12') (366 x 366 cm) x 20 (12'x20') (366 x 610 cm)
x 20 (10'x12') (366 x 488 cm) n 2"(5 cm x 24 (12'x24') (366 x 732 cm)
x 24 (10'x16') (366 x 610 cm)
x 28 (12'x24') (366 x 732 cm)
3' (7.6 cm) x 17
2' (5 cm) x 18
28
3"
(7.6 cm)
IVer Ia pagina 9 para un consejo!!!
Level Wall and Brace, Do not
sink nails completely
Nivele la pared y refuerzala.
No hinque los clavos
completamente.
CONSTRUYENDO
LOS MUROS
iVer Ia pagina 9 para un consejo!!!
CONSTRUYENDO
LOS MUROS
ERECTING
WALLS
x 22 (12'x12') (366 x 366 cm)
x 28 (12'x16') (366 x 488 cm)
x 34 (12'x20') (366 x 610 cm)
x 40 (12'x24') (366 x 732 cm)
See Page 9 For Building Tip!!!
See Page 7-8 for wall
Ver la pagina 7-8 para muro.
17 (30 cm)
ERECTING
WALLS
After walls are erected, make sure X to X
and Y to Y measurements are the same
Level Wall and Nail
Nivele la pared y clave
2' (5 cm) x 22
3"(7.6 cm)
12" (30 cm)
2"
(5 cm),
12"
(30 cm)
X
2"(5 cm)
29
x 21 (12'x12') (366 x 366 cm)
x 27 (12'x16') (366 x 488 cm)
x 33 (12'x20') (366 x 610 cm)
x 39 (12'x24') (366 x 732 cm)
IVer la pagina 9 para un consejo!!!
CONSTRUYENDO
LOS MUROS
Despues de construir los muros, asegurese
que las medidas 'X a X' y 'Y a Y' son iguales.
Y
12" (30 cm)
Do Not NO In Door Opening
No clave en la abertura de
puerta.
CONSTRUYENDO
LOS MUROS
See Page 7-8 for wall
Remove
Quite
Ver la pagina 7-8 para muro.
(5 cm)
t
17 (30 cm)
DOUBLERS
12 x 12' (366 x 366 cm)
TOP VIEW
148"
(376 cm)
TOP VIEW
148
(376 cm)
12' x 20' (366 x 610 cm)
3 "(7.6 cm)
30
12' x 16' (366 x 488 cm
x 66 (12'x12') (366x366cm)
x 78 (12'x16') (366x488cm)
x 90 (12'x20') (366x610cm)
x 102(12'x24') (366x732cm)
vF TOP VIEW
148"
(376 cm)
I 2,241143617 x
r ISP
VF
T VK
VF
VF
TOP VIEW
VF
VK
148"
DOBLADORES
ISP
VF
End Rafter Assembly x2
Flush/
Nivelado
2' (5 cm)
Nails /Clavos
UW x2
Middle Rafter Assembly
(See sizes below for quantity)
UW x2
Red Ends
Terminos rojos
Glue
Pegamento
1
1 1/2 "(3.8 cm)
x 12
148'
(376 cm)
N~
N
KP Qx2
31
ti
Q
2 "(5 cm)
148'
(376 cm)
x8
Cry s�'
1 -1/2' (3.8 cm)
Nails Clavos
TECHO
Conjunto de vigas terminals x2
Flush
Nivelado
Conjunto de vigas centrales
(Ver las dimensiones abajo
para la cantidad)
Flush
Nivelado
Q x2
X2
COLLAR TIES ARE NOT
TO BE USED FOR HANGING,
STORAGE OR AS LOFT
SUPPORTS
MID RAFTERS NEEDED PER BUILDING SIZE
12'x12' (366 x 366 cm) x5 12'x20' (366 x 610 cm) x9
12'x16' (366 x 488 cm) x7 12'x24' (366 x 732 cm) x11
Attaching Rafters and Soffit Blocks
(See below for dimensions)
12'x12' (366 x 366 cm)
12'x16' (366 x 488 cm)
12'x20' (366 x 610 cm)
12'x24' (366 x 732 cm)
3 "(7 6 cm) x42
I— 24° 24' d— 24" 24" 4- 24" -4- 24" i
(61cm) (61cm) (61cm) (61cm) (61cm) (61cm)
I
H 24' 24' 24" H 24' I 24" -I- 24' 4 24" 4 24" H
(61cm) (61cm) (61cm) (61cm) (61cm) (61cm) (61cm) (61cm)
l l
I— 24" 24" —I- 24" 24" —I— 24' H— 24" 24" —H 24" —I— 24" —I- 24° —I
(61cm) (61cm) (61cm) (61cm) (61cm) (61cm) (61cm) (61cm) (61cm) (61cm)
1
32
Flush
Nivelado
12x12 x42
12x16 x54
12x20 x66
12x24 x78
Fijando las vigas y los bloques del sofito.
(Ver abajo para las dimensiones.)
Flush
Nivelado
3
3' (7.6 cm) x 42
Repeat step on
each rafter
Repetir el paso en
cada viga
3' (7.6 cm) x 54
3' (7.6 cm) x 66
IH 24" ~I- 24" 4— 24' -I- 24' 24" 24" 24" 24' 4- 24" 24" 4- 24" 24"
(61cm) (61cm) (61cm) (61cm) (61cm) (61cm) (61cm) (61cm) (61cm) (61cm) (61cm) (61cm)
3' (76cm)
See Page 10 For Building Tip!!!
F1
G
F -1
F1
I GI
12'x12' (366 x 366 cm)
F1
F -1
12'x16' (366 x 488 cm)
G
F -1
12'x20' (366 x 610 cm) Shown Indicado
G
G -1
F
F1
G
F -1
G -1
F
F
F1
2 "(5 cm)
12'x24' (366 x 732 cm) Shown Indicado
REPEAT ROOF PANEL LAYOUT FOR BOTH SIDES OF ROOF
REPEAT ROOF PANEL LAYOUT FOR BOTH SIDES OF ROOF
REPEAT ROOF PANEL LAYOUT FOR BOTH SIDES OF ROOF
REPEAT ROOF PANEL LAYOUT FOR BOTH SIDES OF ROOF
33
G
G -1
G1
IGi
I GI
IVer la pagina 10 para un consejo!!!
IGI
F1
x80
x110
x140
x170
Gable Panels
Dry fit assembly on front and
back of building to determine
best alignment of grooves
QM
DRY FIT PANELS AS SHOWN HERE BEFORE ASSEMBLING
Los paneles montan segun to visto
Groove Groove Groove
Surco Surco Surco
1 112'
(3.8 cm)
R
1 1/2" (3.8 cm)
x 92
6 1 -3/4' (4 4 cm)
(15
L.
34
—.I L- 3 -1/2' (8.9 cm)
Paneles del techo a dos agues
Compruebe Ia alineacian del
surco en frente y Ia parte
posteriora
12x12 (366x366cm) Shown
12x16 (366x488cm)
x174
WP x2
2"(5 cm) 3/4"(1.9 cm)
m amtugUtp.
x150 x6
WJ x2
YMX
WJ x2
12x20 (366x610cm
WP x2
WP x2
x186
35
12x24 (366x732cm)
WJ x2
WJ x2
WJ x2
WP x2
x198
WP x2
3/8� (9cm)
Top
1- 5/8 "(41 cm)
x8
7/16' (1 1cm) 3/8' (9c
U e
Supe
I
DOOR PUERTA
1
36
HM
W
Place a center mark for door location
Ponga un senal en el centro para la puerta
Cut out bottom plate at door opening
Leave treated sill on concrete slab if
desired
Corte la placa inferior en la abertura de
la puerta. Deje la solera tratada en la
losa de concreto si quiere
A V-
B [2
MVFF-CCIttCFGFFFFFF- MC-T-MttU FTFFV-' V-MV-GP- 3' (7.6 cm) x 6
w.,.. 2' (5 cm) x 8 C p CFFFFFCFFGFFGCGFw (X 2
(2.5 cm)
A
B
B
*-I 12' (30 cm)
N YD
i 1 i i i i
HM
Do not sink nails completely
No hinque los clavos completamente.
x4
x4
1
Flush
Nivelado
2 "(5 cm)
x 72
Position trim against
underside
Posicione la moldura
contra la parte inferior
H`
YD
37
J
Attach with 3' (7.6 cm) Screws first, check
doors to open properly and nail
Fije con tomillos de 3' (7.6 cm) primero, compruebe que
las puertas abren bien y clave.
Inside Building
Interior del edificio
X
A1�
PUERTA
Remove after doors are screwed
Quite despues de fijar la puerta con
tornillos.
YD
YD
M x 4
WGR x2
WGL x 2
Plain
contemporary Double X
Diamond Traditional X
1"(2.5 cm)
r
x24
38
Outer Diamond Inner Diamond
WO
Existing Door
Puerta Existepte
UP x2
Inside View
Vision Interior
1 '(2.5 cm)
x 23
Exterior Trim
Exterior Moldura
ti
UPx2
Top View: Attaching Door Stiffiner
Vision De arriba: Atadura del apoyo de la puerta
T �2 screw
Outside Al afire libre
Inside Dentro
39
1
2 "(5 cm)
x 20
2 "(2.5 cm)
12
Center vertically on Door
Centro verticalmente en puert:
a
DEL
NOTE Install hook and
eye into trim or stud
0 x2
1"(2.5 cm)
x 34
Flush
Nivelado
40
S
DWS
DEL
HOOK AND EYE AND BARREL BOLT
x2
Drill hole 1/2' (1.3 cm) deep
using 3/8" (.95 cm) bit
Inside of Door/
Interior de la
puerta
1314'
(4, 501
35 1
(89cn
1 12 ('1 2crn)
41
I
PAINT AND CAULK PINTURAY MASILLADO
(Not Included)
(No Incluidas)
Use Acrylic Latex Caulk that is paintable. Caulk at all
horizontal and vertical seams, between the Trim and
Walls, and all around the Door Trim.
Use a high quality exterior acrylic latex paint. When
painting your building, there are a few key areas that can
be easily overlooked that must be painted:
Bottom edge of all siding and trim
Inside of doors and all 4 edges
Note: Prime all un -primed exterior wood before painting
Building Size Building Paint Trim Paint
'Jimensiones del edificio Pintura del edificioPintura de moldura
12' x 12' (366 x 366 cm)I
12' x 16' (366 x 488 cm)I
12' x 20' (366 x 610 cm){
12' x 24' (366 x 732 cm)I
DRIP EDGE
(Not Included)
GOTERO DE BORDE
(No Incluidas)
Close up of drip edge
Vista del gotero
Building Size Drip edge
Dimensiones del edificio Gotero de borde
12' x 12' (366 x 366 cm)
12' x 16' (366 x 488 cm) I
12' x 20' (366 x 610 cm) I
12' x 24' (366 x 732 cm) I
2 1/2 Gallons/
aalones
3 Gallons/
aalones
3 -1/2 Gallons/
galones
4 Gallons/
galones
60 feet/pies
70 feet /pies
70 feet/pies
80 feet/pies
1Quart/cuartas I
1 Quart/cuartas
1 Quart/cuartas
1 Quart/cuartas
Side that hangs over
side No Nails
La parte que esta
colgada sobre un lado
No clavar
Caulk
Masillado
3 Tubes/Tubos
3 Tubes/Tubos
4 Tubes/Tubos
4 Tubes/Tubos
42
Use un masillado acrilico de latex que se puede pintar
Masille todas las junturas horizontales y verticales, entre Ia
moldura y los muros, y alrededor de la moldura de la
puerta.
Use una pintura acrilica de latex de alta calidad. Al pintar
su edificio hay unas areas claves que hay que pintar
El borde inferior de toda Ia covertura y Ia moldura.
El interior de la puerta y todos los 4 bordes de esta.
Aviso Ponga un imprimador en la madera exterior que no
to tiene antes de pintar
Snip bottom side of drip edge and
Bend over to other side of Roof
Corte la parte inferior del gotero y
dbblela sobre el otro lado del techo
SHINGLES
(Not Included)
Building Size Shingles Needed
Dimensiones del edificio Teias Necesarias
12' x 12' (366 x 366 cm)I 6 Bundles /bultos
12' x 16' (366 x 488 cm)I 8 Bundles /bultos
12' x 20' (366 x 610 cm)I10 Bundles /bultos
12' x 24' (366 x 732 cm)I12 Bundles /bultos
Install first row backwards
lnstale la primera fila al reves
Line up notch on top of Shingle with
edge of Roof to stagger the Shingles
Alinee el corte encima de la teja con el
borde del techo para escalonar las
tejas.
Maintain same dimension across
Mantenga la misma dimension
de un lado al otro
Flush to edge, stagger each row
Nivele al borde, escalone cada fila
Remove overhanging shingles
Quite tejas sobresalientes
Flush to dripedge
Nivelado al gotero
d
-e
d
43
NAILS
clavos
I
I 1 I 11 1 1 I I I I
sO
I I r i
Okay if Shingle Overlaps
Este bien si la teja
sobresale
I I I F
I
I
I
1
1
MI i 111111111111111111
I -I MI
a
SHINGLES
(Not Included)
TEJAS
(No Incluidas)
Ridge Cap
Cut Shingles into 3 pieces
Corte las tejas en tres partes
Apply pieces to ridge as shown
Fije las piezas a la cumbrera
como en el dibujo
Check for protruding nails, pound any protruding
nails into the wood or cut them off flush.
Inspeccione para clavos sobresalientes; hinque clavos
sobresalientes en Ia madera or cortelos nivelados con
Ia madera.
To
44
•s ft
Tapa de cumbrera
s
0
NAIL INSPECTION
INSPECCION DE CLAVOS
REQUIRED MAINTENANCE
MANTENIMENTO NECESARIO
Keep grass trimmed and away from building
Corte y quite la hierba cerca del edificio
Keep Sprinklers away from building
No use rociadores cerca del edificio
Repaint building as needed and in accordance
with paint manufacturer requirements
Pinte el edificio de nuevo cada dos anos