HomeMy WebLinkAbout228 Juniper Ln Technical - BuildingTECHNICAL
Permit
Address
01 -S0
Project description Je,w S,no
v J
Date the permit was finaled 05 -23 -08
Number of technical pages
0
geSioteXloe
f
p
PREPARED BY
Client
Project
Location
Date
Calculation By
Comment
Suntel Design
Tigard, Oregon
SUNTEL HOME DESIGN
YAMHILL -R
16' OH DOOR BM 1
10 -17 -2000
L M
R1
Reaction R1 6,905 0 lbs
Total load 14,200 0 lbs
Dimensions Clear span
Point loads P1
P2
P3
No triangular loads
Uniform beam weight=
Uniform loads U2
U1
Deflection limit (live
Actual Maximum Deflection
Maximum Deflection occurs
Maximum Moment occurs
Size Factor 0 976
B E A M A N A L Y S I S
BEAM AND LOAD DIAGRAM
P2
4
4
16 0 feet, no overhang
840 0 lbs
840 0 lbs
840 0 lbs
Reaction R2 7,295 0 lbs
30 lbs /if 480 lbs total)
300 0 lbs /lf at 6 0 feet to 14 0 feet
550 0 lbs /if at 0 0 feet to 16 0 feet
load plus dead load) 1/360
BEAM TYPE LAM 24 F GLULAN
COMPUTED STF?ES.S /STRAIN DESIGN VAL PROPERTIES REQUIRED ACTUAL
Shear (lbs) 7,295 0 FV 165 0 Area (Sq In
Moment (ft-lbs 29,360 0 FB 2,400 0 Sect Modulus
Deflection (in) 0 53 E 1 80E6 Mom Inertia
0 53 inches
at 8 0 feet
at 8 0 feet
P3
y
6
R2
at 2 0 feet
at 6 0 feet
at 14 0 feet
66
150
1,404
DETERMINING FACTOR
MINIMUM BEAM SIZE (W x H) 5 125" by 14 870"
MINIMUM BEAM AREA (Sq In 76 21
76
189
1,404*
Roof Beam! 2000 International Building Code (97 NOS)1 Ver 6.00.8
By Jim Mei Surrtel Home Design on: 11-04 -2005 09:50 :39 AM
a Project: ¥AMHILL R Location: Beam Nr 2 Ridge beam bonus
Summary
6 75 IN x 24.0 IN x 30.0 FT 24F -V4 Visually Graded Western Species Dry Use
Section Adequate By 77.8% Controlling Factor Moment of Inertia Depth Required 19.82 In
Deflections:
Dead Load: DLD=
Live Load: LLD=
Total Load: TLD=
Reactions (Each End):
Live Load: LL -Rxn=
Dead Load: DL -Rxn=
Total Load: TL -Rxn=
Bearing Length Required (Beam only support capacity not checked) EL=
Camber Regd. C=
Beam Data:
Span: L=
Maximum Unbraced Span: Lu=
Pitch Of Roof' RP=
Live Load Deflect. Criteria: U
Total Load Deflect. Criteria: U
Camber Adjustment Factor CAF=
Roof Loading:
Roof Live Load -Side One: LL1=
Roof Dead Load -Side One: DL1=
Tributary Width -Side One: TW1=
Roof Live Load -Side Two: LL2=
Roof Dead Load -Side Two: DL2=
Tributary Width -Side Two: TW2=
Roof Duration Factor Cd=
Beam Self Weight: BSW=
Slope /Pitch Adjusted Lengths and Loads:
Adjusted Beam Length: tacit=
Beam Uniform Live Load wL=
Beam Uniform Dead Load: wD_adi=
Total Uniform Load: wT=
Properties For' 24F -V4- Visually Graded Western Species
Bending Stress: Fb=
Shear Stress: Fv=
Modulus of Elasticity Ex=
Ey=
Stress Perpendicular to Grain: Fc perp=
Bending Stress of Comp Face in Tension: Fb_cpr=
Adjusted Properties
Fb' (Tension): Fb'=
Adjustment Factors. Cd =1 15 CI =1 00 Cv =0.88
Fit' Fit=
Adjustment Factors: Cd -1 15
Design Requirements:
Controlling Moment:
15.0 ft from left support
Critical moment created by combining all dead and live loads.
Controlling Shear
At a distance d from support.
Critical shear created by combining all dead and live loads.
Comparisons With Required Sections:
Section Modulus (Moment)
Area (Shear)
Moment of Inertia (Deflection):
0.29 IN
0.28 IN L/1301
0.56 IN L/639
3188 LB
3300 LB
6488 LB
1 48 IN
0.43 IN
30 0 FT
2.0 FT
9 12
480
360
1.5 X DLD
25.0 PSF
17.0 PSF
50 FT
25.0 PSF
17 0 PSF
3.5 FT
1 15
39 PLF
30 0 FT
213 PLF
220 PLF
433 PLF
2 400 PS
190 PS
1800000 PS
1600000 PS
650 PS
1200 PS
2417 PS
219 PS
M= 48656 FT -LB
V= 5709 LB
Sreq= 241.53 N3
S= 64.8.00 N3
Areq= 39.19 N2
A= 162 00 N2
Irea= 4378.36 N4
1= 7778 00 N4
Roof Beam( 2000 International Building Code (97 NDS) Ver 6.00.8
By Jim Mei Suntel Home Design on: 11 -04 -2005
4 Project: YAMHILL R Location. Beam Nr 2 Ridge beam bonus
Summary
6.75 IN x 24.0 IN x 30.0 FT 24F -V4 Visually Graded Western Species Dry Use
Section Adequate By: 77.6% Controlling Factor Moment of Inertia Depth Required 19,82 In
LOADING DIAGRAM
A
Reactions
Live Load Dead Load Total Load Uplift Load
A 3188 Lb 3300 Lb 6488 Lb 0 Lb
B 3188 Lb 3300 Lb 6488 Lb 0 Lb
Span
Uniform Loading
Live Lopd Dead Loa¢ Self Weight Total Load
W 212 Plf 181 Plf 39 Plf 432 Plf
Span 30 ft
Combination Roof and Floor Beam( 2000 international Building Code (97 NDS) I Ver 6.00.8
By Jim Mei Suntel Home Design on: 11- 04-2005 09:50:42 AM
Protect: YAMHILL llZ Location: Beam Nr 4 at nook
4 Summary
5 125 IN x 12.0 IN x 10.0 FT 124F V4 Visually Graded Western Species Dry Use
Section Adequate By 66.9% Controlling Factor Area Depth Required 9.25 In
Deflections:
Dead Load: DLD= 0.09
Live Load: LLD= 0 14
Total Load: TLD= 0.23
Reactions (Each End):
Live Load: LL -Rxn= -4088
Dead Load: DL -Rxn= 2622
Total Load: TL -Rxn= 6710
Bearing Length Required (Beam only support capacity not checked): BL= 2.01
Camber Regd. G= 0 13
Beam Data:
Span: L= 10.0
Maximum Unbraced Span: Lu= 1.33
Live Load Deflect. Criteria: L/ 360
Total Load Deflect. Criteria: U 240
Camber Adjustment Factor CAF= 1.5
Roof Loading:
Roof Live Load -Side One: RLL1= 25.0
Roof Dead Load -Side One: RDL1= 17.0
Roof Tributary Width -Side One: RTW1= 12.0
Roof Live Load -Side Two. RLL2= 25.0
Roof Dead Load -Side Two: RDL2= 17 0
Roof Tributary Width -Side Two: RTW2= 1.5
Roof Duration Factor Cd -roof= 1 15
Floor Loading:
Floor Live Load -Side One: FLL1= 40 0 PSF
Floor Dead Load -Side One: FDL1= 15.0 PSF
Floor Tributary Width -Side One: FTW1= 11 0 FT
Floor Live Load -Side Two: FLL2= 40.0 PSF
Floor Dead Load -Side Two: FDL2= 15 0 PSF
Floor Tributary Width -Side Two: FTW2= 1 0 FT
Floor Duration Factor Cd -floor= 1 00
Wall Load: WALL= 100 PLF
Beam Loads:
Roof Uniform Live Load: wL- roof`— 338 PLF
Roof Uniform Dead Load (Adjusted for roof pitch)' wD -roof= 230 PLF
Floor Uniform Live Load: wL -floor 480 PLF
Floor Uniform Dead Load: w0-floor— 180 PLF
Beam Self Weight: BSW= 15 PLF
Combined Uniform Live Load: wL= 818 PLF
Combined Uniform Dead Load: wD= 524 PLF
Combined Uniform Total Load: wT= 1342 PLF
Controlling Total Design Load: wT-cont= 1342 PLF
Properties For 24F -V4- Visually Graded Western Species
Bending Stress: Fb= 2400 PS
Shear Stress: Fv= 190 PS
Modulus of Elasticity' Ex= 1800000 PS
4
y
Stress Perpendicular to Grain:
Bending Stress of Comp. Face in Tension:
Adjusted Properties
Fb' (Tension)
Adjustment Factors Cd =1 15 C1 =1.00
Fv'
Adjustment Factors: Cd =1 15
Design Requirements:
Controlling Moment:
5.0 ft from left support
Critical moment created by combining all dead and live loads,
Controlling Shear
At a distance d from support.
Critical shear created by combining all dead and live loads.
Comparisons With Required Sections:
Section Modulus (Moment):
Area (Shear)
Moment of Inertia (Deflection)
Ey= 1600000 PS
Fc perp= 650 PS
Fb_cpr= 1200 PS
Fb'= 2755 PS
IN
IN U867
IN L/528
LB
LB
LB
IN
IN
FT
FT
X OLD
PSF
PSF
FT
PSF
PSF
FT
Fv'= 219 PS
M= 16774 FT -LB
V= 5368 LB
Sreq= 73.08
S= 123.00
Areq= 36.85
A= 61.50
[req.= 335.43
1= 738.00
N3
N3
N2
N2
N4
N4
Combination Roof and Floor Beam[ 2000 International Building Code (97 NDS)) Ver 6.00.8
By' Jim Mei Suntel Home Design on: 11 -04 -2005
Project: YAMHILL R Location: Beam Nr 4 at nook
Summary'
5 125 IN x 12.0 IN x 10 0 FT 24F -V4 Visually Graded Western Species Dry Use
Section Adequate By: 66.9% Controlling Factor: Area Depth Required 9.25 In
LOADING DIAGRAM
I
Reactions
Live Load Dead Load Total Load Uplift Load
A 4088 Lb 2622 Lb. 6710 Lb 0 Lb
B 4088 Lb 2622 Lb 6710 Lb 0 Lb
Span
Uniform Loading
Live Load Dead Load Self Weight Total Load
W 818 Plf 510 PIf 15 PIf 1342 PIf
B
Span 10 ft
Combination Roof and Floor Beamf 2000 International Building Code (97 NDS) j Ver 6. 00.8
a
By Jim Mel Suntel Home Design on: 11 -04 -2005 09:50 :45 AM
Project: YAMHILL p Location: HDR 0 GREAT RM
a Summary
5.125 IN x 9 0 IN x 8.5 FT 24F-V4 Visually Graded Western Species Dry Use
Section Adequate By 49.6% Controlling Factor Section Modulus Depth Required 7.5 In
Deflections:
Dead Load: DLD= 0 11
Live Load: LLD= 0 14
Total Load: TLD= 0.25
Reactions (Each End)
Live Load: LL -Rxn= 2794
Dead Load: DL -Rxn= 2202
Total Load: TL -Rxn= 4996
Bearing Length Required (Beam only support capacity not checked): BL= 1.50
Camber Regd. C= 0 16
Beam Data:
Span: L= 8.5
Maximum Unbraced Span: Lu= 2.0
Live Load Deflect. Criteria. L1 360
Total Load Deflect. Criteria: L/ 240
Camber Adjustment Factor CAF= 1 5
Roof Loading:
Roof Live Load -Side One: RLL1= 25.0
Roof Dead Load -Side One. RDL1= 17.0
Roof Tributary Width -Side One: RTW1= 12.0
Roof Live Load -Side Two RLL2= 25.0
Roof Dead Load -Side Two RDL2= 17 0
Roof Tributary Width -Side Two. RTW2= 1.5
Roof Duration Factor Cd -roof= 1 15
Floor Loading:
Floor Live Load -Side One: FLL1= 40.0
Floor Dead Load -Side One: FDL1= 15.0
Floor Tributary Width -Side One: F1W1= 8.0
Floor Live Load -Side Two: FLL2= 40 0
Floor Dead Load -Side Two: FDL2= 15 0
Floor Tributary Width -Side Two: FTW2= 0.0
Floor Duration Factor Cd -floor= 1 00
Wall Load: WALL= 100
Beam Loads:
Roof Uniform Live Load: wL -roof= 338
Roof Uniform Dead Load (Adjusted for roof pitch) wD- roof 287
Floor Uniform Live Load: wL -floor= 320
Floor Uniform Dead Load: wD -floor= 120
Beam Self Weight: BSW= 11
Combined Uniform Live Load: wL= 658
Combined Uniform Dead Load: wD= 518
Combined Uniform Total Load: wT= 1176
Controlling Total Design Load: wT -cont= 1 176
Properties For 24F V4- Visually Graded Western Species
Bending Stress: Fb= 2400 PS
Shear Stress. Fv= 190 PS
Modulus of Elasticity Ex= 1800000 PS
Ey= 1600000 PS
F perp= 650 PS
Fb cpr= 1200 PS
Pa:- 2754 PS
Fv'= 219 PS
Stress Perpendicular to Grain.
Bending Stress of Comp Face in Tension.
Adjusted Properties
Fb' (Tension)
Adjustment Factors. Cd =1 15 C1 =1 00
FY'
Adjustment Factors. Cd =1 15
Design Requirements:
Controlling Moment:
4.25 ft from left support
Critical moment created by combining all dead and live loads.
Controlling Shear
At a distance d from support.
Critical shear created by combining all dead and live loads.
Comparisons With Required Sections:
Section Modulus (Moment):
Area (Shear)
Moment of Inertia (Deflection)
V= 4197 LB
Sreq= 46.26
S= 69 19
Areq= 28.81
A= 46 13
1 req= 180 46
I= 311.34
IN
IN L1740
IN L1414
LB
LB
LB
IN
IN
FT
FT
X DLD
PSF
PSF
FT
PSF
PSF
FT
PSF
PSF
FT
PSF
PSF
FT
PLF
PLF
PLF
PLF
PLF
PLF
PLF
PLF
PLF
PLF
M= 1 0617 FT -LB
N3
N3
N2
N2
N4
N4
Combination Roof and Floor Beam[ 2000 International Building Code (97 NDS) j Ver 6.00.8
By Jim Mei Suntel Home Design on. 11 -04 -2005
Project: YAMHILL R Location: HDR GREAT RM
Summary
5 125 IN x 9 0 IN x 8.5 FT 24F V4 Visually Graded Western Species Dry Use
Section Adequate By: 49 6% Controlling Factor: Section Modulus Depth Required 7.5 In
LOADING DIAGRAM
Reactions
Live Load Dead Load Total Load Uplift Load
A 2794 Lb 2202 Lb 4996 Lb 0 Lb
B 2794 Lb 2202 Lb 4996 Lb 0 Lb
Span
Uniform Loading
Live Load Dead Load Self Weight Total Load
W 658 PIf 507 PIf 11 PIf 1176 PIf
Span 8.5 ft
Multi -Span Roof Beam[ 2000 International Building Code (97 NDS)1 Ver 6.00.8
By' Jim Mei Suntel Home Design on: 11-04- 2005 09:50:47 AM
Project: YAMHILL R Location: MDR Q bonus rm
Summary'
5.5 IN x 11.5 IN x 4.5 FT I #2 Douglas Fir -Larch Dry Use
Section Adequate By' 22.2% Controlling Factor Area I Depth Required
Center Span Deflections:
Dead Load:
Live Load:
Total Load:
Center Span Left End Reactions (Support A):
Live Load:
Dead Load:
Total Load:
Bearing Length Required (Beam only support capacity not checked):
Center Span Right End Reactions (Support B):
Live Load:
Dead Load:
Total Load:
Bearing Length Required (Beam only support capacity not checked):
Beam Data:
Center Span Length:
Center Span Unbraced Length -Top of Beam:
Center Span Unbraced Length Bottom of Beam:
Live Load Duration Factor
Pitch Of Roof:
Live Load Deflect. Criteria:
Total Load Deflect. Criteria:
Center Span Loading:
Uniform Load:
Roof Live Load:
Roof Dead Load:
Roof Tributary Width Side One:
Roof Tributary Width Side Two:
Beam Self Weight:
Wall Load:
Total Live Load:
Total Dead Load (Adjusted for Roof Pitch)
Total Load:
Point Load
Live Load:
Dead Load:
Location (From left end of span)'
Properties For #2 Douglas Fir -Larch
Bending Stress:
Shear Stress.
Modulus of Elasticity
Stress Perpendicular to Grain:
Adjusted Properties
Fb' (Tension)
Adjustment Factors. Cd =1 15 Cf=1 00
Fee
Adjustment Factors: Cd =1 15
Design Requirements:
Controlling Moment:
2.25 Ft from left support of span 2 (Center Span)
Critical moment created by combining all dead loads and live loads on span(s) 2
Controlling She Y {r'
At a distal 6 e d from left support of span 2 (Center Span)
Critical shear created by combining all dead loads and live loads on span(s) 2
Comparisons With Required Sections:
Section Modulus (Moment)
Area (Shear)
Moment of inertia (Deflection).
9.91 In
DLD- Center-
LLD- Center=
TLD- Center='
LL- Rxn -A=
DL- Rxn -A=
TL- Rxn -A•
BL -A=
LL- Rxn-B=
DL- Rxn -B=
TL- Rxn -B=
BL -B=
L2=
Lug Top=
Lu2- Bottom=
Cd=
RP=
L/
L/
RLL -2=
RDL -2=
Trib -1 -2=
Trib -2 -2=
BSW=
Wall -2=
wL -2=
wD -2=
wT -2=
PL -2=
PD -2=
X -2=
Fb=
Fv=
E=
Fc_perp=
Fb'=
Fv'=
V=
Sreq=
Areq=
A=
I req=
1=
0 01 IN
0.01 IN= L/4482
002 IN= L/2204
1706 LB
1 761 LB
3468 LB
1.01 IN
1706 LB
1761 LB
3468 LB
1.01 IN
4.5 FT
0.0 FT
4.5 FT
1 15
0 12
360
240
2.5 0 PSF
17.0 PSF
10 FT
1.0 FT
15 PLF
0 PLF
50 PLF
34 PLF
99 PLF
3188 LB
3300 LB
225 FT
875 PSI
85 PSI
1300000 PSI
625 PSI
1006 PSI
98 PSI
7551 FT -LB
3374 LB
9004
121.23
51 77
63.25
75.89
697.07
1N3
IN3
1N2
1N2
IN4
1N4
Multi -Span Roof Beam{ 2000 International Building Code (97 NDS) 7 Ver 6.00.8
By Jim Mei Suntel Home Design on: 11 -04 -2005
Project: YAMHILL R Location. HDR bonus rm
Summary
5.5 IN x 11.5 IN x 4.5 FT #2 Douglas Fir -Larch Dry Use
Section Adequate By 22.2% Controlling Factor: Area Depth Required 9.91 In
LOADING DIAGRAM
Reactions
Live Load Dead Load Total Load Uplift Load
A 1706 Lb 1761 Lb 3468 Lb 0 Lb
B 1706 Lb 1761 Lb 3468 Lb 0 Lb
Center Sean
Uniform Loading
Live Load Dead Load Self Weight Total Load
W 50 PIf 34 Plf 15 Pit 99 PIf
Point Loading
Live Load Dead Load Location
P1 3188 Lb 3300 Lb 2.2 Ft
P1
1
Center Span 4.5 ft