Operations Service Manual
FOODSERVICE EQUIPMENT
Model: FSH-2A-99
F113
Giles Enterprises. Inc.
An 1809001 Registered Company
2750 Gunter Park Drive West Montgomery AL 36109 USA
Fax. (334) 272-3561 Internet: www.gilesentoom
Service Hotline (Toll Free): 1-800-554-4537 (USA Canada Only)
Form No. 60200 (Release date. 07/98)(Revision Date: 01/28/09)(Rev
FSH-2,
FSH-2A-99,
FSH-2A-99W
11183
�!J
LIMITED WARRANTY
Subject to the terms and conditions of this Limited Warranty as herein stated, all Giles Enterprises
Inc Foodservice Equipment and parts purchased new from an authorized Giles Enterprises, Inc
representative are warranted as to defects in material or workmanship for a period of 12 months
from the date of installation, provided, however that with regard to labor costs in connection with
this warranty see below AU installations must be made by a qualified installing agency in accor-
dance with all applicable codes and/or regulations in the jurisdiction in which installed. Limited war
ranty coverage is extended to the original owner only and is void if the unit is resold
During the Limited Warranty period, Giles Enterprises, Inc will replace or recondition, at its factory
any part or parts of this unit which Giles Enterprises. Inc. inspectors judge defective, provided the
unit has been subjected to normal usage, properly installed, operated and serviced. This Limited
Warranty does not cover cosmetic damage, and damage due to acts of God, accident, misuse alter-
ation, negligence abuse of the Giles Foodservice Equipment or the use of unorthodox repair meth-
ods All parts replaced under this Limited Warranty carry only the unexpired term of this Limited
Warranty Limited Warranty service may be furnished only by an authorized Giles Enterprises, Inc
representative.
If Limited Warranty service is requested Giles Enterprises Inc. will send factory authorized serv-
ice representatives to repair recondition, replace or inspect units of its manufacture with such labor
being rendered without cost to owner for ninety (90) days from the date of installation. Otherwise
service, including labor and transportation charges or other expenses, in connection with the
removal or installation of any part or parts supplied under this Limited Warranty are specified on the
original sales contract between the purchaser and the authorized Giles Enterprises, Inc. represen-
tative
Giles Enterprises, Inc. reserves the right to change or improve its equipment and parts in any way
without obligation to alter such equipment or parts previously manufactured.
Giles Enterprises, Inc makes no further warranties, express or implied including implied warranties
of merchantability or fitness for a particular purpose, and has no other obligation or liability not
specifically stated herein
Repair or replacement as provided under this Limited Warranty is the exclusive remedy Giles
Enterprises, inc. shall not be liable for any incidental or consequential damages for breach of any
express or implied warranty on this product, except to the extent prohibited by applicable law Any
implied warranty of merchantability or fitness for a particular purpose on this product is limited in
duration to the duration of this Limited Warranty
Used Giles Enterprises Inc Foodservice Equipment or parts or Giles Enterprises, Inc. Foodservice
Equipment or parts not purchased from an authorized Giles Enterprises, Inc. representative, carry
no warranties, express or implied.
Table Of Contents
Safety
Safety Overview
Specific Safety Precautions
1
1 -01
1 -02.
1 -03
1 -03.
1 -03 01.
1 -03 02
1 -03 03
1 -03.04
1 -03 04
1 -03 06
Introduction
Construction
Standard Features
Optional Feature
Specifications
Overall Dimensions
Overall Dimensions
Overall Dimensions
Overall Dimensions
Regulatory Listings
Unit Weights
3 Overview
3 -01. Filter Area
3 -02 Control Panel
3 -03 Accessories (Included)
for FSH -2
for FSH-2A
for FSH -2A -99
for FSH- 2A -99W
2 Installation
2 -01. Location
2 -02 Unpacking
2 -03 Electrical Requirements
2 -03 01 Electrical Connections (Overview)
2 -03 02 Hood Power Connection
2 -03 03 Hood and Appliance interlock Connection
2 -03 04 Fire Alarm Connection
2 -04 Fryer and Oven Limitations and clearances
2 -04 01 Fryer Limitations under FSH -2, FSH -2A, FSH -2A -99
2 -04 02 Oven Limitations under FSH- 2A -99W
2 -04 03 Fryer Clearances for FSH -2
2 -04 04 Fryer Clearances for FSH -2A
2 -04 05 Fryer Clearances for FSH -2A -99
2 -04 06 Oven Clearances for FSH- 2A -99W
2 -05 Fire Suppression System
2- 05.01. Fusible Links and Gas Cartridge Location
2 -05 02 Fire Exinguishing Nozzles and Tank Location
2 -05 03 Manual Pull Diagram
2 -06 Restraining Device
Model: FSH -2, FSH- 2A -99,
FSH- 2A -99W
1
1
1
1
2
2
3
4
5
6
6
7
7
8
8
9
9
10
11
11
11
12
13
14
15
16
17
17
18
19
20
21
22
24
26
iii
Model: FSH-2, FSH- 2A -99, Table Of Contents
FSH- 2A -99W
4 Operation
4-01. Hood Operation
4 -02 Hood Filters and Filter Maintenance
4-02 01 Hood Filter Table
4-02 02 Baffle Filter Removal
4 -02 03 Baffle Filter Installation
4-02 04 Baffle Filter Missing
4-02 05 Baffle Filter Cleaning Procedure
4-02 06 EAC Filter Removal
4-02 07 EAC Filter Installation
4-02 08 EAC Filter Status.
4-02 09 EAC Fitler Cleaning
4-02 10 Charcoal Filter Removal
4-02 11. Charcoal Filter installation
4 -02 12 Charcoal Filter Missing
4-02 13 Charcoal Replacement Procedure
4-02 14 Ultra Violet Lamp Removal
4 -02 15. Ultra Violet Lamp Installation
4-02 16. Ultra Violet Lamp Cleaning
4-03 Maintenance
4 -03 01 Monthly Interlock Check
4-03 02 Quarterly Hood Cleaning
4-03 03 Semi Annual Fire Suppression System Servicing.
4-03 04 Annual Fire Suppression System Servicing
4-03 05 Twelve Year Suppression System Servicing
4-03 06 Maintenance and Service Log
5 Hood Cleaning 43
5 -01. Cleaning 43
6. Troubleshooting 45
6-01. Troubleshooting Procedures 45
7 Parts List 47
7 -01. Parts Ordering and Service Information 47
7 -02 Ventless Hood -Front 48
7 -03 Ventless Hood -Rear 50
8. Wiring Diagrams 53
8 -01. Wiring Diagram FSH -2, FSH -2A, FSH- 2A -99W 208 240/60/1 54
8-02 Wiring Diagram FSH -2, FSH -2A, FSH -2A 99W 208 240/60/1 w /lLS 56
8 -03 Wiring Diagram FSH -2 FSH -2A, FSH -2A -99W 208 240/60/1 wJUV 58
8-04 Wiring Diagram FSH -2, FSH -2A, FSH -2A -99W 208 240/60/1 w/lLS UV 60
8 -05 Wiring Diagram FSH -2A -99 ONLY 208 240/60/1 62
8-06 Wiring Diagram FSH -2A -99 ONLY 208 240/60/1 w /ILS 64
iv
29
29
29
29
30
31
32
32
32
33
33
34
35
35
36
36
37
37
38
39
40
40
41
41
41
42
s. Table Of Contents
Wiring Diagrams Continued
8 -07 Wiring Diagram FSH -2A -99 ONLY 208 240160/1 w /UV
8-08 Wiring Diagram FSH -2A -99 ONLY 208 240/60/1 w /iLS UV
8 -09 Wiring Diagram FSH -2 FSH -2A, FSH -2A 99, FSH- 2A -99W 208 240/60/1
Model: FSH -2, FSH- 2A -99,
FSH- 2A -99W
66
68
70
v
Safety
Safety Overview
The instructions contained in this manual have been prepared to aid you in learning the proper procedures
for installing and servicing your new unit.
Throughout this manual, safety precautions are identified through the use of the safety alert symbol and
three signal words DANGER,WARNING, and CAUTION All safety alert information precedes the
step(s) to which they apply. Suggested, recommended, or other noteworthy information is identified
through the use of NOTES. Additionally certain words are used to indicate a specific meaning or to add
emphasis
The following words are used as indicated throughout the manual.
Shall: understood to be mandatory
Should: understood to be advisory
May understood to be permissive
W ill: indicates a future event/condition to occur
A or
Used in conjunction with signal words (DANGER,WARNING, or CAUTION) to alert you of potential per
sonal injury hazards, immediately preceding precautionary measures that pertain to subsequent steps)
Obey all safety messages that follow this symbol to avoid possible injury or death. Failure to adhere to
safety precautions identified by the safety alert symbol may also void the warranty.
Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.
Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury
Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury
Also used to alert against unsafe practices
Model: FSH -2, FSH- 2A -99,
FSH- 2A -99W
•When used without the safety alert symbol, CAUTION indicates a potentially hazardous situation which,
if not avoided, may result in equipment/property damage, and void the warranty
NOTE:
Identifies suggested, recommended, or other noteworthy information.
VII
Model: FSH -2, FSH- 2A -99,
Safety
Specific Safety Precautions
For your safety please observe the following precautions when operating or servicing your Giles equip-
ment. Read the following important safety information to avoid personal injury and /or damage to the
equipment.
Turn off the unit and unplug the power cord before cleaning or performing maintenance
DO NOT hose down the unit interior or exterior with water
Failure to comply with these DANGER notices will result in death or serious injury, equipment/property damage,
and void the warranty
viii
Consult a qualified electrician to ensure that:
all electncal specifications and codes are met.
circuit breakers and wiring are of sufficient rating and gauge
FSH- 2A -99W
The unit must be properly grounded and all electrical specifications must be met during installation.
Improper installation, adjustment, alteration, service or maintenance could result in death or serious injury, equip
ment/property damage, and void the warranty
DO NOT use or store gasoline or other flammable liquids or vapors in the vicinity of this or any other appliance!
Failure to comply with WARNING notices could result death or serious injury and equipment/property damage
and void the warranty
Internal ultraviolet radiation source
Keep protective bamer in place
Replace all removable parts after servicing.
An interlock is provided to reduce exposer to excessive ultraviolet radiation. DO NOT defeat the purpose of the
interlock.
x
Model: FSH -2, FSH- 2A -99,
Safety
FSH- 2A -99W
NOTE.
An HVAC specialist may be required for installations to confirm proper air
exchange and the heat load capabilities of the on site AC system
Exhaust ventilation is recommended for areas in which recirculating hoods are used We recommend
50 CFM per lineal ft. of hood.
•This amount could vary based on local codes and the site specific installation requirements
Notes:
Safety
The unit must be adequately and properly grounded. Improper grounding may result in electrical shock.
Always refer to your local electrical code to ensure proper grounding of this or any other electrical equip-
ment. Always consult with an electrician or other qualified service person to ensure breakers and wiring are
of sufficient rating and gauge for the equipment being operated.
Ensure the unit is positioned in a secure, safe location.
Consult an electrician to ensure all electrical specifications have been met and the unit rs properly grounded. The
wiring diagrams contained in this manual should aid your electncian in the installation of your unit.
The electronic components of the Control Panel are impact sensitive Exercise care around the Control Panel to
maintain proper operation.
During cleaning of the unit
DO NOT steam clean.
DO NOT use products containing chlorine
DO NOT use abrasive products, steel wool or scouring pads
DO NOT modify, alter or add attachments to this equipment)
Failure to comply with these CAUTION notices may result in equipment/property damage and void the warranty
The unit must remain in the upright (vertical) position.
Exercise care when removing the wooden crate from around the unit.
DO NOT operate the unit unless you fully understand the components and their intended function (see Section
3)
Model: FSH -2, FSH- 2A -99,
FSH- 2A -99W
NOTE.
If the crate is damaged upon receipt, immediately inspect the unit and notify the camer of any damage to the
unit.
To aid the electrician, an electncal winng diagram is contained in this manual. Refer to the wiring diagram during
installation or servicing
Comply with all appropriate state and/or local heath regulations regarding the cleaning and sanitation of equip-
ment.
ix
Introduction
Congratulations on the purchase of your new Giles Free Standing Ventless Hood, Model FSH -2 FSH -2A,
FSH -2A -99 or FSH -2A -99W manufactured by Giles Enterprises, 'Inc. Montgomery Alabama (USA) here-
after referred to as 'Giles' The Free Standing Ventless Hood is a product of extensive research and test-
ing. Every unit is thoroughly inspected and tested prior to shipment. Proper care and maintenance will
ensure years of trouble -free service
The Giles Ventless Hood System is used in conjunction with various listed cooking appliances to accom-
plish removal of grease vapors and objectionable odors which may be generated during cooking The hood
system performs this function through the use of what is commonly referred to as an electronic air clean-
er (EAC) Electronic air cleaners use an electrical charge to remove contaminants from the air as they pass
through the EAC.
To help protect your investment in this equipment, we recommend taking a few moments to familiarize
yourself with the installation, cleaning and maintenance procedures contained in this manual Read these
instructions before installation and use Adherence to these recommended procedures minimizes the
potential for costly down-time' and equipment repairs. Please retain this manual for future reference
All of the unit's exterior parts are constructed of stainless steel
Three Staae Filtration -uses three different filters to remove particulate matter from the air
Ultimate Ventless:
Model: FSH -2, FSH- 2A -99,
FSH- 2A -99W
Extinauishinc_System -built into the hood to extinguish an accidental fire from the Fryer installed
underneath the hood
Ultra Violet light in conjunction with Giles patented air filtration system
improves emission cleaning and odor control as well as keeping the unit
free from grease build up
Interlockina Start System (ILS) Interlocking Start System (ILS) -This system will cause the Hood and
the Appliance below the Hood to shut down when the hood filters need
to be cleaned or are not properly installed. ILS is required by some
cities and /or states Please check with your local code officials to see if
this system is required.
1
Model: FSH -2, FSH-2A-99,
FSH- 2A -99W
2
Fire
Detection
Bracket
fire Norm
Junction 0001
U
FRONT
INCHES [MILLIMETERS]
a 24 3/16 [613.92].
L+-+1 o
m
A
31 1/2 [800.44]-...
30 1/4 [767.66]
FSH -2 (A)
FSH -2 (B)
FSH -2 (C)
FSH-2 (D)
FSH -2 (E)
FSH -2 (F)
FSH-2 (G)
FSH-2 (H)
RIGHT SIDE
1 20-1 /8 I
18-5/8 I
I 16-1/8 1
15-5/8
I 15-1/8 I
I 14-1/8 I
I 10-1/8 I
0
N
N
a
m
609 6
511.2
473.1
409 6
396 9
384 2
358.8
2572
Air Outlet
Fire Domper)1
I
-29 11/16 [75352]
BACK
Introduction
o�
"Coclxe' Sight
Hole
Remote Fire
U Pull Connection
Introduction
Fire TialaQD'QT
Detection
Bracket
a i.
0
n
n 15 1/4 [387.84]
m
a
Fire Alarm
.rancho Box 7
X —I
FRONT
INCHES [MILLIMETERS]
a
RECOMMENDED TO MONS
lIut TO MUM
m
24 3/16 [613.92]
Air Outlet
40 1/16 [1016.88] m Fre Dumper) 1
li r ha 1 0 i�
1 or 0
Fire Suppremion
Q" Note
0
37 5/8 [954.98]
38 3/4 [983.56]
RIGHT SIDE
Interlock
De —en tootle
Service
arenas=
DOCKING ,OPENING WIDTH
MODEL (LETTER DESIGNATION INCHES M
FOR OPENING)
FSH -2A (A) 24 609 6
FSH -2A (B) 20-1/8 511.2
FSH -2A (C) 18-5/8 1 473 1
FSH -2A (D) 16-1/8 409 6
FSH -2A (E) 15-5/8 396.9
FSH -2A (F) 15-1/8 384.2
FSH -2A (G) 14-1/8 1 358.8
FSH -2A (H) 1 10-1/8 1 257.2
Model: FSH -2, FSH- 2A -99,
FSH- 2A -99W
U
29 11/16 [753.52]
BACK
Remote Fire
3
Model: FSH -2, FSH- 2A -99,
FSH- 2A -99W
4
Fire
Detection
Bracket
Pk Flow
x
_1 I
FRONT
INCHES [MILLIMETERS]
Air discharges to the Left and Right
Fee Alarm
Junction Ben
40 1/16 [1016.88] 1 1401. 10 CEILING
7 13/16 [198.00]
15 1/4 [387.84] A
37 5/8 [9541
38 3/4 [983.56]
man SInF
6ntertada
Tie-In Leads
Service
Entrance
DO CKING OPENING WIDTH r
MODEL (LETTER'DESIGNATION
F OR OPENING) INCHES MILLIMETERS
FSH-2 (A) 24 609 6
FSH -2 (B) 20-1/8 5112
FSH -2 (C) j 18-5/8 473 1
FSH-2 (D) 16-1/8 409 6
FSH -2 (E) J 15-5/8 396.9
FSH -2 (F) 15-1/8 J 384.2
FSH-2 (G) 14118 358.8
FSH -2 (H) f 10-1/8 I 2572
Introduction
24 3/16 [613.92]
4
0 0
sght
Cr. Hole
29 11/16 [753.52]
HACK
Remote Fire
been
Introduction
Fire
Detection
Bracket
Air discharges to the Lett and Right
Fre Alarm
Junction Box
r 40 1/16 [1016.88] 1
FRONT
INCHES [MILLIMETERS]
AAN. TO CERJNG
15 1 '4 [387.84]
35 1/16 [890.30]
36 3/16 [918.87] 1---
24 3/16 [613.92]
N
m
Model: FSH -2, FSH- 2A -99,
FSH- 2A -99W
Fre Suppression
"Cocked" Sight
co Interlock O Hole
Tie —In Leads
Service Remote Fre
Entrance Suppression
-c Pull Connection
v
RIGHT SIDE BACK
5
Model: FSH -2, FSH- 2A -99,
FSH- 2A -99W
UL (US and Canada)
NSF
CE
6
FSH -2
FSH-2A
FSH -2A -99
FSH -2A -99W
Introduction
462 146 327 148
609 277 454 206
535 243 380 173
635 289 480 218
J
Installation
This section provides a summary of the procedures necessary for proper installation of your unit. To help pre-
vent personal injury or equipment damage, please ensure the following steps are taken.
NOTE.
*The decibel level of the hood when operating is approximately 65 dB's
DO NOT MODIFY, ALTER OR ADD ATTACHMENTS TO THIS EQUIPMENT
Model: FSH -2, FSH- 2A -99,
FSH- 2A -99W
1. Before unpacking the unit and assembling the unit, using the dimensions and clearances shown in
Section 2 -04 03. and 2-04 06 determine the location of the unit.
2 Keep the unit and the surrounding area free and clear from combustible materials
3 Please provide adequate room for servicing and proper operation of the unit. Also provide
adequate ventilation in the operating area where necessary
4 Before operating, make sure the unit is in a secure position and will not move
NOTE:
An HVAC specialist may be required for installations to confirm proper air
exchange and the heat load capabilities of the on site AC system
Exhaust ventilation is recommended for areas in which recirculating hoods are used We recommend
50 CFM per lineal ft. of hood
'This amount could vary based on focal codes and the site specific installation requirements
7
Model: FSH -2, FSH- 2A -99,
FSH- 2A -99W
CC.
Installation
Your unit may arrive enclosed by a wooden crate The Hood is secured to a wooden platform by means of
high- tensile strength strapping
NOTE.
If the crate is damaged, immediately inspect the unit and notify the carrier of any damage to the
unit.
Exercise care when lifting or moving the unit.
Exercise care when removing the wooden crate from around the unit.
Failure to comply with these CAUTION notices may result in minor or moderate injury, equip
ment/property damage, and void the warranty.
1. Carefully cut and remove the plastic shipping wrap and the strapping mentioned above
2 Use pliers to loosen wire hooks which secure the wooden crate around the unit. Remove the
wooden crate
3 Carefully remove the unit from the shipping platform Your new FSH -2, FSH -2A, FSH -2A -99 or FSH
2A-99W is extremely heavy see Section 1 -03.04 for unit weights. Great care should be taken in lift-
ing or moving the unit to prevent personal injury or equipment damage
Consult a qualified electrician to ensure all electrical specifications have been met and that the unit is properly
grounded
The unit must be adequately and properly grounded. Improper grounding may result in electrical
shock. Always refer to your local electrical code to ensure proper grounding of this or any other
electrical equipment. Always consult with an electrician or other qualified service person to
ensure breakers and wiring are of sufficient rating and gauge for the equipment being operated.
Improper installation, adjustment, alteration, service or maintenance could result in death or serious injury equip
ment/property damage, and void the warranty
ood Electrical Requirements
nit Voltage r Hz Phase
8
FSH -2
FSH -2A
FSH -2A -99
FSH -2A -99W f
208 -240
208 -240
208 -240
208 -240
60
60
60
60
1
1
1
1
3
3
3
3
10
10
1 0
10
Installation
Connect Hood Power
3 Make all appropiate connections.
4 Reinstall Service Entrance Box Cover
Fire Alarm Tie-In Box
Interlock Tie-In Box
Service Entrance
Box
Connection to
Appliance
s uPPLy
P owER 140 400
Ec 10a
Model: FSH -2, FSH- 2A -99,
FSH- 2A -99W
1 Install appropriate Circuit Breakers in Hood Supply Power Box (Main Breaker Box) See Section 2 -03
for required Circuit Breakers
2 Remove Cover on Service Entrance Box and run appropriate size conduit and wire from the Service
Entrance Box to the Hood Supply Power box (Main Breaker Box) Allow enough conduit and wire so
the unit can be accessed for cleaning and servicing
9
Model: FSH -2, FSH- 2A -99,
FSH- 2A -99W
This connection will cause the Appliance installed below the Hood to shut down if any of the following
occurs
Any Filter becomes excessively dirty not allowing proper air flow through the Hood.
Any Filter is missing or not installed correctly
The Fire Extinguisher System is activated.
Interlock Hood to Appliance:
1 Remove Cover on Interlock Tie-In Box and run appropriate size conduit and wire from the Interlock
Tie-In Box to a Hood and Appliance Connection Box (Supplied by Customer) Allow enough conduit
and wire so the Hood can be accessed for cleaning and servicing
2 Make appropiate connections See Diagram below
3 Reinstall Interlock Tie-In Box Cover
10
/PRANCE
(SUPPLIED BY cuSTOMER)
BTEBLOOC RELAY IN HOOD
comm. POYIFR
r CONTROL POER
—HOOD SUPPLY POWER
(SUPPUED BY CUSTOMER)
I
L___1 1
I I I I
ill- -r r
"-1L
'+—iii- --F -----I---i---
-1 —4--e --4u
L —J L
CONTACTOR LOAD CENTER ammo BREAKER
(SUPPLIED BY CUSTOMER) (S PLIED BY OSIOMER)
-HOOD MID APPLIANCE
cEDYP ED BY CUSTOMER)
MPLYMCE SUPPLY POER—
(SPPiBD BY
Installation
NOTE:
If not using the ILS option, the Hood will continue to run and the Appliance will turn off when:
Any Filter becomes excessively dirty, not allowing proper air flow through the Hood.
Any Filter is missing or not installed correctly.
The Fire Extinguisher System is activated.
If using the 1LS option, the Hood and Appliance will turn off when:
Any Filter becomes excessively dirty, not allowing proper air flow through the Hood.
Any Fitter is missing or not installed correctly.
The Fire Extinguisher System is activated.
Installation
This connection will send a signal the Facility Fire Alarm System that the Hood Fire Extinguisher System
has been activated.
Fire Alarm Connection:
1 Remove Cover on Fire Alarm Tie-In Box and run appropriate size conduit and wire from the Box to
the Facility Fire Alarm System Allow enough conduit and wire so the Hood can be accessed for
cleaning and servicing
2 Make appropiate connections
3 Reinstall Fire Alarm Tie-In Box Cover
This section describes various limitations to the fryers and the oven that can be placed underneath the
hoods. Please note only Electric Fryers and Ovens that do not exceed the following limitations and follow-
ing clearances are approved to be placed under these hoods. Gas Fryers, Gas Ovens, or any other type of
appliances are not approved.
These Hoods are design for Electric Fryers Only!!! DO NOT USE ANY GAS APPLIANCES UNDER THE FSH
2, FSH -2A, FSH- 2A -99!!!
FSH -2
FSH -2A
FSH -2A -99
20 (Fryers only)
20 (Fryers only)
20 (Fryers only)
Model: FSH -2, FSH- 2A -99,
FSH- 2A -99W
110 380 Sq. In.
110 380 Sq In.
110 380 Sq In
11
Model: FSH -2. FSH-2A-99,
FSH- 2A -99W
12
This Hood is design for Electric Ovens Only!!! DO NOT USE ANY GAS APPUANCES UNDER THE
FSH- 2A- 99W!!!
FSH- 2A -99W
8 (Ovens only) 450F
Installation
ax kW Input Maio Oven Temperature
Installation
x
Ith
—29 11/16 [753.521
FRONT
INCHES [MILLIMETERS]
FSH -2 (A)
FSH -2 (B)
FSH -2 (C)
FSH-2 (D)
FSH -2 (E)
FSH -2 (F)
FSH -2 (G)
FSH -2 (H)
Fusible Link
7 11/16 [195.72]
3 MIN. [76.20]
L
'RECOMMENDED TO CEILING
MIN. TO CEILING
24
20-1/8
I 18-5/8
I 16-1/8
I 15-5/8
I 15-1/8
14-1 /8
10-1/8
1 i. -6 3/4 [171.62]
Fry Vat
RIGHT SIGH
DO CKING OPENING WIDTH
MODEL (LETTER DESIGNATIO
FOR OPENING) INCHE
Model: FSH -2, FSH- 2A -99,
FSH- 2A -99W
609 6
511 2
473.1
409 6
396.9
384 2
358.8
257.2
Fryer Only
O
co
0 O
N
m
13
Model: FSH -2, FSH- 2A -99,
FSH- 2A -99W
er Clearances for FSH-2A
14
Tluzia
q
FRONT
INCHES [MILLIMETERS]
0
tJ
RECOMMENDED TO CEILING
MN. TO CEILING
40 1/16 [1016.88]
Fusible Link
2 1/2 [63.50]
ai 7 11/16 [195.84]
m
N
3 NW. [76.20]
RIGHT SIDE
FSH -2A (A) 24 609 6
FSH -2A (B) 20-1/8 511 2
FSH -2A (C) 18-5/8 I 473.1
FSH -2A (D) 16-1/8 i 409 6
FSH -2A (E) 15-5/8 1 396 9
FSH -2A (F) 15-1/8 I 384 2
FSH -2A (G) 14-1/8 358.8
FSH -2A (H) I 10-1/8 2572
0
co
0 0
N
7 3/4 [197.60]
15 1/4 [387.84]
Fryer Only
DOCKING OPENING WIDTH X"
MODEL'(LETTER'DESIGNATION INCHES MILLIMETERS
FOR OPENING)
Installation
Installation
Fire
Detection
Bracket
2 1/2 [63.50]
Air Flow
SElit
FRONT
INCHES (MILLIMETERS)
Air discharges to the Left and Right
x
ir
Fire Alarm
Junction Box
Fusible Link
7 13/16 [198.00]
7 11/16 [195.84]
3 [76.20]
40 1/16 [1016.88]
__MIN. TO CEILING
FSH -2A -99 (A) 24 609 6
FSH-2A-99 (B) 20-1/8 511.2
FSH -2A -99 (C) 18-5/8 1 473 1
FSH -2A -99 (D) 16-1/8 409.6
FSH -2A -99 (E) 15-5/8 E 396.9
FSH-2A-99 (F) 15-1/8 384.2
FSH -2A -99 (G) 14-1/8 358.8
FSH -2A -99 (H) I 10-1/8 2572
Model: FSH -2, FSH-2A-99,
FSH- 2A -99W
Fry Vat
38 3/4 [983.56]
RIGHT SIDE
DOCKING OPENING WIDTH
MODEL (LETTER-DESIGNATION
I
�s FOR OPENING)....
NCHES MI
Fryer Only
15
Model. FSH -2, FSH- 2A -99,
FSH- 2A -99W
2 1/2 [63.50]
16
Fire
Detection
Bracket
Air discharges to the Left and Right
Air Flow
30 [762.00]
MAX.
32 [812.80]
37 3/16 [944.98]
FRONT
INCHES [MILLIMETERS]
Fusible Link
N
0)
d'
N
N
0)
40 1/16 [1016.88]
YIN. TO CELIAC
10 [253.72]
MIN.
1 23 [583.68
35 1/16 [890.30]
36 3/16 [918.87]
RIGHT SIDE
L.:
Installation
to
N
n
OVEN ONLY
0
In
N
0)
0)
Installation
The fire suppression system used in your Giles Ventless Hood is an Ansul R -102 Restaurant Fire
Suppression System (Standard UL 710B Listed) Final installation, charging and testing of the system
must be performed by an authorized Ansul distributor in accordance with the system's listing.
The fire suppression system is designed and UL-listed to provide fire protection for cooking appliances
such as fryers It protects your units, automatically, 24 hours per day The system contains piping, nozzles
(both appliance and plenum) and conduit for routing the fusible link cable through the hood.
Fusible Link 285 Degree F
Installed at Factory
Fusible Link 165 Degree F
Supplied Installed by
Ansul
See Appliance Fusible Link below
Appliance Fusible Link:
If less than 3 176 2] to cooking surface use
Fusible Link 165 Degree F
Supplied Installed by Ansul
If more than or equal to 3 [76.2] to cooking
surface use Fusible Link 135 Degree F
Supplied Installed by Ansul
INCHES [MILLIMETERS]
Appliance Cooking Surface
LT-20 R Cartridge
Supplied Installed by
Ansul
Model: FSH -2, FSH- 2A -99,
FSH- 2A -99W
17
Model FSH -2, FSH- 2A -99,
FSH- 2A -99W
ire.Exinguishing• Nozzles and Tank Location
All nozzles have been factory installed in the proper operating position. DO NOT MOVE OR ADJUST
18
Plenum Nozzle
Giles P/N 46426
Plenum Nozzle
Giles P/N 46426
FSH -2 Appliance Nozzle
Giles P/N 46426
FSH -2A Appliance Nozzle
Giles P/N 40131
FSH -2 Appliance Nozzle
Giles P/N 46426
FSH -2A Appliance Nozzle
Giles P/N 40131
Tank, 1 -1/2 Gallon
Giles P/N 39272
Installation
Installation
This Hood requires use of the Ansul R -102 Standard for a Manual Pull System The Manual Pull System
must be mounted on a near -by wall and connected to the Hood. This Manual Pull System is used to
activate the Fire Extinguisher System from a remote location. The Manual Pull System is supplied and
installed by Ansul
The following illustration is a typical Manual Pull installation Using this basic configuration the Hood may
be moved from the wall for Cleaning and Servicing without removing the Manual Pull from the wall.
0
Model: FSH -2, FSH- 2A -99,
FSH- 2A -99W
1/2 Conduit from Hood
90 Degree Pulley
90 Degree Pulley
Ansul Manual Pull
Assembly mounted
on the wall
19
Model FSH -2, FSH- 2A -99,
FSH- 2A -99W
Any Fryer placed under this Hood must be secured so that the Fryer can not move from below the Hood.
The following is an example of a restraining device that may be used. The appropiate restraining device
will vary depending on the Fryer the restraining device is not supplied with the hood.
20
Syfrq }fgch..Al:uCtaYtsmtT
Note: Be sure to maintain minumum and maxi-
mum clearances (see Section 2 -04 02 or 2 -04 03
after the Restraining Device is installed.
Installation
Overview
The following section provides a brief overview of the components, functions, and accessories of the Free.
Standing Hood, Model FSH -2 FSH -2A, FSH -2A -99 and FSH -2A -99W. Please review this section carefully
before proceeding any further
UV Sight Window
(optional)
Appliance Centering Bracket
Model: FSH -2, FSH- 2A -99,
FSH- 2A -99W
Filter Area
Figure 3 -01
Control Panel
Figure 3 -02
Fryer or Oven Area (Fryer or
Oven not shown)
21
N
N
Overview
*1
2
Hood Filter Cover
Ultra Violet Lamp
(optional)
3 Charcoal Fitter
4 EAC Filter
6 Grease Drip Cup
7 Grease Dnp Cup Safety Pin
8 Exhaust Stack
9 Appliance Fusible Link
-Not Shown
Model: FSH -2, FSH- 2A -99,
FSH- 2A -99W
Used to access the Electronic Air Cleaner (EAC) and Charcoal
Filters This cover must be in place and latched for the unit to oper-
ate. Ultra Violet Panel has sight windows.
Improves emission cleaning and odor control as well as keeping
the unit free from grease build -up, improving fire safety and lead-
ing to less maintenance. This lamp should be cleaned monthly and
replaced annually. DO NOT touch Lamp with bare hands
This Filter helps to remove odors generated during cooking. This
Filter should be replaced monthly NEVER attempt to clean a
Charcoal Filter. Keep a spare filter on hand (Giles 30248) for quick
change -out when needed! DO NOT remove the Charcoal Filter
while the Hood or the Fryer is operating to prevent contact with
electrical parts and avoid electrical shock.
The EAC Filter is an electrical device which removes grease vapor
and smoke generated by the fryer during cooking Power must be
turned OFF to the Hood and Fryer before removing the EAC for
cleaning. The EAC should be cleaned daily. DO NOT remove the
EAC Fitter while the Hood or the Fryer is operating to prevent
contact with electrical parts and avoid electrical shock.
The Baffle Filter is the first stage of the grease extraction and air
cleaning system found on these units. It is easily removed for daily
5 Baffle Filter cleaning. DO NOT remove the Baffle Fitter while the Hood or the
Fryer is operating to prevent contact with electrical parts and
avoid electrical shock.
Used to hold excess grease from the hood. This cup should be
cleaned daily or as needed.
Used to hold the Grease Drip Cup in place and to prevent the cup
from accidentally dropping
Located on top of the unit. Allow the recommended clearance
of 18" or a minimum clearance of 12° between the top of the
Exhaust Stack and the ceiling.
Used to detect a fire in the Fryer Vat. Be careful not to hit or
bump this link. Doing so may inadvertently cause the Fire
Extinguisher System to activate
23
a)
s
E
a)
0
Overview
1
2
3
4
5
6
7
*8
Not Shown
ON Indicator Light
(EAC Status)
WASH Indicator Light
(EAC Status)
CHECK Indicator Light
(EAC Status)
Hood Powered
Indicator Light
Fryer Powered
Indicator Light
Filter Missing
Indicator Light
Power Switch
Push and Hold to Start
Button
Model: FSH -2, FSH- 2A -99,
FSH- 2A -99W
Used to indicate the Electronic Air Cleaner (EAC) Filter is on or
powered
Used to indicate the EAC has become excessively dirty Do
not rely upon this light as a signal for routine cleaning of the
EAC Failure to clean the EAC daily will significantly decrease
the life of the charcoal filter Clean the EAC daily for best per
formance
Used to indcate the EAC Filter is no longer cleaning the air
The EAC Filter must be cleaned or repaired.
Used to indicate the Hood is powered and running.
Used to indicate power is available to the Fryer under the
hood.
Used to indicate the Baffle Filter or Charcoal Filter is missing
or not correctly in place
Used to turn power on to the Hood and will allow the Fryer
under the Hood to be turned on.
(Used with ILS (Interlocking Start) units only) Used after the
Power Switch is in the 'ON position, push and hold down
PUSH AND HOLD TO START' Button for 5 seconds allow-
ing the unit to start. This allows the Hood and the Fryer
underneath to both shut down if the Hood Filters become
excessively dirty
This option is required by some cities. Please contact your
local code officials to see if this is required in your city
25
Model: FSH -2, FSH- 2A -99,
FSH- 2A -99W
26
Baffle Filter
P/N 42300
EAC Filter
P/N 20520
Charcoal Filter
P/N 30248
Overview
Used for removing smoke and
contaminants from the air
Used for removing smoke and
contaminants from the air
Used for removing odors from
the arr
Overview
EAC Soak Tank
P/N 39327
UV Lamp
P/N 90226
Model: FSH -2, FSH- 2A -99,
FSH- 2A -99W
Used for cleaning EAC filter
Used for emission control
27
Model FSH -2, FSH- 2A -99,
FSH- 2A -99W
Notes:
28
l
Overview
Operation
This section describes the operation of and the filter maintenance for the Hood.
This section describes how to start the Ventless Hood Make sure all the Filters and UV Light are in place
and correctly installed before operating the unit.
1 Press the Power Switch to the ON A position, (if 1LS, then press and
hold the Push and Hold to Start switch, for 5 seconds) the foil
ing will occur
illuminates indicating the EAC filter is cleaning the air.
illuminates indicating the Hood is on and powered.
illuminates indicating power is available to the Fryer underneath the
Hood.
sight window illuminates indicting UV is operating
2 The Fryer underneath the Hood may now be turned on and used.
This section describes each Filter and It's maintenance required.
Baffle Filter
EAC Filter
Charcoal Filter
Ultra Violet Light
Clean daily
Clean daily
Replace every 30
days,
P/N 30248
Clean every 30
days
Replace annually
Section 4-02 06
Section 4-02 08
Section 4-02 12
Section 402 14
lam
RI,. TT—.
O
ROSH TO
STMT
ON
aFF
-ILS only
Section 4-02.07
Section 4-02,11
Never clean, only
replace
Section 4-02 15
Section 4-02.16
Model: FSH -2, FSH- 2A -99,
FSH- 2A -99W
Section 4-02 08
Section 4-02 09
Section 402 13
Section 4-02 15
29
Model: FSH-2, FSH-2A-99,
FSH-2A-99W
30
Operation
Operation
affle Filter installation
Model: FSH -2, FSH- 2A -99,
FSH- 2A -99W
Switch arm
must be
actuated by
the Baffle
Filter as
shown
31
Model: FSH -2, FSH- 2A -99,
FSH- 2A -99W
If the Baffle Filter is missing or not in place correctly the Filter BEM
Missing Light A will come on. See Section 7 -02.03 Baffle Filter e s
Installation. e e
o
o e.7
0
The Baffle Filter should be cleaned daily Place the Baffle Filter in a sink and clean with a mild degreaser
Dry thoroughly then reinstall in the unit.
32
Hood Filter Cover
Operation
Operation
Hood Filter Cover
EAC Air Flow Arrow locatated
on the left or right of the EAC
Handle and must point up
The three indicator lights on the Control Panel display the status of the EAC Filter
ON The EAC Filter is in place and pow-
ered.
el WASH The EAC Filter is becoming excessive-
ly dirty and must be cleaned. If this
light is on for more then 2 minutes an
intermittent alarm will sound, and
power to the Fryer underneath the
Hood will be turned off.
CHECK The EAC Filter is not operating, either
the filter is not properly connected to
the power source or it is damaged. If
this light is on for more then 2 min-
utes an intermittent alarm will sound,
and power to the Fryer underneath
the Hood will be turned off
Filter must align
with this pin
Model: FSH -2, FSH- 2A -99,
FSH- 2A -99W
1 0 R
1
O Wsrp
STAN
STMT
ON
E
0
E
OFF
33
Model. FSH -2, FSH- 2A -99,
FSH- 2A -99W
Do not bend the fins or break the ionizer wires on the EAC as this will prevent the EAC from
working properly and potentially void the warranty.
1 Mix 1/2 Gallon of a mild non-caustic biodegradable degreaser such
as Simple Green or Clean Magic, with 6 5 gallons of water in the
included Soak Tank
NOTE.
The mixed solution in the Soak Tank should last up to 30 days
without being changed.
2 Holding the contact plate 12 on the EAC slowly lower the fil-
ter into the Soak Tank.
3 After allowing the EAC to soak for 20 to 30 minutes, using the con-
tact plate 13, lift the EAC up and down approximately 1 to 2 to
help remove the grease residue
4 Slowly remove the EAC from the tank and rinse clean in a sink
using hot water
5 Allow the EAC to air dry thoroughly
34
Fins
Ionizer Wires
(9) Required
Operation
N
Do not dry the EAC either by running the hood to air dry or by running the appliance to heat dry.
This could potentially damage the EAC causing improper operation and voiding the warranty.
Operation
Hood Filter Cover
Hood Filter Cover
Model: FSH -2, FSH- 2A -99,
FSH- 2A -99W
za`rcoal. Filter [nstallaton
Switch must be actuated
by the filter
35
Model FSH -2, FSH- 2A -99,
FSH- 2A -99W
If the Charcoal Filter is missing or not correctly in place the Filter
Missing Light si will come on. See Section 4-02 11 Charcoal Filter
Installation.
Never attempt to clean the Charcoal Filter. Replace the Alter. The reuse of a Charcoal Filter can
cause damage to the unit.
36
Replace the Charcoal Filter every 30 days Use Replacement Part No. 30248
00
o•g 0
e e
O x000
O
HO mins&
ART
ON
P
N
Off
Operation
Operation
1. Place hood power switch off
2 Remove filter access cover
3 Disconnect UV Lamp wiring
harness from power supply
wiring harness
4 Loosen and remove thumb
screws on each side of lamp
guard.
5 Remove Lamp from holding
brackets.
1. Install new UV Lamp in holding
brackets
2 install lamp guard and tighten
thumb screws.
3 Connect UV Lamp wiring harness
to power supply wiring harness
4 Install all filters and access cover
5 Place hood power switch on
Model: FSH -2, FSH- 2A -99,
FSH- 2A -99W
37
Model: FSH -2, FSH- 2A -99,
FSH- 2A -99W
Do Not touch or handle UV Lamp with bare hands. This will greatly reduce the life of bulb.
To be accomplished every 30 days
Operation
1 Place hood power switch off
2 Remove filter access cover
3 Loosen and remove thumb screws at top of lamp guard.
4 Lightly spray a mild non caustic biodegradable degreaser such as Simple Green, onto the UV Light
and wipe off residue with a dry lint free cloth
5. Re- install lamp guard.
38
Operation
Model: FSH -2, FSH- 2A -99,
FSH- 2A -99W
This Section describes periodic maintenance for the Ventless Hood System Performance of these proce-
dures will maintain the units efficiency over time.
A Maintenance and Service Log is provided in this manual, see Section 4-03 06.
Your Giles Ventless Hood System incorporates an Interlock System to ensure the unit is operated in a safe
and effective manner Testing of the Interlock System should be conducted MONTHLY in the following man-
ner Use the form located in Section 4-06.06 Maintenance and Service Log, place a check in the box that cor-
responds to the test being performed. If a problem is found, call your service representative.
Baffle Filter Check-With the Power Switch in the 'OFF position remove the grease baffle Place
the Power Switch in the 'ON position. Check appliance power underneath the Hood, the appliance
should not turn on. Turn the Power Switch to the 'OFF position and reinstall the grease baffle into
the hood.
2 EAC Filter Check-With the Power Switch in the 'OFF" position remove the EAC Place the Power
Switch in the 'ON position, wait two minutes Check appliance power underneath the Hood the
appliance should not turn on. Reinstall the EAC
3 Charcoal Filter Check-With the Power Switch in the OFF position remove the Charcoal Filter
Place the Power Switch in the ON position. Check appliance power underneath the Hood, the
appliance should not turn on. Return the Power Switch to the OFF position. Reinstall the charcoal
filter
4 Filter Clogged Check -Place the Power Switch in the 'ON position. Place a piece of cardboard
over half the Grease Baffle Filter Check appliance power underneath the Hood, the appliance
should not turn on. A steady tone buzzer will sound if the cardboard is not removed. Return Power
Switch to the "OFF" position. Remove the cardboard.
During cleaning of the unit
DO NOT steam clean.
DO NOT use products containing chlorine
DO NOT use abrasive products, steel wool or scounng pads
Remove power from the unit. Remove the Hood Filter Cover and all Filters from the hood. Using a mild
degreaser clean the entire Hood Plenum and Blower Sections The hood must be cleaned every 3
months
39
Model: FSH -2, FSH- 2A -99,
FSH- 2A -99W
Operation
Service of the Fire Suppression System is to be conducted by qualified fire equipment personnel As a minimum,
field inspection of the Fire Suppression System is to be accomplished semi annually by qualified fire equipment
service personnel. Such maintenance shall consist of the following (Consult the Giles Enterprises Design
Installation, Recharge and Maintenance Manual for complete servicing guidelines).
Place fire extinguishing system locking bar on fire system when servicing hood.
1. Remove charging cartridge, inspect gasket for cuts and elasticity coat gasket with extreme tempera-
ture grease and reinstall. See Section 2- 06.01. Fusible Link and Gas Cartridge Locations
2 Remove tank, verify chemical is at proper level clean and coat 0 -ring with extreme temperature
grease and reinstall See Section 2-06 02 Fire Extinguisher Nozzle and Tank Locations
3 Check all nozzles to insure they are free of cooking grease buildup.
4 Test the remote manual pull station for activation and wear
5. Install test link and cut to simulate automatic actuation
6 Clean and inspect fusible finks.See Section 2 -06 01 for Fusible Link and Gas Cartridge Locations
7 Inspect wire rope for wear at pulleys and detectors and replace if necessary
8 Record maintenance date and maintain in a permanent file
Same as Semi Annual but all fusible links must be replaced with new fusible links. See Section 2- 06.01.
Fusible Link and Gas Cartridge Locations.
Do Not touch or handle UV Lamp with bare hands. This will greatly reduce the life of bulb.
Replace Ultraviolet Lamp annually
Same as Annual except for the following.
1. Replace R -102 fire suppression chemical
2 Hydrostatically test the tank and cartridge
3 Flow test the regulator
40
Operation
NY NY \Y
11 2
1 1 2
112
314
31415
314
314
314 5
314
314
3 4 5
3 4
3 1 4
3 4 5
3
3 4
3 4 5
3 4
3 4
3 4 5
3 4
3 4
3 4 1 5
3 41
3 4
3 4 1 5
3 4
3 4
3 4 5
3 4
3 4
3 4 5
3 4
3 4 5
3 4 5
3 4 5
3 4 5
3 4 5
AB 1 403
1 'Baffle Filter Check 2 EAC Filter Check
4 Filter Clogged 5 Quarterly Cleaning
7 Fire Suppression System replace 'Fusible Links
Inspection performed by a qualified fire equipment company
3 4
3 1 4 1
3 4 I5
3 4 1
3 4
3 4 1 5
3 4
3 4
3 4'1 5
3 4 '1
3 4
3 4 f 5
3 41
3 4
3 4 5
3 4
3 4
3 4 5
3 4
3 4
3 4 5
3 4
3 4
314 5
3 1 4
3 4
314 5
314
314
3 4 5
3 4
314
3 4 5
3 1 4
314
3 1 4
Model: FSH -2, FSH- 2A -99,
FSH- 2A -99W
1 1
I I
6*
6*
6*
6*
7*
5 6* 17*
6 7
3 Charcoal Filter Check
6 Fire Suppression System
8 Replace UV Lamp
(UV option Only)
41
Model. FSH -2, FSH- 2A -99,
FSH- 2A -99W
Notes:
42
Operation
Hood Cleaning
This section describes the cleaning of the hood. The hood must be cleaned every 3 months
Interior Disconnect cower to the unit. Remove the Filter Cover and all Filters from the hood. Using a
soft cloth, sponge or towel and a mild non caustic biodegradable degreaser clean the entire Hood
Plenum area and Filter Channels
Exterior remove power from the unit. Using a stainless steel cleaner clean all external stainless steel
parts
Filters To clean and replace Filters, see Section 4 02 01 Hood Filter Table
UV Lamp To clean and replace UV Lamp, see Section 4 02 01 Hood Filter Table
Model: FSH -2, FSH- 2A -99,
FSH- 2A -99W
43
Model: FSH -2, FSH -2A,
FSH- 2A -99, FSH- 2A -99W
Notes:
44
Hood Cleaning
Troubleshooting
This section describes troubleshooting procedures for the FSH -2, FSH -2A, FSH- 2A -99, FSH- 2A -99W
Refer to the wiring diagrams in Section 8 for more detailed analysis.
Electrical troubleshooting procedures should be performed ONLY by qualified service personnel.
Death or serious injury will result from contact with energized electrical components
Failure to comply with these DANGER notices will result in death or serious injury equipment/property
damage, and void the warranty
Hood will not turn on
Filter Missing Light on
Check or Wash Light on
a. (ILS only) Push and Hold
button not held for 5 seconds
lb. Power switch bad
c. Improper supply voltage
d. Hood cover not closed
e. Not connected to power
source
f. Circuit breaker tripped
a. Baffle filter is not installed
a. EAC shorted
b. EAC dirty
c. High voltage power supply
faulty.
d. High voltage wires shorted.
e. Bad contact plate
Model: FSH -2, FSH- 2A -99,
FSH- 2A -99W
Hold down Push and Hold
button until unit remains
running
b. Replace power switch
c. Connect to proper voltage
source
a.
d. Close hood cover
e Connect to proper power
source
ff
Reset Circuit breaker
a. Install Baffle filter
b. Charcoal filter is not installed b. Install charcoal filter
a. Replace or repair EAC
c.
d.
e.
Clean EAC.
Replace high voltage power
supply
Correct shorted condition.
Replace contact plate
45
Model. FSH -2, FSH- 2A -99,
FSH- 2A -99W
Fryer or Oven will not turn on
Hood Power Light on
Filter Missing Light on
Fryer or Oven will not turn on
Hood Power Light on
Buzzer emitting a continuous
tone
Fryer Powered light off
Fryer or Oven will not turn on
Hood Power Light on
Buzzer emitting a pulsating tone
Fryer Powered Light off
la.
b
lc.
a.
l b.
c.
e.
a
b.
c.
,d.
e
f
9.
UV Lamp not illuminated a.
b
c.
46
d.
Baffle Filter missing
Baffle Filter not installed
properly
Charcoal Filter missing
Charcoal Filter clogged
Baffle Filter clogged
Vacuum switch out of
adjustment
Kinked vacuum line
Fan running slow
EAC shorted
EAC dirty
EAC power supply faulty
EAC wires shorted
Bad contact plate
EAC module faulty
EAC ionizer wire broken or
missing
Bad Connection
Lamp Blown
Filters not installed correctly
Access Pannel not installed
e. Bad Ballast
a.
b
1c*
a.
lb
c.
Id.
e.
a
b.
c.
d.
e.
f.
9
a. Reconnect
b Replace Lamp
c.
Troubleshooting
Install filters
d. Install Access Panel
e. Replace Ballast
Install Baffle Filter
Reinstall Baffle Filter
Install Charcoal Filter
Replace Charcoal Filter
Clean Baffle Filter
Adjust Vacuum switch only
Remove vacuum line kinks
Check voltage
Repair EAC
Clean EAC
Replace EAC power supply
Check voltage
Replace contact plate
Replace EAC module
Replace ionizer wire
Parts List
This section lists various parts that are available for replacement on the FSH2 FSH -2A, FSH -2A -99 and
FSH- 2A -99W
If you require assistance or need repairs please contact your area developer for a service agency in your
area For further assistance, please contact the Giles Enterprises, Inc. factory at the following phone
numbers.
IN THE UNITED STATES, CANADA or MEXICO
Please call 1- 800 288 -1555 during normal business hours, 8:00AM- 5:OOPM Central Time Zone. For emer-
gency equipment repair service, after normal business hours, call 1- 800 288 -1555, extension 314
IN ALL OTHER COUNTRIES
Please call 1- 334-272 -3528 during normal business hours, 8:OOAM- 5:OOPM Central Time Zone For emer-
gency equipment repair service, after normal business hours call, 1- 334-272 -3528 extension 314
INTERNET
Please visit our website on the world wide web at: www.ailesent.com
The goal of the Giles team of professionals is to provide you with the highest quality of service and assis-
tance You can help us accomplish this by obtaining the following information and having it readily avail-
able when calling. The information is recorded on the Serial Plate attached to the rear of the unit.
The area below may be helpful in recording information for use as a quick reference
Model:
Serial Number
Phase
Voltage:
Model: FSH -2, FSH- 2A -99,
FSH- 2A -99W
Serial Plate information
47
Model. FSH -2, FSH- 2A -99,
FSH- 2A -99W
Parts List
-Not shown
-UV Only
-Not shown and 1LS only
48
Parts List
7-
r: front Ve ntle Hoo
Item No Part No. Qty
Description
*1 90254 1 FILTER ACCESS PANEL, WELD ASSY (NON UV)
**1 90262 1 FILTER ACCESS PANEL, ASSY, FSH -2 -UV
2 20520 1 FILTER, EAC, 20 IN
3 30248 1 FILTER, CHARCOAL, ASSY, 20 X 12.375 X 2
*4 90226 1 LAMP ASSY 16-IN UV, REPLACEMENT ONLY
*5 23200 1 SWITCH SNAP ACTION ROLLER TYP
6 21125 1 BOARD CONTACT EAC, VH UNITS
7 30206 1 DRIP CUP WELD ASSY
8 34750 1 PIN DRIP CUP SAFETY
9 42300 1 FILTER, BAFFLE, 20X20 S /S, LARGE VH
10 24209 1 LED AIR FILTER, EAC
*11 23173 1 SWITCH MOMENTARY
12 22277 1 INDICATOR LIGHT GREEN
13 21190 1 SWITCH, ROCKER, ON -OFF 250V, 20A, DPST
14 64460 1 LABEL, CONTROL PANEL, FSH -2
15 38213 1 INDICATOR LIGHT ORANGE
16 38214 1 INDICATOR LIGHT RED
-Not shown
-UV Only
-Not shown and ILS only
Model: FSH -2, FSH- 2A -99,
FSH- 2A -99W
49
Model: FSH-2, FSH-2A-99,
FSH-2A-99W
,•7-•03.y•Wntles..lidod.-;Reaf
-Not shown
-UV Only
-Not shown, ILS only
50
(FSH-2A, FSH-2A-99,
and FSH-2A-99W)
Parts List
(FSH-2)
Parts List
Parts 'List for Ventless :Hood.: Rea!,.
Item No. Part No Qty
1 39272 1 TANK, 1.5 GAL. LABEL ASSY
*2 23778 1 SWITCH, SIDE ROTARY 240V, 30A, W/O ARM
*3 23779 1 ROD ADJUSTMENT
4 33589 1 BLOWER, ASSY, VH- FRYERS
5 46125 1 DAMPER, FIRE, 10 X 10 285 DEG LINK
6 24237 1 SWITCH PLUNGER, 250V 15A
7 23001 1 SWITCH VACUUM HOSE BARB
8 20002 1 SWITCH ANSUL, SHUTDOWN /ALARM 15A, 120V
9 40132 1 BRACKET RELEASE, ANSUL
10 23776 1 MODULE, AIR FILTER, ALARM AND SHUTDOWN
11 24208 1 POWER SUPPLY, W/DRIVER BRD 208- 240V,EAC
12 23751 1 TERMINAL BLOCK, MA106
13 23782 1 SONALERT 250V CONTINUOUS BEEP
14 22950 1 SONALERT 250V, INTERMITTENT
15 21191 1 RELAY 30A, 208V 2PL
15 21174 1 RELAY 30A, 240V 2PL
*16 20373 1 UV-LAMP ASSY (BALLSAT LAMP)
-Not shown
-UV Only
-Not shown, ILS only
Description
Model: FSH -2, FSH- 2A -99,
FSH- 2A -99W
51
Model: FSH -2, FSH- 2A -99,
FSH- 2A -99W
Notes:
52
Parts List
a�
F
N
a)
2
a)
0)
Co
a)
'C)
O
N
a-+
C
O
a)
O
a)
Sl
O
L
Co
a)
co
c
0
To
Q1
(n
a)
4-
a)
a)
to
a
0) N
Q
(*1
a-
m -0
LL Co
Model: FSH -2, FSH- 2A -99,
FSH- 2A -99W
54
8- Wiring Diagram FSH-2, FSH-2A, FSH- 2A -99W 208-240/60/1
i
Noy..
G
6
I
0
S 7
Wiring Diagram
WIRING DIAGRAM P/N
32353 -I
Wiring Diagram
s List for Wiring Diagram :ESN-2, .FSH -2A FSH 2A -99W 208-240/60/1
Item I Part No
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
21125
24208
23001
38215
23751
33589
24300
21190
24237
21174
32114
23776
23200
23782
22950
21182
24209
20002
20298
25275
38214
38213
Qty
1
1
1
1
1
1
2
P
1
1
1
1
1
1
1
1
1
1
1
1
1
2
1
1
Description
BOARD, CONTACT, EAC, VH UNITS
POWER SUPPLY, W/DRIVER BRD. 208- 240V.EAC
SWITCH, VACUUM, HOSE BARB
INDICATOR LIGHT, GREEN
TERMINAL BLOCK, MA106,6.POLE
BLOWER, ASSY, CF- 400VH, CF -500VH
BOX, 1/2° UTILITY
SWITCH, ROCKER, ON-Oft 250V,, 20A, DPST
SWITCH, PLUNGER, 250V, 15A
RELAY 30A, 240V, 2 POLE
BAFFLE FILTER SWITCH, ASSY, CF- 400/500VH
MODULE, AIR FILTER, ALARM AND SHUTDOWN
SWITCH, SNAP ACTION, ROLLER TYPE
SONALERT 250V, CONTINUOUS BEEP
SONALERT 250V, INTERMITTENT
SWITCH. PRESSURE, FIREBUTLER. 40PSI
LED, AIR FILTER, EAC
SWITCH, ANSUL, SHUTDOWN/ALARM, 15A, 120V
CONTACTOR
LOAD CENTER
BRAID. COPPER SHIELDING
WIRENUT IDEAL BLUE
INDICATOR LIGHT ORANGE
INDICATOR LIGHT, RED
Model: FSH -2, FSH- 2A -99,
FSH- 2A -99W
55
mm
I oa I tlQ
e0 1
Li
aan WAAL d
.r wa PO
0. MOO Peen
4 _oar n
WIRING DIAGRAM FSH -2, FSH -2A, FSH- 2A -99W 208- 240/60/1 W /ILS
MANUAL PUSH TO START AFTER POWER INTERRUPT
n
YLiesaaorrwMIL I
eam Poo
men MO
o 0Y-
u o o a- u
o
1 J L_ J®
m0e0M
Wiring Diagram
agram FSH -2 :FSH -2A, "FSH 2A -99W 268-240/60/1 w lL
Item Part No Qty Description
1 I 21125 1 1 I BOARD. CONTACT. EAC. VH UNITS
2 24208 1 POWER SUPPLY, WIDRIVER BRD, 208- 240V.EAC
3 23001 1 SWITCH, VACUUM, HOSE BARB
4 38275 7 INDICATOR LIGHT GREEN
5 23751 1 TERMINAL BLOCK MA106.6 POLE
6 33589 1 BLOWER, ASSY, CF -400VH, CF500VH
7 24300 2 BOX. 1/2° UTILITY
8 21190 1 SWITCH, ROCKER. ON -OFF, 250V, 20A, DPST
9 24237 1 SWITCH, PLUNGER, 250V. 15A
10 21174 1 RELAY, 30A, 240V, 2 POLE
11 32114 1 BAFFLE FILTER SWITCH, ASSY CF- 4001500VH
12 23776 1 MODULE, AIR FILTER, ALARM AND SHUTDOWN
13 23200 1 SWITCH, SNAP ACTION, ROLLER TYPE
14 23782 1 SONALERT, 250V, CONTINUOUS BEEP
15 22950 1 SONALERT, 250V. INTERMITTENT
16 21182 1 SWITCH, PRESSURE, FIREBUTLER, 40PSI
17 24209 1 LED, AIR FILTER, EAC
18 20002 1 SWITCH. ANSUL. SHUTDOWN /ALARM, 15A, 120V
19 1 CONTACTOR
20 1 LOAD CENTER
21 23173 1 SWITCH, PUSH BUTTON, MOMENTARY
22 20298 1 BRAID. COPPER SHIELDING
23 25275 2 WIRENUT, IDEAL BLUE
24 38214 1 INDICATOR LIGHT ORANGE
25 1 38213 I 1 INDICATOR LIGHT, RED
Model: FSH -2, FSH- 2A -99,
FSH- 2A -99W
57
7 -1
0+
WIRING DIAGRAM FSH-2, FSH-2A, FSH-2A-99W WITH UV 208-240/60/1
0
0 aim ea
01- IlUb 19 ON
Ifirti tat milf "11. ORM
Mal resa
rilicuOt
COM. Ma
C)
co
C
a
Wiring Diagram
8 P arts List for Wiring Diagram FSH 2,' FSH -2A, FSH 2A -99W 208-240/60/1 WI;UV:
Item I Part No Qty Description
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
21125
24208
23001
38215
23751
33589
24300
21190
24237
21174
32114
23776
23200
23782
22950
21182
24209
20002
20298
25275
38214
38213
25300
20373
90226
BOARD. CONTACT. EAC. VH UNITS
POWER SUPPLY, W/DRIVER BRD, 208- 240V.EAC
SWITCH, VACUUM, HOSE BARB
INDICATOR LIGHT GREEN
TERMINAL BLOCK, MA106.6 POLE
BLOWER, ASSY, CF -400VH, CF 500VH
BOX, 1/2° UTILITY
SWITCH, ROCKER, ON -OFF, 250V, 20A. DPST
SWITCH, PLUNGER, 250V, 15A
RELAY, 30A. 240V. 2 POLE
BAFFLE FILTER SWITCH, ASSY, CF- 400 /500VH
MODULE, AIR FILTER, ALARM AND SHUTDOWN
SWITCH, SNAP ACTION, ROLLER TYPE
SONALERT 250V. CONTINUOUS BEEP
SONALERT, 250V. INTERMITTENT
SWITCH, PRESSURE, FIREBUTLER, 40PSI
LED, AIR FILTER, EAC
SWITCH, ANSUL. SHUTDOWN /ALARM, 15A. 120V
CONTACTOR
LOAD CENTER
BRAID. COPPER SHIELDING
WIRENUT, IDEAL BLUE
INDICATOR LIGHT ORANGE
INDICATOR LIGHT, RED
WIRENUT, ORANGE
UV -LAMP ASSY (BALLAST AND LAMP)
LAMP ASSY 16-IN, UV REPLACEMENT ONLY
Model: FSH -2, FSH- 2A -99,
FSH- 2A -99W
59
p
9
9
O
��yM�•- r KW M00
0
�---Ia WO MIIMO
r .-10 8 Wt. 0000
si
O
O— ONO AIM
r
-1
n
0pat wS"
0 r
WIRING DIAGRAM FSH -2, FSH -2A, FSH- 2A -99W WITH UV /ILS 208 240/60/1
MANUAL PUSH /HOLD TO START AFTER POWER INTERRUPT
0
a
en wm ua u roe
ft -11011110. 0:001 rglee
V
Wiring Diagram
arts List: for Wiring Diagram
FSH -2,,' FSH -2A, &:FSH -2A99W 208 240/60/1 wf U:V &'ILS.
Item 1 Part No ,j Qty 1 Description
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
21125 1 I BOARD, CONTACT EAC, VH UNITS
24208 1 1 POWER SUPPLY, W /DRIVER BRO. 208-240V,EAC
23001 1 1 SWITCH, VACUUM. HOSE BARB
38215 1 INDICATOR LIGHT, GREEN
23751 1 TERMINAL BLOCK. MA106.6 POLE
33589 1 BLOWER. ASSY. CF- 400VH. CF-500VH
24300 2 BOX 1/2° UTILITY
21190 1 SWITCH, ROCKER, ON -OFF 250V, 20A, DPST
24237 1 SWITCH, PLUNGER. 250V. 15A
21174 1 RELAY, 30A, 240V, 2 POLE
32114 1 BAFFLE FILTER SWITCH, ASSY CF- 4400/500VH
23776 1 MODULE, AIR FILTER. ALARM AND SHUTDOWN
23200 1 SWITCH, SNAP ACTION, ROLLER TYPE
23782 1 SONALERT, 250V, CONTINUOUS BEEP
22950 1 SONALERT, 250V. INTERMITTENT
21182 1 SWITCH, PRESSURE, FIREBUTLER, 40PSI
24209 1 LED, AIR FILTER, EAC
20002 1 SWITCH, ANSUL. SHUTDOWN /ALARM, 15A, 120V
1 CONTACTOR
1 LOAD CENTER
20298 1 BRAID, COPPER SHIELDING
25275 2 WIRENUT, BLUE
38214 1 LIGHT. INDICATOR, RED
38213 1 LIGHT INDICATOR. ORANGE
25300 1 WIRENUT ORANGE
20373 1 UV -LAMP ASSY (BALLAST AND LAMP)
90226 1 LAMP ASSY, 16-IN. UV, REPLACEMENT ONLY
23173 I 1 SWITCH, PUSH BUTTON, MOMENTARY
Model: FSH -2, FSH- 2A -99,
FSH- 2A -99W
61
FSN -f i FSH.2A-99r
N
FSH SOw
Vdiring Diagram
DIA GRAM PIS
WIRING DIAGRAM
Wiring Diagram
List for Wiring Diagram FSH -99 ONLY 208-240/60/1
Item Part No I Qty
01 I 21125 1
02 24208 1
03 23001 1
04 38215
05 23751 1
06 33589 1
07 32208 2
08 21190 1
09 24237 1
10 20370 1
11 32114 1
12 23776 1
13 23200 1
14 23782 1
15 22950 1
16 21182 1
17 24209 1
18 20002 1
19 21900 1
20 21950 1
21 20298 1
22 25275 1
23 38214 1
24 38213 1
25 20303 1
26 20304 1
27 20319 1
28 20320 1
Description
BOARD, CONTACT, EAC, VH UNITS
POWER SUPPLY, W/DRIVER BRD, 208- 240V.EAC
SWITCH, VACUUM, HOSE BARB
INDICATOR LIGHT GREEN
TERMINAL BLOCK, MA106,6 POLE
BLOWER, ASSY, CF- 400VH, CF 500VH
CONTACTOR, ASSY, 208/24OVAC, 3PH
SWITCH, ROCKER, ON -OFF 250V, 20A, DPST
SWITCH, PLUNGER, 250V, i5A
RECEPTACLE, 50A 3PH, 4 WIRE
BAFFLE FILTER SWITCH, ASSY, CF- 400 /500VH
MODULE, AIR FILTER, ALARM AND SHUTDOWN
SWITCH, SNAP ACTION, ROLLER TYPE
SONALERT 250V, CONTINUOUS BEEP
SONALERT 250V, INTERMITTENT
SWITCH, PRESSURE, FIREBUTLER, 40PSI
LED, AIR FILTER, EAC
SWITCH, ANSUL, SHUTDOWN/ALARM, 15A, 120V
FUSE, 15 -AMP SC 15
HOLDER, FUSE, 300V, 15A SC OTO 15
BRAID, COPPER SHIELDING
WIRENUT, IDEAL BLUE
INDICATOR LIGHT, ORANGE
INDICATOR LIGHT. RED
TERMINAL BLOCK, 4-12 GA WIRE
TERMINAL BLOCK, GROUND, 4-12 GA WIRE
TERMINAL BLOCK 50 AMP AWG 8-24
TERMINAL BLOCK, GROUND, AWG 8-24
Model: FSH -2, FSH- 2A -99,
FSH- 2A -99W
63
FSH 2. fSH 99.
FSH -2A-
41-
Wiring Diagram
'VT
CO
a,
01
1
g
0
0
z
a
DIAGRAM PIN
WIRING DIAGRAM
Wiring Diagram
List for Wiring Diagram FSH 2A- 99.ONLY 208-240/6011 w /.ILS
Item
01
02
03
04
05
06
07
08
09
10
71
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
Part No Qty.
21125
24208
23001
38215
23751
33589
32208
21190
24237
20370
32774
23776
23200
23782
22950
21182
24209
20002
21900
21950
20298
25275
38214
38213
20303
20304
20319
20320
23173
21174
Description
BOARD, CONTACT, EAC, VH UNITS
POWER SUPPLY, W /DRIVER BRD, 208- 240V,EAC
SWITCH, VACUUM, HOSE BARB
INDICATOR LIGHT. GREEN
TERMINAL BLOCK, MA106,6 POLE
BLOWER, ASSY,, CF- 400VH. CF 500VH
CONTACTOR, ASSY, 208/240VAC. 3PH
SWITCH, ROCKER. ON -OFF 250V, 20A, DPST
SWITCH, PLUNGER, 250V i5A
RECEPTACLE. 50A, 3PH, 4 WIRE
BAFFLE FILTER SWITCH, ASSY CF- 400/500VH
MODULE, AIR FILTER. ALARM AND SHUTDOWN
SWITCH, SNAP ACTION, ROLLER TYPE
SONALERT 250V, CONTINUOUS BEEP
SONALERT, 250V, INTERMITTENT
SWITCH, PRESSURE, FIREBUTLER, 40PSI
LED, AIR FILTER. EAC
SWITCH. ANSUL. SHUTDOWN /ALARM, 15A. 120V
FUSE, 15-AMP SC -15
HOLDER, FUSE, 300V. 15A, SC OTO 15
BRAID. COPPER SHIELDING
WIRENU, IDEAL BLUE
INDICATOR LIGHT ORANGE
INDICATOR LIGHT RED
TERMINAL BLOCK, 4-12 GA WIRE
TERMINAL BLOCK, GROUND, 4-12 GA WIRE
TERMINAL BLOCK. 50 AMP. AWG 8-24
TERMINAL BLOCK, GROUND. AWG 8-24
SWITCH, PUSH BUTTON, MOMENTARY
RELAY, 30A, 240V, 2PL
Model: FSH -2, FSH- 2A -99,
FSH- 2A -99W
65
fez
q0 t e a
—G
W 208- 240/60/3
M W /PLUG A
WIR�NO 0000M F94-2A-99
Wiring Diagram
Parts List for Winng Diagram FSH -2A -99 ONLY 208-240/60/1 virI "U'
Item Part No I Qty Description
01 21125 I 1
02 24208 1
03 23001 1
04 38215 1
05 23751 1
06 33589 1
07 32208 2
08 21190 1
09 24237 1
10 20370 1
11 32114
12 23776 1
13 23200 1
14 23782 1
15 22950 1
16 21182 1
17 24209 1
18 20002 1
19 21900 1
20 21950 1
21 20298 1
22 25275 1
23 38214 1
24 38213 1
25 20303 3
26 20304 2
27 20319 2
28 20320 1
29 20304 2
30 20373 1
31 90226 I 1
BOARD, CONTACT EAC, VH UNITS
POWER SUPPLY, W /DRIVER BRD, 208- 240V,EAC
SWITCH, VACUUM, HOSE BARB
INDICATOR LIGHT GREEN
TERMINAL BLOCK, MA106,6 POLE
BLOWER, ASSY, CF- 400VH, CF500VH
CONTACTOR, ASSY, 208/240VAC, 3PH
SWITCH, ROCKER, ON -OFF, 250V. 20A, DPST
SWITCH, PLUNGER, 250V, 15A
RECEPTACLE, 50A. 3PH, 4 WIRE
BAFFLE FILTER SWITCH. ASSY CF- 400/500VH
MODULE, AIR FILTER, ALARM AND SHUTDOWN
SWITCH, SNAP ACTION, ROLLER TYPE
SONALERT, 250V, CONTINUOUS BEEP
SONALERT 250V, INTERMITTENT
SWITCH, PRESSURE, FIREBUTLER, 40PSI
LED, AIR FILTER. EAC
SWITCH, ANSUL, SHUTDOWN /ALARM, 15A, 120V
FUSE, 15 -AMR SC 15
HOLDER. FUSE. 300V, 15A. SC OTO 15
BRAID, COPPER SHIELDING
WIRENUT, IDEAL BLUE
INDICATOR LIGHT. ORANGE
INDICATOR LIGHT, RED
TERMINAL BLOCK, 4-12 GA WIRE
TERMINAL BLOCK. GROUND. 4-12 GA WIRE
TERMINAL BLOCK, 50 AMP AWG 8-24
TERMINAL BLOCK. GROUND. AWG 8-24
TERMINAL BLOCK, GROUND, 4-12 GA WIRE
UV -LAMP ASSY (BALLAST AND LAMP)
LAMP ASSY, 16-IN, UV, REPLACEMENT ONLY
Model: FSH -2, FSH- 2A -99,
FSH- 2A -99W
67
ASH 2t fS H- 21k-99,
Mo W
fSH -2�► g
�F 4
J
,ring Diagram
i
M PIN.
IRING9 p&
Wiring Diagram
Model: FSH -2, FSH- 2A -99,
FSH- 2A -99W
Item Part No. ,y Qty Description
01 21125 I 1
02 24208 1
03 23001 I 1
04 38215 1
05 23751 1
06 33589 1
07 32208 2
08 21190 1
09 24237 1
10 20370 1
11 32114 1
12 23776 1
13 23200 1
14 23782 1
15 22950 1
16 21182 1
17 24209 1
18 20002 1
19 21900 1
20 21950 1
21 20298 1
22 25275 1
23 38214 1
24 38213 1
25 20303 1
26 20304 1
27 20319 1
28 20320 1
29 20304 1
30 20373 1
31 90226 1
32 23173 1
33 21174 1
BOARD, CONTACT EAC, VH UNITS
POWER SUPPLY, W /DRIVER BRD, 208- 240V,EAC
SWITCH, VACUUM, HOSE BARB
INDICATOR LIGHT, GREEN
TERMINAL BLOCK, MA106.6 POLE
BLOWER, ASSY, CF- 400VH, CF500VH
CONTACTOR, ASSY, 208/240VAC. 3PH
SWITCH, ,ROCKER, ON -OFF, 250V, 20A, DPST
SWITCH, PLUNGER, 250V. 15A
RECEPTACLE. 50A. 3PH. 4 WIRE
BAFFLE FILTER SWITCH, ASSY CF- 4001500VH
MODULE, AIR FILTER, ALARM AND SHUTDOWN
SWITCH. SNAP ACTION. ROLLER TYPE
SONALERT, 250V, CONTINUOUS BEEP
SONALERT, 250V, INTERMITTENT
SWITCH, PRESSURE. FIREBUTLER. 40PSI
LED, AIR FILL ER. EAC
SWITCH, ANSUL, SHUTDOWN /ALARM, 15A, 120V
FUSE, 15-AMP SC 15
HOLDER, FUSE, 300V, 15A, SC OTO 15
BRAID, COPPER SHIELDING
WIRENUT, IDEAL BLUE
INDICATOR LIGHT, ORANGE
INDICATOR LIGHT RED
I ERMINAL BLOCK, 4 -12 GA WIRE
TERMINAL BLOCK, GROUND, 4-12 GA WIRE
TERMINAL BLOCK, 50 AMP AWG 8-24
TERMINAL BLOCK, GROUND, AWG 8-24
TERMINAL BLOCK, GROUND, 4-12 GA WIRE
UV -LAMP ASSY (BALLAST AND LAMP)
LAMP ASSY. 16-IN, .UV, REPLACEMENT ONLY
SWITCH, PUSH BUTTON, MOMENTARY
RELAY, 30A, 240V, 2PL
69
Model: FSH -2, FSH- 2A -99,
FSH- 2A -99W
'8- `Parts List fog FSH-2A-99, Wiring Diagram FSH-2, FSH-2A, FSH -2A 99, &FSH- 2A -99W 220/50/1
70
I
I ®t4 21_1__
Wiring Diagram
a
WIRING DIAGRAM P/N
36306 -E
Wiring Diagram
s "List for Winn
iagram >'FSH -2, FSH-2A, FSH -2A =99
FSH 2A- .99W.220/50/1
Item I Part No I Qty 1 Description
1 21125 1
2 24208 1
3 23001 1
4 38215 1
5 23751 1
6 33589 1
7 24300 2
8 21190 1
9 24237 1
10 21174 1
11 32114 1
12 23776 1
13 23200 1
14 23782 1
15 22950 1
16 21182 1
17 24209 1
18 20002 1
19 1
20 1
21 20298 1
22 25275 1
23 38214 1
24 38213 1
BOARD, CONTACT EAC, VH UNITS
POWER SUPPLY, W/DRIVER BRD, 208- 240V,EAC
SWITCH, VACUUM, HOSE BARB
INDICATOR LIGHT GREEN
TERMINAL BLOCK, MA106,6 POLE
BLOWER, ASS'Y', CF-400VH, CF 500VH
BOX, 1/2° UTILITY
SWITCH, ROCKER, ON -OFF 250V, 20A, DPST
SWITCH, PLUNGER, 250V, 15A
RELAY, 30A, 240V, 2 POLE
BAFFLE FILTER SWITCH, ASSY CF- 400/500VH
MODULE, AIR FILTER, ALARM AND SHUTDOWN
SWITCH, SNAP ACTION, ROLLER TYPE
SONALERT, 250V, CONTINUOUS BEEP
SONALERT 250V, INTERMITTENT
SWITCH, PRESSURE, FIREBUTLER, 40PSI
LED, AIR FILTER, EAC
SWITCH, ANSUL, SHUTDOWN /ALARM, 15A, 120V
CONTACTOR
LOAD CENTER
BRAID, COPPER SHIELDING
WIRENUT, IDEAL BLUE
INDICATOR LIGHT, RED
INDICATOR LIGHT ORANGE
Model: FSH -2, FSH- 2A -99,
FSH- 2A -99W
71
Model- FSH -2, FSH- 2A -99,
FSH- 2A -99W
Notes:
72
Wiring Diagram
GLem
FOODSERVICE EQUIPMENT
Giles Enterprises, Inc.
P.O Box 210247 2750 Gunter Park Drive West Monigcrinery. Al 36121-0247 USA
(334) 272-1457 3— Hotline 1-800 Canada Only) FAX (334) 272 3561 www.gilesent.com
Form No. 60200 (Release dm: 07198)(Rmision ()me: 01128109)(Rev F)