PREPARED 7/27/11 8 10 52 INSPECTION TICKET
CITY OF PORT ANGELES INSPECTOR JAMES LIERLY
ADDRESS 1933 VILLAGE CIR SUBDIV
TENANT NBR RANDA L MAXHIMER
CONTRACTOR PHONE
OWNER RANDA L MAXHIMER PHONE
PARCEL 06 30 13 5 7 0110 0000
APPL NUMBER 10 00000508 RES NEW SFR
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
12/02/10 AP December 1 2010 3 56 35 PM 1pangrle
BRUCE 912 0079
DOWNSPOUT DRAINS
December 2 2010 4 16 30 PM jlierly
March 3 2011 3 18 01 PM jlierly
BL9 01 1/25/11 JLL BLDG SHEARWALL TIME 01 00
1/25/11 AP January 25 2011 8 19 46 AM 1pangrle
BRUCE 912 0079
EXTERIOR SHEAR NAILING
AFTERNOON
January 25 2011 4 40 23 PM jlierly
BAIR 01 3/03/11 JLL BLDG AIR SEAL TIME 01 00
3/03/11 AP March 2 2011 1 43 49 PM 1pangrle
BRUCE 912 0079
AIRSEAL
AFTERNOON
December 2 2010 4 16 30 PM jlierly
March 3 2011 3 18 01 PM jlierly
March 9 2011 8 24 15 AM 1pangrle
March 9 2011 8 24 51 AM 1pangrle
March 9 2011 8 26 42 AM 1pangrle
BL3 02 3/03/11 JLL BLDG FRAMING TIME 01 00
3/03/11 AP March 2 2011 1 44 37 PM 1pangrle
BRUCE 912 0079
FRAMING
AFTERNOON
December 2 2010 4 16 30 PM jlierly
March 3 2011 3 18 01 PM jlierly
March 9 2011 8 45 39 AM 1pangrle
BLI 01 3/09/11 JLL BLDG INSULATION
3/09/11 AP March 9 2011 8 47 47 AM 1pangrle
March 9 2011 4 51 59 PM jlierly
BLDR 01 3/23/11 JLL BLDG DRYWALL IBWP TIME 09 00
3/23/11 AP March 22 2011 4 06 13 PM 1pangrle
BRUCE 912 0079
IBWP
HE PREFERS A MORNING INSPECTION
March 23 2011 4 14 51 PM jlierly
PW99 01 7/19/11 RV PUBLIC WORKS FINAL
7/19/11 AP July 20 2011 7 23 23 AM rvess
July 20 2011 7 23 44 AM rvess
BL99 01 7/27/11 JLL BLDG FINAL
7 July 26 2011 9 20 47 AM 1pangrle
I
J p l BRUCE 912 0079
1 BUILDING FINAL
PERMIT ME 00 MECHANICAL PERMIT
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
CONTINUED ONTO NEXT PAGE
PAGE 2
DATE 7/27/11
PREPARED 7/27/11 8 10 52 INSPECTION TICKET PAGE 3
CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 7/27/11
ADDRESS 1933 VILLAGE CIR SUBDIV
TENANT NBR RANDA L MAXHIMER
CONTRACTOR PHONE
OWNER RANDA L MAXHIMER PHONE
PARCEL 06 30 13 5 7 0110 0000
APPL NUMBER 10 00000508 RES NEW SFR
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
ME99 01 7/27/11 JLL MECHANICAL JulyA2ICAL 1INAL
July 26 2011 9 21 03 AM 1pangrle
4-1 BRUCE 912 0079
MECHANICAL FINAL
PERMIT
TYP /SQ
PL 00 PLUMBING PERMIT
REQUESTED INSP DESCRIPTION
COMPLETED RESULT RESULTS /COMMENTS
PL6 01 12/02/10 JLL PLUMBING WATER SUPPLY
12/02/10 AP December 1 2010 3 57 44 PM 1pangrle
BRUCE 912 0079
WATER SUPPLY LINE METER TO BLDG
December 2 2010 4 16 30 PM jlierly
PL2 01 2/01/11 JLL PLUMBING ROUGH IN TIME 01 00
2/01/11 AP January 31 2011 3 23 13 PM 1pangrle
JOHN 460 6902
ROUGH IN PLUMBING
AFTERNOON
February 1 2011 4 05 04 PM jlierly
March 9 2011 8 25 05 AM 1pangrle
March 9 2011 8 27 52 AM 1pangrle
March 9 2011 8 46 15 AM 1pangrle
PL99 01 7/27/11 JLL A PLUMBING FINAL
July 26 2011 9 21 24 AM 1pangrle
BRUCE 912 0079
PLUMBING FINAL
COMMENTS AND NOTES
PREPARED 3/23/11 8 05 36 INSPECTION TICKET
CITY OF PORT ANGELES INSPECTOR JAMES LIERLY
ADDRESS 1933 VILLAGE CIR SUBDIV
TENANT NBR RANDA L MAXHIMER
CONTRACTOR PHONE
OWNER RANDA L MAXHIMER PHONE
PARCEL 06 30 13 5 7 0110 0000
APPL NUMBER 10 00000508 RES NEW SFR
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
12/02/10 AP December 1 2010 3 56 35 PM 1pangrle
BRUCE 912 0079
DOWNSPOUT DRAINS
December 2 2010 4 16 30 PM jlierly
March 3 2011 3 18 01 PM jlierly
BL9 01 1/25/11 JLL BLDG SHEARWALL TIME 01 00
1/25/11 AP January 25 2011 8 19 46 AM 1pangrle
BRUCE 912 0079
EXTERIOR SHEAR NAILING
AFTERNOON
January 25 2011 4 40 23 PM jlierly
BAIR 01 3/03/11 JLL BLDG AIR SEAL TIME 01 00
3/03/11 AP March 2 2011 1 43 49 PM 1pangrle
BRUCE 912 0079
AIRSEAL
AFTERNOON
December 2 2010 4 16 30 PM jlierly
March 3 2011 3 18 01 PM jlierly
March 9 2011 8 24 15 AM 1pangrle
March 9 2011 8 24 51 AM 1pangrle
March 9 2011 8 26 42 AM 1pangrle
BL3 02 3/03/1 JLL BLDG FRAMING TIME 01 00
3/03/11 AP March 2 2011 1 44 37 PM 1pangrle
BRUCE 912 0079
FRAMING
AFTERNOON
December 2 2010 4 16 30 PM jlierly
March 3 2011 3 18 01 PM jlierly
March 9 2011 8 45 39 AM 1pangrle
BLI 01 3/09/11 JLL BLDG INSULATION
3/09/11 AP March 9 2011 8 47 47 AM 1pangrle
March 9 2011 4 51 59 PM jlierly
BLDR 01 3/23/11 L BLDG DRYWALL IBWP TIME 09 00
March 22 2011 4 06 13 PM 1pangrle
BRUCE 912 0079
IBWP
HE PREFERS A MORNING INSPECTION
COMMENTS AND NOTES
PAGE 2
DATE 3/23/11
PREPARED 3/09/11 9 13 34 INSPECTION TICKET
CITY OF PORT ANGELES INSPECTOR JAMES LIERLY
ADDRESS 1933 VILLAGE CIR SUBDIV
TENANT NOR RANDA L MAXHIMER
CONTRACTOR PHONE
OWNER RANDA L MAXHIMER PHONE
PARCEL 06 30 13 5 7 0110 0000
APPL NUMBER 10 00000508 RES NEW SFR
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
12/02/10 AP December 1 2010 3 56 35 PM 1pangrle
BRUCE 912 0079
DOWNSPOUT DRAINS
December 2 2010 4 16 30 PM jlierly
March 3 2011 3 18 01 PM jlierly
BL9 01 1/25/11 JLL BLDG SHEARWALL TIME 01 00
1/25/11 AP January 25 2011 8 19 46 AM 1pangrle
BRUCE 912 0079
EXTERIOR SHEAR NAILING
AFTERNOON
January 25 2011 4 40 23 PM lierly
BAIR 01 3/03/11 JLL BLDG AIR SEAL TIME 01 00
3/03/11 AP March 2 2011 1 43 49 PM 1pangrle
BRUCE 912 0079
AIRSEAL
AFTERNOON
December 2 2010 4 16 30 PM jlierly
March 3 2011 3 18 01 PM jlierly
March 9 2011 8 24 15 AM 1pangrle
March 9 2011 8 24 51 AM 1pangrle
March 9 2011 8 26 42 AM 1pangrle
BL3 02 3/03/11 JLL BLDG FRAMING TIME 01 00
3/03/11 AP March 2 2011 1 44 37 PM 1pangrle
BRUCE 912 0079
FRAMING
AFTERNOON
December 2 2010 4 16 30 PM jlierly
March 3 2011 3 18 01 PM jlierly
March 9 2011 8 45 39 AM 1pangrle
BLI 01 3/09/11 i,l, BLDG INSULATION
March 9 2011 8 47 47 AM 1pangrle
COMMENTS AND NOTES
PAGE 8
DATE 3/09/11
PREPARED 3/03/11 8 05 25 INSPECTION TICKET PAGE 2
CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 3/03/11
ADDRESS 1933 VILLAGE CIR SUBDIV
TENANT NBR RANDA L MAXHIMER
CONTRACTOR PHONE
OWNER RANDA L MAXHIMER PHONE
PARCEL 06 30 13 5 7 0110 0000
APPL NUMBER 10 00000508 RES NEW SFR
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
12/02/10 AP December 1 2010 3 56 35 PM 1pangrle
BRUCE 912 0079
DOWNSPOUT DRAINS
December 2 2010 4 16 30 PM jlierly
BL9 01 1/25/11 JLL BLDG SHEARWALL TIME 01 00
1/25/11 AP January 25 2011 8 19 46 AM 1pangrle
BRUCE 912 0079
EXTERIOR SHEAR NAILING
AFTERNOON
January 25 2011 4 40 23 PM jlierly
3/03/11 (NLL BLDG AIR SEAL TIME 01 00
BAIR 01
March 2 2011 1 43 49 PM 1pangrle
BRUCE 912 0079
AIRSEAL
AFTERNOON
BL3 02 3/03/11 L BLDG FRAMING TIME 01 00
March 2 2011 1 44 37 PM 1pangrle
BRUCE 912 0079
FRAMING
AFTERNOON
COMMENTS AND NOTES
PREPARED 2/01/11 8 45 39 INSPECTION TICKET PAGE 2
CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 2/01/11
ADDRESS 1933 VILLAGE CIR SUBDIV
TENANT NBR RANDA L MAXHIMER
CONTRACTOR PHONE
OWNER RANDA L MAXHIMER PHONE
PARCEL 06 30 13 5 7 0110 0000
APPL NUMBER 10 00000508 RES NEW SFR
PERMIT PL 00 PLUMBING PERMIT
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
PL6 01 12/02/10 JLL
12/02/10 AP
PL2 01 2/01/11
t
V
PLUMBING WATER SUPPLY
December 1 2010 3 57 44 PM 1pangrle
BRUCE 912 0079
WATER SUPPLY LINE METER TO BLDG
December 2 2010 4 16 30 PM jlierly
PLUMBING ROUGH IN TIME 01 00
January 31 2011 3 23 13 PM 1pangrle
JOHN 460 6902
ROUGH IN PLUMBING
AFTERNOON
COMMENTS AND NOTES
Application Number
Application pin number
Property Address
ASSESSOR PARCEL NUMBER
Tenant nbr name
Application type description
Subdivision Name
Property Use
Property Zoning
Application valuation
Application desc
INSTALL A FIRE SPRINKLER SYSTEM
Owner
CITY OF PORT ANGELES
FIRE DEPARTMENT PERMIT
321 East 5t Street, Port Angeles, WA 98362
11 00000078
938252
1933 VILLAGE CIR
06 30 13 5 7 0110 0.000
RANDA L MAXHIMER
FIRE SPRINKLER SYSTEM
RESIDENTIAL HIGH DENSITY
1875
Contractor
Date 1/27/11
RANDA L MAXHIMER INNOVATED FIRE SPRINKLERS
582 KEMP ST 81 NEW HAVEN LANE
PORT ANGELES WA 98362 PORT ANGELES
(360) 452_7583
Structure Information 000 000 FIRE SPRINKLER SYSTEM
Permit
Additional desc
Permit pin number
Permit Fee
Issue Date
Expiration Date
Fee summary
Permit Fee Total
Plan Check Total
Grand Total
WA 98362
FIRE SPRINKLER RESIDENTIAL
FIRE SPRINKLER SYSTEM
180711
00 Plan Check Fee 00
1/27/11 Valuation 1875
7/26/11
Special Notes and Comments
A full acceptance te will be required for the fire
sprinkler system
Call for cover inspection for -all sprinkler installations
Charged Paid Credited
00 00 00
00 00 00
00 00 00
Due
00
00
00
REPORT SALES TAX
on your state excise tax form
to the City of Port Angeles
(Location Code 0502)
This permit becomes null and void if work authorized is not commenced within 180 days, if work is suspended or
abandoned for a period of 180 days afer the work has commenced, or if required inspections have not been requested with
180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be
true and correct. All provisions of recognized standards, laws and ordinances governing this type of work will be compled
with whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel
the provisions of any state or local law regulating the work specified in the permit.
A Piz lag/lc
Signature of.Contractor or- AutlCrized_Agent Date Signature of Owner Of Owner is builder)
Date 'r
GENERAL COMMENTS
FIRE PERMIT INSPECTION RECORD
Call 360-417-4655 for fire inspections. Please provide a minimum 24 -hour notice It is unlawful to cover insulate
or conceal any work before inspected and accepted. Post permit in a conspicuous location.
KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE
Inspection Type I Date Passed
FIRE SPRINKLER
Underground piping hydrostatically tested
Underground piping flushed
Interior piping hydrostatically tested
Interior piping inspection
Dry system air tested at 40 psi (24 hours)
Sprinkler final Z�_4 kbd
FIRE ALARM
Rough -in inspection
Alarm final
LP -GAS
Underground piping inspection/pressure test
Above ground piping inspection/pressure test
Tank (container) inspection
Appliance inspection
LP -gas final
UNDERGROUND STORAGE TANK (UST) ABANDONMENT
Removal of flammable /combustible liquids
Tank appropriately abandoned
UST abandonment final
I PERMIT OTHER (specify)
permit final
Test #1
Piping pressure test
Time initiated
Test #2
Piping pressure test
Time initiated
Comments
Completed by Contractor
psi
psi
7.1
PREPARED 1/25/11 8 26 59 INSPECTION TICKET PAGE 5
CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 1/25/11
ADDRESS 1933 VILLAGE CIR SUBDIV
TENANT NBR RANDA L MAXHIMER
CONTRACTOR PHONE
OWNER RANDA L MAXHIMER PHONE
PARCEL 06 30 13 5 7 0110 0000
APPL NUMBER 10 00000508 RES NEW SFR
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
12/02/10 AP December 1 2010 3 56 35 PM 1pangrle
BRUCE 912 0079
DOWNSPOUT DRAINS
December 2 2010 4 16 30 PM jlierly
BL9 01 1/25/11 JLL S BLDG SHEARWALL TIME 01 00
January 25 2011 8 19 46 AM 1pangrle
BRUCE 912 0079
EXTERIOR SHEAR NAILING
AFTERNOON
COMMENTS AND NOTES
rrr
Project Type Brief Des
Check all that apply
?idNew Construction
o Addition
o Remodel
Repair
Re -roof
Demolition
o Sign
o Heat System
Other
Floor Areas
Basement
1 S1 Floor
2 Floor
3 Floor
Garage
Carport
Covered Porch
Deck
Shed
Other
Max height of proposed structures
Will a lawn sprinkler system be installed?
Will a fire sprinkler system be installed?
BUILDING PERMIT APPLICATION Print in ink
CITY OF PORT ANGELES
Attn Building Permit Technician
321 E. Fifth St. Port Angeles WA 98362
(360) 417 -4815 fax (360) 417 -4711
Applicant or Agent ,�cQ C, Q v
Owner Ck..0 v d 0. t C
Owner's Address 5 2 j-( -e„ vt-. S
Contractor/Engineer //JN( a, T /7 /R F
Contractor /Engineer's Address a/ >tc a/ e_
License /A/Ci1),C,5'O 1.--L
PROJECT ADDRESS 3 V j/ cL c
v
Parcel Number
Existing (sq. ft.) Proposed (so. ft.)
Total footprint of structures sq ft. Lot size
Phone
Phone
Phone
Expires
For City Use Only
Date Received 0 -10— t
Permit i1 -lcX
Date Approved
&//z,//
Lot I Zoning
per sq ft.
ft. Occupancy group of bedrooms
Occupant load of full baths
Construction type of half baths
3
L- 1S2 -7S�'�
AND
criotion. ,Residential o Commercial o Multi family Industrial
wall- mounted projecting freestanding awning other
Total sign area sq ft. Maximum allowed sign area so ft.
o Heat pump o wood- burning stove gas fireplace pellet stove other
TOTAL VALUATION g �6 6-
sq ft. Lot coverage
I have read and.completed this application and know it to he true and correct. l am authorized to apply 'or this permit and
understand that it is my responsibility to determine what permits are required and io obtain permits prior to working on
Date Print Name 1 `I 1 2
projects.
T Form /Building Division /Bldg Permit Appl. -2006 Code doc
Application Number
Application pin number
Property Address
ASSESSOR PARCEL NUMBER
Application type description
Subdivision Name
Property Use
Property Zoning
Application valuation
Application desc
New home
Owner
RANDA L MAXHIMER
582 KEMP ST
PORT ANGELES
Qty
1 00
1 00
Permit Fee Total
Plan Check Total
Grand Total
WA 98362
Permit
Additional desc
Permit pin number 178384
Permit Fee 145 50
Issue Date 12/03/10
Expiration Date 6/01/11
Unit Charge Per
110 3000 ECH
35 2000 ECH
Fee summary Charged
145 50
00
145 50
Signature of owner or Electrical Contractor X
ELECTRICAL PERMIT
CITY OF PORT ANGELES
360 417 -4735
10 00001411
853242
1933 VILLAGE CIR
06 30 13 5 7 0110 0000
ELECTRICAL ONLY
RESIDENTIAL HIGH DENSITY
0
Contractor
ELECTRICAL NEW RESIDENTIAL
INSPECTION TYPE DATE
DITCH
SERVICE
ROUGH IN
FINAL
COMMENTS
PERMIT WILL EXPIRE SIX (6) MONTHS FROM LAST INSPECTION
OLYMPIC WIRING INC
9601 PROVOST ROAD NW
SILVERDALE WA 98383
(360) 692 0134
Plan Check Fee
Valuation
EL R SQFT FIRST 1300
EL R SQFT ADDITIONAL 500
Paid Credited
145 50 00
00 00
145 50 00
Date 12/03/10
RESULTS
00
0
Extension
110 30
35 20
Due
00
00
00
REPORT STATE SALES TAX
on your excise tax form
to the City of Port Angeles
(Location Code 0502)
INSPECTOR.
Date.
PREPARED 12/02/10 8 18 51 INSPECTION TICKET PAGE 8
CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 12/02/10
ADDRESS 1933 VILLAGE CIR SUBDIV
TENANT NBR RANDA L MAXHIMER
CONTRACTOR PHONE
OWNER RANDA L MAXHIMER PHONE
PARCEL 06 30 13 5 7 0110 0000
APPL NUMBER 10 00000508 RES NEW SFR
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
BRUCE 912 0079
DOWNSPOUT DRAINS
PERMIT PL 00 PLUMBING PERMIT
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
PL6 01 12/02/10 JLL PLUMBING WATER SUPPLY
December 1 2010 3 57 44 PM 1pangrle
'i BRUCE 912 0079
WATER SUPPLY LINE METER TO BLDG
COMMENTS AND NOTES
PREPARED 12/02/10 8 18 51 INSPECTION TICKET PAGE 7
CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 12/02/10
ADDRESS 1933 VILLAGE CIR SUBDIV
TENANT NBR RANDA L MAXHIMER
CONTRACTOR PHONE
OWNER RANDA L MAXHIMER PHONE
PARCEL 06 30 13 5 7 0110 0000
APPL NUMBER 10 00000508 RES NEW SFR
PERMIT BPR 00 BUILDING PERMIT RESIDENTIAL
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
BL1 01 11 /10 /10 JLL BLDG FOUNDATION FOOTING TIME 09 00
11 /10 /10 AP November 9 2010 3 59 04 PM 1pangrle
BRUCE 912 0079
FOOTINGS
HE REQUESTED THE EARLIEST POSSIBLE MORNING INSPECTION SO
THEY CAN POUR TODAY
November 10 2010 4 36 53 PM jlierly
BL2 01 11/12/10 PB BLDG FOUNDATION STEM WALL TIME 01 00
11/12/10 AP November 12 2010 8 27 03 AM 1pangrle
BRUCE 912 0079
STEMWALL
AFTERNOON
November 12 2010 4 53 01 PM pbarthol
BLFD 01 11/22/10 PB BLDG FOUNDATION DRAINAGE
11/23/10 CA November 19 2010 4 29 18 PM 1pangrle
BRUCE 912 0079
FOUNDATION DRAINAGE
PLEASE INSPECT AS EARLY AS POSSIBLE
unable to inspect because of snow reschedule inspection
DSD 01 11/22/10 PB BLDG DOWN SPOUT DRAINS
11/23/10 CA November 19 2010 4 28 04 PM 1pangrle
BRUCE 912 0079
DOWNSPOUT DRAINS
PLEASE INSPECT AS EARLY AS POSSIBLE
unable to inspect because of snow reschedule inspection
BLFD 02 11/30/10 JLL BLDG FOUNDATION DRAINAGE
11/30/10 DA November 30 2010 8 24 53 AM 1pangrle
STAN 461 1834
FOUNDATION DRAINAGE
November 30 2010 4 38 07 PM jlierly
Items not installed yet cont has not been to this location
yet /j11
DSD 02 11/30/10 JLL BLDG DOWN SPOUT DRAINS
11/30/10 DA November 30 2010 8 24 17 AM 1pangrle
STAN 461 1834
DOWNSPOUT DRAINS
November 30 2010 4 38 07 PM jlierly
Items not installed yet cont has not been to this location
yet /j11
BL3 01 12/02/10 JLL BLDG FRAMING
December 1 2010 3 57 14 PM 1pangrle
BRUCE 912 0079
SUBFLOOR FRAMING
DSD 03 12/02/10 JLL BLDG DOWN SPOUT DRAINS
December 1 2010 3 56 35 PM 1pangrle
CONTINUED ONTO NEXT PAGE
DEC -2 -2010 01 24P FROM OLYMPIC WIRING
City of Port Angeles Permit Application
Building DlvislonlElectrlcal Inspections
321 East Fifth Street P.O. Box 1150
Port Angeles Washington, 98362
Ph: (360) 4174735 Fax; (360) 4174711
Date: 2 /C
1 2 Single Family Dwelling
Multi Family or Commercial'
Commercial Addition I Alteration 1 Remodel l Repair'
Plan Review Nlay Be Required, Please Complete Electrical Plan Review Information Sheet
Job Address: tom" it) I, 33 V1LLAVE C. 1IecLE Port Anoat.leS
Building Square 1(• I '5
Description of above S vv., r# a a d.e ee_
Owner Information
Name: Hvu51n ct
Mailing Address: Poet
City: Avte'e-teS
Phone:30 425 7L31
License 1 Exp
Unit Charge
119.90
145.50
204.60
262.20
372.50
2.60
73.50
2.60
92.70
110.30
$148.70
5 167.90
95.90
88.20
95.90
63.90
63.90
$119.90
102.30
110.30
35.20
73.50
s 110.30
58.00
At-tiko robe o4 Claijgm Co
S Fie ua is Rd
State: wA Zip; Q 8 34. 2
Fax:
1
t -tdl -"r15
1'/5 60
(360)692 -3680
t
2
Er
I SPECTIO
Total (Qtv Multiplied ()WI) Chart
4.13 Service/Feeder 200 Amp.
Service/Feeder 201 -400 Amp.
Service/Feeder 401 -600 Amp.
ServIce/Feeder 601 -1000 Amp.
Service/Feeder over 1000 Amp.
Branch Circuit W/ Service Feeder
Branch Circuit W/O Service Feeder
Each Additional Branch Circuit
Temp. Service/ Feeder 200 Amp.
Temp. Service/Feeder 201400 Amp.
Temp. Service/Feeder 401-600 Amp.
Temp. Service/Feeder 601 -1000 Amp.
Portal to Portal Hourly
Sign/Outline Lighting
Signal Circuit/ Limited Energy Commercial. Additional 1500 $5.00
Signal Clrcult/ Limited Energy 16 2 Family Dwelling
Signal Circuit/ Limited Energy Multi-Family Dwelling
Manufactured Home Connection
Renewable Electrical Energy 5KVA System or Less
First 1300 Square FL
Each Additional 500 Square Ft. or Portion of
Each Outbuilding or Detached Garage
Each Swimming Pool or Hot Tub
Thermostat
Total
TO 13604174711
Contractor Information
Name: nrVv- rt( WItt1(JP 3t4C.
Mailing Address: 91.ot Provost ti IL/
Cily St lverdo t Stale: kik Zip: 9 R' 3 f3
Phone:30 1.92.•O13 c.92 3` yo
License Exp. o sv P WI WO RV
12-2- 10
NOTE Rem Co 1 r
5E A /icE ENT P -Ah1ce k
V* 1
Signature of owner, electrical contractor or electrical administrator Cash
P 4
Owner as defined by RCW.19.28.261: (1) Owner will occupy the structure for Iwo years after this electrical permit is finalized (2) Owner Is required to hire an electrical contractor If
above said property Is for sate, rent or lease. Permit expires alter air months of last Inspection.
After reading the above statement, I hereby certify that I am the owner of the above named property ors licensed electrical contractor. I am making the electrical installation or
alteration In compliance with the electrical laws, N.E.C. RCW. Chapter 19.28, WAC. Chapter 296.480, The City of Port Angeles Municipal Code, and Utility Spoclncatlons.
Check r
Date: /2-2.-/O OK Credit Card l o11 t 1.e.,
t flues hohS eI eala._ Cu-a-,
QAVEor .Tbtrdl 3(-o 114
PREPARED 11/30/10 8 29 31 INSPECTION TICKET PAGE 2
CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 11/30/10
ADDRESS 1933 VILLAGE CIR SUBDIV
TENANT NBR RANDA L MAXHIMER
CONTRACTOR PHONE
OWNER RANDA L MAXHIMER PHONE
PARCEL 06 30 13 5 7 0110 0000
APPL NUMBER 10 00000508 RES NEW SFR
PERMIT BPR 00 BUILDING PERMIT RESIDENTIAL
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
BL1 01 11 /10 /10 JLL BLDG FOUNDATION FOOTING TIME 09 00
11 /10 /10 AP November 9 2010 3 59 04 PM 1pangrle
BRUCE 912 0079
FOOTINGS
HE REQUESTED THE EARLIEST POSSIBLE MORNING INSPECTION SO
THEY CAN POUR TODAY
November 10 2010 4 36 53 PM jlierly
BL2 01 11/12/10 PB BLDG FOUNDATION STEM WALL TIME 01 00
11/12/10 AP November 12 2010 8 27 03 AM 1pangrle
BRUCE 912 0079
STEMWALL
AFTERNOON
November 12 2010 4 53 01 PM pbarthol
BLFD 01 11/22/10 PB BLDG FOUNDATION DRAINAGE
11/23/10 CA November 19 2010 4 29 18 PM 1pangrle
BRUCE 912 0079
FOUNDATION DRAINAGE
PLEASE INSPECT AS EARLY AS POSSIBLE
unable to inspect because of snow reschedule inspection
DSD 01 11/22/10 PB BLDG DOWN SPOUT DRAINS
11/23/10 CA November 19 2010 4 28 04 PM 1pangrle
BRUCE 912 0079
DOWNSPOUT DRAINS
PLEASE INSPECT AS EARLY AS POSSIBLE
unable to inspect because of snow reschedule inspection
BLFD 02 11/30/10 JL BLDG bOrNDATION 0RAINAGE
November 30 2010 8 24 53 AM 1pangrle
STAN 461 1834
FOUNDATION DRAINAGE
T :::C1"/
DSD 02 11/30/10 JLL BLDG DOWN SPOUT DRAINS
November 30 2010 8 24 17 AM 1pangrle
STAN 461 1834
DOWNSPOUT DRAINS
COMMENTS AND NOTES
7 (ob
o raila e-cfl-vy (rt
PREPARED 11/22/10 8 26 38 INSPECTION TICKET
CITY OF PORT ANGELES
ADDRESS 1933 VILLAGE CIR
TENANT NBR RANDA L MAXHIMER
CONTRACTOR
OWNER RANDA L MAXHIMER
PARCEL 06 30 13 5 7 0110 0000
APPL NUMBER 10 00000508 RES NEW SFR
PERMIT BPR 00 BUILDING PERMIT RESIDENTIAL
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
BL1 01 11/10/10 JLL BLDG FOUNDATION FOOTING TIME 09 00
11/10/10 AP November 9 2010 3 59 04 PM 1pangrle
BRUCE 912 0079
FOOTINGS
HE REQUESTED THE EARLIEST POSSIBLE MORNING INSPECTION SO
THEY CAN POUR TODAY
November 10 2010 4 36 53 PM jlierly
BL2 01 11/12/10 PB BLDG FOUNDATION STEM WALL TIME 01 00
11/12/10 AP November 12 2010 8 27 03 AM 1pangrle
BRUCE 912 0079
STEMWALL
AFTERNOON
November 12 2010 4 53 01 PM pbarthol
BLED 01 11/22/10 JLL BLDG FOUNDATION DRAINAGE
i 1 November 19 2010 4 29 18 PM 1pangrle
BRUCE 912 0079
r 6■41. FOUNDATION DRAINAGE
PLEASE INSPECT AS EARLY AS POSSIBLE
DSD 01 11/22/10 JLL BLDG DOWN SPOUT DRAINS
November 19 2010 4 28 04 PM 1pangrle
BRUCE 912 0079
DOWNSPOUT DRAINS
PLEASE INSPECT AS EARLY AS POSSIBLE
INSPECTOR JAMES LIERLY
SUBDIV
PHONE
PHONE
COMMENTS AND NOTES
■PCii t,'r- ry 1b-5 Lt °Jl- )-4
PAGE 1
DATE 11/22/10
c)o‘(\ VoS9
eiejc\l ad5
PREPARED 11/12/10 9 03 10 INSPECTION TICKET PAGE 4
CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 11/12/10
ADDRESS 1933 VILLAGE CIR SUBDIV
TENANT NBR RANDA L MAXHIMER
CONTRACTOR PHONE
OWNER RANDA L MAXHIMER PHONE
PARCEL 06 30 13 5 7 0110 0000
APPL NUMBER 10 00000508 RES NEW SFR
PERMIT BPR 00 BUILDING PERMIT RESIDENTIAL
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
BL1 01 11 /10 /10 JLL BLDG FOUNDATION FOOTING TIME 09 00
11 /10 /10 AP November 9 2010 3 59 04 PM 1pangrle
BRUCE 912 0079
FOOTINGS
HE REQUESTED THE EARLIEST POSSIBLE MORNING INSPECTION SO
THEY CAN POUR TODAY
November 10 2010 4 36 53 PM jlierly
BL2 01 11/12/10 JLL BLDG FOUNDATION STEM WALL TIME 01 00
November 12 2010 8 27 03 AM 1pangrle
BRUCE 912 0079
v STEMWALL
AFTERNOON
COMMENTS AND NOTES
PREPARED 11 /10 /10 8 08 44 INSPECTION TICKET PAGE 8
CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 11 /10 /10
ADDRESS 1933 VILLAGE CIR SUBDIV
TENANT NBR RANDA L MAXHIMER
CONTRACTOR PHONE
OWNER RANDA L MAXHIMER PHONE
PARCEL 06 30 13 5 7 0110 0000
APPL NUMBER 10 00000508 RES NEW SFR
PERMIT BPR 00 BUILDING PERMIT RESIDENTIAL
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
BL1 01 11 /10 /10 JLL BLDG FOUNDATION FOOTING TIME 09 00
November 9 2010 3 59 04 PM 1pangrle
BRUCE 912 0079
FOOTINGS
HE REQUESTED THE EARLIEST POSSIBLE MORNING INSPECTION SO
THEY CAN POUR TODAY
COMMENTS AND NOTES
Application Number
Application pin number
Property Address
ASSESSOR PARCEL NUMBER
Tenant nbr name
Application type description
Subdivision Name
Property Use
Property Zoning
Application valuation
Application desc
1 124 SF SFR 376 SF GARAGE
Owner
RANDA L MAXHIMER
582 KEMP ST
PORT ANGELES
Structure Information
Other struct info
Permit
Additional desc
Permit pin number
Permit Fee
Issue Date
Expiration Date
T' \Policies\ 1 102 15 10/08]
WA 98362
Qty Unit Charge Per
1 00 55 0000 HR PW INSPECTION
Signature of Contractor or A /orized Agent
CITY OF PORT ANGELES
PUBLIC WORKS UTILITIES
321 EAST 5TH STREET PORT ANGELES, WA 98362
10 00000508
574700
1933 VILLAGE
06 30 13 5 7
RANDA
RES NEW SFR
RESIDENTIAL HIGH DENSITY
107396
48 SF CVRD PORCH
Contractor
OWNER
CIR
0110 0000
L MAXHIMER
000 000 1 124 SF SFR 376 SF GAR
TOTAL LOT COVERAGE
CONSTRUCTION TYPE
FIRE SPRINKLERS REQUIRED
NUMBER OF STORIES
LOT SIZE
PROPOSED LOT COVERAGE
TOTAL LOT COVERAGE
NUMBER OF UNITS
PUBLIC WORKS INSPECTION
DRIVEWAY INSPECTION
166223
55 00 Plan Check Fee
10/28/10 Valuation
4/26/11
Date 10/28/10
48 CVR PORCH
28 00
VB
YES
1 00
5379 00
1548 00
1548 00
1 00
00
0
Extension
55 00
Permit PUBLIC WORKS RES WATER SERV
Additional desc 3/4 DROP IN WATER METER
Permit pin number 166207
Permit Fee 420 00 Plan Check Fee 00
Issue Date 10/28/10 Valuation 107396
Expiration Date 4/26/11
Qty Unit Charge Per Extension
1 00 420 0000 EA PW WATER METER DROP IN 420 00
Permit PUBLIC WORKS STORMWATER
Additional desc STORMWATER CONNECTION
Permit pin number 166231
Permit Fee 135 00 Plan Check Fee 00
REPORT SALES TAX
on your state excise tax form
to the City of Port Angeles
(Location Code 0502)
Separate Permits are required for electrical work, SEPA, Shoreline ESA, utilities private and public improvements This permit becomes
null and void if work or construction authorized is not commenced within 180 days if construction or work is suspended or abandoned
for a period of 180 days after the work as commenced or if required inspections have not been requested within 180 days from the last
inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of
laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not
presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construction
?//0
Date Signature of Owner (if owner is builder) Date
CALL 417-4831 FOR UTILITY INSPECTIONS PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE IT IS UNLAWFUL TO COVER,
INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED POST PERMIT IN A CONSPICUOUS LOCATION
KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE
INSPECTION TYPE DATE ACCEPTED COMMENTS
PW UTILITIES (Engineering Division)
WATERLINE METER
SEWER CONNECTION
SANITARY
STORM
SITE DRAINAGE
SITE EROSION CONTROL
PARKING
SIDEWALK
CURB GUTTER
DRIVEWAY APPROACH
BACK -FLOW DEVICE
CONSTRUCTION R.W PW/
ENGINEERING 417 -483 I
I FIRE 417 -4653
I PLANNING DEPT 417 -4750
BUILDING 417 -4815
T Policies`1102 1 [10/08]
RESIDENTIAL
PERMIT INSPECTION RECORD
YES I NO
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE
DATE YES NO
I I I
I I I
I I
COMMERCIAL
CONSTRUCTION R.W
PW ENGINEERING
FIRE DEPT
PLANNING DEPT
BUILDING
DATE ACCEPTED
1 ES I NO
I I I
Application Number 10 00000508
Application pin number 574700
Issue Date 10/28/10 Valuation
Expiration Date 4/26/11
T' \Policies11W2 15 [10 /O8]
Qty Unit Charge Per
1 00 135 0000 EA SAN SEW STM CON OTHER
Permit
Additional desc
Permit pin number
Permit Fee
Issue Date
Expiration Date
Qty Unit Charge Per
1 00 150 0000 EA SAN SEWER HOOKUP
Special Notes and Comments
Address numbers shall be plainly visible from the street
Address numbers shall be a minimum of six inches high and be
of contrasting color from the background
A full acceptance test will be required for the fire
sprinkler system
This project will require seperate permit and fire
sprinkler plans for review
All homes in new subdivisions that are outside of the Fire
Department four minute response area shall be equipped with
residential fire sprinkler systems that comply with the
International Fire Code (IFC) and National Fire Protection
Association (NFPA)
May 25 2010 10 45 15 AM sroberds
The proposal will result in a new sfr in the RHD for a total
of 28s lot coverage and 40% site coverage No land use
issues anticipated
Electrical load calculations and electrical permits are
required
All connections to City storm drain facilities require an
inspection by Public Works and Utilities Engineering prior
cover Notice will be given 48 hours in advance of
commencing work
Sanitary sewer connection inspection is required by
Public Works prior to back fill of ditch 24 hour advance
notice is required
Construct driveway to City Standards Concrete with exposed
aggregate or other non standard finishes(including colors or
dyes)are not allowed in the City road right of way Broom
finish only An inspection by Public Works Engineering is
required prior to pouring concrete
Other Fees
SANITARY SEWER HOOK UP
CITY OF PORT ANGELES
PUBLIC WORKS UTILITIES
321 EAST 5TH STREET PORT ANGELES, WA 98362
166215
150 00 Plan Check Fee 00
10/28/10 Valuation 107396
4/26/11
RES UNDERGRND SERVICE FEE
SEWER SYSTEM DELV CHARGE
STATE SURCHARGE
PW WATER SYSTEM USE FEE
Page 2
Date 10/28/10
107396
Extension
135 00
Extension
150 00
770 00
1980 00
4 50
1980 00
REPORT SALES TAX
on your state excise tax form
to the City of Port Angeles
(Location Code 0502)
Separate Permits are required for electrical work, SEPA, Shoreline ESA, utilities private and public improvements This permit becomes
null and void if work or construction authorized is not commenced within 180 days if construction or work is suspended or abandoned
for a period of 180 days after the work as commenced, or if required inspections have not been requested within 180 days from the last
inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of
laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not
presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construction
Signature of Contractor or Authorized Agent Date Signature of Owner (if owner is builder) Date
CALL 417 -4831 FOR UTILITY INSPECTIONS PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAWFUL TO COVER,
INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED POST PERMIT IN A CONSPICUOUS LOCATION
DRIVEWAY APPROACH
BACK -FLOW DEVICE
T \Policies\) 102 15 [10/081
INSPECTION TYPE
PW UTILITIES (Engineering Division)
WATERLINE METER
SEWER CONNECTION
SANITARY
STORM
SITE DRAINAGE
SITE EROSION CONTROL
PARKING
SIDEWALK
CURB GUTTER
RESIDENTIAL
CONSTRUCTION R.W PW/
ENGINEERING 417 -4831
FIRE 417 -4653
PLANNING DEPT 417 -4750
BUILDING 41 -4815
KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE
PERMIT INSPECTION RECORD
DATE ACCEPTED
YES NO
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE
DATE YES NO COMMERCIAL DATE ACCEPTED
YES I NO
I I
I 1
I I
I I
CONSTRUCTION R.W
PW ENGINEERING
I FIRE DEPT
I PLANNING DEPT
BUILDING
COMMENTS
co PORT 9I,C
'I SYJC ,M1(0
�F.
Application Number
10 00000508
Application pin number 574700
Fee summary Charged Paid Credited
Permit Fee Total
Plan Check Total
Other Fee Total
Grand Total
CITY OF PORT ANGELES
PUBLIC WORKS UTILITIES
321 EAST 5TH STREET PORT ANGELES, WA 98362
Page 3
Date 10/28/10
Due
760 00 760 00 00 00
00 00 00 00
4734 50 4734 50 00 00
5494 50 5494 50 00 00
REPORT SALES TAX
on your state excise tax form
to the City of Port Angeles
(Location Code 0502)
Separate Permits are required for electrical work, SEPA, Shoreline ESA, utilities private and public improvements This permit becomes
null and void if work or construction authorized is not commenced within 180 days if construction or work is suspended or abandoned
for a period of 180 days after the work as commenced, or if required inspections have not been requested within 180 days from the last
inspection I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of
laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not
presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construction.
Signature of Contractor or Authorized Agent Date Signature of Owner (if owner is builder) Date
T' \Policies \I 102 15 10/08]
CALL 417 -4831 FOR UTILITY INSPECTIONS PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAWFUL TO COVER,
INSULATE OR CONCEAL 9NY WORK BEFORE INSPECTED AND 9 CCEPTED POST PERMIT IN A CONSPICUOUS LOCATION
KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE
INSPECTION TYPE DATE ACCEPTED COMMENTS
PW UTILITIES (Engineering Division)
WATERLINE METER
SEWER CONNECTION
SANITARY
STORM
SITE DRAINAGE
SITE EROSION CONTROL
PARKING
SIDEWALK
CURB GUTTER
DRIVEWAY APPROACH
BACK -FLOW DEVICE
CONSTRUCTION R.W PW/ CONSTRUCTION R.W
PW ENGINEERING
ENGINEERING 417 -4831
FIRE 417 -4653
PLANNING DEPT 417 -4750
BUILDING 417 -4815
T \Policies \1102 15 [10/08]
RESIDENTIAL
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE
DATE YES NO COMMERCIAL DATE ACCEPTED
A ES I NO I
PERMIT INSPECTION RECORD
YES I NO
I I
I I I
I I
I I I
FIRE DEPT
PLANNING DEPT
BUILDING
I I
I I
I I
I I
nal
liimp
Date
Application Number
Application pin number
Property Address
ASSESSOR PARCEL NUMBER
Tenant nbr name
Application type description
Subdivision Name
Property Use
Property Zoning
Application valuation
Application desc
1 124 SF SFR 376 SF GARAGE
Owner
RANDA L MAXHIMER
582 KEMP ST
PORT ANGELES
CITY OF PORT ANGELES
DEPARTMENT OF COMMUNITY ECONOMIC DEVELOPMENT BUILDING DIVISION
321 EAST 5TH STREET PORT ANGELES, WA 98362
Structure Information
Other struct info
Permit BUILDING PERMIT RESIDENTIAL
Additional desc 1 124 SF SFR 376 SF GARAGE
Permit pin number 165696
Permit Fee 1065 05 Plan Check Fee
Issue Date 10/28/10 Valuation
Expiration Date 4/26/11
Qty Unit Charge Per
BASE FEE
8 00 5 6000 THOU BL -100 001 500K (5 60 PER K)
Permit MECHANICAL PERMIT
Additional desc
Permit pin number 165712
Permit Fee 200 80
Issue Date 10/28/10
Expiration Date 4/26/11
Qty Unit Charge Per
3 00 7 2500 EA
1 00 10 6500 EA
8 00 14 8000 EA
/o o J C2_ /vl C C6PPS
T.Forms /Building Division /Building Permit
WA 98362
10 00000508
574700
1933 VILLAGE CIR
06 30 13 5 7 0110 0000
RANDA L MAXHIMER
RES NEW SFR
RESIDENTIAL HIGH DENSITY
107396
48 SF CVRD PORCH
Contractor
OWNER
000 000 1 124 SF SFR 376 SF GAR
TOTAL 'k LOT COVERAGE
CONSTRUCTION TYPE
FIRE SPRINKLERS REQUIRED
NUMBER OF STORIES
LOT SIZE
PROPOSED LOT COVERAGE
TOTAL LOT COVERAGE
NUMBER OF UNITS
Date 10/28/10
48 CVR PORCH
28 00
VB
YES
BASE FEE
ME VENT FAN (SINGLE DUCT)
ME STOVE /FIREPLACE /MISC APP
ME HEATER(SUSP /WALL /FLOOR MTD)
1 00
5379 00
1548 00
1548 00
1 00
Print Name Signature of Contractor or Authorized Agent
692 28
107396
Extension
1020 25
44 80
Plan Check Fee 00
Valuation 0
Extension
50 00
21 75
10 65
118 40
REPORT SALES TAX
on your state excise tax form
to the City of Port Angeles
(Location Code 0502)
Noct,
Separate Permits are required for electrical work, SEPA, Shoreline ESA, utilities private and public improvements. This permit becomes
null and void if work or construction authorized is not commenced within 180 days if construction or work is suspended or abandoned
for a period of 180 days after the work has commenced or if required inspections have not been requested within 180 days from the
last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions
of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does
not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
constructio
Signature of Owner (if owner is builder)
BUILDING PERMIT INSPECTION RECORD
PLEASE PROVIDE A MINIMUM 24 -HOUR NOTICE FOR INSPECTIONS
Building Inspections 417 4815 Electrical Inspections 417 4735
Public Works Utilities 417 4831 Backflow Prevention Inspections 417 4886
IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED
POST PERMIT IN CONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE.
Inspection Type Date Accepted By
FOUNDATION:
Footings
Stemwall
Foundation Drainage Downspouts
Piers
Post Holes (Pole Bldgs.)
PLUMBING:
Under Floor Slab
Rough -In
Water Line (Meter to Bldg)
Gas Line
Back Flow Water
AIR SEAL.
Walls
Ceiling
FRAMING:
Joists Girders Under Floor
Shear Wall Hold Downs
Walls Roof Ceiling
Drywall (Interior Braced Panel Only)
T -Bar
INSULATION:
Slab
Wall Floor Ceiling
MECHANICAL.
Heat Pump Furnace FAU Ducts
Rough -In
Gas Line
Wood Stove Pellet Chimney
Commercial Hood Ducts
MANUFACTURED HOMES.
Footing Slab
Blocking Hold Downs
Skirting
PLANNING DEPT Separate Permit #s SEPA.
Parking Lighting I ESA.
Landscaping I SHORELINE.
Inspection Type
Electrical 417 -4735
Construction R.W PW Engineering 417 -4831
Fire 417 -4653
Planning 417 -4750
Building 417 -4815
T:Forms /Building Division /Building Permit
Comments
I FINAL Date Accepted by
FINAL Date Accepted by
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/ USE
Date Accepted By
CITY OF PORT ANGELES
DEPARTMENT OF COMMUNITY ECONOMIC DEVELOPMENT BUILDING DIVISION
321 EAST 5TH STREET PORT ANGELES, WA 98362
Application Number 10 00000508
Application pin number 574700
Permit PLUMBING PERMIT
Additional desc
Permit pin number 165704
Permit Fee 142 00 Plan Check Fee
Issue Date 10/28/10 Valuation
Expiration Date 4/26/11
Qty
9 00
1 00
1 00
1 00
Unit Charge Per Extension
BASE FEE 50 00
7 0000 EA PL- PLUMBING TRAP 63 00
7 0000 EA PL -WATER LINE 7 00
15 0000 EA PL -SEWER LINE 15 00
7 0000 EA PL -WATER HEATER 7 00
Special Notes and Comments
Address numbers shall be plainly visible from the street
Address numbers shall be a minimum of six inches high and be
of contrasting color from the background
A full acceptance test will be required for the fire
sprinkler system
This project will require seperate permit and fire
sprinkler plans for review
All homes in new subdivisions that are outside of the Fire
Department four minute response area shall be equipped with
residential fire sprinkler systems that comply with the
International Fire Code (IFC) and National Fire Protection
Association (NFPA)
May 25 2010 10 45 15 AM sroberds
The proposal will result in a new sfr in the RHD for a total
of 28% lot coverage and 40% site coverage No land use
issues anticipated
Electrical load calculations and electrical permits are
required
All connections to City storm drain facilities require an
inspection by Public Works and Utilities Engineering prior
cover Notice will be given 48 hours in advance of
commencing work
Sanitary sewer connection inspection is required by
Public Works prior to back fill of ditch 24 hour advance
notice is required
Construct driveway to City Standards Concrete with exposed
aggregate or other non standard finishes(including colors or
dyes)are not allowed in the City road right of way Broom
finish only An inspection by Public Works Engineering is
required prior to pouring concrete
Other Fees
Fee summary Charged
T:Forms /Building Division /Building Permit
RES UNDERGRND SERVICE FEE
SEWER SYSTEM DELV CHARGE
STATE SURCHARGE
PW WATER SYSTEM USE FEE
Paid Credited Due
Page 2
Date 10/28/10
770 00
1980 00
4 50
1980 00
00
REPORT SALES TAX
on your state excise tax form
to the City of Port Angeles
0 (Location Code 0502)
Separate Permits are required for electrical work, SEPA, Shoreline, ESA, utilities private and public improvements. This permit becomes
null and void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned
for a period of 180 days after the work has commenced or if required inspections have not been requested within 180 days from the
last inspection I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions
of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does
not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construction.
Date Print Name Signature of Contractor or Authorized Agent Signature of Owner (if owner is builder)
BUILDING PERMIT INSPECTION RECORD
PLEASE PROVIDE A MINIMUM 24 -HOUR NOTICE FOR INSPECTIONS
Building Inspections 417 4815 Electrical Inspections 417 4735
Public Works Utilities 417 4831 Backflow Prevention Inspections 417 4886
IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED
POST PERMIT IN CONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE.
Inspection Type Date Accepted By Comments
FOUNDATION:
Footings
Stemwall
Foundation Drainage Downspouts
Piers
Post Holes (Pole Bldgs.)
PLUMBING
Under Floor Slab
Rough -In
Water Line (Meter to Bldg)
Gas Line
Back Flow Water
AIR SEAL.
Walls
Ceiling
FRAMING
Joists Girders Under Floor
Shear Wall Hold Downs
Walls Roof Ceiling
Drywall (Interior Braced Panel Only)
T -Bar
INSULATION:
Slab
Wall Floor Ceiling
MECHANICAL.
Heat Pump Furnace FAU Ducts
Rough -In
Gas Line
Wood Stove Pellet Chimney
Commercial Hood Ducts
MANUFACTURED HOMES
Footing Slab
Blocking Hold Downs
Skirting
PLANNING DEPT
Parking Lighting
Landscaping
Separate Permit #s
T.Forms /Building Division /Building Permit
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/ USE
Inspection Type
Electrical 417 -4735
Construction R.W PW Engineering 417 -4831
Fire 417 -4653
Planning 417 -4750
Building 417 -4815
'FINAL Date Accepted by
FINAL Date Accepted by
SEPA.
ESA.
SHORELINE.
Date Accepted By
Permit Fee Total
Plan Check Total
Other Fee Total
Grand Total
T:Forms /Building Division /Building Permit
CITY OF PORT ANGELES
DEPARTMENT OF COMMUNITY ECONOMIC DEVELOPMENT BUILDING DIVISION
321 EAST 5TH STREET PORT ANGELES, WA 98362
Application Number
Application pin number
1407 85
692 28
4734 50
6834 63
10 00000508
574700
1407 85
692 28
4734 50
6834 63
00
00
00
00
Page 3
Date 10/28/10
00
00
00
00
REPORT SALES TAX
on your state excise tax form
to the City of Port Angeles
(Location Code 0502)
Separate Permits are required for electrical work, SEPA, Shoreline ESA, utilities private and public improvements This permit becomes
null and void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned
for a period of 180 days after the work has commenced or if required inspections have not been requested within 180 days from the
last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions
of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does
not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construction.
Date Print Name Signature of Contractor or Authorized Agent Signature of Owner (if owner is builder)
IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED
POST PERMIT IN CONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE.
Inspection Type
FOUNDATION
Footings I
Stemwall
Foundation Drainage (Downspouts') I
Piers
Post Holes (Pole Bldgs.) I
PLUMBING
Under Floor Slab I
Rough -In
Water Line (Meter to Bldg) I
Gas Line
Back Flow Water I
AIR SEAL.
Walls
Ceiling I
FRAMING
Joists Girders Under Floor
Shear Wall) Hold Downs I
Warms Roof Ceiling I
Drywall (Interior Braced Panel Only I
T -Bar I
INSULATION:
Slab I
Wall Floor Ceiling
MECHANICAL.
Heat Pump Furnace FAU Ducts
Rough -In
Gas Line
Wood Stove Pellet Chimney
Commercial Hood Ducts
MANUFACTURED HOMES
Footing Slab
Blocking Hold Downs
Skirting
PLANNING DEPT Separate Permit #s
Parking Lighting
Landscaping
Electrical
Construction R.W PW Engineering
Fire
Planning
Building
T /Building Division /Building Permit
BUILDING PERMIT INSPECTION RECORD
PLEASE PROVIDE A MINIMUM 24 -HOUR NOTICE FOR INSPECTIONS
Building Inspections 417 4815 Electrical Inspections 417 4735
Public Works Utilities 417 4831 Backflow Prevention Inspections 417 4886
Inspection Type
Date Accepted By
t 1�-I
to
FINAL
Comments
Date I
Accepted by
3 -3 -11 Frek-olinJ ?1
FINAL Dat Accepted by
SEPA.
ESA.
SHORELINE.
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/ USE
Date Accepted By
417 -4735
417 -4831
417 -4653
417 -4750
417 -4815 —21 —1 I
C: NOTE
t" OMB No. 2502 -0265
FINAL B. TYPE OF LOAN
A. SETTLEMENT STATEMENT (HUD i FHA 2. FHMA 3 CONV UNINS.
,II■ieau 4 u VA 5 CONV INS.
OLYMPIC PENINSULA 6. FILE NUMBER. 7 LOAN NUMBER
-Title company- 95722 -DS 39027.710.
TIRE INSURANCE• ESCROWS
8. MORTGAGE INS. CASE NO
This form is furnished to give you a statement of actual settlement costs. Amounts paid to and by the settlement agent are shown. Items
marked '(p.o.c.)' were paid outside the closing; they are shown here for informational purposes and are not included in the totals.
I) NAME ADDRESS
OF BORROWER.
E. NAME ADDRESS
OF SELLER.
F NAME ADDRESS
OF LENDER.
G. PROPERTY LOCATION 1933 Village Circle, Port Angeles, WA 98362
14. SETTLEMENT AGENT Olympic Peninsula Title Company
PLACE OF SETTLEMENT 319 S. Peabody, Suite A, Port Angeles, WA 98362 (360) 457 -4451
I. SETTLEMENT DATE 10/25/2010 DISBURSEMENT DATE. 10/25/2010
J. Summary of Borrower's Transaction
100. Gross Amount Due From Borrower
101 Contract sales price
102. Personal property
103 Settlement charges to borrower (line 1400)
104 HACC Prints, Eng., CC, Ins., Taxes, Permits, Cr Rpt
105 USDA Construction Holdback
Adjustments For Items Paid By Seller In Advance:
106. City/town taxes to
107 County taxes to
108. Assessments to
109
110.
111
112.
113
114
115
116.
120. Gross Amount Due From Borrower
I 200. Amounts Paid By Or In Behalf Of Borrower:
201 Deposit or earnest money
202. Principal amount of new loan(s)
203 Existing loan(s) taken subject to
204
205
206. HTF Loan Funds
207
208.
209
Adjustments For Items Unpaid By Seller
210. City/town taxes to
211 County taxes to
212. Assessments to
213
21.4
215
216.
21
218.
219
220. Total Paid By/For
Borrower.
300. Cash At Settlement From /To Borrower:
301 Gross amount due from borrower (line 120)
302. Less amount paid by /for borrower (line 220)
303. Cash ❑FROM) 1IJI'O) Borrower
Previous Edition Is Obsolete
Form No. 1581
3/86
Randa L. Maxhimer
582 Kemp St., Port Angeles, WA 98362
Housing Authority of County of Clallam
2603 S. Francis St., Port Angeles, WA 98362
USDA Rural Development
1601 E. Front St., Ste B, Port Angeles, WA 98362
58,500.00
2,648.81
10,081.19
93,165.00
164,395 00
10.00
159,385.00
5,000.00
520. Total Reductions
In Amount Due Seller
1 600. Cash At Settlement From/To Seller:
164,395.001 601 Gross amount due to seller (line 420)
164,395.001 602. Less reductions in amount due seller (line 520)
0 00 603. Cash OW) FROM) Seller
164,395 00
Page 1 of 3
K. Summary of Seller's Transaction
400. Gross Amount Due To Seller
401 Contract sales price
402. Personal property
403
404
405
Adjustments For Items Paid By Seller In Advance:
406. City/town taxes to
to
to
407 County taxes
408. Assessments
409
410
411
412.
413
414
415
416.
420. Gross Amount Due To Seller
500. Reductions In Amount Due To Seller:
501 Excess deposit (see instructions)
502. Settlement charges to seller (line 1400)
503 Existing loan(s) taken subject to
504 Payoff 1st Mtg. Ln.
505 Payoff 2nd Mtg. Ln.
506. HACC SHOP 06 -01
507 HACC Revolved Funds
508.
509
Adjustments For Items Unpaid By Seller
510. City/town taxes to
511 County taxes to
512. Assessments to
513
514
515
516.
517
518.
519
58,500.00
58,500.00
15,000.00
43,500.00
58,500.00
58,500.00
58,500.00
0 00
SB-4- 3538 -000 -1
HUD -1 (3 -86)
RESPA, HB 4305.2
City of Port Angeles
Building Division
329E 5 St.
Port Angeles, WA 98362
RESIDENTIAL 1 r1w i e-`i is aI RE-VIE-Lev' r+I II1.. GUIDELINES
RE IIJ IV IIAL 6'LA GUIDCLIIVCJ
PLAN REVIEW
Items described here are only a guide to common questions and missed items during plan review and
construction. All codes must be complied with (Please read and follow each item) SPECIAL NOTE.. Check
item #59 first to see if enaineerina will be needed because of lateral design. issues:
GENERAL.
1 Final grading of the property must be done prior to final inspection even if owner is doing required retaining
walls Occupancy of the home will not be allowed until there are no slopes steeper than 2 units horizontal
to 1 unit vertical or retaining walls are in place or an accepted soils report is submitted to the City If a
soils report was required initially all requirements of the soils report must be accomplished prior to final
inspection including submittal of all field reports
2. Acrylic stucco products have special requirements Verify such with the manufacturer Requirements may
include tongue and groove foam 'board under finish control joints special backing boards (sometimes OSB
is NOT allowed) self- furring or furred -out wire or fabric lath and sometimes installation by a certified
installer (certified by the manufacturer) Verify any and all requirements of stucco siding or acrylic stucco
products NO INSPECTION OF LATH OR STUCCO IS REQUIRED, BUT WRITTEN CERTIFICATION
BY A MANUFACTURER'S CERTIFIED INSTALLER MUST BE LEFT AT THE JOB SITE UNTIL FINAL
INSPECTION BY THE CITY
3 Inspection of shear wall nailing roof sheathing to blocking nailing and hold downs must be requested in
addition to standard inspections and before such items are covered up Please specify shear nail roof nail
or hold -down inspection when you request these they may be done simultaneously if ready
4 This plan is approved for OSB or plywood exterior wall sheathing only unless the approved plans at the
time of permit issuance reflect other materials being used Any change to wall sheathing material after
permit issuance must be submitted to the city for review prior to installation An additional plan review fee
will be assessed
"5. "Tyvek" or equal approved weather resistive barrier (15# felt is OK) required on the exterior side of all
walls regardless of the type of siding used This includes garage walls gable portion of end walls and
t cripple walls (at stepped foundation conditions) Apply over exterior sheathing or over studs in single -wall
construction T 1 11 or similar panel siding must have Tyvek' or equal over the. studs.
6 Exterior windows and doors shall be flashed with approved materials and caulking Caulked trim material
over the window or door flange is not an acceptable method
7 Overall dimensions of house plan must match site plan dimensions Verify any special requirements for
buildings located close to property lines R302
1 Building/Handouts/Residential Plan F eview Gui clines (Rev 03- 18 -09)
Page 1 of 8
LIFE SAFETY MISC ITEMS
8 Sleeping rooms must have an egres window with 5 7 s f net clear opening 24 min height 20" min
width 44 maximum from floor to window sill Windows must meet all 4 dimensions R310 1
9 Safety or tempered glass shall be used in windows that are (R308 4)
Adjacent to a door (24" arc of either edge of the door in a closed position)
That are closer than 18" to floor (AND individual .pane is more than 9 s f top edge more than 36" a.f f
and walking surface within 36" horizontally of the window in question)
Walls enclosing a tub or shower (AND within 60" of the drain or within 60" of walking. surface) R308 4
Adjacent to stairways landings and ramps within 36" horizontally of a walking surface -(AND less than
60' a.f f of the walking surface)
Adjacent to stairways within 60" of the bottom tread of the stair in any direction (AND less than 60'
aff)
10 Under -stair areas that are enclosed and accessible must be sheetrocked 1/2" GWB on walls and
underside of the stairway R311 2 2
11 Stairways shall have 10' min tread and "7 3/4 max. rise R311 5
12. Provide 36" high guards (with_ 4" max. spacing on rails) at porches balconies and raised floor surfaces
more than 30" above adjacent ground or floor R312 1
13 Smoke detectors required at all bedrooms hallway or room adjacent to bedrooms and at any ceilings that
are more than 24" above adjacent ceiling All smoke detectors interconnected and hardwired with battery
back -up R313 1
14 Garage /house separation wall is 1/2" GWB door must be 20 min rated or 1 3/8" solid -core If living space
above use 5/8 GWB Type 'X" at the ceiling AND 1/2" GWB at walls that support the floor above Ducts in
garage must be 26 -gage sheet steel and have no openings in the garage R309
15. Exterior stairways must have a light located near the top landing of the stairway switched from inside (or
have motion activation device) R303 6
16 Minimum room areas must be provided (120 s f min in at least one room 70 s f min all other habitable
rooms 7 foot min dimension in all habitable rooms) R304 1
17 Minimum ceiling heights must be provided (7 foot min with some exceptions) R305 1
FOOTINGS, FOUNDATIONS, AND CRAWL SPACES
18 All footings including exterior isolated pad footings must have a 24" (min) depth from the bottom of the
footing to finished grade R403 1 4 1
19 All footings shall be supported on undisturbed natural soils or engineered fill Any placement of fill material
that will support a structure will require a geotechnical investigation and report submitted to the City prior to
,placement of footings R401 2 R403 1
20 Lots shall be graded to drain surface water away from foundations The grade shall fall 6' in the first TEN
feet around the perimeter of the structure R401 3
21 Top surface of footings shall be level Bottom surface of footings shall not have a slope that exceeds (1)
unit vertical in (10) units horizontal Any _necessary stepping of the foundation must be approved during
plan review or prior to installation of the foundation R403 1 5
T Building /Handouts /Residenl,al Plan Review Guidelines (Rev 03- 18 -09)
Page 2 of 8
22. Wood sill plates of all exterior walls interior bearing walls (slab -on- grade) and interior shear walls (slab -on-
grade) must be anchored to foundation or slab with X 10' J -bolts with a 2' X 2" X 3/16' plate washer
Anchor bolts to be placed a maximum of 12' and no closer than 3 1 /2" from the ends of the sill plate Each
piece of sill plate must have a minimum of (2) anchor bolts Anchor bolts shall be spaced no further than 6
feet apart. (Special spacing and sizing conditions may apply at alternate braced wall panels) R403 1 6
23. 6' clearance required from finish grade to foundation mudsill plate R319
24 3 1/2' (min thickness for all concrete slabs -on -grade R506 1
25 Footing and foundation wall SIZES for two pour system
(Foundation walls NOT over 5 feet in height)
Footing supporting single story- 12' wide X 6' thick.
Foundation wall supporting single story 6" thick
Footing supporting two stories- 15' wide X 7" thick.
Foundation wall supporting two stories- 8" thick.
Foundations that support more than two stories require an engineered design
.26 Footing and fnd REINFORCEMENT for two pour system fnd. walls NOT over 5 feet in height)
(Footings supporting single or two stories)
One continuous #4 horizontal rebar placed at center of footing with 3 (min) clearance from dirt.
(Foundation walls not over 5 feet in height)
One continuous #4 horizontal rebar placed within the top 12" of the wall
#4 vertical rebar placed at 48 inches o c max (wet set ok) with a 6 -inch 90- degree hook. A
minimum of (2) vertical bars to be placed at front garage wall returns
27 Monolithically poured foundation systems
Bottom of footing shall be 12" wide (min and extend to 24 below finished grade minimum
Footing shall have either one #5 continuous horizontal rebar placed at center and 8' above bottom of
footing or (2) #4 continuous horizontal rebar placed at center and in the middle third of the footing
measuring vertically
3 1/2" minimum slab thickness
When a monolithib system is used to support heated spaces an R 10 insulation board must be
installed on the outside of the foundation extending from bottom of footing to top of slab Exposed foam
insulation above grade must be protected from damage and sun with approved materials The material
used must extend a minimum of 12' below grade
28 Basement Walls (up to 9 feet) or Stem Walls (over 5 feet) or STEPPED FOUNDATIONS There are
special restrictions for this type of foundation wall under the new code In. plan view the length of this type
of wall cannot exceed 35 feet. For stepped foundations this wall cannot exceed 7 feet high otherwise the
floor joists must connect DIRECTLY to the wall (for bracing the foundation wall) WET SETTING IS NOT
allowed for the alternating hooks into the footing There are special blocking requirements if any of these
conditions cannot be met (note on the plans!) See R404 1
29 Under -floor pier pads supporting uniform load of wood framed floors shall be 18 "x 18' x 8" (min) Point
loads from other than floor girders will require larger footings sized according to the concentrated load
R403 1 1
30 Beams and /or girders in crawl space must meet span requirements for the loads imposed (from floor joists
and from any point loads) R501 2
T Building /Handouts /Residential Pion Reviev Guidelines (Rev 03- 18 -09)
Page 3 of 8
31 Access shall be provided to all under -floor spaces Access openings through the floor shall be a minimum
of 18' x 24 Openings through a perimeter wall shall be a minimum of 16" x 24" R408 3
32. Under -floor spaces shall be ventilated by openings providing one (1) square foot of vent area per 150
square feet of crawl space area One such ventilating opening shall be within 3 feet of each corner of the
building R408 2
33 A ground cover of 6 mil black polyethylene or approved equal shall be laid over the ground within crawl
spaces The ground cover shall be overlapped 12' and extend to the foundation wall WSEC 502 1 6 7
34 The under -floor grade shall be cleaned of all vegetation and organic material All wood forms and,
construction debris shall be removed prior to final- inspection R408
35. Thickened -slab footings must be 12" min total depth (top of conc. slab to bottom of footing, 12" total)
(Revised from. IRC)
36 Foundation cripple walls shall be framed of studs not less in size than the studding above Cripple walls
with a height less than 14 inches shall be sheathed on one side with a wood structural sheathing or shall
be of solid blocking Cripple, walls count as .an additional story" for lateral purposes R602 9
FLOOR FRAMING
37 18' (min) clearance beneath all floor joists and 12" (min) clearance beneath floor girders (beams) in crawl
spaces R308
38 Span of all joists (including 2 level joists) must meet minimum live load of 40 psf (general living areas) or
30 psf (sleeping rooms) together with dead load of materials used R301 5 and Table R301 .5
39 Span of beams for 2nd level or other supporting elements must meet minimum live and dead load
requirements R301 5
40 Wood posts in the crawl space shall have a connection to the concrete pier and a moisture barrier between
the post and footing (or use pressure treated posts) R319 R407
41 Solid -sawn floor joists shall be blocked at all bearing points Engineered floor joists shall be installed per
manufacturer's specifications R502.7
42. Cutting drilling and notching of floor joists shall not exceed the limitations in Figure R502 8
43 Cutting drilling and notching of engineered I- joists shall be in accordance with the manufacturer's
specifications R502.8 2
44 All concentrated point loads originating from roof or floor load shall be transferred to bearing footings or
foundation walls Continuous support shall be provided by members that are equal in cross sectional area
to the area of the load imposed and shall not be reduced in size at any point.
45 Wood members supported in concrete or masonry pockets shall have a Y2 inch air space provided at tops
sides and ends of the member
46 All foundation plates sills and sleepers bearing on a concrete foundation or slab that is in direct contact
with the ground shall be pressure treated All wood framing members that rest on concrete foundations
and are within 8" of exposed ground shall be pressure treated R319
T Building /Handouts /Residential Plan Review Guidonnes (Rev 03-18-09)
Page 4of8
47 Sawn lumber floor joists shall have 1% (min) bearing and shall lap 3 min at intermediate girders
Engineered I- joists shall have 1 3/4 (min) bearing (or per manufacturer's specifications)
48. Floor joists that are parallel to bearing partitions shall be doubled Some heavier load cases will require
girder beams or pony walls Bearing partitions perpendicular to floor joists shall not be offset from the
supporting girder more than the depth of the joists unless the floor joists are of sufficient size to carry the
load R502.4
49 Floor cantilever spans shall not exceed the depth of the nominal floor joists Floor cantilevers constructed
in accordance with Table R502 3 3 (1.) shall be permitted when supporting a light framed bearing wall and
roof only R502 3 3
50, Block in between floor joists beneath all interior braced walls (for walls perpendicular to joists) or align floor
joist with interior braced wall (see item #63 -T)
WALL FRAMING
51 Wall studs taller than 10 feet shall have a stud height analysis by a professional engineer or architect.
Table R602.3 -5
52. Non -load bearing stud heights shall be in accordance with Table R602.3 (5)
53 Studs shall be a minimum #3 grade standard grade or stud grade lumber R602.2
54 Where joists trusses or rafters- are spaced more than 16" o c and the bearing studs below are spaced at
24" o c such members shall bear within 5' of the studs below unless the top .plates are double 2x6 or a
third plate is added R602.3 3
55 Headers over windows and doors must meet minimum requirements for spans and imposed loads verify
point loads over openings (from trusses or other conditions) and size headers accordingly Headers must
be noted with size type and grade of lumber being used
GENERAL NOTE STATING ALL HEADERS SHALL BE is acceptable
56 Interior bearing walls must have headers over openings and must be supported to a foundation
57 Top plate splices shall be offset a minimum of 24 inches R602 3 2
58 Fire blocking required at dropped ceilings soffits coved ceiling areas and every ten feet horizontally and
vertically at framed walls R602 8
59 Port Angeles is in Seismic Zone D1 Wind zone of 100 MPH Category C (within 1500 ft from shore line is
Category D) per the 2006 IRC When a house is considered IRREGULAR by any ONE the definitions
below the code will NOT allow prescriptive bracing for Seismic Zone C and the entire house must have a
lateral analysis and design by a licensed engineer (R301 2 2 2 2) Per that section of the code NO MIXING
OF PRESCRIPTIVE AND ENGINEERED LATERAL SYSTEMS IS ALLOWED UNDER THIS NEW 2006
IRC
The following are items that constitute an IRREGULAR BUILDING per the 2006 IRC
A. Exterior braced wall lines must be in one plane vertically from foundation to the uppermost story
(basically the upper floor must match the lower floor footprint) The most common area where
problems like this occur is in a garage with a second floor over it. To qualify for prescriptive bracing
the second floor joists must extend to the exterior walls of the garage If this does NOT occur then
your proposed house is IRREGULAR If the joists do extend to the exterior walls of the garage then
the setback of the second floor walls cannot he more than four (4) feet setback from the garage walls
T i3ad,ng /Handouts /Residential Flan Review Guidelines (Rev 03- 18 -09)
Page 5 of 8
(see p 44 of the 2006 IRC) Rooms created by roof trusses are OK under this provision (such as
bonus rooms over garages formed by the trusses /rafters)
B The perimeter of all floor diaphragms and all roof diaphragms must be supported on WALLS below If
you have beams holding up any part of the perimeter of a floor or a roof then your proposed house is
IRREGULAR. The most common place you will find this problem is at large covered porches and
patios where the roof is supported only by post and beams Such covered porches and patios also
make the building IRREGULAR Related to this are areas of discontinuous diaphragms especially
changes in plate line heights which also are considered as separate 'roofs and therefore make the
building IRREGULAR
C In any elevation of the exterior the. braced walls from an upper level wall must NOT occur over a
window or door In general this means that the windows of the upper story must align with the
windows of the lower story There are some exceptions based on up- sizing the header in the window
below (see 2006 IRC p 44 for details)
D When an opening in a floor .or roof (such as a balcony overlook area or a courtyard area) exceeds the
lesser of 12 feet or 50% of the least dimension then your proposed house is IRREGULAR.
E. When portions of a floor level are vertically offset (such as -a sunken room) then your proposed house
is IRREGULAR This does not apply to a slab-on-grade floor
F When braced wall lines do not occur in two perpendicular directions (such as portions of the house or
garage at an angle to the rest of the building) then your proposed house is IRREGULAR.
G If you have any portion of the above -grade walls that use masonry or concrete construction then your
proposed house- is IRREGULAR. Stepped foundations that create a daylight basement situation are
OK under this provision and do not make an irregular structure
60 THIS APPLIES TO ALL LATERAL BRACING (ITEMS 61 THRU 65) Add up all lengths of braced panels
(4 foot braced panels 2 -8' alt. braced panels and 24 or 16' portal frames COUNT as 48' of length .each
portal frame counts as a total of 48' of bracing length —not 2 times 48 along the wall in question The
total length of braced walls must be at least 16% of the entire wall length AND the panels must occur at
least every 25 feet along the wall For 15t story of 2 -story house 30% of the entire wall length must be
braced walls Check this for all braced wall lines including INTERIOR WALLS and including the front wall
of a garage if it is not part of another braced wall line (i e the garage sticks out in front of the house more
than 4 feet) See also #65 T below for areas where MORE than 35 feet between wall lines is needed
61 Garage lateral bracing systems with no 2 floor above
H Portal Frame for Garages (16" side panels. 8 foot max. high walls 20' side panels 10 foot max.
high walls)
I Alternate Braced Walls— single -story condition (2' -8" min width X 10 foot max. height) sheathed on
one side (interior or exterior OK) with min 3/8" OSB or plywood and nailed with 8d common or galv
box nails and blocked at all edges Two (2) anchor bolts in sill plate two (2) hold -down devices
furthest studs (1800 pound capacity hold downs)
J Alternate Braced Walls —first floor of two -story condition (2' -8' min width X 10 foot max. height)
sheathed on BOTH interior and exterior sides of wall with min 3/8 OSB or plywood and nailed with 8d
common or galv box nails and blocked at all edges Two (2) anchor bolts in sill plate two (2) hold
down devices furthest studs (3000 pound capacity hold downs) There are some provisions for plate
lines up to 12 feet high see Table R602 10 6 (basically a wider wall 3 -6' min length for 12 feet high)
K. Front Garage Panels —no hold -downs required
L. The exterior braced wall lines in a detached or attached garage cannot be more than 35 feet apart in
either direction or interior braced walls must be. provided
62. 1 Floor Conditions Four (4) foot solid walls at all corners and at every 25 feet along any braced wall
line OR use one of the methods below
M Portal Frame for a House (slab -on -grade floors ONLY) 16 min width for one -story structures 24 min
width for first floor of 2 story
T Building /Ha,,douts /Res dential Plan Review Guidelines (Rev 03- 18 -09)
Page 6 of 8
N Alternate Braced Walls single -story condition (2' -8" min width X 10 foot max. height) sheathed on
one side (interior or exterior OK) with min 3/8 OSB or plywood and nailed with 8d common or gals
box nails and blocked at all edges Two (2) anchor bolts in sill plate two (2) hold -down devices
furthest studs (1800 pound capacity hold- downs)
O Alternate Braced Walls —first floor of two -story condition (2' -8" min width X 10 foot max height)
sheathed on BOTH interior and exterior sides of wall with min 3/8" OSB or. plywood and nailed with 8d
common or galv box nails and blocked at all edges Two (2) anchor bolts in sill plate two (2) hold
down devices furthest studs (3000 pound capacity hold downs) There are some provisions for plate
lines up to 12 feet high see Table R602 10 6 (basically a wider wall 3 -6' min length for 12 feet high)
P "Simpson Brand StrongWalls —this method is still available following all the manufacturer's
specifications for
Q. Entire House Sheathed with OSB or Plywood —this method allows smaller side panels than 4 feet in
accordance with Table R602 10 5 CHECK THE OPENING HEIGHTS ADJACENT TO THESE
PANELS!
63 .1st Floor Conditions Braced wall (any of the methods listed above) must start at..no more than 12.5 feet
away from the corner of the braced wall lines and then at every 25 feet (min along the wall line
64 2 Floor Conditions Braced walls (either of the methods listed below) must be within. 12:5 feet of the
corner of the wall line in question
R. Standard four (4) foot panels on 2 levels can start at no more than 12.5 feet away from the corner
S Entire House Sheathed with OSB or Plywood —this method allows smaller side panels than 4 feet in
accordance with Table R602 10 5 CHECK THE OPENING HEIGHTS ADJACENT TO THESE
PANELS!
65. Exterior braced wall lines (or together with some interior wall lines) cannot be more than 35 feet apart.
T Certain areas can be up to 50 feet apart between wall lines IF there is additional bracing along the
exterior wall in question (50/35 1 43 more bracing than normally required or in other words 23% of
the total wall in bracing for 1 -story wall 43% of the total wall in bracing for 1 story of a 2 -story house)
R602 10 1 1 Exception 1 and 2
U Interior Braced Walls can be used when exterior walls are more than 25 feet apart. Interior Braced
Walls are minimum 1/2' GWB both sides of wall for a minimum length of 48" use 5d nails or screws at
7' o c Sole plate of wall must be attached to thickened slab footing (see item #22 above) with 1/2"
anchor bolt 6' -0' o c. or solid blocking (walls perpendicular to joists) or LINE UP JOIST with braced
wall (walls parallel to joists)
66 The roof sheathing MUST nail into SOLID blocking and the block must connect to the double top plate
either with clips or toe nailed (for blocks that are top beveled) with 8d 6' o c For ventilation use not
more than two (2) 2' diameter holes BLOCKING MUST OCCUR AROUND ENTIRE PERIMETER OF
ALL ROOFS Table R602 3 (1) This applies to all houses both engineered AND prescriptive bracing
ROOF ATTIC
67 Truss drawings must show reactions of all girder trusses point loads onto headers must have headers
sized accordingly point loads over 5000 lbs onto double -top plates must be checked for .bearing capacity
Use Simpson brand TBE4 or TBE6 as needed to spread the load
68 Truss bottom chord live load must be minimum of 10PSF (see Table R301 5) Trusses must be sized for
the roof coverings specified on the plans (concrete tile etc) and roof structure must be able to hold up the
roof (beams headers etc sized for roof loads) R802 10 2
69 Ice Shield is required for roofs up to 6 12 12 and over DO NOT require ice shield) R905 2 7 1
T Building /Handouts /Residential Ran Reviev c'_tidelines (Rev 03- 18 -09)
Page 7 of 8
70 Attic ventilation must be provided at 1/150 of the attic area or 1/300 of the attic area if 50% of the venting
can be 3 feet above the eave venting (roof jack vents are 49 sq in. /vent ridge vents at 12 sq in. /foot)
R806 1
71 Attic mechanical equipment, need light and switch near opening and electric outlet. Access opening to
such mechanical equipment must be no further than 20 feet from equipment with 22" wide (min) walkway
from access opening to the equipment,
72. Attic access required 22" X 30' min and shall be in hallway or other readily accessible location R807 1
MECHANICAL.
73 Appliances located in a garage or carport shall be protected from damage from vehicles M1307 3 1
74 Gas appliances located in a garage shall be raised 18" min above finish floor G2408 2 (305 3)
75 Ductwork that extends below grade (such as in the garage floor) ,shall be encased in 2" min concrete on all
sides and bottom in addition to the R 10 insulation foam board 603 8 IMC
76 Dryer exhaust ducts shall not exceed 25 feet in length The maximum length of the duct shall be reduced
2.5 feet for each 45- degree bend and 5 feet for each 90- degree bend Longer lengths in accordance with
the manufacturer's listing will be allowed Screws shall not be used to connect any dryer duct materials
M1501 3
77 Flex duct connections to sheet metal transition ducts shall have the inner sleeve taped with approved
materials prior to securing the flex duct with a zip tie or similar fastener 304 IMC
78 Flex duct shall be supported every 4 feet and have no sag that exceeds 1 /2 per foot.
79 All exhaust fan ducts shall be connected to the fan housing and termination fittings with a minimum of 3
sheet metal screws and be sealed.with approved tape or mastic.
80 Exhaust fans required 50 cfm in bathrooms 1.00 cfm in kitchen 50 cfm min in laundry room and one fan
sized for whole -house ventilation 302 2.2 WSVIAQ
81 Fuel burning equipment shall not be installed in a closet, bathroom or a room readily usable as a bedroom
82. Water heaters must be .secured to structure with straps around tank at 1/3 points to resist lateral
displacement. M1307 2
PLUMBING
83 Cleanouts shall be installed on all sinks and at the upper end of all building drains including any horizontal
drain branches greater than 5 feet in length from the main line A cleanout shall also be installed on the
exterior of the house within 24 inches of the foundation wall level with final grade and shall have a
threaded :type bap installed
84 30" min width for toilet and 24" clear space in front of toilet (UPC)
85 Water heaters pressure relief and the required' drain pan shall have a drain that is ID copper or cpvc
material NO coil material shall be allowed per code and no reduction in the pipe shall reduce the ID of the
material less than Pex type is a coil material and is not allowed for this application
T Building /Han Jouts /Re ,idential Plan Review Guidelines (Rev 83- 18 -09)
Page 8 of 8
W nek_ship eer'-Coun`y i s Zk 5 1 20 110 \ovstn3 off Clallarn 2_403 s Fromds S-F
BUILDING PERMIT APPLICATION P in i es,WA
rcur
\er 9836
Applicant (1
4- Property Owner R L, Pa 0,..XVA t l Phon
Property Owner's Addre s 5 Ke 54- W P- 6)
Contractor o v,)6.�c Lt.,.,1 der
Phone
Contractor's Address r
License Expires
PROJECT ADDRESS
Parcel Number
Project Type Brief Description.
Check all that apply
)gillew Construction
Addition
Remodel
Repair
Demolition
Re -roof
-feat System
Other
Floor Areas
Basement
1 Floor
2 Floor
3 Floor
Garage
Carport
Covered Porch
Deck
Shed
Other
Max. height of proposed structures
Will a lawn sprinkler system be installed?
Will a fire sprinkler system be installed?
T Forms /Building Division /Building permit applicajon
CITY OF PORT ANGELES
Attn Building Permit Technician
321 E Fifth St. Port Angeles WA 98362
(360) 417 -4815 fax (360) 417 -4711
o (Q3OI`3''57o t1 0
VL e-w
Existing (sq. ft.)
I (.i?
glResidential Multi- family
S ,ti.4 l 1 S
I
Rouse garage other
Heat pump wood- burning stove gas fireplace pellet stove other
le.c -i.c.. i i)0-11 \l\ QJ zr
Proposed (sq. ft.)
ft.
h ay
3 Co
4 8
Occupancy group
Occupant load
Construction type
30
E -mail
For City Use Only `J
Date Received 5-1R-10 l
Permit# 1c -Sp$
ate Approved
at. a1Z7 l z4'>
12 001cc
Lot I I Zoning
of bedrooms
of full baths
of half baths
have read and completed this application and know it to be true and correct. I am authorized to apply for this permit
that it is my responsibility to determine what permits are required, and to obtain permits pri o wo g on projects
Date C IC Print Name E C Signature
oC Industrial
W' Q_ C- q °L a q wQ_
V
tear off re -roof lay over one layer
per sq ft.
c1",.>"
I l z 8 0
C i l Ve- Cot Q V TOTAL VALUATION 1 01 3 1.
Total footprint of structures t 5 sq ft. T Lot size sq ft. Lot coverage 20
Site Coverage the amount of impervious surface on a parcel including structures paved driveways sidewalks,, patios
and other impervious surfaces (see PAMC 17 94 135 for exemptions) Site coverage "I 0
i0
oil 0
r
1-
i
1
1 1
0
0
0
\Q 3
CITY GOVERNMENT Site Information.
Lot:
Address
City
State
Contact.
Phone
Phone 2
FAX
Ut \\ck-q Je-
U)ce Zip ct 36,7—
P 1 'e Sc �-'Q-
91? 1' 12 oo'1
Table 6 -1
PRESCRIPTIVE REQUIREMENTS FOR GROUP R OCCUPANCY
CLIMATE ZONE 1
(Unlimited Glazing Option Only)
Glazing' Glazing "U- Factor :Door Wall: Wall WaIF
Vaulted "Interior Exterior
Option Ar Flooc of Vertical Overhead. Factor Ceiling. Ceiling `Grade. Below .Below .Floor
Vertical Grade'
Unlimited
Group R 3
IV and R -4 0 35 0 58 0.20 R 38 R 30 R 21 R 21 R 10 R 30 R 10
Occupancies
Only
This Project complies with the following.
T Forms /Building Division /Prescriptive Approach Simple Form
PRESCRIPTIVE APPROACH- SIMPLE FORM
For the Washington State Energy Code (2006 Edition)
Climate Zone 1
Building Department Use Only-
Permit 0 —50R
Notes
Ai The project is a single- family residence or duplex.
AI The project is a wood frame OR all of the insulation is interior or exterior of the framing.
'i All building components meet the requirements listed above.
A/ The project will meet all other provisions of the WSEC and VIAQ
The Project will take advantage of the following exceptions to the prescriptive option.
'602.6 Exception 2. One unlabeled or untested exterior swinging door 24 sq ft. or less, may be
Installed per unit for ornamental, security or architectur 'purposes.
Location of the door taking this exception 61 a o
602.6 Exception 2. If a door is mostly glass, it should meet the requirement of the vertical
glazing U factor listed above
Location of the door(s) taking exception.
Type of Heat Source L° �c��C� 1.0.3 .1(
Slab on
Concrete
II k
NORIP
1RA4 6
Please complete and return to Public Works Utilities Department
Applicant Information
Permanent service.
Name and address of party
responsible for permanent
service billing?
Contact Information
Site contact:
Contractor
Electrician.
Excavator
Ingle- family residence
Commercial
Overhead service
Underground service
Projectanformation
Street address lot number
Nearest cross street:
Desired connection date
Electrical' Loa
Electrical transformer serving property is
Total square footage
Voltage
Check all that apply
No Load Change
Supporting Documentation
Please provide a copy of the following
*Detailed plot plan (dwg or dxf format mandatory for subdivisions)
"Electrical one -line drawing showing the service entrance panel and location
"Size and locked *Connected load data.
rotor f all motors over
Applicant's Signature
MAIL OR DELIVER COMP
FAX TO 360 -417 -4711
Information form.xls
Name.
Street:
Ni Vt� k HIV .1 !Cl iyin;ilsUr for m:tticrri is
1 c r 0 olt0.Q
City State ZIP cl&`3 Le Z—
Daytime Phone
(if other than above)
Name H
Daytime Phone
1Name N CC- Company
I Daytirrie Phone
Name
Daytime Phone
Name
Daytime Phone
Existing
Description of work:
1 1 2 9__sq ft.
620/240 1 ph
0120/240 3ph
Electrical Information Form
�o4 r_t` L i? 1 4 ri
15rti c.1L Title C.c. cv5+ 3 v pt
11Z. oo 7 9
L 5z'1431
Company
Company
Home Phone
251-ew
Multi- family residence of units
❑Subdivision of lots
[II General service
Other
41s ls".
1 1
on a pole Eon the ground
houSei+ 3110 ""1e
Main disconnect size
Date
Zo C)
❑120/208 3ph 277/480 3ph
0480 3W 3ph Other
}Standard residential loads (Lighting refrigerator dishwasher washer)
A/C ton) 'Range /Oven Hot Tub
Clothes Dryer /eating Pumps Hp)
Water Heater Elevator Hp) Other
c I e l 0
ED FORM TO 321 E 5TH STREET PORT ANGELES WA
Public Works Utilities Department (360) 417 -4700
City Electrical Inspector (360) 417 -4735
amps
98362
WS
WF
24
3F SECT
f, 6 W/3-LBC4
it J-35
16
Hi
1p»
01'
C-271
\t, 100A ch3
'fay
2Ti,' A
1P
0
0
0
0
0
PVCFe
15
916
,A4
22
0 .2 J-201
g
13
11
12
23
35 0 TPX 1
mt.
24
0
0
25
village cir
21
2 2
26
0
0
9
11< _4
0 -0
X
27
It
2003
20022 g,
20O
4"PVC Eindberg-R71_
1/0 ALCN 2"PVC
3
1002e:
z
0
7 350. TPX
1"olfr
.1
201
1023
889
15
45
0
Clallam County Assessor Treasurer Property Details 66743 HOUSING AUTHORIT Page 1 of 3
Clallam County Assessor Treasurer
Property Search Results 66743 HOUSING AUTHORITY OF CLALLAM for Year 2010 2011
Property
Account
Property ID: 66743 Legal Description PENINSULA VILLAGE V15
P6 LOT 11 12A
Geographic ID: 0630135701100000 Agent Code
Type. Real
Tax Area. 0010 PA 121 PORT ST CNTY H2 L Land Use Code 97
Open Space. N DFL N
Historic Property" N Remodel Property' N
Multi- Family Redevelopment: N
Location
Address: 1933 VILLAGE CIR Mapsco
PORT ANGELES WA
Neighborhood: Exempt All Exmpt Reference Map ID"
Neighborhood CD: 50110030
Owner
Name. HOUSING AUTHORITY OF CLALLAM Owner ID: 31369
Mailing Address. 2603 S FRANCIS ST Ownership 100 0000000000%
PORT ANGELES WA 98362 -6710
Exemptions: EX
Taxes and Assessments Due
Property Tax Information as of 05/20/2010
Amount Due if Paid on.
Statement
Year ID Taxing Jurisdiction
2010 48776 ST SCH STATE SCHOOL
2010 48776 CC -GEN COUNTY
2010 48776 PORT PORT
2010 48776 PORT ANG PORT ANGELES
2010 48776 SD #121 SCHOOL DISTRICT #121
2010 48776 NTH OLY LIB NORTH OLYMPIC LIBRARY
2010 48776 HOSP #2 HOSPITAL #2
2010 48776 WSMET PK DIST WILLIAM SHORE MET PARK DIST
2010 48776 WEED_CONTROL WEED CONTROL
2010 48776 TOTAL.
2009 667432008 ST SCH STATE SCHOOL
2009 667432008 CC -GEN COUNTY
2009 667432008 PORT PORT
2009 667432008 PORT ANG PORT ANGELES
2009 667432008 SD #121 SCHOOL DISTRICT #121
2009 667432008 NTH OLY LIB NORTH OLYMPIC LIBRARY
2009 667432008 HOSP #2 HOSPITAL #2
2009 667432008 FIRE_PATROL FIRE PATROL
2009 667432008 WEED_CONTROL WEED CONTROL
First Second
Half Half
Base I Base Base Amount
Due Due Penalty Interest Paid Due
$0 00 $0 00 $0 00 $0 00 $0 00 $0 00
$0 00 $0 00 $0 00 $0 00 $0 00 $0 00
$0 00 $0 00 $0 00 $0 00 $0 00 $0 00
$0 00 $0 00 $0 00 $0 00 $0 00 $0 00
$0 00 $0 00 $0 00 $0 00 $0 00 $0 00
$0 00 $0 00 $0 00 $0 00 $0 00 $0 00
$0 00 $0 00 $0 00 $0 00 $0 00 $0 00
$0 00 $0 00 $0 00 $0 00 $0 00 $0 00
$1 63 $0 00 $0 00 $0 00 $1 63 $0 00
$1.63 $0.00 $0.00 $0.00 $1.63 $0.00
$0 00 $0 00 $0 00 $0 00 $0 00 $0 00
$0 00 $0 00 $0 00 $0 00 $0 00 $0 00
$0 00 $0 00 $0 00 $0 00 $0 00 $0 00
$0 00 $0 00 $0 00 $0 00 $0 00 $0 00
$0 00 $0 00 $0 00 $0 00 $0 00 $0 00
$0 00 $0 00 $0 00 $0 00 $0 00 $0 00
$0 00 $0 00 $0 00 $0 00 $0 00 $0 00
$17 90 $0 00 $0 00 $0 00 $17 90 $0 00
$1 63 $0 00 $0 00 $0 00 $1 63 $0 00
http. /vpn.clallam. net. 8084 propertyaccess /Property.aspx ?cid =0 &year= 2010 &prop_id =66 5/20/2010