HomeMy WebLinkAbout1943 Village Cir - BuildingLinda Pangrle
From Ken Dubuc
Sent: Thursday August 11 2011 3 46 PM
To Linda Pangrle
Subject: RE inspections
Linda
Yes, in fact it was done, on July 22, 2011
Thanks for catching that.
Ken
From Linda Pangrle
Sent: Thursday, August 11, 2011 1 12 PM
To Ken Dubuc
Subject: RE inspections
The house is finaled I'd like to archive the permit information Please ask whoever did the inspection on this fire
sprinkler system what date they approved it (or a good approximate), and let me know If it was never inspected, will
it be inspected soon?
Thanks,
Linda
From Ken Dubuc
Sent: Thursday, August 11, 2011 11 54 AM
To: Linda Pangrle
Subject: RE inspections
I did not do the inspections, so I'm assuming the answer is no
Thanks,
ken
From Linda Pangrle
Sent: Thursday, August 11, 2011 10 55 AM
To Ken Dubuc
Subject: RE inspections
Did you also final 1943 Village Circle #11 -461 on the same day?
From Ken Dubuc
Sent: Thursday, August 11, 2011 10 45 AM
To: Linda Pangrle
Subject: inspections
Linda,
Here is some info for you
1925 Village Circle 10 -1514
1929 Village Circle 10 -1513
1933 Village Circle 11 -78
1940 Village Circle 11 -125
1944 Village Circle 11 -126
1119 Village Place 11 -276
1123 Village Place 11 -277
All of these were finaled on 7 22 2011
Thanks,
Ken
2
PREPARED 7/27/11 8 10 52 INSPECTION TICKET PAGE 10
CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 7/27/11
ADDRESS 1943 VILLAGE CIR SUBDIV
CONTRACTOR PHONE
OWNER LORI BROTHERS PHONE (360) 460 3496
PARCEL 06 30 13 5 7 0090 0000
APPL NUMBER 10 00000517 RES NEW SFR
PERMIT BPR 00 BUILDING PERMIT RESIDENTIAL
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
BL1 01 10/11/10 JLL BLDG FOUNDATION FOOTING TIME 09 00
10/11/10 AP October 8 2010 1 19 31 PM 1pangrle
BRUCE 912 0079
FOOTINGS WITH UFR S
MORNING
October 11 2010 4 16 00 PM jlierly
ufr installed /j11
BL2 01 10/13/10 JLL BLDG FOUNDATION STEM WALL TIME 09 00
10/13/10 AP October 12 2010 1 42 00 PM 1pangrle
BRUCE 912 0079
STEMWALL
MORNING
October 13 2010 3 45 01 PM jlierly
BL3 01 4/20/11 JLL BLDG FRAMING
4/20/11 AP April 20 2011 8 19 10 AM 1pangrle
BRUCE 912 0079
SUB FLOOR FRAMING
April 20 2011 3 57 25 PM jlierly
BL9 01 5/17/11 JLL BLDG SHEARWALL
5/19/11 AP May 16 2011 4 42 08 PM 1pangrle
BRUCE 912 0079
'EXTERIOR SHEAR NAILING
May 19 2011 4 49 22 PM jlierly
BAIR 01 6/02/11 JLL BLDG AIR SEAL
6/02/11 AP June 2 2011 9 46 03 AM pbarthol
Bruce 912 0079
June 2 2011 4 01 17 PM jlierly
BL3 02 6/02/11 JLL BLDG FRAMING
6/02/11 AP June 2 2011 9 45 33 AM pbarthol
Bruce 912 0079
June 2 2011 4 01 17 PM jlierly
BLI 01 6/07/11 JLL BLDG INSULATION
6/07/11 AP June 6 2011 1 36 12 PM 1pangrle
BRUCE 912 0079
WALL INSULATION
June 7 2011 4 40 14 PM jlierly
BLDR 01 6/13/11 JLL BLDG DRYWALL IBWP
6/13/11 AP June 13 2011 8 56 14 AM pbarthol
Bruce 912 0079
June 13 2011 5 00 13 PM jlierly
PW99 01 7/19/11 RV PUBLIC WORKS FINAL
7/19/11 IP July 20 2011 7 24 13 AM rvess
July 20 2011 7 24 31 AM rvess
BL99 01 7/27/71 BLDG FINAL
ra July 26 2011 9 24 21 AM 1pangrle
BRUCE 912 0079
CONTINUED ONTO NEXT PAGE
PREPARED 7/27/11 8 10 52 INSPECTION TICKET PAGE 11
CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 7/27/11
ADDRESS 1943 VILLAGE CIR SUBDIV
CONTRACTOR PHONE
OWNER LORI BROTHERS PHONE (360) 460 3496
PARCEL 06 30 13 5 7 0090 0000
APPL NUMBER 10 00000517 RES NEW SFR
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
BUILDING FINAL
PERMIT ME 00 MECHANICAL PERMIT
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RES RESULTS /COMMENTS
ME99 01 7/27/y1
PERMIT PL 00 PLUMBING PERMIT
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
PL6 01 4/14/11 PB PLUMBING WATER SUPPLY
4/15/11 AP April 14 2011 8 21 08 AM 1pangrle
JOHN 460 6902
WATER SUPPLY LINE
April 15 2011 8 48 33 AM pbarthol
PL2 01 5/24/11 JLL PLUMBING ROUGH IN
5/24/11 AP May 24 2011 8 59 17 AM pbarthol
John 460 6902
May 24 2011 4 50 14 PM jlierly
PL99 01 7/27/11 PLUMBING FINAL
I July 26 2011 9 26 37 AM 1pangrle
BRUCE 912 0079
PLUMBING FINAL
MECHANICAL FINAL
July 26 2011 9 24 36 AM 1pangrle
BRUCE 912 0079
MECHANICAL FINAL
COMMENTS AND NOTES
PREPARED 6/13/11 10 45 17 INSPECTION TICKET PAGE 2
CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 6/13/11
ADDRESS 1943 VILLAGE CIR SUBDIV
CONTRACTOR PHONE
OWNER LORI BROTHERS PHONE (360) 460 3496
PARCEL 06 30 13 5 7 0090 0000
APPL NUMBER 10 00000517 RES NEW SFR
PERMIT BPR 00 BUILDING PERMIT RESIDENTIAL
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
BL1 01 10 /11 /10 JLL BLDG FOUNDATION FOOTING TIME 09 00
10 /11 /10 AP October 8 2010 1 19 31 PM 1pangrle
BRUCE 912 0079
FOOTINGS WITH UFR S
MORNING
October 11 2010 4 16 00 PM jlierly
ufr installed/j11
BL2 01 10/13/10 JLL BLDG FOUNDATION STEM WALL TIME 09 00
10/13/10 AP October 12 2010 1 42 00 PM 1pangrle
BRUCE 912 0079
STEMWALL
MORNING
October 13 2010 3 45 01 PM jlierly
BL3 01 4/20/11 JLL BLDG FRAMING
4/20/11 AP April 20 2011 8 19 10 AM 1pangrle
BRUCE 912 0079
SUB -FLOOR FRAMING
April 20 2011 3 57 25 PM jlierly
BL9 01 5/17/11 JLL BLDG SHEARWALL
5/19/11 AP May 16 2011 4 42 08 PM 1pangrle
BRUCE 912 0079
EXTERIOR SHEAR NAILING
May 19 2011 4 49 22 PM jlierly
BAIR 01 6/02/11 JLL BLDG AIR SEAL
6/02/11 AP June 2 2011 9 46 03 AM pbarthol
Bruce 912 0079
June 2 2011 4 01 17 PM jlierly
BL3 02 6/02/11 JLL BLDG FRAMING
6/02/11 AP June 2 2011 9 45 33 AM pbarthol
Bruce 912 0079
June 2 2011 4 01 17 PM jlierly
BLI 01 6/07/11 JLL BLDG INSULATION
6/07/11 AP June 6 2011 1 36 12 PM 1pangrle
BRUCE 912 0079
WALL INSULATION
June 7 2011 4 40 14 PM jlierly
BLDR O1 6/13/11 BLDG DRYWALL I8WP
June 13 2011 8 56 14 AM pbarthol
Bruce 912 0079
COMMENTS AND NOTES
PREPARED 6/07/11 8 44 22 INSPECTION TICKET PAGE 1
CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 6/07/11
ADDRESS 1943 VILLAGE CIR SUBDIV
CONTRACTOR PHONE
OWNER LORI BROTHERS PHONE (360) 460 3496
PARCEL 06 30 13 5 7 0090 0000
APPL NUMBER 10 00000517 RES NEW SFR
PERMIT BPR 00 BUILDING PERMIT RESIDENTIAL
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
BL1 01 10 /11 /10 JLL BLDG FOUNDATION FOOTING TIME 09 00
10 /11 /10 AP October 8 2010 1 19 31 PM 1pangrle
BRUCE 912 0079
FOOTINGS WITH UFR S
MORNING
October 11 2010 4 16 00 PM jlierly
ufr installed/j11
BL2 01 10/13/10 JLL BLDG FOUNDATION STEM WALL TIME 09 00
10/13/10 AP October 12 2010 1 42 00 PM 1pangrle
BRUCE 912 0079
STEMWALL
MORNING
October 13 2010 3 45 01 PM jlierly
BL3 01 4/20/11 JLL BLDG FRAMING
4/20/11 AP April 20 2011 8 19 10 AM 1pangrle
BRUCE 912 0079
SUB -FLOOR FRAMING
April 20 2011 3 57 25 PM jlierly
BL9 01 5/17/11 JLL BLDG SHEARWALL
5/19/11 AP May 16 2011 4 42 08 PM 1pangrle
BRUCE 912 0079
EXTERIOR SHEAR NAILING
May 19 2011 4 49 22 PM jlierly
BAIR 01 6/02/11 JLL BLDG AIR SEAL
6/02/11 AP June 2 2011 9 46 03 AM pbarthol
Bruce 912 0079
June 2 2011 4 01 17 PM jlierly
BLDG FRAMING
June 2 2011 9 45 33 AM pbarthol
Bruce 912 0079
June 2 2011 4 01 17 PM jlierly
BLI O1 6/07/11 BLDG INSULATION
June 6 2011 1 36 12 PM 1pangrle
BRUCE 912 0079
WALL INSULATION
BL3 02 6/02/11 JLL
6/02/11 AP
COMMENTS AND NOTES
PREPARED 6/02/11 9 49 11 INSPECTION TICKET
CITY OF PORT ANGELES INSPECTOR JAMES LIERLY
ADDRESS 1943 VILLAGE CIR
CONTRACTOR
OWNER
PARCEL
APPL NUMBER
PERMIT
TYP /SQ
BL1 01
BL2 01 10/13/10 JLL
10/13/10 AP
BL3 01 4/20/11 JLL
4/20/11 AP
BL9 01 5/17/11 JLL
5/19/11 AP
BAIR 01 6/02/11
BL3 02 6/02/11
LORI BROTHERS
06 30 13 5 7 0090 0
10 00000517 RES NEW
BPR 00 BUILDING PERMIT
REQUESTED INSP
COMPLETED RESULT
10 /11 /10 JLL
10 /11 /10 AP
000
SFR
RESIDENTIAL
DESCRIPTION
RESULTS /COMMENTS
BLDG FOUNDATION FOOTING TIME 09 00
October 8 2010 1 19 31 PM 1pangrle
BRUCE 912 0079
FOOTINGS WITH UFR S
MORNING
October 11 2010 4 16 00 PM jlierly
ufr installed/j11
BLDG FOUNDATION STEM WALL TIME 09 00
October 12 2010 1 42 00 PM 1pangrle
BRUCE 912 0079
STEMWALL
MORNING
October'13 2010 3 45 01 PM jlierly
BLDG FRAMING
April 20 2011 8 19 10 AM 1pangrle
BRUCE 912 0079
SUB FLOOR FRAMING
April 20 2011 3 57 25 PM jlierly
BLDG SHEARWALL
May 16 2011 4 42 08 PM 1pangrle
BRUCE 912 0079
EXTERIOR SHEAR NAILING
May 19 2011 4 49 22 PM jlierly
BLDG AIR SEAL
June 2 2011 9 46 03 AM pbarthol
Bruce 912 0079
BLDG FRAMING
June 2 2011 9 45 33 AM pbarthol
Bruce 912 0079
COMMENTS AND NOTES
SUBDIV
PHONE
PHONE (360) 460 3496
'1
PAGE 1
DATE 6/02/11
PREPARED 5/24/11 9 58 14 INSPECTION TICKET PAGE 1
CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 5/24/11
ADDRESS 1943 VILLAGE CIR SUBDIV
CONTRACTOR PHONE
OWNER LORI BROTHERS PHONE (360) 460 3496
PARCEL 06 30 13 5 7 0090 0000
APPL NUMBER 10 00000517 RES NEW SFR
PERMIT PL 00 PLUMBING PERMIT
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
PL6 01 4/14/11 PB
4/15/11 AP
PL2 01 5/24/11
I-
PLUMBING WATER SUPPLY
April 14 2011 8 21 08 AM 1pangrle
JOHN 460 6902
WATER SUPPLY LINE
April 15 2011 8 48 33 AM pbarthol
PLUMBING ROUGH IN
May 24 2011 8 59 17 AM pbarthol
John 460 6902
COMMENTS AND NOTES
Application Number
Application pin number
Property Address
ASSESSOR PARCEL NUMBER
Tenant nbr name
Application type description
Subdivision Name
Property Use
Property Zoning
Application valuation
Application desc
FIRE SPRINKLER SYSTEM
Owner
Permit
Additional desc
Permit pin number
Permit Fee
Issue Date
Expiration Date
Fee summary
Permit Fee Total
Plan Check Total
Grand Total
CITY OF PORT ANGELES
FIRE DEPARTMENT PERMIT
321 East 5th Street, Port Angeles, WA 98362
11 00000461
502271
1943 VILLAGE CIR
06 30 13 5 7 0090 0000
LORI K BROTHERS
FIRE SPRINKLER SYSTEM
RESIDENTIAL HIGH DENSITY
1875
Contractor
Special Notes and Comments
A full acceptance test will be required for the fire
sprinkler system
All homes in new subdivisions that are outside of the Fire
Department four minute response area shall be equipped with
residential fire sprinkler systems that comply with the
International Fire Code (IFC) and National Fire Protection
Association (NFPA)
Charged Paid Credited
00 00 00
00 00 00
00 00 00
Date 5/19/11
LORI K BROTHERS INNOVATED FIRE SPRINKLERS
PO BOX 3226 81 NEW HAVEN LANE
PORT ANGELES WA 98362 PORT ANGELES
(360) 460 3496 (360) 452 7583
Structure Information 000 000 FIRE SPRINKLER SYSTEM
WA 98362
FIRE SPRINKLER RESIDENTIAL
FIRE SPRINKLER SYSTEM
185629
00 Plan Check Fee 00
5/19/11 Valuation 1875
11/15/11
Due
00
00
00
REPORT SALES TAX
on your state excise tax form
to the City of Port Angeles
(Location Code 0502)
hvicc
This permit becomes null and void if work authorized is not commenced within 180 days, if work is suspended or
abandoned for a period of 180 days afer the work has commenced, or if required inspections have not been requested with
180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be
true and correct. All provisions of recognized standards, laws and ordinances governing this type of work will be compied
with whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel
the provisions of any state or local law regulating the work specified in the permit.
1.)L„,.1/4 j",/
Signature of Contractor or uthorized Agent Date Signature of Owner (if Owner is builder) Date
GENERAL COMMENTS
FIRE PERMIT INSPECTION RECORD
Call 360 417 -4655 for fire inspections. Please provide a minimum 24 -hour notice
or conceal any work before inspected and accepted. Post permit in a conspicuous
KEEP PERMIT CARD AND APPROVED PLANS AT
Date Passed
Inspection Type
FIRE SPRINKLER
Underground piping hydrostatically tested
Underground piping flushed
Interior piping hydrostatically tested
Interior piping inspection
Dry system air tested at 40 psi (24 hours)
Sprinkler final
FIRE ALARM
Rough -in inspection
Alarm final
LP -GAS
Underground piping inspection /pressure test
Above ground piping inspection/pressure test
Tank (container) inspection
Appliance inspection
LP -gas final
UNDERGROUND STORAGE TANK (UST) ABANDONMENT
Removal of flammable /combustible liquids
Tank appropriately abandoned
UST abandonment final
PERMIT OTHER (specify)
permit final
1 -22 -11 Kb I)
JOB SITE
Comments
Completed by Contractor
Test #1
Piping pressure test
Time initiated
Test #2
Piping pressure test
Time initiated
It is unlawful to cover insulate
location.
2/15/00
psi
psi
PREPARED 5/17/11 8 24 45 INSPECTION TICKET PAGE 3
CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 5/17/11
ADDRESS 1943 VILLAGE CIR SUBDIV
CONTRACTOR PHONE
OWNER LORI BROTHERS PHONE (360) 460 3496
PARCEL 06 30 13 5 7 0090 0000
APPL NUMBER 10 00000517 RES NEW SFR
PERMIT BPR .00 BUILDING PERMIT RESIDENTIAL
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
BL1 01 10 /11 /10 JLL BLDG FOUNDATION FOOTING TIME 09 00
10 /11 /10 AP October 8 2010 1 19 31 PM 1pangrle
BRUCE 912 0079
FOOTINGS WITH UFR S
MORNING
October 11 2010 4 16 00 PM jlierly
ufr installed/j11
BL2 01 10/13/10 JLL BLDG FOUNDATION STEM WALL TIME 09 00
10/13/10 AP October 12 2010 1 42 00 PM 1pangrle
BRUCE 912 0079
STEMWALL
MORNING
October 13 2010 3 45 01 PM jlierly
BL3 01 4/20/11 JLL BLDG FRAMING
4/20/11 AP April 20 2011 8 19 10 AM 1pangrle
BRUCE 912 0079
SUB FLOOR FRAMING
April 20 2011 3 57 25 PM jlierly
BL9 01 5/17/11 J�, BLDG SHEARWALL
May 16 2011 4 42 08 PM 1pangrle
BRUCE 912 0079
'EXTERIOR SHEAR NAILING
COMMENTS AND NOTES
r
Applicant or Agent 41 INC. ee, ,eQ
Owner L evv v ✓J
Owner's Address rp, O, (t.Ux 3 2 a td
Contractor /Engineer /A/C /Qz14 0 F-,
Contractor /Engineer's Address 8/ ?/e-.„)
License lA/Al(11 S' 0 4/ g
PROJECT ADDRESS
Parcel Number
Project Type Brief Description. )4
Check all that apply
)<New Construction
Addition
o Remodel
o Repair
o Re -roof
o Demolition
o Sign
o Heat System
Other
Floor Areas
Basement
1 Floor
2nd Floor
3 Floor
Garage
Carport
Covered Porch
Deck
Shed
Other
Total footprint of structures
BUILDING PERMIT
CITY OF PORT ANGELES
Attn. Building Permit Technician
321 E. Fifth St. Port Angeles, WA 98362
(360) 417 -4815 fax (360) 417 -4711
9 f i; ))oL J C t v-cd
Existinalsg. ft.) Posed (sq. ft.)
o Commercial
Max. height of proposed structures ft. Occupancy group
Will a lawn sprinkler system be installed? Occupant load
Will a fire sprinkler system be installed? Construction type
APPLICA TION Print in ink
For City Use Only
Date Received 5-12- I
Permit# It-46
Date Approved
Phone Li!S 2. 7Z 87
Phone y go
Phone 4,.,1 7,5 2,3
Lite f o r-1 e QJL J!.
Expires i" J i
l
Lot 9 Zoning
o Multi- family Industrial
o wall mounted o projecting freestanding awning o other
Total sign area sq ft. Maximum allowed sign area sq. ft.
o Heat pump wood- burning stove o gas fireplace pellet stove other
per sq. ft.
TOTAL VALUATION 7S
sq ft. Lot size sq ft. Lot coverage
of bedrooms
of full baths
of half baths
I have read and completed this application and know it to be true and correct. I am authorized to apply for this permit and
understand that it is my responsibility to determine what permits are required, and to obtain permits prior to working on
projects. L /l K 1/2-%../4 si l�l
T.Forms /Buildin. Division /Bldg Permit Appl. -2006 Code doc
Clallam County Assessor Treasurer Property Details 66741 LORI K BROTHERS fo Page 1 of 2
Clallam County Assessor Treasurer
Property Search Results 66741 LORI K BROTHERS for Year 2011 2012
Property
Account
Property ID'
66741
Legal Description:
Geographic ID 0630135700900000 Agent Code
Type: Real
Tax Area. 0010 PA 121 PORT ST CNTY H2 L WMP Land Use Code 11
Open Space N DFL N
Historic Property' N Remodel Property' N
Multi Family Redevelopment: N
Township' Section:
Range:
Location
Address. 1943 VILLAGE CIR Mapsco
PORT ANGELES, WA 98362
Neighborhood Cycle 5 Res
Neighborhood CD• 10955130
Owner
Name: LORI K BROTHERS
Mailing Address. PO BOX 3226
PORT ANGELES WA 98362
Taxes and Assessment Details
Amount Due if Paid on M.
Property Tax Information as of 05/12/2011
Map ID 2
Exemptions:
LOT 9 PENINSULA
VILLAGE V15 P6
SURVEY V68 P69
Owner ID' 209666
Ownership: 100.0000000000%
y 'Y
3('■ \ei
NOTE. If you plan to submit payment on a future date make sure you enter the date and
click RECALCULATE to obtain the correct total amount due
First Second
Half Half
Base Base
I Year Statement ID Taxing Jurisdiction Amt. Amt. Penalty Interest Base Paid Amount Due
2011 160479 ST SCH STATE SCHOOL $53.45 $53 45 $0 00 $0 00 $53 45 $53 45
2011 160479 CC GEN COUNTY CLALLAM $29.51 $29.51 $0.00 $0.00 $29.51 $29.51
l 2011 160479 SD #121 SCHOOL DISTRICT #121 $69.88 $69.87 $0 00 $0 00 $69.88 $69.87
2011 160479 CITY PORT ANG CITY OF PORT ANGELES $68 13 $68 11 $0.00 $0.00 $68 13 $68.11
2011 160479 PORT PORT OF PORT ANGELES $4 16 $4 15 $0.00 $0.00 $4 16 $4 15
2011 160479 NTH OLY LIB NORTH OLYMPIC LIBRARY $12.38 $12.37 $0 00 $0 00 $12.38 $12.37
2011 160479 HOSP #2 HOSPITAL #2 $12.12 $12.11 $0 00 $0 00 $12.12 $12.111
2011 160479 WSMET PK DIST WILLIAM SHORE MET PARK DIST $3.68 $3.68 $0 00 $0 00 $3.68 $3.68
2011 160479 CITY STORMWATER CITY STORMWATER $0.00 $0.00 $0.00 _$0.00 $0.00_ $0.00
2011 160479 FIRE_PATROL FIRE PATROL $8_.70 $8.70 $0 00 $0.00 $8. W $8.70
2011 160479 WEED CONTROL WEED CONTROL
ONTROL $0.82 $0.81 $000 $0.00 $0.82 $0 81
12 160479 FP Fee FIRE PATROL COUNTY FEE $0.25 $0.25 $0 00 $0.00 $0.25
$0.25
r 2011 160479 TOTAL. $263.08 $263.01_ $0.00 $0.00 $263.08 $263.01
2010 48774 ST SCH STATE SCHOOL $12.27 $12.26 $0.00 $0.00 $24.53 $0.00
2010 48774 CC -GEN COUNTY CLALLAM $6.54 $6.51 $0 00 $0 00 $13.05 $0 00
2010 48774 SD #121 SCHOOL DISTRICT #121 $15.89 $15.88 $0 00 $0 00 $31 77 $0 00
2010 48774 CITY PORT ANG CITY OF PORT ANGELES $15 12 $15 10 $0 00 $0 00 $30.22 $0 00
2010 48774 PORT PORT OF PORT ANGELES $0.92 $0 91 $0 00 $0.00 $1.83 $0 00
2010 48774 NTH OLY LIB NORTH OLYMPIC LIBRARY $1.90 $1 89 $0 00 $0 00 $3.79 $0 00
2010 48774 HOSP #2 HOSPITAL #2 $2.68 $2.68 $0 00 $0 00 $5.36 $0.00
http. /websrv8 clallam. net /propertyaccess /Property.aspx ?cid =0 &year= 2011 &prop_id =66741 5/12/2011
PREPARED 4/20/11 8 32 55
CITY OF PORT ANGELES
ADDRESS 1943 VILLAGE CIR
CONTRACTOR
OWNER
PARCEL
APPL NUMBER
LORI BROTHERS
06 30 13 5 7 0090 0000
10- 00000517 RES NEW SFR
PERMIT BPR 00 BUILDING PERMIT
REQUESTED INSP
TYP /SQ COMPLETED RESULT
BL1 01 10/11/10 JLL
10/11/10 AP
BL2 01 10/13/10 JLL
10/13/10 AP
BL3 01 4/20/11
RESIDENTIAL
DESCRIPTION
RESULTS /COMMENTS
BLDG FOUNDATION FOOTING TIME 09 00
October 8 2010 1 19 31 PM 1pangrle
BRUCE 912 0079
FOOTINGS WITH UFR S
MORNING
October 11 2010 4 16 00 PM jlierly
ufr installed /j11
BLDG FOUNDATION STEM WALL TIME 09 00
October 12 2010 1 42 00 PM 1pangrle
BRUCE 912 0079
STEMWALL
MORNING
October 13 2010 3 45 01 PM jlierly
BLDG FRAMING
April 20 2011 8 19 10 AM 1pangrle
BRUCE 912 0079
SUB FLOOR FRAMING
INSPECTION TICKET
INSPECTOR JAMES LIERLY
COMMENTS AND NOTES
SUBDIV
PHONE
PHONE (360) 460 3496
PAGE 3
DATE 4/20/11
PREPARED 4/14/11 8 23 29 INSPECTION TICKET PAGE 4
CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 4/14/11
ADDRESS 1943 VILLAGE CIR SUBDIV
CONTRACTOR PHONE
OWNER EMILY HOAGLAND JACOB WHETHAM PHONE
PARCEL 06 30 13 5 7 0090 0000
APPL NUMBER 10 00000517 RES NEW SFR
PERMIT PL 00 PLUMBING PERMIT
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
PL6 01 4/14/11 JLL PLUMBING WATER SUPPLY
April 14 2011 8 21 08 AM 1pangrle
JOHN 460 6902
WATER SUPPLY LINE
COMMENTS AND NOTES
Linda Pangrle
From
Sent:
To
Subject:
Linda
Bruce asked me to let you know the new owners info for Lot 9 (1943 Village Circle) so it can be changed on
the building permit
Owner
Lori Brothers
PO Box 3226
Port Angeles, WA 98362
360 460 3496
Sarah Martinez [smartinez @hacc- housing org]
Thursday April 14 2011 2 51 PM
Linda Pangrle
Lot 9 Peninsula Village
Let me know if you need any other information
Thanks,
Sarah T Martinez
Self Help Group Coordinator/ Loan Packager and Development Assistant
Housing Authority of the County of Clallam
2603 S Francis Street
Port Angeles, WA 98362
360 452 7631 ext 22
fax 360 452 9468
1
1
Permit 10 1
Date
I phoned the Applicant 3 u Ce_.,
Property Owner
Contractor
I (left a phone message or�isc
13 H
The permit (has expired r will expire soon) Wh,is` the status of this project?
Please call and schedule a final inspection
Or
Submit a 'permit extension request' letter
Or
Let me know if the project is abandoned
t st 6) k r ,Qtet-d/La, st c
vi -03-t wlA
DrUA-G9 a oic C12 (51.A_Nn-QA A4 nalIS
.4ed_arv-\ n 66 r
Lf— f L ►1 any. voi A e -cime
kY eY Yk
v
T.Fonns /Building Division/Project Status Update
PROJECT STATUS UPDATE
at
at
9 —do q
Application Number
Application pin number
Property Address
ASSESSOR PARCEL NUMBER
Application type description
Subdivision Name
Property Use
Property Zoning
Application valuation
Application desc
New house
Owner
EMILY HOAGLAND JACOB WHETHAM
90 S RHODEFER RD A303
SEQUIM WA 98382
Permit
Additional desc
Permit pin number 175950
Permit Fee 145 50
Issue Date 10/21/10
Expiration Date 4/19/11
Qty Unit Charge Per
1 00 110 3000 ECH EL
1 00 35 2000 ECH EL
Fee summary
Permit Fee Total
Plan Check Total
Grand Total
Charged
145
145
10 00001223
070338
1943 VILLAGE
INSPECTION TYPE
DITCH
SERVICE
ROUGH IN
FINAL
COMMENTS
PERMIT WILL EXPIRE SIX (6) MONTHS FROM LAST INSPECTION
Signature of owner or Electrical Contractor X
ELECTRICAL PERMIT
CITY OF PORT ANGELES
360-417-4735
Date 10/21/10
cIR REPORT STATE SALES TAX
06 30 13 5 7 0090 -0000 on your excise tax form
to the City of Port Angeles
(Location Code 0502)
ELECTRICAL ONLY
RESIDENTIAL HIGH DENSITY
0
Contractor
ELECTRICAL NEW RESIDENTIAL
C Paid
50 145 50
00 00
50 145 50
OLYMPIC WIRING INC
9601 PROVOST ROAD NW
SILVERDALE WA 98383
(360) 692 0134
Plan Check Fee
Valuation
R SQFT FIRST 1300
R SQFT ADDITIONAL 500
Credited
00
00
00
DATE
it
b11 /11 AY
712-2 in
RESULTS
00
0
Extension
110 30
35 20
Due
00
00
00
INSPECTOR.
Date:
0'
OCT -20 -2010 11 02A FROM OLYMPIC WIRING (36O)692 -3680
CIty of Port Angeles Permit Application
Building Divtalon/Electrical Inspections
321 East Filth Street P.O. Box 1150
Port Angeles Washington, 98362
Ph: (380) 417.4735 Fax: (300) 417.4711
Date: /O/2%
_11& 2 Single Family Dwelling
Mulli•Family or Commercial'
Commercial Addition 1 Alteration !Remodel Repair'
Plan Review May BeBequired, Please Complete Electrical Plan Review Information Sheet
Job Address: 1 'IL! ti, I I uor'.L.4 Lo,'- 9
Building Square Footage: 1
Description of above 5t e V C'2 P v\ 412 p_
Owner Information
Name:
Mailing Address: )toQ 2 S F D a.nc is sr-
City: Po- I *s State: L &J Zip: qt" 3
Phone:('',/, C7 TO( Fax:
License Exp.
Unit Charge
119.90
145.50
E 204.60
262.20
372.50
2.60
73.50
2.60
92.70
110.30
148.70
167.90
95.90
88.20
95.90
63.90
83.90
119.90
102.30
110.30
35.20
73.50
110.30
56.00
Sly
Renewable Electrical Energy 5KVA System or Less
NO.,/ O First 1300 Square Fl.
0
3.Each Additional 500 Square Ft. or Portion of
Each Outbuilding or Detached Garage
Each Swimming Pool or Hot Tub
Thermostat
/`f,' fin Total
Check
nate: A0 �2D MI Credit Card
TO 13b04174711 P 2
Cad 2 0 200
ELECTRICAL
INSPECTIONS
Contractor Information
Name:
Mailing Addr s: R 1,01 FR 01 %f 2
City' S, /r.oP,rJQ2/ State:W? Zip: 2jt3
Phong3bd &CP ter.-( Fax NA) bQ a s,
Licen /Exp. rDL M rt'x 3/ CO
Total (Qlv Multiplied by Unit Charge)
Service/Feeder 200 Amp.
Service/Feeder 201.400 Amp.
Service/Feeder 401.600 Amp.
ServtcelFeeder 801 -1000 Amp.
Service/Feeder over 1000 Amp.
Branch Chcult WI Service Feeder
Branch Circuit W/O Service Feeder
Each Additional Branch Circuit
Temp. Service/ Feeder 200 Amp.
Temp. Service/Feeder 201 -400 Amp.
Temp. Service/Feeder 401 -600 Amp.
Temp. Service/Feeder 601 -1000 Amp.
Portal to Portal Hourly
Sign/Outline Lighting
Signal Circuit/ Limited Energy Commercial. Additional 1500 $5.00
Signal Circuit/ Limited Energy 18 2 Family Dwelling
Signal Circuit/ Limited Energy Multi-Family Dwelling
Manufactured Home ConnecUon
Signature of owner, electrical contractor or electrical administrator Cash
Owner as defined by RCW.10.29.251. (1) Owner will occupy the structure for two years alter this electrical permit Is financed. (2) Owner le required to hire an electrical contractor 11
above said property is for sale, rent or lease. Permit expires after six months of last Inspection.
After reading the above statement, I hereby certify that I am the owner of the above named property or a licensed electrical contractor. l am making the electrical installation or
alteration In compliance with the electrical laws, N.E.C. RCW. Chapter 19.28, WAG. Chapter 298.488, The City of Port Angeles MunlcIpai Code, and Utility Specifications.
PREPARED 10/13/10 8 29 22 INSPECTION TICKET PAGE 5
CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 10/13/10
ADDRESS 1943 VILLAGE CIR SUBDIV
CONTRACTOR PHONE
OWNER EMILY HOAGLAND JACOB WHETHAM PHONE
PARCEL 06 30 13 5 7 0090 0000
APPL NUMBER 10 00000517 RES NEW SFR
PERMIT BPR 00 BUILDING PERMIT RESIDENTIAL
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
BL1 01 10/11/10 JLL BLDG FOUNDATION FOOTING TIME 09 00
10/11/10 AP October 8 2010 1 19 31 PM 1pangrle
BRUCE 912 0079
FOOTINGS WITH UFR S
MORNING
October 11 2010 4 16 00 PM jlierly
ufr installed/j11
BL2 01 10/13/10 JLL Aft BLDG FOUNDATION STEM WALL TIME 09 00
October 12 2010 1 42 00 PM 1pangrle
BRUCE 912 0079
STEMWALL
MORNING
COMMENTS AND NOTES
PREPARED 10/11/10 8 13 49 INSPECTION TICKET PAGE 2
CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 10 /11 /10
ADDRESS 1943 VILLAGE CIR SUBDIV
CONTRACTOR PHONE
OWNER EMILY HOAGLAND JACOB WHETHAM PHONE
PARCEL 06 30 13 5 7 0090 0000
APPL NUMBER 10 00000517 RES NEW SFR
PERMIT BPR 00 BUILDING PERMIT RESIDENTIAL
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
BL1
01 10 /1q /10
BLDG FOUNDATION FOOTING TIME 09 00
October 8 2010 1 19 31 PM 1pangrle
BRUCE 912 0079
FOOTINGS WITH UFR S
MORNING
COMMENTS AND NOTES
A 314,913/ ei
Application Number
Application pin number
Property Address
ASSESSOR PARCEL NUMBER
Application type description
Subdivision Name
Property Use
Property Zoning
Application valuation
Application desc
1 152 SF SFR 308 SF GARAGE 39 SF CVRD PORCH
Owner
EMILY HOAGLAND JACOB WHETHAM
90 S RHODEFER RD A303
SEQUIM WA 98382
Permit
Additional desc
Permit pin number
Permit Fee
Issue Date
Expiration Date
T' \Policies \1 102 15 [10/08]
Qty Unit Charge Per
1 00 55 0000 HR PW INSPECTION
Qty Unit Charge Per
1 00 420 0000 EA PW WATER METER DROP IN
di CA''')/—
CITY OF PORT ANGELES
PUBLIC WORKS UTILITIES
321 EAST 5TH STREET PORT ANGELES, WA 98362
10 00000517
081993
1943 VILLAGE CIR
06 30 13 5 7 0090 0000
RES NEW SFR
RESIDENTIAL HIGH DENSITY
107628
Contractor
OWNER
Structure Information 000 000 1 152 SF SFR 308 SF GAR, 39 CVRD PORCH
Other struct into TOTAL LOT COVERAGE 27 80
CONSTRUCTION TYPE VB
FIRE SPRINKLERS REQUIRED YES
NUMBER OF STORIES 1 00
LOT SIZE 5379 00
PROPOSED LOT COVERAGE 1499 00
TOTAL LOT COVERAGE 1499 00
NUMBER OF UNITS 1 00
PUBLIC WORKS INSPECTION
DRIVEWAY INSPECTION
166363
55 00 Plan Check Fee
9/30/10 Valuation
3/29/11
Date 9/30/10
00
0
Extension
55 00
Permit PUBLIC WORKS RES WATER SERV
Additional desc 3/4 DROP IN WATER METER
Permit pin number 166330
Permit Fee 420 00 Plan Check Fee 00
Issue Date 9/30/10 Valuation 107628
Expiration Date 3/29/11
Extension
420 00
Permit PUBLIC WORKS STORMWATER
Additional desc STORMWATER CONNECTION
Permit pin number 166355
Permit Fee 135 00 Plan Check Fee 00
Issue Date 9/30/10 Valuation 107628
REPORT SALES TAX
on your state excise tax form
to the City of Port Angeles
(Location Code 0502)
Separate Permits are required for electrical work, SEPA, Shoreline ESA, utilities private and public improvements This permit becomes
null and void if work or construction authorized is not commenced within 180 days if construction or work is suspended or abandoned
for a period of 180 days after the work as commenced or if required inspections have not been requested within 180 days from the last
inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of
laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not
presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construction.
Signature of Contractor /r /uthorized Agent Date Signature of Owner (if owner is builder) Date
CALL 417 -4831 FOR UTILITY INSPECTIONS PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE IT IS UNLAWFUL TO COVER,
INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT IN A CONSPICUOUS LOCATION
PW UTILITIES (Engineering Division)
WATERLINE METER
SEWER CONNECTION
SANITARY
STORM
SITE DRAINAGE
SITE EROSION CONTROL
PARKING
SIDEWALK
CURB GUTTER
DRIVEWAY APPROACH
BACK -FLOW DEVICE
KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE
INSPECTION TYPE DATE ACCEPTED COMMENTS
CONSTRUCTION R.W PW'
ENGINEERING 417 -4831
FIRE 417 -4653 I
PLANNING DEPT 417 -47`0
BUILDING 417 -4815
T ,Policies \1102 1 [10/08]
RESIDENTIAL
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE
DATE YES NO COMMERCIAL DATE ACCEPTED
YES I NO
PERMIT INSPECTION RECORD
YES
NO
CONSTRUCTION R.W
PW ENGINEERING
I FIRE DEPT
I PLANNING DEPT
I BUILDING
Application Number 10 00000517
Application pin number 081993
Expiration Date 3/29/11
Qty Unit Charge Per
1 00 135 0000 EA SAN SEW STM CON OTHER
CITY OF PORT ANGELES
PUBLIC WORKS UTILITIES
321 EAST 5TH STREET PORT ANGELES, WA 98362
Permit SANITARY SEWER HOOK UP
Additional desc
Permit pin number 166371
Permit Fee 150 00 Plan Check Fee 00
Issue Date 9/30/10 Valuation 107628
Expiration Date 3/29/11
Qty Unit Charge Per
1 00 150 0000 EA SAN SEWER HOOKUP
Special Notes and Comments
May 25 2010 8 38 30 AM rbecker
If you are installing a closed fire system you will ned to
install double check backflow assembly If you are
installing an open fire system you will not need to install
a backflow assembly
If you have any question call Ron becker at 417 4886 or
E mail me at rbecker@cityofpa us
Address numbers shall be plainly visible from the street
Address numbers shall be a minimum of six inches high and be
of contrasting color from the background
All homes in new subdivisions that are outside of the Fire
Department four minute response area shall be equipped with
residential fire sprinkler systems that comply with the
International Fire Code (IFC) and National Fire Protection
Association (NFPA)
This project will require seperate permit and fire
sprinkler plans for review
Call for cover inspection for all sprinkler installations
May 25 2010 10 56 52 AM sroberds
The proposal will result in a new sfr in the RHD for a total
of 28% lot coverage and 40% site coverage No land use
issues anticipated
Electrical load calculations and electrical permits are
required
All connections to City storm drain facilities require an
inspection by Public Works and Utilities Engineering prior
cover Notice will be given 48 hours in advance of
commencing work
Sanitary sewer connection inspection is required by
Public Works prior to back fill of ditch 24 hour advance
notice is required
Construct driveway to City Standards Concrete with exposed
aggregate or other non standard finishes(including colors or
dyes)are not allowed in the City road right of way Broom
finish only An inspection by Public Works Engineering is
required prior to pouring concrete
Page 2
Date 9/30/10
Extension
135 00
Extension
150 00
REPORT SALES TAX
on your state excise tax form
to the City of Port Angeles
(Location Code 0502)
Separate Permits are required for electrical work, SEPA, Shoreline ESA, utilities, private and public improvements This permit becomes
null and void if work or construction authorized is not commenced within 180 days if construction or work is suspended or abandoned
for a period of 180 days after the work as commenced or if required inspections have not been requested within 180 days from the last
inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of
laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not
presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construction
Signature of Contractor or Authorized Agent Date Signature of Owner (if owner is builder) Date
T \Policies\ 1 102 15 [10/081
CALL 417 -4831 FOR UTILITY INSPECTIONS PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE IT IS UNLAWFUL TO COVER,
INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED POST PERMIT IN A CONSPICUOUS LOCATION
INSPECTION TYPE DATE ACCEPTED
PW UTILITIES (Engineering Division)
WATERLINE METER
SEWER CONNECTION
SANITARY
STORM
SITE DRAINAGE
SITE EROSION CONTROL
PARKING
SIDEWALK
CURB GUTTER
DRIVEWAY APPROACH
BACK -FLOW DEVICE
RESIDENTIAL
CONSTRUCTION R.W PW/
ENGINEERING 417 -4831
I FIRE 417 -4653
I PLANNING DEPT 417 -4750
BUILDING 417 -4815
T \Policies\1102 15 [10 /08]
PERMIT INSPECTION RECORD
KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE
YES 1 NO
I I
I I
I I
I I
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE
DATE YES NO COMMERCIAL DATE ACCEPTED
Y ES I NO
CONSTRUCTION R.W
PW ENGINEERING
1 FIRE DEPT
I PLANNING DEPT
I BUILDING
COMMENTS
I I 1
I I 1
I I I I
I 1 1 1
Application Number
Application pin number
Other Fees
Fee summary
Permit Fee Total 760 00 760 00 00 00
Plan Check Total 00 00 00 00
Other Fee Total 4734 50 4734 50 00 00
Grand Total 5494 50 5494 50 00 00
Separate Permits are required for electrical work, SEPA, Shoreline ESA, utilities private and public improvements This permit becomes
null and void if work or construction authorized is not commenced within 180 days if construction or work is suspended or abandoned
for a period of 180 days after the work as commenced or if required inspections have not been requested within 180 days from the last
inspection I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of
laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not
presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construction.
Signature of Contractor or Authorized Agent Date Signature of Owner (if owner is builder) Date
T \Policies\ 1102 15 [10/08]
CITY OF PORT ANGELES
PUBLIC WORKS UTILITIES
321 EAST 5TH STREET PORT ANGELES, WA 98362
10 00000517
081993
RES UNDERGRND SERVICE FEE 770 00
SEWER SYSTEM DELV CHARGE 1980 00
STATE SURCHARGE 4 50
PW WATER SYSTEM USE FEE 1980 00
Charged Paid Credited Due
Page 3
Date 9/30/10
REPORT SALES TAX
on your state excise tax form
to the City of Port Angeles
(Location Code 0502)
CALL 417 -483 FOR UTILITY INSPECTIONS PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAWFUL TO COVER,
INSULATE OR CONCEAL 9NY WORK BEFORE INSPECTED 9ND ACCEPTED POST PERMIT IN A CONSPICUOUS LOCATION
SITE EROSION CONTROL
PARKING
SIDEWALK
CURB GUTTER
PW UTILITIES (Engineering Division)
WATERLINE METER
SEWER CONNECTION
SANITARY
STORM
SITE DRAINAGE
DRIVEWAY APPROACH
BACK -FLOW DEVICE
T \Policies \110' 1 [10/081
INSPECTION TYPE DATE ACCEPTED COMMENTS
RESIDENTIAL
CONSTRUCTION R.W PW/
ENGINEERING 417 48:31
FIRE 417 4653
PLANNING DEPT 417 4750
BUILDING 417 -4815
PERMIT INSPECTION RECORD
KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE
YES NO
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE
DATE YES NO COMMERCIAL DATE ACCEPTED
YES 1 NO
CONSTRUCTION R.W
PW ENGINEERING
I FIRE DEPT
I PLANNING DEPT
I BUILDING
I I I
I I I
I I
I
i 11417/414":‘.: ow- :I
Date
CITY OF PORT ANGELES
DEPARTMENT OF COMMUNITY ECONOMIC DEVELOPMENT BUILDING DIVISION
321 EAST 5TH STREET PORT ANGELES, WA 98362
Application Number
Application pin number
Property Address
ASSESSOR PARCEL NUMBER
Application type description
Subdivision Name
Property Use
Property Zoning
Application valuation
10 00000517
081993
1943 VILLAGE CIR
06 30 13 5 7 0090 0000
RES NEW SFR
RESIDENTIAL HIGH DENSITY
107628
Application desc
1 152 SF SFR 308 SF GARAGE 39 SF CVRD PORCH
Owner
EMILY HOAG
90 S RHODEF
SEQUIM
4 00
1 00
8 00
Structure Information
Other struct info
Permit
Additional desc
Permit pin number
Permit Fee
Issue Date
Expiration Date
JACOB WHETHAM
A303
WA 98382
Qty Unit Charge Per
8 00 5 6000 THOU
Permit
Additional desc
Permit pin number 165878
Permit Fee 208 05
Issue Date 9/30/10
Expiration Date 3/29/11
Qty Unit Charge Per
7 2500 EA
10 6500 EA
14 8000 EA
Permit PLUMBING PERMIT
7/5 5 D/ o /ire t {'t'1 c'C'e fO t
T:Forms /Building Division /Building Permit
Contractor
OWNER
000 000 1 152 SF SFR, 308 SF GAR
TOTAL W LOT COVERAGE
CONSTRUCTION TYPE
FIRE SPRINKLERS REQUIRED
NUMBER OF STORIES
LOT SIZE
PROPOSED LOT COVERAGE
TOTAL LOT COVERAGE
NUMBER OF UNITS
BUILDING PERMIT RESIDENTIAL
1 152 SF SFR 308 SF GARAGE
165860
1065 05
9/30/10 Valuation
3/29/11
BASE FEE
BL -100 001 500K (5 60 PER K)
MECHANICAL PERMIT
Plan Check Fee
Valuation
Date
Print Name Signature of Contractor or Authorized Agent
9/30/10
39 CVRD PORCH
27 80
VB
YES
1 00
5379 00
1499 00
1499 00
1 00
692 28
107628
Extension
1020 25
44 80
Plan Check Fee 00
Extension
BASE FEE 50 00
ME VENT FAN (SINGLE DUCT) 29 00
ME STOVE /FIREPLACE /MISC APP 10 65
ME HEATER(SUSP /WALL /FLOOR MTD) 118 40
REPORT SALES TAX
on your state excise tax form
to the City of Port Angeles
(Location Code 0502)
yl
t�n� �r`PXS
Lori `rO 51-1-10
pp 50 a$3O2
W
3(0
0
keti\
Separate Separate Permits are required for electrical work, SEPA, Shoreline ESA, utilities private and public improvements This permit becomes
null and void if work or construction authorized is not commenced within 180 days if construction or work is suspended or abandoned
for a period of 180 days after the work has commenced or if required inspections have not been requested within 180 days from the
last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions
of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does
not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construction.
Signature of Owner (if owner is builder)
Inspection Type Date
FOUNDATION
Footings
Stemwall
Foundation Drainage Downspouts
Piers
Post Holes (Pole Bldgs.)
PLUMBING
Under Floor Slab
Rough -In
Water Line (Meter to Bldg)
Gas Line
Back Flow Water
AIR SEAL.
Walls
Ceiling
FRAMING.
Joists Girders Under Floor
Shear Wall Hold Downs
Walls Roof Ceiling
Drywall (Interior Braced Panel Only)
T -Bar
INSULATION:
Slab
Wall Floor Ceiling
MECHANICAL.
Heat Pump Furnace FAU Ducts
Rough -In
Gas Line
Wood Stove Pellet Chimney
Commercial Hood Ducts
MANUFACTURED HOMES
Footing Slab
Blocking Hold Downs
Skirting
T:Forms /Building Division /Building Permit
BUILDING PERMIT INSPECTION RECORD
PLEASE PROVIDE A MINIMUM 24 -HOUR NOTICE FOR INSPECTIONS
Building Inspections 417 4815 Electrical Inspections 417 4735
Public Works Utilities 417 4831 Backflow Prevention Inspections 417 4886
IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED
POST PERMIT IN CONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE.
Inspection Type
Electrical 417 -4735
Construction R W PW Engineering 417 -4831
Fire 417 -4653
Planning 417 -4750
Building 417 -4815
Accepted By Comments
1
1
FINAL Date
1
1
PLANNING DEPT Separate Permit #s SEPA.
Parking Lighting 1 ESA.
Landscaping 1 SHORELINE.
FINAL Date Accepted by
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/ USE
Accepted by
Date Accepted By
CITY OF PORT ANGELES
DEPARTMENT OF COMMUNITY ECONOMIC DEVELOPMENT BUILDING DIVISION
321 EAST 5TH STREET PORT ANGELES, WA 98362
Page
Application Number 10 00000517 Date
Application pin number 081993
Additional desc
Permit pin number 165886
Permit Fee 142 00 Plan Check Fee
Issue Date 9/30/10 Valuation
Expiration Date 3/29/11
Qty Unit Charge Per
BASE FEE
9 00 7 0000 EA PL- PLUMBING TRAP
1 00 7 0000 EA PL -WATER LINE
1 00 15 0000 EA PL -SEWER LINE
1 00 7 0000 EA PL -WATER HEATER
Special Notes and Comments
May 25 2010 8 38 30 AM rbecker
If you are installing a closed fire system you will ned to
install double check backflow assembly If you are
installing an open fire system you will not need to install
a backflow assembly
If you have any question call Ron becker at 417 4886 or
E mail me at rbecker@cityofpa us
Address numbers shall be plainly visible from the street
Address numbers shall be a minimum of six inches high and be
of contrasting color from the background
All homes in new subdivisions that are outside of the Fire
Department four minute response area shall be equipped with
residential fire sprinkler systems that comply with the
International Fire Code (IFC) and National Fire Protection
Association (NFPA)
This project will require seperate permit and fire
sprinkler plans for review
Call for cover inspection for all sprinkler installations
May 25 2010 10 56 52 AM sroberds
The proposal will result in a new sfr in the RHD for a total
of 28% lot coverage and 40% site coverage No land use
issues anticipated
Electrical load calculations and electrical permits are
required
All connections to City storm drain facilities require an
inspection by Public Works and Utilities Engineering prior
cover Notice will be given 48 hours in advance of
commencing work
Sanitary sewer connection inspection is required by
Public Works prior to back fill of ditch 24 hour advance
notice is required
Construct driveway to City Standards Concrete with exposed
aggregate or other non standard finishes(including colors or
dyes)are not allowed in the City road right of way Broom
finish only An inspection by Public Works Engineering is
required prior to pouring concrete
Other Fees
2
9/30/10
00
0
Extension
50 00
63 00
7 00
15 00
7 00
RES UNDERGRND SERVICE FEE 770 00
REPORT SALES TAX
on your state excise tax form
to the City of Port Angeles
(Location Code 0502)
Separate Permits are required for electrical work, SEPA, Shoreline ESA, utilities private and public improvements This permit becomes
null and void if work or construction authorized is not commenced within 180 days if construction or work is suspended or abandoned
for a period of 180 days after the work has commenced, or if required inspections have not been requested within 180 days from the
last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions
of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does
not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construction
Date Print Name Signature of Contractor or Authorized Agent Signature of Owner (if owner is builder)
T.Forms /Building Division /Building Permit
Inspection Type
FOUNDATION
Footings
Stemwall
Foundation Drainage Downspouts
Piers
Post Holes (Pole Bldgs
PLUMBING
Under Floor Slab
Rough -In
Water Line (Meter to Bldg)
Gas Line
Back Flow Water
AIR SEAL.
Walls
Ceiling
FRAMING
Joists Girders Under Floor
Shear Wall Hold Downs
Walls Roof Ceiling
Drywall (Interior Braced Panel Only)
T -Bar
INSULATION
Slab
Wall Floor Ceiling
MECHANICAL.
Heat Pump Furnace FAU Ducts
Rough -In
Gas Line
Wood Stove Pellet Chimney
Commercial Hood Ducts
MANUFACTURED HOMES
Footing Slab
Blocking Hold Downs
Skirting
T.Forms /Building Division /Building Permit
BUILDING PERMIT INSPECTION RECORD
PLEASE PROVIDE A MINIMUM 24 -HOUR NOTICE FOR INSPECT IONS
Building Inspections 417 4815 Electrical Inspections 417 4735
Public Works Utilities 417 4831 Backflow Prevention Inspections 417 4886
IT IS UNLAWFUL TO COVER INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED
POST PERMIT IN CONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE.
Date
PLANNING DEPT Separate Permit #s SEPA.
Parking Lighting 1 ESA.
Landscaping 1 SHORELINE.
FINAL INSPECT IONS REQUIRED PRIOR TO OCCUPANCY/ USE
Inspection Type
Electrical 417 -4735
Construction R W PW Engineering 417 -4831
Fire 417 -4653
Planning 417 -4750
Building 417 -4815
Accepted By Comments
FINAL Date Accepted by
FINAL Date
Accepted by
Date Accepted By
Application Number
Application pin number
Other Fees
Fee summary
Permit Fee Total
Plan Check Total
Other Fee Total
Grand Total
Separate Permits are required for electrical work, SEPA, Shoreline ESA, utilities private and public improvements This permit becomes
null and void if work or construction authorized is not commenced within 180 days if construction or work is suspended or abandoned
for a period of 180 days after the work has commenced, or if required inspections have not been requested within 180 days from the
last inspection I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions
of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does
not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construction.
Date Print Name Signature of Contractor or Authorized Agent Signature of Owner (if owner is builder)
T Forms /Building Division /Building Permit
CITY OF PORT ANGELES
DEPARTMENT OF COMMUNITY ECONOMIC DEVELOPMENT BUILDING DIVISION
321 EAST 5TH STREET PORT ANGELES, WA 98362
10 00000517
081993
SEWER SYSTEM DELV CHARGE
STATE SURCHARGE
PW WATER SYSTEM USE FEE
Charged Paid Credited
1415 10 1415 10 00
692 28 692 28 00
4734 50 4734 50 00
6841 88 6841 88 00
Page 3
Date 9/30/10
1980 00
4 50
1980 00
Due
00
00
00
00
REPORT SALES TAX
on your state excise tax form
to the City of Port Angeles
(Location Code 0502)
FOUNDATION
Footings
Stemwall
Foundation Drainage Downspouts
Piers
Post Holes (Pole Bldgs.)
PLUMBING
Under Floor Slab
Rough -In
Water Line (Meter to Bldg)
Gas Line
Back Flow Water
AIR SEAL.
Walls
Ceiling
FRAMING
Joists Girders Under Floor
Shear WalF7Hold Downs
Walls Roof Ceiling
Drywall (Interior Braced Panel Only)
T -Bar
INSULATION:
Slab
Wall Floor Ceiling
MECHANICAL.
Heat Pump Furnace FAU Ducts
Rough -In
Gas Line
Wood Stove Pellet Chimney
Commercial Hood Ducts
MANUFACTURED HOMES
Footing Slab
Blocking Hold Downs
Skirting
PLANNING DEPT Separate Permit #s
Parking Lighting
Landscaping
T.Forms /Building Division /Building Permit
BUILDING PERMIT INSPECTION RECORD
PLEASE PROVIDE A MINIMUM 24 -HOUR NOTICE FOR INSPECT IONS
Building Inspections 417 4815 Electrical Inspections 417 4735
Public Works Utilities 417 4831 Backflow Prevention Inspections 417 4886
IT IS UNLAWFUL TO COVER INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED
POST PERMIT IN CONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE.
Inspection Type Date Accepted By Comments
i0 -1I -10
fl Imo, -10
5 -24 -I
1 -14 —II 1 77
u Fg-
53.0siall8
FINAL Date Accepted by JL-i✓
SEPA.
ESA.
SHORELINE.
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/ USE
Inspection Type
Electrical
Construction R.W PW Engineering
Fire
Planning
Building
417 -4735
417 -4831
417 -4653
417 -4750
417 -4815
l ALL
IFINAL Date 1 Z1� A ccepted by
V
l t Strr, L r
Date Accepted By
7 -27 -I t 1 4 1" &L
Lit
j
co
t
A. SETTLEMENT STATEMENT (HUD -1)
h
OLYMPIC PENINSULA
-Title Gompany-
4 4N oevtW' lnlE RIIURANCB. ESCROWS
C. NOTE. This form is furnished to give you a statement of actual settlement costs. Amounts paid to and by the settlement agent are shown.
marked '(p.o.c.)' were paid outside the closing; they are shown here for informational purposes and are not included in the totals.
D NAME ADDRESS
OF BORROWER.
E. NAME ADDRESS
OF SELLER.
F NAME ADDRESS
OF LENDER.
G PROPERTY LOCATION
101 Contract sales price
102. Personal property
103 Settlement charges to borrower' (line 1400)
104 HACC PRINTS, Engineering, CC, Taxes, Permits, Cr Rn
105 Construction Holdback
107 County taxes to
108. Assessments to
109
111
2,
1I3
114
115
116.
120. Gross Amount Due From Borrower
200. Amounts Paid By Or In Behalf Of Borrower:
201 Deposit or earnest money
202. Principal amount of new loan(s)
203 Existing loan(s) taken subject to
204
205
206. HTF Loan Funds
207
208.
209
Adjustments For Items Unpaid By Seller
210. City/town taxes to
211 County taxes to
212. Assessments to
213
214
215
216.
217
218.
219
220. Total Paid By /For
Borrower
300. Cash At Settlement From/To Borrower:
301 Gross amount due from borrower (line 120)
1 302. Less amount paid by /for borrower (line 220)
303. Cash (LiFROM) tl.. lrO) Borrower
Previous Edition Is Obsolete
Form No. 1581
3/86
Emily Hoagland and Jacob Whetham
90 S. Rhodefer Rd., A303, Seouim, WA 98382
Housing Authority of the County of Clallam
2603 S. Francis St., Port Angeles, WA 98362
USDA Rural Development
1601 E. Front St., Ste B, Port Angeles, WA 98362
1943 Village Circle, Port Angeles, WA 98362
H. SETTLEMENT AGENT Olympic Peninsula Title Company
PLACE OF SETTLEMENT 319 S. Peabody, Suite A, Port Angeles,
I. SETTLEMENT DATE 9/15/2010 Final
J. Summary of Borrower's Transaction
100. Gross Amount Due From Borrower
Adjustments For Items Paid By Seller In Advance:
106. City/town taxes to
58.500.00
2,381.64
9,028.36
94.155.00
WA 98362 (360) 457 -4451
DISBURSEMENT DATE. 9/28/2010
K. Summary of Seller's Transaction
400. Gross Amount Due To Seller
401 Contract sales price
402. Personal property
403
404
405
10.00
159,055.00
4' OMB No. 2502 -0265
B. TYPE OF LOAN
l (-1 FHA 2. FHMA 3. [1] CONV UNINS.
4 i VA 5 L2 CONV INS.
6. FILE NUMBER. 7 LOAN NUMBER
95585 -DS 38691192
8. MORTGAGE INS. CASE NO
Items
Adiustments For Items Paid By Seller In Advance:
406. City/town taxes to
407 County taxes to
408. Assessments to
409
410.
411
412.
413
414
415
416.
164,065 00 420. Gross Amount Due To Seller
500, Reductions In Amount Due To Seller:
501 Excess deposit (see instructions)
502. Settlement charges to seller (line 1400)
503 Existing loan(s) taken subject to
504 Payoff 1st Mtg, Ln.
505 Payoff 2nd Mtg. Ln.
5,000.00 506.
507 HACC SHOP 06 -01
508. HACC Revolved Funds
509
Adjustments For Items Unpaid By Seller
510. City/town taxes to
511 County taxes to
512. Assessments to
513.
514
515
516.
517
518.
519
164,065 00 520. Total Reductions
In Amount Due Seller:
600. Cash At Settlement From/To Seller:
164,065.001 601 Gross amount due to seller (line 420)
164,065.001 602. Less reductions in amount due seller (line 520)
0.001 603. Cash TO) (I_ 1FROM) Seller
Page I of 3
58,500.00
58,500 00
15,000.00)
43,500.00
58,500.00
58,500.00
58,500.00
0 00
SB-4- 3538 -000 -I
HUD -1 (3 -86)
RESPA, HB 4305.2
(8/12/2010) _Linda Pangrle_ Peninsula Village Ifa Page 1u
From 'Sarah Martinez' <smartinez @hacc housing.org>
To 'Linda Pangrle <Lpangrle @cityofpa.us>
Date 8/12/2010 1049 AM
Subject: Peninsula Village Ila
Linda
Here are the owners of the Peninsula Village Ilagrriiin.
Lot 9 1943 Village Circle, Port Angeles WA 98362 Jacob Whetham and Emily Hoagland 90 Rhodefer
Rd A -303 Sequim WA 98382
Lot 12 1929 Village Circle Port Angeles, WA 98362 Alex and Jillian Anderson 335 Harvel Lane Port
Angeles WA 98362
Lot 13 1925 Village Circle, Port Angeles, WA 98362 Michael Anderson and Mary Loucks 40 Blueberry
Place Sequim WA 98382
Thanks!
Sarah T Martinez
Self Help Group Coordinator/ Loan Packager and Development Assistant
Housing Authority of the County of Clallam
2603 S Francis Street
Port Angeles WA 98362
360 452.7631 ext. 22
fax 360 452.9468
Lot 31 1119 Village Place Port Angeles WA 98362 Lisa Brothers 1045 S 3rd Ave 40 Sequim WA
98362
I will send you the other 4 in just a few weeks when all the families have been determined eligible and we
are closer to setting a closing date.
t b
City of Port Angeles
Building Division
321E 5 St.
Port Angeles, WA 98362
5.
RESILEtV 1"!AL PLAN REVIEW UIDELIPNES,
PLAN REVIEW
Items described here are only a guide to common questions and missed items during plan review and
construction. All codes must be complied with (Please read and follow each item) SPECIAL NOTE. Check
item #59 first to see if enaineerina will be needed because of lateral desian. issues.
GENERAL.
1 Final grading of the property must be done prior to final inspection even if owner is doing required retaining
walls Occupancy of the home will not be allowed until there are no slopes steeper than 2 units horizontal
to 1 unit vertical or retaining walls are in place or an accepted soils report is submitted to the City If a
soils report was required initially all requirements of the soils report must be accomplished prior to final
inspection including submittal of all field reports
2. Acrylic stucco products have special requirements Verify such with the manufacturer Requirements may
include tongue and groove foam board under finish control joints special backing boards (sometimes OSB
is NOT allowed) self- furring or furred -out wire or fabric lath and sometimes installation by a certified
installer (certified by the manufacturer) Verify any and all requirements of stucco siding or acrylic stucco
products NO INSPECTION OF LATH OR STUCCO IS REQUIRED, BUT WRITTEN CERTIFICATION
BY A MANUFACTURER'S CERTIFIED INSTALLER MUST BE LEFT AT THE JOB SITE UNTIL FINAL
INSPECTION BY THE CITY
3 Inspection of shear wall nailing roof sheathing to blocking nailing and hold downs must be requested in
addition to standard inspections and before such items are covered up Please specify shear nail roof nail
or hold -down inspection when you request these they may be done simultaneously if ready
4 This plan is approved for OSB or plywood exterior wall sheathing only unless the approved plans at the
time of permit issuance reflect other materials being used Any change to wall sheathing material after
permit-issuance must be submitted to the city for review prior to installation An additional plan review fee
will be assessed
'Tyvek" or equal approved weather resistive barrier (15# felt is OK) required on the exterior side of all
walls regardless of the type of siding used This includes garage walls gable portion of end walls and
cripple walls (at stepped foundation conditions) Apply over exterior sheathing or over studs in single -wall
construction T 1 11 or similar panel siding must have 'Tyvek' or equal over the. studs.
6 Exterior windows and doors shall be flashed with approved materials and caulking Caulked trim material
over the window or door flange is not an acceptable method
7 Overall dimensions of house plan must match site plan dimensions Verify any special requirements for
buildings located close to property lines R302
FILE
1 Building /Handouts /Residential Plan review Gin Iiges (Rev 03- 18 -09)
Page 1 of 8
LIFE SAFETY MISC ITEMS
8 Sleeping rooms must ha an egress window with 5 7 s f net clear opening 24 min height 2n" min
width 44 maximum from floor to window sill Windows must meet all 4 dimensions R310 1
9 Safety or tempered glass shall be used in windows that are (R308 4)
Adjacent to a door (24" arc of either edge of the door in a closed position)
That are closer than 18" to floor (AND individual .pane is more than 9 s f top edge more than 36" a.f f
and walking surface within 36" horizontally of the window in question)
Walls enclosing a tub or shower (AND within 60" of the drain or within _60" of walking. surface) R308 4
Adjacent to stairways landings and ramps within 36" horizontally of a walking surface (AND Tess than
60' a.f f of the walking surface)
Adjacent to stairways within 60" of the bottom tread of the stair in any direction (AND less than 60'
aff)
10 Under -stair areas that are enclosed and accessible must be sheetrocked 1/2" GWB on walls and
underside of the stairway R311 2.2
11 Stairways shall have 10" min tread and7 3/4 max. rise R311 5
12. Provide 36" high guards (with 4" max. spacing on rails) at porches balconies and raised floor surfaces
more than 30' above adjacent ground or floor R312 1
13. Smoke detectors required at all bedrooms hallway or room adjacent to bedrooms and at any ceilings that
are more than 24" above adjacent ceiling All smoke detectors interconnected and hardwired with battery
back -up R313 1
14 Garage /house separation wall is 1/2' GWB door must be 20 min rated or 1. 3/8" solid -core If living space
above use 5/8" GWB Type "X' at the ceiling AND 1/2" GWB at walls that support the floor above .Ducts in
garage must be 26 -gage sheet steel and have no openings in the garage R309
15 Exterior stairways must have a light located near the top landing of the stairway switched from inside (or
have motion activation device) R303 6
16 Minimum room areas must be provided (120 s f min in at least one room 70 s f min all other habitable
rooms 7 foot min dimension in all habitable rooms) R304 1
17 Minimum ceiling heights must be provided (7 foot min with some exceptions) R305 1
FOOTINGS, FOUNDATIONS, AND CRAWL SPACES
18 All footings including exterior isolated pad footings must have a 24 (min) depth from the bottom of the
footing to finished grade R403 1 4 1
19 All footings shall be supported on undisturbed natural soils or engineered fill Any placement of fill material
that will support a structure will require a geotechnical investigation and report submitted to the City prior to
placement of footings R401 2 R403 1
20 Lots shall be graded to drain surface water away from foundations The grade shall fall 6" in the first TEN
feet around the perimeter of the structure R401 3
21 Top surface of footings shall be level Bottom surface of footings shall not have a slope that exceeds (1)
unit vertical in (10) units horizontal Any necessary stepping of the foundation must be approved during
plan review or prior to installation of the foundation R403 1 5
T Building /Handouts /Reside -iti Plan Review Guidelines, (Rev 03- 18 -09)
Page 2 of 8
.1
22. Wood sill plates of all exterior walls interior bearing walls (slab -on- grade) and interior shear walls (slab -on-
grade) must be anchored to foundation or slab with IA X 10' J -bolts with a _2" X 2' X 3/16' plate washer
Anchor bolts to be placed a maximum of 12' and no closer than 3 1 /2" from the ends of the sill. plate Each
piece of sill plate must have a minimum of (2) anchor bolts Anchor bolts shall be spaced no further than 6
feet apart. (Special spacing and sizing conditions may apply at alternate braced wall panels) R403 1 6
'23 6' clearance required from finish grade to foundation mudsill plate R319
24 3 1/2" (min thickness for all concrete slabs -on- grade R506 1
25 .Footing and foundation wall SIZES for two pour system
(Foundation walls NOT over 5 feet in height)
F.00ting supporting single story 12" wide X 6" thick.
Foundation wall supporting single story- 6" thick
Footing supporting two stories- 15" wide X 7' thick.
Foundation wall supporting two stories- 8" thick.
Foundations that support more than two stories require an engineered design
:26. Footing and fnd REINFORCEMENT fortwo. pour system fnd. walls NOT over 5 :feet in height)
(Footings supporting single or two.stories)
One continuous #4 horizontal rebar placed at center of footing with 3" (min) clearance from dirt.
(Foundation walls not over 5 feet in height)
One continuous #4 horizontal rebar placed within the top 12" of the wall
#4 vertical rebar placed at 48 inches o c max (wet set ok) with a 6 -inch 90- degree hook. A
minimum of (2) vertical bars to be placed at front garage wall returns
27 Monolithically poured foundation systems
Bottom of footing shall be 12" wide (min) and extend to 24 below finished grade minimum
Footing shall have either one #5 continuous horizontal rebar placed at center and 8' above bottom of
footing or (2) #4 continuous horizontal rebar placed at center and in the middle third of the footing
measuring vertically
3 1/2" minimum slab thickness
When a monolithic system is used to support heated spaces an R 10 insulation board must be
installed on the outside of the foundation extending from bottom of footing to top of slab Exposed foam
insulation above grade must be protected from damage and sun with approved materials The material
used must extend a minimum of 12" below grade
28 Basement Walls (up to 9 feet) or Stem Walls (over 5 feet) or STEPPED FOUNDATIONS There are
special restrictions for this type of foundation wall under the new code In plan view the length of this type
of wall cannot exceed 35 feet. For stepped foundations this wall cannot exceed 7 feet high otherwise the
floor joists must connect DIRECTLY to the wall (for bracing the foundation wall) WET- SETTING IS NOT
allowed for the alternating hooks into the .footing There are special blocking requirements if any of these
conditions cannot be met (note on the plans!) See R404 1
29 Under -floor pier pads supporting uniform load of wood framed floors shall be 18 "x 18" x 8" (min) Point
loads from other than floor girders will require larger footings sized according to the concentrated load
R403 1 1
30 Beams and /or girders in crawl space must meet span requirements for the loads imposed (from floor joists
and from any point loads) R501 2
T Building /Handouts /Residential Plan Review Guidelines (Rev 03- 18 -09)
Page 3 of 8
31 Access shall be provided to all under -floor spaces Access openings through the floor shall be a minimum
of 18' x 24" Openings through a perimeter wall shall be a minimum of 16' x 24 R408 3
32. Under -floor spaces shall be ventilated by openings providing one (1) square foot of vent area per 150
square feet of crawl space area One such ventilating opening shall be within 3 feet of each corner of the
building R408 2
33 A ground cover of 6 mil black polyethylene or approved equal shall be laid over the .ground within crawl
spaces The.ground cover shall be overlapped 12" and extend to the foundation wall WSEC 502 1 6 7
34 The under -floor grade shall be cleaned of all vegetation and organic material All wood forms and
construction debris shall be removed prior to final inspection R408
35 Thickened -slab footings must be 12" min total depth (top of conc slab to bottom of footing 12" total)
(Revised from.IRC)
36 Foundation cripple walls shall be framed of studs not less in size than the studding above Cripple walls
with a height less than. 14 inches shall be sheathed on one side with a wood structural sheathing or shall
be of solid blocking Cripple walls count as .an additional 'story' for lateral purposes R602 9
FLOOR FRAMING
37 18" (min) clearance beneath all floor joists and 12" (min) clearance beneath floor girders (beams) in crawl
spaces R308
38 Span of all joists (including 2 level joists) must meet minimum live load of 40 psf (general living areas) or
30 psf (sleeping rooms) together with dead load of materials used R301 5 and Table R301 5
39 Span of beams for 2"d level or other supporting elements must meet minimum live and dead load
requirements R301 5
40 Wood posts in the crawl space shall have a connection to the concrete pier and a moisture barrier between
the post and footing (or use pressure- treated posts) R319 R407
41 Solid -sawn floor joists shall be blocked at all bearing points Engineered floor joists shall be installed per
manufacturer's specifications R502.7
42. Cutting drilling and notching of floor joists shall not exceed the limitations in Figure R502 8
43 Cutting drilling and notching of engineered Hoists shall be in accordance with the manufacturer's
specifications R502.8 2
44 All concentrated point loads originating from roof or floor load shall be transferred to bearing footings or
foundation walls Continuous support shall be provided by members that are equal in cross sectional area
to the area of the load imposed and shall not be reduced in size at any point.
45 Wood members supported in concrete or masonry pockets shall have a 1 /2 inch air space provided at tops
sides and ends of the member
46 All foundation plates sills and sleepers bearing on a concrete foundation or slab that is in direct contact
with the ground shall be pressure treated All wood framing members that rest on concrete foundations
and are within 8" of exposed ground shall be pressure treated R319
T Building/Handouts/Residential Plan Review Guidelines (Rev '13- 18 -09)
Page 4 of 8
47 Sawn lumber floor joists shall have 1'h" (min) bearing and shall lap 3" min at intermediate girders
Engineered Hoists shall have 1 3/4 (min) bearing (or per manufacturer's specifications)
48 Floor joists that are parallel to bearing partitions shall be doubled Some heavier Toad cases will require
girder beams or .pony walls Bearing partitions perpendicular to floor joists shall not be offset from the
supporting girder more than the depth of the joists unless the floor joists are of sufficient size to carry the
bad R502 4
49 Floor cantilever spans shall not exceed the depth of the nominal floor joists Floor cantilevers constructed
in accordance with Table R502.3 3 (1) shall be permitted when supporting a light framed bearing wall and
roof only R502 3 3
50 Block in between floor joists beneath all interior braced walls (for walls perpendicular to joists) or align floor
joist with interior braced wall (see item #63 -T)
WALL FRAMING
51 Wall studs taller than 10 feet shall have a stud height analysis by a professional engineer or architect.
Table R602 3 ,5
52. Non-load bearing stud heights shall be in accordance. with Table R602 3 (5)
53 Studs shall be a minimum #3 grade standard grade or stud grade lumber R602.2
54 Where joists trusses or rafters are spaced more than 16" o c. and the bearing studs below are spaced at
24" o c such members shall bear within 5" of the studs below unless the top plates are double 2x6 or a
third plate is added R602 3 3
55 Headers over windows and doors must meet minimum requirements for spans and imposed loads verify
point loads over openings (from trusses or other conditions) and size headers accordingly Headers must
be noted with size type and grade of lumber being used
GENERAL NOTE STATING ALL HEADERS SHALL BE. is acceptable
56 Interior bearing walls must have headers over openings and must be supported to a foundation
57 Top plate splices shall be offset a minimum of 24 inches R602 3 2
58 Fire- blocking required at dropped ceilings soffits coved- ceiling areas and every ten feet horizontally and
vertically at framed walls R602 8
59 Port Angeles is in Seismic Zone D1 Wind zone of 100 MPH Category C (within 1500 ft from shore line is
Category D) per the 2006 IRC When a house is considered IRREGULAR by any ONE the definitions
below the code will NOT allow prescriptive bracing for Seismic Zone C and the entire house must have a
lateral analysis and design-by a licensed engineer (R301 2 2 2 2) Per that section of the code NO MIXING
OF PRESCRIPTIVE AND ENGINEERED LATERAL SYSTEMS IS ALLOWED UNDER THIS NEW 2006
IRC
The following are items that constitute an IRREGULAR BUILDING per the 2006 IRC
A. Exterior braced wall lines must be in one plane vertically from foundation to the uppermost story
(basically the upper floor must match the lower floor footprint) The most common area where
problems like this occur is in a garage with a second floor over it. To qualify for prescriptive bracing
the second floor joists must extend to the exterior walls of the garage If this does NOT occur then
your proposed house is IRREGULAR If the joists do extend to the exterior walls of the garage then
the setback of the second floor walls cannot be more than four (4) feet setback from the garage walls
T Building/Handouts/Residential Plan Review Guidelines (Rev 03- 18 -09)
Page 5 of 8
(see p 44 of the 2006 IRC) Rooms created by roof trusses are OK under this provision (such as
bonus rooms over garages formed by the trusses /rafters)
B The perimeter of all floor diaphragms and all roof diaphragms must be supported on WALLS below If
you have beams holding up. any part of the perimeter of a floor or a roof then your proposed house is
IRREGULAR The most common place you will find this problem is at large covered porches and
patios where the roof is supported only by post and beams Such covered porches and patios also
make the building IRREGULAR Related to this are areas of discontinuous diaphragms .especially
changes in plate line heights which also are considered as separate 'roofs and therefore make the
building .IRREGULAR.
C In any elevation of the exterior the braced walls from an upper .level wall must NOT occur over a
window or door In general this means that the windows of the upper story must align with the
windows of the lower story There are some, exceptions based on up- sizing the header in the window
below. (see 2006 IRC p 44 for details)
D When an opening in a floor or roof (such as a balcony- overlook area or a courtyard area) exceeds the
lesser of 12 feet or 50% of the least dimension then your proposed house is IRREGULAR.
E. When portions of a floor level are vertically offset (such as.a sunken room) then your proposed house
is IRREGULAR This does not apply to a slab -on- grade floor
F When braced wall lines do not occur in two perpendicular directions (such as portions of the house or
garage at an .angle to the rest of the building) then your proposed house is IRREGULAR
G If you have any portion of the above -grade walls that use masonry or concrete construction then your
proposed house is IRREGULAR Stepped foundations that create a daylight basement situation are
OK .under this provision and do not make an irregular structure
60 THIS APPLIES TO ALL. LATERAL BRACING (ITEMS 61 THRU 65) Add up all lengths of braced panels
(4 foot braced panels 2 -8' alt braced panels and 24 or 16' portal frames COUNT as 48' of length each
portal frame counts as a total of 48' of bracing length —not 2 times 48 along the wall in question The
total length of braced walls must be at least 16% of the entire wall length AND the panels must occur at
least every 25 feet along the wall For 1s story of 2 -story house 30% of the entire wall length must be
braced walls Check this for all braced wall lines including INTERIOR WALLS and including the front wall
of a garage if it is not part of another braced wall line (i e the garage sticks out in front of the house more
than 4 feet) See also #65 T below for areas where MORE than 35 feet between wall lines is needed
61 Garage lateral bracing systems with no 2 floor above
H Portal Frame for Garages (16" side panels 8 foot max. high walls 20' side panels 10 foot max.
high walls)
Alternate Braced Walls— single -story condition (2' -8" min width X 10 foot max. height) sheathed on
one side (interior or exterior OK) with min 3/8" OSB or plywood and nailed with 8d common or gals
box nails and blocked at all edges Two (2) anchor bolts in sill plate two (2) hold -down devices
furthest studs (1800 pound capacity hold- downs)
J Alternate Braced Walls —first floor of two -story condition. (2' -8" min width X 10 foot max. height)
sheathed on BOTH interior and exterior sides of wall with min 3/8" OSB or plywood and nailed with 8d
common or galv box nails and blocked at all edges Two (2) anchor bolts in sill plate two (2) hold
down devices furthest studs (3000 pound capacity hold- downs) There are some provisions for plate
fines up to 12 feet high see Table R602 10 6 (basically a wider wall 3 -6' min. length for 12 feet high)
K. Front Garage Panels —no hold -downs required
L. The exterior braced wall lines in a detached or attached garage cannot be more than 35 feet apart in
either direction or interior braced walls must be provided
62. 1 Floor Conditions Four (4) foot solid walls at all corners and at every 25 feet along any braced wall
line OR use one of the methods below
M Portal Frame for a House (slab -on -grade floors ONLY) 16" mu width for one -story structures 24" min
width for first floor of 2 -story
T Building /Handouts /Res■dential Plan Review Guidelines (Rev 03- 18 -09)
Page 6 of 8
N Alternate Braced Walls— single -story condition (2' -8' min width X 10 foot max. height) sheathed on
one side (interior or exterior OK) with min 3/8' OSB or plywood and nailed with 8d common or galv
box nails and blocked at all edges Two (2) anchor bolts in sill plate two (2) hold -down devices
furthest studs (1800 pound capacity hold- downs)
0 Alternate Braced Walls —first floor of two -story condition (2' -8' min width X 10 foot. max height)
sheathed on BOTH interior and exterior sides of wall with min 3/8" OSB or plywood and nailed with 8d
common or galv box nails and blocked at all edges Two (2) anchor bolts in sill plate two (2) hold
down devices furthest studs (3000 pound capacity hold- downs) There are some provisions for plate
lines up to 12 feet high see Table R602 10 6 (basically a wider wall 3 -6' min length for 12 feet high)
P "Simpson" Brand StrongWalls —this method is still available following all the manufacturer's
specifications 'for connections
Q Entire House Sheathed with OSB or Plywood —this method allows smaller side panels than 4 feet in
accordance with Table R602 10 5 CHECK THE OPENING HEIGHTS ADJACENT TO THESE
PANELS!
63. 1s Floor Conditions Braced wall (any of the methods listed above) must start at no more than 12.5 feet
away from the corner of the braced wall lines and then at every 25 feet (min along the wall line
64 2 Floor Conditions Braced walls (either of the methods listed below) must be within 12.5 feet of the
corner of the wall line in question
R. Standard four (4) foot panels on 2nd levels can start at no more than 12.5 feet away from the corner
S Entire House Sheathed with OSB or Plywood —this method allows smaller side panels than 4 feet in
accordance with Table R602 10 5 CHECK THE OPENING HEIGHTS ADJACENT TO THESE
PANELS!
65. Exterior braced wall lines (or together with some interior wall lines) cannot be more than 35 feet apart.
T Certain areas can be up to 50 feet apart between wall lines IF there is additional bracing along the
exterior wall in question (50/35 1 43 more bracing than normally required or in other words 23% of
the total wall in bracing for 1 -story wall 43% of the total wall in bracing for 1 story of a 2 -story house)
R602 10 1 1 Exception 1 and 2.
U Interior Braced Walls can be used when exterior walls are more than 25 feet apart. Interior Braced
Walls are minimum 1/2' GWB both sides of wall for a minimum length of 48" use 5d nails or screws at
7' o c Sole plate of wall must be attached to thickened slab footing (see item #22 above) with 1 -/2
anchor bolt 6' -0' o c or solid blocking (walls perpendicular to joists) or LINE UP JOIST with braced
wall (walls parallel to joists)
66 The roof sheathing MUST nail into SOLID blocking and the block must connect to the double top plate
either with clips or toe nailed (for blocks that are top beveled) with 8d 6' o c For ventilation use not
more than two (2) 2' diameter holes BLOCKING MUST OCCUR AROUND ENTIRE PERIMETER OF
ALL ROOFS Table R602 3 (1) This applies to all houses both engineered AND prescriptive bracing
ROOF ATTIC
67 Truss drawings must show reactions of all girder trusses point loads onto headers must have headers
sized accordingly point loads over 5000 Ibs onto double -top plates must be checked for bearing capacity
Use Simpson brand TBE4 or TBE6 as needed to spread the load
68 Truss bottom chord live load must be minimum of 10PSF (see Table R301 5) Trusses must be sized for
the roof coverings specified on the plans (concrete tile etc) and roof structure must be able to hold up the
roof (beams headers etc sized for roof loads) R802 10 2
69 Ice Shield is required for roofs up to 6 12 (6 12 and over DO NOT require ice shield) R905 2 7 1
T Building /Handouts /Residential P n Reviev, G_iidelines (Rev 03- 18 -09)
Page 7 of 8
70 Attic ventilation must be provided at 1 /150 the attic area or 1/300 of the attic area if 50% of the venting
can be 3 feet above the eave venting (roof jack vents are 49 sq in. /vent. ridge vents at 12 sq in. /foot)
R806 1
71 Attic mechanical equipment, need Tight and switch near opening and electric outlet. Access opening to
such mechanical equipment must be no further than 20 feet from equipment with 22 wide (min) walkway
from access opening to the equipment,
72. Attic access required 22" X 30' min and shall be in hallway or other readily accessible location R807 1
MECHANICAL.
73 Appliances located. in a garage or carport shall be protected from damage from vehicles M1307 3 1
74 Gas appliances located in a garage shall be raised 18" min above finish floor G2408 2 (305 3)
75. Ductwork that extends below grade ,(such as in the garage .floor) shall be encased. in 2' min concrete on all
sides and bottom in addition to the R -10 insulation foam board 603 8 IMC
76 Dryer exhaust ducts shall not exceed 25 feet in length The maximum length of the duct shall be reduced
2 5 feet for each 45- degree bend and 5 feet for each 90- degree bend Longer lengths in accordance with
the manufacturer's listing will be allowed Screws shall not be used to connect any dryer duct materials
M1501 3
77 Flex duct connections to sheet metal transition ducts shall have the inner sleeve taped with approved
materials prior to securing the flex duct with a zip tie or similar fastener 304 IMC
78 Flex duct shall be supported every 4 feet and have no sag that exceeds 1 /2 per foot.
79 All exhaust fan ducts shall be connected to the fan housing and termination fittings with a minimum of 3
sheet metal screws and be sealed with approved tape or mastic.
80 Exhaust fans required 50 cfm in bathrooms 100 cfm in kitchen 50 cfm min. in laundry room and one fan
sized for whole -house ventilation 302.2.2 WSVIAQ
81 Fuel- burning equipment shall not be installed in a closet, bathroom or a room readily usable as a bedroom
82. Water heaters must be .secured to structure with straps around tank at 1/3 points to resist lateral
displacement. M1307 2
PLUMBING
83 Cleanouts shall be installed on all sinks and at the upper end of all building drains including any horizontal
drain branches greater than 5 feet in length from the main line A cleanout shall also be installed on the
exterior of the house within 24 inches of the foundation wall level with final grade and shall have a
threaded type cap installed
84 30' min width for toilet and 24 clear space in front of toilet (UPC)
85. Water heaters pressure relief and the required drain pan shall have a drain that is 1/4 ID copper or cp "c
material NO coil material shall be allowed per code and no reduction in the pipe shall reduce the ID of the
material less than Pex type is a coil material and is not allowed for this application
T Building /Handouts /Residential Plan Review Guidelines (Rev ;3- 18 -09)
Page 8 of 8
^pr eor Coon
Floor Areas
Check all that apply
76.New Construction
Addition
Remodel
Repair
Demolition
Re -roof
I 5Jz4Jto Housing J1v`}ho -r4+1 6f CI&tIar(1) AO 5 Forth cc6, PA, Cti
BUILDING PERMIT ®PPL CA "ION Pant in in -?6 z
Applicant
Property Owner e-
Property Owner's Address
Contractor Qv.) bvi L 4 r
Contractor's Address
License
Shed
Other
Vc i v 0 3$
CITY OF PORT ANGELES
Attn Building Permit Technician
321 E. Fifth St. Port Angeles WA 9
(360) 417 -4815 fax (360) 417 -4711
Expires
PROJECT ADDRESS (c C5 i 0 Q1 e G c'� 2ND
I
Parcel Number G 6 0 13 57o Oct Lot Zoning v_p
Proiect Type Brief Description. Residential Multi- family Commercial Industrial
5 c kR l_
1
ouse7l garage other tear off re -roof lay over one layer
/Heat System Heat pump wood- burning stove gas fireplace pellet stove other
Other b tfJcLA
Existing (sq. ft.) Proposed (sq. ft.)
A For City Use Only
62 00' 1"'� R -te Received 5 -1 8-10
Lk' P -rmit# 10 -5
N �h rate Approved
Pho
do-. Q
L d4 c )P
\VL gMeS cat 11ZH3
0 e (3 rJ tee._ t 0.=1 9
Se- -9 Oa i p ,'z
Phone I
E -mail
w I c-' k 9 e
Basement
1 Floor I 1 Z--
2 Floor
3 Floor
Garage 3 o& 3 0
Carport
Covered Porch 3 9 1
Deck
per sq ft.
9 ,Z 'to vu
TOTAL VALUATION (c7 627--0
m°
Total footprint of structures 1 LA c sq ft. Lot size 53? 9 sq ft. Lot coverage 2 -7ag
Site Coverage the amount of impervious surface or a parcel including structures paved driveways sidewalks, patios
and other impervious surfaces (see PAMC 17 94 135 for exemptions) Site coverage 39:1%
Max height of proposed structures ((0 ft. Occupancy group of bedrooms
Will a lawn sprinkler system be installed? 1 1° Occupant load of full baths Z
Will a fire sprinkler system be installed? e. 5 Construction type of half baths
I have read and completed this application and know it to be true and correct._ I am authorized to apply for this pe it nd understand
that it is my responsibility to determine what permits are required, and to obtain permits pric o wor$)ng on projects
Date -3 ^1 ;r1C) Print Name --4 e` Signature
T.Forms /Building Division /Building permit application
13
23
Lindberg-Rd-
12
24
G
S D11'31%19°1`.(-
5°1 0
i
lir...
P
G34
5
f1 -;t=
P 1 &o
Loc 04660
9/U
0
2i3
T
��l���
�w`
ti
FAX
CITY GOVERNMENT
Site Information. Building Department Use Only.
Lot. 9' Permit 10 51
Address 1 r-1' y U l l IAq C i f'3e. Notes
City 0 i
State W cx Zip c (0 34 C--
Contact. I V—cD4 •e-c r k3r uk. e_
Phone -f77 12 t-13 `l 1'Z 001 1
Phone 2
Table 6 -1
PRESCRIPTIVE REQUIREMENTS FOR GROUP R OCCUPANCY
CLIMATE ZONE 1
(Unlimited Glazing Option Only)
J Wall- Wall
Glazing Glazing,W- Facto "r :Door, wall_
Option. Area' of U= Ceiling ;Above Above Interior ';Exterior
'Floor r Verticalr': Overhead :Factor Ceiling= Grade .Below A;Below
Grade Grade
Group R 3
IV and R -4 0.35 0.58 0.20 R 38 R 30 R 21 R 21 R 10 R 30 R 10
Occupancies
Only
This Project complies with the following-
'V The project is a single- family residence or duplex.
4 The project is a wood frame OR all of the insulation is interior or exterior of the framing.
All building components meet the requirements listed above
I The project will meet all other provisions of the WSEC and VIAQ
The Project will take advantage of the following exceptions to the prescriptive option.
K 602.6 Exception 2. One unlabeled or untested exterior swinging door 24 sq ft. or less, may be
installed per unit for ornamental, security or architect purposes.
Location of the door taking this exception Cbvt oG
602.6 Exception 2. If a door is mostly glass, it should meet the requirement of the vertical
glazing U- factor listed above
Location of the door(s) taking exception
Type of Heat Source. -e J rCC L Wck u S
T Forms /Building Division /Prescriptive Approach Simple Form
PRESCRIPTIVE APPROACH- SIMPLE FORM
For the Washington State Energy Code (2006 Edition)
Climate Zone 1
IJoor
Slab:on
•'Concre.'te
Please complete and return to Public Works Utilities Department
Applicant Information
Permanent service.
Name and address of party
responsible for permanent
service billing?
Contact Information
Site contact:
Contractor
Electrician.
Excavator
Project Type
Ingle- family residence
Commercial
Overhead service
Underground service
Project Information
Street address lot number
Nearest cross street:
Desired connection date. 1
Electrical transformer serving property is on. a pole ['bn the ground
Electrical Load
t 3 5� 13 a r 0, 5e
1 1 s Zsq ft. Main disconnect size 20 amps
n-20/240 1ph 0120/208 3ph 0277/480 3ph
0120/240 3ph 0480 3W 3ph Other
®-Standard residential loads (Lighting refrigerator dishwasher washer)
Check all that apply A/C ton) Range /Oven Hot Tub
Clothes Dryer fgJ-leating Pumps Hp)
FA-Water Heater Elevator Hp) Other
Total square footage
Voltage
No Load Change
Information form xls
Name
Street:
City State ZIP
Daytime Phone
(if other than above)
Name
Daytime Phone
1 Name
1 Daytime Phone
Name
Daytime Phone
Name
Daytime Phone
Existing
Description of work:
Supporting Documentation
Please provide a copy of the following
*Detailed plot plan (dwg or dxf format mandatory for subdivisions)
*Electrical one -line drawing showing the service entrance panel and location
*Connected load data
*Size and locked rotor ps o all motors over 5,4p/
Applicant's Signature A
,ICHT'\ENGP'>` #Original: ti tior' fu.
Electrical Information Form
Public Works Utilities Department (360) 417 -4700
City Electrical Inspector (360) 417 -4735
3 1 b W I.-elk °E- E 1 -0
I a 14 3 U. l 1 qa C c \-e
P r3 uJ a 83(tt
4l°1 12.4-13 Home,Phone vZ,_, cod
4 7 4 3 1
Title Lau.s+
Company
Company
Company
Aew
❑Multi family residence of units
❑Subdivision of lots
❑General service
Other"
L. evJ 5
1
Date 5 I& "i
MAIL OR DELIVER COMPLETED FORM TO 321 E 5TH STREET PORT ANGELES WA 98362
FAX TO 360- 417 -4711
WS
WF
-vied 1
1 24
Q 0
0
h 9 1
100A 919
-491C-
1
41 -r
.:1 3F SECT C
6 W/3—LBC4
'I
16 J-35
160
17t—
0
0
0
0
461
75
21
RT'
1/0 i?,■LCN 2"PVC
J-20
13 0 ---4
13 1 ,,,,ot,..„.1 11 1..6,
Q. c4
-6 g '3(x2:
7 6 1
350 Tpx 12 X 11
I
1 T____ L.
Villag Gi
2T 1
22
22
23
24
0
0
25
0
0
26
27
695
5
35 0 TPX
31
2/
7
1617
Clallam County Assessor Treasurer Property Details 66741 HOUSING AUTHORIT Page 1 of 3
Clallam County Assessor Treasurer
Property Search Results 66741 HOUSING AUTHORITY OF CLALLAM for Year 2010 2011
Property
Account
Property ID 66741 Legal Description. PENINSULA VILLAGE V15
P6 LOT 9' SURVEY V68
P69
Geographic ID' 0630135700900000 Agent Code
Type Real
Tax Area: 0010 PA 121 PORT ST CNTY H2 L Land Use Code 97
Open Space. N DFL N
Historic Property N Remodel Property N
1 21) Multi Family Redevelopment: N
Location
Address: 1943 VILLAGE CIR
PORT ANGELES WA Mapsco C c; If
Neighborhood: Exempt All Exmpt Reference Map ID'
Neighborhood CD' 50110030
Owner
Name HOUSING AUTHORITY OF CLALLAM Owner ID 31369
Mailing Address: 2603 S FRANCIS ST Ownership 100 0000000000%
PORT ANGELES WA 98362 -6710
F Taxes and Assessments Due
Property Tax Information as of 05/20/2010
Amount Due if Paid on.
i Y_ear; ID Taxing Jurisdiction
2010 48774 ST SCH STATE SCHOOL
Exemptions:
EX
First Second I
i Half Half I
Statement Base Base Base Amount
Due Due Penalty Interest 1 Paid I Due
$0 00 $0 00 $0 00 $0 00 $0 00 $0 00
20 48774 CC -GEN COUNTY $0 00 $0 00 $0 00 $0_00_ _$0 00
2010 48774 _PORT PORT $0 00 4 $0 00 $0 00 $0 00 $0 00 $0 00
1 2010 48774 PORT ANG PORT ANGELES $0 00 $0 00 $0 00 $0 00 $0 00 $0 00
2010 48774 S #121 SCHOOL DISTRICT #121 $0 00 $0 00 $0 00 $0 00 $0 $0 00
12010 48774 NTH OLY LIB NORTH OLYMPIC LIBRARY $0 00 $0 00 $0 00 $0 00 $0 00 $0 00
1 2010 48774 HOSP #2 HOSPITAL #2 $0 00 $0 00 $0 00 $0 00 $0 00 $0 00
2010 48774 WSMET PK DIST WILLIAM SHORE M_ET PARK DIST $0 00 $0 00 $0 00 $0 00 $0 00 $0 00
12010 48774 WEED CONTROL WEED CONTROL $1 63 $0 00 $0 00 $1 63 $0 00
2010 48774 TOTAL. $1.63 $0.00 $0.00 $0.00 $1.63 $0.00
1 2009 667412008 ST SCH STATE SCHOOL $0 00 $0 00 $0 00 $0 00 $0 00 $0 00
2009 667412008 CC -GEN COUNTY $0 00 $0 00 $0 00 $0 00 $0 00 $0 00
2009 667412008 PORT PORT $0 00 $0 00 $0 00 $0 00 $0 00 $0 00
2009 667412008 PORT ANG PORT ANGELES $0 00 _$0 00 $0 00 $0 00 $0 00 $0 00
2009 667412008 SD #121 SCHOOL DISTRICT #121 $0 00 $0 00 $0 00 $0 00 $0 00 $0 00
2009 667412008 NTH OLY LIB NORTH OLYMPIC LIBRARY $0 00 $0 00 $0 00 $0 00 $0 00 $0 00
!2009 667412008 HOSP #2 HOSPITAL #2 $0 00 $0 00 $0 00 $0 00 $0 00 $0 00
1 2009 667412008 FIRE PATROL FIRE PATROL $17 90 $0 00 $0 00 $0 00 $17 90 $0 00
http. /vpn.clallam. net: 8084 propertyaccess /Property.aspx ?cid =0 &year= 2010 &prop_id =66 5/20/2010